WorldWideScience

Sample records for noise level reduction

  1. Adaptive EMG noise reduction in ECG signals using noise level approximation

    Science.gov (United States)

    Marouf, Mohamed; Saranovac, Lazar

    2017-12-01

    In this paper the usage of noise level approximation for adaptive Electromyogram (EMG) noise reduction in the Electrocardiogram (ECG) signals is introduced. To achieve the adequate adaptiveness, a translation-invariant noise level approximation is employed. The approximation is done in the form of a guiding signal extracted as an estimation of the signal quality vs. EMG noise. The noise reduction framework is based on a bank of low pass filters. So, the adaptive noise reduction is achieved by selecting the appropriate filter with respect to the guiding signal aiming to obtain the best trade-off between the signal distortion caused by filtering and the signal readability. For the evaluation purposes; both real EMG and artificial noises are used. The tested ECG signals are from the MIT-BIH Arrhythmia Database Directory, while both real and artificial records of EMG noise are added and used in the evaluation process. Firstly, comparison with state of the art methods is conducted to verify the performance of the proposed approach in terms of noise cancellation while preserving the QRS complex waves. Additionally, the signal to noise ratio improvement after the adaptive noise reduction is computed and presented for the proposed method. Finally, the impact of adaptive noise reduction method on QRS complexes detection was studied. The tested signals are delineated using a state of the art method, and the QRS detection improvement for different SNR is presented.

  2. Definition of 1992 Technology Aircraft Noise Levels and the Methodology for Assessing Airplane Noise Impact of Component Noise Reduction Concepts

    Science.gov (United States)

    Kumasaka, Henry A.; Martinez, Michael M.; Weir, Donald S.

    1996-01-01

    This report describes the methodology for assessing the impact of component noise reduction on total airplane system noise. The methodology is intended to be applied to the results of individual study elements of the NASA-Advanced Subsonic Technology (AST) Noise Reduction Program, which will address the development of noise reduction concepts for specific components. Program progress will be assessed in terms of noise reduction achieved, relative to baseline levels representative of 1992 technology airplane/engine design and performance. In this report, the 1992 technology reference levels are defined for assessment models based on four airplane sizes - an average business jet and three commercial transports: a small twin, a medium sized twin, and a large quad. Study results indicate that component changes defined as program final goals for nacelle treatment and engine/airframe source noise reduction would achieve from 6-7 EPNdB reduction of total airplane noise at FAR 36 Stage 3 noise certification conditions for all of the airplane noise assessment models.

  3. METHODS OF NOISE LEVEL REDUCTION OF DRIVE IN LATHES

    Directory of Open Access Journals (Sweden)

    Janusz ROGULA

    2014-06-01

    Full Text Available The aim of this work is method presentation to noise level reduction of fixed headstock of the lathe. It is connected with the causes finding of non-uniform work of lathe headstock, description of recent design and its analysis. Problem of the excessive noise level concern to near 35% of the lathes have been produced. In spite of lack of noise reduction possibility there were no system solution of problem. Design optimisation weren’t done after application the electric motor with inverter. New solution of electric motor control let to reduce number of gear wheels in lathe drive system. For this drive solution there weren’t made the analysis of drive particular parts influence on the noise generation.

  4. Critical Low-Noise Technologies Being Developed for Engine Noise Reduction Systems Subproject

    Science.gov (United States)

    Grady, Joseph E.; Civinskas, Kestutis C.

    2004-01-01

    NASA's previous Advanced Subsonic Technology (AST) Noise Reduction Program delivered the initial technologies for meeting a 10-year goal of a 10-dB reduction in total aircraft system noise. Technology Readiness Levels achieved for the engine-noise-reduction technologies ranged from 4 (rig scale) to 6 (engine demonstration). The current Quiet Aircraft Technology (QAT) project is building on those AST accomplishments to achieve the additional noise reduction needed to meet the Aerospace Technology Enterprise's 10-year goal, again validated through a combination of laboratory rig and engine demonstration tests. In order to meet the Aerospace Technology Enterprise goal for future aircraft of a 50- reduction in the perceived noise level, reductions of 4 dB are needed in both fan and jet noise. The primary objectives of the Engine Noise Reduction Systems (ENRS) subproject are, therefore, to develop technologies to reduce both fan and jet noise by 4 dB, to demonstrate these technologies in engine tests, and to develop and experimentally validate Computational Aero Acoustics (CAA) computer codes that will improve our ability to predict engine noise.

  5. Occupational Noise Reduction in CNC Striping Process

    Science.gov (United States)

    Mahmad Khairai, Kamarulzaman; Shamime Salleh, Nurul; Razlan Yusoff, Ahmad

    2018-03-01

    Occupational noise hearing loss with high level exposure is common occupational hazards. In CNC striping process, employee that exposed to high noise level for a long time as 8-hour contributes to hearing loss, create physical and psychological stress that reduce productivity. In this paper, CNC stripping process with high level noises are measured and reduced to the permissible noise exposure. First condition is all machines shutting down and second condition when all CNC machine under operations. For both conditions, noise exposures were measured to evaluate the noise problems and sources. After improvement made, the noise exposures were measured to evaluate the effectiveness of reduction. The initial average noise level at the first condition is 95.797 dB (A). After the pneumatic system with leakage was solved, the noise reduced to 55.517 dB (A). The average noise level at the second condition is 109.340 dB (A). After six machines were gathered at one area and cover that area with plastic curtain, the noise reduced to 95.209 dB (A). In conclusion, the noise level exposure in CNC striping machine is high and exceed the permissible noise exposure can be reduced to acceptable levels. The reduction of noise level in CNC striping processes enhanced productivity in the industry.

  6. Active3 noise reduction

    International Nuclear Information System (INIS)

    Holzfuss, J.

    1996-01-01

    Noise reduction is a problem being encountered in a variety of applications, such as environmental noise cancellation, signal recovery and separation. Passive noise reduction is done with the help of absorbers. Active noise reduction includes the transmission of phase inverted signals for the cancellation. This paper is about a threefold active approach to noise reduction. It includes the separation of a combined source, which consists of both a noise and a signal part. With the help of interaction with the source by scanning it and recording its response, modeling as a nonlinear dynamical system is achieved. The analysis includes phase space analysis and global radial basis functions as tools for the prediction used in a subsequent cancellation procedure. Examples are given which include noise reduction of speech. copyright 1996 American Institute of Physics

  7. The effects of noise reduction technologies on the acceptance of background noise.

    Science.gov (United States)

    Lowery, Kristy Jones; Plyler, Patrick N

    2013-09-01

    Directional microphones (D-Mics) and digital noise reduction (DNR) algorithms are used in hearing aids to reduce the negative effects of background noise on performance. Directional microphones attenuate sounds arriving from anywhere other than the front of the listener while DNR attenuates sounds with physical characteristics of noise. Although both noise reduction technologies are currently available in hearing aids, it is unclear if the use of these technologies in isolation or together affects acceptance of noise and/or preference for the end user when used in various types of background noise. The purpose of the research was to determine the effects of D-Mic, DNR, or the combination of D-Mic and DNR on acceptance of noise and preference when listening in various types of background noise. An experimental study in which subjects were exposed to a repeated measures design was utilized. Thirty adult listeners with mild sloping to moderately severe sensorineural hearing loss participated (mean age 67 yr). Acceptable noise levels (ANLs) were obtained using no noise reduction technologies, D-Mic only, DNR only, and the combination of the two technologies (Combo) for three different background noises (single-talker speech, speech-shaped noise, and multitalker babble) for each listener. In addition, preference rankings of the noise reduction technologies were obtained within each background noise (1 = best, 3 = worst). ANL values were significantly better for each noise reduction technology than baseline; and benefit increased significantly from DNR to D-Mic to Combo. Listeners with higher (worse) baseline ANLs received more benefit from noise reduction technologies than listeners with lower (better) baseline ANLs. Neither ANL values nor ANL benefit values were significantly affected by background noise type; however, ANL benefit with D-Mic and Combo was similar when speech-like noise was present while ANL benefit was greatest for Combo when speech spectrum noise was

  8. Helicopter Flight Procedures for Community Noise Reduction

    Science.gov (United States)

    Greenwood, Eric

    2017-01-01

    A computationally efficient, semiempirical noise model suitable for maneuvering flight noise prediction is used to evaluate the community noise impact of practical variations on several helicopter flight procedures typical of normal operations. Turns, "quick-stops," approaches, climbs, and combinations of these maneuvers are assessed. Relatively small variations in flight procedures are shown to cause significant changes to Sound Exposure Levels over a wide area. Guidelines are developed for helicopter pilots intended to provide effective strategies for reducing the negative effects of helicopter noise on the community. Finally, direct optimization of flight trajectories is conducted to identify low noise optimal flight procedures and quantify the magnitude of community noise reductions that can be obtained through tailored helicopter flight procedures. Physically realizable optimal turns and approaches are identified that achieve global noise reductions of as much as 10 dBA Sound Exposure Level.

  9. REDUCTION OF CLASSROOM NOISE LEVELS USING GROUP CONTINGENCIES

    OpenAIRE

    Ring, Brandon M.; Sigurdsson, Sigurdur O.; Eubanks, Sean L.; Silverman, Kenneth

    2014-01-01

    The therapeutic workplace is an employment-based abstinence reinforcement intervention for unemployed drug users where trainees receive on-the-job employment skills training in a classroom setting. The study is an extension of prior therapeutic workplace research, which suggested that trainees frequently violated noise standards. Participants received real-time graphed feedback of noise levels and had the opportunity to earn monetary group reinforcement for maintaining a low number of noise v...

  10. Noise and Fuel Burn Reduction Potential of an Innovative Subsonic Transport Configuration

    Science.gov (United States)

    Guo, Yueping; Nickol, Craig L.; Thomas, Russell H.

    2014-01-01

    A study is presented for the noise and fuel burn reduction potential of an innovative double deck concept aircraft with two three-shaft direct-drive turbofan engines. The engines are mounted from the fuselage so that the engine inlet is over the main wing. It is shown that such an aircraft can achieve a cumulative Effective Perceived Noise Level (EPNL) about 28 dB below the current aircraft noise regulations of Stage 4. The combination of high bypass ratio engines and advanced wing design with laminar flow control technologies provide fuel burn reduction and low noise levels simultaneously. For example, the fuselage mounted engine position provides more than 4 EPNLdB of noise reduction by shielding the inlet radiated noise. To identify the potential effect of noise reduction technologies on this concept, parametric studies are presented to reveal the system level benefits of various emerging noise reduction concepts, for both engine and airframe noise reduction. These concepts are discussed both individually to show their respective incremental noise reduction potential and collectively to assess their aggregate effects on the total noise. Through these concepts approximately about 8 dB of additional noise reduction is possible, bringing the cumulative noise level of this aircraft to 36 EPNLdB below Stage 4, if the entire suite of noise reduction technologies would mature to practical application. In a final step, an estimate is made for this same aircraft concept but with higher bypass ratio, geared, turbofan engines. With this geared turbofan propulsion system, the noise is estimated to reach as low as 40-42 dB below Stage 4 with a fuel burn reduction of 43-47% below the 2005 best-in-class aircraft baseline. While just short of the NASA N+2 goals of 42 dB and 50% fuel burn reduction, for a 2025 in service timeframe, this assessment shows that this innovative concept warrants refined study. Furthermore, this design appears to be a viable potential future passenger

  11. Advanced supersonic propulsion study. [with emphasis on noise level reduction

    Science.gov (United States)

    Sabatella, J. A. (Editor)

    1974-01-01

    A study was conducted to determine the promising propulsion systems for advanced supersonic transport application, and to identify the critical propulsion technology requirements. It is shown that noise constraints have a major effect on the selection of the various engine types and cycle parameters. Several promising advanced propulsion systems were identified which show the potential of achieving lower levels of sideline jet noise than the first generation supersonic transport systems. The non-afterburning turbojet engine, utilizing a very high level of jet suppression, shows the potential to achieve FAR 36 noise level. The duct-heating turbofan with a low level of jet suppression is the most attractive engine for noise levels from FAR 36 to FAR 36 minus 5 EPNdb, and some series/parallel variable cycle engines show the potential of achieving noise levels down to FAR 36 minus 10 EPNdb with moderate additional penalty. The study also shows that an advanced supersonic commercial transport would benefit appreciably from advanced propulsion technology. The critical propulsion technology needed for a viable supersonic propulsion system, and the required specific propulsion technology programs are outlined.

  12. Aircraft Noise Reduction Subproject Overview

    Science.gov (United States)

    Fernandez, Hamilton; Nark, Douglas M.; Van Zante, Dale E.

    2016-01-01

    The material presents highlights of propulsion and airframe noise research being completed for the Advanced Air Transport Technology Project. The basis of noise reduction plans along with representative work for the airframe, propulsion, and propulsion-airframe integration is discussed for the Aircraft Noise reduction Subproject.

  13. Digitally controlled active noise reduction with integrated speech communication

    NARCIS (Netherlands)

    Steeneken, H.J.M.; Verhave, J.A.

    2004-01-01

    Active noise reduction is a successful addition to passive ear-defenders for improvement of the sound attenuation at low frequencies. Design and assessment methods are discussed, focused on subjective and objective attenuation measurements, stability, and high noise level applications. Active noise

  14. The impact of a noise reduction quality improvement project upon sound levels in the open-unit-design neonatal intensive care unit.

    Science.gov (United States)

    Liu, W F

    2010-07-01

    To decrease measured sound levels in the neonatal intensive care unit through implementation of human factor and minor design modification strategies. Prospective time series. Two open-unit-design neonatal centers. Implementation of a coordinated program of noise reduction strategies did not result in any measurable improvement in levels of loudness or quiet. Two centers, using primarily human behavior noise reduction strategies, were unable to demonstrate measurable improvements in sound levels within the occupied open-unit-design neonatal intensive care unit.

  15. Spreadsheet tool for estimating noise reduction costs

    International Nuclear Information System (INIS)

    Frank, L.; Senden, V.; Leszczynski, Y.

    2009-01-01

    The Northeast Capital Industrial Association (NCIA) represents industry in Alberta's industrial heartland. The organization is in the process of developing a regional noise management plan (RNMP) for their member companies. The RNMP includes the development of a noise reduction cost spreadsheet tool to conduct reviews of practical noise control treatments available for individual plant equipment, inclusive of ranges of noise attenuation achievable, which produces a budgetary prediction of the installed cost of practical noise control treatments. This paper discussed the noise reduction cost spreadsheet tool, with particular reference to noise control best practices approaches and spreadsheet tool development such as prerequisite, assembling data required, approach, and unit pricing database. Use and optimization of the noise reduction cost spreadsheet tool was also discussed. It was concluded that the noise reduction cost spreadsheet tool is an easy interactive tool to estimate implementation costs related to different strategies and options of noise control mitigating measures and was very helpful in gaining insight for noise control planning purposes. 2 tabs.

  16. Noise Reduction Effect of Multiple-Sampling-Based Signal-Readout Circuits for Ultra-Low Noise CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Shoji Kawahito

    2016-11-01

    Full Text Available This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs. This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC. The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median: 0.29 e−rms when compared with the CMS gain of two (2.4 e−rms, or 16 (1.1 e−rms.

  17. 40 CFR 211.207 - Computation of the noise -reduction rating (NRR).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Computation of the noise -reduction... of the noise -reduction rating (NRR). Calculate the NRR for hearing protective devices by... “A”-weighting relative response corrections applied to any sound levels at the indicated octave band...

  18. Jet noise reduction via dispersed phase injection

    Science.gov (United States)

    Greska, Brent; Krothapalli, Anjaneyulu; Arakeri, Vijay

    2001-11-01

    A recently developed hot jet aeroacoustics facility at FMRL,FAMU-FSU College of Engineering has been used to study the far field noise characteristics of hot supersonic jets as influenced by the injection of a dispersed phase with low mass loading.The measured SPL from a fully expanded Mach 1.36 hot jet shows a peak value of about 139 dB at 40 deg from the jet axis.By injecting atomized water,the SPL are reduced in the angular region of about 30 deg to 50 deg with the maximum reduction being about 2 dB at 40 deg.However,with the use of non atomized aqueous polymer solution as a dispersed phase the noise levels are reduced over all angular positions by at least 1 dB with the maximum reduction being about 3 dB at 40 deg.The injection of a dispersed phase readily kills the screech; the initial results show promise and optimization studies are underway to find methods of further noise reduction.

  19. Reduction of Altitude Diffuser Jet Noise Using Water Injection

    Science.gov (United States)

    Allgood, Daniel C.; Saunders, Grady P.; Langford, Lester A.

    2011-01-01

    A feasibility study on the effects of injecting water into the exhaust plume of an altitude rocket diffuser for the purpose of reducing the far-field acoustic noise has been performed. Water injection design parameters such as axial placement, angle of injection, diameter of injectors, and mass flow rate of water have been systematically varied during the operation of a subscale altitude test facility. The changes in acoustic far-field noise were measured with an array of free-field microphones in order to quantify the effects of the water injection on overall sound pressure level spectra and directivity. The results showed significant reductions in noise levels were possible with optimum conditions corresponding to water injection at or just upstream of the exit plane of the diffuser. Increasing the angle and mass flow rate of water injection also showed improvements in noise reduction. However, a limit on the maximum water flow rate existed as too large of flow rate could result in un-starting the supersonic diffuser.

  20. Potential for Landing Gear Noise Reduction on Advanced Aircraft Configurations

    Science.gov (United States)

    Thomas, Russell H.; Nickol, Craig L.; Burley, Casey L.; Guo, Yueping

    2016-01-01

    The potential of significantly reducing aircraft landing gear noise is explored for aircraft configurations with engines installed above the wings or the fuselage. An innovative concept is studied that does not alter the main gear assembly itself but does shorten the main strut and integrates the gear in pods whose interior surfaces are treated with acoustic liner. The concept is meant to achieve maximum noise reduction so that main landing gears can be eliminated as a major source of airframe noise. By applying this concept to an aircraft configuration with 2025 entry-into-service technology levels, it is shown that compared to noise levels of current technology, the main gear noise can be reduced by 10 EPNL dB, bringing the main gear noise close to a floor established by other components such as the nose gear. The assessment of the noise reduction potential accounts for design features for the advanced aircraft configuration and includes the effects of local flow velocity in and around the pods, gear noise reflection from the airframe, and reflection and attenuation from acoustic liner treatment on pod surfaces and doors. A technical roadmap for maturing this concept is discussed, and the possible drag increase at cruise due to the addition of the pods is identified as a challenge, which needs to be quantified and minimized possibly with the combination of detailed design and application of drag reduction technologies.

  1. Noise level in a pediatric intensive care unit.

    Science.gov (United States)

    Carvalho, Werther B; Pedreira, Mavilde L G; de Aguiar, Maria Augusta L

    2005-01-01

    The purpose of this study was to verify the noise level at a PICU. This prospective observational study was performed in a 10 bed PICU at a teaching hospital located in a densely populated district within the city of São Paulo, Brazil. Sound pressure levels (dBA) were measured 24 hours during a 6-day period. Noise recording equipment was placed in the PICU access corridor, nursing station, two open wards with three and five beds, and in isolation rooms. The resulting curves were analyzed. A basal noise level variation between 60 and 70 dBA was identified, with a maximum level of 120 dBA. The most significant noise levels were recorded during the day and were produced by the staff. The basal noise level identified exceeds International Noise Council recommendations. Education regarding the effects of noise on human hearing and its relation to stress is the essential basis for the development of a noise reduction program.

  2. Experimental Study of Wake / Flap Interaction Noise and the Reduction of Flap Side Edge Noise

    Science.gov (United States)

    Hutcheson, Florence V.; Stead, Daniel J.; Plassman, Gerald E.

    2016-01-01

    The effects of the interaction of a wake with a half-span flap on radiated noise are examined. The incident wake is generated by bars of various widths and lengths or by a simplified landing gear model. Single microphone and phased array measurements are used to isolate the effects of the wake interaction on the noise radiating from the flap side edge and flap cove regions. The effects on noise of the wake generator's geometry and relative placement with respect to the flap are assessed. Placement of the wake generators upstream of the flap side edge is shown to lead to the reduction of flap side edge noise by introducing a velocity deficit and likely altering the instabilities in the flap side edge vortex system. Significant reduction in flap side edge noise is achieved with a bar positioned directly upstream of the flap side edge. The noise reduction benefit is seen to improve with increased bar width, length and proximity to the flap edge. Positioning of the landing gear model upstream of the flap side edge also leads to decreased flap side edge noise. In addition, flap cove noise levels are significantly lower than when the landing gear is positioned upstream of the flap mid-span. The impact of the local flow velocity on the noise radiating directly from the landing gear is discussed. The effects of the landing gear side-braces on flap side edge, flap cove and landing gear noise are shown.

  3. Market Analysis of Soundproof and Noise Reduction Plate

    Directory of Open Access Journals (Sweden)

    Chang Heyu

    2017-01-01

    Full Text Available Since the reform and opening up, China has a booming economy development, transportation industry as an important part of the economic processes has made a considerable progress, and continue to promote the rapid economic development. At the end of 2012, China's highway mileage has reached 4.238 million km and highway mileage ranks first in the world. Transportation in promoting rapid economic development, but also brings the traffic noise which has a tremendous influence on residents’ daily life, and this influence has gradually deepening and widening, in this situation the production of noise reduction panel gradually emerged. In this paper, a noise barriers manufacturer’ business model in Beijing Daxing District and analyze existing data will be analyzed, it will give much guidance and reference for a new noise reduction factory. The study has shown that plant will target all levels of government departments in charge of roads and the property of management department of residence as our customer groups, increasing technological innovation and improving product quality to establish a more extensive business relationships, and gradually formed noise barriers market competitiveness.

  4. A conceptual framework for noise reduction

    CERN Document Server

    Benesty, Jacob

    2015-01-01

    Though noise reduction and speech enhancement problems have been studied for at least five decades, advances in our understanding and the development of reliable algorithms are more important than ever, as they support the design of tailored solutions for clearly defined applications. In this work, the authors propose a conceptual framework that can be applied to the many different aspects of noise reduction, offering a uniform approach to monaural and binaural noise reduction problems, in the time domain and in the frequency domain, and involving a single or multiple microphones. Moreover, the derivation of optimal filters is simplified, as are the performance measures used for their evaluation.

  5. Jet Noise Reduction by Microjets - A Parametric Study

    Science.gov (United States)

    Zaman, K. B. M. Q.

    2010-01-01

    The effect of injecting tiny secondary jets (microjets ) on the radiated noise from a subsonic primary jet is studied experimentally. The microjets are injected on to the primary jet near the nozzle exit with variable port geometry, working fluid and driving pressure. A clear noise reduction is observed that improves with increasing jet pressure. It is found that smaller diameter ports with higher driving pressure, but involving less thrust and mass fraction, can produce better noise reduction. A collection of data from the present as well as past experiments is examined in an attempt to correlate the noise reduction with the operating parameters. The results indicate that turbulent mixing noise reduction, as monitored by OASPL at a shallow angle, correlates with the ratio of jet to primary jet driving pressures normalized by the ratio of corresponding diameters (p d /pjD). With gaseous injection, the spectral amplitudes decrease at lower frequencies while an increase is noted at higher frequencies. It is apparent that this amplitude crossover is at least partly due to shock-associated noise from the underexpanded jets themselves. Such crossover is not seen with water injection since the flow in that case is incompressible and there is no shock-associated noise. Centerline velocity data show that larger noise reduction is accompanied by faster jet decay as well as significant reduction in turbulence intensities. While a physical understanding of the dependence of noise reduction on p d /pjD remains unclear, given this correlation, an analysis explains the observed dependence of the effect on various other parameters.

  6. Prewhitening for Rank-Deficient Noise in Subspace Methods for Noise Reduction

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Søren Holdt

    2005-01-01

    A fundamental issue in connection with subspace methods for noise reduction is that the covariance matrix for the noise is required to have full rank, in order for the prewhitening step to be defined. However, there are important cases where this requirement is not fulfilled, e.g., when the noise...... has narrow-band characteristics, or in the case of tonal noise. We extend the concept of prewhitening to include the case when the noise covariance matrix is rank deficient, using a weighted pseudoinverse and the quotient SVD, and we show how to formulate a general rank-reduction algorithm that works...... also for rank deficient noise. We also demonstrate how to formulate this algorithm by means of a quotient ULV decomposition, which allows for faster computation and updating. Finally we apply our algorithm to a problem involving a speech signal contaminated by narrow-band noise....

  7. Noise Reduction with Microphone Arrays for Speaker Identification

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Z

    2011-12-22

    Reducing acoustic noise in audio recordings is an ongoing problem that plagues many applications. This noise is hard to reduce because of interfering sources and non-stationary behavior of the overall background noise. Many single channel noise reduction algorithms exist but are limited in that the more the noise is reduced; the more the signal of interest is distorted due to the fact that the signal and noise overlap in frequency. Specifically acoustic background noise causes problems in the area of speaker identification. Recording a speaker in the presence of acoustic noise ultimately limits the performance and confidence of speaker identification algorithms. In situations where it is impossible to control the environment where the speech sample is taken, noise reduction filtering algorithms need to be developed to clean the recorded speech of background noise. Because single channel noise reduction algorithms would distort the speech signal, the overall challenge of this project was to see if spatial information provided by microphone arrays could be exploited to aid in speaker identification. The goals are: (1) Test the feasibility of using microphone arrays to reduce background noise in speech recordings; (2) Characterize and compare different multichannel noise reduction algorithms; (3) Provide recommendations for using these multichannel algorithms; and (4) Ultimately answer the question - Can the use of microphone arrays aid in speaker identification?

  8. Noise reduction and estimation in multiple micro-electro-mechanical inertial systems

    International Nuclear Information System (INIS)

    Waegli, Adrian; Skaloud, Jan; Guerrier, Stéphane; Parés, Maria Eulàlia; Colomina, Ismael

    2010-01-01

    This research studies the reduction and the estimation of the noise level within a redundant configuration of low-cost (MEMS-type) inertial measurement units (IMUs). Firstly, independent observations between units and sensors are assumed and the theoretical decrease in the system noise level is analyzed in an experiment with four MEMS-IMU triads. Then, more complex scenarios are presented in which the noise level can vary in time and for each sensor. A statistical method employed for studying the volatility of financial markets (GARCH) is adapted and tested for the usage with inertial data. This paper demonstrates experimentally and through simulations the benefit of direct noise estimation in redundant IMU setups

  9. Noise reduction in the beam current monitor

    International Nuclear Information System (INIS)

    Arai, Shigeaki.

    1982-02-01

    A simple noise reduction system using a pulse transformer and a pair of L C low pass filters has been introduced to the beam current monitor of a current transformer type at the INS electron linac. With this system, the pick-up noise has been reduced to be 1% of the noise without noise reduction. Signal deformation caused by this system is relatively small and the beam current pulse down to 20 mA is successfully monitored in the actual accelerator operation. (author)

  10. Research on Noise Reduction of Reed Valves of a Hermetic Refrigerator Compressor

    Science.gov (United States)

    He, Zhilong; Chen, Qian; Li, Dantong; Wang, Ju; Xia, Pu; Wang, Tao

    2017-08-01

    The noise level of the refrigerator compressor has received more and more attention in recent years. As the key component of a compressor, reed valve is its main noise source. In this paper, a new noise reduction technology of coating on reed valve surface is proposed and verified by experiments. Firstly, the reed valves were coated, and their surface characteristics were checked. Then, the refrigerator compressor p-V diagram test was carried out to investigate the influence of doped diamond-like carbon (DLC) coating on power consumption. Finally, the noise test rig for the refrigerator compressor was set up. Based on the standard test method, noise spectrum was measured in a semi-anechoic room under standard working condition. Research results showed that the compressor noise was significantly reduced by 1.8dB (A) after coating. Moreover, the effect of aerodynamic noise reduction at suction side is better than that at discharge side. However, the influence of the film thickness on noise reduction value is little. The COP was reduced by 0.6% as compared to the compressor with uncoated reed valves.

  11. Compressed air noise reductions from using advanced air gun nozzles in research and development environments.

    Science.gov (United States)

    Prieve, Kurt; Rice, Amanda; Raynor, Peter C

    2017-08-01

    The aims of this study were to evaluate sound levels produced by compressed air guns in research and development (R&D) environments, replace conventional air gun models with advanced noise-reducing air nozzles, and measure changes in sound levels to assess the effectiveness of the advanced nozzles as engineering controls for noise. Ten different R&D manufacturing areas that used compressed air guns were identified and included in the study. A-weighted sound level and Z-weighted octave band measurements were taken simultaneously using a single instrument. In each area, three sets of measurements, each lasting for 20 sec, were taken 1 m away and perpendicular to the air stream of the conventional air gun while a worker simulated typical air gun work use. Two different advanced noise-reducing air nozzles were then installed. Sound level and octave band data were collected for each of these nozzles using the same methods as for the original air guns. Both of the advanced nozzles provided sound level reductions of about 7 dBA, on average. The highest noise reductions measured were 17.2 dBA for one model and 17.7 dBA for the other. In two areas, the advanced nozzles yielded no sound level reduction, or they produced small increases in sound level. The octave band data showed strong similarities in sound level among all air gun nozzles within the 10-1,000 Hz frequency range. However, the advanced air nozzles generally had lower noise contributions in the 1,000-20,000 Hz range. The observed decreases at these higher frequencies caused the overall sound level reductions that were measured. Installing new advanced noise-reducing air nozzles can provide large sound level reductions in comparison to existing conventional nozzles, which has direct benefit for hearing conservation efforts.

  12. Principal Components as a Data Reduction and Noise Reduction Technique

    Science.gov (United States)

    Imhoff, M. L.; Campbell, W. J.

    1982-01-01

    The potential of principal components as a pipeline data reduction technique for thematic mapper data was assessed and principal components analysis and its transformation as a noise reduction technique was examined. Two primary factors were considered: (1) how might data reduction and noise reduction using the principal components transformation affect the extraction of accurate spectral classifications; and (2) what are the real savings in terms of computer processing and storage costs of using reduced data over the full 7-band TM complement. An area in central Pennsylvania was chosen for a study area. The image data for the project were collected using the Earth Resources Laboratory's thematic mapper simulator (TMS) instrument.

  13. Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography

    International Nuclear Information System (INIS)

    Shen, Junlin; Du, Xiangying; Guo, Daode; Cao, Lizhen; Gao, Yan; Bai, Mei; Li, Pengyu; Liu, Jiabin; Li, Kuncheng

    2013-01-01

    Purpose: To investigate the potential of noise-based tube current reduction method with iterative reconstruction to reduce radiation exposure while achieving consistent image quality in coronary CT angiography (CCTA). Materials and methods: 294 patients underwent CCTA on a 64-detector row CT equipped with iterative reconstruction. 102 patients with fixed tube current were assigned to Group 1, which was used to establish noise-based tube current modulation formulas, where tube current was modulated by the noise of test bolus image. 192 patients with noise-based tube current were randomly assigned to Group 2 and Group 3. Filtered back projection was applied for Group 2 and iterative reconstruction for Group 3. Qualitative image quality was assessed with a 5 point score. Image noise, signal intensity, volume CT dose index, and dose-length product were measured. Results: The noise-based tube current modulation formulas were established through regression analysis using image noise measurements in Group 1. Image noise was precisely maintained at the target value of 35.00 HU with small interquartile ranges for Group 2 (34.17–35.08 HU) and Group 3 (34.34–35.03 HU), while it was from 28.41 to 36.49 HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 14% and 41% reduction in effective dose for Group 2 and Group 3 were observed compared with Group 1. Conclusion: Adequate image quality could be maintained at a desired and consistent noise level with overall 14% dose reduction using noise-based tube current reduction method. The use of iterative reconstruction further achieved approximately 40% reduction in effective dose

  14. SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

    Energy Technology Data Exchange (ETDEWEB)

    Maitree, R; Guzman, G; Chundury, A; Roach, M; Yang, D [Washington University School of Medicine, St Louis, MO (United States)

    2016-06-15

    Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness of available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and

  15. SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

    International Nuclear Information System (INIS)

    Maitree, R; Guzman, G; Chundury, A; Roach, M; Yang, D

    2016-01-01

    Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness of available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and

  16. Pilot survey of subway and bus stop noise levels.

    Science.gov (United States)

    Gershon, Robyn R M; Neitzel, Richard; Barrera, Marissa A; Akram, Muhammad

    2006-09-01

    Excessive noise exposure is a serious global urban health problem, adversely affecting millions of people. One often cited source of urban noise is mass transit, particularly subway systems. As a first step in determining risk within this context, we recently conducted an environmental survey of noise levels of the New York City transit system. Over 90 noise measurements were made using a sound level meter. Average and maximum noise levels were measured on subway platforms, and maximum levels were measured inside subway cars and at several bus stops for comparison purposes. The average noise level measured on the subway platforms was 86 +/- 4 dBA (decibel-A weighting). Maximum levels of 106, 112, and 89 dBA were measured on subway platforms, inside subway cars, and at bus stops, respectively. These results indicate that noise levels in subway and bus stop environments have the potential to exceed recommended exposure guidelines from the World Health Organization (WHO) and U.S. Environmental Protection Agency (EPA), given sufficient exposure duration. Risk reduction strategies following the standard hierarchy of control measures should be applied, where feasible, to reduce subway noise exposure.

  17. Investigating impact of motor oil quality on vehicles engine induced noise level

    Directory of Open Access Journals (Sweden)

    I. Arefian

    2015-09-01

    Full Text Available Introduction: Vehicle engine id one of the main sources of noise which its level is influenced by various parameters. The aim of this study was to investigate the impact of motor oils quality before and after oil change on the variability of vehicle engine induced noise level. In this study it is tried to follow-up the efficacy of motor oil quality on engines sound level. Material and Method: First, engine noise of 94 vehicles were recorded for 30 seconds before and after oil change and all the vehicles technical information including mileage, type of motor oil, and type of vehicle were registered. Following, the recorded noises were calibrated in semi-anechoic chamber and the sound pressure levels were measured with A and C-weighting network and main octav bands, using a sound level meters. The obtained results analyzed using SPSS software version 17. Results: The effects of motor oil quality on different noise levels of engines were determined and a significant reduction in noise level of vehicles engine was observed. Investigation of the relationship between mileage and motor oil quality on various engines sound level manifested that vehicles with mileage ranged 100000-150000 miles had significant reduction in their sound pressure levels in comparison with other vehicles. Conclusion: The results revealed that engine oil is among factors reducing the vehicle engine induced noise level. Moreover, the engine oil type and the vehicle mileage are key variables which determine the impact of engine oil quality on reduction of the sound level of vehicles engine.

  18. Reduction of HCCI combustion noise through piston crown design

    DEFF Research Database (Denmark)

    Pedersen, Troels Dyhr; Schramm, Jesper

    2010-01-01

    . The largest and most consistent reduction in noise level was however achieved with a diesel bowl type piston. The increased surface area as well as the larger crevice volumes of the experimental piston crowns generally resulted in lower IMEP than the flat piston. While the crevice volumes can be reduced...... away from the engine. The experiments were conducted in a diesel engine that was run in HCCI combustion mode with a fixed quantity of DME as fuel. The results show that combustion knock is effectively suppressed by limiting the size of the volume in which the combustion occurs. Splitting...... the compression volume into four smaller volumes placed between the perimeter of the piston and the cylinder liner increased the noise to a higher level than that generated with a flat piston crown. This was due to resonance between the four volumes. Using eight volumes instead decreased the noise. The noise...

  19. Quantum Noise Reduction with Pulsed Light in Optical Fibers.

    Science.gov (United States)

    Bergman, Keren

    Optical fibers offer considerable advantages over bulk nonlinear media for the generation of squeezed states. This thesis reports on experimental investigations of reducing quantum noise by means of squeezing in nonlinear fiber optic interferometers. Fibers have low insertion loss which allows for long interaction lengths. High field intensities are easily achieved in the small cores of single mode fibers. Additionally, the nonlinear process employed is self phase modulation or the Kerr effect, whose broad band nature requires no phase matching and can be exploited with ultra-short pulses of high peak intensity. All these advantageous features of fibers result in easily obtained large nonlinear phase shifts and subsequently large squeezing parameters. By the self phase modulation process a correlation is produced between the phase and amplitude fluctuations of the optical field. The attenuated or squeezed quadrature has a lower noise level than the initial level associated with the coherent state field before propagation. The resulting reduced quantum noise quadrature can be utilized to improve the sensitivity of a phase measuring instrument such as an interferometer. Because the Kerr nonlinearity is a degenerate self pumping process, the squeezed noise is at the same frequency as the pump field. Classical pump noise can therefore interfere with the desired measurement of the quantum noise reduction. The most severe noise process is the phase noise caused by thermally induced index modulation of the fiber. This noise termed Guided Acoustic Wave Brillouin Scattering, or GAWBS, by previous researchers is studied and analyzed. Experiments performed to overcome GAWBS successfully with several schemes are described. An experimental demonstration of an interferometric measurement with better sensitivity than the standard quantum limit is described. The results lead to new understandings into the limitations of quantum noise reduction that can be achieved in the

  20. Traffic background level and signal duration effects on aircraft noise judgment

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, G W; Haasz, A A

    1977-04-22

    The effects of background traffic noise level and signal duration on perceived aircraft noise levels during a flyover event are investigated. Tapes of traffic noise at different levels on which aircraft flyover noise events of different durations were superimposed were played to groups of observers in a room simulating indoor conditions. It is found that the presence of steady background traffic noise reduces the perceived noisiness of aircraft flyovers provided that the duration of the flyover event is sufficiently short in relation to flyover time. For a given event level, a reduction of 21 dB(A) in background noise level leads to the perception of a 5.5 dB(A) increase in peak event level. Regressions of observer response with the noise pollution index show a lower correlation than those with variables based on background noise level and peak signal level, although the data are found to exhibit a number of significant trends associated with noise pollution index variations.

  1. A Background Noise Reduction Technique Using Adaptive Noise Cancellation for Microphone Arrays

    Science.gov (United States)

    Spalt, Taylor B.; Fuller, Christopher R.; Brooks, Thomas F.; Humphreys, William M., Jr.; Brooks, Thomas F.

    2011-01-01

    Background noise in wind tunnel environments poses a challenge to acoustic measurements due to possible low or negative Signal to Noise Ratios (SNRs) present in the testing environment. This paper overviews the application of time domain Adaptive Noise Cancellation (ANC) to microphone array signals with an intended application of background noise reduction in wind tunnels. An experiment was conducted to simulate background noise from a wind tunnel circuit measured by an out-of-flow microphone array in the tunnel test section. A reference microphone was used to acquire a background noise signal which interfered with the desired primary noise source signal at the array. The technique s efficacy was investigated using frequency spectra from the array microphones, array beamforming of the point source region, and subsequent deconvolution using the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) algorithm. Comparisons were made with the conventional techniques for improving SNR of spectral and Cross-Spectral Matrix subtraction. The method was seen to recover the primary signal level in SNRs as low as -29 dB and outperform the conventional methods. A second processing approach using the center array microphone as the noise reference was investigated for more general applicability of the ANC technique. It outperformed the conventional methods at the -29 dB SNR but yielded less accurate results when coherence over the array dropped. This approach could possibly improve conventional testing methodology but must be investigated further under more realistic testing conditions.

  2. Adaptive mean filtering for noise reduction in CT polymer gel dosimetry

    International Nuclear Information System (INIS)

    Hilts, Michelle; Jirasek, Andrew

    2008-01-01

    X-ray computed tomography (CT) as a method of extracting 3D dose information from irradiated polymer gel dosimeters is showing potential as a practical means to implement gel dosimetry in a radiation therapy clinic. However, the response of CT contrast to dose is weak and noise reduction is critical in order to achieve adequate dose resolutions with this method. Phantom design and CT imaging technique have both been shown to decrease image noise. In addition, image postprocessing using noise reduction filtering techniques have been proposed. This work evaluates in detail the use of the adaptive mean filter for reducing noise in CT gel dosimetry. Filter performance is systematically tested using both synthetic patterns mimicking a range of clinical dose distribution features as well as actual clinical dose distributions. Both low and high signal-to-noise ratio (SNR) situations are examined. For all cases, the effects of filter kernel size and the number of iterations are investigated. Results indicate that adaptive mean filtering is a highly effective tool for noise reduction CT gel dosimetry. The optimum filtering strategy depends on characteristics of the dose distributions and image noise level. For low noise images (SNR ∼20), the filtered results are excellent and use of adaptive mean filtering is recommended as a standard processing tool. For high noise images (SNR ∼5) adaptive mean filtering can also produce excellent results, but filtering must be approached with more caution as spatial and dose distortions of the original dose distribution can occur

  3. Noise reduction in long‐period seismograms by way of array summing

    Science.gov (United States)

    Ringler, Adam; Wilson, David; Storm, Tyler; Marshall, Benjamin T.; Hutt, Charles R.; Holland, Austin

    2016-01-01

    Long‐period (>100  s period) seismic data can often be dominated by instrumental noise as well as local site noise. When multiple collocated sensors are installed at a single site, it is possible to improve the overall station noise levels by applying stacking methods to their traces. We look at the noise reduction in long‐period seismic data by applying the time–frequency phase‐weighted stacking method of Schimmel and Gallart (2007) as well as the phase‐weighted stacking (PWS) method of Schimmel and Paulssen (1997) to four collocated broadband sensors installed in the quiet Albuquerque Seismological Laboratory underground vault. We show that such stacking methods can improve vertical noise levels by as much as 10 dB over the mean background noise levels at 400 s period, suggesting that greater improvements could be achieved with an array involving multiple sensors. We also apply this method to reduce local incoherent noise on horizontal seismic records of the 2 March 2016 Mw 7.8 Sumatra earthquake, where the incoherent noise levels at very long periods are similar in amplitude to the earthquake signal. To maximize the coherency, we apply the PWS method to horizontal data where relative azimuths between collocated sensors are estimated and compared with a simpler linear stack with no azimuthal rotation. Such methods could help reduce noise levels at various seismic stations where multiple high‐quality sensors have been deployed. Such small arrays may also provide a solution to improving long‐period noise levels at Global Seismographic Network stations.

  4. Detection threshold for sound distortion resulting from noise reduction in normal-hearing and hearing-impaired listeners.

    Science.gov (United States)

    Brons, Inge; Dreschler, Wouter A; Houben, Rolph

    2014-09-01

    Hearing-aid noise reduction should reduce background noise, but not disturb the target speech. This objective is difficult because noise reduction suffers from a trade-off between the amount of noise removed and signal distortion. It is unknown if this important trade-off differs between normal-hearing (NH) and hearing-impaired (HI) listeners. This study separated the negative effect of noise reduction (distortion) from the positive effect (reduction of noise) to allow the measurement of the detection threshold for noise-reduction (NR) distortion. Twelve NH subjects and 12 subjects with mild to moderate sensorineural hearing loss participated in this study. The detection thresholds for distortion were determined using an adaptive procedure with a three-interval, two-alternative forced-choice paradigm. Different levels of distortion were obtained by changing the maximum amount of noise reduction. Participants were also asked to indicate their preferred NR strength. The detection threshold for overall distortion was higher for HI subjects than for NH subjects, suggesting that stronger noise reduction can be applied for HI listeners without affecting the perceived sound quality. However, the preferred NR strength of HI listeners was closer to their individual detection threshold for distortion than in NH listeners. This implies that HI listeners tolerate fewer audible distortions than NH listeners.

  5. Application of system concept in vibration and noise reduction

    Directory of Open Access Journals (Sweden)

    SHENG Meiping

    2017-08-01

    Full Text Available Although certain vibration and noise control technologies are maturing, such as vibration absorption, vibration isolation, sound absorption and sound insulation, and new methods for specific frequency bands or special environments have been proposed unceasingly, there is still no guarantee that practical effective vibration and noise reduction can be obtained. An important constraint for vibration and noise reduction is the lack of a system concept, and the integrity and relevance of such practical systems as ship structure have not obtained enough attention. We have tried to use the system engineering theory in guiding vibration and noise reduction, and have already achieved certain effects. Based on the system concept, the noise control of a petroleum pipeline production workshop has been completed satisfactorily, and the abnormal noise source identification of an airplane has been accomplished successfully. We want to share our experience and suggestions to promote the popularization of the system engineering theory in vibration and noise control.

  6. Utilisation of polyurethane composit with 50% composition of roystonea regia fiber as noise reduction panel on car hood

    Science.gov (United States)

    Ikhwansyah; Mulia; Gunawan, S.; Lubis, R. D. W.

    2018-02-01

    The objective is to get the characteristics of noise reduction, noise reduction level, variety of measurement spaces, and knowing the process in making acoustic material of natural fiber becomes noise reduction on a car hood. The process of making noise reduction material used casting method and pressed by using molded press. The composition of noise reduction material consist of 50% roystonea regia by 32 mesh and 50% combined by gypsum and polyurethane. The result shows that the average result of noise reduction at X1- side is 5,7% and X2- side is 3,9%, X1+ side is 0,9% and X2+ side is 6,2%, Z1- side is 8,9% and Z2- side is 10,1%, Z1+ side is 9,7% and Z2+ side is 10,01%. The main conclusion of the study shows that a noise reduction which made of roystonea regia with 32 mesh mixed by matrix of polyurethane and gypsum is appropriate for noise reduction on car hood.

  7. Simulated dose reduction by adding artificial noise to measured raw data: A validation study

    International Nuclear Information System (INIS)

    Soederberg, M.; Gunnarsson, M.; Nilsson, M.

    2010-01-01

    The purpose of this study was to verify and validate a noise simulation tool called Dose Tutor (VAMP GmbH) in terms of level and texture of the simulated noise. By adding artificial noise to measured computed tomography (CT) raw data, a scan acquired with a lower dose (mAs) than the actual one can be simulated. A homogeneous polyethylene phantom and an anthropomorphic chest phantom were scanned for different mAs levels, tube voltages, slice thicknesses and reconstruction kernels. The simulated noise levels were compared with the noise levels in real transverse slice images actually acquired with corresponding mAs values. In general, the noise comparisons showed acceptable agreement in magnitude (<20% deviation in pixel standard deviation). Also, the calculated noise power spectra were similar, which indicates that the noise texture is correctly reproduced. In conclusion, this study establishes that the Dose Tutor might be a useful tool for estimating the dose reduction potential for CT protocols. (authors)

  8. Analysis of Individual Preferences for Tuning Noise-Reduction Algorithms

    NARCIS (Netherlands)

    Houben, Rolph; Dijkstra, Tjeerd M. H.; Dreschler, Wouter A.

    2012-01-01

    There is little research on user preference for different settings of noise reduction, especially for individual users. We therefore measured individual preferences for pairs of audio streams differing in the trade-off between noise reduction and speech distortion. A logistic probability model was

  9. The effectiveness of environmental strategies on noise reduction in a pediatric intensive care unit: creation of single-patient bedrooms and reducing noise sources.

    Science.gov (United States)

    Kol, Emine; Aydın, Perihan; Dursun, Oguz

    2015-07-01

    Noise is a substantial problem for both patients and healthcare workers in hospitals. This study aimed to determine the effectiveness of environmental strategies (creating single-patient rooms and reducing noise sources) in noise reduction in a pediatric intensive care unit. Noise measurement in the unit was conducted in two phases. In the first phase, measurements aimed at determining the unit's present level of noise were performed over 4 weeks in December 2013. During the month following the first measurement phase, the intensive care unit (ICU) was moved to a new location and noise-reducing strategies were implemented. The second phase, in May 2014, measured noise levels in the newly constructed environment. The noise levels before and after environmental changes were statistically significant at 72.6 dB-A and 56 dB-A, respectively (p noise-reducing strategies can be effective in controlling environmental noise in the ICU. © 2015, Wiley Periodicals, Inc.

  10. Spatial-temporal noise reduction method optimized for real-time implementation

    Science.gov (United States)

    Romanenko, I. V.; Edirisinghe, E. A.; Larkin, D.

    2013-02-01

    Image de-noising in the spatial-temporal domain has been a problem studied in-depth in the field of digital image processing. However complexity of algorithms often leads to high hardware resource usage, or computational complexity and memory bandwidth issues, making their practical use impossible. In our research we attempt to solve these issues with an optimized implementation of a practical spatial-temporal de-noising algorithm. Spatial-temporal filtering was performed in Bayer RAW data space, which allowed us to benefit from predictable sensor noise characteristics and reduce memory bandwidth requirements. The proposed algorithm efficiently removes different kinds of noise in a wide range of signal to noise ratios. In our algorithm the local motion compensation is performed in Bayer RAW data space, while preserving the resolution and effectively improving the signal to noise ratios of moving objects. The main challenge for the use of spatial-temporal noise reduction algorithms in video applications is the compromise between the quality of the motion prediction and the complexity of the algorithm and required memory bandwidth. In photo and video applications it is very important that moving objects should stay sharp, while the noise is efficiently removed in both the static background and moving objects. Another important use case is the case when background is also non-static as well as the foreground where objects are also moving. Taking into account the achievable improvement in PSNR (on the level of the best known noise reduction techniques, like VBM3D) and low algorithmic complexity, enabling its practical use in commercial video applications, the results of our research can be very valuable.

  11. Propulsion Noise Reduction Research in the NASA Advanced Air Transport Technology Project

    Science.gov (United States)

    Van Zante, Dale; Nark, Douglas; Fernandez, Hamilton

    2017-01-01

    The Aircraft Noise Reduction (ANR) sub-project is focused on the generation, development, and testing of component noise reduction technologies progressing toward the NASA far term noise goals while providing associated near and mid-term benefits. The ANR sub-project has efforts in airframe noise reduction, propulsion (including fan and core) noise reduction, acoustic liner technology, and propulsion airframe aeroacoustics for candidate conventional and unconventional aircraft configurations. The current suite of propulsion specific noise research areas is reviewed along with emerging facility and measurement capabilities. In the longer term, the changes in engine and aircraft configuration will influence the suite of technologies necessary to reduce noise in next generation systems.

  12. Noise reduction with complex bilateral filter.

    Science.gov (United States)

    Matsumoto, Mitsuharu

    2017-12-01

    This study introduces a noise reduction technique that uses a complex bilateral filter. A bilateral filter is a nonlinear filter originally developed for images that can reduce noise while preserving edge information. It is an attractive filter and has been used in many applications in image processing. When it is applied to an acoustical signal, small-amplitude noise is reduced while the speech signal is preserved. However, a bilateral filter cannot handle noise with relatively large amplitudes owing to its innate characteristics. In this study, the noisy signal is transformed into the time-frequency domain and the filter is improved to handle complex spectra. The high-amplitude noise is reduced in the time-frequency domain via the proposed filter. The features and the potential of the proposed filter are also confirmed through experiments.

  13. Advanced digital signal processing and noise reduction

    CERN Document Server

    Vaseghi, Saeed V

    2008-01-01

    Digital signal processing plays a central role in the development of modern communication and information processing systems. The theory and application of signal processing is concerned with the identification, modelling and utilisation of patterns and structures in a signal process. The observation signals are often distorted, incomplete and noisy and therefore noise reduction, the removal of channel distortion, and replacement of lost samples are important parts of a signal processing system. The fourth edition of Advanced Digital Signal Processing and Noise Reduction updates an

  14. Wind Noise Reduction in a Non-Porous Subsurface Windscreen

    Science.gov (United States)

    Zuckerwar, Allan J.; Shams, Qamar A.; Knight, H. Keith

    2012-01-01

    Measurements of wind noise reduction were conducted on a box-shaped, subsurface windscreen made of closed cell polyurethane foam. The windscreen was installed in the ground with the lid flush with the ground surface. The wind was generated by means of a fan, situated on the ground, and the wind speed was measured at the center of the windscreen lid with an ultrasonic anemometer. The wind speed was controlled by moving the fan to selected distances from the windscreen. The wind noise was measured on a PCB Piezotronics 3†electret microphone. Wind noise spectra were measured with the microphone exposed directly to the wind (atop the windscreen lid) and with the microphone installed inside the windscreen. The difference between the two spectra comprises the wind noise reduction. At wind speeds of 3, 5, and 7 m/s, the wind noise reduction is typically 15 dB over the frequency range of 0.1-20 Hz.

  15. Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

    Science.gov (United States)

    Ott, Martin; Blaimer, Martin; Breuer, Felix; Grodzki, David; Heismann, Björn; Jakob, Peter

    2016-02-01

    To reduce acoustic noise levels in T 1-weighted and proton-density-weighted turbo spin-echo (TSE) sequences, which typically reach acoustic noise levels up to 100 dB(A) in clinical practice. Five acoustic noise reduction strategies were combined: (1) gradient ramps and shapes were changed from trapezoidal to triangular, (2) variable-encoding-time imaging was implemented to relax the phase-encoding gradient timing, (3) RF pulses were adapted to avoid the need for reversing the polarity of the slice-rewinding gradient, (4) readout bandwidth was increased to provide more time for gradient activity on other axes, (5) the number of slices per TR was reduced to limit the total gradient activity per unit time. We evaluated the influence of each measure on the acoustic noise level, and conducted in vivo measurements on a healthy volunteer. Sound recordings were taken for comparison. An overall acoustic noise reduction of up to 16.8 dB(A) was obtained by the proposed strategies (1-4) and the acquisition of half the number of slices per TR only. Image quality in terms of SNR and CNR was found to be preserved. The proposed measures in this study allowed a threefold reduction in the acoustic perception of T 1-weighted and proton-density-weighted TSE sequences compared to a standard TSE-acquisition. This could be achieved without visible degradation of image quality, showing the potential to improve patient comfort and scan acceptability.

  16. Filtering out the noise: evaluating the impact of noise and sound reduction strategies on sleep quality for ICU patients.

    Science.gov (United States)

    Bosma, Karen J; Ranieri, V Marco

    2009-01-01

    The review article by Xie and colleagues examines the impact of noise and noise reduction strategies on sleep quality for critically ill patients. Evaluating the impact of noise on sleep quality is challenging, as it must be measured relative to other factors that may be more or less disruptive to patients' sleep. Such factors may be difficult for patients, observers, and polysomnogram interpreters to identify, due to our limited understanding of the causes of sleep disruption in the critically ill, as well as the challenges in recording and quantifying sleep stages and sleep fragmentation in the intensive care unit. Furthermore, most research in this field has focused on noise level, whereas acousticians typically evaluate additional parameters such as noise spectrum and reverberation time. The authors highlight the disparate results and limitations of existing studies, including the lack of attention to other acoustic parameters besides sound level, and the combined effects of different sleep disturbing factors.

  17. Binaural noise reduction via cue-preserving MMSE filter and adaptive-blocking-based noise PSD estimation

    Science.gov (United States)

    Azarpour, Masoumeh; Enzner, Gerald

    2017-12-01

    Binaural noise reduction, with applications for instance in hearing aids, has been a very significant challenge. This task relates to the optimal utilization of the available microphone signals for the estimation of the ambient noise characteristics and for the optimal filtering algorithm to separate the desired speech from the noise. The additional requirements of low computational complexity and low latency further complicate the design. A particular challenge results from the desired reconstruction of binaural speech input with spatial cue preservation. The latter essentially diminishes the utility of multiple-input/single-output filter-and-sum techniques such as beamforming. In this paper, we propose a comprehensive and effective signal processing configuration with which most of the aforementioned criteria can be met suitably. This relates especially to the requirement of efficient online adaptive processing for noise estimation and optimal filtering while preserving the binaural cues. Regarding noise estimation, we consider three different architectures: interaural (ITF), cross-relation (CR), and principal-component (PCA) target blocking. An objective comparison with two other noise PSD estimation algorithms demonstrates the superiority of the blocking-based noise estimators, especially the CR-based and ITF-based blocking architectures. Moreover, we present a new noise reduction filter based on minimum mean-square error (MMSE), which belongs to the class of common gain filters, hence being rigorous in terms of spatial cue preservation but also efficient and competitive for the acoustic noise reduction task. A formal real-time subjective listening test procedure is also developed in this paper. The proposed listening test enables a real-time assessment of the proposed computationally efficient noise reduction algorithms in a realistic acoustic environment, e.g., considering time-varying room impulse responses and the Lombard effect. The listening test outcome

  18. Noise Reduction of Measurement Data using Linear Digital Filters

    Directory of Open Access Journals (Sweden)

    Hitzmann B.

    2007-12-01

    Full Text Available In this paper Butterworth, Chebyshev (Type I and II and Elliptic digital filters are designed for signal noise reduction. On-line data measurements of substrate concentration from E. coli fed-batch cultivation process are used. Application of the designed filters leads to a successful noise reduction of on-line glucose measurements. The digital filters presented here are simple, easy to implement and effective - the used filters allow for a smart compromise between signal information and noise corruption.

  19. Image noise reduction algorithm for digital subtraction angiography: clinical results.

    Science.gov (United States)

    Söderman, Michael; Holmin, Staffan; Andersson, Tommy; Palmgren, Charlotta; Babic, Draženko; Hoornaert, Bart

    2013-11-01

    To test the hypothesis that an image noise reduction algorithm designed for digital subtraction angiography (DSA) in interventional neuroradiology enables a reduction in the patient entrance dose by a factor of 4 while maintaining image quality. This clinical prospective study was approved by the local ethics committee, and all 20 adult patients provided informed consent. DSA was performed with the default reference DSA program, a quarter-dose DSA program with modified acquisition parameters (to reduce patient radiation dose exposure), and a real-time noise-reduction algorithm. Two consecutive biplane DSA data sets were acquired in each patient. The dose-area product (DAP) was calculated for each image and compared. A randomized, blinded, offline reading study was conducted to show noninferiority of the quarter-dose image sets. Overall, 40 samples per treatment group were necessary to acquire 80% power, which was calculated by using a one-sided α level of 2.5%. The mean DAP with the quarter-dose program was 25.3% ± 0.8 of that with the reference program. The median overall image quality scores with the reference program were 9, 13, and 12 for readers 1, 2, and 3, respectively. These scores increased slightly to 12, 15, and 12, respectively, with the quarter-dose program imaging chain. In DSA, a change in technique factors combined with a real-time noise-reduction algorithm will reduce the patient entrance dose by 75%, without a loss of image quality. RSNA, 2013

  20. Wind Noise Reduction using Non-negative Sparse Coding

    DEFF Research Database (Denmark)

    Schmidt, Mikkel N.; Larsen, Jan; Hsiao, Fu-Tien

    2007-01-01

    We introduce a new speaker independent method for reducing wind noise in single-channel recordings of noisy speech. The method is based on non-negative sparse coding and relies on a wind noise dictionary which is estimated from an isolated noise recording. We estimate the parameters of the model ...... and discuss their sensitivity. We then compare the algorithm with the classical spectral subtraction method and the Qualcomm-ICSI-OGI noise reduction method. We optimize the sound quality in terms of signal-to-noise ratio and provide results on a noisy speech recognition task....

  1. An Exceptional Purity of Sound: Noise Reduction Technology and the Inevitable Noise of Sound Recording

    NARCIS (Netherlands)

    Kromhout, M.

    2014-01-01

    The phenomenon of noise has resisted many attempts at framing it within a singular conceptual framework. Critically questioning the tendency to do so, this article asserts the complexities of different noise-phenomena by analysing a specific technology: technological noise reduction systems. Whereas

  2. The Effect of Age and Type of Noise on Speech Perception under Conditions of Changing Context and Noise Levels.

    Science.gov (United States)

    Taitelbaum-Swead, Riki; Fostick, Leah

    2016-01-01

    Everyday life includes fluctuating noise levels, resulting in continuously changing speech intelligibility. The study aims were: (1) to quantify the amount of decrease in age-related speech perception, as a result of increasing noise level, and (2) to test the effect of age on context usage at the word level (smaller amount of contextual cues). A total of 24 young adults (age 20-30 years) and 20 older adults (age 60-75 years) were tested. Meaningful and nonsense one-syllable consonant-vowel-consonant words were presented with the background noise types of speech noise (SpN), babble noise (BN), and white noise (WN), with a signal-to-noise ratio (SNR) of 0 and -5 dB. Older adults had lower accuracy in SNR = 0, with WN being the most difficult condition for all participants. Measuring the change in speech perception when SNR decreased showed a reduction of 18.6-61.5% in intelligibility, with age effect only for BN. Both young and older adults used less phonemic context with WN, as compared to other conditions. Older adults are more affected by an increasing noise level of fluctuating informational noise as compared to steady-state noise. They also use less contextual cues when perceiving monosyllabic words. Further studies should take into consideration that when presenting the stimulus differently (change in noise level, less contextual cues), other perceptual and cognitive processes are involved. © 2016 S. Karger AG, Basel.

  3. Practical Ranges of Loudness Levels of Various Types of Environmental Noise, Including Traffic Noise, Aircraft Noise, and Industrial Noise

    Directory of Open Access Journals (Sweden)

    Sabine A. Janssen

    2011-05-01

    Full Text Available In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A‑weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.

  4. Generative Adversarial Networks for Noise Reduction in Low-Dose CT.

    Science.gov (United States)

    Wolterink, Jelmer M; Leiner, Tim; Viergever, Max A; Isgum, Ivana

    2017-12-01

    Noise is inherent to low-dose CT acquisition. We propose to train a convolutional neural network (CNN) jointly with an adversarial CNN to estimate routine-dose CT images from low-dose CT images and hence reduce noise. A generator CNN was trained to transform low-dose CT images into routine-dose CT images using voxelwise loss minimization. An adversarial discriminator CNN was simultaneously trained to distinguish the output of the generator from routine-dose CT images. The performance of this discriminator was used as an adversarial loss for the generator. Experiments were performed using CT images of an anthropomorphic phantom containing calcium inserts, as well as patient non-contrast-enhanced cardiac CT images. The phantom and patients were scanned at 20% and 100% routine clinical dose. Three training strategies were compared: the first used only voxelwise loss, the second combined voxelwise loss and adversarial loss, and the third used only adversarial loss. The results showed that training with only voxelwise loss resulted in the highest peak signal-to-noise ratio with respect to reference routine-dose images. However, CNNs trained with adversarial loss captured image statistics of routine-dose images better. Noise reduction improved quantification of low-density calcified inserts in phantom CT images and allowed coronary calcium scoring in low-dose patient CT images with high noise levels. Testing took less than 10 s per CT volume. CNN-based low-dose CT noise reduction in the image domain is feasible. Training with an adversarial network improves the CNNs ability to generate images with an appearance similar to that of reference routine-dose CT images.

  5. Effects of venting on wind noise levels measured at the eardrum.

    Science.gov (United States)

    Chung, King

    2013-01-01

    Wind noise can be a nuisance to hearing aid users. With the advent of sophisticated feedback reduction algorithms, people with higher degrees of hearing loss are fit with larger vents than previously allowed, and more people with lesser degrees of hearing loss are fit with open hearing aids. The purpose of this study was to examine the effects of venting on wind noise levels in the ear canal for hearing aids with omnidirectional and directional microphones. Two behind-the-ear hearing aids were programmed when they were worn on a Knowles Electronics Manikin for Acoustic Research. The hearing aid worn on the right ear was programmed to the omnidirectional microphone mode and the one on the left to the directional microphone mode. The hearing aids were adjusted to linear amplification with flat frequency response in an anechoic chamber. Gains below 10 dB were used to avoid output limiting of wind noise levels at low input levels. Wind noise samples were recorded at the eardrum location in a wind tunnel at wind velocities ranging from a gentle to a strong breeze. The hearing aids were coupled to #13 tubings (i.e., open vent), or conventional skeleton earmolds with no vent, pressure vents, or 3mm vents. Polar and spectral characteristics of wind noise were analyzed off-line using MatLab programs. Wind noise levels in the ear canals were mostly predicted by vent-induced frequency response changes in the conventional earmold conditions for both omnidirectional and directional hearing aids. The open vent condition, however, yielded the lowest levels, which could not be entirely predicted by the frequency response changes of the hearing aids. This indicated that a wind-related vent effect permitted an additional amount of sound reduction in the ear canal, which could not be explained by known vent effects. For the microphone location, form factor, and gain settings tested, open fit hearing aids yielded lower noise levels at the eardrum location than conventional behind

  6. Anthropogenic noise alters bat activity levels and echolocation calls

    Directory of Open Access Journals (Sweden)

    Jessie P. Bunkley

    2015-01-01

    Full Text Available Negative impacts from anthropogenic noise are well documented for many wildlife taxa. Investigations of the effects of noise on bats however, have not been conducted outside of the laboratory. Bats that hunt arthropods rely on auditory information to forage. Part of this acoustic information can fall within the spectrum of anthropogenic noise, which can potentially interfere with signal reception and processing. Compressor stations associated with natural gas extraction produce broadband noise 24 hours a day, 365 days a year. With over half a million producing gas wells in the U.S. this infrastructure is a major source of noise pollution across the landscape. We conducted a ‘natural experiment’ in the second largest gas extraction field in the U.S. to investigate the potential effects of gas compressor station noise on the activity levels of the local bat assemblage. We used acoustic monitoring to compare the activity level (number of minutes in a night with a bat call of the bat assemblage at sites with compressor stations to sites lacking this infrastructure. We found that activity levels for the Brazilian free-tailed bat (Tadarida brasiliensis were 40% lower at loud compressor sites compared to quieter well pads, whereas the activity levels of four other species (Myotis californicus, M. cillolabrum, M. lucifugus, Parastrellus hesperus were not affected by noise. Furthermore, our results reveal that the assemblage of bat species emitting low frequency (35 kHz echolocation did not exhibit altered activity levels in noise. Lower activity levels of Brazilian free-tailed bats at loud sites indicate a potential reduction in habitat for this species. Additionally, a comparison of echolocation search calls produced by free-tailed bats at sites with and without compressor stations reveal that this species modifies its echolocation search calls in noise—producing longer calls with a narrower bandwidth. Call alterations might affect prey

  7. Reduction of 1/f noise in graphene after electron-beam irradiation

    International Nuclear Information System (INIS)

    Zahid Hossain, Md.; Rumyantsev, Sergey; Shur, Michael S.; Balandin, Alexander A.

    2013-01-01

    We investigated experimentally the effect of the electron-beam irradiation on the level of the low-frequency 1/f noise in graphene devices. It was found that 1/f noise in graphene reduces with increasing concentration of defects induced by irradiation. The increased amount of structural disorder in graphene under irradiation was verified with micro-Raman spectroscopy. The bombardment of graphene devices with 20-keV electrons reduced the noise spectral density, S I /I 2 (I is the source-drain current) by an order-of magnitude at the radiation dose of 10 4 μC/cm 2 . We analyzed the observed noise reduction in the limiting cases of the mobility and carrier number fluctuation mechanisms. The obtained results are important for the proposed graphene applications in analog, mixed-signal, and radio-frequency systems, integrated circuits and sensors.

  8. HF DBD plasma actuators for reduction of cylinder noise in flow

    Science.gov (United States)

    Kopiev, V. F.; Kazansky, P. N.; Kopiev, V. A.; Moralev, I. A.; Zaytsev, M. Yu

    2017-11-01

    Surface high frequency dielectric barrier discharge (HF DBD) was used to reduce flow-induced noise, radiated by circular cylinder in cross flow. Effect of HF DBD actuators is studied for flow velocity up to 80 m s-1 (Reynolds numbers up to 2.18 · 105), corresponding to the typical aircraft landing approach speed. Noise measurements were performed by microphone array in anechoic chamber; averaged flow parameters were studied by particle image velocimetry (PIV). Actuator was powered by high-frequency voltage in hundreds kHz range in steady or modulated mode with the modulation frequency of 0.3-20 kHz (Strouhal number St of 0.4 to 20). It is demonstrated that upstream directed plasma actuators are able to reduce the vortex noise of a cylinder by 10 dB. Noise reduction is accompanied by significant reorganization of the wake behind a cylinder, decreasing both wake width and turbulence level. The physical mechanism related to broadband noise control by HF DBD actuator is also discussed.

  9. Noise Exposure of Teachers in Nursery Schools-Evaluation of Measures for Noise Reduction When Dropping DUPLO Toy Bricks into Storage Cases by Sound Analyses.

    Science.gov (United States)

    Gebauer, Konstanze; Scharf, Thomas; Baumann, Uwe; Groneberg, David A; Bundschuh, Matthias

    2016-07-04

    Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. The lowest LAFmax was measured in cases consisting of "metal grid" (90.71 dB) or of a woven willow "basket" (91.61 dB), whereas a case of "aluminium" (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs "metal grid" and "basket". The insertion of PU-foam achieved the most significant attenuation of LAFmax (-13.88 dB) and, in the frequency analyses, the best sound damping. The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven "basket" with an insert of PU-foam.

  10. Background noise levels in Europe

    OpenAIRE

    Gjestland, Truls

    2008-01-01

    - This report gives a brief overview of typical background noise levels in Europe, and suggests a procedure for the prediction of background noise levels based on population density. A proposal for the production of background noise maps for Europe is included.

  11. Acceptable noise level

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Nielsen, Lars Holme; Lantz, Johannes

    2012-01-01

    The acceptable noise level (ANL) is used to quantify the amount of background noise that subjects can accept while listening to speech, and is suggested for prediction of individual hearing-aid use. The aim of this study was to assess the repeatability of the ANL measured in normal-hearing subjects...... using running Danish and non-semantic speech materials as stimuli and modulated speech-spectrum and multi-talker babble noises as competing stimuli....

  12. Acceptable noise level

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Nielsen, Lars Holme; Lantz, Johannes

    2012-01-01

    The acceptable noise level (ANL) is used to quantify the amount of background noise that subjects can accept while listening to speech, and is suggested for prediction of individual hearing-aid use. The aim of this study was to assess the repeatability of the ANL measured in normal-hearing subjec...... using running Danish and non-semantic speech materials as stimuli and modulated speech-spectrum and multi-talker babble noises as competing stimuli....

  13. Blade-Mounted Flap Control for BVI Noise Reduction Proof-of-Concept Test

    Science.gov (United States)

    Dawson, Seth; Hassan, Ahmed; Straub, Friedrich; Tadghighi, Hormoz

    1995-01-01

    This report describes a wind tunnel test of the McDonnell Douglas Helicopter Systems (MDHS) Active Flap Model Rotor at the NASA Langley 14- by 22-Foot Subsonic Tunnel. The test demonstrated that BVI noise reductions and vibration reductions were possible with the use of an active flap. Aerodynamic results supported the acoustic data trends, showing a reduction in the strength of the tip vortex with the deflection of the flap. Acoustic results showed that the flap deployment, depending on the peak deflection angle and azimuthal shift in its deployment schedule, can produce BVI noise reductions as much as 6 dB on the advancing and retreating sides. The noise reduction was accompanied by an increase in low frequency harmonic noise and high frequency broadband noise. A brief assessment of the effect of the flap on vibration showed that significant reductions were possible. The greatest vibration reductions (as much as 76%) were found in the four per rev pitching moment at the hub. Performance improvement cam results were inconclusive, as the improvements were predicted to be smaller than the resolution of the rotor balance.

  14. Training Methods for Image Noise Level Estimation on Wavelet Components

    Directory of Open Access Journals (Sweden)

    A. De Stefano

    2004-12-01

    Full Text Available The estimation of the standard deviation of noise contaminating an image is a fundamental step in wavelet-based noise reduction techniques. The method widely used is based on the mean absolute deviation (MAD. This model-based method assumes specific characteristics of the noise-contaminated image component. Three novel and alternative methods for estimating the noise standard deviation are proposed in this work and compared with the MAD method. Two of these methods rely on a preliminary training stage in order to extract parameters which are then used in the application stage. The sets used for training and testing, 13 and 5 images, respectively, are fully disjoint. The third method assumes specific statistical distributions for image and noise components. Results showed the prevalence of the training-based methods for the images and the range of noise levels considered.

  15. Adaptive noise reduction circuit for a sound reproduction system

    Science.gov (United States)

    Engebretson, A. Maynard (Inventor); O'Connell, Michael P. (Inventor)

    1995-01-01

    A noise reduction circuit for a hearing aid having an adaptive filter for producing a signal which estimates the noise components present in an input signal. The circuit includes a second filter for receiving the noise-estimating signal and modifying it as a function of a user's preference or as a function of an expected noise environment. The circuit also includes a gain control for adjusting the magnitude of the modified noise-estimating signal, thereby allowing for the adjustment of the magnitude of the circuit response. The circuit also includes a signal combiner for combining the input signal with the adjusted noise-estimating signal to produce a noise reduced output signal.

  16. Passive Techniques for Fan Noise Reduction in New Turbofan Engines: Review

    Directory of Open Access Journals (Sweden)

    M.Gorj-Bandpy

    2013-03-01

    Full Text Available Among the various environmental concerns, the aircraft noise item has been constantly growing in importance over the past years. Measures for its reduction at the source as well its mitigation around airports must take into account aspects of medicine and technical design as well as legal and land use planning aspects. Fan noise is one of the principal noise sources in turbofan aero-engines. In this paper a review of the main technologies employed for the reduction of fan noise turbofan engines is presented.

  17. Noise reduction by wavelet thresholding

    National Research Council Canada - National Science Library

    Jansen, Maarten

    2001-01-01

    .... I rather present new material and own insights in the que stions involved with wavelet based noise reduction . On the other hand , the presented material does cover a whole range of methodologies, and in that sense, the book may serve as an introduction into the domain of wavelet smoothing. Throughout the text, three main properties show up ever again: spar...

  18. Noise levels in Damascus city

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Maslmani, Y.

    2004-01-01

    Outdoor noise levels were measured at 22 sites in Damascus city. Sound level meter model NC-10 with a 20-140 dBA selectable range was used in the current investigation. At each site noise data were collected from 7 to 21 o'clock. The results showed that the noise levels were higher than WHO (World Health Organization) standard by 5-24.7 dB, 10-16 dB, 10-11 dB and 12-17 dB in residential, commercial, Commercial-industrial, and Heavy traffic streets respectively. Indoor and outdoor noise levels in some hospitals were higher than WHO standard by 15-28 dB and 19-23 dB respectively. The study showed that the authorities administration must take necessary procedures to reduce the noise levels in residential regions and in the regions surrounding the hospitals. (author)

  19. Engine-propeller power plant aircraft community noise reduction key methods

    Science.gov (United States)

    Moshkov P., A.; Samokhin V., F.; Yakovlev A., A.

    2018-04-01

    Basic methods of aircraft-type flying vehicle engine-propeller power plant noise reduction were considered including single different-structure-and-arrangement propellers and piston engines. On the basis of a semiempirical model the expressions for blade diameter and number effect evaluation upon propeller noise tone components under thrust constancy condition were proposed. Acoustic tests performed at Moscow Aviation institute airfield on the whole qualitatively proved the obtained ratios. As an example of noise and detectability reduction provision a design-and-experimental estimation of propeller diameter effect upon unmanned aircraft audibility boundaries was performed. Future investigation ways were stated to solve a low-noise power plant design problem for light aircraft and unmanned aerial vehicles.

  20. Noise reduction in optically controlled quantum memory

    Science.gov (United States)

    Ma, Lijun; Slattery, Oliver; Tang, Xiao

    2018-05-01

    Quantum memory is an essential tool for quantum communications systems and quantum computers. An important category of quantum memory, called optically controlled quantum memory, uses a strong classical beam to control the storage and re-emission of a single-photon signal through an atomic ensemble. In this type of memory, the residual light from the strong classical control beam can cause severe noise and degrade the system performance significantly. Efficiently suppressing this noise is a requirement for the successful implementation of optically controlled quantum memories. In this paper, we briefly introduce the latest and most common approaches to quantum memory and review the various noise-reduction techniques used in implementing them.

  1. Perceptual effects of noise reduction by time-frequency masking of noisy speech.

    Science.gov (United States)

    Brons, Inge; Houben, Rolph; Dreschler, Wouter A

    2012-10-01

    Time-frequency masking is a method for noise reduction that is based on the time-frequency representation of a speech in noise signal. Depending on the estimated signal-to-noise ratio (SNR), each time-frequency unit is either attenuated or not. A special type of a time-frequency mask is the ideal binary mask (IBM), which has access to the real SNR (ideal). The IBM either retains or removes each time-frequency unit (binary mask). The IBM provides large improvements in speech intelligibility and is a valuable tool for investigating how different factors influence intelligibility. This study extends the standard outcome measure (speech intelligibility) with additional perceptual measures relevant for noise reduction: listening effort, noise annoyance, speech naturalness, and overall preference. Four types of time-frequency masking were evaluated: the original IBM, a tempered version of the IBM (called ITM) which applies limited and non-binary attenuation, and non-ideal masking (also tempered) with two different types of noise-estimation algorithms. The results from ideal masking imply that there is a trade-off between intelligibility and sound quality, which depends on the attenuation strength. Additionally, the results for non-ideal masking suggest that subjective measures can show effects of noise reduction even if noise reduction does not lead to differences in intelligibility.

  2. Noise Exposure of Teachers in Nursery Schools—Evaluation of Measures for Noise Reduction When Dropping DUPLO Toy Bricks into Storage Cases by Sound Analyses

    Directory of Open Access Journals (Sweden)

    Konstanze Gebauer

    2016-07-01

    Full Text Available Background: Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. Methods: This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam were investigated. Results: The lowest LAFmax was measured in cases consisting of “metal grid” (90.71 dB or of a woven willow “basket” (91.61 dB, whereas a case of “aluminium” (103.34 dB generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs “metal grid” and “basket”. The insertion of PU-foam achieved the most significant attenuation of LAFmax (−13.88 dB and, in the frequency analyses, the best sound damping. Conclusion: The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven “basket” with an insert of PU-foam.

  3. HF DBD plasma actuators for reduction of cylinder noise in flow

    International Nuclear Information System (INIS)

    Kopiev, V F; Kopiev, V A; Zaytsev, M Yu; Kazansky, P N; Moralev, I A

    2017-01-01

    Surface high frequency dielectric barrier discharge (HF DBD) was used to reduce flow-induced noise, radiated by circular cylinder in cross flow. Effect of HF DBD actuators is studied for flow velocity up to 80 m s −1 (Reynolds numbers up to 2.18 · 10 5 ), corresponding to the typical aircraft landing approach speed. Noise measurements were performed by microphone array in anechoic chamber; averaged flow parameters were studied by particle image velocimetry (PIV). Actuator was powered by high-frequency voltage in hundreds kHz range in steady or modulated mode with the modulation frequency of 0.3–20 kHz (Strouhal number St of 0.4 to 20). It is demonstrated that upstream directed plasma actuators are able to reduce the vortex noise of a cylinder by 10 dB. Noise reduction is accompanied by significant reorganization of the wake behind a cylinder, decreasing both wake width and turbulence level. The physical mechanism related to broadband noise control by HF DBD actuator is also discussed. (paper)

  4. Joint models for noise annoyance and willingness to pay for road noise reduction

    DEFF Research Database (Denmark)

    Fosgerau, Mogens; Bue Bjørner, Thomas

    2006-01-01

    Recent contingent valuation (CV) studies of the willingness to pay (WTP) for road noise reduction have used stated annoyance as an independent variable. We argue that this may be inappropriate due to potential endogeneity bias. Instead, an alternative model is proposed that treats both WTP...... and annoyance as endogenous variables in a simultaneous equation model as a combination of a linear regression with an ordered probit with correlated error terms and possibly common parameters. Thus, information on stated annoyance is utilised to estimate WTP with increased efficiency. Application of the model...... to a dataset from Copenhagen indicates a potential for improving the precision of the estimate of WTP for noise reduction with CV data....

  5. Evidence of "hidden hearing loss" following noise exposures that produce robust TTS and ABR wave-I amplitude reductions.

    Science.gov (United States)

    Lobarinas, Edward; Spankovich, Christopher; Le Prell, Colleen G

    2017-06-01

    In animals, noise exposures that produce robust temporary threshold shifts (TTS) can produce immediate damage to afferent synapses and long-term degeneration of low spontaneous rate auditory nerve fibers. This synaptopathic damage has been shown to correlate with reduced auditory brainstem response (ABR) wave-I amplitudes at suprathreshold levels. The perceptual consequences of this "synaptopathy" remain unknown but have been suggested to include compromised hearing performance in competing background noise. Here, we used a modified startle inhibition paradigm to evaluate whether noise exposures that produce robust TTS and ABR wave-I reduction but not permanent threshold shift (PTS) reduced hearing-in-noise performance. Animals exposed to 109 dB SPL octave band noise showed TTS >30 dB 24-h post noise and modest but persistent ABR wave-I reduction 2 weeks post noise despite full recovery of ABR thresholds. Hearing-in-noise performance was negatively affected by the noise exposure. However, the effect was observed only at the poorest signal to noise ratio and was frequency specific. Although TTS >30 dB 24-h post noise was a predictor of functional deficits, there was no relationship between the degree of ABR wave-I reduction and degree of functional impairment. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. A PIV Study of Slotted Air Injection for Jet Noise Reduction

    Science.gov (United States)

    Henderson, Brenda S.; Wernet, Mark P.

    2012-01-01

    Results from acoustic and Particle Image Velocimetry (PIV) measurements are presented for single and dual-stream jets with fluidic injection on the core stream. The fluidic injection nozzles delivered air to the jet through slots on the interior of the nozzle at the nozzle trailing edge. The investigations include subsonic and supersonic jet conditions. Reductions in broadband shock noise and low frequency mixing noise were obtained with the introduction of fluidic injection on single stream jets. Fluidic injection was found to eliminate shock cells, increase jet mixing, and reduce turbulent kinetic energy levels near the end of the potential core. For dual-stream subsonic jets, the introduction of fluidic injection reduced low frequency noise in the peak jet noise direction and enhanced jet mixing. For dual-stream jets with supersonic fan streams and subsonic core streams, the introduction of fluidic injection in the core stream impacted the jet shock cell structure but had little effect on mixing between the core and fan streams.

  7. Noise Reduction in the Time Domain using Joint Diagonalization

    DEFF Research Database (Denmark)

    Nørholm, Sidsel Marie; Benesty, Jacob; Jensen, Jesper Rindom

    2014-01-01

    , an estimate of the desired signal is found by subtraction of the noise estimate from the observed signal. The filter can be designed to obtain a desired trade-off between noise reduction and signal distortion, depending on the number of eigenvectors included in the filter design. This is explored through...... simulations using a speech signal corrupted by car noise, and the results confirm that the output signal-to-noise ratio and speech distortion index both increase when more eigenvectors are included in the filter design....

  8. Reduction of centrifugal fan noise by use of resonators

    Science.gov (United States)

    Neise, W.; Koopmann, G. H.

    1980-11-01

    A method by which an acoustic resonator can be used to reduce at source the aerodynamic noise generated by turbomachinery has been investigated experimentally. The casing of a small, centrifugal blower was modified by replacing the cut-off of the scroll with the mouth of a quarter-wavelength resonator. The mouth of the resonator was constructed from a series of perforated plates with the same curvature as the cut-off to preserve the original geometry of the casing. Tuning of the resonator was achieved by changing the length via a movable end plug. The noise measurements were made in an anechoically terminated outlet duct at nearly a free delivery operating condition of the blower. With appropriate tuning of the resonator, reductions in the blade passing frequency tones of up to 29 dB were observed with corresponding overall sound pressure levels reductions of up to 7 dB(A). Parameters which influenced the band width of the resonator response were the porosity and the size of the resonator mouth and the flow velocity near the cut-off region. Throughout the tests, the aerodynamic performance of the blower was unaffected by the addition of the resonator to the casing.

  9. Effect of Two Advanced Noise Reduction Technologies on the Aerodynamic Performance of an Ultra High Bypass Ratio Fan

    Science.gov (United States)

    Hughes, Christoper E.; Gazzaniga, John A.

    2013-01-01

    A wind tunnel experiment was conducted in the NASA Glenn Research Center anechoic 9- by 15-Foot Low-Speed Wind Tunnel to investigate two new advanced noise reduction technologies in support of the NASA Fundamental Aeronautics Program Subsonic Fixed Wing Project. The goal of the experiment was to demonstrate the noise reduction potential and effect on fan model performance of the two noise reduction technologies in a scale model Ultra-High Bypass turbofan at simulated takeoff and approach aircraft flight speeds. The two novel noise reduction technologies are called Over-the-Rotor acoustic treatment and Soft Vanes. Both technologies were aimed at modifying the local noise source mechanisms of the fan tip vortex/fan case interaction and the rotor wake-stator interaction. For the Over-the-Rotor acoustic treatment, two noise reduction configurations were investigated. The results showed that the two noise reduction technologies, Over-the-Rotor and Soft Vanes, were able to reduce the noise level of the fan model, but the Over-the-Rotor configurations had a significant negative impact on the fan aerodynamic performance; the loss in fan aerodynamic efficiency was between 2.75 to 8.75 percent, depending on configuration, compared to the conventional solid baseline fan case rubstrip also tested. Performance results with the Soft Vanes showed that there was no measurable change in the corrected fan thrust and a 1.8 percent loss in corrected stator vane thrust, which resulted in a total net thrust loss of approximately 0.5 percent compared with the baseline reference stator vane set.

  10. Application of a TiO2 nanocomposite in earplugs, a case study of noise reduction.

    Science.gov (United States)

    Ibrahimi Ghavamabadi, Leila; Fouladi Dehaghi, Behzad; Hesampour, Morteza; Ahmadi Angali, Kambiz

    2018-03-13

    Use of hearing protection devices (HPDs) has become necessary when other control measures cannot reduce noise to a safe and standard level. In most countries, more effective hearing protection devices are in demand. The aim of this study was to examine the effects of titanium dioxide (TiO 2 ) nanoparticles on noise reduction efficiency in a polyvinyl chloride (PVC) earplug. An S-60 type PVC polymer as main matrix and TiO 2 with 30 nm size were used. PVC/TiO 2 nanocomposite was mixed at a temperature of 160 °C and 40 rounds per minute (rpm) and the samples were prepared with 0, 0.2 and 0.5 wt% of TiO 2 nanoparticle concentrations. Earplug samples with PVC/TiO 2 (0.2, 0.5 wt%) nanoparticles, when compared with raw earplugs, showed almost equal noise attenuation at low frequencies (500- 125 Hz). However, at high frequencies (2-8 kHz), the power of noise reduction of earplugs containing TiO 2 nanoparticles was significantly increased. The results of the present study showed that samples containing nanoparticles of TiO 2 had more noticeable noise reduction abilities at higher frequencies in comparison with samples without the nanoparticles.

  11. Noise in restaurants: levels and mathematical model.

    Science.gov (United States)

    To, Wai Ming; Chung, Andy

    2014-01-01

    Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (L(eq,1-h)) was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  12. Noise in restaurants: Levels and mathematical model

    Directory of Open Access Journals (Sweden)

    Wai Ming To

    2014-01-01

    Full Text Available Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (Leq,1-h was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using Leq,1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.

  13. Reduction of Classroom Noise Levels Using Group Contingencies

    Science.gov (United States)

    Ring, Brandon M.; Sigurdsson, Sigurdur O.; Eubanks, Sean L.; Silverman, Kenneth

    2014-01-01

    The therapeutic workplace is an employment-based abstinence reinforcement intervention for unemployed drug users where trainees receive on-the-job employment skills training in a classroom setting. The study is an extension of prior therapeutic workplace research, which suggested that trainees frequently violated noise standards. Participants…

  14. Dynamical reduction models with general gaussian noises

    International Nuclear Information System (INIS)

    Bassi, Angelo; Ghirardi, GianCarlo

    2002-02-01

    We consider the effect of replacing in stochastic differential equations leading to the dynamical collapse of the statevector, white noise stochastic processes with non white ones. We prove that such a modification can be consistently performed without altering the most interesting features of the previous models. One of the reasons to discuss this matter derives from the desire of being allowed to deal with physical stochastic fields, such as the gravitational one, which cannot give rise to white noises. From our point of view the most relevant motivation for the approach we propose here derives from the fact that in relativistic models the occurrence of white noises is the main responsible for the appearance of untractable divergences. Therefore, one can hope that resorting to non white noises one can overcome such a difficulty. We investigate stochastic equations with non white noises, we discuss their reduction properties and their physical implications. Our analysis has a precise interest not only for the above mentioned subject but also for the general study of dissipative systems and decoherence. (author)

  15. Dynamical reduction models with general Gaussian noises

    International Nuclear Information System (INIS)

    Bassi, Angelo; Ghirardi, GianCarlo

    2002-01-01

    We consider the effect of replacing in stochastic differential equations leading to the dynamical collapse of the state vector, white-noise stochastic processes with nonwhite ones. We prove that such a modification can be consistently performed without altering the most interesting features of the previous models. One of the reasons to discuss this matter derives from the desire of being allowed to deal with physical stochastic fields, such as the gravitational one, which cannot give rise to white noises. From our point of view, the most relevant motivation for the approach we propose here derives from the fact that in relativistic models intractable divergences appear as a consequence of the white nature of the noises. Therefore, one can hope that resorting to nonwhite noises, one can overcome such a difficulty. We investigate stochastic equations with nonwhite noises, we discuss their reduction properties and their physical implications. Our analysis has a precise interest not only for the above-mentioned subject but also for the general study of dissipative systems and decoherence

  16. Entropy as a measure of the noise extent in a two-level quantum feedback controlled system

    Institute of Scientific and Technical Information of China (English)

    Wang Tao-Bo; Fang Mao-Fa; Hu Yao-Hua

    2007-01-01

    By introducing the von Neumann entropy as a measure of the extent of noise, this paper discusses the entropy evolution in a two-level quantum feedback controlled system. The results show that the feedback control can induce the reduction of the degree of noise, and different control schemes exhibit different noise controlling ability, the extent of the reduction also related with the position of the target state on the Bloch sphere. It is shown that the evolution of entropy can provide a real time noise observation and a systematic guideline to make reasonable choice of control strategy.

  17. Effects of directional microphone and adaptive multichannel noise reduction algorithm on cochlear implant performance.

    Science.gov (United States)

    Chung, King; Zeng, Fan-Gang; Acker, Kyle N

    2006-10-01

    Although cochlear implant (CI) users have enjoyed good speech recognition in quiet, they still have difficulties understanding speech in noise. We conducted three experiments to determine whether a directional microphone and an adaptive multichannel noise reduction algorithm could enhance CI performance in noise and whether Speech Transmission Index (STI) can be used to predict CI performance in various acoustic and signal processing conditions. In Experiment I, CI users listened to speech in noise processed by 4 hearing aid settings: omni-directional microphone, omni-directional microphone plus noise reduction, directional microphone, and directional microphone plus noise reduction. The directional microphone significantly improved speech recognition in noise. Both directional microphone and noise reduction algorithm improved overall preference. In Experiment II, normal hearing individuals listened to the recorded speech produced by 4- or 8-channel CI simulations. The 8-channel simulation yielded similar speech recognition results as in Experiment I, whereas the 4-channel simulation produced no significant difference among the 4 settings. In Experiment III, we examined the relationship between STIs and speech recognition. The results suggested that STI could predict actual and simulated CI speech intelligibility with acoustic degradation and the directional microphone, but not the noise reduction algorithm. Implications for intelligibility enhancement are discussed.

  18. Practical ranges of loudness levels of various types of environmental noise, including traffic noise, aircraft noise, and industrial noise

    NARCIS (Netherlands)

    Salomons, E.M.; Janssen, S.A.

    2011-01-01

    In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a

  19. Study of noise reduction characteristics of double-wall panels

    Science.gov (United States)

    Navaneethan, R.; Quayle, B.; Stevenson, S.; Graham, M.

    1983-05-01

    The noise reduction characteristics of general aviation type, flat, double-wall structures were investigated. The experimental study was carried out on 20-by-20 inch panels with an exposed area of 18 by 18 inches. A frequency range from 20 to 5000 Hz was covered. The experimental results, in general, follow the expected trends. At low frequencies the double-wall structures are no better than the single-wall structures. However, for depths normally used in the general aviation industry, the double-wall panels are very attractive. The graphite-spoxy skin panels have higher noise reduction at very low frequencies ( 100 Hz) than the Kevlar skin panels. But the aluminum panels have higher noise reduction in the high frequency region, due to their greater mass. Use of fiberglass insulation is not effective in the low frequency region, and at times it is even negative. But the insulation is effective in the high-frequency region. The theoretical model for predicting the transmission loss of these multilayered panels is also discussed.

  20. Acoustical and Perceptual Comparison of Noise Reduction and Compression in Hearing Aids

    NARCIS (Netherlands)

    Brons, Inge; Houben, Rolph; Dreschler, Wouter A.

    2015-01-01

    Noise reduction and dynamic-range compression are generally applied together in hearing aids but may have opposite effects on amplification. This study evaluated the acoustical and perceptual effects of separate and combined processing of noise reduction and compression. Recordings of the output of

  1. Noise reduction in Arterial Spin Labeling based Functional Connectivity using nuisance variables

    Directory of Open Access Journals (Sweden)

    Kay Jann

    2016-08-01

    Full Text Available Arterial Spin Labeling (ASL perfusion image series have recently been utilized for functional connectivity (FC analysis in healthy volunteers and children with autism spectrum disorders (ASD. Noise reduction by using nuisance variables has been shown to be necessary to minimize potential confounding effects of head motion and physiological signals on BOLD based FC analysis. The purpose of the present study is to systematically evaluate the effectiveness of different noise reduction strategies using nuisance variables to improve perfusion based FC analysis in two cohorts of healthy adults using state of the art 3D background-suppressed (BS GRASE pseudo-continuous ASL (pCASL and dual-echo 2D-EPI pCASL sequences. Five different noise reduction strategies (NRS were performed in healthy volunteers to compare their performance. We then compared seed-based FC analysis using 3D BS GRASE pCASL in a cohort of 12 children with ASD (3f/9m, age 12.8±1.3y and 13 typically developing (TD children (1f/12m; age 13.9±3years in conjunction with noise reduction strategies. Regression of different combinations of nuisance variables affected FC analysis from a seed in the posterior cingulate cortex (PCC to other areas of the default mode network (DMN in both BOLD and pCASL data sets. Consistent with existing literature on BOLD-FC, we observed improved spatial specificity after physiological noise reduction and improved long-range connectivity using head movement related regressors. Furthermore, 3D BS GRASE pCASL shows much higher temporal SNR compared to dual-echo 2D-EPI pCASL and similar effects of noise reduction as those observed for BOLD. Seed-based FC analysis using 3D BS GRASE pCASL children with ASD and TD children showed that noise reduction including physiological and motion related signals as nuisance variables is crucial for identifying altered long-range connectivity from PCC to frontal brain areas associated with ASD. This is the first study that

  2. Modeling speed and width parameters of vehicle tires for prediction of the reduction in vehicle noise pollution

    Directory of Open Access Journals (Sweden)

    Amir Esmael Forouhid

    2016-06-01

    Full Text Available Introduction: Safe driving requires the ability of the driver to receive the messages and complying with them. The most significant consequences of noise pollution are on the human auditory system. Disorders in the auditory system can have harmful side effects for human health. By reducing this kind of pollution in large cities, the quality of life, which is one of the biggest goals of the governments, can be considerably increased. Hence, in the present research, some parameters of vehicle tires were examined as a source of noise pollution, and the results can be taken into consideration in noise pollution reduction. Material and Method: Several vehicles with different tire width were selected for measuring sound level. The sound levels were measured for moving vehicles with the use of the Statistical Pass By Method (SPB, ISO 11819-1. Following sound level measurements for moving vehicles and by considering tire width, mathematical model of noise level was predicted on the basis of the obtained information and by usage of SPSS program and considering vehicle tire parameters. Result: The result of this study showed that the vehicle speed and tire width can affect different sound levels emitted by moving tire on road surface. The average speed of vehicles can play an important role in the noise pollution. By increasing speed, rotation of the the tires on the asphalt is increased, as it is a known factors for noise pollution. Moreover, changing the speed of vehicles is accompanied with abnormal sounds of vehicle engine. According to regression model analysis, the obtained value of R2 for the model is 0.8367 which represents the coefficient of determination. Conclusion: The results suggest the main role of the vehicle speed and tire width in increasing the noise reaches to the drivers and consequent noise pollution, which demonstrates the necessity for noise control measures. According to the obtained model, it is understood that changes in noise

  3. Review of noise reduction methods for centrifugal fans

    Science.gov (United States)

    Neise, W.

    1981-11-01

    Several methods for the reduction of centrifugal fan noise are presented, the most of which are aimed at a lower blade passage frequency level. The methods are grouped into five categories: casing modifications to increase the distance between impeller and cutoff, the introduction of a phase shift of the source pressure fluctuations, impeller modifications, radial clearance between impeller eye and inlet nozzle, and acoustical measures. Resonators mounted at the cutoff of centrifugal fans appear to be a highly efficient and simple means of reducing the blade passage tone, and the method can be used for new fan construction and existing installations without affecting the aerodynamic performance of the fan.

  4. Electronic noise in CT detectors: Impact on image noise and artifacts.

    Science.gov (United States)

    Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H

    2013-10-01

    The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.

  5. A simulation study of harmonics regeneration in noise reduction for electric and acoustic stimulation.

    Science.gov (United States)

    Hu, Yi

    2010-05-01

    Recent research results show that combined electric and acoustic stimulation (EAS) significantly improves speech recognition in noise, and it is generally established that access to the improved F0 representation of target speech, along with the glimpse cues, provide the EAS benefits. Under noisy listening conditions, noise signals degrade these important cues by introducing undesired temporal-frequency components and corrupting harmonics structure. In this study, the potential of combining noise reduction and harmonics regeneration techniques was investigated to further improve speech intelligibility in noise by providing improved beneficial cues for EAS. Three hypotheses were tested: (1) noise reduction methods can improve speech intelligibility in noise for EAS; (2) harmonics regeneration after noise reduction can further improve speech intelligibility in noise for EAS; and (3) harmonics sideband constraints in frequency domain (or equivalently, amplitude modulation in temporal domain), even deterministic ones, can provide additional benefits. Test results demonstrate that combining noise reduction and harmonics regeneration can significantly improve speech recognition in noise for EAS, and it is also beneficial to preserve the harmonics sidebands under adverse listening conditions. This finding warrants further work into the development of algorithms that regenerate harmonics and the related sidebands for EAS processing under noisy conditions.

  6. Experimental demonstration of wind turbine noise reduction through optimized airfoil shape and trailing-edge serrations

    Energy Technology Data Exchange (ETDEWEB)

    Oerlemans, S. [National Aerospace Laboratory NLR, Emmeloord (Netherlands); Schepers, J.G. [Unit Wind Energy, Energy research Centre of the Netherlands ECN, Petten (Netherlands); Guidati, G.; Wagner, S. [Institut fuer Aerodynamik und Gasdynamik IAG, Universitaet Stuttgart (Germany)

    2001-07-15

    The objective of the European project DATA (Design and Testing of Acoustically Optimized Airfoils for Wind Turbines) is a reduction of trailing-edge (TE) noise by modifying the airfoil shape and/or the application of trailing-edge serrations. This paper describes validation measurements that were performed in the DNW-LLF wind tunnel, on a model scale wind turbine with a two-bladed 4.5 m diameter rotor which was designed in the project. Measurements were done for one reference- and two acoustically optimized rotors, for varying flow conditions. The aerodynamic performance of the rotors was measured using a torque meter in the hub, and further aerodynamic information was obtained from flow visualization on the blades. The acoustic measurements were done with a 136 microphone out-of-flow acoustic array. Besides the location of the noise sources in the (stationary) rotor plane, a new acoustic processing method enabled identification of dominant noise source regions on the rotating blades. The results show dominant noise sources at the trailing-edge of the blade, close to the tip. The optimized airfoil shapes result in a significant reduction of TE noise levels with respect to the reference rotor, without loss in power production. A further reduction can be achieved by the application of trailing-edge serrations. The aerodynamic measurements are generally in good agreement with the aerodynamic predictions made during the design of the model turbine.

  7. Reduction of environmental MHz noise for SQUID application

    Energy Technology Data Exchange (ETDEWEB)

    Araya, T. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan)]. E-mail: araya@sup.ee.es.osaka-u.ac.jp; Kitamura, Y. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan); Kamishiro, M. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan); Sakuta, K. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan); Itozaki, H. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan)]. E-mail: itozaki@ee.es.osaka-u.ac.jp

    2006-10-01

    It is important to remove large environmental noise in measurement using SQUIDs without magnetic shielding. Active noise control (ANC) is an effective method to remove the environmental noise. The environmental noise has been reduced by the ANC system in the radio frequency region around MHz. The anti-phase waves of the environmental noise should be generated by this system. The ANC system including the phase and amplitude control circuit was developed to make the anti-phase waves in the MHz region. In this paper, sinusoidal waves with a MHz frequency were used as the environmental noise. When a coil antenna was used for a receiver antenna, this ANC system suppressed these sinusoidal waves to the white noise level about 40 dB. When we used a SQUID as a receiver antenna, we also cancelled sinusoidal waves to the white noise level by this system. This shows that the ANC system is useful to reduce an environmental noise when this ANC system is developed to cancel multi-frequency noise.

  8. Reduction of environmental MHz noise for SQUID application

    International Nuclear Information System (INIS)

    Araya, T.; Kitamura, Y.; Kamishiro, M.; Sakuta, K.; Itozaki, H.

    2006-01-01

    It is important to remove large environmental noise in measurement using SQUIDs without magnetic shielding. Active noise control (ANC) is an effective method to remove the environmental noise. The environmental noise has been reduced by the ANC system in the radio frequency region around MHz. The anti-phase waves of the environmental noise should be generated by this system. The ANC system including the phase and amplitude control circuit was developed to make the anti-phase waves in the MHz region. In this paper, sinusoidal waves with a MHz frequency were used as the environmental noise. When a coil antenna was used for a receiver antenna, this ANC system suppressed these sinusoidal waves to the white noise level about 40 dB. When we used a SQUID as a receiver antenna, we also cancelled sinusoidal waves to the white noise level by this system. This shows that the ANC system is useful to reduce an environmental noise when this ANC system is developed to cancel multi-frequency noise

  9. The effect of multimicrophone noise reduction systems on sound source localization by users of binaural hearing aids.

    Science.gov (United States)

    Van den Bogaert, Tim; Doclo, Simon; Wouters, Jan; Moonen, Marc

    2008-07-01

    This paper evaluates the influence of three multimicrophone noise reduction algorithms on the ability to localize sound sources. Two recently developed noise reduction techniques for binaural hearing aids were evaluated, namely, the binaural multichannel Wiener filter (MWF) and the binaural multichannel Wiener filter with partial noise estimate (MWF-N), together with a dual-monaural adaptive directional microphone (ADM), which is a widely used noise reduction approach in commercial hearing aids. The influence of the different algorithms on perceived sound source localization and their noise reduction performance was evaluated. It is shown that noise reduction algorithms can have a large influence on localization and that (a) the ADM only preserves localization in the forward direction over azimuths where limited or no noise reduction is obtained; (b) the MWF preserves localization of the target speech component but may distort localization of the noise component. The latter is dependent on signal-to-noise ratio and masking effects; (c) the MWF-N enables correct localization of both the speech and the noise components; (d) the statistical Wiener filter approach introduces a better combination of sound source localization and noise reduction performance than the ADM approach.

  10. Noise Reduction Evaluation of Multi-Layered Viscoelastic Infinite Cylinder under Acoustical Wave Excitation

    Directory of Open Access Journals (Sweden)

    M.R. Mofakhami

    2008-01-01

    Full Text Available In this paper sound transmission through the multilayered viscoelastic air filled cylinders subjected to the incident acoustic wave is studied using the technique of separation of variables on the basis of linear three dimensional theory of elasticity. The effect of interior acoustic medium on the mode maps (frequency vs geometry and noise reduction is investigated. The effects of internal absorption and external moving medium on noise reduction are also evaluated. The dynamic viscoelastic properties of the structure are rigorously taken into account with a power law technique that models the viscoelastic damping of the cylinder. A parametric study is also performed for the two layered infinite cylinders to obtain the effect of viscoelastic layer characteristics such as thickness, material type and frequency dependency of viscoelastic properties on the noise reduction. It is shown that using constant and frequency dependent viscoelastic material with high loss factor leads to the uniform noise reduction in the frequency domain. It is also shown that the noise reduction obtained for constant viscoelastic material property is subjected to some errors in the low frequency range with respect to those obtained for the frequency dependent viscoelastic material.

  11. Bit-rate reduction strategies for noise suppression with a remote wireless microphone

    NARCIS (Netherlands)

    Cvijanovic, N.; Sadiq, O.; Srinivasan, S.

    2012-01-01

    In single channel non-stationary noise reduction it is paramount that a good noise reference is available in a timely manner to maintaina high quality speech signal. Using a remote wireless microphone placed close to a noise source, a good estimate of the noise power spectral density (PSD) can be

  12. Bit rate reduction strategies for noise suppression using a remote wireless microphone

    NARCIS (Netherlands)

    Cvijanovic, N.; Sadiq, O.; Srinivasan, S.

    2012-01-01

    In single-channel non-stationary noise reduction it is paramount that a good noise reference is available in a timely manner to maintain a high quality speech signal. Using a remote wireless microphone placed close to a noise source, a good estimate of the noise power spectral density (PSD) can be

  13. Noise reduction methods for nucleic acid and macromolecule sequencing

    Science.gov (United States)

    Schuller, Ivan K.; Di Ventra, Massimiliano; Balatsky, Alexander

    2018-05-08

    Methods, systems, and devices are disclosed for processing macromolecule sequencing data with substantial noise reduction. In one aspect, a method for reducing noise in a sequential measurement of a macromolecule comprising serial subunits includes cross-correlating multiple measured signals of a physical property of subunits of interest of the macromolecule, the multiple measured signals including the time data associated with the measurement of the signal, to remove or at least reduce signal noise that is not in the same frequency and in phase with the systematic signal contribution of the measured signals.

  14. Noise levels, noise annoyance, and hearing-related problems in a dental college.

    Science.gov (United States)

    Ahmed, Hafiz Omer; Ali, Wesal Jasim

    2017-05-04

    Through a cross-sectional survey and integrated sound level meter, this research examined noise exposure and auditory- and nonauditory-related problems experienced by students of a dentistry college located in the United Arab Emirates (UAE). A structured interview questionnaire was used to examine hearing-related problems, noise annoyance, and awareness of 114 students toward noise. The results showed that maximum noise levels were between 65 and 79 dB(A) with peak levels (high and low frequencies) ranging between 89 and 93 dB(A). Around 80% of the students experienced a certain degree of noise annoyance; 54% reported one of the hearing-related problems; and about 10% claimed to have hearing loss to a certain extent. It is recommended that sound-absorbent materials be used during the construction of dental clinics and laboratories to reduce the noise levels.

  15. DFT-Domain Based Single-Microphone Noise Reduction for Speech Enhancement

    DEFF Research Database (Denmark)

    C. Hendriks, Richard; Gerkmann, Timo; Jensen, Jesper

    As speech processing devices like mobile phones, voice controlled devices, and hearing aids have increased in popularity, people expect them to work anywhere and at any time without user intervention. However, the presence of acoustical disturbances limits the use of these applications, degrades...... their performance, or causes the user difficulties in understanding the conversation or appreciating the device. A common way to reduce the effects of such disturbances is through the use of single-microphone noise reduction algorithms for speech enhancement. The field of single-microphone noise reduction...

  16. Application of an active device for helicopter noise reduction in JAXA

    International Nuclear Information System (INIS)

    Saito, Shigeru; Kobiki, Noboru; Tanabe, Yasutada

    2010-01-01

    Important issues in noise problems for current helicopters are described. An active tab (AT) was developed as a new active device for noise/vibration reduction under research cooperation between Japan Aerospace Exploration Agency (JAXA) and Kawada Industries, Inc. The wind tunnel test was conducted in order to investigate the effectiveness of the AT on the aeroacoustic characteristics of a helicopter. From the wind tunnel test, the capability of reducing blade vortex interaction (BVI) noise by an AT was verified. A new control law using instantaneous pressure change on a blade during BVI phenomena was introduced and applied to the wind tunnel testing. This new control law shows reasonable controllability for helicopter noise reduction. Furthermore, in order to analyze noise characteristics, the advanced computational fluid dynamics (CFD) code named JAXA o v3d was developed in JAXA and extended to include CFD-CSD (computational structure dynamics) coupling by using the beam theory for blade deformation. (invited paper)

  17. Helicopter Non-Unique Trim Strategies for Blade-Vortex Interaction (BVI) Noise Reduction

    Science.gov (United States)

    Malpica, Carlos; Greenwood, Eric; Sim, Ben W.

    2016-01-01

    An acoustics parametric analysis of the effect of fuselage drag and pitching moment on the Blade-Vortex Interaction (BVI) noise radiated by a medium lift helicopter (S-70UH-60) in a descending flight condition was conducted. The comprehensive analysis CAMRAD II was used for the calculation of vehicle trim, wake geometry and integrated air loads on the blade. The acoustics prediction code PSU-WOPWOP was used for calculating acoustic pressure signatures for a hemispherical grid centered at the hub. This paper revisits the concept of the X-force controller for BVI noise reduction, and investigates its effectiveness on an S-70 helicopter. The analysis showed that further BVI noise reductions were achievable by controlling the fuselage pitching moment. Reductions in excess of 6 dB of the peak BVI noise radiated towards the ground were demonstrated by compounding the effect of airframe drag and pitching moment simultaneously.

  18. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    International Nuclear Information System (INIS)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta

    2015-01-01

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping

  19. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta, E-mail: paulo.zannin@pesquisador.cnpq.br

    2015-02-15

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping.

  20. Analysis of Beamformer Directed Single-Channel Noise Reduction System for Hearing Aid Applications

    DEFF Research Database (Denmark)

    Jensen, Jesper; Pedersen, Michael Syskind

    2015-01-01

    We study multi-microphone noise reduction systems consisting of a beamformer and a single-channel (SC) noise reduction stage. In particular, we present and analyse a maximum likelihood (ML) method for jointly estimating the target and noise power spectral densities (psd's) entering the SC filter....... We show that the estimators are minimum variance and unbiased, and provide closed-form expressions for their mean-square error (MSE). Furthermore, we show that the MSE of the noise psd estimator is particularly simple: it is independent of target signal characteristics, frequency, and microphone...

  1. Aeroacoustic characteristics and noise reduction of a centrifugal fan for a vacuum cleaner

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Wan Ho; Rew, Ho Seon; Kim, Chang Joon [LG Electronics, Seoul (Korea, Republic of)

    2004-02-01

    The aeroacoustic characteristics of a centrifugal fan for a vacuum cleaner and its noise reduction method are studied in this paper. The major noise source of a vacuum cleaner is the centrifugal fan. The impeller of the fan rotates at over 30000 rpm, and generates very high-level noise. It was revealed that the dominant noise source is the aerodynamic interaction between the rotating impeller and stationary diffuser. The directivity of acoustic pressure showed that most of the noise propagates backward direction of the fan-motor assembly. In order to reduce the high tonal sound generated from the aerodynamic interaction, unevenly pitched impeller and diffuser, and tapered impeller designs were proposed and experiments were performed. Uneven pitch design of the impeller changes the sound quality while the overall Sound Power Level (SPL) and the performance remains similar. The effect of the tapered design of impeller was evaluated. The trailing edge of the tapered fan is inclined. This reduces the flow interaction between the rotating impeller and the stationary diffuser because of some phase shifts. The static efficiency of the new impeller design is slightly lower than the previous design. However, the overall SPL is reduced by about 4 dB(A). The SPL of the fundamental Blade Passing Frequency (BPF) is reduced by about 6 dB(A) and the 2{sup nd} BPF is reduced about 20 dB(A). The vacuum cleaner with the tapered impeller design produces lower noise level than the previous one, and the strong tonal sound was dramatically reduced.

  2. Aeroacoustic characteristics and noise reduction of a centrifugal fan for a vacuum cleaner

    International Nuclear Information System (INIS)

    Jeon, Wan Ho; Rew, Ho Seon; Kim, Chang Joon

    2004-01-01

    The aeroacoustic characteristics of a centrifugal fan for a vacuum cleaner and its noise reduction method are studied in this paper. The major noise source of a vacuum cleaner is the centrifugal fan. The impeller of the fan rotates at over 30000 rpm, and generates very high-level noise. It was revealed that the dominant noise source is the aerodynamic interaction between the rotating impeller and stationary diffuser. The directivity of acoustic pressure showed that most of the noise propagates backward direction of the fan-motor assembly. In order to reduce the high tonal sound generated from the aerodynamic interaction, unevenly pitched impeller and diffuser, and tapered impeller designs were proposed and experiments were performed. Uneven pitch design of the impeller changes the sound quality while the overall Sound Power Level (SPL) and the performance remains similar. The effect of the tapered design of impeller was evaluated. The trailing edge of the tapered fan is inclined. This reduces the flow interaction between the rotating impeller and the stationary diffuser because of some phase shifts. The static efficiency of the new impeller design is slightly lower than the previous design. However, the overall SPL is reduced by about 4 dB(A). The SPL of the fundamental Blade Passing Frequency (BPF) is reduced by about 6 dB(A) and the 2 nd BPF is reduced about 20 dB(A). The vacuum cleaner with the tapered impeller design produces lower noise level than the previous one, and the strong tonal sound was dramatically reduced

  3. Noise Reduction Techniques

    Science.gov (United States)

    Hallas, Tony

    There are two distinct kinds of noise - structural and color. Each requires a specific method of attack to minimize. The great challenge is to reduce the noise without reducing the faint and delicate detail in the image. My most-used and favorite noise suppression is found in Photoshop CS 5 Camera Raw. If I cannot get the desired results with the first choice, I will use Noise Ninja, which has certain advantages in some situations that we will cover.

  4. Prediction and Reduction of Aerodynamic Noise of the Multiblade Centrifugal Fan

    Directory of Open Access Journals (Sweden)

    Shuiqing Zhou

    2014-08-01

    Full Text Available An aerodynamic and aeroacoustic investigation of the multiblade centrifugal fan is proposed in this paper, and a hybrid technique of combining flow field calculation and acoustic analysis is applied to solve the aeroacoustic problem of multiblade centrifugal fan. The unsteady flow field of the multiblade centrifugal fan is predicted by solving the incompressible Reynolds-averaged Navier-Stokes (RANS equations with conventional computing techniques for fluid dynamics. The principal noise source induced is extracted from the calculation of the flow field by using acoustic principles, and the modeled sources on inner and outer surfaces of the volute are calculated with multiregional boundary element method (BEM. Through qualitative analysis, the sound pressure amplitude distribution of the multiblade centrifugal fan in near field is given and the sound pressure level (SPL spectrum diagram of monitoring points in far field is obtained. Based on the analysis results, the volute tongue structure is adjusted and then a low-noise design for the centrifugal fan is proposed. The comparison of noise tests shows the noise reduction of improved fan model is more obvious, which is in good agreement with the prediction using the hybrid techniques.

  5. [Environmental noise levels in 2 intensive care units in a tertiary care centre].

    Science.gov (United States)

    Ornelas-Aguirre, José Manuel; Zárate-Coronado, Olivia; Gaxiola-González, Fabiola; Neyoy-Sombra, Venigna

    2017-04-03

    The World Health Organisation (WHO) has established a maximum noise level of 40 decibels (dB) for an intensive care unit. The aim of this study was to compare the noise levels in 2 different intensive care units at a tertiary care centre. Using a cross-sectional design study, an analysis was made of the maximum noise level was within the intensive coronary care unit and intensive care unit using a digital meter. A measurement was made in 4 different points of each room, with 5minute intervals, for a period of 60minutes 7:30, 14:30, and 20:30. The means of the observations were compared with descriptive statistics and Mann-Whitney U. An analysis with Kruskal-Wallis test was performed to the mean noise level. The noise observed in the intensive care unit had a mean of 64.77±3.33dB (P=.08), which was similar to that in the intensive coronary care unit, with a mean of 60.20±1.58dB (P=.129). Around 25% or more of the measurements exceeded the level recommended by the WHO by up to 20 points. Noise levels measured in intensive care wards exceed the maximum recommended level for a hospital. It is necessary to design and implement actions for greater participation of health personnel in the reduction of environmental noise. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  6. Investigations of internal noise levels for different target sizes, contrasts, and noise structures

    Science.gov (United States)

    Han, Minah; Choi, Shinkook; Baek, Jongduk

    2014-03-01

    To describe internal noise levels for different target sizes, contrasts, and noise structures, Gaussian targets with four different sizes (i.e., standard deviation of 2,4,6 and 8) and three different noise structures(i.e., white, low-pass, and highpass) were generated. The generated noise images were scaled to have standard deviation of 0.15. For each noise type, target contrasts were adjusted to have the same detectability based on NPW, and the detectability of CHO was calculated accordingly. For human observer study, 3 trained observers performed 2AFC detection tasks, and correction rate, Pc, was calculated for each task. By adding proper internal noise level to numerical observer (i.e., NPW and CHO), detectability of human observer was matched with that of numerical observers. Even though target contrasts were adjusted to have the same detectability of NPW observer, detectability of human observer decreases as the target size increases. The internal noise level varies for different target sizes, contrasts, and noise structures, demonstrating different internal noise levels should be considered in numerical observer to predict the detection performance of human observer.

  7. Objective Measures of Listening Effort: Effects of Background Noise and Noise Reduction

    Science.gov (United States)

    Sarampalis, Anastasios; Kalluri, Sridhar; Edwards, Brent; Hafter, Ervin

    2009-01-01

    Purpose: This work is aimed at addressing a seeming contradiction related to the use of noise-reduction (NR) algorithms in hearing aids. The problem is that although some listeners claim a subjective improvement from NR, it has not been shown to improve speech intelligibility, often even making it worse. Method: To address this, the hypothesis…

  8. Detection threshold for sound distortion resulting from noise reduction in normal-hearing and hearing-impaired listeners

    NARCIS (Netherlands)

    Brons, Inge; Dreschler, Wouter A.; Houben, Rolph

    2014-01-01

    Hearing-aid noise reduction should reduce background noise, but not disturb the target speech. This objective is difficult because noise reduction suffers from a trade-off between the amount of noise removed and signal distortion. It is unknown if this important trade-off differs between

  9. Research of noise emission sources in railway transport and effective ways of their reduction

    Directory of Open Access Journals (Sweden)

    Zvolenský Peter

    2017-01-01

    Full Text Available In the EU conditions attention is systematically paid to noise reduction on the railways. Because TSI rules systematically tighten limits for noise emissions from railway vehicles, noise research must be addressed by all Member States, as the main technical solutions for railway vehicles and construction technological aspects of railway operations can result in lower noise exposure of affected areas or objects. The paper focuses on theoretical investigation of sources and paths of sound propagation, possibilities of noise reduction both on vehicles and by infrastructure and experimental measurements of the situation in transport practice. Methodology for reducing railway noise around tracks has been presented, too.

  10. Optimization of the poro-serrated trailing edges for airfoil broadband noise reduction.

    Science.gov (United States)

    Chong, Tze Pei; Dubois, Elisa

    2016-08-01

    This paper reports an aeroacoustic investigation of a NACA0012 airfoil with a number of poro-serrated trailing edge devices that contain porous materials of various air flow resistances at the gaps between adjacent members of the serrated-sawtooth trailing edge. The main objective of this work is to determine whether multiple-mechanisms on the broadband noise reduction can co-exist on a poro-serrated trailing edge. When the sawtooth gaps are filled with porous material of low-flow resistivity, the vortex shedding tone at low-frequency could not be completely suppressed at high-velocity, but a reasonably good broadband noise reduction can be achieved at high-frequency. When the sawtooth gaps are filled with porous material of very high-flow resistivity, no vortex shedding tone is present, but the serration effect on the broadband noise reduction becomes less effective. An optimal choice of the flow resistivity for a poro-serrated configuration has been identified, where it can surpass the conventional serrated trailing edge of the same geometry by achieving a further 1.5 dB reduction in the broadband noise while completely suppressing the vortex shedding tone. A weakened turbulent boundary layer noise scattering at the poro-serrated trailing edge is reflected by the lower-turbulence intensity at the near wake centreline across the whole spanwise wavelength of the sawtooth.

  11. Gene regulation and noise reduction by coupling of stochastic processes

    Science.gov (United States)

    Ramos, Alexandre F.; Hornos, José Eduardo M.; Reinitz, John

    2015-02-01

    Here we characterize the low-noise regime of a stochastic model for a negative self-regulating binary gene. The model has two stochastic variables, the protein number and the state of the gene. Each state of the gene behaves as a protein source governed by a Poisson process. The coupling between the two gene states depends on protein number. This fact has a very important implication: There exist protein production regimes characterized by sub-Poissonian noise because of negative covariance between the two stochastic variables of the model. Hence the protein numbers obey a probability distribution that has a peak that is sharper than those of the two coupled Poisson processes that are combined to produce it. Biochemically, the noise reduction in protein number occurs when the switching of the genetic state is more rapid than protein synthesis or degradation. We consider the chemical reaction rates necessary for Poisson and sub-Poisson processes in prokaryotes and eucaryotes. Our results suggest that the coupling of multiple stochastic processes in a negative covariance regime might be a widespread mechanism for noise reduction.

  12. Gene regulation and noise reduction by coupling of stochastic processes.

    Science.gov (United States)

    Ramos, Alexandre F; Hornos, José Eduardo M; Reinitz, John

    2015-02-01

    Here we characterize the low-noise regime of a stochastic model for a negative self-regulating binary gene. The model has two stochastic variables, the protein number and the state of the gene. Each state of the gene behaves as a protein source governed by a Poisson process. The coupling between the two gene states depends on protein number. This fact has a very important implication: There exist protein production regimes characterized by sub-Poissonian noise because of negative covariance between the two stochastic variables of the model. Hence the protein numbers obey a probability distribution that has a peak that is sharper than those of the two coupled Poisson processes that are combined to produce it. Biochemically, the noise reduction in protein number occurs when the switching of the genetic state is more rapid than protein synthesis or degradation. We consider the chemical reaction rates necessary for Poisson and sub-Poisson processes in prokaryotes and eucaryotes. Our results suggest that the coupling of multiple stochastic processes in a negative covariance regime might be a widespread mechanism for noise reduction.

  13. Objective measures of listening effort: effects of background noise and noise reduction.

    Science.gov (United States)

    Sarampalis, Anastasios; Kalluri, Sridhar; Edwards, Brent; Hafter, Ervin

    2009-10-01

    This work is aimed at addressing a seeming contradiction related to the use of noise-reduction (NR) algorithms in hearing aids. The problem is that although some listeners claim a subjective improvement from NR, it has not been shown to improve speech intelligibility, often even making it worse. To address this, the hypothesis tested here is that the positive effects of NR might be to reduce cognitive effort directed toward speech reception, making it available for other tasks. Normal-hearing individuals participated in 2 dual-task experiments, in which 1 task was to report sentences or words in noise set to various signal-to-noise ratios. Secondary tasks involved either holding words in short-term memory or responding in a complex visual reaction-time task. At low values of signal-to-noise ratio, although NR had no positive effect on speech reception thresholds, it led to better performance on the word-memory task and quicker responses in visual reaction times. Results from both dual tasks support the hypothesis that NR reduces listening effort and frees up cognitive resources for other tasks. Future hearing aid research should incorporate objective measurements of cognitive benefits.

  14. A noise-reduction program in a pediatric operation theatre is associated with surgeon's benefits and a reduced rate of complications: a prospective controlled clinical trial.

    Science.gov (United States)

    Engelmann, Carsten R; Neis, Jan Philipp; Kirschbaum, Clemens; Grote, Gudela; Ure, Benno M

    2014-05-01

    We assessed the impact of a noise-reduction program in a pediatric operating theatre. Adverse effects from noise pollution in theatres have been demonstrated. In 156 operations spatially resolved, sound levels were measured before and after a noise-reduction program on the basis of education, rules, and technical devices (Sound Ear). Surgical complications were recorded. The surgeon's biometric (saliva cortisol, electrodermal activity) and behavioral stress responses (questionnaires) were measured and correlated with mission protocols and individual noise sensitivity. Median noise levels in the control group versus the interventional group were reduced by -3 ± 3 dB(A) (63 vs 59 dB(A), P 0.05). Spontaneous noise during pediatric operations attains the magnitude of a lawn mower and peaks resemble a passing truck. The sound intensity could be reduced by 50% by specific measures. This reduction was associated with a significantly lowered number of postoperative complications. The surgeon's benefits are idiosyncratic with "responders" experiencing marked improvements.

  15. Reduction of Poisson noise in measured time-resolved data for time-domain diffuse optical tomography.

    Science.gov (United States)

    Okawa, S; Endo, Y; Hoshi, Y; Yamada, Y

    2012-01-01

    A method to reduce noise for time-domain diffuse optical tomography (DOT) is proposed. Poisson noise which contaminates time-resolved photon counting data is reduced by use of maximum a posteriori estimation. The noise-free data are modeled as a Markov random process, and the measured time-resolved data are assumed as Poisson distributed random variables. The posterior probability of the occurrence of the noise-free data is formulated. By maximizing the probability, the noise-free data are estimated, and the Poisson noise is reduced as a result. The performances of the Poisson noise reduction are demonstrated in some experiments of the image reconstruction of time-domain DOT. In simulations, the proposed method reduces the relative error between the noise-free and noisy data to about one thirtieth, and the reconstructed DOT image was smoothed by the proposed noise reduction. The variance of the reconstructed absorption coefficients decreased by 22% in a phantom experiment. The quality of DOT, which can be applied to breast cancer screening etc., is improved by the proposed noise reduction.

  16. Nuisance levels of noise effects radiologists' performance

    Science.gov (United States)

    McEntee, Mark F.; Coffey, Amina; Ryan, John; O'Beirne, Aaron; Toomey, Rachel; Evanoff, Micheal; Manning, David; Brennan, Patrick C.

    2010-02-01

    This study aimed to measure the sound levels in Irish x-ray departments. The study then established whether these levels of noise have an impact on radiologists performance Noise levels were recorded 10 times within each of 14 environments in 4 hospitals, 11 of which were locations where radiologic images are judged. Thirty chest images were then presented to 26 senior radiologists, who were asked to detect up to three nodular lesions within 30 posteroanterior chest x-ray images in the absence and presence of noise at amplitude demonstrated in the clinical environment. The results demonstrated that noise amplitudes rarely exceeded that encountered with normal conversation with the maximum mean value for an image-viewing environment being 56.1 dB. This level of noise had no impact on the ability of radiologists to identify chest lesions with figure of merits of 0.68, 0.69, and 0.68 with noise and 0.65, 0.68, and 0.67 without noise for chest radiologists, non-chest radiologists, and all radiologists, respectively. the difference in their performance using the DBM MRMC method was significantly better with noise than in the absence of noise at the 90% confidence interval (p=0.077). Further studies are required to establish whether other aspects of diagnosis are impaired such as recall and attention and the effects of more unexpected noise on performance.

  17. The reduction of noise from hydraulic equipments; La reduction du bruit provenant des equipements hydrauliques

    Energy Technology Data Exchange (ETDEWEB)

    Gential, R.

    1996-09-01

    Noise pollution from hydraulic equipments (bath filling, toilets taps, waste waters flow, vibrations, knocks in water pipes, dilatation clattering in heating pipes, hissing of heater taps etc..) are one of the principal causes of nuisance inside residential buildings. Solutions exist and consist in the replacement of old cocks and fittings, the use of soundproof clamps for pipes and noise absorbing supports for baths etc.. This paper summarizes the available modern equipments with a low-noise warranty (cocks and fittings, noise dampers, anti-backflow valves, pressure reducers) and the practical solutions for the modification of existing installations (increase of pipe diameters, reduction of pipe lengths, use of flexible fittings, hydraulic counterbalancing of water flows in heaters etc..). (J.S.)

  18. Noise pollution levels in the pediatric intensive care unit.

    Science.gov (United States)

    Kramer, Bree; Joshi, Prashant; Heard, Christopher

    2016-12-01

    Patients and staff may experience adverse effects from exposure to noise. This study assessed noise levels in the pediatric intensive care unit and evaluated family and staff opinion of noise. Noise levels were recorded using a NoisePro DLX. The microphone was 1 m from the patient's head. The noise level was averaged each minute and levels above 70 and 80 dBA were recorded. The maximum, minimum, and average decibel levels were calculated and peak noise level great than 100 dBA was also recorded. A parent questionnaire concerning their evaluation of noisiness of the bedside was completed. The bedside nurse also completed a questionnaire. The average maximum dB for all patients was 82.2. The average minimum dB was 50.9. The average daily bedside noise level was 62.9 dBA. The average % time where the noise level was higher than 70 dBA was 2.2%. The average percent of time that the noise level was higher than 80 dBA was 0.1%. Patients experienced an average of 115 min/d where peak noise was greater than 100 dBA. The parents and staff identified the monitors as the major contribution to noise. Patients experienced levels of noise greater than 80 dBA. Patients experience peak noise levels in excess of 100 dB during their pediatric intensive care unit stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction.

    Science.gov (United States)

    Ricketts, Todd A; Hornsby, Benjamin W Y

    2005-05-01

    This brief report discusses the affect of digital noise reduction (DNR) processing on aided speech recognition and sound quality measures in 14 adults fitted with a commercial hearing aid. Measures of speech recognition and sound quality were obtained in two different speech-in-noise conditions (71 dBA speech, +6 dB SNR and 75 dBA speech, +1 dB SNR). The results revealed that the presence or absence of DNR processing did not impact speech recognition in noise (either positively or negatively). Paired comparisons of sound quality for the same speech in noise signals, however, revealed a strong preference for DNR processing. These data suggest that at least one implementation of DNR processing is capable of providing improved sound quality, for speech in noise, in the absence of improved speech recognition.

  20. Improved multi-microphone noise reduction preserving binaural cues

    NARCIS (Netherlands)

    Koutrouvelis, A.; Hendriks, R.C.; Jensen, J; Heusdens, R.; Dong, Min; Zheng, Thomas Fang

    2016-01-01

    We propose a new multi-microphone noise reduction technique for binaural cue preservation of the desired source and the interferers. This method is based on the linearly constrained minimum variance (LCMV) framework, where the constraints are used for the binaural cue preservation of the desired

  1. Noise pollution of air compressor and its noise reduction procedures by using an enclosure

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2012-01-01

    Conclusions: An overall noise reduction by 25 dB with the use of mineral wool as an extra liner on the inside of the enclosure, suggests that the effectiveness of the enclosure can be increased by using such absorber materials.

  2. Existing Noise Level at Railway Stations in Malaysia

    Directory of Open Access Journals (Sweden)

    Shahidan Shahiron

    2017-01-01

    Full Text Available Railway transportation known as one of the most environmental friendly transportation mode. However, the significance problems of railway transportation are noise pollution and negatively impact the wellbeing of the whole community. Unfortunately, there has been lack of public awareness about the noise level produce by the railway transportation in Malaysia. This study investigates the noise level produced by railway transportation in Malaysia specifically by Keretapi Tanah Melayu Berhad (KTMB. Methods of collecting existing noise level at railway stations in Malaysia are briefly discussed in this study. The finding indicates that the noise level produced by the railway transportation in Malaysia which is by KTMB is considered as dangerous to human being and also exceed the noise limit that has been assigned by Department of Environment Ministry of Natural Resources and Environment of Malaysia. A better noise barrier and improved material should be developed to mitigate the existing noise level produced by railway transportations in Malaysia.

  3. Active Noise Control for Dishwasher noise

    Science.gov (United States)

    Lee, Nokhaeng; Park, Youngjin

    2016-09-01

    The dishwasher is a useful home appliance and continually used for automatically washing dishes. It's commonly placed in the kitchen with built-in style for practicality and better use of space. In this environment, people are easily exposed to dishwasher noise, so it is an important issue for the consumers, especially for the people living in open and narrow space. Recently, the sound power levels of the noise are about 40 - 50 dBA. It could be achieved by removal of noise sources and passive means of insulating acoustical path. For more reduction, such a quiet mode with the lower speed of cycle has been introduced, but this deteriorates the washing capacity. Under this background, we propose active noise control for dishwasher noise. It is observed that the noise is propagating mainly from the lower part of the front side. Control speakers are placed in the part for the collocation. Observation part of estimating sound field distribution and control part of generating the anti-noise are designed for active noise control. Simulation result shows proposed active noise control scheme could have a potential application for dishwasher noise reduction.

  4. Minimizing noise in fiberglass aquaculture tanks: Noise reduction potential of various retrofits

    Science.gov (United States)

    Equipment used in intensive aquaculture systems, such as pumps and blowers can produce underwater sound levels and frequencies within the range of fish hearing. The impacts of underwater noise on fish are not well known, but limited research suggests that subjecting fish to noise could result in imp...

  5. A Third-Generation Adaptive Statistical Iterative Reconstruction Technique: Phantom Study of Image Noise, Spatial Resolution, Lesion Detectability, and Dose Reduction Potential.

    Science.gov (United States)

    Euler, André; Solomon, Justin; Marin, Daniele; Nelson, Rendon C; Samei, Ehsan

    2018-06-01

    The purpose of this study was to assess image noise, spatial resolution, lesion detectability, and the dose reduction potential of a proprietary third-generation adaptive statistical iterative reconstruction (ASIR-V) technique. A phantom representing five different body sizes (12-37 cm) and a contrast-detail phantom containing lesions of five low-contrast levels (5-20 HU) and three sizes (2-6 mm) were deployed. Both phantoms were scanned on a 256-MDCT scanner at six different radiation doses (1.25-10 mGy). Images were reconstructed with filtered back projection (FBP), ASIR-V with 50% blending with FBP (ASIR-V 50%), and ASIR-V without blending (ASIR-V 100%). In the first phantom, noise properties were assessed by noise power spectrum analysis. Spatial resolution properties were measured by use of task transfer functions for objects of different contrasts. Noise magnitude, noise texture, and resolution were compared between the three groups. In the second phantom, low-contrast detectability was assessed by nine human readers independently for each condition. The dose reduction potential of ASIR-V was estimated on the basis of a generalized linear statistical regression model. On average, image noise was reduced 37.3% with ASIR-V 50% and 71.5% with ASIR-V 100% compared with FBP. ASIR-V shifted the noise power spectrum toward lower frequencies compared with FBP. The spatial resolution of ASIR-V was equivalent or slightly superior to that of FBP, except for the low-contrast object, which had lower resolution. Lesion detection significantly increased with both ASIR-V levels (p = 0.001), with an estimated radiation dose reduction potential of 15% ± 5% (SD) for ASIR-V 50% and 31% ± 9% for ASIR-V 100%. ASIR-V reduced image noise and improved lesion detection compared with FBP and had potential for radiation dose reduction while preserving low-contrast detectability.

  6. Noise Reduction of Ocean-Bottom Pressure Data Toward Real-Time Tsunami Forecasting

    Science.gov (United States)

    Tsushima, H.; Hino, R.

    2008-12-01

    We discuss a method of noise reduction of ocean-bottom pressure data to be fed into the near-field tsunami forecasting scheme proposed by Tsushima et al. [2008a]. In their scheme, the pressure data is processed in real time as follows: (1) removing ocean tide components by subtracting the sea-level variation computed from a theoretical tide model, (2) applying low-pass digital filter to remove high-frequency fluctuation due to seismic waves, and (3) removing DC-offset and linear-trend component to determine a baseline of relative sea level. However, it turns out this simple method is not always successful in extracting tsunami waveforms from the data, when the observed amplitude is ~1cm. For disaster mitigation, accurate forecasting of small tsunamis is important as well as large tsunamis. Since small tsunami events occur frequently, successful tsunami forecasting of those events are critical to obtain public reliance upon tsunami warnings. As a test case, we applied the data-processing described above to the bottom pressure records containing tsunami with amplitude less than 1 cm which was generated by the 2003 Off-Fukushima earthquake occurring in the Japan Trench subduction zone. The observed pressure variation due to the ocean tide is well explained by the calculated tide signals from NAO99Jb model [Matsumoto et al., 2000]. However, the tide components estimated by BAYTAP-G [Tamura et al., 1991] from the pressure data is more appropriate for predicting and removing the ocean tide signals. In the pressure data after removing the tide variations, there remain pressure fluctuations with frequencies ranging from about 0.1 to 1 mHz and with amplitudes around ~10 cm. These fluctuations distort the estimation of zero-level and linear trend to define relative sea-level variation, which is treated as tsunami waveform in the subsequent analysis. Since the linear trend is estimated from the data prior to the origin time of the earthquake, an artificial linear trend is

  7. [Preventive effects of sound insulation windows on the indoor noise levels in a street residential building in Beijing].

    Science.gov (United States)

    Guo, Bin; Huang, Jing; Guo, Xin-biao

    2015-06-18

    To evaluate the preventive effects of sound insulation windows on traffic noise. Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared. The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (Pwindows had significant influence on the indoor noise levels (Pwindow, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads. Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.

  8. Investigation and reduction of excess low-frequency noise in rf superconducting quantum interference devices

    International Nuclear Information System (INIS)

    Mueck, M.; Heiden, C.; Clarke, J.

    1994-01-01

    A detailed study has been made of the low-frequency excess noise of rf superconducting quantum interference devices (SQUIDs), fabricated from thin niobium films and operated at 4.2 K, with rf bias frequencies of 0.15, 1.7, and 3 GHz. When the SQUIDs were operated in an open-loop configuration in the absence of low-frequency flux modulation, the demodulated rf voltage exhibited a substantial level 1/f noise, which was essentially independent of the rf bias frequency. As the rf bias frequency was increased, the crossover frequency at which the 1/f noise power was equal to the white noise power moved to higher frequencies, because of the reduction in white noise. On the other hand, when the SQUID was flux modulated at 50 kHz and operated in a flux locked loop, no 1/f noise was observed at frequencies above 0.5 Hz. A detailed description of how the combination of rf bias and flux modulation removes 1/f noise due to critical current fluctuations is given. Thus, the results demonstrate that the 1/f noise observed in these SQUIDs is generated by critical current fluctuations, rather than by the hopping of flux vortices in the niobium films

  9. Optimal Height Calculation and Modelling of Noise Barrier

    Directory of Open Access Journals (Sweden)

    Raimondas Grubliauskas

    2011-04-01

    Full Text Available Transport is one of the main sources of noise having a particularly strong negative impact on the environment. In the city, one of the best methods to reduce the spread of noise in residential areas is a noise barrier. The article presents noise reduction barrier adaptation with empirical formulas calculating and modelling noise distribution. The simulation of noise dispersion has been performed applying the CadnaA program that allows modelling the noise levels of various developments under changing conditions. Calculation and simulation is obtained by assessing the level of noise reduction using the same variables. The investigation results are presented as noise distribution isolines. The selection of a different height of noise barriers are the results calculated at the heights of 1, 4 and 15 meters. The level of noise reduction at the maximum overlap of data, calculation and simulation has reached about 10%.Article in Lithuanian

  10. High level white noise generator

    International Nuclear Information System (INIS)

    Borkowski, C.J.; Blalock, T.V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application

  11. High level white noise generator

    Science.gov (United States)

    Borkowski, Casimer J.; Blalock, Theron V.

    1979-01-01

    A wide band, stable, random noise source with a high and well-defined output power spectral density is provided which may be used for accurate calibration of Johnson Noise Power Thermometers (JNPT) and other applications requiring a stable, wide band, well-defined noise power spectral density. The noise source is based on the fact that the open-circuit thermal noise voltage of a feedback resistor, connecting the output to the input of a special inverting amplifier, is available at the amplifier output from an equivalent low output impedance caused by the feedback mechanism. The noise power spectral density level at the noise source output is equivalent to the density of the open-circuit thermal noise or a 100 ohm resistor at a temperature of approximately 64,000 Kelvins. The noise source has an output power spectral density that is flat to within 0.1% (0.0043 db) in the frequency range of from 1 KHz to 100 KHz which brackets typical passbands of the signal-processing channels of JNPT's. Two embodiments, one of higher accuracy that is suitable for use as a standards instrument and another that is particularly adapted for ambient temperature operation, are illustrated in this application.

  12. Identification and Reduction of Turbomachinery Noise, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Communities near airports are often exposed to high noise levels due to low flying aircraft in the takeoff and landing phases of flight. Propulsion source noise is...

  13. Railway noise reduction by the application of CHFC material on the rail

    Directory of Open Access Journals (Sweden)

    Brigita ALTENBAHER

    2015-06-01

    Full Text Available Traffic is the most widespread source of environmental noise. Railway noise has become increasingly common in urban areas in the past few decades. Therefore environmental requirements for railway operations regarding noise are becoming very strict and will become even tighter in future. In the present paper we present actual track-based field test performed on Slovenian Railways. The significant noise reduction (up to 30dBA was achieved by the application of CHFC material on the rail using CL-E1 top anti noise system.

  14. Fan interaction noise reduction using a wake generator: experiments and computational aeroacoustics

    Science.gov (United States)

    Polacsek, C.; Desbois-Lavergne, F.

    2003-08-01

    A control grid (wake generator) aimed at reducing rotor-stator interaction modes in fan engines when mounted upstream of the rotor has been studied here. This device complements other active noise control systems currently proposed. The compressor model of the instrumented ONERA CERF-rig is used to simulate suitable conditions. The design of the grid is drafted out using semi-empirical models for wake and potential flow, and experimentally achieved. Cylindrical rods are able to generate a spinning mode of the same order and similar level as the interaction mode. Mounting the rods on a rotating ring allows for adjusting the phase of the control mode so that an 8 dB sound pressure level (SPL) reduction at the blade passing frequency is achieved when the two modes are out of phase. Experimental results are assessed by a numerical approach using computational fluid dynamics (CFD). A Reynolds averaged Navier-Stokes 2-D solver, developed at ONERA, is used to provide the unsteady force components on blades and vanes required for acoustics. The loading noise source term of the Ffowcs Williams and Hawkings equation is used to model the interaction noise between the sources, and an original coupling to a boundary element method (BEM) code is realized to take account of the inlet geometry effects on acoustic in-duct propagation. Calculations using the classical analytical the Green function of an infinite annular duct are also addressed. Simple formulations written in the frequency domain and expanded into modes are addressed and used to compute an in-duct interaction mode and to compare with the noise reduction obtained during the tests. A fairly good agreement between predicted and measured SPL is found when the inlet geometry effects are part of the solution (by coupling with the BEM). Furthermore, computed aerodynamic penalties due to the rods are found to be negligible. These results partly validate the computation chain and highlight the potential of the wake generator

  15. Effect of digital noise reduction on the accuracy of endodontic file length determination

    International Nuclear Information System (INIS)

    Mehdizadeh, Mojdeh; Khademi, Abbas Ali; Shokraneh, Ali; Farhadi, Nastaran

    2013-01-01

    The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO no.08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (a=0.05). Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P 0.05). Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

  16. Reduction of noise in the neonatal intensive care unit using sound-activated noise meters.

    Science.gov (United States)

    Wang, D; Aubertin, C; Barrowman, N; Moreau, K; Dunn, S; Harrold, J

    2014-11-01

    To determine if sound-activated noise meters providing direct audit and visual feedback can reduce sound levels in a level 3 neonatal intensive care unit (NICU). Sound levels (in dB) were compared between a 2-month period with noise meters present but without visual signal fluctuation and a subsequent 2 months with the noise meters providing direct audit and visual feedback. There was a significant increase in the percentage of time the sound level in the NICU was below 50 dB across all patient care areas (9.9%, 8.9% and 7.3%). This improvement was not observed in the desk area where there are no admitted patients. There was no change in the percentage of time the NICU was below 45 or 55 dB. Sound-activated noise meters seem effective in reducing sound levels in patient care areas. Conversations may have moved to non-patient care areas preventing a similar change there. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. The Assessment of Noise Exposure and Noise Annoyance at a Petrochemical Company

    Directory of Open Access Journals (Sweden)

    S. Farhang Dehghan

    2013-12-01

    .Conclusion: Based on the obtained results of investigating the noise level (objective exposure as well as the noise annoyance (subjective exposure at the studied company, it is necessary to adopt the management –technical noise reduction measures at manufacturing sectors as the personal noise exposure and environmental noise exposure and also noise personal exposure of administrative staff can be decreased.

  18. Low-Frequency Noise Reduction by Earmuffs with Flax Fibre-Reinforced Polypropylene Ear Cups

    Directory of Open Access Journals (Sweden)

    Linus Yinn Leng Ang

    2018-01-01

    Full Text Available Soldiers and supporting engineers are frequently exposed to high low-frequency (<500 Hz cabin noise in military vehicles. Despite the use of commercial hearing protection devices, the risk of auditory damage is still imminent because the devices may not be optimally customised for such applications. This study considers flax fibre-reinforced polypropylene (Flax-PP as an alternative to the material selection for the ear cups of commercial earmuffs, which are typically made of acrylonitrile butadiene styrene (ABS. Different weaving configurations (woven and nonwoven and various noise environments (pink noise, cabin booming noise, and firing noise were considered to investigate the feasibility of the proposed composite earmuffs for low-frequency noise reduction. The remaining assembly components of the earmuff were kept consistent with those of a commercial earmuff, which served as a benchmark for results comparison. In contrast to the commercial earmuff, the composite earmuffs were shown to be better in mitigating low-frequency noise by up to 16.6 dB, while compromising midfrequency acoustical performance. Consequently, the proposed composite earmuffs may be an alternative for low-frequency noise reduction in vehicle cabins, at airports, and at construction sites involving heavy machineries.

  19. Study of performance of acoustic fixture for using in noise reduction rate tests of hearing protection devices

    Directory of Open Access Journals (Sweden)

    zam Biabani

    2016-06-01

    Full Text Available Introduction:One of the recommended methods for evaluation effectiveness of hearing protection is use the acoustic fixture accordance with standard ISO 4869-3. The aim of this study was evaluate the acoustic performance of fixture for using in noise reduction rate tests of hearing protection devices in the laboratory. Methods: In this cross-sectional study , noise reduction rates of five common ear muffs used in the Iran industries were investigated based on the ISO 11904 standard, microphone in real ear method, using noise dosimeter (SVANTEK , Model SV102 equipped with microphone SV25 model which can install inside the ear on 30 subjects under laboratory conditions. Also, noise reduction rate of earmuffs was determined using the fixture model AVASINA9402 accordance with standard procedures. Data were analyzed using the software SPSS21. Results: The results showed the real noise reduction rates of the earmuffs on the studied subjects are from 59% to 94% nominal reduction rates. That rates for the ear muffs on the studied fixture are from 64% to 92.The results showed that the noise reduction rates of the ear muffs on subjects compared with and noise reduction rates of the ear muffs on fixture were not statistically significant (p> 0.05. Conclusion: The results showed the accuracy of noise reduction rate of earmuffs using the fixture compared with real subjects is acceptable. Hence, the fixture is good choice for environments where there’s no possibility of acoustic evaluation on real subjects, also for quality control of productions in the earmuff manufacturers.

  20. Mobility and Noise Pollution. Noise-reduction Traditional Strategies and Green Mobility Ones

    Directory of Open Access Journals (Sweden)

    Carmela Gargiulo

    2011-07-01

    Full Text Available The urbanized territories are quite complex environments in many ways, whose management requires, on the one hand, adequate skills to mediate among the different needs, often conflicting, and on the other hand a clear idea of the target to hit.One of these aspects is the need to ensure mobility in urban areas and, simultaneously, reduce noise levels below the values   that are compatible with the well-being of citizens.There are several sources of noise in an urban context  such as vehicle and rail traffic, the fixed sound sources due to craft and trade activities, as well as to equipment for buildings, to human activities related to recreation and tourism.It must be emphasized, however, that not all noise content has a negative value but there are noise sources such as the noise produced by the local markets and/or that produced by craft activities with historical value, the noise, or rather, the sounds perceived in public parks, town centres and/or areas on the sea which, on the contrary, have a positive value.They represent, in fact, the set of sounds that contribute to the perception of the “soundscape” of an area, which are to be preserved as they are not only appreciated but also sought after by citizens.The noise generated by vehicle traffic, however, while not disregarding the contribution to noise pollution produced by other infrastructure for mobility in urban area, represents one of the major contributor to the noise levels recorded in urban areas, disturbing, firstly, people exposed to it and, secondly, masking the perception of pleasant sounds by altering the “soundscape” of the area.In this context, strategies and interventions to reduce noise caused by road traffic, both the traditional ones (regulations on vehicles, circulation, road, city planning and the new ones related to green mobility, have a twofold purpose as they not only reduce the amount of noise generated by road traffic, but at the same time, help to bring

  1. CT urography in the urinary bladder: To compare excretory phase images using a low noise index and a high noise index with adaptive noise reduction filter

    International Nuclear Information System (INIS)

    Takeyama, Nobuyuki; Hayashi, Takaki; Ohgiya, Yoshimitsu

    2011-01-01

    Background: Although CT urography (CTU) is widely used for the evaluation of the entire urinary tract, the most important drawback is the radiation exposure. Purpose: To evaluate the effect of a noise reduction filter (NRF) using a phantom and to quantitatively and qualitatively compare excretory phase (EP) images using a low noise index (NI) with those using a high NI and postprocessing NRF (pNRF). Material and Methods: Each NI value was defined for a slice thickness of 5 mm, and reconstructed images with a slice thickness of 1.25 mm were assessed. Sixty patients who were at high risk of developing bladder tumors (BT) were divided into two groups according to whether their EP images were obtained using an NI of 9.88 (29 patients; group A) or an NI of 20 and pNRF (31 patients; group B). The CT dose index volume (CTDI vol ) and the contrast-to-noise ratio (CNR) of the bladder with respect to the anterior pelvic fat were compared in both groups. Qualitative assessment of the urinary bladder for image noise, sharpness, streak artifacts, homogeneity, and the conspicuity of polypoid or sessile-shaped BTs with a short-axis diameter greater than 10 mm was performed using a 3-point scale. Results: The phantom study showed noise reduction of approximately 40% and 76% dose reduction between group A and group B. CTDI vol demonstrated a 73% reduction in group B (4.6 ± 1.1 mGy) compared with group A (16.9 ± 3.4 mGy). The CNR value was not significantly different (P = 0.60) between group A (16.1 ± 5.1) and group B (16.6 ± 7.6). Although group A was superior (P < 0.01) to group B with regard to image noise, other qualitative analyses did not show significant differences. Conclusion: EP images using a high NI and pNRF were quantitatively and qualitatively comparable to those using a low NI, except with regard to image noise

  2. Phonon squeezed states: quantum noise reduction in solids

    Science.gov (United States)

    Hu, Xuedong; Nori, Franco

    1999-03-01

    This article discusses quantum fluctuation properties of a crystal lattice, and in particular, phonon squeezed states. Squeezed states of phonons allow a reduction in the quantum fluctuations of the atomic displacements to below the zero-point quantum noise level of coherent phonon states. Here we discuss our studies of both continuous-wave and impulsive second-order Raman scattering mechanisms. The later approach was used to experimentally suppress (by one part in a million) fluctuations in phonons. We calculate the expectation values and fluctuations of both the atomic displacement and the lattice amplitude operators, as well as the effects of the phonon squeezed states on macroscopically measurable quantities, such as changes in the dielectric constant. These results are compared with recent experiments. Further information, including preprints and animations, are available in http://www-personal.engin.umich.edu/∼nori/squeezed.html.

  3. A bulk-controlled ring-VCO with 1/f-noise reduction for frequency ΔΣ modulator

    DEFF Research Database (Denmark)

    Tuan Vu, CAO; Wisland, Dag T.; Lande, Tor Sverre

    The paper introduces a bulk-controlled ring-VCO with a tail transistor utilizing flicker-noise (1/f-noise) reduction techniques for a frequency-based DeltaSigma modulator (FDSM). This VCO converts an analog input voltage to phase information under various bias conditions ranging from sub-threshol......The paper introduces a bulk-controlled ring-VCO with a tail transistor utilizing flicker-noise (1/f-noise) reduction techniques for a frequency-based DeltaSigma modulator (FDSM). This VCO converts an analog input voltage to phase information under various bias conditions ranging from sub...

  4. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.

    Science.gov (United States)

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-04-09

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.

  5. [Comfort and noise level in infants with helmet interface].

    Science.gov (United States)

    Medina, A; Alvarez Fernández, P; Rey Galán, C; Álvarez Mendiola, P; Álvarez Blanco, S; Vivanco Allende, A

    2015-10-01

    To evaluate comfort and noise intensity using the COMFORT scale in infants who receive respiratory support with a helmet interface. An observational descriptive study was conducted on all infants (1 to 12 months of age) admitted to a PICU from November 1st 2013 to March 31st 2014 and who received non-invasive ventilation with a helmet interface. Tolerance to the interface was assessed by use of the COMFORT scale. The intensity of the noise to which the infants were exposed was measured with a TES1350A HIBOK 412 sound-level meter. Three measurements were made every day. Twenty seven patients with bronchiolitis (median age: 54 days; range: 10 to 256) were included. Median COMFORT score in the first day was 21 points (14 - 28). An increase in patient comfort was found with a gradual decrease in the scores, with a maximum reduction of 22% from the first hours (score of 22) to the fifth day (score of 18). The minimum sound intensity registered was 42dB, and the maximum was 78dB. Background noise intensity was associated with noise intensity in the helmet. No differences were observed in COMFORT score and noise intensity between ventilator devices. Helmet interface was well tolerated by infants. COMFORT score results are an indicator that infants were comfortable or very comfortable. The measured noise intensity was in the safe range permitted by World Health Organization. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  6. Relationship between lighting and noise levels and productivity of the occupants in automotive assembly industry.

    Science.gov (United States)

    Akbari, Jafar; Dehghan, Habibollah; Azmoon, Hiva; Forouharmajd, Farhad

    2013-01-01

    Work environment affects human productivity and his performance. The aims of this study were to investigate the effects of lighting and noise levels on human productivity in the automotive assembly industry. Subjects were 181 workers from different parts of an automobile assembly industry. Illuminance (Lx) at the height of 30 inches from the surface of work station and noise (dBA) were locally measured. Also human productivity by the Goldsmith and Hersey scale (1980) was measured. Data were analyzed by using SPSS v20 Pearson correlation coefficient. The results showed that the relationship between noise level and human productivity is negative and significant (P productivity (P > 0.05). Based on the results, in assembly tasks, noise has a negative impact on human productivity, and lighting does not affect this. So, in order to increase employee productivity, noise control and reduction to less than the standard values (less than 85 dB) is necessary.

  7. Relationship between Lighting and Noise Levels and Productivity of the Occupants in Automotive Assembly Industry

    Directory of Open Access Journals (Sweden)

    Jafar Akbari

    2013-01-01

    Full Text Available Work environment affects human productivity and his performance. The aims of this study were to investigate the effects of lighting and noise levels on human productivity in the automotive assembly industry. Method. Subjects were 181 workers from different parts of an automobile assembly industry. Illuminance (Lx at the height of 30 inches from the surface of work station and noise (dBA were locally measured. Also human productivity by the Goldsmith and Hersey scale (1980 was measured. Data were analyzed by using SPSS v20 Pearson correlation coefficient. Results. The results showed that the relationship between noise level and human productivity is negative and significant (, , but there was no significant relationship between lighting and human productivity (. Conclusion. Based on the results, in assembly tasks, noise has a negative impact on human productivity, and lighting does not affect this. So, in order to increase employee productivity, noise control and reduction to less than the standard values (less than 85 dB is necessary.

  8. Noise Reduction in Arterial Spin Labeling Based Functional Connectivity Using Nuisance Variables.

    Science.gov (United States)

    Jann, Kay; Smith, Robert X; Rios Piedra, Edgar A; Dapretto, Mirella; Wang, Danny J J

    2016-01-01

    Arterial Spin Labeling (ASL) perfusion image series have recently been utilized for functional connectivity (FC) analysis in healthy volunteers and children with autism spectrum disorders (ASD). Noise reduction by using nuisance variables has been shown to be necessary to minimize potential confounding effects of head motion and physiological signals on BOLD based FC analysis. The purpose of the present study is to systematically evaluate the effectiveness of different noise reduction strategies (NRS) using nuisance variables to improve perfusion based FC analysis in two cohorts of healthy adults using state of the art 3D background-suppressed (BS) GRASE pseudo-continuous ASL (pCASL) and dual-echo 2D-EPI pCASL sequences. Five different NRS were performed in healthy volunteers to compare their performance. We then compared seed-based FC analysis using 3D BS GRASE pCASL in a cohort of 12 children with ASD (3f/9m, age 12.8 ± 1.3 years) and 13 typically developing (TD) children (1f/12m; age 13.9 ± 3 years) in conjunction with NRS. Regression of different combinations of nuisance variables affected FC analysis from a seed in the posterior cingulate cortex (PCC) to other areas of the default mode network (DMN) in both BOLD and pCASL data sets. Consistent with existing literature on BOLD-FC, we observed improved spatial specificity after physiological noise reduction and improved long-range connectivity using head movement related regressors. Furthermore, 3D BS GRASE pCASL shows much higher temporal SNR compared to dual-echo 2D-EPI pCASL and similar effects of noise reduction as those observed for BOLD. Seed-based FC analysis using 3D BS GRASE pCASL in children with ASD and TD children showed that noise reduction including physiological and motion related signals as nuisance variables is crucial for identifying altered long-range connectivity from PCC to frontal brain areas associated with ASD. This is the first study that systematically evaluated the effects of

  9. Optimised Sound Absorbing Trim Panels for the Reduction of Aircraft Cabin Noise

    NARCIS (Netherlands)

    Hannink, M.H.C.; Wijnant, Ysbrand H.; de Boer, Andries; Ivanov, N.I.; Crocker, M.J.

    2004-01-01

    The EU project FACE (Friendly Aircraft Cabin Environment) aims to improve the environmental comfort in aircraft cabins. As part of this project, this paper focuses on the reduction of noise in aircraft cabins. For modern aircraft flying at cruise conditions, this cabin noise is known to be dominated

  10. Noise Reduction Potential of Cellular Metals

    Directory of Open Access Journals (Sweden)

    Björn Hinze

    2012-06-01

    Full Text Available Rising numbers of flights and aircrafts cause increasing aircraft noise, resulting in the development of various approaches to change this trend. One approach is the application of metallic liners in the hot gas path of aero-engines. At temperatures of up to 600 °C only metallic or ceramic structures can be used. Due to fatigue loading and the notch effect of the pores, mechanical properties of porous metals are superior to the ones of ceramic structures. Consequently, cellular metals like metallic foams, sintered metals, or sintered metal felts are most promising materials. However, acoustic absorption depends highly on pore morphology and porosity. Therefore, both parameters must be characterized precisely to analyze the correlation between morphology and noise reduction performance. The objective of this study is to analyze the relationship between pore morphology and acoustic absorption performance. The absorber materials are characterized using image processing based on two dimensional microscopy images. The sound absorption properties are measured using an impedance tube. Finally, the correlation of acoustic behavior, pore morphology, and porosity is outlined.

  11. Simultaneous Reduction in Noise and Cross-Contamination Artifacts for Dual-Energy X-Ray CT

    Directory of Open Access Journals (Sweden)

    Baojun Li

    2013-01-01

    Full Text Available Purpose. Dual-energy CT imaging tends to suffer from much lower signal-to-noise ratio than single-energy CT. In this paper, we propose an improved anticorrelated noise reduction (ACNR method without causing cross-contamination artifacts. Methods. The proposed algorithm diffuses both basis material density images (e.g., water and iodine at the same time using a novel correlated diffusion algorithm. The algorithm has been compared to the original ACNR algorithm in a contrast-enhanced, IRB-approved patient study. Material density accuracy and noise reduction are quantitatively evaluated by the percent density error and the percent noise reduction. Results. Both algorithms have significantly reduced the noises of basis material density images in all cases. The average percent noise reduction is 69.3% and 66.5% with the ACNR algorithm and the proposed algorithm, respectively. However, the ACNR algorithm alters the original material density by an average of 13% (or 2.18 mg/cc with a maximum of 58.7% (or 8.97 mg/cc in this study. This is evident in the water density images as massive cross-contaminations are seen in all five clinical cases. On the contrary, the proposed algorithm only changes the mean density by 2.4% (or 0.69 mg/cc with a maximum of 7.6% (or 1.31 mg/cc. The cross-contamination artifacts are significantly minimized or absent with the proposed algorithm. Conclusion. The proposed algorithm can significantly reduce image noise present in basis material density images from dual-energy CT imaging, with minimized cross-contaminations compared to the ACNR algorithm.

  12. Comparison study of noise reduction algorithms in dual energy chest digital tomosynthesis

    Science.gov (United States)

    Lee, D.; Kim, Y.-S.; Choi, S.; Lee, H.; Choi, S.; Kim, H.-J.

    2018-04-01

    Dual energy chest digital tomosynthesis (CDT) is a recently developed medical technique that takes advantage of both tomosynthesis and dual energy X-ray images. However, quantum noise, which occurs in dual energy X-ray images, strongly interferes with diagnosis in various clinical situations. Therefore, noise reduction is necessary in dual energy CDT. In this study, noise-compensating algorithms, including a simple smoothing of high-energy images (SSH) and anti-correlated noise reduction (ACNR), were evaluated in a CDT system. We used a newly developed prototype CDT system and anthropomorphic chest phantom for experimental studies. The resulting images demonstrated that dual energy CDT can selectively image anatomical structures, such as bone and soft tissue. Among the resulting images, those acquired with ACNR showed the best image quality. Both coefficient of variation and contrast to noise ratio (CNR) were the highest in ACNR among the three different dual energy techniques, and the CNR of bone was significantly improved compared to the reconstructed images acquired at a single energy. This study demonstrated the clinical value of dual energy CDT and quantitatively showed that ACNR is the most suitable among the three developed dual energy techniques, including standard log subtraction, SSH, and ACNR.

  13. Geometric noise reduction for multivariate time series.

    Science.gov (United States)

    Mera, M Eugenia; Morán, Manuel

    2006-03-01

    We propose an algorithm for the reduction of observational noise in chaotic multivariate time series. The algorithm is based on a maximum likelihood criterion, and its goal is to reduce the mean distance of the points of the cleaned time series to the attractor. We give evidence of the convergence of the empirical measure associated with the cleaned time series to the underlying invariant measure, implying the possibility to predict the long run behavior of the true dynamics.

  14. The effects of noise-bandwidth, noise-fringe duration, and temporal signal location on the binaural masking-level difference.

    Science.gov (United States)

    Yasin, Ifat; Henning, G Bruce

    2012-07-01

    The effects of forward and backward noise fringes on binaural signal detectability were investigated. Masked thresholds for a 12-ms, 250-Hz, sinusoidal signal masked by Gaussian noise, centered at 250 Hz, with bandwidths from 3 to 201 Hz, were obtained in N(0)S(0) and N(0)S(π) configurations. The signal was (a) temporally centered in a 12-ms noise burst (no fringe), (b) presented at the start of a 600-ms noise burst (backward fringe), or (c) temporally centered in a 600-ms noise burst (forward-plus-backward fringe). For noise bandwidths between 3 and 75 Hz, detection in N(0)S(0) improved with the addition of a backward fringe, improving further with an additional forward fringe; there was little improvement in N(0)S(π). The binaural masking-level difference (BMLD) increased from 0 to 8 dB with a forward-plus-backward fringe as noise bandwidths increased to 100 Hz, increasing slightly to 10 dB at 201 Hz. This two-stage increase was less pronounced with a backward fringe. With no fringe, the BMLD was about 10-14 dB at all bandwidths. Performance appears to result from the interaction of across-time and across-frequency listening strategies and the possible effects of gain reduction and suppression, which combine in complex ways. Current binaural models are, as yet, unable to account fully for these effects.

  15. [Noise level in a care and teaching hospital institution].

    Science.gov (United States)

    Mendoza-Sánchez, R S; Roque-Sánchez, R H; Moncada-González, B

    1996-01-01

    Noise in the environment is increasing over the years. Disturbances produced by noise are varied, some lead to serious health consequences. Noise level was registered in a teaching hospital. Levels in the wards were between 50 and 59 dB. In the Intensive Care Unit, main hallways and outpatients department levels were higher than 59 dB. Isolated peaks up to 90.0 dB (Pediatrics) were detected. The noise level recommended for a hospital is under 50.0 dB. We found that the principal source of noise came from the medical and nursing staff.

  16. Trends in magnetic resonance imaging. Technical trends in MRI, noise reduction and fast imaging

    International Nuclear Information System (INIS)

    Sugimoto, Hiroshi

    2007-01-01

    At MRI examination, patients suffer the machine noise and long tight lying as well as an oppressive feeling. This paper describes the technological efforts against the former two. The noise is generated from the force (thumb-ward) to vibrate the magnetic field gradient coil according to the left-hand rule. Authors have developed a MRI machine (Pianissimo) where the coil is placed in vacuum and its actual noise level is found reduced from 105 - 112 to 84 dB(A) at 1.5T. Fast imaging to shorten the imaging time is attained by combination of parallel imaging where MR signals are into multiple high frequency receiver coils, and the usual pulse sequence imaging, which results in the increased encoding in a given time. Together with these, MR angiography and diffusion weighted imaging of abdomen for cancer examination are becoming popular as an additional MRI diagnosis, also acceptable to patients. Future progress of MRI machines conceivably accompanies the unavoidable noise increase and possibly significant magnetic effects on human body, and efforts for their reduction will be continued at patients' viewpoint. (T.I.)

  17. Median Filter Noise Reduction of Image and Backpropagation Neural Network Model for Cervical Cancer Classification

    Science.gov (United States)

    Wutsqa, D. U.; Marwah, M.

    2017-06-01

    In this paper, we consider spatial operation median filter to reduce the noise in the cervical images yielded by colposcopy tool. The backpropagation neural network (BPNN) model is applied to the colposcopy images to classify cervical cancer. The classification process requires an image extraction by using a gray level co-occurrence matrix (GLCM) method to obtain image features that are used as inputs of BPNN model. The advantage of noise reduction is evaluated by comparing the performances of BPNN models with and without spatial operation median filter. The experimental result shows that the spatial operation median filter can improve the accuracy of the BPNN model for cervical cancer classification.

  18. On the prediction of impact noise, V: The noise from drop hammers

    Science.gov (United States)

    Richards, E. J.; Carr, I.; Westcott, M.

    1983-06-01

    In earlier papers in this series, the concepts of "acceleration" and "ringing" noise have been studied in relation to impact machines, and values of radiation efficiency have been obtained for the various types of structural components. In the work reported in this paper the predicted and measured noise radiation from a drop hammer, both in full-scale and in {1}/{3}- scale model form, were examined. It is found that overall noise levels ( Leq per event) can be predicted from vibration measurements to within ± 1·5 dB, and to within ±2·5 dB in one-third octave bands. In turn this has permitted noise reduction techniques to be examined by studies of local component vibration levels rather than overall noise, a method which provides considerable enlightenment at the design stage. It is shown that on one particular drop hammer, the noise energy is shared surprisingly uniformly over four or five sources, and that when these have been reduced, the overall noise reduction is severely limited by the "acceleration" noise from the "tup" or "hammer" itself. As this is difficult to eliminate without a basic change in forging technology, it follows that "tup" enclosure or modification of the sharpness of the final "hard" impact are the only means available for any serious noise reduction. Also indicated is the reliability of using model techniques, suitably scaled in frequency and impulse magnitude, in developing machinery with impact characteristics.

  19. Quantum noise and stochastic reduction

    International Nuclear Information System (INIS)

    Brody, Dorje C; Hughston, Lane P

    2006-01-01

    In standard nonrelativistic quantum mechanics the expectation of the energy is a conserved quantity. It is possible to extend the dynamical law associated with the evolution of a quantum state consistently to include a nonlinear stochastic component, while respecting the conservation law. According to the dynamics thus obtained, referred to as the energy-based stochastic Schroedinger equation, an arbitrary initial state collapses spontaneously to one of the energy eigenstates, thus describing the phenomenon of quantum state reduction. In this paper, two such models are investigated: one that achieves state reduction in infinite time and the other in finite time. The properties of the associated energy expectation process and the energy variance process are worked out in detail. By use of a novel application of a nonlinear filtering method, closed-form solutions-algebraic in character and involving no integration-are obtained of both these models. In each case, the solution is expressed in terms of a random variable representing the terminal energy of the system and an independent noise process. With these solutions at hand it is possible to simulate explicitly the dynamics of the quantum states of complicated physical systems

  20. Pediatric CT: implementation of ASIR for substantial radiation dose reduction while maintaining pre-ASIR image noise.

    Science.gov (United States)

    Brady, Samuel L; Moore, Bria M; Yee, Brian S; Kaufman, Robert A

    2014-01-01

    To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current-modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose reduction tool only; no net change to the magnitude

  1. Effect of external classroom noise on schoolchildren's reading and mathematics performance: correlation of noise levels and gender.

    Science.gov (United States)

    Papanikolaou, M; Skenteris, N; Piperakis, S M

    2015-02-01

    The present study investigated the effect of low, medium, and high traffic road noise as well as irrelevant background speech noise on primary school children's reading and mathematical performance. A total of 676 participants (324 boys, 47.9% and 352 girls, 52.1%) of the 4th and 5th elementary classes participated in the project. The participants were enrolled in public primary schools from urban areas and had ages ranging from 9 to 10 years and from. Schools were selected on the basis of increasing levels of exposure to road traffic noise and then classified into three categories (Low noise: 55-66 dB, Medium noise: 67-77 dB, and High noise: 72-80 dB). We measured reading comprehension and mathematical skills in accordance with the national guidelines for elementary education, using a test designed specifically for the purpose of this study. On the one hand, children in low-level noise schools showed statistically significant differences from children in medium- and high-level noise schools in reading performance (plevel noise schools differed significantly from children in high-level noise schools but only in mathematics performance (p=0.001). Girls in general did better in reading score than boys, especially in schools with medium- and high-level noise. Finally the levels of noise and gender were found to be two independent factors.

  2. Study on the Noise Reduction of Vehicle Exhaust NOX Spectra Based on Adaptive EEMD Algorithm

    Directory of Open Access Journals (Sweden)

    Kai Zhang

    2017-01-01

    Full Text Available It becomes a key technology to measure the concentration of the vehicle exhaust components with the transmission spectra. But in the conventional methods for noise reduction and baseline correction, such as wavelet transform, derivative, interpolation, polynomial fitting, and so forth, the basic functions of these algorithms, the number of decomposition layers, and the way to reconstruct the signal have to be adjusted according to the characteristics of different components in the transmission spectra. The parameter settings of the algorithms above are not transcendental, so with them, it is difficult to achieve the best noise reduction effect for the vehicle exhaust spectra which are sharp and drastic in the waveform. In this paper, an adaptive ensemble empirical mode decomposition (EEMD denoising model based on a special normalized index optimization is proposed and used in the spectral noise reduction of vehicle exhaust NOX. It is shown with the experimental results that the method can effectively improve the accuracy of the spectral noise reduction and simplify the denoising process and its operation difficulty.

  3. Low frequency noise reduction using stiff light composite panels

    Institute of Scientific and Technical Information of China (English)

    DENG Yongchang; LIN Weizheng

    2003-01-01

    The experiment presented in this paper is to investigate and analyze the noise reduction at low frequency using stiff light composite panels. Since these composite panels are made of lightweight and stiff materials, this actuation strategy will enable the creation of composite panels for duct noise control without using traditional heavy structural mass. The results suggest that the mass-spring resonance absorption in the case of a comparatively stiff thick panel with a thin flexible plate is more efficient with minimum weight, when subjected to low-frequency (<500 Hz). The efficiency of the panel absorber depends on the mass of the thin flexible plate and the stiffness of the panel.

  4. The effect of hearing aid noise reduction on listening effort in hearing-impaired adults.

    Science.gov (United States)

    Desjardins, Jamie L; Doherty, Karen A

    2014-01-01

    The purpose of the present study was to evaluate the effect of a noise-reduction (NR) algorithm on the listening effort hearing-impaired participants expend on a speech in noise task. Twelve hearing-impaired listeners fitted with behind-the-ear hearing aids with a fast-acting modulation-based NR algorithm participated in this study. A dual-task paradigm was used to measure listening effort with and without the NR enabled in the hearing aid. The primary task was a sentence-in-noise task presented at fixed overall speech performance levels of 76% (moderate listening condition) and 50% (difficult listening condition) correct performance, and the secondary task was a visual-tracking test. Participants also completed measures of working memory (Reading Span test), and processing speed (Digit Symbol Substitution Test) ability. Participants' speech recognition in noise scores did not significantly change with the NR algorithm activated in the hearing aid in either listening condition. The NR algorithm significantly decreased listening effort, but only in the more difficult listening condition. Last, there was a tendency for participants with faster processing speeds to expend less listening effort with the NR algorithm when listening to speech in background noise in the difficult listening condition. The NR algorithm reduced the listening effort adults with hearing loss must expend to understand speech in noise.

  5. Reduction of broadband noise in vehicles by means of active feedforward control

    OpenAIRE

    Misol, Malte; Haase, Thomas; Monner, Hans Peter

    2015-01-01

    Broadband noise in a vehicle’s interior is an important issue because of its negative impact on the passengersʼ comfort and wellbeing. The perception of this broadband noise can increase due to the use of new, less noisy drive concepts and the accompanying loss of masking noise compo-nents. This contribution focuses on the reduction of the transmission of external broadband distur-bances through lightweight panel structures (e.g. a car’s roof liner or an aircraft sidewall panel) by means of a...

  6. Acoustic performance design and optimal allocation of sound package in ship cabin noise reduction

    Directory of Open Access Journals (Sweden)

    YANG Deqing

    2017-08-01

    Full Text Available The sound package in noise reduction design of ship cabins has become the main approach for the future. The sound package is a specially designed acoustic component consisting of damping materials, absorption materials, sound isolation materials and base structural materials which can achieve the prescribed performance of noise reduction. Based on the Statistical Energy Analysis(SEAmethod, quick evaluation and design methods, and the optimal allocation theory of sound packages are investigated. The standard numerical acoustic performance evaluation model, sound package optimization design model and sound package optimal allocation model are presented. A genetic algorithm is applied to solve the presented optimization problems. Design examples demonstrate the validity and efficiency of the proposed models and solutions. The presented theory and methods benefit the standardization and programming of sound package design, and decrease noise reduction costs.

  7. Prediction of Landing Gear Noise Reduction and Comparison to Measurements

    Science.gov (United States)

    Lopes, Leonard V.

    2010-01-01

    Noise continues to be an ongoing problem for existing aircraft in flight and is projected to be a concern for next generation designs. During landing, when the engines are operating at reduced power, the noise from the airframe, of which landing gear noise is an important part, is equal to the engine noise. There are several methods of predicting landing gear noise, but none have been applied to predict the change in noise due to a change in landing gear design. The current effort uses the Landing Gear Model and Acoustic Prediction (LGMAP) code, developed at The Pennsylvania State University to predict the noise from landing gear. These predictions include the influence of noise reduction concepts on the landing gear noise. LGMAP is compared to wind tunnel experiments of a 6.3%-scale Boeing 777 main gear performed in the Quiet Flow Facility (QFF) at NASA Langley. The geometries tested in the QFF include the landing gear with and without a toboggan fairing and the door. It is shown that LGMAP is able to predict the noise directives and spectra from the model-scale test for the baseline configuration as accurately as current gear prediction methods. However, LGMAP is also able to predict the difference in noise caused by the toboggan fairing and by removing the landing gear door. LGMAP is also compared to far-field ground-based flush-mounted microphone measurements from the 2005 Quiet Technology Demonstrator 2 (QTD 2) flight test. These comparisons include a Boeing 777-300ER with and without a toboggan fairing that demonstrate that LGMAP can be applied to full-scale flyover measurements. LGMAP predictions of the noise generated by the nose gear on the main gear measurements are also shown.

  8. Research on noise and vibration reduction at DB to improve the environmental friendliness of railway traffic

    Science.gov (United States)

    Schulte-Werning, B.; Beier, M.; Degen, K. G.; Stiebel, D.

    2006-06-01

    One of the most prominent keywords relating to the environmental friendliness of railway traffic is noise reduction. Thus, the research and development programme "Low Noise Railway" of Deutsche Bahn (DB) is under way to treat the noise of the vehicles and infrastructure. The noise reduction of the trains and the rail/wheel system are being tackled within several projects. The direct noise experienced by railway-lineside residents due to train movements on the track can be reduced by minimising the sound radiation directly at the source. This is the first-choice solution, as it proves to be the most effective countermeasure regarding a cost-benefit relation. The limit values for the noise emission as specified in the technical specification for interoperability are an essential criterion to be confirmed during the procurement process of railway vehicles. A recently developed acoustical quality management scheme establishes systematic noise management to complete the vehicle procurement process in the phases of concept, design, construction and manufacturing. In freight traffic quiet railway wheels for block brake operation will play an important role in the future to meet the goal of a low-noise railway system. A first attempt to realise successfully the low-noise potential of such optimised wheels was performed, even if with mixed results. To show ways of reducing the noise of the cooling ventilation in locomotives, DB is a partner in a development project led by Siemens. A notable 8 dB(A) noise reduction was measured. Concerning bridge noise, a project was started based on an effective and cost-efficient combination of experiments and simulations in order to develop specifications for the construction of generic low-noise bridges.

  9. Impact of Noise and Noise Reduction on Processing Effort: A Pupillometry Study

    DEFF Research Database (Denmark)

    Wendt, Dorothea; Hietkamp, Renskje K; Lunner, Thomas

    2017-01-01

    of noise (intelligibility level) and different NR schemes on effort were evaluated by measuring the pupil dilation of listeners. In 2 different experiments, performance accuracy and peak pupil dilation (PPD) were measured in 24 listeners with hearing impairment while they performed a speech recognition...... task. The listeners were tested at 2 different signal to noise ratios corresponding to either the individual 50% correct (L50) or the 95% correct (L95) performance level in a 4-talker babble condition with and without the use of a NR scheme. In experiment 1, the PPD differed in response to both changes...... in the speech intelligibility level (L50 versus L95) and NR scheme. The PPD increased with decreasing intelligibility, indicating higher processing effort under the L50 condition compared with the L95 condition. Moreover, the PPD decreased when the NR scheme was applied, suggesting that the processing effort...

  10. Noise Levels in Dental Offices and Laboratories in Hamedan, Iran

    Directory of Open Access Journals (Sweden)

    F. Mojarad

    2009-12-01

    Full Text Available Objective: Noise pollution is one of the most important situations requiring a solution by the contemporary world. The National Institute for Occupational Safety and Health has identified noise as one of the ten leading causes of work-related diseases and injuries.Dentists and dental auxiliaries are exposed to different noise levels while working in dental offices or laboratories. The purpose of this study was to measure the noise level made by different dental instruments in dental offices and laboratories.Materials and Methods: Measurement of the noise level was performed in 89 dental offices and nine dental laboratories. The noise levels were determined using a sound level meter; type SL-4011(Lutron ,which was placed at the operator’s ear level in dental offices and laboratories and also at two-meter distance from the technician’s ear in laboratories.Results: The maximum sound level was 85.8 dB in dental offices and 92.0 dB in laboratories.In dental clinics, the highest noise was produced by the ultrasonic-scaler (85.8 dB and the lowest noise (49.7 dB by the high-volume aspirator, whereas in the laboratory,the highest noise was caused during grinding by the stonecutter (92.0 dB and the lowest by the denture-polishing unit (41.0 dB.Conclusion: After close evaluation, we believe that the maximum noise level in dental offices, although often beneath the damaging noise level for the human ear, is very close to the limit of hearing loss (85.0 dB. However, laboratory technicians may be at risk ifthey choose not to wear ear protection (earplugs or earmuffs.

  11. Deep Learning-Based Noise Reduction Approach to Improve Speech Intelligibility for Cochlear Implant Recipients.

    Science.gov (United States)

    Lai, Ying-Hui; Tsao, Yu; Lu, Xugang; Chen, Fei; Su, Yu-Ting; Chen, Kuang-Chao; Chen, Yu-Hsuan; Chen, Li-Ching; Po-Hung Li, Lieber; Lee, Chin-Hui

    2018-01-20

    We investigate the clinical effectiveness of a novel deep learning-based noise reduction (NR) approach under noisy conditions with challenging noise types at low signal to noise ratio (SNR) levels for Mandarin-speaking cochlear implant (CI) recipients. The deep learning-based NR approach used in this study consists of two modules: noise classifier (NC) and deep denoising autoencoder (DDAE), thus termed (NC + DDAE). In a series of comprehensive experiments, we conduct qualitative and quantitative analyses on the NC module and the overall NC + DDAE approach. Moreover, we evaluate the speech recognition performance of the NC + DDAE NR and classical single-microphone NR approaches for Mandarin-speaking CI recipients under different noisy conditions. The testing set contains Mandarin sentences corrupted by two types of maskers, two-talker babble noise, and a construction jackhammer noise, at 0 and 5 dB SNR levels. Two conventional NR techniques and the proposed deep learning-based approach are used to process the noisy utterances. We qualitatively compare the NR approaches by the amplitude envelope and spectrogram plots of the processed utterances. Quantitative objective measures include (1) normalized covariance measure to test the intelligibility of the utterances processed by each of the NR approaches; and (2) speech recognition tests conducted by nine Mandarin-speaking CI recipients. These nine CI recipients use their own clinical speech processors during testing. The experimental results of objective evaluation and listening test indicate that under challenging listening conditions, the proposed NC + DDAE NR approach yields higher intelligibility scores than the two compared classical NR techniques, under both matched and mismatched training-testing conditions. When compared to the two well-known conventional NR techniques under challenging listening condition, the proposed NC + DDAE NR approach has superior noise suppression capabilities and gives less distortion

  12. New solution for transport and industrial noise protection through reflective noise barriers

    Directory of Open Access Journals (Sweden)

    Kralov Ivan

    2017-01-01

    Full Text Available A new solution for protection of transportation and industrial noise through reflective noise barriers is proposed and investigated in this study. The new solution combines the advantages of the known barriers and has its own advantages in addition. The preliminary results show a very good level of noise reduction for this type of barriers.

  13. Wing Leading Edge Concepts for Noise Reduction

    Science.gov (United States)

    Shmilovich, Arvin; Yadlin, Yoram; Pitera, David M.

    2010-01-01

    This study focuses on the development of wing leading edge concepts for noise reduction during high-lift operations, without compromising landing stall speeds, stall characteristics or cruise performance. High-lift geometries, which can be obtained by conventional mechanical systems or morphing structures have been considered. A systematic aerodynamic analysis procedure was used to arrive at several promising configurations. The aerodynamic design of new wing leading edge shapes is obtained from a robust Computational Fluid Dynamics procedure. Acoustic benefits are qualitatively established through the evaluation of the computed flow fields.

  14. Enhanced ground bounce noise reduction in a low-leakage CMOS multiplier

    Science.gov (United States)

    Verma, Bipin Kumar; Akashe, Shyam; Sharma, Sanjay

    2015-09-01

    In this paper, various parameters are used to reduce leakage power, leakage current and noise margin of circuits to enhance their performance. A multiplier is proposed with low-leakage current and low ground bounce noise for the microprocessor, digital signal processors (DSP) and graphics engines. The ground bounce noise problem appears when a conventional power-gating circuit transits from sleep-to-active mode. This paper discusses a reduction in leakage current in the stacking power-gating technique by three modes - sleep, active and sleep-to-active. The simulation results are performed on a 4 × 4 carry-save multiplier for leakage current, active power, leakage power and ground bounce noise, and comparison made for different nanoscales. Ground bounce noise is limited to 90%. The leakage current of the circuit is decimated up to 80% and the active power is reduced to 31%. We performed simulations using cadence virtuoso 180 and 45 nm at room temperature at various supply voltages.

  15. Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography.

    Science.gov (United States)

    Waugh, William; Allen, John; Wightman, James; Sims, Andrew J; Beale, Thomas A W

    2018-01-01

    Physiological signals can often become contaminated by noise from a variety of origins. In this paper, an algorithm is described for the reduction of sporadic noise from a continuous periodic signal. The design can be used where a sample of a periodic signal is required, for example, when an average pulse is needed for pulse wave analysis and characterization. The algorithm is based on cluster analysis for selecting similar repetitions or pulses from a periodic single. This method selects individual pulses without noise, returns a clean pulse signal, and terminates when a sufficiently clean and representative signal is received. The algorithm is designed to be sufficiently compact to be implemented on a microcontroller embedded within a medical device. It has been validated through the removal of noise from an exemplar photoplethysmography (PPG) signal, showing increasing benefit as the noise contamination of the signal increases. The algorithm design is generalised to be applicable for a wide range of physiological (physical) signals.

  16. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gunja, Ateka; Pandey, Yagya [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Xie, Hui [Division of Epidemiology and Biostatistics, University of Illinois at Chicago, Chicago, IL (United States); Faculty of Health Sciences, Simon Fraser University, Burnaby, BC (Canada); Wolska, Beata M. [Department of Physiology and Biophysics, Center for Cardiovascular Research, University of Illinois at Chicago, Chicago, IL (United States); Shroff, Adhir R.; Ardati, Amer K. [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Vidovich, Mladen I., E-mail: miv@uic.edu [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States)

    2017-04-15

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm{sup 2}). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm{sup 2} ± 74.0 vs. 41.9 mGy cm{sup 2} ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image-noise

  17. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    International Nuclear Information System (INIS)

    Gunja, Ateka; Pandey, Yagya; Xie, Hui; Wolska, Beata M.; Shroff, Adhir R.; Ardati, Amer K.; Vidovich, Mladen I.

    2017-01-01

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm"2). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm"2 ± 74.0 vs. 41.9 mGy cm"2 ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image-noise compared to

  18. Usefulness of acoustic noise reduction in brain MRI using Quiet-T{sub 2}-

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Se Jy [Dept. of Medical science Graduate school, Chonnam National University, Gwangju (Korea, Republic of); Kim, Young Keun [Dept. of Radiotechnology, Gwangju Health university, Gwangju (Korea, Republic of)

    2016-03-15

    Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-T{sub 2} and T{sub 2} sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-T{sub 2} and T{sub 2} was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-T{sub 2}, T{sub 2} and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-T{sub 2} and T{sub 2}. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by 15dBA and 10dBA on T2 and Q-T2 test. Also, the average value of heartbeat rate was lower in Q-T2 for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-T{sub 2}. According to the qualitative analysis, the overall quality image of 59 case T{sub 2} and Q-T{sub 2} was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-T{sub 2} is a promising technique for acoustic noise reduction and improved patient comfort.

  19. A study for reduction of radiation pressure noise in gravitational wave detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sakata, S; Sugamoto, A [Graduate School of Humanities and Sciences, Ochanomizu University, 2-1-1 Otsuka, Bunkyo-ku, Tokyo, 112-8610 (Japan); Leonhardt, V; Kawamura, S; Sato, S; Yamazaki, T; Fukushima, M [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Numata, K [NASA Goddard Space Flight Center, CRESST, Code 663, Greenbelt, MD 20771 (United States); Miyakawa, O [LIGO Laboratory 18-34, California Institute of Technology, Pasadena, CA 91125 (United States); Nishizawa, A [Graduate School of Human and Environmental Studies, Kyoto University, Kyoto 606-8501 (Japan); Furusawa, A [Department of Applied Physics, School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)], E-mail: shihori.sakata@nao.ac.jp

    2008-07-15

    We describe an experimental conceptual design for observation and reduction of radiation pressure noise. The radiation pressure noise is increased in a high finesse cavity with a small mass mirror. In our experiment a Fabry-Perot Michelson interferometer with a homodyne detection scheme will be built with Fabry-Perot cavities of finesse of 10000 containing suspended mirrors of 23 mg. To observe the radiation pressure noise, the goal sensitivity is set to 1x10{sup -17} [m/ {radical}Hz] at 1 kHz. Then the radiation pressure noise is reduced by adjusting the homodyne phase. To achieve the sensitivity, the other noise sources such as thermal noises, seismic noise and laser frequency noise should be suppressed below 1x10{sup -18} [m/{radical} Hz] at 1kHz. The whole interferometer is suspended as a double pendulum on double-layer stacks. As a preliminary setup, a Fabry-Perot cavity of finesse of 800 with a suspended mirror of 100 mg was locked. The current best sensitivity is 1x10{sup -15} [m/ {radical}Hz] at 1 kHz.

  20. Single-photoelectron noise reduction in scintillation detectors

    International Nuclear Information System (INIS)

    Marvin, T.P.

    1995-10-01

    The 1994--95 search at SLAC for mulicharged particles used four 21 x 21 x 130-cm 3 Bicron 408 scintillation counters to detect a signal at the single-photoelectron level. The competing noise requiring minimization was due to a combination of PM tube (8-inch Thorne EMI 9353KA) afterpulsing and ambient radiation-induced scintillator luminescence. A very slow decay (> 30 μs) component was observed and received particular attention. Efforts to reduce the SPE noise included photomultiplier tube base modifications, detector shielding and cooling, signal amplification, and veto procedures

  1. Broadband transmission noise reduction of smart panels featuring piezoelectric shunt circuits and sound-absorbing material.

    Science.gov (United States)

    Kim, Jaehwan; Lee, Joong-Kuen

    2002-09-01

    The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. A piezoelectric smart panel is basically a plate structure on which piezoelectric patches with electrical shunt circuits are mounted and sound-absorbing material is bonded on the surface of the structure. Sound-absorbing material can absorb the sound transmitted at the midfrequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonance frequencies, piezoelectric damping using the measured electrical impedance model is adopted. A resonant shunt circuit for piezoelectric shunt damping is composed of resistor and inductor in series, and they are determined by maximizing the dissipated energy through the circuit. The transmitted noise-reduction performance of smart panels is tested in an acoustic tunnel. The tunnel is a square cross-sectional tube and a loudspeaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in the midfrequency region is observed except for the fundamental resonance frequency of the plate. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive absorbing material and piezoelectric shunt damping is a promising technology for noise reduction over a broadband of frequencies.

  2. Identification and reduction of vibration and noise of a glass tempering system

    International Nuclear Information System (INIS)

    Ashhab, M S

    2015-01-01

    The vibration and noise of a glass tempering machine at a factory are studied. Experiments were conducted to identify the sources of vibration and noise. It was found that main sources for vibration and noise are two air barrels, the air pipes from the fans to the glass tempering machine and the fans location. Solutions were suggested to reduce vibration and noise from these three main sources. One of the solutions that were implemented is placing rubber dampers beneath the air barrels and pipes which almost cancelled the horizontal vibrations in the building structure and reduced the vertical vibrations to a low value most likely coming from noise. There are two types of noise, namely, radiation noise from the fans through the fans room walls and transmitted noise through the pipes caused by turbulence. A glass wool noise insulating layer was installed on the wall between the fans room and factory to reduce radiation noise through this wall. Part of the air pipe system in the factory is made of a light material which produced the highest levels of noise above 110 dBA. These air pipes were wrapped by glass wool rolls and the noise level near them was reduced to below 100 dBA which comes from other machine parts. In addition, noise levels were reduced between 2 and 15 dBA at different points in the factory. (paper)

  3. RANS Analyses of Turbofan Nozzles with Internal Wedge Deflectors for Noise Reduction

    Science.gov (United States)

    DeBonis, James R.

    2009-01-01

    Computational fluid dynamics (CFD) was used to evaluate the flow field and thrust performance of a promising concept for reducing the noise at take-off of dual-stream turbofan nozzles. The concept, offset stream technology, reduces the jet noise observed on the ground by diverting (offsetting) a portion of the fan flow below the core flow, thickening and lengthening this layer between the high-velocity core flow and the ground observers. In this study a wedge placed in the internal fan stream is used as the diverter. Wind, a Reynolds averaged Navier-Stokes (RANS) code, was used to analyze the flow field of the exhaust plume and to calculate nozzle performance. Results showed that the wedge diverts all of the fan flow to the lower side of the nozzle, and the turbulent kinetic energy on the observer side of the nozzle is reduced. This reduction in turbulent kinetic energy should correspond to a reduction in noise. However, because all of the fan flow is diverted, the upper portion of the core flow is exposed to the freestream, and the turbulent kinetic energy on the upper side of the nozzle is increased, creating an unintended noise source. The blockage due to the wedge reduces the fan mass flow proportional to its blockage, and the overall thrust is consequently reduced. The CFD predictions are in very good agreement with experimental flow field data, demonstrating that RANS CFD can accurately predict the velocity and turbulent kinetic energy fields. While this initial design of a large scale wedge nozzle did not meet noise reduction or thrust goals, this study identified areas for improvement and demonstrated that RANS CFD can be used to improve the concept.

  4. Combat aircraft noise

    Science.gov (United States)

    Sgarbozza, M.; Depitre, A.

    1992-04-01

    A discussion of the characteristics and the noise levels of combat aircraft and of a transport aircraft in taking off and landing are presented. Some methods of noise reduction are discussed, including the following: operational anti-noise procedures; and concepts of future engines (silent post-combustion and variable cycle). Some measurement results concerning the noise generated in flight at great speeds and low altitude will also be examined. Finally, the protection of the environment of French air bases against noise will be described and the possibilities of regulation examined.

  5. An Assessment of Psychological Noise Reduction by Landscape Plants

    Directory of Open Access Journals (Sweden)

    Fan Yang

    2011-04-01

    Full Text Available The emphasis in the term ‘Green Transportation’ is on the word ‘green’. Green transportation focuses on the construction of a slow transport system with a visually pleasing, easy and secure trip environment composed of urban parks, green roadside spaces and some other space that is full of landscape plants. This trip environment encourages residents to make trip choices that reduce fuel consumption and pollution and is one of the most important ways of popularizing green transportation. To study the psychological benefits provided by urban parks and other landscape environments, we combined a subjective approach (a questionnaire with an objective quantitative approach (emotional tests using an electroencephalogram; EEG. Using a questionnaire survey, we found that 90% of the subjects believed that landscape plants contribute to noise reduction and that 55% overrated the plants’ actual ability to attenuate noise. Two videos (showing a traffic scene and a plant scene were shown to 40 participants on video glasses. We detected and recorded EEG values with a portable electroencephalograph, and a comparison between the results of the two groups revealed that there was a highly significant asymmetry between the EEG activity of the vegetation scene and traffic scene groups. The results suggest that the emotions aroused by noise and visual stimuli are manifested in the synchronization of beta frequency band and the desynchronization of alpha frequency band, indicating that landscape plants can moderate or buffer the effects of noise. These findings indicate that landscape plants provide excess noise attenuating effects through subjects’ emotional processing, which we term ‘psychological noise reduction’.

  6. Self-reported sleep disturbances due to railway noise: exposure-response relationships for nighttime equivalent and maximum noise levels.

    Science.gov (United States)

    Aasvang, Gunn Marit; Moum, Torbjorn; Engdahl, Bo

    2008-07-01

    The objective of the present survey was to study self-reported sleep disturbances due to railway noise with respect to nighttime equivalent noise level (L(p,A,eq,night)) and maximum noise level (L(p,A,max)). A sample of 1349 people in and around Oslo in Norway exposed to railway noise was studied in a cross-sectional survey to obtain data on sleep disturbances, sleep problems due to noise, and personal characteristics including noise sensitivity. Individual noise exposure levels were determined outside of the bedroom facade, the most-exposed facade, and inside the respondents' bedrooms. The exposure-response relationships were analyzed by using logistic regression models, controlling for possible modifying factors including the number of noise events (train pass-by frequency). L(p,A,eq,night) and L(p,A,max) were significantly correlated, and the proportion of reported noise-induced sleep problems increased as both L(p,A,eq,night) and L(p,A,max) increased. Noise sensitivity, type of bedroom window, and pass-by frequency were significant factors affecting noise-induced sleep disturbances, in addition to the noise exposure level. Because about half of the study population did not use a bedroom at the most-exposed side of the house, the exposure-response curve obtained by using noise levels for the most-exposed facade underestimated noise-induced sleep disturbance for those who actually have their bedroom at the most-exposed facade.

  7. Acoustic-noise-optimized diffusion-weighted imaging.

    Science.gov (United States)

    Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M

    2015-12-01

    This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.

  8. Effects of cavity resonances on sound transmission into a thin cylindrical shell. [noise reduction in aircraft fuselage

    Science.gov (United States)

    Koval, L. R.

    1978-01-01

    In the context of the transmission of airborne noise into an aircraft fuselage, a mathematical model is presented for the effects of internal cavity resonances on sound transmission into a thin cylindrical shell. The 'noise reduction' of the cylinder is defined and computed, with and without including the effects of internal cavity resonances. As would be expected, the noise reduction in the absence of cavity resonances follows the same qualitative pattern as does transmission loss. Numerical results show that cavity resonances lead to wide fluctuations and a general decrease of noise reduction, especially at cavity resonances. Modest internal absorption is shown to greatly reduce the effect of cavity resonances. The effects of external airflow, internal cabin pressurization, and different acoustical properties inside and outside the cylinder are also included and briefly examined.

  9. Noise reduction and image enhancement using a hardware implementation of artificial neural networks

    Science.gov (United States)

    David, Robert; Williams, Erin; de Tremiolles, Ghislain; Tannhof, Pascal

    1999-03-01

    In this paper, we present a neural based solution developed for noise reduction and image enhancement using the ZISC, an IBM hardware processor which implements the Restricted Coulomb Energy algorithm and the K-Nearest Neighbor algorithm. Artificial neural networks present the advantages of processing time reduction in comparison with classical models, adaptability, and the weighted property of pattern learning. The goal of the developed application is image enhancement in order to restore old movies (noise reduction, focus correction, etc.), to improve digital television images, or to treat images which require adaptive processing (medical images, spatial images, special effects, etc.). Image results show a quantitative improvement over the noisy image as well as the efficiency of this system. Further enhancements are being examined to improve the output of the system.

  10. Random resampling masks: a non-Bayesian one-shot strategy for noise reduction in digital holography.

    Science.gov (United States)

    Bianco, V; Paturzo, M; Memmolo, P; Finizio, A; Ferraro, P; Javidi, B

    2013-03-01

    Holographic imaging may become severely degraded by a mixture of speckle and incoherent additive noise. Bayesian approaches reduce the incoherent noise, but prior information is needed on the noise statistics. With no prior knowledge, one-shot reduction of noise is a highly desirable goal, as the recording process is simplified and made faster. Indeed, neither multiple acquisitions nor a complex setup are needed. So far, this result has been achieved at the cost of a deterministic resolution loss. Here we propose a fast non-Bayesian denoising method that avoids this trade-off by means of a numerical synthesis of a moving diffuser. In this way, only one single hologram is required as multiple uncorrelated reconstructions are provided by random complementary resampling masks. Experiments show a significant incoherent noise reduction, close to the theoretical improvement bound, resulting in image-contrast improvement. At the same time, we preserve the resolution of the unprocessed image.

  11. A quantitative comparison of noise reduction across five commercial (hybrid and model-based) iterative reconstruction techniques: an anthropomorphic phantom study.

    Science.gov (United States)

    Patino, Manuel; Fuentes, Jorge M; Hayano, Koichi; Kambadakone, Avinash R; Uyeda, Jennifer W; Sahani, Dushyant V

    2015-02-01

    OBJECTIVE. The objective of our study was to compare the performance of three hybrid iterative reconstruction techniques (IRTs) (ASiR, iDose4, SAFIRE) and their respective strengths for image noise reduction on low-dose CT examinations using filtered back projection (FBP) as the standard reference. Also, we compared the performance of these three hybrid IRTs with two model-based IRTs (Veo and IMR) for image noise reduction on low-dose examinations. MATERIALS AND METHODS. An anthropomorphic abdomen phantom was scanned at 100 and 120 kVp and different tube current-exposure time products (25-100 mAs) on three CT systems (for ASiR and Veo, Discovery CT750 HD; for iDose4 and IMR, Brilliance iCT; and for SAFIRE, Somatom Definition Flash). Images were reconstructed using FBP and using IRTs at various strengths. Nine noise measurements (mean ROI size, 423 mm(2)) on extracolonic fat for the different strengths of IRTs were recorded and compared with FBP using ANOVA. Radiation dose, which was measured as the volume CT dose index and dose-length product, was also compared. RESULTS. There were no significant differences in radiation dose and image noise among the scanners when FBP was used (p > 0.05). Gradual image noise reduction was observed with each increasing increment of hybrid IRT strength, with a maximum noise suppression of approximately 50% (48.2-53.9%). Similar noise reduction was achieved on the scanners by applying specific hybrid IRT strengths. Maximum noise reduction was higher on model-based IRTs (68.3-81.1%) than hybrid IRTs (48.2-53.9%) (p < 0.05). CONCLUSION. When constant scanning parameters are used, radiation dose and image noise on FBP are similar for CT scanners made by different manufacturers. Significant image noise reduction is achieved on low-dose CT examinations rendered with IRTs. The image noise on various scanners can be matched by applying specific hybrid IRT strengths. Model-based IRTs attain substantially higher noise reduction than hybrid

  12. Effects of acoustic treatment on the interior noise levels of a twin-engine propeller aircraft - Experimental flight results and theoretical predictions

    Science.gov (United States)

    Beyer, T. B.; Powell, C. A.; Daniels, E. F.; Pope, L. D.

    1984-01-01

    In-flight noise level measurements were made within two cabin configurations of a general aviation business aircraft. The Fairchild Merlin IVC twin-engine aircraft was tested with bare walls and fiberglass insulation and in an executive trim configuration. Narrow-band and octave format data were subjected to analyses which permitted identification of the blade passage harmonics (BPH). Cabin noise level reductions (insertion losses) due to added insulation varied with position in the cabin, the BPH number, cabin pressure, and engine torque. The measurements were closely predicted using the propeller aircraft interior noise (PAIN) mode.

  13. Noise Reduction of Steel Cord Conveyor Belt Defect Electromagnetic Signal by Combined Use of Improved Wavelet and EMD

    Directory of Open Access Journals (Sweden)

    Hong-Wei Ma

    2016-09-01

    Full Text Available In order to reduce the noise of a defect electromagnetic signal of the steel cord conveyor belt used in coal mines, a new signal noise reduction method by combined use of the improved threshold wavelet and Empirical Mode Decomposition (EMD is proposed. Firstly, the denoising method based on the improved threshold wavelet is applied to reduce the noise of a defect electromagnetic signal obtained by an electromagnetic testing system. Then, the EMD is used to decompose the denoised signal and then the effective Intrinsic Mode Function (IMF is extracted by the dominant eigenvalue strategy. Finally, the signal reconstruction is carried out by utilizing the obtained IMF. In order to verify the proposed noise reduction method, the experiments are carried out in two cases including the defective joint and steel wire rope break. The experimental results show that the proposed method in this paper obtains the higher Signal to Noise Ratio (SNR for the defect electromagnetic signal noise reduction of steel cord conveyor belts.

  14. Noise Reduction for Nonlinear Nonstationary Time Series Data using Averaging Intrinsic Mode Function

    Directory of Open Access Journals (Sweden)

    Christofer Toumazou

    2013-07-01

    Full Text Available A novel noise filtering algorithm based on averaging Intrinsic Mode Function (aIMF, which is a derivation of Empirical Mode Decomposition (EMD, is proposed to remove white-Gaussian noise of foreign currency exchange rates that are nonlinear nonstationary times series signals. Noise patterns with different amplitudes and frequencies were randomly mixed into the five exchange rates. A number of filters, namely; Extended Kalman Filter (EKF, Wavelet Transform (WT, Particle Filter (PF and the averaging Intrinsic Mode Function (aIMF algorithm were used to compare filtering and smoothing performance. The aIMF algorithm demonstrated high noise reduction among the performance of these filters.

  15. Ensemble empirical mode decomposition based fluorescence spectral noise reduction for low concentration PAHs

    Science.gov (United States)

    Wang, Shu-tao; Yang, Xue-ying; Kong, De-ming; Wang, Yu-tian

    2017-11-01

    A new noise reduction method based on ensemble empirical mode decomposition (EEMD) is proposed to improve the detection effect for fluorescence spectra. Polycyclic aromatic hydrocarbons (PAHs) pollutants, as a kind of important current environmental pollution source, are highly oncogenic. Using the fluorescence spectroscopy method, the PAHs pollutants can be detected. However, instrument will produce noise in the experiment. Weak fluorescent signals can be affected by noise, so we propose a way to denoise and improve the detection effect. Firstly, we use fluorescence spectrometer to detect PAHs to obtain fluorescence spectra. Subsequently, noises are reduced by EEMD algorithm. Finally, the experiment results show the proposed method is feasible.

  16. Noise level in neonatal incubators: A comparative study of three models.

    Science.gov (United States)

    Fernández Zacarías, F; Beira Jiménez, J L; Bustillo Velázquez-Gaztelu, P J; Hernández Molina, R; Lubián López, Simón

    2018-04-01

    Preterm infants usually have to spend a long time in an incubator, excessive noise in which can have adverse physiological and psychological effects on neonates. In fact, incubator noise levels typically range from 45 to 70 dB but differences in this respect depend largely on the noise measuring method used. The primary aim of this work was to assess the extent to which noise in an incubator comes from its own fan and how efficiently the incubator can isolate external noise. Three different incubator models were characterized for acoustic performance by measuring their internal noise levels in an anechoic chamber, and also for noise isolation efficiency by using a pink noise source in combination with an internal and an external microphone that were connected to an SVAN958 noise analyzer. The incubators studied produced continuous equivalent noise levels of 53.5-58 dB and reduced external noise by 5.2-10.4 dB. A preterm infant in an incubator is exposed to noise levels clearly exceeding international recommendations even though such levels usually comply with the limit set in the standard IEC60601-2-19: 2009 (60 dBA) under normal conditions of use. Copyright © 2018. Published by Elsevier B.V.

  17. Application of Circulation Control Technology to Airframe Noise Reduction

    Science.gov (United States)

    Ahuja, K. K.; Sankar, L. N.; Englar, R. J.; Munro, Scott E.; Li, Yi; Gaeta, R. J.

    2003-01-01

    This report is a summary of the work performed by Georgia Tech Research Institute (GTRI) under NASA Langley Grant NAG-1-2146, which was awarded as a part of NASA's Breakthrough Innovative Technologies (BIT) initiative. This was a three-year program, with a one-year no-cost extension. Each year's study has been an integrated effort consisting of computational fluid dynamics, experimental aerodynamics, and detailed noise and flow measurements. Year I effort examined the feasibility of reducing airframe noise by replacing the conventional wing systems with a Circulation Control Wing (CCW), where steady blowing was used through the trailing edge of the wing over a Coanda surface. It was shown that the wing lift increases with CCW blowing and indeed for the same lift, a CCW wing was shown to produce less noise. Year 2 effort dealt with a similar study on the role of pulsed blowing on airframe noise. The main objective of this portion of the study was to assess whether pulse blowing from the trailing edge of a CCW resulted in more, less, or the same amount of radiated noise to the farfield. Results show that a reduction in farfield noise of up to 5 dB is measured when pulse flow is compared with steady flow for an equivalent lift configuration. This reduction is in the spectral region associated with the trailing edge jet noise. This result is due to the unique advantage that pulsed flow has over steady flow. For a range of frequencies, more lift is experienced with the same mass flow as the steady case. Thus, for an equivalent lift and slot height, the pulsed system can operate at lower jet velocities, and hence lower jet noise. The computational analysis showed that for a given time-averaged mass flow rate, pulsed jets give a higher value of C(sub l) and a higher L/D than equivalent steady jets. This benefit is attributable to higher instantaneous jet velocities, and higher instantaneous C(sub mu) values for the pulsed jet. Pulsed jet benefits increase at higher

  18. Evaluation of a Noise Reduction Procedure for Chest Radiography

    Science.gov (United States)

    Fukui, Ryohei; Ishii, Rie; Kodani, Kazuhiko; Kanasaki, Yoshiko; Suyama, Hisashi; Watanabe, Masanari; Nakamoto, Masaki; Fukuoka, Yasushi

    2013-01-01

    Background The aim of this study was to evaluate the usefulness of noise reduction procedure (NRP), a function in the new image processing for chest radiography. Methods A CXDI-50G Portable Digital Radiography System (Canon) was used for X-ray detection. Image noise was analyzed with a noise power spectrum (NPS) and a burger phantom was used for evaluation of density resolution. The usefulness of NRP was evaluated by chest phantom images and clinical chest radiography. We employed the Bureau of Radiological Health Method for scoring chest images while carrying out our observations. Results NPS through the use of NRP was improved compared with conventional image processing (CIP). The results in image quality showed high-density resolution through the use of NRP, so that chest radiography examination can be performed with a low dose of radiation. Scores were significantly higher than for CIP. Conclusion In this study, use of NRP led to a high evaluation in these so we are able to confirm the usefulness of NRP for clinical chest radiography. PMID:24574577

  19. Low Delay Noise Reduction and Dereverberation for Hearing Aids

    Directory of Open Access Journals (Sweden)

    Heinrich W. Löllmann

    2009-01-01

    Full Text Available A new system for single-channel speech enhancement is proposed which achieves a joint suppression of late reverberant speech and background noise with a low signal delay and low computational complexity. It is based on a generalized spectral subtraction rule which depends on the variances of the late reverberant speech and background noise. The calculation of the spectral variances of the late reverberant speech requires an estimate of the reverberation time (RT which is accomplished by a maximum likelihood (ML approach. The enhancement with this blind RT estimation achieves almost the same speech quality as by using the actual RT. In comparison to commonly used post-filters in hearing aids which only perform a noise reduction, a significantly better objective and subjective speech quality is achieved. The proposed system performs time-domain filtering with coefficients adapted in the non-uniform (Bark-scaled frequency-domain. This allows to achieve a high speech quality with low signal delay which is important for speech enhancement in hearing aids or related applications such as hands-free communication systems.

  20. Are the noise levels acceptable in a built environment like Hong Kong?

    Science.gov (United States)

    To, Wai Ming; Mak, Cheuk Ming; Chung, Wai Leung

    2015-01-01

    Governments all over the world have enacted environmental noise directives and noise control ordinances/acts to protect tranquility in residential areas. However, there is a lack of literature on the evaluation of whether the Acceptable Noise Levels (ANLs) stipulated in the directive/ordinance/act are actually achievable. The study aimed at measuring outdoor environmental noise levels in Hong Kong and identifying whether the measured noise levels are lower than the stipulated ANLs at 20 categories of residential areas. Data were gathered from a territory-wide noise survey. Outdoor noise measurements were conducted at 203 residential premises in urban areas, low-density residential areas, rural areas, and other areas. In total, 366 daytime hourly Leq outdoor noise levels, 362 nighttime hourly Leq outdoor noise levels, and 20 sets of daily, that is, 24 Leq,1-h outdoor noise levels were recorded. The mean daytime Leq,1-h values ranged 54.4-70.8 dBA, while the mean nighttime Leq,1-h values ranged 52.6-67.9 dBA. When the measured noise levels were compared with the stipulated ANLs, only three out of the 20 categories of areas had outdoor noise levels below ANLs during daytime. All other areas (and all areas during nighttime) were found to have outdoor noise levels at or above ANLs. PMID:26572703

  1. Single-Channel Noise Reduction using Unified Joint Diagonalization and Optimal Filtering

    DEFF Research Database (Denmark)

    Nørholm, Sidsel Marie; Benesty, Jacob; Jensen, Jesper Rindom

    2014-01-01

    consider two cases, where, respectively, no distortion and distortion are incurred on the desired signal. The former can be achieved when the covariance matrix of the desired signal is rank deficient, which is the case, for example, for voiced speech. In the latter case, the covariance matrix......In this paper, the important problem of single-channel noise reduction is treated from a new perspective. The problem is posed as a filtering problem based on joint diagonalization of the covariance matrices of the desired and noise signals. More specifically, the eigenvectors from the joint...

  2. Electrocardiogram (ECG Signal Modeling and Noise Reduction Using Hopfield Neural Networks

    Directory of Open Access Journals (Sweden)

    F. Bagheri

    2013-02-01

    Full Text Available The Electrocardiogram (ECG signal is one of the diagnosing approaches to detect heart disease. In this study the Hopfield Neural Network (HNN is applied and proposed for ECG signal modeling and noise reduction. The Hopfield Neural Network (HNN is a recurrent neural network that stores the information in a dynamic stable pattern. This algorithm retrieves a pattern stored in memory in response to the presentation of an incomplete or noisy version of that pattern. Computer simulation results show that this method can successfully model the ECG signal and remove high-frequency noise.

  3. Characteristics of noise-canceling headphones to reduce the hearing hazard for MP3 users.

    Science.gov (United States)

    Liang, Maojin; Zhao, Fei; French, David; Zheng, Yiqing

    2012-06-01

    Three pairs of headphones [standard iPod ear buds and two noise-canceling headphones (NCHs)] were chosen to investigate frequency characteristics of noise reduction, together with their attenuation effects on preferred listening levels (PLLs) in the presence of various types of background noise. Twenty-six subjects with normal hearing chose their PLLs in quiet, street noise, and subway noise using the three headphones and with the noise-canceling system on/off. Both sets of NCHs reduced noise levels at mid- and high-frequencies. Further noise reductions occurred in low frequencies with the noise canceling system switched on. In street noise, both NCHs had similar noise reduction effects. In subway noise, better noise reduction effects were found in the expensive NCH and with noise-canceling on. A two way repeated measures analysis of variance showed that both listening conditions and headphone styles were significant influencing factors on the PLLs. Subjects tended to increase their PLLs as the background noise level increased. Compared with ear buds, PLLs obtained from NCHs-on in the presence of background noise were reduced up to 4 dB. Therefore, proper selection and use of NCHs appears beneficial in reducing the risk of hearing damage caused by high music listening levels in the presence of background noise.

  4. A critical review of hearing-aid single-microphone noise-reduction studies in adults and children.

    Science.gov (United States)

    Chong, Foong Yen; Jenstad, Lorienne M

    2017-10-26

    Single-microphone noise reduction (SMNR) is implemented in hearing aids to suppress background noise. The purpose of this article was to provide a critical review of peer-reviewed studies in adults and children with sensorineural hearing loss who were fitted with hearing aids incorporating SMNR. Articles published between 2000 and 2016 were searched in PUBMED and EBSCO databases. Thirty-two articles were included in the final review. Most studies with adult participants showed that SMNR has no effect on speech intelligibility. Positive results were reported for acceptance of background noise, preference, and listening effort. Studies of school-aged children were consistent with the findings of adult studies. No study with infants or young children of under 5 years old was found. Recent studies on noise-reduction systems not yet available in wearable hearing aids have documented benefits of noise reduction on memory for speech processing for older adults. This evidence supports the use of SMNR for adults and school-aged children when the aim is to improve listening comfort or reduce listening effort. Future research should test SMNR with infants and children who are younger than 5 years of age. Further development, testing, and clinical trials should be carried out on algorithms not yet available in wearable hearing aids. Testing higher cognitive level for speech processing and learning of novel sounds or words could show benefits of advanced signal processing features. These approaches should be expanded to other populations such as children and younger adults. Implications for rehabilitation The review provides a quick reference for students and clinicians regarding the efficacy and effectiveness of SMNR in wearable hearing aids. This information is useful during counseling session to build a realistic expectation among hearing aid users. Most studies in the adult population suggest that SMNR may provide some benefits to adult listeners in terms of listening

  5. Period analysis at high noise level

    International Nuclear Information System (INIS)

    Kovacs, G.

    1980-01-01

    Analytical expressions are derived for the variances of some types of the periodograms due to normal-distributed noise present in the data. The equivalence of the Jurkevich and the Warner and Robinson methods is proved. The optimum phase cell number of the Warner and Robinson method is given; this number depends on the data length, signal form and noise level. The results are illustrated by numerical examples. (orig.)

  6. Damping layout optimization for ship's cabin noise reduction based on statistical energy analysis

    Directory of Open Access Journals (Sweden)

    WU Weiguo

    2017-08-01

    Full Text Available An optimization analysis study concerning the damping control of ship's cabin noise was carried out in order to improve the effect and reduce the weight of damping. Based on the Statistical Energy Analysis (SEA method, a theoretical deduction and numerical analysis of the first-order sensitivity analysis of the A-weighted sound pressure level concerning the damping loss factor of the subsystem were carried out. On this basis, a mathematical optimization model was proposed and an optimization program developed. Next, the secondary development of VA One software was implemented through the use of MATLAB, while the cabin noise damping control layout optimization system was established. Finally, the optimization model of the ship was constructed and numerical experiments of damping control optimization conducted. The damping installation region was divided into five parts with different damping thicknesses. The total weight of damping was set as an objective function and the A-weighted sound pressure level of the target cabin was set as a constraint condition. The best damping thickness was obtained through the optimization program, and the total damping weight was reduced by 60.4%. The results show that the damping noise reduction effect of unit weight is significantly improved through the optimization method. This research successfully solves the installation position and thickness selection problems in the acoustic design of damping control, providing a reliable analysis method and guidance for the design.

  7. LOW-NOISE PAVEMENT AS A WAY OF LIMITATION OF TRAFFIC NOISE LEVEL

    Directory of Open Access Journals (Sweden)

    Władysław Gardziejczyk

    2014-11-01

    Full Text Available Road surface can significantlyreduce the trafficnoise level. Depending on the characteristic of the upper surface layers the differences between the maximum rolling noise levels from passing vehicles to reach values about 10 dB (A. A special group is low-noise pavements characterized by the presence of voids above 15%. Application the porous asphalt layers or asphalt mixture type BBTM affects a significantreduction the width of land surrounded the roads where permissible equivalent sound level is exceeded. Such solutions in some cases can replace acoustic barriers. Road pavements with a higher content of voids require proper maintenance because their acoustic performances are reduced during operation.

  8. The effect of training on noise reduction in neonatal intensive care units.

    Science.gov (United States)

    Calikusu Incekar, Mujde; Balci, Serap

    2017-07-01

    Noise, an environmental stimulus, is especially important in the neurobehavioral development of newborns and brain development of infants at high risk. Conditions in the neonatal intensive care units (NICUs) may cause certain sensory stimuli that are not appropriate for the development of newborns, especially preterm infants. This study was conducted in order to determine noise levels in the NICU and to evaluate the effect of training provided for noise control. This study was conducted as a pretest-posttest quasiexperimental design between September and November 2014 in a 30-bed NICU of a tertiary hospital in Istanbul. A sample group consisting of 30 people (26 nurses, 4 care workers). Noise measurement devices were used in the Training Program of Noise Control. Of the health professionals, 96.7% were women, 86.7% were nurses, and 63.3% were university graduates. Some 36.7% of the health professionals had worked within the unit for more than 5 years. Noise measurements of full implementations were made over three 24-h periods. Noise measurements were taken before and after the training on Monday, Friday, and Sunday. Noise levels after training diminished in all three measurements, and the decrease was found statistically significant (P Noise Control Training for health professionals who work in NICUs is an effective way of reducing noise. We recommend that this training should be given to NICU health professionals and noise levels should be determined through measurements at specific times. © 2017 Wiley Periodicals, Inc.

  9. Pediatric cT: Implementation of ASIR for Substantial Radiation Dose Reduction While Maintaining Pre-ASIR Image Noise1

    Science.gov (United States)

    Brady, Samuel L.; Moore, Bria M.; Yee, Brian S.; Kaufman, Robert A.

    2015-01-01

    Purpose To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. Materials and Methods The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current–modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. Results With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Conclusion Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose

  10. Reduction of external noise of mobile energy facilities by using active noise control system in muffler

    Science.gov (United States)

    Polivaev, O. I.; Kuznetsov, A. N.; Larionov, A. N.; Beliansky, R. G.

    2018-03-01

    The paper describes a method for the reducing emission of low-frequency noise of modern automotive vehicles into the environment. The importance of reducing the external noise of modern mobile energy facilities made in Russia is substantiated. Standard methods for controlling external noise in technology are of low efficiency when low-frequency sound waves are reduced. In this case, it is in the low-frequency zone of the sound range that the main power of the noise emitted by the machinery lies. The most effective way to reduce such sound waves is to use active noise control systems. A design of a muffler using a similar system is presented. This muffler allowed one to reduce the emission of increased noise levels into the environment by 7-11 dB and to increase acoustic comfort at the operator's workplace by 3-5 dB.

  11. Mastication noise reduction method for fully implantable hearing aid using piezo-electric sensor.

    Science.gov (United States)

    Na, Sung Dae; Lee, Gihyoun; Wei, Qun; Seong, Ki Woong; Cho, Jin Ho; Kim, Myoung Nam

    2017-07-20

    Fully implantable hearing devices (FIHDs) can be affected by generated biomechanical noise such as mastication noise. To reduce the mastication noise using a piezo-electric sensor, the mastication noise is measured with the piezo-electric sensor, and noise reduction is practiced by the energy difference. For the experiment on mastication noise, a skull model was designed using artificial skull model and a piezo-electric sensor that can measure the vibration signals better than other sensors. A 1 kHz pure-tone sound through a standard speaker was applied to the model while the lower jawbone of the model was moved in a masticatory fashion. The correlation coefficients and signal-to-noise ratio (SNR) before and after application of the proposed method were compared. It was found that the signal-to-noise ratio and correlation coefficients increased by 4.48 dB and 0.45, respectively. The mastication noise is measured by piezo-electric sensor as the mastication noise that occurred during vibration. In addition, the noise was reduced by using the proposed method in conjunction with MATLAB. In order to confirm the performance of the proposed method, the correlation coefficients and signal-to-noise ratio before and after signal processing were calculated. In the future, an implantable microphone for real-time processing will be developed.

  12. Reducing Radiation Dose in Coronary Angiography and Angioplasty Using Image Noise Reduction Technology.

    Science.gov (United States)

    Kastrati, Mirlind; Langenbrink, Lukas; Piatkowski, Michal; Michaelsen, Jochen; Reimann, Doris; Hoffmann, Rainer

    2016-08-01

    This study sought to quantitatively evaluate the reduction of radiation dose in coronary angiography and angioplasty with the use of image noise reduction technology in a routine clinical setting. Radiation dose data from consecutive 605 coronary procedures (397 consecutive coronary angiograms and 208 consecutive coronary interventions) performed from October 2014 to April 2015 on a coronary angiography system with noise reduction technology (Allura Clarity IQ) were collected. For comparison, radiation dose data from consecutive 695 coronary procedures (435 coronary angiograms and 260 coronary interventions) performed on a conventional coronary angiography system from October 2013 to April 2014 were evaluated. Patient radiation dosage was evaluated based on the cumulative dose area product. Operators and operator practice did not change between the 2 evaluated periods. Patient characteristics were collected to evaluate similarity of patient groups. Image quality was evaluated on a 5-grade scale in 30 patients of each group. There were no significant differences between the 2 evaluated groups in gender, age, weight, and fluoroscopy time (6.8 ± 6.1 vs 6.9 ± 6.3 minutes, not significant). The dose area product was reduced from 3195 ± 2359 to 983 ± 972 cGycm(2) (65%, p technology. Image quality was graded as similar between the evaluated systems (4.0 ± 0.7 vs 4.2 ± 0.6, not significant). In conclusion, a new x-ray technology with image noise reduction algorithm provides a substantial reduction in radiation exposure without the need to prolong the procedure or fluoroscopy time. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Noise reduction techniques used on the high power klystron modulators at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Russell, T.J.

    1993-01-01

    The modulators used in the Advanced Photon Source at Argonne National Laboratory have been redesigned with an emphasis on electrical noise reduction. Since the modulators are 100 MW modulators with <700 ns rise time, electrical noise can be coupled very easily to other electronic equipment in the area. This paper will detail the efforts made to reduce noise coupled to surrounding equipment. Shielding and sound grounding techniques accomplished the goal of drastically reducing the noise induced in surrounding equipment. The approach used in grounding and shielding will be discussed, and data will be presented comparing earlier designs to the improved design

  14. Adaptive nonlocal means filtering based on local noise level for CT denoising

    International Nuclear Information System (INIS)

    Li, Zhoubo; Trzasko, Joshua D.; Lake, David S.; Blezek, Daniel J.; Manduca, Armando; Yu, Lifeng; Fletcher, Joel G.; McCollough, Cynthia H.

    2014-01-01

    Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the

  15. Evaluation of noise pollution level based upon community exposure and response data

    Science.gov (United States)

    Edmiston, R. D.

    1972-01-01

    The results and procedures are reported from an evaluation of noise pollution level as a predictor of annoyance, based on aircraft noise exposure and community response data. The measures of noise exposure presented include composite noise rating, noise exposure forecast, noise and number index. A proposed measure as a universal noise exposure measure for noise pollution level (L sub NP) is discussed.

  16. Subspace-Based Noise Reduction for Speech Signals via Diagonal and Triangular Matrix Decompositions

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Søren Holdt

    2007-01-01

    We survey the definitions and use of rank-revealing matrix decompositions in single-channel noise reduction algorithms for speech signals. Our algorithms are based on the rank-reduction paradigm and, in particular, signal subspace techniques. The focus is on practical working algorithms, using both...... with working Matlab code and applications in speech processing....

  17. Profiles of noise exposure levels in South African mining

    CSIR Research Space (South Africa)

    Edwards, A

    2011-05-01

    Full Text Available were exposed to noise levels of above the 85 dBA legislated occupational exposure level. The conclusion was made that information obtained through the study could be developed into a national personal noise exposure database, including audiometric...

  18. In vivo evaluation of mastication noise reduction for dual channel implantable microphone.

    Science.gov (United States)

    Woo, SeongTak; Jung, EuiSung; Lim, HyungGyu; Lee, Jang Woo; Seong, Ki Woong; Won, Chul Ho; Kim, Myoung Nam; Cho, Jin Ho; Lee, Jyung Hyun

    2014-01-01

    Input for fully implantable hearing devices (FIHDs) is provided by an implantable microphone under the skin of the temporal bone. However, the implanted microphone can be affected when the FIHDs user chews. In this paper, a dual implantable microphone was designed that can filter out the noise from mastication. For the in vivo experiment, a fabricated microphone was implanted in a rabbit. Pure-tone sounds of 1 kHz through a standard speaker were applied to the rabbit, which was given food simultaneously. To evaluate noise reduction, the measured signals were processed using a MATLAB program based adaptive filter. To verify the proposed method, the correlation coefficients and signal to-noise ratio before and after signal processing were calculated. By comparing the results, signal-to-noise ratio and correlation coefficients are enhanced by 6.07dB and 0.529 respectively.

  19. Localized, Non-Harmonic Active Flap Motions for Low Frequency In-Plane Rotor Noise Reduction

    Science.gov (United States)

    Sim, Ben W.; Potsdam, Mark; Kitaplioglu, Cahit; LeMasurier, Philip; Lorber, Peter; Andrews, Joseph

    2012-01-01

    A first-of-its-kind demonstration of the use of localized, non-harmonic active flap motions, for suppressing low frequency, in-plane rotor noise, is reported in this paper. Operational feasibility is verified via testing of the full-scale AATD/Sikorsky/UTRC active flap demonstration rotor in the NFAC's 40- by 80-Foot anechoic wind tunnel. Effectiveness of using localized, non-harmonic active flap motions are compared to conventional four-per-rev harmonic flap motions, and also active flap motions derived from closed-loop acoustics implementations. All three approaches resulted in approximately the same noise reductions over an in-plane three-by-three microphone array installed forward and near in-plane of the rotor in the nearfield. It is also reported that using an active flap in this localized, non-harmonic manner, resulted in no more that 2% rotor performance penalty, but had the tendency to incur higher hub vibration levels.

  20. Noise and its reduction in graphene based nanopore devices

    International Nuclear Information System (INIS)

    Kumar, Ashvani; Park, Kyeong-Beom; Kim, Hyun-Mi; Kim, Ki-Bum

    2013-01-01

    Ionic current fluctuations in graphene nanopore devices are a ubiquitous phenomenon and are responsible for degraded spatial and temporal resolution. Here, we descriptively investigate the impact of different substrate materials (Si and quartz) and membrane thicknesses on noise characteristics of graphene nanopore devices. To mitigate the membrane fluctuations and pin-hole defects, a SiN x membrane is transferred onto the substrate and a pore of approximately 70 nm in diameter is perforated prior to the graphene transfer. Comprehensive noise study reveals that the few layer graphene transferred onto the quartz substrate possesses low noise level and higher signal to noise ratio as compared to single layer graphene, without deteriorating the spatial resolution. The findings here point to improvement of graphene based nanopore devices for exciting opportunities in future single-molecule genomic screening devices. (paper)

  1. Studies on assessment of traffic noise level in Aurangabad city, India

    Directory of Open Access Journals (Sweden)

    B J Bhosale

    2010-01-01

    Full Text Available With the rapid rate of urbanization of Aurangabad city due to the expanding industrialization, the problem of noise pollution has become a concern for urban dwellers and government authority too. Noise pollution due to vehicular traffic is one of the growing environmental problems of urban centers. The study deals with the assessment of traffic noise levels in Aurangabad city. With respect to the total number of vehicles passing the road in unit time, which was surveyed by direct count method, six different sites from Aurangabad city, viz., Nagar Naka, Kranti Chowk, CIDCO bus stand, Railway station area, Dhoot Hospital and Baba petrol pump were selected to study the vehicular noise level. Noise measurements were carried out at these six locations on both working day and holiday during the peak traffic hours, i.e. 8:00 a.m. - 11:a.m., 1:00 p.m. - 4:00 p.m. and 5:00 p.m. - 8:00 p.m., in the morning, afternoon and evening sessions, respectively, after 5 minutes time interval. The noise level was monitored using noise level meter. The results obtained from this investigation showed that the Nagar Naka, Kranti chowk and CIDCO bus stand area have dense traffic zones when compared with the Railway station area, Dhoot Hospital and Baba petrol pump. The minimum and the maximum noise levels are 74 and 86 dB, respectively, on working day and 70 and 81 dB, respectively, on holiday. The measured noise level values exceed the prescribed noise level.

  2. Coherent noise reduction in digital holographic microscopy by averaging multiple holograms recorded with a multimode laser.

    Science.gov (United States)

    Pan, Feng; Yang, Lizhi; Xiao, Wen

    2017-09-04

    In digital holographic microscopy (DHM), it is undesirable to observe coherent noise in the reconstructed images. The sources of the noise are mainly the parasitic interference fringes caused by multiple reflections and the speckle pattern caused by the optical scattering on the object surface. Here we propose a noise reduction approach in DHM by averaging multiple holograms recorded with a multimode laser. Based on the periodicity of the temporal coherence of a multimode semiconductor laser, we acquire a series of holograms by changing the optical path length difference between the reference beam and object beam. Because of the use of low coherence light, we can remove the parasitic interference fringes caused by multiple reflections in the holograms. In addition, the coherent noise patterns change in this process due to the different optical paths. Therefore, the coherent noise can be reduced by averaging the multiple reconstructions with uncorrelated noise patterns. Several experiments have been carried out to validate the effectiveness of the proposed approach for coherent noise reduction in DHM. It is shown a remarkable improvement both in amplitude imaging quality and phase measurement accuracy.

  3. Methods For an Acceptable Traffic Noise Level Design

    Directory of Open Access Journals (Sweden)

    Zlatko Sviben

    2004-07-01

    Full Text Available Road noise disturbance on rough roads by means of loudnesssensor caused by wideband signal components with a significantimpact of tonal effects on smooth roads and in specificactions in driving lead to the annoyance of drivers. A systemicapproach has been applied for the sound quality estimation ofphysical properties of various noise sources and structuralvibroacoustic car properties and its components as an integratedparameter in car design for the purpose of the developmentand vehicle noise reduction. Simulation of the most importantcharacteristics of listening impressions was performedby modem systems of signal analysis together with the presentationof loudness, sharpness, and roughness as essential quantities.Optimization of the noise control measuring regarding vehiclesound was obtained by means of a simulation system withthe capability of the real time original sound filtering. Structuralanalysis was performed as an acoustic modal analysis on therear part and the car interior with the quantitative analysis ofsport and luxury car sounds. The possibility of active noise controlwas studied and examples are given for an application ofpsychoacoustic tools for car sound quality design. Sound qualitywas obtained by an observation of certain aspects, which areempirically or theoretically connected with the design. An experimentalsound synthesis with psychometrical measuring wasapplied. The sound quality of car interior is presented takinginto consideration the criteria of objectivity, reliability and validity.

  4. Pilot task-based assessment of noise levels among firefighters.

    Science.gov (United States)

    Neitzel, Rl; Hong, O; Quinlan, P; Hulea, R

    2013-11-01

    Over one million American firefighters are routinely exposed to various occupational hazards agents. While efforts have been made to identify and reduce some causes of injuries and illnesses among firefighters, relatively little has been done to evaluate and understand occupational noise exposures in this group. The purpose of this pilot study was to apply a task-based noise exposure assessment methodology to firefighting operations to evaluate potential noise exposure sources, and to use collected task-based noise levels to create noise exposure estimates for evaluation of risk of noise-induced hearing loss by comparison to the 8-hr and 24-hr recommended exposure limits (RELs) for noise of 85 and 80.3 dBA, respectively. Task-based noise exposures (n=100 measurements) were measured in three different fire departments (a rural department in Southeast Michigan and suburban and urban departments in Northern California). These levels were then combined with time-at-task information collected from firefighters to estimate 8-hr noise exposures for the rural and suburban fire departments (n=6 estimates for each department). Data from 24-hr dosimetry measurements and crude self-reported activity categories from the urban fire department (n=4 measurements) were used to create 24-hr exposure estimates to evaluate the bias associated with the task-based estimates. Task-based noise levels were found to range from 82-109 dBA, with the highest levels resulting from use of saws and pneumatic chisels. Some short (e.g., 30 min) sequences of common tasks were found to result in nearly an entire allowable daily exposure. The majority of estimated 8-hr and 24-hr exposures exceeded the relevant recommended exposure limit. Predicted 24-hr exposures showed substantial imprecision in some cases, suggesting the need for increased task specificity. The results indicate potential for overexposure to noise from a variety of firefighting tasks and equipment, and suggest a need for further

  5. Elastomeric Structural Attachment Concepts for Aircraft Flap Noise Reduction - Challenges and Approaches to Hyperelastic Structural Modeling and Analysis

    Science.gov (United States)

    Sreekantamurthy, Thammaiah; Turner, Travis L.; Moore, James B.; Su, Ji

    2014-01-01

    Airframe noise is a significant part of the overall noise of transport aircraft during the approach and landing phases of flight. Airframe noise reduction is currently emphasized under the Environmentally Responsible Aviation (ERA) and Fixed Wing (FW) Project goals of NASA. A promising concept for trailing-edge-flap noise reduction is a flexible structural element or link that connects the side edges of the deployable flap to the adjacent main-wing structure. The proposed solution is distinguished by minimization of the span-wise extent of the structural link, thereby minimizing the aerodynamic load on the link structure at the expense of increased deformation requirement. Development of such a flexible structural link necessitated application of hyperelastic materials, atypical structural configurations and novel interface hardware. The resulting highly-deformable structural concept was termed the FLEXible Side Edge Link (FLEXSEL) concept. Prediction of atypical elastomeric deformation responses from detailed structural analysis was essential for evaluating feasible concepts that met the design constraints. The focus of this paper is to describe the many challenges encountered with hyperelastic finite element modeling and the nonlinear structural analysis of evolving FLEXSEL concepts. Detailed herein is the nonlinear analysis of FLEXSEL concepts that emerged during the project which include solid-section, foamcore, hollow, extended-span and pre-stressed concepts. Coupon-level analysis performed on elastomeric interface joints, which form a part of the FLEXSEL topology development, are also presented.

  6. Measured and calculated noise reduction of rail dampers and absorption plates on a high speed slab track

    NARCIS (Netherlands)

    Dittrich, M.G.; Graafland, F.; Eisses, A.R.; Nijhof, M.J.J.

    2015-01-01

    Rail dampers and sound absorbing plates have been tested on a high speed railway slab track in a walled cutting at a noise sensitive location. Their noise reduction has been determined from pass-by measurements during service and predicted using BEM calculations. The cutting depth, noise barrier

  7. Analysis of noise pollution level in a University campus in South India

    Science.gov (United States)

    Thattai, D.; Sudarsan, J. S.; Sathyanathan, R.; Ramasamy, Visalatchi

    2017-07-01

    Noise comprises those sounds occurring around us that are not part of the environment under consideration. Noise is also a type of pollution and impacts on our health and wellness. The prevalence of noise is increasing in magnitude and severity because of growing population and urbanization. Noise pollution leads to many chronic and socially significant impacts. This study analyzes the level of noise at different points in SRM University. As the University encompasses a hospital also, it is more important to identify the sources of high noise levels and control them. As per Indian standards the desirable noise pollution for educational institutions and hospitals in daytime is 50 dbA. Noise levels were measured with a sound level meter at 19 points within the campus at three different timings (8-10 am, 12-2 pm, and 3-5 pm) over two cycles of measurements. The preliminary results show higher noise levels during morning and evening. Noise during Cycle 2 (latter half of semester) was 20% more compared to that of Cycle 1 (beginning of semester).

  8. Assessment of Work Zone Noise Levels at a Cement Factory in ...

    African Journals Online (AJOL)

    Assessment of Work Zone Noise Levels at a Cement Factory in Tanga, Tanzania. ... measured in most production sections exceeded the allowed limit value of 85 ... Keywords: Noise levels, Noise exposure, Cement factory, Survey, Tanzania ...

  9. Reduction of noise influence during the periodical inspection of the nuclear power plant

    International Nuclear Information System (INIS)

    Hikono, Masaru

    2002-01-01

    At the nuclear power plant under the regular inspection, the sound level and the worker's impression of the environmental noises were measured. The environmental noise was the level with a possibility to cause the noise-induced deafness and have the psychological influence on the workers such as ''Get irritated''. These results imply the necessity of the noise countermeasure. For the noise influence relaxation, we examined the effectiveness of ear protections (e.g., ear plugs) and the intelligibility improvement of the paging system, prepared the noise management manual and the educational leaflet for the support of worker's self-defense. The results of the examinations showed that ear plug was effective especially in the high-noise environment and that the improvement of paging system increased the intelligibility. (author)

  10. Complex diffusion process for noise reduction

    DEFF Research Database (Denmark)

    Nadernejad, Ehsan; Barari, A.

    2014-01-01

    equations (PDEs) in image restoration and de-noising prompted many researchers to search for an improvement in the technique. In this paper, a new method is presented for signal de-noising, based on PDEs and Schrodinger equations, named as complex diffusion process (CDP). This method assumes that variations...... for signal de-noising. To evaluate the performance of the proposed method, a number of experiments have been performed using Sinusoid, multi-component and FM signals cluttered with noise. The results indicate that the proposed method outperforms the approaches for signal de-noising known in prior art....

  11. Comparisons of spectral characteristics of wind noise between omnidirectional and directional microphones.

    Science.gov (United States)

    Chung, King

    2012-06-01

    Wind noise reduction is a topic of ongoing research and development for hearing aids and cochlear implants. The purposes of this study were to examine spectral characteristics of wind noise generated by directional (DIR) and omnidirectional (OMNI) microphones on different styles of hearing aids and to derive wind noise reduction strategies. Three digital hearing aids (BTE, ITE, and ITC) were fitted to Knowles Electronic Manikin for Acoustic Research. They were programmed to have linear amplification and matching frequency responses between the DIR and OMNI modes. Flow noise recordings were made from 0° to 360° azimuths at flow velocities of 4.5, 9.0, and 13.5 m/s in a quiet wind tunnel. Noise levels were analyzed in one-third octave bands from 100 to 8000 Hz. Comparison of wind noise revealed that DIR generally produced higher noise levels than OMNI for all hearing aids, but it could result in lower levels than OMNI at some frequencies and head angles. Wind noise reduction algorithms can be designed to detect noise levels of DIR and OMNI outputs in each frequency channel, remove the constraint to switch to OMNI in low-frequency channel(s) only, and adopt the microphone mode with lower noise levels to take advantage of the microphone differences.

  12. Subjective annoyance caused by indoor low-level and low frequency noise and control method

    Institute of Scientific and Technical Information of China (English)

    DI Guo-qing; ZHANG Bang-jun; SHANG Qi

    2005-01-01

    The influence of low-level noise has not been widely noticed. This paper discovered that low-level and low frequency noise(Aweighted equivalent level Leq < 45 dB) causes higher probability of subjective annoyance. The fuzzy mathematic principle was applied to deal with the threshold level of subjective annoyance from noise in this study; there is preferable relationship between the indoor noise and noise annoyance at low frequency noise level. Study indicated at the same centered noise level, the change of annoyance probability is mainly caused by the change of the frequency spectrum characteristic of the indoor noise. Under low noise level environment, without change of the medium-low frequency noise, the slight increase of medium-high frequency noise level with the help of noise sheltering effect can significantly reduce the noise annoyance. This discovery brings a new resolution on how to improve the environmental quality of working or living places. A noise control model is given in this study according to the acoustic analysis.

  13. The effects of acoustical refurbishment of classrooms on teachers’ perceived noise exposure and noise-related health symptoms

    DEFF Research Database (Denmark)

    Kristiansen, Jesper; Lund, Søren Peter; Persson, Roger

    2015-01-01

    lessons with circa 2 dB(A) in both schools. Conclusion: The acoustical refurbishment was associated with a reduction in classroom reverberation time and activity sound levels in both schools. The acoustical refurbishment was associated with a reduction in the teachers’ perceived noise exposure...... of RT and activity sound levels were measured before and after refurbishment. Data on perceived noise exposure, disturbance attributed to different noise sources, voice symptoms, and fatigue after work were collected over a year in a total of six consecutive questionnaires. Results: Refurbished......, the mean classroom reverberation time was 0.68 (school A) and 0.57 (school B) and 0.55 s in sham refurbished classrooms. After refurbishment, the RT was approximately 0.4 s in both schools. Activity sound level measurements confirmed that the intervention had reduced the equivalent sound levels during...

  14. SELECTED PROBLEMS OF PROTECTION AGAINST ROAD TRAFFIC NOISE

    Directory of Open Access Journals (Sweden)

    Władysław Gardziejczyk

    2015-11-01

    Full Text Available The paper presents factors for assessment of road traffic noise level and possible actions towards the minimization of excessive noise in the roadway neighborhood. Changes of equivalent sound level values were analyzed in relation to traffic intensity, categorization and vehicles speed. In relation to measures reducing noise level in roadway’s surroundings particular attention was given to anti-noise protections and tyre/noise reduction. Acoustic effectiveness of specific solutions was showed based on chosen examples. It was proved that when admissible noise level is slightly exceeded the need for noise barrier use may be replaced by a proper design and maintenance of road pavement or by enforcement of speed limit.

  15. Sensor locations and noise reduction in high-purity batch distillation control loops

    Directory of Open Access Journals (Sweden)

    Oisiovici R.M.

    2000-01-01

    Full Text Available The influence of the sensor locations on the composition control of high-purity batch distillation columns has been investigated. Using concepts of the nonlinear control theory, an input-output linearizing controller was implemented to keep the distillate composition constant at a desired value by varying the reflux ratio. An Extended Kalman Filter was developed to estimate the compositions required in the control algorithm using temperature measurements. In the presence of measurement noise, the control performance depended greatly on the sensor locations. Placing the sensors further from the top stages reduced the detrimental effects of noise but increased the inference error. To achieve accurate composition control, both noise reduction and composition estimate accuracy should be considered in the selection of the sensor locations.

  16. Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

    Directory of Open Access Journals (Sweden)

    Fereydoon Nowshiravan Rahatabad

    2015-09-01

    Full Text Available Introduction One of the most important pre-processing steps in optical coherence tomography (OCT is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on OCT and test images. Objective evaluation of both types of images was performed, using various image metrics such as peak signal-to-noise ratio (PSNR, root mean square error, correlation coefficient and elapsed time. For the purpose of recovery, Kuan filter was used as an input for edge enhancement. Also, a spatial filter was applied to improve image quality. Results The obtained results were presented as statistical tables and images. Based on statistical measures and visual quality of OCT images, Enhanced Lee filter (3×3 with a PSNR value of 43.6735 in low noise variance and Kuan filter (3×3 with a PSNR value of 37.2850 in high noise variance showed superior performance over other filters. Conclusion Based on the obtained results, by using speckle reduction filters such as Enhanced Lee and Kuan filters on OCT images, the number of compounded images, required to achieve a given image quality, could be reduced. Moreover, use of Kuan filters for promoting the edges allowed smoothing of speckle regions, while preserving image tissue texture.

  17. Statistical CT noise reduction with multiscale decomposition and penalized weighted least squares in the projection domain

    International Nuclear Information System (INIS)

    Tang Shaojie; Tang Xiangyang

    2012-01-01

    Purposes: The suppression of noise in x-ray computed tomography (CT) imaging is of clinical relevance for diagnostic image quality and the potential for radiation dose saving. Toward this purpose, statistical noise reduction methods in either the image or projection domain have been proposed, which employ a multiscale decomposition to enhance the performance of noise suppression while maintaining image sharpness. Recognizing the advantages of noise suppression in the projection domain, the authors propose a projection domain multiscale penalized weighted least squares (PWLS) method, in which the angular sampling rate is explicitly taken into consideration to account for the possible variation of interview sampling rate in advanced clinical or preclinical applications. Methods: The projection domain multiscale PWLS method is derived by converting an isotropic diffusion partial differential equation in the image domain into the projection domain, wherein a multiscale decomposition is carried out. With adoption of the Markov random field or soft thresholding objective function, the projection domain multiscale PWLS method deals with noise at each scale. To compensate for the degradation in image sharpness caused by the projection domain multiscale PWLS method, an edge enhancement is carried out following the noise reduction. The performance of the proposed method is experimentally evaluated and verified using the projection data simulated by computer and acquired by a CT scanner. Results: The preliminary results show that the proposed projection domain multiscale PWLS method outperforms the projection domain single-scale PWLS method and the image domain multiscale anisotropic diffusion method in noise reduction. In addition, the proposed method can preserve image sharpness very well while the occurrence of “salt-and-pepper” noise and mosaic artifacts can be avoided. Conclusions: Since the interview sampling rate is taken into account in the projection domain

  18. Reduction of noise influence during the periodical inspection of the nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Hikono, Masaru [Inst. of Nuclear Safety System Inc., Mihama, Fukui (Japan)

    2002-09-01

    At the nuclear power plant under the regular inspection, the sound level and the worker's impression of the environmental noises were measured. The environmental noise was the level with a possibility to cause the noise-induced deafness and have the psychological influence on the workers such as ''Get irritated''. These results imply the necessity of the noise countermeasure. For the noise influence relaxation, we examined the effectiveness of ear protections (e.g., ear plugs) and the intelligibility improvement of the paging system, prepared the noise management manual and the educational leaflet for the support of worker's self-defense. The results of the examinations showed that ear plug was effective especially in the high-noise environment and that the improvement of paging system increased the intelligibility. (author)

  19. Environmental noise levels affect the activity budget of the Florida manatee

    Science.gov (United States)

    Miksis-Olds, Jennifer L.; Donaghay, Percy L.; Miller, James H.; Tyack, Peter L.

    2005-09-01

    Manatees inhabit coastal bays, lagoons, and estuaries because they are dependent on the aquatic vegetation that grows in shallow waters. Food requirements force manatees to occupy the same areas in which human activities are the greatest. Noise produced from human activities has the potential to affect these animals by eliciting responses ranging from mild behavioral changes to extreme aversion. This study quantifies the behavioral responses of manatees to both changing levels of ambient noise and transient noise sources. Results indicate that elevated environmental noise levels do affect the overall activity budget of this species. The proportion of time manatees spend feeding, milling, and traveling in critical habitats changed as a function of noise level. More time was spent in the directed, goal-oriented behaviors of feeding and traveling, while less time was spent milling when noise levels were highest. The animals also responded to the transient noise of approaching vessels with changes in behavioral state and movements out of the geographical area. This suggests that manatees detect and respond to changes in environmental noise levels. Whether these changes legally constitute harassment and produce biologically significant effects need to be addressed with hypothesis-driven experiments and long-term monitoring. [For Animal Bioacoustics Best Student Paper Award.

  20. Annoyance from Road Traffic, Trains, Airplanes and from Total Environmental Noise Levels.

    Science.gov (United States)

    Ragettli, Martina S; Goudreau, Sophie; Plante, Céline; Perron, Stéphane; Fournier, Michel; Smargiassi, Audrey

    2015-12-29

    There is a lack of studies assessing the exposure-response relationship between transportation noise and annoyance in North America. Our aims were to investigate the prevalence of noise annoyance induced by road traffic, trains and airplanes in relation to distance to transportation noise sources, and to total environmental noise levels in Montreal, Canada; annoyance was assessed as noise-induced disturbance. A telephone-based survey among 4336 persons aged >18 years was conducted. Exposure to total environmental noise (A-weighted outdoor noise levels-LAeq24h and day-evening-night equivalent noise levels-Lden) for each study participant was determined using a statistical noise model (land use regression-LUR) that is based on actual outdoor noise measurements. The proportion of the population annoyed by road traffic, airplane and train noise was 20.1%, 13.0% and 6.1%, respectively. As the distance to major roads, railways and the Montreal International Airport increased, the percentage of people disturbed and highly disturbed due to the corresponding traffic noise significantly decreased. When applying the statistical noise model we found a relationship between noise levels and disturbance from road traffic and total environmental noise, with Prevalence Proportion Ratios (PPR) for highly disturbed people of 1.10 (95% CI: 1.07-1.13) and 1.04 (1.02-1.06) per 1 dB(A) Lden, respectively. Our study provides the first comprehensive information on the relationship between transportation noise levels and disturbance in a Canadian city. LUR models are still in development and further studies on transportation noise induced annoyance are consequently needed, especially for sources other than road traffic.

  1. Assessment of noise level and noise propagation generated by light-lift helicopters in mountain natural environments.

    Science.gov (United States)

    Grigolato, Stefano; Mologni, Omar; Proto, Andrea Rosario; Zimbalatti, Giuseppe; Cavalli, Raffaele

    2018-01-20

    The use of helicopter rises discussion about environmental noise propagation especially when it operates in proximity of environmentally sensitive areas (ESAs) for an extended period because of its potential implications in wildlife behaviours. In order to support decisions on helicopter logging operation management in proximity of ESAs, this study focused on (i) analysing the noise spectrum of a light-lift helicopter during logging operations and on (ii) assessing the noise propagation in the surrounding environments. This study investigated a helicopter logging operation for wood fuel extraction in the eastern part of the Italian Alps. The potential disturbance area covered for the entire helicopter logging operation was evaluated by a specific GIS application according to hearing sensitivity of the most sensitive wildlife species in the study area (different strigiform species). The noise level at the ground appeared to be affected by the location regardless both the use of equivalent continuous sound pressures level dB(A) (LAeq) and the single-event level (SEL) noise metrics. The lowest values were recorded when the helicopter was flown over the sound meter level located under the forest canopy, while the highest was recorded when the helicopter was unhooking the loads at the landing. The GIS application highlighted the consistent of the exceeded noise area (weighted to strigiform hearing range and sensitivity) for the lower frequency bands (0.016-0.250 kHz). A more restricted exceeded noise area concerned instead the most sensitive frequency bands" for the strigiform (1-2 kHz). Graphical abstract ᅟ.

  2. Developmental Mechanisms Underlying Improved Contrast Thresholds for Discriminations of Orientation Signals Embedded in Noise

    Directory of Open Access Journals (Sweden)

    Seong Taek eJeon

    2014-09-01

    Full Text Available We combined an external noise paradigm with an efficient procedure for obtaining contrast thresholds (Lesmes et al., 2006 in order to model developmental changes during childhood. Specifically, we measured the contrast thresholds of 5-, 7-, 9-year-olds and adults (n = 20/age in a two alternative forced-choice orientation discrimination task over a wide range of external noise levels and at three levels of accuracy. Overall, as age increased, contrast thresholds decreased over the entire range of external noise levels tested. The decrease was greatest between 5 and 7 years of age. The reduction in threshold after age 5 was greater in the high than the low external noise region, a pattern implying greater tolerance to the irrelevant background noise as children became older. To model the mechanisms underlying these developmental changes in terms of internal noise components, we adapted the original perceptual template model (Lu and Dosher, 1998 and normalized the magnitude of performance changes against the performance of 5-year-olds. The resulting model provided an excellent fit (r2 = 0.985 to the contrast thresholds at multiple levels of accuracy (60, 75, and 90% across a wide range of external noise levels. The improvements in contrast thresholds with age were best modelled by a combination of reductions in internal additive noise, reductions in internal multiplicative noise, and improvements in excluding external noise by template retuning. In line with the data, the improvement was greatest between 5 and 7 years of age, accompanied by a 39% reduction in additive noise, 71% reduction in multiplicative noise, and 45% improvement in external noise exclusion. The modelled improvements likely reflect developmental changes at the cortical level, rather than changes in front-end structural properties (Kiorpes et al., 2003.

  3. Environmental impact of noise levels in and around opencast bauxite mine.

    Science.gov (United States)

    Kisku, G C; Barman, S C; Kidwai, M M; Bhargava, S K

    2002-01-01

    Until recently, noise pollution has not been paid adequate attention as air, water and land pollution. In order to assess (predict) the impact of bauxite mine noise on employees health and in and around bauxite mine environment, general noise sources and equipment noise were monitored. All these noise sources were compared with prescribed standard noise levels laid down by Central Pollution Control Board (CPCB). Data has also been compared with reference site, north block hill top which is barren and virgin plateau/top covered with grass only and free from human interference. Equipment noise levels were much higher than the other zone of the mine which does not have the corresponding standards. Rock breaker recorded the highest noise level with 73.1 +/- 14.2 to 89.5 +/- 10.1 dB (A) while from ripper dozer it was least with 61.0 +/- 17.3 to 76.2 +/- 6.2 dB (A). Meteorological parameters did not have much influence upon equipment noise up to 100 feet from the source.

  4. Underwater noise reduction of marine pile driving using a double pile.

    Science.gov (United States)

    2015-12-01

    Impact pile driving of steel piles in marine environments produces extremely high sound levels in the water. : It has been shown that current pile driving noise attenuation techniques, such as bubble curtains and : cofferdams, provide limited noise r...

  5. Robust spinal cord resting-state fMRI using independent component analysis-based nuisance regression noise reduction.

    Science.gov (United States)

    Hu, Yong; Jin, Richu; Li, Guangsheng; Luk, Keith Dk; Wu, Ed X

    2018-04-16

    Physiological noise reduction plays a critical role in spinal cord (SC) resting-state fMRI (rsfMRI). To reduce physiological noise and increase the robustness of SC rsfMRI by using an independent component analysis (ICA)-based nuisance regression (ICANR) method. Retrospective. Ten healthy subjects (female/male = 4/6, age = 27 ± 3 years, range 24-34 years). 3T/gradient-echo echo planar imaging (EPI). We used three alternative methods (no regression [Nil], conventional region of interest [ROI]-based noise reduction method without ICA [ROI-based], and correction of structured noise using spatial independent component analysis [CORSICA]) to compare with the performance of ICANR. Reduction of the influence of physiological noise on the SC and the reproducibility of rsfMRI analysis after noise reduction were examined. The correlation coefficient (CC) was calculated to assess the influence of physiological noise. Reproducibility was calculated by intraclass correlation (ICC). Results from different methods were compared by one-way analysis of variance (ANOVA) with post-hoc analysis. No significant difference in cerebrospinal fluid (CSF) pulsation influence or tissue motion influence were found (P = 0.223 in CSF, P = 0.2461 in tissue motion) in the ROI-based (CSF: 0.122 ± 0.020; tissue motion: 0.112 ± 0.015), and Nil (CSF: 0.134 ± 0.026; tissue motion: 0.124 ± 0.019). CORSICA showed a significantly stronger influence of CSF pulsation and tissue motion (CSF: 0.166 ± 0.045, P = 0.048; tissue motion: 0.160 ± 0.032, P = 0.048) than Nil. ICANR showed a significantly weaker influence of CSF pulsation and tissue motion (CSF: 0.076 ± 0.007, P = 0.0003; tissue motion: 0.081 ± 0.014, P = 0.0182) than Nil. The ICC values in the Nil, ROI-based, CORSICA, and ICANR were 0.669, 0.645, 0.561, and 0.766, respectively. ICANR more effectively reduced physiological noise from both tissue motion and CSF pulsation than three alternative methods. ICANR increases the robustness of SC rsf

  6. Noise sensitivity, rather than noise level, predicts the non-auditory effects of noise in community samples: a population-based survey

    Directory of Open Access Journals (Sweden)

    Jangho Park

    2017-04-01

    Full Text Available Abstract Background Excessive noise affects human health and interferes with daily activities. Although environmental noise may not directly cause mental illness, it may accelerate and intensify the development of latent mental disorders. Noise sensitivity (NS is considered a moderator of non-auditory noise effects. In the present study, we aimed to assess whether NS is associated with non-auditory effects. Methods We recruited a community sample of 1836 residents residing in Ulsan and Seoul, South Korea. From July to November 2015, participants were interviewed regarding their demographic characteristics, socioeconomic status, medical history, and NS. The non-auditory effects of noise were assessed using the Center of Epidemiologic Studies Depression, Insomnia Severity index, State Trait Anxiety Inventory state subscale, and Stress Response Inventory-Modified Form. Individual noise levels were recorded from noise maps. A three-model multivariate logistic regression analysis was performed to identify factors that might affect psychiatric illnesses. Results Participants ranged in age from 19 to 91 years (mean: 47.0 ± 16.1 years, and 37.9% (n = 696 were male. Participants with high NS were more likely to have been diagnosed with diabetes and hyperlipidemia and to use psychiatric medication. The multivariable analysis indicated that even after adjusting for noise-related variables, sociodemographic factors, medical illness, and duration of residence, subjects in the high NS group were more than 2 times more likely to experience depression and insomnia and 1.9 times more likely to have anxiety, compared with those in the low NS group. Noise exposure level was not identified as an explanatory value. Conclusions NS increases the susceptibility and hence moderates there actions of individuals to noise. NS, rather than noise itself, is associated with an elevated susceptibility to non-auditory effects.

  7. Noise aspects at aerodynamic blade optimisation projects

    Energy Technology Data Exchange (ETDEWEB)

    Schepers, J.G. [Netherlands Energy Research Foundation, Petten (Netherlands)

    1997-12-31

    This paper shows an example of an aerodynamic blade optimisation, using the program PVOPT. PVOPT calculates the optimal wind turbine blade geometry such that the maximum energy yield is obtained. Using the aerodynamic optimal blade design as a basis, the possibilities of noise reduction are investigated. The aerodynamic optimised geometry from PVOPT is the `real` optimum (up to the latest decimal). The most important conclusion from this study is, that it is worthwhile to investigate the behaviour of the objective function (in the present case the energy yield) around the optimum: If the optimum is flat, there is a possibility to apply modifications to the optimum configuration with only a limited loss in energy yield. It is obvious that the modified configurations emits a different (and possibly lower) noise level. In the BLADOPT program (the successor of PVOPT) it will be possible to quantify the noise level and hence to assess the reduced noise emission more thoroughly. At present the most promising approaches for noise reduction are believed to be a reduction of the rotor speed (if at all possible), and a reduction of the tip angle by means of low lift profiles, or decreased twist at the outboard stations. These modifications were possible without a significant loss in energy yield. (LN)

  8. Some insights into the relationship between urban air pollution and noise levels.

    Science.gov (United States)

    Kim, Ki-Hyun; Ho, Duy Xuan; Brown, Richard J C; Oh, J-M; Park, Chan Goo; Ryu, In Cheol

    2012-05-01

    The relationship between noise and air pollution was investigated in eight different districts across Seoul, Korea, between September and November 2010. The noise levels in each district were measured at both roadside and non-roadside locations. It was found that the maximum levels of noise were generally at frequencies of around 1000 Hz. The equivalent noise levels (L(eq)), over all districts, averaged 61.4 ± 7.36 dB which is slightly lower than the noise guidelines set by the World Health Organization (WHO) of 70 dB for industrial, commercial, traffic, and outdoor areas. Comparison of L(eq) levels in each district consistently indicates that noise levels are higher at roadside sites than non-roadside sites. In addition the relative dominance of noise during daytime as compared to nighttime was also apparent. Moreover, the results of an analysis relating sound levels with air pollutant levels indicate strongly that the correlation between these two parameters is the strongest at roadside sites (relative to non-roadside sites) and during nighttime (relative to daytime). The results of our data analysis point to a positive, but complex, correlation between noise levels and air pollution. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Reducing Indoor Noise Levels Using People's Perception on Greenery

    Science.gov (United States)

    Mediastika, Christina E.; Binarti, Floriberta

    2013-12-01

    Employees working in cubicles of open-plan offices in Indonesia were studied in regard to their perception on the ability of indoor greenery to reduce noise levels. Sansevieria trifasciata and Scindapsus sp were used. Each was placed in the cubicle and noise levels were measured without plants, with Sansevieria, and with Scindapsus in place. The meters showed very insignificant difference. However, responses to surveys indicated a perception of lower noise in the presence of greenery. This seemed to be supported by prior knowledge and preconception and may be useful in creating a "quieter" indoor environment.

  10. Experimental identification of noise reduction properties of honeycomb panels using a small cabin

    OpenAIRE

    D'Ortona, Vittorio; Vivolo, Marianna; Pluymers, Bert; Vandepitte, Dirk; Desmet, Wim

    2013-01-01

    A procedure to identify the noise reduction properties of panels by means of a single cabin test setup is discussed. The complexity of the sound pressure field that builds up in the acoustic volume requires the support of advanced numerical techniques allowing for the evaluation of noise and vibration performances. Numerical models are used to predict the structural dynamics and the vibro-acoustic behaviour of the tested panel. Both Finite Element and Boundary Element simulations are validate...

  11. Study on ventilation and noise reduction in the main transformer room in indoor substation

    Directory of Open Access Journals (Sweden)

    Hu Sheng

    2016-01-01

    Full Text Available The noise emission should be considered in the ventilation and cooling design for the main transformer room of indoor substation. In this study, based on Soundplan software, effects of four common ventilation and cooling schemes on the cooling and sound insulation were compared. The research showed that the region with low noise requirement, the ventilation could be set on the outer wall or on the door of the main transformer room, while the region with high noise requirement, air inlet muffler or ventilation through the cable interlayer under the main transformer room must be used. All of the four kinds of ventilation schemes, ventilation through the cable interlayer is the best in cooling and noise reduction.

  12. Noise Scaling and Community Noise Metrics for the Hybrid Wing Body Aircraft

    Science.gov (United States)

    Burley, Casey L.; Brooks, Thomas F.; Hutcheson, Florence V.; Doty, Michael J.; Lopes, Leonard V.; Nickol, Craig L.; Vicroy, Dan D.; Pope, D. Stuart

    2014-01-01

    An aircraft system noise assessment was performed for the hybrid wing body aircraft concept, known as the N2A-EXTE. This assessment is a result of an effort by NASA to explore a realistic HWB design that has the potential to substantially reduce noise and fuel burn. Under contract to NASA, Boeing designed the aircraft using practical aircraft design princip0les with incorporation of noise technologies projected to be available in the 2020 timeframe. NASA tested 5.8% scale-mode of the design in the NASA Langley 14- by 22-Foot Subsonic Tunnel to provide source noise directivity and installation effects for aircraft engine and airframe configurations. Analysis permitted direct scaling of the model-scale jet, airframe, and engine shielding effect measurements to full-scale. Use of these in combination with ANOPP predictions enabled computations of the cumulative (CUM) noise margins relative to FAA Stage 4 limits. The CUM margins were computed for a baseline N2A-EXTE configuration and for configurations with added noise reduction strategies. The strategies include reduced approach speed, over-the-rotor line and soft-vane fan technologies, vertical tail placement and orientation, and modified landing gear designs with fairings. Combining the inherent HWB engine shielding by the airframe with added noise technologies, the cumulative noise was assessed at 38.7 dB below FAA Stage 4 certification level, just 3.3 dB short of the NASA N+2 goal of 42 dB. This new result shows that the NASA N+2 goal is approachable and that significant reduction in overall aircraft noise is possible through configurations with noise reduction technologies and operational changes.

  13. Drone noise

    Science.gov (United States)

    Tinney, Charles; Sirohi, Jayant; University of Texas at Austin Team

    2017-11-01

    A basic understanding of the noise produced by single and multirotor drones operating at static thrust conditions is presented. This work acts as an extension to previous efforts conducted at The University of Texas at Austin (Tinney et al. 2017, AHS Forum 73). Propeller diameters ranging from 8 inch to 12 inch are examined for configurations comprising an isolated rotor, a quadcopter configuration and a hexacopter configuration, and with a constant drone pitch of 2.25. An azimuthal array of half-inch microphones, placed between 2 and 3 hub-center diameters from the drone center, are used to assess the acoustic near-field. Thrust levels, acquired using a six degree-of-freedom load cell, are then used to correlate acoustic noise levels to aerodynamic performance for each drone configuration. The findings reveal a nearly logarithmic increase in noise with increasing thrust. However, for the same thrust condition, considerable noise reduction is achieved by increasing the number of propeller blades thereby reducing the blade passage frequency and both the thickness and loading noise sources that accompany it.

  14. Improvement of road noise by reduction of acoustic radiation from body panels; Panel no hoshaon teigen ni yoru road noise no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Kamura, T; Utsunomiya, A; Sugihara, T; Tobita, K [Mazda Motor Corp., Hiroshima (Japan)

    1997-10-01

    This paper describes road noise reduction methods accomplished by reducing acoustic power radiated from body panels. Fundamental study of acoustic and dynamic characteristics with rectangular panels revealed following results: (1) The lower stiffness panel had lower radiation efficiency and made damping materials work more effective to reduce the acoustic power. (2) The acoustic power was also reduced by designing the panel so that it can generate the vibration of (2, 2) mode, which has the lowest radiation efficiency, in road noise frequency region. By applying these methods to a vehicle floor, we confirmed the improvement of road noise performance. 3 refs., 12 figs.

  15. [Equivalent continuous noise level in neonatal intensive care unit associated to burnout syndrome].

    Science.gov (United States)

    Garrido Galindo, A P; Camargo Caicedo, Y; Vélez-Pereira, A M

    2015-01-01

    Noise levels in neonatal intensive care units allow the appearance of symptoms associated with burnout such as stress, irritability, fatigue and emotional instability on health care personnel. The aim of this study was to evaluate the equivalent continuous noise levels in the neonatal intensive care unit and compare the results with noise levels associated with the occurrence of burnout syndrome on the care team. Continuous sampling was conducted for 20 days using a type I sound level meter on the unit. The maximum, the ninetieth percentile and the equivalent continuous noise level (Leq) values were recorded. Noise level is reported in the range of 51.4-77.6 decibels A (dBA) with an average of 64 dBA, 100.6 dBA maximum, and average background noise from 57.9 dBA. Noise levels exceed the standards suggested for neonatal intensive care units, are close to maximum values referred for noise exposure in the occupational standards and to noise levels associated with the onset of burnout; thus allowing to infer the probability of occurrence of high levels of noise present in the unit on the development of burnout in caregivers. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  16. An artificial neural network approach for aerodynamic performance retention in airframe noise reduction design of a 3D swept wing model

    Directory of Open Access Journals (Sweden)

    Tao Jun

    2016-10-01

    Full Text Available With the progress of high-bypass turbofan and the innovation of silencing nacelle in engine noise reduction, airframe noise has now become another important sound source besides the engine noise. Thus, reducing airframe noise makes a great contribution to the overall noise reduction of a civil aircraft. However, reducing airframe noise often leads to aerodynamic performance loss in the meantime. In this case, an approach based on artificial neural network is introduced. An established database serves as a basis and the training sample of a back propagation (BP artificial neural network, which uses confidence coefficient reasoning method for optimization later on. Then the most satisfactory configuration is selected for validating computations through the trained BP network. On the basis of the artificial neural network approach, an optimization process of slat cove filler (SCF for high lift devices (HLD on the Trap Wing is presented. Aerodynamic performance of both the baseline and optimized configurations is investigated through unsteady detached eddy simulations (DES, and a hybrid method, which combines unsteady DES method with acoustic analogy theory, is employed to validate the noise reduction effect. The numerical results indicate not merely a significant airframe noise reduction effect but also excellent aerodynamic performance retention simultaneously.

  17. Noise reduction in binaural hearing aids : Analyzing the benefit over monaural systems

    NARCIS (Netherlands)

    Srinivasan, S.

    2008-01-01

    Binaural beamforming using signals from both left and right hearing aids offers greater potential for noise reduction than using signals from a single aid. However, wireless transmission of data imposes power constraints. Since most modern hearing aids have multiple microphones and are capable of

  18. Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

    Science.gov (United States)

    Spalt, Taylor B.; Brooks, Thomas F.; Fuller, Christopher R.

    2012-01-01

    Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

  19. Finite element analysis using NASTRAN applied to helicopter transmission vibration/noise reduction

    Science.gov (United States)

    Howells, R. W.; Sciarra, J. J.

    1975-01-01

    A finite element NASTRAN model of the complete forward rotor transmission housing for the Boeing Vertol CH-47 helicopter was developed and applied to reduce transmission vibration/noise at its source. In addition to a description of the model, a technique for vibration/noise prediction and reduction is outlined. Also included are the dynamic response as predicted by NASTRAN, test data, the use of strain energy methods to optimize the housing for minimum vibration/noise, and determination of design modifications which will be manufactured and tested. The techniques presented are not restricted to helicopters but are applicable to any power transmission system. The transmission housing model developed can be used further to evaluate static and dynamic stresses, thermal distortions, deflections and load paths, fail-safety/vulnerability, and composite materials.

  20. A study investigating sound sources and noise levels in neonatal

    African Journals Online (AJOL)

    in Asia and sub-Saharan Africa accounting for 60% ... to identify and evaluate environmental stressors in the NICU, and to ... The findings have important implications for neonatal care, and highlight the importance of noise reduction and ...

  1. Use of the Kalman Filter for Aortic Pressure Waveform Noise Reduction.

    Science.gov (United States)

    Lam, Frank; Lu, Hsiang-Wei; Wu, Chung-Che; Aliyazicioglu, Zekeriya; Kang, James S

    2017-01-01

    Clinical applications that require extraction and interpretation of physiological signals or waveforms are susceptible to corruption by noise or artifacts. Real-time hemodynamic monitoring systems are important for clinicians to assess the hemodynamic stability of surgical or intensive care patients by interpreting hemodynamic parameters generated by an analysis of aortic blood pressure (ABP) waveform measurements. Since hemodynamic parameter estimation algorithms often detect events and features from measured ABP waveforms to generate hemodynamic parameters, noise and artifacts integrated into ABP waveforms can severely distort the interpretation of hemodynamic parameters by hemodynamic algorithms. In this article, we propose the use of the Kalman filter and the 4-element Windkessel model with static parameters, arterial compliance C , peripheral resistance R , aortic impedance r , and the inertia of blood L , to represent aortic circulation for generating accurate estimations of ABP waveforms through noise and artifact reduction. Results show the Kalman filter could very effectively eliminate noise and generate a good estimation from the noisy ABP waveform based on the past state history. The power spectrum of the measured ABP waveform and the synthesized ABP waveform shows two similar harmonic frequencies.

  2. Ambient noise levels and characterization in Aegean region, Turkey

    Science.gov (United States)

    Sevim, Fatih; Zor, Ekrem; Açıkgöz, Cem; Tarancıoğlu, Adil

    2018-03-01

    We assessed the ambient noise level in the Aegean region and analyzed its diurnal variation and its relation to the earthquake detection capability of the Aegean Region Seismic Network (ARSN). We prepared probability density functions (PDFs) for 19 broadband stations in the Aegean region operated by the Earth and Marine Sciences Institute (EMSI) of the Marmara Research Center (MRC) of the Turkish Scientific Research Council (TÜBİTAK). The power spectral densities (PSDs) used to construct PDFs for each station were computed for the periods between 0.02 and 180 s. In addition, we generated noise map of the Aegean region for different periods using the PDFs to assess the origin of the noise. We analyzed earthquake activity in the region and found that there are more local events recorded at night than during the day for each station. This difference is strongly related to diurnal variation of background noise level for the period range mostly covering the frequency range for the local events. We observed daytime noise level 15 to 20 dB higher than that at the nighttime in high frequencies for almost all stations caused by its proximity to settled areas and roads. Additionally, we observed a splitting peak within the Double Frequency (DF) microseism band; it showed a clear noise increase around the short period DF band at all the stations, decreasing inland. This peak may be related to sea waves locally generated in the Aegean Sea. We also identified a prominent increase related to marble saw companies in some stations' noise PDFs.

  3. Active Vibration Control for Helicopter Interior Noise Reduction Using Power Minimization

    Science.gov (United States)

    Mendoza, J.; Chevva, K.; Sun, F.; Blanc, A.; Kim, S. B.

    2014-01-01

    This report describes work performed by United Technologies Research Center (UTRC) for NASA Langley Research Center (LaRC) under Contract NNL11AA06C. The objective of this program is to develop technology to reduce helicopter interior noise resulting from multiple gear meshing frequencies. A novel active vibration control approach called Minimum Actuation Power (MAP) is developed. MAP is an optimal control strategy that minimizes the total input power into a structure by monitoring and varying the input power of controlling sources. MAP control was implemented without explicit knowledge of the phasing and magnitude of the excitation sources by driving the real part of the input power from the controlling sources to zero. It is shown that this occurs when the total mechanical input power from the excitation and controlling sources is a minimum. MAP theory is developed for multiple excitation sources with arbitrary relative phasing for single or multiple discrete frequencies and controlled by a single or multiple controlling sources. Simulations and experimental results demonstrate the feasibility of MAP for structural vibration reduction of a realistic rotorcraft interior structure. MAP control resulted in significant average global vibration reduction of a single frequency and multiple frequency excitations with one controlling actuator. Simulations also demonstrate the potential effectiveness of the observed vibration reductions on interior radiated noise.

  4. Ambient and at-the-ear occupational noise exposure and serum lipid levels

    DEFF Research Database (Denmark)

    Arlien-Søborg, Mai C; Schmedes, Astrid S; Stokholm, Z A

    2016-01-01

    -the-ear occupational noise exposure and serum levels of total cholesterol, low-density lipoprotein-cholesterol, high-density lipoprotein-cholesterol, and triglycerides when accounting for well-established predictors of lipid levels. METHODS: This cross-sectional study included 424 industrial workers and 84 financial......OBJECTIVES: Occupational and residential noise exposure has been related to increased risk of cardiovascular disease. Alteration of serum lipid levels has been proposed as a possible causal pathway. The objective of this study was to investigate the relation between ambient and at...... workers to obtain contrast in noise exposure levels. They provided a serum sample and wore portable dosimeters that every 5-s recorded ambient noise exposure levels during a 24-h period. We extracted measurements obtained during work and calculated the full-shift mean ambient noise level. For 331 workers...

  5. Dual-tree complex wavelet transform and SVD based acoustic noise reduction and its application in leak detection for natural gas pipeline

    Science.gov (United States)

    Yu, Xuchao; Liang, Wei; Zhang, Laibin; Jin, Hao; Qiu, Jingwei

    2016-05-01

    During the last decades, leak detection for natural gas pipeline has become one of the paramount concerns of pipeline operators and researchers across the globe. However, acoustic wave method has been proved to be an effective way to identify and localize leakage for gas pipeline. Considering the fact that noises inevitably exist in the acoustic signals collected, noise reduction should be enforced on the signals for subsequent data mining and analysis. Thus, an integrated acoustic noise reduction method based on DTCWT and SVD is proposed in this study. The method is put forward based on the idea that noise reduction strategy should match the characteristics of the noisy signal. According to previous studies, it is known that the energy of acoustic signals collected under leaking condition is mainly concentrated in low-frequency portion (0-100 Hz). And ultralow-frequency component (0-5 Hz), which is taken as the characteristic frequency band in this study, can propagate a relatively longer distance and be captured by sensors. Therefore, in order to filter the noises and to reserve the characteristic frequency band, DTCWT is taken as the core to conduct multilevel decomposition and refining for acoustic signals and SVD is employed to eliminate noises in non-characteristic bands. Both simulation and field experiments show that DTCWT-SVD is an excellent method for acoustic noise reduction. At the end of this study, application in leakage localization shows that it becomes much easier and a little more accurate to estimate the location of leak hole after noise reduction by DTCWT-SVD.

  6. A novel modulation scheme for noise reduction in analog fiber optic links

    NARCIS (Netherlands)

    Marpaung, D.A.I.; Roeloffzen, C.G.H.; van Etten, Wim

    2006-01-01

    A novel noise reduction scheme called Balanced Modulation and Detection (BMD) is proposed. In this scheme, the modulating RF signal is half-wave rectified in the optical domain, eliminating the DC optical power resulting from pre-biasing of the optical source. A link model employing this scheme has

  7. Shot noise reduction in the AlGaAs/GaAs- and InGaP/GaAs-based HBTs

    Science.gov (United States)

    Sakalas, Paulius; Schroeter, Michael; Zampardi, Peter; Zirath, Herbert

    2003-05-01

    Noise parameters of AlGaAs/GaAs and InGaP/GaAs HBTs were measured in microwave frequency range and modeled using the small-signal equivalent circuit approach. Correlated current noise sources in the base and collector currents with thermal noise in the circuit resistive elements were accounted for by the model and yielded good agreement with the measured data. This enabled an extraction of the different noise source contributions to minimum noise figure (NFmin) in AlGaAs/GaAs and InGaP/GaAs HBTs. Decomposition of the (NFmin) in to the different contributors showed that the main noise sources in investigated HBTs are correlated base and collector current shot noise. The observed minimum of NFmin versus frequency at lower collector current is explained by the reduction of the emitter/base junction shot noise component due to the spike in the emitter/base junction and associated accumulation of the quasi-thermalized electrons forming a space charge, which screens the electron transfer through the barrier. The bias (VCE) increase creates an efficient electric field in collector/base junction, capable of 'washing out' the accumulated charge. Such shot noise reduction in HBTs could be exploited in the LNA for the RF application.

  8. Supersonic impinging jet noise reduction using a hybrid control technique

    Science.gov (United States)

    Wiley, Alex; Kumar, Rajan

    2015-07-01

    Control of the highly resonant flowfield associated with supersonic impinging jet has been experimentally investigated. Measurements were made in the supersonic impinging jet facility at the Florida State University for a Mach 1.5 ideally expanded jet. Measurements included unsteady pressures on a surface plate near the nozzle exit, acoustics in the nearfield and beneath the impingement plane, and velocity field using particle image velocimetry. Both passive control using porous surface and active control with high momentum microjet injection are effective in reducing nearfield noise and flow unsteadiness over a range of geometrical parameters; however, the type of noise reduction achieved by the two techniques is different. The passive control reduces broadband noise whereas microjet injection attenuates high amplitude impinging tones. The hybrid control, a combination of two control methods, reduces both broadband and high amplitude impinging tones and surprisingly its effectiveness is more that the additive effect of the two control techniques. The flow field measurements show that with hybrid control the impinging jet is stabilized and the turbulence quantities such as streamwise turbulence intensity, transverse turbulence intensity and turbulent shear stress are significantly reduced.

  9. Reduction of airfoil trailing edge noise by trailing edge blowing

    International Nuclear Information System (INIS)

    Gerhard, T; Carolus, T; Erbslöh, S

    2014-01-01

    The paper deals with airfoil trailing edge noise and its reduction by trailing edge blowing. A Somers S834 airfoil section which originally was designed for small wind turbines is investigated. To mimic realistic Reynolds numbers the boundary layer is tripped on pressure and suction side. The chordwise position of the blowing slot is varied. The acoustic sources, i.e. the unsteady flow quantities in the turbulent boundary layer in the vicinity of the trailing edge, are quantified for the airfoil without and with trailing edge blowing by means of a large eddy simulation and complementary measurements. Eventually the far field airfoil noise is measured by a two-microphone filtering and correlation and a 40 microphone array technique. Both, LES-prediction and measurements showed that a suitable blowing jet on the airfoil suction side is able to reduce significantly the turbulence intensity and the induced surface pressure fluctuations in the trailing edge region. As a consequence, trailing edge noise associated with a spectral hump around 500 Hz could be reduced by 3 dB. For that a jet velocity of 50% of the free field velocity was sufficient. The most favourable slot position was at 90% chord length

  10. The influence of subway station design on noise levels.

    Science.gov (United States)

    Shah, Ravi R; Suen, Jonathan J; Cellum, Ilana P; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-05-01

    To investigate the impact of subway station design on platform noise levels. Observational. Continuous A-weighted decibel (dBA) sound levels were recorded in 20 New York City subway stations, where trains entered on either a straight track or curved track in 10 stations each. Equivalent continuous noise levels (L eq ) at various locations on the boarding platform (inbound end, midplatform, and outbound end) during train entry and exit were compared between the straight and curved stations in broadband as well as narrow one-third octave bands. Overall, curved stations trended louder than straight stations, although the difference in broadband L eq did not reach statistical significance (curve, 83.4 dBA; straight, 82.6 dBA; P = .054). Noise levels were significantly louder at the inbound end of the platform during train entry (inbound, 89.7 dBA; mid, 85.5 dBA; outbound, 78.7 dBA; P < .001) and at the outbound end during train exit (inbound, 79.7 dBA; mid, 85.3 dBA; outbound, 89.1 dBA; P < .001). Narrow band analysis showed that curved stations were significantly louder than straight stations at 100 Hz and high frequencies from 8 to 20 kHz. Peak impact levels ranged from 104 to 121 dBA. Curved stations have a different noise profile compared to straight stations and are significantly louder than straight stations at high frequencies. Designing stations with straight tracks within the platform can help reduce commuter noise exposure. NA Laryngoscope, 127:1169-1174, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  11. evaluation of the environmental noise levels in abuja municipality

    African Journals Online (AJOL)

    ABSTRACT. Background: Noise remains a nuisance which impacts negatively on the ..... Furthermore, Erikson et al postulated that a persistent noise level .... Hessel PA, Sluis-Cremer G K. Hearing loss in ... Ear & Hearing 2006; 27(1): 1-19. 13.

  12. Effects of self-reported sensitivity and road-traffic noise levels on the immune system.

    Directory of Open Access Journals (Sweden)

    Ahra Kim

    Full Text Available Sensitivity to noise, particularly road traffic noise, can increase cortisol levels and result in changes in immune system biomarkers. Therefore, continuous exposure to noise can have an effect on immune function, hormonal levels, and cardiovascular function, leading to hypertension and stress. The purpose of this study was to investigate the changes in stress-and immune system-related biomarkers according to the self-reported sensitivity to noise and exposure to road traffic noise, to ultimately determine the potential effects of noise on health. A survey was conducted through questionnaire (ISO/TS 15666 sent to 172 female subjects in Korea, including 128 from Ulsan and 44 from Seoul. The average noise level was calculated, and blood samples were collected for measurements of cortisol levels, Natural killer (NK / Natural killer T (NKT cell populations, and NK cell activity (through measurements of interleukin-12 (IL-12 and interferon-gamma (INF-γ concentrations. Multivariate linear regression analysis of the measured biomarkers according to the road traffic noise level and self-reported noise sensitivity was conducted adjusting for the effects of age, alcohol status, smoking status, regular exercise, and residence period. IL-12 levels increased, whereas the NKT cell population decreased with increasing noise levels. The results further suggested that cortisol levels are more influenced by the subject's sensitivity to noise than to the level of chronic road traffic noise. Therefore, noise appears to have the largest effect on IL-12 levels as well as the population and activity of NKT cells. In conclusion, our results suggest that low-level road traffic noise and sensitivity to noise can affect health by causing changes in the immune response through mechanisms other than increased cortisol.

  13. A preliminary assessment of noise level during Deepawali festival in Balasore, India.

    Science.gov (United States)

    Goswami, Shreerup; Swain, Bijay Kumar; Mohapatra, Hara Prasad; Bal, Kshirod Kumar

    2013-11-01

    A preliminary assessment of noise levels during Deepawali, was made in the present study. In order to assess the situation of noise levels in and around Balasore during two consecutive Deepawali of the year 2010 and 2011; noise monitoring was carried out in three different specified times (4:30-7:00 p.m., 7:00-10:30 p.m., 10:30 p.m.-1:00 a.m.). Noise descriptors such as L10, L50, L90, Leq, noise pollution level and noise climate were assessed to reveal the extent of noise pollution in this festival of crackers. Permissible limit of noise levels (Leq) prescribed by WHO during the festival was 100 dB and Lmax must not exceed 110 dB during such occasion. However, in all the cases Lmax and NPL values exceeded 110 dB, while Leq values ranged from 92.9 to 101.9 dB during 2010 Deepawali and 81.5 to 100.8 dB during 2011 Deepawali. On the other hand, all the noise monitoring sites belonged to residential areas. The assessed noise levels during such festivity are much more than 55/45 dB i.e. prescribed for residential areas for day/night time by CPCB. However, it was observed that the noise of Deepawali (Leq) decreased considerably and was less during 2011 than 2010. These may be due to increased environmental awareness among the public. Subsequently, the people of Balasore prefered to celebrate Deepawali, the festival of lights without sound and smoke. Noise policy should also be worked out for a better understanding of such local, social and cultural festivals in which annoyance arise.

  14. Noise: how can the nuisance be controlled?

    Science.gov (United States)

    Ollerhead, J B

    1973-09-01

    Aircraft noise is a major nuisance in residential communities around airports. If the air transport industries are to meet the ever increasing demand for air travel, determined efforts are required now to reduce the burden of noise upon these communities. Significant engine noise reductions have already been achieved in the latest generation of wide-bodied aircraft, and further reductions are being forecast by the engine manufacturers. Regardless of whether there are justifiable grounds for this optimism there are alternative steps to be taken. But the problem is basically an economic rather than a technological one - how much does noise reduction cost and how much can we afford to pay? The various costs of aircraft noise, both monetary and social, are discussed in relation to its effects upon people. Although an economic analysis of the problem is feasible, it is doubtful whether our understanding of the relationships between physical noise levels and human reaction is yet adequate for such purposes. Planning methods for estimating the extent of community noise nuisance are presented, and it is shown that consideration should be given to outlying regions exposed to relatively little aircraft noise.

  15. Noise-induced hearing loss: a recreational noise perspective.

    Science.gov (United States)

    Ivory, Robert; Kane, Rebecca; Diaz, Rodney C

    2014-10-01

    This review will discuss the real-world risk factors involved in noise-induced hearing loss as a result of common and popular recreational activities prone to mid and high levels of noise exposure. Although there are currently no interventional measures available to reverse or mitigate preexisting hearing loss from noise, we discuss the vital importance of hearing loss prevention from noise exposure avoidance and reduction. Despite a seeming understanding of the effects of noise exposure from various recreational activities and devices, a large percentage of the general public who is at risk of such noise-induced hearing loss still chooses to refrain from using hearing protection instruments. While occupational exposures pose the greatest traditional risk to hearing conservation in selected workers, recreational risk factors for noise-induced hearing loss may be more insidious in overall effect given the indifferent attitude of much of the general public and particularly our youths toward hearing protection during recreational activities. Active counseling regarding the consequences of excessive noise exposure and the potential benefits to hearing from usage of hearing protection instruments is critical to providing best possible care in the hearing health professions.

  16. Ambient noise levels in the Taiwan region

    Science.gov (United States)

    Liang, W.; Liu, C.; Chen, R.; Huang, B.; Wu, F. T.; Wang, C.

    2008-12-01

    To characterize the island-wide background seismic noise in Taiwan, we estimate the power spectral density (PSD) at broadband stations of both the BATS (Broadband Array in Taiwan for Seismology) and the TAIGER experiment (Apr. 2006~Apr. 2008) for periods ranging from ~0.2 to 100 seconds. A new approach to calculate the probability density functions of noise power (PDFs, MaNamara and Buland, 2004) is used in this study. The results indicate that the cultural noise at higher frequencies is significant at populated area, which shows diurnal and weekly variation as what we expected. The noise power for microseisms centered at a period of ~5 seconds around the western costal plain show ~20dB higher than what observed at eastern Taiwan. This observation supports the inference that the coastal regions having narrow shelf with irregular coastlines are know to be especially efficient at radiating the predominat microseisms. Results from the linear array across central Taiwan demonstrate that the average noise power is quietest at the eastern Central Range. We have mapped the PDF mode for stations at various periods to see the spatial distribution of ambient noise levels, which could be used as the basic information for future station siting. Temporal variation of noise PSD is also present to provide a quantitative description of the seismic data quality collected by both BATS and TAIGER experiment. Some operational problems like base tilt, sensitivity change can be identified easily as well.

  17. Noise levels of neonatal high-flow nasal cannula devices--an in-vitro study.

    Science.gov (United States)

    König, Kai; Stock, Ellen L; Jarvis, Melanie

    2013-01-01

    Excessive ambient noise levels have been identified as a potential risk factor for adverse outcome in very preterm infants. Noise level measurements for continuous positive airway pressure (CPAP) devices demonstrated that these constantly exceed current recommendations. The use of high-flow nasal cannula (HFNC) as an alternative non-invasive ventilation modality has become more popular in recent years in neonatal care. To study noise levels of two HFNC devices commonly used in newborns. As a comparison, noise levels of a continuous flow CPAP device were also studied. In-vitro study. The noise levels of two contemporary HFNC devices (Fisher & Paykel NHF™ and Vapotherm Precision Flow®) and one CPAP device (Dräger Babylog® 8000 plus) were measured in the oral cavity of a newborn manikin in an incubator in a quiet environment. HFNC flows of 4-8 l/min and CPAP pressures of 4-8 cm H2O were applied. The CPAP flow was set at 8 l/min as per unit practice. Vapotherm HFNC generated the highest noise levels, measuring 81.2-91.4 dB(A) with increasing flow. Fisher & Paykel HFNC noise levels were between 78.8 and 81.2 dB(A). The CPAP device generated the lowest noise levels between 73.9 and 77.4 dB(A). Both HFNC devices generated higher noise levels than the CPAP device. All noise levels were far above current recommendations of the American Academy of Pediatrics. In light of the long duration of non-invasive respiratory support of very preterm infants, less noisy devices are required to prevent the potentially adverse effects of continuing excessive noise exposure in the neonatal intensive care unit. Copyright © 2013 S. Karger AG, Basel.

  18. Variations in the microseismic noise level observed at the Bucovina Seismic Array (BURAR)

    International Nuclear Information System (INIS)

    Ghica, Daniela; Radulian, Mircea; Popa, Mihaela

    2005-01-01

    The microseismic noise level analysis for a seismic array is an essential step to accurately process the data recorded by the system. Basically, the observed background noise is a complex combination of natural and cultural sources as local geology, specific area activity (roads traffic, agricultural and industrial activities) or weather conditions.The understanding of the BURAR site noise characteristics is important for the array specific techniques (beamforming, f-k analysis), to apply the correct bandpass filtering, in order to obtain noise suppression and conservation of the 'true' seismic signal. The array monitoring potential of very small earthquakes and explosions will be enhanced, based on the best signal-to-noise ratio.The noise study at BURAR was carried out over one-year period, considering the noise power spectra in a 0.1 to 10 Hz frequency interval, for every 24 hours: 5 minutes during day and 5 minutes during night. Only short-period vertical sensors were considered. Systematic variations in the microseismic noise level at the BURAR site were observed:- diurnal: a decreasing of about 40% in night noise level at 1 Hz frequency; at 6 Hz frequency, the decreasing could reach 80-90% for 'non-winter' months (May to October); - seasonal: during the winter time, a lower noise level is observed, due to the restraining of the local specific activity (especially agriculture and farming) and of the road traffic. To summarize the level of microseismic noise observed at BURAR for one-year observations, a model curve for array noise level has been estimated, including upper and lower bounds of noise power density together with average spectrum. The BURAR noise model will be useful in the process of local site conditions estimation, by eliminating the noise contribution from the array recording. Also, the detection processing, phase identification and events location procedures will be significantly improved. (authors)

  19. Predictive modelling of noise level generated during sawing of rocks

    Indian Academy of Sciences (India)

    This paper presents an experimental and statistical study on noise level generated during of rock sawing by circular diamond sawblades. Influence of the operating variables and rock properties on the noise level are investigated and analysed. Statistical analyses are then employed and models are built for the prediction of ...

  20. Potential of neuro-fuzzy methodology to estimate noise level of wind turbines

    Science.gov (United States)

    Nikolić, Vlastimir; Petković, Dalibor; Por, Lip Yee; Shamshirband, Shahaboddin; Zamani, Mazdak; Ćojbašić, Žarko; Motamedi, Shervin

    2016-01-01

    Wind turbines noise effect became large problem because of increasing of wind farms numbers since renewable energy becomes the most influential energy sources. However, wind turbine noise generation and propagation is not understandable in all aspects. Mechanical noise of wind turbines can be ignored since aerodynamic noise of wind turbine blades is the main source of the noise generation. Numerical simulations of the noise effects of the wind turbine can be very challenging task. Therefore in this article soft computing method is used to evaluate noise level of wind turbines. The main goal of the study is to estimate wind turbine noise in regard of wind speed at different heights and for different sound frequency. Adaptive neuro-fuzzy inference system (ANFIS) is used to estimate the wind turbine noise levels.

  1. Noise-level determination for discrete spectra with Gaussian or Lorentzian probability density functions

    International Nuclear Information System (INIS)

    Moriya, Netzer

    2010-01-01

    A method, based on binomial filtering, to estimate the noise level of an arbitrary, smoothed pure signal, contaminated with an additive, uncorrelated noise component is presented. If the noise characteristics of the experimental spectrum are known, as for instance the type of the corresponding probability density function (e.g., Gaussian), the noise properties can be extracted. In such cases, both the noise level, as may arbitrarily be defined, and a simulated white noise component can be generated, such that the simulated noise component is statistically indistinguishable from the true noise component present in the original signal. In this paper we present a detailed analysis of the noise level extraction when the additive noise is Gaussian or Lorentzian. We show that the statistical parameters in these cases (mainly the variance and the half width at half maximum, respectively) can directly be obtained from the experimental spectrum even when the pure signal is erratic. Further discussion is given for cases where the noise probability density function is initially unknown.

  2. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Andreas; Wigstroem, Lars; Hofmann, Hannes G.; Hornegger, Joachim; Zhu Lei; Strobel, Norbert; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Department of Radiology, Stanford University, Stanford, California 94305 (United States) and Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping (Sweden); Pattern Recognition Laboratory, Department of Computer Science, Friedrich-Alexander University of Erlangen-Nuremberg, 91054, Erlangen (Germany); Nuclear and Radiological Engineering and Medical Physics Programs, George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Siemens AG Healthcare, Forchheim 91301 (Germany); Department of Radiology, Stanford University, Stanford, California 94305 (United States)

    2011-11-15

    Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8

  3. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

    International Nuclear Information System (INIS)

    Maier, Andreas; Wigstroem, Lars; Hofmann, Hannes G.; Hornegger, Joachim; Zhu Lei; Strobel, Norbert; Fahrig, Rebecca

    2011-01-01

    Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold

  4. Industrial noise level study in a wheat processing factory in ilorin, nigeria

    Science.gov (United States)

    Ibrahim, I.; Ajao, K. R.; Aremu, S. A.

    2016-05-01

    An industrial process such as wheat processing generates significant noise which can cause adverse effects on workers and the general public. This study assessed the noise level at a wheat processing mill in Ilorin, Nigeria. A portable digital sound level meter HD600 manufactured by Extech Inc., USA was used to determine the noise level around various machines, sections and offices in the factory at pre-determined distances. Subjective assessment was also mode using a World Health Organization (WHO) standard questionnaire to obtain information regarding noise ratings, effect of noise on personnel and noise preventive measures. The result of the study shows that the highest noise of 99.4 dBA was recorded at a pressure blower when compared to other machines. WHO Class-4 hearing protector is recommended for workers on the shop floor and room acoustics should be upgraded to absorb some sounds transmitted to offices.

  5. Noise Reduction with Optimal Variable Span Linear Filters

    DEFF Research Database (Denmark)

    Jensen, Jesper Rindom; Benesty, Jacob; Christensen, Mads Græsbøll

    2016-01-01

    In this paper, the problem of noise reduction is addressed as a linear filtering problem in a novel way by using concepts from subspace-based enhancement methods, resulting in variable span linear filters. This is done by forming the filter coefficients as linear combinations of a number...... included in forming the filter. Using these concepts, a number of different filter designs are considered, like minimum distortion, Wiener, maximum SNR, and tradeoff filters. Interestingly, all these can be expressed as special cases of variable span filters. We also derive expressions for the speech...... demonstrate the advantages and properties of the variable span filter designs, and their potential performance gain compared to widely used speech enhancement methods....

  6. A comparison of high-frequency noise levels on Cascadia Initiative ocean-bottom seismometers

    Science.gov (United States)

    Hilmo, R.; Wilcock, W. S. D.; Roland, E. C.; Bodin, P.; Connolly, J.

    2017-12-01

    The Cascadia Initiative (CI) included a four-year deployment of 70 ocean bottom seismometers (OBSs) on the Cascadia subduction zone and the Juan de Fuca plate for the purposes of characterizing seismicity and imaging the Earth's interior. The Cascadia subduction zone megathrust exhibits very low rates of seismicity relative to most other subduction zones, and there is great motivation to understand deformation on the megathrust because of its potential to produce a catastrophic M9 earthquake. An understanding of earthquake detectability of the CI network, based on knowledge of noise levels, could contribute to the interpretation of earthquake catalogs derived from the experiment and aid in the design of future networks. This project is aimed at estimating these thresholds of local earthquake detectability and how they change across the array both geographically and temporally. We characterize background noise levels recorded from 0.1 to 20 Hz with an emphasis on the frequency band used to detect local seismicity ( 3-15 Hz) to understand how noise levels depend on instrument design and environmental parameters including seafloor depth, season and oceanographic conditions. Our initial analysis of 3 weeks of vertical channel data in September, January, and May 2012-2013 shows that noise increase significantly moving from the continental shelf to deeper water. Noise levels at a given depth vary with instrument type but further analysis is required to determine whether this reflects variations in instrumental noise and ground coupling noise or errors in the scaling of the instrument response. There is also a strong seasonality in recorded noise levels at some frequencies, with winter noise levels exceeding spring and fall noise levels by up to 10 decibels in both the microseism band and in the fin whale calling band (15-20 Hz). In contrast, the seasonal noise level in the local seismicity band for a given instrument type and location shows smaller noise variation

  7. Statistics of A-weighted road traffic noise levels in shielded urban areas

    NARCIS (Netherlands)

    Forssén, J.; Hornikx, M.C.J.

    2006-01-01

    In the context of community noise and its negative effects, the noise descriptors used are usually long-term equivalent levels and, sometimes, maximum levels. An improved description could be achieved by including the time variations of the noise. Here, the time variations of A-weighted road traffic

  8. Annoyance from Road Traffic, Trains, Airplanes and from Total Environmental Noise Levels

    Directory of Open Access Journals (Sweden)

    Martina S. Ragettli

    2015-12-01

    Full Text Available There is a lack of studies assessing the exposure-response relationship between transportation noise and annoyance in North America. Our aims were to investigate the prevalence of noise annoyance induced by road traffic, trains and airplanes in relation to distance to transportation noise sources, and to total environmental noise levels in Montreal, Canada; annoyance was assessed as noise-induced disturbance. A telephone-based survey among 4336 persons aged >18 years was conducted. Exposure to total environmental noise (A-weighted outdoor noise levels—LAeq24h and day-evening-night equivalent noise levels—Lden for each study participant was determined using a statistical noise model (land use regression—LUR that is based on actual outdoor noise measurements. The proportion of the population annoyed by road traffic, airplane and train noise was 20.1%, 13.0% and 6.1%, respectively. As the distance to major roads, railways and the Montreal International Airport increased, the percentage of people disturbed and highly disturbed due to the corresponding traffic noise significantly decreased. When applying the statistical noise model we found a relationship between noise levels and disturbance from road traffic and total environmental noise, with Prevalence Proportion Ratios (PPR for highly disturbed people of 1.10 (95% CI: 1.07–1.13 and 1.04 (1.02–1.06 per 1 dB(A Lden, respectively. Our study provides the first comprehensive information on the relationship between transportation noise levels and disturbance in a Canadian city. LUR models are still in development and further studies on transportation noise induced annoyance are consequently needed, especially for sources other than road traffic.

  9. Annoyance from Road Traffic, Trains, Airplanes and from Total Environmental Noise Levels

    Science.gov (United States)

    Ragettli, Martina S.; Goudreau, Sophie; Plante, Céline; Perron, Stéphane; Fournier, Michel; Smargiassi, Audrey

    2015-01-01

    There is a lack of studies assessing the exposure-response relationship between transportation noise and annoyance in North America. Our aims were to investigate the prevalence of noise annoyance induced by road traffic, trains and airplanes in relation to distance to transportation noise sources, and to total environmental noise levels in Montreal, Canada; annoyance was assessed as noise-induced disturbance. A telephone-based survey among 4336 persons aged >18 years was conducted. Exposure to total environmental noise (A-weighted outdoor noise levels—LAeq24h and day-evening-night equivalent noise levels—Lden) for each study participant was determined using a statistical noise model (land use regression—LUR) that is based on actual outdoor noise measurements. The proportion of the population annoyed by road traffic, airplane and train noise was 20.1%, 13.0% and 6.1%, respectively. As the distance to major roads, railways and the Montreal International Airport increased, the percentage of people disturbed and highly disturbed due to the corresponding traffic noise significantly decreased. When applying the statistical noise model we found a relationship between noise levels and disturbance from road traffic and total environmental noise, with Prevalence Proportion Ratios (PPR) for highly disturbed people of 1.10 (95% CI: 1.07–1.13) and 1.04 (1.02–1.06) per 1 dB(A) Lden, respectively. Our study provides the first comprehensive information on the relationship between transportation noise levels and disturbance in a Canadian city. LUR models are still in development and further studies on transportation noise induced annoyance are consequently needed, especially for sources other than road traffic. PMID:26729143

  10. Noise Reduction planar bone imaging nuclear medicine with the use of wavelet transform: an assessment of its quality

    International Nuclear Information System (INIS)

    Casas Cardoso, Maria del Carmen; Perez Diaz, Marlen; Casas Cardoso, Gladis; Lorenzo Ginori, Juan; Paz Viera, Juan Enrique; Roque Diaz, Reinaldo; Cardenas Barreras, Julian

    2009-01-01

    Diagnostic imaging of Nuclear Medicine (MN), is highly used in Oncology, as it constitutes a noninvasive technique that allows early detection of tumors and assessment of therapeutic response of patients under treatment. However, particularly planar scintigraphy images, can be prone to problems of detectability of small lesions, because they are contaminated with noise, a phenomenon which is accentuated by the inability to increase the dose of the radiopharmaceutical or time acquisition of images of the patient over 'certain levels'. The aim of this work is to improve the detectability of tumors of bone. We describe an algorithm for random noise reduction using the wavelet transform (TW). The quality of the resulting images are evaluated through quantitative metrics such as Signal to Noise Ratio (SNR), the Mean Square Error (NMSEA) and Structural Similarity Index (SSIM). It also includes a subjective assessment of image quality by expert criteria, using a variant of the methodology FROC (Free-Response ROC). It was found that some of the filters designed in the wavelet domain, significantly improve the quality of planar bone imaging in terms of increased signal to noise ratio without implying notable structural distortions, which facilitates clinical diagnosis. (author)

  11. A Noise Reduction Method for Dual-Mass Micro-Electromechanical Gyroscopes Based on Sample Entropy Empirical Mode Decomposition and Time-Frequency Peak Filtering.

    Science.gov (United States)

    Shen, Chong; Li, Jie; Zhang, Xiaoming; Shi, Yunbo; Tang, Jun; Cao, Huiliang; Liu, Jun

    2016-05-31

    The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.

  12. A Noise Reduction Method for Dual-Mass Micro-Electromechanical Gyroscopes Based on Sample Entropy Empirical Mode Decomposition and Time-Frequency Peak Filtering

    Directory of Open Access Journals (Sweden)

    Chong Shen

    2016-05-01

    Full Text Available The different noise components in a dual-mass micro-electromechanical system (MEMS gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN, electronic-thermal noise (ETN, flicker noise (FN and Coriolis signal in-phase noise (IPN. The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD and time-frequency peak filtering (TFPF. There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.

  13. Adaptive non-local means on local principle neighborhood for noise/artifacts reduction in low-dose CT images.

    Science.gov (United States)

    Zhang, Yuanke; Lu, Hongbing; Rong, Junyan; Meng, Jing; Shang, Junliang; Ren, Pinghong; Zhang, Junying

    2017-09-01

    Low-dose CT (LDCT) technique can reduce the x-ray radiation exposure to patients at the cost of degraded images with severe noise and artifacts. Non-local means (NLM) filtering has shown its potential in improving LDCT image quality. However, currently most NLM-based approaches employ a weighted average operation directly on all neighbor pixels with a fixed filtering parameter throughout the NLM filtering process, ignoring the non-stationary noise nature of LDCT images. In this paper, an adaptive NLM filtering scheme on local principle neighborhoods (PC-NLM) is proposed for structure-preserving noise/artifacts reduction in LDCT images. Instead of using neighboring patches directly, in the PC-NLM scheme, the principle component analysis (PCA) is first applied on local neighboring patches of the target patch to decompose the local patches into uncorrelated principle components (PCs), then a NLM filtering is used to regularize each PC of the target patch and finally the regularized components is transformed to get the target patch in image domain. Especially, in the NLM scheme, the filtering parameter is estimated adaptively from local noise level of the neighborhood as well as the signal-to-noise ratio (SNR) of the corresponding PC, which guarantees a "weaker" NLM filtering on PCs with higher SNR and a "stronger" filtering on PCs with lower SNR. The PC-NLM procedure is iteratively performed several times for better removal of the noise and artifacts, and an adaptive iteration strategy is developed to reduce the computational load by determining whether a patch should be processed or not in next round of the PC-NLM filtering. The effectiveness of the presented PC-NLM algorithm is validated by experimental phantom studies and clinical studies. The results show that it can achieve promising gain over some state-of-the-art methods in terms of artifact suppression and structure preservation. With the use of PCA on local neighborhoods to extract principal structural

  14. Experimental investigation of wavy leading edges on rod-aerofoil interaction noise

    Science.gov (United States)

    Chen, Weijie; Qiao, Weiyang; Tong, Fan; Wang, Liangfeng; Wang, Xunnian

    2018-05-01

    Experimental studies are performed to investigate the effect of wavy leading edges on rod-aerofoil interaction noise in an open-jet anechoic wind tunnel. NACA 0012 aerofoils with straight and wavy leading edges (denoted by SLE and WLE, respectively) are embedded in the wake of a circular rod. The WLEs are in the form of sinusoidal profiles of amplitude, A, and wavelength, W. Parametric studies of the amplitude and wavelength characteristics are conducted to understand the effect of WLEs on noise reduction. It is observed that the sound power reduction level is sensitive to both the amplitude and wavelength of the WLEs. The WLE with the largest amplitude and smallest wavelength can achieve the most considerable noise reduction effect of up to 4 dB. The influences of rod diameter, d, and free-stream velocity, U0, on the noise reduction effect of the WLEs are also investigated. In addition, a parametric study of the influence of separating rod-aerofoil distance on the acoustic radiation of the SLE case and on the sound power reduction level of the WLE cases is performed. It is found that a critical spacing exists where the acoustic radiation and noise reduction can be divided into two different "modes".

  15. The effect of oblique angle of sound incidence, realistic edge conditions, curvature and in-plane panel stresses on the noise reduction characteristics of general aviation type panels

    Science.gov (United States)

    Grosveld, F.; Lameris, J.; Dunn, D.

    1979-01-01

    Experiments and a theoretical analysis were conducted to predict the noise reduction of inclined and curved panels. These predictions are compared to the experimental results with reasonable agreement between theory and experiment for panels under an oblique angle of sound incidence. Theoretical as well as experimental results indicate a big increase in noise reduction when a flat test panel is curved. Further curving the panel slightly decreases the noise reduction. Riveted flat panels are shown to give a higher noise reduction in the stiffness-controlled frequency region, while bonded panels are superior in this region when the test panel is curved. Experimentally measured noise reduction characteristics of flat aluminum panels with uniaxial in-plane stresses are presented and discussed. These test results indicate an important improvement in the noise reduction of these panels in the frequency range below the fundamental panel/cavity frequency.

  16. Neural indices of phonemic discrimination and sentence-level speech intelligibility in quiet and noise: A P3 study.

    Science.gov (United States)

    Koerner, Tess K; Zhang, Yang; Nelson, Peggy B; Wang, Boxiang; Zou, Hui

    2017-07-01

    This study examined how speech babble noise differentially affected the auditory P3 responses and the associated neural oscillatory activities for consonant and vowel discrimination in relation to segmental- and sentence-level speech perception in noise. The data were collected from 16 normal-hearing participants in a double-oddball paradigm that contained a consonant (/ba/ to /da/) and vowel (/ba/ to /bu/) change in quiet and noise (speech-babble background at a -3 dB signal-to-noise ratio) conditions. Time-frequency analysis was applied to obtain inter-trial phase coherence (ITPC) and event-related spectral perturbation (ERSP) measures in delta, theta, and alpha frequency bands for the P3 response. Behavioral measures included percent correct phoneme detection and reaction time as well as percent correct IEEE sentence recognition in quiet and in noise. Linear mixed-effects models were applied to determine possible brain-behavior correlates. A significant noise-induced reduction in P3 amplitude was found, accompanied by significantly longer P3 latency and decreases in ITPC across all frequency bands of interest. There was a differential effect of noise on consonant discrimination and vowel discrimination in both ERP and behavioral measures, such that noise impacted the detection of the consonant change more than the vowel change. The P3 amplitude and some of the ITPC and ERSP measures were significant predictors of speech perception at segmental- and sentence-levels across listening conditions and stimuli. These data demonstrate that the P3 response with its associated cortical oscillations represents a potential neurophysiological marker for speech perception in noise. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Detection System of Sound Noise Level (SNL) Based on Condenser Microphone Sensor

    Science.gov (United States)

    Rajagukguk, Juniastel; Eka Sari, Nurdieni

    2018-03-01

    The research aims to know the noise level by using the Arduino Uno as data processing input from sensors and called as Sound Noise Level (SNL). The working principle of the instrument is as noise detector with the show notifications the noise level on the LCD indicator and in the audiovisual form. Noise detection using the sensor is a condenser microphone and LM 567 as IC op-amps, which are assembled so that it can detect the noise, which sounds are captured by the sensor will turn the tide of sinusoida voice became sine wave energy electricity (altering sinusoida electric current) that is able to responded to complaints by the Arduino Uno. The tool is equipped with a detector consists of a set indicator LED and sound well as the notification from the text on LCD 16*2. Work setting indicators on the condition that, if the measured noise > 75 dB then sound will beep, the red LED will light up indicating the status of the danger. If the measured value on the LCD is higher than 56 dB, sound indicator will be beep and yellow LED will be on indicating noisy. If the noise measured value <55 dB, sound indicator will be quiet indicating peaceful from noisy. From the result of the research can be explained that the SNL is capable to detecting and displaying noise level with a measuring range 50-100 dB and capable to delivering the notification noise in audiovisual.

  18. Preferred listening levels of mobile phone programs when considering subway interior noise

    Directory of Open Access Journals (Sweden)

    Jyaehyoung Yu

    2016-01-01

    Full Text Available Today, people listen to music loud using personal listening devices. Although a majority of studies have reported that the high volume played on these listening devices produces a latent risk of hearing problems, there is a lack of studies on "double noise exposures" such as environmental noise plus recreational noise. The present study measures the preferred listening levels of a mobile phone program with subway interior noise for 74 normal-hearing participants in five age groups (ranging from 20s to 60s. The speakers presented the subway interior noise at 73.45 dB, while each subject listened to three application programs [Digital Multimedia Broadcasting (DMB, music, game] for 30 min using a tablet personal computer with an earphone. The participants′ earphone volume levels were analyzed using a sound level meter and a 2cc coupler. Overall, the results showed that those in their 20s listened to the three programs significantly louder with DMB set at significantly higher volume levels than for the other programs. Higher volume levels were needed for middle frequency compared to the lower and higher frequencies. We concluded that any potential risk of noise-induced hearing loss for mobile phone users should be communicated when users listen regularly, although the volume level was not high enough that the users felt uncomfortable. When considering individual listening habits on mobile phones, further study to predict total accumulated environmental noise is still needed.

  19. Preferred listening levels of mobile phone programs when considering subway interior noise.

    Science.gov (United States)

    Yu, Jyaehyoung; Lee, Donguk; Han, Woojae

    2016-01-01

    Today, people listen to music loud using personal listening devices. Although a majority of studies have reported that the high volume played on these listening devices produces a latent risk of hearing problems, there is a lack of studies on "double noise exposures" such as environmental noise plus recreational noise. The present study measures the preferred listening levels of a mobile phone program with subway interior noise for 74 normal-hearing participants in five age groups (ranging from 20s to 60s). The speakers presented the subway interior noise at 73.45 dB, while each subject listened to three application programs [Digital Multimedia Broadcasting (DMB), music, game] for 30 min using a tablet personal computer with an earphone. The participants' earphone volume levels were analyzed using a sound level meter and a 2cc coupler. Overall, the results showed that those in their 20s listened to the three programs significantly louder with DMB set at significantly higher volume levels than for the other programs. Higher volume levels were needed for middle frequency compared to the lower and higher frequencies. We concluded that any potential risk of noise-induced hearing loss for mobile phone users should be communicated when users listen regularly, although the volume level was not high enough that the users felt uncomfortable. When considering individual listening habits on mobile phones, further study to predict total accumulated environmental noise is still needed.

  20. On the dynamics of the preference-performance relation for hearing aid noise reduction

    DEFF Research Database (Denmark)

    Fischer, Rosa-Linde; Wagener, Kirsten C.; Vormann, Matthias

    on the data collected during the first laboratory assessment of the study. In particular, the influence of hearing aid experience and individual noise sensitivity on the preference-performance relation will be presented and discussed. REFERENCES S. Getzmann, E. Wascher and M. Falkenstein (2015). "What does......Previous research has shown that hearing aid users can differ substantially in their preference for noise reduction (NR) strength, and that preference for and speech recognition with NR processing typically are not correlated (e.g. Neher 2014; Serman et al. 2016). In other words, hearing aid users...... may prefer a certain NR setting, but perform better with a different one. The aim of the present work was to investigate the influence of individual noise sensitivity, hearing aid experience and acclimatization on the preference-performance relation for different NR settings. For this purpose...

  1. Measurement of speech levels in the presence of time varying background noise

    Science.gov (United States)

    Pearsons, K. S.; Horonjeff, R.

    1982-01-01

    Short-term speech level measurements which could be used to note changes in vocal effort in a time varying noise environment were studied. Knowing the changes in speech level would in turn allow prediction of intelligibility in the presence of aircraft flyover noise. Tests indicated that it is possible to use two second samples of speech to estimate long term root mean square speech levels. Other tests were also performed in which people read out loud during aircraft flyover noise. Results of these tests indicate that people do indeed raise their voice during flyovers at a rate of about 3-1/2 dB for each 10 dB increase in background level. This finding is in agreement with other tests of speech levels in the presence of steady state background noise.

  2. Prediction and comparison of noise levels from ground and elevated flare systems

    International Nuclear Information System (INIS)

    Obasi, E.

    2009-01-01

    Flaring is a process to dispose of hydrocarbons during clean-up, emergency shut downs or dispose a small volume waste streams of mixed gasses that cannot easily or safely be separated. This presentation discussed flaring as a noise issue. It focused on flaring noise characterization; flare noise modeling; flare sound power levels; and flare sound pressure level comparison at a distance of 1.5 km. The presentation included a photograph of flaring at a gas plant in Nigeria. The presentation listed some of the potential health effects associated with long term exposure to excessive noise, such as hearing loss; headaches; stress; fatigue; sleep disturbance; and high blood pressure. Companies flare gas to dispose waste gases in a safe and reliable manner through combustion and to depressurize gas lines during maintenance and emergencies. This presentation also discussed ground and elevated flares; components of flare noise characterization; and key factors affecting flare noise. A model to predict flaring noise was also presented. It demonstrated that at the same gas mass flow rate, the noise level from elevated flare stacks are significantly higher than ground flares. tabs., figs.

  3. Prediction and comparison of noise levels from ground and elevated flare systems

    Energy Technology Data Exchange (ETDEWEB)

    Obasi, E. [Stantec Consulting Ltd., Surrey, BC (Canada)

    2009-07-01

    Flaring is a process to dispose of hydrocarbons during clean-up, emergency shut downs or dispose a small volume waste streams of mixed gasses that cannot easily or safely be separated. This presentation discussed flaring as a noise issue. It focused on flaring noise characterization; flare noise modeling; flare sound power levels; and flare sound pressure level comparison at a distance of 1.5 km. The presentation included a photograph of flaring at a gas plant in Nigeria. The presentation listed some of the potential health effects associated with long term exposure to excessive noise, such as hearing loss; headaches; stress; fatigue; sleep disturbance; and high blood pressure. Companies flare gas to dispose waste gases in a safe and reliable manner through combustion and to depressurize gas lines during maintenance and emergencies. This presentation also discussed ground and elevated flares; components of flare noise characterization; and key factors affecting flare noise. A model to predict flaring noise was also presented. It demonstrated that at the same gas mass flow rate, the noise level from elevated flare stacks are significantly higher than ground flares. tabs., figs.

  4. How much noise reduction at airports?

    NARCIS (Netherlands)

    Lijesen, M.G.; van der Straaten, J.W.; Dekkers, J.E.C.; van Elk, R.; Blokdijk, J.

    2010-01-01

    Airport noise nuisance is a negative externality especially when it occurring near urban areas. Like all externalities, noise nuisance may be a reason for government intervention. When intervening, governments should set quantitative policy targets with care. In practice, this issue is generally

  5. Musical noise reduction using an adaptive filter

    Science.gov (United States)

    Hanada, Takeshi; Murakami, Takahiro; Ishida, Yoshihisa; Hoya, Tetsuya

    2003-10-01

    This paper presents a method for reducing a particular noise (musical noise). The musical noise is artificially produced by Spectral Subtraction (SS), which is one of the most conventional methods for speech enhancement. The musical noise is the tin-like sound and annoying in human auditory. We know that the duration of the musical noise is considerably short in comparison with that of speech, and that the frequency components of the musical noise are random and isolated. In the ordinary SS-based methods, the musical noise is removed by the post-processing. However, the output of the ordinary post-processing is delayed since the post-processing uses the succeeding frames. In order to improve this problem, we propose a novel method using an adaptive filter. In the proposed system, the observed noisy signal is used as the input signal to the adaptive filter and the output of SS is used as the reference signal. In this paper we exploit the normalized LMS (Least Mean Square) algorithm for the adaptive filter. Simulation results show that the proposed method has improved the intelligibility of the enhanced speech in comparison with the conventional method.

  6. Acceptable noise level with Danish, Swedish, and non-semantic speech materials

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Lantz, Johannes; Nielsen, Lars Holme

    2012-01-01

    reported results from American studies. Generally, significant differences were seen between test conditions using different types of noise within ears in each population. Significant differences were seen for ANL across populations, also when the non-semantic ISTS was used as speech signal. Conclusions......Abstract Objective: Acceptable noise level (ANL) has been established as a method to quantify the acceptance of background noise while listening to speech presented at the most comfortable level. The aim of the present study was to generate Danish, Swedish, and a non-semantic version of the ANL...... test and investigate normal-hearing Danish and Swedish subjects' performance on these tests. Design: ANL was measured using Danish and Swedish running speech with two different noises: Speech-weighted amplitude-modulated noise, and multitalker speech babble. ANL was also measured using the non...

  7. Noise Optimization in Diesel Engines

    Directory of Open Access Journals (Sweden)

    S. Narayan

    2014-04-01

    Full Text Available Euro 6 norms emphasize on reduction of emissions from the engines. New injection methods are being adopted for homogenous mixture formation in diesel engines. During steady state conditions homogenous combustion gave noise levels in lower frequencies. In this work noise produced in a 440 cc diesel engine has been investigated. The engine was run under various operating conditions varying various injection parameters.

  8. Recent technologies for reduction of aircraft propulsion noise. Kokuki engine soon teigenka no saikin no gijutsu shinpo ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, H [National Aerospace Lab., Chofu, Tokyo (Japan)

    1994-03-10

    Inside the jet engine, the propulsion engine for an aircraft, a high speed air current is flowing, and the rotors such as the fan, compress or, turbine and so forth are rotating with a high speed in its flowing current. The flow itself in which a high speed exhaust jet is discharged in the air from engine exhaust port, and the aerodynamic noise generated by an interaction of the flow with the material bodies are the main noise sources of the aircraft engine. Because the supersonic planes are necessary to fly with mach number 2 - 3 during cruising, the turbojet engine with a large jet exhaust speed or the low bypass ratio turbofan engine is selected. Since a noise reduction by reducing the jet exhaust speed, which was an effective measure for the high subsonic speed passenger plane, can not be applied, a reduction of the supersonic jet noise, which is hard to be reduced, becomes a necessity. In addition, in recent years, a research and development of the advanced turbo prop (ATP) aircraft with a further higher thrust efficiency are advanced as well. The aerodynamical noise reduction technologies of these engines for supersonic airplanes are summarized. 14 refs., 11 figs., 1 tab.

  9. Effects of pedagogical ideology on the perceived loudness and noise levels in preschools.

    Science.gov (United States)

    Jonsdottir, Valdis; Rantala, Leena M; Oskarsson, Gudmundur Kr; Sala, Eeva

    2015-01-01

    High activity noise levels that result in detrimental effects on speech communication have been measured in preschools. To find out if different pedagogical ideologies affect the perceived loudness and levels of noise, a questionnaire study inquiring about the experience of loudness and voice symptoms was carried out in Iceland in eight private preschools, called "Hjalli model", and in six public preschools. Noise levels were also measured in the preschools. Background variables (stress level, age, length of working career, education, smoking, and number of children per teacher) were also analyzed in order to determine how much they contributed toward voice symptoms and the experience of noisiness. Results indicate that pedagogical ideology is a significant factor for predicting noise and its consequences. Teachers in the preschool with tighter pedagogical control of discipline (the "Hjalli model") experienced lower activity noise loudness than teachers in the preschool with a more relaxed control of behavior (public preschool). Lower noise levels were also measured in the "Hjalli model" preschool and fewer "Hjalli model" teachers reported voice symptoms. Public preschool teachers experienced more stress than "Hjalli model" teachers and the stress level was, indeed, the background variable that best explained the voice symptoms and the teacher's perception of a noisy environment. Discipline, structure, and organization in the type of activity predicted the activity noise level better than the number of children in the group. Results indicate that pedagogical ideology is a significant factor for predicting self-reported noise and its consequences.

  10. Evaluation of noise level in architecture department building in University of Sumatera Utara

    Science.gov (United States)

    Amran, Novrial; Damanik, Novita Hillary Christy

    2018-03-01

    Noise is one the comfort factors that need to be noticed, particularly in an educational environment. Hearing a high noise in a period can affect students’ learning performance. The aims of this study were to know the noise level and get an appropriate design to reduce noise in Architecture Department building in the University of Sumatera Utara, considering that architecture students often spend most of their time inside the room. The measurement was conducted in four rooms for two days each from 09:00 – 12:00 and from 13:00 – 16:00 by using Sound Level Meter that placed near the noise source of the room. The result indicated that the average of noise level exceeded the 55 dB(A) so it still needs the appropriate design to reduce the noise that occurs in the building.

  11. 33 CFR 149.697 - What are the requirements for a noise level survey?

    Science.gov (United States)

    2010-07-01

    ... and Equipment Noise Limits § 149.697 What are the requirements for a noise level survey? (a) A survey... measured over 12 hours to derive a time weighted average (TWA) using a sound level meter and an A-weighted filter or equivalent device. (c) If the noise level throughout a space is determined to exceed 85 db(A...

  12. Optimal noise reduction in 3D reconstructions of single particles using a volume-normalized filter

    Science.gov (United States)

    Sindelar, Charles V.; Grigorieff, Nikolaus

    2012-01-01

    The high noise level found in single-particle electron cryo-microscopy (cryo-EM) image data presents a special challenge for three-dimensional (3D) reconstruction of the imaged molecules. The spectral signal-to-noise ratio (SSNR) and related Fourier shell correlation (FSC) functions are commonly used to assess and mitigate the noise-generated error in the reconstruction. Calculation of the SSNR and FSC usually includes the noise in the solvent region surrounding the particle and therefore does not accurately reflect the signal in the particle density itself. Here we show that the SSNR in a reconstructed 3D particle map is linearly proportional to the fractional volume occupied by the particle. Using this relationship, we devise a novel filter (the “single-particle Wiener filter”) to minimize the error in a reconstructed particle map, if the particle volume is known. Moreover, we show how to approximate this filter even when the volume of the particle is not known, by optimizing the signal within a representative interior region of the particle. We show that the new filter improves on previously proposed error-reduction schemes, including the conventional Wiener filter as well as figure-of-merit weighting, and quantify the relationship between all of these methods by theoretical analysis as well as numeric evaluation of both simulated and experimentally collected data. The single-particle Wiener filter is applicable across a broad range of existing 3D reconstruction techniques, but is particularly well suited to the Fourier inversion method, leading to an efficient and accurate implementation. PMID:22613568

  13. Determination of the level of noise in nurseries and pre-schools and the teachers′ level of annoyance

    Directory of Open Access Journals (Sweden)

    Ozan Gokdogan

    2016-01-01

    Full Text Available Objective: The aim of this article is to determine the level of noise in nurseries and pre-schools and also to compare measured levels with standard levels and evaluate the teachers’ level of annoyance. Materials and Methods: The level of noise was measured in three different schools. A total of 162 students, whose ages were between 3 and 6 years, and 12 teachers were included the study. Every age groups’ level of noise was measured during sleeping, gaming, and eating activity. In addition, teachers’ annoyance was assessed in different age groups. Results: The 4- to 6-year-old groups were found to have higher level of sounds than 3-year-old group. Eating period was found to be the highest level of sound whereas sleeping was found the lowest. Furthermore, teachers’ annoyance was found higher as the age decreased. Conclusion: Nurseries and pre-schools have noisy environment both for the students and the teachers. High level of noise, which has bad effects on health, is a public health problem. Both the students’ families and teachers must be aware of this annoying situation.

  14. Can weekly noise levels of urban road traffic, as predominant noise source, estimate annual ones?

    Science.gov (United States)

    Prieto Gajardo, Carlos; Barrigón Morillas, Juan Miguel; Rey Gozalo, Guillermo; Vílchez-Gómez, Rosendo

    2016-11-01

    The effects of noise pollution on human quality of life and health were recognised by the World Health Organisation a long time ago. There is a crucial dilemma for the study of urban noise when one is looking for proven methodologies that can allow, on the one hand, an increase in the quality of predictions, and on the other hand, saving resources in the spatial and temporal sampling. The temporal structure of urban noise is studied in this work from a different point of view. This methodology, based on Fourier analysis, is applied to several measurements of urban noise, mainly from road traffic and one-week long, carried out in two cities located on different continents and with different sociological life styles (Cáceres, Spain and Talca, Chile). Its capacity to predict annual noise levels from weekly measurements is studied. The relation between this methodology and the categorisation method is also analysed.

  15. Fast noise level estimation algorithm based on principal component analysis transform and nonlinear rectification

    Science.gov (United States)

    Xu, Shaoping; Zeng, Xiaoxia; Jiang, Yinnan; Tang, Yiling

    2018-01-01

    We proposed a noniterative principal component analysis (PCA)-based noise level estimation (NLE) algorithm that addresses the problem of estimating the noise level with a two-step scheme. First, we randomly extracted a number of raw patches from a given noisy image and took the smallest eigenvalue of the covariance matrix of the raw patches as the preliminary estimation of the noise level. Next, the final estimation was directly obtained with a nonlinear mapping (rectification) function that was trained on some representative noisy images corrupted with different known noise levels. Compared with the state-of-art NLE algorithms, the experiment results show that the proposed NLE algorithm can reliably infer the noise level and has robust performance over a wide range of image contents and noise levels, showing a good compromise between speed and accuracy in general.

  16. Noise levels from toys and recreational articles for children and teenagers.

    Science.gov (United States)

    Hellstrom, P A; Dengerink, H A; Axelsson, A

    1992-10-01

    This study examined the noise level emitted by toys and recreational articles used by children and teenagers. The results indicate that many of the items tested emit sufficiently intense noise to be a source of noise induced hearing loss in school-age children. While the baby toys provided noise exposure within the limits of national regulations, they are most intense in a frequency range that corresponds to the resonance frequency of the external auditory canal of very young children. Hobby motors emit noise that may require protection depending upon the length of use. Fire-crackers and cap guns emit impulse noises that exceed even conservative standards for noise exposure.

  17. I'm trying to heal...noise levels in a pediatric intensive care unit.

    Science.gov (United States)

    Milette, Isabelle H; Carnevale, Franco A

    2003-01-01

    The literature demonstrates clearly that most intensive care units exceed the standard recommendations for noise levels in hospitals, and that high noise levels have negative impacts on patients and staff. The purpose of this study was to evaluate the level of noise in a PICU and compare it to the recommendations of international bodies. We outline recommendations to promote the awareness of this problem and suggest strategies to decrease the level of noise in a PICU. The orientations of these strategies are threefold: 1) architectural-acoustic design, 2) equipment design and, most importantly, 3) staff education.

  18. The effects of noise reduction by earmuffs on the physiologic and behavioral responses in very low birth weight preterm infants.

    Science.gov (United States)

    Duran, Rıdvan; Ciftdemir, Nükhet Aladağ; Ozbek, Ulfet Vatansever; Berberoğlu, Ufuk; Durankuş, Ferit; Süt, Necdet; Acunaş, Betül

    2012-10-01

    Preterm infants are exposed to loud noises during their stay in the neonatal intensive care unit which can lead to physiologic and behavioral alterations and even hearing loss. The use of earmuffs can reduce sound level and these changes. The objective of the present study is to evaluate the effectiveness of the earmuffs in preterm infants solely cared for in closed incubators. A comparative prospective study comprising 20 clinically stable preterm infants weighing less than 1500 g cared in closed incubator was conducted. Preterm infants acted as their own controls whereby they were observed without earmuffs (Group 1) for 2 days and with earmuffs (Group 2) on consecutive 2 days. The preterm infants' physiologic responses and Anderson Behavioral State Scoring System (ABSS) scores were assessed over 30s every 2h for 8h during daytime for 4 days. Out of 20 preterm infants, 6 were male and 14 female with a mean birth weight of 1220 ± 209 g, gestational age of 29.9 ± 2.1 weeks. The total number of measurements was 320. The mean ABSS scores of Group 1 and 2 were 3.07±1.1 and 1.34 ± 0.3, respectively. Statistically significant difference was noted between the means of ABSS scores (pNoise level reduction was associated with significant improvement in behavioral states of ABSS. We suggest that noise reduction in preterm infants with earmuffs is helpful by improving sleep efficiency and increasing time of quiet sleep. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Lateralization of noise bursts in interaurally correlated or uncorrelated background noise using interaural level differences.

    Science.gov (United States)

    Reed, Darrin K; van de Par, Steven

    2015-10-01

    The interaural level difference (ILD) of a lateralized target source may be effectively reduced when the target is presented together with background noise containing zero ILD. It is not certain whether listeners perceive a position congruent with the reduced ILD or the actual target ILD in a lateralization task. Two sets of behavioral experiments revealed that many listeners perceived a position at or even larger than that corresponding to the presented target ILD when a temporal onset/offset asynchrony between the broadband target and the broadband background noise was present. When no temporal asynchrony was present, however, the perceived lateral position indicated a dependency on the coherence of the background noise for several listeners. With interaurally correlated background noise, listeners reported a reduced ILD resulting from the combined target and background noise stimulus. In contrast, several of the listeners made a reasonable estimate of the position corresponding to the target ILD for interaurally uncorrelated, broadband, background noise. No obvious difference in performance was seen between low- or high-frequency stimuli. Extension of a weighting template to the output of a standard equalization-cancellation model was shown to remove a lateral bias on the predicted target ILD resulting from the presence of background noise. Provided that an appropriate weighting template is applied based on knowledge of the background noise coherence, good prediction of the behavioral data is possible.

  20. Estimating the level of dynamical noise in time series by using fractal dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Sase, Takumi, E-mail: sase@sat.t.u-tokyo.ac.jp [Graduate School of Information Science and Technology, The University of Tokyo, Tokyo 153-8505 (Japan); Ramírez, Jonatán Peña [CONACYT Research Fellow, Center for Scientific Research and Higher Education at Ensenada (CICESE), Carretera Ensenada-Tijuana No. 3918, Zona Playitas, C.P. 22860, Ensenada, Baja California (Mexico); Kitajo, Keiichi [BSI-Toyota Collaboration Center, RIKEN Brain Science Institute, Wako, Saitama 351-0198 (Japan); Aihara, Kazuyuki; Hirata, Yoshito [Graduate School of Information Science and Technology, The University of Tokyo, Tokyo 153-8505 (Japan); Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505 (Japan)

    2016-03-11

    We present a method for estimating the dynamical noise level of a ‘short’ time series even if the dynamical system is unknown. The proposed method estimates the level of dynamical noise by calculating the fractal dimensions of the time series. Additionally, the method is applied to EEG data to demonstrate its possible effectiveness as an indicator of temporal changes in the level of dynamical noise. - Highlights: • A dynamical noise level estimator for time series is proposed. • The estimator does not need any information about the dynamics generating the time series. • The estimator is based on a novel definition of time series dimension (TSD). • It is demonstrated that there exists a monotonic relationship between the • TSD and the level of dynamical noise. • We apply the proposed method to human electroencephalographic data.

  1. Estimating the level of dynamical noise in time series by using fractal dimensions

    International Nuclear Information System (INIS)

    Sase, Takumi; Ramírez, Jonatán Peña; Kitajo, Keiichi; Aihara, Kazuyuki; Hirata, Yoshito

    2016-01-01

    We present a method for estimating the dynamical noise level of a ‘short’ time series even if the dynamical system is unknown. The proposed method estimates the level of dynamical noise by calculating the fractal dimensions of the time series. Additionally, the method is applied to EEG data to demonstrate its possible effectiveness as an indicator of temporal changes in the level of dynamical noise. - Highlights: • A dynamical noise level estimator for time series is proposed. • The estimator does not need any information about the dynamics generating the time series. • The estimator is based on a novel definition of time series dimension (TSD). • It is demonstrated that there exists a monotonic relationship between the • TSD and the level of dynamical noise. • We apply the proposed method to human electroencephalographic data.

  2. Noise pollution in Lahore and the solution

    International Nuclear Information System (INIS)

    Ahmad, K.

    1999-01-01

    The main objective of the study is to know the current status of noise levels in Lahore as compared to NEQS . Sound Level Meter model 211 FS Quest Electronics with a 50-120 dBA selectable range was used in the current investigation. Study relates to road traffic noise, aircraft noise at city airports, rail traffic noise, noise levels in urban centers and occupational noise. Investigation revealed that nine main commercial centers, six public hospital and ten educational institution of Lahore had values higher than NEQS (85 dBA). Maximum noise producing vehicles on Lahore roads are scooter producing a noise of 90, 86 and 87 dBA. There are forty airports in operation in the country and the aircraft being used has higher noise level varying from 16 to 120 dBA. Based on age and length of service permanent hearing damage has been observed in skilled industrial workers. Risk from hearing damage of industrial workers can be reduced by the use of some form of ear protection. Ear plugs can reduce noise levels by 15 to 35 dBA according to their design and fit. Industrial noise from heavy machinery can be reduced by anti-vibration mountings. Noisy work area in industry should be either isolated or surrounded by baffles. The most appealing approach to reduce noise problems in communities due to aircraft operation is reduction of the noise generated by the aircraft and land use planning. (author)

  3. An evaluation of primary school students' views about noise levels in school

    Directory of Open Access Journals (Sweden)

    Nermin Bulunuz

    2017-06-01

    Full Text Available Effective education and teaching requires keeping classroom noise levels within specific limits. The purpose of this study is to evaluate students’ views about the noise level in school, its effects, and control of it at two primary schools (one public school and one private school located in a district of Bursa - within the scope of the TÜBİTAK 1001 project numbered 114K738. The research sample consists of 432 third and fourth graders, 223 of whom are from the public school and 209 of whom are from the private school. To collect data, a 20-question survey was administered to the students, and noise measurements were carried out in the schools. According to the findings obtained from the analysis of the answers from the student questionnaire, the students think that the noise level is high especially during break times. In parallel with the student views, the average noise level at break time during recess was found to be 74.56 dBA at the private primary school and 82.18 dBA at the public primary school. These values are much higher than the limits prescribed in the Regulation on Assessment and Management of Environmental Noise in Turkey (RAMEN European Union Harmonization Laws. The research findings show that this important problem must be dealt with urgently, and substantive efforts and activities must be launched to reduce high noise levels in schools.

  4. Image processing methods for noise reduction in the TJ-II Thomson Scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informatica y Automatica, UNED, Madrid 28040 (Spain); Farias, G. [Pontificia Universidad Catolica de Valparaiso, Valparaiso (Chile); Vega, J.; Pastor, I. [Asociacion EURATOM/CIEMAT para Fusion, Madrid 28040 (Spain)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe an approach in order to reduce or mitigate the stray-light on the images and show the exceptional results. Black-Right-Pointing-Pointer We analyze the parameters to take account in the proposed process. Black-Right-Pointing-Pointer We report a simplified exampled in order to explain the proposed process. - Abstract: The Thomsom Scattering diagnostic of the TJ-II stellarator provides temperature and density profiles. The CCD camera acquires images corrupted with noise that, in some cases, can produce unreliable profiles. The main source of noise is the so-called stray-light. In this paper we describe an approach that allows mitigation of the effects that stray-light has on the images: extraction regions with connected-components. In addition, the robustness and effectiveness of the noise reduction technique is validated in two ways: (1) supervised classification and (2) comparison of electron temperature profiles.

  5. Design of a Low-Power VLSI Macrocell for Nonlinear Adaptive Video Noise Reduction

    Directory of Open Access Journals (Sweden)

    Sergio Saponara

    2004-09-01

    Full Text Available A VLSI macrocell for edge-preserving video noise reduction is proposed in the paper. It is based on a nonlinear rational filter enhanced by a noise estimator for blind and dynamic adaptation of the filtering parameters to the input signal statistics. The VLSI filter features a modular architecture allowing the extension of both mask size and filtering directions. Both spatial and spatiotemporal algorithms are supported. Simulation results with monochrome test videos prove its efficiency for many noise distributions with PSNR improvements up to 3.8 dB with respect to a nonadaptive solution. The VLSI macrocell has been realized in a 0.18 μm CMOS technology using a standard-cells library; it allows for real-time processing of main video formats, up to 30 fps (frames per second 4CIF, with a power consumption in the order of few mW.

  6. Effects of pedagogical ideology on the perceived loudness and noise levels in preschools

    Science.gov (United States)

    Jonsdottir, Valdis; Rantala, Leena M.; Oskarsson, Gudmundur Kr.; Sala, Eeva

    2015-01-01

    High activity noise levels that result in detrimental effects on speech communication have been measured in preschools. To find out if different pedagogical ideologies affect the perceived loudness and levels of noise, a questionnaire study inquiring about the experience of loudness and voice symptoms was carried out in Iceland in eight private preschools, called “Hjalli model”, and in six public preschools. Noise levels were also measured in the preschools. Background variables (stress level, age, length of working career, education, smoking, and number of children per teacher) were also analyzed in order to determine how much they contributed toward voice symptoms and the experience of noisiness. Results indicate that pedagogical ideology is a significant factor for predicting noise and its consequences. Teachers in the preschool with tighter pedagogical control of discipline (the “Hjalli model”) experienced lower activity noise loudness than teachers in the preschool with a more relaxed control of behavior (public preschool). Lower noise levels were also measured in the “Hjalli model” preschool and fewer “Hjalli model” teachers reported voice symptoms. Public preschool teachers experienced more stress than “Hjalli model” teachers and the stress level was, indeed, the background variable that best explained the voice symptoms and the teacher's perception of a noisy environment. Discipline, structure, and organization in the type of activity predicted the activity noise level better than the number of children in the group. Results indicate that pedagogical ideology is a significant factor for predicting self-reported noise and its consequences. PMID:26356370

  7. Subspace-Based Noise Reduction for Speech Signals via Diagonal and Triangular Matrix Decompositions

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Søren Holdt

    We survey the definitions and use of rank-revealing matrix decompositions in single-channel noise reduction algorithms for speech signals. Our algorithms are based on the rank-reduction paradigm and, in particular, signal subspace techniques. The focus is on practical working algorithms, using both...... diagonal (eigenvalue and singular value) decompositions and rank-revealing triangular decompositions (ULV, URV, VSV, ULLV and ULLIV). In addition we show how the subspace-based algorithms can be evaluated and compared by means of simple FIR filter interpretations. The algorithms are illustrated...... with working Matlab code and applications in speech processing....

  8. The influence of road traffic noise on sleep

    Science.gov (United States)

    Eberhardt, J. L.

    1988-12-01

    The influence of road traffic noise on the sleep of adults and 6-11 year old children was studied by using electrophysiological methods. Young adults, unaccustomed to traffic noise, were disturbed by continuous and intermittent traffic noise at 45 dB(A). No sleep disturbances were found for continuous traffic noise at 36 dB(A). Car passages with a peak noise level of 55 dB(A) caused awakenings. The equivalent sound pressure level ( Leq) did not correlate with sleep disturbance effects. A better noise dose description was found in the number of vehicles per night that made most noise. Children wer about 10 dB(A) less sensitive than adults to awakening reactions, and even less sensitive with respect to disturbances of REM sleep and deep sleep. Total habituation to road traffic noise did not occur, even after at least one year of exposure. Sound reduction in the bedroom induced increased amounts of deep sleep for adults and reduced falling-asleep time for children. Road traffic noise during the first hours of a night's sleep tended to disturb sleep more than when it ocurred later in the night, the main effects being a reduction of the total amount of REM sleep during the night and an increased duration of intermittent wakefulness during the hours of exposure.

  9. Sea-Level Trend Uncertainty With Pacific Climatic Variability and Temporally-Correlated Noise

    Science.gov (United States)

    Royston, Sam; Watson, Christopher S.; Legrésy, Benoît; King, Matt A.; Church, John A.; Bos, Machiel S.

    2018-03-01

    Recent studies have identified climatic drivers of the east-west see-saw of Pacific Ocean satellite altimetry era sea level trends and a number of sea-level trend and acceleration assessments attempt to account for this. We investigate the effect of Pacific climate variability, together with temporally-correlated noise, on linear trend error estimates and determine new time-of-emergence (ToE) estimates across the Indian and Pacific Oceans. Sea-level trend studies often advocate the use of auto-regressive (AR) noise models to adequately assess formal uncertainties, yet sea level often exhibits colored but non-AR(1) noise. Standard error estimates are over- or under-estimated by an AR(1) model for much of the Indo-Pacific sea level. Allowing for PDO and ENSO variability in the trend estimate only reduces standard errors across the tropics and we find noise characteristics are largely unaffected. Of importance for trend and acceleration detection studies, formal error estimates remain on average up to 1.6 times those from an AR(1) model for long-duration tide gauge data. There is an even chance that the observed trend from the satellite altimetry era exceeds the noise in patches of the tropical Pacific and Indian Oceans and the south-west and north-east Pacific gyres. By including climate indices in the trend analysis, the time it takes for the observed linear sea-level trend to emerge from the noise reduces by up to 2 decades.

  10. Seismic noise level variation in South Korea

    Science.gov (United States)

    Sheen, D.; Shin, J.

    2008-12-01

    The variations of seismic background noise in South Korea have been investigated by means of power spectral analysis. The Korea Institute of Geoscience and Mineral Resources (KIGAM) and the Korea Meteorological Administation (KMA) have national wide seismic networks in South Korea, and, in the end of 2007, there are 30 broadband stations which have been operating for more than a year. In this study, we have estimated the power spectral density of seismic noise for 30 broadband stations from 2005 to 2007. Since we estimate PSDs from a large dataset of continuous waveform in this study, a robust PSD estimate of McNamara and Buland (2004) is used. In the frequency range 1-5 Hz, the diurnal variations of noise are observed at most of stations, which are especially larger at coastal stations and at insular than at inland. Some stations shows daily difference of diurnal variations, which represents that cultural activities contribute to the noise level of a station. The variation of number of triggered stations, however, shows that cultural noise has little influence on the detection capability of seismic network in South Korea. Seasonal variations are observed well in the range 0.1-0.5 Hz, while much less found in the frequency range 1-5 Hz. We observed that strong peaks in the range 0.1-0.5 Hz occur at the summer when Pacific typhoons are close to the Korean Peninsula.

  11. Application of the fourier and wavelet transforms in noise reduction of the out of the ordinary data

    International Nuclear Information System (INIS)

    Tafreshi, M. A.; Sadeghi, Y.

    2006-01-01

    In this article the noise reduction of the experimental data by the Fourier and the wavelet transforms has been investigated. Using both simulated and experimental data (from the plasma focus facility, Dena), the sensitive features of the application of the Fourier transform are visualized and discussed. Then, the main idea of the wavelet transform and the results of the noise reduction with this transform are presented. Due to this investigation, for the cases such as the current derivative of the Dena facility, where the reliability of the Fourier transform can be doubtful, the wavelet transform can be considered as a more accurate alternative approach

  12. Noise characterization of oil and gas operations.

    Science.gov (United States)

    Radtke, Cameron; Autenrieth, Daniel A; Lipsey, Tiffany; Brazile, William J

    2017-08-01

    , hydraulic fracturing, and completion sites exceeded 65 dBC.  Current noise wall mitigation strategies reduced noise levels in both the A- and C-weighted scale measurements. However, this reduction in noise was not sufficient to reduce the noise below the residential permissible noise level (55 dBA).

  13. Wake Management Strategies for Reduction of Turbomachinery Fan Noise

    Science.gov (United States)

    Waitz, Ian A.

    1998-01-01

    The primary objective of our work was to evaluate and test several wake management schemes for the reduction of turbomachinery fan noise. Throughout the course of this work we relied on several tools. These include 1) Two-dimensional steady boundary-layer and wake analyses using MISES (a thin-shear layer Navier-Stokes code), 2) Two-dimensional unsteady wake-stator interaction simulations using UNSFLO, 3) Three-dimensional, steady Navier-Stokes rotor simulations using NEWT, 4) Internal blade passage design using quasi-one-dimensional passage flow models developed at MIT, 5) Acoustic modeling using LINSUB, 6) Acoustic modeling using VO72, 7) Experiments in a low-speed cascade wind-tunnel, and 8) ADP fan rig tests in the MIT Blowdown Compressor.

  14. Measurements and Predictions of the Noise from Three-Stream Jets

    Science.gov (United States)

    Henderson, Brenda S.; Leib, Stewart J.; Wernet, Mark P.

    2015-01-01

    An experimental and numerical investigation of the noise produced by high-subsonic and supersonic three-stream jets was conducted. The exhaust system consisted of externally-mixed-convergent nozzles and an external plug. Bypass- and tertiary-to-core area ratios between 1.0 and 2.5, and 0.4 and 1.0, respectively, were studied. Axisymmetric and offset tertiary nozzles were investigated for heated and unheated conditions. For axisymmetric configurations, the addition of the third stream was found to reduce peak- and high-frequency acoustic levels in the peak-jet-noise direction, with greater reductions at the lower bypass-to-core area ratios. For the offset configurations, an offset duct was found to decrease acoustic levels on the thick side of the tertiary nozzle relative to those produced by the simulated two-stream jet with up to 8 dB mid-frequency noise reduction at large angles to the jet inlet axis. Noise reduction in the peak-jet-noise direction was greater for supersonic core speeds than for subsonic core speeds. The addition of a tertiary nozzle insert used to divert the third-stream jet to one side of the nozzle system provided no noise reduction. Noise predictions are presented for selected cases using a method based on an acoustic analogy with mean flow interaction effects accounted for using a Green's function, computed in terms of its coupled azimuthal modes for the offset cases, and a source model previously used for round and rectangular jets. Comparisons of the prediction results with data show that the noise model predicts the observed increase in low-frequency noise with the introduction of a third, axisymmetric stream, but not the high-frequency reduction. For an offset third stream, the model predicts the observed trend of decreased sound levels on the thick side of the jet compared with the thin side, but the predicted azimuthal variations are much less than those seen in the data. Also, the shift of the spectral peak to lower frequencies with

  15. Optimal filter design for shielded and unshielded ambient noise reduction in fetal magnetocardiography

    International Nuclear Information System (INIS)

    Comani, S; Mantini, D; Alleva, G; Luzio, S Di; Romani, G L

    2005-01-01

    The greatest impediment to extracting high-quality fetal signals from fetal magnetocardiography (fMCG) is environmental magnetic noise, which may have peak-to-peak intensity comparable to fetal QRS amplitude. Being an unstructured Gaussian signal with large disturbances at specific frequencies, ambient field noise can be reduced with hardware-based approaches and/or with software algorithms that digitally filter magnetocardiographic recordings. At present, no systematic evaluation of filters' performances on shielded and unshielded fMCG is available. We designed high-pass and low-pass Chebychev II-type filters with zero-phase and stable impulse response; the most commonly used band-pass filters were implemented combining high-pass and low-pass filters. The achieved ambient noise reduction in shielded and unshielded recordings was quantified, and the corresponding signal-to-noise ratio (SNR) and signal-to-distortion ratio (SDR) of the retrieved fetal signals was evaluated. The study regarded 66 fMCG datasets at different gestational ages (22-37 weeks). Since the spectral structures of shielded and unshielded magnetic noise were very similar, we concluded that the same filter setting might be applied to both conditions. Band-pass filters (1.0-100 Hz) and (2.0-100 Hz) provided the best combinations of fetal signal detection rates, SNR and SDR; however, the former should be preferred in the case of arrhythmic fetuses, which might present spectral components below 2 Hz

  16. Projected contributions of future wind farm development to community noise and annoyance levels in Ontario, Canada

    International Nuclear Information System (INIS)

    Whitfield Aslund, Melissa L.; Ollson, Christopher A.; Knopper, Loren D.

    2013-01-01

    Wind turbines produce sound during their operation; therefore, jurisdictions around the world have developed regulations regarding the placement of electricity generating wind farms with the intent of preventing unacceptable levels of ‘community noise’ in their vicinity. However, as survey results indicate that the relationship between wind turbine noise and annoyance may differ from noise-annoyance relationships for other common noise sources (e.g., rail, traffic), there are concerns that the application of general noise guidelines for wind turbines may lead to unacceptably high levels of annoyance in communities. In this study, previously published survey results that quantified wind turbine noise and self-reported annoyance were applied to the predicted noise levels (from turbines and transformers) for over 8000 receptors in the vicinity of 13 planned wind power developments in the province of Ontario, Canada. The results of this analysis indicate that the current wind turbine noise restrictions in Ontario will limit community exposure to wind turbine related noise such that levels of annoyance are unlikely to exceed previously established background levels of noise-related annoyance from other common noise sources. This provides valuable context that should be considered by policy-makers when evaluating the potential impacts of wind turbine noise on the community. -- highlights: •Wind turbine noise-annoyance relationship used to predict annoyance in Ontario. •Noise annoyance predicted to be <8% for non-participants <1 km from turbines. •Predicted levels of wind turbine noise annoyance similar to that from traffic noise. •Wind turbine noise annoyance not expected to exceed existing background levels

  17. Measurement and control of occupational noise

    International Nuclear Information System (INIS)

    Elammari, Muftah Faraj

    2007-01-01

    High level of environmental and occupational noise remain a problem all over the world. As problems and complaints increased dramatically by the end of the 19th and beginning of the 20th centuries focusing on the problem was intensified. In this thesis occupational noise levels at different places were measured and compared with the international permissible levels using the integrating sound level meter (Quest 2800). The calibration of the instrument was carried out before and after each measurement using the acoustic calibrator (Quest CA-12B calibrator). The method which was followed was measuring the sound pressure level of the different noise sources over a broad frequency band covering the audible frequency range using the (octave band filter, model OB-100), disregrading variation with time. Since the human ear is most sensitive in the 2-5 khz range of frequencies and least sensitive at extremely high and low frequencies the instrument was adjusted on the A weighting net work which varies with frequencies in a very similar way as that of the human ear. From the obtained results, some noise levels which were recorded were within the permissible levels i.e. below 90 dba and some noise levels were higher than the permissible limit as in janzour textile factory (95 dba), The welding workshop (120 dba), Benghazi Macaroni factory (100 dba), and near the air blowers at Zletin cement factory, Benghazi cement factory (97-10-dba) in these cases suggestions were made to minimize the problem. Concerning the noise control, four methods of noise control were tested, these methods were: reducing noise by sound absorbing material at Sirt local broadcasting radio, reducing noise by keeping a distance from the noise source, at the Boilers hall at REWDC, reducing noise by enclosures, at the compressors room at Zletin cement factory, and finally reducing noise by performing regular maintenance at Garabolli photo development centre. The percentage of noise reduction was 21%, 12

  18. Reward Pays the Cost of Noise Reduction in Motor and Cognitive Control.

    Science.gov (United States)

    Manohar, Sanjay G; Chong, Trevor T-J; Apps, Matthew A J; Batla, Amit; Stamelou, Maria; Jarman, Paul R; Bhatia, Kailash P; Husain, Masud

    2015-06-29

    Speed-accuracy trade-off is an intensively studied law governing almost all behavioral tasks across species. Here we show that motivation by reward breaks this law, by simultaneously invigorating movement and improving response precision. We devised a model to explain this paradoxical effect of reward by considering a new factor: the cost of control. Exerting control to improve response precision might itself come at a cost--a cost to attenuate a proportion of intrinsic neural noise. Applying a noise-reduction cost to optimal motor control predicted that reward can increase both velocity and accuracy. Similarly, application to decision-making predicted that reward reduces reaction times and errors in cognitive control. We used a novel saccadic distraction task to quantify the speed and accuracy of both movements and decisions under varying reward. Both faster speeds and smaller errors were observed with higher incentives, with the results best fitted by a model including a precision cost. Recent theories consider dopamine to be a key neuromodulator in mediating motivational effects of reward. We therefore examined how Parkinson's disease (PD), a condition associated with dopamine depletion, alters the effects of reward. Individuals with PD showed reduced reward sensitivity in their speed and accuracy, consistent in our model with higher noise-control costs. Including a cost of control over noise explains how reward may allow apparent performance limits to be surpassed. On this view, the pattern of reduced reward sensitivity in PD patients can specifically be accounted for by a higher cost for controlling noise. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Evaluation of noise level at intensive care units in selected hospitals of Sanandaj

    Directory of Open Access Journals (Sweden)

    Nammam Ali Azadi

    2015-08-01

    Conclusion: We found the noise levels were always above the EPA thresholds at all three hospitals both during the day and night. It is recommended to train hospital officials and staffs for keeping noise levels to an acceptable level.

  20. Modeling signal-to-noise ratio of otoacoustic emissions in workers exposed to different industrial noise levels

    Directory of Open Access Journals (Sweden)

    Parvin Nassiri

    2016-01-01

    Full Text Available Introduction: Noise is considered as the most common cause of harmful physical effects in the workplace. A sound that is generated from within the inner ear is known as an otoacoustic emission (OAE. Distortion-product otoacoustic emissions (DPOAEs assess evoked emission and hearing capacity. The aim of this study was to assess the signal-to-noise ratio in different frequencies and at different times of the shift work in workers exposed to various levels of noise. It was also aimed to provide a statistical model for signal-to-noise ratio (SNR of OAEs in different frequencies based on the two variables of sound pressure level (SPL and exposure time. Materials and Methods: This case–control study was conducted on 45 workers during autumn 2014. The workers were divided into three groups based on the level of noise exposure. The SNR was measured in frequencies of 1000, 2000, 3000, 4000, and 6000 Hz in both ears, and in three different time intervals during the shift work. According to the inclusion criterion, SNR of 6 dB or greater was included in the study. The analysis was performed using repeated measurements of analysis of variance, spearman correlation coefficient, and paired samples t-test. Results: The results showed that there was no statistically significant difference between the three exposed groups in terms of the mean values of SNR (P > 0.05. Only in signal pressure levels of 88 dBA with an interval time of 10:30–11:00 AM, there was a statistically significant difference between the right and left ears with the mean SNR values of 3000 frequency (P = 0.038. The SPL had a significant effect on the SNR in both the right and left ears (P = 0.023, P = 0.041. The effect of the duration of measurement on the SNR was statistically significant in both the right and left ears (P = 0.027, P < 0.001. Conclusion: The findings of this study demonstrated that after noise exposure during the shift, SNR of OAEs reduced from the

  1. Ambient Noise Levels in Acute Neonatal Intensive Care Unit of a Tertiary Referral Hospital

    Directory of Open Access Journals (Sweden)

    Sonia R. B D'Souza

    2017-10-01

    Full Text Available Background: Advances in neonatal care have resulted in improved survival of neonates admitted to the intensive care of the Neonatal Intensive Care Unit (NICU. However, the NCU may be an inappropriate milieu, with presence of overwhelming stimuli, most potent being the continuous presence of noise in the ambience of the NICU. Aim and Objectives: To determine and describe the ambient noise levels in the acute NICU of a tertiary referral hospital. Material and Methods: The ambient noise, in this study was the background sound existing in the environment of the acute NICU of a tertiary referral hospital in South India. The ambient noise levels were analyzed by an audiologist and acoustical engineer using a standardized and calibrated Sound Level Meter (SLM i.e., the Hand Held Analyzer type 2250, Brüel and Kjær, Denmark on a weighted frequency A and reported as dB (A. Results: The ambient noise levels were timed measurements yielded by the SLM in terms of L eq, L as well as L exceeded the standard A 10 Aeqmax levels (Leq< 45 dB, L ≤ 50 dB, and Lmax ≤ 65 10 dB.The L eq ranged from 59.4 to 62.12 dB A. A Ventilators with alarms caused the maximum amount of ambient noise yielding a L Sound Pressure Level AF (SPL of 82.14 dB A. Conclusion: The study has found high levels of ambient noise in the acute NICU. Though there are several measures to reduce the ambient noise levels in the NICU, it is essential to raise awareness among health care personnel regarding the observed ambient noise levels and its effects on neonates admitted to the NICU.

  2. Community noise

    Science.gov (United States)

    Bragdon, C. R.

    Airport and community land use planning as they relate to airport noise reduction are discussed. Legislation, community relations, and the physiological effect of airport noise are considered. Noise at the Logan, Los Angeles, and Minneapolis/St. Paul airports is discussed.

  3. Impact of SNR, masker type and noise reduction processing on sentence recognition performance and listening effort as indicated by the pupil dilation response

    DEFF Research Database (Denmark)

    Ohlenforst, Barbara; Wendt, Dorothea; Kramer, Sophia E

    2018-01-01

    Recent studies have shown that activating the noise reduction scheme in hearing aids results in a smaller peak pupil dilation (PPD), indicating reduced listening effort, at 50% and 95% correct sentence recognition with a 4-talker masker. The objective of this study was to measure the effect...... of the noise reduction scheme (on or off) on PPD and sentence recognition across a wide range of signal-to-noise ratios (SNRs) from +16 dB to -12 dB and two masker types (4-talker and stationary noise). Relatively low PPDs were observed at very low (-12 dB) and very high (+16 dB to +8 dB) SNRs presumably due...... to 'giving up' and 'easy listening', respectively. The maximum PPD was observed with SNRs at approximately 50% correct sentence recognition. Sentence recognition with both masker types was significantly improved by the noise reduction scheme, which corresponds to the shift in performance from SNR function...

  4. Evaluating noise abatement measures using strategic noise maps

    NARCIS (Netherlands)

    Borst, H.C.; Miedema, H.M.E.; Laan, W.P.N. van der; Lohman, W.J.A.

    2006-01-01

    Noise annoyance due to transportation is widespread in industrialized countries and in urban areas in the developing countries. The European Noise Directive (END) requires an assessment of the noise situation as well as the formulation of action plans for the reduction of the number of people

  5. Measuring the background acoustic noise in the BN-600 steam generator

    International Nuclear Information System (INIS)

    Yugaj, V.S.; Zhukovets, V.N.; Ivannikov, V.I.; Vylomov, V.V.; Ryabinin, F.; Chernykh, P.G.; Flejsher, Yu.V.

    1987-01-01

    Acoustic noises in the lower chambers of evaporation and intermediate overheating moduli of the BN-600 reactor steam generator are measured. Bachground noises are registered in the whole range of frequencies studied, from 0.63 to 160 kHz. The comparison of noise spectra in evaporator and overheater has revealed a certain difference. However the general tendency is the reduction of the noise level at high frequencies > 8 kHz. The increase of the noise level at low steam content is observed only in a narrow of frequency range of 3-6 kHz

  6. Novel noise reduction filter for improving visibility of early computed tomography signs of hyperacute stroke. Evaluation of the filter's performance. Preliminary clinical experience

    International Nuclear Information System (INIS)

    Takahashi, Noriyuki; Ishii, Kiyoshi; Lee, Y.; Tsai, D.Y.

    2007-01-01

    The aim of this study was to evaluate the performance of a novel noise reduction filter for improving the visibility of early computed tomography (CT) signs of hyperacute stroke on nonenhanced CT images. Fourteen patients with a middle cerebral artery occlusion within 4.5 h after onset were evaluated. The signal-to-noise ratio (SNR) of the processed images with the noise reduction filter and that of original images were measured. Two neuroradiologists visually rated all the processed and original images on the visibility of normal and abnormal gray-white matter interfaces. The SNR value of the processed images was approximately eight times as high as that of the original images, and a 87% reduction of noise was achieved using this technique. For the visual assessment, the results showed that the visibility of normal gray-white matter interface and that of the loss of the gray-white matter interface were significantly improved using the proposed method (P<0.05). The noise reduction filter proposed in the present study has the potential to improve the visibility of early CT signs of hyperacute stroke on nonenhanced CT images. (author)

  7. Simulation of dose reduction in tomosynthesis

    International Nuclear Information System (INIS)

    Svalkvist, Angelica; Baath, Magnus

    2010-01-01

    Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose

  8. Measuring and Assessment the Noise Level in Different Regions in Baghdad City And Compare it with The Allowable Levels

    Directory of Open Access Journals (Sweden)

    Ibtihaj Abdulwahhab Abdulrazzak

    2017-05-01

    Full Text Available This study includes measurement of the noise level of four regions in the city of Baghdad (industrial region, commercial region, residential region and quiet region and compare the value of noise in each region with the World Health Organization (WHO allowable limits, and the effect of noise on human health was explained. The "sound level meter (SLM" instrument measuring the noise value in the four regions, three measurement per month through one year was recorded (one measurement every ten days from 1/1/2015 to 30/12/2015. The noise level of the industrial region (75dB compared with the World Health Organization level allowable limit (65dB, while the commercial region (76.28dB versus (55dB and the residential region (74.94dB versus (50dB and the quiet region was (62.36dB versus (40dB of the (WHO allowable limit.

  9. Measurement of Acceptable Noise Level with Background Music.

    Science.gov (United States)

    Ahn, Hyun-Jung; Bahng, Junghwa; Lee, Jae Hee

    2015-09-01

    Acceptable noise level (ANL) is a measure of the maximum background noise level (BNL) that a person is willing to tolerate while following a target story. Although researchers have used various sources of target sound in ANL measures, a limited type of background noise has been used. Extending the previous study of Gordon-Hickey & Moore (2007), the current study determined the effect of music genre and tempo on ANLs as possible factors affecting ANLs. We also investigated the relationships between individual ANLs and the familiarity of music samples and between music ANLs and subjective preference. Forty-one participants were seperated into two groups according to their ANLs, 29 low-ANL listeners and 12 high-ANL listeners. Using Korean ANL material, the individual ANLs were measured based on the listeners' most comfortable listening level and BNL. The ANLs were measured in six conditions, with different music tempo (fast, slow) and genre (K-pop, pop, classical) in a counterbalanced order. Overall, ANLs did not differ by the tempo of background music, but music genre significantly affected individual ANLs. We observed relatively higher ANLs with K-pop music and relatively lower ANLs with classical music. This tendency was similar in both low-ANL and high-ANL groups. However, the subjective ratings of music familiarity and preference affected ANLs differently for low-ANL and high-ANL groups. In contrast to the low-ANL listeners, the ANLs of the high-ANL listeners were significantly affected by music familiarity and preference. The genre of background music affected ANLs obtained using background music. The degree of music familiarity and preference appears to be associated with individual susceptibility to background music only for listeners who are greatly annoyed by background noise (high-ANL listeners).

  10. Reduction of background noise induced by wind tunnel jet exit vanes

    Science.gov (United States)

    Martin, R. M.; Brooks, T. F.; Hoad, D. R.

    1985-01-01

    The NASA-Langley 4 x 7 m wind tunnel develops low frequency flow pulsations at certain velocity ranges during open throat mode operation, affecting the aerodynamics of the flow and degrading the resulting model test data. Triangular vanes attached to the trailing edge of flat steel rails, mounted 10 cm from the inside of the jet exit walls, have been used to reduce this effect; attention is presently given to methods used to reduce the inherent noise generation of the vanes while retaining their pulsation reduction features.

  11. Poisson-Gaussian Noise Reduction Using the Hidden Markov Model in Contourlet Domain for Fluorescence Microscopy Images

    Science.gov (United States)

    Yang, Sejung; Lee, Byung-Uk

    2015-01-01

    In certain image acquisitions processes, like in fluorescence microscopy or astronomy, only a limited number of photons can be collected due to various physical constraints. The resulting images suffer from signal dependent noise, which can be modeled as a Poisson distribution, and a low signal-to-noise ratio. However, the majority of research on noise reduction algorithms focuses on signal independent Gaussian noise. In this paper, we model noise as a combination of Poisson and Gaussian probability distributions to construct a more accurate model and adopt the contourlet transform which provides a sparse representation of the directional components in images. We also apply hidden Markov models with a framework that neatly describes the spatial and interscale dependencies which are the properties of transformation coefficients of natural images. In this paper, an effective denoising algorithm for Poisson-Gaussian noise is proposed using the contourlet transform, hidden Markov models and noise estimation in the transform domain. We supplement the algorithm by cycle spinning and Wiener filtering for further improvements. We finally show experimental results with simulations and fluorescence microscopy images which demonstrate the improved performance of the proposed approach. PMID:26352138

  12. Active noise control in a duct to cancel broadband noise

    Science.gov (United States)

    Chen, Kuan-Chun; Chang, Cheng-Yuan; Kuo, Sen M.

    2017-09-01

    The paper presents cancelling duct noises by using the active noise control (ANC) techniques. We use the single channel feed forward algorithm with feedback neutralization to realize ANC. Several kinds of ducts noises including tonal noises, sweep tonal signals, and white noise had investigated. Experimental results show that the proposed ANC system can cancel these noises in a PVC duct very well. The noise reduction of white noise can be up to 20 dB.

  13. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    DEFF Research Database (Denmark)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12...... complements the existing model presented by Pelegrín-García, Smits, Brunskog, and Jeong (2011) and expands on it by taking into account the effects of occlusion and background noise level on changes in speech sound level. Conclusions: Three models of the relationship between vocal effort, background noise...

  14. Flap Side Edge Liners for Airframe Noise Reduction

    Science.gov (United States)

    Jones, Michael G. (Inventor); Khorrami, Mehdi R. (Inventor); Choudhari, Meelan M. (Inventor); Howerton, Brian M. (Inventor)

    2014-01-01

    One or more acoustic liners comprising internal chambers or passageways that absorb energy from a noise source on the aircraft are disclosed. The acoustic liners may be positioned at the ends of flaps of an aircraft wing to provide broadband noise absorption and/or dampen the noise producing unsteady flow features, and to reduce the amount of noise generated due to unsteady flow at the inboard and/or outboard end edges of a flap.

  15. Noise reduction in a Mach 5 wind tunnel with a rectangular rod-wall sound shield

    Science.gov (United States)

    Creel, T. R., Jr.; Keyes, J. W.; Beckwith, I. E.

    1980-01-01

    A rod wall sound shield was tested over a range of Reynolds numbers of 0.5 x 10 to the 7th power to 8.0 x 10 to the 7th power per meter. The model consisted of a rectangular array of longitudinal rods with boundary-layer suction through gaps between the rods. Suitable measurement techniques were used to determine properties of the flow and acoustic disturbance in the shield and transition in the rod boundary layers. Measurements indicated that for a Reynolds number of 1.5 x 10 to the 9th power the noise in the shielded region was significantly reduced, but only when the flow is mostly laminar on the rods. Actual nozzle input noise measured on the nozzle centerline before reflection at the shield walls was attenuated only slightly even when the rod boundary layer were laminar. At a lower Reynolds number, nozzle input noise at noise levels in the shield were still too high for application to a quiet tunnel. At Reynolds numbers above 2.0 x 10 the the 7th power per meter, measured noise levels were generally higher than nozzle input levels, probably due to transition in the rod boundary layers. The small attenuation of nozzle input noise at intermediate Reynolds numbers for laminar rod layers at the acoustic origins is apparently due to high frequencies of noise.

  16. The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT

    International Nuclear Information System (INIS)

    Paul, N S; Prezelj, E; Burey, P; Menezes, R J; Blobel, J; Ursani, A; Kashani, H; Siewerdsen, J H

    2010-01-01

    Increased pixel noise and streak artifact reduce CT image quality and limit the potential for radiation dose reduction during CT of the thoracic inlet. We propose to quantify the pixel noise of mediastinal structures in the thoracic inlet, during low-dose (LDCT) and ultralow-dose (uLDCT) thoracic CT, and assess the utility of new software (quantum denoising system and BOOST3D) in addressing these limitations. Twelve patients had LDCT (120 kV, 25 mAs) and uLDCT (120 kV, 10 mAs) images reconstructed initially using standard mediastinal and lung filters followed by the quantum denoising system (QDS) to reduce pixel noise and BOOST3D (B3D) software to correct photon starvation noise as follows: group 1 no QDS, no B3D; group 2 B3D alone; group 3 QDS alone and group 4 both QDS and B3D. Nine regions of interest (ROIs) were replicated on mediastinal anatomy in the thoracic inlet, for each patient resulting in 3456 data points to calculate pixel noise and attenuation. QDS reduced pixel noise by 18.4% (lung images) and 15.8% (mediastinal images) at 25 mAs. B3D reduced pixel noise by ∼8% in the posterior thorax and in combination there was a 35.5% reduction in effective radiation dose (E) for LDCT (1.63-1.05 mSv) in lung images and 32.2% (1.55-1.05 mSv) in mediastinal images. The same combination produced 20.7% reduction (0.53-0.42 mSv) in E for uLDCT, for lung images and 17.3% (0.51-0.42) for mediastinal images. This quantitative analysis of image quality confirms the utility of dedicated processing software in targeting image noise and streak artifact in thoracic LDCT and uLDCT images taken in the thoracic inlet. This processing software potentiates substantial reductions in radiation dose during thoracic LDCT and uLDCT.

  17. The effect of hearing aid signal-processing schemes on acceptable noise levels: perception and prediction.

    Science.gov (United States)

    Wu, Yu-Hsiang; Stangl, Elizabeth

    2013-01-01

    The acceptable noise level (ANL) test determines the maximum noise level that an individual is willing to accept while listening to speech. The first objective of the present study was to systematically investigate the effect of wide dynamic range compression processing (WDRC), and its combined effect with digital noise reduction (DNR) and directional processing (DIR), on ANL. Because ANL represents the lowest signal-to-noise ratio (SNR) that a listener is willing to accept, the second objective was to examine whether the hearing aid output SNR could predict aided ANL across different combinations of hearing aid signal-processing schemes. Twenty-five adults with sensorineural hearing loss participated in the study. ANL was measured monaurally in two unaided and seven aided conditions, in which the status of the hearing aid processing schemes (enabled or disabled) and the location of noise (front or rear) were manipulated. The hearing aid output SNR was measured for each listener in each condition using a phase-inversion technique. The aided ANL was predicted by unaided ANL and hearing aid output SNR, under the assumption that the lowest acceptable SNR at the listener's eardrum is a constant across different ANL test conditions. Study results revealed that, on average, WDRC increased (worsened) ANL by 1.5 dB, while DNR and DIR decreased (improved) ANL by 1.1 and 2.8 dB, respectively. Because the effects of WDRC and DNR on ANL were opposite in direction but similar in magnitude, the ANL of linear/DNR-off was not significantly different from that of WDRC/DNR-on. The results further indicated that the pattern of ANL change across different aided conditions was consistent with the pattern of hearing aid output SNR change created by processing schemes. Compared with linear processing, WDRC creates a noisier sound image and makes listeners less willing to accept noise. However, this negative effect on noise acceptance can be offset by DNR, regardless of microphone mode

  18. Reduction of Air Pollution Levels Downwind of a Road with an Upwind Noise Barrier

    Science.gov (United States)

    We propose a dispersion model to characterize the impact of an upwind solid noise barrier next to a highway on air pollution concentrations downwind of the road. The model is based on data from wind tunnel experiments conducted by Heist et al. (2009). The model assumes that the...

  19. The correlation study of parallel feature extractor and noise reduction approaches

    Energy Technology Data Exchange (ETDEWEB)

    Dewi, Deshinta Arrova; Sundararajan, Elankovan; Prabuwono, Anton Satria [Industrial Computing Research Group, Centre for Artificial Intelligence Technology, Universiti Kebangsaan Malaysia, 43600 Bangi (Malaysia)

    2015-05-15

    This paper presents literature reviews that show variety of techniques to develop parallel feature extractor and finding its correlation with noise reduction approaches for low light intensity images. Low light intensity images are normally displayed as darker images and low contrast. Without proper handling techniques, those images regularly become evidences of misperception of objects and textures, the incapability to section them. The visual illusions regularly clues to disorientation, user fatigue, poor detection and classification performance of humans and computer algorithms. Noise reduction approaches (NR) therefore is an essential step for other image processing steps such as edge detection, image segmentation, image compression, etc. Parallel Feature Extractor (PFE) meant to capture visual contents of images involves partitioning images into segments, detecting image overlaps if any, and controlling distributed and redistributed segments to extract the features. Working on low light intensity images make the PFE face challenges and closely depend on the quality of its pre-processing steps. Some papers have suggested many well established NR as well as PFE strategies however only few resources have suggested or mentioned the correlation between them. This paper reviews best approaches of the NR and the PFE with detailed explanation on the suggested correlation. This finding may suggest relevant strategies of the PFE development. With the help of knowledge based reasoning, computational approaches and algorithms, we present the correlation study between the NR and the PFE that can be useful for the development and enhancement of other existing PFE.

  20. The correlation study of parallel feature extractor and noise reduction approaches

    International Nuclear Information System (INIS)

    Dewi, Deshinta Arrova; Sundararajan, Elankovan; Prabuwono, Anton Satria

    2015-01-01

    This paper presents literature reviews that show variety of techniques to develop parallel feature extractor and finding its correlation with noise reduction approaches for low light intensity images. Low light intensity images are normally displayed as darker images and low contrast. Without proper handling techniques, those images regularly become evidences of misperception of objects and textures, the incapability to section them. The visual illusions regularly clues to disorientation, user fatigue, poor detection and classification performance of humans and computer algorithms. Noise reduction approaches (NR) therefore is an essential step for other image processing steps such as edge detection, image segmentation, image compression, etc. Parallel Feature Extractor (PFE) meant to capture visual contents of images involves partitioning images into segments, detecting image overlaps if any, and controlling distributed and redistributed segments to extract the features. Working on low light intensity images make the PFE face challenges and closely depend on the quality of its pre-processing steps. Some papers have suggested many well established NR as well as PFE strategies however only few resources have suggested or mentioned the correlation between them. This paper reviews best approaches of the NR and the PFE with detailed explanation on the suggested correlation. This finding may suggest relevant strategies of the PFE development. With the help of knowledge based reasoning, computational approaches and algorithms, we present the correlation study between the NR and the PFE that can be useful for the development and enhancement of other existing PFE

  1. Assessment of noise levels generated by music shops in an urban city in Nigeria.

    Science.gov (United States)

    Ebare, M N; Omuemu, V O; Isah, E C

    2011-09-01

    To assess the level of noise generated by music shops in an urban city in Nigeria. Cross-sectional, descriptive study. The study involved music shops in three out of eight identified clusters of market areas in Benin City. A semi-structured, researcher-administered questionnaire was also used to collect data from music shop owners. Noise levels generated by speakers in the music shops were measured using a sound level meter, and blood pressure measurements were taken with a mercury sphygmomanometer. Of the 250 music shops studied, more than 90.0% generated noise levels >85 dB, and 54.8% had a continuous pattern of noise. Longer duration of working years was significantly associated with decreased hearing (P = 0.01), shouting when talking (P = 0.04) and high blood pressure (P = 0.003). The position of music dealers in relation to the speakers was significantly associated with shouting when talking (P = 0.000). A significant association was found between higher levels of noise and high blood pressure (P = 0.004). This study found very high levels of noise in music shops, which could be a source of occupational noise exposure among music dealers. Enlightenment campaigns on the hazards of exposure to loud noise and periodic audiometry examinations are recommended for this occupational group. Copyright © 2011 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  2. A Design of Experiments Investigation of Offset Streams for Supersonic Jet Noise Reduction

    Science.gov (United States)

    Henderson, Brenda; Papamoschou, Dimitri

    2014-01-01

    An experimental investigation into the noise characteristics of a dual-stream jet with four airfoils inserted in the fan nozzle was conducted. The intent of the airfoils was to deflect the fan stream relative to the core stream and, therefore, impact the development of the secondary potential core and noise radiated in the peak jet-noise direction. The experiments used a full-factorial Design of Experiments (DoE) approach to identify parameters and parameter interactions impacting noise radiation at two azimuthal microphone array locations, one of which represented a sideline viewing angle. The parameters studied included airfoil angle-of-attack, airfoil azimuthal location within the fan nozzle, and airfoil axial location relative to the fan-nozzle trailing edge. Jet conditions included subsonic and supersonic fan-stream Mach numbers. Heated jets conditions were simulated with a mixture of helium and air to replicate the exhaust velocity and density of the hot jets. The introduction of the airfoils was shown to impact noise radiated at polar angles in peak-jet noise direction and to have no impact on noise radiated at small and broadside polar angles and to have no impact on broadband-shock-associated noise. The DoE analysis showed the main effects impacting noise radiation at sideline-azimuthal-viewing angles included airfoil azimuthal angle for the airfoils on the lower side of the jet near the sideline array and airfoil trailing edge distance (with airfoils located at the nozzle trailing edge produced the lowest sound pressure levels). For an array located directly beneath the jet (and on the side of the jet from which the fan stream was deflected), the main effects impacting noise radiation included airfoil angle-of-attack and airfoil azimuthal angle for the airfoils located on the observation side of the jet as well and trailing edge distance. Interaction terms between multiple configuration parameters were shown to have significant impact on the radiated

  3. Study on traffic noise level of Sylhet by multiple regression analysis associated with health hazards

    Directory of Open Access Journals (Sweden)

    J. B. Alam, M. Jobair Bin Alam, M. M. Rahman, A. K. Dikshit, S. K. Khan

    Full Text Available The study reports the level of traffic-induced noise pollution in Sylhet City. For this purpose noise levels have been measured at thirty-seven major locations of the city from 7 am to 11 pm during the working days. It was observed that at all the locations the level of noise remains far above the acceptable limit for all the time. The noise level on the main road near residential area, hospital area and educational area were above the recommended level (65dBA. It was found that the predictive equations are in 60-70% correlated with the measured noise level. The study suggests that vulnerable institutions like school and hospital should be located about 60m away from the roadside unless any special arrangement to alleviate sound is used.

  4. Foundations of Active Control - Active Noise Reduction Helmets

    DEFF Research Database (Denmark)

    Elmkjær, Torsten Haaber Leth

    2008-01-01

    rate is increased which in turn most likely also will lead to an increased ANR bandwidth. The hybrid system is also constituted from a continuous-time feedback system (FBS) and a discrete-time FBS. The continuous-time FBS is primarily responsible for additional broadband noise reduction, whereas...... the discrete-time FBS primarily is responsible for the attenuation of periodic signals. Owing to the requirement on causal operation of a physical AC system time delays will also to a large extent determine the achievable performance in FFS design and in particular in FBS design. A quantity referred...... on a head and torso simulator (HATS), is exposed to diffuse sound field illumination. By applying the JCRSA method the spatially-weighted-averaged acquisition lead times provided by the reference sensors relative to the performance sensors are estimated to be as much as 800-900μs. The thesis also includes...

  5. Techniques for the reduction of low frequency noise in buildings

    NARCIS (Netherlands)

    Zuada Coelho, B.A.; Koopman, A.

    2012-01-01

    Vibration isolation of buildings is often achieved by introducing spring systems at the foundation level. This can be an effective measure, especially against vibrations induced by noise, but it is also very costly. Due to the current usage of the cities space, where buildings and infrastructures

  6. Preparation of Ultracold Atom Clouds at the Shot Noise Level

    DEFF Research Database (Denmark)

    Gajdacz, M.; Hilliard, A. J.; Kristensen, Mick

    2016-01-01

    We prepare number stabilized ultracold atom clouds through the real-time analysis of nondestructive images and the application of feedback. In our experiments, the atom number N∼10^6 is determined by high precision Faraday imaging with uncertainty ΔN below the shot noise level, i.e., ΔN... on this measurement, feedback is applied to reduce the atom number to a user-defined target, whereupon a second imaging series probes the number stabilized cloud. By this method, we show that the atom number in ultracold clouds can be prepared below the shot noise level....

  7. Aerodynamic Measurements of a Gulfstream Aircraft Model With and Without Noise Reduction Concepts

    Science.gov (United States)

    Neuhart, Dan H.; Hannon, Judith A.; Khorrami, Mehdi R.

    2014-01-01

    Steady and unsteady aerodynamic measurements of a high-fidelity, semi-span 18% scale Gulfstream aircraft model are presented. The aerodynamic data were collected concurrently with acoustic measurements as part of a larger aeroacoustic study targeting airframe noise associated with main landing gear/flap components, gear-flap interaction noise, and the viability of related noise mitigation technologies. The aeroacoustic tests were conducted in the NASA Langley Research Center 14- by 22-Foot Subsonic Wind Tunnel with the facility in the acoustically treated open-wall (jet) mode. Most of the measurements were obtained with the model in landing configuration with the flap deflected at 39º and the main landing gear on and off. Data were acquired at Mach numbers of 0.16, 0.20, and 0.24. Global forces (lift and drag) and extensive steady and unsteady surface pressure measurements were obtained. Comparison of the present results with those acquired during a previous test shows a significant reduction in the lift experienced by the model. The underlying cause was traced to the likely presence of a much thicker boundary layer on the tunnel floor, which was acoustically treated for the present test. The steady and unsteady pressure fields on the flap, particularly in the regions of predominant noise sources such as the inboard and outboard tips, remained unaffected. It is shown that the changes in lift and drag coefficients for model configurations fitted with gear/flap noise abatement technologies fall within the repeatability of the baseline configuration. Therefore, the noise abatement technologies evaluated in this experiment have no detrimental impact on the aerodynamic performance of the aircraft model.

  8. Noise reduction by support vector regression with a Ricker wavelet kernel

    International Nuclear Information System (INIS)

    Deng, Xiaoying; Yang, Dinghui; Xie, Jing

    2009-01-01

    We propose a noise filtering technology based on the least-squares support vector regression (LS-SVR), to improve the signal-to-noise ratio (SNR) of seismic data. We modified it by using an admissible support vector (SV) kernel, namely the Ricker wavelet kernel, to replace the conventional radial basis function (RBF) kernel in seismic data processing. We investigated the selection of the regularization parameter for the LS-SVR and derived a concise selecting formula directly from the noisy data. We used the proposed method for choosing the regularization parameter which not only had the advantage of high speed but could also obtain almost the same effectiveness as an optimal parameter method. We conducted experiments using synthetic data corrupted by the random noise of different types and levels, and found that our method was superior to the wavelet transform-based approach and the Wiener filtering. We also applied the method to two field seismic data sets and concluded that it was able to effectively suppress the random noise and improve the data quality in terms of SNR

  9. Noise reduction by support vector regression with a Ricker wavelet kernel

    Science.gov (United States)

    Deng, Xiaoying; Yang, Dinghui; Xie, Jing

    2009-06-01

    We propose a noise filtering technology based on the least-squares support vector regression (LS-SVR), to improve the signal-to-noise ratio (SNR) of seismic data. We modified it by using an admissible support vector (SV) kernel, namely the Ricker wavelet kernel, to replace the conventional radial basis function (RBF) kernel in seismic data processing. We investigated the selection of the regularization parameter for the LS-SVR and derived a concise selecting formula directly from the noisy data. We used the proposed method for choosing the regularization parameter which not only had the advantage of high speed but could also obtain almost the same effectiveness as an optimal parameter method. We conducted experiments using synthetic data corrupted by the random noise of different types and levels, and found that our method was superior to the wavelet transform-based approach and the Wiener filtering. We also applied the method to two field seismic data sets and concluded that it was able to effectively suppress the random noise and improve the data quality in terms of SNR.

  10. Effects of background noise on total noise annoyance

    Science.gov (United States)

    Willshire, K. F.

    1987-01-01

    Two experiments were conducted to assess the effects of combined community noise sources on annoyance. The first experiment baseline relationships between annoyance and noise level for three community noise sources (jet aircraft flyovers, traffic and air conditioners) presented individually. Forty eight subjects evaluated the annoyance of each noise source presented at four different noise levels. Results indicated the slope of the linear relationship between annoyance and noise level for the traffic noise was significantly different from that of aircraft and of air conditioner noise, which had equal slopes. The second experiment investigated annoyance response to combined noise sources, with aircraft noise defined as the major noise source and traffic and air conditioner noise as background noise sources. Effects on annoyance of noise level differences between aircraft and background noise for three total noise levels and for both background noise sources were determined. A total of 216 subjects were required to make either total or source specific annoyance judgements, or a combination of the two, for a wide range of combined noise conditions.

  11. Noise level estimation in weakly nonlinear slowly time-varying systems

    International Nuclear Information System (INIS)

    Aerts, J R M; Dirckx, J J J; Lataire, J; Pintelon, R

    2008-01-01

    Recently, a method using multisine excitation was proposed for estimating the frequency response, the nonlinear distortions and the disturbing noise of weakly nonlinear time-invariant systems. This method has been demonstrated on the measurement of nonlinear distortions in the vibration of acoustically driven systems such as a latex membrane, which is a good example of a time-invariant system [1]. However, not all systems are perfectly time invariant, e.g. biomechanical systems. This time variation can be misinterpreted as an elevated noise floor, and the classical noise estimation method gives a wrong result. Two improved methods to retrieve the correct noise information from the measurements are presented. Both of them make use of multisine excitations. First, it is demonstrated that the improved methods give the same result as the classical noise estimation method when applied to a time-invariant system (high-quality microphone membrane). Next, it is demonstrated that the new methods clearly give an improved estimate of the noise level on time-varying systems. As an application example results for the vibration response of an eardrum are shown

  12. Noise Levels in Two Emergency Departments Before and After the Introduction of Electronic Whiteboards

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2013-01-01

    . The maximum equivalent continuous noise levels across 1 second were above 80 dB(A) at all four coordination centres. At two of the centres above 80 dB(A) noises also occurred at night. After the introduction of electronic whiteboards the noise level was lowered at one ED but unchanged at the other ED...

  13. Maintaining reduced noise levels in a resource-constrained neonatal intensive care unit by operant conditioning.

    Science.gov (United States)

    Ramesh, A; Denzil, S B; Linda, R; Josephine, P K; Nagapoornima, M; Suman Rao, P N; Swarna Rekha, A

    2013-03-01

    To evaluate the efficacy of operant conditioning in sustaining reduced noise levels in the neonatal intensive care unit (NICU). Quasi-experimental study on quality of care. Level III NICU of a teaching hospital in south India. 26 staff employed in the NICU. (7 Doctors, 13 Nursing staff and 6 Nursing assistants). Operant conditioning of staff activity for 6 months. This method involves positive and negative reinforcement to condition the staff to modify noise generating activities. Comparing noise levels in decibel: A weighted [dB (A)] before conditioning with levels at 18 and 24 months after conditioning. Decibel: A weighted accounts for noise that is audible to human ears. Operant conditioning for 6 months sustains the reduced noise levels to within 62 dB in ventilator room 95% CI: 60.4 - 62.2 and isolation room (95% CI: 55.8 - 61.5). In the preterm room, noise can be maintained within 52 dB (95% CI: 50.8 - 52.6). This effect is statistically significant in all the rooms at 18 months (P = 0.001). At 24 months post conditioning there is a significant rebound of noise levels by 8.6, 6.7 and 9.9 dB in the ventilator, isolation and preterm room, respectively (P =0.001). Operant conditioning for 6 months was effective in sustaining reduced noise levels. At 18 months post conditioning, the noise levels were maintained within 62 dB (A), 60 dB (A) and 52 dB (A) in the ventilator, isolation and pre-term room, respectively. Conditioning needs to be repeated at 12 months in the ventilator room and at 18 months in the other rooms.

  14. The Relationship between Personality Type and Acceptable Noise Levels: A Pilot Study.

    Science.gov (United States)

    Franklin, Cliff; Johnson, Laura V; White, Letitia; Franklin, Clay; Smith-Olinde, Laura

    2013-01-01

    Objectives. This study examined the relationship between acceptable noise level (ANL) and personality. ANL is the difference between a person's most comfortable level for speech and the loudest level of background noise they are willing to accept while listening to speech. Design. Forty young adults with normal hearing participated. ANLs were measured and two personality tests (Big Five Inventory, Myers-Briggs Type Indicator) were administered. Results. The analysis revealed a correlation between ANL and the openness and conscientious personality dimensions from the Big Five Inventory; no correlation emerged between ANL and the Myers-Briggs personality types. Conclusions. Lower ANLs are correlated with full-time hearing aid use and the openness personality dimension; higher ANLs are correlated with part-time or hearing aid nonuse and the conscientious personality dimension. Current data suggest that those more open to new experiences may accept more noise and possibly be good hearing aid candidates, while those more conscientious may accept less noise and reject hearing aids, based on their unwillingness to accept background noise. Knowing something about a person's personality type may help audiologists determine if their patients will likely be good candidates for hearing aids.

  15. New adaptive statistical iterative reconstruction ASiR-V: Assessment of noise performance in comparison to ASiR.

    Science.gov (United States)

    De Marco, Paolo; Origgi, Daniela

    2018-03-01

    To assess the noise characteristics of the new adaptive statistical iterative reconstruction (ASiR-V) in comparison to ASiR. A water phantom was acquired with common clinical scanning parameters, at five different levels of CTDI vol . Images were reconstructed with different kernels (STD, SOFT, and BONE), different IR levels (40%, 60%, and 100%) and different slice thickness (ST) (0.625 and 2.5 mm), both for ASiR-V and ASiR. Noise properties were investigated and noise power spectrum (NPS) was evaluated. ASiR-V significantly reduced noise relative to FBP: noise reduction was in the range 23%-60% for a 0.625 mm ST and 12%-64% for the 2.5 mm ST. Above 2 mGy, noise reduction for ASiR-V had no dependence on dose. Noise reduction for ASIR-V has dependence on ST, being greater for STD and SOFT kernels at 2.5 mm. For the STD kernel ASiR-V has greater noise reduction for both ST, if compared to ASiR. For the SOFT kernel, results varies according to dose and ST, while for BONE kernel ASIR-V shows less noise reduction. NPS for CT Revolution has dose dependent behavior at lower doses. NPS for ASIR-V and ASiR is similar, showing a shift toward lower frequencies as the IR level increases for STD and SOFT kernels. The NPS is different between ASiR-V and ASIR with BONE kernel. NPS for ASiR-V appears to be ST dependent, having a shift toward lower frequencies for 2.5 mm ST. ASiR-V showed greater noise reduction than ASiR for STD and SOFT kernels, while keeping the same NPS. For the BONE kernel, ASiR-V presents a completely different behavior, with less noise reduction and modified NPS. Noise properties of the ASiR-V are dependent on reconstruction slice thickness. The noise properties of ASiR-V suggest the need for further measurements and efforts to establish new CT protocols to optimize clinical imaging. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  16. Pilot study of methods and equipment for in-home noise level measurements.

    Science.gov (United States)

    Neitzel, Richard L; Heikkinen, Maire S A; Williams, Christopher C; Viet, Susan Marie; Dellarco, Michael

    2015-01-15

    Knowledge of the auditory and non-auditory effects of noise has increased dramatically over the past decade, but indoor noise exposure measurement methods have not advanced appreciably, despite the introduction of applicable new technologies. This study evaluated various conventional and smart devices for exposure assessment in the National Children's Study. Three devices were tested: a sound level meter (SLM), a dosimeter, and a smart device with a noise measurement application installed. Instrument performance was evaluated in a series of semi-controlled tests in office environments over 96-hour periods, followed by measurements made continuously in two rooms (a child's bedroom and a most used room) in nine participating homes over a 7-day period with subsequent computation of a range of noise metrics. The SLMs and dosimeters yielded similar A-weighted average noise levels. Levels measured by the smart devices often differed substantially (showing both positive and negative bias, depending on the metric) from those measured via SLM and dosimeter, and demonstrated attenuation in some frequency bands in spectral analysis compared to SLM results. Virtually all measurements exceeded the Environmental Protection Agency's 45 dBA day-night limit for indoor residential exposures. The measurement protocol developed here can be employed in homes, demonstrates the possibility of measuring long-term noise exposures in homes with technologies beyond traditional SLMs, and highlights potential pitfalls associated with measurements made by smart devices.

  17. The Relationship between Personality Type and Acceptable Noise Levels: A Pilot Study

    OpenAIRE

    Franklin, Cliff; Johnson, Laura V.; White, Letitia; Franklin, Clay; Smith-Olinde, Laura

    2013-01-01

    Objectives. This study examined the relationship between acceptable noise level (ANL) and personality. ANL is the difference between a person’s most comfortable level for speech and the loudest level of background noise they are willing to accept while listening to speech. Design. Forty young adults with normal hearing participated. ANLs were measured and two personality tests (Big Five Inventory, Myers-Briggs Type Indicator) were administered. Results. The analysis revealed a correlation bet...

  18. BAYESIAN ANALYSIS OF WHITE NOISE LEVELS IN THE FIVE-YEAR WMAP DATA

    International Nuclear Information System (INIS)

    Groeneboom, N. E.; Eriksen, H. K.; Gorski, K.; Huey, G.; Jewell, J.; Wandelt, B.

    2009-01-01

    We develop a new Bayesian method for estimating white noise levels in CMB sky maps, and apply this algorithm to the five-year Wilkinson Microwave Anisotropy Probe (WMAP) data. We assume that the amplitude of the noise rms is scaled by a constant value, α, relative to a pre-specified noise level. We then derive the corresponding conditional density, P(α | s, C l , d), which is subsequently integrated into a general CMB Gibbs sampler. We first verify our code by analyzing simulated data sets, and then apply the framework to the WMAP data. For the foreground-reduced five-year WMAP sky maps and the nominal noise levels initially provided in the five-year data release, we find that the posterior means typically range between α = 1.005 ± 0.001 and α = 1.010 ± 0.001 depending on differencing assembly, indicating that the noise level of these maps are biased low by 0.5%-1.0%. The same problem is not observed for the uncorrected WMAP sky maps. After the preprint version of this letter appeared on astro-ph., the WMAP team has corrected the values presented on their web page, noting that the initially provided values were in fact estimates from the three-year data release, not from the five-year estimates. However, internally in their five-year analysis the correct noise values were used, and no cosmological results are therefore compromised by this error. Thus, our method has already been demonstrated in practice to be both useful and accurate.

  19. Comparison of measured and predicted airfoil self-noise with application to wind turbine noise reduction

    International Nuclear Information System (INIS)

    Dassen, T.; Parchen, R.; Guidati, G.; Wagner, S.; Kang, S.; Khodak, A.E.

    1998-01-01

    In the ongoing JOULE-III project 'Development of Design Tools for Reduced Aerodynamic Noise Wind Turbines (DRAW)', prediction codes for inflow-turbulence (IT) noise and turbulent boundary layer trailing-edge (TE) noise, are developed and validated. It is shown that the differences in IT noise radiation between airfoils having a different shape, are correctly predicted. The first, preliminary comparison made between predicted and measured TE noise spectra yields satisfactory results. 17 refs

  20. Critical assessment of day time traffic noise level at curbside open-air microenvironment of Kolkata City, India.

    Science.gov (United States)

    Kundu Chowdhury, Anirban; Debsarkar, Anupam; Chakrabarty, Shibnath

    2015-01-01

    The objective of the research work is to assess day time traffic noise level at curbside open-air microenvironment of Kolkata city, India under heterogeneous environmental conditions. Prevailing traffic noise level in terms of A-weighted equivalent noise level (Leq) at the microenvironment was in excess of 12.6 ± 2.1 dB(A) from the day time standard of 65 dB(A) for commercial area recommended by the Central Pollution Control Board (CPCB) of India. Noise Climate and Traffic Noise Index of the microenvironment were accounted for 13 ± 1.8 dB(A) and 88.8 ± 6.1 dB(A) respectively. A correlation analysis explored that prevailing traffic noise level of the microenvironment had weak negative (-0.21; p air temperature and relative humidity. A Varimax rotated principal component analysis explored that motorized traffic volume had moderate positive loading with background noise component (L90, L95, L99) and prevailing traffic noise level had very strong positive loading with peak noise component (L1, L5, L10). Background and peak noise component cumulatively explained 80.98 % of variance in the data set. Traffic noise level at curbside open-air microenvironment of Kolkata City was higher than the standard recommended by CPCB of India. It was highly annoying also. Air temperature and relative humidity had little influence and the peak noise component had the most significant influence on the prevailing traffic noise level at curbside open-air microenvironment. Therefore, traffic noise level at the microenvironment of the city can be reduced with careful honking and driving.

  1. A two-microphone noise reduction system for cochlear implant users with nearby microphones. Part II: Performance Evaluation

    OpenAIRE

    Kompis, Martin; Bertram, Matthias; Senn, Pascal; Müller, Joachim; Pelizzone, Marco; Häusler, Rudolf

    2008-01-01

    Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signa...

  2. Noise and vibration reduction technology in hybrid vehicle development; Hybrid sha kaihatsu ni okeru shindo soon teigen gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioa, T.; Sugita, H. [Toyota Motor Corp., Aichi (Japan)

    2000-03-01

    Accomplishing both environmental protection and good NVH performance has become a significant task in automotive development The first-in-the-world hybrid passenger car of mass production. 'Prius', has achieved superior NV performance compared with conventional vehicles with a 1.5-liter engine along with 50% reduction of fuel consumption and CO{sub 2} emissions. low HC, CO and NO{sub x} emissions. This paper describes NV reduction technology for solving problems peculiar to the hybrid vehicle such as engine start/stop vibration, drone noise at low engine speed and motor/generator noise and vibration. It also mentions application technology of low rolling resistance tires with light weight wheels and recycled material for sound proofing. (author)

  3. A Comparative Land Use-Based Analysis of Noise Pollution Levels in Selected Urban Centers of Nigeria.

    Science.gov (United States)

    Baloye, David O; Palamuleni, Lobina G

    2015-09-29

    Growth in the commercialization, mobility and urbanization of human settlements across the globe has greatly exposed world urban population to potentially harmful noise levels. The situation is more disturbing in developing countries like Nigeria, where there are no sacrosanct noise laws and regulations. This study characterized noise pollution levels in Ibadan and Ile-Ife, two urban areas of Southwestern Nigeria that have experienced significant increases in population and land use activities. Eight hundred noise measurements, taken at 20 different positions in the morning, afternoon, and evening of carefully selected weekdays, in each urban area, were used for this study. Findings put the average noise levels in the urban centers at between 53 dB(A) and 89 dB (A), a far cry from the World Health Organization (WHO) permissible limits in all the land use types, with highest noise pollution levels recorded for transportation, commercial, residential and educational land use types. The result of the one-way ANOVA test carried out on the dependent variable noise and fixed factor land use types reveals a statistically significant mean noise levels across the study area (F(3,34) = 15.13, p = 0.000). The study underscores noise pollution monitoring and the urgent need to control urban noise pollution with appropriate and effective policies.

  4. Long-term exposure to road traffic noise and incident diabetes

    DEFF Research Database (Denmark)

    Sørensen, Mette; Andersen, Zorana Jovanovic; Nordsborg, Rikke B

    2013-01-01

    Road traffic noise at normal urban levels can lead to stress and sleep disturbances. Both excess of stress hormones and reduction in sleep quality and duration may lead to higher risk for type 2 diabetes.Objective: We investigated whether long-term exposure to residential road traffic noise...

  5. Speckle noise reduction technique for Lidar echo signal based on self-adaptive pulse-matching independent component analysis

    Science.gov (United States)

    Xu, Fan; Wang, Jiaxing; Zhu, Daiyin; Tu, Qi

    2018-04-01

    Speckle noise has always been a particularly tricky problem in improving the ranging capability and accuracy of Lidar system especially in harsh environment. Currently, effective speckle de-noising techniques are extremely scarce and should be further developed. In this study, a speckle noise reduction technique has been proposed based on independent component analysis (ICA). Since normally few changes happen in the shape of laser pulse itself, the authors employed the laser source as a reference pulse and executed the ICA decomposition to find the optimal matching position. In order to achieve the self-adaptability of algorithm, local Mean Square Error (MSE) has been defined as an appropriate criterion for investigating the iteration results. The obtained experimental results demonstrated that the self-adaptive pulse-matching ICA (PM-ICA) method could effectively decrease the speckle noise and recover the useful Lidar echo signal component with high quality. Especially, the proposed method achieves 4 dB more improvement of signal-to-noise ratio (SNR) than a traditional homomorphic wavelet method.

  6. A noise level prediction method based on electro-mechanical frequency response function for capacitors.

    Science.gov (United States)

    Zhu, Lingyu; Ji, Shengchang; Shen, Qi; Liu, Yuan; Li, Jinyu; Liu, Hao

    2013-01-01

    The capacitors in high-voltage direct-current (HVDC) converter stations radiate a lot of audible noise which can reach higher than 100 dB. The existing noise level prediction methods are not satisfying enough. In this paper, a new noise level prediction method is proposed based on a frequency response function considering both electrical and mechanical characteristics of capacitors. The electro-mechanical frequency response function (EMFRF) is defined as the frequency domain quotient of the vibration response and the squared capacitor voltage, and it is obtained from impulse current experiment. Under given excitations, the vibration response of the capacitor tank is the product of EMFRF and the square of the given capacitor voltage in frequency domain, and the radiated audible noise is calculated by structure acoustic coupling formulas. The noise level under the same excitations is also measured in laboratory, and the results are compared with the prediction. The comparison proves that the noise prediction method is effective.

  7. Soundscape elaboration from anthrophonic adaptation of community noise

    Science.gov (United States)

    Teddy Badai Samodra, FX

    2018-03-01

    Under the situation of an urban environment, noise has been a critical issue in affecting the indoor environment. A reliable approach is required for evaluation of the community noise as one factor of anthrophonic in the urban environment. This research investigates the level of noise exposure from different community noise sources and elaborates the advantage of the noise disadvantages for soundscape innovation. Integrated building element design as a protector for noise control and speech intelligibility compliance using field experiment and MATLAB programming and modeling are also carried out. Meanwhile, for simulation analysis and building acoustic optimization, Sound Reduction-Speech Intelligibility and Reverberation Time are the main parameters for identifying tropical building model as case study object. The results show that the noise control should consider its integration with the other critical issue, thermal control, in an urban environment. The 1.1 second of reverberation time for speech activities and noise reduction more than 28.66 dBA for critical frequency (20 Hz), the speech intelligibility index could be reached more than fair assessment, 0.45. Furthermore, the environmental psychology adaptation result “Close The Opening” as the best method in high noise condition and personal adjustment as the easiest and the most adaptable way.

  8. Improved Kalman Filter Method for Measurement Noise Reduction in Multi Sensor RFID Systems

    Directory of Open Access Journals (Sweden)

    Min Chul Kim

    2011-10-01

    Full Text Available Recently, the range of available Radio Frequency Identification (RFID tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less Mean Squared Error (MSE than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments.

  9. Improved Kalman filter method for measurement noise reduction in multi sensor RFID systems.

    Science.gov (United States)

    Eom, Ki Hwan; Lee, Seung Joon; Kyung, Yeo Sun; Lee, Chang Won; Kim, Min Chul; Jung, Kyung Kwon

    2011-01-01

    Recently, the range of available radio frequency identification (RFID) tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less mean squared error (MSE) than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments.

  10. Sedimentary noise and sea levels linked to land-ocean water exchange and obliquity forcing.

    Science.gov (United States)

    Li, Mingsong; Hinnov, Linda A; Huang, Chunju; Ogg, James G

    2018-03-08

    In ancient hothouses lacking ice sheets, the origins of large, million-year (myr)-scale sea-level oscillations remain a mystery, challenging current models of sea-level change. To address this mystery, we develop a sedimentary noise model for sea-level changes that simultaneously estimates geologic time and sea level from astronomically forced marginal marine stratigraphy. The noise model involves two complementary approaches: dynamic noise after orbital tuning (DYNOT) and lag-1 autocorrelation coefficient (ρ 1 ). Noise modeling of Lower Triassic marine slope stratigraphy in South China reveal evidence for global sea-level variations in the Early Triassic hothouse that are anti-phased with continental water storage variations in the Germanic Basin. This supports the hypothesis that long-period (1-2 myr) astronomically forced water mass exchange between land and ocean reservoirs is a missing link for reconciling geological records and models for sea-level change during non-glacial periods.

  11. Experimental and theoretical sound transmission. [reduction of interior noise in aircraft

    Science.gov (United States)

    Roskam, J.; Muirhead, V. U.; Smith, H. W.; Durenberger, D. W.

    1978-01-01

    The capabilities of the Kansas University- Flight Research Center for investigating panel sound transmission as a step toward the reduction of interior noise in general aviation aircraft were discussed. Data obtained on panels with holes, on honeycomb panels, and on various panel treatments at normal incidence were documented. The design of equipment for panel transmission loss tests at nonnormal (slanted) sound incidence was described. A comprehensive theory-based prediction method was developed and shows good agreement with experimental observations of the stiffness controlled, the region, the resonance controlled region, and the mass-law region of panel vibration.

  12. Assessment of ambient noise levels in the intensive care unit of a university hospital

    Directory of Open Access Journals (Sweden)

    Hatem O Qutub

    2009-01-01

    Conclusion : Some sources of environmental noise, such as the use of oxygen, suction equipment or respirators are unavoidable. Nevertheless, hospital ICUs should have measures to minimize the level of exposure to noise in the ICU. Further research in this area might focus on the noise level and other modifiable environmental stress factors in the ICU that affect patients as well as the staff.

  13. Noise Reduction Design of the Volute for a Centrifugal Compressor

    Science.gov (United States)

    Song, Zhen; Wen, Huabing; Hong, Liangxing; Jin, Yudong

    2017-08-01

    In order to effectively control the aerodynamic noise of a compressor, this paper takes into consideration a marine exhaust turbocharger compressor as a research object. According to the different design concept of volute section, tongue and exit cone, six different volute models were established. The finite volume method is used to calculate the flow field, whiles the finite element method is used for the acoustic calculation. Comparison and analysis of different structure designs from three aspects: noise level, isentropic efficiency and Static pressure recovery coefficient. The results showed that under the concept of volute section model 1 yielded the best result, under the concept of tongue analysis model 3 yielded the best result and finally under exit cone analysis model 6 yielded the best results.

  14. Cost-Benefit Analysis of Rail-Noise Mitigation Programmes at European Level: Methodological Innovations from EURANO to STAIRRS

    OpenAIRE

    Aude Lenders; Nancy Da Silva; Walter Hecq; Baumgartner Thomas

    2001-01-01

    The STAIRRS project (2000-2002) is a follow-up of EURANO [1] and a Swiss study [2], in which the authors evaluated the efficiency of noise reduction measures in two European freight corridors. STAIRRS includes a cost-benefit analysis based on about 10,000 km of track modelled in seven countries. The benefits are defined in terms of the dB(A) experienced by those living in the rail corridors modelled. They are to be weighted by the number of persons benefiting each year from a noise reduction ...

  15. A comparative study of noise pollution levels in some selected areas in Ilorin Metropolis, Nigeria.

    Science.gov (United States)

    Oyedepo, Olayinka S; Saadu, Abdullahi A

    2009-11-01

    The noise pollution is a major problem for the quality of life in urban areas. This study was conducted to compare the noise pollution levels at busy roads/road junctions, passengers loading parks, commercial, industrial and residential areas in Ilorin metropolis. A total number of 47-locations were selected within the metropolis. Statistical analysis shows significant difference (P noise pollution levels between industrial areas and low density residential areas, industrial areas and high density areas, industrial areas and passengers loading parks, industrial areas and commercial areas, busy roads/road junctions and low density areas, passengers loading parks and commercial areas and commercial areas and low density areas. There is no significant difference (P > 0.05) in noise pollution levels between industrial areas and busy roads/road junctions, busy roads/road junctions and high density areas, busy roads/road junctions and passengers loading parks, busy roads/road junctions and commercial areas, passengers loading parks and high density areas, passengers loading parks and commercial areas and commercial areas and high density areas. The results show that Industrial areas have the highest noise pollution levels (110.2 dB(A)) followed by busy roads/Road junctions (91.5 dB(A)), Passengers loading parks (87.8 dB(A)) and Commercial areas (84.4 dB(A)). The noise pollution levels in Ilorin metropolis exceeded the recommended level by WHO at 34 of 47 measuring points. It can be concluded that the city is environmentally noise polluted and road traffic and industrial machineries are the major sources of it. Noting the noise emission standards, technical control measures, planning and promoting the citizens awareness about the high noise risk may help to relieve the noise problem in the metropolis.

  16. Advantages of binaural amplification to acceptable noise level of directional hearing aid users.

    Science.gov (United States)

    Kim, Ja-Hee; Lee, Jae Hee; Lee, Ho-Ki

    2014-06-01

    The goal of the present study was to examine whether Acceptable Noise Levels (ANLs) would be lower (greater acceptance of noise) in binaural listening than in monaural listening condition and also whether meaningfulness of background speech noise would affect ANLs for directional microphone hearing aid users. In addition, any relationships between the individual binaural benefits on ANLs and the individuals' demographic information were investigated. Fourteen hearing aid users (mean age, 64 years) participated for experimental testing. For the ANL calculation, listeners' most comfortable listening levels and background noise level were measured. Using Korean ANL material, ANLs of all participants were evaluated under monaural and binaural amplification with a counterbalanced order. The ANLs were also compared across five types of competing speech noises, consisting of 1- through 8-talker background speech maskers. Seven young normal-hearing listeners (mean age, 27 years) participated for the same measurements as a pilot testing. The results demonstrated that directional hearing aid users accepted more noise (lower ANLs) with binaural amplification than with monaural amplification, regardless of the type of competing speech. When the background speech noise became more meaningful, hearing-impaired listeners accepted less amount of noise (higher ANLs), revealing that ANL is dependent on the intelligibility of the competing speech. The individuals' binaural advantages in ANLs were significantly greater for the listeners with longer experience of hearing aids, yet not related to their age or hearing thresholds. Binaural directional microphone processing allowed hearing aid users to accept a greater amount of background noise, which may in turn improve listeners' hearing aid success. Informational masking substantially influenced background noise acceptance. Given a significant association between ANLs and duration of hearing aid usage, ANL measurement can be useful for

  17. Judgments of aircraft noise in a traffic noise background

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1975-01-01

    An investigation was conducted to determine subjective response to aircraft noise in different road traffic backgrounds. In addition, two laboratory techniques for presenting the aircraft noise with the background noise were evaluated. For one technique, the background noise was continuous over an entire test session; for the other, the background noise level was changed with each aircraft noise during a session. Subjective response to aircraft noise was found to decrease with increasing background noise level, for a range of typical indoor noise levels. Subjective response was found to be highly correlated with the Noise Pollution Level (NPL) measurement scale.

  18. Wideband noise observed at ground level in the auroral region

    International Nuclear Information System (INIS)

    Benson, R.F.; Desch, M.D.

    1991-01-01

    A sideband noise event was detected at ground level from the Andoya Rocket Range in Norway in January 1989. The signals were observed on four commercial communication receivers (tuned to 159, 515, 905, and 1200 kHz), an ionosonde (200-kHz to 3.5-MHz interference-free observations) and a riometer (32.5 MHz). The event, which occurred during a period of magnetic disturbance near magnetic midnight, was the only one observed during nearly 3 weeks of operations. This low frequency-of-occurrence is attributed partly to high local noise levels. The ease with which this event was identified on the ionograms produced by the local ionosonde suggests that routine ionosonde recordings should be inspected in search for such events. Such an effort would enhance existing research directed toward developing techniques for identifying quiet communication channels and help to identify the origin and frequency-of-occurrence of high-latitude wideband noise events. 20 refs

  19. Two Methods of Mechanical Noise Reduction of Recorded Speech During Phonation in an MRI devic

    Czech Academy of Sciences Publication Activity Database

    Přibil, J.; Horáček, Jaromír; Horák, Petr

    2011-01-01

    Roč. 11, č. 3 (2011), s. 92-98 ISSN 1335-8871 R&D Projects: GA ČR GA102/09/0989 Institutional research plan: CEZ:AV0Z20760514; CEZ:AV0Z20670512 Keywords : speech processing * noise reduction * NMR imaging Subject RIV: BI - Acoustics Impact factor: 0.418, year: 2011

  20. Meta-Analysis of Free-Response Studies, 1992-2008: Assessing the Noise Reduction Model in Parapsychology

    Science.gov (United States)

    Storm, Lance; Tressoldi, Patrizio E.; Di Risio, Lorenzo

    2010-01-01

    We report the results of meta-analyses on 3 types of free-response study: (a) ganzfeld (a technique that enhances a communication anomaly referred to as "psi"); (b) nonganzfeld noise reduction using alleged psi-enhancing techniques such as dream psi, meditation, relaxation, or hypnosis; and (c) standard free response (nonganzfeld, no noise…

  1. Innovative Technique for Noise Reduction in Spacecraft Doppler Tracking for Planetary Interior Studies

    Science.gov (United States)

    Notaro, V.; Armstrong, J. W.; Asmar, S.; Di Ruscio, A.; Iess, L.; Mariani, M., Jr.

    2017-12-01

    Precise measurements of spacecraft range rate, enabled by two-way microwave links, are used in radio science experiments for planetary geodesy including the determination of planetary gravitational fields for the purpose of modeling the interior structure. The final accuracies in the estimated gravity harmonic coefficients depend almost linearly on the Doppler noise in the link. We ran simulations to evaluate the accuracy improvement attainable in the estimation of the gravity harmonic coefficients of Venus (with a representative orbiter) and Mercury (with the BepiColombo spacecraft), using our proposed innovative noise-cancellation technique. We showed how the use of an additional, smaller and stiffer, receiving-only antenna could reduce the leading noise sources in a Ka-band two-way link such as tropospheric and antenna mechanical noises. This is achieved through a suitable linear combination (LC) of Doppler observables collected at the two antennas at different times. In our simulations, we considered a two-way link either from NASA's DSS 25 antenna in California or from ESA's DSA-3 antenna in Malargüe (Argentina). Moreover, we selected the 12-m Atacama Pathfinder EXperiment (APEX) in Chile as the three-way antenna and developed its tropospheric noise model using available atmospheric data and mechanical stability specifications. For an 8-hour Venus orbiter tracking pass in Chajnantor's winter/night conditions, the accuracy of the simulated LC Doppler observable at 10-s integration time is 6 mm/s, to be compared to 23 mm/s for the two-way link. For BepiColombo, we obtained 16.5 mm/s and 35 mm/s, respectively for the LC and two-way links. The benefits are even larger at longer time scales. Numerical simulations indicate that such noise reduction would provide significant improvements in the determination of Venus's and Mercury's gravity field coefficients. If implemented, this noise-reducing technique will be valuable for planetary geodesy missions, where the

  2. Reducing high Reynolds number hydroacoustic noise using superhydrophobic coating

    International Nuclear Information System (INIS)

    Elboth, Thomas; Reif, Bjørn Anders Pettersson; Andreassen, Øyvind; Martell, Michael B

    2011-01-01

    The objective of this study is to assess and quantify the effect of a superhydrophobic surface coating on turbulence-generated flow noise. The study utilizes results obtained from high Reynolds-number full-scale flow noise measurements taken on a commercial seismic streamer and results from low Reynolds-number direct numerical simulations. It is shown that it is possible to significantly reduce both the frictional drag and the levels of the turbulence generated flow noise even at very high Reynolds-numbers. For instance, frequencies below 10 Hz a reduction in the flow noise level of nearly 50% was measured. These results can be attributed to a reduced level of shear stress and change in the kinematic structure of the turbulence, both of which occur in the immediate vicinity of the superhydrophobic surface.

  3. A Noise Reduction Preprocessor for Mobile Voice Communication

    Directory of Open Access Journals (Sweden)

    Rainer Martin

    2004-07-01

    Full Text Available We describe a speech enhancement algorithm which leads to significant quality and intelligibility improvements when used as a preprocessor to a low bit rate speech coder. This algorithm was developed in conjunction with the mixed excitation linear prediction (MELP coder which, by itself, is highly susceptible to environmental noise. The paper presents novel as well as known speech and noise estimation techniques and combines them into a highly effective speech enhancement system. The algorithm is based on short-time spectral amplitude estimation, soft-decision gain modification, tracking of the a priori probability of speech absence, and minimum statistics noise power estimation. Special emphasis is placed on enhancing the performance of the preprocessor in nonstationary noise environments.

  4. Speckle noise reduction for optical coherence tomography based on adaptive 2D dictionary

    Science.gov (United States)

    Lv, Hongli; Fu, Shujun; Zhang, Caiming; Zhai, Lin

    2018-05-01

    As a high-resolution biomedical imaging modality, optical coherence tomography (OCT) is widely used in medical sciences. However, OCT images often suffer from speckle noise, which can mask some important image information, and thus reduce the accuracy of clinical diagnosis. Taking full advantage of nonlocal self-similarity and adaptive 2D-dictionary-based sparse representation, in this work, a speckle noise reduction algorithm is proposed for despeckling OCT images. To reduce speckle noise while preserving local image features, similar nonlocal patches are first extracted from the noisy image and put into groups using a gamma- distribution-based block matching method. An adaptive 2D dictionary is then learned for each patch group. Unlike traditional vector-based sparse coding, we express each image patch by the linear combination of a few matrices. This image-to-matrix method can exploit the local correlation between pixels. Since each image patch might belong to several groups, the despeckled OCT image is finally obtained by aggregating all filtered image patches. The experimental results demonstrate the superior performance of the proposed method over other state-of-the-art despeckling methods, in terms of objective metrics and visual inspection.

  5. Photonic microwave signals with zeptosecond-level absolute timing noise

    Science.gov (United States)

    Xie, Xiaopeng; Bouchand, Romain; Nicolodi, Daniele; Giunta, Michele; Hänsel, Wolfgang; Lezius, Matthias; Joshi, Abhay; Datta, Shubhashish; Alexandre, Christophe; Lours, Michel; Tremblin, Pierre-Alain; Santarelli, Giorgio; Holzwarth, Ronald; Le Coq, Yann

    2017-01-01

    Photonic synthesis of radiofrequency (RF) waveforms revived the quest for unrivalled microwave purity because of its ability to convey the benefits of optics to the microwave world. In this work, we perform a high-fidelity transfer of frequency stability between an optical reference and a microwave signal via a low-noise fibre-based frequency comb and cutting-edge photodetection techniques. We demonstrate the generation of the purest microwave signal with a fractional frequency stability below 6.5 × 10-16 at 1 s and a timing noise floor below 41 zs Hz-1/2 (phase noise below -173 dBc Hz-1 for a 12 GHz carrier). This outperforms existing sources and promises a new era for state-of-the-art microwave generation. The characterization is achieved through a heterodyne cross-correlation scheme with the lowermost detection noise. This unprecedented level of purity can impact domains such as radar systems, telecommunications and time-frequency metrology. The measurement methods developed here can benefit the characterization of a broad range of signals.

  6. Autonomous Slat-Cove-Filler Device for Reduction of Aeroacoustic Noise Associated with Aircraft Systems

    Science.gov (United States)

    Turner, Travis L. (Inventor); Kidd, Reggie T. (Inventor); Lockard, David P (Inventor); Khorrami, Mehdi R. (Inventor); Streett, Craig L. (Inventor); Weber, Douglas Leo (Inventor)

    2016-01-01

    A slat cove filler is utilized to reduce airframe noise resulting from deployment of a leading edge slat of an aircraft wing. The slat cove filler is preferably made of a super elastic shape memory alloy, and the slat cove filler shifts between stowed and deployed shapes as the slat is deployed. The slat cove filler may be configured such that a separate powered actuator is not required to change the shape of the slat cove filler from its deployed shape to its stowed shape and vice-versa. The outer contour of the slat cove filler preferably follows a profile designed to maintain accelerating flow in the gap between the slat cove filler and wing leading edge to provide for noise reduction.

  7. Theory of deep level trap effects on generation-recombination noise in HgCdTe photoconductors

    International Nuclear Information System (INIS)

    Iverson, A.E.; Smith, D.L.

    1985-01-01

    We present a theory of the effect of deep level centers on the generation-recombination (g-r) noise and responsivity of an intrinsic photoconductor. The deep level centers can influence the g-r noise and responsivity in three main ways: (i) they can shorten the bulk carrier lifetime by Shockley--Read--Hall recombination; (ii) for some values of the capture cross sections, deep level densities, and temperature, the deep levels can trap a significant fraction of the photogenerated minority carriers. This trapping reduces the effective minority carrier mobility and diffusivity and thus reduces the effect of carrier sweep out on both g-r noise and responsivity; (iii) the deep level centers add a new thermal noise source, which results from fluctuations between bound and free carriers. The strength of this new noise source decreases with decreasing temperature at a slower rate than band-to-band thermal g-r noise. Calculations have been performed for a X = 0.21, n-type Hg/sub 1-x/Cd/sub x/Te photoconductor using the parameters of a commonly occurring deep level center in this material. We find that for typical operating conditions photoconductive detector performance begins to degrade as the deep level density begins to exceed 10 16 cm -3

  8. Listening level of music through headphones in train car noise environments.

    Science.gov (United States)

    Shimokura, Ryota; Soeta, Yoshiharu

    2012-09-01

    Although portable music devices are useful for passing time on trains, exposure to music using headphones for long periods carries the risk of damaging hearing acuity. The aim of this study is to examine the listening level of music through headphones in the noisy environment of a train car. Eight subjects adjusted the volume to an optimum level (L(music)) in a simulated noisy train car environment. In Experiment I, the effects of noise level (L(train)) and type of train noise (rolling, squealing, impact, and resonance) were examined. Spectral and temporal characteristics were found to be different according to the train noise type. In Experiment II, the effects of L(train) and type of music (five vocal and five instrumental music) were examined. Each music type had a different pitch strength and spectral centroid, and each was evaluated by φ(1) and W(φ(0)), respectively. These were classified as factors of the autocorrelation function (ACF) of the music. Results showed that L(music) increased as L(train) increased in both experiments, while the type of music greatly influenced L(music). The type of train noise, however, only slightly influenced L(music). L(music) can be estimated using L(train) and the ACF factors φ(1) and W(φ(0)).

  9. Investment strategy due to the minimization of portfolio noise level by observations of coarse-grained entropy

    OpenAIRE

    Krzysztof Urbanowicz; Janusz A. Holyst

    2004-01-01

    Using a recently developed method of noise level estimation that makes use of properties of the coarse grained-entropy we have analyzed the noise level for the Dow Jones index and a few stocks from the New York Stock Exchange. We have found that the noise level ranges from 40 to 80 percent of the signal variance. The condition of a minimal noise level has been applied to construct optimal portfolios from selected shares. We show that implementation of a corresponding threshold investment stra...

  10. STUDY ON NOISE LEVEL GENERATED BY HUMAN ACTIVITIES IN SIBIU CITY, ROMANIA

    Directory of Open Access Journals (Sweden)

    Cristina STANCA-MOISE

    2014-10-01

    Full Text Available In this paper I have proposed an analysis and monitoring of the noise sources in the open spaces of air traffic, rail and car in Sibiu. From centralizing data obtained from the analysis of the measurements performed with equipment noise levels, we concluded that the noise and vibration produced by means of Transportation (air, road, rail can affect human health if they exceed limits. Noise is present and part of our lives and always a source of pollution as any of modern man is not conscious.

  11. External noise distinguishes attention mechanisms.

    Science.gov (United States)

    Lu, Z L; Dosher, B A

    1998-05-01

    We developed and tested a powerful method for identifying and characterizing the effect of attention on performance in visual tasks as due to signal enhancement, distractor exclusion, or internal noise suppression. Based on a noisy Perceptual Template Model (PTM) of a human observer, the method adds increasing amounts of external noise (white gaussian random noise) to the visual stimulus and observes the effect on performance of a perceptual task for attended and unattended stimuli. The three mechanisms of attention yield three "signature" patterns of performance. The general framework for characterizing the mechanisms of attention is used here to investigate the attentional mechanisms in a concurrent location-cued orientation discrimination task. Test stimuli--Gabor patches tilted slightly to the right or left--always appeared on both the left and the right of fixation, and varied independently. Observers were cued on each trial to attend to the left, the right, or evenly to both stimuli, and decide the direction of tilt of both test stimuli. For eight levels of added external noise and three attention conditions (attended, unattended, and equal), subjects' contrast threshold levels were determined. At low levels of external noise, attention affected threshold contrast: threshold contrasts for non-attended stimuli were systematically higher than for equal attention stimuli, which were, in turn, higher than for attended stimuli. Specifically, when the rms contrast of the external noise is below 10%, there is a consistent 17% elevation of contrast threshold from attended to unattended condition across all three subjects. For higher levels of external noise, attention conditions did not affect threshold contrast values at all. These strong results are characteristic of a signal enhancement, or equivalently, an internal additive noise reduction mechanism of attention.

  12. Evaluation of model-based versus non-parametric monaural noise-reduction approaches for hearing aids.

    Science.gov (United States)

    Harlander, Niklas; Rosenkranz, Tobias; Hohmann, Volker

    2012-08-01

    Single channel noise reduction has been well investigated and seems to have reached its limits in terms of speech intelligibility improvement, however, the quality of such schemes can still be advanced. This study tests to what extent novel model-based processing schemes might improve performance in particular for non-stationary noise conditions. Two prototype model-based algorithms, a speech-model-based, and a auditory-model-based algorithm were compared to a state-of-the-art non-parametric minimum statistics algorithm. A speech intelligibility test, preference rating, and listening effort scaling were performed. Additionally, three objective quality measures for the signal, background, and overall distortions were applied. For a better comparison of all algorithms, particular attention was given to the usage of the similar Wiener-based gain rule. The perceptual investigation was performed with fourteen hearing-impaired subjects. The results revealed that the non-parametric algorithm and the auditory model-based algorithm did not affect speech intelligibility, whereas the speech-model-based algorithm slightly decreased intelligibility. In terms of subjective quality, both model-based algorithms perform better than the unprocessed condition and the reference in particular for highly non-stationary noise environments. Data support the hypothesis that model-based algorithms are promising for improving performance in non-stationary noise conditions.

  13. Quality-aware features-based noise level estimator for block matching and three-dimensional filtering algorithm

    Science.gov (United States)

    Xu, Shaoping; Hu, Lingyan; Yang, Xiaohui

    2016-01-01

    The performance of conventional denoising algorithms is usually controlled by one or several parameters whose optimal settings depend on the contents of the processed images and the characteristics of the noises. Among these parameters, noise level is a fundamental parameter that is always assumed to be known by most of the existing denoising algorithms (so-called nonblind denoising algorithms), which largely limits the applicability of these nonblind denoising algorithms in many applications. Moreover, these nonblind algorithms do not always achieve the best denoised images in visual quality even when fed with the actual noise level parameter. To address these shortcomings, in this paper we propose a new quality-aware features-based noise level estimator (NLE), which consists of quality-aware features extraction and optimal noise level parameter prediction. First, considering that image local contrast features convey important structural information that is closely related to image perceptual quality, we utilize the marginal statistics of two local contrast operators, i.e., the gradient magnitude and the Laplacian of Gaussian (LOG), to extract quality-aware features. The proposed quality-aware features have very low computational complexity, making them well suited for time-constrained applications. Then we propose a learning-based framework where the noise level parameter is estimated based on the quality-aware features. Based on the proposed NLE, we develop a blind block matching and three-dimensional filtering (BBM3D) denoising algorithm which is capable of effectively removing additive white Gaussian noise, even coupled with impulse noise. The noise level parameter of the BBM3D algorithm is automatically tuned according to the quality-aware features, guaranteeing the best performance. As such, the classical block matching and three-dimensional algorithm can be transformed into a blind one in an unsupervised manner. Experimental results demonstrate that the

  14. Investment strategy due to the minimization of portfolio noise level by observations of coarse-grained entropy

    Science.gov (United States)

    Urbanowicz, Krzysztof; Hołyst, Janusz A.

    2004-12-01

    Using a recently developed method of noise level estimation that makes use of properties of the coarse-grained entropy, we have analyzed the noise level for the Dow Jones index and a few stocks from the New York Stock Exchange. We have found that the noise level ranges from 40% to 80% of the signal variance. The condition of a minimal noise level has been applied to construct optimal portfolios from selected shares. We show that the implementation of a corresponding threshold investment strategy leads to positive returns for historical data.

  15. The Usability of Noise Level from Rock Cutting for the Prediction of Physico-Mechanical Properties of Rocks

    Science.gov (United States)

    Delibalta, M. S.; Kahraman, S.; Comakli, R.

    2015-11-01

    Because the indirect tests are easier and cheaper than the direct tests, the prediction of rock properties from the indirect testing methods is important especially for the preliminary investigations. In this study, the predictability of the physico-mechanical rock properties from the noise level measured during cutting rock with diamond saw was investigated. Noise measurement test, uniaxial compressive strength (UCS) test, Brazilian tensile strength (BTS) test, point load strength (Is) test, density test, and porosity test were carried out on 54 different rock types in the laboratory. The results were statistically analyzed to derive estimation equations. Strong correlations between the noise level and the mechanical rock properties were found. The relations follow power functions. Increasing rock strength increases the noise level. Density and porosity also correlated strongly with the noise level. The relations follow linear functions. Increasing density increases the noise level while increasing porosity decreases the noise level. The developed equations are valid for the rocks with a compressive strength below 150 MPa. Concluding remark is that the physico-mechanical rock properties can reliably be estimated from the noise level measured during cutting the rock with diamond saw.

  16. Assessment of ambient noise levels in the urban residential streets of Eastern Alexandria, Egypt.

    Science.gov (United States)

    Zaki, Gehan R

    2012-12-01

    Street of Alexandria have numerous unplanned, mixed, and noisy activities that may interfere with public health and comfort. The aim of this study was to assess A-weighted ambient noise levels in urban residential streets of Eastern Alexandria, Egypt, from September 2010 to January 2011, with the objective of recommending corrective actions to minimize high noise levels. A descriptive cross-sectional study was carried out, in which A-weighted ambient noise levels were measured on the basis of 24-h periods, using Ono sokki la-5120--precision integrating sound level meter, from September 2010 to January 2011. The measurements were taken on three streets, which were selected using stratified random sampling. Seven measurement sites, along the three streets under study, were selected by site visits according to predetermined criteria. A-weighted ambient noise levels (LAeq) were the highest [70.7 (24.2) dB] on high-traffic-density and high-human-activity streets followed by streets with moderate and low traffic density and human activity [67.5 (31.3) and 62.8 (38.2) dB], respectively. It varied significantly depending on means of transportation (road traffic, train, and/or tram) and human activities (parking lots, shops, and/or street merchants). The A-weighted ambient noise levels on urban residential streets of Eastern Alexandria, Egypt, exceeded the Egyptian National Standards during the three periods of the day (daytime, evening, and night), except in some relatively quiet locations during the night. Consequently, remedial actions to reduce noise levels were recommended.

  17. The Effect of the Cholesterol Levels on Noise-Induced Hearing Loss.

    Science.gov (United States)

    Demir, Mehmet Gokhan; Aydin, Sedat

    2018-01-01

    Introduction  Noise-induced hearing loss (NIHL), which is one of the most common occupational diseases among industrialized populations, is associated with longstanding exposure to high levels of noise. The pathogenesis of NIHL is not clear, but some genes and their activity at the tissue level have been investigated. Hypercholesterolemia, which can disturb the microcirculation, can be one of the underlying pathologies in hearing loss. Objective  To investigate the relationship between NIHL and hypercholesterolemia. Methods  The study group was selected among workers who had an occupational exposure of 85 dB of noise for at least 10 years. The audiologic assessment was recorded at seven frequencies (500 Hz, 1,000 Hz, 2,000 Hz, 3,000 Hz, 4,000 Hz, 6,000 Hz and 8,000 Hz). A total of 456 workers were included in the study and divided into two groups: the control group (252 patients) and the NIHL group (204 patients). After the audiologic measurement, blood samples were taken and investigated for blood cholesterol levels. According to these results, the groups were compared. Results  Both groups were similarly distributed regarding age and occupational exposure time ( p  > 0.05). We could not detect any association between cholesterol levels and noise-induced hearing loss ( p   0.05). Conclusion  Noise-induced hearing loss is still a common occupational problem that can be prevented by hearing conservation programs and occupational health and safety training. Still, we know little about the relationship between NIHL and hypercholesterolemia. According to our findings, we cannot detect any relationship. Controlled studies and studies with human individuals can be made possible in the future with diagnostic innovations in tissue imaging and tissue microcircular sampling.

  18. Phase noise reduction by self-phase locking in semiconductor lasers using phase conjugate feedback

    DEFF Research Database (Denmark)

    Petersen, Lykke; Gliese, Ulrik Bo; Nielsen, Torben Nørskov

    1994-01-01

    noise takes a finite-low value corresponding to a state of first-order self-phase locking of the laser. As a result, the spectral shape of the laser signal does not remain Lorentzian but collapses around the carrier to a delta function with a close to carrier noise level of less than -137 d...

  19. A survey of acoustic conditions and noise levels in secondary school classrooms in England.

    Science.gov (United States)

    Shield, Bridget; Conetta, Robert; Dockrell, Julie; Connolly, Daniel; Cox, Trevor; Mydlarz, Charles

    2015-01-01

    An acoustic survey of secondary schools in England has been undertaken. Room acoustic parameters and background noise levels were measured in 185 unoccupied spaces in 13 schools to provide information on the typical acoustic environment of secondary schools. The unoccupied acoustic and noise data were correlated with various physical characteristics of the spaces. Room height and the amount of glazing were related to the unoccupied reverberation time and therefore need to be controlled to reduce reverberation to suitable levels for teaching and learning. Further analysis of the unoccupied data showed that the introduction of legislation relating to school acoustics in England and Wales in 2003 approximately doubled the number of school spaces complying with current standards. Noise levels were also measured during 274 lessons to examine typical levels generated during teaching activities in secondary schools and to investigate the influence of acoustic design on working noise levels in the classroom. Comparison of unoccupied and occupied data showed that unoccupied acoustic conditions affect the noise levels occurring during lessons. They were also related to the time spent in disruption to the lessons (e.g., students talking or shouting) and so may also have an impact upon student behavior in the classroom.

  20. The Effects of Hearing Aid Directional Microphone and Noise Reduction Processing on Listening Effort in Older Adults with Hearing Loss.

    Science.gov (United States)

    Desjardins, Jamie L

    2016-01-01

    Older listeners with hearing loss may exert more cognitive resources to maintain a level of listening performance similar to that of younger listeners with normal hearing. Unfortunately, this increase in cognitive load, which is often conceptualized as increased listening effort, may come at the cost of cognitive processing resources that might otherwise be available for other tasks. The purpose of this study was to evaluate the independent and combined effects of a hearing aid directional microphone and a noise reduction (NR) algorithm on reducing the listening effort older listeners with hearing loss expend on a speech-in-noise task. Participants were fitted with study worn commercially available behind-the-ear hearing aids. Listening effort on a sentence recognition in noise task was measured using an objective auditory-visual dual-task paradigm. The primary task required participants to repeat sentences presented in quiet and in a four-talker babble. The secondary task was a digital visual pursuit rotor-tracking test, for which participants were instructed to use a computer mouse to track a moving target around an ellipse that was displayed on a computer screen. Each of the two tasks was presented separately and concurrently at a fixed overall speech recognition performance level of 50% correct with and without the directional microphone and/or the NR algorithm activated in the hearing aids. In addition, participants reported how effortful it was to listen to the sentences in quiet and in background noise in the different hearing aid listening conditions. Fifteen older listeners with mild sloping to severe sensorineural hearing loss participated in this study. Listening effort in background noise was significantly reduced with the directional microphones activated in the hearing aids. However, there was no significant change in listening effort with the hearing aid NR algorithm compared to no noise processing. Correlation analysis between objective and self

  1. A combined noise reduction and torque enhancement system for an I. C. engine

    Energy Technology Data Exchange (ETDEWEB)

    Hutchins, S.M.; Stothers, Ian; McDougall, N.M.

    1993-02-10

    The present invention provides a combined noise reduction and torque enhancement system for an internal combustion engine. It comprises means for periodically constricting or occluding the exhaust and/or inlet at least one frequency related to the rotation frequency of the engine. In a preferred embodiment of the invention, the constriction means comprises a plug member arranged to be oscillated in an aperture along the axis of flow of gas in the exhaust and/or inlet. (author)

  2. Does the acceptable noise level (ANL) predict hearing-aid use?

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Brännström, K Jonas

    2014-01-01

    OBJECTIVE: It has been suggested that individuals have an inherent acceptance of noise in the presence of speech, and that different acceptance of noise results in different hearing-aid (HA) use. The acceptable noise level (ANL) has been proposed for measurement of this property. It has been...... claimed that the ANL magnitude can predict hearing-aid use patterns. Many papers have been published reporting on different aspects of ANL, but none have challenged the predictive power of ANL. The purpose of this study was to discuss whether ANL can predict HA use and how more reliable ANL results can...... reviewed journals as well as a number of papers from trade journals, posters and oral presentations from audiology conventions. CONCLUSIONS: An inherent acceptance of noise in the presence of speech may exist, but no method for precise measurement of ANL is available. The ANL model for prediction of HA use...

  3. Noise level in a neonatal intensive care unit in Santa Marta - Colombia.

    Science.gov (United States)

    Garrido Galindo, Angélica Patricia; Camargo Caicedo, Yiniva; Velez-Pereira, Andres M

    2017-09-30

    The environment of neonatal intensive care units is influenced by numerous sources of noise emission, which contribute to raise the noise levels, and may cause hearing impairment and other physiological and psychological changes on the newborn, as well as problems with care staff. To evaluate the level and sources of noise in the neonatal intensive care unit. Sampled for 20 consecutive days every 60 seconds in A-weighting curves and fast mode with a Type I sound level meter. Recorded the average, maximum and minimum, and the 10th, 50th and 90th percentiles. The values are integrated into hours and work shift, and studied by analysis of variance. The sources were characterized in thirds of octaves. The average level was 64.00 ±3.62 dB(A), with maximum of 76.04 ±5.73 dB(A), minimum of 54.84 ±2.61dB(A), and background noise of 57.95 ±2.83 dB(A). We found four sources with levels between 16.8-63.3 dB(A). Statistical analysis showed significant differences between the hours and work shift, with higher values in the early hours of the day. The values presented exceed the standards suggested by several organizations. The sources identified and measured recorded high values in low frequencies.

  4. Survey of Traffic Noise Reduction Products, Materials, and Technologies.

    Science.gov (United States)

    2008-12-01

    Noise is one of the most pervasive forms of environmental pollution. It is everywhere and affects our lives at : home, work and play. By definition, noise is any unwanted or excessive sound. Highway traffic noise is a : major issue for transportation...

  5. Compressor noise control begins with design--Part 2

    International Nuclear Information System (INIS)

    Frank, L.

    1993-01-01

    Reduction of noise pollution at gas compressor stations associated with natural gas pipelines and distribution systems, has long been a complex problem. Specified noise levels of individual components tell nothing of the overall system when it is installed and placed in a site-specific setting. Further, testing for compliance performance guarantees is virtually impossible to conduct at a distant location because one cannot distinguish among various contributing noise sources. This paper develops a plan for calculating an estimate of sound generation from a compressor station and the methods for controlling and measuring sounds of individual components. It also classifies the types of noise and gives various methods of dealing with each noise type

  6. The Analysis of Low Noise Protection Barriers Influence on Tram Traffic Noise Levels

    Directory of Open Access Journals (Sweden)

    Ahac Maja

    2013-07-01

    Full Text Available The paper describes the analysis of tram traffic noise situation in residential areas in the vicinity of Drzic Avenue, one of the major routes between the northern and southern part of the Croatian capital city Zagreb, and the effect of low barriers placed by the tracks on tram noise mitigation. In order to evaluate the effect of planned protection measure, noise models were produced and verified with short-term field measurements. Calculations were conducted by means of noise prediction software, using European interim noise prediction method and 3D model of analyzed area. Finally, the results of noise calculations for existing tram traffic situation and planned measure of protection are presented on noise maps.

  7. Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

    Science.gov (United States)

    Widmann, Gerlig; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Al-Ekrish, Asma'a A

    2017-05-01

    Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. • Ultra-low-dose MDCT protocols allowed more than 90 % reductions in dose. • Decreasing the dose generally increased density and noise. • Effect of IRT on density and noise varies with reconstruction kernel. • Accuracy of low-dose protocols for interpretation of bony anatomy not known. • Effect of low doses on accuracy of computer-aided design models unknown.

  8. Improved CEEMDAN-wavelet transform de-noising method and its application in well logging noise reduction

    Science.gov (United States)

    Zhang, Jingxia; Guo, Yinghai; Shen, Yulin; Zhao, Difei; Li, Mi

    2018-06-01

    The use of geophysical logging data to identify lithology is an important groundwork in logging interpretation. Inevitably, noise is mixed in during data collection due to the equipment and other external factors and this will affect the further lithological identification and other logging interpretation. Therefore, to get a more accurate lithological identification it is necessary to adopt de-noising methods. In this study, a new de-noising method, namely improved complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN)-wavelet transform, is proposed, which integrates the superiorities of improved CEEMDAN and wavelet transform. Improved CEEMDAN, an effective self-adaptive multi-scale analysis method, is used to decompose non-stationary signals as the logging data to obtain the intrinsic mode function (IMF) of N different scales and one residual. Moreover, one self-adaptive scale selection method is used to determine the reconstruction scale k. Simultaneously, given the possible frequency aliasing problem between adjacent IMFs, a wavelet transform threshold de-noising method is used to reduce the noise of the (k-1)th IMF. Subsequently, the de-noised logging data are reconstructed by the de-noised (k-1)th IMF and the remaining low-frequency IMFs and the residual. Finally, empirical mode decomposition, improved CEEMDAN, wavelet transform and the proposed method are applied for analysis of the simulation and the actual data. Results show diverse performance of these de-noising methods with regard to accuracy for lithological identification. Compared with the other methods, the proposed method has the best self-adaptability and accuracy in lithological identification.

  9. Annoyance rating of wind turbine noise

    International Nuclear Information System (INIS)

    Iredale, R.

    1993-01-01

    Annoyance rating is important, but more important still is agreement on techniques for formulating minimal complaint criteria for design and specification purposes thus integrating noise control into the plant at the outset. A minimal complaint design criteria is suggested that finds its origin in the logic and techniques used successfully over many years for a wide range of power plant and other installations. The criterion is based on the masking of the wind turbine noise by the wind generated background noise. Satisfactory use of the criterion depends on the specification of inaudibility for the tones generated by the mechanical plant. Wind turbines generate more drive train noise than is realized and this contains many tones which tend to characterize the noise. Reduction of drive train noise would not only reduce the overall noise level but also give it a more acceptable character providing a margin against complaint in unusual circumstances of propagation. This requires very careful design of noise and vibration control in individual components. Vibration isolation between the support structures and the nacelle also requires careful attention. (UK)

  10. A trade-off analysis design tool. Aircraft interior noise-motion/passenger satisfaction model

    Science.gov (United States)

    Jacobson, I. D.

    1977-01-01

    A design tool was developed to enhance aircraft passenger satisfaction. The effect of aircraft interior motion and noise on passenger comfort and satisfaction was modelled. Effects of individual aircraft noise sources were accounted for, and the impact of noise on passenger activities and noise levels to safeguard passenger hearing were investigated. The motion noise effect models provide a means for tradeoff analyses between noise and motion variables, and also provide a framework for optimizing noise reduction among noise sources. Data for the models were collected onboard commercial aircraft flights and specially scheduled tests.

  11. Real-time noise reduction for Mössbauer spectroscopy through online implementation of a modified Kalman filter

    Energy Technology Data Exchange (ETDEWEB)

    Abrecht, David G., E-mail: david.abrecht@pnnl.gov [National Security Directorate, Pacific Northwest National Laboratory, 902 Battelle Blvd., Richland, WA 99352 (United States); Schwantes, Jon M. [National Security Directorate, Pacific Northwest National Laboratory, 902 Battelle Blvd., Richland, WA 99352 (United States); Kukkadapu, Ravi K. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 902 Battelle Blvd., Richland, WA 99352 (United States); McDonald, Benjamin S.; Eiden, Gregory C.; Sweet, Lucas E. [National Security Directorate, Pacific Northwest National Laboratory, 902 Battelle Blvd., Richland, WA 99352 (United States)

    2015-02-11

    Spectrum-processing software that incorporates a Gaussian smoothing kernel within the statistics of first-order Kalman filtration has been developed to provide cross-channel spectral noise reduction for increased real-time signal-to-noise ratios for Mössbauer spectroscopy. The filter was optimized for the breadth of the Gaussian using the Mössbauer spectrum of natural iron foil, and comparisons among the peak broadening, signal-to-noise ratios, and shifts in the calculated hyperfine parameters are presented. The results of optimization give a maximum improvement in the signal-to-noise ratio of 51.1% over the unfiltered spectrum at a Gaussian breadth of 27 channels, or 2.5% of the total spectrum width. The full-width half-maximum of the spectrum peaks showed an increase of 19.6% at this optimum point, indicating a relatively weak increase in the peak broadening relative to the signal enhancement, leading to an overall increase in the observable signal. Calculations of the hyperfine parameters showed that no statistically significant deviations were introduced from the application of the filter, confirming the utility of this filter for spectroscopy applications.

  12. Noise reduction in Lidar signal using correlation-based EMD combined with soft thresholding and roughness penalty

    Science.gov (United States)

    Chang, Jianhua; Zhu, Lingyan; Li, Hongxu; Xu, Fan; Liu, Binggang; Yang, Zhenbo

    2018-01-01

    Empirical mode decomposition (EMD) is widely used to analyze the non-linear and non-stationary signals for noise reduction. In this study, a novel EMD-based denoising method, referred to as EMD with soft thresholding and roughness penalty (EMD-STRP), is proposed for the Lidar signal denoising. With the proposed method, the relevant and irrelevant intrinsic mode functions are first distinguished via a correlation coefficient. Then, the soft thresholding technique is applied to the irrelevant modes, and the roughness penalty technique is applied to the relevant modes to extract as much information as possible. The effectiveness of the proposed method was evaluated using three typical signals contaminated by white Gaussian noise. The denoising performance was then compared to the denoising capabilities of other techniques, such as correlation-based EMD partial reconstruction, correlation-based EMD hard thresholding, and wavelet transform. The use of EMD-STRP on the measured Lidar signal resulted in the noise being efficiently suppressed, with an improved signal to noise ratio of 22.25 dB and an extended detection range of 11 km.

  13. The impact of noise level on students' learning performance at state elementary school in Medan

    Science.gov (United States)

    Buchari, Matondang, Nazaruddin

    2017-06-01

    This study was conducted to determine the level and impact of noise on pupils' learning performance that was observed through a survey at State Elementary School (SDN 060882), which is located on the corner of Abdullah Lubis Street and Pattimura Medan Street. The study was done by measuring the noise level using the Threshold Limit Value (TLV) by taking 24 locations as the measurement points. The results indicated that the noise levels exceeded the standard TLV >55 dBA as regulated in the Decree of the Minister of Environment No. KEP/48/MENLH/11/1996. According to the data processing, the noise level at school was 70.79 dBA. The classrooms were classified into noisy zones based on the Noise Mapping. Those in Red Zone which noise level were in the range of (69-75 dBA) were Class IIIa, Class IVb, and Class VI. In addition, those in Yellow Zone which were in the range of (65-69 dBA) were Class II, Class IIIa, Class IVa and Class V. The noise brought the physiological impact in the forms of dizziness that had the highest percentage of 22% and emotional and uncomfortable feeling of 21%; the communication impact of teacher's explanation disturbance of 22%; and Pupils' learning performance was evidenced to decline of 22%. Some improvements are suggested to reduce the noise such as the reposition of windows, acoustic material to cover the classrooms' wall, and bamboo trees or grasses as the barried around the school area.

  14. Reduction of belt CVT gear noise by gear train modification. Optimize vibration characteristics of gear train; Belt CVT no gear noise teigen gijutsu. Gear train shindo tokusei no saitekika

    Energy Technology Data Exchange (ETDEWEB)

    Arimatsu, M; Kawakami, T [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    With the reduction of vehicle noise, the requirements for an efficient method to reduce transmission gear noise have become stronger yearly. So far efforts to reduce gear noise have generally focused on ways of improving the gears themselves. In addition to these traditional methods, it proved very beneficial to us to optimize the gear train structure. Nissan has just released the new Belt CVT for 2.0L Front wheel drive vehicles. We have been analyzing vibration of the gear train by using a finite element model since the early development stage, and we could achieve the quiet gears effectively. 2 refs., 9 figs.

  15. Sensitivity of PPI analysis to differences in noise reduction strategies.

    Science.gov (United States)

    Barton, M; Marecek, R; Rektor, I; Filip, P; Janousova, E; Mikl, M

    2015-09-30

    In some fields of fMRI data analysis, using correct methods for dealing with noise is crucial for achieving meaningful results. This paper provides a quantitative assessment of the effects of different preprocessing and noise filtering strategies on psychophysiological interactions (PPI) methods for analyzing fMRI data where noise management has not yet been established. Both real and simulated fMRI data were used to assess these effects. Four regions of interest (ROIs) were chosen for the PPI analysis on the basis of their engagement during two tasks. PPI analysis was performed for 32 different preprocessing and analysis settings, which included data filtering with RETROICOR or no such filtering; different filtering of the ROI "seed" signal with a nuisance data-driven time series; and the involvement of these data-driven time series in the subsequent PPI GLM analysis. The extent of the statistically significant results was quantified at the group level using simple descriptive statistics. Simulated data were generated to assess statistical improvement of different filtering strategies. We observed that different approaches for dealing with noise in PPI analysis yield differing results in real data. In simulated data, we found RETROICOR, seed signal filtering and the addition of data-driven covariates to the PPI design matrix significantly improves results. We recommend the use of RETROICOR, and data-driven filtering of the whole data, or alternatively, seed signal filtering with data-driven signals and the addition of data-driven covariates to the PPI design matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Noise Reduction Properties of an Experimental Bituminous Slurry with Crumb Rubber Incorporated by the Dry Process

    Directory of Open Access Journals (Sweden)

    Moisés Bueno

    2014-08-01

    Full Text Available Nowadays, cold technology for asphalt pavement in the field of road construction is considered as an alternative solution to conventional procedures from both an economic and environmental point of view. Among these techniques, bituminous slurry surfacing is obtaining an important role due to the properties of the obtained wearing course. The functional performance of this type of surfaces is directly related to its rough texture. Nevertheless, this parameter has a significant influence on the tire/road noise generation. To reduce this undesirable effect on the sound performance, new designs of elastic bituminous slurries have been developed. Within the FENIX project, this work presents the acoustical characterization of an experimental bituminous slurry with crumb rubber from wasted automobile tires incorporated by the dry process. The obtained results show that, under controlled operational parameters, the close proximity sound levels associated to the experimental slurry are considerably lower than those emitted by a conventional slurry wearing course. However, after one year of supporting traffic loads and different weather conditions, the evaluated bituminous slurry, although it conserves the original noise reduction properties in relation to the conventional one, noticeably increases the generated sound emission. Therefore, it is required to continue improving the design of experimental surfaces in order to enhance its long-term performance.

  17. Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette.

    Science.gov (United States)

    Altuncu, E; Akman, I; Kulekci, S; Akdas, F; Bilgen, H; Ozek, E

    2009-07-01

    The purposes of this study were to measure the noise level of a busy neonatal intensive care unit (NICU) and to determine the effect of sound absorbing panel (SAP) on the level of noise inside the isolette. The sound pressure levels (SPL) of background noise, baby crying, alarms and closing of isolette's door/portholes were measured by a 2235-Brüel&Kjaer Sound Level Meter. Readings were repeated after applying SAP (3D pyramidal shaped open cell polyurethane foam) to the three lateral walls and ceiling of the isolette. The median SPL of background noise inside the NICU was 56dBA and it decreased to 47dBA inside the isolette. The median SPL of monitor alarms and baby crying inside the isolette were not different than SPL measured under radiant warmer (p>0.05). With SAP, the median SPL of temperature alarm inside the isolette decreased significantly from 82 to 72dBA, monitor alarm from 64 to 56dBA, porthole closing from 81 to 74dBA, and isolette door closing from 80 to 68dBA (pnoise produced by baby crying when SAP was used in the isolette (79dBA vs 69dBA, respectively) (pnoise. The noise level in our NICU is significantly above the universally recommended levels. Being inside the isolette protects infants from noise sources produced outside the isolette. However, very high noises are produced inside the isolette as well. Sound absorbing panel can be a simple solution and it attenuated the noise levels inside the isolette.

  18. Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.

    Science.gov (United States)

    Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari

    2017-06-01

    Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.

  19. EVALUATION OF THE ENVIRONMENTAL NOISE LEVELS IN ABUJA MUNICIPALITY USING MOBILE PHONES.

    Science.gov (United States)

    Ibekwe, T; Folorunso, D; Ebuta, A; Amodu, J; Nwegbu, M; Mairami, Z; Liman, I; Okebaram, C; Chimdi, C; Durogbola, B; Suleiman, H; Mamven, H; Baamlong, N; Dahilo, E; Gbujie, I; Ibekwe, P; Nwaorgu, O

    2016-12-01

    Noise remains a nuisance which impacts negatively on the physical, social and psychological wellbeing of man. It aggravates chronic illnesses like hypertension and other cardiopulmonary diseases. Unfortunately, increased activities from industrialization and technological transfers/drifts have tumultuously led to increased noise pollution in most of our fast growing cities today and hence the need for concerted efforts in monitoring and regulating our environmental noise. To assess the equivalent noise level (Leq) in Abuja municipality and promote a simple method for regular assessment of Leq within our environment. This is a cross-sectional community based study of the environmental Leq of Abuja municipality conducted between January 2014 and January 2016. The city was divided into 12 segments including residential, business and market areas via the Abuja Geographic Information System. The major markets were captured separately on a different scale. Measurements were taken with the mobile phone softwares having validated this with Extech 407730 digital sound level meter, serial no Z310135 . Leq(A) were measured at different points and hours of the day and night. The average Leq(A) were classified according to localities and compared with WHO standard safety levels. LeqD ranged 71-92dB(A); 42-79dB(A) and 69-90dB(A) in business/ parks, residential and market places respectively. The Night measurements were similar 18dB(A)-56dB(A) and the day-night Leq(A)=77.2dB(A) and 90.4dB(A) for residential and business zones. The night noise levels are satisfactory but the day and day-night levels are above the recommended tolerable values by WHO and therefore urgently call for awareness and legislative regulations.

  20. Noise levels of a track-laying tractor during field operations in the vineyard

    Directory of Open Access Journals (Sweden)

    Pietro Catania

    2013-09-01

    Full Text Available Noise in agriculture is one of the risk factors to be taken into account in the assessment of the health and safety of workers; in particular, it is known that the tractor is a source of high noise. The Italian Low Decree 81/2008 defined the requirements for assessing and managing noise risk identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This paper concerns the analysis of the noise risk arising from the use of a tracklaying tractor during field operations carried out in the vineyard. The objective of this study was to evaluate the noise level that comes close to the ear of the operator driving the tractor measuring the values of equivalent sound level (Leq(A and peak sound pressure (LCpk. We considered four options related to the same tractor coupled with the following tools to perform some farming operations: rototilling, chisel plough, flail mowers and vibro farmer. We considered three test conditions: T1 in flat (slope 0%, T2 uphill and T3 downhill (both 30% slope. The instrument used for the measurements is a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. Each survey lasted 2 minutes, with an interval of measurement equal to 0.5 s. The tests were performed in compliance with the standards ISO 9612 and ISO 9432. The results show that the measured sound levels exceed the limits allowed by the regulations in almost all the test conditions; values exceeding the threshold limit of 80 dB(A were recorded coming up to a maximum value of 92.8 dB(A for flail mowers in test T1. When limits imposed by the regulations are exceeded, the operator is obliged to wear the appropriate Personal Protective Equipment.

  1. The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT

    International Nuclear Information System (INIS)

    Hou, Yang; Xu, Shu; Guo, Wenli; Vembar, Mani; Guo, Qiyong

    2012-01-01

    Aim: To assess the image quality (IQ) of an iterative reconstruction (IR) technique (iDose 4 ) from prospective electrocardiography (ECG)-triggered coronary computed tomography angiography (coronary CTA) on a 256-slice multi-detector CT (MDCT) scanner and determine the optimal dose reduction using IR that can provide IQ comparable to filtered back projection (FBP). Method and materials: 110 consecutive patients (69 men, 41 women; age: 54 ± 10 years) underwent coronary CTA on a 256-slice MDCT (Brilliance iCT, Philips Healthcare). The control group (Group A, n = 21) were scanned using the conventional tube output (120 kVp, 210 mAs) and reconstructed using FBP. The other 4 groups were scanned with the same kVp but successively reduced tube output as follows: B[n = 15]: 125 mAs; C[n = 22]: 105 mAs; D[n = 36]: 84 mAs: E[n = 16]: 65 mAs) and reconstructed using IR levels of L3 (Group B), L4 (Group C) and L5 (Groups D and E), to compensate for the noise increase. All images were reconstructed using the same kernel (XCB). Two radiologists graded IQ in a blinded fashion on a 4-point scale (4 – excellent, 3 – good, 2 – fair and 1 – poor). Quantitative measurements of CT values, image noise and contrast-to-noise (CNR) were measured in each group. A receiver-operating characteristic (ROC) analysis was performed to determine a radiation reduction threshold up to which excellent IQ was maintained. Results: There were no significant differences in objective noise, SNR and CNR values among Groups A, B, C, D, and E (P = 0.14, 0.09, 0.17, respectively). There were no significant differences in the scores of the subjective IQ between Group A, and Groups B, C, D, E (P = 0.23–0.97). Significant differences in image sharpness and study acceptability were observed between groups A and E (P < 0.05). Using the criterion of excellent IQ (score 4), the ROC curve of dose levels and IQ acceptability established a reduction of 60% of tube output (Group D) as optimum cutoff point (AUC

  2. Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector.

    Science.gov (United States)

    Liu, Yu; Leng, Shuai; Michalak, Gregory J; Vrieze, Thomas J; Duan, Xinhui; Qu, Mingliang; Shiung, Maria M; McCollough, Cynthia H; Fletcher, Joel G

    2014-01-01

    To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.

  3. Study on electromagnetic noise reduction in building spaces. Propagation of electromagnetic noise generated by an elevator and its countermeasurement; Kenchiku kukan no denjiha noise hogyo no kenkyu. Elevator kara hasseisuru denjiha noise no denpa jokyo to taisaku ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Y.; Yoshida, K.; Zama, A. [Obayashi Corp., Tokyo (Japan)

    1995-08-10

    With the progress of power-electronics, a inverter has been generally applied to building facility equipment. This equipment go by chapping a current in high frequency, so secondarily generates electromagnetic noise. The characteristics and propagation of electromagnetic noise generated by an elevator machine were measured. From this, it was recognized that high-level spectrum was included in the frequencies under 100kHz, and electromagnetic noise was scattered a wide area on the roof and the highest floor of the building. By intercepting the conductive noise on the motor main distribution line, the area influenced by the noise was restricted to only a small area around the elevator machine room. 4 refs., 8 figs., 2 tabs.

  4. Reduced In-Plane, Low Frequency Helicopter Noise of an Active Flap Rotor

    Science.gov (United States)

    Sim, Ben W.; Janakiram, Ram D.; Barbely, Natasha L.; Solis, Eduardo

    2009-01-01

    Results from a recent joint DARPA/Boeing/NASA/Army wind tunnel test demonstrated the ability to reduce in-plane, low frequency noise of the full-scale Boeing-SMART rotor using active flaps. Test data reported in this paper illustrated that acoustic energy in the first six blade-passing harmonics could be reduced by up to 6 decibels at a moderate airspeed, level flight condition corresponding to advance ratio of 0.30. Reduced noise levels were attributed to selective active flap schedules that modified in-plane blade airloads on the advancing side of the rotor, in a manner, which generated counteracting acoustic pulses that partially offset the negative pressure peaks associated with in-plane, steady thickness noise. These favorable reduced-noise operating states are a strong function of the active flap actuation amplitude, frequency and phase. The associated noise reductions resulted in reduced aural detection distance by up to 18%, but incurred significant vibratory load penalties due to increased hub shear forces. Small reductions in rotor lift-to-drag ratios, of no more than 3%, were also measured

  5. Estimation of Structure-Borne Noise Reduction Effect of Steel Railway Bridge Equipped with Floating Ladder Track and Floating Reinforced-Concrete Deck

    Science.gov (United States)

    Watanabe, Tsutomu; Sogabe, Masamichi; Asanuma, Kiyoshi; Wakui, Hajime

    A number of steel railway bridges have been constructed in Japan. Thin steel members used for the bridges easily tend to vibrate and generate structure-borne noise. Accordingly, the number of constructions of steel railway bridges tends to decrease in the urban areas from a viewpoint of environmental preservation. Then, as a countermeasure against structure-borne noise generated from steel railway bridges, we have developed a new type of the steel railway bridge equipped with a floating-ladder track and a floating reinforced-concrete (RC) deck. As a result of train-running experiment, it became apparent that the new steel railway bridge installed by double floating system has reduced a vibration velocity level by 10.5 dB(A) at main girder web as compared with a steel railway bridge installed by directly fastened track. This reduction effect was achieved by the ladder track and RC deck supported by resilient materials.

  6. Assessment and analysis of noise levels in and around Ib river coalfield, Orissa, India.

    Science.gov (United States)

    Mohapatra, Haraprasad; Goswami, Shreerup

    2012-05-01

    Heavy earth moving machineries, different capacities of dumpers and loaders, blasting and drilling make the mining environment noisy. A study was carried out to assess the noise level in different opencast projects in and around Belpahar and Brajarajnagar areas of Ib river coalfield. Noise assessment was carried out in various residential, commercial and industrial places. The noise levels, especially L(eq) values of different wheel loaders, dumpers, shovel and crusher units were also assessed and were more than permissible limit (90dB) in some of their operating conditions. Sound ressure level measurements while drilling into coal and overburden at Lakhanpur opencast project yielded noise levels (L(eq)) of 81.33 to 96.2 dB. Thus, these L(eq) values of drilling machines in most of the operating conditions were above permissible limit. The average noise intensities (6 a.m.-10 p.m.: 51.6-60.875dB and 10 p.m.-6 a.m.: 42.6-49.8dB) and L(eq) values (6 a.m.-10 p.m.: 50.9-67.0dB and 10 p.m.-6 a.m.: 40.8-53.3dB) during both day and night time of the residential areas around the Ib river coalfield were in close proximity or beyond the permissible limit. The L(eq) values at some of the commercial and industrial places were beyond (6 a.m.-10 p.m.: 61.6-88.3 dB and 10 p.m.-6 a.m.: 55.4-64.8dB) permissible limit. However, in most of the cases, the L(max) noise values were more (6 a.m.-10 p.m.: 68.5-91.4 dB and 10 p.m.-6 a.m.: 69.3-76.4dB) than the permissible limit. Analysis of variance was also computed for heavy earth moving machineries in different operating conditions and also for different residential, commercial and industrial places to infer the level of significance. The difference of noise intensity produced by different wheel loaders at Lakhanpur and Lilari opencast projects, drilling machines at Lakhanpur opencast project, 50 tons capacity dumpers at various conditions of Ib river coalfield within the same operating condition was significant at both 5% and 1% levels

  7. Experimental Results on the Level Crossing Intervals of the Phase of Sine Wave Plus Noise

    Science.gov (United States)

    Youssef, Neji; Munakata, Tsutomu; Mimaki, Tadashi

    1993-03-01

    Experimental study was made on the level crossing intervals of a phase process of a sine wave plus narrow-band Gaussian noise. Since successive level crossings of phase do not necessarily occur alternately in the upward and downward direction due to the phase jump beyond 2π, the usual definitions of the probability densities of the level crossing intervals for continuous random processes are not applicable in the case of the phase process. Therefore, the probability densities of level crossing intervals of phase process are newly defined. Measurements of these densities were performed for noise having lowpass spectra of Gaussian and 7th order Butterworth types. Results are given for various values of the signal-to-noise power ratio and of the crossing level, and compared with corresponding approximation developed under the assumption of quasi-independence. The validity of the assumption depends on the spectrum shape of the noise.

  8. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective

    International Nuclear Information System (INIS)

    Brady, S. L.; Yee, B. S.; Kaufman, R. A.

    2012-01-01

    Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR™) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR™. Empirically derived dose reduction limits were established for ASiR™ for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metric was tested using the ACR CT phantom with 0%–100% ASiR™ blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR™ implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR™ reconstruction to maintain noise equivalence of the 0% ASiR™ image. Results: The ASiR™ algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR™ reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR™ presented a more smoothed appearance than the pre-ASiR™ 100% FBP image. Finally, relative to non-ASiR™ images with 100% of standard dose across the

  9. Effect of Microjet Injection on Supersonic Jet Noise

    Science.gov (United States)

    Zaman, K. B. M. Q.; Podboy, G. G.

    2010-01-01

    The effect of microjet (jet) injection on the noise from supersonic jets is investigated. Three convergent-divergent (C-D) nozzles and one convergent nozzle, all having the same exit diameters, are used in the study. The jets are injected perpendicular to the primary jet close to the nozzle lip from six equally-spaced ports having a jet-to-primary-jet diameter ratio of 0.0054. Effects in the over-expanded, fully expanded as well as underexpanded flow regimes are explored. Relative to the effect on subsonic jets, larger reductions in the overall sound pressure level (OASPL) are achieved in most supersonic conditions. The largest reductions are typically associated with suppression of screech and transonic tones. For a shock-free, fully expanded case, the OASPL reductions achieved are comparable to that in the subsonic case; the same correlation, found for subsonic jet noise reduction at shallow observation angle, applies.

  10. Noise level in intensive care units of a public university hospital in Santa Marta (Colombia).

    Science.gov (United States)

    Garrido Galindo, A P; Camargo Caicedo, Y; Vélez-Pereira, A M

    2016-10-01

    To evaluate the noise level in adult, pediatric and neonatal intensive care units of a university hospital in the city of Santa Marta (Colombia). A descriptive, observational, non-interventional study with follow-up over time was carried out. Continuous sampling was conducted for 20 days for each unit using a type i sound level meter, filter frequency in A weighting and Fast mode. We recorded the maximum values, the 90th percentile as background noise, and the continuous noise level. The mean hourly levels in the adult unit varied between 57.40±1.14-63.47±2.13dBA, with a maximum between 71.55±2.32-77.22±1.94dBA, and a background noise between 53.51±1.16-60.26±2.10dBA; in the pediatric unit the mean hourly levels varied between 57.07±3.07-65.72±2.46dBA, with a maximum of 68.69±3.57-79.06±2.34dBA, and a background noise between 53.33±3.54-61.96±2.85dBA; the neonatal unit in turn presented mean hourly values between 59.54±2.41-65.33±1.77dBA, with a maximum value between 67.20±2.13-77.65±3.74dBA, and a background noise between 55.02±2.03-58.70±1.95dBA. Analysis of variance revealed a significant difference between the hourly values and between the different units, with the time of day exhibiting a greater influence. The type of unit affects the noise levels in intensive care units, the pediatric unit showing the highest values and the adult unit the lowest values. However, the parameter exerting the greatest influence upon noise level is the time of day, with higher levels in the morning and evening, and lower levels at night and in the early morning. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  11. Rat hippocampal alterations could underlie behavioral abnormalities induced by exposure to moderate noise levels.

    Science.gov (United States)

    Uran, S L; Aon-Bertolino, M L; Caceres, L G; Capani, F; Guelman, L R

    2012-08-30

    Noise exposure is known to affect auditory structures in living organisms. However, it should not be ignored that many of the effects of noise are extra-auditory. Previous findings of our laboratory demonstrated that noise was able to induce behavioral alterations that are mainly related to the cerebellum (CE) and the hippocampus (HC). Therefore, the aim of this work was to reveal new data about the vulnerability of developing rat HC to moderate noise levels through the assessment of potential histological changes and hippocampal-related behavioral alterations. Male Wistar rats were exposed to noise (95-97 dB SPL, 2h daily) either for 1 day (acute noise exposure, ANE) or between postnatal days 15 and 30 (sub-acute noise exposure, SANE). Hippocampal histological evaluation as well as short (ST) and long term (LT) habituation and recognition memory assessments were performed. Results showed a mild disruption in the different hippocampal regions after ANE and SANE schemes, along with significant behavioral abnormalities. These data suggest that exposure of developing rats to noise levels of moderate intensity is able to trigger changes in the HC, an extra-auditory structure of the Central Nervous System (CNS), that could underlie the observed behavioral effects. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Predictive modelling of noise level generated during sawing of rocks ...

    Indian Academy of Sciences (India)

    This paper presents an experimental and statistical study on noise level generated .... hardness were determined according to related ISRM (1981) suggested methods. Thin section ..... tistical Package for the Social Sciences). Additionally, the ...

  13. The Feasibility of Noise Control in a Soft Drink Plant

    Directory of Open Access Journals (Sweden)

    Fouladi Dehaghi

    2016-03-01

    Full Text Available Background “Noise” can be defined as any unwanted sound. Soft drink plants, which produce the raw materials used in most carbonated beverage factories, are sources of noise. Objectives This study investigated the noise pollution present in a soft drink CO2 gas injection plant, in order to present noise control measures. Materials and Methods The instructions specified by the canadian center for occupational health and safety (CCOHS were followed during the noise study, and a sound level meter, CEL.450 calibrated with CEL-110.2 based on ISO-9612 methods, was used to record the sound pressure level (SPL at each grid point. SPL was determined in weighting scales A and C. and a noise survey map of equivalent SPLs was drawn for each part. Each part of the floor area of the soft drink factory where SPL exceeded 85 dBA was identified from the noise survey map to determine the causes of high levels of noise. In order to reduce noise level in each part, the absorption coefficient, transmission loss, and noise reduction rate were calculated in the proposed control area. Results According to the study results, noise levels in a CO2 plant’s house and control room ranged from 88 to 102 dB and 79 to 82 dB (A, respectively. In order to reduce the amount of emitted noise in the CO2 plant house and control room, a noise control plan was implemented in each part of the facility; it was met with effective results. Conclusions The findings of this investigation have clearly revealed that plant workers are at risk of developing noise-induced hearing loss. However, after the implementation of a noise control plan in each part of the facility, the noise dose received by workers has significantly decreased. The need to implement a noise conservation program was established.

  14. Determination of the optimal dose reduction level via iterative reconstruction using 640-slice volume chest CT in a pig model.

    Directory of Open Access Journals (Sweden)

    Xingli Liu

    Full Text Available To determine the optimal dose reduction level of iterative reconstruction technique for paediatric chest CT in pig models.27 infant pigs underwent 640-slice volume chest CT with 80kVp and different mAs. Automatic exposure control technique was used, and the index of noise was set to SD10 (Group A, routine dose, SD12.5, SD15, SD17.5, SD20 (Groups from B to E to reduce dose respectively. Group A was reconstructed with filtered back projection (FBP, and Groups from B to E were reconstructed using iterative reconstruction (IR. Objective and subjective image quality (IQ among groups were compared to determine an optimal radiation reduction level.The noise and signal-to-noise ratio (SNR in Group D had no significant statistical difference from that in Group A (P = 1.0. The scores of subjective IQ in Group A were not significantly different from those in Group D (P>0.05. There were no obvious statistical differences in the objective and subjective index values among the subgroups (small, medium and large subgroups of Group D. The effective dose (ED of Group D was 58.9% lower than that of Group A (0.20±0.05mSv vs 0.48±0.10mSv, p <0.001.In infant pig chest CT, using iterative reconstruction can provide diagnostic image quality; furthermore, it can reduce the dosage by 58.9%.

  15. Children's speech recognition and loudness perception with the Desired Sensation Level v5 Quiet and Noise prescriptions.

    Science.gov (United States)

    Crukley, Jeffery; Scollie, Susan D

    2012-12-01

    To determine whether Desired Sensation Level (DSL) v5 Noise is a viable hearing instrument prescriptive algorithm for children, in comparison with DSL v5 Quiet. In particular, the authors compared children's performance on measures of consonant recognition in quiet, sentence recognition in noise, and loudness perception when fitted with DSL v5 Quiet and Noise. Eleven children (ages 8 to 17 years) with stable, congenital sensorineural hearing losses participated in the study. Participants were fitted bilaterally to DSL v5 prescriptions with behind-the-ear hearing instruments. The order of prescription was counterbalanced across participants. Repeated measures analysis of variance was used to compare performance between prescriptions. Use of the Noise prescription resulted in a significant decrease in consonant perception in Quiet with low-level input, but no difference with average-level input. There was no significant difference in sentence-in-noise recognition between the two prescriptions. Loudness ratings for input levels above 72 dB SPL were significantly lower with the noise prescription. Average-level consonant recognition in quiet was preserved and aversive loudness was alleviated by the Noise prescription relative to the quiet prescription, which suggests that the DSL v5 Noise prescription may be an effective approach to managing the nonquiet listening needs of children with hearing loss.

  16. Evaluation of the environmental noise levels in Abuja Municipality ...

    African Journals Online (AJOL)

    Objectives: To assess the equivalent noise level (Leq) in Abuja municipality and promote a simple method for regular assessment of Leq within our environment. Methods: This is a cross-sectional community based study of the environmental Leq of Abuja municipality conducted between January 2014 and January 2016.

  17. The Dornier 328 Acoustic Test Cell (ATC) for interior noise tests and selected test results

    Science.gov (United States)

    Hackstein, H. Josef; Borchers, Ingo U.; Renger, Klaus; Vogt, Konrad

    1992-01-01

    To perform acoustic studies for achieving low noise levels for the Dornier 328, an acoustic test cell (ATC) of the Dornier 328 has been built. The ATC consists of a fuselage section, a realistic fuselage suspension system, and three exterior noise simulation rings. A complex digital 60 channel computer/amplifier noise generation system as well as multichannel digital data acquisition and evaluation system have been used. The noise control tests started with vibration measurements for supporting acoustic data interpretation. In addition, experiments have been carried out on dynamic vibration absorbers, the most important passive noise reduction measure for low frequency propeller noise. The design and arrangement of the current ATC are presented. Furthermore, exterior noise simulation as well as data acquisition are explained. The most promising results show noise reduction due to synchrophasing and dynamic vibration absorbers.

  18. Reduction of MRI acoustic noise achieved by manipulation of scan parameters – A study using veterinary MR sequences

    International Nuclear Information System (INIS)

    Baker, Martin A.

    2013-01-01

    Sound pressure levels were measured within an MR scan room for a range of sequences employed in veterinary brain scanning, using a test phantom in an extremity coil. Variation of TR and TE, and use of a quieter gradient mode (‘whisper’ mode) were evaluated to determine their effect on sound pressure levels (SPLs). Use of a human head coil and a human brain sequence was also evaluated. Significant differences in SPL were achieved for T2, T1, T2* gradient echo and VIBE sequences by varying TR or TE, or by selecting the ‘whisper’ gradient mode. An appreciable reduction was achieved for the FLAIR sequence. Noise levels were not affected when a head coil was used in place of an extremity coil. Due to sequence parameters employed, veterinary patients and anaesthetists may be exposed to higher sound levels than those experienced in human MR examinations. The techniques described are particularly valuable in small animal MR scanning where ear protection is not routinely provided for the patient.

  19. In vitro comparison of noise levels produced by different CPAP generators.

    Science.gov (United States)

    Kirchner, Lieselotte; Wald, Martin; Jeitler, Valerie; Pollak, Arnold

    2012-01-01

    Minimization of noise exposure is an important aim of modern neonatal intensive care medicine. Binasal continuous positive airway pressure (CPAP) generators are among the most important sources of continuous noise in neonatal wards. The aim of this study was to find out which CPAP generator creates the least noise. In an experimental setup, two jet CPAP generators (Infant Flow® generator and MediJet®) and two conventional CPAP generators (Bubble CPAP® and Baby Flow®) were compared. Noise production was measured in decibels in an A-weighted scale [dB(A)] in a closed incubator at 2 mm lateral distance from the end of the nasal prongs. Reproduction of constant airway pressure and air leak was achieved by closure of the nasal prongs with a type of adhesive tape that is semipermeable to air. The noise levels produced by the four generators were significantly different (p CPAP® and 55 dB(A) for the Baby Flow®. Conventional CPAP generators work more quietly than the currently available jet CPAP generators. Copyright © 2011 S. Karger AG, Basel.

  20. GPR random noise reduction using BPD and EMD

    Science.gov (United States)

    Ostoori, Roya; Goudarzi, Alireza; Oskooi, Behrooz

    2018-04-01

    Ground-penetrating radar (GPR) exploration is a new high-frequency technology that explores near-surface objects and structures accurately. The high-frequency antenna of the GPR system makes it a high-resolution method compared to other geophysical methods. The frequency range of recorded GPR is so wide that random noise recording is inevitable due to acquisition. This kind of noise comes from unknown sources and its correlation to the adjacent traces is nearly zero. This characteristic of random noise along with the higher accuracy of GPR system makes denoising very important for interpretable results. The main objective of this paper is to reduce GPR random noise based on pursuing denoising using empirical mode decomposition. Our results showed that empirical mode decomposition in combination with basis pursuit denoising (BPD) provides satisfactory outputs due to the sifting process compared to the time-domain implementation of the BPD method on both synthetic and real examples. Our results demonstrate that because of the high computational costs, the BPD-empirical mode decomposition technique should only be used for heavily noisy signals.

  1. Development of a Quantitative Methodology to Assess the Impacts of Urban Transport Interventions and Related Noise on Well-Being

    Directory of Open Access Journals (Sweden)

    Matthias Braubach

    2015-05-01

    Full Text Available Well-being impact assessments of urban interventions are a difficult challenge, as there is no agreed methodology and scarce evidence on the relationship between environmental conditions and well-being. The European Union (EU project “Urban Reduction of Greenhouse Gas Emissions in China and Europe” (URGENCHE explored a methodological approach to assess traffic noise-related well-being impacts of transport interventions in three European cities (Basel, Rotterdam and Thessaloniki linking modeled traffic noise reduction effects with survey data indicating noise-well-being associations. Local noise models showed a reduction of high traffic noise levels in all cities as a result of different urban interventions. Survey data indicated that perception of high noise levels was associated with lower probability of well-being. Connecting the local noise exposure profiles with the noise-well-being associations suggests that the urban transport interventions may have a marginal but positive effect on population well-being. This paper also provides insight into the methodological challenges of well-being assessments and highlights the range of limitations arising from the current lack of reliable evidence on environmental conditions and well-being. Due to these limitations, the results should be interpreted with caution.

  2. Development of a quantitative methodology to assess the impacts of urban transport interventions and related noise on well-being.

    Science.gov (United States)

    Braubach, Matthias; Tobollik, Myriam; Mudu, Pierpaolo; Hiscock, Rosemary; Chapizanis, Dimitris; Sarigiannis, Denis A; Keuken, Menno; Perez, Laura; Martuzzi, Marco

    2015-05-26

    Well-being impact assessments of urban interventions are a difficult challenge, as there is no agreed methodology and scarce evidence on the relationship between environmental conditions and well-being. The European Union (EU) project "Urban Reduction of Greenhouse Gas Emissions in China and Europe" (URGENCHE) explored a methodological approach to assess traffic noise-related well-being impacts of transport interventions in three European cities (Basel, Rotterdam and Thessaloniki) linking modeled traffic noise reduction effects with survey data indicating noise-well-being associations. Local noise models showed a reduction of high traffic noise levels in all cities as a result of different urban interventions. Survey data indicated that perception of high noise levels was associated with lower probability of well-being. Connecting the local noise exposure profiles with the noise-well-being associations suggests that the urban transport interventions may have a marginal but positive effect on population well-being. This paper also provides insight into the methodological challenges of well-being assessments and highlights the range of limitations arising from the current lack of reliable evidence on environmental conditions and well-being. Due to these limitations, the results should be interpreted with caution.

  3. Light aircraft sound transmission studies - Noise reduction model

    Science.gov (United States)

    Atwal, Mahabir S.; Heitman, Karen E.; Crocker, Malcolm J.

    1987-01-01

    Experimental tests conducted on the fuselage of a single-engine Piper Cherokee light aircraft suggest that the cabin interior noise can be reduced by increasing the transmission loss of the dominant sound transmission paths and/or by increasing the cabin interior sound absorption. The validity of using a simple room equation model to predict the cabin interior sound-pressure level for different fuselage and exterior sound field conditions is also presented. The room equation model is based on the sound power flow balance for the cabin space and utilizes the measured transmitted sound intensity data. The room equation model predictions were considered good enough to be used for preliminary acoustical design studies.

  4. VOLUNTARY NOISE MAPPING FOR SMART CITY

    Directory of Open Access Journals (Sweden)

    V. Poslončec-Petrić

    2016-09-01

    Full Text Available One of the main concept objectives of smart cities is to create a quality living environment that is long-term sustainable and economically justified. In that context, modern cities are aware of the exposure to various forms of physical and non-physical pollution that needs to be remediated, eliminated or reduced. To achieve that it is necessary to quality determine the sources and reasons of each pollution. The most prominent examples of physical pollution that affects the quality of life of citizens in cities are light and noise pollution. Noise pollution or noise, is mostly the consequence of road and rail traffic in cities and it directly affects the health of citizens. Traffic control, reduction of peak congestion, dispersion and traffic redirection or building protective barriers, are ways that cities use to reduce the amount of noise or its effects. To make these measures efficient it is necessary to obtain the information related to the level of noise in certain areas, streets, cities. To achieve this, smart cities use noise mapping. The city of Zagreb since 2012, participates in the i-SCOPE project (interoperable Smart City services trough Open Platform for urban Ecosystems. i-SCOPE delivers an open platform on top of which it develops, three "smart city" services: optimization of energy consumption through a service for accurate assessment of solar energy potential and energy loss at building level, environmental monitoring through a real-time environmental noise mapping service leveraging citizen's involvement will who act as distributed sensors city-wide measuring noise levels through an application on their mobile phones and improved inclusion and personal mobility of aging and diversely able citizens through an accurate personal routing service. The students of Faculty of Geodesy University of Zagreb, who enrolled in the course Thematic Cartography, were actively involved in the voluntary data acquisition in order to monitor the

  5. Voluntary Noise Mapping for Smart City

    Science.gov (United States)

    Poslončec-Petrić, V.; Vuković, V.; Frangeš, S.; Bačić, Ž.

    2016-09-01

    One of the main concept objectives of smart cities is to create a quality living environment that is long-term sustainable and economically justified. In that context, modern cities are aware of the exposure to various forms of physical and non-physical pollution that needs to be remediated, eliminated or reduced. To achieve that it is necessary to quality determine the sources and reasons of each pollution. The most prominent examples of physical pollution that affects the quality of life of citizens in cities are light and noise pollution. Noise pollution or noise, is mostly the consequence of road and rail traffic in cities and it directly affects the health of citizens. Traffic control, reduction of peak congestion, dispersion and traffic redirection or building protective barriers, are ways that cities use to reduce the amount of noise or its effects. To make these measures efficient it is necessary to obtain the information related to the level of noise in certain areas, streets, cities. To achieve this, smart cities use noise mapping. The city of Zagreb since 2012, participates in the i-SCOPE project (interoperable Smart City services trough Open Platform for urban Ecosystems). i-SCOPE delivers an open platform on top of which it develops, three "smart city" services: optimization of energy consumption through a service for accurate assessment of solar energy potential and energy loss at building level, environmental monitoring through a real-time environmental noise mapping service leveraging citizen's involvement will who act as distributed sensors city-wide measuring noise levels through an application on their mobile phones and improved inclusion and personal mobility of aging and diversely able citizens through an accurate personal routing service. The students of Faculty of Geodesy University of Zagreb, who enrolled in the course Thematic Cartography, were actively involved in the voluntary data acquisition in order to monitor the noise in real time

  6. A direct method for calculating instrument noise levels in side-by-side seismometer evaluations

    Science.gov (United States)

    Holcomb, L. Gary

    1989-01-01

    The subject of determining the inherent system noise levels present in modem broadband closed loop seismic sensors has been an evolving topic ever since closed loop systems became available. Closed loop systems are unique in that the system noise can not be determined via a blocked mass test as in older conventional open loop seismic sensors. Instead, most investigators have resorted to performing measurements on two or more systems operating in close proximity to one another and to analyzing the outputs of these systems with respect to one another to ascertain their relative noise levels.The analysis of side-by-side relative performance is inherently dependent on the accuracy of the mathematical modeling of the test configuration. This report presents a direct approach to extracting the system noise levels of two linear systems with a common coherent input signal. The mathematical solution to the problem is incredibly simple; however the practical application of the method encounters some difficulties. Examples of expected accuracies are presented as derived by simulating real systems performance using computer generated random noise. In addition, examples of the performance of the method when applied to real experimental test data are shown.

  7. Noiseonomics: the relationship between ambient noise levels in the sea and global economic trends.

    Science.gov (United States)

    Frisk, George V

    2012-01-01

    In recent years, the topic of noise in the sea and its effects on marine mammals has attracted considerable attention from both the scientific community and the general public. Since marine mammals rely heavily on acoustics as a primary means of communicating, navigating, and foraging in the ocean, any change in their acoustic environment may have an impact on their behavior. Specifically, a growing body of literature suggests that low-frequency, ambient noise levels in the open ocean increased approximately 3.3 dB per decade during the period 1950-2007. Here we show that this increase can be attributed primarily to commercial shipping activity, which in turn, can be linked to global economic growth. As a corollary, we conclude that ambient noise levels can be directly related to global economic conditions. We provide experimental evidence supporting this theory and discuss its implications for predicting future noise levels based on global economic trends.

  8. Effects of a traffic noise background on judgements of aircraft noise

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1974-01-01

    A study was conducted in which subjects judged aircraft noises in the presence of road traffic background noise. Two different techniques for presenting the background noises were evaluated. For one technique, the background noise was continuous over the whole of a test session. For the other, the background noise was changed with each aircraft noise. A range of aircraft noise levels and traffic noise levels were presented to simulate typical indoor levels.

  9. Effect of background noise on neuronal coding of interaural level difference cues in rat inferior colliculus.

    Science.gov (United States)

    Mokri, Yasamin; Worland, Kate; Ford, Mark; Rajan, Ramesh

    2015-07-01

    Humans can accurately localize sounds even in unfavourable signal-to-noise conditions. To investigate the neural mechanisms underlying this, we studied the effect of background wide-band noise on neural sensitivity to variations in interaural level difference (ILD), the predominant cue for sound localization in azimuth for high-frequency sounds, at the characteristic frequency of cells in rat inferior colliculus (IC). Binaural noise at high levels generally resulted in suppression of responses (55.8%), but at lower levels resulted in enhancement (34.8%) as well as suppression (30.3%). When recording conditions permitted, we then examined if any binaural noise effects were related to selective noise effects at each of the two ears, which we interpreted in light of well-known differences in input type (excitation and inhibition) from each ear shaping particular forms of ILD sensitivity in the IC. At high signal-to-noise ratios (SNR), in most ILD functions (41%), the effect of background noise appeared to be due to effects on inputs from both ears, while for a large percentage (35.8%) appeared to be accounted for by effects on excitatory input. However, as SNR decreased, change in excitation became the dominant contributor to the change due to binaural background noise (63.6%). These novel findings shed light on the IC neural mechanisms for sound localization in the presence of continuous background noise. They also suggest that some effects of background noise on encoding of sound location reported to be emergent in upstream auditory areas can also be observed at the level of the midbrain. © 2015 The Authors. European Journal of Neuroscience published by Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  10. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    Science.gov (United States)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen; Falk, Tiago H.; Voix, Jérémie

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12 different talkers at 5 different distances in 3…

  11. Hearing impairment among workers exposed to excessive levels of noise in ginning industries

    Directory of Open Access Journals (Sweden)

    Kamalesh J Dube

    2011-01-01

    Full Text Available Cotton ginning workers have a risk of hearing loss due to excessive noise levels at the workplace environment. In this study, estimates of typical sound levels prevailing at the workplace environment and its effects on hearing ability of the exposed workers were made among cotton ginning workers. Data on self-reported health status was collected by a questionnaire survey at 10 cotton ginning industries located at Jalgaon district of Maharashtra state, India. The cotton ginning workers were exposed to continuous noise levels between 89 and 106 dBA. The hearing ability of the subjects was accessed by pure tone audiometry. The results of audiometry show mild, moderate and moderately severe degree of hearing impairment among the cotton ginning workers. The data generated during the study show that hearing loss was significantly associated with period of exposure to the workplace noise (P <0.0001. The prevalence of audiometric hearing impairment defined as a threshold average greater than 25 dB hearing level was 96% for binaural low-frequency average, 97% for binaural mid frequency average and 94% for binaural high-frequency average in the cotton ginning workers. We recommend the compulsory use of personal protective equipment like ear plug by the cotton ginning workers at the workplace environment. A regular maintenance of ginning and pressing machineries will avoid the emission of excessive noise at the workplace environment of cotton gins. A regular periodic medical examination is necessary to measure the impact of workplace noise on the health of cotton ginning workers.

  12. Noise level and MPEG-2 encoder statistics

    Science.gov (United States)

    Lee, Jungwoo

    1997-01-01

    Most software in the movie and broadcasting industries are still in analog film or tape format, which typically contains random noise that originated from film, CCD camera, and tape recording. The performance of the MPEG-2 encoder may be significantly degraded by the noise. It is also affected by the scene type that includes spatial and temporal activity. The statistical property of noise originating from camera and tape player is analyzed and the models for the two types of noise are developed. The relationship between the noise, the scene type, and encoder statistics of a number of MPEG-2 parameters such as motion vector magnitude, prediction error, and quant scale are discussed. This analysis is intended to be a tool for designing robust MPEG encoding algorithms such as preprocessing and rate control.

  13. Noise-induced annoyance from transportation noise: short-term responses to a single noise source in a laboratory.

    Science.gov (United States)

    Kim, Jaehwan; Lim, Changwoo; Hong, Jiyoung; Lee, Soogab

    2010-02-01

    An experimental study was performed to compare the annoyances from civil-aircraft noise, military-aircraft noise, railway noise, and road-traffic noise. Two-way within-subjects designs were applied in this research. Fifty-two subjects, who were naive listeners, were given various stimuli with varying levels through a headphone in an anechoic chamber. Regardless of the frequency weighting network, even under the same average energy level, civil-aircraft noise was the most annoying, followed by military-aircraft noise, railway noise, and road-traffic noise. In particular, penalties in the time-averaged, A-weighted sound level (TAL) of about 8, 5, and 5 dB, respectively, were found in the civil-aircraft, military-aircraft, and railway noises. The reason could be clarified through the high-frequency component and the variability in the level. When people were exposed to sounds with the same maximum A-weighted level, a railway bonus of about 3 dB was found. However, transportation noise has been evaluated by the time-averaged A-weighted level in most countries. Therefore, in the present situation, the railway bonus is not acceptable for railway vehicles with diesel-electric engines.

  14. Electrochemical noise measurements under pressurized water reactor conditions

    International Nuclear Information System (INIS)

    Van Nieuwenhove, R.

    2000-01-01

    Electrochemical potential noise measurements on sensitized stainless steel pressure tubes under pressurized water reactor (PWR) conditions were performed for the first time. Very short potential spikes, believed to be associated to crack initiation events, were detected when stressing the sample above the yield strength and increased in magnitude until the sample broke. Sudden increases of plastic deformation, as induced by an increased tube pressure, resulted in slower, high-amplitude potential transients, often accompanied by a reduction in noise level

  15. Low frequency noise in semiconductor detectors

    International Nuclear Information System (INIS)

    Stojanovic, M.; Marjanovic, N.

    1998-01-01

    Noise characteristics of surface-barrier detectors based on Au contacts on n-Si were measured and analyzed. The metal layers were deposited by evaporation to 40-100 nm thickness. Standard surface-barrier detectors based on Au/Si structures are known to have favorable characteristics, but they tend to degrade with aging and under severe working conditions. Degradation is particularly related to the increase in noise level, leakage current and the reduction of detector efficiency and resolution. Therefore, practical applications of surface-barrier detectors demand their constant upgrading. Improvements of detector properties are concentrated mainly on the front surface and front (rectifying) contact. The aim was to improve the noise characteristics of the surface-barrier structures and retain the favorable detector properties of the Au/Si system. (authors)

  16. Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels.

    Science.gov (United States)

    Riffel, Philipp; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Morelli, John N; Schmidt, Bernhard; Schoenberg, Stefan O; Henzler, Thomas

    2016-04-01

    Calculated monoenergetic ultra-low keV datasets did not lead to improved contrast-to-noise ratio (CNR) due to the dramatic increase in image noise. The aim of the present study was to evaluate the objective image quality of ultra-low keV monoenergetic images (MEIs) calculated from carotid DECT angiography data with a new monoenergetic imaging algorithm using a frequency-split technique. 20 patients (12 male; mean age 53±17 years) were retrospectively analyzed. MEIs from 40 to 120 keV were reconstructed using the monoenergetic split frequency approach (MFSA). Additionally MEIs were reconstructed for 40 and 50 keV using a conventional monoenergetic (CM) software application. Signal intensity, noise, signal-to-noise ratio (SNR) and CNR were assessed in the basilar, common, internal carotid arteries. Ultra-low keV MEIs at 40 keV and 50 keV demonstrated highest vessel attenuation, significantly greater than those of the polyenergetic images (PEI) (all p-values 0.05). Thus MEIs with MFSA showed significantly higher SNR and CNR compared to MEIs with CM. Combining the lower spatial frequency stack for contrast at low keV levels with the high spatial frequency stack for noise at high keV levels (frequency-split technique) leads to improved image quality of ultra-low keV monoenergetic DECT datasets when compared to previous monoenergetic reconstruction techniques without the frequency-split technique. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Effects of traffic noise on tree frog stress levels, immunity, and color signaling.

    Science.gov (United States)

    Troïanowski, Mathieu; Mondy, Nathalie; Dumet, Adeline; Arcanjo, Caroline; Lengagne, Thierry

    2017-10-01

    During the last decade, many studies have focused on the detrimental effects of noise pollution on acoustic communication. Surprisingly, although it is known that noise exposure strongly influences health in humans, studies on wildlife remain scarce. In order to gain insight into the consequences of traffic noise exposure, we experimentally manipulated traffic noise exposure as well as the endocrine status of animals to investigate physiological and phenotypic consequences of noise pollution in an anuran species. We showed that noise exposure increased stress hormone level and induced an immunosuppressive effect. In addition, both traffic noise exposure and stress hormone application negatively impacted H. arborea vocal sac coloration. Moreover, our results suggest profound changes in sexual selection processes because the best quality males with initial attractive vocal sac coloration were the most impacted by noise. Hence, our study suggests that the recent increases in anthropogenic noise worldwide might affect a broader range of animal species than previously thought, because of alteration of visual signals and immunity. Generalizing these results to other taxa is crucial for the conservation of biodiversity in an increasingly noisy world. © 2017 Society for Conservation Biology.

  18. High Velocity Jet Noise Source Location and Reduction. Task 6. Noise Abatement Nozzle Design Guide.

    Science.gov (United States)

    1979-04-01

    the Conical Nozzle 255 on the Bertin Aerotrain . xvi ji4 ’ . _______ p .. LIST OF ILLUSTRATIONS (Continued) Figure Page D-37. Predicted and Measured...Moving-Frame Noise from the 256 Conical Nozzle on the Bertin Aerotrain . D-38. Predicted and Measured Static Noise from the 104-Tube 257 Nozzle on the...Bertin Aerotrain . D-39. Predicted and Measured Moving-Frame Noise from the 104- 258 Tube Nozzle on the Bertin Aerotrain . D-40. Relative Velocity Index m

  19. Efficacy and mode of action of a noise-sensor light alarm to decrease noise in the pediatric intensive care unit: a prospective, randomized study.

    Science.gov (United States)

    Jousselme, Chloé; Vialet, Renaud; Jouve, Elisabeth; Lagier, Pierre; Martin, Claude; Michel, Fabrice

    2011-03-01

    To determine whether a sound-activated light-alarm device could reduce the noise in the central area of our pediatric intensive care unit and to determine whether this reduction was significant enough to decrease the noise that could be perceived by a patient located in a nearby room. The secondary objective was to determine the mode of action of the device. In a 16-bed pediatric and neonatal intensive care unit, a large and clearly noticeable sound-activated light device was set in the noisiest part of the central area of our unit, and noise measurements were made in the central area and in a nearby room. In a prospective, quasi-experimental design, sound levels were compared across three different situations--no device present, device present and turned on, and device present but turned off--and noise level measurements were made over a total of 18 days. None. Setting a sound-activated light device on or off. When the device was present, the noise was about 2 dB lower in the central area and in a nearby room, but there was no difference in noise level with the device turned on vs. turned off. The noise decrease in the central area was of limited importance but was translated in a nearby room. The sound-activated light device did not directly decrease noise when turned on, but repetition of the visual signal throughout the day raised staff awareness of noise levels over time.

  20. Comparison of the Effect of Noise Levels on Stress Response in Two Different Operation Groups in an Orthopedic Surgery Room

    Directory of Open Access Journals (Sweden)

    Hasibe Baytan Yildiz

    2016-09-01

    Full Text Available Aim: The aim of this randomized, single-blinded study was to evaluate the effects of noise on hemodynamic and neuroendocrine stress response by measuring the level of noise in the surgery rooms of patients undergoing knee operations under neuroaxial anesthesia. Gerec ve Yontem: We compared patient responses from two groups of patients: those undergoing knee operations in a surgery room where the noise level (measured in decibels is high, and those undergoing meniscus operations in a surgery room with lower noise levels. The STAI, the State-Trait Anxiety Inventory (STAI-1, and the anxiety test (STAI-2wereperformed at preoperative and postoperative periods. 20 ml of blood sample was taken for basal, intraoperative 30th minute, and postoperative 1st hour measurements. Systolic, diastolic, and mean arterial blood pressures were found to be higher in the high noise level group. ACTH levels were increased during the early postoperative period and became normal during the late postoperative period in the high noise level group whereas ACTH levels were significantly decreased in the low-noise level group. Basal cortisol levels were significantly higher in the high noise level group. HCRP, an inflammatory response mediator was found to be decreased in both groups. Early and late blood glucose levels were significantly higher in the high noise group. There was a greater increase in early and late blood glucose levels in the high noise group. In the postoperative period, although the state-trait anxiety inventory (STAI-2 levels being higher in patients subject to noisier environment determines how people feel independent of the conditions and state they are in, this result made us consider that the noise the patients were subjected to in the intraoperative period may cause a stress response. Discussion: As a result we believe that standard noise levels should be achieved by reducing the factors causing high noise levels in the operating room. This will