WorldWideScience

Sample records for non-conventional power systems

  1. Use of non-conventional energy sources for power generation

    International Nuclear Information System (INIS)

    Umapathaiah, R.; Sharma, N.D.

    1999-01-01

    India being a developing country, cannot afford to meet the power and energy demand only from conventional sources. Power generation can be augmented by using non-conventional energy sources. Sufficient importance must be given for recovery of energy from industrial/urban waste. Solar heating system must replace industrial and domestic sectors. Solar photovoltaic, biogas plant, biomass based gasified system must also be given sufficient place in energy sector. More thrust has to be given for generation of power by using sugar cane which is a perennial source

  2. First Aspect of Conventional Power System Assessment for High Wind Power Plants Penetration

    Directory of Open Access Journals (Sweden)

    A Merzic

    2012-11-01

    Full Text Available Most power systems in underdeveloped and developing countries are based on conventional power plants, mainly "slow-response" thermal power plants and a certain number of hydro power plants; characterized by inflexible generating portfolios and traditionally designed to meet own electricity needs. Taking into account operational capabilities of conventional power systems, their development planning will face problems with integration of notable amounts of installed capacities in wind power plants (WPP. This is what highlights the purpose of this work and in that sense, here, possible variations of simulated output power from WPP in the 10 minute and hourly time interval, which need to be balanced, are investigated, presented and discussed. Comparative calculations for the amount of installed power in WPP that can be integrated into a certain power system, according to available secondary balancing power amounts, in case of concentrated and dispersed future WPP are given. The stated has been done using a part of the power system of Bosnia and Herzegovina. In the considered example, by planned geographically distributed WPP construction, even up to cca. 74% more in installed power of WPP can be integrated into the power system than in case of geographically concentrated WPP construction, for the same available amount of (secondary balancing power. These calculations have shown a significant benefit of planned, geographically distributed WPP construction, as an important recommendation for the development planning of conventional power systems, with limited balancing options. Keywords: balancing reserves,  geographical dispersion, output power  variations

  3. Non conventional energy sources and energy conservation

    International Nuclear Information System (INIS)

    Bueno M, F.

    1995-01-01

    Geographically speaking, Mexico is in an enviable position. Sun, water, biomass and geothermal fields main non conventional energy sources with commercial applications, are presents and in some cases plentiful in national territory. Moreover the coastal tidal power which is in research stage in several countries. Non conventional energy sources are an alternative which allow us to reduce the consumption of hydrocarbons or any other type of primary energetic, are not by oneself choices for the energy conservation, but energy replacements. At the beginning of this year, CONAE created the Direction of Non conventional Energy Sources, which main objective is to promote and impulse programs inclined towards the application of systems based in renewable energy sources. The research centers represent a technological and consultative support for the CONAE. They have an infrastructure developed along several years of continuous work. The non conventional energy sources will be a reality at the same time that their cost be equal or lower than the cost for the traditional generating systems. CONAE (National Commission for Energy Conservation). (Author)

  4. Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems.

    Science.gov (United States)

    An, Jiwoo; Trujillo-Rodríguez, María J; Pino, Verónica; Anderson, Jared L

    2017-06-02

    The development of rapid, convenient, and high throughput sample preparation approaches such as liquid phase microextraction techniques have been continuously developed over the last decade. More recently, significant attention has been given to the replacement of conventional organic solvents used in liquid phase microextraction techniques in order to reduce toxic waste and to improve selectivity and/or extraction efficiency. With these objectives, non-conventional solvents have been explored in liquid phase microextraction and aqueous biphasic systems. The utilized non-conventional solvents include ionic liquids, magnetic ionic liquids, and deep eutectic solvents. They have been widely used as extraction solvents or additives in various liquid phase microextraction modes including dispersive liquid-liquid microextraction, single-drop microextraction, hollow fiber-liquid phase microextraction, as well as in aqueous biphasic systems. This review provides an overview into the use of non-conventional solvents in these microextraction techniques in the past 5 years (2012-2016). Analytical applications of the techniques are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Non-exclusive satellite power system

    Energy Technology Data Exchange (ETDEWEB)

    Drummond, J.E. (Power Conversion Technology, Inc., San Diego, Calif.); Cowhey, P.F. (California, University, La Jolla, Calif.)

    1980-09-01

    A modification of the satellite solar power system employing smaller satellites that are not stationary but move in circular or elliptical orbits of two or three hour periods is discussed. The orbits could be inclined at plus or minus 63.4 deg, 73.1 deg, or 14.3 deg to the equatorial plane. This Interregional or Isoinsolation Power System (IPS) greatly reduces the mass and cost of the antenna needed in the sky and the area required for the rectenna and safety region on the ground (the product of the areas of the antennas and rectennas of the IPS system being between 10 and 20 times lower than that required in the conventional SPS system). International control of IPS through a Solar Satellite Consortium (Solsat) is advocated, patterned after the successful Intelsat consortium, and it is stressed that the system must not be allowed to acquire a military capacity. It is emphasized that the smaller rectennas would not destabilize the ionosphere.

  6. Models for the transient stability of conventional power generating stations connected to low inertia systems

    Science.gov (United States)

    Zarifakis, Marios; Coffey, William T.; Kalmykov, Yuri P.; Titov, Sergei V.

    2017-06-01

    An ever-increasing requirement to integrate greater amounts of electrical energy from renewable sources especially from wind turbines and solar photo-voltaic installations exists and recent experience in the island of Ireland demonstrates that this requirement influences the behaviour of conventional generating stations. One observation is the change in the electrical power output of synchronous generators following a transient disturbance especially their oscillatory behaviour accompanied by similar oscillatory behaviour of the grid frequency, both becoming more pronounced with reducing grid inertia. This behaviour cannot be reproduced with existing mathematical models indicating that an understanding of the behaviour of synchronous generators, subjected to various disturbances especially in a system with low inertia requires a new modelling technique. Thus two models of a generating station based on a double pendulum described by a system of coupled nonlinear differential equations and suitable for analysis of its stability corresponding to infinite or finite grid inertia are presented. Formal analytic solutions of the equations of motion are given and compared with numerical solutions. In particular the new finite grid model will allow one to identify limitations to the operational range of the synchronous generators used in conventional power generation and also to identify limits, such as the allowable Rate of Change of Frequency which is currently set to ± 0.5 Hz/s and is a major factor in describing the volatility of a grid as well as identifying requirements to the total inertia necessary, which is currently provided by conventional power generators only, thus allowing one to maximise the usage of grid connected non-synchronous generators, e.g., wind turbines and solar photo-voltaic installations.

  7. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    power transmission options with HVDC systems are under consideration. In this paper, a comparison between a conventional HVAC transmission system and a HVDC system equipped with modular voltage source converters is provided. The comparison is based on the total energy transmission capability...

  8. Control of non-conventional synchronous motors

    CERN Document Server

    Louis, Jean-Paul

    2013-01-01

    Classical synchronous motors are the most effective device to drive industrial production systems and robots with precision and rapidity. However, numerous applications require efficient controls in non-conventional situations. Firstly, this is the case with synchronous motors supplied by thyristor line-commutated inverters, or with synchronous motors with faults on one or several phases. Secondly, many drive systems use non-conventional motors such as polyphase (more than three phases) synchronous motors, synchronous motors with double excitation, permanent magnet linear synchronous motors,

  9. Probabilistic modeling of wind energy sources integrated in a conventional power system; Modelagem probabilistica de fontes eolicas de energia integradas em sistema de potencia convencional

    Energy Technology Data Exchange (ETDEWEB)

    Dalence, G W.H.

    1990-06-15

    This work describes a model capable of including non-conventional energy sources into a stochastic energy production model for conventional power sources. A wind energy system is initially considered as statistically independent of the hourly demand. The correlation between two wind systems is then considered by means of a joint wind speed distribution. The joint wind system is thereafter submitted to the stochastic energy production model considering independence between demand and wind speed. Finally the correlation wind systems and the hourly demand is studied. (author). 29 figs, 31 tabs

  10. Investigating power control in autonomous power systems with increasing wind power penetration

    Energy Technology Data Exchange (ETDEWEB)

    Margaris, Ioannis D. [National Technical Univ. of Athens (Greece). Electric Energy Systems Lab.; Hansen, Anca D.; Sorensen, Poul [Risoe National Laboratory, Roskilde (Denmark). Wind Energy Dept.; Hatziargyriou, Nikos D. [National Technical Univ. of Athens (Greece). Electric Energy Systems Lab.; Public Power Corporation S.A., Athens (Greece)

    2009-07-01

    Increasing levels of wind penetration in autonomous power systems has set intensively high standards with respect to wind turbine technology during the last years. Special features of non-interconnected power systems make security issues rather critical, as the operation of large wind farms like conventional power plants is becoming a necessity. This paper includes the study case of Rhodos island, in Greece, where rapidly increasing wind penetration has started to impose serious security issues for the immediate future. The scenarios studied here correspond to reference year of study 2012 and include wind farms with three different wind turbine technologies - namely Doubly Fed Induction Generator (DFIG), Permanent Magnet Synchronous Generator (PMSG) and Active Stall Induction Generator (ASIG) based wind turbines. Aggregated models of the wind farms are being used and results for different load cases are being analyzed and discussed. The ability of wind farms to assist in some of the power system control services traditionally carried out by conventional synchronous generation is being investigated and discussed. The power grid of the island, including speed governors and automatic voltage regulators, is simulated in the dedicated power system simulation program Power Factory from DIgSILENT. (orig.)

  11. Dynamic security issues in autonomous power systems with increasing wind power penetration

    DEFF Research Database (Denmark)

    Margaris, I.D.; Hansen, Anca Daniela; Sørensen, Poul Ejnar

    2011-01-01

    Asynchronous Generator (DFAG) and Permanent Magnet Synchronous Generator (PMSG) – are applied and issues regarding interaction with the power system are investigated. This paper provides conclusions about the dynamic security of non-interconnected power systems with high wind power penetration based...... on a complete model representation of the individual components of the system; three different types of conventional generators are included in the model, while the protection system is also incorporated. The load shedding following faults is finally discussed....

  12. 2015 Plan. Project 7: the environmental issue and the electrical sector. The options of electrical power supply and their socio-environmental implications: sources/conventional and non-conventional technologies of generation

    International Nuclear Information System (INIS)

    1992-10-01

    The socio-environmental impacts caused by the uses of conventional sources (hydraulic, mineral coal, nuclear, petroleum by-products and natural gas) and non-conventional (biomass, solar, eolic, ocean and organic wastes) in electric power generation are presented. The main topics that integrate the environmental schedule in the last years are described, including some considerations about environmental legislation and atmospheric alterations. The reserves for each source are also cited. (C.G.C.)

  13. Similarities and differences between conventional power and nuclear power

    International Nuclear Information System (INIS)

    Wang Yingrong

    2011-01-01

    As the implementation of the national guideline of 'proactively promoting nuclear power development', especially after China decided in 2006 to introduce Westinghouse's AP1000 technology, some of the power groups specialized in conventional power generation, have been participating in the preliminary work and construction of nuclear power projects in certain degrees. Meanwhile, such traditional nuclear power corporations as China National Nuclear Corporation (CNNC) and China Guangdong Nuclear Power Corporation (CGNPC) have also employed some employees with conventional power generation experience. How can these employees who have long been engaged in conventional power generation successfully adapt to the new work pattern, ideology, knowledge, thinking mode and proficiency of nuclear power, so that they can fit in with the work requirements of nuclear power and become qualified as soon as possible? By analyzing the technological, managerial and cultural features of nuclear power, as well as some issues to be kept in mind when engaged in nuclear power, this paper intends to make some contribution to the nuclear power development in the specific period. (author)

  14. The economics of developing non-conventional reserves

    International Nuclear Information System (INIS)

    Kuuskraa, V.A.

    1997-01-01

    A fact-based perspective on the economics of non-conventional natural gas reserves such as coalbed methane, gas shales and tight gas was presented. Traditionally, tax credits stimulate the development of non-conventional gas. Although tax credits for non-conventional gas development stopped at the end of 1992, because of improved technologies, improved finding rates and well productivities, non-conventional reserves continue to play a major role in the U.S. gas drilling development. Non-conventional reserves account for three out of five gas wells drilled in the U.S. The non-conventional gas industry competes directly with the conventional natural gas industry. This paper examined how well non-conventional gas compares to the current replacement costs of conventional natural gas. Investment costs for a non-conventional operation were studied, illustrated by an overview of the costs and economics of non-conventional reserves in the San Juan coal basin, the Piceance tight gas basin and the Michigan and Ft. Worth gas shales basins. 9 tabs

  15. Wind power plant system services

    DEFF Research Database (Denmark)

    Basit, Abdul; Altin, Müfit

    Traditionally, conventional power plants have the task to support the power system, by supplying power balancing services. These services are required by the power system operators in order to secure a safe and reliable operation of the power system. However, as in the future the wind power...... is going more and more to replace conventional power plants, the sources of conventional reserve available to the system will be reduced and fewer conventional plants will be available on-line to share the regulation burden. The reliable operation of highly wind power integrated power system might...... then beat risk unless the wind power plants (WPPs) are able to support and participate in power balancing services. The objective of this PhD project is to develop and analyse control strategies which can increase the WPPs capability to provide system services, such as active power balancing control...

  16. Non-conventional screening of the Coulomb interaction in low-dimensional and finite-size systems

    NARCIS (Netherlands)

    van den Brink, J.; Sawatzky, G.A.

    2000-01-01

    We study the screening of the Coulomb interaction in non-polar systems by polarizable atoms. We show that in low dimensions and small finite-size systems this screening deviates strongly from that conventionally assumed. In fact in one dimension the short-range interaction is strongly screened and

  17. Stability analysis of a power system made up of an intermittent renewable energy source directly tied to a conventional rotating power generator

    International Nuclear Information System (INIS)

    Coiante, D.

    1997-02-01

    A simple power system made up of a conventional rotating power generator in direct connection to an intermittent renewable energy source (with energy or photovoltaic) is modelled on the base of respective functional schemes. The relative variations of the voltage frequency are calculated as an output to an abrupt variation of intermittent tied power and in function of electro-mechanical parameters of the rotating generator (dumping coefficient and inertial rotor coefficient). The stability conditions and the tolerance allowed on the frequency variations are considered in relation to toad service requires. As a consequence, the maximum intermittent power amount, which can be accepted in direct connection, is obtained. For usual conventional rotating machines, the resulting limit is placed in the range of (12-19)% of nominal capacity of power generator

  18. Mini Solar and Sea Current Power Generation System

    Science.gov (United States)

    Almenhali, Abdulrahman; Alshamsi, Hatem; Aljunaibi, Yaser; Almussabi, Dheyab; Alshehhi, Ahmed; Hilal, Hassan Bu

    2017-07-01

    The power demand in United Arab Emirates is increased so that there is a consistent power cut in our region. This is because of high power consumption by factories and also due to less availability of conventional energy resources. Electricity is most needed facility for the human being. All the conventional energy resources are depleting day by day. So we have to shift from conventional to non-conventional energy resources. In this the combination of two energy resources is takes place i.e. wind and solar energy. This process reviles the sustainable energy resources without damaging the nature. We can give uninterrupted power by using hybrid energy system. Basically this system involves the integration of two energy system that will give continuous power. Solar panels are used for converting solar energy and wind turbines are used for converting wind energy into electricity. This electrical power can utilize for various purpose. Generation of electricity will be takes place at affordable cost. This paper deals with the generation of electricity by using two sources combine which leads to generate electricity with affordable cost without damaging the nature balance. The purpose of this project was to design a portable and low cost power system that combines both sea current electric turbine and solar electric technologies. This system will be designed in efforts to develop a power solution for remote locations or use it as another source of green power.

  19. Synthetic Biology and Metabolic Engineering Approaches and Its Impact on Non-Conventional Yeast and Biofuel Production

    Energy Technology Data Exchange (ETDEWEB)

    Madhavan, Aravind [Biotechnology Division, National Institute for Interdisciplinary Science and Technology, Council of Scientific and Industrial Research, Trivandrum (India); Rajiv Gandhi Centre for Biotechnology, Trivandrum (India); Jose, Anju Alphonsa; Binod, Parameswaran; Sindhu, Raveendran, E-mail: sindhurgcb@gmail.com; Sukumaran, Rajeev K. [Biotechnology Division, National Institute for Interdisciplinary Science and Technology, Council of Scientific and Industrial Research, Trivandrum (India); Pandey, Ashok [Biotechnology Division, National Institute for Interdisciplinary Science and Technology, Council of Scientific and Industrial Research, Trivandrum (India); Center for Innovative and Applied Bioprocessing, Mohali, Punjab (India); Castro, Galliano Eulogio [Dpt. Ingeniería Química, Ambiental y de los Materiales Edificio, Universidad de Jaén, Jaén (Spain)

    2017-04-25

    The increasing fossil fuel scarcity has led to an urgent need to develop alternative fuels. Currently microorganisms have been extensively used for the production of first-generation biofuels from lignocellulosic biomass. Yeast is the efficient producer of bioethanol among all existing biofuels option. Tools of synthetic biology have revolutionized the field of microbial cell factories especially in the case of ethanol and fatty acid production. Most of the synthetic biology tools have been developed for the industrial workhorse Saccharomyces cerevisiae. The non-conventional yeast systems have several beneficial traits like ethanol tolerance, thermotolerance, inhibitor tolerance, genetic diversity, etc., and synthetic biology have the power to expand these traits. Currently, synthetic biology is slowly widening to the non-conventional yeasts like Hansenula polymorpha, Kluyveromyces lactis, Pichia pastoris, and Yarrowia lipolytica. Herein, we review the basic synthetic biology tools that can apply to non-conventional yeasts. Furthermore, we discuss the recent advances employed to develop efficient biofuel-producing non-conventional yeast strains by metabolic engineering and synthetic biology with recent examples. Looking forward, future synthetic engineering tools’ development and application should focus on unexplored non-conventional yeast species.

  20. Synthetic Biology and Metabolic Engineering Approaches and Its Impact on Non-Conventional Yeast and Biofuel Production

    Directory of Open Access Journals (Sweden)

    Raveendran Sindhu

    2017-04-01

    Full Text Available The increasing fossil fuel scarcity has led to an urgent need to develop alternative fuels. Currently microorganisms have been extensively used for the production of first-generation biofuels from lignocellulosic biomass. Yeast is the efficient producer of bioethanol among all existing biofuels option. Tools of synthetic biology have revolutionized the field of microbial cell factories especially in the case of ethanol and fatty acid production. Most of the synthetic biology tools have been developed for the industrial workhorse Saccharomyces cerevisiae. The non-conventional yeast systems have several beneficial traits like ethanol tolerance, thermotolerance, inhibitor tolerance, genetic diversity, etc., and synthetic biology have the power to expand these traits. Currently, synthetic biology is slowly widening to the non-conventional yeasts like Hansenula polymorpha, Kluyveromyces lactis, Pichia pastoris, and Yarrowia lipolytica. Herein, we review the basic synthetic biology tools that can apply to non-conventional yeasts. Furthermore, we discuss the recent advances employed to develop efficient biofuel-producing non-conventional yeast strains by metabolic engineering and synthetic biology with recent examples. Looking forward, future synthetic engineering tools’ development and application should focus on unexplored non-conventional yeast species.

  1. Synthetic Biology and Metabolic Engineering Approaches and Its Impact on Non-Conventional Yeast and Biofuel Production

    International Nuclear Information System (INIS)

    Madhavan, Aravind; Jose, Anju Alphonsa; Binod, Parameswaran; Sindhu, Raveendran; Sukumaran, Rajeev K.; Pandey, Ashok; Castro, Galliano Eulogio

    2017-01-01

    The increasing fossil fuel scarcity has led to an urgent need to develop alternative fuels. Currently microorganisms have been extensively used for the production of first-generation biofuels from lignocellulosic biomass. Yeast is the efficient producer of bioethanol among all existing biofuels option. Tools of synthetic biology have revolutionized the field of microbial cell factories especially in the case of ethanol and fatty acid production. Most of the synthetic biology tools have been developed for the industrial workhorse Saccharomyces cerevisiae. The non-conventional yeast systems have several beneficial traits like ethanol tolerance, thermotolerance, inhibitor tolerance, genetic diversity, etc., and synthetic biology have the power to expand these traits. Currently, synthetic biology is slowly widening to the non-conventional yeasts like Hansenula polymorpha, Kluyveromyces lactis, Pichia pastoris, and Yarrowia lipolytica. Herein, we review the basic synthetic biology tools that can apply to non-conventional yeasts. Furthermore, we discuss the recent advances employed to develop efficient biofuel-producing non-conventional yeast strains by metabolic engineering and synthetic biology with recent examples. Looking forward, future synthetic engineering tools’ development and application should focus on unexplored non-conventional yeast species.

  2. Do Farmers Using Conventional and Non-Conventional Systems of Agriculture Have Different Perceptions of the Diversity of Wild Birds? Implications for Conservation

    Science.gov (United States)

    de Andrade, Luciano Pires; Muniz, Lauana Souza; Telino-Júnior, Wallace Rodrigues; Albuquerque, Ulysses Paulino; Lyra-Neves, Rachel Maria

    2016-01-01

    Farmers’ perceptions of birds’ interactions with agricultural production systems are fundamental to species conservation efforts. In the present study, we evaluated the perceptions of birds held by farmers who engage in conventional and non-conventional agricultural production processes and the implications of potential differences in these perceptions on species conservation. To accomplish this, data were collected using questionnaires, semi-structured interviews, and other complementary sources of information gathered from 191 farmers in northeastern Brazil. Although some similarities were identified among the farmers in their perceptions and local ecological knowledge (LEK) of birds, differences existed between the conventional and non-conventional farmers in their attitudes toward, conflicts with, and usage of bird species. Compared to the conventional farmers, the non-conventional farmers could identify more bird species, possessed more favorable attitudes toward birds, and engaged in practices more beneficial to the conservation of avifauna. The perceptions that were identified were related to the type of agriculture practiced, and such perceptions may affect the conservation of bird species. Therefore, the adoption of certain agricultural practices has important implications for conservation. Our results indicate the need for investment in public policies, programs and actions that account for farmers’ knowledge and perceptions. Such investments will contribute to the development and adoption of practices supporting wild bird conservation in agricultural areas. PMID:27243222

  3. Do Farmers Using Conventional and Non-Conventional Systems of Agriculture Have Different Perceptions of the Diversity of Wild Birds? Implications for Conservation.

    Science.gov (United States)

    Silva-Andrade, Horasa Lima; de Andrade, Luciano Pires; Muniz, Lauana Souza; Telino-Júnior, Wallace Rodrigues; Albuquerque, Ulysses Paulino; Lyra-Neves, Rachel Maria

    2016-01-01

    Farmers' perceptions of birds' interactions with agricultural production systems are fundamental to species conservation efforts. In the present study, we evaluated the perceptions of birds held by farmers who engage in conventional and non-conventional agricultural production processes and the implications of potential differences in these perceptions on species conservation. To accomplish this, data were collected using questionnaires, semi-structured interviews, and other complementary sources of information gathered from 191 farmers in northeastern Brazil. Although some similarities were identified among the farmers in their perceptions and local ecological knowledge (LEK) of birds, differences existed between the conventional and non-conventional farmers in their attitudes toward, conflicts with, and usage of bird species. Compared to the conventional farmers, the non-conventional farmers could identify more bird species, possessed more favorable attitudes toward birds, and engaged in practices more beneficial to the conservation of avifauna. The perceptions that were identified were related to the type of agriculture practiced, and such perceptions may affect the conservation of bird species. Therefore, the adoption of certain agricultural practices has important implications for conservation. Our results indicate the need for investment in public policies, programs and actions that account for farmers' knowledge and perceptions. Such investments will contribute to the development and adoption of practices supporting wild bird conservation in agricultural areas.

  4. Do Farmers Using Conventional and Non-Conventional Systems of Agriculture Have Different Perceptions of the Diversity of Wild Birds? Implications for Conservation.

    Directory of Open Access Journals (Sweden)

    Horasa Lima Silva-Andrade

    Full Text Available Farmers' perceptions of birds' interactions with agricultural production systems are fundamental to species conservation efforts. In the present study, we evaluated the perceptions of birds held by farmers who engage in conventional and non-conventional agricultural production processes and the implications of potential differences in these perceptions on species conservation. To accomplish this, data were collected using questionnaires, semi-structured interviews, and other complementary sources of information gathered from 191 farmers in northeastern Brazil. Although some similarities were identified among the farmers in their perceptions and local ecological knowledge (LEK of birds, differences existed between the conventional and non-conventional farmers in their attitudes toward, conflicts with, and usage of bird species. Compared to the conventional farmers, the non-conventional farmers could identify more bird species, possessed more favorable attitudes toward birds, and engaged in practices more beneficial to the conservation of avifauna. The perceptions that were identified were related to the type of agriculture practiced, and such perceptions may affect the conservation of bird species. Therefore, the adoption of certain agricultural practices has important implications for conservation. Our results indicate the need for investment in public policies, programs and actions that account for farmers' knowledge and perceptions. Such investments will contribute to the development and adoption of practices supporting wild bird conservation in agricultural areas.

  5. Non deterministic finite automata for power systems fault diagnostics

    Directory of Open Access Journals (Sweden)

    LINDEN, R.

    2009-06-01

    Full Text Available This paper introduces an application based on finite non-deterministic automata for power systems diagnosis. Automata for the simpler faults are presented and the proposed system is compared with an established expert system.

  6. Conventional and Non-Conventional Yeasts in Beer Production

    Directory of Open Access Journals (Sweden)

    Angela Capece

    2018-06-01

    Full Text Available The quality of beer relies on the activity of fermenting yeasts, not only for their good fermentation yield-efficiency, but also for their influence on beer aroma, since most of the aromatic compounds are intermediate metabolites and by-products of yeast metabolism. Beer production is a traditional process, in which Saccharomyces is the sole microbial component, and any deviation is considered a flaw. However, nowadays the brewing sector is faced with an increasing demand for innovative products, and it is diffusing the use of uncharacterized autochthonous starter cultures, spontaneous fermentation, or non-Saccharomyces starters, which leads to the production of distinctive and unusual products. Attempts to obtain products with more complex sensory characteristics have led one to prospect for non-conventional yeasts, i.e., non-Saccharomyces yeasts. These generally are characterized by low fermentation yields and are more sensitive to ethanol stress, but they provide a distinctive aroma and flavor. Furthermore, non-conventional yeasts can be used for the production of low-alcohol/non-alcoholic and light beers. This review aims to present the main findings about the role of traditional and non-conventional yeasts in brewing, demonstrating the wide choice of available yeasts, which represents a new biotechnological approach with which to target the characteristics of beer and to produce different or even totally new beer styles.

  7. Non-conventional energy and propulsion methods

    International Nuclear Information System (INIS)

    Valone, T.

    1991-01-01

    From the disaster of the Space Shuttle, Challenger, to the Kuwaiti oil well fires, we are reminded constantly of our dependence on dangerous, combustible fuels for energy and propulsion. Over the past ten years, there has been a considerable production of new and exciting inventions which defy conventional analysis. The term non-conventional was coined in 1980 by a Canadian engineer to designate a separate technical discipline for this type of endeavor. Since then, several conferences have been devoted solely to these inventions. Integrity Research Corp., an affiliate of the Institute, has made an effort to investigate each viable product, develop business plans for several to facilitate development and marketing, and in some cases, assign an engineering student intern to building a working prototype. Each inventor discussed in this presentation has produced a unique device for free energy generation or highly efficient force production. Included in this paper is also a short summary for non-specialists explaining the physics of free energy generation along with a working definition. The main topics of discussion include: space power, inertial propulsion, kinetobaric force, magnetic motors, thermal fluctuations, over-unity hat pumps, ambient temperature superconductivity and nuclear battery

  8. System design methodology of non-fossil fuel fired power plants

    International Nuclear Information System (INIS)

    Mohamed, J.A.; Guven, H.M.

    1992-01-01

    In most thermal system designs, economic and thermodynamic aspects of the design are not studied simultaneously early on in the design process. As a result, the economic ramification of thermodynamic changes to the system configuration, and vice versa, are not immediately apparent to the designer or the performance, involving both thermal and economic aspects of the plant. In this study, a rational approach is presented to formalize the design process of small power plants, typically, burning non-conventional fuel sources such as wood residues, tires, biofuels, etc. The method presented in this paper allows for handling of process information, both qualitative and quantitative, to enable the designer to change his design in an optimal manner. A two-level design structure (macro-level and micro-level), is introduced to enable the designer to adapt his design in an efficient manner to the available (or required) technology-level, type of application, economic factors, O and M requirements, etc. At the macro-level of design, economic feasibility (business) decisions are made, while at the micro-level of design, technical feasibility (engineering) decisions are made

  9. Thermo economic comparison of conventional micro combined heat and power systems with solid oxide fuel cell systems for small scale applications

    DEFF Research Database (Denmark)

    Batens, Ellen; Cuellar, Rafael; Marissal, Matthieu

    2013-01-01

    out a thermo economic comparison of a conventional micro combined heat and power systems with solid oxide fuel cell systems. A model to estimate the savings and cost targets for solid oxide fuel cell systems is presented. A comparison between fuel cell technologies in the danish market with “state......Fuel cells have the potential to reduce domestic energy consumption by providing both heat and electricity at the point of use. However, the cost of installing the fuel cell must be sufficiently competitive to be recovered by the savings made over its lifetime. The goal of this paper is to carry...... of the art” traditional heat and power generation technologies currently used in Denmark is considered. The conventional method of covering electrical, heating (e.g. hot water) and cooling (e.g. space cooling) load demands is by purchasing electricity from the electricity network grid and with a fossil fuel...

  10. Quality assurance system for conventional island erection of Daya Day Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Zhongliang, Shi; Suozhi, Wu; Xiangke, Meng [Shandong Electric Power Construction Corp. Nuclear Power Construction Company (China)

    1994-12-01

    The process concerning the establishment, operation and perfection of Quality Assurance System (QA system) experienced by Shandong Electric Power Construction Corporation, Nuclear Power Construction Company (SEPC-NPCC) during the implementation of Conventional Island Erection (CIE) in Daya Bay Nuclear Power Plant is introduced. Apart from systematic description of the principle for working out QA programme and QA procedures and their main contents, it is also detailed, on a combination of theory with practice basis, how the major departments constituting the QA system such as Quality Assurance, Quality Control, Construction and Administration and Business Departments have made fruitful efforts as per the individual responsibility for ensuring the work quality and having in mind the principles specified by QA programme and the requirements of QA procedures. As a result of the reasonable combination of the 3 crucial points and the 4 essential elements of the QA system, high quality of CI erection has been realized. The importance of quality supervision and management review by the owner and upper levels of authorities for ensuring effective operation of QA system is affirmed. The practical experience of CIE project proves that the strict inspection/surveillance on all activities and service affecting quality carried out by QA Department independent of project management and QC Dept, independent of construction management are of quite importance for ensuring the project quality. (4 tabs.).

  11. Quality assurance system for conventional island erection of Daya Day Nuclear Power Plant

    International Nuclear Information System (INIS)

    Shi Zhongliang; Wu Suozhi; Meng Xiangke

    1994-12-01

    The process concerning the establishment, operation and perfection of Quality Assurance System (QA system) experienced by Shandong Electric Power Construction Corporation, Nuclear Power Construction Company (SEPC-NPCC) during the implementation of Conventional Island Erection (CIE) in Daya Bay Nuclear Power Plant is introduced. Apart from systematic description of the principle for working out QA programme and QA procedures and their main contents, it is also detailed, on a combination of theory with practice basis, how the major departments constituting the QA system such as Quality Assurance, Quality Control, Construction and Administration and Business Departments have made fruitful efforts as per the individual responsibility for ensuring the work quality and having in mind the principles specified by QA programme and the requirements of QA procedures. As a result of the reasonable combination of the 3 crucial points and the 4 essential elements of the QA system, high quality of CI erection has been realized. The importance of quality supervision and management review by the owner and upper levels of authorities for ensuring effective operation of QA system is affirmed. The practical experience of CIE project proves that the strict inspection/surveillance on all activities and service affecting quality carried out by QA Department independent of project management and QC Dept, independent of construction management are of quite importance for ensuring the project quality. (4 tabs.)

  12. Power system stabilizer control for wind power to enhance power system stability

    OpenAIRE

    Domínguez García, José Luís; Gomis Bellmunt, Oriol; Bianchi, Fernando Daniel; Sumper, Andreas

    2011-01-01

    The paper presents a small signal stability analysis for power systems with wind farm interaction. Power systems have damping oscillation modes that can be excited by disturbance or fault in the grid. The power converters of the wind farms can be used to reduce these oscillations and make the system more stable. These ideas are explored to design a power system stabilized (PSS) for a network with conventional generators and a wind farm in order to increase the damping of the oscillation...

  13. Non-contact magnetic coupled power and data transferring system for an electric vehicle

    International Nuclear Information System (INIS)

    Matsuda, Y.; Sakamoto, H.

    2007-01-01

    We have developed a system which transmits electric power and communication data simultaneously in a non-contact method using a magnetic coupling coil. Already, we are developing the fundamental technology of a non-contact charging system, and this is applied in electric shavers, electric toothbrushes, etc. Moreover, basic experiments are being conducted for applying this non-contact charging system to electric equipments such as an electric vehicle (EV), which is a zero emission vehicle and environmentally excellent and will be the transportation means of the next generation. The technology can also be applied in other electronic equipment, etc. However, since the power supply route for these individual devices is independent, the supply system is complicated. EV also has to perform the transmission of electric power and the transmission of information (data), such as the amount of the charge, in a separate system, and thus is quite complicated. In this study, by performing simultaneously the transmission of electric power and information (data) using magnetic coupling technology in which it does not contact, the basic experiment aimed at attaining and making unification of a system simple was conducted, and the following good results were obtained: (1) Electric power required for load can be transmitted easily by non-contact. (2) A signal can easily be transmitted bidirectionally by non-contact. (3) This system is reliable, and is widely applicable

  14. Dynamic Reactive Power Compensation of Large Scale Wind Integrated Power System

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Chen, Zhe; Thøgersen, Paul

    2015-01-01

    wind turbines especially wind farms with additional grid support functionalities like dynamic support (e,g dynamic reactive power support etc.) and ii) refurbishment of existing conventional central power plants to synchronous condensers could be one of the efficient, reliable and cost effective option......Due to progressive displacement of conventional power plants by wind turbines, dynamic security of large scale wind integrated power systems gets significantly compromised. In this paper we first highlight the importance of dynamic reactive power support/voltage security in large scale wind...... integrated power systems with least presence of conventional power plants. Then we propose a mixed integer dynamic optimization based method for optimal dynamic reactive power allocation in large scale wind integrated power systems. One of the important aspects of the proposed methodology is that unlike...

  15. Development and advances in conventional high power RF systems

    International Nuclear Information System (INIS)

    Wilson, P.B.

    1995-06-01

    The development of rf systems capable of producing high peak power (hundreds of megawatts) at relatively short pulse lengths (0.1--5 microseconds) is currently being driven mainly by the requirements of future high energy linear colliders, although there may be applications to industrial, medical and research linacs as well. The production of high peak power rf typically involves four basic elements: a power supply to convert ac from the ''wall plug'' to dc; a modulator, or some sort of switching element, to produce pulsed dc power; an rf source to convert the pulsed dc to pulsed rf power; and possibly an rf pulse compression system to further enhance the peak rf power. Each element in this rf chain from wall plug to accelerating structure must perform with high efficiency in a linear collider application, such that the overall system efficiency is 30% or more. Basic design concepts are discussed for klystrons, modulators and rf pulse compression systems, and their present design status is summarized for applications to proposed linear colliders

  16. Environmental impact of non-conventional energy sources

    International Nuclear Information System (INIS)

    Abbasi, S.A.; Abbasi, Naseema; Nipaney, P.C.; Ramasamy, E.V.

    1995-01-01

    Whereas the global attention has always been focused on the adverse environmental impacts of conventional energy sources, only a few studies have been conducted on the clean environment image of the non-conventional energy sources, particularly the renewable ones. The question whether the non-conventional sources are really as benign as they are made out to be is addressed in the present paper in the background of a classical paradigm developed by Lovin which had postulated the hard (malignant) and soft (benign) energy concepts in the first place. It then assesses the likely environmental impacts of several major non-conventional energy sources and comes up with the note of caution that in many cases the adverse impacts may not be insubstantial; indeed in some cases they can be as strongly negative as the impacts of the conventional energy sources. (author). 31 refs

  17. Performance analysis of conventional PSS and fuzzy controller for damping power system oscillations

    OpenAIRE

    Banna, Hasan UI; Luna Alloza, Álvaro; Rodríguez Cortés, Pedro; Cabrera Tobar, Ana; Ghorbani, Hamidreza; Ying, Shaoqing

    2014-01-01

    Electro-mechanical oscillations are produced, in the machines of an interconnected power network, followed by a disturbance or due to high power transfer through weak tie lines. These oscillations should be damped as quickly as possible to ensure the reliable and stable operation of the network. To damp these oscillations different controllers, based on local or wide area signals, have been the subject of many papers. This paper presents the analysis of the performance of Conventional Power S...

  18. Cycling of conventional power plants: Technical limits and actual costs

    International Nuclear Information System (INIS)

    Van den Bergh, Kenneth; Delarue, Erik

    2015-01-01

    Highlights: • Literature reports a wide range of cycling parameters (technical and cost-related). • The impact of different cycling parameters is assessed. • The German 2013 system is studied as a case study. • Even for stringent parameters, the dynamic limit of the portfolio is not reached. • Cycling costs can be reduced with 40% when taken into account in the scheduling. - Abstract: Cycling of conventional generation units is an important source of operational flexibility in the electricity generation system. Cycling is changing the power output of conventional units by means of ramping and switching (starting up and shutting down). In the literature, a wide range of technical and cost-related cycling parameters can be found. Different studies allocate different cycling parameters to similar generation units. This paper assesses the impact of different cycling parameters allocated to a conventional generation portfolio. Both the technical limitations of power plants and all costs related to cycling are considered. The results presented in this paper follow from a unit commitment model, used for a case study based on the German 2013 system. The conventional generation portfolio has to deliver different residual load time series, corresponding to different levels of renewables penetration. The study shows, under the assumptions made, that although the dynamic limits of some units are reached, the limits of the conventional generation portfolio as a whole are not reached, even if stringent dynamic parameters are assigned to the generation portfolio and a highly variable residual load is imposed to the system. The study shows also the importance of including full cycling costs in the unit commitment scheduling. The cycling cost can be reduced by up to 40% when fully taken into account

  19. Wind farm - A power source in future power systems

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede

    2009-01-01

    wind turbines and wind farms, and then introduces the wind power development and wind farms. An optimization platform for designing electrical systems of offshore wind farms is briefed. The major issues related to the grid connection requirements and the operation of wind turbines/farms in power......The paper describes modern wind power systems, introduces the issues of large penetration of wind power into power systems, and discusses the possible methods of making wind turbines/farms act as a power source, like conventional power plants in power systems. Firstly, the paper describes modern...... systems are illustrated....

  20. Power Quality in DC Power Distribution Systems and Microgrids

    Directory of Open Access Journals (Sweden)

    Stephen Whaite

    2015-05-01

    Full Text Available This review paper discusses power quality considerations for direct current (DC electric power distribution systems, particularly DC microgrids. First, four selected sample DC architectures are discussed to provide motivation for the consideration of power quality in DC systems. Second, a brief overview of power quality challenges in conventional alternating current (AC distribution systems is given to establish the field of power quality. Finally, a survey of literature addressing power quality issues in DC systems is presented, and necessary power quality considerations in DC distribution system design and operation are discussed.

  1. Modeling on a PWR power conversion system with system program

    International Nuclear Information System (INIS)

    Gao Rui; Yang Yanhua; Lin Meng

    2007-01-01

    Based on the power conversion system of nuclear and conventional islands of Daya Bay Power Station, this paper models the thermal-hydraulic systems of primary and secondary loops for PWR by using the PWR best-estimate program-RELAP5. To simulate the full-scope power conversion system, not only the traditional basic system models of nuclear island, but also the major system models of conventional island are all considered and modeled. A comparison between the calculated results and the actual data of reactor demonstrates a fine match for Daya Bay Nuclear Power Station, and manifests the feasibility in simulating full-scope power conversion system of PWR by RELAP5 at the same time. (authors)

  2. Financing options to develop non-conventional reserves

    International Nuclear Information System (INIS)

    Tricoli, C.

    1997-01-01

    The economics of non-conventional natural gas reserves such as coalbed methane, gas shales and tight gas were discussed, with special reference to financing options to develop such reserves. Before 1992, tax credits were used to stimulate the development of non-conventional gas. The requirements for section 29 tax credits, the objectives of investors and producers, and the methods used to monetize section 29 tax credits, such as public royalty trusts, partnership structures, and up-front payment mechanisms were described. The capital gains implications of gas sales were also reviewed. It was noted that in the absence of tax credits, financing the development of non-conventional reserves must undergo the same economic scrutiny as any other oil and gas project

  3. Extraction of kiwi seed oil: Soxhlet versus four different non-conventional techniques.

    Science.gov (United States)

    Cravotto, Giancarlo; Bicchi, Carlo; Mantegna, Stefano; Binello, Arianna; Tomao, Valerie; Chemat, Farid

    2011-06-01

    Kiwi seed oil has a nutritionally interesting fatty acid profile, but a rather low oxidative stability, which requires careful extraction procedures and adequate packaging and storage. For these reasons and with the aim to achieve process intensification with shorter extraction time, lower energy consumption and higher yields, four different non-conventional techniques were experimented. Kiwi seeds were extracted in hexane using classic Soxhlet as well as under power ultrasound (US), microwaves (MWs; closed vessel) and MW-integrated Soxhlet. Supercritical CO₂ was also employed and compared to the other techniques in term of yield, extraction time, fatty acid profiles and organoleptic properties. All these non-conventional techniques are fast, effective and safe. A sensory evaluation test showed the presence of off-flavours in oil samples extracted by Soxhlet and US, an indicator of partial degradation.

  4. Intelligent Maximum Power Point Tracking Using Fuzzy Logic for Solar Photovoltaic Systems Under Non-Uniform Irradiation Conditions

    OpenAIRE

    P. Selvam; S. Senthil Kumar

    2016-01-01

    Maximum Power Point Tracking (MPPT) has played a vital role to enhance the efficiency of solar photovoltaic (PV) power generation under varying atmospheric temperature and solar irradiation. However, it is hard to track the maximum power point using conventional linear controllers due to the natural inheritance of nonlinear I-V and P-V characteristics of solar PV systems. Fuzzy Logic Controller (FLC) is suitable for nonlinear system control applications and eliminating oscillations, circuit c...

  5. Vachellia karroo leaf meal: a promising non-conventional feed ...

    African Journals Online (AJOL)

    Vachellia karroo leaf meal: a promising non-conventional feed resource for improving goat production in low-input farming systems of Southern Africa. ... Vachellia karroo possesses desirable fatty acid profiles, and high protein and mineral contents that can improve animal performance. Presently, the use of V. karroo for ...

  6. Emergency power systems at nuclear power plants

    International Nuclear Information System (INIS)

    1982-01-01

    This Guide applies to nuclear power plants for which the total power supply comprises normal power supply (which is electric) and emergency power supply (which may be electric or a combination of electric and non-electric). In its present form the Guide provides general guidance for all types of emergency power systems (EPS) - electric and non-electric, and specific guidance (see Appendix A) on the design principles and the features of the emergency electric power system (EEPS). Future editions will include a second appendix giving specific guidance on non-electric power systems. Section 3 of this Safety Guide covers information on considerations that should be taken into account relative to the electric grid, the transmission lines, the on-site electrical supply system, and other alternative power sources, in order to provide high overall reliability of the power supply to the EPS. Since the nuclear power plant operator does not usually control off-site facilities, the discussion of methods of improving off-site reliability does not include requirements for facilities not under the operator's control. Sections 4 to 11 of this Guide provide information, recommendations and requirements that would apply to any emergency power system, be it electric or non-electric

  7. Bioenergy conversion and storage systems: from conventional electrochemical cells to hybrid bioelectronic devices

    DEFF Research Database (Denmark)

    Pankratov, Dmitrii; Chi, Qijin

    2017-01-01

    The rapid development and popularization of wearable and implantable self-sustainable electronics has increasingly demanded new-generation miniature and biocompatible power systems that can function under near-neutral pH solution and ambient conditions. Towards this end, enzymatic fuel cells (EFCs......) using biocatalysts can offer an effective alternative to conventional batteries or fuel cells attributed to high biocatalytic activity, substrate specified selectivity, and non-toxic end products with ecofriendly impacts. Newly emerging photobioelectrochemical cells (PBCs), exploiting photosynthetic...

  8. Are nuclear ships environmentally safer than conventionally powered ships

    International Nuclear Information System (INIS)

    Bone, C.A.; Molgaard, C.A.; Helmkamp, J.C.; Golbeck, A.L.

    1988-01-01

    An epidemiologic analysis was conducted to determine if risk of hospitalization varied by age, ship type, or occupation between nuclear and conventional powered ship crews in the U.S. Navy. Study cohorts consisted of all male enlisted personnel who served exclusively aboard conventional or nuclear powered aircraft carriers and cruisers during the years 1975-1979; cases were those men hospitalized during this period (N = 48,242). Conventional ship personnel showed significantly elevated rates of injury and disease when compared to nuclear ship personnel. The largest relative risks by age occurred for conventional ship crewmen less than 30 years old. Seaman, logistics (supply), and healthcare personnel serving aboard conventional ships comprised the occupational groups exhibiting the highest hospitalization rate differentials. The results strongly suggest that nuclear ships provide a healthier, safer working and living environment than conventional ships

  9. Outage Performance of Hybrid FSO/RF System with Low-Complexity Power Adaptation

    KAUST Repository

    Rakia, Tamer

    2016-02-26

    Hybrid free-space optical (FSO) / radio-frequency (RF) systems have emerged as a promising solution for high data- rate wireless communication systems. We consider truncated channel inversion based power adaptation strategy for coherent and non- coherent hybrid FSO/RF systems, employing an adaptive combining scheme. Specifically, we activate the RF link along with the FSO link when FSO link quality is unacceptable, and adaptively set RF transmission power to ensure constant combined signal-to-noise ratio at receiver terminal. Analytical expressions for the outage probability of the hybrid system with and without power adaptation are derived. Numerical examples show that, the hybrid FSO/RF systems with power adaptation achieve considerable outage performance improvement over conventional hybrid FSO/RF systems without power adaptation. © 2015 IEEE.

  10. One-Dimensional Mass-Spring Chains Supporting Elastic Waves with Non-Conventional Topology

    Directory of Open Access Journals (Sweden)

    2016-04-01

    Full Text Available There are two classes of phononic structures that can support elastic waves with non-conventional topology, namely intrinsic and extrinsic systems. The non-conventional topology of elastic wave results from breaking time reversal symmetry (T-symmetry of wave propagation. In extrinsic systems, energy is injected into the phononic structure to break T-symmetry. In intrinsic systems symmetry is broken through the medium microstructure that may lead to internal resonances. Mass-spring composite structures are introduced as metaphors for more complex phononic crystals with non-conventional topology. The elastic wave equation of motion of an intrinsic phononic structure composed of two coupled one-dimensional (1D harmonic chains can be factored into a Dirac-like equation, leading to antisymmetric modes that have spinor character and therefore non-conventional topology in wave number space. The topology of the elastic waves can be further modified by subjecting phononic structures to externally-induced spatio-temporal modulation of their elastic properties. Such modulations can be actuated through photo-elastic effects, magneto-elastic effects, piezo-electric effects or external mechanical effects. We also uncover an analogy between a combined intrinsic-extrinsic systems composed of a simple one-dimensional harmonic chain coupled to a rigid substrate subjected to a spatio-temporal modulation of the side spring stiffness and the Dirac equation in the presence of an electromagnetic field. The modulation is shown to be able to tune the spinor part of the elastic wave function and therefore its topology. This analogy between classical mechanics and quantum phenomena offers new modalities for developing more complex functions of phononic crystals and acoustic metamaterials.

  11. Nuclear power in Canada

    International Nuclear Information System (INIS)

    1980-01-01

    The Canadian Nuclear Association believes that the CANDU nuclear power generation system can play a major role in achieving energy self-sufficiency in Canada. The benefits of nuclear power, factors affecting projections of electric power demand, risks and benefits relative to other conventional and non-conventional energy sources, power economics, and uranium supply are discussed from a Canadian perspective. (LL)

  12. A hybrid electrical power system for aircraft application.

    Science.gov (United States)

    Lee, C. H.; Chin, C. Y.

    1971-01-01

    Possible improvements to present aircraft electrical power systems for use in future advanced types of aircraft have been investigated. The conventional power system is examined, the characteristics of electric loads are reviewed, and various methods of power generation and distribution are appraised. It is shown that a hybrid system, with variable-frequency generation and high-voltage dc distribution, could overcome some of the limitations of the conventional system.

  13. 4onse: four times open & non-conventional technology for sensing the environment

    Science.gov (United States)

    Cannata, Massimiliano; Ratnayake, Rangageewa; Antonovic, Milan; Strigaro, Daniele; Cardoso, Mirko; Hoffmann, Marcus

    2017-04-01

    The availability of complete, quality and dense monitoring hydro-meteorological data is essential to address a number of practical issues including, but not limited to, flood-water and urban drainage management, climate change impact assessment, early warning and risk management, now-casting and weather predictions. Thanks to the recent technological advances such as Internet Of Things, Big Data and Ubiquitous Internet, non-conventional monitoring systems based on open technologies and low cost sensors may represent a great opportunity either as a complement of authoritative monitoring network or as a vital source of information wherever existing monitoring networks are in decline or completely missing. Nevertheless, scientific literature on such a kind of open and non-conventional monitoring systems is still limited and often relates to prototype engineering and testing in rather limited case studies. For this reason the 4onse project aims at integrating existing open technologies in the field of Free & Open Source Software, Open Hardware, Open Data, and Open Standards and evaluate this kind of system in a real case (about 30 stations) for a medium period of 2 years to better scientifically understand strengths, criticalities and applicabilities in terms of data quality; system durability; management costs; performances; sustainability. The ultimate objective is to contribute in non-conventional monitoring systems adoption based on four open technologies.

  14. Process data validation according VDI 2048 in conventional and nuclear power plants

    International Nuclear Information System (INIS)

    Langenstein, M.; Laipple, B.; Schmid, F.

    2004-01-01

    Process data validation according VDI 2048 in conventional and nuclear power plants is required for acceptance testing, process and component monitoring, and status-oriented maintenance. Once a validation system like VALI III has been certified according to VDI 2048, power plant owners can use the data obtained for efficiency increase. Further, all control variables can be adjusted so as to ensure maximum plant efficiency. (orig.)

  15. Conventional and advanced exergetic analyses applied to a combined cycle power plant

    International Nuclear Information System (INIS)

    Petrakopoulou, Fontina; Tsatsaronis, George; Morosuk, Tatiana; Carassai, Anna

    2012-01-01

    Conventional exergy-based methods pinpoint components and processes with high irreversibilities. However, they lack certain insight. For a given advanced technological state, there is a minimum level of exergy destruction related to technological and/or economic constraints that is unavoidable. Furthermore, in any thermodynamic system, exergy destruction stems from both component interactions (exogenous) and component inefficiencies (endogenous). To overcome the limitations of the conventional analyses and to increase our knowledge about a plant, advanced exergy-based analyses have been developed. In this paper, a combined cycle power plant is analyzed using both conventional and advanced exergetic analyses. Except for the expander of the gas turbine system and the high-pressure steam turbine, most of the exergy destruction in the plant components is unavoidable. This unavoidable part is constrained by internal technological limitations, i.e. each component’s endogenous exergy destruction. High levels of endogenous exergy destruction show that component interactions do not contribute significantly to the thermodynamic inefficiencies. In addition, these inefficiencies are unavoidable to a large extent. With the advanced analysis, new improvement strategies are revealed that could not otherwise be found. -- Highlights: ► This is the first application of a complete advanced exergetic analysis to a complex power plant. ► In the three-pressure-level combined cycle power plant studied here, the improvement potential of the majority of the components is low, since most of the exergy destruction is unavoidable. ► Component interactions are generally of lower importance for the considered plant. ► Splitting the exogenous exergy destruction reveals one-to-one component interactions and improvement strategies. ► The advanced exergetic analysis is a necessary supplement to the conventional analysis in improving a complex system.

  16. Quality assurance grading of conventional equipment at nuclear power station

    International Nuclear Information System (INIS)

    Li Ping; Li Shichang

    2006-01-01

    Equipment QA grading with the systematic and standardized approach will benefit the concerned organizations by effective allocating of limited resources to guarantee the quality of essential equipment. This paper presents a new quality assurance grading system for the convention systems/equipment of nuclear power station, which is operative and at the same time could help the owner to allot resource reasonably through the analysis of the purpose of grading and the experience and lessons of LINGAO Phase I project. (authors)

  17. Economic Operation of Power Systems with Significant Wind Power Penetration

    DEFF Research Database (Denmark)

    Farashbashi-Astaneh, Seyed-Mostafa

    This dissertation addresses economic operation of power systems with high penetration of wind power. Several studies are presented to address the economic operation of power systems with high penetration of variable wind power. The main concern in such power systems is high variability...... and unpredictability. Unlike conventional power plants, the output power of a wind farm is not controllable. This brings additional complexity to operation and planning of wind dominant power systems. The key solution in face of wind power uncertainty is to enhance power system flexibility. The enhanced flexibility......, cooperative wind-storage operation is studied. Lithium-Ion battery units are chosen as storage units. A novel formulation is proposed to investigate optimal operation of a storage unit considering power system balancing conditions and wind power imbalances. An optimization framework is presented to increase...

  18. Non-Cooled Power System for Venus Lander

    Science.gov (United States)

    Salazar, Denise; Landis, Geoffrey A.; Colozza, Anthony J.

    2014-01-01

    The Planetary Science Decadal Survey of 2013-2022 stated that the exploration of Venus is of significant interest. Studying the seismic activity of the planet is of particular importance because the findings can be compared to the seismic activity of Earth. Further, the geological and atmospheric properties of Venus will shed light into the past and future of Earth. This paper presents a radioisotope power system (RPS) design for a small low-power Venus lander. The feasibility of the new power system is then compared to that of primary batteries. A requirement for the power source system is to avoid moving parts in order to not interfere with the primary objective of the mission - to collect data about the seismic activity of Venus using a seismometer. The target mission duration of the lander is 117 days, a significant leap from Venera 13, the longest-lived lander on the surface of Venus, which survived for 2 hours. One major assumption for this mission design is that the power source system will not provide cooling to the other components of the lander. This assumption is based on high-temperature electronics technology that will enable the electronics and components of the lander to operate at Venus surface temperature. For the proposed RPS, a customized General Purpose Heat Source Radioisotope Thermoelectric Generator (GPHSRTG) is designed and analyzed. The GPHS-RTG is chosen primarily because it has no moving parts and it is capable of operating for long duration missions on the order of years. This power system is modeled as a spherical structure for a fundamental thermal analysis. The total mass and electrical output of the system are calculated to be 24 kilograms and 26 Watts, respectively. An alternative design for a battery-based power system uses Sodium Sulfur batteries. To deliver a similar electrical output for 117 days, the battery mass is calculated to be 234 kilograms. Reducing mission duration or power required will reduce the required battery mass

  19. Risk management of non-renewable energy systems

    CERN Document Server

    Verma, Ajit Kumar; Muruva, Hari Prasad

    2015-01-01

    This book describes the basic concepts of risk and reliability with detailed descriptions of the different levels of probabilistic safety assessment of nuclear power plants (both internal and external). The book also maximizes readers insights into time dependent risk analysis through several case studies, whilst risk management with respect to non renewable energy sources is also explained. With several advanced reactors utilizing the concept of passive systems, the reliability estimation of these systems are explained in detail with the book providing a reliability estimation of components through mechanistic model approach. This book is useful for advanced undergraduate and post graduate students in nuclear engineering, aerospace engineering, industrial engineering, reliability and safety engineering, systems engineering and applied probability and statistics. This book is also suitable for one-semester graduate courses on risk management of non renewable energy systems in all conventional engineering bran...

  20. Power Electronics in Wind Turbine Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Chen, Zhe; Teodorescu, Remus

    2006-01-01

    the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power systems, power production and end-user application. This paper discuss the most emerging renewable energy source, wind energy, which by means of power...... electronics is changing from being a minor energy source to be acting as an important power source in the energy system. By that wind power is also getting an added value in the power system operation....

  1. Study of antioxidant activity of non-conventional Brazilian fruits.

    Science.gov (United States)

    Luzia, D M M; Jorge, N

    2014-06-01

    This study aimed to analyze the proximate composition of seeds from some non-conventional Brazilian fruits, as well as to evaluate the antioxidant activity through DPPH(•) free radical and to quantify the total phenolic compounds. To obtain the extracts, dried and crushed seeds were extracted with ethanol for 30 min, in a ratio of 1:3 (seeds:ethyl alcohol), under continuous agitation, at room temperature. Then, the mixtures were filtered and the supernatants were subjected to rotary evaporator under pressure reduced to 40 °C. The results report that the seeds of non-conventional fruits are remarkable sources of lipids, and the extraction of oil from these seeds could be an alternative for the commercial utilization of waste. They also presented significant percentages of protein and carbohydrates. Ethanol extracts of seeds from non-conventional Brazilian fruits showed relevant antioxidant activity and high amount of phenolic compounds. Therefore Brazilian non-conventional fruits can be used as functional food products or feed.

  2. Design of Range Adaptive Wireless Power Transfer System Using Non-coaxial Coils

    Science.gov (United States)

    Yang, Dongsheng; Won, Sokhui; Hong, Huan

    2017-05-01

    Wireless Power Transfer (WPT) is a remarkable technology because of its convenience and applicability in harsh environment. Particularly, Magnetic Coupling WPT (MC-WPT) is a proper method to midrange power transfer, but the frequency splitting at over-coupling range, which is related with transfer distance, is challenge of transmission efficiency. In order to overcome this phenomenon, recently the range adaptive WPT is proposed. In this paper, we aim to the type with a set of non-coaxial driving coils, so that this may remove the connection wires from PA (Power Amplifier) to driving coil. And, when the radius of driving coil is changed, on the different gaps between driving and TX coils, coupling coefficient between these is computed in both cases of coaxial and non-coaxial configurations. In addition, the designing steps for 4-coil WPT system using non-coaxial coils are described with the example. Finally, the reliability of this topology has been proved and simulated with PSPICE.

  3. A survey of techniques applied to non-stationary waveforms in electrical power systems

    NARCIS (Netherlands)

    Rodrigues, R.P.; Silveira, P.M.; Ribeiro, P.F.

    2010-01-01

    The well-known and ever-present time-varying and non-stationary nature of waveforms in power systems requires a comprehensive and precise analytical basis that needs to be incorporated in the system studies and analyses. This time-varying behavior is due to continuous changes in system

  4. Cost comparison of dry-type and conventional cooling systems for representative nuclear generating plans

    International Nuclear Information System (INIS)

    Rossie, J.P.; Cecil, E.A.; Young, R.O.

    1974-01-01

    Results are presented of studies comparing the use of dry-type cooling towers with conventional cooling methods for representative pressurized-water-reactor nuclear power plants. The studies were based on the hypothetical use of dry-type cooling towers for three nuclear power plants now under construction which were designed and are being built to use conventional cooling methods. One of the plants is located in the northeastern United States, one in the Southeast and one in the West. The report also presents the results of comparisons based on a hypothetical plant at a typical eastern United States site. The three electric utilities which participated in these studies have furnished actual construction cost information for the conventional cooling systems being constructed, and the authors have made construction estimates for economically optimum dry cooling systems which might have been built in place of the conventional cooling systems being constructed. The report compares the physical and operating characteristics of dry-type and conventional cooling systems as well as the relative economics of the different cooling methods. The effect of dry cooling on the bus-bar cost of power has been computed for the three selected plants and for the typical eastern plant

  5. Non-contact finger vein acquisition system using NIR laser

    Science.gov (United States)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  6. Technical Feasibility Study of Thermal Energy Storage Integration into the Conventional Power Plant Cycle

    Directory of Open Access Journals (Sweden)

    Jacek D. Wojcik

    2017-02-01

    Full Text Available The current load balance in the grid is managed mainly through peaking fossil-fuelled power plants that respond passively to the load changes. Intermittency, which comes from renewable energy sources, imposes additional requirements for even more flexible and faster responses from conventional power plants. A major challenge is to keep conventional generation running closest to the design condition with higher load factors and to avoid switching off periods if possible. Thermal energy storage (TES integration into the power plant process cycle is considered as a possible solution for this issue. In this article, a technical feasibility study of TES integration into a 375-MW subcritical oil-fired conventional power plant is presented. Retrofitting is considered in order to avoid major changes in the power plant process cycle. The concept is tested based on the complete power plant model implemented in the ProTRAX software environment. Steam and water parameters are assessed for different TES integration scenarios as a function of the plant load level. The best candidate points for heat extraction in the TES charging and discharging processes are evaluated. The results demonstrate that the integration of TES with power plant cycle is feasible and provide a provisional guidance for the design of the TES system that will result in the minimal influence on the power plant cycle.

  7. Application of computational intelligence techniques for load shedding in power systems: A review

    International Nuclear Information System (INIS)

    Laghari, J.A.; Mokhlis, H.; Bakar, A.H.A.; Mohamad, Hasmaini

    2013-01-01

    Highlights: • The power system blackout history of last two decades is presented. • Conventional load shedding techniques, their types and limitations are presented. • Applications of intelligent techniques in load shedding are presented. • Intelligent techniques include ANN, fuzzy logic, ANFIS, genetic algorithm and PSO. • The discussion and comparison between these techniques are provided. - Abstract: Recent blackouts around the world question the reliability of conventional and adaptive load shedding techniques in avoiding such power outages. To address this issue, reliable techniques are required to provide fast and accurate load shedding to prevent collapse in the power system. Computational intelligence techniques, due to their robustness and flexibility in dealing with complex non-linear systems, could be an option in addressing this problem. Computational intelligence includes techniques like artificial neural networks, genetic algorithms, fuzzy logic control, adaptive neuro-fuzzy inference system, and particle swarm optimization. Research in these techniques is being undertaken in order to discover means for more efficient and reliable load shedding. This paper provides an overview of these techniques as applied to load shedding in a power system. This paper also compares the advantages of computational intelligence techniques over conventional load shedding techniques. Finally, this paper discusses the limitation of computational intelligence techniques, which restricts their usage in load shedding in real time

  8. High power communication satellites power systems study

    Science.gov (United States)

    Josloff, Allan T.; Peterson, Jerry R.

    1995-01-01

    This paper discusses a planned study to evaluate the commercial attractiveness of high power communication satellites and assesses the attributes of both conventional photovoltaic and reactor power systems. These high power satellites can play a vital role in assuring availability of universally accessible, wide bandwidth communications, for high definition TV, super computer networks and other services. Satellites are ideally suited to provide the wide bandwidths and data rates required and are unique in the ability to provide services directly to the users. As new or relocated markets arise, satellites offer a flexibility that conventional distribution services cannot match, and it is no longer necessary to be near population centers to take advantage of the telecommunication revolution. The geopolitical implications of these substantially enhanced communications capabilities can be significant.

  9. Power control and management of the grid containing largescale wind power systems

    Science.gov (United States)

    Aula, Fadhil Toufick

    The ever increasing demand for electricity has driven many countries toward the installation of new generation facilities. However, concerns such as environmental pollution and global warming issues, clean energy sources, high costs associated with installation of new conventional power plants, and fossil fuels depletion have created many interests in finding alternatives to conventional fossil fuels for generating electricity. Wind energy is one of the most rapidly growing renewable power sources and wind power generations have been increasingly demanded as an alternative to the conventional fossil fuels. However, wind power fluctuates due to variation of wind speed. Therefore, large-scale integration of wind energy conversion systems is a threat to the stability and reliability of utility grids containing these systems. They disturb the balance between power generation and consumption, affect the quality of the electricity, and complicate load sharing and load distribution managing and planning. Overall, wind power systems do not help in providing any services such as operating and regulating reserves to the power grid. In order to resolve these issues, research has been conducted in utilizing weather forecasting data to improve the performance of the wind power system, reduce the influence of the fluctuations, and plan power management of the grid containing large-scale wind power systems which consist of doubly-fed induction generator based energy conversion system. The aims of this research, my dissertation, are to provide new methods for: smoothing the output power of the wind power systems and reducing the influence of their fluctuations, power managing and planning of a grid containing these systems and other conventional power plants, and providing a new structure of implementing of latest microprocessor technology for controlling and managing the operation of the wind power system. In this research, in order to reduce and smooth the fluctuations, two

  10. Conventional power sources for colliders

    International Nuclear Information System (INIS)

    Allen, M.A.

    1987-07-01

    At SLAC we are developing high peak-power klystrons to explore the limits of use of conventional power sources in future linear colliders. In an experimental tube we have achieved 150 MW at 1 μsec pulse width at 2856 MHz. In production tubes for SLAC Linear Collider (SLC) we routinely achieve 67 MW at 3.5 μsec pulse width and 180 pps. Over 200 of the klystrons are in routine operation in SLC. An experimental klystron at 8.568 GHz is presently under construction with a design objective of 30 MW at 1 μsec. A program is starting on the relativistic klystron whose performance will be analyzed in the exploration of the limits of klystrons at very short pulse widths

  11. Advancement on safety management system of nuclear power for safety and non-anxiety of society

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu

    2004-01-01

    Advancement on safety management system is investigated to improve safety and non-anxiety of society for nuclear power, from the standpoint of human machine system research. First, the recent progress of R and D works of human machine interface technologies since 1980 s are reviewed and then the necessity of introducing a new approach to promote technical risk communication activity to foster safety culture in nuclear industries. Finally, a new concept of Offsite Operation and Maintenance Support Center (OMSC) is proposed as the core facility to assemble human resources and their expertise in all organizations of nuclear power, for enhancing safety and non-anxiety of society for nuclear power. (author)

  12. Role of non-conventional T lymphocytes in respiratory infections: the case of the pneumococcus.

    Directory of Open Access Journals (Sweden)

    Stoyan Ivanov

    2014-10-01

    Full Text Available Non-conventional T lymphocytes constitute a special arm of the immune system and act as sentinels against pathogens at mucosal surfaces. These non-conventional T cells (including mucosal-associated invariant T [MAIT] cells, gamma delta [γδ] T cells, and natural killer T [NKT] cells display several innate cell-like features and are rapidly activated by the recognition of conserved, stress-induced, self, and microbial ligands. Here, we review the role of non-conventional T cells during respiratory infections, with a particular focus on the encapsulated extracellular pathogen Streptococcus pneumoniae, the leading cause of bacterial pneumonia worldwide. We consider whether MAIT cells, γδ T cells, and NKT cells might offer opportunities for preventing and/or treating human pneumococcus infections.

  13. Performance analysis of conventional and sloped solar chimney power plants in China

    International Nuclear Information System (INIS)

    Cao Fei; Zhao Liang; Li Huashan; Guo Liejin

    2013-01-01

    The solar chimney power plant (SCPP) has been accepted as one of the most promising approaches for future large-scale solar energy applications. This paper reports on a heat transfer model that is used to compare the performance of a conventional solar chimney power plant (CSCPP) and two sloped solar chimney power plants (SSCPPs) with the collector oriented at 30° and 60°, respectively. The power generation from SCPPs at different latitudes in China is also analyzed. Results indicate that the larger solar collector angle leads to improved performance in winter but results in lower performance in summer. It is found that the optimal collector angle to achieve the maximum power in Lanzhou, China, is around 60°. Main factors that influence the performance of SCPPs also include the system height and the air thermophysical characteristics. The ground energy loss, reflected solar radiation, and kinetic loss at the chimney outlet are the main energy losses in SCPPs. The studies also show SSCPPs are more suitable for high latitude regions in Northwest China, but CSCPPs are suggested to be built in southeastern and eastern parts of China with the combination to the local agriculture. - Highlights: ► The optimum collector angle for maximum power generation is 60° in Lanzhou. ► Main parameters influencing performances are the system height and air property. ► Ground loss, reflected loss and outlet kinetic loss are the main energy losses. ► The sloped styles are suitable for Northwest China. ► The conventional styles are suitable for Southeast and East China.

  14. PowerFactory applications for power system analysis

    CERN Document Server

    Gonzalez-Longatt, Francisco

    2014-01-01

    This book presents a comprehensive set of guidelines and applications of DIgSILENT PowerFactory, an advanced power system simulation software package, for different types of power systems studies. Written by specialists in the field, it combines expertise and years of experience in the use of DIgSILENT PowerFactory with a deep understanding of power systems analysis. These complementary approaches therefore provide a fresh perspective on how to model, simulate and analyse power systems. It presents methodological approaches for modelling of system components, including both classical and non-

  15. High power communication satellites power systems study

    International Nuclear Information System (INIS)

    Josloff, A.T.; Peterson, J.R.

    1994-01-01

    This paper discusses a DOE-funded study to evaluate the commercial attractiveness of high power communication satellites and assesses the attributes of both conventional photovoltaic and reactor power systems. This study brings together a preeminent US Industry/Russian team to cooperate on the role of high power communication satellites in the rapidly expanding communications revolution. These high power satellites play a vital role in assuring availability of universally accessible, wide bandwidth communications, for high definition TV, super computer networks and other services. Satellites are ideally suited to provide the wide bandwidths and data rates required and are unique in the ability to provide services directly to the users. As new or relocated markets arise, satellites offer a flexibility that conventional distribution services cannot match, and it is no longer necessary to be near population centers to take advantage of the telecommunication revolution. The geopolitical implications of these substantially enhanced communications capabilities will be significant

  16. Allocation of synchronous condensers for restoration of system short-circuit power

    DEFF Research Database (Denmark)

    Marrazi, Emanuel; Yang, Guangya; Weinreich-Jensen, Peter

    2017-01-01

    Modern power systems, employing an increasing number of converter-based renewable energy sources (RES) and decreasing the usage of conventional power plants, are leading to lower levels of short-circuit power and rotational inertia. A solution to this is the employment of synchronous condensers...... in the grid, in order to provide sufficient short-circuit power. This results in the increase of the short-circuit ratio (SCR) at transmission system bus-bars serving as points of interconnection (POI) to renewable generation. Evaluation of the required capacity and grid-location of the synchronous condensers......, isinherently a mixed integer non-linear optimization problem, which could not be done on manual basis considering each type of machine and all bus-bars. This study therefore proposes a method of optimal allocation of synchronous condensers in a hypothetic future scenario of a transmission system fed...

  17. Development of conventional fatigue database for structure materials of nuclear power plant

    International Nuclear Information System (INIS)

    Yang Bing

    2002-01-01

    Management system of the conventional fatigue database for structure materials of nuclear power plant (NPP) is developed. The database included the parameters of design curves, i.e., the stress-life, survival probability-stress-life, strain-life, survival probability-strain-life, stress-strain and survival probability-stress-strain curves, and corresponding information of materials and testing conditions. Two ways, by materials name or by the inter-bounds of material mechanical properties, are constructed to search the database. From the searched information it can be conveniently performed of the conventional fatigue design analysis and reliability assessment of structures

  18. Multi-objective optimal reactive power dispatch to maximize power system social welfare in the presence of generalized unified power flow controller

    Directory of Open Access Journals (Sweden)

    Suresh Chintalapudi Venkata

    2015-09-01

    Full Text Available In this paper a novel non-linear optimization problem is formulated to maximize the social welfare in restructured environment with generalized unified power flow controller (GUPFC. This paper presents a methodology to optimally allocate the reactive power by minimizing voltage deviation at load buses and total transmission power losses so as to maximize the social welfare. The conventional active power generation cost function is modified by combining costs of reactive power generated by the generators, shunt capacitors and total power losses to it. The formulated objectives are optimized individually and simultaneously as multi-objective optimization problem, while satisfying equality, in-equality, practical and device operational constraints. A new optimization method, based on two stage initialization and random distribution processes is proposed to test the effectiveness of the proposed approach on IEEE-30 bus system, and the detailed analysis is carried out.

  19. Non-conventional mesons at PANDA

    International Nuclear Information System (INIS)

    Giacosa, Francesco

    2015-01-01

    Non-conventional mesons, such as glueballs and tetraquarks, will be in the focus of the PANDA experiment at the FAIR facility. In this lecture we recall the basic properties of QCD and describe some features of unconventional states. We focus on the search of the not-yet discovered glueballs and the use of the extended Linear Sigma Model for this purpose, and on the already discovered but not-yet understood X, Y, Z states. (paper)

  20. The Seductive Power of an Innovation: Enrolling Non-Conventional Actors in a Drip Irrigation Community in Morocco

    Science.gov (United States)

    Benouniche, Maya; Errahj, Mostafa; Kuper, Marcel

    2016-01-01

    Purpose: The aim of this study was to analyze the motivations of non-conventional innovation actors to engage in innovation processes, how their involvement changed the technology and their own social-professional status, and to analyze their role in the diffusion of the innovation. Design/methodology/approach: We studied the innovation process of…

  1. Optimizing efficiency on conventional transformer based low power AC/DC standby power supplies

    DEFF Research Database (Denmark)

    Nielsen, Nils

    2004-01-01

    This article describes the research results for simple and cheap methods to reduce the idle- and load-losses in very low power conventional transformer based power supplies intended for standby usage. In this case "very low power" means 50 Hz/230 V-AC to 5 V-DC@1 W. The efficiency is measured...... on two common power supply topologies designed for this power level. The two described topologies uses either a series (or linear) or a buck regulation approach. Common to the test power supplies is they either are using a standard cheap off-the-shelf transformer, or one, which are loss optimized by very...

  2. Modular load flow for restructured power systems

    CERN Document Server

    Hariharan, M V; Gupta, Pragati P

    2016-01-01

    In the subject of power systems, authors felt that a re-look is necessary at some conventional methods of analysis. In this book, the authors have subjected the time-honoured load flow to a close scrutiny. Authors have discovered and discussed a new load flow procedure – Modular Load Flow. Modular Load Flow explores use of power – a scalar – as source for electrical circuits which are conventionally analysed by means of phasors – the ac voltages or currents. The method embeds Kirchhoff’s circuit laws as topological property into its scalar equations and results in a unique wonderland where phase angles do not exist! Generators are shown to have their own worlds which can be superimposed to obtain the state of the composite power system. The treatment is useful in restructured power systems where stakeholders and the system operators may desire to know individual generator contributions in line flows and line losses for commercial reasons. Solution in Modular Load Flow consists of explicit expression...

  3. Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load

    Directory of Open Access Journals (Sweden)

    Shahrokh Shojaeean

    2013-04-01

    Full Text Available Considering the growing trend of the consumption of the electric power and the global tendency to substitute new renewable sources of energy, this paper proposes a Monte Carlo based method to determine an optimal level of this change. Considering the limitation of the wind farms in continuous supply of electric power, hydrostatic power storage facilities are used beside wind farms so that the electric power could be stored and fed in a continuous flow into power systems. Due to the gradual exclusion of conventional generators and 5 percent annual load increments, LOLE index was used in order to calculate the amount of the wind power and the capacity of the necessary power storage facility. To this end, LOLE index was calculated for the first year as the reference index for the estimation of the amount of wind power and the capacity of the storage facility in consequent years. For the upcoming years, calculations have been made to account for the gradual exclusion of conventional generators in proportion to load increments. The proposed method has been implemented and simulated on IEEE-RTS test system.

  4. Large autonomous spacecraft electrical power system (LASEPS)

    Science.gov (United States)

    Dugal-Whitehead, Norma R.; Johnson, Yvette B.

    1992-01-01

    NASA - Marshall Space Flight Center is creating a large high voltage electrical power system testbed called LASEPS. This testbed is being developed to simulate an end-to-end power system from power generation and source to loads. When the system is completed it will have several power configurations, which will include several battery configurations. These configurations are: two 120 V batteries, one or two 150 V batteries, and one 250 to 270 V battery. This breadboard encompasses varying levels of autonomy from remote power converters to conventional software control to expert system control of the power system elements. In this paper, the construction and provisions of this breadboard are discussed.

  5. Optimal pole shifting controller for interconnected power system

    International Nuclear Information System (INIS)

    Yousef, Ali M.; Kassem, Ahmed M.

    2011-01-01

    Research highlights: → Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. → Power system stabilizer was designed based on optimal pole shifting controller. → The system performances was tested through load disturbances at different operating conditions. → The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. → The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex conjugate poles, respectively. This presented method yields a solution, which is optimal with respect to a quadratic performance index. The attractive feature of this method is that it enables solutions of the complex problem to be easily found without solving any non-linear algebraic Riccati equation. The present power system stabilizer is based on Riccati equation approach. The control law depends on finding the feedback gain matrix, and then the control signal is synthesized by multiplying the state variables of the power system with determined gain matrix. The gain matrix is calculated one time only, and it works over wide range of operating conditions. To validate the power of the proposed PSS, a linearized model of a simple power system consisted of a single synchronous machine connected to infinite bus bar through transmission line is simulated. The studied power system is subjected to various operating points and power system parameters changes.

  6. Optimal pole shifting controller for interconnected power system

    Energy Technology Data Exchange (ETDEWEB)

    Yousef, Ali M., E-mail: drali_yousef@yahoo.co [Electrical Eng. Dept., Faculty of Engineering, Assiut University (Egypt); Kassem, Ahmed M., E-mail: kassem_ahmed53@hotmail.co [Control Technology Dep., Industrial Education College, Beni-Suef University (Egypt)

    2011-05-15

    Research highlights: {yields} Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. {yields} Power system stabilizer was designed based on optimal pole shifting controller. {yields} The system performances was tested through load disturbances at different operating conditions. {yields} The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. {yields} The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of this approach, it is required to solve a first-order or a second-order linear matrix Lyapunov equation for shifting one real pole or two complex conjugate poles, respectively. This presented method yields a solution, which is optimal with respect to a quadratic performance index. The attractive feature of this method is that it enables solutions of the complex problem to be easily found without solving any non-linear algebraic Riccati equation. The present power system stabilizer is based on Riccati equation approach. The control law depends on finding the feedback gain matrix, and then the control signal is synthesized by multiplying the state variables of the power system with determined gain matrix. The gain matrix is calculated one time only, and it works over wide range of operating conditions. To validate the power of the proposed PSS, a linearized model of a simple power system consisted of a single synchronous machine connected to infinite bus bar through transmission line is simulated. The studied power system is subjected to various operating points and power system parameters changes.

  7. Maintenance systems and procedures used in a nuclear power station and their relevance to other industries

    International Nuclear Information System (INIS)

    Kirk, R.R.

    1985-01-01

    The maintenance systems and procedures used at the Forsmark Nuclear Power Plant in Sweden can be viewed as a model which maintenance managers in other non-nuclear industries may adapt for their purposes. With the aid of a computerized information system covering the functions of work orders, preventative maintenance, documentation and others, plus a more conventional personnel structure, the result is an efficient, confident and well informed maintenance group. By following the basic design principles of the computerized information system used at the Forsmark Nuclear Power Station plus similar personnel structures, the performance of maintenance teams in non-nuclear manufacturing, processing and other industries could be improved to the standards of those observed

  8. The renewable energy targets of the Maghreb countries: Impact on electricity supply and conventional power markets

    International Nuclear Information System (INIS)

    Brand, Bernhard; Zingerle, Jonas

    2011-01-01

    Morocco, Algeria and Tunisia, the three countries of the North African Maghreb region, are showing increased efforts to integrate renewable electricity into their power markets. Like many other countries, they have pronounced renewable energy targets, defining future shares of 'green' electricity in their national generation mixes. The individual national targets are relatively varied, reflecting the different availability of renewable resources in each country, but also the different political ambitions for renewable electricity in the Maghreb states. Open questions remain regarding the targets' economic impact on the power markets. Our article addresses this issue by applying a linear electricity market optimization model to the North African countries. Assuming a competitive, regional electricity market in the Maghreb, the model minimizes dispatch and investment costs and simulates the impact of the renewable energy targets on the conventional generation system until 2025. Special emphasis is put on investment decisions and overall system costs. - Research Highlights: →Market simulation shows impact of RES-E penetration on the conventional power system of Morocco, Algeria and Tunisia. →Noticeable effects on dispatch and investments in fossil power plants. →Reduced utilization of base-load plants - stronger investments in flexible capacities. →Overall system costs can be decreased by optimizing the RES-E goals.

  9. Improved Power System of the Future

    OpenAIRE

    Rabinowitz, Mario

    2003-01-01

    This paper is intended to provide an insight into physics and engineering that can modernize electric power systems. Topics covered are Flexible ac transmission systems (FACTS), Custom Power, Greatly improved Capacitors, Electrical Insulation, Distribution Cables, Improved Polymeric Insulation, Underground Vault Explosions, Fault Location, Smart Cables, Neutral and Ground, Corrosion and Protection, Conventional Transformers, Compact Transformers, Ferroresonance, and Solid State Transformers.

  10. Ecological impacts and damage - comparison of selected components for nuclear and conventional power plants (example of Mochovce nuclear power plant)

    International Nuclear Information System (INIS)

    Bucek, M.

    1984-01-01

    A comparison is given of ecological damage for the nuclear power plant in Mochovce and a conventional power plant with the same power. Ecological effects and damage are divided into three groups: comparable damage, ecological damage caused only by conventional power plants and ecological damage caused only by nuclear power plants. In the first group the factors compared are land requisition, consumption of utility water and air consumption. In the second group are enumerated losses of crops (cereals, sugar beet, potatoes, oleaginous plants) and losses caused by increased disease rate owing to polluted environment by conventional power plants. In the third group health hazards are assessed linked with ionizing radiation. Also considered are vent stack escapes. (E.S.)

  11. Non-conventional technologies for data collection in Brazilian dissertations and theses.

    Science.gov (United States)

    Salvador, Pétala Tuani Candido de Oliveira; Rodrigues, Cláudia Cristiane Filgueira Martins; de Lima, Kálya Yasmine Nunes; Alves, Kisna Yasmin Andrade; Santos, Viviane Euzébia Pereira

    2015-01-01

    to characterize non-conventional technologies used for data collection of dissertations and theses available in the Catalog of Theses and Dissertations (CEPEn) of the Brazilian Nursing Association (ABEn). this is a documentary research, whose data were collected in the catalogs of theses and dissertations available at the ABEn website, from Volumes XIX to XXI. The indicators collected were: academic level; educational institution; year; qualification of the author; setting; non-conventional technology used; type of technology; association with conventional techniques; methodological design; benefits and methodological limitations. from a total of 6346 studies, only 121 (1.91%) used non-conventional technologies for data collection, representing the fi nal sample of the study. it is concluded that Brazilian Nursing researches still need methodological innovations for data collection.

  12. The electrical system of nuclear power plant

    International Nuclear Information System (INIS)

    Firman Silitonga; Gunarwan Prayitno

    2009-01-01

    In these system, electrical power system is supplied from two-offsite transmission system respective main transformer and house service transformer; and reserve transformer. The electrical load in these system consist of safety electrical system and non-safety electrical system, The safety electrical and non safety electrical systems consist of four 6,9 kV AC medium voltage bus and 480 V AC low voltage bus system. The DC power system consist of four safety 125 V DC power system and the two non-safety 125 DC power systems. The equipment in these electrical system is main turbine-generator; GTG safety; GTG alternate; uninterrupted power supply (UPS) and battery system. To protect electrical equipment and building to direct stroke and non direct stroke disturbances is installed netral grounding system and lightning protection and protection the personnel to touch-voltage is installed equipment grounding system and station grounding. The lightning arrester system is connected to station station grounding system. (author)

  13. Autonomous power expert fault diagnostic system for Space Station Freedom electrical power system testbed

    Science.gov (United States)

    Truong, Long V.; Walters, Jerry L.; Roth, Mary Ellen; Quinn, Todd M.; Krawczonek, Walter M.

    1990-01-01

    The goal of the Autonomous Power System (APS) program is to develop and apply intelligent problem solving and control to the Space Station Freedom Electrical Power System (SSF/EPS) testbed being developed and demonstrated at NASA Lewis Research Center. The objectives of the program are to establish artificial intelligence technology paths, to craft knowledge-based tools with advanced human-operator interfaces for power systems, and to interface and integrate knowledge-based systems with conventional controllers. The Autonomous Power EXpert (APEX) portion of the APS program will integrate a knowledge-based fault diagnostic system and a power resource planner-scheduler. Then APEX will interface on-line with the SSF/EPS testbed and its Power Management Controller (PMC). The key tasks include establishing knowledge bases for system diagnostics, fault detection and isolation analysis, on-line information accessing through PMC, enhanced data management, and multiple-level, object-oriented operator displays. The first prototype of the diagnostic expert system for fault detection and isolation has been developed. The knowledge bases and the rule-based model that were developed for the Power Distribution Control Unit subsystem of the SSF/EPS testbed are described. A corresponding troubleshooting technique is also described.

  14. Enhanced GSA-Based Optimization for Minimization of Power Losses in Power System

    Directory of Open Access Journals (Sweden)

    Gonggui Chen

    2015-01-01

    Full Text Available Gravitational Search Algorithm (GSA is a heuristic method based on Newton’s law of gravitational attraction and law of motion. In this paper, to further improve the optimization performance of GSA, the memory characteristic of Particle Swarm Optimization (PSO is employed in GSAPSO for searching a better solution. Besides, to testify the prominent strength of GSAPSO, GSA, PSO, and GSAPSO are applied for the solution of optimal reactive power dispatch (ORPD of power system. Conventionally, ORPD is defined as a problem of minimizing the total active power transmission losses by setting control variables while satisfying numerous constraints. Therefore ORPD is a complicated mixed integer nonlinear optimization problem including many constraints. IEEE14-bus, IEEE30-bus, and IEEE57-bus test power systems are used to implement this study, respectively. The obtained results of simulation experiments using GSAPSO method, especially the power loss reduction rates, are compared to those yielded by the other modern artificial intelligence-based techniques including the conventional GSA and PSO methods. The results presented in this paper reveal the potential and effectiveness of the proposed method for solving ORPD problem of power system.

  15. Power electronics for renewable energy systems

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede

    2009-01-01

    sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. Another is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss some of the most emerging renewable energy sources......, wind energy and photovoltaics, which by means of power electronics are changing from being minor energy sources to be acting as important power sources in the energy system....

  16. Federal tax effects on the financial attractiveness of renewable versus conventional power plants

    International Nuclear Information System (INIS)

    Hill, L.J.; Hadley, S.W.

    1995-01-01

    In this paper, we examine the effects of federal tax laws on the financial attractiveness of seven renewable and four conventional electric power generating technologies adopted by investor owned utilities (IOUs) and non-utility electricity generators (NUGs). The results show that federal income tax laws applicable to renewable generating technologies generally provide very attractive financial incentives for the adoption of these technologies by IOUs and NUGs. If an IOU and NUG is subject to the alternative minimum tax, however, it may not be able to take full advantage of these financial incentives. (author)

  17. Development of structural diagram of automated dispatch control system for power consumption at non-ferrous metallurgy enterprises

    Science.gov (United States)

    Klyuev, R. V.; Bosikov, I. I.; Madaeva, M. Z.; A-V Turluev, R.

    2018-03-01

    The structural scheme of the automated control system of power consumption at the industrial enterprise is developed in the article. At the non-ferrous metallurgy enterprise, an energy inspection and a rank analysis of the electrical energy consumption of the main processing equipment were carried out. It is established that the enterprises of non-ferrous metallurgy are a complex process system consisting of a set of thousands of jointly functioning technological facilities. For the most effective estimation of power consumption of enterprises, it is reasonable to use the automated system of dispatching control of power consumption (ASDCPC). The paper presents the results of the development of the ASDCPC structural diagram that allows one to perform on-line control and management of the energy and process parameters of the main production units and the enterprise as a whole. As a result of the introduction of ASDCPC at the non-ferrous metallurgy enterprise, the consumed active power was reduced during the peak hours of the load by 20%, the specific electricity consumption - by 14%, the cost of the energy component in the cost of production of hard alloys - by 3%.

  18. Self-Oscillating Wireless Power Transfer Systems

    OpenAIRE

    Tretyakov, Sergei A.; Simovski, Constantin R.; Valagiannopoulos, Constantinos A.; Ra'di, Younes

    2017-01-01

    Conventional wireless power transfer systems consist of a microwave power generator and transmitter located at one place and a microwave power receiver located at a distance. Here we show that wireless power transfer can be realized as a single distributed microwave generator with an over-the-air feedback, so that the microwave power is generated directly at the place where the energy needs to be delivered. We demonstrate that the use of this paradigm increases efficiency and dramatically red...

  19. Comparison between Conventional OCDMA and Subcarrier Multiplexing SAC OCDMA System Based on Single Photodiode Detection

    Directory of Open Access Journals (Sweden)

    Ahmad N. A. A

    2017-01-01

    Full Text Available This paper demonstrates the comparison between conventional OCDMA system and subcarrier multiplexing (SCM SAC-OCDMA system by applying Recursive Combinatorial (RC code based on single photodiode detection (SPD. SPD is used in the receiver part to reduce the effect of multiple access interference (MAI which contributes as a dominant noise in incoherent SAC-OCDMA systems. From this analysis, the performance of SCM OCDMA network could be improved by using lower data rates and higher received power. The hybrid SCM OCDMA system shows better performance compare to conventional OCDMA system although the number of users involved is very high. This is because, for hybrid SCM OCDMA system, the number of users can be increased by increasing the number of subcarriers without affect the number of code length and optical codes. Increasing the number of subcarriers will enhance the power consumption by applying hybrid SCM system in OCDMA compared to the conventional OCDMA system. This is because increasing the number of users for hybrid SCM system does not affects the number of code length and the number of optical codes but only increase the number of subcarriers. Thus, hybrid SCM OCDMA system has to increase spectral efficiency and produce better performance compared to conventional of OCDMA system.

  20. Power Electronics Control of Wind Energy in Distributed Power System

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...... technology from kW to MW, discuss which power electronic solutions are most feasible and used today....

  1. Impact of Wind Power on the Angular Stability of a Power System

    Directory of Open Access Journals (Sweden)

    Djemai NAIMI

    2008-06-01

    Full Text Available Wind energy conversion systems are very different in nature from conventional generators. Therefore dynamic studies must be addressed in order to integrate wind power into the power system. Angular stability assessment of wind power generator is one of main issues in power system security and operation. The angular stability for the wind power generator is determined by its corresponding Critical Clearing Time (CCT. In this paper, the effect of wind power on the transient fault behavior is investigated by replacing the power generated by two main types of wind turbine, increasing gradually a rate of wind power penetration and changing the location of wind resources. The simulation analysis was established on a 14 bus IEEE test system by PSAT/Matlab, which gives access to an extensive library of grid components, and relevant wind turbine model.

  2. Stakes and impact of non conventional gases on the market energy

    International Nuclear Information System (INIS)

    2010-04-01

    This article presents the content of a market study which aimed at describing the boom of the market of non conventional gases in the USA (definition, reasons for quick development, competitiveness, growth perspectives), at understanding how and why theses gases are the new playground of oil and gas companies (actors in presence, positions held by independent operators, ambitions of major companies, question of the development of a European sector of non conventional gases), and at anticipating the changes of the energy production market (the emergence of this market in the USA is an acceleration and imbalance factor of the world market of natural gas, and non conventional gases may change the deal on energy markets)

  3. Positron range in PET imaging: non-conventional isotopes

    International Nuclear Information System (INIS)

    Jødal, L; Le Loirec, C; Champion, C

    2014-01-01

    In addition to conventional short-lived radionuclides, longer-lived isotopes are becoming increasingly important to positron emission tomography (PET). The longer half-life both allows for circumvention of the in-house production of radionuclides, and expands the spectrum of physiological processes amenable to PET imaging, including processes with prohibitively slow kinetics for investigation with short-lived radiotracers. However, many of these radionuclides emit ‘high-energy’ positrons and gamma rays which affect the spatial resolution and quantitative accuracy of PET images. The objective of the present work is to investigate the positron range distribution for some of these long-lived isotopes. Based on existing Monte Carlo simulations of positron interactions in water, the probability distribution of the line of response displacement have been empirically described by means of analytic displacement functions. Relevant distributions have been derived for the isotopes 22 Na, 52 Mn, 89 Zr, 45 Ti, 51 Mn, 94m Tc, 52m Mn, 38 K, 64 Cu, 86 Y, 124 I, and 120 I. It was found that the distribution functions previously found for a series of conventional isotopes (Jødal et al 2012 Phys. Med. Bio. 57 3931–43), were also applicable to these non-conventional isotopes, except that for 120 I, 124 I, 89 Zr, 52 Mn, and 64 Cu, parameters in the formulae were less well predicted by mean positron energy alone. Both conventional and non-conventional range distributions can be described by relatively simple analytic expressions. The results will be applicable to image-reconstruction software to improve the resolution. (paper)

  4. Guidelines for the verification and validation of expert system software and conventional software: Survey and documentation of expert system verification and validation methodologies. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Groundwater, E.H.; Miller, L.A.; Mirsky, S.M. [Science Applications International Corp., McLean, VA (United States)

    1995-03-01

    This report is the third volume in the final report for the Expert System Verification and Validation (V&V) project which was jointly sponsored by the Nuclear Regulatory Commission and the Electric Power Research Institute. The ultimate objective is the formulation of guidelines for the V&V of expert systems for use in nuclear power applications. The purpose of this activity was to survey and document techniques presently in use for expert system V&V. The survey effort included an extensive telephone interviewing program, site visits, and a thorough bibliographic search and compilation. The major finding was that V&V of expert systems is not nearly as established or prevalent as V&V of conventional software systems. When V&V was used for expert systems, it was almost always at the system validation stage after full implementation and integration usually employing the non-systematic dynamic method of {open_quotes}ad hoc testing.{close_quotes} There were few examples of employing V&V in the early phases of development and only weak sporadic mention of the possibilities in the literature. There is, however, a very active research area concerning the development of methods and tools to detect problems with, particularly, rule-based expert systems. Four such static-testing methods were identified which were not discovered in a comprehensive review of conventional V&V methods in an earlier task.

  5. Power System Operation with Large-Scale Wind Power in Liberalised Environments

    International Nuclear Information System (INIS)

    Ummels, B.C.

    2009-01-01

    The disadvantages of producing electricity from fossil fuels are that their supply is finite and unevenly distributed across the earth. Conventional power stations also emit greenhouse gases. Therefore, sustainable alternatives must be developed, such as wind power. The disadvantages of wind are that it may or may not blow and that it is unpredictable. Th generation of electricity must however always equal the consumption. This makes the integration of wind power in the electricity system more difficult. This thesis investigates the integration of wind power into the existing power system. Simulation models are developed and used to explore the operation of power systems with a lot of wind power. The simulations provide a picture of the reliability, cost and emission of CO2 of the generation of electricity, with and without wind power. The research also takes into account electricity exchange on international markets. Possible solutions for integrating wind power, such as flexible power plants and energy storage, are investigated as well

  6. Review of Aircraft Electric Power Systems and Architectures

    DEFF Research Database (Denmark)

    Zhao, Xin; Guerrero, Josep M.; Wu, Xiaohao

    2014-01-01

    In recent years, the electrical power capacity is increasing rapidly in more electric aircraft (MEA), since the conventional mechanical, hydraulic and pneumatic energy systems are partly replaced by electrical power system. As a consequence, capacity and complexity of aircraft electric power...... systems (EPS) will increase dramatically and more advanced aircraft EPSs need to be developed. This paper gives a brief description of the constant frequency (CF) EPS, variable frequency (VF) EPS and advanced high voltage (HV) EPS. Power electronics in the three EPS is overviewed. Keywords: Aircraft Power...... System, More Electric Aircraft, Constant Frequency, Variable Frequency, High Voltage....

  7. Conventional and unconventional political participation

    International Nuclear Information System (INIS)

    Opp, K.D.

    1985-01-01

    A non-recursive model is proposed and empirically tested with data of opponents of nuclear power. In explaining conventional and unconventional participation the theory of collective action is applied and modified in two respects: the perceived influence on the elimination of collective evils are taken into account; the selective incentives considered are non-material ones. These modifications proved to be valid: the collective good variables and non-material incentives were important determinants for the two forms of participation. Another result was that there is a reciprocal causal relationship between conventional and unconventional participation. (orig./PW) [de

  8. Wind power integration into the automatic generation control of power systems with large-scale wind power

    Directory of Open Access Journals (Sweden)

    Abdul Basit

    2014-10-01

    Full Text Available Transmission system operators have an increased interest in the active participation of wind power plants (WPP in the power balance control of power systems with large wind power penetration. The emphasis in this study is on the integration of WPPs into the automatic generation control (AGC of the power system. The present paper proposes a coordinated control strategy for the AGC between combined heat and power plants (CHPs and WPPs to enhance the security and the reliability of a power system operation in the case of a large wind power penetration. The proposed strategy, described and exemplified for the future Danish power system, takes the hour-ahead regulating power plan for generation and power exchange with neighbouring power systems into account. The performance of the proposed strategy for coordinated secondary control is assessed and discussed by means of simulations for different possible future scenarios, when wind power production in the power system is high and conventional production from CHPs is at a minimum level. The investigation results of the proposed control strategy have shown that the WPPs can actively help the AGC, and reduce the real-time power imbalance in the power system, by down regulating their production when CHPs are unable to provide the required response.

  9. Ultracapacitor-Based Uninterrupted Power Supply System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2011-01-01

    The ultracapacitor-based uninterrupted power supply (UPS) system enhances system reliability; reduces life-of-system, maintenance, and downtime costs; and greatly reduces environmental impact when compared to conventional UPS energy storage systems. This design provides power when required and absorbs power when required to smooth the system load and also has excellent low-temperature performance. The UPS used during hardware tests at Glenn is an efficient, compact, maintenance-free, rack-mount, pure sine-wave inverter unit. The UPS provides a continuous output power up to 1,700 W with a surge rating of 1,870 W for up to one minute at a nominal output voltage of 115 VAC. The ultracapacitor energy storage system tested in conjunction with the UPS is rated at 5.8 F. This is a bank of ten symmetric ultracapacitor modules. Each module is actively balanced using a linear voltage balancing technique in which the cell-to-cell leakage is dependent upon the imbalance of the individual cells. The ultracapacitors are charged by a DC power supply, which can provide up to 300 VDC at 4 A. A constant-voltage, constant-current power supply was selected for this application. The long life of ultracapacitors greatly enhances system reliability, which is significant in critical applications such as medical power systems and space power systems. The energy storage system can usually last longer than the application, given its 20-year life span. This means that the ultracapacitors will probably never need to be replaced and disposed of, whereas batteries require frequent replacement and disposal. The charge-discharge efficiency of rechargeable batteries is approximately 50 percent, and after some hundreds of charges and discharges, they must be replaced. The charge-discharge efficiency of ultracapacitors exceeds 90 percent, and can accept more than a million charges and discharges. Thus, there is a significant energy savings through the efficiency improvement, and there is far less

  10. Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2011-01-01

    A grid-tied photovoltaic (PV) power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. Operating costs of a PV power system are low compared to conventional power technologies. This method can displace the highest-cost electricity during times of peak demand in most climatic regions, and thus reduce grid loading. Net metering is often used, in which independent power producers such as PV power systems are connected to the utility grid via the customers main service panels and meters. When the PV power system is generating more power than required at that location, the excess power is provided to the utility grid. The customer pays the net of the power purchased when the on-site power demand is greater than the onsite power production, and the excess power is returned to the utility grid. Power generated by the PV system reduces utility demand, and the surplus power aids the community. Modern PV panels are readily available, reliable, efficient, and economical, with a life expectancy of at least 25 years. Modern electronics have been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy equal to the modern PV panels. The grid-tied PV power system was successfully designed and developed, and this served to validate the basic principles developed, and the theoretical work that was performed. Grid-tied PV power systems are reliable, maintenance- free, long-life power systems, and are of significant value to NASA and the community. Of particular value are the analytical tools and capabilities that have been successfully developed. Performance predictions can be made confidently for grid-tied PV systems of various scales. The work was done under the NASA Hybrid Power Management (HPM

  11. A pilot project on non-conventional learning

    OpenAIRE

    Fernandes, Sara; Cerone, Antonio; Barbosa, L. S.

    2013-01-01

    This poster presents a pilot project on non-conventional learning strategies based on students’ active participation in real-life FLOSS projects. The aim of the project is to validate the hypothesis that the peer-production model, which underlies most FLOSS projects, can enhance the learning-teaching process based on extensive and systematic collaborative practices.

  12. A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yap Hoon

    2017-02-01

    Full Text Available In this paper, a refined reference current generation algorithm based on instantaneous power (pq theory is proposed, for operation of an indirect current controlled (ICC three-level neutral-point diode clamped (NPC inverter-based shunt active power filter (SAPF under non-sinusoidal source voltage conditions. SAPF is recognized as one of the most effective solutions to current harmonics due to its flexibility in dealing with various power system conditions. As for its controller, pq theory has widely been applied to generate the desired reference current due to its simple implementation features. However, the conventional dependency on self-tuning filter (STF in generating reference current has significantly limited mitigation performance of SAPF. Besides, the conventional STF-based pq theory algorithm is still considered to possess needless features which increase computational complexity. Furthermore, the conventional algorithm is mostly designed to suit operation of direct current controlled (DCC SAPF which is incapable of handling switching ripples problems, thereby leading to inefficient mitigation performance. Therefore, three main improvements are performed which include replacement of STF with mathematical-based fundamental real power identifier, removal of redundant features, and generation of sinusoidal reference current. To validate effectiveness and feasibility of the proposed algorithm, simulation work in MATLAB-Simulink and laboratory test utilizing a TMS320F28335 digital signal processor (DSP are performed. Both simulation and experimental findings demonstrate superiority of the proposed algorithm over the conventional algorithm.

  13. Microbial terroir in Chilean valleys: Diversity of non-conventional yeast

    Directory of Open Access Journals (Sweden)

    Carla eJara

    2016-05-01

    Full Text Available In this study, the presence of non-conventional yeast associated with vineyards located between latitudes 30ºS and 36ºS was examined, including the valleys of Limarí, Casablanca, Maipo, Colchagua, Maule and Itata. The microbial fingerprinting in each valley was examined based on the specific quantification of yeast of enological interest. Grape berries were sampled to evaluate the presence and load of non-conventional yeast with enological potential, such as Metschnikowia, Hanseniaspora, Torulaspora, Debaryomyces, Meyerozyma and Rhodotorula. These yeasts were present in all vineyards studied but with varying loads depending on the valley sampled. No identical fingerprints were observed; however, similarities and differences could be observed among the microbial profiles of each valley. A co-variation in the loads of Metschnikowia and Hanseniaspora with latitude was observed, showing high loads in the Casablanca and Itata valleys, which was coincident with the higher relative humidity or rainfall of those areas. Non-conventional yeasts were also isolated and identified after sequencing molecular markers. Potentially good aromatic properties were also screened among the isolates, resulting in the selection of mostly Metschnikowia and Hanseniaspora isolates. Finally, our results suggest that microbial terroir might be affected by climatic conditions such as relative humidity and rainfall, especially impacting the load of non-conventional yeast. In this study, the microbial fingerprint for yeast in Chilean vineyards is reported for the first time revealing an opportunity to study the contribution of this assembly of microorganisms to the final product.

  14. Coordinated Frequency Control of Wind Turbines in Power Systems with High Wind Power Penetration

    DEFF Research Database (Denmark)

    Tarnowski, Germán Claudio

    The integration of large amounts of wind power in power systems presents huge challenges. In particular, with the increase of wind power generation, more regulation reserves would be necessary, the capability of the power system to offer conventional regulating power would be reduced...... particular views. These models were developed and verified during this work, basedaround a particular manufacturer’s wind turbine and on said isolated power system withwind power. The capability of variable speed wind turbines for providing Inertial Response is analysed. To perform this assessment, a control...... generation were studied considering a large share of wind power in the system. Results show the abilities of the architectures to manage the variability of the generated wind power, reducing the impact on the grid frequency and providing suitable frequency regulation service when required. The coordination...

  15. Wear Resistance Performance of Conventional and Non-Conventional Wind Turbine Blades with TiN Nano-Coating

    Directory of Open Access Journals (Sweden)

    Muhammad Hasibul Hasan

    2017-09-01

    Full Text Available Efficiency and durability are critical issues that affect widely-adopted aerofoil-power generator as a sustainable source of electrical power. Even though high wind power density can be achieved; installing wind turbines in desert condition has difficulties including thermal variation, high turbulence and sand storms. Sand blasting on turbine blade surface at high velocities causes erosion resulting turbine efficiency drop. Damage-induced erosion phenomena and aeroelastic performance of the blades needed to be investigated. Suitable coating may prevent erosion to a great extent. A numerical investigation of erosion on NACA 4412 wind turbine blade has been performed using commercial computational fluid dynamics software ANSYS FLUENT 14.5 release. Discrete phase model (DPM has been used for modelling multi-phase flow of air and sand particles over the turbine blade. Governing equations have been solved by finite volume method (FVM. Conventional 30-70% glass fibre resin and non-conventional jute fibre composite have been used as turbine blade material. Sand particles of  diameter have been injected from 20, 30, 45, 60 and 90 degree angles at 500C temperature. Erosion rate, wall shear stress and strain rate have been calculated for different wind velocities and impingement angles. Simulation results for higher velocities deviate from the results observed at lower wind velocities. In simulation, erosion rate is highest for impingement angle at low wind velocities, which has been validated by experiment with a mean absolute error (MAE of 5.56%. Erosion rate and wall shear stress are higher on jute composite fibre than glass fibre resin. Developed shear stress on wind turbine blade surface is highest for  impingement angle at all velocities. On the other hand, exerted pressure on turbine blade surface is found highest for 9  angle of attack. Experimental results, with or without Titanium nitride(TiN nano-coating, also revealed that surface roughness

  16. Power system stabilizers based on modern control techniques

    Energy Technology Data Exchange (ETDEWEB)

    Malik, O P; Chen, G P; Zhang, Y; El-Metwally, K [Calgary Univ., AB (Canada). Dept. of Electrical and Computer Engineering

    1994-12-31

    Developments in digital technology have made it feasible to develop and implement improved controllers based on sophisticated control techniques. Power system stabilizers based on adaptive control, fuzzy logic and artificial networks are being developed. Each of these control techniques possesses unique features and strengths. In this paper, the relative performance of power systems stabilizers based on adaptive control, fuzzy logic and neural network, both in simulation studies and real time tests on a physical model of a power system, is presented and compared to that of a fixed parameter conventional power system stabilizer. (author) 16 refs., 45 figs., 3 tabs.

  17. Added values of photovoltaic power systems

    International Nuclear Information System (INIS)

    2001-03-01

    The structure, ownership and operation of electricity systems around the world are changing in response to industry restructuring, the availability of new technologies and increasing environmental awareness. At the same time, many countries have yet to provide basic energy services for their populations, particularly in areas not served by the electricity grid. Large-scale, central power generation and distribution which characterized the electricity industry for much of the 20 th century is being challenged by new technologies, which are cleaner, faster to deploy and better matched to local requirements. Higher values are being placed on ancillary services, such as power system reliability and voltage stability, so that a simple comparison of energy cost is no longer appropriate as a measure of competitiveness. Solar photovoltaic electricity is unique amongst the new energy sources for the wide range of energy and non-energy benefits which can be provided, while the use of photovoltaic power systems as an integral part of a building provides the greatest opportunity for exploiting non-energy benefits and for adding value to the photovoltaic power system. This report documents the potential added values or non-energy benefits photovoltaic power systems can provide, the current state of market development and the key barriers faced by renewable energy technologies generally and photovoltaic power systems in particular. Means by which non-energy benefits may be used to overcome barriers to the use of photovoltaic power systems are then discussed, with specific attention to the use of building integrated photovoltaics. (author)

  18. Added values of photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-15

    The structure, ownership and operation of electricity systems around the world are changing in response to industry restructuring, the availability of new technologies and increasing environmental awareness. At the same time, many countries have yet to provide basic energy services for their populations, particularly in areas not served by the electricity grid. Large-scale, central power generation and distribution which characterized the electricity industry for much of the 20{sup th} century is being challenged by new technologies, which are cleaner, faster to deploy and better matched to local requirements. Higher values are being placed on ancillary services, such as power system reliability and voltage stability, so that a simple comparison of energy cost is no longer appropriate as a measure of competitiveness. Solar photovoltaic electricity is unique amongst the new energy sources for the wide range of energy and non-energy benefits which can be provided, while the use of photovoltaic power systems as an integral part of a building provides the greatest opportunity for exploiting non-energy benefits and for adding value to the photovoltaic power system. This report documents the potential added values or non-energy benefits photovoltaic power systems can provide, the current state of market development and the key barriers faced by renewable energy technologies generally and photovoltaic power systems in particular. Means by which non-energy benefits may be used to overcome barriers to the use of photovoltaic power systems are then discussed, with specific attention to the use of building integrated photovoltaics. (author)

  19. Optimization of photovoltaic power systems

    CERN Document Server

    Rekioua, Djamila

    2012-01-01

    Photovoltaic generation is one of the cleanest forms of energy conversion available. One of the advantages offered by solar energy is its potential to provide sustainable electricity in areas not served by the conventional power grid. Optimisation of Photovoltaic Power Systems details explicit modelling, control and optimisation of the most popular stand-alone applications such as pumping, power supply, and desalination. Each section is concluded by an example using the MATLAB(R) and Simulink(R) packages to help the reader understand and evaluate the performance of different photovoltaic syste

  20. Bus Participation Factor Analysis for Harmonic Instability in Power Electronics Based Power Systems

    DEFF Research Database (Denmark)

    Ebrahimzadeh, Esmaeil; Blaabjerg, Frede; Wang, Xiongfei

    2018-01-01

    Compared with the conventional power systems, large-scale power electronics based power systems present a more complex situation, where harmonic instability may be induced by the mutual interactions between the inner control loops of the converters. This paper presents an approach to locate which...... power converters and buses are more sensitive and have significant contribution to the harmonic instability. In the approach, a power electronics based system is introduced as a Multi-Input Multi-Output (MIMO) dynamic system by means of a dynamic admittance matrix. Bus Participation Factors (PFs......) are calculated by the oscillatory mode sensitivity analysis versus the elements of the MIMO transfer function matrix. The PF analysis detects which power electronic converters or buses have a higher participation in harmonic instability excitation than others or at which buses such instability problems have...

  1. WAMS Based Intelligent Operation and Control of Modern Power System with large Scale Renewable Energy Penetration

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain

    security limits. Under such scenario, progressive displacement of conventional generation by wind generation is expected to eventually lead a complex power system with least presence of central power plants. Consequently the support from conventional power plants is expected to reach its all-time low...... system voltage control responsibility from conventional power plants to wind turbines. With increased wind penetration and displaced conventional central power plants, dynamic voltage security has been identified as one of the challenging issue for large scale wind integration. To address the dynamic...... security issue, a WAMS based systematic voltage control scheme for large scale wind integrated power system has been proposed. Along with the optimal reactive power compensation, the proposed scheme considers voltage support from wind farms (equipped with voltage support functionality) and refurbished...

  2. Fault ride-through requirements for onshore wind power plants in Europe: the needs of the power system

    NARCIS (Netherlands)

    Boemer, J.C.; Meer, van der A.A.; Rawn, B.G.; Hendriks, R.L.; Ciupuliga, A.R.; Gibescu, M.; Kling, W.L.; Ferreira, J.A.

    2011-01-01

    Wind power plants show different behavior than conventional (synchronous) generators. As the traditional power systems mainly consisted of centralized generation by synchronous machines feeding passive loads, it was well-understood how the system reacted in normal operation as well as during

  3. Harmonics in Offshore Wind Power Plants Employing Power Electronic Devices in the Transmission System

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm

    Introduction The trend in power generation is to partly replace conventional power plants with renewable energy sources. Offshore wind power has been selected to take up a significant proportion of the renewable energy production. The grid codes have been updated to accommodate the rising share...... of wind power. The onshore as well as offshore wind power plants (OWPPs) therefore have to meet the same stringent requirement as the conventional power plants. This can be accommodated by employment of flexible alternating current transmission system (FACTS) devices, such as the static compensator...... gives rise to a number of challenges to the wind power industry with regard to construction, installation as well as transmission of the generated energy. The STATCOM and the voltage-sourced converter high-voltage direct current (VSC-HVDC) are attractive solutions for grid connection of remotely located...

  4. State-of-art report on digital I and C system reliability issues for nuclear power plants

    International Nuclear Information System (INIS)

    Hwang, In Koo; Lee, Dong Gyoung; Cha, Kyung Ho; Kwon, Kee Choon; Wood, Richard T.

    2000-01-01

    As the instrumentation and control (Iand C) equipment suppliers tend to provide digital components rather than conventional analog type components for instrument and control systems of nuclear power plants(NPPs), it is unavoidable to adopt digital equipment for safety I and C systems as well as non-safety systems. However, the full introduction of digital equipment to I and C systems of nuclear power plants raises several concerns which have not been considered for conventional analog I and C systems. The two major examples of the issues of digital systems are electromagnetic compatibility (EMC) and software reliability. KAERI invited a technical expert, Dr. Richard T. Wood, from Oak Ridge National Laboratory (ORNL) in Unites States and held seminars to recognize the state-of-art of the above issues and to share the information on techniques dealing with the problems. Dr. Wood has been working on the development of EMC guidelines and technical basis in using digital equipment for safety systems in nuclear power plants on the sponsorship of US Nuclear Regulatory Commission (NRC). Being based on his statements and discussions during his visit, this report describes technical considerations and issues on digital safety I and C system application in NPPs, EMC methods, environmental effects vulnerable to digital components, reliability assurance methods, etc. (author)

  5. Fundamental properties of and transition to a fully renewable pan-European power system

    DEFF Research Database (Denmark)

    Bruun Andresen, Gorm; Rasmussen, Morten Grud; Rodriguez, Rolando A.

    2012-01-01

    We introduce a top-down stylized model to analyse the impact of a transition to a European power system based only on wind and solar power. Wind and solar power generation is calculated from high-resolution weather data and based on the country specific electricity demand alone, we introduce...... a model of the conventional power system that facilitates simple spatio-temporal modelling of its macroscopic behaviour without direct reference to the underlying technological, economical, and political development in the system. Using this model, we find that wind and solar power generation can replace...... conventional power generation and power capacity to a large degree if power transmission across the continent is made possible....

  6. Guidelines for the verification and validation of expert system software and conventional software: Survey and documentation of expert system verification and validation methodologies. Volume 3

    International Nuclear Information System (INIS)

    Groundwater, E.H.; Miller, L.A.; Mirsky, S.M.

    1995-03-01

    This report is the third volume in the final report for the Expert System Verification and Validation (V ampersand V) project which was jointly sponsored by the Nuclear Regulatory Commission and the Electric Power Research Institute. The ultimate objective is the formulation of guidelines for the V ampersand V of expert systems for use in nuclear power applications. The purpose of this activity was to survey and document techniques presently in use for expert system V ampersand V. The survey effort included an extensive telephone interviewing program, site visits, and a thorough bibliographic search and compilation. The major finding was that V ampersand V of expert systems is not nearly as established or prevalent as V ampersand V of conventional software systems. When V ampersand V was used for expert systems, it was almost always at the system validation stage after full implementation and integration usually employing the non-systematic dynamic method of open-quotes ad hoc testing.close quotes There were few examples of employing V ampersand V in the early phases of development and only weak sporadic mention of the possibilities in the literature. There is, however, a very active research area concerning the development of methods and tools to detect problems with, particularly, rule-based expert systems. Four such static-testing methods were identified which were not discovered in a comprehensive review of conventional V ampersand V methods in an earlier task

  7. A Modified Load Flow Algorithm in Power Systems with Alternative Energy Sources

    International Nuclear Information System (INIS)

    Contreras, D.L.; Cañedo, J.M.

    2017-01-01

    In this paper an algorithm for calculating the steady state of electrical networks including wind and photovoltaic generation is presented. The wind generators considered are; asynchronous (squirrel cage and doubly fed) and synchronous generators using permanent magnets. The proposed algorithm is based on the formulation of nodal power injections that is solved with the modified Newton Raphson technique in its polar formulation using complex matrices notation. Each power injection of wind and photovoltaic generators is calculated independently in each iteration according to its particular mathematical model, which is generally non-linear. Results are presented with a 30-node test system. The computation time of the proposed algorithm is compared with the conventional methodology to include alternative energy sources in power flows studies. (author)

  8. Energy Optimization for a Weak Hybrid Power System of an Automobile Exhaust Thermoelectric Generator

    Science.gov (United States)

    Fang, Wei; Quan, Shuhai; Xie, Changjun; Tang, Xinfeng; Ran, Bin; Jiao, Yatian

    2017-11-01

    An integrated starter generator (ISG)-type hybrid electric vehicle (HEV) scheme is proposed based on the automobile exhaust thermoelectric generator (AETEG). An eddy current dynamometer is used to simulate the vehicle's dynamic cycle. A weak ISG hybrid bench test system is constructed to test the 48 V output from the power supply system, which is based on engine exhaust-based heat power generation. The thermoelectric power generation-based system must ultimately be tested when integrated into the ISG weak hybrid mixed power system. The test process is divided into two steps: comprehensive simulation and vehicle-based testing. The system's dynamic process is simulated for both conventional and thermoelectric powers, and the dynamic running process comprises four stages: starting, acceleration, cruising and braking. The quantity of fuel available and battery pack energy, which are used as target vehicle energy functions for comparison with conventional systems, are simplified into a single energy target function, and the battery pack's output current is used as the control variable in the thermoelectric hybrid energy optimization model. The system's optimal battery pack output current function is resolved when its dynamic operating process is considered as part of the hybrid thermoelectric power generation system. In the experiments, the system bench is tested using conventional power and hybrid thermoelectric power for the four dynamic operation stages. The optimal battery pack curve is calculated by functional analysis. In the vehicle, a power control unit is used to control the battery pack's output current and minimize energy consumption. Data analysis shows that the fuel economy of the hybrid power system under European Driving Cycle conditions is improved by 14.7% when compared with conventional systems.

  9. Non-Conventional Yeast Strains Increase the Aroma Complexity of Bread

    Science.gov (United States)

    Rezaei, Mohammad Naser; Steensels, Jan; Courtin, Christophe M.; Verstrepen, Kevin J.

    2016-01-01

    Saccharomyces cerevisiae is routinely used yeast in food fermentations because it combines several key traits, including fermentation efficiency and production of desirable flavors. However, the dominance of S. cerevisiae in industrial fermentations limits the diversity in the aroma profiles of the end products. Hence, there is a growing interest in non-conventional yeast strains that can help generate the diversity and complexity desired in today’s diversified and consumer-driven markets. Here, we selected a set of non-conventional yeast strains to examine their potential for bread fermentation. Here, we tested ten non-conventional yeasts for bread fermentation, including two Saccharomyces species that are not currently used in bread making and 8 non-Saccharomyces strains. The results show that Torulaspora delbrueckii and Saccharomyces bayanus combine satisfactory dough fermentation with an interesting flavor profile. Sensory analysis and HS-SPME-GC-MS analysis confirmed that these strains produce aroma profiles that are very different from that produced by a commercial bakery strain. Moreover, bread produced with these yeasts was preferred by a majority of a trained sensory panel. These results demonstrate the potential of T. delbrueckii and S. bayanus as alternative yeasts for bread dough leavening, and provide a general experimental framework for the evaluation of more yeasts and bacteria. PMID:27776154

  10. Non-Conventional Yeast Strains Increase the Aroma Complexity of Bread.

    Science.gov (United States)

    Aslankoohi, Elham; Herrera-Malaver, Beatriz; Rezaei, Mohammad Naser; Steensels, Jan; Courtin, Christophe M; Verstrepen, Kevin J

    2016-01-01

    Saccharomyces cerevisiae is routinely used yeast in food fermentations because it combines several key traits, including fermentation efficiency and production of desirable flavors. However, the dominance of S. cerevisiae in industrial fermentations limits the diversity in the aroma profiles of the end products. Hence, there is a growing interest in non-conventional yeast strains that can help generate the diversity and complexity desired in today's diversified and consumer-driven markets. Here, we selected a set of non-conventional yeast strains to examine their potential for bread fermentation. Here, we tested ten non-conventional yeasts for bread fermentation, including two Saccharomyces species that are not currently used in bread making and 8 non-Saccharomyces strains. The results show that Torulaspora delbrueckii and Saccharomyces bayanus combine satisfactory dough fermentation with an interesting flavor profile. Sensory analysis and HS-SPME-GC-MS analysis confirmed that these strains produce aroma profiles that are very different from that produced by a commercial bakery strain. Moreover, bread produced with these yeasts was preferred by a majority of a trained sensory panel. These results demonstrate the potential of T. delbrueckii and S. bayanus as alternative yeasts for bread dough leavening, and provide a general experimental framework for the evaluation of more yeasts and bacteria.

  11. Non-Conventional Yeast Strains Increase the Aroma Complexity of Bread.

    Directory of Open Access Journals (Sweden)

    Elham Aslankoohi

    Full Text Available Saccharomyces cerevisiae is routinely used yeast in food fermentations because it combines several key traits, including fermentation efficiency and production of desirable flavors. However, the dominance of S. cerevisiae in industrial fermentations limits the diversity in the aroma profiles of the end products. Hence, there is a growing interest in non-conventional yeast strains that can help generate the diversity and complexity desired in today's diversified and consumer-driven markets. Here, we selected a set of non-conventional yeast strains to examine their potential for bread fermentation. Here, we tested ten non-conventional yeasts for bread fermentation, including two Saccharomyces species that are not currently used in bread making and 8 non-Saccharomyces strains. The results show that Torulaspora delbrueckii and Saccharomyces bayanus combine satisfactory dough fermentation with an interesting flavor profile. Sensory analysis and HS-SPME-GC-MS analysis confirmed that these strains produce aroma profiles that are very different from that produced by a commercial bakery strain. Moreover, bread produced with these yeasts was preferred by a majority of a trained sensory panel. These results demonstrate the potential of T. delbrueckii and S. bayanus as alternative yeasts for bread dough leavening, and provide a general experimental framework for the evaluation of more yeasts and bacteria.

  12. Robust Controller to Extract the Maximum Power of a Photovoltaic System

    Directory of Open Access Journals (Sweden)

    OULD CHERCHALI Noureddine

    2014-05-01

    Full Text Available This paper proposes a technique of intelligent control to track the maximum power point (MPPT of a photovoltaic system . The PV system is non-linear and it is exposed to external perturbations like temperature and solar irradiation. Fuzzy logic control is known for its stability and robustness. FLC is adopted in this work for the improvement and optimization of control performance of a photovoltaic system. Another technique called perturb and observe (P & O is studied and compared with the FLC technique. The PV system is constituted of a photovoltaic panel (PV, a DC-DC converter (Boost and a battery like a load. The simulation results are developed in MATLAB / Simulink software. The results show that the controller based on fuzzy logic is better and faster than the conventional controller perturb and observe (P & O and gives a good maximum power of a photovoltaic generator under different changes of weather conditions.

  13. Nuclear power control system design using genetic algorithm

    International Nuclear Information System (INIS)

    Lee, Yoon Joon; Cho, Kyung Ho

    1996-01-01

    The genetic algorithm(GA) is applied to the design of the nuclear power control system. The reactor control system model is described in the LQR configuration. The LQR system order is increased to make the tracking system. The key parameters of the design are weighting matrices, and these are usually determined through numerous simulations in the conventional design. To determine the more objective and optimal weightings, the improved GA is applied. The results show that the weightings determined by the GA yield the better system responses than those obtained by the conventional design method

  14. Estimating the impacts of wind power on power systems-summary of IEA Wind collaboration

    International Nuclear Information System (INIS)

    Holttinen, Hannele

    2008-01-01

    Adding wind power to power systems will have beneficial impacts by reducing the emissions of electricity production and reducing the operational costs of the power system as less fuel is consumed in conventional power plants. Wind power will also have a capacity value to a power system. However, possible negative impacts will have to be assessed to make sure that they will only offset a small part of the benefits and also to ensure the security of the power system operation. An international forum for the exchange of knowledge of power system impacts of wind power has been formed under the IEA Implementing Agreement on Wind Energy. The Task 'Design and Operation of Power Systems with Large Amounts of Wind Power' is analyzing existing case studies from different power systems. There are a multitude of studies completed and ongoing related to the cost of wind integration. However, the results are not easy to compare. This paper describes the general issues of wind power impacts on power systems and presents a comparison of results from ten case studies on increased balancing needs due to wind power

  15. Critical Clearing Time and Wind Power in Small Isolated Power Systems Considering Inertia Emulation

    Directory of Open Access Journals (Sweden)

    Elías Jesús Medina-Domínguez

    2015-11-01

    Full Text Available The stability and security of small and isolated power systems can be compromised when large amounts of wind power enter them. Wind power integration depends on such factors as power generation capacity, conventional generation technology or grid topology. Another issue that can be considered is critical clearing time (CCT. In this paper, wind power and CCT are studied in a small isolated power system. Two types of wind turbines are considered: a squirrel cage induction generator (SCIG and a full converter. Moreover, the full converter wind turbine’s inertia emulation capability is considered, and its impact on CCT is discussed. Voltage is taken into account because of its importance in power systems of this kind. The study focuses on the small, isolated Lanzarote-Fuerteventura power system, which is expected to be in operation by 2020.

  16. TS Seminar: Overview of Fermilab’s Power Distribution System

    CERN Multimedia

    CERN. Geneva

    2006-01-01

    A 27.5 km2 (6800 acre) site is powered by two 345 kV, two 34.5 kV, one 12.4 kV and five 7.2 kV lines. The talk gives an overview of Fermilab’s power distribution system with emphasis on accelerator power. The accelerator power distribution system provides 13.8 kV power to all accelerators and conventional loads. Design criteria, design features and operational experience are given.Organiser(s): F. Rodriguez-Mateos & Emmanuel Tsesmelis

  17. Power fluctuation reduction methodology for the grid-connected renewable power systems

    Science.gov (United States)

    Aula, Fadhil T.; Lee, Samuel C.

    2013-04-01

    This paper presents a new methodology for eliminating the influence of the power fluctuations of the renewable power systems. The renewable energy, which is to be considered an uncertain and uncontrollable resource, can only provide irregular electrical power to the power grid. This irregularity creates fluctuations of the generated power from the renewable power systems. These fluctuations cause instability to the power system and influence the operation of conventional power plants. Overall, the power system is vulnerable to collapse if necessary actions are not taken to reduce the impact of these fluctuations. This methodology aims at reducing these fluctuations and makes the generated power capability for covering the power consumption. This requires a prediction tool for estimating the generated power in advance to provide the range and the time of occurrence of the fluctuations. Since most of the renewable energies are weather based, as a result a weather forecast technique will be used for predicting the generated power. The reduction of the fluctuation also requires stabilizing facilities to maintain the output power at a desired level. In this study, a wind farm and a photovoltaic array as renewable power systems and a pumped-storage and batteries as stabilizing facilities are used, since they are best suitable for compensating the fluctuations of these types of power suppliers. As an illustrative example, a model of wind and photovoltaic power systems with battery energy and pumped hydro storage facilities for power fluctuation reduction is included, and its power fluctuation reduction is verified through simulation.

  18. Impact of wind power in autonomous power systems—power fluctuations—modelling and control issues

    DEFF Research Database (Denmark)

    Margaris, Ioannis D.; Hansen, Anca Daniela; Cutululis, Nicolaos Antonio

    2011-01-01

    for diesel and steam generation plants are applied. The power grid, including speed governors, automatic voltage regulators, protection system and loads is modelled in the same platform. Results for different load and wind profile cases are being presented for the case study of the island Rhodes, in Greece......This paper describes a detailed modelling approach to study the impact of wind power fluctuations on the frequency control in a non-interconnected system with large-scale wind power. The approach includes models for wind speed fluctuations, wind farm technologies, conventional generation...... technologies, power system protection and load. Analytical models for wind farms with three different wind turbine technologies, namely Doubly Fed Induction Generator, Permanent Magnet Synchronous Generator and Active Stall Induction Generator-based wind turbines, are included. Likewise, analytical models...

  19. Towards 100% renewable energy systems: Uncapping power system flexibility

    International Nuclear Information System (INIS)

    Papaefthymiou, G.; Dragoon, Ken

    2016-01-01

    Relying almost entirely on energy from variable renewable resources such as wind and solar energy will require a transformation in the way power systems are planned and operated. This paper outlines the necessary steps in creating power systems with the flexibility needed to maintain stability and reliability while relying primarily on variable energy resources. These steps are provided in the form of a comprehensive overview of policies, technical changes, and institutional systems, organized in three development phases: an initial phase (penetration up to about 10%) characterized by relatively mild changes to conventional power system operations and structures; a dynamic middle phase (up to about 50% penetration) characterized by phasing out conventional generation and a concerted effort to wring flexibility from existing infrastructure; and the high penetration phase that inevitably addresses how power systems operate over longer periods of weeks or months when variable generation will be in either short supply, or in over-abundance. Although this transition is likely a decades-long and incremental process and depends on the specifics of each system, the needed policies, research, demonstration projects and institutional changes need to start now precisely because of the complexity of the transformation. The list of policy actions presented in this paper can serve as a guideline to policy makers on effectuating the transition and on tracking the preparedness of systems. - Highlights: •100% VRES systems: combined analysis of all related technical and policy challenges. •Transition elements: classification of the complete range of challenges in 9 elements. •Development regimes: policy actions in 3 VRES penetration regimes (low-medium-high). •Policies: comprehensive guideline and detailed presentation of policies per regime. •Roadmap: lists of actions per regime act as transition roadmap to 100% VRES systems.

  20. Optimal Siting and Sizing of Energy Storage System for Power Systems with Large-scale Wind Power Integration

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Huang, Shaojun

    2015-01-01

    This paper proposes algorithms for optimal sitingand sizing of Energy Storage System (ESS) for the operationplanning of power systems with large scale wind power integration.The ESS in this study aims to mitigate the wind powerfluctuations during the interval between two rolling Economic......Dispatches (EDs) in order to maintain generation-load balance.The charging and discharging of ESS is optimized consideringoperation cost of conventional generators, capital cost of ESSand transmission losses. The statistics from simulated systemoperations are then coupled to the planning process to determinethe...

  1. Scheduling and resource allocation of non-conventional power systems via multi level approach

    Energy Technology Data Exchange (ETDEWEB)

    Fahmy, F H [National Research Center, Cairo (Egypt). Electronics Research Inst.

    1996-12-31

    The objective of article is to propose a design technique wit a new economic dispatch analysis. This analysis are used the combined hierarchical approach and N.L. programming. There are three different energy sources which can be used to feed a remote area in Egypt desert: Wind source, PV and Diesel engine. The two subsources are considered here as: Batteries and water Basin: The load demand is to feed the suitable electric energy need for irrigation and domestic services. The optimization problem is composed of set of goals with set of constraints i.e. a multi objective functions system had been studied as a large scale system. Using the developed technique, the complicated stochastic system can be transformed into a simple deterministic scale system for simplicity. The use of developed technique constitute a more forceful approach to find the minimum cost operating point with maximizing the total electric energy generated form the three energy sources. The method also gives greater flexibility in the selection of constraints, permitting the use of equality constraints as well as inequality one. (author)

  2. Scheduling and resource allocation of non-conventional power systems via multi level approach

    Energy Technology Data Exchange (ETDEWEB)

    Fahmy, F.H. [National Research Center, Cairo (Egypt). Electronics Research Inst.

    1995-12-31

    The objective of article is to propose a design technique wit a new economic dispatch analysis. This analysis are used the combined hierarchical approach and N.L. programming. There are three different energy sources which can be used to feed a remote area in Egypt desert: Wind source, PV and Diesel engine. The two subsources are considered here as: Batteries and water Basin: The load demand is to feed the suitable electric energy need for irrigation and domestic services. The optimization problem is composed of set of goals with set of constraints i.e. a multi objective functions system had been studied as a large scale system. Using the developed technique, the complicated stochastic system can be transformed into a simple deterministic scale system for simplicity. The use of developed technique constitute a more forceful approach to find the minimum cost operating point with maximizing the total electric energy generated form the three energy sources. The method also gives greater flexibility in the selection of constraints, permitting the use of equality constraints as well as inequality one. (author)

  3. Scheduling and resource allocation of non-conventional power systems via multi level approach

    International Nuclear Information System (INIS)

    Fahmy, F.H.

    1995-01-01

    The objective of article is to propose a design technique wit a new economic dispatch analysis. This analysis are used the combined hierarchical approach and N.L. programming. There are three different energy sources which can be used to feed a remote area in Egypt desert: Wind source, PV and Diesel engine. The two subsources are considered here as: Batteries and water Basin: The load demand is to feed the suitable electric energy need for irrigation and domestic services. The optimization problem is composed of set of goals with set of constraints i.e. a multi objective functions system had been studied as a large scale system. Using the developed technique, the complicated stochastic system can be transformed into a simple deterministic scale system for simplicity. The use of developed technique constitute a more forceful approach to find the minimum cost operating point with maximizing the total electric energy generated form the three energy sources. The method also gives greater flexibility in the selection of constraints, permitting the use of equality constraints as well as inequality one. (author)

  4. Some comments about the comparison between a conventional and a solar powered absorption refrigeration system

    International Nuclear Information System (INIS)

    Corbella, O.D.; Garibotti, C.R.

    1983-08-01

    Two statements about the performance of solar refrigeration systems are discussed. First, concepts of efficiency and coefficient of performance are studied. Second, the influence of inflation and rise of fuel prices are considered, in relation to the comparison between solar and conventional refrigeration systems. (author)

  5. Generic 12-Bus Test System for Wind Power Integration Studies

    DEFF Research Database (Denmark)

    Adamczyk, Andrzej Grzegorz; Altin, Müfit; Göksu, Ömer

    2012-01-01

    , inertial response, frequency control, damping of electromechanical oscillations, balanced and unbalanced fault management, etc. Hence, the power system components: conventional power plants with controls, transmission lines, transformers and loads should be represented accurately to achieve realistic power......High wind power penetration levels into power systems requires an appropriate power system model when assessing impact on the overall system stability. The model should capture the wide range of dynamics related to the wind integration studies, such as voltage control, synchronizing power control...... system characteristics. Additionally, the power system model should be simple and computationally manageable in order to simulate multiple scenarios with different control parameters in a reasonable time. In this paper, a generic power system model is presented in order to comprehend the wind integration...

  6. Stability and control of wind farms in power systems

    Energy Technology Data Exchange (ETDEWEB)

    Jauch, C.

    2006-10-15

    The Ph.D. project 'Stability and Control of Wind Farms in Power Systems' deals with some selected problems related to wind power in power systems. With increasing wind power penetration, wind turbines substitute the power production of conventional power plants. Therefore, wind turbines also have to take over the power system stabilisation and control tasks, that were traditionally carried out by conventional power plants. Out of the many aspects related to this problem, this project focuses on transient fault ride-through and power system stabilisation. The selection of turbine types considered in this project is limited to active-stall turbines and variable speed, variable pitch turbines with gearboxes and full-scale converter-connected synchronous generators. As a basis for the project, a study into the state of the art is conducted at the beginning of the project. Grid connection requirements that were in force, or published as drafts, at the time, and scientific literature related to the topic, are studied. The project is based on simulations of wind turbines in a power system simulations tool. Some of the models used in this project were readily available prior to the project; the development of others is part of the project. The most extensive modelling work deals with the design of the electrical part of the variable speed turbine and its controls. To simulate realistic grid operation the wind turbine models are connected to an aggregated model of the Nordic power system. For that purpose the Nordic power system model, which was available prior to the project, is extended with a realistic feeder configuration. It is commonly demanded from modern wind turbines, that they must not disconnect in case of transient faults. Therefore, controllers are designed that enable the two turbine types to ride through transient faults. With these transient fault controllers the wind turbines can stay connected to the grid, such that their generation capacity is

  7. On-line tuning of a fuzzy-logic power system stabilizer

    International Nuclear Information System (INIS)

    Hossein-Zadeh, N.; Kalam, A.

    2002-01-01

    A scheme for on-line tuning of a fuzzy-logic power system stabilizer is presented. firstly, a fuzzy-logic power system stabilizer is developed using speed deviation and accelerating power as the controller input variables. The inference mechanism of fuzzy-logic controller is represented by a decision table, constructed of linguistic IF-THEN rules. The Linguistic rules are available from experts and the design procedure is based on these rules. It assumed that an exact model of the plant is not available and it is difficult to extract the exact parameters of the power plant. Thus, the design procedure can not be based on an exact model. This is an advantage of fuzzy logic that makes the design of a controller possible without knowing the exact model of the plant. Secondly, two scaling parameters are introduced to tune the fuzzy-logic power system stabilizer. These scaling parameters are the outputs of another fuzzy-logic system, which gets the operating conditions of power system as inputs. These mechanism of tuning the fuzzy-logic power system stabilizer makes the fuzzy-logic power system stabilizer adaptive to changes in the operating conditions. Therefore, the degradation of the system response, under a wide range of operating conditions, is less compared to the system response with a fixed-parameter fuzzy-logic power system stabilizer and a conventional (linear) power system stabilizer. The tuned stabilizer has been tested by performing nonlinear simulations using a synchronous machine-infinite bus model. The responses are compared with a fixed parameters fuzzy-logic power system stabilizer and a conventional (linear) power system stabilizer. It is shown that the tuned fuzzy-logic power system stabilizer is superior to both of them

  8. Metabolisable energy values of some non-conventional feeding ...

    African Journals Online (AJOL)

    A metabolism trial was designed to evaluate dietary energy values (AME, AMEn, TME, TMEn) of eight readily available non-conventional feeding ingredients viz: cassava root meal (CRM); cassava leaf meal (CLM), mango leaf meal (MLM), shrimp waste meal (SWM), full-fat soyabean (FFSB), palm oil sludge (POS), corn cob ...

  9. Seasonal shifting of surplus renewable energy in a power system located in a cold region

    Directory of Open Access Journals (Sweden)

    Jorge Morel

    2014-10-01

    Full Text Available The Fukushima nuclear disaster in 2011 changed Japan's strategy for reducing CO2 emissions. The government is now placing more emphasis on the development of nonCO2-emitting distributed generation systems such as wind, solar, and tidal power to reduce greenhouse gas emissions and guarantee electricity supply in the case of a natural disaster. This paper proposes a strategy for the exploitation of wind, solar, and tidal resources in a cold region in Japan by utilizing surplus energy from the summer and spring during winter. It also aims to determine the most favorable energy mix of these renewable sources and storage system types. The study is performed by calculating hourly demand and renewable energy supply for the city in one year, which is based on actual data of demand, solar irradiation, wind speeds, and tidal current speeds. The costs of the components of the renewable power plants and storage systems are considered, and different proportions of generation outputs are evaluated with different types of storage systems. According to results, the configuration containing the hydrogen storage system using organic chemical hydride methylcyclohexane (OCHM is the most economical but is still more expensive than one using a conventional generation system. Moreover, we confirm that the cost of CO2 emissions is the key element for leveling the playing field between conventional and renewable generation from an economic perspective. The cost of CO2 emissions to public health as well as those costs related to the interruption of services during a catastrophe must be carefully calculated with other issues from conventional power projects to perform a precise comparative evaluation between both types of generation systems.

  10. Hybrid Genetic Algorithm Fuzzy-Based Control Schemes for Small Power System with High-Penetration Wind Farms

    Directory of Open Access Journals (Sweden)

    Mohammed Elsayed Lotfy

    2018-03-01

    Full Text Available Wind is a clean, abundant, and inexhaustible source of energy. However, wind power is not constant, as windmill output is proportional to the cube of wind speed. As a result, the generated power of wind turbine generators (WTGs fluctuates significantly. Power fluctuation leads to frequency deviation and voltage flicker inside the system. This paper presents a new methodology for controlling system frequency and power. Two decentralized fuzzy logic-based control schemes with a high-penetration non-storage wind–diesel system are studied. First, one is implemented in the governor of conventional generators to damp frequency oscillation, while the other is applied to control the pitch angle system of wind turbines to smooth wind output power fluctuations and enhance the power system performance. A genetic algorithm (GA is employed to tune and optimize the membership function parameters of the fuzzy logic controllers to obtain optimal performance. The effectiveness of the suggested controllers is validated by time domain simulation for the standard IEEE nine-bus three-generator test system, including three wind farms. The robustness of the power system is checked under normal and faulty operating conditions.

  11. Design and Test Plans for a Non-Nuclear Fission Power System Technology Demonstration Unit

    Science.gov (United States)

    Mason, Lee; Palac, Donald; Gibson, Marc; Houts, Michael; Warren, John; Werner, James; Poston, David; Qualls, Arthur Lou; Radel, Ross; Harlow, Scott

    2012-01-01

    A joint National Aeronautics and Space Administration (NASA) and Department of Energy (DOE) team is developing concepts and technologies for affordable nuclear Fission Power Systems (FPSs) to support future exploration missions. A key deliverable is the Technology Demonstration Unit (TDU). The TDU will assemble the major elements of a notional FPS with a non-nuclear reactor simulator (Rx Sim) and demonstrate system-level performance in thermal vacuum. The Rx Sim includes an electrical resistance heat source and a liquid metal heat transport loop that simulates the reactor thermal interface and expected dynamic response. A power conversion unit (PCU) generates electric power utilizing the liquid metal heat source and rejects waste heat to a heat rejection system (HRS). The HRS includes a pumped water heat removal loop coupled to radiator panels suspended in the thermal-vacuum facility. The basic test plan is to subject the system to realistic operating conditions and gather data to evaluate performance sensitivity, control stability, and response characteristics. Upon completion of the testing, the technology is expected to satisfy the requirements for Technology Readiness Level 6 (System Demonstration in an Operational and Relevant Environment) based on the use of high-fidelity hardware and prototypic software tested under realistic conditions and correlated with analytical predictions.

  12. Boiler feedwater quality improvement by replacing conventional pre-treatment with advanced membrane systems

    Energy Technology Data Exchange (ETDEWEB)

    Doll, Bernhard [Process Systems Pall GmbH, Dreieich (Germany). Marketing; Venkatadri, Ramraj [Pall Corporation, Port Washington, NY (United States). Global Marketing Energy

    2013-09-01

    Two case studies in different application fields highlight significant economical and operational improvements that were achieved by replacing conventional water treatment technologies by highly-sophisticated membrane systems. The first case study deals with boiler feedwater in a power plant, focusing on the challenges faced as well as the direct and indirect benefits gained by the new system within a utility station. The second case study deals with the conventional water treatment scheme for groundwater from 13 wells at a major oil sands facility. Operational performance as well as the cost improvements gained in both cases will be presented. (orig.)

  13. Electromagnetic compatibility (EMC) design guidelines for I and C systems for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Koo; Lee, Dong Young; Cha, Kyung Ho; Park, Joo Hyun; Lee, Ki Young [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-02-01

    This report describes the research results on Electromagnetic Compatibility technologies for I and C(Instrumentation and Control) systems for nuclear power plants. As the nuclear industries are adopting the digital equipment rather than the conventional analog type equipment for safety I and C systems as well as non-safety systems of nuclear power plants(NPPs), it is necessary to secure compatibility against EMI(electromagnetic interference) for the digital safety I and C systems. EMI qualification, identified as a regulatory compliance item by US NRC and Korean regulatory body, should be performed in accordance with appropriate standards, because the electromagnetic environment is regarded as one of the environmental factors possible to affect the safety functions. As a technical guide on this EMI issue, this report includes description of code and standards scheme, EMI qualification methods, noise reduction strategies, and survey on noise levels in nuclear power plants. 29 refs., 72 figs., 5 tabs. (Author)

  14. Application of pattern search method to power system security constrained economic dispatch with non-smooth cost function

    International Nuclear Information System (INIS)

    Al-Othman, A.K.; El-Naggar, K.M.

    2008-01-01

    Direct search methods are evolutionary algorithms used to solve optimization problems. (DS) methods do not require any information about the gradient of the objective function at hand while searching for an optimum solution. One of such methods is Pattern Search (PS) algorithm. This paper presents a new approach based on a constrained pattern search algorithm to solve a security constrained power system economic dispatch problem (SCED) with non-smooth cost function. Operation of power systems demands a high degree of security to keep the system satisfactorily operating when subjected to disturbances, while and at the same time it is required to pay attention to the economic aspects. Pattern recognition technique is used first to assess dynamic security. Linear classifiers that determine the stability of electric power system are presented and added to other system stability and operational constraints. The problem is formulated as a constrained optimization problem in a way that insures a secure-economic system operation. Pattern search method is then applied to solve the constrained optimization formulation. In particular, the method is tested using three different test systems. Simulation results of the proposed approach are compared with those reported in literature. The outcome is very encouraging and proves that pattern search (PS) is very applicable for solving security constrained power system economic dispatch problem (SCED). In addition, valve-point effect loading and total system losses are considered to further investigate the potential of the PS technique. Based on the results, it can be concluded that the PS has demonstrated ability in handling highly nonlinear discontinuous non-smooth cost function of the SCED. (author)

  15. Use of non-conventional tests for the diagnosis of brucellosis

    International Nuclear Information System (INIS)

    Biancifiori, F.

    1998-01-01

    A number of non-conventional tests to complement traditional diagnostic methods for Brucellosis were established and assessed in order to verify whether the adoption of a panel of methods combined to alternative sampling strategies would increase the possibility of detecting low levels of Brucella spp. antibodies or microorganisms. The diagnostic performance of each test was established by means of reference standards and compared with conventional screening and confirmatory tests under field conditions. Non-conventional tests assessed for detecting Brucella organisms included: an agglutination method using a monoclonal antibody for an early and specific detection of Brucella spp. from colonies, polymerase chain reaction (PCR) for detection of Brucella spp in raw milk. Methods for detecting Brucella spp. antibodies included an ELISA test applied to cow milk, evaluation of milk-ELISA test through repeated sampling and ELISA in milk for the diagnosis of ovine brucellosis. The adopted strategy of repeated milk testing in dairy cows using ELISA increased the chance of identification of positive animals. (author)

  16. A Stochastic Operational Planning Model for Smart Power Systems

    Directory of Open Access Journals (Sweden)

    Sh. Jadid

    2014-12-01

    Full Text Available Smart Grids are result of utilizing novel technologies such as distributed energy resources, and communication technologies in power system to compensate some of its defects. Various power resources provide some benefits for operation domain however, power system operator should use a powerful methodology to manage them. Renewable resources and load add uncertainty to the problem. So, independent system operator should use a stochastic method to manage them. A Stochastic unit commitment is presented in this paper to schedule various power resources such as distributed generation units, conventional thermal generation units, wind and PV farms, and demand response resources. Demand response resources, interruptible loads, distributed generation units, and conventional thermal generation units are used to provide required reserve for compensating stochastic nature of various resources and loads. In the presented model, resources connected to distribution network can participate in wholesale market through aggregators. Moreover, a novel three-program model which can be used by aggregators is presented in this article. Loads and distributed generation can contract with aggregators by these programs. A three-bus test system and the IEEE RTS are used to illustrate usefulness of the presented model. The results show that ISO can manage the system effectively by using this model

  17. Investigation of modeling and simulation on a PWR power conversion system with RELAP5

    International Nuclear Information System (INIS)

    Rui Gao; Yang Yanhua; Lin Meng; Yuan Minghao; Xie Zhengrui

    2007-01-01

    Based on the power conversion system of nuclear and conventional islands of Dayabay nuclear power station, this paper models the thermal-hydraulic systems for PWR by using the best-estimate program, RELAP5. To simulate the full-scope power conversion system, not only the reactor coolant system (RCP) of nuclear island, but also the main steam system (VVP), turbine steam and drain system (GPV), bypass system (GCT), feedwater system (FW), condensate extraction system (CEX), moisture separator reheater system (GSS), turbine-driven feedwater pump (APP), low-pressure and high-pressure feedwater heater systems (ABP and AHP) of conventional island are considered and modeled. A comparison between the simulated results and the actual data of reactor under full-power demonstrates a fine match for Dayabay, and also manifests the feasibility in simulating full-scope power conversion system of PWR with RELAP5. (author)

  18. NON-CONVENTIONAL PET NUCLIDES: PRODUCTION AND IMAGING

    OpenAIRE

    Laforest, Richard

    2015-01-01

    Abstract Medical cyclotrons are now commonly used for the production of PET nuclides by the (pn) reaction. These devices are typically capable of delivering 10-15 MeV protons beams at sufficiently high intensity for timely production of β+ decaying nuclides. Non-conventional PET nuclides have emerged recently and offers new opportunities for diagnostic and therapy drug discovery. In this paper, we will review the production capabilities for such nuclides at Washington University Medical Schoo...

  19. Short-Term and Medium-Term Reliability Evaluation for Power Systems With High Penetration of Wind Power

    DEFF Research Database (Denmark)

    Ding, Yi; Singh, Chanan; Goel, Lalit

    2014-01-01

    reliability evaluation techniques for power systems are well developed. These techniques are more focused on steady-state (time-independent) reliability evaluation and have been successfully applied in power system planning and expansion. In the operational phase, however, they may be too rough......The expanding share of the fluctuating and less predictable wind power generation can introduce complexities in power system reliability evaluation and management. This entails a need for the system operator to assess the system status more accurately for securing real-time balancing. The existing...... an approximation of the time-varying behavior of power systems with high penetration of wind power. This paper proposes a time-varying reliability assessment technique. Time-varying reliability models for wind farms, conventional generating units, and rapid start-up generating units are developed and represented...

  20. Non-power application as an entry point to nuclear power program

    International Nuclear Information System (INIS)

    Nahrul Khair Alang Md Rashid

    2009-01-01

    Nuclear power is usually viewed as the flagship of nuclear technology. A nuclear power plant complex, visible and prominence, is iconic of the technology. That image makes its presence common knowledge to the extent that nuclear technology is equated almost totally with nuclear power by the general public. The downside of this visibility is that it becomes easy target in public misinformation programs. The non-power applications however are not visible, and devoid of icon. The non-power applications, therefore, can grow quite smoothly, attracting only little attention in the negative and in the positive senses. According to a study conducted in the USA in 2000 and in Japan in 2002, the socio-economic impact of non-power and power applications of nuclear technology are comparable. Involvement in non-power applications can be a good grounding for moving into power applications. This paper discusses the non-power nuclear technology applications and in what manner it can serve to prepare the introduction of nuclear power program. (Author)

  1. Addressing On-Chip Power Converstion and Dissipation Issues in Many-Core System-on-a-Chip Based on Conventional Silicon and Emerging Nanotechnologies

    Science.gov (United States)

    Ashenafi, Emeshaw

    Integrated circuits (ICs) are moving towards system-on-a-chip (SOC) designs. SOC allows various small and large electronic systems to be implemented in a single chip. This approach enables the miniaturization of design blocks that leads to high density transistor integration, faster response time, and lower fabrication costs. To reap the benefits of SOC and uphold the miniaturization of transistors, innovative power delivery and power dissipation management schemes are paramount. This dissertation focuses on on-chip integration of power delivery systems and managing power dissipation to increase the lifetime of energy storage elements. We explore this problem from two different angels: On-chip voltage regulators and power gating techniques. On-chip voltage regulators reduce parasitic effects, and allow faster and efficient power delivery for microprocessors. Power gating techniques, on the other hand, reduce the power loss incurred by circuit blocks during standby mode. Power dissipation (Ptotal = Pstatic and Pdynamic) in a complementary metal-oxide semiconductor (CMOS) circuit comes from two sources: static and dynamic. A quadratic dependency on the dynamic switching power and a more than linear dependency on static power as a form of gate leakage (subthreshold current) exist. To reduce dynamic power loss, the supply power should be reduced. A significant reduction in power dissipation occurs when portions of a microprocessor operate at a lower voltage level. This reduction in supply voltage is achieved via voltage regulators or converters. Voltage regulators are used to provide a stable power supply to the microprocessor. The conventional off-chip switching voltage regulator contains a passive floating inductor, which is difficult to be implemented inside the chip due to excessive power dissipation and parasitic effects. Additionally, the inductor takes a very large chip area while hampering the scaling process. These limitations make passive inductor based on

  2. Optimized efficiency of all-electric ships by dc hybrid power systems

    Science.gov (United States)

    Zahedi, Bijan; Norum, Lars E.; Ludvigsen, Kristine B.

    2014-06-01

    Hybrid power systems with dc distribution are being considered for commercial marine vessels to comply with new stringent environmental regulations, and to achieve higher fuel economy. In this paper, detailed efficiency analysis of a shipboard dc hybrid power system is carried out. An optimization algorithm is proposed to minimize fuel consumption under various loading conditions. The studied system includes diesel engines, synchronous generator-rectifier units, a full-bridge bidirectional converter, and a Li-Ion battery bank as energy storage. In order to evaluate potential fuel saving provided by such a system, an online optimization strategy for fuel consumption is implemented. An Offshore Support Vessel (OSV) is simulated over different operating modes using the online control strategy. The resulted consumed fuel in the simulation is compared to that of a conventional ac power system, and also a dc power system without energy storage. The results show that while the dc system without energy storage provides noticeable fuel saving compared to the conventional ac system, optimal utilization of the energy storage in the dc system results in twice as much fuel saving.

  3. Coherent states for oscillators of non-conventional statistics

    International Nuclear Information System (INIS)

    Dao Vong Duc; Nguyen Ba An

    1998-12-01

    In this work we consider systematically the concept of coherent states for oscillators of non-conventional statistics - parabose oscillator, infinite statistics oscillator and generalised q-deformed oscillator. The expressions for the quadrature variances and particle number distribution are derived and displayed graphically. The obtained results show drastic changes when going from one statistics to another. (author)

  4. Wind energy systems solutions for power quality and stabilization

    CERN Document Server

    Ali, Mohd Hasan

    2012-01-01

    Unlike conventional power plants, wind plants emit no air pollutants or greenhouse gases--and wind energy is a free, renewable resource. However, the induction machines commonly used as wind generators have stability problems similar to the transient stability of synchronous machines. To minimize power, frequency, and voltage fluctuations caused by network faults or random wind speed variations, control mechanisms are necessary. Wind Energy Systems: Solutions for Power Quality and Stabilization clearly explains how to solve stability and power quality issues of wind generator systems. Covering

  5. Power conditioning system for a nuclear reactor

    International Nuclear Information System (INIS)

    Higashigawa, Yuichi; Joge, Toshio.

    1981-01-01

    Purpose: To provide a power conditioning system for a BWR type reactor which has a function to be automatically operated within a range that the relationship between the heat power of the reactor and the electric power of an electric generator does not lose the safety of fuel by eliminating the unnecessary fluctuation of the power of the reactor. Constitution: A load request error signal fed from a conventional turbine control system to recirculation flow regulator is eliminated, and a reactor power conditioning system is newly provided, to which an electric generator power signal, a reactor average power area monitor signal and a load request signal are inputted. Thus, the load request signal is compared directly with the electric power of the electric generator, the recirculation flow rate is controlled by the compared result, and whether the correlation between the heat power of the reqctor and the electric power of the generator satisfies the correlation determined to prove the safety of fuel or not is checked. If this correlation is satisfied, the recirculation flow rate is merely automatically controlled. (Yoshino, Y.)

  6. Aggregated Wind Park Models for Analysing Power System Dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Poeller, Markus; Achilles, Sebastian [DIgSILENT GmbH, Gomaringen (Germany)

    2003-11-01

    The increasing amount of wind power generation in European power systems requires stability analysis considering interaction between wind-farms and transmission systems. Dynamics introduced by dispersed wind generators at the distribution level can usually be neglected. However, large on- and offshore wind farms have a considerable influence to power system dynamics and must definitely be considered for analyzing power system dynamics. Compared to conventional power stations, wind power plants consist of a large number of generators of small size. Therefore, representing every wind generator individually increases the calculation time of dynamic simulations considerably. Therefore, model aggregation techniques should be applied for reducing calculation times. This paper presents aggregated models for wind parks consisting of fixed or variable speed wind generators.

  7. Non-conventional antiphospholipid antibodies in patients with clinical obstetrical APS: Prevalence and treatment efficacy in pregnancies.

    Science.gov (United States)

    Mekinian, Arsène; Bourrienne, Marie-Charlotte; Carbillon, Lionel; Benbara, Amélie; Noémie, Abisror; Chollet-Martin, Sylvie; Tigaizin, Ahmed; Montestruc, Francois; Fain, Olivier; Nicaise-Roland, Pascale

    2016-10-01

    To describe the prevalence of non-conventional APL in patients with obstetrical APS without conventional APL and the impact of treatment on pregnancy outcome. Patients with clinical obstetrical criteria were tested for anti-phosphatidylethanolamine (aPE) IgG/M, anti-prothrombin/phosphatidylserine (anti-PS/PT) IgG/M, and anti-annexin V IgG. Pregnancy losses rates were compared between APS, non-conventional APS, and non-APL and in untreated pregnancies to treated ones for each group. Using the cutoffs (ROC), 65/96 (68%) patients have been considered as non-conventional APS and compared to 83 APS and 31 patients without APL. The obstetrical history in non-conventional APS did not differ in comparison to confirmed APS. The frequencies of anti-annexin V IgG antibodies tended to be more frequent in non-conventional APS (88% versus 73%; p = 0.06), and those of anti-PE IgG and M were similar. The anti-PS/PT IgG and M antibodies were more frequent in confirmed APS than in non-conventional APS (63% and 37% versus 4% and 5%, respectively, p APS were compared with 81 pregnancies of confirmed APS and 132 pregnancies from non-APL group. Out of 474, 136 (29%) patients have been treated during pregnancies, and treatment significantly increased the rate of live birth (26% in untreated versus 72% in treated pregnancies, p APS and non-conventional APS, with odds ratio at 3.3 (95% CI: 1.8-6.1) and 6.9 (95% CI: 3.9-12.3) (p = 0.49) and significantly more important for the 2 APS groups pooled versus non-APL group [OR at 1.9 (95% CI: 1.1-3.5) for non-APL group versus 5.3 (95% CI: 3.5-8.1) for APS groups, p = 0.0025]. In this study, 68% of patients with clinical criteria for obstetrical APS seronegative for conventional APL have non-conventional APL. These patients have a significant decrement of pregnancy losses if they receive treatment for APS during their pregnancy. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Non-conventional plasma assisted catalysts for diesel exhaust treatment. A case study

    International Nuclear Information System (INIS)

    Rajanikanth, B.S.; Srinivas Kumar, P.K.; Ravi, V.

    2002-01-01

    The author reports the application of pulse discharges along with catalysts in treating the exhaust gas at higher temperatures. In the present work, a plasma reactor, filled with catalysts, called as plasma catalytic reactor, is studied for removal of oxides of nitrogen, total hydrocarbons and carbon monoxide. The experiments are conducted on an actual diesel engine exhaust at no-load and at different temperatures starting from room temperature to 300 degree C. The removal efficiencies of these pollutants are studied. The experiments are carried out with both conventional and non-conventional catalysts. The idea is to explore the pollutant removal efficiency characteristics by non-conventional catalysts. The efficiency results are compared with that of conventional catalysts. The experiments are carried out at a constant pulse repetition rate of 120 pps. Both pellet and honeycomb type catalysts are used in the study

  9. From conventional software based systems to knowledge based systems

    International Nuclear Information System (INIS)

    Bologna, S.

    1995-01-01

    Even if todays nuclear power plants have a very good safety record, there is a continuous search for still improving safety. One direction of this effort address operational safety, trying to improve the handling of disturbances and accidents partly by further automation, partly by creating a better control room environment, providing the operator with intelligent support systems to help in the decision making process. Introduction of intelligent computerised operator support systems has proved to be an efficient way of improving the operators performance. A number of systems have been developed worldwide, assisting in tasks like process fault detection and diagnosis, selection and implementation of proper remedial actions. Unfortunately, the use of Knowledge Based Systems (KBSs), introduces a new dimension to the problem of the licensing process. KBSs, despite the different technology employed, are still nothing more than a computer program. Unfortunately, quite a few people building knowledge based systems seem to ignore the many good programming practices that have evolved over the years for producing traditional computer programs. In this paper the author will try to point out similarities and differences between conventional software based systems, and knowledge based systems, introducing also the concept of model based reasoning. (orig.) (25 refs., 2 figs.)

  10. Energy Storage in Power System Operation: The Power Nodes Modeling Framework

    DEFF Research Database (Denmark)

    Heussen, Kai; Koch, Stephan; Ulbig, Andreas

    2010-01-01

    for designing operation strategies for power systems based on ubiquitous energy storage, for example to buer non-dispatchable generation, as well as for the evaluation of the operational performance in terms of energy eciency, reliability and cost. After introducing the modeling approach and a categorization......In this paper, a novel concept for the description of energy storage in power systems with dispatchable and non-dispatchable generators and loads is presented. It is based on a system-perspective consideration of energy storage, generation and consumption. This means that grid-relevant aspects...

  11. Feasibility study and functional requirements for a digital non-conventional literature system at INIS and Member Sites

    International Nuclear Information System (INIS)

    Hendley, T.; Dixon, R.

    1993-03-01

    The aim of any Non-Conventional Literature (NCL) system will be to improve the service INIS provides to members, reducing the operational cost of administering the NCL service by the streamlining of procedures, allowing INIS to provide NCL to members using media relevant to the needs of members and positioning INIS so that as a member's needs change these needs can be catered for. Specific functional requirements include the receipt and checking of NCL documents and bibliographic data, conversion of received NCL into digital image form accessed by an image index database referenced alongside the existing bibliographic database and output of NCL to digital interchange/distribution media in addition to microfiche and possibly paper. The quality of service to members in terms of document quality and turn around time must be at least maintained. The study was undertaken by Cimtech consultants between December 1992 and March 1993. Approximate costs and benefits of implementing a digital NCL system were identified. Some outstanding issues need to be resolved. This could include a pilot system being introduced which would allow requirements to be defined more fully and operational experience to be gained. (Author)

  12. Electric Vehicles Integration in the Electric Power System with Intermittent Energy Sources - The Charge/Discharge infrastructure

    DEFF Research Database (Denmark)

    Marra, Francesco

    The replacement of conventional fuelled vehicles with electric vehicles (EVs) is going to increase in the coming years, following the trend seen for renewable energy sources (RES), as photovoltaic (PV) and wind power. In this scenario, the electric power systems in Europe are going to accommodate...... increased levels of non-dispatchable and fluctuating energy sources, as well as additional power demand due to EV charging. If the charging of EVs can be intelligently managed, several advantages can be offered to the power system. How useful coordinated EV charging can be, in combination with RES...... and the power levels needed. Furthermore, during EV coordination, a number of nonlinearities and battery ageing issues should be taken into account, to ensure a correct EV coordination and to preserve the EV battery lifetime. The third part of this research exploits the use of EV load coordination as an energy...

  13. Substitutes or Complements? Diagnosis and Treatment with non-Conventional and Conventional Medicine

    Directory of Open Access Journals (Sweden)

    Aida Isabel Tavares

    2015-04-01

    Full Text Available Background Portugal has a strong tradition of conventional western healthcare. So it provides a natural case study for the relationship between Complementary/Alternative Medicine (CAM and Western Medicine (WM. This work aims to test the relationship between CAM and WM users in the diagnosis and treatment stages and to estimate the determinants of CAM choice. Methods The forth Portuguese National Health Survey is employed to estimate two single probit models and obtain the correlation between the consumption of CAM and WM medicines in the diagnosis and treatment stages. Results Firstly, both in the diagnosis and the treatment stage, CAM and WM are seen to be complementary choices for individuals. Secondly, self-medication also shows complementarity with the choice of CAM treatment. Thirdly, education has a non-linear relationship with the choice of CAM. Finally, working status, age, smoking and chronic disease are determinant factors in the decision to use CAM. Conclusion The results of this work are relevant to health policy-makers and for insurance companies. Patients need freedom of choice and, for the sake of safety and efficacy of treatment, WM and CAM healthcare ought to be provided in a joint and integrated health system.

  14. Grid-friendly wind power systems based on the synchronverter technology

    International Nuclear Information System (INIS)

    Zhong, Qing-Chang; Ma, Zhenyu; Ming, Wen-Long; Konstantopoulos, George C.

    2015-01-01

    Highlights: • A grid-friendly wind power system that uses the synchronverter technology is proposed. • Both the rotor-side and the grid-side converters act as synchronverters. • The complete generator–motor–generator system improves the performance under grid faults. • Real-time digital simulation results verify the effectiveness of the proposed method. - Abstract: Back-to-back PWM converters are becoming a realistic alternative to conventional converters in high-power wind power applications. In this paper, a control strategy based on the synchronverter technology is proposed for back-to-back PWM converters. Both converters are run as synchronverters, which are mathematically equivalent to the conventional synchronous generators. The rotor-side converter is responsible for maintaining the DC link voltage and the grid-side converter is responsible for the maximum power point tracking (MPPT). As the two converters are operated using the synchronverter technology, the formed wind power system becomes more friendly to the grid. Extensive real-time digital simulation results are presented to verify the effectiveness of the proposed method under normal operation and grid-fault scenarios

  15. Wind Generation Participation in Power System Frequency Response: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, Vahan; Zhang, Yingchen

    2017-01-01

    The electrical frequency of an interconnected power system must be maintained close its nominal level at all times. Excessive under- and overfrequency excursions can lead to load shedding, instability, machine damage, and even blackouts. There is a rising concern in the electric power industry in recent years about the declining amount of inertia and primary frequency response (PFR) in many interconnections. This decline may continue due to increasing penetrations of inverter-coupled generation and the planned retirements of conventional thermal plants. Inverter-coupled variable wind generation is capable of contributing to PFR and inertia with a response that is different from that of conventional generation. It is not yet entirely understood how such a response will affect the system at different wind power penetration levels. The modeling work presented in this paper evaluates the impact of wind generation's provision of these active power control strategies on a large, synchronous interconnection. All simulations were conducted on the U.S. Western Interconnection with different levels of instantaneous wind power penetrations (up to 80%). The ability of wind power plants to provide PFR - and a combination of synthetic inertial response and PFR - significantly improved the frequency response performance of the system.

  16. Grid-Connection Half-Bridge PV Inverter System for Power Flow Controlling and Active Power Filtering

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-01-01

    Full Text Available A half-bridge photovoltaic (PV system is proposed, which can not only deal with bidirectional power flowing but also improve power quality. According to varying insolation, the system conditions real power for dc and ac loads to accommodate different amounts of PV power. Furthermore, the system eliminates current harmonics and improves power factor simultaneously. As compared with conventional PV inverter, the total number of active switches and current sensors can be reduced so that its cost is lower significantly. For current command determination, a linear-approximation method (LAM is applied to avoid the complicated calculation and achieve the maximum power point tracking (MPPT feature. For current controlling, a direct-source-current-shaping (DSCS algorithm is presented to shape the waveform of line current. Simulation results and practical measurements also demonstrate the feasibility of the proposed half-bridge PV system.

  17. QFT Framework for Robust Tuning of Power System Stabilizers

    DEFF Research Database (Denmark)

    Alavi, Seyyed Mohammad Mahdi; Izadi-Zamanabadi, Roozbeh

    2005-01-01

    This paper discusses the use of conventional quantitative feedback design for Power System Stabilizer (PSS). An appropriate control structure of the PSS that is directly applicable to PSS, is described. Two desired performances are also proposed in order to achieve an overall improvement in damping...... and robustness. The efficiency of the proposed method is demonstrated on Single Machine Infinite Bus (SMIB) power system with level of uncertainty....

  18. Integration of stochastic generation in power systems

    NARCIS (Netherlands)

    Papaefthymiou, G.; Schavemaker, P.H.; Sluis, van der L.; Kling, W.L.; Kurowicka, D.; Cooke, R.M.

    2006-01-01

    Stochastic generation, i.e., electrical power production by an uncontrolled primary energy source, is expected to play an important role in future power systems. A new power system structure is created due to the large-scale implementation of this small-scale, distributed, non-dispatchable

  19. Energy storage in future power systems

    DEFF Research Database (Denmark)

    Rasmussen, Claus Nygaard; Østergaard, Jacob; Divya, K. C.

    2011-01-01

    Most sources of renewable power are characterised by uncontrollable and chaotic variations in power output. We here look at how energy storage may benefit renewable power generation by making it available in periods with little or no intermittent generation and thereby prevent additional conventi......Most sources of renewable power are characterised by uncontrollable and chaotic variations in power output. We here look at how energy storage may benefit renewable power generation by making it available in periods with little or no intermittent generation and thereby prevent additional...... conventional generation form being used. In addition to this, one of the strongest concerns in relation to renewable power is the instability in the electric power system that it may introduce as a result of large and relatively fast power fluctuations. An additional benefit of energy storage is therefore its...

  20. Economy analysis on vertical layout of conventional island of nuclear power plant

    International Nuclear Information System (INIS)

    Wang Xuefeng; Liu Xiaoyun; Liu Jinwei

    2011-01-01

    This paper briefly introduces the aboveground layout scheme and integral sinking layout scheme of conventional island of nuclear power plants. Technological-economic analysis formula are given, as a result, main factors influencing scheme selection is obtained. Determination of the layout scheme selection and optimization direction through the curve between the accumulative NPV and related factors is brought forward. The paper carries out the technological-economic comparison to the two schemes referred to a 1000 MW level nuclear power project as the example, getting the curve between the accumulative NPV and the plant ground elevation, and offering the method of selecting the vertical layout scheme of conventional island and vertical layout optimization direction. (authors)

  1. Awareness and use of non-conventional tobacco products among U.S. students, 2012.

    Science.gov (United States)

    Wang, Baoguang; King, Brian A; Corey, Catherine G; Arrazola, René A; Johnson, Sarah E

    2014-08-01

    Increasing diversity of the tobacco product landscape, including electronic cigarettes (e-cigarettes), hookah, snus, and dissolvable tobacco products (dissolvables), raises concerns about the public health impact of these non-conventional tobacco products among youth. This study assessed awareness, ever use, and current use of non-conventional tobacco products among U.S. students in 2012, overall and by demographic and tobacco use characteristics. Data from the 2012 National Youth Tobacco Survey, a nationally representative survey of U.S. middle and high school students, were analyzed in 2013. Prevalence of awareness, ever use, and current use of e-cigarettes, hookah, snus, and dissolvables were calculated overall and by sex, school level, race/ethnicity, and conventional tobacco product use, including cigarettes, cigars, or smokeless tobacco (chewing tobacco, snuff, or dip). Overall, 50.3% of students were aware of e-cigarettes; prevalence of ever and current use of e-cigarettes was 6.8% and 2.1%, respectively. Awareness of hookah was 41.2% among all students, and that of ever and current use were 8.9% and 3.6%, respectively. Overall awareness; ever; and current use of snus (32%, 5.3%, 1.7%, respectively) and dissolvables (19.3%, 2.0%, 0.7%, respectively) were generally lower than those of e-cigarettes or hookah. Conventional tobacco product users were more likely to be aware of and to use non-conventional tobacco products. Many U.S. students are aware of and use non-conventional tobacco products. Evidence-based interventions should be implemented to prevent and reduce all tobacco use among youth. Published by Elsevier Inc.

  2. Desain Power System Stabilizer Berbasis Fuzzy Tipe-2 untuk Perbaikan Stabilitas Mesin Tunggal

    Directory of Open Access Journals (Sweden)

    I Made Ginarsa

    2018-04-01

    Full Text Available The growth of type-2 fuzzy logic system is penetrating electric power system field, especially on electric power system control sub-field in order to simplify the design of power system stabilizer (PSS. Traditionally, the function of conventional PSS is to damp rotor oscillation when a disturbance occurred due to transmission configuration or/and loading changes. However, the response of conventional PSS is slow with long settling time and high peak overshoot. To cover this problem, PSS based on type-2 fuzzy logic system (PFT2 is proposed. Simulation results show that the PFT2 is able to improve the stability of a single machine with 3 scenarios on transmission configuration and loading variation. The PFT2 gives shorter settling time for all scenarios and loading variation than the settling time of conventional PSS. Also, the peak overshoot of the PFT2 is smaller than the peak overshoot of the other competing PSS.

  3. Heat engine development for solar thermal power systems

    Science.gov (United States)

    Pham, H. Q.; Jaffe, L. D.

    The parabolic dish solar collector systems for converting sunlight to electrical power through a heat engine will, require a small heat engine of high performance long lifetime to be competitive with conventional power systems. The most promising engine candidates are Stirling, high temperature Brayton, and combined cycle. Engines available in the current market today do not meet these requirements. The development of Stirling and high temperature Brayton for automotive applications was studied which utilizes much of the technology developed in this automotive program for solar power engines. The technical status of the engine candidates is reviewed and the components that may additional development to meet solar thermal system requirements are identified.

  4. Nuclear or conventional power for surface combatant ships: Department of the Navy. Report to the Congress

    International Nuclear Information System (INIS)

    1977-01-01

    GAO reviewed the controversy over whether the Navy's major surface combatant ships should be all nuclear powered, all conventionally powered, or a mix of both. Nuclear ships are more capable but cost more and their relative cost-effectiveness cannot be measured because Navy analysts cannot quantify many benefits of nuclear power. The Congress, in reviewing Navy shipbuilding plans for surface combatant ships, should be cognizant that buying only conventional ships will maximize naval firepower; buying only nuclear ships will provide mobility and greater freedom from logistics support; and buying a mix is a third option providing, to varying degrees, the advantages and disadvantages of the all-nuclear and all-conventional options

  5. A Novel Supervisory Control Algorithm to Improve the Performance of a Real-Time PV Power-Hardware-In-Loop Simulator with Non-RTDS

    Directory of Open Access Journals (Sweden)

    Dae-Jin Kim

    2017-10-01

    Full Text Available A programmable direct current (DC power supply with Real-time Digital Simulator (RTDS-based photovoltaic (PV Power Hardware-In-the-Loop (PHIL simulators has been used to improve the control algorithm and reliability of a PV inverter. This paper proposes a supervisory control algorithm for a PV PHIL simulator with a non-RTDS device that is an alternative solution to a high-cost PHIL simulator. However, when such a simulator with the conventional algorithm which is used in an RTDS is connected to a PV inverter, the output is in the transient state and it makes it impossible to evaluate the performance of the PV inverter. Therefore, the proposed algorithm controls the voltage and current target values according to constant voltage (CV and constant current (CC modes to overcome the limitation of the Computing Unit and DC power supply, and it also uses a multi-rate system to account for the characteristics of each component of the simulator. A mathematical model of a PV system, programmable DC power supply, isolated DC measurement device, and Computing Unit are integrated to form a real-time processing simulator. Performance tests are carried out with a commercial PV inverter and prove the superiority of this proposed algorithm against the conventional algorithm.

  6. Comprehensive Power Losses Model for Electronic Power Transformer

    DEFF Research Database (Denmark)

    Yue, Quanyou; Li, Canbing; Cao, Yijia

    2018-01-01

    and considering the impact of the non-unity power factor and the three-phase unbalanced current, the overall power losses in the distribution network when using the EPT to replace the conventional transformer is analyzed, and the conditions in which the application of the EPT can cause less power losses...... reduced power losses in the distribution network require a comprehensive consideration when comparing the power losses of theEPT and conventional transformer. In this paper, a comprehensive power losses analysis model for the EPT in distribution networks is proposed. By analyzing the EPT self-losses......The electronic power transformer (EPT) has highe rpower losses than the conventional transformer. However, the EPT can correct the power factor, compensate the unbalanced current and reduce the line power losses in the distribution network.Therefore, the higher losses of the EPT and the consequent...

  7. Comprehensive Power Losses Model for Electronic Power Transformer

    DEFF Research Database (Denmark)

    Yue, Quanyou; Li, Canbing; Cao, Yijia

    2018-01-01

    The electronic power transformer (EPT) has highe rpower losses than the conventional transformer. However, the EPT can correct the power factor, compensate the unbalanced current and reduce the line power losses in the distribution network.Therefore, the higher losses of the EPT and the consequent...... reduced power losses in the distribution network require a comprehensive consideration when comparing the power losses of theEPT and conventional transformer. In this paper, a comprehensive power losses analysis model for the EPT in distribution networks is proposed. By analyzing the EPT self......-losses and considering the impact of the non-unity power factor and the three-phase unbalanced current, the overall power losses in the distribution network when using the EPT to replace the conventional transformer is analyzed, and the conditions in which the application of the EPT can cause less power losses...

  8. Assessing the potential role of concentrated solar power (CSP) for the northeast power system of Brazil using a detailed power system model

    International Nuclear Information System (INIS)

    Fichter, Tobias; Soria, Rafael; Szklo, Alexandre; Schaeffer, Roberto; Lucena, Andre F.P.

    2017-01-01

    One of the technologies that stand out as an alternative to provide additional flexibility to power systems with large penetration of variable renewable energy (VRE), especially for regions with high direct normal irradiation (DNI), is concentrated solar power (CSP) plants coupled to thermal energy storage (TES) and back-up (BUS) systems. Brazil can develop this technology domestically, especially in its Northeast region, where most of VRE capacity is being deployed and where lies most of the CSP potential of the country. This work applies the Capacity Expansion Model REMix-CEM, which allows considering dispatch constraints of thermal power plants in long-term capacity expansion optimization. REMix-CEM calculates the optimal CSP plant configuration and its dispatch strategy from a central planning perspective. Results showed that the hybridization of CSP plants with jurema-preta biomass (CSP-BIO) becomes a least-cost option for Brazil by 2040. CSP-BIO contributes to the Northeast power system by regularizing the energy imbalance that results from the large-scale VRE expansion along with conventional inflexible power plants. CSP-BIO plants are able to increase frequency response and operational reserve services and can provide the required additional flexibility that the Northeast power system of Brazil will require into the future. - Highlights: • Concentrating solar power (CSP) plants provide flexibility to power systems. • CSP configuration is optimized endogenously during capacity expansion optimization. • CSP hybridized with biomass supports grid-integration of variable renewable energy. • CSP become the least-cost option for the Northeast power system of Brazil by 2040.

  9. Low carbon technologies as providers of operational flexibility in future power systems

    International Nuclear Information System (INIS)

    Pavić, Ivan; Capuder, Tomislav; Kuzle, Igor

    2016-01-01

    Highlights: • Mixed integer linear programming model for provision of multiple services from EV. • EV energy and reserve services provision effects on power system operation. • Impacts of conventional unit’s decommission on system’s operation and flexibility. • Assessment of power system’s flexibility under different wind generation polices. - Abstract: The paper presents a unit commitment model, based on mixed integer linear programming, capable of assessing the impact of electric vehicles (EV) on provision of ancillary services in power systems with high share of renewable energy sources (RES). The analyses show how role of different conventional units changes with integration of variable and uncertain RES and how introducing a flexible sources on the demand side, in this case EV, impact the traditional provision of spinning/contingency reserve services. In addition, technical constraints of conventional units, such as nuclear, gas or coal, limit the inherit flexibility of the system which results in curtailing clean renewable sources and inefficient operation. Following on that, sensitivity analyses of operational cost and wind curtailment shows which techno-economic constraints impact the flexibility of the high RES systems the most and how integration of more flexible units or decommission of conventional nuclear, coal and gas driven power plants would impact the system’s operation. Finally, two different wind generation polices (wind penalization and wind turbines as reserve providers) have been analysed in terms of operational flexibility through different stages of conventional unit’s decommission and compared with the same analyses when EV were used as reserve providers.

  10. Electric Vehicle Based Battery Storages for Future Power System Regulation Services

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2009-01-01

    supplying the reserve power requirements. This limited regulation services from conventional generators in the future power system calls for other new reserve power solutions like Electric Vehicle (EV) based battery storages. A generic aggregated EV based battery storage for long-term dynamic load frequency...

  11. 29 CFR Appendix III to Part 1918 - The Mechanics of Conventional Cargo Gear (Non-mandatory)

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false The Mechanics of Conventional Cargo Gear (Non-mandatory.... 1918, App. III Appendix III to Part 1918—The Mechanics of Conventional Cargo Gear (Non-mandatory) Note: This appendix is non-mandatory and provides an explanation of the mechanics in the correct spotting of...

  12. Marine Gas Hydrates - An Untapped Non-conventional Energy ...

    Indian Academy of Sciences (India)

    Table of contents. Marine Gas Hydrates - An Untapped Non-conventional Energy Resource · Slide 2 · Slide 3 · Slide 4 · Gas Hydrate Stability Zone · Slide 6 · Slide 7 · Exploration of gas hydrates (seismic) · Characteristics of BSR · Slide 10 · Slide 11 · Slide 12 · Slide 13 · Slide 14 · Slide 15 · Distribution of Gas Hydrates in KG ...

  13. Effects Of Using Non-Conventional Feedstuffs On The Productivity ...

    African Journals Online (AJOL)

    This study examines effects of privately producing layers mash by including such non-conventional feedstuff as cassava, brewers dried grain, etc on the productivity, cost and profit of poultry (eggs) farms. Primary data was collected from three categories of farms – 12” convcentional feedstuff users“ (CFU), ...

  14. New insights into non-conventional epitopes as T cell targets: The missing link for breaking immune tolerance in autoimmune disease?

    Science.gov (United States)

    Harbige, James; Eichmann, Martin; Peakman, Mark

    2017-11-01

    The mechanism by which immune tolerance is breached in autoimmune disease is poorly understood. One possibility is that post-translational modification of self-antigens leads to peripheral recognition of neo-epitopes against which central and peripheral tolerance is inadequate. Accumulating evidence points to multiple mechanisms through which non-germline encoded sequences can give rise to these non-conventional epitopes which in turn engage the immune system as T cell targets. In particular, where these modifications alter the rules of epitope engagement with MHC molecules, such non-conventional epitopes offer a persuasive explanation for associations between specific HLA alleles and autoimmune diseases. In this review article, we discuss current understanding of mechanisms through which non-conventional epitopes may be generated, focusing on several recently described pathways that can transpose germline-encoded sequences. We contextualise these discoveries around type 1 diabetes, the prototypic organ-specific autoimmune disease in which specific HLA-DQ molecules confer high risk. Non-conventional epitopes have the potential to act as tolerance breakers or disease drivers in type 1 diabetes, prompting a timely re-evaluation of models of a etiopathogenesis. Future studies are required to elucidate the disease-relevance of a range of potential non-germline epitopes and their relationship to the natural peptide repertoire. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Study of solar array switching power management technology for space power system

    Science.gov (United States)

    Cassinelli, J. E.

    1982-01-01

    This report documents work performed on the Solar Array Switching Power Management Study. Mission characteristics for three missions were defined to the depth necessary to determine their power management requirements. Solar array switching concepts which could satisfy the mission requirements were identified. The switching concepts were compared with a conventional buck regulator system for cost, weight and volume, reliability, efficiency and thermal control. Solar array switching provided significant advantages in all areas of comparison for the reviewed missions.

  16. Vehicle-to-Grid for islanded power system operation in Bornholm

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2010-01-01

    Vehicle-to-Grid (V2G) systems are an emerging concept of utilizing the battery storage of electric vehicles (EVs) for providing power system regulation services. This technology could be used to balance the variable electricity generated from various renewable energy sources. This article considers...... a model of an aggregated electric vehicle based battery storage to support an isolated power system operating with a large wind power penetration in the Danish island of Bornholm. From the simulation results, the EV battery storages represented by the V2G systems are able to integrate more fluctuating...... wind power. The islanded Bornholm power system operates satisfactory for the case of replacing most of the conventional generator reserves with V2G systems, which may represent a future operation scenario....

  17. Maximum Power Point Tracking of Photovoltaic System for Traffic Light Application

    OpenAIRE

    Muhida, Riza; Mohamad, Nor Hilmi; Legowo, Ari; Irawan, Rudi; Astuti, Winda

    2013-01-01

    Photovoltaic traffic light system is a significant application of renewable energy source. The development of the system is an alternative effort of local authority to reduce expenditure for paying fees to power supplier which the power comes from conventional energy source. Since photovoltaic (PV) modules still have relatively low conversion efficiency, an alternative control of maximum power point tracking (MPPT) method is applied to the traffic light system. MPPT is intended to catch up th...

  18. Hydrogen fuel cell power system

    International Nuclear Information System (INIS)

    Lam, A.W.

    2004-01-01

    'Full text:' Batteries are typically a necessary and prime component of any DC power system, providing a source of on-demand stored energy with proven reliability. The integration of batteries and basic fuel cells for mobile and stationary utility applications poses a new challenge. For high value applications, the specification and operating requirements for this hybrid module differ from conventional requirements as the module must withstand extreme weather conditions and provide extreme reliability. As an electric utility company, BCHydro has embarked in the development and application of a Hydrogen Fuel Cell Power Supply (HFCPS) for field trial. A Proton Exchange Membrane (PEM)- type fuel cell including power electronic modules are mounted in a standard 19-inch rack that provides 48V, 24V, 12V DC and 120V AC outputs. The hydrogen supply consists of hydrogen bottles and regulating devices to provide a continuous fuel source to the power modules. Many tests and evaluations have been done to ensure the HFCPS package is robust and suitable for electric utility grade operation. A field trial demonstrating this standalone system addressed reliability, durability, and installation concerns as well as developed the overall system operating procedures. (author)

  19. Augmented Nonlinear Controller for Maximum Power-Point Tracking with Artificial Neural Network in Grid-Connected Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Suliang Ma

    2016-11-01

    Full Text Available Photovoltaic (PV systems have non-linear characteristics that generate maximum power at one particular operating point. Environmental factors such as irradiance and temperature variations greatly affect the maximum power point (MPP. Diverse offline and online techniques have been introduced for tracking the MPP. Here, to track the MPP, an augmented-state feedback linearized (AFL non-linear controller combined with an artificial neural network (ANN is proposed. This approach linearizes the non-linear characteristics in PV systems and DC/DC converters, for tracking and optimizing the PV system operation. It also reduces the dependency of the designed controller on linearized models, to provide global stability. A complete model of the PV system is simulated. The existing maximum power-point tracking (MPPT and DC/DC boost-converter controller techniques are compared with the proposed ANN method. Two case studies, which simulate realistic circumstances, are presented to demonstrate the effectiveness and superiority of the proposed method. The AFL with ANN controller can provide good dynamic operation, faster convergence speed, and fewer operating-point oscillations around the MPP. It also tracks the global maxima under different conditions, especially irradiance-mutating situations, more effectively than the conventional methods. Detailed mathematical models and a control approach for a three-phase grid-connected intelligent hybrid system are proposed using MATLAB/Simulink.

  20. New scenario of the non-conventional renewable energies on Chile after the incentives created on the ''Short Law I''

    International Nuclear Information System (INIS)

    Leonardo, Valencia M.

    2008-01-01

    Non-conventional renewable energies have never played an important role in the Chilean energy generation system, mainly due to the economic barriers that actually exists on our country for the inclusion of these kinds of technologies. Nevertheless, the use of renewable energy system technologies have started to be an interesting issue for the Chilean government, and for that reason, the last modification of the Energy Law during 2004, usually known as ''Short Law I'', introduced the first direct incentive to renewable energy generation (specifically in the art. 71-7). In this work we analyze in detail the modification on the electric law we mentioned before, especially for geothermal and wind power generation, and we compare the economic incentive generated with the new law and the differences between the real energy costs using renewable energy systems technologies and the current energy price in Chile. It is clear from the analysis that the total incentives do not cover more than 8.3% of the price differences between incomes and costs. (author)

  1. Optimum power quality service in multi-bus microgrid systems

    DEFF Research Database (Denmark)

    Meng, Lexuan; Guerrero, Josep M.

    2017-01-01

    Power quality requirements for different consumers and electric equipment are distinguished. Conventionally a common power quality standard is applied to the whole power grid inducing debate between several sides, including consumers, generation sites and technical commissions. Customized power...... quality standard settings for different consumers become a widely accepted solution. The main challenge is on the proper regulation of power quality in different areas. This paper considers a multi-bus microgrid system where the power quality in each has flexible and individual standard. Distributed...... generators are utilized to provide power quality regulation functions. An optimization method based strategy is proposed and implemented with the power converter control system. A general mathematical model is established which can be used in the optimization problem for evaluating the objective function...

  2. Demand side resource operation on the Irish power system with high wind power penetration

    DEFF Research Database (Denmark)

    Keane, A.; Tuohy, A.; Meibom, Peter

    2011-01-01

    part of the power system plant mix and contribute to the flexible operation of a power system. A model for demand side resources is proposed here that captures its key characteristics for commitment and dispatch calculations. The model is tested on the all island Irish power system, and the operation...... of the functions of conventional peaking plant. Demand side resources are also shown to be capable of improving the reliability of the system, with reserve capability identified as a key requirement in this respect....... of the model is simulated over one year in both a stochastic and deterministic mode, to illustrate the impact of wind and load uncertainty. The results illustrate that demand side resources can contribute to the efficient, flexible operation of systems with high penetrations of wind by replacing some...

  3. Increasing Water System Efficiency with Ultrafiltration Pre-treatment in Power Plants

    International Nuclear Information System (INIS)

    Majamaa, Katariina; Suarez, Javier; Gasia Eduard

    2012-09-01

    Water demineralization with reverse osmosis (RO) membranes has a long and successful history in water treatment for power plants. As the industry strives for more efficient, reliable and compact water systems, pressurized hollow-fiber ultrafiltration (UF) has become an increasingly appealing pre-treatment technology. Compared to conventional, non- membrane based pretreatments, ultrafiltration offers higher efficiency in the removal of suspended solids, microorganisms and colloidal matter, which are all common causes for operational challenges experienced in the RO systems. In addition, UF is more capable of handling varying feed water qualities and removes the risk of particle carry-over often seen with conventional filtration techniques. Ultrafiltration is a suitable treatment technology for various water types from surface waters to wastewater, and the more fluctuating or challenging the feed water source is, the better the benefits of UF are seen compared to conventional pretreatments. Regardless of the feed water type, ultrafiltration sustains a constant supply of high quality feed water to downstream RO, allowing a more compact and cost efficient RO system design with improved operational reliability. A detailed focus on the design and operational aspects and experiences of two plants is provided. These examples demonstrate both economical UF operation and tangible impact of RO process improvement. Experience from these plants can be leveraged to new projects. (authors)

  4. Wind power: Italian auto-production legislation (ISES convention)

    International Nuclear Information System (INIS)

    Mari, G.

    1991-01-01

    With reference to what was discussed at the Bologna (Italy) June 1991 ISES (International Solar Energy Society) convention on wind energy, this paper summarizes the Italian legislative framework relative to on-site power generation and outlines the National Energy Plan objectives regarding the promotion of the use, by industry, of renewable energy sources. Brief notes are also provided on wind energy promotional activities being carried out by ENEL (the Italian National Energy Board), ENEA (Italian Agency for New Technologies, Energy and the Environment), and EWEA (the European Wind Energy Association)

  5. Unrest in Utopia: Israeli patients' dissatisfaction with non-conventional medicine.

    Science.gov (United States)

    Fadlon, Judith

    2004-06-01

    In recent years, non-conventional medicine (NCM) has grown tremendously in popularity and economic importance. This paper explores a relatively unresearched phenomenon: patients' dissatisfaction with non-conventional medical treatment they have received. 16 out of 20 patients who had severed their contact with a large, hospital-adjacent multi-modality NCM clinic in Israel were interviewed. Two of these patients had severed their relationship with the clinic right after being referred to a certain practitioner and 18 did not keep their next appointment while in the process of treatment. The narratives through which participants understand and communicate their experience regarding dissatisfaction with NCM are organized around three main topics: independence versus paternalism, foreign versus familiar, and care versus cure. Findings illustrate the patients' views concerning the desirable doctor-patient relationship and their expectations of non-familiar treatments. Patients are characterized as "smart consumers" who place utmost importance on outcome and do not hesitate to discontinue treatment. Findings are further discussed in the context of domestication and the minimizing of cultural difference through the integration of NCM into a biomedical setting.

  6. Non-Conventional Methodologies in the Synthesis of 1-Indanones

    Directory of Open Access Journals (Sweden)

    Manuela Oliverio

    2014-04-01

    Full Text Available 1-Indanones have been successfully prepared by means of three different non-conventional techniques, namely microwaves, high-intensity ultrasound and a Q-tube™ reactor. A library of differently substituted 1-indanones has been prepared via one-pot intramolecular Friedel-Crafts acylation and their efficiency and “greenness” have been compared.

  7. Non-contacting actuation by radiation powered telemetry system

    International Nuclear Information System (INIS)

    Wang Xiaolin; Zhao Chunnong; Kapitola, Peter; Jacob, John; Ju Li; Blair, David G

    2004-01-01

    In laser interferometer gravitational wave detectors, local control relative to vibration isolated parts of a suspension chain may introduce noise through wires. In this paper we present a feasibility study of a wireless signal transmission method for control systems. A prototype system provides a wireless two-way signal transmission over short distances at more than 800 kbits s -1 . Wireless electric power for the system may be provided using a diode laser and solar cells with up to 33% conversion efficiency

  8. Optimal pricing of non-utility generated electric power

    International Nuclear Information System (INIS)

    Siddiqi, S.N.; Baughman, M.L.

    1994-01-01

    The importance of an optimal pricing policy for pricing non-utility generated power is pointed out in this paper. An optimal pricing policy leads to benefits for all concerned: the utility, industry, and the utility's other customers. In this paper, it is shown that reliability differentiated real-time pricing provides an optimal non-utility generated power pricing policy, from a societal welfare point of view. Firm capacity purchase, and hence an optimal price for purchasing firm capacity, are an integral part of this pricing policy. A case study shows that real-time pricing without firm capacity purchase results in improper investment decisions and higher costs for the system as a whole. Without explicit firm capacity purchase, the utility makes greater investment in capacity addition in order to meet its reliability criteria than is socially optimal. It is concluded that the non-utility generated power pricing policy presented in this paper and implied by reliability differentiated pricing policy results in social welfare-maximizing investment and operation decisions

  9. The role of co-located storage for wind power producers in conventional electricity markets

    KAUST Repository

    Bitar, E.; Rajagopal, R.; Khargonekar, P.; Poolla, K.

    2011-01-01

    In this paper we study the problem of optimizing contract offerings for an independent wind power producer (WPP) participating in conventional day-ahead forward electricity markets for energy. As wind power is an inherently variable source of energy

  10. Naval Open Architecture Machinery Control Systems for Next Generation Integrated Power Systems

    Science.gov (United States)

    2012-05-01

    MTGs/ATGs Energy Storage Modules (ESMs) Regenerative Drives Ship Service Loads Propulsion Drives Mission Systems Emergency DGs Shore Power Weapon...delivering power, and acting as a power source when discharging, spinning down, or regeneratively braking . Uninterruptable Power Supply (UPS...RESERVES REGENERATIVE VARIABLE SPEED DRIVES NON- REGENERATIVE VARIABLE SPEED DRIVES HYBRID ELECTRIC DRIVES SYSTEMS W/SPECIAL POWER CHARACTERISTICS

  11. Demand side resource operation on the Irish power system with high wind power penetration

    International Nuclear Information System (INIS)

    Keane, A.; Tuohy, A.; Meibom, P.; Denny, E.; Flynn, D.; Mullane, A.; O'Malley, M.

    2011-01-01

    The utilisation of demand side resources is set to increase over the coming years with the advent of advanced metering infrastructure, home area networks and the promotion of increased energy efficiency. Demand side resources are proposed as an energy resource that, through aggregation, can form part of the power system plant mix and contribute to the flexible operation of a power system. A model for demand side resources is proposed here that captures its key characteristics for commitment and dispatch calculations. The model is tested on the all island Irish power system, and the operation of the model is simulated over one year in both a stochastic and deterministic mode, to illustrate the impact of wind and load uncertainty. The results illustrate that demand side resources can contribute to the efficient, flexible operation of systems with high penetrations of wind by replacing some of the functions of conventional peaking plant. Demand side resources are also shown to be capable of improving the reliability of the system, with reserve capability identified as a key requirement in this respect. - Highlights: → Demand side resource model presented for use in unit commitment and dispatch calculations. → Benefits of demand side aggregation demonstrated specifically as a peaking unit and provider of reserve. → Potential to displace or defer construction of conventional peaking units.

  12. Gaseous fuel reactors for power systems

    Science.gov (United States)

    Kendall, J. S.; Rodgers, R. J.

    1977-01-01

    Gaseous-fuel nuclear reactors have significant advantages as energy sources for closed-cycle power systems. The advantages arise from the removal of temperature limits associated with conventional reactor fuel elements, the wide variety of methods of extracting energy from fissioning gases, and inherent low fissile and fission product in-core inventory due to continuous fuel reprocessing. Example power cycles and their general performance characteristics are discussed. Efficiencies of gaseous fuel reactor systems are shown to be high with resulting minimal environmental effects. A technical overview of the NASA-funded research program in gaseous fuel reactors is described and results of recent tests of uranium hexafluoride (UF6)-fueled critical assemblies are presented.

  13. Non-intrusive Methods for Mode Estimation in Power Systems using Synchrophasors

    NARCIS (Netherlands)

    Peri?, V.

    2016-01-01

    The power system industry has been going through dynamic infrastructural and operational changes in recent years that have caused more prominent lightly damped electromechanical oscillations. Real-time monitoring of electromechanical oscillations is of great significance for power system operators;

  14. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  15. Wind power systems. Applications of computational intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lingfeng [Toledo Univ., OH (United States). Dept. of Electrical Engineering and Computer Science; Singh, Chanan [Texas A and M Univ., College Station, TX (United States). Electrical and Computer Engineering Dept.; Kusiak, Andrew (eds.) [Iowa Univ., Iowa City, IA (United States). Mechanical and Industrial Engineering Dept.

    2010-07-01

    Renewable energy sources such as wind power have attracted much attention because they are environmentally friendly, do not produce carbon dioxide and other emissions, and can enhance a nation's energy security. For example, recently more significant amounts of wind power are being integrated into conventional power grids. Therefore, it is necessary to address various important and challenging issues related to wind power systems, which are significantly different from the traditional generation systems. This book is a resource for engineers, practitioners, and decision-makers interested in studying or using the power of computational intelligence based algorithms in handling various important problems in wind power systems at the levels of power generation, transmission, and distribution. Researchers have been developing biologically-inspired algorithms in a wide variety of complex large-scale engineering domains. Distinguished from the traditional analytical methods, the new methods usually accomplish the task through their computationally efficient mechanisms. Computational intelligence methods such as evolutionary computation, neural networks, and fuzzy systems have attracted much attention in electric power systems. Meanwhile, modern electric power systems are becoming more and more complex in order to meet the growing electricity market. In particular, the grid complexity is continuously enhanced by the integration of intermittent wind power as well as the current restructuring efforts in electricity industry. Quite often, the traditional analytical methods become less efficient or even unable to handle this increased complexity. As a result, it is natural to apply computational intelligence as a powerful tool to deal with various important and pressing problems in the current wind power systems. This book presents the state-of-the-art development in the field of computational intelligence applied to wind power systems by reviewing the most up

  16. Short-Term Planning of Hybrid Power System

    Science.gov (United States)

    Knežević, Goran; Baus, Zoran; Nikolovski, Srete

    2016-07-01

    In this paper short-term planning algorithm for hybrid power system consist of different types of cascade hydropower plants (run-of-the river, pumped storage, conventional), thermal power plants (coal-fired power plants, combined cycle gas-fired power plants) and wind farms is presented. The optimization process provides a joint bid of the hybrid system, and thus making the operation schedule of hydro and thermal power plants, the operation condition of pumped-storage hydropower plants with the aim of maximizing profits on day ahead market, according to expected hourly electricity prices, the expected local water inflow in certain hydropower plants, and the expected production of electrical energy from the wind farm, taking into account previously contracted bilateral agreement for electricity generation. Optimization process is formulated as hourly-discretized mixed integer linear optimization problem. Optimization model is applied on the case study in order to show general features of the developed model.

  17. Control system security in nuclear power plant

    International Nuclear Information System (INIS)

    Li Jianghai; Huang Xiaojin

    2012-01-01

    The digitalization and networking of control systems in nuclear power plants has brought significant improvements in system control, operation and maintenance. However, the highly digitalized control system also introduces additional security vulnerabilities. Moreover, the replacement of conventional proprietary systems with common protocols, software and devices makes these vulnerabilities easy to be exploited. Through the interaction between control systems and the physical world, security issues in control systems impose high risks on health, safety and environment. These security issues may even cause damages of critical infrastructures and threaten national security. The importance of control system security by reviewing several control system security incidents that happened in nuclear power plants was showed in recent years. Several key difficulties in addressing these security issues were described. Finally, existing researches on control system security and propose several promising research directions were reviewed. (authors)

  18. Optimal LFC SMC for three – area power system with high penetration of PV

    Directory of Open Access Journals (Sweden)

    Maksymilian Klimontowicz

    2016-03-01

    Full Text Available Electrical power systems are subjected to new trends appearing in grid structuring, electrical power sources, new control strategies, etc. The introduction of inverterbased distributed energy resources to replace conventional synchronous machines depletes the mechanical inertia, and causing the system to become more sensitive to disturbances. This paper proposed a simple and reliable solution to assure sufficient frequency stability of electrical power systems when subjected to high penetration of decoupled distributed generation. To achieve this, a decentralized sliding mode control was designed to operate as a compensator for conventional load frequency controllers. Subsequently, PV farms and battery energy storage systems were interconnected. Simulated network under different configurations were conducted using MATLAB.

  19. Scheduling Model for Renewable Energy Sources Integration in an Insular Power System

    Directory of Open Access Journals (Sweden)

    Gerardo J. Osório

    2018-01-01

    Full Text Available Insular power systems represent an asset and an excellent starting point for the development and analysis of innovative tools and technologies. The integration of renewable energy resources that has taken place in several islands in the south of Europe, particularly in Portugal, has brought more uncertainty to production management. In this work, an innovative scheduling model is proposed, which considers the integration of wind and solar resources in an insular power system in Portugal, with a strong conventional generation basis. This study aims to show the benefits of increasing the integration of renewable energy resources in this insular power system, and the objectives are related to minimizing the time for which conventional generation is in operation, maximizing profits, reducing production costs, and consequently, reducing greenhouse gas emissions.

  20. Model predictive control for power fluctuation supression in hybrid wind/PV/battery systems

    DEFF Research Database (Denmark)

    You, Shi; Liu, Zongyu; Zong, Yi

    2015-01-01

    A hybrid energy system, the combination of wind turbines, PV panels and battery storage with effective control mechanism, represents a promising solution to the power fluctuation problem when integrating renewable energy resources (RES) into conventional power systems. This paper proposes a model...

  1. Investigations to the potential of the high temperature reactor for steam power processes with highest steam conditions and comparison with according conventional power plants

    International Nuclear Information System (INIS)

    Mondry, M.

    1988-04-01

    Already in the fifties conventional power plants with high parameters of the live steam were built to improve the total efficiency. The power plant with the highest steam conditions in the Federal Republic of Germany has 300 bar pressure and 600deg C temperature. Because of high material costs and other problems power plants with such high conditions were not continued to be built. Standard conditions of today's power plants are in the order of 180-250 bar pressure and 535deg C temperature. As the high temperature reactor is partly built up in another way than a conventional power plant, the results regarding the high steam parameters are not transferable. Possibilities for the technical realization of determined HTR-specific components are introduced and discussed. Then different HTR-power plants with steam conditions up to 350 bar pressure and 650deg C temperature are projected. Economical considerations show that an HTR with higher steam parameters brings financial profits. Further efficiency increase, which is possible by the high steam conditions, is shortly presented. The work ends with a technical and economical comparison of corresponding conventional power plants. (orig./UA) [de

  2. Non-Conventional Thermodynamics and Models of Gradient Elasticity

    Directory of Open Access Journals (Sweden)

    Hans-Dieter Alber

    2018-03-01

    Full Text Available We consider material bodies exhibiting a response function for free energy, which depends on both the strain and its gradient. Toupin–Mindlin’s gradient elasticity is characterized by Cauchy stress tensors, which are given by space-like Euler–Lagrange derivative of the free energy with respect to the strain. The present paper aims at developing a first version of gradient elasticity of non-Toupin–Mindlin’s type, i.e., a theory employing Cauchy stress tensors, which are not necessarily expressed as Euler–Lagrange derivatives. This is accomplished in the framework of non-conventional thermodynamics. A one-dimensional boundary value problem is solved in detail in order to illustrate the differences of the present theory with Toupin–Mindlin’s gradient elasticity theory.

  3. Smart Shipboard Power System Operation and Management

    Directory of Open Access Journals (Sweden)

    Fotis D. Kanellos

    2016-11-01

    Full Text Available During recent years, optimal electrification of isolated offshore systems has become increasingly important and received extensive attention from the maritime industry. Especially with the introduction of electric propulsion, which has led to a total electrification of shipboard power systems known as all-electric ships (AESs, the need for more cost-effective and emission-aware solutions is augmented. Such onboard systems are prone to sudden load variations due to the changing weather conditions as well as mission profile, thus they require effective power management systems (PMSs to operate optimally under different working conditions. In this paper, coordinated optimal power management at the supply/demand side of a given AES is studied with regard to different objectives and related technical/environmental constraints. The optimal power management problem is formulated as a mixed-integer nonlinear programming (MINLP model and is solved using a metaheuristic algorithm. To show the effectiveness and applicability of the proposed PMS, several test scenarios are implemented and related simulation results are analyzed and compared to those from conventional methods.

  4. A congestion line flow control in deregulated power system

    Directory of Open Access Journals (Sweden)

    Venkatarajan Shanmuga Sundaram

    2011-01-01

    Full Text Available Under open access, market-driven transactions have become the new independent decision variables defining the behavior of the power system. The possibility of transmission lines getting over-loaded is relatively more under deregulated operation because different parts of the system are owned by separate companies and in part operated under varying service charges. This paper discusses a two-tier algorithm for correcting the lone overloads in conjunction with the conventional power-flow methods. The method uses line flow sensitivities, which are computed by the East Decoupled Power-flow algorithm and can be adapted for on-line implementation.

  5. An Information-Theoretic Approach to PMU Placement in Electric Power Systems

    OpenAIRE

    Li, Qiao; Cui, Tao; Weng, Yang; Negi, Rohit; Franchetti, Franz; Ilic, Marija D.

    2012-01-01

    This paper presents an information-theoretic approach to address the phasor measurement unit (PMU) placement problem in electric power systems. Different from the conventional 'topological observability' based approaches, this paper advocates a much more refined, information-theoretic criterion, namely the mutual information (MI) between the PMU measurements and the power system states. The proposed MI criterion can not only include the full system observability as a special case, but also ca...

  6. Management of Conventional Wastes (Non Radioactive) in Spanish Landfills

    International Nuclear Information System (INIS)

    Carreras, N.; Pena, J. M.; Ramos, J. L.; Millan, R.

    2011-01-01

    This report is the result of a collaboration agreement between CIEMAT and ENRESA. The goal of the report is to analyze the existing legislation on solid conventional waste, according to the European Community, the Spanish State and its Autonomous Communities, focusing on the latest regulation applicable to the final management in controlled landfills. In addition, information about the legal frame, production, composition and characteristics of conventional waste (i.e. urban, inert, dangerous industrial and non dangerous industrial) is given. Also, the final management that is carried out nowadays in Spain for each of the waste is analyzed and evaluated. Finally, the fulfilment of the in force regulation by the different types of Spanish controlled landfills is evaluated. (Author) 52 refs.

  7. Operation and maintenance support expert systems for BWR nuclear power plants

    International Nuclear Information System (INIS)

    Miyazawa, Tatsuo; Hayakawa, Hiroyasu; Fukutomi, Shigeki

    1990-01-01

    Toshiba has been developing expert systems for operation and maintenance support in BWRs. These expert systems are designed to be integrated with conventional plant monitoring systems, and maintenance management systems to provide both comprehensive and powerful support capabilities. Some of these expert systems are already being used on a trial basis both within Toshiba and in electric power utility companies. This paper describes expert systems for the support of plant and equipment monitoring, maintenance scheduling, and maintenance work procedure planning. (author)

  8. Assessment of a satellite power system and six alternative technologies

    Energy Technology Data Exchange (ETDEWEB)

    Wolsko, T.; Whitfield, R.; Samsa, M.; Habegger, L.S.; Levine, E.; Tanzman, E.

    1981-04-01

    The satellite power system is assessed in comparison to six alternative technologies. The alternatives are: central-station terrestrial photovoltaic systems, conventional coal-fired power plants, coal-gasification/combined-cycle power plants, light water reactor power plants, liquid-metal fast-breeder reactors, and fusion. The comparison is made regarding issues of cost and performance, health and safety, environmental effects, resources, socio-economic factors, and insitutional issues. The criteria for selecting the issues and the alternative technologies are given, and the methodology of the comparison is discussed. Brief descriptions of each of the technologies considered are included. (LEW)

  9. Conceptual study of superconducting urban area power systems

    International Nuclear Information System (INIS)

    Noe, Mathias; Gold-acker, Wilfried; Bach, Robert; Prusseit, Werner; Willen, Dag; Poelchau, Juri; Linke, Christian

    2010-01-01

    Efficient transmission, distribution and usage of electricity are fundamental requirements for providing citizens, societies and economies with essential energy resources. It will be a major future challenge to integrate more sustainable generation resources, to meet growing electricity demand and to renew electricity networks. Research and development on superconducting equipment and components have an important role to play in addressing these challenges. Up to now, most studies on superconducting applications in power systems have been concentrated on the application of specific devices like for example cables and current limiters. In contrast to this, the main focus of our study is to show the consequence of a large scale integration of superconducting power equipment in distribution level urban power systems. Specific objectives are to summarize the state-of-the-art of superconducting power equipment including cooling systems and to compare the superconducting power system with respect to energy and economic efficiency with conventional solutions. Several scenarios were considered starting from the replacement of an existing distribution level sub-grid up to a full superconducting urban area distribution level power system. One major result is that a full superconducting urban area distribution level power system could be cost competitive with existing solutions in the future. In addition to that, superconducting power systems offer higher energy efficiency as well as a number of technical advantages like lower voltage drops and improved stability.

  10. Calculation of economic and financing of NPP and conventional power plant using spreadsheet innovation

    International Nuclear Information System (INIS)

    Moch Djoko Birmano; Imam Bastori

    2008-01-01

    The study for calculating the economic and financing of Nuclear Power Plant (NPP) and conventional power plant using spreadsheet Innovation has been done. As case study, the NPP of PWR type of class 1050 MWe is represented by OPR-1000 (Optimized Power Reactor, 1000 MWe) and the conventional plant of class 600 MWe, is coal power plant (Coal PP). The purpose of the study is to assess the economic and financial feasibility level of OPR-1000 and Coal PP. The study result concludes that economically, OPR-1000 is more feasible compared to Coal PP because its generation cost is cheaper. Whereas financially, OPR-1000 is more beneficial compared to Coal PP because the higher benefit at the end of economic lifetime (NPV) and the higher ratio of benefit and cost (B/C Ratio). For NPP and Coal PP, the higher Discount Rate (%) is not beneficial. NPP is more sensitive to the change of discount rate compared to coal PP, whereas Coal PP is more sensitive to the change of power purchasing price than NPP. (author)

  11. Sustainable and non-conventional monitoring systems to mitigate natural hazards in low income economies: the 4onse project approach.

    Science.gov (United States)

    Cannata, Massimiliano; Ratnayake, Rangajeewa; Antonovic, Milan; Strigaro, Daniele

    2017-04-01

    Environmental monitoring systems in low economies countries are often in decline, outdated or missing with the consequence that there is a very scarce availability and accessibility to these information that are vital for coping and mitigating natural hazards. Non-conventional monitoring systems based on open technologies may constitute a viable solution to create low cost and sustainable monitoring systems that may be fully developed, deployed and maintained at local level without lock-in dependances on copyrights or patents or high costs of replacements. The 4onse research project , funded under the Research for Development program of the Swiss National Science Foundation and the Swiss Office for Development and Cooperation, propose a complete monitoring system that integrates Free & Open Source Software, Open Hardware, Open Data, and Open Standards. After its engineering, it will be tested in the Deduru Oya catchment (Sri Lanka) to evaluate the system and develop a water management information system to optimize the regulation of artificial basins levels and mitigate flash floods. One of the objective is to better scientifically understand strengths, criticalities and applicabilities in terms of data quality; system durability; management costs; performances; sustainability. Results, challenges and experiences from the first six months of the projects will be presented with particular focus on the activities of synergies building and data collection and dissemination system advances.

  12. Protein folding and non-conventional drug design: a primer for nuclear structure physicists

    International Nuclear Information System (INIS)

    Broglia, R.A.; Tiana, G.; Provasi, D.

    2004-01-01

    Some of the paradigms emerging from the study of the phenomena of phase transitions in finite many-body systems, like e.g. the atomic nucleus can be used at profit to solve the protein folding problem within the framework of simple (although not oversimplified) models. From this solution a paradigm emerges for the design of non-conventional drugs, which inhibit enzymatic action without inducing resistance (mutations). The application of these concepts to the design of an inhibitor to the HIV-protease central in the life cycle of the HIV virus is discussed

  13. Study on the optimization allocation of wind-solar in power system based on multi-region production simulation

    Directory of Open Access Journals (Sweden)

    Xu Zhicheng

    2018-01-01

    Full Text Available In this paper, a power supply optimization model is proposed. The model takes the minimum fossil energy consumption as the target, considering the output characteristics of the conventional power supply and the renewable power supply. The optimal capacity ratio of wind-solar in the power supply under various constraints is calculated, and the interrelation between conventional power supply and renewable energy is analyzed in the system of high proportion renewable energy integration. Using the model, we can provide scientific guidance for the coordinated and orderly development of renewable energy and conventional power sources.

  14. Opportunities for utilization of non-conventional energy sources for biomass pretreatment.

    Science.gov (United States)

    Singh, Rawel; Krishna, Bhavya B; Kumar, Jitendra; Bhaskar, Thallada

    2016-01-01

    The increasing concerns over the depletion of fossil resources and its associated geo-political issues have driven the entire world to move toward sustainable forms of energy. Pretreatment is the first step in any biochemical conversion process for the production of valuable fuels/chemicals from lignocellulosic biomass to eliminate the lignin and produce fermentable sugars by hydrolysis. Conventional techniques have several limitations which can be addressed by using them in tandem with non-conventional methods for biomass pretreatment. Electron beam and γ (gamma)-irradiation, microwave and ultrasound energies have certain advantages over conventional source of energy and there is an opportunity that these energies can be exploited for biomass pretreatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Prerequisites for a nuclear weapons convention

    International Nuclear Information System (INIS)

    Liebert, W.

    1999-01-01

    A Nuclear Weapons Convention (NWC) would prohibit the research, development, production, testing, stockpiling, transfer, use and threat of use of nuclear weapons and would serve their total elimination.' In this fashion it follows the model laid out by the biological and chemical weapons conventions. The NWC would encompass a few other treaties and while replacing them should learn from their experiences. The Nuclear Weapons Convention should at some given point in the future replace the Non-Proliferation Treaty (NPT) and so resolve its contradictions and shortcomings. The main objectives of an NWC Would be: reduction of the nuclear arsenals of the 'five' nuclear weapons powers down to zero within a set of fixed periods of time; elimination of stockpiles of weapons-usable materials and, where existent, nuclear warheads in de-facto nuclear weapon and threshold states; providing assurance that all states will retain their non-nuclear status forever

  16. Decentralized linear quadratic power system stabilizers for multi ...

    Indian Academy of Sciences (India)

    Linear quadratic stabilizers are well-known for their superior control capabilities when compared to the conventional lead–lag power system stabilizers. However, they have not seen much of practical importance as the state variables are generally not measurable; especially the generator rotor angle measurement is not ...

  17. Managing Sustainable Demand-side Infrastructure for Power System Ancillary Services

    Science.gov (United States)

    Parkinson, Simon Christopher

    Widespread access to renewable electricity is seen as a viable method to mitigate carbon emissions, although problematic are the issues associated with the integration of the generation systems within current power system configurations. Wind power plants are the primary large-scale renewable generation technology applied globally, but display considerable short-term supply variability that is difficult to predict. Power systems are currently not designed to operate under these conditions, and results in the need to increase operating reserve in order to guarantee stability. Often, operating conventional generation as reserve is both technically and economically inefficient, which can overshadow positive benefits associated with renewable energy exploitation. The purpose of this thesis is to introduce and assess an alternative method of enhancing power system operations through the control of electric loads. In particular, this thesis focuses on managing highly-distributed sustainable demand-side infrastructure, in the form of heat pumps, electric vehicles, and electrolyzers, as dispatchable short-term energy balancing resources. The main contribution of the thesis is an optimal control strategy capable of simultaneously balancing grid- and demand-side objectives. The viability of the load control strategy is assessed through model-based simulations that explicitly track end-use functionality of responsive devices within a power systems analysis typically implemented to observe the effects of integrated wind energy systems. Results indicate that there is great potential for the proposed method to displace the need for increased reserve capacity in systems considering a high penetration of wind energy, thereby allowing conventional generation to operate more efficiently and avoid the need for possible capacity expansions.

  18. A Clash of Conventions? Participation, Power and the Rights of Disabled Children

    Directory of Open Access Journals (Sweden)

    Ralph Sandland

    2017-09-01

    Full Text Available This article considers the neglected topic of the relationship between the Convention on the Rights of Persons with Disabilities and the Convention on the Rights of the Child, with regard to the participation rights of disabled children. It analyses key articles in both conventions and considers relevant general comments from both convention committees (the Committee on the Rights of the Child and the Committee on the Rights of Persons with Disabilities, and their interpretation by academic contributors. The article argues that much work on this topic fails to develop an adequate understanding of power relations, and that the ‘social model of disability’ which underpins the disabilities convention, when applied to ‘childhood’ (as opposed to ‘children’ suggests that the implications of that convention for the participation rights of all children, not only disabled children, are profound. This is because the disabilities convention rejects the relevance of tests of capacity and ‘best interests’ for disabled adults, for reasons which are equally germane to disabled children, and children in general. The article concludes with discussion of the difficulties in implementing the insights derived from the analysis of the disabilities convention in substantive law in the absence of a right to freedom from age discrimination for children, and suggests other, less far-reaching, reforms that could be made this notwithstanding.

  19. Hybrid Systems of Distributed Generation with Renewable Sources: Modeling and Analysis of Their Operational Modes in Electric Power System

    Directory of Open Access Journals (Sweden)

    A. M. Gashimov

    2013-01-01

    Full Text Available The paper considers problems pertaining to modeling and simulation of operational hybrid system modes of the distributed generation comprising conventional sources – modular diesel generators, gas-turbine power units; and renewable sources – wind and solar power plants. Operational modes of the hybrid system have been investigated under conditions of electrical connection with electric power system and in case of its isolated operation. As a consequence

  20. Voltage control in the future power transmission systems

    DEFF Research Database (Denmark)

    Qin, Nan

    Wind energy in Denmark covers 42% of the total power consumption in 2015, and will share up to 50% by 2020. Consequently, the conventional power plants are decommissioning. Under the progress of the green transition, the national decision leads to underground many overhead lines in the future...... stages. The voltage uncertainty caused by the wind power forecasting errors is estimated, which is applied as a voltage security margin to further constrain the voltage magnitude in the optimization problem. The problem under the uncertainty is therefore converted to a deterministic problem, which...... to ensure a highly reliable transmission, e.g. balancing the generation and the consumption in large geographic regions, the exchange capacities will be enlarged by upgrading the interconnections. The Danish power system, the electricity transportation hub between the Nordic and continental European systems...

  1. Simulation of solar-powered absorption cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Atmaca, I.; Yigit, A. [Uludag Univ., Bursa (Turkey). Dept. of Mechanical Engineering

    2003-07-01

    With developing technology and the rapid increase in world population, the demand for energy is ever increasing. Conventional energy will not be enough to meet the continuously increasing need for energy in the future. In this case, renewable energy sources will become important. Solar energy is a very important energy source because of its advantages. Instead of a compressor system, which uses electricity, an absorption cooling system, using renewable energy and kinds of waste heat energy, may be used for cooling. In this study, a solar-powered, single stage, absorption cooling system, using a water-lithium bromide solution, is simulated. A modular computer program has been developed for the absorption system to simulate various cycle configurations and solar energy parameters for Antalya, Turkey. So, the effects of hot water inlet temperatures on the coefficient of performance (COP) and the surface area of the absorption cooling components are studied. In addition, reference temperatures which are the minimum allowable hot water inlet temperatures are determined and their effect on the fraction of the total load met by non-purchased energy (FNP) and the coefficient of performance are researched. Also, the effects of the collector type and storage tank mass are investigated in detail. (author)

  2. Harmonics and voltage stability analysis in power systems including

    Indian Academy of Sciences (India)

    In this study, non-sinusoidal quantities and voltage stability, both known as power quality criteria, are examined together in detail. The widespread use of power electronics elements cause the existence of significant non-sinusoidal quantities in the system. These non-sinusoidal quantities can create serious harmonic ...

  3. Islamic vs. Conventional Banking Role in Non-Oil Growth: A Causal Analysis in the Case of Bahrain

    Directory of Open Access Journals (Sweden)

    Abdallah Belhadia

    2014-12-01

    Full Text Available This paper aims to investigate the type of relationship between Islamic vs. Conventional banking and non-Oil economic growth in the case of Bahrain by using annual data 1990-2012 retrieved from Islamic banks and financial institutions information (Ibis-Online of the Islamic Bank of Development (IDB, World Bank development indicators (WB, and the Central Bank of Bahrain (CBB annual reports.This study employs the Johansen and Juselius Cointegration test and Vector Error Correction Model (VECM as well as Vector Autoregressive model (VAR to reveal the long run and short-run causality between the dual banking development and non-Oil GDP growth. The VECM results of the conventional banking show that there is long-run bidirectional causality between all the conventional banking selected indicators and the non-Oil GDP. For the Islamic banking VAR model, there is a unidirectional causality from Islamic banking indicators to the non-oil GDP. There is no evidence on the role of non-oil GDP on the Islamic banking development. Impulse response functions in the two models shows that through one standards deviation positive shock in Islamic vs. Conventional Credit provided to private sector, the non-Oil GDP will be much higher in the next five years if we stimulate the Islamic credit provided to private sector than the conventional banks.Moreover, the Islamic credit provided to the private sector appears to be more procyclical than the credit provided by the conventional banks. However, the fluctuations in the conventional credit are sharper than the Islamic banks’ private credit. This study provides the policy makers in Bahrain with the appropriate evidences to design their policies in fostering the non-Oil sector.

  4. Electric power system basics for the nonelectrical professional

    CERN Document Server

    Blume, Steven W

    2016-01-01

    The second edition of Steven W. Blume’s bestseller provides a comprehensive treatment of power technology for the non-electrical engineer working in the electric power industry. This book aims to give non-electrical professionals a fundamental understanding of large interconnected electrical power systems, better known as the “Power Grid”, with regard to terminology, electrical concepts, design considerations, construction practices, industry standards, control room operations for both normal and emergency conditions, maintenance, consumption, telecommunications and safety. The text begins with an overview of the terminology and basic electrical concepts commonly used in the industry then it examines the generation, transmission and distribution of power. Other topics discussed include energy management, conservation of electrical energy, consumption characteristics and regulatory aspects to help readers understand modern electric power systems.

  5. Integrated Photovoltaic System Used as an Alternative Power Source

    Directory of Open Access Journals (Sweden)

    Ionel Laurentiu Alboteanu

    2014-09-01

    Full Text Available This paper presents a solution to use solar energy as an alternative source of electricity to conventional sources. The solution is to use a compact photovoltaic system integrated into a micro smart grid. The studied photovoltaic system is used into concrete application for the power supply lighting in a didactic laboratory.

  6. Studies of Non-Conventional Configuration Closed Electron Drift Thrusters

    International Nuclear Information System (INIS)

    Y. Raitses; D. Staack; A. Smirnov; A.A. Litvak; L.A. Dorf; T. Graves; N.J. Fisch

    2001-01-01

    In this paper, we review recent results obtained for segmented electrode and cylindrical Hall thrusters. A low sputtering graphite segmented electrode, placed at the exit of the annular thruster, is shown to affect the plasma potential distribution in the ceramic channel. This effect appears to be correlated with an observed plume reduction compared to a conventional, nonsegmented thruster. In preliminary experiments a 3-cm thruster was operated in the 50-200 W power range. Two operating regimes, stable and oscillating, were observed and investigated

  7. User requirement analysis of social conventions learning applications for Non-natives and low-literates

    NARCIS (Netherlands)

    Schouten, D.; Smets, N.; Driessen, M.; Hanekamp, M.; Cremers, A.H.M.; Neerincx, M.A.

    2013-01-01

    Learning and acting on social conventions is problematic for low-literates and non-natives, causing problems with societal participation and citizenship. Using the Situated Cognitive Engineering method, requirements for the design of social conventions learning software are derived from demographic

  8. Safety assessment of emergency electric power systems for nuclear power plants

    International Nuclear Information System (INIS)

    1986-09-01

    This paper is intended to assist the safety assessor within a regulatory body, or one working as a consultant, in assessing a given design of the Emergency Electrical Power System. Those non-electric power systems which may be used in a plant design to serve as emergency energy sources are addressed only in their general safety aspects. The paper thus relates closely to Safety Series 50-SG-D7 ''Emergency Power Systems at Nuclear Power Plants'' (1982), as far as it addresses emergency electric power systems. Several aspects are dealt with: the information the assessor may expect from the applicant to fulfill his task of safety review; the main questions the reviewer has to answer in order to determine the compliance with requirements of the NUSS documents; the national or international standards which give further guidance on a certain system or piece of equipment; comments and suggestions which may help to judge a variety of possible solutions

  9. WORKING PARK-FUEL CELL COMBINED HEAT AND POWER SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Allan Jones

    2003-09-01

    This report covers the aims and objectives of the project which was to design, install and operate a fuel cell combined heat and power (CHP) system in Woking Park, the first fuel cell CHP system in the United Kingdom. The report also covers the benefits that were expected to accrue from the work in an understanding of the full technology procurement process (including planning, design, installation, operation and maintenance), the economic and environmental performance in comparison with both conventional UK fuel supply and conventional CHP and the commercial viability of fuel cell CHP energy supply in the new deregulated energy markets.

  10. 30 CFR 75.206 - Conventional roof support.

    Science.gov (United States)

    2010-07-01

    ... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.206 Conventional roof support. (a) Except in anthracite mines using non-mechanized mining systems, when conventional roof support... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Conventional roof support. 75.206 Section 75...

  11. Corrosion products in power generating systems

    International Nuclear Information System (INIS)

    Lister, D.H.

    1980-06-01

    The important mechanisms of corrosion and corrosion product movement and fouling in the heat transport systems of thermal electric generating stations are reviewed. Oil- and coal-fired boilers are considered, along with nuclear power systems - both direct and indirect cycle. Thus, the fireside and waterside in conventional plants, and the primary coolant and steam-raising circuits in water-cooled reactors, are discussed. Corrosion products in organic- and liquid-metal-cooled reactors also are shown to cause problems if not controlled, while their beneficial effects on the cooling water side of condensers are described. (auth)

  12. Thermo-economic analysis of an integrated solar power generation system using nanofluids

    International Nuclear Information System (INIS)

    Alashkar, Adnan; Gadalla, Mohamed

    2017-01-01

    Highlights: • Develop a thermo-economic analysis of an integrated solar-power generation system. • A thermodynamic optimization is proposed to maximize system performance. • Select the optimum nanofluid to replace conventional heating fluids inside a PTSC. • Study the effect of thermal energy storage on performance and cost of the system. • Perform monthly and daily analyses to analyze system behavior using nanofluids. - Abstract: In this paper, a thermo-economic analysis of an Integrated Solar Regenerative Rankine Cycle (ISRRC) is performed. The ISRRC consists of a nanofluid-based Parabolic Trough Solar Collector (PTSC), and a Thermal Energy Storage System (TES) integrated with a Regenerative Rankine Cycle. The effect of dispersing metallic and non-metallic nanoparticles into conventional heating fluids on the output performance and cost of the ISRRC is studied for different volume fractions and for three modes of operation. The first mode assumes no storage, while the second and the third assume a storage system with a storage period of 7.5 h and 10 h respectively. For the modes of operation with the TES, the charging and discharging cycles are explained. The results show that the presence of the nanoparticles leads to an increase in the overall energy produced by the ISRRC for all modes of operation, causing a decrease in the Levelized Cost of Electricity (LEC), and an increase in the net savings of the ISRRC. After comparing the three modes of operation, it is established that the existence of a storage system leads to a higher power generation, and a lower LEC; however, the efficiency of the cycle drops. It is seen that the maximum increase in the annual energy output of the ISRRC caused by the addition of Cu nanoparticles to Syltherm 800 is approximately 3.1%, while the maximum increase in the net savings is about 2.4%.

  13. Performance enhancement of photovoltaic array through string and central based MPPT system under non-uniform irradiance conditions

    International Nuclear Information System (INIS)

    Syafaruddin; Karatepe, Engin; Hiyama, Takashi

    2012-01-01

    Highlights: ► We propose MPPT method for tracking global MPP of PV arrays under non-uniform irradiance conditions. ► We compare the performance of string and central based MPPT. ► Intelligent control method is utilized to identify the global operating voltage in string and central based MPPT system. ► The performance of proposed method is tested on different size of PV. - Abstract: Mismatching losses reduction of photovoltaic (PV) array has been intensively discussed through the increasing penetration of residential and commercial PV systems. Many causes of mismatching losses have been identified and plenty of proposed methods to solve this problem have been recently proposed. This paper deals with reducing method of mismatching losses due to the non-uniform irradiance conditions. It is well-known that a certain number of multiple peaks occur on the power–voltage curve as the number of PV modules in one-string increases under non-uniform operating conditions. Since the conventional control method only drives the operating points of PV system to the local maxima close to open circuit voltage, only small portion of power can be extracted from the PV system. In this study, a radial basis function neural network (RBF-ANN) based intelligent control method is utilized to map the global operating voltage and non-irradiance operating condition in string and central based MPPT systems. The proposed method has been tested on 10 × 3 (2.2 kW), 15 × 3 (2.5 kW) and 20 × 3 (3.3 kW) of series–parallel PV array configuration under random-shaded and continuous-shaded patterns. The proposed method is compared with the ideal case and conventional method through a simple power–voltage curve of PV arrays. The simulation results show that there are significant increases of about 30–60% of the extracted power in one operating condition when the proposed method is able to shift the operating voltage of modules to their optimum voltages.

  14. Alternative off-site power supply improves nuclear power plant safety

    International Nuclear Information System (INIS)

    Gjorgiev, Blaže; Volkanovski, Andrija; Kančev, Duško; Čepin, Marko

    2014-01-01

    Highlights: • Additional power supply for mitigation of the station blackout event in NPP is used. • A hydro power plant is considered as an off-site alternative power supply. • An upgrade of the probabilistic safety assessment from its traditional use is made. • The obtained results show improvement of nuclear power plant safety. - Abstract: A reliable power system is important for safe operation of the nuclear power plants. The station blackout event is of great importance for nuclear power plant safety. This event is caused by the loss of all alternating current power supply to the safety and non-safety buses of the nuclear power plant. In this study an independent electrical connection between a pumped-storage hydro power plant and a nuclear power plant is assumed as a standpoint for safety and reliability analysis. The pumped-storage hydro power plant is considered as an alternative power supply. The connection with conventional accumulation type of hydro power plant is analysed in addition. The objective of this paper is to investigate the improvement of nuclear power plant safety resulting from the consideration of the alternative power supplies. The safety of the nuclear power plant is analysed through the core damage frequency, a risk measure assess by the probabilistic safety assessment. The presented method upgrades the probabilistic safety assessment from its common traditional use in sense that it considers non-plant sited systems. The obtained results show significant decrease of the core damage frequency, indicating improvement of nuclear safety if hydro power plant is introduced as an alternative off-site power source

  15. Damping of Low Frequency Oscillation in Power System using Robust Control of Superconductor Flywheel Energy Storage System

    International Nuclear Information System (INIS)

    Lee, Jung Pil; Kim, Han Gun

    2012-01-01

    In this paper, the robust superconductor flywheel energy storage system(SFESS) controller using H control theory was designed to damp low frequency oscillation of power system. The main advantage of the controller is that uncertainties of power system can be included at the stage of controller design. Both disturbance attenuation and robust stability for the power system were treated simultaneously by using mixed sensitivity problem. The robust stability and the performance for uncertainties of power system were represented by frequency weighted transfer function. To verify control performance of proposed SFESS controller using control, the closed loop eigenvalue and the damping ratio in dominant oscillation mode of power system were analyzed and nonlinear simulation for one-machine infinite bus system was performed under disturbance for various operating conditions. The results showed that the proposed SFESS controller was more robust than conventional power system stabilizer (PSS).

  16. PyPSA: Python for Power System Analysis

    Directory of Open Access Journals (Sweden)

    Thomas Brown

    2018-01-01

    Full Text Available Python for Power System Analysis (PyPSA is a free software toolbox for simulating and optimising modern electrical power systems over multiple periods. PyPSA includes models for conventional generators with unit commitment, variable renewable generation, storage units, coupling to other energy sectors, and mixed alternating and direct current networks. It is designed to be easily extensible and to scale well with large networks and long time series. In this paper the basic functionality of PyPSA is described, including the formulation of the full power flow equations and the multi-period optimisation of operation and investment with linear power flow equations. PyPSA is positioned in the existing free software landscape as a bridge between traditional power flow analysis tools for steady-state analysis and full multi-period energy system models. The functionality is demonstrated on two open datasets of the transmission system in Germany (based on SciGRID and Europe (based on GridKit.   Funding statement: This research was conducted as part of the CoNDyNet project, which is supported by the German Federal Ministry of Education and Research under grant no. 03SF0472C. The responsibility for the contents lies solely with the authors

  17. Benveniste’s Experiments Explained by a Non-Conventional Experimenter Effect

    Directory of Open Access Journals (Sweden)

    Francis Beauvais

    2018-03-01

    Full Text Available Background: Benveniste’s biology experiments suggested the existence of molecular-like effects without molecules (“memory of water”. In this article, it is proposed that these disputed experiments could have been the consequence of a previously unnoticed and non-conventional experimenter effect. Methods: A probabilistic modelling is built in order to describe an elementary laboratory experiment. A biological system is modelled with two possible states (“resting” and “activated” and exposed to two experimental conditions labelled “control” and “test”, but both are biologically inactive. The modelling takes into account not only the biological system, but also the experimenters. In addition, an outsider standpoint is adopted to describe the experimental situation. Results: A classical approach suggests that, after experiment completion, the “control” and “test” labels of biologically-inactive conditions should both be associated with the “resting” state (i.e., no significant relationship between labels and system states. However, if the fluctuations of the biological system are also considered, a quantum-like relationship emerges and connects labels and system states (analogous to a biological “effect” without molecules. Conclusions: No hypotheses about water properties or other exotic explanations are needed to describe Benveniste’s experiments, including their unusual features. This modelling could be extended to other experimental situations in biology, medicine, and psychology.

  18. Process control in conventional power plants. The use of computer systems

    Energy Technology Data Exchange (ETDEWEB)

    Schievink, A; Woehrle, G

    1989-03-01

    To process information man can use his knowledge and his experience. Both these means however, permit only slow flows of information (about 25 bit/s) to be processed. The flow of information in a modern 700-MW-coal power station that the staff has to face is about 5000 bit per second, i.e. 200 times as much as a single human brain can process. One therefore needs modern computer-controlled process control systems which support the staff in recognizing and processing the complicated and rapid processes in such a way that the servicing staff is efficiently supported. The computer-man interface is ergonomically improved by visual display units.

  19. Development of lightweight radiators for lunar based power systems

    International Nuclear Information System (INIS)

    Juhasz, A.J.; Bloomfield, H.S.

    1994-05-01

    This report discusses application of a new lightweight carbon-carbon (C-C) space radiator technology developed under the NASA Civil-Space Technology Initiative (CSTI) High Capacity Power Program to a 20 kWe lunar based power system. This system comprises a nuclear (SP-100 derivative) heat source, a Closed Brayton Cycle (CBC) power conversion unit with heat rejection by means of a plane radiator. The new radiator concept is based on a C-C composite heat pipe with integrally woven fins and a thin walled metallic liner for containment of the working fluid. Using measured areal specific mass values (1.5 kg/m2) for flat plate radiators, comparative CBC power system mass and performance calculations show significant advantages if conventional heat pipes for space radiators are replaced by the new C-C heat pipe technology

  20. Artificial Neural Network Application for Power Transfer Capability and Voltage Calculations in Multi-Area Power System

    Directory of Open Access Journals (Sweden)

    Palukuru NAGENDRA

    2010-12-01

    Full Text Available In this study, the use of artificial neural network (ANN based model, multi-layer perceptron (MLP network, to compute the transfer capabilities in a multi-area power system was explored. The input for the ANN is load status and the outputs are the transfer capability among the system areas, voltage magnitudes and voltage angles at concerned buses of the areas under consideration. The repeated power flow (RPF method is used in this paper for calculating the power transfer capability, voltage magnitudes and voltage angles necessary for the generation of input-output patterns for training the proposed MLP neural network. Preliminary investigations on a three area 30-bus system reveal that the proposed model is computationally faster than the conventional method.

  1. Applying reliability analysis to design electric power systems for More-electric aircraft

    Science.gov (United States)

    Zhang, Baozhu

    The More-Electric Aircraft (MEA) is a type of aircraft that replaces conventional hydraulic and pneumatic systems with electrically powered components. These changes have significantly challenged the aircraft electric power system design. This thesis investigates how reliability analysis can be applied to automatically generate system topologies for the MEA electric power system. We first use a traditional method of reliability block diagrams to analyze the reliability level on different system topologies. We next propose a new methodology in which system topologies, constrained by a set reliability level, are automatically generated. The path-set method is used for analysis. Finally, we interface these sets of system topologies with control synthesis tools to automatically create correct-by-construction control logic for the electric power system.

  2. `Power storage system` dealing with leveling of electric power use; Denryoku riyo no heijunka ni kotaeru `denryoku chozo system`

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, M. [Meidensha Corp., Tokyo (Japan)

    1996-06-28

    An overview is given on the development situation of a Zn-Br battery as a power storage system. The system is aimed at storing excess power at night and supplying the on-load demand during daytime. The power storage technology requires a large output and capacity of MWh level, long term stability and durability, and cost as low as pumped storage power generation. Four kinds of batteries have been examined to cope with the conditions, in which development of Zn-Br batteries along with Na-S batteries is in progress towards practicability. As a power conversion method for this system, GTO has been employed for a large capacity unit and IGBT for a medium/small capacity unit. The reliability of the Zn-Br batteries against leakage was improved by laminating each cell by hot plate welding. The service life was improved by using a material with a high bromine resistance in place of the conventional electrode constituent material. Although the battery efficiency was influenced by each resistance of electrode, film and electrolytic solution, distance between electrodes, temperature, etc., these correlations were clarified so as to establish the simulation technology. At present, the system realizes 50kW and 40kWh/m{sup 3}. 1 ref., 8 figs.

  3. A robust control strategy for mitigating renewable energy fluctuations in a real hybrid power system combined with SMES

    Science.gov (United States)

    Magdy, G.; Shabib, G.; Elbaset, Adel A.; Qudaih, Yaser; Mitani, Yasunori

    2018-05-01

    Utilizing Renewable Energy Sources (RESs) is attracting great attention as a solution to future energy shortages. However, the irregular nature of RESs and random load deviations cause a large frequency and voltage fluctuations. Therefore, in order to benefit from a maximum capacity of the RESs, a robust mitigation strategy of power fluctuations from RESs must be applied. Hence, this paper proposes a design of Load Frequency Control (LFC) coordinated with Superconducting Magnetic Energy Storage (SMES) technology (i.e., an auxiliary LFC), using an optimal PID controller-based Particle Swarm Optimization (PSO) in the Egyptian Power System (EPS) considering high penetration of Photovoltaics (PV) power generation. Thus, from the perspective of LFC, the robust control strategy is proposed to maintain the nominal system frequency and mitigating the power fluctuations from RESs against all disturbances sources for the EPS with the multi-source environment. The EPS is decomposed into three dynamics subsystems, which are non-reheat, reheat and hydro power plants taking into consideration the system nonlinearity. The results by nonlinear simulation Matlab/Simulink for the EPS combined with SMES system considering PV solar power approves that, the proposed control strategy achieves a robust stability by reducing transient time, minimizing the frequency deviations, maintaining the system frequency, preventing conventional generators from exceeding their power ratings during load disturbances, and mitigating the power fluctuations from the RESs.

  4. Power-law tails and non-Markovian dynamics in open quantum systems: An exact solution from Keldysh field theory

    Science.gov (United States)

    Chakraborty, Ahana; Sensarma, Rajdeep

    2018-03-01

    The Born-Markov approximation is widely used to study the dynamics of open quantum systems coupled to external baths. Using Keldysh formalism, we show that the dynamics of a system of bosons (fermions) linearly coupled to a noninteracting bosonic (fermionic) bath falls outside this paradigm if the bath spectral function has nonanalyticities as a function of frequency. In this case, we show that the dissipative and noise kernels governing the dynamics have distinct power-law tails. The Green's functions show a short-time "quasi"-Markovian exponential decay before crossing over to a power-law tail governed by the nonanalyticity of the spectral function. We study a system of bosons (fermions) hopping on a one-dimensional lattice, where each site is coupled linearly to an independent bath of noninteracting bosons (fermions). We obtain exact expressions for the Green's functions of this system, which show power-law decay ˜|t - t'|-3 /2 . We use these to calculate the density and current profile, as well as unequal-time current-current correlators. While the density and current profiles show interesting quantitative deviations from Markovian results, the current-current correlators show qualitatively distinct long-time power-law tails |t - t'|-3 characteristic of non-Markovian dynamics. We show that the power-law decays survive in the presence of interparticle interaction in the system, but the crossover time scale is shifted to larger values with increasing interaction strength.

  5. A Mitigation Technique of High-Power MAI in the Multimedia Optical CDMA System with the Optical Power Selector

    Science.gov (United States)

    Ohba, Kohki; Miyazawa, Takaya; Sasase, Iwao

    In this paper, we propose a mitigation system of high-level multiple access interference (MAI) for multimedia optical Code-Division Multiple-Access (CDMA) systems using the optical power selector (OPS). The proposed system can eliminate high-intensity MAI at the receiver for low-priority users. Moreover, the proposed system can reduce by half the required number of code sequences compared to the conventional scheme. As a result, the proposed system can increase the number of weights at the same code-length and, thus, obtain higher code spreading gain. We analyze performances of the proposed system and show that both high-priority users and low-priority users achieve lower bit error rates in comparison to the conventional scheme.

  6. Study on a non-powered heat transporting system; Mudoryoku netsu hanso system ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Y [Kanto Gakuin University, Yokohama (Japan)

    1997-11-25

    This paper proposes a non-powered heat transportation (HT) system. The system is composed of an evaporator, condenser, receiver, switching chamber (SC) and 3 check valves which are connected with each other by vapor and liquid tubes. Condensed liquid supercooled in the condenser exists in the receiver forming a saturated condition at a concerned temperature, and condensed liquid is lifted up from the condenser to the receiver by pressure difference between the evaporator and receiver. Generally evaporation pressure is higher by pressure difference between liquid levels in the condenser and receiver. The lifted up amount of condensed liquid increases with evaporation pressure, resulting in an increase in heating surface area of the condenser and amount of condensed liquid. A proper evaporator pressure is thus retained by reduction of evaporation pressure. SC is connected with the receiver and evaporator, and switches high- and low-pressure valves by motion of an inner float to transport heat from the evaporator to condenser. Reverse HT is possible as normal latent HT by installing a bypass. Some problems are also described. 2 refs., 8 figs.

  7. COMPARATIVE ANALYSIS ON PERFORMANCE OF POWER CONVERTERSFOR MPPT USING PAO TECHNIQUE

    OpenAIRE

    Dr. S. Rajeswari*

    2017-01-01

    This research work is mainly spotlight to identify a suitable power converter for tracking the Maximum Power Point, an analysis of MPPT based power converters has been carried out in this work. A PV system is a non-linear power source due to the variations in the climatic conditions, hence tracking the maximum power point is difficult. It mainly explains about the PAO algorithm based MPPT method to track the maximum power. It also discuss about different types of conventional power converters...

  8. A Three-Port Topology Comparison for a Low Power Stand-Alone Photovoltaic System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using c...... component stress factor (CSF) is performed, which gives a quantitative measure of the performance of the converter. The candidate topologies are compared to each other according to a defined LED lighting strategy and a solar irradiation profile.......Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using...

  9. The establishment of Digital Image Capture System(DICS) using conventional simulator

    International Nuclear Information System (INIS)

    Oh, Tae Sung; Park, Jong Il; Byun, Young Sik; Shin, Hyun Kyoh

    2004-01-01

    The simulator is used to determine patient field and ensure the treatment field, which encompasses the required anatomy during patient normal movement such as during breathing. The latest simulator provide real time display of still, fluoroscopic and digitalized image, but conventional simulator is not yet. The purpose of this study is to introduce digital image capture system(DICS) using conventional simulator and clinical case using digital captured still and fluoroscopic image. We connect the video signal cable to the video terminal in the back up of simulator monitor, and connect the video jack to the A/D converter. After connection between the converter jack and computer, We can acquire still image and record fluoroscopic image with operating image capture program. The data created with this system can be used in patient treatment, and modified for verification by using image processing software. (j.e. photoshop, paintshop) DICS was able to establish easy and economical procedure. DCIS image was helpful for simulation. DICS imaging was powerful tool in the evaluation of the department specific patient positioning. Because the commercialized simulator based of digital capture is very expensive, it is not easily to establish DICS simulator in the most hospital. DICS using conventional simulator enable to utilize the practical use of image equal to high cost digitalized simulator and to research many clinical cases in case of using other software program.

  10. The Burning Plasma Experiment conventional facilities

    International Nuclear Information System (INIS)

    Commander, J.C.

    1991-01-01

    The Burning Program Plasma Experiment (BPX) is phased to start construction of conventional facilities in July 1994, in conjunction with the conclusion of the Tokamak Fusion Test Reactor (TFTR) project. This paper deals with the conceptual design of the BPX Conventional Facilities, for which Functional and Operational Requirements (F ampersand ORs) were developed. Existing TFTR buildings and utilities will be adapted and used to satisfy the BPX Project F ampersand ORs to the maximum extent possible. However, new conventional facilities will be required to support the BPX project. These facilities include: The BPX building; Site improvements and utilities; the Field Coil Power Conversion (FCPC) building; the TFTR modifications; the Motor Generation (MG) building; Liquid Nitrogen (LN 2 ) building; and the associated Instrumentation and Control (I ampersand C) systems. The BPX building will provide for safe and efficient shielding, housing, operation, handling, maintenance and decontamination of the BPX and its support systems. Site improvements and utilities will feature a utility tunnel which will provide a space for utility services--including pulse power duct banks and liquid nitrogen coolant lines. The FCPC building will house eight additional power supplied for the Toroidal Field (TF) coils. The MG building will house the two MG sets larger than the existing TFTR MG sets. This paper also addresses the conventional facility cost estimating methodology and the rationale for the construction schedule developed. 6 figs., 1 tab

  11. Conventional RF system design

    International Nuclear Information System (INIS)

    Puglisi, M.

    1994-01-01

    The design of a conventional RF system is always complex and must fit the needs of the particular machine for which it is planned. It follows that many different design criteria should be considered and analyzed, thus exceeding the narrow limits of a lecture. For this reason only the fundamental components of an RF system, including the generators, are considered in this short seminar. The most common formulas are simply presented in the text, while their derivations are shown in the appendices to facilitate, if desired, a more advanced level of understanding. (orig.)

  12. Analysis of the spontaneous variations in wind power and necessary continuous regulation of hydro-electric and thermal power, related to a future Swedish power system

    Energy Technology Data Exchange (ETDEWEB)

    Holm, J O; Lindstrom, P O

    1982-09-01

    Wind power is unlike conventional electric power generation, since the output fluctuates uncontrollably. These fluctuations must be balanced by controlled generation from other power sources. This will create new and interesting demands on the reserves in the power system. The short-term fluctuations have a low simultaneity factor and must be balanced by an automatic frequency control reserve. In Sweden, this consists of automatically controlled hydro-electric power. The report contains calculations of the amount by which the demand on reserves will increase when wind power is introduced.

  13. Uninterrupted thermoelectric energy harvesting using temperature-sensor-based maximum power point tracking system

    International Nuclear Information System (INIS)

    Park, Jae-Do; Lee, Hohyun; Bond, Matthew

    2014-01-01

    Highlights: • Feedforward MPPT scheme for uninterrupted TEG energy harvesting is suggested. • Temperature sensors are used to avoid current measurement or source disconnection. • MPP voltage reference is generated based on OCV vs. temperature differential model. • Optimal operating condition is maintained using hysteresis controller. • Any type of power converter can be used in the proposed scheme. - Abstract: In this paper, a thermoelectric generator (TEG) energy harvesting system with a temperature-sensor-based maximum power point tracking (MPPT) method is presented. Conventional MPPT algorithms for photovoltaic cells may not be suitable for thermoelectric power generation because a significant amount of time is required for TEG systems to reach a steady state. Moreover, complexity and additional power consumption in conventional circuits and periodic disconnection of power source are not desirable for low-power energy harvesting applications. The proposed system can track the varying maximum power point (MPP) with a simple and inexpensive temperature-sensor-based circuit without instantaneous power measurement or TEG disconnection. This system uses TEG’s open circuit voltage (OCV) characteristic with respect to temperature gradient to generate a proper reference voltage signal, i.e., half of the TEG’s OCV. The power converter controller maintains the TEG output voltage at the reference level so that the maximum power can be extracted for the given temperature condition. This feedforward MPPT scheme is inherently stable and can be implemented without any complex microcontroller circuit. The proposed system has been validated analytically and experimentally, and shows a maximum power tracking error of 1.15%

  14. Power system reliability enhancement by using PowerformerTM

    Directory of Open Access Journals (Sweden)

    Rahmat-Allah Hooshmand

    2009-01-01

    Full Text Available A high-voltage generator PowerformerTM is a new generation of the AC generators. The most significant advantages of these PowerformerTM are their direct connection to high-voltage grid, higher availability, and more reactive power margin, short term overloading capacity and removing the power transformer from the structure of the power plant. In this paper, the installation effect of these generators on the power system reliability is investigated. The amount of the effects depends on the type and location of the power plant, location of the PowerformerTM, the size of load and network topology. For this purpose, in the 6-bus IEEE RBTS system, the conventional generators are replaced by these new PowerformerTM and then, the reliability indices are evaluated. The simulation results show that the reliability indices such as the expected duration of load curtailment (EDLC and the expected energy not served (EENS are improved. .

  15. Evolution of Onsite and Offsite Power Systems in US Nuclear Power Plants

    International Nuclear Information System (INIS)

    Mathew, Roy K.

    2015-01-01

    The AC electric power system is the source of power for station auxiliaries during normal operation and for the reactor protection system and emergency safety features during abnormal and accident conditions. Since the construction of early plants in US, the functional adequacy and requirements of the offsite power systems, safety and non safety related onsite electric power systems have changed considerably to ensure that these systems have adequate redundancy, independence, quality, maintenance and testability to support safe shutdown of the nuclear plant. The design of AC systems has evolved from a single train to multiple (up to four) redundant trains in the current evolutionary designs coupled with other auxiliary AC systems. The early plants were designed to cope with a Loss of Offsite Power (LOOP) event through the use of onsite power supplies only. However operating experience has indicated that onsite and offsite power AC power systems can fail due to natural phenomena (earthquakes, lightning strikes, fires, geomagnetic storms, tsunamis, etc.) or operational abnormalities such as loss of a single phase, switching surges or human error. The onsite DC systems may not be adequately sized to support plant safe shutdown over an extended period if AC power cannot be restored within a reasonable time. This paper will discuss the requirements to improve availability and reliability of offsite and onsite alternating current (AC) power sources to U.S. Nuclear Power Plants. In addition, the paper will discuss the requirements and guidance beyond design basis events. (author)

  16. Power quality control of an autonomous wind-diesel power system based on hybrid intelligent controller.

    Science.gov (United States)

    Ko, Hee-Sang; Lee, Kwang Y; Kang, Min-Jae; Kim, Ho-Chan

    2008-12-01

    Wind power generation is gaining popularity as the power industry in the world is moving toward more liberalized trade of energy along with public concerns of more environmentally friendly mode of electricity generation. The weakness of wind power generation is its dependence on nature-the power output varies in quite a wide range due to the change of wind speed, which is difficult to model and predict. The excess fluctuation of power output and voltages can influence negatively the quality of electricity in the distribution system connected to the wind power generation plant. In this paper, the authors propose an intelligent adaptive system to control the output of a wind power generation plant to maintain the quality of electricity in the distribution system. The target wind generator is a cost-effective induction generator, while the plant is equipped with a small capacity energy storage based on conventional batteries, heater load for co-generation and braking, and a voltage smoothing device such as a static Var compensator (SVC). Fuzzy logic controller provides a flexible controller covering a wide range of energy/voltage compensation. A neural network inverse model is designed to provide compensating control amount for a system. The system can be optimized to cope with the fluctuating market-based electricity price conditions to lower the cost of electricity consumption or to maximize the power sales opportunities from the wind generation plant.

  17. POWER-GEN '90 conference papers: Volume 3 (Environmental trends and issues) and Volume 4 (Case histories - Non-utility power generation)

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    This is book 2 of a collection of papers presented at the Third International Power Generation Industries Conference on December 4-6, 1990. The book contains Volume 3, Environmental Trends and Issues, and Volume 4, Case Histories - Non-utility Power Generation. The topics of the papers include environmental legislative and regulatory trends, acid rain compliance strategies and technologies, other global environmental concerns, gas fired systems, solid and waste fuels, despatching and wheeling, and strategies for purchasing non-utility power

  18. Non conventional hydrocarbons in Maghreb - an announced ecocide

    International Nuclear Information System (INIS)

    Balvet, Jacqueline; Espagne, Vincent; Rondeleux, Nejma; Dupont, Stephane

    2015-01-01

    Whereas gas and oil companies did not succeed in the development of shale gas exploration and exploitation in Europe for different reasons (citizen mobilisation against these projects, resources much smaller than expected), these companies are looking in other directions, notably the Maghreb region (North Africa) which is an important hydrocarbon supplier for European countries. This publication proposes an overview of the situation in Algeria, Morocco and Tunisia regarding this exploitation. It first recalls health and pollution impacts and consequences of hydraulic fracturing, and also the impact of hydrocarbon consumption on climate change. It indicates assessments made by the EIA of resources of shale gas and shale oil in the three countries, and outlines that these assessments might be too high as it has been the case in other countries. An overview of the situation of the three countries is then proposed, starting with Algeria: the third world shale gas reserve, presence of Total and GDF-Suez as investors with Sonatrach (the Algerian company) keeping a large majority, existence of a law which authorises the exploitation of non conventional hydrocarbons, and a very strong mobilisation of populations in the Algerian Sahara. The case of Morocco is then addressed: high dependence on imports but important non conventional reserves, exploitation of several sites, good conditions awarded to multinational companies, a focus on two important investors (Chevron and Repsol), start of a citizen mobilisation. The case of Tunisia is finally addressed: discovery of 'miraculous' deposits, overview of investors, a new but absolutely iniquitous legal framework, mobilisation of local associations

  19. Power system technologies for the manned Mars mission

    International Nuclear Information System (INIS)

    Bents, D.; Patterson, M.J.; Berkopec, F.; Myers, I.; Presler, A.

    1986-01-01

    The high impulse of electric propulsion makes it an attractive option for manned interplanetary missions such as a manned mission to Mars. This option is, however, dependent on the availability of high energy sources for propulsive power in addition to that required for the manned interplanetary transit vehicle. Two power system technologies are presented: nuclear and solar. The ion thruster technology for the interplanetary transit vehicle is described for a typical mission. The power management and distribution system components required for such a mission must be further developed beyond today's technology status. High voltage-high current technology advancements must be achieved. These advancements are described. In addition, large amounts of waste heat must be rejected to the space environment by the thermal management system. Advanced concepts such as the liquid droplet radiator are discussed as possible candidates for the manned Mars mission. These thermal management technologies have great potential for significant weight reductions over the more conventional systems

  20. The RF power system for the SNS linac

    International Nuclear Information System (INIS)

    Tallerico, P.J.; Reass, W.A.

    1998-01-01

    The initial goal of the SNS project is to produce a 1 MW average beam of protons with short pulse lengths onto a neutron-producing target. The objective of the SNS RF system is to generate 117 MW peak of pulsed 805 MHz microwave power with an accelerated beam pulse length of 1.04 ms at a 60 Hz repetition rate. The power system must be upgradeable in peak power to deliver 2 MW average power to the neutron target. The RF system also requires about 3 MW peak of RF power at 402.5 MHz, but that system is not discussed here. The design challenge is to produce an RF system at minimum cost, that is very reliable and economical to operate. The combination of long pulses and high repetition rates make conventional solutions, such as the pulse transformer and transmission line method, very expensive. The klystron, with a modulating anode, and 1.5 MW of peak output power is the baseline RF amplifier, an 56 are required in the baseline design. The authors discuss four power system configurations that are the candidates for the design. The baseline design is a floating-deck modulating anode system. A second power system being investigated is the fast-pulsed power supply, that can be turned on and off with a rise time of under 0.1 ms. This could eliminate the need for a modulator, and drastically reduce the energy storage requirements. A third idea is to use a pulse transformer with a series IGBT switch and a bouncer circuit on the primary side, as was done for the TESLA modulator. A fourth method is to use a series IGBT switch at high voltage, and not use a pulse transformer. The authors discuss the advantages and problems of these four types of power systems, but they emphasize the first two

  1. A technology roadmap of smart biosensors from conventional glucose monitoring systems.

    Science.gov (United States)

    Shende, Pravin; Sahu, Pratiksha; Gaud, Ram

    2017-06-01

    The objective of this review article is to focus on technology roadmap of smart biosensors from a conventional glucose monitoring system. The estimation of glucose with commercially available devices involves analysis of blood samples that are obtained by pricking finger or extracting blood from the forearm. Since pain and discomfort are associated with invasive methods, the non-invasive measurement techniques have been investigated. The non-invasive methods show advantages like non-exposure to sharp objects such as needles and syringes, due to which there is an increase in testing frequency, improved control of glucose concentration and absence of pain and biohazard materials. This review study is aimed to describe recent invasive techniques and major noninvasive techniques, viz. biosensors, optical techniques and sensor-embedded contact lenses for glucose estimation.

  2. Systemic antimicrobial therapy (minocycline as an adjunct to non-surgical approach to recurrent chronic generalized gingival hyperplasia

    Directory of Open Access Journals (Sweden)

    Parag M Khatri

    2014-01-01

    Full Text Available Systemic antibiotic treatment has emerged as a powerful adjunct to conventional mechanical debridement for therapeutic management of the periodontal diseases. The conceptual basis for treating periodontal diseases as infections is particularly attractive in part because of substantial data indicating that these diseases may be associated with specific putative pathogens. Further, discrete groups of patients respond well to systemic antibiotics and exhibit improvement of clinical parameters, including attachment level and inflammation. This bacterial-host interaction, which is ever-so-present in periodontitis, directs us toward utilizing antimicrobial agents along with the routine mechanical debridement. This case report presents a case of a female patient with recurrence of the chronic generalized periodontitis with gingival enlargement, which is treated thrice by referral dentist. A through clinical examination was carried out pre-operatively and treatment was planned with systemic minocycline in conjunction with the conventional non-surgical approach. There was a significant reduction of pocket depth, gain in attachment with dramatic improvement clinically.

  3. Systemic antimicrobial therapy (minocycline) as an adjunct to non-surgical approach to recurrent chronic generalized gingival hyperplasia.

    Science.gov (United States)

    Khatri, Parag M; Bacha, Shraddanand

    2014-03-01

    Systemic antibiotic treatment has emerged as a powerful adjunct to conventional mechanical debridement for therapeutic management of the periodontal diseases. The conceptual basis for treating periodontal diseases as infections is particularly attractive in part because of substantial data indicating that these diseases may be associated with specific putative pathogens. Further, discrete groups of patients respond well to systemic antibiotics and exhibit improvement of clinical parameters, including attachment level and inflammation. This bacterial-host interaction, which is ever-so-present in periodontitis, directs us toward utilizing antimicrobial agents along with the routine mechanical debridement. This case report presents a case of a female patient with recurrence of the chronic generalized periodontitis with gingival enlargement, which is treated thrice by referral dentist. A through clinical examination was carried out pre-operatively and treatment was planned with systemic minocycline in conjunction with the conventional non-surgical approach. There was a significant reduction of pocket depth, gain in attachment with dramatic improvement clinically.

  4. How hybrid-electric vehicles are different from conventional vehicles: the effect of weight and power on fuel consumption

    International Nuclear Information System (INIS)

    Reynolds, C; Kandlikar, M

    2007-01-01

    An increasingly diverse set of hybrid-electric vehicles (HEVs) is now available in North America. The recent generation of HEVs have higher fuel consumption, are heavier, and are significantly more powerful than the first generation of HEVs. We compare HEVs for sale in the United States in 2007 to equivalent conventional vehicles and determine how vehicle weight and system power affects fuel consumption within each vehicle set. We find that heavier and more powerful hybrid-electric vehicles are eroding the fuel consumption benefit of this technology. Nonetheless, the weight penalty for fuel consumption in HEVs is significantly lower than in equivalent conventional internal combustion engine vehicles (ICEVs). A 100 kg change in vehicle weight increases fuel consumption by 0.7 l/100 km in ICEVs compared with 0.4 l/100 km in HEVs. When the HEVs are compared with their ICEV counterparts in an equivalence model that differentiates between cars and sports-utility vehicles, the average fuel consumption benefit was 2.7 l/100 km. This analysis further reveals that a HEV which is 100 kg heavier than an identical ICEV would have a fuel consumption penalty of 0.15 l/100 km. Likewise, an increase in the HEV's power by 10 kW results in a fuel consumption penalty of 0.27 l/100 km

  5. Achievement report for fiscal 1999 on project for supporting the formation of energy/environmental technology verification project. International joint verification research project (Use of combined binary power generation systems at new geothermal fields on Mindoro Island, the Philippines, and comparison with conventional power generation systems); 1999 nendo Philippines koku Mindoro to no shinki chinetsutai ni okeru combined binary hatsuden hoshiki no tekiyo seika hokokusho. Conventional hatsuden hoshiki tono hikaku kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Concerning the Manito Lowlands geothermal field and the Montelago geothermal field where the systems are to be newly installed, the geothermal reservoir characteristics are assessed, and cost effectiveness is compared between different power generating systems. According to the investigations conducted into the two geothermal fields in the past, they are supposed to have geothermal potentials of the medium grade. Chemical analyses are conducted anew on this occasion into the hot spring water and fumarole gas, and the MT (magnetotelluric) method is implemented for the survey of reservoir distribution. It is now expected that approximately 20MWe will be exploited from each of the two geothermal fields. The power generation systems studied are the single flash type and double flash type for the conventional power generation system, and the cascade type, bottoming type, and two-phase binary type for the combined binary power generation system. As the result, it is concluded that the double flash type or two-phase binary type will be advantageous to the Manito Lowlands geothermal field, and the double flash type or bottoming type or two-phase binary type will be advantageous to the Montelago geothermal field. (NEDO)

  6. Design and optimization of resonance-based efficient wireless power delivery systems for biomedical implants.

    Science.gov (United States)

    Ramrakhyani, A K; Mirabbasi, S; Mu Chiao

    2011-02-01

    Resonance-based wireless power delivery is an efficient technique to transfer power over a relatively long distance. This technique typically uses four coils as opposed to two coils used in conventional inductive links. In the four-coil system, the adverse effects of a low coupling coefficient between primary and secondary coils are compensated by using high-quality (Q) factor coils, and the efficiency of the system is improved. Unlike its two-coil counterpart, the efficiency profile of the power transfer is not a monotonically decreasing function of the operating distance and is less sensitive to changes in the distance between the primary and secondary coils. A four-coil energy transfer system can be optimized to provide maximum efficiency at a given operating distance. We have analyzed the four-coil energy transfer systems and outlined the effect of design parameters on power-transfer efficiency. Design steps to obtain the efficient power-transfer system are presented and a design example is provided. A proof-of-concept prototype system is implemented and confirms the validity of the proposed analysis and design techniques. In the prototype system, for a power-link frequency of 700 kHz and a coil distance range of 10 to 20 mm, using a 22-mm diameter implantable coil resonance-based system shows a power-transfer efficiency of more than 80% with an enhanced operating range compared to ~40% efficiency achieved by a conventional two-coil system.

  7. Soil Microbial Activity in Conventional and Organic Agricultural Systems

    Directory of Open Access Journals (Sweden)

    Romero F.V. Carneiro

    2009-06-01

    Full Text Available The aim of this study was to evaluate microbial activity in soils under conventional and organic agricultural system management regimes. Soil samples were collected from plots under conventional management (CNV, organic management (ORG and native vegetation (AVN. Soil microbial activity and biomass was significantly greater in ORG compared with CNV. Soil bulk density decreased three years after adoption of organic system. Soil organic carbon (SOC was higher in the ORG than in the CNV. The soil under organic agricultural system presents higher microbial activity and biomass and lower bulk density than the conventional agricultural system.

  8. Integrated environmental control concepts for advanced power systems

    International Nuclear Information System (INIS)

    Rubin, E.S.; Kalagnanam, J.R.; Berkenpas, M.B.

    1996-01-01

    For both conventional and advanced power systems, the capability to estimate the performance and cost of environmental control systems is critical to a variety of planning and analysis requirements faced by utilities, regulators, researchers and analysts in the public and private sectors. This paper describes a computer model developed for the U.S. Department of Energy (USDOE) to provide an up-to-date capability for analyzing a variety of pre-combustion, combustion, and post-combustion options in an integrated framework. A unique feature of the model allows performance and costs of integrated environmental control concepts to be modeled probabilistically as a means of characterizing uncertainties and risks. Examples are presented of model applications comparing conventional and advanced emission control designs. 13 refs, 6 figs, 5 tabs

  9. PSA methodology including new design, operational and safety factors, 'Level of recognition of phenomena with a presumed dominant influence upon operational safety' (failures of conventional as well as non-conventional passive components, dependent failures, influence of operator, fires and external threats, digital control, organizational factors)

    International Nuclear Information System (INIS)

    Jirsa, P.

    2001-10-01

    The document represents a specific type of discussion of existing methodologies for the creation and application of probabilistic safety assessment (PSA) in light of the EUR document summarizing requirements placed by Western European NPP operators on the future design of nuclear power plants. A partial goal of this discussion consists in mapping, from the PSA point of view, those selected design, operational and/or safety factors of future NPPs that may be entirely new or, at least, newly addressed. Therefore, the terms of reference for this stage were formulated as follows: Assess current level of knowledge and procedures in the analysis of factors and phenomena with a dominant influence upon operational safety of new generation reactors, especially in the following areas: (1) Phenomenology of failure types and mechanisms and reliability of conventional passive safety system components; (2) Phenomenology of failure types and mechanisms and reliability of non-conventional passive components of newly designed safety systems; (3) Phenomenology of types and mechanisms of dependent failures; (4) Human factor role in new generation reactors and its effect upon safety; (5) Fire safety and other external threats to new nuclear installations; (6) Reliability of the digital systems of the I and C system and their effect upon safety; and (7) Organizational factors in new nuclear installations. (P.A.)

  10. Allocation of synchronous condensers for restoration of system short-circuit power

    DEFF Research Database (Denmark)

    Marrazi, Emanuel; Yang, Guangya; Weinreich-Jensen, Peter

    2017-01-01

    Modern power systems, employing an increasing number of converter-based renewable energy sources (RES) and decreasing the usage of conventional power plants, are leading to lower levels of short-circuit power and rotational inertia. A solution to this is the employment of synchronous condensers...... in the grid, in order to provide sufficient short-circuit power. This results in the increase of the short-circuit ratio (SCR) at transmission system bus-bars serving as points of interconnection (POI) to renewable generation. Evaluation of the required capacity and grid-location of the synchronous condensers...... by renewable generation. Total cost of synchronous condenser installations in the system is minimized and the SCRs at the POIs of central renewable power plants are strengthened. The method has potential for application on larger grids, aiding grid-integration of RES....

  11. The non conventional gas, a factor of energy independence?

    International Nuclear Information System (INIS)

    Jacques Percebois

    2011-01-01

    As the recent exploitation of non conventional gases (or shale gases) has dramatically changed the energy deal in the USA, and therefore the energy world market, these gases seem to be a factor of energy independence for countries which possess such resources, but also create environmental constrains. The author describes how shale gas produces a technological revolution, and discusses how it can be a factor for the diversification of the energy mix, and above all a way to reconquer some energy independence

  12. Energy and environmental evaluation of combined cooling heating and power system

    Science.gov (United States)

    Bugaj, Andrzej

    2017-11-01

    The paper addresses issues involving problems of implementing combined cooling, heating and power (CCHP) system to industrial facility with well-defined demand profiles of cooling, heating and electricity. The application of CCHP system in this particular industrial facility is being evaluated by comparison with the reference system that consists of three conventional methods of energy supply: (a) electricity from external grid, (b) heat from gas-fired boilers and (c) cooling from vapour compression chillers run by electricity from the grid. The CCHP system scenario is based on the combined heat and power (CHP) plant with gas turbine-compressor arrangement and water/lithium bromide absorption chiller of a single-effect type. Those two scenarios are analysed in terms of annual primary energy usage as well as emissions of CO2. The results of the analysis show an extent of primary energy savings of the CCHP system in comparison with the reference system. Furthermore, the environmental impact of the CCHP usage, in the form of greenhouse gases emission reductions, compares quite favourably with the reference conventional option.

  13. Energy-Efficiency Analysis of Per-Subcarrier Antenna Selection with Peak-Power Reduction in MIMO-OFDM Wireless Systems

    Directory of Open Access Journals (Sweden)

    Ngoc Phuc Le

    2014-01-01

    Full Text Available The use of per-subcarrier antenna subset selection in OFDM wireless systems offers higher system capacity and/or improved link reliability. However, the implementation of the conventional per-subcarrier selection scheme may result in significant fluctuations of the average power and peak power across antennas, which affects the potential benefits of the system. In this paper, power efficiency of high-power amplifiers and energy efficiency in per-subcarrier antenna selection MIMO-OFDM systems are investigated. To deliver the maximum overall power efficiency, we propose a two-step strategy for data-subcarrier allocation. This strategy consists of an equal allocation of data subcarriers based on linear optimization and peak-power reduction via cross-antenna permutations. For analysis, we derive the CCDF (complementary cumulative distribution function of the power efficiency as well as the analytical expressions of the average power efficiency. It is proved from the power-efficiency perspective that the proposed allocation scheme outperforms the conventional scheme. We also show that the improvement in the power efficiency translates into an improved capacity and, in turn, increases energy efficiency of the proposed system. Simulation results are provided to validate our analyses.

  14. Prototype testing and analysis of a novel internal combustion linear generator integrated power system

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhaoping; Chang, Siqin [School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China)

    2010-04-15

    A novel four-stroke free-piston engine equipped with a linear electric generator (namely internal combustion linear generator integrated power system) is proposed in this paper to achieve efficient energy conversion from fuel to electricity. Unique features of the novel power system are presented and their effects on the continuous running are discussed, along with potential advantages and disadvantages compared to conventional engines. A single cylinder, gasoline and spark ignition prototype is fabricated with reference to the geometric and control parameters of an existing conventional four-stroke engine. Stable running of the prototype is realized, and a 2.2 kW average output power with the generating efficiency of 32% has been obtained up to now. The feasibility and performance of the proposed design are verified. Detailed testing results from the continuous running prototype are analyzed in this paper for giving insight into the performance and dynamic behaviors of the novel power system. (author)

  15. Non-Characteristic Harmonics Analysis of the ITER Pulsed Power Supply

    International Nuclear Information System (INIS)

    Yang Wei; Xu Liuwei; Fu Peng; Lu Huawei; Sheng Zhicai

    2009-01-01

    The ITER pulsed power supply system will be operated in non-ideal conditions including an asymmetric firing angle, an unbalanced AC supply and an unbalanced AC side impedance of the transformer. In this study the switching functions approach is used to calculate non-characteristic harmonics in ITER, possibly caused by an AC-DC convertor in non-ideal conditions. A PSCAD simulation model is set up to study the non-characteristic harmonics in those non-ideal conditions. It is found that the non-characteristic harmonic does appear and the simulation result is in accordance with the calculating strategy. (fusion engineering)

  16. Improvement of Transient Stability of Power System by System Damping Series Resistor (SDSR)

    OpenAIRE

    上里, 勝実; 千住, 智信; 当銘, 秀之; 高原, 景滋; Uezato, Katsumi; Senjyu, Tomonobu; Toume, Hideyuki; Takahara, Keiji

    1990-01-01

    The system damping resistor is one of the method for improving the transient stability of power systems. The main circuit is the simple construction so that is low cost and is few abnormal surge, and is superior in ability of economy, reliability and maintenance. Conventionally, most of all system damping resistors have adopted the paralleled resistor, whereas the series resistor is used little.In this paper, we investigate the characteristics of the series resistor by comparing with the para...

  17. Non-nuclear power sources for deep space

    Energy Technology Data Exchange (ETDEWEB)

    Kennel, E.B.; Tang, C.; Santarius, J.F.

    1998-07-01

    Electric propulsion and non-nuclear power can be used in tandem as a replacement for the current chemical booster and radioisotope thermoelectric generators now in use for deep space applications (i.e., to the asteroid belt and beyond). In current generation systems, electric propulsion is usually considered to be impractical because of the lack of high power for deep space, and non-nuclear power is thought to be impractical partly due to its high mass. However, when taken in combination, a solar powered electric upper stage can provide ample power and propulsion capability for use in deep space. Radioisotope thermoelectric generator (RTG) systems have generally been selected for missions only when other systems are absolutely unavailable. The disadvantages of radioisotopes include the need for nuclear safety as another dimension of concern in payload integration; the lack of assured availability of plutonium in the post-cold-war world; the enormous cost of plutonium-238; and the system complexity introduced by the need to continuously cool the system during the pre-launch phase. A conservative estimate for the total power for the solar array at beginning of life (BOL) may be in the range of 25 kW in order to provide 500 W continuous power at Jupiter. The availability of {approximately} 25 kW(e) in earth orbit raises the interesting possibility of coupling electric propulsion units to this free electric power. If electric propulsion is used to raise the probe from low-earth-orbit to an earth-escape trajectory, the system could actually save on low-earth orbit mass. Electric propulsion could be used by itself in a spiral trajectory orbit raising maneuver to earth escape velocity, or it could be used in conjunction with a chemical upper stage (either solid rocket or liquid), which would boost the payload to an elliptical orbit. The concept is to begin the Earth-Jupiter trip with a swing-by near the Sun close to the orbit of Venus and perhaps even closer if thermal

  18. Emergency power systems at nuclear power plants

    International Nuclear Information System (INIS)

    1991-01-01

    This Safety Guide was prepared as part of the Nuclear Safety Standards programme for establishing Codes and Safety Guides relating to nuclear power plants (NPPs). The first edition of the present Safety Guide was developed in the early 1980s. The text has now been brought up-to-date, refined in several details and amended to include non-electrical diverse and independent power sources. This Guide applies to NPP for which the total power supply comprises a normal power supply and an emergency power supply (EPS), which may be electrical or a combination of electrical and non-electrical. The Guide provides general guidance for all types of EPS and specific guidance on the design safety requirements and the features of the electrical and non-electrical portions of the EPS. 9 figs, 2 tabs

  19. Unbalance on power systems: a general review

    Energy Technology Data Exchange (ETDEWEB)

    Reineri, Claudio A.; Gomez Targarona, Juan C.

    2009-07-01

    A general revision of different aspects in relation to the voltage unbalance in electric power systems is presented, that should necessarily be deeply known by technical operators and designers of facilities, installations, and electric equipment. Dissimilar unbalance definitions, unbalance measurement methods, their quantification and the interpretation of such magnitudes are revised. The causes of the unbalances in electric power systems were described and analyzed. The effects on power systems are also studied, specially those that have influence on: system operability, lost of efficiency of the three phase system and their impact in the definitions of traditional power. Similarly is studied the unbalance effect on certain loads, in particular: three-phase motors, power electronics and ASD's. Also methods to locate the origin of these problems, as well as the different normative or standards, and possible methods to mitigate their effects are deeply detailed. It is concluded in the necessity to deepen the study of the power system unbalance, because numerous non resolved aspects still exist whose solution requires of a deep knowledge on the part of the involved professionals. (author)

  20. Radioisotope AMTEC power system designs for spacecraft applications

    International Nuclear Information System (INIS)

    Ivanenok, J.F. III; Sievers, R.K.; Hunt, T.K.; Johnson, G.A.

    1993-01-01

    The Alkali Metal Thermal to Electric Converter (AMTEC) system is an exceptional candidate for high performance spacecraft power systems including small systems powered by General Purpose Heat Sources (GPHS). The AMTEC converter is best described as a thermally regenerative electrochemical concentration cell. AMTEC is a static energy conversion device and can operate at efficiencies between 15% and 30%. The single tube, remote condensed, wick return minicell design has been incorporated into a radioisotope powered system model. Reported cell efficiencies used for these system design studies ranged from 15% to 25%. This efficiency is significantly higher than other static conversion systems operating at the same temperatures. Savings in mass and cost, relative to other more conventional static conversion systems, have also been shown. The minicell used for this system study has many advanced features not combined in previous designs, including wick return, remote condensing, and hot zone feedthroughs. All of these features significantly enhance the performance of the AMTEC cell. Additionally, the cell end provides enough area for adequate heat transfer from the GPHS module, eliminating the need for a ''hot shoe'', and reducing the complexity and weight of the system. This paper describes and compares small (two module) and larger (16 module) AMTEC radioisotope powered systems and describes the computer model developed to predict their performance

  1. Power system analysis of Hanlim superconducting HVDC system using real time digital simulator

    International Nuclear Information System (INIS)

    Won, Y.J.; Kim, J.G.; Kim, A.R.; Kim, G.H.; Park, M.; Yu, I.K.; Sim, K.D.; Cho, J.; Lee, S.; Jeong, K.W.; Watanabe, K.

    2011-01-01

    KEPCO has planned to construct a test site for renewable energy in Jeju power system. One kilometer length of total 8 km was designed as superconducting DC cable. We have developed a simulation model of the 8 km HVDC system using real time digital simulator. The simulation result shows that the HVDC line was not affected by wind power variation. Jeju island is located approximately 100 km south from the mainland of Korea, and had a peak load of about 553 MW in 2008. The demand increases 7.2% a year over the last 5 years. Since the wind profiles of Jeju island are more favorable than mainland of Korea, many companies have shown interest in the wind power business at the Jeju island. Moreover KEPCO has a plan for renewable energy test too whose power will be delivered by HVDC system. One kilometer length of total 8 km was designed as superconducting DC cable. Rest 7 km will be the conventional overhead line. In this paper, the authors have developed a simulation model of the power network around 8 km HVDC system using real time digital simulator (RTDS).

  2. Feed-Forward Control of Kite Power Systems

    International Nuclear Information System (INIS)

    Fechner, Uwe; Schmehl, Roland

    2014-01-01

    Kite power technology is a novel solution to harvest wind energy from altitudes that can not be reached by conventional wind turbines. The use of a lightweight but strong tether in place of an expensive tower provides an additional cost advantage, next to the higher capacity factor. This paper describes a method to estimate the wind velocity at the kite using measurement data at the kite and at the ground. Focussing on a kite power system, which is converting the traction power of a kite in a pumping mode of operation, a reel-out speed predictor is presented for use in feed-forward control of the tether reel-out speed of the winch. The results show, that the developed feedforward controller improves the force control accuracy by a factor of two compared to the previously used feedback controller. This allows to use a higher set force during the reel-out phase which in turn increases the average power output by more than 4%. Due to its straightforward implementation and low computational requirements feedforward control is considered a promising technique for the reliable and efficient operation of traction-based kite power systems

  3. Research on a Small Signal Stability Region Boundary Model of the Interconnected Power System with Large-Scale Wind Power

    Directory of Open Access Journals (Sweden)

    Wenying Liu

    2015-03-01

    Full Text Available For the interconnected power system with large-scale wind power, the problem of the small signal stability has become the bottleneck of restricting the sending-out of wind power as well as the security and stability of the whole power system. Around this issue, this paper establishes a small signal stability region boundary model of the interconnected power system with large-scale wind power based on catastrophe theory, providing a new method for analyzing the small signal stability. Firstly, we analyzed the typical characteristics and the mathematic model of the interconnected power system with wind power and pointed out that conventional methods can’t directly identify the topological properties of small signal stability region boundaries. For this problem, adopting catastrophe theory, we established a small signal stability region boundary model of the interconnected power system with large-scale wind power in two-dimensional power injection space and extended it to multiple dimensions to obtain the boundary model in multidimensional power injection space. Thirdly, we analyzed qualitatively the topological property’s changes of the small signal stability region boundary caused by large-scale wind power integration. Finally, we built simulation models by DIgSILENT/PowerFactory software and the final simulation results verified the correctness and effectiveness of the proposed model.

  4. Decay Power Calculation for Safety Analysis of Innovative Reactor Systems

    International Nuclear Information System (INIS)

    Shwageraus, E.; Fridman, E.

    2008-01-01

    In this work, we verified the decay heat calculation capabilities of BGCore computer code system developed recently at Ben-Gurion University. Decay power was calculated for a typical UO 2 fuel in Pressurized Water Reactor environment using BGCore code and using procedure prescribed by the ANS/ANSI-2005 standard. Very good agreement between the two methods was obtained. Once BGCore calculation capabilities were verified, we calculated decay power as a function of time after shutdown for various reactors with innovative fuels, for which no standard procedure is currently available. Notable differences were observed for decay power of the advanced reactors as compared with conventional UO 2 LWR. The observed differences suggest that the design of new reactors safety systems must be based on corresponding decay power curves for each individual case in order to assure the desired performance of such systems. (authors)

  5. Power system stabilizers based on distributed energy resources for damping of inter-area oscillations

    Directory of Open Access Journals (Sweden)

    Stefanov Predrag Č.

    2014-01-01

    Full Text Available This paper deals with inter-area power oscillations damping enhancement by distributed energy resources contained in typical micro grid. Main idea behind this work is to use distributed generation and distributed storage, such as battery energy storage to mimic conventional power system stabilizer, but with regulating active power output, rather than reactive power, as in standard power system stabilizer realization. The analysis of the small signal stability is established for four-machine, two-area system, with inverter based micro grids in each area. Dynamic simulation results are included in this work and they show that proposed controller provides additional damping effect to this test system.

  6. Influence of renewable sources of energy on the operation of the production capacity in electrical power systems

    International Nuclear Information System (INIS)

    Nikolova-Potseva, Sofija

    2012-01-01

    In the PhD dissertation an approach for solving the generation scheduling problem between conventional power plants in a complex power system with integrated wind power plants is presented. The system that is analyzed is composed of thermal power plants, storage hydro power plants, pumped-storage hydro power plants, additional systems to deal with pumping water of pumped-storage hydro power plants and wind power plants. The model takes into consideration thermal power plants with and without contracted energy production over the study period. The objective of the generation scheduling problem in such a hybrid system is to determine the optimal amounts of generation power of conventional power plants over the study period, so that the total production costs of thermal power plants and additional units engaged for pumping water of pumped-storage hydro power plants be minimal and be satisfied the relevant real operational constraints of the system. The problem model takes into account the following constraints: power balance equations, constraints resulting from power output limits of thermal and hydro power plants, balance equations for contracted energy for thermal power plants with contracted energy production, power output limits of wind energy system and balance equations for available volume of water of storage hydro power plants and pumped-storage hydro power plants over the study period. The proposed model for power plant optimal operation does not take into account the system configuration and network losses. The computer program is developed in Matlab, in order to verify the proposed method for solving the optimal generation scheduling of conventional power plants in complex power system with integrated wind power plants. The developed computer program has been applied to specific systems and different variants of systems with integrated wind power plants have been analyzed. Particular problem in the operation of the power system is suppressed energy towards

  7. Fundamentals of electric power engineering engineering from electromagnetics to power systems

    CERN Document Server

    Ceraolo, Massimo

    2014-01-01

    At the basis of many sectors of engineering, electrical engineering deals with electricity phenomena involved in the transfer of energy and power. Professionals requiring a refresher course in this interdisciplinary branch need look no further than Fundamentals of Electric Power Engineering, which imparts tools and trade tricks to remembering basic concepts and grasping new developments. Even established engineers must supplement their careers with an invigorated knowledge base, and this comprehensive resource helps non-electrical engineers amass power system information quickly.

  8. Electric vehicles to support large wind power penetration in future danish power systems

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte; Thøgersen, Paul

    2012-01-01

    Electric Vehicles (EVs) could play major role in the future intelligent grids to support a large penetration of renewable energy in Denmark, especially electricity production from wind turbines. The future power systems aims to phase-out big conventional fossil-fueled generators with large number...... on low voltage residential networks. Significant amount of EVs could be integrated in local distribution grids with the support of intelligent grid and smart charging strategies....

  9. Design and control strategy applying the novel highly effective magnetic flux coupling (HEMFC) scheme for a non-contact power transfer system

    International Nuclear Information System (INIS)

    Chen, W.-P.; Huang, W.-N.; Chen, P.-S.; Fan, T.-Y.; Chen, M.-P.; Teng, C.-C.

    2006-01-01

    In this paper, the novel design concept for highly effective magnetic flux coupling (HEMFC) schemes, based on enhancement of path guiding effect for leakage flux transmitting, is proposed for a non-contact power transfer system. Two implementation techniques are presented herein utilizing simple structure opinions of specific slant air gap as well as adding of metal bushing components. Both simulation and experimental results demonstrate that the improvement of magnetic coupling ratio and overall system efficiency are achieved by applying the two HEMFC schemes as the power transmitting devices

  10. PERFORMANCE OF MASHONA COWS REARED ON NATURAL RANGELANDS WITH NON-CONVENTIONAL PROTEIN SUPPLEMENTATION IN THE DRY SEASON, ZIMBABWE

    Directory of Open Access Journals (Sweden)

    Jacob Gusha

    2015-12-01

    Full Text Available Performance of animals in smallholder farming systems is hindered by feed availability and feed costs that make up 60-70% of total variable cost in a farming system. The use of non-conventional feedstuffs is an alternative which can be adopted to minimize feeding costs. The study was conducted to evaluate performance of animals fed with supplements formulated on-farm in comparison with a commercial prepared supplement. Thirty Mashona cows were grouped according to age and subjected to five treatments, given twice a week from the 1st of September until 31st December for three subsequent years. The five treatment diets, beef survival meal (BSM, urea treated maize stover (UTS, Leucaena leucocephala meal (LLM, mixed forage meal (MFM and natural pastures (NP were randomly assigned to cows in a complete randomised design (CRD. Average weight gains were determined. Performance in the first year was not significantly different across treatments. In the subsequent years, performance remained low in the NP. Average weight gains increased in the second and third years and was significantly different across treatments (P<0.05. Performance of animals supplemented with non-conventional feed was comparable to those offered commercial BFM; hence LLM and UTS can be used as alternative protein supplements especially in resource-constrained farming systems. Â

  11. Probabilistic life-cycle cost analysis for renewable and non-renewable power plants

    International Nuclear Information System (INIS)

    Cartelle Barros, Juan José; Lara Coira, Manuel; Cruz López, María Pilar de la; Caño Gochi, Alfredo del

    2016-01-01

    Two probabilistic models are presented to assess the costs of power plants. One of them uses requirement trees, value functions and the analytic hierarchy process. It is also based on Monte Carlo simulation. The second one is a mathematical model for calculating the levelised cost of electricity (LCOE) based on discounted cash flow techniques, and combined with Monte Carlo simulation. The results obtained with both models are compared and discussed. On the one hand, the LCOE model provides the most reliable results. These results reinforce the idea that conventional or coal, lignite, oil, natural gas and nuclear power plants are still the most competitive options, with the LCOE falling in a range of around 25 to 200 €/MWh and mean values approaching 70 €/MWh. Generally, renewable power plants obtained the worst results, with a LCOE varying from around 30 to more than 450 €/MWh. Nevertheless, this study demonstrates that renewable alternatives can compete with their conventional counterparts under certain conditions. - Highlights: • Two probabilistic models are presented to assess the costs of power plants. • Conventional power plants are still the most competitive options. • Renewable energies can compete with their conventional counterparts under certain conditions. • The model aids the decision making process in the energy policy field.

  12. Non-conventional fuel tax credit

    International Nuclear Information System (INIS)

    Soeoet, P.M.

    1988-01-01

    Coal-seam methane, along with certain other non-conventional fuels, is eligible for a tax credit. This production tax credit allowed coal-seam methane producers to receive $0.7526 per million Btu of gas sold during 1986. In 1987, this credit rose to $0.78 per million Btu. The tax credit is a very significant element of the economic analysis of current coal-seam methane projects. In today's spot market, gas prices are around $1.50 per million Btu. Allowing for costs of production, the gas producer will net more income from the tax credit than from the sale of the gas. The Crude Oil Windfall Profit Tax Act of 1980 is the source of this tax credit. There were some minor changes made by subsequent legislation, but most of the tax credit has remained intact. Wells must be drilled by 1990 to qualify for the tax credit but the production from such wells is eligible for the tax credit until 2001. Projections have been made, showing that the tax credit should increase to $0.91 per million Btu for production in 1990 and $1.34 per million Btu in 2000. Variables which may decrease the tax credit from these projections are dramatically lower oil prices or general economic price deflation

  13. The ITER poloidal field system: control and power supplies

    International Nuclear Information System (INIS)

    Mondino, P.L.; Benfatto, I.; Gribov, Y.; Matsukawa, M.; Odajima, K.; Portone, A.; Roshal, A.; Bareyt, B.; Bertolini, E.; Bottereau, J.M.; Huart, M.; Maschio, A.; Bulgakov, S.; Kuchinski, V.

    1995-01-01

    The paper reports the preliminary scenario of the ITER Poloidal Field (PF) system operation, the method used to evaluate the installed power, the basic structure of the circuits and finally the concepts of the preliminary design of control and power supply. The superconducting coils are energized from the HV Grid with conventional AC/DC converters. R and D is required for circuit breakers, make switches and resistors, the basic components of both the switching networks and the discharge circuits. (orig.)

  14. Neuro-Fuzzy Computational Technique to Control Load Frequency in Hydro-Thermal Interconnected Power System

    Science.gov (United States)

    Prakash, S.; Sinha, S. K.

    2015-09-01

    In this research work, two areas hydro-thermal power system connected through tie-lines is considered. The perturbation of frequencies at the areas and resulting tie line power flows arise due to unpredictable load variations that cause mismatch between the generated and demanded powers. Due to rising and falling power demand, the real and reactive power balance is harmed; hence frequency and voltage get deviated from nominal value. This necessitates designing of an accurate and fast controller to maintain the system parameters at nominal value. The main purpose of system generation control is to balance the system generation against the load and losses so that the desired frequency and power interchange between neighboring systems are maintained. The intelligent controllers like fuzzy logic, artificial neural network (ANN) and hybrid fuzzy neural network approaches are used for automatic generation control for the two area interconnected power systems. Area 1 consists of thermal reheat power plant whereas area 2 consists of hydro power plant with electric governor. Performance evaluation is carried out by using intelligent (ANFIS, ANN and fuzzy) control and conventional PI and PID control approaches. To enhance the performance of controller sliding surface i.e. variable structure control is included. The model of interconnected power system has been developed with all five types of said controllers and simulated using MATLAB/SIMULINK package. The performance of the intelligent controllers has been compared with the conventional PI and PID controllers for the interconnected power system. A comparison of ANFIS, ANN, Fuzzy and PI, PID based approaches shows the superiority of proposed ANFIS over ANN, fuzzy and PI, PID. Thus the hybrid fuzzy neural network controller has better dynamic response i.e., quick in operation, reduced error magnitude and minimized frequency transients.

  15. Power system analysis of Hanlim superconducting HVDC system using real time digital simulator

    Science.gov (United States)

    Won, Y. J.; Kim, J. G.; Kim, A. R.; Kim, G. H.; Park, M.; Yu, I. K.; Sim, K. D.; Cho, J.; Lee, S.; Jeong, K. W.; Watanabe, K.

    2011-11-01

    Jeju island is located approximately 100 km south from the mainland of Korea, and had a peak load of about 553 MW in 2008. The demand increases 7.2% a year over the last 5 years. Since the wind profiles of Jeju island are more favorable than mainland of Korea, many companies have shown interest in the wind power business at the Jeju island. Moreover KEPCO has a plan for renewable energy test too whose power will be delivered by HVDC system. One kilometer length of total 8 km was designed as superconducting DC cable. Rest 7 km will be the conventional overhead line. In this paper, the authors have developed a simulation model of the power network around 8 km HVDC system using real time digital simulator (RTDS).

  16. Selectivity of power system protections at power swings in power system

    Directory of Open Access Journals (Sweden)

    Jan Machowski

    2012-12-01

    Full Text Available The paper discusses out-of-step protection systems such as: generator pole slip protections, out of step tripping protections, distance protections of step-up transformer, distance protections of transmission lines and transformers, power swing blocking, and special out-of-step protection. It is shown that all these protections make up a protection system, to which a setting concept uniform for the entire power system has to be applied. If a power system is inappropriately equipped with these protections, or their settings are inappropriate, they may operate unselectively, thus contributing to the development of power system blackouts. In the paper the concepts for a real power system are given for the two stages: target stage fully compliant with selectivity criteria, and transitional stage between the current and target stages.

  17. The long term plan for the integration of nuclear power plants into the Turkish Electrical Power System

    International Nuclear Information System (INIS)

    Kutukcuoglu, A.

    1974-03-01

    The report covers in detail the study of the expansion of the Turkish Electric Power System for the period 1980-1987. Load forecast is done by sectors and regions and inter-regions power balances gave the basis for the high voltage network configurations. Expansion alternatives are defined giving priority to hydroelectric projects, to local resources and nuclear power plants concurrently with conventional plants (lignite and oil). Several reactor strategies are analysed with LWR, HWR, FBR and HTGR power plants. Present worth value method is used for comparison of alternatives and sensitivity analysis is done for those ranked in the first places. Load flow, transient stability and frequency deviation studies of the power system are studied carefully by means of A.C. calculator and digital computer codes in order to see the influence of the introduction of large-sized power plants (600-750MW(e)) and their location in the power system. A 600MW(e) nuclear plant in 1983 and a second one of 750MW(e) in 1987 should, it is found, be commissioned into the system. The economic optimization was done with two computer programmes developed by KFA (Juelich): IACO for fuelling nuclear plant and RESTRAPO for power system with high hydroelectric component. The report is bound in three volumes: Volume I: Summary and Conclusions; Volume II: System Planning; Volume III: Electrical Survey

  18. Economics of wind power and comparisons with conventional thermal plant

    International Nuclear Information System (INIS)

    Milborrow, D.

    1994-01-01

    Commercial deployment of renewables in the UK depends on their prices converging with those of the conventional sources of generation. Price comparisons, however, are distorted by institutional factors such as the very short contract periods for premium prices under the first two rounds of the Non-Fossil Fuel Obligation (NFFO). Prices are therefore put on a common basis and the prospects for wind energy up to the year 2000 are examined. (author)

  19. Design of Conventional Submarines with Advanced Air Independent Propulsion Systems and Determination of Corresponding Theater-Level Impacts

    Science.gov (United States)

    2010-01-01

    rescue vehicle e: Error term ft: Feet HDW: Howaldtswerke- Deutsche Werft GmbH PEMFC : Proton exchange membrane fuel cells IR: Indiscretion rate/ratio...engines &Rankine cycle power plants &Closed cycle engines A PEMFC AIP system is fitted in the 212 class of submarines that German shipbuilders How...bines a conventional system consisting of a diesel engine and a lead acid battery, with the PEMFC AIP system used for slow, silent cruising. The AIP

  20. An Innovative System for the Efficient and Effective Treatment of Non-Traditional Waters for Reuse in Thermoelectric Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    John Rodgers; James Castle

    2008-08-31

    This study assessed opportunities for improving water quality associated with coal-fired power generation including the use of non-traditional waters for cooling, innovative technology for recovering and reusing water within power plants, novel approaches for the removal of trace inorganic compounds from ash pond effluents, and novel approaches for removing biocides from cooling tower blowdown. This research evaluated specifically designed pilot-scale constructed wetland systems for treatment of targeted constituents in non-traditional waters for reuse in thermoelectric power generation and other purposes. The overall objective of this project was to decrease targeted constituents in non-traditional waters to achieve reuse criteria or discharge limitations established by the National Pollutant Discharge Elimination System (NPDES) and Clean Water Act (CWA). The six original project objectives were completed, and results are presented in this final technical report. These objectives included identification of targeted constituents for treatment in four non-traditional water sources, determination of reuse or discharge criteria for treatment, design of constructed wetland treatment systems for these non-traditional waters, and measurement of treatment of targeted constituents in non-traditional waters, as well as determination of the suitability of the treated non-traditional waters for reuse or discharge to receiving aquatic systems. The four non-traditional waters used to accomplish these objectives were ash basin water, cooling water, flue gas desulfurization (FGD) water, and produced water. The contaminants of concern identified in ash basin waters were arsenic, chromium, copper, mercury, selenium, and zinc. Contaminants of concern in cooling waters included free oxidants (chlorine, bromine, and peroxides), copper, lead, zinc, pH, and total dissolved solids. FGD waters contained contaminants of concern including arsenic, boron, chlorides, selenium, mercury

  1. Performance limits of ion extraction systems with non-circular apertures

    Energy Technology Data Exchange (ETDEWEB)

    Shagayda, A., E-mail: shagayda@gmail.com; Madeev, S. [Keldysh Research Centre, Onezhskaya, 8, 125438 Moscow (Russian Federation)

    2016-04-15

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  2. Performance limits of ion extraction systems with non-circular apertures.

    Science.gov (United States)

    Shagayda, A; Madeev, S

    2016-04-01

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  3. Performance limits of ion extraction systems with non-circular apertures

    Science.gov (United States)

    Shagayda, A.; Madeev, S.

    2016-04-01

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  4. Performance limits of ion extraction systems with non-circular apertures

    International Nuclear Information System (INIS)

    Shagayda, A.; Madeev, S.

    2016-01-01

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  5. Energy-Efficient Power Allocation for MIMO-SVD Systems

    KAUST Repository

    Sboui, Lokman; Rezki, Zouheir; Alouini, Mohamed-Slim

    2017-01-01

    In this paper, we address the problem of energyefficient power allocation in MIMO systems. In fact, the widely adopted water-filling power allocation does not ensure the maximization of the energy efficiency (EE). Since the EE maximization is a non

  6. Fusion reactor cost reductions by employing non-nuclear grade components

    International Nuclear Information System (INIS)

    Bourque, R.F.; Maya, I.; Schultz, K.R.; Sonn, D.L.; Wise, R.K.

    1987-09-01

    The Cascade inertial confinement fusion reactor fits the requirements of low radioactive inventories and inherent safety and is therefore a candidate for non-nuclear construction throughout. This reactor consists of a rotating blanket of ceramic granules that absorb the energy from D-T target explosions occurring along the rotational axis. Laser energy is beamed in axially from both ends. Two cost estimates were made for an 815 MWe Cascade power plant. One was based on an ''all conventional'' plant, which is constructed and costed using well-established, conventional fossil power plant methods. The second was a ''nuclear plus conventional'' design, constructed and costed using a combination of fossil and fission reactor plant methods and standards that would be typical of advanced fission reactors. The total capital requirements for the ''all conventional'' construction plant were estimated in 1985 dollars at $1490 M, including indirect costs. Similarly, the ''nuclear plus conventional'' construction plant was estimated at $1940 M. The savings of $450 M (23%) represents strictly the difference between Cascade ICF power plants designed and constructed to nuclear safety-related requirements versus all non-nuclear. This example clearly shows that, if fusion plants can take advantage of low activation materials and inherent safety features to eliminate the need for nuclear-related expenses, then such plants may have economic advantages over nuclear-grade systems. 13 refs., 1 fig., 5 tabs

  7. A new converter for improving efficiency of multi-actuators fluid power system

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Yong; Shang, JianZhong; Yang, JunHong; Wang Zhuo [National University of Defense Technology, Changsha (China)

    2016-05-15

    This paper is concerned with the application of energy efficient fluid power in mobile robots system and proposes a new fluid power converter system which is analogous to a boost converter in power electronics. The fluid power converter system is based on the principle of pulse-width modulation. The fluid power converter has an effect akin to an electrical switched inductance transformer, wherein the output pressure or flow rate can be stepped up or down. Using an inductive reactance device (an inertia mass-block), the output flow and pressure can be varied to meet the load by a means that does not rely on dissipation of power (the resistance control). The simulation model based on the mathematics models of the components is built to analyse the performance of the fluid power converter. It is clearly shown that the fluid power converter has higher energy efficiency than conventional resistance control manners.

  8. Advanced Techniques for Reservoir Simulation and Modeling of Non-Conventional Wells

    Energy Technology Data Exchange (ETDEWEB)

    Durlofsky, Louis J.

    2000-08-28

    This project targets the development of (1) advanced reservoir simulation techniques for modeling non-conventional wells; (2) improved techniques for computing well productivity (for use in reservoir engineering calculations) and well index (for use in simulation models), including the effects of wellbore flow; and (3) accurate approaches to account for heterogeneity in the near-well region.

  9. Oil shale, shale oil, shale gas and non-conventional hydrocarbons

    Directory of Open Access Journals (Sweden)

    Clerici A.

    2015-01-01

    Full Text Available In recent years there has been a world “revolution” in the field of unconventional hydrocarbon reserves, which goes by the name of “shale gas”, gas contained inside clay sediments micropores. Shale gas finds particular development in the United States, which are now independent of imports and see a price reduction to less than one third of that in Europe. With the high oil prices, in addition to the non-conventional gas also “oil shales” (fine-grained sedimentary rocks that contain a large amount of organic material to be used both to be directly burned or to extract liquid fuels which go under the name of shale oil, extra heavy oils and bitumen are becoming an industrial reality. Both unconventional gas and oil reserves far exceed in the world the conventional oil and gas reserves, subverting the theory of fossil fuels scarcity. Values and location of these new fossil reserves in different countries and their production by comparison with conventional resources are presented. In view of the clear advantages of unconventional fossil resources, the potential environmental risks associated with their extraction and processing are also highlighted.

  10. Research on a New Control Scheme of Photovoltaic Grid Power Generation System

    Directory of Open Access Journals (Sweden)

    Dong-Hui Li

    2014-01-01

    Full Text Available A new type of photovoltaic grid power generation system control scheme to solve the problems of the conventional photovoltaic grid power generation systems is presented. To aim at the oscillation and misjudgment of traditional perturbation observation method, an improved perturbation observation method comparing to the next moment power is proposed, combining with BOOST step-up circuit to realize the maximum power tracking. To counter the harmonic pollution problem in photovoltaic grid power generation system, the deadbeat control scheme in fundamental wave synchronous frequency rotating coordinate system of power grid is presented. A parameter optimization scheme based on positive feedback of active frequency shift island detection to solve the problems like the nondetection zone due to the import of disturbance in traditional island detection method is proposed. Finally, the results in simulation environment by MATLAB/Simulink simulation and experiment environment verify the validity and superiority of the proposed scheme.

  11. Low-power non-volatile spintronic memory: STT-RAM and beyond

    International Nuclear Information System (INIS)

    Wang, K L; Alzate, J G; Khalili Amiri, P

    2013-01-01

    The quest for novel low-dissipation devices is one of the most critical for the future of semiconductor technology and nano-systems. The development of a low-power, universal memory will enable a new paradigm of non-volatile computation. Here we consider STT-RAM as one of the emerging candidates for low-power non-volatile memory. We show different configurations for STT memory and demonstrate strategies to optimize key performance parameters such as switching current and energy. The energy and scaling limits of STT-RAM are discussed, leading us to argue that alternative writing mechanisms may be required to achieve ultralow power dissipation, a necessary condition for direct integration with CMOS at the gate level for non-volatile logic purposes. As an example, we discuss the use of the giant spin Hall effect as a possible alternative to induce magnetization reversal in magnetic tunnel junctions using pure spin currents. Further, we concentrate on magnetoelectric effects, where electric fields are used instead of spin-polarized currents to manipulate the nanomagnets, as another candidate solution to address the challenges of energy efficiency and density. The possibility of an electric-field-controlled magnetoelectric RAM as a promising candidate for ultralow-power non-volatile memory is discussed in the light of experimental data demonstrating voltage-induced switching of the magnetization and reorientation of the magnetic easy axis by electric fields in nanomagnets. (paper)

  12. Current developments in mechanized non-destructive testing in nuclear power plants

    International Nuclear Information System (INIS)

    Zeilinger, R.

    2008-01-01

    Nuclear power plants require frequent in-service activities to be carried out conscientiously in areas potentially hazardous to human operators (because of the associated radiation exposure), such as non-destructive testing of pressurized components of the steam system. Locations to be inspected in this way include the reactor pressure vessel, core internals, steam generators, pressurizers, and pipes. The codes to be used as a basis of these inspections demand high absolute positioning and repeating accuracy. These requirements can be met by mechanized test procedures. Accordingly, many new applications of, mostly mobile, robots have been developed over the past few years. The innovative control and sensor systems for stationary and mobile robots now on the market offer a potential for economic application in a large number of new areas in inspection, maintenance and service in nuclear power plants. More progress in this area is expected for the near future. Areva NP founded the new NDT Center, NETEC (Non-destructive Examination Technical Center), as a global technical center for non-destructive materials testing. NETEC is to advance research and development of all basic NDT technologies, robotics included. For many years, intelligeNDT has offered solutions and products for a variety of inspection and testing purposes and locations in nuclear power plants and is involved in continuous further development of the experience collected in nuclear power plants on the spot. (orig.)

  13. Isolated Power Generation System Using Permanent Magnet Synchronous Generator with Improved Power Quality

    Science.gov (United States)

    Arya, Sabha Raj; Patel, Ashish; Giri, Ashutosh

    2018-03-01

    This paper deals wind energy based power generation system using Permanent Magnet Synchronous Generator (PMSG). It is controlled using advanced enhanced phase-lock loop for power quality features using distribution static compensator to eliminate the harmonics and to provide KVAR compensation as well as load balancing. It also manages rated potential at the point of common interface under linear and non-linear loads. In order to have better efficiency and reliable operation of PMSG driven by wind turbine, it is necessary to analyze the governing equation of wind based turbine and PMSG under fixed and variable wind speed. For handling power quality problems, power electronics based shunt connected custom power device is used in three wire system. The simulations in MATLAB/Simulink environment have been carried out in order to demonstrate this model and control approach used for the power quality enhancement. The performance results show the adequate performance of PMSG based power generation system and control algorithm.

  14. Guidelines for the verification and validation of expert system software and conventional software. Volume 7, User's manual: Final report

    International Nuclear Information System (INIS)

    Miller, L.A.; Hayes, J.E.; Mirsky, S.M.

    1995-05-01

    Reliable software is required for nuclear power industry applications. Verification and validation techniques applied during the software development process can help eliminate errors that could inhibit the proper operation of digital systems and cause availability and safety problems. Most of the techniques described in this report are valid for conventional software systems as well as for expert systems. The project resulted in a set of 16 V ampersand V guideline packages and 11 sets of procedures based on the class, development phase, and system component being tested. These guideline packages and procedures help a utility define the level of V ampersand V, which involves evaluating the complexity and type of software component along with the consequences of failure. In all, the project identified 153 V ampersand V techniques for conventional software systems and demonstrated their application to all aspects of expert systems except for the knowledge base, which requires specially developed tools. Each of these conventional techniques covers anywhere from 2-52 total types of conventional software defects, and each defect is covered by 21-50 V ampersand V techniques. The project also identified automated tools to Support V ampersand V activities

  15. Integrated information system for analysis of nuclear power plants

    International Nuclear Information System (INIS)

    Galperin, A.

    1994-01-01

    Performing complicated engineering analyses of a nuclear power plant requires storage and manipulation of a large amount of information, both data and knowledge. This information is characterized by its multidisciplinary nature, complexity, and diversity. The problems caused by inefficient and lengthy manual operations involving the data flow management within the frame-work of the safety-related analysis of a power plant can be solved by applying the computer aided engineering principles. These principles are the basis of the design of an integrated information storage system (IRIS). The basic idea is to create a computerized environment, which includes both database and functional capabilities. Consideration and analysis of the data types and required data manipulation capabilities as well as operational requirements, resulted in the choice of an object-oriented data-base management system (OODBMS) as a development platform for solving the software engineering problems. Several advantages of OODBMSs over conventional relations database systems were found of crucial importance, especially providing the necessary flexibility for different data types and extensibility potential. A detailed design of a data model is produced for the plant technical data and for the storage of analysis results. The overall system architecture was designed to assure the feasibility of integrating database capabilities with procedures and functions written in conventional algorithmic programming languages

  16. Appliance based control for Home Power Management Systems

    International Nuclear Information System (INIS)

    Özkan, Hanife Apaydın

    2016-01-01

    This study scrutinizes energy-friendly smart home appliances (hereafter ‘smart appliances’), control of these appliances and their effects on the efficient use of energy. To accomplish this, smart appliances and their operation principles are introduced and their energy savings compared to conventional appliances are analyzed using precise measurements. Then, a real-time Appliance-based Home Power Management System (Ab-HPMS) which manages power consumption of smart appliances and that of the house as a whole is proposed. For Ab-HPMS, an appliance control algorithm, called Appliance-based Rolling Wave Planning (Ab-RWP), is developed with the aim of reducing electricity cost and improving energy efficiency while maintaining user comfort. Ab-RWP algorithm interacts with appliances in a priority order based on user comfort which is determined by utilizing their smart operational characteristics. Operations of smart appliances and their integrations with Ab-HPMS are modeled with Petri nets to verify that they meet the requirements expressed in the specifications. Simulation results demonstrate that proposed Ab-HPMS provides improvements in terms of the energy consumption reduction of about 5%–16%, cost reduction of about 10%–24% and peak reduction at high demand period of about 38%–53% compared to conventional appliances usage. - Highlights: • The effects of smart home appliances on energy saving are investigated. • Petri nets models of smart appliances are developed to simulate their operations in smart home. • A real-time appliance-based home power management system (Ab-HPMS) is proposed. • Power density function is evaluated to interrupt the operation of smart washing machine.

  17. Decay Power Calculation for Safety Analysis of Innovative Reactor Systems

    Energy Technology Data Exchange (ETDEWEB)

    Shwageraus, E.; Fridman, E. [Department of Nuclear Engineering, Ben-Gurion University of the Negev Beer-Sheva 84105 (Israel)

    2008-07-01

    In this work, we verified the decay heat calculation capabilities of BGCore computer code system developed recently at Ben-Gurion University. Decay power was calculated for a typical UO{sub 2} fuel in Pressurized Water Reactor environment using BGCore code and using procedure prescribed by the ANS/ANSI-2005 standard. Very good agreement between the two methods was obtained. Once BGCore calculation capabilities were verified, we calculated decay power as a function of time after shutdown for various reactors with innovative fuels, for which no standard procedure is currently available. Notable differences were observed for decay power of the advanced reactors as compared with conventional UO{sub 2} LWR. The observed differences suggest that the design of new reactors safety systems must be based on corresponding decay power curves for each individual case in order to assure the desired performance of such systems. (authors)

  18. Operating modes and practical power flow analysis of bidirectional isolated power interface for distributed power systems

    International Nuclear Information System (INIS)

    Wen, Huiqing; Su, Bin

    2016-01-01

    Highlights: • Four operating modes of Dual-Phase-Shift control for Dual Active Bridge converter are presented. • Effects of “minor parameters” such as the deadtime and power device voltage drops are analyzed. • Accurate power flow models with Dual-Phase-Shift control are developed and verified with experimental results. • Optimal operating mode is determined with respect to the efficiency improvement. • Measured efficiency of the Dual Active Bridge converter is improved up to 14%. - Abstract: Due to the intermittent nature of the renewable energy sources including photovoltaic and wind energy, the energy storage systems are essential to stabilize dc bus voltage. Considering the discharge depth of super-capacitors and energy-storage batteries, the bidirectional isolated power interface will operate for a wide range of voltage and power. This study focuses on in-depth analysis of the dual-active-bridge dc–dc converter that is controlled by the dual-phase-shift scheme to improve the conversion efficiency in distributed power system. The power flow of each operating mode with dual-phase-shift control is characterized based on a detailed analysis of the effects of “minor parameters”, including the deadtime and power device voltage drops. The complete output power plane of the dual-active-bridge converter with dual-phase-shift control is obtained and compared with experimental results. The optimal operating mode is determined according to the practical output power range and the power flow characteristics. Experimental evaluation shows the effectiveness of the proposed power flow model with dual-phase-shift control and significant efficiency improvement using the optimal mode of dual-phase-shift compared with the conventional phase shift control.

  19. International practice patterns and factors associated with non-conventional hemodialysis utilization

    Directory of Open Access Journals (Sweden)

    Allen Nathan

    2011-12-01

    Full Text Available Abstract Background The purpose of our study was to determine characteristics that influence the utilization of non-conventional hemodialysis (NCHD therapies and its subtypes (nocturnal (NHD, short daily (SDHD, long conventional (LCHD and conventional hemodialysis (CHD as well as provider attitudes regarding the evidence for NCHD use. Methods An international cohort of subscribers of a nephrology education website http://www.nephrologynow.com was invited to participate in an online survey. Non-conventional hemodialysis was defined as any forms of hemodialysis delivered > 3 treatments per week and/or > 4 hours per session. NHD and SDHD included both home and in-centre. Respondents were categorized as CHD if their centre only offered conventional thrice weekly hemodialysis. Variables associated with NCHD and its subtypes were determined using multivariate logistic regression analysis. The survey assessed multiple domains regarding NCHD including reasons for initiating and discontinuing, for not offering and attitudes regarding evidence. Results 544 surveys were completed leading to a 15.6% response rate. The final cohort was limited to 311 physicians. Dialysis modalities utilized among the respondents were as follows: NCHD194 (62.4%, NHD 83 (26.7%, SDHD 107 (34.4%, LCHD 81 (26% and CHD 117 (37.6%. The geographic regions of participants were as follows: 11.9% Canada, 26.7% USA, 21.5% Europe, 6.1% Australia/New Zealand, 10% Africa/Middle East, 10.9% Asia and 12.9% South America. Variables associated with NCHD utilization included NCHD training (OR 2.47 CI 1.25-4.16, government physician reimbursement (OR 2.66, CI 1.11-6.40, practicing at an academic centre (OR 2.28 CI 1.25-4.16, higher national health care expenditure and number of ESRD patients per centre. Hemodialysis providers with patients on NCHD were significantly more likely to agree with the statements that NCHD improves quality of life, improves nutritional status, reduces EPO requirements

  20. Development of Highly Survivable Power and Communication System for NPP Instruments under Severe Accident

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seung J.; Gu, Beom W.; Nguyen, Duy T.; Choi, Bo H.; Rim, Chun T. [KAIST, Daejeon (Korea, Republic of); Lee, So I. [KHNP CRI, Daejeon (Korea, Republic of)

    2014-10-15

    According to the detail report from the Fukushima nuclear accident, the failure of conventional instruments is mainly due to the following reasons. 1) Insufficient backup battery capacity after the station black out (SBO) 2) The malfunction or damage of instruments due to the extremely harsh ambient condition after the severe accident 3) The cut-off of power and communication cable due to the physical shocks of hydrogen explosion after the severe accident Since the current equipment qualification (EQ) for the NPP instruments is based on the design basis accident such as loss of coolant accident (LOCA), conventional instruments, which are examined under EQ condition, cannot guarantee their normal operation during the severe accident. A 7m-long-distance wireless power transfer and a radio frequency (RF) communication were introduced with conventional wired system to increase a redundancy. A heat isolation box and a harness are adopted to provide a protection from the expected physical shocks such as missiles and drastic increase of ambient temperature and pressure. A detail design principle of the highly survivable power and communication system, which has 4 sub-systems of a DCRS wireless power transfer, a Zigbee wireless communication, a GFRP harness, and a passive type router with a fly back regulator, has been presented in this paper. Each sub-system has been designed to have a robust operation characteristic regardless of the estimated physical shocks after the severe accident.

  1. Development of Highly Survivable Power and Communication System for NPP Instruments under Severe Accident

    International Nuclear Information System (INIS)

    Yoo, Seung J.; Gu, Beom W.; Nguyen, Duy T.; Choi, Bo H.; Rim, Chun T.; Lee, So I.

    2014-01-01

    According to the detail report from the Fukushima nuclear accident, the failure of conventional instruments is mainly due to the following reasons. 1) Insufficient backup battery capacity after the station black out (SBO) 2) The malfunction or damage of instruments due to the extremely harsh ambient condition after the severe accident 3) The cut-off of power and communication cable due to the physical shocks of hydrogen explosion after the severe accident Since the current equipment qualification (EQ) for the NPP instruments is based on the design basis accident such as loss of coolant accident (LOCA), conventional instruments, which are examined under EQ condition, cannot guarantee their normal operation during the severe accident. A 7m-long-distance wireless power transfer and a radio frequency (RF) communication were introduced with conventional wired system to increase a redundancy. A heat isolation box and a harness are adopted to provide a protection from the expected physical shocks such as missiles and drastic increase of ambient temperature and pressure. A detail design principle of the highly survivable power and communication system, which has 4 sub-systems of a DCRS wireless power transfer, a Zigbee wireless communication, a GFRP harness, and a passive type router with a fly back regulator, has been presented in this paper. Each sub-system has been designed to have a robust operation characteristic regardless of the estimated physical shocks after the severe accident

  2. Joint terminals and relay optimization for two-way power line information exchange systems with QoS constraints

    Science.gov (United States)

    Wu, Xiaolin; Rong, Yue

    2015-12-01

    The quality-of-service (QoS) criteria (measured in terms of the minimum capacity requirement in this paper) are very important to practical indoor power line communication (PLC) applications as they greatly affect the user experience. With a two-way multicarrier relay configuration, in this paper we investigate the joint terminals and relay power optimization for the indoor broadband PLC environment, where the relay node works in the amplify-and-forward (AF) mode. As the QoS-constrained power allocation problem is highly non-convex, the globally optimal solution is computationally intractable to obtain. To overcome this challenge, we propose an alternating optimization (AO) method to decompose this problem into three convex/quasi-convex sub-problems. Simulation results demonstrate the fast convergence of the proposed algorithm under practical PLC channel conditions. Compared with the conventional bidirectional direct transmission (BDT) system, the relay-assisted two-way information exchange (R2WX) scheme can meet the same QoS requirement with less total power consumption.

  3. A survey on the contributions of power electronics to smart grid systems

    OpenAIRE

    COLAK ILHAMI; KABALCI Ersan; FULLI Gianluca; LAZAROU STAVROS

    2014-01-01

    The smart grid (SG) as a research area is advancing dealing with a wider range of topics such as power systems, energy generation and telecommunication. The conventional utility grid used to operate in a passive mode absorbing energy from the substations and delivering it to the customers. This approach is well developed but the needs of the state-of-the-art technology require a bidirectional flow of power and data. Nevertheless, smart grid systems provide more flexible, reliable, sustainable...

  4. Object-Oriented Economic Power Dispatch of Electrical Power System with minimum pollution using a Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    T. Bouktir

    2005-06-01

    Full Text Available This paper presents solution of optimal power flow (OPF problem of electrical power system via a genetic algorithm of real type. The objective is to minimize the total fuel cost of generation and environmental pollution caused by fossil based thermal generating units and also maintain an acceptable system performance in terms of limits on generator real and reactive power outputs, bus voltages, shunt capacitors/reactors, transformers tap-setting and power flow of transmission lines. CPU times can be reduced by decomposing the optimization constraints to active constraints that affect directly the cost function manipulated directly the GA, and passive constraints such as generator bus voltages and transformer tap setting maintained in their soft limits using a conventional constraint load flow. The algorithm was developed in an Object Oriented fashion, in the C++ programming language. This option satisfies the requirements of flexibility, extensibility, maintainability and data integrity. The economic power dispatch is applied to IEEE 30-bus model system (6-generator, 41-line and 20-load. The numerical results have demonstrate the effectiveness of the stochastic search algorithms because its can provide accurate dispatch solutions with reasonable time. Further analyses indicate that this method is effective for large-scale power systems.

  5. NASA's Radioisotope Power Systems Program Overview - A Focus on RPS Users

    Science.gov (United States)

    Hamley, John A.; McCallum, Peter W.; Sandifer, Carl E., II; Sutliff, Thomas J.; Zakrajsek, June F.

    2016-01-01

    The goal of NASA's Radioisotope Power Systems (RPS) Program is to make RPS ready and available to support the exploration of the solar system in environments where the use of conventional solar or chemical power generation is impractical or impossible to meet potential future mission needs. To meet this goal, the RPS Program manages investments in RPS technologies and RPS system development, working closely with the Department of Energy. This paper provides an overview of the RPS Program content and status, its collaborations with potential RPS users, and the approach employed to maintain the readiness of RPS to support future NASA mission concepts.

  6. Phase synchronized quasiperiodicity in power electronic inverter systems

    DEFF Research Database (Denmark)

    Zhusubaliyev, Zhanybai T.; Mosekilde, Erik; Andriyanov, Alexey I.

    2014-01-01

    The development of switch-mode operated power electronic converter systems has provided a broad range of new effective approaches to the conversion of electric power. In this paper we describe the transitions from regular periodic operation to quasiperiodicity and high-periodic resonance behavior...... findings are verified through comparison with an experimental inverter system. The results shed light on the transitions to quasiperiodicity and to various forms of three-frequency dynamics in non-smooth systems....

  7. Adding Flavor to Beverages with Non-Conventional Yeasts

    Directory of Open Access Journals (Sweden)

    Davide Ravasio

    2018-02-01

    Full Text Available Fungi produce a variety of volatile organic compounds (VOCs during their primary and secondary metabolism. In the beverage industry, these volatiles contribute to the the flavor and aroma profile of the final products. We evaluated the fermentation ability and aroma profiles of non-conventional yeasts that have been associated with various food sources. A total of 60 strains were analyzed with regard to their fermentation and flavor profile. Species belonging to the genera Candida, Pichia and Wickerhamomyces separated best from lager yeast strains according to a principal component analysis taking alcohol and ester production into account. The speed of fermentation and sugar utilization were analysed for these strains. Volatile aroma-compound formation was assayed via gas chromatography. Several strains produced substantially higher amounts of aroma alcohols and esters compared to the lager yeast strain Weihenstephan 34/70. Consequently, co-fermentation of this lager yeast strain with a Wickerhamomyces anomalus strain generated an increased fruity-flavour profile. This demonstrates that mixed fermentations utilizing non-Saccharomyces cerevisiae biodiversity can enhance the flavour profiles of fermented beverages.

  8. Space nuclear power systems for extraterrestrial basing

    International Nuclear Information System (INIS)

    Lance, J.R.; Chi, J.W.H.

    1989-01-01

    Previous studies of nuclear and non-nuclear power systems for lunar bases are compared with recent studies by others. Power levels from tens of kW e for early base operation up to 2000 kW e for a self-sustaining base with a Closed Environment Life Support System (CELSS) are considered. Permanent lunar or Martian bases will require the use of multiple nuclear units connected to loads with a power transmission and distribution system analogous to earth-based electric utility systems. A methodology used for such systems is applied to the lunar base system to examine the effects of adding 100 kW e SP-100 class and/or larger nuclear units when a reliability criterion is imposed. The results show that resource and logistic burdens can be reduced by using 1000 kW e units early in the base growth scenario without compromising system reliability. Therefore, both technologies being developed in two current programs (SP-100 and NERVA Derivative Reactor (NDR) technology for space power) can be used effectively for extraterrestrial base power systems. Recent developments in NDR design that result in major reductions in reactor mass are also described. (author)

  9. An energy management system for off-grid power systems

    Energy Technology Data Exchange (ETDEWEB)

    Zelazo, Daniel [Universitaet Stuttgart, Institute for Systems Theory and Automatic Control, Stuttgart (Germany); Dai, Ran; Mesbahi, Mehran [University of Washington, Department of Aeronautics and Astronautics, Seattle, WA (United States)

    2012-06-15

    Next generation power management at all scales will rely on the efficient scheduling and operation of both generating units and loads to maximize efficiency and utility. The ability to schedule and modulate the demand levels of a subset of loads within a power system can lead to more efficient use of the generating units. These methods become increasingly important for systems that operate independently of the main utility, such as microgrid and off-grid systems. This work extends the principles of unit commitment and economic dispatch problems to off-grid power systems where the loads are also schedulable. We propose a general optimization framework for solving the energy management problem in these systems. An important contribution is the description of how a wide range of sources and loads, including those with discrete states, non-convex, and nonlinear cost or utility functions, can be reformulated as a convex optimization problem using, for example, a shortest path description. Once cast in this way, solution are obtainable using a sub-gradient algorithm that also lends itself to a distributed implementation. The methods are demonstrated by a simulation of an off-grid solar powered community. (orig.)

  10. LIFE CYCLE ASSESSMENT FOR THE PRODUCTION OF CATTLE MILK IN AN INTENSIVE SILVOPASTORAL SYSTEM AND A CONVENTIONAL SYSTEM IN COLOMBIA

    Directory of Open Access Journals (Sweden)

    Julian Esteban Rivera Herrera

    2016-12-01

    Full Text Available Currently, cattle systems have the challenge of improving their efficiency in order to satisfy the growing demand of livestock products while at the same time reducing their emissions. In order to estimate the main environmental impacts of bovine milk production and identify mitigation alternatives, a life cycle analysis (LCA was conducted to compare an intensive silvopastoral systems (ISS and a conventional system (CS in Colombia. The structure of ISO 14044 was followed, with four functional units (FU; the estimated environmental impacts were: land use (LU, use of non-renewable energy (UNRE and emissions of greenhouse gases (GHG. For all FU, the ISS had lower emissions of GHGs than the conventional system. To produce one kg of fat- and protein-corrected milk (FPCM the ISS emitted 1 less GHG than the CS (2.05 vs. 2.34 kg CO2-eq. Regarding the use of non-renewable energy, the ISS required only 63% of the energy used in the CS to produce one kg FPCM (3.64 vs. 5.81 kg Mj-1 whilst for land use, the CS was more efficient in all UF compared to the ISS. We conclude that in ISS there are lower environmental impacts per unit of product, emitting less GHG and having lower UNRE.

  11. Sensorless Reserved Power Control Strategy for Two-Stage Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    Due to still increasing penetration level of grid-connected Photovoltaic (PV) systems, advanced active power control functionalities have been introduced in grid regulations. A reserved power control, where the active power from the PV panels is reserved during operation, is required for grid...... support. In this paper, a cost-effective solution to realize the reserved power control for grid-connected PV systems is proposed. The proposed solution routinely employs a Maximum Power Point Tracking (MPPT) control to estimate the available PV power and a Constant Power Generation (CPG) control...... to achieve the power reserve. In this method, the irradiance measurements that have been used in conventional control schemes to estimate the available PV power are not required, and thereby being a sensorless solution. Simulations and experimental tests have been performed on a 3-kW two-stage single...

  12. Design of power steering systems for heavy-duty long-haul vehicles

    NARCIS (Netherlands)

    Silvas, E.; Backx, E.A.; Hofman, T.; Voets, H.; Steinbuch, M.

    2014-01-01

    Conventionally, all auxiliaries present in a heavy-duty vehicle (e.g., power-steering pump, air-conditioning compressor) are engine-driven systems, which put high constraints on their performance. Outputs (e.g., speed, temperature) and energy consumption are dictated by engine speed, while most

  13. POWER SUPPLY MANAGEMENT SYSTEM DESIGN ON NODE EARLY WARNING SYSTEM FOR PEATLANDS FIRE MITIGATION

    Directory of Open Access Journals (Sweden)

    Taufiq Muammar

    2018-02-01

    Full Text Available Early warning system is one of the technology to detect land fires by utilizing a network of wireless sensors. Constant data transmission by the sensor nodes consumes a large amount of energy on the nodes’ sides that could affect the battery’s longevity. This research is done to discover the amount of power consumption and battery longevity during fire emergencies, and during non-emergency situation on peatlands. Power saving on the fire detecting system uses an LM35 temperature sensor, ATmega8 micro-controller and HC-12 transmission module. The overall result of powered by a 9 volt battery during fire emergencies, and during non-emergency, the power consumption reaches up to 1 Wh, with various longevity levels of the battery. The implementation of sleep/wake up mode scheduling during fire emergencies and non-emergencies could save battery for 2 hours compared to those without the power saving mode implementation. Power saving during fire emergency could be minimalized by activating the sleep mode activation power-down on the micro controller and it can also set the data transmission schedule to minimalize data usage during fire emergency, so that the usage of sleep/wake up mode interval scheduling during transmission could minimalize energy consumption and elongate the power supply active period.

  14. Hybrid2 - The hybrid power system simulation model

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, E.I.; Green, H.J.; Dijk, V.A.P. van [National Renewable Energy Lab., Golden, CO (United States); Manwell, J.F. [Univ. of Massachusetts, Amherst, MA (United States)

    1996-12-31

    There is a large-scale need and desire for energy in remote communities, especially in the developing world; however the lack of a user friendly, flexible performance prediction model for hybrid power systems incorporating renewables hindered the analysis of hybrids as options to conventional solutions. A user friendly model was needed with the versatility to simulate the many system locations, widely varying hardware configurations, and differing control options for potential hybrid power systems. To meet these ends, researchers from the National Renewable Energy Laboratory (NREL) and the University of Massachusetts (UMass) developed the Hybrid2 software. This paper provides an overview of the capabilities, features, and functionality of the Hybrid2 code, discusses its validation and future plans. Model availability and technical support provided to Hybrid2 users are also discussed. 12 refs., 3 figs., 4 tabs.

  15. APR1400 Electrical Power System Conformance to SECY-91-078

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Che-Wung; Kim, Yun-Ho [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    In this paper, the APR1400 electric power system for NRC-DC was described. In addition, the conformance to SECY 91-078 was evaluated. Enclosure 1 of the SECY provides an overview of the issue and states that the staff concludes that feeding the safety buses from the offsite power sources through non-safety buses or from a common transformer winding with non-safety loads is not the most reliable configuration. Such an arrangement increases the difficulty in properly regulating voltage at the safety buses, subjects the safety loads to transients caused by the non-safety loads, and adds additional failure points between the offsite power sources and safety loads. Therefore, it is the staff’s position that at least one offsite circuit to each redundant safety division should be supplied directly from one of the offsite power sources with no intervening non-safety buses, in such a manner that the offsite source can power the safety buses upon a failure of any non-safety bus. The APR1400 does not have an intervening nonsafety bus in the current offsite to onsite electrical configuration; however, the design does include nonsafety and safety buses coming from the same secondary side 4.16 kV transformer winding. Nevertheless, the APR1400 has designed the electrical interface system between offsite and onsite power with enhanced reliability measures to ensure that the nonsafety system will not impact the safety loads. The design complies with GDC 17 and also conforms to SECY-91-078.

  16. Multiobjective clearing of reactive power market in deregulated power systems

    International Nuclear Information System (INIS)

    Rabiee, A.; Shayanfar, H.; Amjady, N.

    2009-01-01

    This paper presents a day-ahead reactive power market which is cleared in the form of multiobjective context. Total payment function (TPF) of generators, representing the payment paid to the generators for their reactive power compensation, is considered as the main objective function of reactive power market. Besides that, voltage security margin, overload index, and also voltage drop index are the other objective functions of the optimal power flow (OPF) problem to clear the reactive power market. A Multiobjective Mathematical Programming (MMP) formulation is implemented to solve the problem of reactive power market clearing using a fuzzy approach to choose the best compromise solution according to the specific preference among various non-dominated (pareto optimal) solutions. The effectiveness of the proposed method is examined based on the IEEE 24-bus reliability test system (IEEE 24-bus RTS). (author)

  17. reactor power control using fuzzy logic

    International Nuclear Information System (INIS)

    Ahmed, A.E.E.

    2001-01-01

    power stabilization is a critical issue in nuclear reactors. convention pd- controller is currently used in egypt second testing research reactor (ETRR-2). two fuzzy controllers are proposed to control the reactor power of ETRR-2 reactor. the design of the first one is based on a set of linguistic rules that were adopted from the human operators experience. after off-line fuzzy computations, the controller is a lookup table, and thus, real time controller is achieved. comparing this f lc response with the pd-controller response, which already exists in the system, through studying the expected transients during the normal operation of ETRR-2 reactor, the simulation results show that, fl s has the better response, the second controller is adaptive fuzzy controller, which is proposed to deal with system non-linearity . The simulation results show that the proposed adaptive fuzzy controller gives a better integral square error (i se) index than the existing conventional od controller

  18. Reduced Cost of Reactive Power in Doubly Fed Induction Generator Wind Turbine System with Optimized Grid Filter

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Franke, Toke

    2014-01-01

    The modern grid requirement has caused that the wind power system behaves more like conventional rotating generators and it is able to support certain amount of the reactive power. For a typical doubly-fed induction generator wind turbine system, the reactive power can be supported either through...... for the generator and the wind power converter in terms of the reactive power done by the rotor-side converter or the grid-side converter with various grid filters. Afterwards, the annual energy loss is also estimated based on yearly wind profile. Finally, experimental results of the loss distribution are performed...... the rotor-side converter or the grid-side converter. This paper firstly compares the current ripples and supportive reactive power ranges between the conventional L and optimized LCL filter, if the reactive power is injected from the grid-side converter. Then, the loss distribution is evaluated both...

  19. Reduced Cost of Reactive Power in Doubly Fed Induction Generator Wind Turbine System With Optimized Grid Filter

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Franke, Toke

    2015-01-01

    The modern grid requirement has caused that the wind power system behaves more like conventional rotating generators, and it is able to support certain amount of the reactive power. For a typical doubly fed induction generator (DFIG) wind turbine system, the reactive power can be supported either...... for the generator and the wind power converter in terms of the reactive power done by the rotor-side converter or the grid-side converter with various grid filters. Afterward, the annual energy loss is also estimated based on yearly wind profile. Finally, experimental results of the loss distribution are performed...... through the rotor-side converter or the grid-side converter. This paper first compares the current ripples and supportive reactive power ranges between the conventional L and optimized LCL filter, if the reactive power is injected from the grid-side converter. Then, the loss distribution is evaluated both...

  20. Autonomous power networks based power system

    International Nuclear Information System (INIS)

    Jokic, A.; Van den Bosch, P.P.J.

    2006-01-01

    This paper presented the concept of autonomous networks to cope with this increased complexity in power systems while enhancing market-based operation. The operation of future power systems will be more challenging and demanding than present systems because of increased uncertainties, less inertia in the system, replacement of centralized coordinating activities by decentralized parties and the reliance on dynamic markets for both power balancing and system reliability. An autonomous network includes the aggregation of networked producers and consumers in a relatively small area with respect to the overall system. The operation of an autonomous network is coordinated and controlled with one central unit acting as an interface between internal producers/consumers and the rest of the power system. In this study, the power balance problem and system reliability through provision of ancillary services was formulated as an optimization problem for the overall autonomous networks based power system. This paper described the simulation of an optimal autonomous network dispatching in day ahead markets, based on predicted spot prices for real power, and two ancillary services. It was concluded that large changes occur in a power systems structure and operation, most of them adding to the uncertainty and complexity of the system. The introduced concept of an autonomous power network-based power system was shown to be a realistic and consistent approach to formulate and operate a market-based dispatch of both power and ancillary services. 9 refs., 4 figs

  1. Energy-Efficient Power Allocation for MIMO-SVD Systems

    KAUST Repository

    Sboui, Lokman

    2017-05-24

    In this paper, we address the problem of energyefficient power allocation in MIMO systems. In fact, the widely adopted water-filling power allocation does not ensure the maximization of the energy efficiency (EE). Since the EE maximization is a non-convex problem, numerical methods based on fractional programming were introduced to find the optimal power solutions. In this paper, we present a novel and simple power allocation scheme based on the explicit expressions of the optimal power. We also present a low-complexity algorithm that complements the proposed scheme for low circuit-power regime. Furthermore, we analyze power-constrained and rate-constrained systems and present the corresponding optimal power control. In the numerical results, we show that the presented analytical expressions are accurate and that the algorithm converges within two iterations. We also show that as the number of antenna increases, the system becomes more energy-efficient. Also, a saturation of the EE is observed at high power budget and low minimal rate regimes.

  2. Solar-powered cooling system

    Science.gov (United States)

    Farmer, Joseph C.

    2015-07-28

    A solar-powered adsorption-desorption refrigeration and air conditioning system that uses nanostructural materials such as aerogels, zeolites, and sol gels as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material while the material is at a relatively low temperature, perhaps at night. During daylight hours, when the nanostructural materials is heated by the sun, the refrigerant are thermally desorbed from the surface of the aerogel, thereby creating a pressurized gas phase in the vessel that contains the aerogel. This solar-driven pressurization forces the heated gaseous refrigerant through a condenser, followed by an expansion valve. In the condenser, heat is removed from the refrigerant, first by circulating air or water. Eventually, the cooled gaseous refrigerant expands isenthalpically through a throttle valve into an evaporator, in a fashion similar to that in more conventional vapor recompression systems.

  3. Spallation Neutron Source Accelerator Facility Target Safety and Non-safety Control Systems

    International Nuclear Information System (INIS)

    Battle, Ronald E.; DeVan, B.; Munro, John K. Jr.

    2006-01-01

    The Spallation Neutron Source (SNS) is a proton accelerator facility that generates neutrons for scientific researchers by spallation of neutrons from a mercury target. The SNS became operational on April 28, 2006, with first beam on target at approximately 200 W. The SNS accelerator, target, and conventional facilities controls are integrated by standardized hardware and software throughout the facility and were designed and fabricated to SNS conventions to ensure compatibility of systems with Experimental Physics Integrated Control System (EPICS). ControlLogix Programmable Logic Controllers (PLCs) interface to instruments and actuators, and EPICS performs the high-level integration of the PLCs such that all operator control can be accomplished from the Central Control room using EPICS graphical screens that pass process variables to and from the PLCs. Three active safety systems were designed to industry standards ISA S84.01 and IEEE 603 to meet the desired reliability for these safety systems. The safety systems protect facility workers and the environment from mercury vapor, mercury radiation, and proton beam radiation. The facility operators operated many of the systems prior to beam on target and developed the operating procedures. The safety and non-safety control systems were tested extensively prior to beam on target. This testing was crucial to identify wiring and software errors and failed components, the result of which was few problems during operation with beam on target. The SNS has continued beam on target since April to increase beam power, check out the scientific instruments, and continue testing the operation of facility subsystems

  4. Comparative studies on conventional (water-hot acid) and non-conventional (ultrasonication) procedures for extraction and chemical characterization of pectin from peel waste of mango cultivar chaunsa

    International Nuclear Information System (INIS)

    Kausar, S.; Saeed, A.

    2015-01-01

    Pectin, a naturally occurring heteropolysaccharide, is widely used as a functional ingredient in food and pharmaceutical industries due to its gelling and stabilizing properties. During the present study pectin was extracted from peel of mango (cultivar Chaunsa) using conventional (water-hot acid) and non-conventional (ultrasonication) methods. In conventional method, HNO/sub 3/, H/sub 2/SO/sub 4/, or HCl was used under variable conditions of pH (2.0, 2.5, 3.0), temperature (70, 80, 90, 100 degree C), duration of extraction (30, 60, 90, 120 min), and solvents (ethanol, methanol, acetone, isopropyl alcohol). Maximum yield of 16.6 g pectin 100 g/sup -1/ peel was obtained with HNO/sub 3/ at pH 2.5, 90 degree C, 90 min extraction, and ethanol. Whereas in non-conventional method, ultrasonication was used for different time intervals (10, 20, 40 min) using HNO/sub 3/ at pH 2.5 and 90 degree C. Maximum yield of 15.8 g pectin 100 g/sup -1/ peel was obtained by this method in 20 min. Pectin extracted by the above two methods was found to be of high quality as was determined in respect of methoxyl and galacturonic acid contents, degree of esterification, equivalent weight, and FTIR spectra. Extraction of pectin from mango peel by employing non-conventional method (ultrasonication) was observed to be an energy efficient method due to its less extraction time (20 min as compared to 90 min in conventional method) suggesting its suitability on commercial scale for the extraction of pectin from mango and other available fruit peel wastes. (author)

  5. Transient Processes in Electric Power Supply System for Oil Terminal with Own Gas-Turbine Power Station

    Directory of Open Access Journals (Sweden)

    A. M. Hаshimov

    2009-01-01

    Full Text Available The paper contains results of the investigations concerning influence of symmetrical and non-symmetrical short circuits at main power network on electric power supply system of a huge oil terminal which is powered by own gas-turbine power station. Calculations have been made in accordance with the IEC and IEEЕ requirements. Estimations for voltage level and distribution of short circuit current in the electric power supply system of the Sangachal oil terminal being operated in parallel with the AzerEnerji grid are presented in the paper

  6. Conceptual design and analysis of a Dish-Rankine solar thermal power system

    Science.gov (United States)

    Pons, R. L.

    1980-08-01

    A Point Focusing Distributed Receiver (PFDR) solar thermal electric system which employs small Organic Rankine Cycle (ORC) engines is examined with reference to its projected technical/economic performance. With mass-produced power modules (about 100,000 per year), the projected life-cycle energy cost for an optimized no-storage system is estimated at 67 mills/kWh (Levelized Busbar Energy Cost) without the need for advanced development of any of its components. At moderate production rates (about 50 MWe/yr) system energy costs are competitive with conventional power generation systems in special remote-site types of applications.

  7. Power System Simulation for Policymaking and Making Policymakers

    Science.gov (United States)

    Cohen, Michael Ari

    Power system simulation is a vital tool for anticipating, planning for and ultimately addressing future conditions on the power grid, especially in light of contemporary shifts in power generation, transmission and use that are being driven by a desire to utilize more environmentally responsible energy sources. This dissertation leverages power system simulation and engineering-economic analysis to provide initial answers to one open question about future power systems: how will high penetrations of distributed (rooftop) solar power affect the physical and economic operation of distribution feeders? We find that the overall impacts of distributed solar power (both positive and negative) on the feeders we modeled are minor compared to the overall cost of energy, but that there is on average a small net benefit provided by distributed generation. We then describe an effort to make similar analyses more accessible to a non-engineering (high school) audience by developing an educational video game called "Griddle" that is based on the same power system simulation techniques used in the first study. We describe the design and evaluation of Griddle and find that it demonstrates potential to provide students with insights about key power system learning objectives.

  8. Aggregated wind power generation probabilistic forecasting based on particle filter

    International Nuclear Information System (INIS)

    Li, Pai; Guan, Xiaohong; Wu, Jiang

    2015-01-01

    Highlights: • A new method for probabilistic forecasting of aggregated wind power generation. • A dynamic system is established based on a numerical weather prediction model. • The new method handles the non-Gaussian and time-varying wind power uncertainties. • Particle filter is applied to forecast predictive densities of wind generation. - Abstract: Probability distribution of aggregated wind power generation in a region is one of important issues for power system daily operation. This paper presents a novel method to forecast the predictive densities of the aggregated wind power generation from several geographically distributed wind farms, considering the non-Gaussian and non-stationary characteristics in wind power uncertainties. Based on a mesoscale numerical weather prediction model, a dynamic system is established to formulate the relationship between the atmospheric and near-surface wind fields of geographically distributed wind farms. A recursively backtracking framework based on the particle filter is applied to estimate the atmospheric state with the near-surface wind power generation measurements, and to forecast the possible samples of the aggregated wind power generation. The predictive densities of the aggregated wind power generation are then estimated based on these predicted samples by a kernel density estimator. In case studies, the new method presented is tested on a 9 wind farms system in Midwestern United States. The testing results that the new method can provide competitive interval forecasts for the aggregated wind power generation with conventional statistical based models, which validates the effectiveness of the new method

  9. Statistical modeling to support power system planning

    Science.gov (United States)

    Staid, Andrea

    This dissertation focuses on data-analytic approaches that improve our understanding of power system applications to promote better decision-making. It tackles issues of risk analysis, uncertainty management, resource estimation, and the impacts of climate change. Tools of data mining and statistical modeling are used to bring new insight to a variety of complex problems facing today's power system. The overarching goal of this research is to improve the understanding of the power system risk environment for improved operation, investment, and planning decisions. The first chapter introduces some challenges faced in planning for a sustainable power system. Chapter 2 analyzes the driving factors behind the disparity in wind energy investments among states with a goal of determining the impact that state-level policies have on incentivizing wind energy. Findings show that policy differences do not explain the disparities; physical and geographical factors are more important. Chapter 3 extends conventional wind forecasting to a risk-based focus of predicting maximum wind speeds, which are dangerous for offshore operations. Statistical models are presented that issue probabilistic predictions for the highest wind speed expected in a three-hour interval. These models achieve a high degree of accuracy and their use can improve safety and reliability in practice. Chapter 4 examines the challenges of wind power estimation for onshore wind farms. Several methods for wind power resource assessment are compared, and the weaknesses of the Jensen model are demonstrated. For two onshore farms, statistical models outperform other methods, even when very little information is known about the wind farm. Lastly, chapter 5 focuses on the power system more broadly in the context of the risks expected from tropical cyclones in a changing climate. Risks to U.S. power system infrastructure are simulated under different scenarios of tropical cyclone behavior that may result from climate

  10. Power electronics and control for wind power systems

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede

    2009-01-01

    energy at the end-user should be set up. Deregulation of energy has lowered the investment in larger power plants, which means the need for new electrical power sources may be increased in the near future. Two major technologies will play important roles to solve the future problems. One is to change......The global electrical energy consumption is still rising and there is a steady demand to increase the power capacity. It is expected that it has to be doubled within 20 years. The production, distribution and use of the energy should be as technological efficient as possible and incentives to save...... the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. Another is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most emerging...

  11. Battery Recharging Issue for a Two-Power-Level Flywheel System

    Directory of Open Access Journals (Sweden)

    Janaína Gonçalves de Oliveira

    2010-01-01

    Full Text Available A novel battery recharging system for an all-electric driveline comprising a flywheel with a permanent magnet double wound synchronous machine (motor/generator is presented. The double winding enables two voltage levels and two different power levels. This topology supersedes other all-electric drivelines. The battery operates in a low-power regime supplying the average power whereas the flywheel delivers and absorbs power peaks, which are up to a higher order of magnitude. The topology presents new challenges for the power conversion system, which is the focus of this investigation. The main challenge is the control of the power flow to the battery when the vehicle is parked despite the decay of the flywheel machine voltage; which is dependent on its charge state, that is, rotational speed. The design and simulation of an unidirectional DC/DC buck/boost converter for a variable rotational speed flywheel is presented. Conventional power electronic converters are used in a new application, which can maintain a constant current or voltage on the battery side. Successful PI current control has been implemented and simulated, together with the complete closed loop system.

  12. Fault tolerance of the NIF power conditioning system

    International Nuclear Information System (INIS)

    Larson, D.W.; Anderson, R.; Boyes, J.

    1995-01-01

    The tolerance of the circuit topology proposed for the National Ignition Facility (NIF) power conditioning system to specific fault conditions is investigated. A new pulsed power circuit is proposed for the NIF which is simpler and less expensive than previous ICF systems. The inherent fault modes of the new circuit are different from the conventional approach, and must be understood to ensure adequate NIF system reliability. A test-bed which simulates the NIF capacitor module design was constructed to study the circuit design. Measurements from test-bed experiments with induced faults are compared with results from a detailed circuit model. The model is validated by the measurements and used to predict the behavior of the actual NIF module during faults. The model can be used to optimize fault tolerance of the NIF module through an appropriate distribution of circuit inductance and resistance. The experimental and modeling results are presented, and fault performance is compared with the ratings of pulsed power components. Areas are identified which require additional investigation

  13. Applying model predictive control to power system frequency control

    OpenAIRE

    Ersdal, AM; Imsland, L; Cecilio, IM; Fabozzi, D; Thornhill, NF

    2013-01-01

    16.07.14 KB Ok to add accepted version to Spiral Model predictive control (MPC) is investigated as a control method which may offer advantages in frequency control of power systems than the control methods applied today, especially in presence of increased renewable energy penetration. The MPC includes constraints on both generation amount and generation rate of change, and it is tested on a one-area system. The proposed MPC is tested against a conventional proportional-integral (PI) cont...

  14. Tidal Energy System for On-Shore Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Bruce, Allan J

    2012-06-26

    Addressing the urgent need to develop LCOE competitive renewable energy solutions for US energy security and to replace fossil-fuel generation with the associated benefits to environment impacts including a reduction in CO2 emissions, this Project focused on the advantages of using hydraulic energy transfer (HET) in large-scale Marine Hydrokinetic (MHK) systems for harvesting off-shore tidal energy in US waters. A recent DOE resource assessment, identifies water power resources have a potential to meet 15% of the US electric supply by 2030, with MHK technologies being a major component. The work covered a TRL-4 laboratory proof-in-concept demonstration plus modeling of a 15MW full scale system based on an approach patented by NASA-JPL, in which submerged high-ratio gearboxes and electrical generators in conventional MHK turbine systems are replaced by a submerged hydraulic radial pump coupled to on-shore hydraulic motors driving a generator. The advantages are; first, the mean-time-between-failure (MTBF), or maintenance, can be extended from approximately 1 to 5 years and second, the range of tidal flow speeds which can be efficiently harvested can be extended beyond that of a conventional submerged generator. The approach uses scalable, commercial-off-the-shelf (COTS) components, facilitating scale-up and commercialization. All the objectives of the Project have been successfully met (1) A TRL4 system was designed, constructed and tested. It simulates a tidal energy turbine, with a 2-m diameter blade in up to a 2.9 m/sec flow. The system consists of a drive motor assembly providing appropriate torque and RPM, attached to a radial piston pump. The pump circulates pressurized, environmentally-friendly, HEES hydraulic fluid in a closed loop to an axial piston motor which drives an electrical generator, with a resistive load. The performance of the components, subsystems and system were evaluated during simulated tidal cycles. The pump is contained in a tank for

  15. Stockholm Power Tech. Power systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The proceedings from this symposium is presented in six volumes: Invited speakers` sessions; Power systems; Power electronics; High-voltage technology; Electrical machines and drives; and Information and control systems. This report covers the power systems volume. Separate abstracts have been prepared for 141 of the 145 papers in this volume

  16. Stockholm Power Tech. Power systems

    International Nuclear Information System (INIS)

    1995-01-01

    The proceedings from this symposium is presented in six volumes: Invited speakers' sessions; Power systems; Power electronics; High-voltage technology; Electrical machines and drives; and Information and control systems. This report covers the power systems volume. Separate abstracts have been prepared for 141 of the 145 papers in this volume

  17. Large Banks of Negative Differential Resistance Nonlinear Loads: A Hidden Threat to Power System Quality

    Directory of Open Access Journals (Sweden)

    Mahmood Ahmad

    2018-01-01

    Full Text Available DSM (Demand Side Management is a short term and comparatively low cost solution for energy starved countries. Replacement of IB (Incandescent Bulbs with CFL (Compact Fluorescent Lamps has proved its success throughout the world. The same solution, at larger scale, was proposed to Pakistan to mitigate power shortage on short term basis. Accordingly in year 2008, ADB (Asian Development Bank conducted a study and it was found that replacement of conventional IB with 30 million CFL will result into series of benefits for the stake holders and above all the Environment. The study, unfortunately didn’t take enough consideration of effect of CFLs on the power system being nonlinear device and so the power quality issues remained a secondary consideration. The focus of this paper remains on the effect of such non-linear load on consumers, it also envisages the erratic behaviour of such large penetration of CFLs on direct single phase, three phase, digital as well as electromechanical energy meters, under different loading conditions e.g. resistive load, SMPS (Switch Mode Power Supply, half and full-wave rectifiers. It also reflects harmonic pollution caused by CFLs, their effect on power system quality and the registration ability of electromechanical as well as digital energy meters. To this end Harmonic spectrum was recorded up to the 31st harmonic.

  18. Study of greenhouse gases reduction alternatives for the exploitation of non conventional oil sands in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Bouchonneau, Deborah [Institut Francais du Petrole (IFP), Paris (France)

    2008-07-01

    High energy prices and greenhouse gases reduction represent the main challenges the current worldwide energetic situation has to face. As a consequence, paradox strategies can be highlighted: oil prices are sufficiently high to exploit non conventional oil resources, like extra heavy oils and oil sands. But the production of these resources emits larger GHG than the conventional oil path and implies other major environmental issues (water management, risks of soil pollution, destruction of the boreal forest), incompatible with the rules validated by the protocol of Kyoto. At the light of the new greenhouse gases reduction regulation framework announced by the Canadian Federal government, this work focuses on the study of greenhouse gases reduction alternatives applied to the non conventional oil sands exploitation in Canada. (author)

  19. Solar power generation system. Solar denryoku hassei sochi

    Energy Technology Data Exchange (ETDEWEB)

    Ohaku, T [Toshiba Corp., Kawasaki (Japan)

    1990-12-21

    In a conventional solar power generation system having shunt elements for controlling generated power and supplying the controlled power to a load, it is difficult to carry out a stable power control, because the shunt characteristics of an analogue shunt element driving circuit vary widely as compared with a digital shunt element driving circuit, as the temperature varies. According to the present invention, in a solar power generation system having a plurality of solar cells divided into two of the first and second cell groups and a first and a second shunt element driving means provided for the first and second cell groups, the first shunt element driving means is composed of a combination of a resisance and level shift diode arranged, and the second shunt element driving means is composed of a combination of a transistor and level shift diode arranged. A stable current control of the shunt elements can be therefore realized, because the control voltage range of the first and second shunt element driving means is changed so as to be expanded, as the temperature varies, so that their overlapped voltage range is kept constant. 7 figs.

  20. Power Electronics and Controls for Wind Turbine Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Iov, Florin; Chen, Zhe

    2010-01-01

    term) based energy sources to renewable energy sources. Another is to use power electronics to achieve high efficiency in power generation, transmission/distribution and utilization. This paper discuss trends of the most promising renewable energy sources, wind energy, which ,integrated with power...... electronics, is changing the future electrical infrastructure and also contributes steadily to non-carbon based electricity production. The paper’s focus is on the power electronics technologies used in wind turbine systems....

  1. Decentralized automatic generation control of interconnected power systems incorporating asynchronous tie-lines.

    Science.gov (United States)

    Ibraheem; Hasan, Naimul; Hussein, Arkan Ahmed

    2014-01-01

    This Paper presents the design of decentralized automatic generation controller for an interconnected power system using PID, Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The designed controllers are tested on identical two-area interconnected power systems consisting of thermal power plants. The area interconnections between two areas are considered as (i) AC tie-line only (ii) Asynchronous tie-line. The dynamic response analysis is carried out for 1% load perturbation. The performance of the intelligent controllers based on GA and PSO has been compared with the conventional PID controller. The investigations of the system dynamic responses reveal that PSO has the better dynamic response result as compared with PID and GA controller for both type of area interconnection.

  2. DC microgrids with energy storage systems and demand response for providing support to frequency regulation of electrical power systems

    DEFF Research Database (Denmark)

    Basic, Hrvoje; Dragicevic, Tomislav; Pandzic, Hrvoje

    2017-01-01

    Frequency regulation of electric power systems efficiency depends on response time and on power reserves for frequency regulation. As integration of non-dispatchable renewable generation in the power system results with increased need for power reserves from fast responding power units, the idea ...

  3. Design optimization of photovoltaic powered water pumping systems

    International Nuclear Information System (INIS)

    Ghoneim, A.A.

    2006-01-01

    The use of photovoltaics as the power source for pumping water is one of the most promising areas in photovoltaic applications. With the increased use of water pumping systems, more attention has been paid to their design and optimum utilization in order to achieve the most reliable and economical operation. This paper presents the results of performance optimization of a photovoltaic powered water pumping system in the Kuwait climate. The direct coupled photovoltaic water pumping system studied consists of the PV array, DC motor, centrifugal pump, a storage tank that serves a similar purpose to battery storage and a maximum power point tracker to improve the efficiency of the system. The pumped water is desired to satisfy the domestic needs of 300 persons in a remote area in Kuwait. Assuming a figure of 40 l/person/day for water consumption, a volume of 12 m 3 should be pumped daily from a deep well throughout the year. A computer simulation program is developed to determine the performance of the proposed system in the Kuwait climate. The simulation program consists of a component model for the PV array with maximum power point tracker and component models for both the DC motor and the centrifugal pump. The five parameter model is adapted to simulate the performance of amorphous silicon solar cell modules. The size of the PV array, PV array orientation and the pump-motor-hydraulic system characteristics are varied to achieve the optimum performance for the proposed system. The life cycle cost method is implemented to evaluate the economic feasibility of the optimized photovoltaic powered water pumping system. At the current prices of PV modules, the cost of the proposed photovoltaic powered water pumping system is found to be less expensive than the cost of the conventional fuel system. In addition, the expected reduction in the prices of photovoltaic modules in the near future will make photovoltaic powered water pumping systems more feasible

  4. Survey and analysis on environmental and electromagnetic effect on instrumentation and control equipment of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Koo; Lee, Dong Young; Cha, Kyung Ho

    2001-03-01

    As the instrumentation and control (I and C) equipment suppliers tend to provide digital components rather than conventional analog type components for instrumentation and control systems of nuclear power plants(NPPs), it is unavoidable to adopt digital equipment for safety I and C systems as well as non-safety systems. However, the full introduction of digital equipment for I and C systems of nuclear power plants raises several concerns which have not been considered in conventional analog I and C equipment. The two major examples of the issues of digital systems are environmental/electromagnetic compatibility (EMC) and software reliability. This report presents the survey and research results on environmental and electromagnetic effect on I and C equipment of nuclear power plants to give a guideline for aging management and design process. Electromagnetic site surveys were conducted to be used as a part of technical basis to demonstrate that I and C systems are compatible with the ambient electromagnetic noise in Korean nuclear power plants.

  5. Using SMES as a multi-purpose interface in power generation, transmission and distribution systems

    International Nuclear Information System (INIS)

    Tam, K.S.; Zhang, X.; Yarali, A.

    1991-01-01

    This paper presents a new SMES schemes, the MSMES system, which significantly broadens the ways in which SMES can be applied to electric power systems. On the generation side, the SMES system can convert low-quality power into high-quality power and enhances the utilization of all energy sources available to the power systems. Acting both as an energy storage device and a power flow control device, a MSMES system can act as a hub in a power transmission system. The use of multiple MSMES systems can provide many new solutions to the problems facing the transmission networks of the United States today. On the distribution side, MSMES systems can be used as advanced power distribution centers that supply high-quality power to the customers while providing desirable load shapes to the power systems. In addition to these functions, a MSMES unit can also perform functions such as damping of power oscillation, stability and dynamic performance improvement and other recognized benefits of the conventional SMES system. Functioning as a multi-purpose power processing units, the MSMES systems improve the economics of SMES system. Functioning as a multi-purpose power processing units, the MSMES systems improve the economics of SMES technology and expand its potential market

  6. Conventional control and fuzzy control of a dc-dc converter for machine drive

    Energy Technology Data Exchange (ETDEWEB)

    Radoi, C.; Florescu, A. [Department of Power Electronics `Politecnica` University Bucharest (Romania)

    1997-12-31

    Fuzzy logic or fuzzy set theory is recently getting increasing emphasis in process control applications. The paper describes an application of fuzzy logic in speed control system that uses a dc-dc converter. The fuzzy control is used to linearize the family of external characteristics of the converter in discontinuous-conduction mode occurring at light load and/or high speed. In order to compare the conventional control with the fuzzy logic control, algorithms have been developed in detail and verified by Microsoft Excel simulation. The simulation study indicates that fuzzy control is a good alternative for conventional control methods, being used particularly in non-linear complex systems ill defined or totally unknown. Where the mathematical model exists, it is useful. The applications of fuzzy set theory in power electronics are almost entirely new; fuzzy logic seems to have a lot of premises in the large industrial control field. (orig.) 2 refs.

  7. A two-hop wireless power transfer system with an efficiency-enhanced power receiver for motion-free capsule endoscopy inspection.

    Science.gov (United States)

    Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Zhihua

    2012-11-01

    This paper presents a wireless power transfer system for a motion-free capsule endoscopy inspection. Conventionally, a wireless power transmitter in a specifically designed jacket has to be connected to a strong power source with a long cable. To avoid the power cable and allow patients to walk freely in a room, this paper proposes a two-hop wireless power transfer system. First, power is transferred from a floor to a power relay in the patient's jacket via strong coupling. Next, power is delivered from the power relay to the capsule via loose coupling. Besides making patients much more conformable, the proposed techniques eliminate the sources of reliability issues arisen from the moving cable and connectors. In the capsule, it is critical to enhance the power conversion efficiency. This paper develops a switch-mode rectifier (rectifying efficiency of 93.6%) and a power combination circuit (enhances combining efficiency by 18%). Thanks to the two-hop transfer mechanism and the novel circuit techniques, this system is able to transfer an average power of 24 mW and a peak power of 90 mW from the floor to a 13 mm × 27 mm capsule over a distance of 1 m with the maximum dc-to-dc power efficiency of 3.04%.

  8. Non-steady experimental investigation on an integrated thermal management system for power battery with phase change materials

    International Nuclear Information System (INIS)

    Shi, Shang; Xie, Yongqi; Li, Ming; Yuan, Yanping; Yu, Jianzu; Wu, Hongwei; Liu, Bin; Liu, Nan

    2017-01-01

    Highlights: • An integrated thermal management system for power battery is designed. • The battery temperature rise is a non-steady process for charge and discharge. • A mathematical model can accurately represent temperature rise characteristics. • The heat generation power of the battery is calculated theoretically. • The excess temperatures and thermal resistances affect the system performance. - Abstract: A large amount of heat inside the power battery must be dissipated to maintain the temperature in a safe range for the hybrid power train during high-current charging/discharging processes. In this article, a combined experimental and theoretical study has been conducted to investigate a newly designed thermal management system integrating phase change material with air cooling. An unsteady mathematical model was developed for the battery with the integrated thermal management system. Meanwhile, the heat generation power, thermal resistance, and time constant were calculated. The effect of several control parameters, such as thermal resistance, initial temperature, melting temperature and ambient temperature, on the performance of the integrated thermal management system were analyzed. The results indicated that: (1) the calculated temperature rise of the battery was in good agreement with the experimental data. The appropriate operation temperature of the battery was attained by the action of the phase change storage energy unit which is composed of copper foam and n-Eicosane, (2) the remarkable decrease of the battery temperature can be achieved by reducing the convection thermal resistance or increasing the conductivity of the phase change storage energy unit, where the latter could be the better option due to no additional energy consumption. When convective resistance and thermal resistance between the battery surface and the phase change storage energy unit are less than 2.03 K/W and 1.85 K/W, respectively, the battery will not exceed the

  9. Electric power system / emergency power supply

    International Nuclear Information System (INIS)

    Dorn, P.G.

    1980-01-01

    One factor of reliability of reactor safety systems is the integrity of the power supply. The purpose of this paper is a review and a discussion of the safety objectives required for the planning, licensing, manufacture and erection of electrical power systems and components. The safety aspects and the technical background of the systems for - the electric auxiliary power supply system and - the emergency power supply system are outlined. These requirements result specially from the safety standards which are the framework for the studies of safety analysis. The overall and specific requirements for the electrical power supply of the safety systems are demonstrated on a 1300 MW standard nuclear power station with a pressurized water reactor. (orig.)

  10. Comparison of the adverse event profiles of conventional and liposomal formulations of doxorubicin using the FDA adverse event reporting system.

    Science.gov (United States)

    Fukuda, Akiho; Tahara, Kohei; Hane, Yuuki; Matsui, Toshinobu; Sasaoka, Sayaka; Hatahira, Haruna; Motooka, Yumi; Hasegawa, Shiori; Naganuma, Misa; Abe, Junko; Nakao, Satoshi; Takeuchi, Hirofumi; Nakamura, Mitsuhiro

    2017-01-01

    Doxorubicin (DOX) is an anthracycline widely used for the treatment of solid and hematological tumors. The aim of this study was to assess the adverse event profiles of conventional DOX and liposomal DOX. This is the first study to evaluate the effect of a liposomal formulation of DOX using spontaneous reporting system (SRS) databases. The SRS used was the US Food and Drug Administration Adverse Event Reporting System (FAERS). This study relied on definitions of preferred terms provided by the Medical Dictionary for Regulatory Activities (MedDRA) and the standardized MedDRA Queries (SMQ) database. We also calculated the reporting odds ratios (RORs) of suspected drugs (conventional DOX; PEGylated-liposome DOX; non-PEGylated-liposome DOX). The FAERS database contained 7,561,254 reports from January 2004 to December 2015. The number of reported AE cases for conventional DOX, PEGylated-liposome DOX, and non-PEGylated-liposome DOX was 5039, 3780, and 349, respectively. Conventional DOX and liposomal DOX have potential risks of causing myelosuppression, cardiotoxicity, alopecia, nausea, and vomiting, among other effects. The RORs (95% CI) from SMQ for haematopoietic leucopenia associated with conventional DOX, PEGylated-liposome DOX, and non-PEGylated-liposome DOX were 12.75 (11.89-13.68), 6.43 (5.81-7.13), and 14.73 (11.42-18.99), respectively. Liposomal DOX formulations were associated with lower RORs with regard to myelosuppression, cardiotoxicity, and alopecia than the conventional DOX was. The RORs (95% CI) for palmar-plantar erythrodysesthesia (PPE) associated with conventional DOX, PEGylated-liposome DOX, and non-PEGylated-liposome DOX were 6.56 (4.74-9.07), 64.77 (56.84-73.80), and 28.76 (15.77-52.45), respectively. This study is the first to evaluate the relationship between DOX liposomal formulations and their adverse event profiles. The results indicate that careful observation for PPE is recommended with the use of liposomal DOX, especially PEGylated

  11. Comparison of the adverse event profiles of conventional and liposomal formulations of doxorubicin using the FDA adverse event reporting system.

    Directory of Open Access Journals (Sweden)

    Akiho Fukuda

    Full Text Available Doxorubicin (DOX is an anthracycline widely used for the treatment of solid and hematological tumors. The aim of this study was to assess the adverse event profiles of conventional DOX and liposomal DOX. This is the first study to evaluate the effect of a liposomal formulation of DOX using spontaneous reporting system (SRS databases. The SRS used was the US Food and Drug Administration Adverse Event Reporting System (FAERS. This study relied on definitions of preferred terms provided by the Medical Dictionary for Regulatory Activities (MedDRA and the standardized MedDRA Queries (SMQ database. We also calculated the reporting odds ratios (RORs of suspected drugs (conventional DOX; PEGylated-liposome DOX; non-PEGylated-liposome DOX. The FAERS database contained 7,561,254 reports from January 2004 to December 2015. The number of reported AE cases for conventional DOX, PEGylated-liposome DOX, and non-PEGylated-liposome DOX was 5039, 3780, and 349, respectively. Conventional DOX and liposomal DOX have potential risks of causing myelosuppression, cardiotoxicity, alopecia, nausea, and vomiting, among other effects. The RORs (95% CI from SMQ for haematopoietic leucopenia associated with conventional DOX, PEGylated-liposome DOX, and non-PEGylated-liposome DOX were 12.75 (11.89-13.68, 6.43 (5.81-7.13, and 14.73 (11.42-18.99, respectively. Liposomal DOX formulations were associated with lower RORs with regard to myelosuppression, cardiotoxicity, and alopecia than the conventional DOX was. The RORs (95% CI for palmar-plantar erythrodysesthesia (PPE associated with conventional DOX, PEGylated-liposome DOX, and non-PEGylated-liposome DOX were 6.56 (4.74-9.07, 64.77 (56.84-73.80, and 28.76 (15.77-52.45, respectively. This study is the first to evaluate the relationship between DOX liposomal formulations and their adverse event profiles. The results indicate that careful observation for PPE is recommended with the use of liposomal DOX, especially PEGylated

  12. Analysis of a solar powered absorption system

    International Nuclear Information System (INIS)

    Said, S.A.M.; El-Shaarawi, M.A.I.; Siddiqui, M.U.

    2015-01-01

    Highlights: • Conventional absorption system modified to increase COP. • Results indicated increase of 10% in COP due to dephlegmator heat recovery. • Results indicated increase of 8% in COP due to refrigerant storage unit. • Results indicated increase of 18% in COP due to combined effect of modifications. • Simulation results indicated a very good agreement with the measured results. - Abstract: Today, fossil fuel is the primary extensively used source of energy. However, its negative impact on the environment have forced the energy research continuity to seriously consider renewable sources of energy. Solar energy, in particular, has been the main focus in this regard because it is a source of clean energy and naturally available. This study presents the design and analysis of a solar powered absorption refrigeration system modified to increase its coefficient of performance (COP). The modifications include recovering of waste heat from a dephlegmator and utilization of a refrigerant storage unit. The simulation results indicate an increase of 10% in the COP of the conventional design using dephlegmator heat recovery and an increase of 8% in the COP of the conventional design due to the use of a refrigerant storage. The analysis for the combined effect of modifications indicates an increase of 18% in the COP compared to conventional design. Calculated values of coefficient of performance indicate a very good agreement with the ones obtained based on measurement

  13. File: non conventional hydrocarbons - Between concerns and opportunities

    International Nuclear Information System (INIS)

    Deflandre, Jean-Pierre; Heidmann, Jean-Claude; Vially, Roland; Duflot, Sylvie; Lions, Renaud; Speirs, Julie; Bauquis, Pierre-Rene; Brunelle, Nathalie

    2015-01-01

    A first article proposes an overview of gas and oil resources with respect to their geological context. The authors address the origins of hydrocarbons, their underground migration and possible trapping, thus scanning the whole spectrum of conventional and non conventional resources. A second article, signed by representatives of companies working on shale gas in Europe as well as in the USA, examines whether the development of shale gases, if it ever emerges in Europe, will be the same as it is in the USA. They notably outline differences regarding several legal aspects on land property and on the environment. Based on a study on shale supply chain which identified costs, needed skills, existing capabilities, and recommendations for closing identified gaps, the third article discusses the perspective and opportunity of a possible development of shale gas in the UK. The fourth article discusses the impacts of the exploitation of source rock oils and gases on the American and World economies, and the fifth one discusses the perspectives for the petrochemicals and refining industries in a context of development of shale gases and oils in the USA, of an over-capacity situation for the refining industry, of decline of the European oil product market, and of competition with new polymer production capacities (notably in the Middle East where ethane extracted from natural gas is available in large quantities and at very low prices)

  14. Power Quality Improvement Of Grid Integrated Type I Wind Turbine Generation System Operating as DSTATCOM by d-q Control Method

    Directory of Open Access Journals (Sweden)

    S V S Phani Kumar.Ch

    2016-06-01

    Full Text Available In recent years with the excessive consumption of electrical energy, the incongruity between generation and demand, the irrational structure of World’s energy as well as the environmental pollution have become progressively more evident. It has become crucial for ecological development to reduce the consumption of conventional energy and to enhance the development and utilization of renewable energy. Wind energy and Solar are unlimited supply of renewable energy and it has no pollution. But this concept suffer from the power quality issues from grid and generator side, this paper presents a control strategy for achieving maximum benefits from these grid-interfacing inverter when installed in 3-phase 4-wire distribution systems. The inverter can be controlled to perform as a multi-function device by incorporating active power filter functionality. The inverter can thus be utilized as: 1 power converter to inject power generated from RES to the grid and 2 shunt APF (Active Power Filter to compensate current unbalance, load current harmonics, load reactive power demand and load neutral current. All of these functions may be accomplished either individually or simultaneously. With such a control, the combination of grid-interfacing inverter and the 3-phase 4-wire linear/non-linear unbalanced load at point of common coupling appears as balanced linear load to the grid. The Paper propose design of 500kW Type I Wind Generation System 250kW each with Four Leg Inverter Controlled by d-q technique operated as DSTATCOM connected to 415V 4 wire Grid and also the results are compared with conventional Unit Vector Control. The proposed d-q method reduces the %THD of system to 1.97% from 24.12% where Unit Vector Control is of 3.94% which was on higher side , this is simulated in MATLAB/SIMULINK.

  15. Conventional resin cation exchangers versus EDI for CACE measurement in power plants. Feasibility and practical field results

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Manuel [Swan Systeme AG, Hinwil (Switzerland)

    2017-10-15

    The conductivity measurement after a cation exchanger in power plants with steam turbines was introduced soon after 1950 by Larson and Lane. Due to the simple measuring principle, the sensitivity to ionic contaminations and to its high reliability, the conductivity measurement after a cation exchanger (CACE) has become the most commonly used online analytical method in power plants with steam generators. Swan has investigated electro deionisation (EDI) as substitution of the conventional cation exchange resin and has developed a new conductivity instrument using this principle. This paper provides a description of the conventional method for cation conductivity measurements as well as of the new AMI CACE using EDI method.

  16. Conventional resin cation exchangers versus EDI for CACE measurement in power plants. Feasibility and practical field results

    International Nuclear Information System (INIS)

    Sigrist, Manuel

    2017-01-01

    The conductivity measurement after a cation exchanger in power plants with steam turbines was introduced soon after 1950 by Larson and Lane. Due to the simple measuring principle, the sensitivity to ionic contaminations and to its high reliability, the conductivity measurement after a cation exchanger (CACE) has become the most commonly used online analytical method in power plants with steam generators. Swan has investigated electro deionisation (EDI) as substitution of the conventional cation exchange resin and has developed a new conductivity instrument using this principle. This paper provides a description of the conventional method for cation conductivity measurements as well as of the new AMI CACE using EDI method.

  17. Non-HIV Pneumocystis pneumonia: do conventional community-acquired pneumonia guidelines under estimate its severity?

    Science.gov (United States)

    Asai, Nobuhiro; Motojima, Shinji; Ohkuni, Yoshihiro; Matsunuma, Ryo; Nakasima, Kei; Iwasaki, Takuya; Nakashita, Tamao; Otsuka, Yoshihito; Kaneko, Norihiro

    2012-06-11

    Non-HIV Pneumocystis pneumonia (PCP) can occur in immunosuppressed patients having malignancy or on immunosuppressive agents. To classify severity, the A-DROP scale proposed by the Japanese Respiratory Society (JRS), the CURB-65 score of the British Respiratory Society (BTS) and the Pneumonia Severity Index (PSI) of the Infectious Diseases Society of America (IDSA) are widely used in patients with community-acquired pneumonia (CAP) in Japan. To evaluate how correctly these conventional prognostic guidelines for CAP reflect the severity of non-HIV PCP, we retrospectively analyzed 21 patients with non-HIV PCP. A total of 21 patients were diagnosed by conventional staining and polymerase chain reaction (PCR) for respiratory samples with chest x-ray and computed tomography (CT) findings. We compared the severity of 21 patients with PCP classified by A-DROP, CURB-65, and PSI. Also, patients' characteristics, clinical pictures, laboratory results at first visit or admission and intervals from diagnosis to start of specific-PCP therapy were evaluated in both survivor and non-survivor groups. Based on A-DROP, 18 patients were classified as mild or moderate; respiratory failure developed in 15 of these 18 (83.3%), and 7/15 (46.7%) died. Based on CURB-65, 19 patients were classified as mild or moderate; respiratory failure developed in 16/19 (84.2%), and 8 of the 16 (50%) died. In contrast, PSI classified 14 as severe or extremely severe; all of the 14 (100%) developed respiratory failure and 8/14 (57.1%) died. There were no significant differences in laboratory results in these groups. The time between the initial visit and diagnosis, and the time between the initial visit and starting of specific-PCP therapy were statistically shorter in the survivor group than in the non-survivor group. Conventional prognostic guidelines for CAP could underestimate the severity of non-HIV PCP, resulting in a therapeutic delay resulting in high mortality. The most important factor to

  18. Quasidynamic emergency analysis, identification and control of power system frequency perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Jovanovic, S M [Nikola Tesla Institute, Belgrade (YU)

    1990-07-01

    There are several possible operating states of a power system. These are the normal operating state (both secure and insecure), the emergency state, the extreme emergency state and the restorative state. The system enters the emergency operating state if any of the operating constraints are violated. Emergency analysis attempts to compute in real time the violations of these constraints and the new (successive) disturbances which arise from the initial ones. The paper presents a quasidynamic approach to emergency state analysis, identification and control of power system frequency perturbations. A quasidynamic model is derived by simplifying the conventional long-term dynamics model of power systems in the time interval 0-5 s. The quasidynamic model is algebraic in nature, but the time variable t is incorporated into the model and is used to describe the part of the system dynamics that is of interest in the specified time interval. The paper proposes an on-line computer emergency control strategy based on the above quasidynamic model. Finally, a numerical example is given for the Yugoslav power system. (author).

  19. The Optimal Dispatch of a Power System Containing Virtual Power Plants under Fog and Haze Weather

    Directory of Open Access Journals (Sweden)

    Yajing Gao

    2016-01-01

    Full Text Available With the growing influence of fog and haze (F-H weather and the rapid development of distributed energy resources (DERs and smart grids, the concept of the virtual power plant (VPP employed in this study would help to solve the dispatch problem caused by multiple DERs connected to the power grid. The effects of F-H weather on photovoltaic output forecast, load forecast and power system dispatch are discussed according to real case data. The wavelet neural network (WNN model was employed to predict photovoltaic output and load, considering F-H weather, based on the idea of “similar days of F-H”. The multi-objective optimal dispatch model of a power system adopted in this paper contains several VPPs and conventional power plants, under F-H weather, and the mixed integer linear programming (MILP and the Yalmip toolbox of MATLAB were adopted to solve the dispatch model. The analysis of the results from a case study proves the validity and feasibility of the model and the algorithms.

  20. Use of non-conventional yeast improves the wine aroma profile of Ribolla Gialla

    NARCIS (Netherlands)

    Dashko, Sofia; Zhou, Nerve; Tinta, Tinkara; Sivilotti, Paolo; Lemut, Melita Sternad; Trost, Kajetan; Gamero, Amparo; Boekhout, Teun; Butinar, Lorena; Vrhovsek, Urska; Piskur, Jure

    Consumer wine preferences are changing rapidly towards exotic flavours and tastes. In this work, we tested five non-conventional yeast strains for their potential to improve Ribolla Gialla wine quality. These strains were previously selected from numerous yeasts interesting as food production

  1. Power system security enhancement through direct non-disruptive load control

    Science.gov (United States)

    Ramanathan, Badri Narayanan

    The transition to a competitive market structure raises significant concerns regarding reliability of the power grid. A need to build tools for security assessment that produce operating limit boundaries for both static and dynamic contingencies is recognized. Besides, an increase in overall uncertainty in operating conditions makes corrective actions at times ineffective leaving the system vulnerable to instability. The tools that are in place for stability enhancement are mostly corrective and suffer from lack of robustness to operating condition changes. They often pose serious coordination challenges. With deregulation, there have also been ownership and responsibility issues associated with stability controls. However, the changing utility business model and the developments in enabling technologies such as two-way communication, metering, and control open up several new possibilities for power system security enhancement. This research proposes preventive modulation of selected loads through direct control for power system security enhancement. Two main contributions of this research are the following: development of an analysis framework and two conceptually different analysis approaches for load modulation to enhance oscillatory stability, and the development and study of algorithms for real-time modulation of thermostatic loads. The underlying analysis framework is based on the Structured Singular Value (SSV or mu) theory. Based on the above framework, two fundamentally different approaches towards analysis of the amount of load modulation for desired stability performance have been developed. Both the approaches have been tested on two different test systems: CIGRE Nordic test system and an equivalent of the Western Electric Coordinating Council test system. This research also develops algorithms for real-time modulation of thermostatic loads that use the results of the analysis. In line with some recent load management programs executed by utilities, two

  2. Approach to improve the axial power distribution for the application of a core protection system

    International Nuclear Information System (INIS)

    Koo, Bon Seung; Cho, Jin Young; Song, Jae Seung; Lee, Chung Chan

    2008-01-01

    A Core Protection Calculator System (CPCS) is a digital computer based on a safety system for generating trip signals based on a calculation of the Departure from Nucleate Boiling Ratio (DNBR) and the Local Power Density (LPD) by using several on-line measured system parameters including 3-level ex-core detector signals. A few approaches to improve the axial power distribution for the application of a core protection system were performed. For the Yonggwang unit 3 (cycle 1), axial power distributions were synthesized by applying the cubic spline method and compared with the neutronics code results. Several new cubic spline function sets were generated for the drastically distorted axial shapes for a 3-level ex-core detector system. In addition, synthesized axial shapes with a 5-level ex-core detector signals were compared with the conventional 3-level detector results. It demonstrates that the newly generated function sets appear to be better than that of the conventional CPC from the aspect of an axial power synthesis, particularly for the heavily distorted shapes. Moreover, synthesis of an axial power distribution using 5-level ex-core detector signals appears to be better than that of the 3-level ex-core detector signals. From the above results, improvement of the thermal margin is expected because of an uncertainty decreasing a core protection system. (authors)

  3. Robust PID based power system stabiliser: Design and real-time implementation

    Energy Technology Data Exchange (ETDEWEB)

    Bevrani, Hassan [Department of Electrical and Computer Eng., University of Kurdistan, Sanandaj (Iran, Islamic Republic of); Hiyama, Takashi [Department of Electrical and Computer Eng., Kumamoto University, Kumamoto (Japan); Bevrani, Hossein [Department of Statistics, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2011-02-15

    This paper addresses a new robust control strategy to synthesis of robust proportional-integral-derivative (PID) based power system stabilisers (PSS). The PID based PSS design problem is reduced to find an optimal gain vector via an H{infinity} static output feedback control (H{infinity}-SOF) technique, and the solution is easily carried out using a developed iterative linear matrix inequalities algorithm. To illustrate the developed approach, a real-time experiment has been performed for a longitudinal four-machine infinite-bus system using the Analog Power System Simulator at the Research Laboratory of the Kyushu Electric Power Company. The results of the proposed control strategy are compared with full-order H{infinity} and conventional PSS designs. The robust PSS is shown to maintain the robust performance and minimise the effect of disturbances properly. (author)

  4. Non-Powered Spectrophotometry for Lighting

    Data.gov (United States)

    National Aeronautics and Space Administration — This process improvement innovation would like to suggest a non-powered method and tool set that can be developed to assist crewmembers and ground support teams with...

  5. Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

    Science.gov (United States)

    Scheidegger, Brianne, T.; Burke, Kenneth A.; Jakupca, Ian J.

    2012-01-01

    This paper describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the rover s hotel loads. This work represents the first attempt at a ground demonstration of this new technology aboard a mobile test platform. Development and demonstration were supported by the Office of the Chief Technologist s Space Power Systems Project and the Advanced Exploration System Modular Power Systems Project.

  6. Impact of high level penetration of Wind Turbines on Power System Transient Stability

    DEFF Research Database (Denmark)

    Kalogiannis, Theodoros; Llano, Enrique Muller; Hoseinzadeh, Bakhtyar

    2015-01-01

    generators differ from the conventional ones in their inertial contribution to the grid, therefore, in most cases the ability of the system to maintain a stable operation is declined. To investigate this, two standard models are designed in PowerFactory software. The first is used to characterize system...

  7. Modular simulation of a hybrid power system with diesel, photovoltaic inverter and wind turbine generation

    Directory of Open Access Journals (Sweden)

    Klimis Ch. Karasavvas

    2008-05-01

    Full Text Available The dynamic behavior and stability of an isolated electric power system, fed by a conventional energy plant and a re-newable energy system, is presented in this paper. Matlab/Simulink is the used software for simulating the whole system.

  8. Performance characterization of a power generation unit–organic Rankine cycle system based on the efficiencies of the system components

    International Nuclear Information System (INIS)

    Knizley, Alta; Mago, Pedro J.; Tobermann, James; Warren, Harrison R.

    2015-01-01

    Highlights: • Use of waste heat from a power generation unit to generate electricity is explored. • An organic Rankine cycle is used to recover the waste heat. • The system may lower cost, primary energy consumption, and carbon dioxide emission. • A parameter was established to show when the proposed system would provide savings. • The proposed system was evaluated in different locations in the US. - Abstract: This paper analyzes the potential of using the waste heat from a power generation unit to generate additional electricity using an organic Rankine cycle to reduce operational cost, primary energy consumption, and carbon dioxide emissions in different locations in the U.S. The power generation unit–organic Rankine cycle system is compared with a conventional system in terms of operational cost, primary energy consumption, and carbon dioxide emissions reduction. A parameter (R_m_i_n), which is based on system efficiencies, is established to determine when the proposed power generation unit–organic Rankine cycle system would potentially provide savings versus the conventional system in which electricity is purchased from the utility grid. The effect on the R_m_i_n parameter with variation of each system efficiency is also analyzed in this paper. Results indicated that savings in one parameter, such as primary energy consumption, did not imply savings in the other two parameters. Savings in the three parameters (operational cost, primary energy consumption, and carbon dioxide emissions) varied widely based on location due to prices of natural gas and electricity, source-to-site conversion factors, and carbon dioxide emissions conversion factors for electricity and natural gas. Variations in each system efficiency affected R_m_i_n, but varying the power generation unit efficiency had the most dramatic effect in the overall savings potential from the proposed system.

  9. Evaluation of hybrid power system alternatives: a case study

    International Nuclear Information System (INIS)

    Rosenthal, Andrew L.

    1999-01-01

    Pursuant to executive and statutory policies, the National Park Service (NPS) has been evaluating the use of photovoltaic (PV) hybrid power systems, for many of its remote, off-grid areas. This paper reports the results of a detailed technical and economic evaluation for one such area: the Needles District of Canyonlands National Park. The study evaluates the presented power systems and five alternative power generation configurations, four of which utilise PV. Projections are provided for the generator run-time and fuel use associated with each configuration as well as all initial and future costs. Included in the study are specific recommendations for energy efficiency improvements at the site. Results show that the generation systems presently in use, two full-time diesel generators, has the lowest conventional 20-year life cycle costs (LCC) of the six systems evaluated. However, when emissions costs are included (per NPS guidelines), several of the PV hybrid alternatives attain a lower LCC than the diesel-only systems. General discussion of the effects of initial versus future costs of PV hybrids as they compare with engine generator system is presented. (Author)

  10. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is a hydraulic, battery, or mechanically powered device, either fixed or mobile, used to lift and transport a...

  11. Automatic generation control of multi-area power systems with diverse energy sources using Teaching Learning Based Optimization algorithm

    Directory of Open Access Journals (Sweden)

    Rabindra Kumar Sahu

    2016-03-01

    Full Text Available This paper presents the design and analysis of Proportional-Integral-Double Derivative (PIDD controller for Automatic Generation Control (AGC of multi-area power systems with diverse energy sources using Teaching Learning Based Optimization (TLBO algorithm. At first, a two-area reheat thermal power system with appropriate Generation Rate Constraint (GRC is considered. The design problem is formulated as an optimization problem and TLBO is employed to optimize the parameters of the PIDD controller. The superiority of the proposed TLBO based PIDD controller has been demonstrated by comparing the results with recently published optimization technique such as hybrid Firefly Algorithm and Pattern Search (hFA-PS, Firefly Algorithm (FA, Bacteria Foraging Optimization Algorithm (BFOA, Genetic Algorithm (GA and conventional Ziegler Nichols (ZN for the same interconnected power system. Also, the proposed approach has been extended to two-area power system with diverse sources of generation like thermal, hydro, wind and diesel units. The system model includes boiler dynamics, GRC and Governor Dead Band (GDB non-linearity. It is observed from simulation results that the performance of the proposed approach provides better dynamic responses by comparing the results with recently published in the literature. Further, the study is extended to a three unequal-area thermal power system with different controllers in each area and the results are compared with published FA optimized PID controller for the same system under study. Finally, sensitivity analysis is performed by varying the system parameters and operating load conditions in the range of ±25% from their nominal values to test the robustness.

  12. Advanced power supply and distribution systems for Columbus

    Science.gov (United States)

    Eggers, Gert

    1988-01-01

    The paper describes power supply and distribution systems to be used on unmanned/man-tended Columbus elements, capable of supplying 10 kW to 30 kW to a variety of users in low earth orbits (LEO's). For the definition of the Electrical Power System (EPS) challenging requirements as the provision of high power levels under hard LEO conditions, maintainability, commonality etc. are to be taken into account. These requirements are to be seen in conjunction with the Columbus IOC (initial operational capability) scenario stipulating that EPS hardware shall be used on the Polar Platform, the Pressurized Module attached to the U.S. Space Station and the Man-Tended Free Flier. According to the availability of European technologies, the baseline in the power generation area is a photovoltaic system which provides three regulated main buses (150 V d.c.) to the users. In order to maintain power supply during eclipse phases, nickel hydrogen batteries will be used for energy storage purposes with nickel cadmium as back-up solution. The power distribution system needs special attention. Due to the elevated voltage levels mechanical switch gear cannot be used any longer. It is to be replaced by solid state power controllers (SSPC). Because these devices show a totally different behaviour with regard to conventional relay contacts, new approaches in the area of switching and protection are necessary. In view of the crucial role of this new technology for the realization of medium voltage d.c. systems, it is of great importance for Columbus and, hence will receive adequate consideration in the paper. In order to cater for effective management and control of the power supply and distribution hardware, a so called power system internal data processing assembly (PINDAP) has been introduced in the EPS. PINDAP is the key to reduced dependence on ground stations (alleviated ground support requirements); it keeps crew involvement in the EPS control process to as minimum and provides

  13. On energy efficient power allocation for power-constrained systems

    KAUST Repository

    Sboui, Lokman

    2014-09-01

    Recently, the energy efficiency (EE) has become an important factor when designing new wireless communication systems. Due to economic and environmental challenges, new trends and efforts are oriented toward “green” communication especially for energy-constrained applications such as wireless sensors network and cognitive radio. To this end, we analyze the power allocation scheme that maximizes the EE defined as rate over the total power including circuit power. We derive an explicit expression of the optimal power with instantaneous channel gain based on EE criterion. We show that the relation between the EE and the spectral efficiency (SE) when the optimal power is adopted is strictly increasing in contrast with the SE-EE trade-off discussed in the literature. We also solve a non-convex problem and compute explicitly the optimal power for ergodic EE under either a peak or an average power constraint. When the instantaneous channel is not available, we provide the optimal power equation and compute simple sub-optimal power. In the numerical results, we show that the sup-optimal solution is very close to the optimal solution. In addition, we show that the absence of the channel state information (CSI) only affects the EE and the SE performances at high power regime compared to the full CSI case.

  14. Coordinated parallel and series flexible AC transmission systems (FACTS) to support a power grid with a large amount of wind power

    Energy Technology Data Exchange (ETDEWEB)

    Mora-Cantallops, Marcal; Gomis-Bellmunt, Oriol; Sumper, Andreas; Rull-Duran, Joan [Univ. Politecnica de Catalunya, Barcelona (ES). Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC)

    2009-07-01

    Wind power constitutes one of the more viable alternatives to conventional power generation technology. In the previous years, wind power penetration on electric grids has grown notably, and has brought several new issues related to its integration into power grids. Flexible AC Transmission Systems (FACTS) installed in the right place and controlled conveniently are able to mitigate and solve many of these issues. In the present work, a STATCOM and a SSSC are used coordinately to fully support an electric grid. Simulations include normal and fault operation. (orig.)

  15. Maximum Power Point Tracking of Photovoltaic System for Traffic Light Application

    Directory of Open Access Journals (Sweden)

    Riza Muhida

    2013-07-01

    Full Text Available Photovoltaic traffic light system is a significant application of renewable energy source. The development of the system is an alternative effort of local authority to reduce expenditure for paying fees to power supplier which the power comes from conventional energy source. Since photovoltaic (PV modules still have relatively low conversion efficiency, an alternative control of maximum power point tracking (MPPT method is applied to the traffic light system. MPPT is intended to catch up the maximum power at daytime in order to charge the battery at the maximum rate in which the power from the battery is intended to be used at night time or cloudy day. MPPT is actually a DC-DC converter that can step up or down voltage in order to achieve the maximum power using Pulse Width Modulation (PWM control. From experiment, we obtained the voltage of operation using MPPT is at 16.454 V, this value has error of 2.6%, if we compared with maximum power point voltage of PV module that is 16.9 V. Based on this result it can be said that this MPPT control works successfully to deliver the power from PV module to battery maximally.

  16. Power MOSFET-diode-based limiter for high-frequency ultrasound systems.

    Science.gov (United States)

    Choi, Hojong; Kim, Min Gon; Cummins, Thomas M; Hwang, Jae Youn; Shung, K Kirk

    2014-10-01

    The purpose of the limiter circuits used in the ultrasound imaging systems is to pass low-voltage echo signals generated by ultrasonic transducers while preventing high-voltage short pulses transmitted by pulsers from damaging front-end circuits. Resistor-diode-based limiters (a 50 Ω resistor with a single cross-coupled diode pair) have been widely used in pulse-echo measurement and imaging system applications due to their low cost and simple architecture. However, resistor-diode-based limiters may not be suited for high-frequency ultrasound transducer applications since they produce large signal conduction losses at higher frequencies. Therefore, we propose a new limiter architecture utilizing power MOSFETs, which we call a power MOSFET-diode-based limiter. The performance of a power MOSFET-diode-based limiter was evaluated with respect to insertion loss (IL), total harmonic distortion (THD), and response time (RT). We compared these results with those of three other conventional limiter designs and showed that the power MOSFET-diode-based limiter offers the lowest IL (-1.33 dB) and fastest RT (0.10 µs) with the lowest suppressed output voltage (3.47 Vp-p) among all the limiters at 70 MHz. A pulse-echo test was performed to determine how the new limiter affected the sensitivity and bandwidth of the transducer. We found that the sensitivity and bandwidth of the transducer were 130% and 129% greater, respectively, when combined with the new power MOSFET-diode-based limiter versus the resistor-diode-based limiter. Therefore, these results demonstrate that the power MOSFET-diode-based limiter is capable of producing lower signal attenuation than the three conventional limiter designs at higher frequency operation. © The Author(s) 2014.

  17. Standard Guide for Specifying Thermal Performance of Geothermal Power Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers power plant performance terms and criteria for use in evaluation and comparison of geothermal energy conversion and power generation systems. The special nature of these geothermal systems makes performance criteria commonly used to evaluate conventional fossil fuel-fired systems of limited value. This guide identifies the limitations of the less useful criteria and defines an equitable basis for measuring the quality of differing thermal cycles and plant equipment for geothermal resources. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Proceedings of the 2009 CIGRE Canada conference on power systems : innovation and renewal : building the new power system

    International Nuclear Information System (INIS)

    2009-01-01

    The Conseil International des Grands Reseaux Electriques (CIGRE) is the International Council on Large Electric Systems. It promotes technical, economic and environmental developments in electricity transmission and generation. CIGRE Canada is the Canadian National Committee which fosters the participation of Canadian members in CIGRE activities. CIGRE Canada organizes an annual conference that provides a forum for power system engineers, decision makers,economists, and academics to discuss technological developments in electrical power systems. The presentations at this conference addressed issues regarding the use of renewable energy sources in power transmission and distribution systems, with particular reference to control and protection; HVDC and MVDC; modelling tools; interface technologies; and reduced carbon generation and sustainability. The use of active distribution systems was also discussed in terms of future trends; the role of information technology and communications; and the role of energy storage. The session on smart grids addressed issues such as power utility perspectives; sensing, measurements and controls; advanced interfaces and decision support systems; open-architecture; distributed energy resources; and regulatory issues. Issues concerning the interconnection of non traditional energy sources to the power systems were also discussed along with recent research initiatives related to renewable energy source development. The sessions were entitled: smart grids; distributed energy resources; wind and solar PV; AC systems and HV lines; wide area measurements; power system operation and control; modelling and analysis; substation automation; and HVDC and facts. The conference featured 66 presentations, of which 35 have been catalogued separately for inclusion in this database

  19. Graphical analysis of power systems for mobile robotics

    Science.gov (United States)

    Raade, Justin William

    The field of mobile robotics places stringent demands on the power system. Energetic autonomy, or the ability to function for a useful operation time independent of any tether, refueling, or recharging, is a driving force in a robot designed for a field application. The focus of this dissertation is the development of two graphical analysis tools, namely Ragone plots and optimal hybridization plots, for the design of human scale mobile robotic power systems. These tools contribute to the intuitive understanding of the performance of a power system and expand the toolbox of the design engineer. Ragone plots are useful for graphically comparing the merits of different power systems for a wide range of operation times. They plot the specific power versus the specific energy of a system on logarithmic scales. The driving equations in the creation of a Ragone plot are derived in terms of several important system parameters. Trends at extreme operation times (both very short and very long) are examined. Ragone plot analysis is applied to the design of several power systems for high-power human exoskeletons. Power systems examined include a monopropellant-powered free piston hydraulic pump, a gasoline-powered internal combustion engine with hydraulic actuators, and a fuel cell with electric actuators. Hybrid power systems consist of two or more distinct energy sources that are used together to meet a single load. They can often outperform non-hybrid power systems in low duty-cycle applications or those with widely varying load profiles and long operation times. Two types of energy sources are defined: engine-like and capacitive. The hybridization rules for different combinations of energy sources are derived using graphical plots of hybrid power system mass versus the primary system power. Optimal hybridization analysis is applied to several power systems for low-power human exoskeletons. Hybrid power systems examined include a fuel cell and a solar panel coupled with

  20. Seismic analysis of nuclear power plants

    International Nuclear Information System (INIS)

    Halbritter, A.L.

    1984-01-01

    Nuclear Power Plants require exceptional safety guarantees which are reflected in a rigorous control of the employed materials, advanced construction technology, sophisticated methods of analysis and consideration of non conventional load cases such as the earthquake loading. In this paper, the current procedures used in the seismic analysis of Nuclear Power Plants are presented. The seismic analysis of the structures has two objectives: the determination of forces in the structure in order to design it against earthquakes and the generation of floor response spectra to be used in the design of mechanical and electrical components and piping systems. (Author) [pt

  1. Electric power systems

    CERN Document Server

    Weedy, B M; Jenkins, N; Ekanayake, J B; Strbac, G

    2012-01-01

    The definitive textbook for Power Systems students, providing a grounding in essential power system theory while also focusing on practical power engineering applications. Electric Power Systems has been an essential book in power systems engineering for over thirty years. Bringing the content firmly up-to-date whilst still retaining the flavour of Weedy's extremely popular original, this Fifth Edition has been revised by experts Nick Jenkins, Janaka Ekanayake and Goran Strbac. This wide-ranging text still covers all of the fundamental power systems subjects but is now e

  2. A comparative analysis of the domestic and foreign licensing processes for power and non-power reactors

    International Nuclear Information System (INIS)

    Joe, J. C.; Youn, Y. K.; Kim, W. S.; Kim, H. J.

    2003-01-01

    The System-integrated Modular Advanced Reactor (SMART), a small to medium sized integral type Pressurized Water Reactor (PWR) has been developed in Korea. Now, SMART-P, a 1/5 scaled-down of the SMART, is being developed for the purpose of demonstrating the safety and performance of SMART design. The SMART-P is a first-of-a-kind reactor which is utilized for the research and development of a power reactor. Since the licensing process of such a reactor is not clearly specified in the current Atomic Energy Act, a comparative survey and analysis of domestic and foreign licensing processes for power and non-power reactors has been carried out to develop the rationale and technical basis for establishing the licensing process of such a reactor. The domestic and foreign licensing processes of power and non-power reactors have been surveyed and compared, including those of the U.S.A., Japan, France, U.K., Canada, and IAEA. The general trends in nuclear reactor classification, licensing procedures, regulatory technical requirements, and other licensing requirements and regulations have been investigated. The results of this study will be used as the rationale and technical basis for establishing the licensing process of reactors at development stage such as SMART-P

  3. The role of co-located storage for wind power producers in conventional electricity markets

    KAUST Repository

    Bitar, E.

    2011-06-01

    In this paper we study the problem of optimizing contract offerings for an independent wind power producer (WPP) participating in conventional day-ahead forward electricity markets for energy. As wind power is an inherently variable source of energy and is difficult to predict, we explore the extent to which co-located energy storage can be used to improve expected profit and mitigate the the financial risk associated with shorting on the offered contracts. Using a simple stochastic model for wind power production and a model for the electricity market, we show that the problem of determining optimal contract offerings for a WPP with co-located energy storage can be solved using convex programming.

  4. Performance of the ramping power supplies for the APS booster synchrotron

    International Nuclear Information System (INIS)

    Carwardine, J.A.; Milton, S.V.; McGhee, D.G.

    1995-01-01

    The Advanced Photon Source (APS) booster ramp cycle is completed within 250ms and repeated at 2Hz. Separate phase-controlled power supplies deliver current to each of the dipole, quadrupole, and sextupole magnet families. Tracking requirements are particularly challenging because of the fast (non-resonant) ramp. In order to meet the requirements, both conventional regulation and cycle-to-cycle adaptation are used. The power supply system and its performance are described

  5. Wind power and market power in competitive markets

    International Nuclear Information System (INIS)

    Twomey, Paul; Neuhoff, Karsten

    2010-01-01

    Average market prices for intermittent generation technologies are lower than for conventional generation. This has a technical reason but can be exaggerated in the presence of market power. When there is much wind smaller amounts of conventional generation technologies are required, and prices are lower, while at times of little wind prices are higher. This effect reflects the value of different generation technologies to the system. But under conditions of market power, conventional generators with market power can further depress the prices if they have to buy back energy at times of large wind output and can increase prices if they have to sell additional power at times of little wind output. This greatly exaggerates the effect. Forward contracting does not reduce the effect. An important consequence is that allowing market power profit margins as a support mechanism for generation capacity investment is not a technologically neutral policy.

  6. International comparison of requirements for connection of wind turbines to power systems

    Energy Technology Data Exchange (ETDEWEB)

    Jauch, C. [Risoe National Lab., Roskilde (Denmark). Dept. of Wind Energy; Matevosyan, J.; Ackermann, T. [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Electrical Engineering; Bolik, S. [Vestas Wind Systems A/S, Ringkoebing (Denmark)

    2005-07-01

    Power production from wind turbines has increased considerably during the last decade. Therefore today's wind turbines, which are typically set up in wind farms, have a significant influence on the operation of power systems. The efficient and secure operation of power systems is supported by grid codes, which are sets of requirements for all network users (suppliers, customers, etc.). In Europe, several transmission network operators have introduced special grid connection requirements for wind farms. These requirements are mainly based on existing grid codes, initially written for conventional power plants usually equipped with synchronous generators. This article presents a comparison of grid connection requirements for wind farms issued, or proposed as a draft, by transmission network operators in Denmark, Sweden, Germany, Scotland and Ireland. (author)

  7. Discrete event simulation versus conventional system reliability analysis approaches

    DEFF Research Database (Denmark)

    Kozine, Igor

    2010-01-01

    Discrete Event Simulation (DES) environments are rapidly developing and appear to be promising tools for building reliability and risk analysis models of safety-critical systems and human operators. If properly developed, they are an alternative to the conventional human reliability analysis models...... and systems analysis methods such as fault and event trees and Bayesian networks. As one part, the paper describes briefly the author’s experience in applying DES models to the analysis of safety-critical systems in different domains. The other part of the paper is devoted to comparing conventional approaches...

  8. Impacts of Demand-Side Management on Electrical Power Systems: A Review

    Directory of Open Access Journals (Sweden)

    Hussein Jumma Jabir

    2018-04-01

    Full Text Available Electricity demand has grown over the past few years and will continue to grow in the future. The increase in electricity demand is mainly due to industrialization and the shift from a conventional to a smart-grid paradigm. The number of microgrids, renewable energy sources, plug-in electric vehicles and energy storage systems have also risen in recent years. As a result, future electricity grids have to be revamped and adapt to increasing load levels. Thus, new complications associated with future electrical power systems and technologies must be considered. Demand-side management (DSM programs offer promising solutions to these issues and can considerably improve the reliability and financial performances of electrical power systems. This paper presents a review of various initiatives, techniques, impacts and recent developments of the DSM of electrical power systems. The potential benefits derived by implementing DSM in electrical power networks are presented. An extensive literature survey on the impacts of DSM on the reliability of electrical power systems is also provided for the first time. The research gaps within the broad field of DSM are also identified to provide directions for future work.

  9. GT-MHR power conversion system: Design status and technical issues

    International Nuclear Information System (INIS)

    Etzel, K.; Baccaglini, G.; Schwartz, A.; Hillman, S.; Mathis, D.

    1994-12-01

    The Modular Helium Reactor (MHR) builds on 30 years of international gas-cooled reactor experience utilizing the unique properties of helium gas coolant, graphite moderator and coated particle fuel. To efficiently utilize the high temperature potential of the MHR, an innovative power conversion system has been developed featuring an intercooled and recuperated gas turbine. The gas turbine replaces a conventional steam turbine and its many auxiliary components. The Power Conversion System converts the thermal energy of the helium directly into electrical energy utilizing a closed Brayton cycle. The Power Conversion System draws on even more years of experience than the MHR: the world's first closed-cycle plant, fossil fired and utilizing air as working fluid, started operation in Switzerland in 1939. Shortly thereafter, in 1945, the coupling of a closed-cycle plant to a nuclear heat generation system was conceived. Directly coupling the closed-cycle gas turbine concept to a modern, passively safe nuclear reactor opens a new chapter in power generation technology and brings with it various design challenges. Some of these challenges are associated with the direct coupling of the Power Conversion System to a nuclear reactor. Since the primary coolant is also the working fluid, the Power Conversion System has to be designed for reactor radionuclide plateout. As a result, issues like component maintainability and replaceability, and fission product effects on materials must be addressed. Other issues concern the integration of the Power Conversion System components into a single vessel. These issues include the selection of key technologies for the power conversion components such as submerged generator, magnetic bearings, seals, compact heat exchangers, and the overall system layout

  10. A modular approach to modeling power plant systems

    International Nuclear Information System (INIS)

    Yee, N.S.

    1990-01-01

    This paper reports on power plants which are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems, dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. A simulation can be used to answer the what if questions that are asked when replacing components, changing operational procedures, or training operators. While there are many applications for the simulation of power plant components and systems, its use is often discouraged because it can be difficult and expensive. Power plant engineering is itself a multi-disciplinary field involving fluid mechanics, heat transfer, thermodynamics, chemical engineering, nuclear engineering, and electrical engineering. Simulation requires, in addition, knowledge in model formulation, computer programming and numerical solution of differential equations

  11. Design Criteria for Future Fuels and Related Power Systems Addressing the Impacts of Non-CO2 Pollutants on Human Health and Climate Change.

    Science.gov (United States)

    Schauer, James Jay

    2015-01-01

    Concerns over the economics, supply chain, and emissions of greenhouse gases associated with the wide use of fossil fuels have led to increasing interest in developing alternative and renewable fuels for stationary power generation and transportation systems. Although there is considerable uncertainty regarding the economic and environmental impacts of alternative and renewable fuels, there is a great need for assessment of potential and emerging fuels to guide research priorities and infrastructure investment. Likewise, there is a great need to identify potential unintended adverse impacts of new fuels and related power systems before they are widely adopted. Historically, the environmental impacts of emerging fuels and power systems have largely focused on carbon dioxide emissions, often called the carbon footprint, which is used to assess impacts on climate change. Such assessments largely ignore the large impacts of emissions of other air pollutants. Given the potential changes in emissions of air pollutants associated with the large-scale use of new and emerging fuels and power systems, there is a great need to better guide efforts to develop new fuels and power systems that can avoid unexpected adverse impacts on the environment and human health. This review covers the nature of emissions, including the key components and impacts from the use of fuels, and the design criteria for future fuels and associated power systems to assure that the non-CO2 adverse impacts of stationary power generation and transportation are minimized.

  12. Optimal design of emission control systems for a fossil power plants

    International Nuclear Information System (INIS)

    Sfez, D.; Muginstein, A.; Naeh, Y.

    1998-01-01

    The detrimental environmental effects of pulverized coal power stations are enforcing the installation of additional emission control equipment. Utilization of this equipment significantly increases the installation and operation costs of the power station, which raises the cost of the electricity generated by this power station. Focusing on the flue gas cleaning equipment can substantially reduce the electricity-generating rate. Improving the equipment design is the only available way to reduce the flue gas cleaning costs, without affecting the power station flexibility and availability. An optimal design is defined as the one achieving the least expensive cleaning system (capital and operating costs) while maintaining the original power station operation flexibility (coal variety and partial load performances). Two main changes in the conventional design need to be carried out in order to reach the above-mentioned optimized design. The first modification is to integrate the ESP and FGD at the design criteria stage while considering the influence of each piece of equipment on the other. The second stage is to set one common best efficiency design point to the ESP and the FGD together. Achieving this one common best efficiency point requires some equipment addition and modifications to the conventional ESP and FGD systems. The technology involved in this modification is available and is well proven in operation. Using this technology with the optimal design concept will lead to a significant reduction of the flue gas cleaning costs and will reduce, by this, the electricity production costs

  13. Economic impacts of power electronics on electricity distribution systems

    International Nuclear Information System (INIS)

    Duarte, Carlos Henrique; Schaeffer, Roberto

    2010-01-01

    To achieve more efficient energy use, power electronics (PEs) may be employed. However, these introduce nonlinear loads (NLLs) into the system by generating undesired frequencies that are harmonic in relation to (multiples of) the fundamental frequency (60 Hz in Brazil). Consequently, devices using PEs are more efficient but also contribute significantly to degradation of power quality. Besides this, both the conventional rules on design and operation of power systems and the usual premises followed in energy efficiency programs (without mentioning the electricity consumed by the devices themselves) consider the sinusoidal voltage and current waveforms at the fixed fundamental frequency of the power grid. Thus, analysis of electricity consumption reductions in energy efficiency programs that include the use of PEs considers the reduction of kWh to the final consumer but not the additional losses caused by the increase in harmonic distortion. This article contributes to a better understanding of this problem by reporting the results of a case study of the ownership and use of television sets (TV sets) to estimate the economic impacts of residential PEs on a mainly residential electricity distribution system. (author)

  14. Design and analysis of solar thermoelectric power generation system

    Science.gov (United States)

    Vatcharasathien, Narong; Hirunlabh, Jongjit; Khedari, Joseph; Daguenet, Michel

    2005-09-01

    This article reports on the design and performance analysis of a solar thermoelectric power generation plant (STEPG). The system considers both truncated compound parabolic collectors (CPCs) with a flat receiver and conventional flat-plate collectors, thermoelectric (TE) cooling and power generator modules and appropriate connecting pipes and control devices. The design tool uses TRNSYS IIsibat-15 program with a new component we developed for the TE modules. The main input data of the system are the specifications of TE module, the maximum hot side temperature of TE modules, and the desired power output. Examples of the design using truncated CPC and flat-plate collectors are reported and discussed for various slope angle and half-acceptance angle of CPC. To minimize system cost, seasonal adjustment of the slope angle between 0° and 30° was considered, which could give relatively high power output under Bangkok ambient condition. Two small-scale STEPGs were built. One of them uses electrical heater, whereas the other used a CPC with locally made aluminum foil reflector. Measured data showed reasonable agreement with the model outputs. TE cooling modules were found to be more appropriate. Therefore, the TRNSYS software and the developed TE component offer an extremely powerful tool for the design and performance analysis of STEPG plant.

  15. A Technical, Economic, and Environmental Performance of Grid-Connected Hybrid (Photovoltaic-Wind) Power System in Algeria

    OpenAIRE

    Saheb-Koussa, Djohra; Koussa, Mustapha; Said, Nourredine

    2013-01-01

    This paper studies the technical, economic, and environmental analysis of wind and photovoltaic power systems connected to a conventional grid. The main interest in such systems is on-site consumption of the produced energy, system hybridization, pooling of resources, and contribution to the environment protection. To ensure a better management of system energy, models have been used for determining the power that the constituting subsystems can deliver under specific weather conditions. Simu...

  16. A Study on the Application for Enhancing the Transmission Capability of the KEPCO Power System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Han; Kwon, Tea Won; Whang, Jong Young; Lee, Gun Joon; Kim, Tae Hoon; Chang, Byung Hoon; Min, Wan Ki [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Park, Young Moon; Park, Jong Gun [Seoul National University, Seoul (Korea, Republic of); Kim, Gun Joong [Chungnam National University, Taejon (Korea, Republic of); Oh, Tae Kwu; Choi, Kwu Hyung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    Investigation of stability for power system in 2000 year and 2006 year by using the analysis of real power system. Comparative investigation of the conventional transmission line upgrading methods such as HVDC, HOP, new conductor scheme. Investigation of FACTS, the recent transmission line upgrading method, with respect to the aspect of technique and cost and effect analysis when this method is applied to real power system. Development of the evaluation method of transmission type that should be considered when above method is applied to real power system with respect to aspect of technique and cost. Development of a long-range plan for the transmission capacity upgrading and the evaluation method of reliability. (author).

  17. Development and experiment of a 60 kW horizontal-axis marine current power system

    International Nuclear Information System (INIS)

    Xu, Quan-kun; Liu, Hong-wei; Lin, Yong-gang; Yin, Xiu-xing; Li, Wei; Gu, Ya-jing

    2015-01-01

    A 60 kW horizontal-axis marine current power system is designed, built and tested to provide potentially cost-competitive electrical power for residents in remote islands. This power system mainly consists of a three-bladed marine current turbine, a drive-train system, power electronics and a control console. The turbine blade parameters are reasonably calculated and optimized based on the blade element momentum theory. The hydrodynamic performances of this turbine are predicted over a wide range of operating conditions. An adequate drive-train system is carefully designed to make the marine power system work smoothly and quietly even under harsh marine current conditions. The control console is also developed to facilitate the condition monitoring and generator power and speed regulations for this power system by adequately controlling the onshore power electronics. This power system has been tested under real marine current conditions to thoroughly evaluate its dynamic characteristics and effectiveness. - Highlights: • A 60°kW horizontal-axis marine current power system is designed, built and tested. • Detailed design procedure and experimental data are provided. • Experimental results demonstrate high power convention efficiency of the system

  18. Abort kicker power supply systems at Fermilab

    International Nuclear Information System (INIS)

    Krafczyk, G.; Dugan, G.; Harrison, M.; Koepke, K.; Tilles, E.

    1985-01-01

    Over the past several years, Fermilab has been operating with a single turn proton abort system in both the superconducting Tevatron and the conventional Main Ring. The abort kicker power supply for this system discharges a lumped capacitance into the inductive magnet load, causing the beam to enter the abort channel. A unique feature of this design is the high voltage, high current diode assembly used to clip the recharge of the capacitor bank. This allows the current to decay slowly with the L/R time constant of the magnet and diode series combination. Special attention will be given to the diode characteristics needed for this passive switching element. Operational experience and proposed upgrades will be given for the two operational systems

  19. Modelling and automatic reactive power control of isolated wind-diesel hybrid power systems using ANN

    International Nuclear Information System (INIS)

    Bansal, R.C.

    2008-01-01

    This paper presents an artificial neural network (ANN) based approach to tune the parameters of the static var compensator (SVC) reactive power controller over a wide range of typical load model parameters. The gains of PI (proportional integral) based SVC are optimised for typical values of the load voltage characteristics (n q ) by conventional techniques. Using the generated data, the method of multi-layer feed forward ANN with error back propagation training is employed to tune the parameters of the SVC. An ANN tuned SVC controller has been applied to control the reactive power of a variable slip/speed isolated wind-diesel hybrid power system. It is observed that the maximum deviations of all parameters are more for larger values of n q . It has been shown that initially synchronous generator supplies the reactive power required by the induction generator and/or load, and the latter reactive power is purely supplied by the SVC

  20. Modelling and automatic reactive power control of isolated wind-diesel hybrid power systems using ANN

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, R.C. [Electrical and Electronics Engineering Division, School of Engineering and Physics, The University of the South Pacific, Suva (Fiji)

    2008-02-15

    This paper presents an artificial neural network (ANN) based approach to tune the parameters of the static var compensator (SVC) reactive power controller over a wide range of typical load model parameters. The gains of PI (proportional integral) based SVC are optimised for typical values of the load voltage characteristics (n{sub q}) by conventional techniques. Using the generated data, the method of multi-layer feed forward ANN with error back propagation training is employed to tune the parameters of the SVC. An ANN tuned SVC controller has been applied to control the reactive power of a variable slip/speed isolated wind-diesel hybrid power system. It is observed that the maximum deviations of all parameters are more for larger values of n{sub q}. It has been shown that initially synchronous generator supplies the reactive power required by the induction generator and/or load, and the latter reactive power is purely supplied by the SVC. (author)

  1. Electrical Market Management Considering Power System Constraints in Smart Distribution Grids

    Directory of Open Access Journals (Sweden)

    Poria Hasanpor Divshali

    2016-05-01

    Full Text Available Rising demand, climate change, growing fuel costs, outdated power system infrastructures, and new power generation technologies have made renewable distribution generators very attractive in recent years. Because of the increasing penetration level of renewable energy sources in addition to the growth of new electrical demand sectors, such as electrical vehicles, the power system may face serious problems and challenges in the near future. A revolutionary new power grid system, called smart grid, has been developed as a solution to these problems. The smart grid, equipped with modern communication and computation infrastructures, can coordinate different parts of the power system to enhance energy efficiency, reliability, and quality, while decreasing the energy cost. Since conventional distribution networks lack smart infrastructures, much research has been recently done in the distribution part of the smart grid, called smart distribution grid (SDG. This paper surveys contemporary literature in SDG from the perspective of the electricity market in addition to power system considerations. For this purpose, this paper reviews current demand side management methods, supply side management methods, and electrical vehicle charging and discharging techniques in SDG and also discusses their drawbacks. We also present future research directions to tackle new and existing challenges in the SDG.

  2. Digital Components in Swedish NPP Power Systems

    International Nuclear Information System (INIS)

    Karlsson, Mattias; Eriksson, Tage

    2015-01-01

    Swedish nuclear power plants have over the last 20 years of operation modernised or exchanged several systems and components of the electrical power system. Within these works, new components based on digital technology have been employed in order to realize functionality that was previously achieved by using electro-mechanical or analogue technology. Components and systems such as relay protection, rectifiers, inverters, variable speed drives and diesel-generator sets are today equipped with digital components. Several of the systems and components fulfil functions with a safety-role in the NPP. Recently, however, a number of incidents have occurred which highlight deficiencies in the design or HMI of the equipment, which warrants questions whether there are generic problems with some applications of digital components that needs to be addressed. The use of digital components has presented cost effective solutions, or even the only available solution on the market enabling a modernisation. The vast majority of systems using digital components have been operating without problems and often contribute to improved safety but the challenge of non-detectable, or non-identifiable, failure modes remain. In this paper, the extent to which digital components are used in Swedish NPP power systems will be presented including a description of typical applications. Based on data from maintenance records and fault reports, as well as interviews with designers and maintenance personnel, the main areas where problems have been encountered and where possible risks have been identified will be described. The paper intends to investigate any 'tell-tales' that could give signals of unwanted behaviour. Furthermore, particular benefits experienced by using digital components will be highlighted. The paper will also discuss the safety relevance of these findings and suggest measures to improve safety in the application of digital components in power systems. (authors)

  3. Implicit Particle Filter for Power System State Estimation with Large Scale Renewable Power Integration.

    Science.gov (United States)

    Uzunoglu, B.; Hussaini, Y.

    2017-12-01

    Implicit Particle Filter is a sequential Monte Carlo method for data assimilation that guides the particles to the high-probability by an implicit step . It optimizes a nonlinear cost function which can be inherited from legacy assimilation routines . Dynamic state estimation for almost real-time applications in power systems are becomingly increasingly more important with integration of variable wind and solar power generation. New advanced state estimation tools that will replace the old generation state estimation in addition to having a general framework of complexities should be able to address the legacy software and able to integrate the old software in a mathematical framework while allowing the power industry need for a cautious and evolutionary change in comparison to a complete revolutionary approach while addressing nonlinearity and non-normal behaviour. This work implements implicit particle filter as a state estimation tool for the estimation of the states of a power system and presents the first implicit particle filter application study on a power system state estimation. The implicit particle filter is introduced into power systems and the simulations are presented for a three-node benchmark power system . The performance of the filter on the presented problem is analyzed and the results are presented.

  4. A Grid Voltage Measurement Method for Wind Power Systems during Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Cheol-Hee Yoo

    2014-11-01

    Full Text Available Grid codes in many countries require low-voltage ride-through (LVRT capability to maintain power system stability and reliability during grid fault conditions. To meet the LVRT requirement, wind power systems must stay connected to the grid and also supply reactive currents to the grid to support the recovery from fault voltages. This paper presents a new fault detection method and inverter control scheme to improve the LVRT capability for full-scale permanent magnet synchronous generator (PMSG wind power systems. Fast fault detection can help the wind power systems maintain the DC-link voltage in a safe region. The proposed fault detection method is based on on-line adaptive parameter estimation. The performance of the proposed method is verified in comparison to the conventional voltage measurement method defined in the IEC 61400-21 standard.

  5. Energy balance in olive oil farms: comparison of organic and conventional farming systems.

    Science.gov (United States)

    Moreno, Marta M.; Meco, Ramón; Moreno, Carmen

    2013-04-01

    The viability of an agricultural production system not only depends on the crop yields, but especially on the efficient use of available resources. However, the current agricultural systems depend heavily on non-renewable energy consumption in the form of fertilizers, fossil fuels, pesticides and machinery. In developed countries, the economic profitability of different productive systems is dependent on the granting of subsidies of diverse origin that affect both production factors (or inputs) and the final product (or output). Leaving such external aids, energy balance analysis reveals the real and most efficient form of management for each agroclimatic region, and is also directly related to the economic activity and the environmental state. In this work we compare the energy balance resulting from organic and conventional olive oil farms under the semi-arid conditions of Central Spain. The results indicate that the mean energy supplied to the organic farms was sensitively lower (about 30%) in comparison with the conventional management, and these differences were more pronounced for the biggest farms (> 15 ha). Mean energy outputs were about 20% lower in the organic system, although organic small farms (ratio scarcely reached 25%. Human labor item only represented a very small amount of the total energy input in both cases (less than 1%). As conclusions, both management systems were efficient from an energy point of view. The value of the organic production should be focused on the environmental benefits it provides, which are not usually considered in the conventional management on not valuing the damage it produces to the environment. Organic farming would improve the energy efficiency in these environmental conditions, offering a sustainable production with minimal inputs.

  6. Simulation of solar-powered ammonia-water integrated hybrid cooling system

    International Nuclear Information System (INIS)

    Chinnappa, J.C.V.; Wijeysundera, N.E.

    1992-01-01

    A number of solar-operated air-conditioning systems based on the H 2 O-LiBr absorption chiller were built, installed, and monitored. A systematic study at the University of Colorado has been published. This paper presents a simple cost-benefit analysis of the conventional vapor compression system (VCS), the vapor absorption system (VAS), and the integrated hybrid system (IHS). The cost of energy input to the VAS and the IHS were compared with the energy cost of the VCS that these solar-powered systems replace. It was found that cost savings can be realized with solar-powered systems, only after a critical overall solar fraction is exceeded. Typically, this value was about 0.7 for a VAS and about 0.12 for a IHS. These cost-benefit results provided the motivation for a more detailed study of the IHS. There has also been other efforts in this direction

  7. A Cost to Benefit Analysis of a Next Generation Electric Power Distribution System

    Science.gov (United States)

    Raman, Apurva

    This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast protection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs. Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this reflects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a

  8. Power system relaying

    CERN Document Server

    Horowitz, Stanley H; Niemira, James K

    2013-01-01

    The previous three editions of Power System Relaying offer comprehensive and accessible coverage of the theory and fundamentals of relaying and have been widely adopted on university and industry courses worldwide. With the third edition, the authors have added new and detailed descriptions of power system phenomena such as stability, system-wide protection concepts and discussion of historic outages. Power System Relaying, 4th Edition continues its role as an outstanding textbook on power system protection for senior and graduate students in the field of electric power engineering and a refer

  9. Nutritional Evaluation of Non-Conventional Vegetables in Brazil.

    Science.gov (United States)

    Silva, Luis Felipe Lima E; Souza, Douglas C DE; Resende, Luciane V; Nassur, Rita DE Cássia M R; Samartini, Carolina Q; Gonçalves, Wilson M

    2018-01-01

    The objective of this study was to characterize the nutritional compounds of interest present in vegetables known as non-conventional, in Brazil. The following evaluations were carried out: antioxidant activity, phenolic compounds, vitamin C, calories, carbohydrates, humidity, lipids, proteins, fiber, acidity and quantification of minerals (P, K, Ca, Mg, S, Cu, Fe, Mn, Zn and B). The species studied were Amaranthus hybridus L., Amaranthus viridis L., Basella alba L., Eryngium campestre L., Hibiscus sabdariffa L., Lactuca canadensis L., Rumex acetosa L., Stachys byzantina K. Koch, Tropaeolum majus L. and Xanthosoma sagittifolium L. Representative samples of plant structures of interest were harvested from each species suitable for human consumption such as leaves, flowers and flower buds. The results were submitted to multivariate analysis - principal components analysis (PCA). All the species present nutritional compounds of interest in different levels among the evaluated structures.

  10. Wind power in modern power systems

    DEFF Research Database (Denmark)

    Chen, Zhe

    2013-01-01

    In recent years, wind power is experiencing a rapid growth, and large-scale wind turbines/wind farms have been developed and connected to power systems. However, the traditional power system generation units are centralized located synchronous generators with different characteristics compared...... with wind turbines. This paper presents an overview of the issues about integrating large-scale wind power plants into modern power systems. Firstly, grid codes are introduced. Then, the main technical problems and challenges are presented. Finally, some possible technical solutions are discussed....

  11. Computerized information system of the Mochovce nuclear power plant

    International Nuclear Information System (INIS)

    Holik, V.

    1986-01-01

    The computer-based information system for the Mochovce nuclear power plant has a hierarchic structure which incorporates SM 1804 microcomputers and SM 1420 minicomputers. With regard to operation it is divided into two levels: the information system at the level of power plant units and the information system t the level of the whole power plant. The information system of a unit provides the collection of information on the technological equipment of each unit for the operative control of the unit and documentation on unit operation. Each unit has its own independent computer information system. The actual nucleus of each unit information system consists of two computer complexes based on SM 1420 twin computers, mutually substitutional. The power plant level information system provides the processing and output of information for personnel in the central control room of the power plant and for other managerial staff. It uses preprocessed information from the unit information systems and direct information from non-unit installations and from dosimetric control rooms of the power plant units. This information system is also based on a computer complex with two SM 1420 computers. (Z.M.)

  12. Development of quench detection/protection system based on active power method for superconducting magnet by using capacitor circuit

    International Nuclear Information System (INIS)

    Nanato, N.; Otsuka, T.; Hesaka, S.; Murase, S.

    2013-01-01

    Highlights: ► The authors have presented an active power method for quench detection. ► A method for improving its characteristics using a capacitor circuit was proposed. ► Quench detection/protection test for a Bi2223 superconducting coil was carried out. ► The proposed method was more useful than the conventional one. -- Abstract: When a quench occurs in a superconducting magnet, excessive joule heating in normal region may damage the magnet. It is necessary to detect the quench as soon as possible and discharge magnetic energy stored in the magnet. The authors have presented a quench detection/protection system based on an active power method which detects the quench regardless of a self-inductive and mutual-inductive voltages and electromagnetic noise. In the conventional active power method, the inductive voltages are removed by cancel coils. In this paper, the authors propose a method to cancel an inductive voltage using a capacitor circuit. The quench detection/protection system becomes more precise and smaller than the conventional system through the capacitor circuit

  13. Ultra-low power transmitter for encoding non-MR signals in Magnetic Resonance (MR) recordings

    DEFF Research Database (Denmark)

    Petersen, Jan Raagaard; Pedersen, Jan Ole; Zhurbenko, Vitaliy

    collection of data from non-MRI sensors. The transmitter consumes only 1.3mW while transmitting 2.7µW at 120MHz with high frequency stability. The presented design is useful in low power applications requiring high frequency stability and is intended for wireless transmission of non-MR signal recordings......Advancing Magnetic Resonance Imaging (MRI) technology requires integration of the MRI scanners with sensors and systems for monitoring various non-MRI signals. In this paper, we present design and integration of a low power AM radio transmitter into a 3T MRI scanner, which can be used for efficient...

  14. Considering system non-linearity in transmission pricing

    International Nuclear Information System (INIS)

    Oloomi-Buygi, M.; Salehizadeh, M. Reza

    2008-01-01

    In this paper a new approach for transmission pricing is presented. The contribution of a contract on power flow of a transmission line is used as extent-of-use criterion for transmission pricing. In order to determine the contribution of each contract on power flow of each transmission line, first the contribution of each contract on each voltage angle is determined, which is called voltage angle decomposition. To this end, DC power flow is used to compute a primary solution for voltage angle decomposition. To consider the impacts of system non-linearity on voltage angle decomposition, a method is presented to determine the share of different terms of sine argument in sine value. Then the primary solution is corrected in different iterations of decoupled Newton-Raphson power flow using the presented sharing method. The presented approach is applied to a 4-bus test system and IEEE 30-bus test system and the results are analyzed. (author)

  15. Simulation of onboard power supply system for small hydrographic vessel «Vaygach»

    Directory of Open Access Journals (Sweden)

    А. И. Паньков

    2016-12-01

    Full Text Available Computer simulation is a method resorted to more and more frequently for the development of the prospective power supply systems, in particular the vessel power supply system. It provides valuable insights into the transient processes and indicators of electric power quality in the system without building its physical model, thus significantly improving the efficiency and quality of the physical model.Nowadays MathLab package with Simulink application is used with increasing frequency for simulation of such systems.The paper presents a model of the power supply system of small hydrographic vessel ‘Vaygach’ built in MatLab environment. The system vulnerabilities and their remedies have been identified. Changes in sinusoid before and after the non-linear load on the network have been demonstrated and solutions for improving the non-linear distortion factor are proposed. The model developed for the vessel power supply system can be used for building models of different vessels.

  16. Non-HIV Pneumocystis pneumonia: do conventional community-acquired pneumonia guidelines under estimate its severity?

    Directory of Open Access Journals (Sweden)

    Asai Nobuhiro

    2012-06-01

    Full Text Available Abstract Background Non-HIV Pneumocystis pneumonia (PCP can occur in immunosuppressed patients having malignancy or on immunosuppressive agents. To classify severity, the A-DROP scale proposed by the Japanese Respiratory Society (JRS, the CURB-65 score of the British Respiratory Society (BTS and the Pneumonia Severity Index (PSI of the Infectious Diseases Society of America (IDSA are widely used in patients with community-acquired pneumonia (CAP in Japan. To evaluate how correctly these conventional prognostic guidelines for CAP reflect the severity of non-HIV PCP, we retrospectively analyzed 21 patients with non-HIV PCP. Methods A total of 21 patients were diagnosed by conventional staining and polymerase chain reaction (PCR for respiratory samples with chest x-ray and computed tomography (CT findings. We compared the severity of 21 patients with PCP classified by A-DROP, CURB-65, and PSI. Also, patients’ characteristics, clinical pictures, laboratory results at first visit or admission and intervals from diagnosis to start of specific-PCP therapy were evaluated in both survivor and non-survivor groups. Results Based on A-DROP, 18 patients were classified as mild or moderate; respiratory failure developed in 15 of these 18 (83.3%, and 7/15 (46.7% died. Based on CURB-65, 19 patients were classified as mild or moderate; respiratory failure developed in 16/19 (84.2%, and 8 of the 16 (50% died. In contrast, PSI classified 14 as severe or extremely severe; all of the 14 (100% developed respiratory failure and 8/14 (57.1% died. There were no significant differences in laboratory results in these groups. The time between the initial visit and diagnosis, and the time between the initial visit and starting of specific-PCP therapy were statistically shorter in the survivor group than in the non-survivor group. Conclusions Conventional prognostic guidelines for CAP could underestimate the severity of non-HIV PCP, resulting in a therapeutic delay

  17. Siemens's spectrum of deliveries and services for nuclear power plants

    International Nuclear Information System (INIS)

    2011-01-01

    In 2001, Siemens and Framatome merged their nuclear activities in the present Areva NP joint venture. Siemens has since focused on the construction and further development of conventional power plants and on the so-called conventional island (CI), the non-nuclear part of a nuclear power plant, i.e. the steam turbine, generator, and plant I and C systems, and also on service for the conventional part of nuclear power plants. Its role as a minority shareholder in Areva NP constrained Siemens. For this reason, the company in January 2009 decided to terminate its interest in Areva NP effective January 30, 2012. By January 2012 at the latest, Siemens will transfer to the majority shareholder Areva, holding 66 percent of the shares, its interest in the joint venture. For the time being, the joint venture still entails certain limitations to Siemens's activities in the nuclear field. Its delivery of the conventional island for the Olkiluoto 3 (OL3) nuclear power plant in Finland confirms the company's know-how in power plant construction. When commissioned, its 1,720 MW power will make OL3 the world's largest nuclear generating unit. The turbo-generator of the CI comprises a double-flow HP turbine and a 6-flow LP turbine. The driven 4-pole generator with a power of up to 2,200 MVA consists of a water-cooled stator and a hydrogen-cooled rotor. (orig.)

  18. Effect of PID Power System Stabilizer for a Synchronous Machine in Simulink Environment

    International Nuclear Information System (INIS)

    Yi, Tan Qian; Kasilingam, Gowrishankar; Raguraman, Raman

    2013-01-01

    This paper presents the use of Proportional-Integral-Derivative (PID) Controller with power system stabilizer (PSS) in a single machine infinite bus system. A PSS is used to generate supplementary damping control signals for an excitation system in order to damp out low frequency oscillations (LFO) of an electric power system. The paper is modelled in the MATLAB Simulink Environment to analyze the performance of a synchronous machine under a wide range of operating conditions. The functional blocks of PID controller with PSS are generated and the simulation studies are conducted based on different test cases to observe the dynamic performance of the power system. Analysis in this paper reveals that the PID-PSS gives better dynamic performance as compared to that of conventional power system stabilizer and also the optimal gain settings of PID PSS obtained at normal operating condition works well to other operating condition without much deterioration of the dynamic responses.

  19. Small power and heat generation systems on the basis of propulsion and innovative reactor technologies. Proceedings of an advisory group meeting

    International Nuclear Information System (INIS)

    2000-09-01

    In the future for developing regions and remote areas one or two power reactors in the 50 MWe to 100 MWe range could be appropriately applied for electricity and heat generation. Introducing and managing such a small program with conventional reactor systems would require a mature supporting technological infrastructure and many skilled highly-trained staff at the site, which might be a problem in some countries. An increased number of small conventional reactors would increase the burden and expenditure for assuring security and non-proliferation. To this end, the time has come to develop an innovative small reactor concept which meets the following requirements: reliable, safe operation with a minimum maintenance and supporting infrastructure, economic competitiveness with alternative energy sources available to the candidate sites, and significant improvements in proliferation resistance relative to existing reactor systems. Successful resolution of such a problem requires a comprehensive system approach that considers all aspects of manufacturing, transportation, operation and ultimate disposal. Some elements of this approach have been used previously in the development of propulsion nuclear power systems, with consideration given to many diverse requirements such as highly autonomous operation for a long period of time, no planned maintenance, no on-site refueling and ultimate disposition. It is with this focus that the IAEA convened the Advisory Group on Propulsion Reactor technologies for Civilian Applications

  20. Small power and heat generation systems on the basis of propulsion and innovative reactor technologies. Proceedings of an advisory group meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    In the future for developing regions and remote areas one or two power reactors in the 50 MWe to 100 MWe range could be appropriately applied for electricity and heat generation. Introducing and managing such a small program with conventional reactor systems would require a mature supporting technological infrastructure and many skilled highly-trained staff at the site, which might be a problem in some countries. An increased number of small conventional reactors would increase the burden and expenditure for assuring security and non-proliferation. To this end, the time has come to develop an innovative small reactor concept which meets the following requirements: reliable, safe operation with a minimum maintenance and supporting infrastructure, economic competitiveness with alternative energy sources available to the candidate sites, and significant improvements in proliferation resistance relative to existing reactor systems. Successful resolution of such a problem requires a comprehensive system approach that considers all aspects of manufacturing, transportation, operation and ultimate disposal. Some elements of this approach have been used previously in the development of propulsion nuclear power systems, with consideration given to many diverse requirements such as highly autonomous operation for a long period of time, no planned maintenance, no on-site refueling and ultimate disposition. It is with this focus that the IAEA convened the Advisory Group on Propulsion Reactor technologies for Civilian Applications.

  1. Genome and metabolic engineering in non-conventional yeasts: Current advances and applications.

    Science.gov (United States)

    Löbs, Ann-Kathrin; Schwartz, Cory; Wheeldon, Ian

    2017-09-01

    Microbial production of chemicals and proteins from biomass-derived and waste sugar streams is a rapidly growing area of research and development. While the model yeast Saccharomyces cerevisia e is an excellent host for the conversion of glucose to ethanol, production of other chemicals from alternative substrates often requires extensive strain engineering. To avoid complex and intensive engineering of S. cerevisiae, other yeasts are often selected as hosts for bioprocessing based on their natural capacity to produce a desired product: for example, the efficient production and secretion of proteins, lipids, and primary metabolites that have value as commodity chemicals. Even when using yeasts with beneficial native phenotypes, metabolic engineering to increase yield, titer, and production rate is essential. The non-conventional yeasts Kluyveromyces lactis, K. marxianus, Scheffersomyces stipitis, Yarrowia lipolytica, Hansenula polymorpha and Pichia pastoris have been developed as eukaryotic hosts because of their desirable phenotypes, including thermotolerance, assimilation of diverse carbon sources, and high protein secretion. However, advanced metabolic engineering in these yeasts has been limited. This review outlines the challenges of using non-conventional yeasts for strain and pathway engineering, and discusses the developed solutions to these problems and the resulting applications in industrial biotechnology.

  2. Workshop on materials science and the physics of non-conventional energy sources

    International Nuclear Information System (INIS)

    Furlan, G.; Nobili, D.; Sayigh, A.M.; Seraphin, B.O.

    1989-01-01

    The non-conventional energy activities started in 1974, on the island of Procida, Italy. About 50 leading physicists and engineers got together for two weeks in September to discuss the states of the art and consult with each other about various devices and ways of energy conversion. The esteemed Nobel Prize Laureate, Professor Abdus Salam, accepted to have the first meeting on non-conventional energy at the ICTP, Trieste, in September 1977. In 1987, the meeting was once again back in Trieste, Italy. Also, during the even years since 1978 until 1986, meetings were held in Trieste in the French language. The results of the last 10 years at ICTP are very clear to all fellow scientist and engineers. Some 150 applicants are chosen every year. The workshop is being graded gradually to emphasize the high technology and up-to-date achievements in the field. A good proportion of the physicists who were with us from the beginning are now top experts in the field and in charge of existing programmes in their own countries. The present programme emphasized the following topics: Material Science; Solar Energy Conversion with concentration on Photovoltaic Conversion; and Energy Storage. Refs, figs and tabs

  3. A non-conventional isotope separation cascade without any mixing: net cascade

    International Nuclear Information System (INIS)

    Zeng Shi; Jiang Dongjun; Ying Zhengen

    2012-01-01

    A component has different concentrations in the incoming flows at a confluent point in all existing isotope separations cascades for multi-component isotope separation and mixing is inevitable, which results in deterioration of separation performance of the separation cascade. However, realization of no-mixing at a confluent point is impossible with a conventional cascade. A non-conventional isotope separation cascade, net cascade, is found to be able to realize no mixings for all components at confluent points, and its concept is further developed here. No-mixing is fulfilled by requiring symmetrical separation of two specified key components at every stage, and the procedure of realizing no-mixing is presented in detail. Some properties of net cascade are investigated preliminarily, and the results demonstrated the no-mixing property is indeed realized. Net cascade is the only separation cascade that so far possesses the no-mixing property. (authors)

  4. Orthodontic forces released by low-friction versus conventional systems during alignment of apically or buccally malposed teeth.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Camporesi, Matteo; Defraia, Efisio

    2011-02-01

    The aim of the present study was to analyse the forces released by passive stainless steel self-ligating brackets (SLBs) and by a non-conventional elastomeric ligature-bracket system on conventional brackets ([slide ligatures on conventional brackets (SLCB)]) when compared with conventional elastomeric ligatures on conventional brackets (CLCB) during the alignment of apically or buccally malposed teeth in the maxillary arch. An experimental model consisting of five brackets was used to assess the forces released by the three different bracket-ligature systems with 0.012-inch super-elastic (SE) nickel-titanium (NiTi) wires in the presence of different amounts of apical or buccal canine misalignment of the canine (ranging from 1.5 to 6 mm). The forces released by each wire/bracket/ligature combination with the three different amounts of apical or buccal canine misalignment were tested 20 times. Comparisons between the different types of wire/bracket/ligature systems were carried out by means of analysis of variance on ranks with Dunnett's post hoc test (P < 0.05). No difference in the amount of force released in presence of a misalignment of 1.5 mm was recorded among the three systems. At 3 mm of apical misalignment a significantly greater amount of orthodontic force was released by SLB or SLCB when compared with CLCB, while no significant differences were found among the three systems at 3 mm of buccal canine displacement. When correction of a large amount of misalignment (6 mm) was attempted, a noticeable amount of force for alignment was still generated by the passive SLB and SLCB systems while no force was released in presence of CLCB.

  5. An Appropriate Wind Model for Wind Integrated Power Systems Reliability Evaluation Considering Wind Speed Correlations

    Directory of Open Access Journals (Sweden)

    Rajesh Karki

    2013-02-01

    Full Text Available Adverse environmental impacts of carbon emissions are causing increasing concerns to the general public throughout the world. Electric energy generation from conventional energy sources is considered to be a major contributor to these harmful emissions. High emphasis is therefore being given to green alternatives of energy, such as wind and solar. Wind energy is being perceived as a promising alternative. This source of energy technology and its applications have undergone significant research and development over the past decade. As a result, many modern power systems include a significant portion of power generation from wind energy sources. The impact of wind generation on the overall system performance increases substantially as wind penetration in power systems continues to increase to relatively high levels. It becomes increasingly important to accurately model the wind behavior, the interaction with other wind sources and conventional sources, and incorporate the characteristics of the energy demand in order to carry out a realistic evaluation of system reliability. Power systems with high wind penetrations are often connected to multiple wind farms at different geographic locations. Wind speed correlations between the different wind farms largely affect the total wind power generation characteristics of such systems, and therefore should be an important parameter in the wind modeling process. This paper evaluates the effect of the correlation between multiple wind farms on the adequacy indices of wind-integrated systems. The paper also proposes a simple and appropriate probabilistic analytical model that incorporates wind correlations, and can be used for adequacy evaluation of multiple wind-integrated systems.

  6. Local, organic food initiatives and their potentials for transforming the conventional food system

    Directory of Open Access Journals (Sweden)

    Geir Lieblein

    2005-05-01

    Full Text Available L’objectif de cet article est de discuter l’importance des initiatives locales dans la distribution de produits biologiques. Le sujet est abordé d’une part en fonction de la relation entre ce type d’initiatives et le système agroalimentaire conventionnel et d’autre part en fonction de la possibilité du développement d’un système agroalimentaire plus durable. Basé sur trois études scandinaves, concernant des produits biologiques en Norvège et au Danemark, cet article souligne le fait que les différents acteurs intreviewés jouent à la fois sur le tableau du local et du biologique et sur le tableau du conventionnel. En dépit de différences structurelles distinctes, les deux systèmes, et les conventions qui leur sont rattachées, s’influencent mutuellement. Afin de mettre au point une agriculture plus durable, il semble donc important de mettre en valeur le fondement global de l’agriculture écologique, qui repose non seulement sur des valeurs biologiques et locales, mais encore sur des aspects économiques, sociaux et culturels qui doivent être pris en considération.The aim of this article is to discuss the importance of local initiatives for distribution of organic food. This subject is discussed both in relation to how such initiatives may affect the overall conventional food system and the possible implications for development of a more sustainable food system. The article is based on findings from three different cases of local, organic food in Norway and Denmark. We found that actors within the cases are both involved with local, organic food initiatives and at the same time part of the overall conventional food system. Even though there are distinctive structural differences between these distribution systems, they mutually affect each other. This means that conventions normally associated with local, organic food systems may ‘rub off’ to the conventional food system and vice versa. In order to develop

  7. New design solutions for low-power energy production in water pipe systems

    Directory of Open Access Journals (Sweden)

    Helena M. Ramos

    2009-12-01

    Full Text Available This study is the result of ongoing research for a European Union 7th Framework Program Project regarding energy converters for very low heads, and aims to analyze optimization of new cost-effective hydraulic turbine designs for possible implementation in water supply systems (WSSs or in other pressurized water pipe infrastructures, such as irrigation, wastewater, or drainage systems. A new methodology is presented based on a theoretical, technical and economic analysis. Viability studies focused on small power values for different pipe systems were investigated. Detailed analyses of alternative typical volumetric energy converters were conducted on the basis of mathematical and physical fundamentals as well as computational fluid dynamics (CFD associated with the interaction between the flow conditions and the system operation. Important constraints (e.g., size, stability, efficiency, and continuous steady flow conditions can be identified and a search for alternative rotary volumetric converters is being conducted. As promising cost-effective solutions for the coming years, adapted rotor-dynamic turbomachines and non-conventional axial propeller devices were analyzed based on the basic principles of pumps operating as turbines, as well as through an extensive comparison between simulations and experimental tests.

  8. The Kibble-Zurek mechanism in phase transitions of non-equilibrium systems

    Science.gov (United States)

    Cheung, Hil F. H.; Patil, Yogesh S.; Date, Aditya G.; Vengalattore, Mukund

    2017-04-01

    We experimentally realize a driven-dissipative phase transition using a mechanical parametric amplifier to demonstrate key signatures of a second order phase transition, including a point where the susceptibilities and relaxation time scales diverge, and where the system exhibits a spontaneous breaking of symmetry. Though reminiscent of conventional equilibrium phase transitions, it is unclear if such driven-dissipative phase transitions are amenable to the conventional Landau-Ginsburg-Wilson paradigm, which relies on concepts of scale invariance and universality, and recent work has shown that such phase transitions can indeed lie beyond such conventional universality classes. By quenching the system past the critical point, we investigate the dynamics of the emergent ordered phase and find that our measurements are in excellent agreement with the Kibble-Zurek mechanism. In addition to verifying the Kibble-Zurek hypothesis in driven-dissipative phase transitions for the first time, we also demonstrate that the measured critical exponents accurately reflect the interplay between intrinsic coherent dynamics and environmental correlations, showing a clear departure from mean field exponents in the case of non-Markovian system-bath interactions. We further discuss how reservoir engineering and the imposition of artificial environmental correlations can result in the stabilization of novel many-body quantum phases and aid in the creation of exotic non-equilibrium states of matter.

  9. Optimal Power Flow by Interior Point and Non Interior Point Modern Optimization Algorithms

    Directory of Open Access Journals (Sweden)

    Marcin Połomski

    2013-03-01

    Full Text Available The idea of optimal power flow (OPF is to determine the optimal settings for control variables while respecting various constraints, and in general it is related to power system operational and planning optimization problems. A vast number of optimization methods have been applied to solve the OPF problem, but their performance is highly dependent on the size of a power system being optimized. The development of the OPF recently has tracked significant progress both in numerical optimization techniques and computer techniques application. In recent years, application of interior point methods to solve OPF problem has been paid great attention. This is due to the fact that IP methods are among the fastest algorithms, well suited to solve large-scale nonlinear optimization problems. This paper presents the primal-dual interior point method based optimal power flow algorithm and new variant of the non interior point method algorithm with application to optimal power flow problem. Described algorithms were implemented in custom software. The experiments show the usefulness of computational software and implemented algorithms for solving the optimal power flow problem, including the system model sizes comparable to the size of the National Power System.

  10. REACTIVE POWER DEVICES IN SYSTEMS OF ELECTRIC TRACTION

    Directory of Open Access Journals (Sweden)

    M. O. Kostin

    2010-04-01

    Full Text Available A comparative characteristic of different concepts and expressions for determination of reactive power in the circuits with non-sinusoidal electric values has been given. For the first Ukrainian electric locomotives of DE1 type with the system of DC electric traction, the values of reactive power after Budeany, Fryze, and also the differential, integral and generalized reactive powers have been determined. Some measures on reducing its consumption by the DC electric rolling stock have been suggested.

  11. A Game Theoretical Approach Based Bidding Strategy Optimization for Power Producers in Power Markets with Renewable Electricity

    Directory of Open Access Journals (Sweden)

    Yi Tang

    2017-05-01

    Full Text Available In a competitive electricity market with substantial involvement of renewable electricity, maximizing profits by optimizing bidding strategies is crucial to different power producers including conventional power plants and renewable ones. This paper proposes a game-theoretic bidding optimization method based on bi-level programming, where power producers are at the upper level and utility companies are at the lower level. The competition among the multiple power producers is formulated as a non-cooperative game in which bidding curves are their strategies, while uniform clearing pricing is considered for utility companies represented by an independent system operator. Consequently, based on the formulated game model, the bidding strategies for power producers are optimized for the day-ahead market and the intraday market with considering the properties of renewable energy; and the clearing pricing for the utility companies, with respect to the power quantity from different power producers, is optimized simultaneously. Furthermore, a distributed algorithm is provided to search the solution of the generalized Nash equilibrium. Finally, simulation results were performed and discussed to verify the feasibility and effectiveness of the proposed non-cooperative game-based bi-level optimization approach.

  12. Convexity of Energy-Like Functions: Theoretical Results and Applications to Power System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Dvijotham, Krishnamurthy [California Inst. of Technology (CalTech), Pasadena, CA (United States); Low, Steven [California Inst. of Technology (CalTech), Pasadena, CA (United States); Chertkov, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-01-12

    Power systems are undergoing unprecedented transformations with increased adoption of renewables and distributed generation, as well as the adoption of demand response programs. All of these changes, while making the grid more responsive and potentially more efficient, pose significant challenges for power systems operators. Conventional operational paradigms are no longer sufficient as the power system may no longer have big dispatchable generators with sufficient positive and negative reserves. This increases the need for tools and algorithms that can efficiently predict safe regions of operation of the power system. In this paper, we study energy functions as a tool to design algorithms for various operational problems in power systems. These have a long history in power systems and have been primarily applied to transient stability problems. In this paper, we take a new look at power systems, focusing on an aspect that has previously received little attention: Convexity. We characterize the domain of voltage magnitudes and phases within which the energy function is convex in these variables. We show that this corresponds naturally with standard operational constraints imposed in power systems. We show that power of equations can be solved using this approach, as long as the solution lies within the convexity domain. We outline various desirable properties of solutions in the convexity domain and present simple numerical illustrations supporting our results.

  13. OPF-Based Optimal Location of Two Systems Two Terminal HVDC to Power System Optimal Operation

    Directory of Open Access Journals (Sweden)

    Mehdi Abolfazli

    2013-04-01

    Full Text Available In this paper a suitable mathematical model of the two terminal HVDC system is provided for optimal power flow (OPF and optimal location based on OPF such power injection model. The ability of voltage source converter (VSC-based HVDC to independently control active and reactive power is well represented by the model. The model is used to develop an OPF-based optimal location algorithm of two systems two terminal HVDC to minimize the total fuel cost and active power losses as objective function. The optimization framework is modeled as non-linear programming (NLP and solved by Matlab and GAMS softwares. The proposed algorithm is implemented on the IEEE 14- and 30-bus test systems. The simulation results show ability of two systems two terminal HVDC in improving the power system operation. Furthermore, two systems two terminal HVDC is compared by PST and OUPFC in the power system operation from economical and technical aspects.

  14. Resilient guaranteed cost control of a power system.

    Science.gov (United States)

    Soliman, Hisham M; Soliman, Mostafa H; Hassan, Mohammad F

    2014-05-01

    With the development of power system interconnection, the low-frequency oscillation is becoming more and more prominent which may cause system separation and loss of energy to consumers. This paper presents an innovative robust control for power systems in which the operating conditions are changing continuously due to load changes. However, practical implementation of robust control can be fragile due to controller inaccuracies (tolerance of resistors used with operational amplifiers). A new design of resilient (non-fragile) robust control is given that takes into consideration both model and controller uncertainties by an iterative solution of a set of linear matrix inequalities (LMI). Both uncertainties are cast into a norm-bounded structure. A sufficient condition is derived to achieve the desired settling time for damping power system oscillations in face of plant and controller uncertainties. Furthermore, an improved controller design, resilient guaranteed cost controller, is derived to achieve oscillations damping in a guaranteed cost manner. The effectiveness of the algorithm is shown for a single machine infinite bus system, and then, it is extended to multi-area power system.

  15. DESIGN AND TESTING OF A DIGITAL REGULATOR FOR FERMILAB MAGNET POWER SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Li Vigni, Vincenzo [Palermo U.

    2012-01-01

    In this thesis, the design of a digitally controlled DC power system for testing conventional and superconducting magnets is proposed. The designed PID controller performances have been tested by the 30kA test stand for superconducting magnets, Vertical Magnet Test Facility (VMTF), which is hosted at the Fermilab Magnet Test Facility (MTF). The system is implemented on a National Instruments CompactRIO and both real-time and FPGA targets are programmed. A full 24-bit PID algorithm is coded and successfully tested by a manual tuning approach. An automated tuning algorithm is then introduced. As it will be shown by simulation and experimental results, the proposed system meets all design specifications. The current loop stability is up to 14 times better than the existing regulator and a control accuracy less than 4 ppm is achieved. Shorted-bus tests of the PID regulator have been successfully performed on the VMTF power system. In order to test the generalization capability of the designed system towards different types of magnets, the system has been easily adapted to and tested on the 10kA conventional magnet test stand (Stand C at Fermilab). As shown by experimental results, the designed PID controller features really high performancesin terms of steady-state accuracy and effectiveness of the tuning algorithm.

  16. Transient characteristics of parallel running of the 20kVA superconducting synchronous generator and a conventional one

    International Nuclear Information System (INIS)

    Nitta, T.; Okada, T.

    1989-01-01

    This paper describes electrical transient characteristics of parallel running of the 20kVA superconducting synchronous generator and a conventional one. In the experimental power system, the superconducting generator is connected through reactors (artificial transmission lines) to a regional power system (infinite bus) and the conventional generator (20kVA) is connected to the terminal of the superconducting generator. Several tests were performed in order to consider the transient behavior of superconducting generator (SCG) in the power system. The items of the tests are synchronous closing test, loss of synchronism test and disconnecting and reclosing test. From the experimental results, it can be said that by installing SCG in power systems, voltage stability and power system stability can be improved in transient states as well as in steady states and the variation of armature current of SCG during a transient period is extremely larger than that of the conventional one. The transient analysis by a computer simulation was also carried out for the experiments. The simulation results are in good agreement with the experimental ones

  17. Electrical Rating of Concentrated Photovoltaic (CPV) Systems: Long-Term Performance Analysis and Comparison to Conventional PV Systems

    KAUST Repository

    Burhan, Muhammad

    2016-02-29

    The dynamic nature of meteorological data and the commercial availability of diverse photovoltaic systems, ranging from single-junction silicon-based PV panels to concentrated photovoltaic (CPV) systems utilizing multi-junction solar cells and a two-axis solar tracker, demand a simple but accurate methodology for energy planners and PV system designers to understand the economic feasibility of photovoltaic or renewable energy systems. In this paper, an electrical rating methodology is proposed that provides a common playing field for planners, consumers and PV manufacturers to evaluate the long-term performance of photovoltaic systems, as long-term electricity rating is deemed to be a quick and accurate method to evaluate economic viability and determine plant sizes and photovoltaic system power production. A long-term performance analysis based on monthly and electrical ratings (in kWh/m2/year) of two developed CPV prototypes, the Cassegrain mini dish and Fresnel lens CPVs with triple-junction solar cells operating under the meteorological conditions of Singapore, is presented in this paper. Performances are compared to other conventional photovoltaic systems.

  18. Safety classification of nuclear power plant systems, structures and components

    International Nuclear Information System (INIS)

    1992-01-01

    The Safety Classification principles used for the systems, structures and components of a nuclear power plant are detailed in the guide. For classification, the nuclear power plant is divided into structural and operational units called systems. Every structure and component under control is included into some system. The Safety Classes are 1, 2 and 3 and the Class EYT (non-nuclear). Instructions how to assign each system, structure and component to an appropriate safety class are given in the guide. The guide applies to new nuclear power plants and to the safety classification of systems, structures and components designed for the refitting of old nuclear power plants. The classification principles and procedures applying to the classification document are also given

  19. Power management for energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Gybel Hovgaard, T.

    2013-02-15

    In this thesis, we consider the control of two different industrial applications that belong at either end of the electricity grid; a power consumer in the form of a commercial refrigeration system, and wind turbines for power production. Our primary studies deal with economic model predictive control of a commercial multi-zone refrigeration system, consisting of several cooling units that share a common compressor, and is used to cool multiple areas or rooms, e.g., in supermarkets. For control of the commercial refrigeration application as well as the wind turbine application, we propose an economic optimizing model predictive controller, economic MPC. Our investigations are primarily concerned with: 1) modeling of the applications to suit the chosen control framework; 2) formulating the MPC controller laws to overcome challenges introduced by the industrial applications, and defining economic objectives that reect the real physics of the systems as well as our control objectives; 3) solving the involved, non-trivial optimization problems eciently in real-time; 4) demonstrating the feasibility and potential of the proposed methods by extensive simulation and comparison with existing control methods and evaluation of data from systems in actual operation. We demonstrate, i.a., substantial cost savings, on the order of 30 %, compared to a standard thermostat-based supermarket refrigeration system and show how our methods exhibit sophisticated demand response to real-time variations in electricity prices. Violations of the temperature ranges can be kept at a very low frequency of occurrence inspite of the presence of uncertainty. For the power output from wind turbines, ramp rates, as low a 3 % of the rated power per minute, can be effectively ensured with the use of energy storage and we show how the active use of rotor inertia as an additional energy storage can reduce the needed storage capacity by up to 30 % without reducing the power output. (Author)

  20. Dynamic Analysis & Characterization of Conventional Hydraulic Power Supply Units

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Liedhegener, Michael; Bech, Michael Møller

    2016-01-01

    Hydraulic power units operated as constant supply pres-sure systems remain to be widely used in the industry, to supply valve controlled hydraulic drives etc., where the hydraulic power units are constituted by variable pumps with mechanical outlet pressure control, driven by induction motors....... In the analysis of supplied drives, both linear and rotary, emphasis is commonly placed on the drives themselves and the related loads, and the supply system dynamics is often given only little attention, and usually neglected or taken into account in a simplified fashion. The simplified supply system dynamics...... and drives will reduce the flow-to-pressure gain of the supply system, and hence increase the time constant of the sup-ply pressure dynamics. A consequence of this may be large vari-ations in the supply pressure, hence large variations in the pump shaft torque, and thereby the induction motor load torque...

  1. Biologic and Conventional Systemic Therapies Show Similar Safety and Efficacy in Elderly and Adult Patients With Moderate to Severe Psoriasis.

    Science.gov (United States)

    Garber, Caren; Plotnikova, Natalia; Au, Shiu-chung; Sorensen, Eric P; Gottlieb, Alice

    2015-08-01

    safe and effective in the elderly and non-elderly cohorts. Within the elderly population, biologics may be a safer option than conventional systemic agents.

  2. Methods of computing steady-state voltage stability margins of power systems

    Science.gov (United States)

    Chow, Joe Hong; Ghiocel, Scott Gordon

    2018-03-20

    In steady-state voltage stability analysis, as load increases toward a maximum, conventional Newton-Raphson power flow Jacobian matrix becomes increasingly ill-conditioned so power flow fails to converge before reaching maximum loading. A method to directly eliminate this singularity reformulates the power flow problem by introducing an AQ bus with specified bus angle and reactive power consumption of a load bus. For steady-state voltage stability analysis, the angle separation between the swing bus and AQ bus can be varied to control power transfer to the load, rather than specifying the load power itself. For an AQ bus, the power flow formulation is only made up of a reactive power equation, thus reducing the size of the Jacobian matrix by one. This reduced Jacobian matrix is nonsingular at the critical voltage point, eliminating a major difficulty in voltage stability analysis for power system operations.

  3. Detection of Frauds and Other Non-technical Losses in Power Utilities using Smart Meters: A Review

    Science.gov (United States)

    Ahmad, Tanveer; Ul Hasan, Qadeer

    2016-06-01

    Analysis of losses in power distribution system and techniques to mitigate these are two active areas of research especially in energy scarce countries like Pakistan to increase the availability of power without installing new generation. Since total energy losses account for both technical losses (TL) as well as non-technical losses (NTLs). Utility companies in developing countries are incurring of major financial losses due to non-technical losses. NTLs lead to a series of additional losses, such as damage to the network (infrastructure and the reduction of network reliability) etc. The purpose of this paper is to perform an introductory investigation of non-technical losses in power distribution systems. Additionally, analysis of NTLs using consumer energy consumption data with the help of Linear Regression Analysis has been carried out. This data focuses on the Low Voltage (LV) distribution network, which includes: residential, commercial, agricultural and industrial consumers by using the monthly kWh interval data acquired over a period (one month) of time using smart meters. In this research different prevention techniques are also discussed to prevent illegal use of electricity in the distribution of electrical power system.

  4. Comparative evaluation of the anti-diabetic activity of Pterocarpus marsupium Roxb. heartwood in alloxan induced diabetic rats using extracts obtained by optimized conventional and non conventional extraction methods.

    Science.gov (United States)

    Devgan, Manish; Nanda, Arun; Ansari, Shahid Husain

    2013-09-01

    The aim of the present study was to assess the anti-diabetic activity of Pterocarpus marsupium Roxb. heartwood in alloxan induced diabetic rats using extracts obtained by optimized conventional and non conventional extraction methods. Aqueous and ethanol extracts of Pterocarpus marsupium heartwood were prepared by conventional methods (infusion, decoction, maceration and percolation) and non conventional methods, such as ultrasound-assisted extraction (UAE) and microwave-assisted extraction (MAE). The crude aqueous extracts were administered orally to both normal and alloxan induced male albino rats (Sprague-Dawley strain). The experimental set up consisted of 48 male albino rats divided into 6 groups: Normal control, diabetic control (sterile normal saline, 1 ml/100 g body weight), standard (gliclazide, 25 mg/1000g of body weight), groups 4-6 (crude aqueous percolation, optimized UAE and MAE extract, 250 mg/1000g of body weight). In acute treatment, the reduction of blood glucose level was statistically significant with the oral administration of UAE and percolation aqueous extracts to the hyperglycemic rats. In sub-acute treatment, the UAE aqueous extract led to consistent and statistically significant (p<0.001) reduction in the blood glucose levels. There was no abnormal change in body weight of the hyperglycemic animals after 10 days of administration of plant extracts and gliclazide. This study justifies the traditional claim and provides a rationale for the use of Pterocarpus marsupium to treat diabetes mellitus. The antidiabetic activity of Pterocarpus marsupium can be enhanced by extracting the heartwood by non conventional method of UAE.

  5. A "typodont" study of rate of orthodontic space closure: self-ligating systems vs. conventional systems.

    Science.gov (United States)

    Saporito, I; Butti, A C; Salvato, A; Biagi, R

    2011-01-01

    The aim of this study was to compare the effectiveness of space closure of two bracket systems, self-ligating and conventional ones, considering two systems with the same design and prescription. The experimental model of this study aims to identify in general if one type of system is more suitable for planning the extractive therapy, without considering the clinical aspect necessary for an adequate orthodontic approach. A resin maxilla without the first premolars was used to test the self-ligating and conventional brackets system. Space closure was achieved on 0.016x0.022" in stainless steel wires with nickel-titanium coil springs 150 grams in strength and 10 mm in length. Two experiment settings have been prepared. The first setting was made bonding conventional bracket on the right side and self-ligating on the left; the last one was made bonding self-ligating bracket on the right side and conventional on the left. All measurements (runs) have been repeated seven times for both settings. During the closing phase of extraction spaces both systems are equable since there are no significant statistical differences (P=0.70). Our typodont model showed no significant difference in the efficiency of space closure between the self-ligating bracket and conventional bracket tied with stainless steel ligatures.

  6. The power processor of a high temperature superconducting energy storage system

    Energy Technology Data Exchange (ETDEWEB)

    Ollila, J. [Power Electronics, Tampere University of Technology, Tampere (Finland)

    1997-12-31

    This report introduces the structure and properties of a power processor unit for a high temperature superconducting magnetic energy storage system which is bused in an UPS demonstration application. The operation is first demonstrated using simulations. The software based operating and control system utilising combined Delta-Sigma and Sliding-Mode control is described shortly. Preliminary test results using a conventional NbTi superconducting energy y storage magnet operating at 4.2 K is shown. (orig.)

  7. Nutritional Evaluation of Non-Conventional Vegetables in Brazil

    Directory of Open Access Journals (Sweden)

    LUIS FELIPE LIMA E SILVA

    2018-04-01

    Full Text Available ABSTRACT The objective of this study was to characterize the nutritional compounds of interest present in vegetables known as non-conventional, in Brazil. The following evaluations were carried out: antioxidant activity, phenolic compounds, vitamin C, calories, carbohydrates, humidity, lipids, proteins, fiber, acidity and quantification of minerals (P, K, Ca, Mg, S, Cu, Fe, Mn, Zn and B. The species studied were Amaranthus hybridus L., Amaranthus viridis L., Basella alba L., Eryngium campestre L., Hibiscus sabdariffa L., Lactuca canadensis L., Rumex acetosa L., Stachys byzantina K. Koch, Tropaeolum majus L. and Xanthosoma sagittifolium L. Representative samples of plant structures of interest were harvested from each species suitable for human consumption such as leaves, flowers and flower buds. The results were submitted to multivariate analysis - principal components analysis (PCA. All the species present nutritional compounds of interest in different levels among the evaluated structures.

  8. Wireless system controlling of electromagnetic wave distribution in nuclear power plant use

    International Nuclear Information System (INIS)

    Kuroda, Hidehiko; Kume, Naoto; Oshima, Tomomi; Takakura, Kei; Oda, Naotaka; Hasegawa, Takeshi; Odanaka, Shigeru

    2017-01-01

    Recently, wireless technologies have rapidly spread by cellular phones, smartphones and tablet devices. Wireless systems in the nuclear power plant are expected to bring various advantages such as shortening of the inspection time, online monitoring, remote control and cable reduction, etc. However, wireless systems have hardly applied to the nuclear power plant, from the point of security and electromagnetic interference (EMI). We propose a new wireless system controlling automatically electromagnetic wave distribution. In our wireless system, the transmitter / receiver modules automatically measure the wave strength and adjust the power and directivity of the wave, resulting in wireless communication only in target zones, i.e. non-influence to safety-related instruments and non-leakage of information. We will present the algorithm of the electromagnetic wave controlling and experimental results about the proposed system. (author)

  9. Working group 6: Health. 3. Biological effects of nonradioactive pollutants associated with nuclear and conventional power plants

    International Nuclear Information System (INIS)

    Lauwerys, R.

    1976-01-01

    The major air pollutants released from conventional power plants have been found to be sulfur dioxide (SO 2 ), nitrogen oxides (NOx) and suspended particulates beside these three major pollutants other substances (CO, O 3 , hydrocarbons, vanadium...) occur in air or in water. Origin and extent of these pollutants as well as their main health hazards, especially for the respiratory system, have been evaluated. Other risks connected with the whole fuel cycle (coal extraction, petrol refining...) have been considered to be significant for human health. A mathematical model has been set up by the C.E.N. of Mol (Belgium) in order to predict the content of pollutants at the soil level, especially for SO 2 . A relationship between SO 2 content and the concentration of the other pollutants has been found by assuming certain hypothesis. Epidemiological and toxicological data connected with the SO 2 release have been given. As for nonradioactive pollutants released from nuclear power plants their amount has been considered to be negligible. (G.C.)

  10. A new formalism for non extensive physical systems: Tsallis Thermo statistics

    International Nuclear Information System (INIS)

    Tirnakli, U.; Bueyuekkilic, F.; Demirhan, D.

    1999-01-01

    Although Boltzmann-Gibbs (BG) statistics provides a suitable tool which enables us to handle a large number of physical systems satisfactorily, it has some basic restrictions. Recently a non extensive thermo statistics has been proposed by C.Tsallis to handle the non extensive physical systems and up to now, besides the generalization of some of the conventional concepts, the formalism has been prosperous in some of the physical applications. In this study, our effort is to introduce Tsallis thermo statistics in some details and to emphasize its achievements on physical systems by noting the recent developments on this line

  11. Quantitative comparison of tumor vascularity of HCC after intravenous contrast Agent: Conventional versus harmonic power Doppler US

    International Nuclear Information System (INIS)

    Park, Seong Ho; Kim, Tae Kyoung; Lee, Kyoung Ho; Kim, Ah Young; Han, Joon Koo; Choi, Byung Ihn

    1999-01-01

    For the quantitative comparison of the degree of enhancement in nodular hepatocellular carcinoma (HCC) at conventional and harmonic Power Doppler (PD) ultrasound (US). The average of %PDA of ten nodules gradually increased until 60 seconds after contrast injection and then gradually decreased. The average %PDA on conventional and harmonic PD US at 60 seconds were 34.9% and 19.5%, respectively. The average %PDA were significantly higher on conventional PD US than those on harmonic PD US at all times except at 20 seconds. The ratio of average %pda on conventional PD US to those on harmonic PD US became gradually larger after 120 seconds. Although contrast-enhanced harmonic PD US can be an effective method in evaluating the tumor vascularity of HCC because of less PD artifacts, the duration of effective enhancement was shorter and degree of enhancement is less than that of conventional PD US.

  12. Limits to the Recognizability of Flaws in Non-Destructive Testing Steam-Generator Tubes for Nuclear-Power Plants

    International Nuclear Information System (INIS)

    Kuhlmann, A.; Adamsky, F.-J.

    1965-01-01

    In the Federal Republic of Germany there are nuclear reactors under construction with steam generators inside the reactor pressure-vessel. As a result design repairs of steam- generator tubes are very difficult and cause large shut-down times of the nuclear-power plant. It is known that numerous troubles in operating conventional power plants are results of steam-generator tube damages. Because of the high total costs of these reactors it. is necessary to construct the steam generators especially in such a manner that the load factor of the power plant is as high as possible. The Technischer Überwachungs-Verein Rheinland was charged to supervise and to test fabrication and construction of the steam generators to see that this part of the plant was as free of defects as possible. The experience gained during this work is of interest for manufacture and construction of steam generators for nuclear-power plants in general. This paper deals with the efficiency limits of non-destructive testing steam-generator tubes. The following tests performed will be discussed in detail: (a) Automatic ultrasonic testing of the straight tubes in the production facility; (b) Combined ultrasonic and radiographic testing of the bent tubes and tube weldings; (c) Other non-destructive tests. (author) [fr

  13. Power Consumption in Refrigeration Systems - Modeling for Optimization

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Larsen, Lars F. S.; Skovrup, Morten Juel

    2011-01-01

    Refrigeration systems consume a substantial amount of energy. Taking for instance supermarket refrigeration systems as an example they can account for up to 50−80% of the total energy consumption in the supermarket. Due to the thermal capacity made up by the refrigerated goods in the system...... there is a possibility for optimizing the power consumption by utilizing load shifting strategies. This paper describes the dynamics and the modeling of a vapor compression refrigeration system needed for sufficiently realistic estimation of the power consumption and its minimization. This leads to a non-convex function...... with possibly multiple extrema. Such a function can not directly be optimized by standard methods and a qualitative analysis of the system’s constraints is presented. The description of power consumption contains nonlinear terms which are approximated by linear functions in the control variables and the error...

  14. A non-canonical landscape of the microRNA system

    Directory of Open Access Journals (Sweden)

    Gabriel Adelman Cipolla

    2014-09-01

    Full Text Available Microribonucleic acids, best known as microRNAs or miRNAs, are small, non-coding RNAs with important regulatory roles in eukaryotic cells. Here, I present a broad review about highly relevant but generally non-depicted features of miRNAs, among which stand out the non-conventional miRNA seed sites, the unusual messenger RNA (mRNA target regions, the non-canonical miRNA-guided mechanisms of gene expression regulation and the recently identified new class of miRNA ligands. Furthermore, I address the miRNA uncommon genomic location, transcription, and subcellular localization. Altogether, these unusual features and roles place the miRNA system as a very diverse, complex and intriguing biological mechanism.

  15. Power system and market integration of renewable electricity

    Science.gov (United States)

    Erdmann, Georg

    2017-07-01

    This paper addresses problems of power generation markets that arise under high shares of intermittent generation. After discussing the economic fundamentals of wind and photovoltaic investments, the paper introduces the concept of the "Merit order effect of renewables". According to this concept electricity prices on wholesale power markets become smaller in periods during which large volumes of wind and photovoltaic generation is available and squeeze out relative expensive gas-fired power generation. The merit order effect of renewables has a couple of consequences. Among others it challenges the profitability of conventional power generation. If such generation capacities are still necessary, at least during a transitory period, a capacity mechanism may be put in place that generates an additional stream of income to the operators of conventional power generators. Another consequence of growing intermittent power generation is the need for concepts and technologies that deal with excess generation. Among these concepts are virtual and physical power storage capacities. In the last parts of the paper models are presented that are able to analyze these concepts from an economic point of view.

  16. A non-conventional interpretation of thermal regeneration in steam cycles

    International Nuclear Information System (INIS)

    Bracco, Stefano; Damiani, Lorenzo

    2012-01-01

    Highlights: ► A better understanding of the concept of thermal regeneration in steam cycles. ► Use of a system composed by a non-regenerative cycle and several reverse cycles. ► Calculation of the heat pumps coefficients of performance. ► New interesting formulations of the regenerative cycle efficiency. -- Abstract: The paper aims to contribute to a better understanding of the thermodynamic concept of heat regeneration in steam power plants with a finite number of bleedings. A regenerative Rankine cycle is compared to a complex system (CHC – complete hybrid cycle) composed by one non-regenerative Rankine cycle (HEC – hybrid engine cycle) and more reverse cycles (RCs – reverse cycles), as many as the number of the bleedings, able to pump heat from the condenser to a series of surface feedwater heaters, disposed upstream of the steam plant boiler. The COPs (coefficients of performance) of the heat pumps are evaluated, and new interesting formulations of the efficiency of the regenerative steam cycle are proposed. In particular a steam cycle with two bleedings is analyzed, neglecting heat losses and pressure drops in the boiler and considering irreversibility only along the expansion line of the steam turbine and into the feedwater heaters. The efficiency and the work of the regenerative cycle are compared to the analogous values of the CHC cycle composed by one simple steam cycle (HEC) and two heat pump cycles (RCs), with steam as the working fluid. The two reverse cycles are considered completely reversible and raising heat from the condenser temperature to the bled steam condensing temperature. The paper shows the most significant results of the study in order to analyze the regenerative cycle and the CHC cycle in comparison with the non-regenerative Rankine cycle; in particular, the analysis is focused on the evaluation of the useful work, the heat supplied and the heat rejected for the examined cycles.

  17. Field Trial on a Rack-mounted DC Power Supply System with 80-Ah Lithium-ion Batteries

    Science.gov (United States)

    Matsushima, Toshio

    Using an industrial lithium-ion battery that has higher energy density than conventional valve-regulated lead-acid batteries, a rack-mounted DC-power-supply system was assembled and tested at a base transceiver station (BTS) offering actual services. A nominal output voltage and maximum output current of the system is 53.5V and 20A, respectively. An 80-Ah lithium-ion battery composed of 13 cells connected in series was applied in the system and maintained in a floating charge method. The DC-power-supply system was installed in a 19-inch power rack in the telecommunications equipment box at BTS. The characteristics of the 80Ah lithium-ion battery, specifications of the DC-power-supply system and field-test results were shown in this paper.

  18. Assessment of HAPs emissions from advanced power systems

    International Nuclear Information System (INIS)

    Erickson, T.A.; Brekke, D.W.

    1996-01-01

    The 1990 Clean Air Act Amendments (CAAA) identified 189 substances as air toxics or hazardous air pollutants (HAPs). Under the CAAA, the U. S. Environmental Protection Agency (EPA) must regulate emissions of these HAPs at their sources, including advanced power systems used for the production of electricity. Eleven trace elements are included in the CAAA list of HAPS, as shown in Table 1. The EPA will define those sources that require regulation and limit their emissions according to regulatory directives. This project focused on evaluating and manipulating the advanced power systems HAPs data currently available for presentation to the U.S. Department of Energy (DOE). Trace components included in the 189 HAPs of the 1990 CAAA are: antimony compounds; arsenic compounds; beryllium compounds; cadmium compounds; chromium compounds; cobalt compounds; lead compounds; manganese compounds; mercury compounds; nickel compounds; and selenium compounds. The review of trace element emissions from advanced power systems and hot-gas cleanup systems included data from Tidd Station, General Electric hot-gas cleanup, Louisiana Gasification Technology Incorporated, and the Cool Water plant. Very few other sources of information were located, and those that were contained significantly flawed information that was not of value to this project. To offset the shortage of information, thermochemical equilibrium predictions were used in evaluating advanced control systems. An outline of the systems reviewed is given in Table 2. In addition to the four demonstration and 1 full-scale systems reviewed, nine conventional systems were also reviewed for comparison with the advanced systems

  19. SCEPS In Space - Non-Radioisotope Power Systems for Sunless Solar System Exploration Missions (Phase II)

    Data.gov (United States)

    National Aeronautics and Space Administration — Stored Chemical Energy Power Systems (SCEPS) have been used in U.S. Navy torpedos for decades. The Penn State Applied Research Lab proposes to continue the study of...

  20. Alternate seismic support for pipeline systems in nuclear power plants

    International Nuclear Information System (INIS)

    Muthumani, K.; Gopalakrishnan, N.; Sathish Kumar, K.; Sreekala, R.; Rama Rao, G.V.; Reddy, G.R.; Parulekar, Y.M.

    2008-01-01

    Failure free design of supporting systems for pipe lines carrying highly toxic or radioactive liquids at very high temperature is an important issue in the safety aspect for a nuclear power plant installation which is a key topic for researchers all around the world. Generally, these pipeline systems are designed to be held rigid by conventional snubber supports for protection from earthquakes. The piping design must balance seismic deformations and other deformations due to thermal effect. A rigid pipeline system using conventional snubber supports always leads to an increase in thermal stresses; hence a rational seismic design for pipeline supporting systems becomes essential. Contrary to this rigid design, it is possible to design a flexible pipeline system and to decrease the seismic response by increasing the damping through the use of passive energy absorbing elements, which dissipate vibration energy. This paper presents the experimental and analytical studies carried out on modeling yielding type elasto-plastic passive energy-absorbing elements to be used in a passive energy-dissipating device for the control of large seismic deformations of pipelines subjected to earthquake loading. (author)