  1. Infrared skin damage thresholds from 1319-nm continuous-wave laser exposures

    Science.gov (United States)

    Oliver, Jeffrey W.; Vincelette, Rebecca; Noojin, Gary D.; Clark, Clifton D.; Harbert, Corey A.; Schuster, Kurt J.; Shingledecker, Aurora D.; Kumru, Semih S.; Maughan, Justin; Kitzis, Naomi; Buffington, Gavin D.; Stolarski, David J.; Thomas, Robert J.

    2013-12-01

    A series of experiments were conducted in vivo using Yucatan miniature pigs (Sus scrofa domestica) to determine thermal damage thresholds to the skin from 1319-nm continuous-wave Nd:YAG laser irradiation. Experiments employed exposure durations of 0.25, 1.0, 2.5, and 10 s and beam diameters of ˜0.6 and 1 cm. Thermal imagery data provided a time-dependent surface temperature response from the laser. A damage endpoint of fifty percent probability of a minimally visible effect was used to determine threshold for damage at 1 and 24 h postexposure. Predicted thermal response and damage thresholds are compared with a numerical model of optical-thermal interaction. Resultant trends with respect to exposure duration and beam diameter are compared with current standardized exposure limits for laser safety. Mathematical modeling agreed well with experimental data, predicting that though laser safety standards are sufficient for exposures <10 s, they may become less safe for very long exposures.

  2. Histologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser.

    Science.gov (United States)

    Mordon, Serge; Eymard-Maurin, Anne Françoise; Wassmer, Benjamin; Ringot, Jean

    2007-01-01

    The use of the laser as an auxiliary tool has refined the traditional technique for lipoplasty. During laser lipolysis, the interaction between the laser and the fat produced direct cellular destruction before the suction, reduced bleeding, and promoted skin tightening. This study sought to perform a comparative histologic evaluation of laser lipolysis with the pulsed 1064-nm Nd:YAG laser versus a continuous 980-nm diode laser. A pulsed 1064-nm Nd:YAG (Smart-Lipo; Deka, Italy) and a CW 980-nm diode laser (Pharaon, Osyris, France) were evaluated at different energy settings for lipolysis on the thighs of a fresh cadaver. The lasers were coupled to a 600-microm optical fiber inserted in a 1-mm diameter cannula. Biopsy specimens were taken on irradiated and non-irradiated areas. Hematoxylin-erythrosin-safran staining and immunostaining (anti-PS100 polyclonal antibody) were performed to identify fat tissue damage. In the absence of laser exposures (control specimens), cavities created by cannulation were seen; adipocytes were round in appearance and not deflated. At low energy settings, tumescent adipocytes were observed. At higher energy settings, cytoplasmic retraction, disruption of membranes, and heat-coagulated collagen fibers were noted; coagulated blood cells were also present. For the highest energy settings, carbonization of fat tissue involving fibers and membranes was clearly seen. For equivalent energy settings, 1064-nm and 980-nm wavelengths gave similar histologic results. Laser lipolysis is a relatively new technique that is still under development. Our histologic findings suggest several positive benefits of the laser, including skin retraction and a reduction in intraoperative bleeding. The interaction of the laser with the tissue is similar at 980 nm and 1064 nm with the same energy settings. Because higher volumes of fat are removed with higher total energy, a high-power 980-nm diode laser could offer an interesting alternative to the 1064-nm Nd

  3. Exposure of Chlorpromazine to 266 nm Laser Beam Generates New Species with Antibacterial Properties: Contributions to Development of a New Process for Drug Discovery

    Science.gov (United States)

    Pascu, Mihail Lucian; Danko, Balazs; Martins, Ana; Jedlinszki, Nikoletta; Alexandru, Tatiana; Nastasa, Viorel; Boni, Mihai; Militaru, Andra; Andrei, Ionut Relu; Staicu, Angela; Hunyadi, Attila; Fanning, Seamus; Amaral, Leonard

    2013-01-01

    Introduction Phenothiazines when exposed to white light or to UV radiation undergo a variety of reactions that result in degradation of parental compound and formation of new species. This process is slow and may be sped up with exposure to high energy light such as that produced by a laser. Methods Varying concentrations of Chlorpromazine Hydrochloride (CPZ) (2–20 mg/mL in distilled water) were exposed to 266 nm laser beam (time intervals: 1–24 hrs). At distinct intervals the irradiation products were evaluated by spectrophotometry between 200–1500 nm, Thin Layer Chromatography, High Pressure Liquid Chromatography (HPLC) - Diode Array Detection, HPLC tandem mass spectrometry, and for activity against the CPZ sensitive test organism Staphylococcus aureus ATCC 25923. Results CPZ exposure to 266 nm laser beam of given energy levels yielded species, whose number increased with duration of exposure. Although the major species produced were Promazine (PZ), hydroxypromazine or PZ sulfoxide, and CPZ sulfoxide, over 200 compounds were generated with exposure of 20 mg/mL of CPZ for 24 hrs. Evaluation of the irradiation products indicated that the bioactivity against the test organism increased despite the total disappearance of CPZ, that is due, most probably, to one or more new species that remain yet unidentified. Conclusions Exposure of CPZ to a high energy (6.5 mJ) 266 nm laser beam yields rapidly a large number of new and stable species. For biological grade phenothiazines (in other words knowing the impurities in the samples: solvent and solute) this process may be reproducible because one can control within reasonably low experimental errors: the concentration of the parent compound, the laser beam wavelength and average energy, as well as the duration of the exposure time. Because the process is “clean” and rapid, it may offer advantages over the pyrogenically based methods for the production of derivatives. PMID:23405212

  4. Power scaling of laser diode pumped Pr3+:LiYF4 cw lasers: efficient laser operation at 522.6 nm, 545.9 nm, 607.2 nm, and 639.5 nm.

    Science.gov (United States)

    Gün, Teoman; Metz, Philip; Huber, Günter

    2011-03-15

    We report efficient cw laser operation of laser diode pumped Pr(3+)-doped LiYF4 crystals in the visible spectral region. Using two InGaN laser diodes emitting at λ(P)=443.9 nm with maximum output power of 1 W each and a 2.9-mm-long crystal with a doping concentration of 0.5%, output powers of 938 mW, 418 mW, 384 mW, and 773 mW were achieved for the laser wavelengths 639.5 nm, 607.2 nm, 545.9 nm, and 522.6 nm, respectively. The maximum absorbed pump powers were approximately 1.5 W, resulting in slope efficiencies of 63.6%, 32.0%, 52.1%, and 61.5%, as well as electro-optical efficiencies of 9.4%, 4.2%, 3.8%, and 7.7%, respectively. Within these experiments, laser diode-pumped laser action at 545.9 nm was demonstrated for what is believed to be the first time.

  5. Studies on nanosecond 532nm and 355nm and ultrafast 515nm and 532nm laser cutting super-hard materials

    Science.gov (United States)

    Zhang, Jie; Tao, Sha; Wang, Brian; Zhao, Jay

    2017-02-01

    In this paper, micro-processing of three kinds of super-hard materials of poly-crystal diamond (PCD)/tungsten-carbide (WC), CVD-diamond and cubic boron nitride (CNB) has been systematically studied using nanosecond laser (532nm and 355nm), and ultrafast laser (532nm and 515nm). Our purpose is to investigate a full laser micro-cutting solution to achieve a ready-to-use cutting tool insert (CTI). The results show a clean cut with little burns and recasting at edge. The cutting speed of 2-10mm/min depending on thickness was obtained. The laser ablation process was also studied by varying laser parameters (wavelength, pulse width, pulse energy, repetition rate) and tool path to improve cutting speed. Also, studies on material removal efficiency (MRE) of PCD/WC with 355nm-ns and 515nm-fs laser as a function of laser fluence show that 355nm-ns laser is able to achieve higher MRE for PCD and WC. Thus, ultrafast laser is not necessarily used for superhard material cutting. Instead, post-polishing with ultrafast laser can be used to clean cutting surface and improve smoothness.

  6. Tapered diode laser pumped 946 nm Nd:YAG laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2009-01-01

    We successfully implemented a 946 nm Nd:YAG laser based on a 808 nm tapered diode pump laser. The tapered diode is developed at the Ferdinand-Braun-Institute fur Hochstfrequenztechnik in Germany. Figure 2 shows the experimental setup and results of each pump source coupled into a 1.5 mm crystal...... laser, we show that tapered diode laser pumping potentially increase the power of 946 nm lasers by a factor of two and reduce the threshold by a factor of three....

  7. Sub-10-nm suspended nano-web formation by direct laser writing

    Science.gov (United States)

    Wang, Sihao; Yu, Ye; Liu, Hailong; Lim, Kevin T. P.; Madurai Srinivasan, Bharathi; Zhang, Yong Wei; Yang, Joel K. W.

    2018-06-01

    A diffraction-limited three-dimensional (3D) direct laser writing (DLW) system based on two-photon polymerization can routinely pattern structures at the 100 nm length scale. Several schemes have been developed to improve the patterning resolution of 3D DLW but often require customized resist formulations or multi-wavelength exposures. Here, we introduce a scheme to produce suspended nano-webs with feature sizes below 10 nm in IP-Dip resist using sub-threshold exposure conditions in a commercial DLW system. The narrowest suspended lines (nano-webs) measured 7 nm in width. Larger ∼20 nm nano-webs were patterned with ∼80% yield at increased laser powers. In addition, closely spaced nano-gaps with a center-to-center distance of 33 nm were produced by patterning vertically displaced suspended lines followed by metal deposition and liftoff. We provide hypotheses and present preliminary results for a mechanism involving the initiation of a percolative path and a strain-induced narrowing in the nano-web formation. Our approach allows selective features to be patterned with dimensions comparable to the sub-10 nm patterning capability of electron-beam lithography (EBL).

  8. High power diode lasers emitting from 639 nm to 690 nm

    Science.gov (United States)

    Bao, L.; Grimshaw, M.; DeVito, M.; Kanskar, M.; Dong, W.; Guan, X.; Zhang, S.; Patterson, J.; Dickerson, P.; Kennedy, K.; Li, S.; Haden, J.; Martinsen, R.

    2014-03-01

    There is increasing market demand for high power reliable red lasers for display and cinema applications. Due to the fundamental material system limit at this wavelength range, red diode lasers have lower efficiency and are more temperature sensitive, compared to 790-980 nm diode lasers. In terms of reliability, red lasers are also more sensitive to catastrophic optical mirror damage (COMD) due to the higher photon energy. Thus developing higher power-reliable red lasers is very challenging. This paper will present nLIGHT's released red products from 639 nm to 690nm, with established high performance and long-term reliability. These single emitter diode lasers can work as stand-alone singleemitter units or efficiently integrate into our compact, passively-cooled Pearl™ fiber-coupled module architectures for higher output power and improved reliability. In order to further improve power and reliability, new chip optimizations have been focused on improving epitaxial design/growth, chip configuration/processing and optical facet passivation. Initial optimization has demonstrated promising results for 639 nm diode lasers to be reliably rated at 1.5 W and 690nm diode lasers to be reliably rated at 4.0 W. Accelerated life-test has started and further design optimization are underway.

  9. Comparison of the ablation ability of nucleus pulposus after 1,064 nm Nd:YAG laser and 980 nm diode laser radiation.

    Science.gov (United States)

    Yin, Jian; Han, Zhengfeng; Guo, Baofeng; Guo, Han; Zhang, Tongtong; Zeng, Yanjun; Ren, Longxi

    2015-07-01

    To compare the ablation ability of nucleus pulposus after 1,064 nm Nd:YAG laser and 980 nm diode laser radiation. Goat spine specimen (GSS) was radiated using Nd:YAG laser and 980 nm diode laser and then divided into five groups based on the final energy--200, 400, 600, 800 and 1,000 J groups. The ablation quality of nucleus pulposus after radiation was recorded. The ablation quality of GSS was greater at higher radiation energies in both lasers. When compared at the same energy level, the ablation quality of GSS was greater in 980 nm diode laser than in 1,064 nm Nd:YAG laser. Statistical significance was observed in 200 and 400 J groups (P diode laser showed better ablation ability than 1,064 nm Nd:YAG laser.

  10. Comparison of 193 nm and 308 nm laser liquid printing by shadowgraphy imaging

    Energy Technology Data Exchange (ETDEWEB)

    Palla-Papavlu, A., E-mail: apalla@nipne.ro [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania); Shaw-Stewart, J. [EMPA, Swiss Federal Laboratories for Materials Testing and Research, Laboratory for Functional Polymers, Überlandstrasse 129, 8600 Dübendorf (Switzerland); Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Mattle, T. [Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Dinca, V. [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania); Lippert, T.; Wokaun, A. [Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Dinescu, M. [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania)

    2013-08-01

    Over the last years laser-induced forward transfer has emerged as a versatile and powerful tool for engineering surfaces with active compounds. Soft, easily damageable materials can be transferred using a triazene polymer as a sacrificial layer which acts as a pressure generator and at the same time protects the material from direct laser irradiation. To understand and optimize the transfer process of biomolecules in liquid solution by using an intermediate triazene polymer photosensitive layer, shadowgraphy imaging is carried out. Two laser systems i.e. an ArF laser operating at 193 nm and a XeCl laser operating at 308 nm are applied for the transfer. Solutions with 50% v/v glycerol concentration are prepared and the influence of the triazene polymer sacrificial layer thickness (60 nm) on the deposits is studied. The shadowgraphy images reveal a pronounced difference between laser-induced forward transfer using 193 nm or 308 nm, i.e. very different shapes of the ejected liquid.

  11. The Versatility of 980 nm Diode Laser in Dentistry: A Case Series.

    Science.gov (United States)

    Derikvand, Nahid; Chinipardaz, Zahra; Ghasemi, Sara; Chiniforush, Nasim

    2016-01-01

    Introduction: Laser surgery has been considered a popular alternative over conventional modalities in dentistry during the last few years. Among different types of lasers, diode lasers have gained special attention in oral soft tissue surgery. Case Reports: Five patients were referred to a private office. After careful evaluation of medical history and oral examination, oral diagnosis and treatment plan of each patient was established as follows: (1) A 21-year-old female with ankyloglossia (tongue-tie); (2) A 65-year-old female with a poor denture fit needing vestibuloplasty and frenectomy; (3) A 10-year-old male patient with pigmented gingiva in mandible and maxilla; (4) A 14-year-old female needing exposure of maxillary right canine for bracket bonding; and (5) A 25-year-old female patient who has a gingival maxillary frenum with a nodule. The treatment plan for all the patients was laser surgery with diode laser at 980 nm, in continuous mode. Results: All the patients experienced normal healing process with no postoperative complications. Favorable outcomes of laser surgery were observed on follow-up sessions. Conclusion: Considering the versatility of the 980 nm diode laser in oral soft tissue surgeries and the advantages of laser surgery, this study suggests the use of 980 nm diode laser in this regard.

  12. Novel 755-nm diode laser vs. conventional 755-nm scanned alexandrite laser: Side-by-side comparison pilot study for thorax and axillary hair removal.

    Science.gov (United States)

    Paasch, Uwe; Wagner, Justinus A; Paasch, Hartmut W

    2015-01-01

    Alexandrite (755 nm) and diode lasers (800-810 nm) are commonly used for hair removal. The alexandrite laser technology is somewhat cumbersome whereas new diode lasers are more robust. Recently, alexandrite-like 755 nm wavelength diodes became available. To compare the efficacy, tolerability, and subject satisfaction of a 755 nm diode laser operated in conventional (HR) and non-conventional in-motion (SHR) modes with a conventional scanned alexandrite 755 nm laser for chest and axillary hair removal. A prospective, single-center, proof of principle study was designed to evaluate the safety, efficacy and handling of a 755 nm diode laser system in comparison to a standard alexandrite 755 nm scanning hair removal laser. The new 755 nm diode is suitable to be used in SHR and HR mode and has been tested for its safety, efficacy and handling in a volunteer with success. Overall, both systems showed a high efficacy in hair reduction (88.8% 755 nm diode laser vs. 77.7% 755 nm alexandrite laser). Also, during the study period, no severe adverse effects were reported. The new 755 nm diode laser is as effective and safe as the traditional 755 nm alexandrite laser. Additionally, treatment with the 755 nm diode laser with HR and SHR modes was found to be less painful.

  13. 308nm Excimer Laser in Dermatology

    Science.gov (United States)

    Mehraban, Shadi

    2014-01-01

    308nm xenon-chloride excimer laser, a novel mode of phototherapy, is an ultraviolet B radiation system consisting of a noble gas and halide. The aim of this systematic review was to investigate the literature and summarize all the experiments, clinical trials and case reports on 308-nm excimer laser in dermatological disorders. 308-nm excimer laser has currently a verified efficacy in treating skin conditions such as vitiligo, psoriasis, atopic dermatitis, alopecia areata, allergic rhinitis, folliculitis, granuloma annulare, lichen planus, mycosis fungoides, palmoplantar pustulosis, pityriasis alba, CD30+ lympho proliferative disorder, leukoderma, prurigo nodularis, localized scleroderma and genital lichen sclerosus. Although the 308-nm excimer laser appears to act as a promising treatment modality in dermatology, further large-scale studies should be undertaken in order to fully affirm its safety profile considering the potential risk, however minimal, of malignancy, it may impose. PMID:25606333

  14. Diode laser (980nm) cartilage reshaping

    Science.gov (United States)

    El Kharbotly, A.; El Tayeb, T.; Mostafa, Y.; Hesham, I.

    2011-03-01

    Loss of facial or ear cartilage due to trauma or surgery is a major challenge to the otolaryngologists and plastic surgeons as the complicated geometric contours are difficult to be animated. Diode laser (980 nm) has been proven effective in reshaping and maintaining the new geometric shape achieved by laser. This study focused on determining the optimum laser parameters needed for cartilage reshaping with a controlled water cooling system. Harvested animal cartilages were angulated with different degrees and irradiated with different diode laser powers (980nm, 4x8mm spot size). The cartilage specimens were maintained in a deformation angle for two hours after irradiation then released for another two hours. They were serially measured and photographed. High-power Diode laser irradiation with water cooling is a cheep and effective method for reshaping the cartilage needed for reconstruction of difficult situations in otorhinolaryngologic surgery. Key words: cartilage,diode laser (980nm), reshaping.

  15. Compact corner-pumped Nd:YAG/YAG composite slab 1319 nm/1338 nm laser

    International Nuclear Information System (INIS)

    Liu, H; Gong, M; Wushouer, X; Gao, S

    2010-01-01

    A corner-pumped type is a new pumping type in the diode-pumped solid-state lasers, which has the advantages of high pump efficiency and favorable pump uniformity. A corner-pumped Nd:YAG/YAG composite slab continuous-wave 1319 nm/1338 nm dual-wavelength laser is first demonstrated in this paper. When the cavity length is 25 mm, the maximal output power is up to 7.62 W with a slope efficiency of 16.6% and an optical-to-optical conversion efficiency of 17%. The corresponding spectral line widths of 1319 nm laser and 1338 nm laser are 0.11 and 0.1 nm, respectively. The short-term instability of the output power is better than 1% when the pumping power is 39.5 W. The experimental results show that a corner-pumped type is a kind of feasible schedules in the design of diode-pumped solid-state 1.3 μm lasers with low or medium output powers

  16. PM Raman fiber laser at 1679 nm

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2012-01-01

    We demonstrate a PM Raman fiber laser emitting light at 1679 nm. The laser has an slope efficiency of 67 % and an output power of more than 275mWwith a 27 pm linewidth.......We demonstrate a PM Raman fiber laser emitting light at 1679 nm. The laser has an slope efficiency of 67 % and an output power of more than 275mWwith a 27 pm linewidth....

  17. Treatment of inflammatory facial acne vulgaris with combination 595-nm pulsed-dye laser with dynamic-cooling-device and 1,450-nm diode laser.

    Science.gov (United States)

    Glaich, Adrienne S; Friedman, Paul M; Jih, Ming H; Goldberg, Leonard H

    2006-03-01

    The 585-nm pulsed-dye laser and the 1,450-nm diode laser have been found effective for the treatment of mild-to-moderate inflammatory facial acne. This study was designed to evaluate the efficacy and safety of the combined treatment with the 595-nm pulsed-dye laser and the 1,450-nm diode laser for inflammatory facial acne. Fifteen patients with inflammatory facial acne were treated with a combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser. Patients' subjective response to treatment was evaluated regarding improvement in acne, acne scarring, oiliness, and redness of the skin. All patients had reductions in acne lesion counts. Mean lesion counts decreased 52% (P < 0.01), 63% (P < 0.01), and 84% (P < 0.01) after one, two, and three treatments, respectively. Patients described moderate-to-marked improvement in acne, acne scarring, and post-inflammatory erythema. Adverse effects were limited to mild, transient erythema. The combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser is safe and effective for the treatment of inflammatory facial acne, acne scarring, and post-inflammatory erythema. 2005 Wiley-Liss, Inc.

  18. Picosecond laser texturization of mc-silicon for photovoltaics: A comparison between 1064 nm, 532 nm and 355 nm radiation wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Binetti, Simona [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Le Donne, Alessia, E-mail: alessia.ledonne@mater.unimib.it [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Rolfi, Andrea [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Jäggi, Beat; Neuenschwander, Beat [Bern University of Applied Sciences, Engineering and Information Technology, Institute for Applied Laser, Photonics and Surface Technologies ALPS, Pestalozzistrasse 20, CH-3400 Burgdorf (Switzerland); Busto, Chiara [ENI Spa, Via Giacomo Fauser, 4, 28100 Novara (Italy); Frigeri, Cesare [CNR-IMEM Institute, Parco Area Delle Scienze 37/A, Fontanini, 43010 Parma (Italy); Scorticati, Davide; Longoni, Luca; Pellegrino, Sergio [Laserpoint Srl, Via Della Burrona 51, 20090 Vimodrone, Milano (Italy)

    2016-05-15

    Highlights: • Self-organized surface structures were produced by picosecond laser pulses on mc-Si. • Three laser wavelengths were used which effectively reduce Si reflectivity up to 8%. • The subsurface damage induced by the three lasers was studied in detail. • μ-Raman, PL and TEM proved that UV laser provides the lowest subsurface damage. • UV laser induced damage is located above the depletion region of the p–n junction. - Abstract: Self-organized surface structures were produced by picosecond laser pulses on multi-crystalline silicon for photovoltaic applications. Three different laser wavelengths were employed (i.e. 1064 nm, 532 nm and 355 nm) and the resulting morphologies were observed to effectively reduce the reflectivity of the samples after laser irradiation. Besides, a comparative study of the laser induced subsurface damage generated by the three different wavelengths was performed by confocal micro-Raman, photoluminescence and transmission electron microscopy. The results of both the structural and optical characterization showed that the mc-Si texturing performed with the laser at 355 nm provides surface reflectivity between 11% and 8% over the spectral range from 400 nm to 1 μm, while inducing the lowest subsurface damage, located above the depletion region of the p–n junction.

  19. Combination of Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, non-ablative 1450-nm diode laser, and ablative 10 600-nm carbon dioxide fractional laser for enlarged pores.

    Science.gov (United States)

    Cho, Sung Bin; Noh, Seongmin; Lee, Sang Ju; Kang, Jin Moon; Kim, Young Koo; Lee, Ju Hee

    2010-07-01

    Currently, there is no gold standard for the treatment of enlarged facial pores. In this report, we describe a patient with enlarged nasal pores which were treated with a combination of a non-ablative 1450-nm diode laser, a Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, and an ablative 10 600-nm carbon dioxide fractional laser system. Four months after the final treatment, the condition of the patient's pores had markedly improved, and the patient was satisfied with the results.

  20. Prospective study of the 532 nm laser (KTP) versus diode laser 980 nm in the resection of hyperplastic lesions of the oral cavity

    Science.gov (United States)

    Bargiela-Pérez, Patricia; González-Merchán, Jorge; Díaz-Sánchez, Rosa; Serrera-Figallo, Maria-Angeles; Volland, Gerd; Joergens, Martin; Gutiérrez-Pérez, Jose-Luis

    2018-01-01

    Background The aim of this study is to evaluate the resection of hyperplastic lesions on the buccal mucosa comparing the 532nm laser (KTP), versus diode 980nm laser, considering pain, scarring, inflammation and drug consumption that occurred postoperatively with each lasers. Material and Methods A prospective study of consecutive series of 20 patients in two groups that presents hyperplastic lesions on the buccal mucosa. The choice of the KTP laser or diode 980nm laser for the surgery was made randomly. The power used was 1.5W in both groups in a continuous wave mode with a 320 μm optical fiber. Parameters of pain, scarring, inflammation and consumption of drugs were recorded by a Numerical Rating Scale and evaluated postoperatively. These recordings were made the day of the surgery, 24 hours after, 14 and 28 days after. Results Pain and inflammation was light - moderate. The consumption of paracetamol was somewhat higher in the diode 980nm laser versus the KTP laser after 24 hours, although data was not statistically significant; significant differences were found after 28 days in regards to pain (p = 0.023) and inflammation (p = 0.023), but always in the absence parameter so we find no pain in both lasers. Scarring in the two types of laser showed no differences along the visits, with not detected scar retractable. Conclusions Although there is a slight histological difference regarding the KTP laser in the oral soft tissues for clinical use, both wavelengths are very suitable for excision of oral fibroma. Key words:Laser surgery, Laser therapy, oral surgery, soft tissue, 980 nm diode laser, 532 nm KTP laser. PMID:29274158

  1. Comparison of a novel high-power blue diode laser (λ=442 nm) with Ho:YAG (λ=2100 nm), Tm fiber (λ=1940 nm), and KTP (λ=532 nm) lasers for soft tissue ablation

    Science.gov (United States)

    Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and

  2. Ablative Fractional 10 600 nm Carbon Dioxide Laser Versus Non-ablative Fractional 1540 nm Erbium-Glass Laser in Egyptian Post-acne Scar patients.

    Science.gov (United States)

    Elsaie, Mohamed L; Ibrahim, Shady M; Saudi, Wael

    2018-01-01

    Introduction: Non-ablative fractional erbium-doped glass 1540 nm and fractional ablative 10600 nm carbon dioxide lasers are regarded as effective modalities for treating acne atrophic scars. In this study, we aimed to compare the effectiveness of fractional CO 2 laser and fractional nonablative 1540 nm erbium doped glass laser in treating post acne atrophic scars in Egyptian patients. Methods: Fifty-eight patients complaining of moderate and severe acne atrophic scars were randomly divided into 2 groups of 29 patients each. Both groups were subjected to 4 treatment sessions with 3 weeks interval and were followed up for 3 months. In group A, enrolled patient sreceived C2 laser, while in group B, patients were treated with 1540 nm erbium glass fractional laser. Results: Clinical assessment revealed that the mean grades of progress and improvement were higher with fractional 10600 nm CO2 laser but with non-significant difference between both treatments ( P = 0.1). The overall patients' satisfaction with both lasers were not significantly different ( P = 0.44). Conclusion: Both fractional ablative CO2 and fractional non-ablative erbium glass lasers are good modalities for treating acne scars with a high efficacy and safety profile and good patient satisfaction. The fractional ablative laser showed higher efficacy while non-ablative laser offered less pain and shorter downtime.

  3. Porcine skin damage thresholds for pulsed nanosecond-scale laser exposure at 1064-nm

    Science.gov (United States)

    DeLisi, Michael P.; Peterson, Amanda M.; Noojin, Gary D.; Shingledecker, Aurora D.; Tijerina, Amanda J.; Boretsky, Adam R.; Schmidt, Morgan S.; Kumru, Semih S.; Thomas, Robert J.

    2018-02-01

    Pulsed high-energy lasers operating in the near-infrared (NIR) band are increasingly being used in medical, industrial, and military applications, but there are little available experimental data to characterize their hazardous effects on skin tissue. The current American National Standard for the Safe Use of Lasers (ANSI Z136.1-2014) defines the maximum permissible exposure (MPE) on the skin as either a single-pulse or total exposure time limit. This study determined the minimum visible lesion (MVL) damage thresholds in Yucatan miniature pig skin for the single-pulse case and several multiple-pulse cases over a wide range of pulse repetition frequencies (PRFs) (10, 125, 2,000, and 10,000 Hz) utilizing nanosecond-scale pulses (10 or 60 ns). The thresholds are expressed in terms of the median effective dose (ED50) based on varying individual pulse energy with other laser parameters held constant. The results confirm a decrease in MVL threshold as PRF increases for exposures with a constant number of pulses, while also noting a PRF-dependent change in the threshold as a function of the number of pulses. Furthermore, this study highlights a change in damage mechanism to the skin from melanin-mediated photomechanical events at high irradiance levels and few numbers of pulses to bulk tissue photothermal additivity at lower irradiance levels and greater numbers of pulses. The observed trends exceeded the existing exposure limits by an average factor of 9.1 in the photothermally-damaged cases and 3.6 in the photomechanicallydamaged cases.

  4. Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser

    Directory of Open Access Journals (Sweden)

    Sanjiv K Gupta

    2012-01-01

    Conclusions: Transcanalicular Laser DCR can be safely performed using a low power 810 nm diode laser. The surgery is elegant, minimally invasive, allows fast rehabilitation, and has an excellent success rate.

  5. Comparison of the effects of 665 nm low level diode Laser Hat versus and a combination of 665 nm and 808nm low level diode Laser Scanner of hair growth in androgenic alopecia.

    Science.gov (United States)

    Barikbin, Behrooz; Khodamrdi, Zeinab; Kholoosi, Leila; Akhgri, Mohammad Reza; Haj Abbasi, Majid; Hajabbasi, Mojgan; Razzaghi, Zahra; Akbarpour, Samaneh

    2017-05-17

    This study aimed to evaluate the effectiveness of a combined set of low level diode laser scanner (665 nm and 808nm) on hair growth, and assessment of safety and effectiveness of a new laser scanner on hair growth treatment procedure in androgenic alopecia. 90 patients (18 to 70 years) with androgenic alopecia were randomized into three groups. The first group (n=30) received 655 nm red light using laser hat, the second group (n=30) received 655 nm red laser plus 808 nm infrared laser using a laser scanner of hair growth device (with the patent number: 77733) and the third group (n=30) received no laser as the control group. Patients in laser scanner group had better results and showed a higher increase in terminal hair density compared with laser hat group (mean of 9.61 versus 9.16 per cm 2 ). We found significant decrease in terminal hair density from baseline in control group (mean -1.8 per cm 2 , plaser scanner of the hair growth group compared with laser hat and the control group. The study showed that treatment with new laser devise had a promising result without any observable adverse effects.

  6. Diverse effects of a 445 nm diode laser on isometric contraction of the rat aorta

    Science.gov (United States)

    Park, Sang Woong; Shin, Kyung Chul; Park, Hyun Ji; Lee, In Wha; Kim, Hyung-Sik; Chung, Soon-Cheol; Kim, Ji-Sun; Jun, Jae-Hoon; Kim, Bokyung; Bae, Young Min

    2015-01-01

    The usefulness of visible lasers in treating vascular diseases is controversial. It is probable that multiple effects of visible lasers on blood vessels and their unclear mechanisms have hampered the usefulness of this therapy. Therefore, elucidating the precise actions and mechanisms of the effects of lasers on blood vessels would provide insight into potential biomedical applications. Here, using organ chamber isometric contraction measurements, western blotting, patch-clamp, and en face immunohistochemistry, we showed that a 445 nm diode laser contracted rat aortic rings, both by activating endothelial nitric oxide synthase and by increasing oxidative stress. In addition to the effects on the endothelium, the laser also directly relaxed and contracted vascular smooth muscle by inhibiting L-type Ca2+ channels and by activating protein tyrosine kinases, respectively. Thus, we conclude that exposure to 445 nm laser might contract and dilate blood vessels in the endothelium and smooth muscle via distinct mechanisms. PMID:26417517

  7. Efficient laser-diode end-pumped Nd:GGG lasers at 1054 and 1067 nm.

    Science.gov (United States)

    Xu, Bin; Xu, Huiying; Cai, Zhiping; Camy, P; Doualan, J L; Moncorgé, R

    2014-10-10

    Efficient and compact laser-diode end-pumped Nd:GGG simultaneous multiwavelength continuous-wave lasers at ∼1059, ∼1060 and ∼1062  nm were first demonstrated in a free-running 30 mm plano-concave laser cavity. The maximum output power was up to 3.92 W with a slope efficiency of about 53.6% with respect to the absorbed pump power. By inserting a 0.1 mm optical glass plate acting as a Fabry-Pérot etalon, a single-wavelength laser at ∼1067  nm with a maximum output power of 1.95 W and a slope efficiency of 28.5% can be obtained. Multiwavelength lasers, including those at ∼1054 or ∼1067  nm, were also achievable by suitably tilting the glass etalon. These simultaneous multiwavelength lasers provide a potential source for terahertz wave generation.

  8. Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser

    DEFF Research Database (Denmark)

    He, Ming; Jensen, Brian B; Therkildsen, Kasper T

    2009-01-01

    We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we obta...... obtained more than 40 mW of 517 nm output power by single pass frequency doubling. In addition, fluorescence spectroscopy of metastable magnesium atoms could be used to stabilize the 517 nm laser to an absolute frequency within 1 MHz.......We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we...

  9. Continuous-wave ceramic Nd:YAG laser at 1123 nm

    International Nuclear Information System (INIS)

    Zhang, S S; Wang, Q P; Zhang, X Y; Cong, Z H; Fan, S Z; Liu, Z J; Sun, W J

    2009-01-01

    Ceramic Nd:YAG (cNd:YAG) materials are employed to generate 1123-nm laser. A fiber-coupled continuous-wave (CW) 808-nm diode laser is used as the pumping source. With an incident diode power of 26.1 W, a CW output power of up to 10.8 W is obtained with a 10-mm-long ceramic Nd:YAG rod (1.0 at.%-Nd-doped). The conversion efficiency from diode power to 1123-nm laser power is 41.4%. The laser performance of another 10-mm-long cNd:YAG rod with a Nd-doping concentration of 0.6 at.% is studied as a comparison

  10. Passively mode-locked Nd:YVO4 laser operating at 1073 nm and 1085 nm

    Science.gov (United States)

    Waritanant, Tanant; Major, Arkady

    2018-02-01

    A passively mode-locked Nd:YVO4 laser operating at 1073 nm and 1085 nm was demonstrated with an intracavity birefringent filter as the wavelength selecting element. The average output powers achieved were 2.17 W and 2.18 W with optical-to-optical efficiency of 19.6% and 19.7%, respectively. The slope efficiencies were more than 31% at both output wavelengths. The pulse durations at the highest average output power were 10.3 ps and 8.4 ps, respectively. We believe that this is the first report of mode locking of a Nd:YVO4 laser operating at 1073 nm or 1085 nm lines.

  11. Treatment of tattoos with a 755-nm Q-switched alexandrite laser and novel 1064 nm and 532 nm Nd:YAG laser handpieces pumped by the alexandrite treatment beam.

    Science.gov (United States)

    Bernstein, Eric F; Bhawalkar, Jay; Clifford, Joan; Hsia, James

    2010-11-01

    Multi-colored and even black tattoos often require more than one wavelength to remove the target pigment. The authors report here a novel alexandrite laser with two Nd:YAG laser handpieces pumped by the alexandrite treatment beam enabling the delivery of three wavelengths from a single device. To describe and evaluate the effectiveness of a novel Q-switched laser-pumped laser for treating tattoos. Twenty tattoos in 14 subjects were treated at four-week intervals using a combination of available wavelengths (532, 755 and 1064 nm) as determined by the treating physician. Digital cross-polarized photographs were taken before treatment and two months following the fourth and final treatment. Photographs were evaluated by three physician observers blinded as to the treatment condition and rated for clearance by the following scale: 1 = > 95 percent, 2 = 76-95 percent, 3 = 51-75 percent, 4 = 26-50 percent and 5 = 0-25 percent clearance. The average clearance score was 3.1, in the 51-75 percent range, two months following four treatments. No scarring, hyper- or hypopigmentation was noted on post-treatment photographs or by the treating physician. The alexandrite and alexandrite-pumped 532 nm and 1064 nm Q-switched lasers are effective for removing decorative tattoos, and represents the first commercial laser with laser-pumped, laser handpieces.

  12. Research development of thermal aberration in 193nm lithography exposure system

    Science.gov (United States)

    Wang, Yueqiang; Liu, Yong

    2014-08-01

    Lithographic exposure is the key process in the manufacture of the integrated circuit, and the performance of exposure system decides the level of microelectronic manufacture technology. Nowadays, the 193nm ArF immersion exposure tool is widely used by the IC manufacturer. With the uniformity of critical dimension (CDU) and overlay become tighter and the requirement for throughput become higher, the thermal aberration caused by lens material and structure absorbing the laser energy cannot be neglected. In this paper, we introduce the efforts and methods that researcher on thermal aberration and its control. Further, these methods were compared to show their own pros and cons. Finally we investigated the challenges of thermal aberration control for state of the art technologies.

  13. [Comparative investigation of underwater-LIBS using 532 and 1 064 nm lasers].

    Science.gov (United States)

    Song, Jiao-Jian; Tian, Ye; Lu, Yuan; Li, Ying; Zheng, Rong-Er

    2014-11-01

    With the hope of applying laser induced breakdown spectroscopy (LIBS) to the ocean applications, the laser energy at 532 and 1 064 nm wavelength with 3 and 40 mj respectively was used, which was near their breakdown threshold. Extensive experimental investigations of LIBS from CaCl2 water solution were carried out in this paper using different laser wavelengths of 532 and 1 064 nm. The obtained results show that compared with the 532 nm laser, the 1 064 nm laser can induce the plasma in water with higher emission intensity and longer lifetime, while the reproducibility of LIBS signal under 1 064 nm laser is poorer. On the other hand, due to the different attenuation ratios of 532 and 1 064 nm laser energies in water, the LIBS signal of 1 064 nm laser decreases a lot within the transmission distance range 2-5 cm, while LIBS signal of 532 nm remains the same, because that the wavelength of 532 nm lies in the "transmission window" of the water solution. This study will provide valuable design considerations for the development of LIBS-sea system in near future.

  14. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cahoon, Erica M.; Almirall, Jose R.

    2010-05-01

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and the mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.

  15. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Cahoon, Erica M.; Almirall, Jose R.

    2010-01-01

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and the mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.

  16. Efficient continuous-wave 1112 nm Nd:YAG laser operation under direct diode pumping at 885 nm

    International Nuclear Information System (INIS)

    Gao, J; Dai, X J; Zhang, L; Wu, X D

    2013-01-01

    We report compact diode-end-pumped continuous-wave laser operation at 1112 nm under 885 nm diode-direct pumping for the first time. On the basis of the R 2 →Y 6 transition in a conventional Nd:YAG (yttrium aluminum garnet) single crystal, the maximum output power of 12.5 W is achieved, with an optical to optical efficiency of 46.6% and a slope efficiency of 52.9%. To the best of our knowledge, this represents the highest output at 1112 nm generated by a diode-end-pumped Nd:YAG laser. Furthermore, it is the highest optical to optical efficiency ever reported for 1112 nm Nd:YAG lasers. The short term power stability is ∼0.32% at 12.0 W output. (letter)

  17. Rejuvenation of the male scalp using 1,927 nm non-ablative fractional thulium fiber laser.

    Science.gov (United States)

    Boen, Monica; Wilson, Monique J Vanaman; Goldman, Mitchel P; Wu, Douglas C

    2017-07-01

    The male scalp undergoes extensive photodamage due to a high prevalence of androgenic alopecia and exposure to ultraviolet radiation. This photodamage presents as solar lentigines, fine rhytides, and keratosis, and can prematurely age a patient. In this study, we demonstrate the safety and efficacy of the fractionated 1,927 nm thulium fiber laser using high density and high energy settings to achieve rejuvenation of the male scalp after a single treatment session. Four male patients with Fitzpatrick skin types II-III and extensive photodamage on the scalp underwent one treatment with the fractional non-ablative 1,927 nm thulium fiber laser. The patients had a 60-90% improvement in dyspigmentation, lentigines, and keratosis. No adverse events were observed and the patients tolerated the procedure well. This case series is the first report in the literature demonstrating the successful rejuvenation of the scalp using the 1,927 nm thulium fiber laser. Lasers Surg. Med. 49:475-479, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. Efficiency of soft tissue incision with a novel 445-nm semiconductor laser.

    Science.gov (United States)

    Braun, Andreas; Kettner, Moritz; Berthold, Michael; Wenzler, Johannes-Simon; Heymann, Paul Günther Baptist; Frankenberger, Roland

    2018-01-01

    Using a 445-nm semiconductor laser for tissue incision, an effective cut is expected due to the special absorption properties of blue laser light in soft tissues. The aim of the present study was the histological evaluation of tissue samples after incision with a 445-nm diode laser. Forty soft tissue specimens were obtained from pork oral mucosa and mounted on a motorized linear translation stage. The handpiece of a high-frequency surgery device, a 970-nm semiconductor laser, and a 445-nm semiconductor laser were connected to the slide, allowing a constant linear movement (2 mm/s) and the same distance of the working tip to the soft tissue's surface. Four incisions were made each: (I) 970-nm laser with conditioned fiber tip, contact mode at 3-W cw; (II-III): 445-nm laser with non-conditioned fiber tip, contact mode at 2-W cw, and non-contact mode (1 mm) at 2 W; and (IV): high-frequency surgery device with straight working tip, 90° angulation, contact mode at 50 W. Histological analysis was performed after H&E staining of the embedded specimens at 35-fold magnification. The comparison of the incision depths showed a significant difference depending on the laser wavelength and the selected laser parameters. The highest incision depth was achieved with the 445-nm laser contact mode (median depth 0.61 mm, min 0.26, max 1.17, interquartile range 0.58) (p laser, a higher cutting efficiency can be expected when compared with a 970-nm diode laser and high-frequency surgery. Even the 445-nm laser application in non-contact mode shows clinically acceptable incision depths without signs of extensive soft tissue denaturation.

  19. Diffraction-limited 577 nm true-yellow laser by frequency doubling of a tapered diode laser

    Science.gov (United States)

    Christensen, Mathias; Vilera, Mariafernanda; Noordegraaf, Danny; Hansen, Anders K.; Buß, Thomas; Jensen, Ole B.; Skovgaard, Peter M. W.

    2018-02-01

    A wide range of laser medical treatments are based on coagulation of blood by absorption of the laser radiation. It has, therefore, always been a goal of these treatments to maximize the ratio of absorption in the blood to that in the surrounding tissue. For this purpose lasers at 577 nm are ideal since this wavelength is at the peak of the absorption in oxygenated hemoglobin. Furthermore, 577 nm has a lower absorption in melanin when compared to green wavelengths (515 - 532 nm), giving it an advantage when treating at greater penetration depth. Here we present a laser system based on frequency doubling of an 1154 nm Distributed Bragg Reflector (DBR) tapered diode laser, emitting 1.1 W of single frequency and diffraction limited yellow light at 577 nm, corresponding to a conversion efficiency of 30.5%. The frequency doubling is performed in a single pass configuration using a cascade of two bulk non-linear crystals. The system is power stabilized over 10 hours with a standard deviation of 0.13% and the relative intensity noise is measured to be 0.064 % rms.

  20. Spectral narrowing of a 980 nm tapered diode laser bar

    Science.gov (United States)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Lucas Leclin, Ga"lle; Petersen, Paul Michael; Thestrup, Birgitte

    2011-03-01

    High power diode laser bars are interesting in many applications such as solid state laser pumping, material processing, laser trapping, laser cooling and second harmonic generation. Often, the free running laser bars emit a broad spectrum of the order of several nanometres which limit their scope in wavelength specific applications and hence, it is vital to stabilize the emission spectrum of these devices. In our experiment, we describe the wavelength narrowing of a 12 element 980 nm tapered diode laser bar using a simple Littman configuration. The tapered laser bar which suffered from a big smile has been "smile corrected" using individual phase masks for each emitter. The external cavity consists of the laser bar, both fast and slow axis micro collimators, smile correcting phase mask, 6.5x beam expanding lens combination, a 1200 lines/mm reflecting grating with 85% efficiency in the first order, a slow axis focusing cylindrical lens of 40 mm focal length and an output coupler which is 10% reflective. In the free running mode, the laser emission spectrum was 5.5 nm wide at an operating current of 30A. The output power was measured to be in excess of 12W. Under the external cavity operation, the wavelength spread of the laser could be limited to 0.04 nm with an output power in excess of 8 W at an operating current of 30A. The spectrum was found to be tuneable in a range of 16 nm.

  1. Widely Tunable High-Power Tapered Diode Laser at 1060 nm

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Sumpf, Bernd; Erbert, Götz

    2011-01-01

    We report a large tuning range from 1018 to 1093 nm from a InGaAs single quantum-well 1060-nm external cavity tapered diode laser. More than 2.5-W output power has been achieved. The tuning range is to our knowledge the widest obtained from a high-power InGaAs single quantum-well tapered laser...... operating around 1060 nm. The light emitted by the laser has a nearly diffraction limited beam quality and a narrow linewidth of less than 6 pm everywhere in the tuning range....

  2. Laser Application in Dentistry: Irradiation Effects of Nd:YAG 1064 nm and Diode 810 nm and 980 nm in Infected Root Canals—A Literature Overview

    Science.gov (United States)

    Kuypers, Thorsten; Gutknecht, Norbert

    2016-01-01

    Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment. PMID:27462611

  3. Laser Application in Dentistry: Irradiation Effects of Nd:YAG 1064 nm and Diode 810 nm and 980 nm in Infected Root Canals-A Literature Overview.

    Science.gov (United States)

    Saydjari, Yves; Kuypers, Thorsten; Gutknecht, Norbert

    2016-01-01

    Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment.

  4. Monolithic PM Raman fiber laser at 1679 nm for Raman amplification at 1810 nm

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2013-01-01

    Stimulated Raman scattering (SRS) has been subject to much attention within the field of fiber lasers and amplifiers as it provides an extended wavelength coverage in comparison to rare-earth based devices. Motivated by the projected capacity crunch [1], different approaches are being explored...... demonstrate a monolithic RM Raman fiber laser (RFL), which acts as a pump for a Raman amplifier (RA) at 1810 nm. The lasing wavelength of a RFL, thus also for a RA, can in principle be designed arbitrarily within the entire wavelength range from the Erbium band up to the Thulium/Holmium band...... of OFS PM Raman fiber, with an estimated propagation loss of 0.42/0.46/1.3 dB/km at 1564/1679/1810 nm. The Raman gain coefficient was measured to be gR=2.66/2.35 W-1km-1 at 1679/1810 nm. The laser curve of the RFL is depicted in Fig. 1b, with a slope efficiency of 67 %. The high slope efficiency...

  5. Optical breakdown threshold investigation of 1064 nm laser induced air plasmas

    International Nuclear Information System (INIS)

    Thiyagarajan, Magesh; Thompson, Shane

    2012-01-01

    We present the theoretical and experimental measurements and analysis of the optical breakdown threshold for dry air by 1064 nm infrared laser radiation and the significance of the multiphoton and collisional cascade ionization process on the breakdown threshold measurements over pressures range from 10 to 2000 Torr. Theoretical estimates of the breakdown threshold laser intensities and electric fields are obtained using two distinct theories namely multiphoton and collisional cascade ionization theories. The theoretical estimates are validated by experimental measurements and analysis of laser induced breakdown processes in dry air at a wavelength of 1064 nm by focusing 450 mJ max, 6 ns, 75 MW max high-power 1064 nm IR laser radiation onto a 20 μm radius spot size that produces laser intensities up to 3 - 6 TW/cm 2 , sufficient for air ionization over the pressures of interest ranging from 10 to 2000 Torr. Analysis of the measured breakdown threshold laser intensities and electric fields are carried out in relation with classical and quantum theoretical ionization processes, operating pressures. Comparative analysis of the laser air breakdown results at 1064 nm with corresponding results of a shorter laser wavelength (193 nm) [M. Thiyagarajan and J. E. Scharer, IEEE Trans. Plasma Sci. 36, 2512 (2008)] and a longer microwave wavelength (10 8 nm) [A. D. MacDonald, Microwave Breakdown in Gases (Wiley, New York, 1966)]. A universal scaling analysis of the breakdown threshold measurements provided a direct comparison of breakdown threshold values over a wide range of frequencies ranging from microwave to ultraviolet frequencies. Comparison of 1064 nm laser induced effective field intensities for air breakdown measurements with data calculated based on the collisional cascade and multiphoton breakdown theories is used successfully to determine the scaled collisional microwave portion. The measured breakdown threshold of 1064 nm laser intensities are then scaled to

  6. An Alternative Method of Evaluating 1540NM Exposure Laser Damage using an Optical Tissue Phantom

    National Research Council Canada - National Science Library

    Jindra, Nichole M; Figueroa, Manuel A; Rockwell, Benjamin A; Chavey, Lucas J; Zohner, Justin J

    2006-01-01

    An optical phantom was designed to physically and optically resemble human tissue, in an effort to provide an alternative for detecting visual damage resulting from inadvertent exposure to infrared lasers...

  7. Diode-pumped continuous-wave eye-safe Nd:YAG laser at 1415 nm.

    Science.gov (United States)

    Lee, Hee Chul; Byeon, Sung Ug; Lukashev, Alexei

    2012-04-01

    We describe the output performance of the 1415 nm emission in Nd:YAG in a plane-concave cavity under traditional pumping into the 4F5/2 level (808 nm) and direct in-band pumping into the 4F3/2 level (885 nm). An end-pumped Nd:YAG laser yielded maximum cw output power of 6.3 W and 4.2 W at 885 nm and 808 nm laser diode (LD) pumping, respectively. To the best of our knowledge, this is the highest output power of a LD-pumped 1415 nm laser.

  8. Diode-pumped CW Nd:SGG laser at 1070 nm

    International Nuclear Information System (INIS)

    Liang, W; Sun, G C; Yu, X; Li, B Z; Jin, G Y

    2011-01-01

    We report for the first time (to our knowledge) a diode-pumped Nd:SGG laser emitting at 1070 nm. A power of 1.23 W at 1070 nm has been achieved in continuous-wave (CW) operation with a fiber-coupled laser diode emitting 18.2 W at 806 nm. Intracavity second-harmonic generation (SHG) in CW mode has also been demonstrated with a power of 328 mW at 535 nm by using a LiB 3 O 5 (LBO) nonlinear crystal. The green beam quality factor M 2 was less than 1.22. The green power stability was less 2.5% in 4 hour

  9. High-power frequency-stabilized laser for laser cooling of metastable helium at 389 nm

    NARCIS (Netherlands)

    Koelemeij, J.C.J.; Hogervorst, W.; Vassen, W.

    2005-01-01

    A high-power, frequency-stabilized laser for cooling of metastable helium atoms using the 2 S13 →3 P23 transition at 389 nm has been developed. The 389 nm light is generated by frequency doubling of a titanium:sapphire laser in an external enhancement cavity containing a lithium-triborate nonlinear

  10. Laser Shock Processing of 6061-T6 Al alloy with 1064 nm and 532 nm wavelengths

    International Nuclear Information System (INIS)

    Gomez-Rosas, G.; Rubio-Gonzalez, C.; Ocana, J.L.; Molpeceres, C.; Porro, J.A.; Morales, M.; Casillas, F.J.

    2010-01-01

    Laser Shock Processing (LSP) has been proposed as a competitive alternative technology to classical treatments for improving fatigue and wear resistance of metals. We present a configuration and results in the LSP concept for metal surface treatments in underwater laser irradiation at 532 nm and 1064 nm. The purpose of the work is to compare the effect of both wavelengths on the same material. A convergent lens is used to deliver 1.2 J/pulse (1064 nm) and 0.9 J/pulse (532 nm) in a 8 ns laser FWHM pulse produced by 10 Hz Q-switched Nd:YAG laser with spots of a 1.5 mm in diameter moving forward along the work piece. A LSP configuration with experimental results using a pulse density of 2500 pulses/cm 2 and 5000 pulses/cm 2 in 6061-T6 aluminum samples are presented. High level compressive residual stresses are produced using both wavelengths. It has been shown that surface residual stress level is comparable to that achieved by conventional shot peening, but with greater depths. This method can be applied to surface treatment of final metal products.

  11. Deposition and characterization of ITO films produced by laser ablation at 355 nm

    DEFF Research Database (Denmark)

    Holmelund, E.; Thestrup Nielsen, Birgitte; Schou, Jørgen

    2002-01-01

    Indium tin oxide (ITO) films have been deposited by pulsed laser deposition (PLD) at 355 nm. Even though the absorption of laser light at the wavelength 355 nm is much smaller than that of the standard excimer lasers for PLD at 248 nm and 193 nm, high-quality films can be produced. At high fluence...

  12. Red and orange laser operation of Pr:KYF4 pumped by a Nd:YAG/LBO laser at 469.1 nm and a InGaN laser diode at 444 nm.

    Science.gov (United States)

    Xu, B; Starecki, F; Pabœuf, D; Camy, P; Doualan, J L; Cai, Z P; Braud, A; Moncorgé, R; Goldner, Ph; Bretenaker, F

    2013-03-11

    We report the basic luminescence properties and the continuous-wave (CW) laser operation of a Pr(3+)-doped KYF(4) single crystal in the Red and Orange spectral regions by using a new pumping scheme. The pump source is an especially developed, compact, slightly tunable and intra-cavity frequency-doubled diode-pumped Nd:YAG laser delivering a CW output power up to about 1.4 W around 469.1 nm. At this pump wavelength, red and orange laser emissions are obtained at about 642.3 and 605.5 nm, with maximum output powers of 11.3 and 1 mW and associated slope efficiencies of 9.3% and 3.4%, with respect to absorbed pump powers, respectively. For comparison, the Pr:KYF(4) crystal is also pumped by a InGaN blue laser diode operating around 444 nm. In this case, the same red and orange lasers are obtained, but with maximum output powers of 7.8 and 2 mW and the associated slope efficiencies of 7 and 5.8%, respectively. Wavelength tuning for the two lasers is demonstrated by slightly tilting the crystal. Orange laser operation and laser wavelength tuning are reported for the first time.

  13. Single, composite, and ceramic Nd:YAG 946-nm lasers

    Science.gov (United States)

    Lan, Rui-Jun; Yang, Guang; Zheng-Ping, Wang

    2015-06-01

    Single, composite crystal and ceramic continuous wave (CW) 946-nm Nd:YAG lasers are demonstrated, respectively. The ceramic laser behaves better than the crystal laser. With 5-mm long ceramic, a CW output power of 1.46 W is generated with an optical conversion efficiency of 13.9%, while the slope efficiency is 17.9%. The optimal ceramic length for a 946-nm laser is also calculated. Project supported by the National Natural Science Foundation of China (Grant No. 61405171), the Natural Science Foundation of Shandong Province, China (Grant No. ZR2012FQ014), and the Science and Technology Program of the Shandong Higher Education Institutions of China (Grant No. J13LJ05).

  14. 5.5nm wavelength-tunable high-power MOPA diode laser system at 971 nm

    Science.gov (United States)

    Tawfieq, Mahmoud; Müller, André; Fricke, Jörg; Della Casa, Pietro; Ressel, Peter; Ginolas, Arnim; Feise, David; Sumpf, Bernd; Tränkle, Günther

    2018-02-01

    In this work, a widely tunable hybrid master oscillator power amplifier (MOPA) diode laser with 6.2 W of output power at 971.8 nm will be presented. The MO is a DBR laser, with a micro heater embedded on top of the DBR grating for wavelength tunability. The emitted light of the MO is collimated and coupled into a tapered amplifier using micro cylindrical lenses, all constructed on a compact 25 mm × 25 mm conduction cooled laser package. The MOPA system emits light with a measured spectral width smaller than 17 pm, limited by the spectrometer, and with a beam propagation factor of M2 1/e2 = 1.3 in the slow axis. The emission is thus nearly diffraction limited with 79% of the total power within the central lobe (4.9 W diffraction limited). The electrically controlled micro-heater provides up to 5.5 nm of wavelength tunability, up to a wavelength of 977.3 nm, while maintaining an output power variation of only +/- 0.16 % for the entire tuning range.

  15. Compact 2100 nm laser diode module for next-generation DIRCM

    Science.gov (United States)

    Dvinelis, Edgaras; Greibus, Mindaugas; TrinkÅ«nas, Augustinas; NaujokaitÄ--, Greta; Vizbaras, Augustinas; Vizbaras, Dominykas; Vizbaras, Kristijonas

    2017-10-01

    Compact high-power 2100 nm laser diode module for next-generation directional infrared countermeasure (DIRCM) systems is presented. Next-generation DIRCM systems require compact, light-weight and robust laser modules which could provide intense IR light emission capable of disrupting the tracking sensor of heat-seeking missile. Currently used solid-state and fiber laser solutions for mid-IR band are bulky and heavy making them difficult to implement in smaller form-factor DIRCM systems. Recent development of GaSb laser diode technology greatly improved optical output powers and efficiencies of laser diodes working in 1900 - 2450 nm band [1] while also maintaining very attractive size, weight, power consumption and cost characteristics. 2100 nm laser diode module presented in this work performance is based on high-efficiency broad emitting area GaSb laser diode technology. Each laser diode emitter is able to provide 1 W of CW output optical power with working point efficiency up to 20% at temperature of 20 °C. For output beam collimation custom designed fast-axis collimator and slow-axis collimator lenses were used. These lenses were actively aligned and attached using UV epoxy curing. Total 2 emitters stacked vertically were used in 2100 nm laser diode module. Final optical output power of the module goes up to 2 W at temperature of 20 °C. Total dimensions of the laser diode module are 35 x 25 x 16 mm (L x W x H) with a weight of 28 grams. Finally output beam is bore-sighted to mechanical axes of the module housing allowing for easy integration into next-generation DIRCM systems.

  16. Q-switched Nd:YAG/V:YAG microchip 1338 nm laser for laser-induced breakdown spectroscopy

    Science.gov (United States)

    Šulc, Jan; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav

    2017-12-01

    Q-switched microchip laser emitting radiation at wavelength 1338nm was tested as a radiation source for laser induced breakdown spectroscopy (LIBS). This laser used sandwich crystal which combined in one piece the cooling part (undoped YAG crystal 4mm long), the active laser part (Nd:YAG crystal 12mm long), and the saturable absorber (V:YAG crystal 0.7mm long). The diameter of this crystal was 5 mm. The microchip resonator consisted of dielectric mirrors directly deposited on the monolith crystal surfaces. The pump mirror (HT @ 808 nm, HR @ 1.3 ¹m) was placed on the undoped YAG part. The output coupler (R = 90% @ 1338 nm) was placed on the V:YAG part. The fibre-coupled 808nm pumping laser diode was operating in pulsed regime (rep. rate 250 Hz, pulse width 300 ¹s, pulse energy 6 mJ). Using this pumping, stable and high reproducible Q-switched pulses were generated at wavelength 1338 nm. Pulse length was 6.2 ns (FWHM) and the mean output power was 33mW. The single pulse energy and peak power was 0.13mJ and 21kW, respectively. Laser was operating in fundamental TEM00 mode. The laser radiation was focused on a tested sample using single plano-convex lens (focal length 75 mm). The focal spot radius was 40 ¹m. The corresponding peak-power density was 0.83GW/cm2. The laser induced break-down was successfully reached and corresponding laser-induced plasma spectra were recorded for set of metallic elements (Cu, Ag, Au, In, Zn, Al, Fe, Ni, Cr) and alloys (Sn-Pb solder, duralumin, stainless-steel, brass). To record the spectra, StellarNet BLACK-Comet concave grating CCD-based spectrometer was used without any special collimation optics. Thanks to used laser wavelength far from the detector sensitivity, no special filtering was needed to overcome the CCD dazzling. The constructed laser could significantly improve repletion-rate of up-to-date LIBS devices.

  17. Surgical performance of a 405-nm diode laser in treatment of soft tissue

    International Nuclear Information System (INIS)

    Kato, J; Akashi, G; Moriya, K; Hirai, Y; Hatayama, H; Inoue, A; Miyazaki, H

    2008-01-01

    The study was conducted to evaluate the surgical performance of a 405-nm diode laser ex vivo. The experiments were carried out using tuna tissue, which was irradiated with a 405-nm diode laser at output powers of 400 mW (694 W/cm 2 ) to 1 W (1735 W/cm 2 ) on a motorized stage moving at a rate of 1 mm/sec. As a control, a 920-nm diode laser was used with the same irradiation conditions. After irradiation, the thickness of ablation and coagulation was measured by stereoscopic microscopy and evaluated statistically. Ablation and coagulation zones were obtained with 405-nm laser irradiation, but not with irradiation at 920 nm. Ablation depth increased significantly with output power and a thick coagulation zone was observed with 405-nm irradiation. The 405-nm diode laser performed well for incising and coagulating soft tissue at a low power density

  18. Investigations of a Dual Seeded 1178 nm Raman Laser System

    Science.gov (United States)

    2016-01-14

    was obtained by Raman amplification of a distributed feedback diode laser in a variably strained polarization- maintaining fiber with a record-high...Calia, D.B., “50W CW visible laser source at 589 nm obtained via frequency doubling of three coherently combined narrow-band Raman fiber amplifiers...AFRL-RD-PS- TP-2016-0009 AFRL-RD-PS- TP-2016-0009 INVESTIGATIONS OF A DUAL SEEDED 1178 NM RAMAN LASER SYSTEM Leanne Henry, et al. 14 January

  19. Quasi-three level Nd:YLF fundamental and Raman laser operating under 872-nm and 880-nm direct diode pumping

    Science.gov (United States)

    Wetter, Niklaus U.; Bereczki, Allan; Paes, João. Pedro Fonseca

    2018-02-01

    Nd:YLiF4 is the gain material of choice whenever outstanding beam quality or a birefringent gain material is necessary such as in certain applications for terahertz radiation or dual-frequency mode-locking. However, for high power CW applications the material is hampered by a low thermal fracture threshold. This problem can be mitigated by special 2D pump set-ups or by keeping the quantum defect to a minimum. Direct pumping into the upper laser level of Nd:YLiF4 is usually performed at 880 nm. For quasi-three level laser emission at 908 nm, direct pumping at this wavelength provides a high quantum defect of 0.97, which allows for very high CW pump powers. Although the direct pumping transition to the upper laser state at 872 nm has a slightly smaller quantum defect of 0.96, its pump absorption cross section along the c-axis is 50% higher than at 880 nm, leading to a higher absorption efficiency. In this work we explore, for the first time to our knowledge, 908 nm lasing under 872 nm diode pumping and compare the results with 880 nm pumping for quasicw and cw operation. By inserting a KGW crystal in the cavity, Raman lines at 990 nm and 972 nm were obtained for the first time from a directly pumped 908 nm Nd:YLF fundamental laser for both quasi-cw and cw conditions.

  20. 980nm laser for difficult-to-treat basal cell carcinoma

    Science.gov (United States)

    Derjabo, A. D.; Cema, I.; Lihacova, I.; Derjabo, L.

    2013-06-01

    Begin basal cell carcinoma (BCC) is most common skin cancer over the world. There are around 20 modalities for BCC treatment. Laser surgery is uncommon option. We demonstrate our long term follow up results. Aim: To evaluate long term efficacy of a 980nm diode laser for the difficult-to-treat basal cell carcinoma. Materials and Methods: 167 patients with 173 basal cell carcinoma on the nose were treated with a 980 nm diode laser from May 1999 till May 2005 at Latvian Oncology center. All tumors were morphologically confirmed. 156 patients were followed for more than 5 years. Results: The lowest recurrence rate was observed in cases of superficial BCC, diameterConclusions: 980 nm diode laser is useful tool in dermatology with high long term efficacy, good acceptance by the patients and good cosmetics results.

  1. A comparative study with a 755 nm picosecond Alexandrite laser with a diffractive lens array and a 532 nm/1064 nm Nd:YAG with a holographic optic.

    Science.gov (United States)

    Tanghetti Md, Emil; Jennings, John

    2018-01-01

    This study was performed to better understand the cutaneous effects of using a fractional picosecond laser at 755 nm with a diffractive lens array and a picosecond Nd:YAG laser at 532 mn and 1064 nm with a holographic optic. We characterized the injuries created by these devices on skin clinically and histologically over 24 hours. With this information we modeled the effects of these devices on a cutaneous target. Eight patients, representing Fitzpatrick skin types I-VI, were treated on their backs with a picosecond Alexandrite laser with a diffractive lens array, as well as a picosecond Nd:YAG laser at 532 nm and 1064 nm with a holographic optic. Photographs were taken 15 minutes and 24 hours after treatments. Punch biopsies were obtained at 24 hours and examined histologically. Treatment with the picosecond Nd:YAG laser at both 532 nm and 1064 nm with the holographic optic revealed erythema and small scatted areas of petechial hemorrhage areas immediately and in many cases at 24 hours after treatment. The 755 nm picosecond Alexandrite laser with diffractive lens array produced erythema immediately after treatment, which largely dissipated 24 hours later. Histologies revealed intra-epidermal vacuoles with all three wavelengths. Fractional picosecond Nd:YAG laser at 532 nm and 1064 nm with the holographic optic showed focal areas of dermal and intra-epidermal hemorrhage with areas of vascular damage in some patients. This study demonstrates that both fractional picosecond devices produce vacuoles in the skin, which are most likely due to areas of laser induced optical breakdown (LIOB). In the patients (skin type II-IV) we observed scatter areas of hemorrhage in the skin, due to vascular damage with the 532 nm and 1064 nm, but not with 755 nm wavelengths. Lasers Surg. Med. 50:37-44, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Diode-pumped cw Nd:YAG three-level laser at 869 nm.

    Science.gov (United States)

    Lü, Yanfei; Xia, Jing; Cheng, Weibo; Chen, Jifeng; Ning, Guobin; Liang, Zuoliang

    2010-11-01

    We report for the first time (to our knowledge) a diode-pumped Nd:YAG laser emitting at 869 nm based on the (4)F(3/2)-(4)I(9/2) transition, generally used for a 946 nm emission. Power of 453 mW at 869 nm has been achieved in cw operation with a fiber-coupled laser diode emitting 35.4 W at 809 nm. Intracavity second-harmonic generation in the cw mode has also been demonstrated with power of 118 mW at 435 nm by using a BiB(3)O(6) nonlinear crystal. In our experiment, we used a LiNbO(3) crystal lens to complement the thermal lens of the laser rod, and we obtained good beam quality and high output power stability.

  3. Surface effect of KrF laser exposure on ECE of alpha particle tracks in polycarbonate polymer

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, P. [Physics Department, Amirkabir University, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of) and Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of)]. E-mail: parvin@aut.ac.ir; Jaleh, B. [Physics Department, Bu Ali Sina University, Hamadan (Iran, Islamic Republic of); Sheikh, N. [Gamma Irradiation Center, AEOI, Tehran (Iran, Islamic Republic of); Amiri, N. [Physics Department, Emam Hossien University, Tehran (Iran, Islamic Republic of)

    2005-11-15

    The optical penetration depth for polycarbonate (PC) at 308nm due to XeCl laser is about 450{mu}m while those of KrF (248nm) and ArF (193nm) lasers become noticeably shorter to 1{mu}m and 20nm, respectively, to show the strong superficial absorption at shorter UV wavelengths. On the other hand, KrF laser exposure on polycarbonate, at doses above 6J/cm{sup 2}, creates the surface crosslinking. In spite of several reliable methods available, such as 'hot set' and 'gel content', to determine the bulk crosslinking, there are a few consistent techniques to evaluate the surface crosslinking effect quantitatively. It includes hardening measurements using nanoindenter or AFM (atomic force microscopy). In this work, we present a technique for the measurement of superficial crosslinking, based on electrochemical etching of alpha irradiated polycarbonate accordingly. The mean diameter of the developed tracks nonlinearly decreases for KrF laser treatment at higher doses. The relative shrinkage of track diameters due to UV exposure before alpha irradiation, comparing to those without UV pre-radiation, indicates that UV laser makes the polymer surface hardened. The variation of mean track diameters can be strongly used to quantify the surface crosslinking.

  4. Surface effect of KrF laser exposure on ECE of alpha particle tracks in polycarbonate polymer

    International Nuclear Information System (INIS)

    Parvin, P.; Jaleh, B.; Sheikh, N.; Amiri, N.

    2005-01-01

    The optical penetration depth for polycarbonate (PC) at 308nm due to XeCl laser is about 450μm while those of KrF (248nm) and ArF (193nm) lasers become noticeably shorter to 1μm and 20nm, respectively, to show the strong superficial absorption at shorter UV wavelengths. On the other hand, KrF laser exposure on polycarbonate, at doses above 6J/cm 2 , creates the surface crosslinking. In spite of several reliable methods available, such as 'hot set' and 'gel content', to determine the bulk crosslinking, there are a few consistent techniques to evaluate the surface crosslinking effect quantitatively. It includes hardening measurements using nanoindenter or AFM (atomic force microscopy). In this work, we present a technique for the measurement of superficial crosslinking, based on electrochemical etching of alpha irradiated polycarbonate accordingly. The mean diameter of the developed tracks nonlinearly decreases for KrF laser treatment at higher doses. The relative shrinkage of track diameters due to UV exposure before alpha irradiation, comparing to those without UV pre-radiation, indicates that UV laser makes the polymer surface hardened. The variation of mean track diameters can be strongly used to quantify the surface crosslinking

  5. Compact gain saturated plasma based X-ray lasers down to 6.9nm

    Science.gov (United States)

    Rocca, Jorge; Wang, Y.; Wang, S.; Rockwood, A.; Berrill, M.; Shlyaptsev, V.

    2017-10-01

    Plasma based soft x-ray amplifiers allow many experiments requiring bright, high energy soft x-ray laser pulses to be conducted in compact facilities. We have extended the wavelength of compact gain saturated x-ray lasers to 6.89 nm in a Ni-like Gd plasma generated by a Ti:Sa laser. Gain saturated laser operation was also obtained at 7.36 nm in Ni-like Sm. Isolectronic scaling and optimization of laser pre-pulse duration allowed us to also observe strong lasing at 6.6 nm and 6.1 nm in Ni-like Tb, and amplification at 6.4 nm and 5.89 nm in Ni-like Dy. The results were obtained by transient laser heating of solid targets with traveling wave excitation at progressively increased gracing incidence angles. We show that the optimum pump angle of incidence for collisional Ni-like lasers increases linearly with atomic number from Z =42 to Z =66, reaching 43 degrees for Ni-like Dy, in good agreement with hydrodynamic/atomic physics simulations. These results will enable single-shot nano-scale imaging and other application of sub-7 nm lasers to be performed at compact facilities. Work supported by Grant DE-FG02-4ER15592 of the Department of Energy, Office of Science, and by the National Science Foundation Grant ECCS 1509925.

  6. Absolute frequency atlas from 915 nm to 985 nm based on laser absorption spectroscopy of iodine

    Science.gov (United States)

    Nölleke, Christian; Raab, Christoph; Neuhaus, Rudolf; Falke, Stephan

    2018-04-01

    This article reports on laser absorption spectroscopy of iodine gas between 915 nm and 985 nm. This wavelength range is scanned utilizing a narrow linewidth and mode-hop-free tunable diode-laser whose frequency is actively controlled using a calibrated wavelength meter. This allows us to provide an iodine atlas that contains almost 10,000 experimentally observed reference lines with an uncertainty of 50 MHz. For common lines, good agreement is found with a publication by Gerstenkorn and Luc (1978). The new rich dataset allows existing models of the iodine molecule to be refined and can serve as a reference for laser frequency calibration and stabilization.

  7. Blue laser diode (450 nm) systems for welding copper

    Science.gov (United States)

    Silva Sa, M.; Finuf, M.; Fritz, R.; Tucker, J.; Pelaprat, J.-M.; Zediker, M. S.

    2018-02-01

    This paper will discuss the development of high power blue laser systems for industrial applications. The key development enabling high power blue laser systems is the emergence of high power, high brightness laser diodes at 450 nm. These devices have a high individual brightness rivaling their IR counterparts and they have the potential to exceed their performance and price barriers. They also have a very high To resulting in a 0.04 nm/°C wavelength shift. They have a very stable lateral far-field profile which can be combined with other diodes to achieve a superior brightness. This paper will report on the characteristics of the blue laser diodes, their integration into a modular laser system suitable for scaling the output power to the 1 kW level and beyond. Test results will be presented for welding of copper with power levels ranging from 150 Watts to 600 Watts

  8. Development of blue lasers, from second harmonic generation using a Nd:YAG laser emitting at 946 nm

    International Nuclear Information System (INIS)

    Nogueira, Gustavo Bernardes

    2010-01-01

    Blue lasers have attracted much attention for applications such as blue-ray, displays and as pumped source for the Ti:sapphire laser. A Nd:YAG crystal with diffusion bonded end-caps was used together with a pump wavelength of 802,3 nm, detuned from the absorption peak at 808 nm in order to minimize the thermal lens effect by providing for a better temperature distribution inside the crystal. Using different input mirror radii, the best relation between pump waist and laser was achieved in a linear cavity and resulted in 6.75W cw (continuous wave) laser power at 946 nm and slope efficiency of 48%. In a second step, a second harmonic generation crystal for blue emission at 473 nm was inserted into different types of resonators, and the blue output power at 473 nm was measured as a function of absorbed pump power. (author)

  9. Broadband pulsed difference frequency generation laser source centered 3326 nm based on ring fiber lasers

    Science.gov (United States)

    Chen, Guangwei; Li, Wenlei

    2018-03-01

    A broadband pulsed mid-infrared difference frequency generation (DFG) laser source based on MgO-doped congruent LiNbO3 bulk is experimentally demonstrated, which employs a homemade pulsed ytterbium-doped ring fiber laser and a continuous wave erbium-doped ring fiber laser to act as seed sources. The experimental results indicate that the perfect phase match crystal temperature is about 74.5∘C. The maximum spectrum bandwidth of idler is about 60 nm with suitable polarization states of fundamental lights. The central wavelength of idlers varies from 3293 nm to 3333 nm over the crystal temperature ranges of 70.4-76∘C. A jump of central wavelength exists around crystal temperature of 72∘C with variation of about 30 nm. The conversion efficiency of DFG can be tuned with the crystal temperature and polarization states of fundamental lights.

  10. Advances in 193 nm excimer lasers for mass spectrometry applications

    Science.gov (United States)

    Delmdahl, Ralph; Esser, Hans-Gerd; Bonati, Guido

    2016-03-01

    Ongoing progress in mass analysis applications such as laser ablation inductively coupled mass spectrometry of solid samples and ultraviolet photoionization mediated sequencing of peptides and proteins is to a large extent driven by ultrashort wavelength excimer lasers at 193 nm. This paper will introduce the latest improvements achieved in the development of compact high repetition rate excimer lasers and elaborate on the impact on mass spectrometry instrumentation. Various performance and lifetime measurements obtained in a long-term endurance test over the course of 18 months will be shown and discussed in view of the laser source requirements of different mass spectrometry tasks. These sampling type applications are served by excimer lasers delivering pulsed 193 nm output of several mJ as well as fast repetition rates which are already approaching one Kilohertz. In order to open up the pathway from the laboratory to broader market industrial use, sufficient component lifetimes and long-term stable performance behavior have to be ensured. The obtained long-term results which will be presented are based on diverse 193 nm excimer laser tube improvements aiming at e.g. optimizing the gas flow dynamics and have extended the operational life the laser tube for the first time over several billion pulses even under high duty-cycle conditions.

  11. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser.

    Science.gov (United States)

    Liu, Ying; Gao, Jie; Gao, Yan; Xu, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm(2); Group B: 2 W/CW (continuous mode), 166 J/cm(2); Group C: 3W/CW, 250 J/cm(2); and Group D: 4W/CW, 333 J/cm(2). Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm(2); and Group F: 2.0 W/CW, 166 J/cm(2). The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm(2)) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue.

  12. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser

    Science.gov (United States)

    Liu, Ying; Gao, Jie; Gao, Yan; XU, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    Introduction: To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Methods: Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm2; Group B: 2 W/CW (continuous mode), 166 J/cm2; Group C: 3W/CW, 250 J/cm2; and Group D: 4W/CW, 333 J/cm2. Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm2; and Group F: 2.0 W/CW, 166 J/cm2. The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. Results: The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Conclusions: Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm2) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue. PMID:25606318

  13. Short-term clinical outcomes of laser supported periodontal treatment concept using Er,Cr:YSGG (2780nm) and diode (940 nm): a pilot study

    Science.gov (United States)

    Odor, Alin A.; Violant, Deborah; Badea, Victoria; Gutknecht, Norbert

    2016-03-01

    Backgrounds: Er,Cr:YSGG (2780nm) and diode (940 nm) lasers can be used adjacent to the conventional periodontal treatment as minimally invasive non-surgical devices. Aim: To describe the short-term clinical outcomes by combining Er,Cr:YSGG (2780nm) and diode 940 nm lasers in non-surgical periodontal treatment. Materials and methods: A total of 10 patients with periodontal disease (mild, moderate, severe) - 233 teeth and 677 periodontal pockets ranging from 4 mm to 12 mm - were treated with Er,Cr:YSGG (2780nm) and diode (940 nm) lasers in adjunct to manual and piezoelectric scaling and root planning (SRP). Periodontal parameters such as mean probing depth (PD), mean clinical attachment level (CAL) and mean bleeding on probing (BOP) were evaluated at baseline and 6 months after the laser treatment using an electronic periodontal chart. Results: At baseline, the mean PD was 4.06 ± 1.06 mm, mean CAL was 4.56 ± 1.43 mm, and mean BOP was 43.8 ± 23.84 %. At 6 months after the laser supported periodontal treatments the mean PD was 2.6 ± 0.58 mm (p laser wavelengths in adjunct to SRP offers significant improvements of periodontal clinical parameters such as PD, CAL and BOP. Keywords: Laser supported periodontal treatment concept, Er,Cr:YSGG and diode 940nm lasers, Scaling and root planning, Minimally invasive non-surgical device

  14. Femtosecond all-polarization-maintaining fiber laser operating at 1028 nm

    DEFF Research Database (Denmark)

    Olsson, R.K.; Andersen, T.V.; Leick, Lasse

    2008-01-01

    We present an effective solution for an all-polarization-maintaining modelocked femtosecond fiber laser operating at the central wavelength of 1028 nm. The laser is based on an Yb-doped active fiber. Modelocking is enabled by a semiconductor saturable absorber mirror, and the central wavelength i...... is enforced by a fiber Bragg grating. The laser is self-starting and demonstrates excellent stability gainst Q-switching. Pulse energies reach 13 nJ at 34 MHz repetition rate. External compression leads to near transform-limited pulses of 140 fs.......We present an effective solution for an all-polarization-maintaining modelocked femtosecond fiber laser operating at the central wavelength of 1028 nm. The laser is based on an Yb-doped active fiber. Modelocking is enabled by a semiconductor saturable absorber mirror, and the central wavelength...

  15. Treatment of burn scars in Fitzpatrick phototype III patients with a combination of pulsed dye laser and non-ablative fractional resurfacing 1550 nm erbium:glass/1927 nm thulium laser devices.

    Science.gov (United States)

    Tao, Joy; Champlain, Amanda; Weddington, Charles; Moy, Lauren; Tung, Rebecca

    2018-01-01

    Burn scars cause cosmetic disfigurement and psychosocial distress. We present two Fitzpatrick phototype (FP) III patients with burn scars successfully treated with combination pulsed dye laser (PDL) and non-ablative fractional lasers (NAFL). A 30-year-old, FP III woman with a history of a second-degree burn injury to the bilateral arms and legs affecting 30% body surface area (BSA) presented for cosmetic treatment. The patient received three treatments with 595 nm PDL (7 mm, 8 J, 6 ms), six with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and five with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). Treated burn scars improved significantly in thickness, texture and colour. A 33-year-old, FP III man with a history of a second-degree burn injury of the left neck and arm affecting 7% BSA presented for cosmetic treatment. The patient received two treatments with 595 nm PDL (5 mm, 7.5 J, 6 ms), four with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and two with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). The burn scars became thinner, smoother and more normal in pigmentation and appearance. Our patients' burn scars were treated with a combination of PDL and NAFL (two wavelengths). The PDL targets scar hypervascularity, the 1550 nm erbium:glass stimulates collagen remodelling and the 1927 nm thulium targets epidermal processes, particularly hyperpigmentation. This combination addresses scar thickness, texture and colour with a low side effect profile and is particularly advantageous in patients at higher risk of post-procedure hyperpigmentation. Our cases suggest the combination of 595nm PDL plus NAFL 1550 nm erbium:glass/1927 nm thulium device is effective and well-tolerated for burn scar treatment in skin of colour.

  16. 303 nm continuous wave ultraviolet laser generated by intracavity frequency-doubling of diode-pumped Pr3+:LiYF4 laser

    Science.gov (United States)

    Zhu, Pengfei; Zhang, Chaomin; Zhu, Kun; Ping, Yunxia; Song, Pei; Sun, Xiaohui; Wang, Fuxin; Yao, Yi

    2018-03-01

    We demonstrate an efficient and compact ultraviolet laser at 303 nm generated by intracavity frequency doubling of a continuous wave (CW) laser diode-pumped Pr3+:YLiF4 laser at 607 nm. A cesium lithium borate (CLBO) crystal, cut for critical type I phase matching at room temperature, is used for second-harmonic generation (SHG) of the fundamental laser. By using an InGaN laser diode array emitting at 444.3 nm with a maximum incident power of 10 W, as high as 68 mW of CW output power at 303 nm is achieved. The output power stability in 4 h is better than 2.85%. To the best of our knowledge, this is high efficient UV laser generated by frequency doubling of an InGaN laser diode array pumped Pr3+:YLiF4 laser.

  17. Fixed, low radiant exposure vs. incremental radiant exposure approach for diode laser hair reduction: a randomized, split axilla, comparative single-blinded trial.

    Science.gov (United States)

    Pavlović, M D; Adamič, M; Nenadić, D

    2015-12-01

    Diode lasers are the most commonly used treatment modalities for unwanted hair reduction. Only a few controlled clinical trials but not a single randomized controlled trial (RCT) compared the impact of various laser parameters, especially radiant exposure, onto efficacy, tolerability and safety of laser hair reduction. To compare the safety, tolerability and mid-term efficacy of fixed, low and incremental radiant exposures of diode lasers (800 nm) for axillary hair removal, we conducted an intrapatient, left-to-right, patient- and assessor-blinded and controlled trial. Diode laser (800 nm) treatments were evaluated in 39 study participants (skin type II-III) with unwanted axillary hairs. Randomization and allocation to split axilla treatments were carried out by a web-based randomization tool. Six treatments were performed at 4- to 6-week intervals with study subjects blinded to the type of treatment. Final assessment of hair reduction was conducted 6 months after the last treatment by means of blinded 4-point clinical scale using photographs. The primary endpoint was reduction in hair growth, and secondary endpoints were patient-rated tolerability and satisfaction with the treatment, treatment-related pain and adverse effects. Excellent reduction in axillary hairs (≥ 76%) at 6-month follow-up visit after receiving fixed, low and incremental radiant exposure diode laser treatments was obtained in 59% and 67% of study participants respectively (Z value: 1.342, P = 0.180). Patients reported lower visual analogue scale (VAS) pain score on the fixed (4.26) than on the incremental radiant exposure side (5.64) (P diode laser treatments were less painful and better tolerated. © 2015 European Academy of Dermatology and Venereology.

  18. Experimental Studies of Simultaneous 351 nm and 527 nm Laser Beam Interactions in a Long Scalelength Plasma

    International Nuclear Information System (INIS)

    Moody, J D; Divol, L; Glenzer, S H; MacKinnon, A J; Froula, D H; Gregori, G; Kruer, W L; Suter, L J; Williams, E A; Bahr, R; Seka, W

    2003-01-01

    We describe experiments investigating the simultaneous backscattering from 351 nm (3w) and 527 nm (2w) interaction beams in a long scalelength laser-produced plasma for intensities (le) 1 x 10 15 W/cm 2 . Measurements show comparable scattering fractions for both color probe beams. Time resolved spectra of stimulated Raman and Brillouin scattering (SRS and SBS) indicate the effects of laser intensity and smoothing as well as plasma composition and parameters on the scattering levels

  19. Retinal hemorrhage thresholds for Q-switched neodymium-Yag laser exposures

    Energy Technology Data Exchange (ETDEWEB)

    Blankenstein, M.F.; Zuclich, J.; Allen, R.G.; Davis, H.; Thomas, S.J.; Harrison, R.F.

    1986-07-01

    Thresholds for retinal vitreal and contained hemorrhages were determined for 1064 nm laser light at 30-nsec and 4-nsec pulsewidths. Rhesus monkeys received graded exposures from a neodymium-yag laser onto either the macular or extramacular region of the retina. Contained hemorrhages appeared as concentric ring structures with white punctate centers. The vitreal hemorrhage was characterized by the presence of choroidal blood in the vitreal chamber at the exposure site. The 30-nsec contained hemorrhage threshold (ED50) was 1.7 mJ on the macula and 2.1 mJ for an extramacular exposure. The 30-nsec vitreal hemorrhage macular threshold was 2.3 mJ, and the extramacular threshold was 6.6 mJ. The threshold for the 4-nsec pulsewidths to produce a hemorrhage (vitreal or contained) on the retina (macula or extramacular) was 340 microJ.

  20. Retinal-hemorrhage thresholds for Q-switched neodymium-YAG laser exposures

    Energy Technology Data Exchange (ETDEWEB)

    Blankenstein, M.F.; Zuclich; Allen, R.G.; Davis; Thomas, S.J.

    1986-07-01

    Thresholds for retinal vitreal and contained hemorrhages were determined for 1064-nm laser light at 30-ns and 4-ns pulsewidths. Rhesus monkeys received graded exposures from a neodymium-YAG laser onto either the macular or extramacular region of the retina. Contained hemorrhages appeared as concentric-ring structures with white punctuate centers. The vitreal hemorrhage was characterized by the presence of choroidal blood in the vitreal chamber at the exposure site. The 30-ns contained-hemorrhage threshold (ED50) was 1.7 mJ on the macula and 2.1 mJ for an extramacular exposure. The 30-ns vitreal-hemorrhage macular threshold was 2.3 mJ, and the extramacular threshold was 6.6 Mj. The threshold for the 4-ns pulse widths to produce a hemorrhage (vitreal or contained) on the retina (macula or extramacular) was 340 uJ.

  1. Treatment of oral lichen planus using 308-nm excimer laser.

    Science.gov (United States)

    Liu, Wei-Bing; Sun, Li-Wei; Yang, Hua; Wang, Yan-Fei

    2017-09-01

    Oral lichen planus (OLP) is a chronic inflammatory disease, has prolonged courses, repeated attacks and resistance to treatment. The traditional narrow spectrum UVB treatment has an established efficacy on skin lichen planus, and high safety. However, most of ultraviolet phototherapy devices have a huge volume, thereby cannot be used in the treatment of OLP. Lymphocytic infiltration is evident in the lesions of lichen planus, and the direct irradiation of 308-nm excimer laser can induce apoptosis of the T lymphocytes in skin lesions, thereby has a unique therapeutic effect on the diseases involving T lymphocytes. This study aims to investigate the efficacy of 308-nm excimer laser in the treatment of OLP. A total of six OLP patients were enrolled into this study, and further pathological diagnosis was conducted, then 308-nm excimer laser was used in the treatment. The efficacy of 308-nm excimer laser in the treatment of OLP was satisfactory. The clinical symptoms of five patients were significantly improved. In two patients, the erosion surface based on congestion and the surrounding white spots completely disappeared, and clinical recovery was achieved. Three patients achieved partial remission, that is, the erosion surface healed, congestion and white spot area shrunk by more than 1/2 of the primary skin lesions. In the remaining one patient, the erosion surface had not completely healed after treatment, and congestion and white spot area shrunk by less than 1/2 of the primary skin lesions. Only one patients had developed mild pain during the treatment, and this symptom alleviated by itself. The 308-nm excimer laser therapy can serve as a safe and effective treatment for OLP. © 2017 Wiley Periodicals, Inc.

  2. A diode-end-pumped Nd:GYSGG continuous wave laser at 1104 nm

    International Nuclear Information System (INIS)

    Shen, B J; Kang, H X; Zhang, C G; Chen, P; Gao, R L; Liang, J; Gao, H J; Zhang, Q L; Sun, D L; Yin, S T; Luo, J Q

    2013-01-01

    The continuous wave (CW) laser performance of Nd:GYSGG at 1104 nm is investigated for the first time, to our knowledge. A CW laser output power of 4.7 W is obtained when the pump power of the 808 nm fiber coupled laser diode is 19.1 W, corresponding to a conversion efficiency of 24.6% and slope efficiency of 37%. (paper)

  3. Gain optimization and saturation of the Xe III 109 nm auger laser

    International Nuclear Information System (INIS)

    Macklin, J.J.; Sher, M.H.; Barty, C.P.J.; King, D.A.; Yin, G.Y.; Harris, S.E.; Young, J.F.

    1988-01-01

    The authors describe the construction and operation of a 109 nm, photoionization-pumped, single-pass laser in Xe III. The laser is pumped by soft x-rays emitted from a laser-produced plasma in a traveling-wave geometry. Using a 3.5 J, 300 psec, 1064 nm laser pump pulse, they measure a small-signal gain coefficient of 4.4 cm -1 and a total small signal gain of exp(40). The laser is fully saturated and produces an output energy of 20 μJ in a beam with 10 mrad divergence

  4. 20 W continuous-wave cladding-pumped Nd-doped fiber laser at 910 nm.

    Science.gov (United States)

    Laroche, M; Cadier, B; Gilles, H; Girard, S; Lablonde, L; Robin, T

    2013-08-15

    We demonstrate a double-clad fiber laser operating at 910 nm with a record power of 20 W. Laser emission on the three-level scheme is enabled by the combination of a small inner cladding-to-core diameter ratio and a high brightness pump source at 808 nm. A laser conversion efficiency as high as 44% was achieved in CW operating regime by using resonant fiber Bragg reflectors at 910 nm that prevent the lasing at the 1060 nm competing wavelength. Furthermore, in a master oscillator power-amplifier scheme, an amplified power of 14.8 W was achieved at 914 nm in the same fiber.

  5. Diode-pumped thin-disk Nd:GdVO4 laser at 893 nm

    International Nuclear Information System (INIS)

    Li, Y L; Fu, X H; Wang, A G

    2011-01-01

    We report for the first time a Nd:GdVO 4 laser operating in a continuous wave (CW) on the quasi-three-level laser at 893 nm, based on the 4 F 3/2 – 4 I 9/2 transition, generally used for a 912 nm emission. The use of a pump module with 16 passes through the crystal allowed the realization of a Nd:GdVO 4 thin-disk laser with 157 mW of CW output power at 893 nm. Moreover, intracavity second-harmonic generation (SHG) has also been achieved with a power of 23 mW at 447 nm by using a BiB 3 O 6 (BiBO) nonlinear crystal

  6. Combination of 595-nm pulsed dye laser, long-pulsed 755-nm alexandrite laser, and microdermabrasion treatment for keratosis pilaris: retrospective analysis of 26 Korean patients.

    Science.gov (United States)

    Lee, Sang Ju; Choi, Min Ju; Zheng, Zhenlong; Chung, Won Soon; Kim, Young Koo; Cho, Sung Bin

    2013-06-01

    Keratosis pilaris (KP) has beenpresented as small keratotic follicular papules with or without surrounding erythema. Various treatments with laser or light therapy have been used for the management of KP with various clinical outcomes. In the present study, we investigated the efficacy and safety of a combination therapy for KP. A total of 29 anatomical sites with KP in 26 patients were treated using a 595-nm pulsed dye laser (PDL) with nonpurpuragenic fluences, a long-pulsed 755-nm alexandrite laser, and microdermabrasion. Clinical improvement was assessed by comparing preand posttreatment clinical photographs and patient satisfaction rates. Evaluation of the clinical results three months after the treatments showed that 12 of the 29 anatomical sites (41.4%) demonstrated Grade 3 clinical improvement, ten (34.5%) had Grade 2 clinical improvement, four (13.8%) showed Grade 1 improvement, and three (10.3%) showed Grade 4 improvement. We observed that KP lesions improved not only in erythema and skin texture, but also in brownish dyschromias. Potential adverse events were not observed, except prolonged posttherapy scaling. Our observations demonstrate that combination therapy using a 595-nm PDL, a long-pulsed 755-nm alexandrite laser, and microdermabrasion can have a positive therapeutic effect on KP.

  7. Building blocks for future detectors: Silicon test masses and 1550 nm laser light

    International Nuclear Information System (INIS)

    Schnabel, R; Britzger, M; Burmeister, O; Danzmann, K; Duck, J; Eberle, T; Friedrich, D; Luck, H; Mehmet, M; Steinlechner, S; Willke, B; Brueckner, F; Nawrodt, R

    2010-01-01

    Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the Einstein-Telescope, will involve a considerable sensitivity increase. The combination of 1550 nm laser radiation and crystalline silicon test masses at low temperatures might be important ingredients in order to achieve the sensitivity goal. Here we compare some properties of the fused silica and silicon test mass materials relevant for decreasing the thermal noise in future detectors as well as the recent technology achievements in the preparation of laser radiation at 1064 nm and 1550 nm relevant for decreasing the quantum noise. We conclude that silicon test masses and 1550 nm laser light have the potential to form the future building blocks of gravitational wave detection.

  8. Three hundred patients treated with ultrapulsed 980 nm diode laser for skin disorders

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2016-01-01

    Full Text Available The use of lasers in skin diseases is quite common. In contrast to other laser types, medical literature about 980 nm ultrapulsed diode laser is sparse in dermatology. Herein, we report the use of ultrapulsed diode 980 nm laser in 300 patients with vascular lesions, cysts and pseudocysts, infectious disease, and malignant tumors. This laser is a versatile tool with excellent safety and efficacy in the hands of the experienced user.

  9. Three Hundred Patients Treated with Ultrapulsed 980 nm Diode Laser for Skin Disorders

    Science.gov (United States)

    Wollina, Uwe

    2016-01-01

    The use of lasers in skin diseases is quite common. In contrast to other laser types, medical literature about 980 nm ultrapulsed diode laser is sparse in dermatology. Herein, we report the use of ultrapulsed diode 980 nm laser in 300 patients with vascular lesions, cysts and pseudocysts, infectious disease, and malignant tumors. This laser is a versatile tool with excellent safety and efficacy in the hands of the experienced user. PMID:27688445

  10. Spectroscopic properties and laser performance at 1,066 nm of a new laser crystal Nd:GdTaO4

    Science.gov (United States)

    Peng, Fang; Yang, Huajun; Zhang, Qingli; Luo, Jianqiao; Liu, Wenpeng; Sun, Dunlu; Dou, Renqin; Sun, Guihua

    2015-03-01

    A new laser medium Nd3+:GdTaO4 single crystal with high optical quality was grown successfully by the Czochralski method, and its high-efficiency laser operation at 1,066 nm was demonstrated for the first time. The absorption cross section of the crystal at 808 nm is 5.098 × 10-20 cm2, and the full width at half maximum of this absorption band is about 6 nm. Spectral properties are investigated by Judd-Ofelt theory. The stimulated emission cross section at 1,066 nm is 3.9 × 10-19 cm2, and the fluorescence lifetime of 4F3/2 level is 178.4 μs. A diode end-pumped Nd:GdTaO4 laser at 1,066 nm with the maximum output power of 2.5 W is achieved in the continuous-wave mode. The optical-to-optical conversion efficiency and slope efficiency are 34.6 and 36 %, respectively. In addition, the fluorescence branching ratio of 4F3/2 → 4I9/2 transition reaches 44.4 %, indicating that Nd:GdTaO4 may be an efficient laser medium at 920 nm. All the results demonstrate that Nd:GdTaO4 crystal is a good candidate for laser diode-pumped laser material.

  11. Comparison of Pain Response of Patients Undergoing Panretinal Photocoagulation for Proliferative Diabetic Retinopathy: 532 nm Standard Laser vs. Multispot Pattern Scan Laser

    Directory of Open Access Journals (Sweden)

    Göktuğ Seymenoğlu

    2013-08-01

    Full Text Available Purpose: To compare pain response of patients undergoing panretinal photocoagulation (PRP for proliferative diabetic retinopathy (PDR using 532 nm standard laser versus multispot pattern scan laser and to evaluate the relationship between pain response and patient characteristics. Material and Method: Thirty-five patients had PRP with the Pascal system in a single session, while other 35 patients had PRP with conventional laser in 2 sessions. Parameters used in conventional laser were as follows: spot size 200 µm, exposure time 0.2 s, and power sufficient to produce visible grey-white burns. We used same spot size, 20-30 ms exposure time, and higher levels of laser power in order to get a similar endpoint in the Pascal system. The patients were required to evaluate the severity of pain on a visual analog scale (VAS and verbally 5 minutes after PRP with Pascal and 5 minutes after the first session of PRP with conventional laser. The relationship between pain experienced and patient characteristics was evaluated. Results: At baseline, both groups did not differ significantly (p >0.05, for all with respect to sex, age, duration of diabetes, most recent HbA1c, treatment regimen, or patient experience. The patients in the Pascal group had a mean pain score of 0.55±0.70 on verbal scale and 1.54±1.22 on VAS compared to 2.17±1.18 and 5.54±3.28, respectively in the conventional laser group which was, statistically, significantly different in both scales (p<0.05. Discussion: Our study confirms that new generation pattern scanning photocoagulators satisfactorily decrease the pain by shortening the exposure time while increasing the laser power. (Turk J Ophthalmol 2013; 43: 221-4

  12. Continuous-wave, single-frequency 229  nm laser source for laser cooling of cadmium atoms.

    Science.gov (United States)

    Kaneda, Yushi; Yarborough, J M; Merzlyak, Yevgeny; Yamaguchi, Atsushi; Hayashida, Keitaro; Ohmae, Noriaki; Katori, Hidetoshi

    2016-02-15

    Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the fourth harmonic using two successive second-harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Conversion efficiency from 458 nm to 229 nm was more than 34%. By applying a tapered amplifier (TA) as a fundamental source, we demonstrated magneto-optical trapping of all stable Cd isotopes including isotopes Cd111 and Cd113, which are applicable to optical lattice clocks.

  13. Diode-side-pumped 131 W, 1319 nm single-wavelength cw Nd:YAG laser.

    Science.gov (United States)

    Haiyong, Zhu; Ge, Zhang; Chenghui, Huang; Yong, Wei; Lingxiong, Huang; Jing, Chen; Weidong, Chen; Zhenqiang, Chen

    2007-01-20

    A diode-side-pumped high-power 1319 nm single-wavelength Nd:YAG continuous wave (cw) laser is described. Through reasonable coating design of the cavity mirrors, the 1064 nm strongest line as well as the 1338 nm one have been successfully suppressed. The laser output powers corresponding to four groups of different output couplers operating at 1319 nm single wavelength have been compared. The output coupler with the transmission T=5.3% has the highest output power, and a 131 W cw output power was achieved at the pumping power of 555 W. The optical-optical conversion efficiency is 23.6%, and the slope efficiency is 46%. The output power is higher than the total output power of the dual-wavelength laser operating at 1319 nm and 1338 nm in the experiment.

  14. Comparative analysis of the effect of the GaAlAs laser irradiation in 780 nm and 660 nm in the hypersensitive dentin; Analise comparativa do efeito da irradiacao do laser de GaAlAs em 780 nm e 660 nm na hipersensibilidade dentinaria

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Sun Chien

    2003-07-01

    This study was to evaluate and compare the effects of the low intensity in laser radiation among GaAlAs 780 nm and GaAlAs 660 nm. The main proposal is to verify if there is any difference of the effects or results in low intensity laser application treatment of hypersensitive dentin, keeping the same parameters, only differing in wavelength. The samples were distributed in two groups. Group A 90 cases, treated with GaAlAs 780 nm and group B irradiated with GaAlAs 660 nm with a total of 76 cases analyzed. The results of application with GaAlAs 660 nm and GaAlAs 780 nm do not differ statistically. Which means using any one of the irradiation gives the same results. However can be noted that the response of reduction of hypersensitivity is faster with the radiation of GaAlAs 780 nm, but the results after three applications is the same for both types of radiation. (author)

  15. TUNABLE DIODE LASER MEASUREMENTS OF NO2 NEAR 670 NM AND 395 NM. (R823933)

    Science.gov (United States)

    Two single-mode diode lasers were used to record high-resolution absorption spectra of NO2 (dilute in Ar) near 670.2 and 394.5 nm over a range of temperatures (296 to 774 K) and total pressures (2.4 x 10(-2) to 1 atm). A commercial InGaAsP laser was tuned 1.3 cm(-1) at a repetiti...

  16. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    Energy Technology Data Exchange (ETDEWEB)

    Kotoku, Y; Kato, J; Akashi, G; Hirai, Y [Department of Operative Dentistry, Tokyo Dental College, 1-2-2, Masago, Mihama-ku, Chiba, 261-8502 (Japan); Ishihara, K [Department of Microbiology, Tokyo Dental College, 1-2-2, Masago, Mihama-ku, Chiba, 261-8502 (Japan)

    2009-05-15

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm{sup 2}. The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm{sup 2}. The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis.

  17. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    International Nuclear Information System (INIS)

    Kotoku, Y; Kato, J; Akashi, G; Hirai, Y; Ishihara, K

    2009-01-01

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm 2 . The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm 2 . The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis

  18. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    Science.gov (United States)

    Kotoku, Y.; Kato, J.; Akashi, G.; Hirai, Y.; Ishihara, K.

    2009-05-01

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm2. The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm2. The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis.

  19. Continuous-wave single-frequency laser with dual wavelength at 1064 and 532 nm.

    Science.gov (United States)

    Zhang, Chenwei; Lu, Huadong; Yin, Qiwei; Su, Jing

    2014-10-01

    A continuous-wave high-power single-frequency laser with dual-wavelength output at 1064 and 532 nm is presented. The dependencies of the output power on the transmission of the output coupler and the phase-matching temperature of the LiB(3)O(5) (LBO) crystal are studied. An output coupler with transmission of 19% is used, and the temperature of LBO is controlled to the optimal phase-matching temperature of 422 K; measured maximal output powers of 33.7 W at 1064 nm and of 1.13 W at 532 nm are obtained with optical-optical conversion efficiency of 45.6%. The laser can be single-frequency operated stably and mode-hop-free, and the measured frequency drift is less than 15 MHz in 1 min. The measured Mx2 and My2 for the 1064 nm laser are 1.06 and 1.09, respectively. The measured Mx2 and My2 for the 532 nm laser are 1.12 and 1.11, respectively.

  20. Laser at 532 nm by intracavity frequency-doubling in BBO

    Science.gov (United States)

    Yuan, Xiandan; Wang, Jinsong; Chen, Yongqi; Wu, Yulong; Qi, Yunfei; Sun, Meijiao; Wang, Qi

    2017-06-01

    A simple and compact linear resonator green laser at 532 nm is generated by intracavity frequency-doubling of a diode-side-pumped acousto-optically (AO) Q-switched Nd:YAG laser at 1064 nm. Two acousto-optic Q-switches were placed orthogonally with each other to improve the hold-off capacity. As high as 214 W of continuous-wave (CW) and 154 W of quasi-continuous-wave (QCW) output power at 1064 nm were obtained when the pumping power was 1598 W. The type I phase-matched BBO crystal was used as the nonlinear medium in the second harmonic generation. A green laser with an average output power of 37 W was obtained at a repetition rate of 20 kHz and a pulse width of 54 ns, which corresponds to pulse energy of 1.85 mJ per pulse and a peak power 34.26 kW, respectively. Project supported by the Beijing Engineering Technology Research Center of All-Solid-State Lasers Advanced Manufacturing, the National High Technology Research and Development Program of China (No. 2014AA032607), and the National Natural Science Foundation of China (Nos. 61404135, 61405186, 61308032, 61308033).

  1. 308-nm excimer laser for the treatment of alopecia areata.

    Science.gov (United States)

    Al-Mutairi, Nawaf

    2007-12-01

    Alopecia areata is loss of hair from localized or diffuse areas of hair-bearing area of the skin. Recently there are reports of efficacy of the 308-nm excimer radiation for this condition. To study the effect of the 308-nm excimer laser in the treatment of alopecia areata. Eighteen patients with 42 recalcitrant patches (including 1 adult with alopecia totalis) were enrolled in this study. The lesions were treated with the 308-nm excimer laser twice a week for a period of 12 weeks; one lesion on each patient was left as a control for comparison. There were 7 males and 11 females in this study. Regrowth of hair was observed in 17 (41.5%) patches. Thirteen of the 18 lesions in scalp showed a complete regrowth of hair. The extremity regions failed to show a response. Atopic diatheses had an unfavorable effect on the outcome in our patients. The 308-nm excimer laser is an effective therapeutic option for patchy alopecia areata of the scalp and for some cases with patchy alopecia areata of the beard area. It does not work for patchy alopecia areata of the extremities.

  2. High efficiency single frequency 355 nm all-solid-state UV laser

    International Nuclear Information System (INIS)

    Xie, Xiaobing; Wei, Daikang; Ma, Xiuhua; Li, Shiguang; Liu, Jiqiao; Zhu, Xiaolei; Chen, Weibiao

    2016-01-01

    A novel conductively cooled high energy single-frequency 355 nm all-solid-state UV laser is presented based on sum-frequency mixing technique. In this system, a pulsed seeder laser at 1064 nm wavelength, modulated by an AOM, is directly amplified by the cascaded multi-stage hybrid laser amplifiers, and two LBO crystals are used for the SHG and SFG, finally a maximum UV pulse energy of 226 mJ at 355 nm wavelength is achieved with frequency-tripled conversion efficiency as high as 55%, the pulse width is around 12.2 ns at the repetition frequency of 30 Hz. The beam quality factor M 2 of the output UV laser is measured to be 2.54 and 2.98 respectively in two orthogonal directions. (paper)

  3. The generation of a continuous-wave Nd:YVO4/LBO laser at 543 nm by direct in-band diode pumping at 888 nm

    International Nuclear Information System (INIS)

    Fu, S C; Wang, X; Chu, H

    2013-01-01

    We report the generation of a green laser at 543 nm by intracavity frequency doubling of the continuous-wave (cw) laser operation of a 1086 nm Nd:YVO 4 laser under 888 nm diode pumping into the emitting level 4 F 3/2 . An LiB 3 O 5 (LBO) crystal, cut for critical type I phase matching at room temperature, is used for the laser second-harmonic generation. At an incident pump power of 17.8 W, as high as 4.53 W cw output power at 543 nm is achieved. The optical-to-optical conversion efficiency is up to 25.4%, and the fluctuation of the green output power is better than 2.3% in a 30 min period. (paper)

  4. Biostimulative effects of 809 nm diode laser on cutaneous skin wounds

    Science.gov (United States)

    Solmaz, Hakan; Gülsoy, Murat; Ülgen, Yekta

    2015-03-01

    The use of low-level laser therapy (LLLT) for therapeutic purposes in medicine has become widespread recently. There are many studies in literature supporting the idea of therapeutic effects of laser irradiation on biological tissues. The aim of this study is to investigate the biostimulative effect of 809nm infrared laser irradiation on the healing process of cutaneous incisional skin wounds. 3-4 months old male Wistar Albino rats weighing 300 to 350 gr were used throughout this study. Lowlevel laser therapy was applied through local irradiation of 809nm infrared laser on open skin incisional wounds of 1 cm length. Each animal had six identical incisions on their right and left dorsal region symmetrical to each other. The wounds were separated into three groups of control, 1 J/cm2 and 3 J/cm2 of laser irradiation. Two of these six wounds were kept as control group and did not receive any laser application. Rest of the incisions was irradiated with continuous diode laser of 809nm in wavelength and 20mW power output. Two of them were subjected to laser irradiation of 1 J/cm2 and the other two were subjected to laser light with energy density of 3 J/cm2. Biostimulation effects of irradiation were studied by means of tensile strength tests and histological examinations. Wounded skin samples were morphologically examined and removed for mechanical and histological examinations at days 3, 5 and 7 following the laser applications. Three of the six fragments of skin incisions including a portion of peripheral healthy tissue from each animal were subjected to mechanical tests by means of a universal tensile test machine, whereas the other three samples were embedded in paraffin and stained with hematoxylin and eosin for histological examinations. The findings of the study show that tissue repair following laser irradiation of 809nm has been accelerated in terms of tissue morphology, strength and cellular content. These results seem to be consistent with the results of many

  5. Green high-power tunable external-cavity GaN diode laser at 515 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2016-01-01

    A 480 mW green tunable diode laser system is demonstrated for the first time to our knowledge. The laser system is based on a GaN broad-area diode laser and Littrow external-cavity feedback. The green laser system is operated in two modes by switching the polarization direction of the laser beam...... incident on the grating. When the laser beam is p-polarized, an output power of 50 mW with a tunable range of 9.2 nm is achieved. When the laser beam is s-polarized, an output power of 480 mW with a tunable range of 2.1 nm is obtained. This constitutes the highest output power from a tunable green diode...... laser system....

  6. Effect of long- and short-term exposure to laser light at 1070 nm on growth of Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Aabo, Thomas; Perch-Nielsen, Ivan R.; Dam, Jeppe Seidelin

    2010-01-01

    The effect of a 1070-nm continuous and pulsed wave ytterbium fiber laser on the growth of Saccharomyces cerevisiae single cells is investigated over a time span of 4 to 5 h. The cells are subjected to optical traps consisting of two counterpropagating plane wave beams with a uniform flux along th...

  7. Future directions in 980-nm pump lasers: submarine deployment to low-cost watt-class terrestrial pumps

    Science.gov (United States)

    Gulgazov, Vadim N.; Jackson, Gordon S.; Lascola, Kevin M.; Major, Jo S.; Parke, Ross; Richard, Tim; Rossin, Victor V.; Zhang, Kai

    1999-09-01

    The demands of global bandwidth and distribution are rising rapidly as Internet usage grows. This fundamentally means that more photons are flowing within optical cables. While transmitting sources launches some optical power, the majority of the optical power that is present within modern telecommunication systems originates from optical amplifiers. In addition, modern optical amplifiers offer flat optical gain over broad wavelength bands, thus making possible dense wavelength de-multiplexing (DWDM) systems. Optical amplifier performance, and by extension the performance of the laser pumps that drive them, is central to the future growth of both optical transmission and distribution systems. Erbium-doped amplifiers currently dominate optical amplifier usage. These amplifiers absorb pump light at 980 nm and/or 1480 nm, and achieve gain at wavelengths around 1550 nm. 980 nm pumps achieve better noise figures and are therefore used for the amplification of small signals. Due to the quantum defect, 1480 nm lasers deliver more signal photon per incident photon. In addition, 1480 nm lasers are less expensive than 980 nm lasers. Thus, 1480 nm pump lasers are used for amplification in situations where noise is not critical. The combination of these traits leads to the situation where many amplifiers contain 980 nm lasers to pump the input section of the Er- doped fiber with 1480 nm lasers being used to pump the latter section of Er fiber. This can be thought of as using 980 nm lasers to power an optical pre-amplifier with the power amplification function being pump with 1480 nm radiation. This paper will focus on 980 nm pump lasers and the impact that advances in 980 nm pump technology will have on optical amplification systems. Currently, 980 nm technology is rapidly advancing in two areas, power and reliability. Improving reliability is becoming increasingly important as amplifiers move towards employing more pump lasers and using these pump lasers without redundancy

  8. Long-term efficacy of linear-scanning 808 nm diode laser for hair removal compared to a scanned alexandrite laser.

    Science.gov (United States)

    Grunewald, Sonja; Bodendorf, Marc Oliver; Zygouris, Alexander; Simon, Jan Christoph; Paasch, Uwe

    2014-01-01

    Alexandrite and diode lasers are commonly used for hair removal. To date, the available spot sizes and repetition rates are defining factors in terms of penetration depth, treatment speed, and efficacy. Still, larger treatment areas and faster systems are desirable. To compare the efficacy, tolerability, and subject satisfaction of a continuously linear-scanning 808 nm diode laser with an alexandrite 755 nm laser for axillary hair removal. A total of 31 adults with skin types I-IV received 6 treatments at 4-week intervals with a 755 nm alexandrite laser (right axilla) and a continuously linear-scanning 808 nm diode laser (left axilla). Axillary hair density was assessed using a computerized hair detection system. There was a significant reduction in axillary hair after the 6th treatment (P lasers was not significant, but both were persistant at 18 months follow-up (left: hair clearance of 73.71%; right: hair clearance of 71.90%). Erythema and perifollicular edema were more common after alexandrite laser treatment, but all side effects were transient. While 62.50% of patients reported more pain in response to treatment with the new diode laser, all patients rated treatment with either laser tolerable. Treatment with either the alexandrite or the linear-scanning diode laser results in significant, comparable, persistent (at least 18 months) axillary hair reduction among individuals with skin types I-IV. © 2013 Wiley Periodicals, Inc.

  9. 308-nm excimer laser in endodontics

    Science.gov (United States)

    Liesenhoff, Tim

    1992-06-01

    Root canal preparation was performed on 20 extracted human teeth. After opening the coronal pulp, the root canals were prepared by 308 nm excimer laser only. All root canals were investigated under SEM after separation in the axial direction. By sagittal separation of the mandibles of freshly slaughtered cows, it was possible to get access to the tissues and irradiate under optical control. Under irradiation of excimer laser light, tissue starts to fluoresce. It was possible to demonstrate that each tissue (dentin, enamel, bone, pulpal, and connective tissue) has a characteristic spectral pattern. The SEM analyses showed that it is well possible to prepare root canals safely. All organic soft tissue has been removed by excimer laser irradiation. There was no case of via falsa. The simultaneous spectroscopic identification of the irradiated tissue provides a safe protection from overinstrumentation. First clinical trials on 20 patients suffering of chronical apical parodontitis have been carried out successfully.

  10. Laser spectroscopy of the products of photoevaporation with a short-wavelength (λ = 193 nm) excimer laser

    International Nuclear Information System (INIS)

    Gochelashvili, K S; Zemskov, M E; Evdokimova, O N; Mikhkel'soo, V T; Prokhorov, A M

    1999-01-01

    An excimer laser spectrometer was designed and constructed. It consists of a high-vacuum interaction chamber, a short-wavelength (λ = 193 nm) excimer ArF laser used for evaporation, a probe dye laser pumped by an XeCl excimer laser, and a system for recording a laser-induced fluorescence signal. This spectrometer was used to investigate nonthermal mechanisms of photoevaporation of a number of wide-gap dielectrics. (laser applications and other topics in quantum electronics)

  11. Efficient generation of 509 nm light by sum-frequency mixing between two tapered diode lasers

    DEFF Research Database (Denmark)

    Tawfieq, Mahmoud; Jensen, Ole Bjarlin; Hansen, Anders Kragh

    2015-01-01

    We demonstrate a concept for visible laser sources based on sum-frequency generation of beam com- bined tapered diode lasers. In this specific case, a 1.7 W sum-frequency generated green laser at 509 nm is obtained, by frequency adding of 6.17 W from a 978 nm tapered diode laser with 8.06 W from...... a 1063 nm tapered diode laser, inside a periodically poled MgO doped lithium niobate crystal. This corresponds to an optical to optical conversion ef fi ciency of 12.1%. As an example of potential applica- tions, the generated nearly diffraction-limited green light is used for pumping a Ti:sapphire laser......, thus demonstrating good beam quality and power stability. The maximum output powers achieved when pumping the Ti:sapphire laser are 226 mW (CW) and 185 mW (mode-locked) at 1.7 W green pump power. The optical spectrum emitted by the mode-locked Ti:sapphire laser shows a spectral width of about 54 nm...

  12. Diode-laser-pumped high efficiency continuous-wave operation at 912 nm laser in Nd:GdVO4 crystal

    International Nuclear Information System (INIS)

    Yu, X; Chen, F; Gao, J; Li, X D; Yan, R P; Zhang, K; Yu, J H; Zhang, Z H

    2009-01-01

    High efficiency operation on continuous-wave (cw) 912 nm laser at room temperature in Nd:GdVO 4 crystal pumped by 808 nm diode-laser is reported in this letter. The maximum output power of 8.0 W was obtained at the incident un-polarized pump power of 47.0 W, giving the corresponding optical-to-optical conversion efficiency of 17.0% and the average slope efficiency of 22.9%. Further tests show that the lasing threshold is reduced and the efficiency is increased evidently when using the π-polarized 808 nm pump source. 4.8 W 912 nm laser was achieved at the polarized pump power of 21.8 W, optical-to-optical conversion efficiency is increased to 22.0% and average slope efficiency is up to 33.6%

  13. Treatment of keloid scars with a 1210-nm diode laser in an animal model.

    Science.gov (United States)

    Philandrianos, Cécile; Bertrand, Baptiste; Andrac-Meyer, Lucile; Magalon, Guy; Casanova, Dominique; Kerfant, Nathalie; Mordon, Serge

    2015-12-01

    A temperature increase can improve wound healing by activation of heat shock protein 70 and stimulation of fibroblasts. Since keloids are a dysfunction of collagen fiber synthesis and organization, this study aimed to evaluate if a 1,210 nm diode laser could have effects in a new animal model of keloid scars. A total of 39 nude mice were used for this study. Phototypes IV and V human keloids were grafted into their backs and after 1 month of healing, the mice were divided into four groups: Control, Laser, Resection, Resection/Laser. In the Laser group, the keloids were treated with a 1,210-nm diode-laser with the following parameters: 4 W; 10 seconds; fluence: 51 J/cm(2) ; spot: 18.9 × 3.7 mm(2) . In the Resection group, surgical intra-lesional excision was performed. In the Resection/Laser group, keloids were treated with the 1,210-nm laser-diode after surgical intra-lesional excision. Temperature measurements were made during the laser treatment. Clinical examination and histological study were performed on the day of treatment and 1 month, 2 months, and 3 months later. Mean temperature measurement was of 44.8°C (42-48°) in the Laser groups. No healing complications or keloid proliferation was observed in any group. Keloid histologic characters were confirmed in all grafts. No histologic particularity was observed in the laser groups in comparison with the Control and Resection groups. First, this keloid animal model appears to be adapted for laser study. Secondly, the 1,210-nm diode laser does not induce keloid thermal damage in vivo. Further studies with different 1,210-nm laser diode parameters should be performed in order to observe significant effects on keloids. © 2015 Wiley Periodicals, Inc.

  14. Effect of 940 nm low-level laser therapy on osteogenesis in vitro

    Science.gov (United States)

    Jawad, Mohammed Mahmood; Husein, Adam; Azlina, Ahmad; Alam, Mohammad Khursheed; Hassan, Rozita; Shaari, Rumaizi

    2013-12-01

    Bone regeneration is essential in medical treatment, such as in surgical bone healing and orthodontics. The aim of this study is to examine the effect of different powers of 940 nm diode low-level laser treatment (LLLT) on osteoblast cells during their proliferation and differentiation stages. A human fetal osteoblast cell line was cultured and treated with LLLT. The cells were divided into experimental groups according to the power delivered and periods of exposure per day for each laser power. The (3-(4,5-dimethylthiazol-2yl)-2,5 diphenyl tetrazolium bromide) (MTT) assay was used to determine cell proliferation. Both alkaline phosphatase and osteocalcin activity assays were assessed for cell differentiation. All treatment groups showed a significant increase in cell proliferation and differentiation compared to the control group. Regarding the exposure time, the subgroups treated with the LLLT for 6 min showed higher proliferation and differentiation rates for the powers delivered, the 300-mW LLLT group significantly increased the amount of cell proliferation. By contrast, the 100 and 200 mW groups showed significantly greater amounts of cell differentiation. These results suggest that the use of LLLT may play an important role in stimulating osteoblast cells for improved bone formation.

  15. Spatially selective Er/Yb-doped CaF2 crystal formation by CO2 laser exposure

    International Nuclear Information System (INIS)

    Kim, Dong-Seon; Lee, Jin-Ho; Lim, Ki-Soo

    2014-01-01

    Highlights: • Oxyfluoride glass–ceramics containing CaF 2 nanocrystals doped with Er 3+ and Yb 3+ ions were formed on the glass surface by CO 2 laser and a heat gun exposure. • Most of Er and Yb ions were distributed inside CaF 2 nanocrystals and fluorine loss was observed in the EDS element maps. • IR-to-VIS upconversion emission efficiency of laser annealed glass ceramics was much increased and compared with that of the furnace-annealed glass ceramics. • Distributed volume of the glass ceramics were estimated by a confocal fluorescence microscope imaging. - Abstract: We report the glass–ceramic precipitation on the oxyfluoride glass surface by spatially selective annealing with a CO 2 laser and a heat gun exposure. X-ray diffraction analysis showed the formation of major CaF 2 and miner Ca 2 SiO 4 nanoparticles. We observed ∼100 nm nanoparticle aggregation by tunneling electron microscopy and element distribution in glass and crystal phases. Spatial distribution of glass ceramics near the glass surface was probed by confocal fluorescence microscope by using much enhanced emission from the Er ions in the laser-treated area. Strong emissions at 365 nm excitation and visible up-conversion emissions at 980 nm excitation also indicated well incorporation of Er and Yb ions into a crystalline environment

  16. Spatially selective Er/Yb-doped CaF2 crystal formation by CO2 laser exposure

    International Nuclear Information System (INIS)

    Kim, Dong-Seon; Lee, Jin-Ho; Lim, Ki-Soo

    2015-01-01

    Highlights: • Oxyfluoride glass–ceramics containing CaF 2 nanocrystals doped with Er 3+ and Yb 3+ ions were formed on the glass surface by CO 2 laser and a heat gun exposure. • Most of Er and Yb ions were distributed inside CaF 2 nanocrystals and fluorine loss was observed in the EDS element maps. • IR-to-VIS upconversion emission efficiency of laser annealed glass ceramics was much increased and compared with that of the furnace-annealed glass ceramics. • Distributed volume of the glass ceramics were estimated by a confocal fluorescence microscope imaging. - Abstract: We report the glass–ceramic precipitation on the oxyfluoride glass surface by spatially selective annealing with a CO 2 laser and a heat gun exposure. X-ray diffraction analysis showed the formation of major CaF 2 and miner Ca 2 SiO 4 nanoparticles. We observed ∼100 nm nanoparticle aggregation by tunneling electron microscopy and element distribution in glass and crystal phases. Spatial distribution of glass ceramics near the glass surface was probed by confocal fluorescence microscope by using much enhanced emission from the Er ions in the laser-treated area. Strong emissions at 365 nm excitation and visible up-conversion emissions at 980 nm excitation also indicated well incorporation of Er and Yb ions into a crystalline environment

  17. Fabrication and stability of fiber bragg gratings for WDM applications using a 266 nm cw-laser

    DEFF Research Database (Denmark)

    Deyerl, Hans-Jürgen; Sørensen, Henrik Rokkjær; Jensen, Jesper Bo Damm

    2003-01-01

    Diode pumped continuous wave all solid state UV-lasers operating at 266 nm offer an interesting alternative to frequency doubled argon ion lasers. We compare photosensitivity, UV-writing of Bragg gratings and thermal decay at 244, 257 and 266 nm.......Diode pumped continuous wave all solid state UV-lasers operating at 266 nm offer an interesting alternative to frequency doubled argon ion lasers. We compare photosensitivity, UV-writing of Bragg gratings and thermal decay at 244, 257 and 266 nm....

  18. Compact, efficient diode-end-pumped Nd:GdVO4 slab continuous-wave 912-nm laser

    International Nuclear Information System (INIS)

    Liu Huan; Gong Ma-Li

    2012-01-01

    A fiber-coupled laser-diode (LD) end-pumped Nd:GdVO 4 slab continuous-wave (CW) 912-nm laser and an LD bar end-pumped Nd:GdVO 4 slab CW 912-nm laser are both demonstrated in this paper. Using the fiber-coupled LD of end-pumped type, a highest CW 912-nm laser output power of 10.17 W is obtained with a high optical-to-optical conversion efficiency of 24.6% and a slope efficiency of 34.5%. The measured M 2 factors of beam quality in x and y directions are 5.3 and 5.1, respectively. Besides, an LD bar of end-pumped type is used to realize CW 912-nm laser output, which has the advantages of compactness and low cost. When the pump power is 38.8 W, the output power is 8.87 W and the measured M 2 factors of beam quality in x and y directions are 16 and 1.31, respectively. In order to improve the beam quality of the 912-nm laser at x direction, a new quasi-concentric laser resonator will be designed, and an LD bar end-pumped Nd:GdVO 4 slab high-power CW 912-nm TEM 00 laser will be realized in the future. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  19. Enhancement of 800 nm upconversion emission in a thulium doped tellurite microstructured fiber pumped by a 1560 nm femtosecond fiber laser

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhixu; Zheng, Kezhi [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Yao, Chuanfei; Wang, Shunbin; Qin, Guanshi, E-mail: qings@jlu.edu.cn; Qin, Weiping, E-mail: wpqin@jlu.edu.cn [State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Xiong, Liangming; Luo, Jie; Lv, Dajuan [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); Ohishi, Yasutake [Research Center for Advanced Photon Technology, Toyota Technological Institute, 2-12-1 Hisakata, Tempaku, Nagoya 468–8511 (Japan)

    2016-04-28

    We report enhanced upconversion (UC) fluorescence in Tm{sup 3+} doped tellurite microstructured fibers (TDTMFs) fabricated by using a rod-in-tube method. Under the pumping of a 1560 nm femtosecond fiber laser, ultrabroadband supercontinuum light expanding from ∼1050 to ∼2700 nm was generated in a 4 cm long TDTMF. Simultaneously, intense 800 nm UC emission from the {sup 3}H{sub 4} → {sup 3}H{sub 6} transition of Tm{sup 3+} was observed in the same TDTMF. Compared to that pumped by a 1560 nm continuous wave fiber laser, the UC emission intensity was enhanced by ∼4.1 times. The enhancement was due to the spectral broadening in the TDTMF under the pumping of the 1560 nm femtosecond fiber laser.

  20. Resonantly diode-pumped continuous-wave and Q-switched Er:YAG laser at 1645 nm.

    Science.gov (United States)

    Chang, N W H; Simakov, N; Hosken, D J; Munch, J; Ottaway, D J; Veitch, P J

    2010-06-21

    We describe an efficient Er:YAG laser that is resonantly pumped using continuous-wave (CW) laser diodes at 1470 nm. For CW lasing, it emits 6.1 W at 1645 nm with a slope efficiency of 36%, the highest efficiency reported for an Er:YAG laser that is pumped in this manner. In Q-switched operation, the laser produces diffraction-limited pulses with an average power of 2.5 W at 2 kHz PRF. To our knowledge this is the first Q-switched Er:YAG laser resonantly pumped by CW laser diodes.

  1. Effect of 808 nm Diode Laser on Swimming Behavior, Food Vacuole Formation and Endogenous ATP Production of Paramecium primaurelia (Protozoa).

    Science.gov (United States)

    Amaroli, Andrea; Ravera, Silvia; Parker, Steven; Panfoli, Isabella; Benedicenti, Alberico; Benedicenti, Stefano

    2015-01-01

    Photobiomodulation (PBM) has been used in clinical practice for more than 40 years. To clarify the mechanisms of action of PBM at cellular and organism levels, we investigated its effect on Paramecium primaurelia (Protozoa) irradiated by an 808 nm infrared diode laser with a flat-top handpiece (1 W in CW). Our results led to the conclusion that: (1) the 808 nm laser stimulates the P. primaurelia without a thermal effect, (2) the laser effect is demonstrated by an increase in swimming speed and in food vacuole formation, (3) the laser treatment affects endogenous adenosine triphosphate (ATP) production in a positive way, (4) the effects of irradiation dose suggest an optimum exposure time of 50 s (64 J cm(-2) of fluence) to stimulate the Paramecium cells; irradiation of 25 s shows no effect or only mild effects and irradiation up to 100 s does not increase the effect observed with 50 s of treatment, (5) the increment of endogenous ATP concentration highlights the positive photobiomodulating effect of the 808 nm laser and the optimal irradiation conditions by the flat-top handpiece. © 2015 The American Society of Photobiology.

  2. Narrow line width operation of a 980 nm gain guided tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Barrientos-Barria, Jessica

    2011-01-01

    We demonstrate two different schemes for the spectral narrowing of a 12 emitter 980 nm gain guided tapered diode laser bar. In the first scheme, a reflective grating has been used in a Littman Metcalf configuration and the wavelength of the laser emission could be narrowed down from more than 5.......5 nm in the free running mode to 0.04 nm (FWHM) at an operating current of 30 A with an output power of 8 W. The spectrum was found to be tunable within a range of 16 nm. In the second scheme, a volume Bragg grating has been used to narrow the wavelength of the laser bar from over 5 nm to less than 0.......2 nm with an output of 5 W at 20 A. To our knowledge, this is the first time spectral narrowing has been performed on a gain guided tapered diode laser bar. In the Littman Metcalf configuration, the spectral brightness has been increased by 86 times and in the volume Bragg grating cavity the spectral...

  3. A diode-pumped Tm:CaYAlO4 laser at 1851 nm

    Science.gov (United States)

    Lan, Jinglong; Guan, Xiaofeng; Xu, Bin; Moncorgé, Richard; Xu, Huiying; Cai, Zhiping

    2017-07-01

    Laser emission at ~1850 nm is of great interest for neural stimulation applications. In this letter, we report on the diode-pumped continuous-wave (CW) and Q-switched (QS) laser operation of Tm:CaYAlO4 at 1851 nm, for the first time to our knowledge. In the CW regime, a maximum output power up to 0.62 W is obtained with a laser slope efficiency of about 18.0%. Using a Cr:ZnSe saturable absorber, QS laser operation is achieved with a maximum average output power of 0.25 W, the narrowest pulse width of 107 ns and the highest repetition rate of 5.85 kHz. The corresponding pulse peak power and pulse energy are about 388 W and 42.8 µJ, respectively. In this Q-switched mode, wavelength tuning is also realized over about 3 nm by slightly tilting the saturable absorber.

  4. Ablation from artificial or laser-induced crater surfaces of silver by laser irradiation at 355 nm

    DEFF Research Database (Denmark)

    Toftmann, B.; Schou, Jørgen; Larsen, N.B.

    1999-01-01

    The angular distribution of laser ablated particles from silver irradiated at 355 nm has been studied. The angular distribution from craters prepared by more than 10(4) shots exhibits only minor changes compared with that from a nonirradiated target. The distribution from artificial cylindrical c...... craters of a depth comparable to the laser spot dimensions is about one order of magnitude smaller at large exit angles than that from a flat target.......The angular distribution of laser ablated particles from silver irradiated at 355 nm has been studied. The angular distribution from craters prepared by more than 10(4) shots exhibits only minor changes compared with that from a nonirradiated target. The distribution from artificial cylindrical...

  5. Astigmatism-free high-brightness 1060 nm edge-emitting lasers with narrow circular beam profile.

    Science.gov (United States)

    Miah, Md Jarez; Kalosha, Vladimir P; Bimberg, Dieter; Pohl, Johannes; Weyers, Markus

    2016-12-26

    1060 nm high-brightness vertical broad-area edge-emitting lasers providing anastigmatic high optical power into a narrow circular beam profile are demonstrated. Ridge-waveguide (RW) lasers yield record 2.2 W single-transverse mode power in the 1060-nm wavelength range under continuous-wave (cw) operation at room temperature with excellent beam quality factor M2 ≤ 2. Independent of operating current the astigmatism is only 2.5 µm. 3 mm long broad-area (BA) lasers produce a θvert as narrow as 9° full width at half maximum, which agrees well with our simulation results, being insensitive to drive current. 5 mm long BA lasers deliver highest ever reported cw 12 W multimode output power among lasers showing θvert <10° in the 1060-nm wavelength range. The emitted laser beams from both RW and BA lasers show a perfect circular shape with ≤10° divergence angle at record 2.1 W and 4.2 W cw-mode output power, respectively.

  6. All-solid-state ultraviolet 330 nm laser from frequency-doubling of Nd:YLF red laser in CsB3O5

    International Nuclear Information System (INIS)

    Chen, Ming; Wang, Zhi-chao; Wang, Bao-shan; Yang, Feng; Zhang, Guo-chun; Zhang, Shen-jin; Zhang, Feng-feng; Zhang, Xiao-wen; Zong, Nan; Wang, Zhi-min; Bo, Yong; Peng, Qin-jun; Cui, Da-fu; Wu, Yi-cheng; Xu, Zu-yan

    2016-01-01

    We demonstrate an ultraviolet (UV) 330 nm laser from second-harmonic generation (SHG) of an all-solid-state Nd:YLF red laser in a CsB 3 O 5 (CBO) crystal for the first time, to our best knowledge. Under an input power of 4.8 W at 660 nm, a maximum average output power of 330 nm laser was obtained to be 1.28 W, corresponding to a frequency conversion efficiency of about 26.7%.

  7. Efficient room temperature cw Yb:glass laser pumped by a 946nm Nd:YAG laser

    OpenAIRE

    Koch, R.; Clarkson, W.A.; Hanna, D.C.; Jiang, S.; Myers, M.J.; Rhonehouse, D.; Hamlin, S.J.; Griebner, U.; Schönnagel, H.

    1997-01-01

    By pumping with a cw diode-pumped Nd:YAG laser operating at 946nm laser operation of a new Yb-doped phosphate glass with 440mW cw output power and a slope efficiency of 48% with respect to the absorbed pump power was achieved at room temperature

  8. Growth of Laser Initiated Damage in Fused Silica at 527 nm

    International Nuclear Information System (INIS)

    Norton, M A; Donohue, E E; Hollingsworth, W G; McElroy, J N; Hackel, R P

    2003-01-01

    The effective lifetime of optics is limited by both laser-induced damage and the subsequent growth of laser initiated damage sites. We have measured the growth rate of laser-induced damage in fused silica in both air and vacuum at 527 nm. For damage on the exit surface, the data shows exponential growth in the lateral size of the damage site with shot number. The exponential growth coefficient depends linearly on the laser fluence. The behavior at the fluence threshold for growth is contrasted to that observed at 351 nm. The growth rate was not significantly affected by either the wavelength of the initiating fluence or the presence of 10 torr of air as compared to vacuum. When the damage is located on the input surface, it has both a higher threshold for growth and does not grow exponentially

  9. A Faraday laser lasing on Rb 1529 nm transition.

    Science.gov (United States)

    Chang, Pengyuan; Peng, Huanfa; Zhang, Shengnan; Chen, Zhangyuan; Luo, Bin; Chen, Jingbiao; Guo, Hong

    2017-08-21

    We present the design and performance characterization of a Faraday laser directly lasing on the Rb 1529 nm transition (Rb, 5P 3/2  - 4D 5/2 ) with high stability, narrow spectral linewidth and low cost. This system does not need an additional frequency-stabilized pump laser as a prerequisite to preparing Rb atom from 5S to 5P excited state. Just by using a performance-improved electrodeless discharge lamp-based excited-state Faraday anomalous dispersion optical filter (LESFADOF), we realized a heterogeneously Faraday laser with the frequency corresponding to atomic transition, working stably over a range of laser diode (LD) current from 85 mA to 171 mA and the LD temperature from 11 °C to 32 °C, as well as the 24-hour long-term frequency fluctuation range of no more than 600 MHz. Both the laser linewidth and relative intensity noisy (RIN) are measured. The Faraday laser lasing on Rb 1529 nm transition (telecom C-band) can be applied to further research on metrology, microwave photonics and optical communication systems. Besides, since the transitions correspongding to the populated excited-states of alkali atoms within lamp are extraordinarily rich, this scheme can increase the flexibility for choosing proper wavelengths for Faraday laser and greatly expand the coverage of wavelength corresponding to atomic transmission for laser frequency stabilization.

  10. Investigation of single lateral mode for 852nm diode lasers with ridge waveguide design

    Science.gov (United States)

    Liu, Chu; Guan, Baolu; Mi, Guoxin; Liao, Yiru; Liu, Zhenyang; Li, Jianjun; Xu, Chen

    2016-11-01

    852nm Narrow linewidth lasers can be widely used in the field of ultra-fine spectrum measurement, Cs atomic clock control, satellite and optical fiber communication and so on. Furthermore, the stability of the single lateral mode is a very important condition to guarantee the narrow linewidth lasers. Here we investigate experimentally the influence of the narrow ridge structure and asymmetrical waveguide design on the stability single lateral mode of an 852nm diode laser. According to the waveguide theoretical analysis, ridge mesa etch depth (Δη , related to the refractive index difference of parallel to the junction) and ridge mesa width (the narrower the more control force to low order mode) are the main elements for lateral modes. In this paper, we designed different structures to investigate and verify major factors for lateral mode by experiment, and to confirm our thought. Finally, the 5μm mesa ridge laser, 800nm etch depth, with groove structure obtains excellent steady single lateral mode output by 150mA operating current and 30°C temperature. The optical spectrum FWHM is 0.5nm and side mode suppression ratio is 27dBm with uncoated. The laser with 1mm cavity length showed the threshold current of 50mA, a lasing wavelength of λ = 852.6nm, slope efficiency of above 0.7mW/mA. We accomplished single lateral mode of ridge waveguide edge-emitting lasers which can also be used as a laser source in the ultra-narrow linewidth external cavity laser system.

  11. Combined 595-nm and 1,064-nm laser irradiation of recalcitrant and hypertrophic port-wine stains in children and adults.

    Science.gov (United States)

    Alster, Tina S; Tanzi, Elizabeth L

    2009-06-01

    Although pulsed dye laser (PDL) treatment of port-wine stain (PWS) has long been proven safe and effective, incomplete clearance of these vascular malformations can be problematic. In addition, advanced PWS with deeper coloration and tissue hypertrophy can be particularly difficult to treat because of the superficial dermal penetration of 585- to 595-nm light. The purpose of this study was to evaluate the safety and efficacy of a novel device that delivers sequential pulses of 595- and 1,064-nm wavelengths in the treatment of recalcitrant and hypertrophic PWS. Twenty-five children and adults (skin phototypes I-III) with recalcitrant or hypertrophic PWS showing incomplete clearance after 10 prior PDL treatments were included in the study. Successive treatments using a 595-nm PDL and a 1,064-nm neodymium-doped yttrium-aluminum-garnet (Nd:YAG) laser were delivered at 6- to 8-week intervals. Two masked assessors determined clinical improvement of treatment areas using independent evaluation of comparative photographs at baseline and 3 months after treatment using a standard quartile grading scale. The use of dual 595-/1,064-nm wavelengths provided continued improvement of PWS that were previously recalcitrant to ongoing PDL therapy. Side effects were limited to transient erythema, edema, and mild purpura. Rare vesicle formation was observed, with no subsequent scarring or undesirable pigmentary changes. The novel dual 595-nm PDL and 1,064-nm Nd:YAG laser is an effective treatment for PWS that are recalcitrant to PDL therapy alone.

  12. A 1,470 nm diode laser in stapedotomy: Mechanical, thermal, and acoustic effects.

    Science.gov (United States)

    Koenraads, Simone P C; de Boorder, Tjeerd; Grolman, Wilko; Kamalski, Digna M A

    2017-08-01

    Multiple laser systems have been investigated for their use in stapes surgery in patients with otosclerosis. The diode 1,470 nm laser used in this study is an attractive laser system because it is easily transported and relatively inexpensive in use. This wavelength has relative high absorption in water. This study aimed to investigate the mechanical, thermal, and acoustic effects of the diode 1,470 nm laser on a stapes in an inner ear model. Experiments were performed in an inner ear model including fresh frozen human stapes. High-speed imaging with frame rates up to 2,000 frames per second (f/s) was used to visualize the effects in the vestibule during fenestration of the footplate. A special high-speed color Schlieren technique was used to study thermal effects. The sound produced by perforation was recorded by a hydrophone. Single pulse settings of the diode 1,470 nm laser were 100 ms, 3 W. Diode 1,470 nm laser fenestration showed mechanical effects with small vapor bubbles and pressure waves pushed into the vestibule. Thermal imaging visualized an increase temperature underneath the stapes footplate. Acoustic effects were limited, but larger sounds levels were reached when vaporization bubbles arise and explode in the vestibule. The diode 1,470 nm laser highly absorbs in perilymph and is capable of forming a clear fenestration in the stapes. An overlapping laser pulse will increase the risk of vapor bubbles, pressure waves, and heating the vestibule. As long as we do not know the possible damage of these effects to the inner ear function, it seems advisable to use the laser with less potential harm. Lasers Surg. Med. 49:619-624, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Diode-pumped CW frequency-doubled Nd:CNGG-BiBO blue laser at 468 nm

    International Nuclear Information System (INIS)

    Lü, Y F; Xia, J; Lin, J Q; Gao, X; Dong, Y; Xu, L J; Sun, G C; Zhao, Z M; Tan, Y; Chen, J F; Liu, Z X; Li, C L; Cai, H X; Liu, Z T; Ma, Z Y; Ning, G B

    2011-01-01

    Efficient and compact blue laser output at 468 nm is generated by intracavity frequency doubling of a continuous-wave (CW) diode-pumped Nd:CNGG laser at 935 nm. With 17.8 W of diode pump power and the frequency-doubling crystal BiB 3 O 6 (BiBO), a maximum output power of 490 mW in the blue spectral range at 468 nm has been achieved, corresponding to an optical-to-optical conversion efficiency of 2.8%; the output power stability over 4 h is better than 2.6%. To the best of our knowledge, this is first work on intracavity frequency doubling of a diode pumped Nd:CNGG laser at 935 nm

  14. Efficacy of diode laser (810 and 940 nm) for facial skin tightening.

    Science.gov (United States)

    Voravutinon, Nataya; Seawthaweesin, Kanikar; Bureethan, Apron; Srivipatana, Anchisa; Vejanurug, Patnapa

    2015-12-01

    Laser treatment has been introduced for facial skin tightening. However, no prior study has used a diode laser to treat facial skin laxity. To evaluate the efficacy and safety of a 810- and 940-nm diode laser (MeDioStarNeXT) for treating facial skin laxity. Thirty patients, with facial skin laxity grading scale II-IV, were enrolled in this study. Each patient underwent four sessions with a 810- and 940-nm diode laser (MeDioStarNeXT) treatment over 3-week intervals. Improvement in the laxity of facial skin was evaluated using a Cutometer MPA 580, spectrophotometer, and a grading scale. Significant improvement was observed with the Cutometer F3 and R7 parameters at 1 and 3 months after complete treatment, respectively. Physician assessment showed significant improvement in the laxity scale at 1 and 6 months after treatment. Approximately 10% of the patients reported mild pain or minor adverse events. Ninety-eight percent of the patients were satisfied with the treatments. Treatment with a diode laser (810 and 940 nm) is safe and may be effective for facial skin tightening. Maintenance treatment is necessary to sustain the effect of treatment. © 2015 Wiley Periodicals, Inc.

  15. Efficient 525 nm laser generation in single or double resonant cavity

    Science.gov (United States)

    Liu, Shilong; Han, Zhenhai; Liu, Shikai; Li, Yinhai; Zhou, Zhiyuan; Shi, Baosen

    2018-03-01

    This paper reports the results of a study into highly efficient sum frequency generation from 792 and 1556 nm wavelength light to 525 nm wavelength light using either a single or double resonant ring cavity based on a periodically poled potassium titanyl phosphate crystal (PPKTP). By optimizing the cavity's parameters, the maximum power achieved for the resultant 525 nm laser was 263 and 373 mW for the single and double resonant cavity, respectively. The corresponding quantum conversion efficiencies were 8 and 77% for converting 1556 nm photons to 525 nm photons with the single and double resonant cavity, respectively. The measured intra-cavity single pass conversion efficiency for both configurations was about 5%. The performances of the sum frequency generation in these two configurations was studied and compared in detail. This work will provide guidelines for optimizing the generation of sum frequency generated laser light for a variety of configurations. The high conversion efficiency achieved in this work will help pave the way for frequency up-conversion of non-classical quantum states, such as the squeezed vacuum and single photon states. The proposed green laser source will be used in our future experiments, which includes a plan to generate two-color entangled photon pairs and achieve the frequency down-conversion of single photons carrying orbital angular momentum.

  16. Generation of continuous-wave 194 nm laser for mercury ion optical frequency standard

    Science.gov (United States)

    Zou, Hongxin; Wu, Yue; Chen, Guozhu; Shen, Yong; Liu, Qu; Precision measurement; atomic clock Team

    2015-05-01

    194 nm continuous-wave (CW) laser is an essential part in mercury ion optical frequency standard. The continuous-wave tunable radiation sources in the deep ultraviolet (DUV) region of the spectrum is also serviceable in high-resolution spectroscopy with many atomic and molecular lines. We introduce a scheme to generate continuous-wave 194 nm radiation with SFM in a Beta Barium Borate (BBO) crystal here. The two source beams are at 718 nm and 266 nm, respectively. Due to the property of BBO, critical phase matching (CPM) is implemented. One bow-tie cavity is used to resonantly enhance the 718 nm beam while the 266 nm makes a single pass, which makes the configuration easy to implement. Considering the walk-off effect in CPM, the cavity mode is designed to be elliptical so that the conversion efficiency can be promoted. Since the 266 nm radiation is generated by a 532 nm laser through SHG in a BBO crystal with a large walk-off angle, the output mode is quite non-Gaussian. To improve mode matching, we shaped the 266 nm beam into Gaussian modes with a cylindrical lens and iris diaphragm. As a result, 2.05 mW 194 nm radiation can be generated. As we know, this is the highest power for 194 nm CW laser using SFM in BBO with just single resonance. The work is supported by the National Natural Science Foundation of China (Grant No. 91436103 and No. 11204374).

  17. Red laser-diode pumped 806 nm Tm3+: ZBLAN fibre laser

    Science.gov (United States)

    Juárez-Hernández, M.; Mejía, E. B.

    2017-06-01

    A Tm3+-doped fluorozirconate (ZBLAN) fibre laser operating CW at 806 nm when diode-pumped at 687 nm is described for the first time. This device is based on the 3F4  →  3H6 transition, and is suitable for first telecom window and sensing applications. A slope efficiency of 50.3% and low threshold pump-power of 11.6 mW were obtained. Maximum output power of 15 mW for 40 mW coupled pump was achieved.

  18. Formation of copper tin sulfide films by pulsed laser deposition at 248 and 355 nm

    DEFF Research Database (Denmark)

    Ettlinger, Rebecca Bolt; Crovetto, Andrea; Canulescu, Stela

    2016-01-01

    The influence of the laser wavelength on the deposition of copper tin sulfide (CTS) and SnS-rich CTS with a 248-nm KrF excimer laser (pulse length τ = 20 ns) and a 355-nm frequency-tripled Nd:YAG laser (τ = 6 ns) was investigated. A comparative study of the two UV wavelengths shows that the CTS...... film growth rate per pulse was three to four times lower with the 248-nm laser than the 355-nm laser. SnS-rich CTS is more efficiently ablated than pure CTS. Films deposited at high fluence have submicron and micrometer size droplets, and the size and area density of the droplets do not vary significantly...

  19. 650 nm Laser stimulated dating from Side Antique Theatre, Turkey

    International Nuclear Information System (INIS)

    Doğan, M.; Meriç, N.

    2014-01-01

    Samples were taken from the archeological excavation site, which was at the backs of the Side Antique Theatre. Samples were taken from under the base rock in this area. Polymineral fine grains were examined to determine the ages of the sediments. Samples gathered from the Side Antique Theatre were investigated through using the SAR method. Firstly, one part of the samples were evaluated by using conventional IRSL reading head model of (ELSEC-9010) which is infrared (880±80 nm) stimulation source with Schott BG39 filter. The IRSL age dating with feldspar minerals, gives a number of overestimated or underestimated age values as a result. A new reading head was proposed with the following configuration attachments for overestimation of equivalent dose rates. Measurements were done with this newly designed red laser stimulating reading head which works with Elsec 9010 OSL age dating system. SAR measurements were performed by (650±10 nm) red laser light source with two Schott BG3 filters. With usage of the new designed reading head; closer results were obtained in comparision with the Antique Theatre′s expected age range. Fading rates were taken into consideration and these corrections were also handled for true age results. - Highlights: • Polymineral fine grain feldspar minerals were used for dating. • Two different reading heads were used to determine equivalent doses. • IR stimulated (880 nm) and laser stimulated (650 nm) dating results were compared

  20. Negative-tone imaging with EUV exposure toward 13nm hp

    Science.gov (United States)

    Tsubaki, Hideaki; Nihashi, Wataru; Tsuchihashi, Toru; Yamamoto, Kei; Goto, Takahiro

    2016-03-01

    Negative-tone imaging (NTI) with EUV exposure has major advantages with respect to line-width roughness (LWR) and resolution due in part to polymer swelling and favorable dissolution mechanics. In NTI process, both resist and organic solvents play important roles in determining lithography performances. The present study describes novel chemically amplified resist materials based on NTI technology with EUV using a specific organic solvents. Lithographic performances of NTI process were described in this paper under exposures using ASML NXE:3300 EUV scanner at imec. It is emphasized that 14 nm hp was nicely resolved under exposure dose of 37 mJ/cm2 without any bridge and collapse, which are attributed to the low swelling character of NTI process. Although 13 nm hp resolution was potentially obtained, a pattern collapse still restricts its resolution in case coating resist film thickness is 40 nm. Dark mask limitation due mainly to mask defectivity issue makes NTI with EUV favorable approach for printing block mask to produce logic circuit. A good resolution of CD-X 21 nm/CD-Y 32 nm was obtained for block mask pattern using NTI with usable process window and dose of 49 mJ/cm2. Minimum resolution now reaches CD-X 17 nm / CD-Y 23 nm for the block. A 21 nm block mask resolution was not affected by exposure dose and explored toward low dose down to 18 mJ/cm2 by reducing quencher loading. In addition, there was a negligible amount of increase in LCDU for isolated dot pattern when decreasing exposure dose from 66 mJ/cm2 to 24 mJ/cm2. On the other hand, there appeared tradeoff relationship between LCDU and dose for dense dot pattern, indicating photon-shot noise restriction, but strong dependency on patterning features. Design to improve acid generation efficiency was described based on acid generation mechanism in traditional chemically amplified materials which contains photo-acid generator (PAG) and polymer. Conventional EUV absorber comprises of organic compounds is

  1. Role of diode lasers (800-980 nm) as adjuncts to scaling and root planing in the treatment of chronic periodontitis: a systematic review.

    Science.gov (United States)

    Qadri, Talat; Javed, Fawad; Johannsen, Gunnar; Gustafsson, Anders

    2015-11-01

    The purpose of this study was to systematically review currently available evidence regarding the role of diode lasers (810-980 nm) as adjuncts to scaling and root planing (SRP) in the treatment of chronic periodontitis (CP). Mechanical instrumentation of periodontal tissues followed by diode laser application leads to complete removal of pocket epithelium compared with conventional SRP. To address the focused question "Is SRP with adjunct diode lasers (810-980 nm) therapy more effective in the treatment of CP than when CP is treated by SRP alone?" databases were searched using the following key words: chronic periodontitis, diode laser, surgical, AND scaling and root planing, periodontal diseases, periodontal therapy, AND periodontal treatment. Original studies were included. Letters to the editor, case reports, commentaries, and reviews were excluded. Ten clinical studies were included. In all studies, patients were systemically healthy, and cigarette smokers were included in two studies. In five studies, SRP plus diode laser application was more effective in the treatment of CP than SRP, and three studies showed no difference. In two studies, there was a moderate reduction in periodontal inflammation using SRP plus diode laser. The diameter of optic fiber, laser wavelengths, power, pulse repetition rate, and duration of laser exposure ranged between 300 μm and 2 mm, 810-980 nm, 0.8-2.5 W, 10-60 Hz, and 10-100 ms, respectively. In CP patients with probing depths ≤5 mm, diode lasers, SRP plus diode laser (800-980 nm) is more effective in the treatment of CP than when SRP is used alone.

  2. Comparison of therapeutic effects between pulsed and continuous wave 810-nm wavelength laser irradiation for traumatic brain injury in mice.

    Directory of Open Access Journals (Sweden)

    Takahiro Ando

    Full Text Available Transcranial low-level laser therapy (LLLT using near-infrared light can efficiently penetrate through the scalp and skull and could allow non-invasive treatment for traumatic brain injury (TBI. In the present study, we compared the therapeutic effect using 810-nm wavelength laser light in continuous and pulsed wave modes in a mouse model of TBI.TBI was induced by a controlled cortical-impact device and 4-hours post-TBI 1-group received a sham treatment and 3-groups received a single exposure to transcranial LLLT, either continuous wave or pulsed at 10-Hz or 100-Hz with a 50% duty cycle. An 810-nm Ga-Al-As diode laser delivered a spot with diameter of 1-cm onto the injured head with a power density of 50-mW/cm(2 for 12-minutes giving a fluence of 36-J/cm(2. Neurological severity score (NSS and body weight were measured up to 4 weeks. Mice were sacrificed at 2, 15 and 28 days post-TBI and the lesion size was histologically analyzed. The quantity of ATP production in the brain tissue was determined immediately after laser irradiation. We examined the role of LLLT on the psychological state of the mice at 1 day and 4 weeks after TBI using tail suspension test and forced swim test.The 810-nm laser pulsed at 10-Hz was the most effective judged by improvement in NSS and body weight although the other laser regimens were also effective. The brain lesion volume of mice treated with 10-Hz pulsed-laser irradiation was significantly lower than control group at 15-days and 4-weeks post-TBI. Moreover, we found an antidepressant effect of LLLT at 4-weeks as shown by forced swim and tail suspension tests.The therapeutic effect of LLLT for TBI with an 810-nm laser was more effective at 10-Hz pulse frequency than at CW and 100-Hz. This finding may provide a new insight into biological mechanisms of LLLT.

  3. Frequency locking of compact laser-diode modules at 633 nm

    Science.gov (United States)

    Nölleke, Christian; Leisching, Patrick; Blume, Gunnar; Jedrzejczyk, Daniel; Pohl, Johannes; Feise, David; Sahm, Alexander; Paschke, Katrin

    2018-02-01

    This work reports on a compact diode-laser module emitting at 633 nm. The emission frequency can be tuned with temperature and current, while optical feedback of an internal DBR grating ensures single-mode operation. The laser diode is integrated into a micro-fabricated package, which includes optics for beam shaping, a miniaturized optical isolator, and a vapor cell as frequency reference. The achieved absolute frequency stability is below 10-8 , while the output power can be more than 10 mW. This compact absolute frequency-stabilized laser system can replace gas lasers and may be integrated in future quantum technology devices.

  4. The morphofunctional state of Purkin'e cells in the cerebellum of new-born rats following laser and gamma-ray exposure

    International Nuclear Information System (INIS)

    Zubkova, S.M.; Popov, V.I.

    1993-01-01

    Following of local laser (632.8 nm, 6.3. J/cm 2 ) and whole-body Gy gamma-ray exposures of new-born rats the contrast changes of morphometrical indices, RNA amount, and chromatophilia of Purkin'e cells in the cerebellum were seen. The preliminary laser exposure of new-born rat cerebellum artially increased activity of karyogene structures of the cerebellum cells which were inhibited by 6.37 Gy gamma-rays

  5. Treatment of dilated pores with 1410-nm fractional erbium-doped fiber laser.

    Science.gov (United States)

    Suh, Dong-Hye; Chang, Ka-Yeun; Lee, Sang-Jun; Song, Kye-Yong; Choi, Jeong Hwee; Shin, Min Kyung; Jeong, Ki-Heon

    2015-04-01

    Dilated pores can be an early sign of skin aging and are a significant cosmetic concern. The 1410-nm wavelength is optimal for superficial dermal treatments up to 650 μm deep. The aim of the present study was to evaluate the clinical effectiveness and safety of the fractional erbium-doped fiber 1410-nm laser in the treatment of dilated pores. Fifteen patients with dilated facial pores underwent three laser treatments at 3-week intervals. Posttreatment skin responses and side effects were assessed at treatment and follow-up visits by study physicians. Clinical effectiveness of treatment was assessed by both study physicians and patients 3 months after the final laser treatment using a quartile grading scale. Histological examination was performed using biopsy samples taken at baseline (pretreatment) and 3 months after the last treatment. This study showed that greater than 51 % improvement in dilated pores was demonstrated in 14 of 15 patients after three sessions of laser treatments. Improvements in skin texture, tone, and smoothness were reported in all patients. Treatment was well tolerated in all patients, with no unanticipated side effects. This study demonstrates that the 1410-nm fractional erbium fiber laser is effective and safe for treatment of dilated facial pores in Fitzpatrick skin types III-IV.

  6. Utilization of Nd-YAG (1064 nm) laser for female hair removal

    International Nuclear Information System (INIS)

    Ahmed, Ahlam Hassan

    2013-05-01

    The Cutera. Inc, cool Glide system laser is along pulsed Nd-YAG 1064 nm, of energy density 25 to 30 J/cm 2 and pulse duration 25 ms in all individual sessions.This study was held in Medical Arms Service Hospital. The period of study taken was three month. The study sample consisted of five patients base line photographs were taken before treatments and also after treatments. Photos show the satisfactory results of the laser treatment. In this study the hair removal treat went was conducted for female middle age group of 25-40 years. The Nd-YAG (1064 nm) laser was found to more effective in treatment of the hair removal, and complications can be minimized by using anesthesia and anti bio tics. The Nd-YAG laser therapy should be considered as a good and dependable alternative to other treatment radiation techniques. And effectiveness of treatment can be increased by using optimum power and duration.(Author)

  7. Laser ablation of ceramic Al2O3 at 193 nm and 248 nm: The importance of single-photon ionization processes

    Science.gov (United States)

    Peláez, R. J.; Afonso, C. N.; Bator, M.; Lippert, T.

    2013-06-01

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al2O3 in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to ≈2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al+ ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  8. New 445 nm blue laser for laryngeal surgery combines photoangiolytic and cutting properties.

    Science.gov (United States)

    Hess, Markus M; Fleischer, Susanne; Ernstberger, Marcel

    2018-06-01

    Photoangiolytic lasers have broadened the surgical armamentarium for many phonosurgical interventions. However, the pulse dye laser and potassium titanyl phosphate (KTP) laser have technical drawbacks and a smaller spectrum of indications. The new 445 nm wavelength laser, the so-called 'blue laser', proves to show tissue effects comparable to the KTP laser and is also capable of treating subepithelial vessels due to its photoangiolytic properties, it can coagulate and carbonize at higher energy levels, and can be used via glass fibers in non-contact and contact mode for in-office procedures. In contrast to the KTP, the new 445 nm laser can also be used as a cutting laser, thus combining very much wanted properties of diode or CO2 lasers with photoangiolytic lasers. Further advantages of the new laser are the; (1) portability of the shoe box sized, shock-proof laser machine for in-office and operating room usage, (2) the selection of pulse rates from continuous wave (cw) to less than a millisecond, (3) stronger tissue effects compared to KTP with similar energy and pulse settings, (4) far better cutting properties than the KTP, and thus (5) more possibilities for usage in laryngology as well as in other fields or surgery. We demonstrate the feasibility of the 445 nm laser in several laboratory experiments and show clinical cases where photoangiolysis and cutting was possible. However, this is a preliminary report and further systematic studies in greater numbers are warranted.

  9. Spatially selective Er/Yb-doped CaF{sub 2} crystal formation by CO{sub 2} laser exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-Seon; Lee, Jin-Ho; Lim, Ki-Soo, E-mail: kslim@chungbuk.ac.kr

    2014-10-30

    Highlights: • Oxyfluoride glass–ceramics containing CaF{sub 2} nanocrystals doped with Er{sup 3+} and Yb{sup 3+} ions were formed on the glass surface by CO{sub 2} laser and a heat gun exposure. • Most of Er and Yb ions were distributed inside CaF{sub 2} nanocrystals and fluorine loss was observed in the EDS element maps. • IR-to-VIS upconversion emission efficiency of laser annealed glass ceramics was much increased and compared with that of the furnace-annealed glass ceramics. • Distributed volume of the glass ceramics were estimated by a confocal fluorescence microscope imaging. - Abstract: We report the glass–ceramic precipitation on the oxyfluoride glass surface by spatially selective annealing with a CO{sub 2} laser and a heat gun exposure. X-ray diffraction analysis showed the formation of major CaF{sub 2} and miner Ca{sub 2}SiO{sub 4} nanoparticles. We observed ∼100 nm nanoparticle aggregation by tunneling electron microscopy and element distribution in glass and crystal phases. Spatial distribution of glass ceramics near the glass surface was probed by confocal fluorescence microscope by using much enhanced emission from the Er ions in the laser-treated area. Strong emissions at 365 nm excitation and visible up-conversion emissions at 980 nm excitation also indicated well incorporation of Er and Yb ions into a crystalline environment.

  10. Spatially selective Er/Yb-doped CaF{sub 2} crystal formation by CO{sub 2} laser exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-Seon; Lee, Jin-Ho; Lim, Ki-Soo, E-mail: kslim@chungbuk.ac.kr

    2015-04-15

    Highlights: • Oxyfluoride glass–ceramics containing CaF{sub 2} nanocrystals doped with Er{sup 3+} and Yb{sup 3+} ions were formed on the glass surface by CO{sub 2} laser and a heat gun exposure. • Most of Er and Yb ions were distributed inside CaF{sub 2} nanocrystals and fluorine loss was observed in the EDS element maps. • IR-to-VIS upconversion emission efficiency of laser annealed glass ceramics was much increased and compared with that of the furnace-annealed glass ceramics. • Distributed volume of the glass ceramics were estimated by a confocal fluorescence microscope imaging. - Abstract: We report the glass–ceramic precipitation on the oxyfluoride glass surface by spatially selective annealing with a CO{sub 2} laser and a heat gun exposure. X-ray diffraction analysis showed the formation of major CaF{sub 2} and miner Ca{sub 2}SiO{sub 4} nanoparticles. We observed ∼100 nm nanoparticle aggregation by tunneling electron microscopy and element distribution in glass and crystal phases. Spatial distribution of glass ceramics near the glass surface was probed by confocal fluorescence microscope by using much enhanced emission from the Er ions in the laser-treated area. Strong emissions at 365 nm excitation and visible up-conversion emissions at 980 nm excitation also indicated well incorporation of Er and Yb ions into a crystalline environment.

  11. Comparative analysis of the effect of the GaAlAs laser irradiation in 780 nm and 660 nm in the hypersensitive dentin

    International Nuclear Information System (INIS)

    Yuan, Sun Chien

    2003-01-01

    This study was to evaluate and compare the effects of the low intensity in laser radiation among GaAlAs 780 nm and GaAlAs 660 nm. The main proposal is to verify if there is any difference of the effects or results in low intensity laser application treatment of hypersensitive dentin, keeping the same parameters, only differing in wavelength. The samples were distributed in two groups. Group A 90 cases, treated with GaAlAs 780 nm and group B irradiated with GaAlAs 660 nm with a total of 76 cases analyzed. The results of application with GaAlAs 660 nm and GaAlAs 780 nm do not differ statistically. Which means using any one of the irradiation gives the same results. However can be noted that the response of reduction of hypersensitivity is faster with the radiation of GaAlAs 780 nm, but the results after three applications is the same for both types of radiation. (author)

  12. Laser ablation of nanoscale particles with 193 nm light

    International Nuclear Information System (INIS)

    Choi, J H; Lucas, D; Koshland, C P

    2007-01-01

    Laser interaction with nanoscale particles is distinct and different from laser-bulk material interaction, where a hot plasma is normally created. Here, we review our studies on 193 nm laser ablation of various nanoscale particles including NaCl, soot, polystyrene, and gold. The 20 ns laser beam with fluences up to 0.3 J/cm 2 irradiates nanoparticles in a gas stream at laser repetition rates from 10 to 100 Hz. The particle size distributions before and after irradiation are measured with a scanning mobility particle sizer (SMPS), and particle morphology is examined with electron microscopy. All the nanomaterials studied exhibit a similar disintegration pattern and similar particle formation characteristics. No broadband emission associated with particle heating or optical breakdown is observed. The nanoparticles formed after irradiation have a smaller mean diameter and an order of magnitude higher number concentration with a more spherical shape compared to the original particles. We use the photon-atom ratio (PAR) to interpret the laser-particle interaction energetics

  13. Laser Treatment of Professional Tattoos With a 1064/532-nm Dual-Wavelength Picosecond Laser.

    Science.gov (United States)

    Kauvar, Arielle N B; Keaney, Terrence C; Alster, Tina

    2017-12-01

    Picosecond-domain laser pulses improve the photomechanical disruption of tattoos. This study evaluates the efficacy and safety of a novel, dual-wavelength, 1,064/532-nm, picosecond-domain laser for tattoo clearance. This was a prospective, self-controlled, clinical study of 34 subjects with 39 tattoos treated at 2 sites with an interval of 4.8 ± 1.6 weeks and up to 10 treatments (mean, 7.5). Blinded evaluation and investigator assessment of serial digital images was performed to evaluate treatment efficacy in the 36 tattoos that received at least 3 treatments. Investigators also assessed efficacy before each treatment visit up to 10 treatments. Safety and tolerability was evaluated for all 39 tattoos that underwent at least 1 treatment. Blinded evaluation demonstrated that lightening of tattoos was achieved in all subjects, with 86% (31 of 36 tattoos) showing at least a 50% clearance after 3 treatments. Adverse events were few and transient in nature. Patient satisfaction and treatment tolerability were high. Treatment of single-colored and multicolored tattoos with this novel 1,064/532-nm picosecond laser is highly safe and effective.

  14. Design of a picosecond-laser-driven Ni-like Mo x-ray laser near 20 nm

    International Nuclear Information System (INIS)

    Nilsen, J.

    1997-01-01

    The gain is predicted for a solid molybdenum target illuminated by several joules of combined energy from a nanosecond laser pulse to create a preplasma followed by a picosecond laser pulse to drive the gain. Gains greater than 300cm -1 are predicted for the Ni-like Mo 4d 1 S 0 →4p 1 P 1 transition at 18.9 nm, which is driven by the monopole collisional excitation. High gain is also predicted for a self-photo-pumped 4f 1 P 1 →4d 1 P 1 transition at 22.0 nm and several other transitions driven by inner shell collisional ionization. copyright 1997 Optical Society of America

  15. Semiconductor lasers with a continuous tuning range above 100 nm in the nearest IR spectral region

    Energy Technology Data Exchange (ETDEWEB)

    Kostin, Yu O; Lobintsov, A A; Shramenko, M V [OOO ' Opton' , Moscow (Russian Federation); Ladugin, M A; Marmalyuk, A A [Open Joint-Stock Company M.F. Stel' makh Polyus Research Institute, Moscow (Russian Federation); Chamorovsky, A Yu [Superlum Ltd., Unit B3, Fota Point Enterprise Park, Carrigtwohill, Co Cork (Ireland); Yakubovich, S D [Moscow State Institute of Radio-Engineering, Electronics and Automation (Technical University), Moscow (Russian Federation)

    2015-08-31

    We have developed two new types of lasers based on quantum-confined semiconductor optical amplifiers with an acousto-optic tunable filter in an external fibre ring cavity. The lasers offer continuous wavelength tuning ranges from 780 to 885 and from 880 to 1010 nm, 20 mW of cw output power, and a tuning rate up to 10{sup 4} nm s{sup -1} at an instantaneous spectral linewidth less than 0.1 nm. (lasers)

  16. Defect engineering for 650 nm high-power AlGaInP laser diodes

    International Nuclear Information System (INIS)

    Kim, D.S.; Kim, K.C.; Shin, Y.C.; Kang, D.H.; Kim, B.J.; Kim, Y.M.; Park, Y.; Kim, T.G.

    2006-01-01

    To find the optimal growth and annealing conditions for high-power 650 nm band AlGaInP laser diodes, we carried out defect engineering, in which the distribution and density of deep level defects of the laser structure was analyzed. For this purpose, deep level transient spectroscopy (DLTS) measurements were carried out for each layer of the 650 nm band AlGaInP laser. By layer optimization at growth and annealing conditions, the laser diode was able operate stably and kink-free at high power over 220 mW at 70 deg. C. The characteristic temperatures (T ) were 212 K for 25-60 deg. C and 106 K over 60 deg. C

  17. 308-nm excimer laser for the treatment of alopecia areata in children.

    Science.gov (United States)

    Al-Mutairi, Nawaf

    2009-01-01

    Alopecia areata (AA) is a common skin disease which is characterized by nonscarring localized or diffused hair loss. In this study we assessed the efficacy of 308-nm Excimer laser in the treatment of alopecia areata in children. A total of 9 children with 30 recalcitrant patches alopecia areata and two children with alopecia areata totalis were enrolled in this study which included seven male and four female patients, aged between 4 and 14 years and the durations of their disease were between 7 and 25 months. All of these patients had more than one lesion of alopecia areata and at least one of them was left as a control for comparison. The lesions were treated with the 308-nm Excimer laser twice a week for a period of 12 weeks. Regrowth of hair was observed in 18 (60%) alopecia patches in the scalp, while there was no response in the control patches and over the extremities. Only four patients with scalp lesions showed a recurrence of alopecia after 6 months post laser therapy. So, 308-nm Excimer laser is considered an effective safe therapeutic option for patchy alopecia areata in children.

  18. Analysis of excimer laser radiant exposure effect toward corneal ablation volume at LASIK procedure

    Science.gov (United States)

    Adiati, Rima Fitria; Rini Rizki, Artha Bona; Kusumawardhani, Apriani; Setijono, Heru; Rahmadiansah, Andi

    2016-11-01

    LASIK (Laser Asissted In Situ Interlamelar Keratomilieusis) is a technique for correcting refractive disorders of the eye such as myopia and astigmatism using an excimer laser. This procedure use photoablation technique to decompose corneal tissues. Although preferred due to its efficiency, permanency, and accuracy, the inappropriate amount radiant exposure often cause side effects like under-over correction, irregular astigmatism and problems on surrounding tissues. In this study, the radiant exposure effect toward corneal ablation volume has been modelled through several processes. Data collecting results is laser data specifications with 193 nm wavelength, beam diameter of 0.065 - 0.65 cm, and fluence of 160 mJ/cm2. For the medical data, the myopia-astigmatism value, cornea size, corneal ablation thickness, and flap data are taken. The first modelling step is determining the laser diameter between 0.065 - 0.65 cm with 0.45 cm increment. The energy, power, and intensity of laser determined from laser beam area. Number of pulse and total energy is calculated before the radiant exposure of laser is obtained. Next is to determine the parameters influence the ablation volume. Regression method used to create the equation, and then the spot size is substituted to the model. The validation used is statistic correlation method to both experimental data and theory. By the model created, it is expected that any potential complications can be prevented during LASIK procedures. The recommendations can give the users clearer picture to determine the appropriate amount of radiant exposure with the corneal ablation volume necessary.

  19. Modeling of filamentation damage induced in silica by 351-nm laser pulses

    International Nuclear Information System (INIS)

    Milam, D.; Manes, K.R.; Williams, W.H.

    1996-01-01

    A major risk factor that must be considered in design of the National Ignition Facility is the possibility for catastrophic self-focusing of the 351-nm beam in the silica optical components that are in the final section of the laser. Proposed designs for the laser are analyzed by the beam-propagation code PROP92. A 351-nm self-focusing experiment, induction of tracking damage, was done to provide data for validation of this code. The measured self-focusing lengths were correctly predicted by the code

  20. Power and efficiency scaling of diode pumped Cr:LiSAF lasers: 770-1110 nm tuning range and frequency doubling to 387-463 nm.

    Science.gov (United States)

    Demirbas, Umit; Baali, Ilyes

    2015-10-15

    We report significant average power and efficiency scaling of diode-pumped Cr:LiSAF lasers in continuous-wave (cw), cw frequency-doubled, and mode-locked regimes. Four single-emitter broad-area laser diodes around 660 nm were used as the pump source, which provided a total pump power of 7.2 W. To minimize thermal effects, a 20 mm long Cr:LiSAF sample with a relatively low Cr-concentration (0.8%) was used as the gain medium. In cw laser experiments, 2.4 W of output power, a slope efficiency of 50%, and a tuning range covering the 770-1110 nm region were achieved. Intracavity frequency doubling with beta-barium borate (BBO) crystals generated up to 1160 mW of blue power and a record tuning range in the 387-463 nm region. When mode locked with a saturable absorber mirror, the laser produced 195 fs pulses with 580 mW of average power around 820 nm at a 100.3 MHz repetition rate. The optical-to-optical conversion efficiency of the system was 33% in cw, 16% in cw frequency-doubled, and 8% in cw mode-locked regimes.

  1. ArF excimer laser modulation of TNF-alpha and gelatinase B in NIH 3T3 cells; Modulation de l`expression du TNF-alpha et de la gelatinase B, apres irradiation de fibroblastes NIH 3T3 par un laser a excimeres a 193 NM

    Energy Technology Data Exchange (ETDEWEB)

    Naudy-Vives, C.; Courant, D.; Perot, J.C.; Garcia, J.; Fretier, P.; Court, L.; Dormont, D.

    1995-12-31

    The effects on TNF-alpha and gelatinase B activity in mammalian cells induced by 193 nm argon fluoride excimer laser have been investigated. The data show that a secretion of 92 kDa type IV collagenase and TNF-alpha were increased in cell culture supernatants. Moreover, the 193 nm laser radiation produces a decrease of cell proliferation and an increase of cell activation 8 hours after irradiation. The total protein amount increases with the delivered dose. Same, but less effects were obtained after exposure to a conventional UV lamp at 254 nm. (author). 8 refs.

  2. Damage threshold from large retinal spot size repetitive-pulse laser exposures.

    Science.gov (United States)

    Lund, Brian J; Lund, David J; Edsall, Peter R

    2014-10-01

    The retinal damage thresholds for large spot size, multiple-pulse exposures to a Q-switched, frequency doubled Nd:YAG laser (532 nm wavelength, 7 ns pulses) have been measured for 100 μm and 500 μm retinal irradiance diameters. The ED50, expressed as energy per pulse, varies only weakly with the number of pulses, n, for these extended spot sizes. The previously reported threshold for a multiple-pulse exposure for a 900 μm retinal spot size also shows the same weak dependence on the number of pulses. The multiple-pulse ED50 for an extended spot-size exposure does not follow the n dependence exhibited by small spot size exposures produced by a collimated beam. Curves derived by using probability-summation models provide a better fit to the data.

  3. Compact 2050 nm Semiconductor Diode Laser Master Oscillator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I effort seeks to develop DFB laser master oscillators at the novel wavelength of 12050 nm. Two prototypes will be built, tested, and delivered ....

  4. Safety and efficacy of 2,790-nm laser resurfacing for chest photoaging.

    Science.gov (United States)

    Grunebaum, Lisa D; Murdock, Jennifer; Cofnas, Paul; Kaufman, Joely

    2015-01-01

    Chest photodamage is a common cosmetic complaint. Laser treatment of the chest may be higher risk than other areas. The objective of this study was to assess the safety and efficacy of 2,790-nm chest resurfacing for photodamage. Twelve patients with Fitzpatrick skin types I-III were enrolled in this university IRB-approved study. Photo documentation was obtained at baseline and each visit. A test spot with the 2,790-nm resurfacing laser was performed on the chest. Patients who did not have adverse effects from the test spot went on to have a full chest resurfacing procedure. Patients were instructed on standardized aftercare, including sunscreen. A 5-point healing and photodamage improvement scale was used to rate improvement by both investigators and the patients and was obtained at 2 weeks, 1 month, 2 months, and 3 months. One pass chest treatment with the 2,790-nm resurfacing laser at fluences greater than or equal to 3.0 mJ with 10% overlap leads to unacceptable rates of hyperpigmentation. Double pass chest treatment at fluences less than or equal to 2.5 mJ with 10% overlap leads to mild improvement in chest photodamage parameters without significant or persistent adverse effects. Laser treatment of aging/photodamaged chest skin remains a challenge due to the delicacy of chest skin. Mild improvement may be obtained with double pass resurfacing with the 2,790-nm wavelength.

  5. Stimulation of DNA synthesis by 340nm/ 351nm UV laser irradiation

    International Nuclear Information System (INIS)

    Meldrum, R.A.; Wharton, C.W.

    1991-01-01

    During preliminary experiments designed to test the feasibility of using a 'caged' DNA break trapping agent, the authors observed a stimulation of incorporation of 3 H-thymidine into DNA when cells were irradiated with low doses (100-1000J/m 2 ) of 351nm UV laser irradiation. This wavelength is used to photolyse 'caged' dideoxynucleotides in our fast time course measurements of DNA repair in mammalian cells. The dose at which this stimulation was observed is well below that at which measurable damage is detected. (author)

  6. Cultured Human Fibroblast Biostimulation Using a 940 nm Diode Laser

    Science.gov (United States)

    Illescas-Montes, Rebeca; Melguizo-Rodríguez, Lucía; Manzano-Moreno, Francisco Javier; García-Martínez, Olga; Ruiz, Concepción

    2017-01-01

    Background: Fibroblasts are the main cells involved in regeneration during wound healing. The objective was to determine the effect of 940 nm diode laser on cultured human fibroblasts using different irradiation regimens. Methods: The CCD-1064Sk human epithelial fibroblast cell line was treated with a 940 nm diode laser at different energy doses (power: 0.2–1 W and energy density: 1–7 J/cm2) using different transmission modes (continuous or pulsed). The effect on cell growth at 24 and 72 h post-treatment was examined by measuring the proliferative capacity, the impact on the cell cycle, and the effect on cell differentiation. Results: fibroblast proliferative capacity was increased at 24 and 72 h post-treatment as a function of the energy dose. The greatest increase was observed with a power of 0.2 or 0.5 W and energy density between 1 and 4 J/cm2; no difference was observed between continuous and pulsed modes. There were no significant differences in cell cycle between treated groups and controls. α-actin expression was increased by treatment, indicating enhanced cell differentiation. Conclusion: The 940 nm diode laser has biostimulating effects on fibroblasts, stimulating proliferative capacity and cell differentiation without altering the cell cycle. Further researches are necessary to explore its potential clinical usefulness in wound healing. PMID:28773152

  7. Cultured Human Fibroblast Biostimulation Using a 940 nm Diode Laser

    Directory of Open Access Journals (Sweden)

    Rebeca Illescas-Montes

    2017-07-01

    Full Text Available Background: Fibroblasts are the main cells involved in regeneration during wound healing. The objective was to determine the effect of 940 nm diode laser on cultured human fibroblasts using different irradiation regimens. Methods: The CCD-1064Sk human epithelial fibroblast cell line was treated with a 940 nm diode laser at different energy doses (power: 0.2–1 W and energy density: 1–7 J/cm2 using different transmission modes (continuous or pulsed. The effect on cell growth at 24 and 72 h post-treatment was examined by measuring the proliferative capacity, the impact on the cell cycle, and the effect on cell differentiation. Results: fibroblast proliferative capacity was increased at 24 and 72 h post-treatment as a function of the energy dose. The greatest increase was observed with a power of 0.2 or 0.5 W and energy density between 1 and 4 J/cm2; no difference was observed between continuous and pulsed modes. There were no significant differences in cell cycle between treated groups and controls. α-actin expression was increased by treatment, indicating enhanced cell differentiation. Conclusion: The 940 nm diode laser has biostimulating effects on fibroblasts, stimulating proliferative capacity and cell differentiation without altering the cell cycle. Further researches are necessary to explore its potential clinical usefulness in wound healing.

  8. Laser ablation of UHMWPE-polyethylene by 438 nm high energy pulsed laser

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, L.; Gammino, S.; Mezzasalma, A.M.; Visco, A.M.; Badziak, J.; Parys, P.; Wolowski, J.; Woryna, E.; Krasa, J.; Laska, L.; Pfeifer, M.; Rohlena, K.; Boody, F.P

    2004-04-15

    Pulsed laser ablation of ultra-high-molecular-weight-polyethylene (UHMWPE) is investigated at Prague Asterix Laser System (PALS) Laboratory. The high ablation yield as a function of laser energy is presented at 438 nm laser wavelength. The mechanisms of the polymer ablation are studied on the base of ''in situ'' analysis, such as mass quadrupole spectrometry and time-of-flight measurements, and ''ex situ'' analysis, such as SEM investigations and Raman spectroscopy. Results show that the laser irradiation induces a strong polymer dehydrogenation and molecular emission due to different C{sub x}H{sub y} groups having high kinetic energy and high charge state. At a laser pulse energy of 150 J the H{sup +}, C{sup n+} ions (n=1 to 6) are emitted from the plasma with velocities of the order of 10{sup 8} cm/s, while the C{sub x}H{sub y} groups and the carbon clusters, detected up to C{sub 16}, have a velocity about one or two order magnitude lower. The laser ablation process produces a deep crater in the polymer, which depth depends on the laser pulse energy and it is of the order of 500 {mu}m. The crater volume increases with the laser pulse energy. Results demonstrated that the laser radiation modifies the polymer chains because dehydrogenated material and carbon-like structures are detected in the crater walls and in the bottom of the crater, respectively. A comparison of the experimental results with the data available in literature is presented and discussed.

  9. A 1,470 nm diode laser in stapedotomy : Mechanical, thermal, and acoustic effects

    NARCIS (Netherlands)

    Koenraads, Simone P.C.; de Boorder, Tjeerd; Grolman, Wilko; Kamalski, Digna M.A.

    2017-01-01

    Background and Objectives: Multiple laser systems have been investigated for their use in stapes surgery in patients with otosclerosis. The diode 1,470 nm laser used in this study is an attractive laser system because it is easily transported and relatively inexpensive in use. This wavelength has

  10. 970-nm ridge waveguide diode laser bars for high power DWBC systems

    Science.gov (United States)

    Wilkens, Martin; Erbert, Götz; Wenzel, Hans; Knigge, Andrea; Crump, Paul; Maaßdorf, Andre; Fricke, Jörg; Ressel, Peter; Strohmaier, Stephan; Schmidt, Berthold; Tränkle, Günther

    2018-02-01

    de lasers are key components in material processing laser systems. While mostly used as pump sources for solid state or fiber lasers, direct diode laser systems using dense wavelength multiplexing have come on the market in recent years. These systems are realized with broad area lasers typically, resulting in beam quality inferior to disk or fiber lasers. We will present recent results of highly efficient ridge waveguide (RW) lasers, developed for dense-wavelength-beamcombining (DWBC) laser systems expecting beam qualities comparable to solid state laser systems and higher power conversion efficiencies (PCE). The newly developed RW lasers are based on vertical structures with an extreme double asymmetric large optical cavity. Besides a low vertical divergence these structures are suitable for RW-lasers with (10 μm) broad ridges, emitting in a single mode with a good beam quality. The large stripe width enables a lateral divergence below 10° (95 % power content) and a high PCE by a comparably low series resistance. We present results of single emitters and small test arrays under different external feedback conditions. Single emitters can be tuned from 950 nm to 975 nm and reach 1 W optical power with more than 55 % PCE and a beam quality of M2 < 2 over the full wavelength range. The spectral width is below 30 pm FWHM. 5 emitter arrays were stabilized using the same setup. Up to now we reached 3 W optical power, limited by power supply, with 5 narrow spectral lines.

  11. New alternatives for laser vaporization of the prostate: experimental evaluation of a 980-, 1,318- and 1,470-nm diode laser device.

    Science.gov (United States)

    Wezel, Felix; Wendt-Nordahl, Gunnar; Huck, Nina; Bach, Thorsten; Weiss, Christel; Michel, Maurice Stephan; Häcker, Axel

    2010-04-01

    Several diode laser systems were introduced in recent years for the minimal-invasive surgical therapy of benign prostate enlargement. We investigated the ablation capacities, hemostatic properties and extend of tissue necrosis of different diode lasers at wavelengths of 980, 1,318 and 1,470 nm and compared the results to the 120 W GreenLight HPS laser. The laser devices were evaluated in an ex vivo model using isolated porcine kidneys. The weight difference of the porcine kidneys after 10 min of laser vaporization defined the amount of ablated tissue. Blood loss was measured in blood-perfused kidneys following laser vaporization. Histological examination was performed to assess the tissue effects. The side-firing 980 and 1,470 nm diode lasers displayed similar ablative capacities compared to the GreenLight HPS laser (n.s.). The 1,318-nm laser, equipped with a bare-ended fiber, reached a higher ablation rate compared to the other laser devices (each P laser with a bare-ended fiber reached the highest rate compared to the side-firing devices (each P diode lasers showed superior hemostatic properties compared to the GreenLight HPS laser (each P laser), respectively. The diode lasers offered similar ablative capacities and improved hemostatic properties compared to the 120 W GreenLight HPS laser in this experimental ex vivo setting. The higher tissue penetration of the diode lasers compared to the GreenLight HPS laser may explain improved hemostasis.

  12. Tunable high-power narrow-spectrum external-cavity diode laser based on tapered amplifier at 668 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Erbert, G.; Sumpf, B.

    2010-01-01

    A 668 nm tunable high-power narrow-spectrum diode laser system based on a tapered semiconductor optical amplifier in external cavity is demonstrated. The laser system is tunable from 659 to 675 nm. As high as 1.38 W output power is obtained at 668.35 nm. The emission spectral bandwidth is less than...

  13. 885-nm laser diode array pumped ceramic Nd:YAG master oscillator power amplifier system

    Science.gov (United States)

    Yu, Anthony W.; Li, Steven X.; Stephen, Mark A.; Seas, Antonios; Troupaki, Elisavet; Vasilyev, Aleksey; Conley, Heather; Filemyr, Tim; Kirchner, Cynthia; Rosanova, Alberto

    2010-04-01

    The objective of this effort is to develop more reliable, higher efficiency diode pumped Nd:YAG laser systems for space applications by leveraging technology investments from the DoD and other commercial industries. Our goal is to design, build, test and demonstrate the effectiveness of combining 885 nm laser pump diodes and the use of ceramic Nd:YAG for future flight missions. The significant reduction in thermal loading on the gain medium by the use of 885 nm pump lasers will improve system efficiency.

  14. Saturable absorber Q- and gain-switched all-Yb3+ all-fiber laser at 976 and 1064 nm.

    Science.gov (United States)

    Tsai, Tzong-Yow; Fang, Yen-Cheng; Huang, Huai-Min; Tsao, Hong-Xi; Lin, Shih-Ting

    2010-11-08

    We demonstrate a novel passively pulsed all-Yb3+ all-fiber laser pumped by a continuous-wave 915-nm pump laser diode. The laser was saturable absorber Q-switched at 976 nm and gain-switched at 1064 nm, using the method of mode-field-area mismatch. With a pump power of 
105 mW, the laser iteratively produced a 976-nm pulse with an energy of 2.8 μJ and a duration of 280 ns, followed by a 1064-nm pulse with 1.1 μJ and a 430-ns duration at a repetition rate of 9 kHz. A set of rate equations was established to simulate the self-balancing mechanism and the correlation between the Q- and gain-switched photon numbers and the populations of the gain and absorber fibers.

  15. High Harmonic Inverse Free-Electron-Laser Interaction at 800 NM

    CERN Document Server

    Sears, Chris M S; Colby, Eric R; Cowan, Benjamin; Plettner, Tomas; Siemann, Robert; Spencer, James

    2005-01-01

    The inverse Free Electron Laser (IFEL) interaction has recently been proposed and used as a short wavelength modulator forμbunching of beams for laser acceleration experiments*,**. These experiments utilized the fundamental of the interaction between the laser field and electron bunch. In the current experiment, we explore the higher order resonances of the IFEL interaction from a 3 period, 1.8 centimeter wavelength undulator with a picosecond, 0.25 mJ/pulse laser at 800 nm. The resonances are observed by adjusting the gap of the undulator while keeping the beam energy constant. We will also discuss diagnostics for obtaining beam overlap and statistical techniques used to account for machine drifts and analyze the data.

  16. Lead extraction by selective operation of a nanosecond-pulsed 355nm laser

    Science.gov (United States)

    Herzog, Amir; Bogdan, Stefan; Glikson, Michael; Ishaaya, Amiel A.; Love, Charles

    2016-03-01

    Lead extraction (LE) is necessary for patients who are suffering from a related infection, or in opening venous occlusions that prevent the insertion of additional lead. In severe cases of fibrous encapsulation of the lead within a vein, laser-based cardiac LE has become one of the foremost methods of removal. In cases where the laser radiation (typically at 308 nm wavelength) interacts with the vein wall rather than with the fibrotic lesion, severe injury and subsequent bleeding may occur. Selective tissue ablation was previously demonstrated by a laser operating in the UV regime; however, it requires the use of sensitizers (e.g.: tetracycline). In this study, we present a preliminary examination of efficacy and safety aspects in the use of a nanosecond-pulsed solid-state laser radiation, at 355 nm wavelength, guided in a catheter consisting of optical fibers, in LE. Specifically, we demonstrate a correlation between the tissue elasticity and the catheter advancement rate, in ex-vivo experiments. Our results indicate a selectivity property for specific parameters of the laser radiation and catheter design. The selectivity is attributed to differences in the mechanical properties of the fibrotic tissue and a normal vein wall, leading to a different photomechanical response of the tissue's extracellular matrix. Furthermore, we performed successful in-vivo animal trials, providing a basic proof of concept for using the suggested scheme in LE. Selective operation using a 355 nm laser may reduce the risk of blood vessel perforation as well as the incidence of major adverse events.

  17. Long Term Ultrastable Laser System at 780 nm for Atomic Clocks, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Gener8 and AOSense team together to propose a novel new architecture for a low-phase noise, single-frequency electronically tunable laser at 780 nm. This laser...

  18. Diode laser spectroscopy of oxygen electronic band at 760 nm

    International Nuclear Information System (INIS)

    Lucchesini, A.; De Rosa, M.; Gozzini, S.

    1998-01-01

    Collisional broadening and shift coefficients have been obtained by analyzing the line shapes of oxygen absorptions in the 760 nm electronic band. By using a diode laser spectrometer with commercially available etherostructure Al x Ga 1-x As diode lasers operating in 'free-running mode', line shape parameters have been collected at room temperature by varying the gas pressure. A systematic study has been carried on seven absorption lines by scanning the diode laser emission wavelength around the gas resonances. The weak absorption lines have been detected by using the wavelength modulation (WM) spectroscopy technique with second-harmonic detection

  19. Spectral narrowing of a 980 nm tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Lucas Leclin, Gaëlle

    2011-01-01

    High power diode laser bars are interesting in many applications such as solid state laser pumping, material processing, laser trapping, laser cooling and second harmonic generation. Often, the free running laser bars emit a broad spectrum of the order of several nanometres which limit their scope...... been "smile corrected" using individual phase masks for each emitter. The external cavity consists of the laser bar, both fast and slow axis micro collimators, smile correcting phase mask, 6.5x beam expanding lens combination, a 1200 lines/mm reflecting grating with 85% efficiency in the first order......, a slow axis focusing cylindrical lens of 40 mm focal length and an output coupler which is 10% reflective. In the free running mode, the laser emission spectrum was 5.5 nm wide at an operating current of 30A. The output power was measured to be in excess of 12W. Under the external cavity operation...

  20. Histologic evaluation of laser lipolysis comparing continuous wave vs pulsed lasers in an in vivo pig model.

    Science.gov (United States)

    Levi, Jessica R; Veerappan, Anna; Chen, Bo; Mirkov, Mirko; Sierra, Ray; Spiegel, Jeffrey H

    2011-01-01

    To evaluate acute and delayed laser effects of subdermal lipolysis and collagen deposition using an in vivo pig model and to compare histologic findings in fatty tissue after continuous wave diode (CW) vs pulsed laser treatment. Three CW lasers (980, 1370, and 1470 nm) and 3 pulsed lasers (1064, 1320, and 1440 nm) were used to treat 4 Göttingen minipigs. Following administration of Klein tumescent solution, a laser cannula was inserted at the top of a 10 × 2.5-cm rectangle and was passed subdermally to create separate laser "tunnels." Temperatures at the surface and at intervals of 4-mm to 20-mm depths were recorded immediately after exposure and were correlated with skin injury. Full-thickness cutaneous biopsy specimens were obtained at 1 day, 1 week, and 1 month after exposure and were stained with hematoxylin-eosin and trichrome stain. Qualitative and semiquantitative histopathologic evaluations were performed with attention to vascular damage, lipolysis, and collagen deposition. Skin surface damage occurred at temperatures exceeding 46°C. Histologic examination at 1 day after exposure showed hemorrhage, fibrous collagen fiber coagulation, and adipocyte damage. Adipocytes surrounded by histiocytes, a marker of lipolysis, were present at 1 week and 1 month after exposure. Collagen deposition in subdermal fatty tissue and in reticular dermis of some specimens was noted at 1 week and had increased at 1 month. Tissue treated with CW laser at 1470 nm demonstrated greater hemorrhage and more histiocytes at damage sites than tissue treated with pulsed laser at 1440 nm. There was a trend toward more collagen deposition with pulsed lasers than with CW lasers, but this was not statistically significant. Histopathologic comparison between results of CW laser at 980 nm vs pulsed laser at 1064 nm showed the same trend. Hemorrhage differences may result from pulse duration variations. A theoretical calculation estimating temperature rise in vessels supported this

  1. Over 19 W Single-Mode 1545 nm Er,Yb Codoped All-Fiber Laser

    Directory of Open Access Journals (Sweden)

    Jiadong Wu

    2017-01-01

    Full Text Available We report a high-power cladding-pumped Er,Yb codoped all-fiber laser with truly single transverse mode output. The fiber laser is designed to operate at 1545 nm by the use of a pair of fiber Bragg gratings (FBGs to lock and narrow the output spectrum, which can be very useful in generating the eye-safe ~1650 nm laser emission through the Stimulated Raman Scattering (SRS in silica fibers that is of interest in many applications. Two pieces of standard single-mode fibers are inserted into the laser cavity and output port to guarantee the truly single-mode output as well as good compatibility with other standard fiber components. We have obtained a maximum output power of 19.2 W at 1544.68 nm with a FWHM spectral width of 0.08 nm, corresponding to an average overall slope efficiency of 31.9% with respect to the launched pump power. This is, to the best of our knowledge, the highest output power reported from simple all-fiber single-mode Er,Yb codoped laser oscillator architecture.

  2. Lower Energy Endovenous Laser Ablation of the Great Saphenous Vein with 980 nm Diode Laser in Continuous Mode

    International Nuclear Information System (INIS)

    Kim, Hyun S.; Nwankwo, Ikechi J.; Hong, Kelvin; McElgunn, Patrick S.J.

    2006-01-01

    Purpose. To assess clinical outcomes, complication rates, and unit energy applied using 980 nm diode endovenous laser treatment at 11 watts for symptomatic great saphenous vein (GSV) incompetence and reflux disease. Methods. Thirty-four consecutive ablation therapies with a 980 nm diode endovenous laser at 11 watts were studied. The diagnosis of GSV incompetence with reflux was made by clinical evaluation and duplex Doppler examinations. The treated GSVs had a mean diameter of 1.19 cm (range 0.5-2.2 cm). The patients were followed with clinical evaluation and color flow duplex studies up to 18.5 months (mean 12.19 months ± 4.18). Results. Using 980 nm diode endovenous laser ablation in continuous mode, 100% technical success was noted. The mean length of GSVs treated was 33.82 cm (range 15-45 cm). The mean energy applied during the treatment was 1,155.81 joules (J) ± 239.50 (range 545.40-1620 J) for a mean treatment duration of 90.77 sec ± 21.77. The average laser fiber withdrawal speed was 0.35 cm/sec ± 0.054. The mean energy applied per length of GSV was 35.16 J/cm ± 8.43. Energy fluence, calculated separately for each patient, averaged 9.82 J/cm 2 ± 4.97. At up to 18.5 months follow-up (mean 12.19 months), 0% recanalization was noted; 92% clinical improvement was achieved. There was no major complication. Minor complications included 1 patient with hematoma at the percutaneous venotomy site, 1 patient with thrombophlebitis on superficial tributary varices of the treated GSV, 24% ecchymoses, and 32% self-limiting hypersensitivity/tenderness/'pulling' sensation along the treatment area. One patient developed temporary paresthesia. Four endovenous laser ablation treatments (12%) were followed by adjunctive sclerotherapies for improved cosmetic results. Conclusion. Endovenous laser ablation treatment of GSV using a 980 nm diode laser at 11 watts in continuous mode appears safe and effective. Mean energy applied per treated GSV length of 35.16 J/cm or mean

  3. Quasi-three-level thin-disk laser at 1024 nm based on diode-pumped Yb:YAG crystal

    International Nuclear Information System (INIS)

    Wang, A G; Li, Y L; Fu, X H

    2011-01-01

    We present for the first time, to the best of our knowledge, a Yb:YAG laser operating in a continuous wave (CW) on the quasi-three-level laser at 1024 nm, based on the 2 F 5/2 – 2 F 7/2 transition, generally used for a 1030 nm emission. The use of a pump module with 16 passes through the crystal allowed the realization of a Yb:YAG thin-disk laser with 370 mW of CW output power at 1024 nm. Moreover, intracavity second-harmonic generation (SHG) has also been achieved with a power of 45 mW at 512 nm by using a LiB 3 O 5 (LBO) nonlinear crystal

  4. Nerve fiber layer (NFL) degeneration associated with acute q-switched laser exposure in the nonhuman primate

    Science.gov (United States)

    Zwick, Harry; Zuclich, Joseph A.; Stuck, Bruce E.; Gagliano, Donald A.; Lund, David J.; Glickman, Randolph D.

    1995-01-01

    We have evaluated acute laser retinal exposure in non-human primates using a Rodenstock scanning laser ophthalmoscope (SLO) equipped with spectral imaging laser sources at 488, 514, 633, and 780 nm. Confocal spectral imaging at each laser wavelength allowed evaluation of the image plane from deep within the retinal vascular layer to the more superficial nerve fiber layer in the presence and absence of the short wavelength absorption of the macular pigment. SLO angiography included both fluorescein and indocyanine green procedures to assess the extent of damage to the sensory retina, the retinal pigment epithelium (RPE), and the choroidal vasculature. All laser exposures in this experiment were from a Q-switched Neodymium laser source at an exposure level sufficient to produce vitreous hemorrhage. Confocal imaging of the nerve fiber layer revealed discrete optic nerve sector defects between the lesion site and the macula (retrograde degeneration) as well as between the lesion site and the optic disk (Wallerian degeneration). In multiple hemorrhagic exposures, lesions placed progressively distant from the macula or overlapping the macula formed bridging scars visible at deep retinal levels. Angiography revealed blood flow disturbance at the retina as well as at the choroidal vascular level. These data suggest that acute parafoveal laser retinal injury can involve both direct full thickness damage to the sensory and non-sensory retina and remote nerve fiber degeneration. Such injury has serious functional implications for both central and peripheral visual function.

  5. High-power actively Q-switched single-mode 1342 nm Nd:YVO4 ring laser, injection-locked by a cw single-frequency microchip laser.

    Science.gov (United States)

    Koch, Peter; Bartschke, Juergen; L'huillier, Johannes A

    2015-11-30

    In this paper we report on the realization of a single-mode Q-switched Nd:YVO4 ring laser at 1342 nm. Unidirectional and single-mode operation of the ring laser is achieved by injection-locking with a continuous wave Nd:YVO4 microchip laser, emitting a single-frequency power of up to 40 mW. The ring laser provides a single-mode power of 13.9 W at 10 kHz pulse repetition frequency with a pulse duration of 18.2 ns and an excellent beam quality (M2 laser, a power of 8.7 W at 671 nm with a pulse duration of 14.8 ns and a beam propagation factor of M2 < 1.1 is obtained. The 671 nm radiation features a long-term spectral width of 75 MHz.

  6. Clinical Application of Diode Laser (980 nm) in Maxillofacial Surgical Procedures.

    Science.gov (United States)

    Aldelaimi, Tahrir N; Khalil, Afrah A

    2015-06-01

    For many procedures, lasers are now becoming the treatment of choice by both clinicians and patients, and in some cases, the standard of care. This clinical study was carried out at Department of Maxillofacial Surgery, Ramadi Teaching Hospital, Rashid Private Hospital and Razi Private Hospital, Anbar Health Directorate, Anbar Province, Iraq. A total of 32 patients including 22 (≈ 70%) male and 10 (≈ 30%) female with age range from 5 months to 34 years old. Chirolas 20 W diode laser emitting at 980 nm was used. Our preliminary clinical findings include sufficient hemostasis, coagulation properties, precise incision margin, lack of swelling, bleeding, pain, scar tissue formation and overall satisfaction were observed in the clinical application. The clinical application of the diode (980 nm) laser in maxillofacial surgery proved to be of beneficial effect for daily practice and considered practical, effective, easy to used, offers a safe, acceptable, and impressive alternative for conventional surgical techniques.

  7. High-Power 1180-nm GaInNAs DBR Laser Diodes

    DEFF Research Database (Denmark)

    Aho, Antti T.; Viheriala, Jukka; Korpijarvi, Ville-Markus

    2017-01-01

    We report high-power 1180-nm GaInNAs distributed Bragg reflector laser diodes with and without a tapered amplifying section. The untapered and tapered components reached room temperature output powers of 655 mW and 4.04 W, respectively. The diodes exhibited narrow linewidth emission with side...... and better carrier confinement compared with traditional GaInAs quantum wells. The development opens new opportunities for the power scaling of frequency-doubled lasers with emission at yellow-orange wavelengths....

  8. Continuous-wave and passively Q-switched Nd:YVO4 laser at 1085 nm

    Science.gov (United States)

    Lin, Hongyi; Liu, Hong; Huang, Xiaohua; Zhang, Jiyan

    2017-11-01

    An admirable and efficient Nd:YVO4 laser at 1085 nm is demonstrated with a compact 35 mm plano-plano cavity. A chosen narrow bandpass filter with high-transmittance (HT) coating at 1064 nm (T=96%) and optimized part-reflection (PR) coating at 1085 nm (T=15%) is used as the output coupler. In the continuous-wave (CW) regime, the maximum output power reaches 3110 mW at the pump power of 11.41 W. Based on a Cr:YAG crystal with initial-transmittance of 91%, the first passively Q-switched Nd:YVO4 laser at 1085 nm is achieved. When the pump power is changed from the threshold of 4.50 to 6.08 W, the dual-wavelength lines at 1064 and 1085 nm are generated simultaneously. However, at the pump power of above 6.08 W, the single-wavelength line at 1085 nm is achieved. The largest output power, the highest peak power, and the narrowest pulse width are 1615 mW, 878 W and 26.2 ns, respectively.

  9. Comparative in vitro study of tissue welding using a 808 nm diode laser and a Ho:YAG laser.

    Science.gov (United States)

    Ott, B; Züger, B J; Erni, D; Banic, A; Schaffner, T; Weber, H P; Frenz, M

    2001-01-01

    In vitro porcine arteries and veins have been welded end-to-end using either a 808 nm diode laser combined with an indocyanine green enhanced albumin solder, or with a continuous-wave (cw) Ho:YAG laser without biological solder. The vascular stumps were approached to each other over a coronary dilatation catheter in order to obtain a precise alignment and good coaptation. Standard histology revealed for both welding techniques lateral tissue damage between 2 and 3 mm caused by laser-induced heat. Good solder attachment to the tissue was observed by the use of a scanning electron microscope. The vessels soldered with the 808 nm diode laser using albumin solder showed considerably higher tensile strength (1 N compared to 0.3 N) than vessels welded exclusively by Ho:YAG laser radiation. In contrast, leaking pressure (350 +/- 200 mmHg) and bursting pressure (457 +/- 200 mmHg) were found to be independent of the welding technique used. This study demonstrates that fast (total welding time about 2-5 min), stable and tight microvascular anastomosis can be achieved with the use of a dye-enhanced albumin laser soldering technique and an ancillary coronary dilatation catheter.

  10. A Pilot Study of Skin Resurfacing Using the 2,790-nm Erbium:YSGG Laser System.

    Science.gov (United States)

    Rhie, Jong Won; Shim, Jeong Su; Choi, Won Seok

    2015-01-01

    The erbium:yttrium scandium gallium garnet (Er:YSGG) laser differs from other laser techniques by having a faster and higher cure rate. Since the Er:YSGG laser causes an appropriate proportion of ablation and coagulation, it has advantages over the conventional carbon dioxide (CO2) laser and the erbium-doped yttrium aluminum garnet (Er:YAG) laser, including heating tendencies and explosive vaporization. This research was conducted to explore the effects and safety of the Er:YSGG laser. Twenty patients participated in the pilot study of a resurfacing system using a 2,790-nm Er:YSGG laser. All patients received facial treatment by the 2,790-nm Er:YSGG laser system (Cutera) twice with a 4-week interval. Wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture were measured. Study subjects included 15 women and five men. Re-epithelization occurred in all subjects 3 to 4 days after treatment, and wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture within 6 months of treatment. The 2,790-nm YSGG laser technique had fewer complications and was effective in the improvement of scars, pores, wrinkles, and skin tone and color with one or two treatments. We expect this method to be effective for people with acne scars, pore scars, deep wrinkles, and uneven skin texture and color.

  11. A Pilot Study of Skin Resurfacing Using the 2,790-nm Erbium:YSGG Laser System

    Directory of Open Access Journals (Sweden)

    Jong Won Rhie

    2015-01-01

    Full Text Available BackgroundThe erbium:yttrium scandium gallium garnet (Er:YSGG laser differs from other laser techniques by having a faster and higher cure rate. Since the Er:YSGG laser causes an appropriate proportion of ablation and coagulation, it has advantages over the conventional carbon dioxide (CO2 laser and the erbium-doped yttrium aluminum garnet (Er:YAG laser, including heating tendencies and explosive vaporization. This research was conducted to explore the effects and safety of the Er:YSGG laser.MethodsTwenty patients participated in the pilot study of a resurfacing system using a 2,790-nm Er:YSGG laser. All patients received facial treatment by the 2,790-nm Er:YSGG laser system (Cutera twice with a 4-week interval. Wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture were measured.ResultsStudy subjects included 15 women and five men. Re-epithelization occurred in all subjects 3 to 4 days after treatment, and wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture within 6 months of treatment.ConclusionsThe 2,790-nm YSGG laser technique had fewer complications and was effective in the improvement of scars, pores, wrinkles, and skin tone and color with one or two treatments. We expect this method to be effective for people with acne scars, pore scars, deep wrinkles, and uneven skin texture and color.

  12. Low-cost 420nm blue laser diode for tissue cutting and hemostasis

    Science.gov (United States)

    Linden, Kurt J.

    2016-03-01

    This paper describes the use of a 420 nm blue laser diode for possible surgery and hemostasis. The optical absorption of blood-containing tissue is strongly determined by the absorption characteristics of blood. Blood is primarily comprised of plasma (yellowish extracellular fluid that is approximately 95% water by volume) and formed elements: red blood cells (RBCs), white blood cells (WBCs) and platelets. The RBCs (hemoglobin) are the most numerous, and due to the spectral absorption characteristics of hemoglobin, the optical absorption of blood has a strong relative maximum value in the 420 nm blue region of the optical spectrum. Small, low-cost laser diodes emitting at 420 nm with tens of watts of continuous wave (CW) optical power are becoming commercially available. Experiments on the use of such laser diodes for tissue cutting with simultaneous hemostasis were carried out and are here described. It was found that 1 mm deep x 1 mm wide cuts can be achieved in red meat at a focused laser power level of 3 W moving at a velocity of ~ 1 mm/s. The peripheral necrosis and thermal damage zone extended over a width of approximately 0.5 mm adjacent to the cuts. Preliminary hemostasis experiments were carried out with fresh equine blood in Tygon tubing, where it was demonstrated that cauterization can occur in regions of intentional partial tubing puncture.

  13. Laser induced transient absorptions of the excited triplet state of 9,10-anthraquinone-2-sulfonate. A further study by 248 nm laser photolysis

    International Nuclear Information System (INIS)

    Ma Jianhua; Lin Weizheng; Wang Wenfen; Yao Side; Lin Nianyun

    1999-01-01

    Transient absorption spectrum of triplet state of 9,10-anthraquinone-2-sulfonate (AQS) in aqueous solution has been investigated using 248 nm (KrF) laser photolysis. A whole transient absorption spectrum with absorption maxim at 380 nm and 580 nm has been assigned to triple AQS from detailed kinetic analysis of decay of 380 nm and 580 nm signals, which is the neat characteristic absorption of triplet AQS reported for the first time. In addition, the difference in feature of the spectrum of triplet AQS in H 2 O and that in CH 3 CN was eliminated by further study using 248 nm laser pulses

  14. Design of a solar-pumped frequency-doubled 532 nm Nd:YVO4 laser

    Science.gov (United States)

    Kittiboonanan, P.; Putchana, W.; Deeudomand, M.; Ratanavis, A.

    2017-09-01

    During the last year we have made progresson a development of a frequency-doubled 532 nm Nd:YVO4 laser pumped by solar light. The research aimed to demonstrate solar pumped lasers consisting of the optically contracted Nd:YVO4 crystal and KTP crystal with a system of laser mirrors deposited onto crystal sides. The Cassegrain reflector is used as the configuration. This solar pumped laser system is appealing for a variety applications including laser communication, imaging and defense applications.

  15. End-pumped continuous-wave intracavity yellow Raman laser at 590 nm with SrWO4 Raman crystal

    Science.gov (United States)

    Yang, F. G.; You, Z. Y.; Zhu, Z. J.; Wang, Y.; Li, J. F.; Tu, C. Y.

    2010-01-01

    We present an end-pumped continuous-wave intra-cavity yellow Raman laser at 590 nm with a 60 mm long pure crystal SrWO4 and an intra-cavity LiB3O5 frequency doubling crystal. The highest output power of yellow laser at 590 nm was 230 mW and the output power and threshold were found to be correlative with the polarized directions of pure single crystal SrWO4 deeply. Along different directions, the minimum and maximum thresholds of yellow Raman laser at 590 nm were measured to be 2.8 W and 14.3 W with respect to 808 nm LD pump power, respectively.

  16. End-pumped continuous-wave intracavity yellow Raman laser at 590 nm with SrWO4 Raman crystal

    International Nuclear Information System (INIS)

    Yang, F G; You, Z Y; Zhu, Z J; Wang, Y; Li, J F; Tu, C Y

    2010-01-01

    We present an end-pumped continuous-wave intra-cavity yellow Raman laser at 590 nm with a 60 mm long pure crystal SrWO 4 and an intra-cavity LiB 3 O 5 frequency doubling crystal. The highest output power of yellow laser at 590 nm was 230 mW and the output power and threshold were found to be correlative with the polarized directions of pure single crystal SrWO 4 deeply. Along different directions, the minimum and maximum thresholds of yellow Raman laser at 590 nm were measured to be 2.8 W and 14.3 W with respect to 808 nm LD pump power, respectively

  17. 532 nm KTP激光治疗鲜红斑痣的自身对照研究%Efficacy and safety of 532 nm KTP laser in the treatment of port-wine stains

    Institute of Scientific and Technical Information of China (English)

    杨千里; 郑文渊; 卢忠

    2017-01-01

    Objective: To compare the efficacy and adverse reactions of 532 nm KTP laser and 595 nm pulsed dye laser in the treatment of port wine stain. Methods:The lesions of 18 patients were divided into two areas. One area was treated with 532 nm KTP laser and another area was treated with 595 nm pulsed dye la ̄ser, once every 2~3 months for 2~4 times. The safety and efficacy were evaluated after the treatment and in 2-3 months after the treatment. Results:There was no significant difference in the cure rate between 532 nm KTP laser and 595 nm pulsed dye laser. Some patients who were resistant to pulsed dye laser treatment were also sensitive to the treatment with 532 nm KTP laser. There were less pain and less purpura in the group of 532 nm KTP laser. Only one patient in each group developed hyperpigmentation. Conclusion: 532 nm KTP laser has similar efficacy to 595 nm pulsed dye laser and relatively less adverse reactions. It can be used as an alternative treatment of port wine stain.%目的::比较532 nm KTP激光与脉冲染料激光( PDL)对鲜红斑痣的疗效及安全性。方法:将18例鲜红斑痣患者的自身皮损随机分成KTP激光治疗区及PDL治疗区,分别予以532 nm KTP激光及595 nm PDL治疗,每2~3个月治疗一次,共2~4次。每次治疗前、后即刻及治疗后2~3个月对患者激光治疗后的皮损进行疗效及安全性评价。结果:532 nm KTP激光治疗组及595 nm PDL治疗组治疗后疗效均无显著差异。在一些既往曾接受PDL治疗疗效不佳的患者,经532 nm KTP 激光治疗后,皮损取得一定改善。532 nm KTP激光治疗组在治疗时疼痛程度及治疗后紫癜程度均显著低于595 nmPDL治疗组。两组均有1例色素沉着发生。结论:532 nm KTP激光治疗鲜红斑痣的疗效较好,不良反应少,安全性好,可以作为鲜红斑痣治疗的另一方案。

  18. Comparative Study of the Detection of Chromium Content in Rice Leaves by 532 nm and 1064 nm Laser-Induced Breakdown Spectroscopy

    Directory of Open Access Journals (Sweden)

    Jiyu Peng

    2018-02-01

    Full Text Available Fast detection of toxic metals in crops is important for monitoring pollution and ensuring food safety. In this study, laser-induced breakdown spectroscopy (LIBS was used to detect the chromium content in rice leaves. We investigated the influence of laser wavelength (532 nm and 1064 nm excitation, along with the variations of delay time, pulse energy, and lens-to-sample distance (LTSD, on the signal (sensitivity and stability and plasma features (temperature and electron density. With the optimized experimental parameters, univariate analysis was used for quantifying the chromium content, and several preprocessing methods (including background normalization, area normalization, multiplicative scatter correction (MSC transformation and standardized normal variate (SNV transformation were used to further improve the analytical performance. The results indicated that 532 nm excitation showed better sensitivity than 1064 nm excitation, with a detection limit around two times lower. However, the prediction accuracy for both excitation wavelengths was similar. The best result, with a correlation coefficient of 0.9849, root-mean-square error of 3.89 mg/kg and detection limit of 2.72 mg/kg, was obtained using the SNV transformed signal (Cr I 425.43 nm induced by 532 nm excitation. The results indicate the inspiring capability of LIBS for toxic metals detection in plant materials.

  19. Continuous-wave laser at 440 nm based on frequency-doubled diode-pumped Nd:GdVO(4) crystal.

    Science.gov (United States)

    Castaing, Marc; Balembois, François; Georges, Patrick

    2008-09-01

    We present for the first time, to the best of our knowledge, a frequency-doubled Nd:GdVO(4) laser operating in a cw on the pure three-level laser line at 880 nm. We obtained 300 mW at 440 nm for 23 W of incident pump power at 808 nm. Moreover, with a 25% output coupler we obtained a cw power of 1.9 W at the fundamental wavelength at 880 nm.

  20. Wavelength beam combining of a 980-nm tapered diode laser bar in an external cavity

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2010-01-01

    solution for preserving the beam quality of the bar in the range of that of a single emitter and at the same time, enabling the power scaling. We report spectral beam combining applied to a 12 emitter tapered laser bar at 980 nm. The external cavity has been designed for a wavelength separation of 4.0 nm......High power diode lasers are used in a large number of applications. A limiting factor for more widespread use of broad area lasers is the poor beam quality. Gain guided tapered diode lasers are ideal candidates for industrial applications that demands watt level output power with good beam quality...

  1. Laser ablation of ceramic Al{sub 2}O{sub 3} at 193 nm and 248 nm: The importance of single-photon ionization processes

    Energy Technology Data Exchange (ETDEWEB)

    Pelaez, R. J.; Afonso, C. N. [Laser Processing Group, Instituto de Optica, CSIC, Serrano 121, Madrid 28006 (Spain); Bator, M.; Lippert, T. [General Energy Research Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2013-06-14

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al{sub 2}O{sub 3} in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to Almost-Equal-To 2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al{sup +} ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  2. A InGaN/GaN quantum dot green (λ=524 nm) laser

    KAUST Repository

    Zhang, Meng

    2011-01-01

    The characteristics of self-organized InGaN/GaN quantum dot lasers are reported. The laser heterostructures were grown on c-plane GaN substrates by plasma-assisted molecular beam epitaxy and the laser facets were formed by focused ion beam etching with gallium. Emission above threshold is characterized by a peak at 524 nm (green) and linewidth of 0.7 nm. The lowest measured threshold current density is 1.2 kA/ cm2 at 278 K. The slope and wall plug efficiencies are 0.74 W/A and ∼1.1%, respectively, at 1.3 kA/ cm 2. The value of T0 =233 K in the temperature range of 260-300 K. © 2011 American Institute of Physics.

  3. In situ growth monitoring of AlGaN/GaN distributed Bragg reflectors at 530 nm using a 633 nm laser

    Energy Technology Data Exchange (ETDEWEB)

    Wen Feng; Huang Lirong; Jiang Bo; Tong Liangzhu; Xu Wei; Liu Deming, E-mail: hlr5649@163.co [Wuhan National Laboratory for Optoelectronics, College of Opto-Electronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2010-09-15

    The metal-organic chemical vapor deposition (MOCVD) growth of AlGaN/GaN distributed Bragg reflectors (DBR) with a reflection peak at 530 nm was in situ monitored using 633 nm laser reflectometry. Evolutions of in situ reflected reflectivity for different kinds of AlGaN/GaN DBR were simulated by the classical transfer matrix method. Two DBR samples, which have the same parameters as the simulated structures, were grown by MOCVD. The simulated and experimental results show that it is possible to evaluate the DBR parameters from the envelope shape of the in situ reflectivity spectrum. With the help of the 633 nm laser reflectometry, a DBR light emitting diode (LED) was grown. The room temperature photoluminescence spectra show that the reflection peak of the DBR in the LED is within the design region. (semiconductor devices)

  4. XUV-laser spectroscopy of HD at 92-98 nm.

    NARCIS (Netherlands)

    Hinnen, P.C.; Werners, S.E.; Stolte, S.; Hogervorst, W.; Ubachs, W.M.G.

    1995-01-01

    Sub-Doppler excitation spectra of HD have been recorded in the range 9298 nm with the use of a narrow-band and tunable extreme ultraviolet laser in combination with a molecular beam. Frequencies of 147 transitions to the B 1u+, C 1 u, and EF 1g+ states have been calibrated with an average absolute

  5. Tuning range and output power optimization of an external-cavity GaN diode laser at 455 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2016-01-01

    In this paper we discuss how different feedback gratings affect the tuning range and the output power of external feedback diode laser systems. A tunable high-power narrow-spectrum external-cavity diode laser system around 455 nm is investigated. The laser system is based on a high-power GaN diode...... laser in a Littrow external-cavity. Both a holographic diffraction grating and a ruled diffraction grating are used as feedback elements in the external cavity. The output power, spectral bandwidth, and tunable range of the external cavity diode laser system are measured and compared with the two...... gratings at different injected currents. When the holographic grating is used, the laser system can be tuned over a range of 1.4 nm with an output power around 530 mW. When the ruled grating is used, the laser system can be tuned over a range of 6.0 nm with an output power around 80 mW. The results can...

  6. Corneal tissue interactions of a new 345 nm ultraviolet femtosecond laser.

    Science.gov (United States)

    Hammer, Christian M; Petsch, Corinna; Klenke, Jörg; Skerl, Katrin; Paulsen, Friedrich; Kruse, Friedrich E; Seiler, Theo; Menzel-Severing, Johannes

    2015-06-01

    To assess the suitability of a new 345 nm ultraviolet (UV) femtosecond laser for refractive surgery. Department of Ophthalmology, University of Erlangen-Nürnberg, Erlangen, Germany. Experimental study. Twenty-five porcine corneas were used for stromal flap or lamellar bed creation (stromal depth, 150 μm) and 15 rabbit corneas for lamellar bed creation near the endothelium. Ultraviolet femtosecond laser cutting-line morphology, gas formation, and keratocyte death rate were evaluated using light and electron microscopy and compared with a standard infrared (IR) femtosecond laser. Endothelial cell survival was examined after application of a laser cut near the endothelium. Flaps created by the UV laser were lifted easily. Gas formation was reduced 4.2-fold compared with the IR laser (P = .001). The keratocyte death rate near the interface was almost doubled; however, the death zone was confined to a region within 38 μm ± 10 (SD) along the cutting line. Histologically and ultrastructurally, a distinct and continuous cutting line was not found after UV femtosecond laser application if flap lifting was omitted and standard energy parameters were used. Instead, a regular pattern of vertical striations, presumably representing self-focusing induced regions of optical tissue breakdown, were identified. Lamellar bed creation with standard energy parameters 50 μm from the endothelium rendered the endothelial cells intact and viable. The new 345 nm femtosecond laser is a candidate for pending in vivo trials and future high-precision flap creation, intrastromal lenticule extraction, and ultrathin Descemet-stripping endothelial keratoplasty. Mr. Klenke and Ms. Skerl were paid employees of Wavelight GmbH when the study was performed. Dr. Seiler is a scientific consultant to Wavelight GmbH. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Polishing Sapphire Substrates by 355 nm Ultraviolet Laser

    Directory of Open Access Journals (Sweden)

    X. Wei

    2012-01-01

    Full Text Available This paper tries to investigate a novel polishing technology with high efficiency and nice surface quality for sapphire crystal that has high hardness, wear resistance, and chemical stability. A Q-switched 355 nm ultraviolet laser with nanosecond pulses was set up and used to polish sapphire substrate in different conditions in this paper. Surface roughness Ra of polished sapphire was measured with surface profiler, and the surface topography was observed with scanning electronic microscope. The effects of processing parameters as laser energy, pulse repetition rate, scanning speed, incident angle, scanning patterns, and initial surface conditions on surface roughness were analyzed.

  8. 808-nm diode-pumped continuous-wave Tm:GdVO4 laser at room temperature

    Science.gov (United States)

    Urata, Yoshiharu; Wada, Satoshi

    2005-05-01

    A high-quality gadolinium vanadate (GdVO4) crystal with 7-at. % thulium as the starting material was grown by the Czochralski technique. The measured absorption spectra exhibited sufficient absorption coefficients for laser diodes (LDs) for neodymium laser pumping: 6.0 cm^-1 for pi polarization and 6.2 cm^-1 for sigma polarization at 808 nm. Laser oscillation was carried out with single-stripe 808-nm LDs in an end-pumping configuration. A slope efficiency of 28% and a threshold of 750 mW were exhibited with respect to the absorbed pump power. An output power of 420 mW was achieved at an absorbed power of 2.4 W. It was demonstrated that Tm:GdVO4 is a useful material for 2-μm lasers, particularly in a compact LD-pumped system.

  9. Fast and stable gratings inscription in POFs made of different materials with pulsed 248 nm KrF laser

    DEFF Research Database (Denmark)

    Marques, C. A.F.; Min, R.; Leal, A.

    2018-01-01

    This paper presents fiber Bragg grating (FBG) inscription with a pulsed 248 nm UV KrF laser in polymer optical fibers (POFs) made of different polymers, namely polymethyl methacrylate (PMMA), cyclic-olefin polymer and co-polymer, and Polycarbonate. The inscribed gratings and the corresponding...... inscription parameters are compared with grating inscribed in POFs made of the aforementioned materials but with the hitherto most used laser for inscription, which is a continuous wave 325 nm UV HeCd laser. Results show a reduction of the inscription time of at least 16 times. The maximum time reduction...... is more than 130 times. In addition, a reflectivity and a bandwidth close to or higher than the ones with the 325 nm laser were obtained. The polymer optical fiber Bragg gratings (POFBGs) inscribed with the 248 nm laser setup present high stability with small variations in their central wavelength...

  10. 1950-nm diode laser-assisted microanastomoses (LAMA): an innovative surgical tool for hand surgery emergencies.

    Science.gov (United States)

    Leclère, Franck Marie; Schoofs, Michel; Vogt, Peter; Casoli, Vincent; Mordon, Serge

    2015-05-01

    Based on previous observations, the 1950-nm diode laser seems to be an ideal wavelength for laser microvascular anastomoses. The data presented here, part of a larger ongoing study, assess its use in emergency hand surgery. Between 2011 and 2014, 11 patients were operated on for hand trauma with laser-assisted microanastomoses (LAMA) and prospectively analysed. LAMA was performed with a 1950-nm diode laser after placement of equidistant stitches. For vessel size laser parameters were used: spot size 400 μm, five spots for each wall, power 125 mW, and arterial/venous fluence 100/90 J/cm(2) (spot duration 1/0.9 s). Mean operating time for arterial and venous microanastomoses was 7.3 ± 1.4 and 8.7 ± 1.0 min, respectively. Three anastomoses required a secondary laser application. Arterial and venous patency rates were 100 % at the time of surgery. The success rate for the 11 procedures assessed clinically and with the Doppler was 100 %. The technique is compared to the current literature. The 1950-nm LAMA is a reliable tool with excellent results in emergency hand surgery. The system is very compact and transportable for utilization in the emergency operating room.

  11. 1018 nm Yb-doped high-power fiber laser pumped by broadband pump sources around 915 nm with output power above 100 W

    DEFF Research Database (Denmark)

    Midilli, Yakup; Efunbajo, Oyewole Benjamin; Şimşek, Bartu

    2017-01-01

    laser were also addressed in this study. Finally, we have tested this system for high power experimentation and obtained 67% maximum optical-to-optical efficiency at an approximately 110 W output power level. To the best of our knowledge, this is the first 1018 nm ytterbium-doped all-fiber laser pumped...

  12. Structure, spectroscopic properties and laser performance of Nd:YNbO4 at 1066 nm

    Science.gov (United States)

    Ding, Shoujun; Peng, Fang; Zhang, Qingli; Luo, Jianqiao; Liu, Wenpeng; Sun, Dunlu; Dou, Renqin; Sun, Guihua

    2016-12-01

    We have demonstrated continuous wave (CW) laser operation of Nd:YNbO4 crystal at 1066 nm for the first time. A maximum output power of 1.12 W with the incident power of 5.0 W is successfully achieved corresponding to an optical-to-optical conversion efficiency of 22.4% and a slope efficiency of 24.0%. The large absorption cross section (8.7 × 10-20 cm2) and wide absorption band (6 nm) at around 808 nm indicates the good pumping efficiency by laser diodes (LD). The small emission cross section (29 × 10-20 cm2) and relative long lifetime of the 4F3/2 → 4I11/2 transition indicates good energy storage capacity of Nd:YNbO4. Moreover, the raw materials of Nd:YNbO4 are stable, thus, it can grow high-quality and large-size by Czochralski (CZ) method. Therefore the Nd:YNbO4 crystal is a potentially new laser material suitable for LD pumping.

  13. Comparison of a long-pulse Nd:YAG laser and a combined 585/1,064-nm laser for the treatment of acne scars: a randomized split-face clinical study.

    Science.gov (United States)

    Min, Seong U K; Choi, Yu Sung; Lee, Dong Hun; Yoon, Mi Young; Suh, Dae Hun

    2009-11-01

    Nonablative laser is gaining popularity because of the low risk of complications, especially in patients with darker skin. To compare the efficacy and safety of a long-pulse neodymium-doped yttrium aluminium garnet (Nd:YAG) laser and a combined 585/1,064-nm laser for the treatment of acne scars. Nineteen patients with mild to moderate atrophic acne scars received four long-pulse Nd:YAG laser or combined 585/1,064-nm laser treatment sessions at fortnightly intervals. Treatments were administered randomly in a split-face manner. Acne scars showed mild to moderate improvement, with significant Echelle d'évaluation clinique des cicatrices d'acné (ECCA) score reductions, after both treatments. Although intermodality differences were not significant, combined 585/1,064-nm laser was more effective for deep boxcar scars. In patients with combined 585/1,064-nm laser-treated sides that improved more than long-pulse Nd:YAG laser-treated sides, ECCA scores were significantly lower for combined 585/1,064-nm laser treatment. Histologic evaluations revealed significantly greater collagen deposition, although there was no significant difference between the two modalities. Patient satisfaction scores concurred with physicians' evaluations. Both lasers ameliorated acne scarring with minimal downtime. In light of this finding, optimal outcomes might be achieved when laser treatment types are chosen after considering individual scar type and response.

  14. All-solid-state cw frequency-doubling Nd:YLiF4/LBO blue laser with 4.33 W output power at 454 nm under in-band diode pumping at 880 nm.

    Science.gov (United States)

    Lü, Yanfei; Zhang, Xihe; Cheng, Weibo; Xia, Jing

    2010-07-20

    We generated efficient blue laser output at 454 nm by intracavity frequency doubling of a continuous-wave (cw) diode-pumped Nd:YLiF(4) (Nd:YLF) laser at 908 nm based on the (4)F(3/2)-(4)I(9/2) transition. With 32.8 W of incident pump power at 880 nm and the frequency-doubling crystal LiB(3)O(5), a level as high as 4.33 W of cw output power at 454 nm is achieved, corresponding to an optical conversion efficiency of 13.2% with respect to the incident pump power. To the best of our knowledge, this is the first blue laser at 454 nm generated by intracavity frequency doubling of a diode-pumped Nd:YLF.

  15. Aplicação do laser 808nm na dor articular crônica de ratos Wistar Aplication of 808nm laser in chronic joint pain in Wistar rats

    Directory of Open Access Journals (Sweden)

    Gladson Ricardo Flor Bertolini

    2009-08-01

    Full Text Available Durante o processo inflamatório, alguns tipos de células predominam e estão envolvidos com a produção de dor. O laser de baixa potência mostra-se útil no controle de mediadores inflamatórios, mas a ampla divergência nos parâmetros dosimétricos, conduz a variações nos resultados positivos. O objetivo deste estudo foi analisar o uso do laser 808nm, na dor articular crônica e edema de ratos Wistar submetidos a sinovite. Foram utilizados 10 ratos Wistar, divididos em dois grupos: GC - indução de sinovite em joelho direito e tratamento placebo; GT - indução de sinovite e irradiado com laser 10J/cm². Para a produção de sinovite foram injetados 100µl de formalina a 5%, no espaço articular tibiofemoral direito. A avaliação da dor ocorreu pelo tempo de elevação da pata (TEP. No 10º dia após a indução de sinovite, iniciou-se o tratamento com laser sobre a face articular medial do joelho, procedimento mantido no decorrer de 10 dias. Os resultados mostraram que o laser apresentou efeitos analgésicos, visto que, para o grupo tratado, houve redução significativa nos valores de TEP, indicando redução da dor, quando comparados os valores pós-tratamento com os pré-tratamento, o que não ocorreu para o grupo que recebeu tratamento placebo; para o edema, o laser também mostrou redução significativa do mesmo. Concluiu-se que o laser 808nm, com 10J/cm², é eficaz na redução da dor articular crônica e edema, em animais submetidos a sinovite experimental.During the inflammatory process some kinds of cells are predominant and are involved with pain production. Low power laser seems to be useful in the control of inflammatory mediators, but wide divergence in the dosemetric parameters leads to variations in its positive results. The aim of this study was to assess the use of the 808nm laser in the chronic joint pain and edema of Wistar rats submitted to synovitis. Sample was composed of 10 Wistar rats divided in two groups

  16. Effects of various parameters of the 1064 nm Nd:YAG laser for the treatment of enlarged facial pores.

    Science.gov (United States)

    Roh, Mi Ryung; Chung, Hye Jin; Chung, Kee Yang

    2009-01-01

    A variety of treatment modalities have been used to reduce the size of enlarged facial pores without obvious success. To assess and compare the effects of various parameters of a 1064 nm Nd:YAG laser in the treatment of enlarged facial pores. This was a prospective intra-individual left-right comparative study. A total of 40 individuals with enlarged facial pores were recruited for this study. Ten individuals were respectively treated on one half of the face with a quasi long-pulsed 1064 nm Nd:YAG laser (method 1), a Q-switched 1064 nm Nd:YAG laser (method 2), both quasi long-pulsed and Q-switched 1064 nm Nd:YAG lasers without carbon-suspended lotion (method 3), and both quasi long-pulsed and Q-switched 1064 nm Nd:YAG lasers with carbon-suspended lotion (method 4). The other half of the face was left untreated as a control. Five laser sessions were performed with a 3-week interval. The pore sizes were measured using an image analysis program and the sebum level was measured with a Sebumeter before and after the treatments. The pore size and sebum level decreased in all four methods on the treated side compared to the control (p pore size and sebum level.

  17. Comparing the 810nm diode laser with conventional surgery in orthodontic soft tissue procedures.

    Science.gov (United States)

    Ize-Iyamu, I N; Saheeb, B D; Edetanlen, B E

    2013-09-01

    To compare the use of the 810nm diode laser with conventional surgery in the management of soft tissue mucogingival problems associated with orthodontic treatment. Orthodontic patients requiring different soft tissue surgical procedures were randomly assigned to receive conventional surgery or soft tissue diode laser, (wavelength 810 nm). Parameters documented include the type of anaesthesia used, intra and post operative pain, bleeding, the use of scalpel and sutures. The chi-squared test was used to test for significance at 95% confidence level. Probability values (p-values) less than 0.05 were regarded as significant. Only 2(16.7%) of the procedures carried out with the soft tissue laser required infiltration anaesthesia compared to 10 (90.9%) with conventional surgery and this was significant (Pdiode laser (Pdiode laser. No sutures were used in all soft tissue cases managed with the diode laser and this was significant (Plaser compared with conventional surgery. Orthodontic patients treated with the diode laser required less infiltration anaesthesia, had reduced bleeding during and after surgery, rapid postoperative haemostasis, elimination of the need for sutures and an improved postoperative comfort and healing.

  18. First demonstration of InGaP/InAlGaP based 608nm orange laser and 583nm yellow superluminescent diode

    KAUST Repository

    Majid, Mohammed Abdul

    2015-11-12

    We report on the first demonstration of InGaP/InAlGaP based orange semiconductor laser (OSL) and yellow superluminescent diode (YSLD) emitting at a wavelength of 608nm and 583nm respectively. The total output power of YSLD is ∼4.5mW which is the highest ever reported power on this material system at room-temperature.

  19. Disilicate Dental Ceramic Surface Preparation by 1070 nm Fiber Laser: Thermal and Ultrastructural Analysis

    Directory of Open Access Journals (Sweden)

    Carlo Fornaini

    2018-01-01

    Full Text Available Lithium disilicate dental ceramic bonding, realized by using different resins, is strictly dependent on micro-mechanical retention and chemical adhesion. The aim of this in vitro study was to investigate the capability of a 1070 nm fiber laser for their surface treatment. Samples were irradiated by a pulsed fiber laser at 1070 nm with different parameters (peak power of 5, 7.5 and 10 kW, repetition rate (RR 20 kHz, speed of 10 and 50 mm/s, and total energy density from 1.3 to 27 kW/cm2 and the thermal elevation during the experiment was recorded by a fiber Bragg grating (FBG temperature sensor. Subsequently, the surface modifications were analyzed by optical microscope, scanning electron microscope (SEM, and energy dispersive X-ray spectroscopy (EDS. With a peak power of 5 kW, RR of 20 kHz, and speed of 50 mm/s, the microscopic observation of the irradiated surface showed increased roughness with small areas of melting and carbonization. EDS analysis revealed that, with these parameters, there are no evident differences between laser-processed samples and controls. Thermal elevation during laser irradiation ranged between 5 °C and 9 °C. A 1070 nm fiber laser can be considered as a good device to increase the adhesion of lithium disilicate ceramics when optimum parameters are considered.

  20. Laser 830nm na viabilidade do retalho cutâneo de ratos submetidos à nicotina Laser 830nm on the viability of skin flaps in rats submitted of nicotine

    Directory of Open Access Journals (Sweden)

    Lais Mara Siqueira das Neves

    2011-01-01

    Full Text Available OBJETIVO: Investigar os possíveis efeitos da laserterapia com laser diodo 830nm ao se contrapor a ação da nicotina na viabilidade do retalho cutâneo em ratos. MÉTODOS: Foram utilizados 16 ratos Wistar, distribuídos em 2 grupos de 8: Grupo 1- submetido à técnica cirúrgica, para obtenção dos retalhos cutâneos randômicos de base cranial, com injeção subcutânea de nicotina em uma dose de 2mg/Kg/dia, uma semana antes e uma semana após o procedimento cirúrgico e simulação da radiação laser; Grupo 2- similar ao grupo 1, cujos retalhos cutâneos randômicos de base cranial foram submetidos à irradiação do laser imediatamente após a cirurgia e nos 4 dias subsequentes. Após a eutanásia, as áreas de necrose e de tecido viável foram examinadas através do método de pesagem do Gabarito de Papel e pelo método semi-automático de análise de imagens (Mini-Mop®. RESULTADOS: Os resultados foram analisados estatisticamente através do teste ANOVA. Os valores de porcentagem de área de necrose através do método de análise mostraram uma diminuição da área de necrose no grupo 2 onde foi aplicado laser. CONCLUSÃO: O laser 830nm foi eficaz na melhora da viabilidade do retalho cutâneo em ratos submetido à ação da nicotina. Nível de evidência II: Estudos terapêuticos - Investigação dos resultados do tratamento.OBJECTIVE: To investigate the possible effects of laser diode 830nm counter to the action of nicotine on the viability of the skin flap in rats. METHODS: 24 Wistar-albino rats were used, divided into 3 groups of 8: Group 1 - subject to the surgical technique to obtain the random skin flap in cranial base, subcutaneous injection of nicotine of 2mg/Kg/dia a week before and one week after surgery and simulation of laser. Group 2 - similar to group 1, the random skin flap in the cranial base were subjected to laser irradiation immediately after surgery and on thesubsequent 4 days. After euthanasia, areas of necrosis and

  1. High-power diode-end-pumped Tm:YLF slab laser delivering 189 W at 1890 nm

    CSIR Research Space (South Africa)

    Koen, W

    2010-09-01

    Full Text Available Laser Delivering 189 W at 1890 nm W. Koen, H.J. Strauss, C. Bollig and M.J.D. Esser CSIR National Laser Centre, Meiring Naude Road, Brummeria, Pretoria, 0001 wkoen@csir.co.za Abstract: We present a high-power Tm:YLF slab laser double...

  2. Trends in nanosecond melanosome microcavitation up to 1540 nm

    Science.gov (United States)

    Schmidt, Morgan S.; Kennedy, Paul K.; Noojin, Gary D.; Vincelette, Rebecca L.; Thomas, Robert J.; Rockwell, Benjamin A.

    2015-09-01

    Thresholds for microcavitation of bovine and porcine melanosomes were previously reported, using single nanosecond (ns) laser pulses in the visible (532 nm) and the near-infrared (NIR) from 1000 to 1319 nm. Here, we report average radiant exposure thresholds for bovine melanosome microcavitation at additional NIR wavelengths up to 1540 nm, which range from ˜0.159 J/cm2 at 800 nm to 4.5 J/cm2 at 1540 nm. Melanosome absorption coefficients were also estimated, and decreased with increasing wavelength. These values were compared to retinal pigment epithelium coefficients, and to water absorption, over the same wavelength range. Corneal total intraocular energy retinal damage threshold values were estimated and compared to the previous (2007) and recently changed (2014) maximum permissible exposure (MPE) safe levels. Results provide additional data that support the recent changes to the MPE levels, as well as the first microcavitation data at 1540 nm, a wavelength for which melanosome microcavitation may be an ns-pulse skin damage mechanism.

  3. Negative-tone imaging with EUV exposure for 14nm hp and beyond

    Science.gov (United States)

    Tsubaki, Hideaki; Nihashi, Wataru; Tsuchihashi, Toru; Fujimori, Toru; Momota, Makoto; Goto, Takahiro

    2015-03-01

    Manipulation of dissolution properties by changing organic solvent developer and rinse material provides a novel technology to obtain fine pattern beyond the limitation of imaging system based on alkaline developer. QCM study showed no swelling character in negative-tone imaging (NTI) process even for current developer of n-butyl acetate (nBA). Actually, NTI process has shown advantages on resolution and line-width roughness (LWR) in loose pitch around 30 ~ 45 nm hp as a consequence of its non-swelling character. On the other hand, bridge and collapse limited its resolution below 20 nm hp, indicating that non-negligible amount of swelling still exists for tight pitch resolution. We investigated effects of solubility parameter of organic solvents on resolution below 20 nm hp. A bridge was reduced with a decrease in the solubility parameter dp from nBA. On the other hand, much lower dp caused film remaining due to its extremely slow Rmax. Based on these results, we newly developed FN-DP301 containing organic solvent with smaller dp than nBA. Although rinse solvent gave negligible effects on bridge, there is a clear improvement on pattern collapse only in case of using new rinse solvent of FN-RP311. Lithographic performances of NTI process using nBA and FN-DP301 together with the other organic solvents were described in this paper under exposures with an E-beam and a EUV light. It is emphasized that 14 nm hp resolution was obtained only using FN-DP301 as a developer and FN-RP311 as a rinse under E-beam exposure. NTI showed 43% faster photospeed in comparison with PTI at 16 nm hp, indicating that NTI is applicable to obtain high throughput with maintaining resolution. In addition, sub-20 nm trench was obtained using NTI without bridge under EUV exposure, all of which are attributed to the low swelling character of NTI process. Similarly, NTI was able to print 20 nm dots using NXE:3100 with only a little peeling. Conversely CH patterning was significantly worse with NTI

  4. Novel treatment of Hori's nevus: A combination of fractional nonablative 2,940-nm Er:YAG and low-fluence 1,064-nm Q-switched Nd:YAG laser.

    Science.gov (United States)

    Tian, Brian Wei Cheng Anthony

    2015-01-01

    To demonstrate a combination laser therapy to treat Hori's nevus. A prospective study. A Singapore-based clinic. Five female patients, aged 30-46 years, with bilateral malar Hori's nevus. Photographs were taken before treatment and 1 month after laser treatment was completed. These were graded by three independent physicians. The patients were also asked to grade their treatment response subjectively. They were followed up for a total of 3 months after laser treatment to monitor recurrence. The fractional nonablative 2,940-nm Er:YAG laser with a fluence of 0.7 J/cm(2), spot size 12 mm, and frequency 15 Hz was used to perform a full-face single-pass treatment. Subsequently, a second pass and third pass over Hori's nevi were done bilaterally till the clinical endpoint of skin whitening. The 1,064-nm Q-switched (QS) Nd:YAG at a fluence of 2.0 J/cm(2), frequency 2 Hz, and 4-mm spot size was used to deliver multiple passes over Hori's nevus till erythema with mild petechiae appeared. We repeated the treatment once a week for 3 more consecutive weeks. All five patients had above 80% improvement in their pigmentation and two (skin type III) achieved complete 100% clearance. Based on the patients' subjective assessments, all five of them expressed satisfaction and felt that their pigmentation had improved. There were no complications noted. The fractional nonablative 2940 nm Er:YAG laser and Q-switched 1064nm laser Nd:YAG combination is an effective and safe treatment for Hori's nevus.

  5. Histologic analyses on the response of the skin to 1,927-nm fractional thulium fiber laser treatment.

    Science.gov (United States)

    Kwon, In Ho; Bae, Youin; Yeo, Un-Cheol; Lee, Jin Yong; Kwon, Hyuck Hoon; Choi, Young Hee; Park, Gyeong-Hun

    2018-02-01

    The histologic responses to varied parameters of 1,927-nm fractional thulium fiber laser treatment have not yet been sufficiently elucidated. This study sought to evaluate histologic changes immediately after 1,927-nm fractional thulium fiber laser session at various parameters. The dorsal skin of Yucatan mini-pig was treated with 1,927-nm fractional thulium fiber laser at varied parameters, with or without skin drying. The immediate histologic changes were evaluated to determine the effects of varying laser parameters on the width and the depth of treated zones. The increase in the level of pulse energy widened the area of epidermal changes in the low power level, but increased the dermal penetration depth in the high power level. As the pulse energy level increased, the increase in the power level under the given pulse energy level more evidently made dermal penetration deeper and the treatment area smaller. Skin drying did not show significant effects on epidermal changes, but evidently increased the depth of dermal denaturation under both high and low levels of pulse energy. These results may provide important information to establish treatment parameters of the 1,927-nm fractional thulium fiber laser for various skin conditions.

  6. Split-face comparison of intense pulsed light and nonablative 1,064-nm Q-switched laser in skin rejuvenation.

    Science.gov (United States)

    Huo, Meng-Hua; Wang, Yong-Qian; Yang, Xin

    2011-01-01

    Multiple nonablative skin rejuvenation techniques have been used to improve facial aging. To compare rejuvenation efficiency of intense pulsed light (IPL) with nonablative 1,064-nm Q-switched laser in Asian patients. Twelve female subjects were enrolled and received five sessions of treatments at 2-week intervals. A split-face study was performed, with IPL applied to the left side of the face and nonablative 1,064-nm Q-switched laser to the right side. All assessments showed significant skin rejuvenation. For the improvement of skin texture, pore size, and sebum secretion, similar efficiency from laser and IPL was observed. For lightening of skin tone and macula, the IPL was more efficient than the laser after the first treatment, although no further clinical improvement resulted after three treatments. The laser gradually lightened the skin tone and macula and was ultimately more efficient than the IPL after five treatments. A series of IPL and nonablative 1,064-nm Q-switched laser treatments were performed with similar efficiency and safety for the improvement in skin texture, pore size, and sebum secretion. IPL was faster, but nonablative 1,064-nm Q-switched laser was more effective in improving skin tone and macula. © 2010 by the American Society for Dermatologic Surgery, Inc.

  7. Effects of blue diode laser (445 nm) and LED (430-480 nm) radiant heat treatments on dental glass ionomer restoratives

    Science.gov (United States)

    Dionysopoulos, Dimitrios; Tolidis, Kosmas; Strakas, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos; Gutknecht, Norbert

    2018-02-01

    The purpose of this in vitro study was to evaluate the effect of two radiant heat treatments on water sorption, solubility and surface roughness of three conventional glass ionomer cements by using a blue diode laser (445 nm) and a light emitting diode (LED) unit (430-480 nm). Thirty disk-shaped specimens were prepared for each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: Group 1 was the control group, in Group 2 the specimens were irradiated for 60 s at the top surface using a LED light-curing unit and in Group 3 the specimens were irradiated for 60 s at the top surface using a blue light diode laser. Statistical analysis was performed using one-way ANOVA and Tukey post hoc tests at a level of significance of a = 0.05. Radiant heat treatments with both laser and LED devices significantly decreased water sorption and solubility (p tested GICs. Blue diode laser treatment was seemed to be more effective compared to LED treatment for some of the tested materials. There were no changes in surface roughness of the GICs after the treatments (p > 0.05). Among the tested materials there were differences in water sorption and solubility (p 0.05). The use of the blue diode laser for this radiant heat treatment was harmless for the surface of the tested GICs and may be advantageous for the longevity of their restorations.

  8. Structural and electronic characterization of 355 nm laser-crystallized silicon: Interplay of film thickness and laser fluence

    International Nuclear Information System (INIS)

    Semler, Matthew R.; Swenson, Orven F.; Hoey, Justin M.; Guruvenket, Srinivasan; Gette, Cody R.; Hobbie, Erik K.

    2014-01-01

    We present a detailed study of the laser crystallization of amorphous silicon thin films as a function of laser fluence and film thickness. Silicon films grown through plasma-enhanced chemical vapor deposition were subjected to a Q-switched, diode-pumped solid-state laser operating at 355 nm. The crystallinity, morphology, and optical and electronic properties of the films are characterized through transmission and reflectance spectroscopy, resistivity measurements, Raman spectroscopy, X-ray diffraction, atomic force microscopy, and optical and scanning-electron microscopy. Our results reveal a unique surface morphology that strongly couples to the electronic characteristics of the films, with a minimum laser fluence at which the film properties are optimized. A simple scaling model is used to relate film morphology to conductivity in the laser-processed films

  9. Generation of 25-TW Femtosecond Laser Pulses at 515 nm with Extremely High Temporal Contrast

    Directory of Open Access Journals (Sweden)

    Marco Hornung

    2015-12-01

    Full Text Available We report on the frequency doubling of femtosecond laser pulses at 1030 nm center wavelength generated from the fully diode-pumped laser system POLARIS. The newly generated pulses at a center wavelength of 515 nm have a pulse energy of 3 J with a pulse duration of 120 fs. On the basis of initially ultra-high contrast seed pulses we expect a temporal intensity contrast better 10 17 200 ps before the peak of the main pulse. We analyzed the temporal intensity contrast from milliseconds to femtoseconds with a dynamic range covering more than 20 orders of magnitude. The pulses were focussed with a f/2-focussing parabola resulting in a peak intensity exceeding 10 20 W / cm 2 . The peak power and intensity are to the best of our knowledge the highest values for 515 nm-laser-pulses achieved so far.

  10. Laser welding and collagen crosslinks

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, K.M.; Last, J.A. [California Univ., Davis, CA (United States). Dept. of Medicine; Small, W. IV; Maitland, D.J.; Heredia, N.J.; Da Silva, L.B.; Matthews, D.L. [Lawrence Livermore National Lab., CA (United States)

    1997-02-20

    Strength and stability of laser-welded tissue may be influenced, in part, by effects of laser exposure on collagen crosslinking. We therefore studied effects of diode laser exposure (805 nm, 1-8 watts, 30 seconds) + indocyanine green dye (ICG) on calf tail tendon collagen crosslinks. Effect of ICG dye alone on crosslink content prior to laser exposure was investigated; unexpectedly, we found that ICG-treated tissue had significantly increased DHLNL and OHP, but not HLNL. Laser exposure after ICG application reduced elevated DHLNL and OHP crosslink content down to their native levels. The monohydroxylated crosslink HLNL was inversely correlated with laser output (p<0.01 by linear regression analysis). DHLNL content was highly correlated with content of its maturational product, OHP, suggesting that precursor-product relations are maintained. We conclude that: (1)ICG alone induces DHLNL and OHP crosslink formation; (2)subsequent laser exposure reduces the ICG-induced crosslinks down to native levels; (3)excessive diode laser exposure destroys normally occurring HLNL crosslinks.

  11. Tritium recovery from co-deposited layers using 193-nm laser

    Science.gov (United States)

    Shu, W. M.; Kawakubo, Y.; Nishi, M. F.

    Recovery of tritium from co-deposited layers formed in deuterium-tritium plasma operations of the TFTR (Tokamak Fusion Test Reactor) was investigated by the use of an ArF excimer laser operating at the wavelength of 193 nm. At the laser energy density of 0.1 J/cm2, a transient spike of the tritium-release rate was observed at initial irradiation. Hydrogen isotopes were released in the form of hydrogen-isotope molecules during the laser irradiation in vacuum, suggesting that tritium can be recovered readily from the released gases. In a second experiment, hydrogen (tritium) recovery from the co-deposited layers on JT-60 tiles that had experienced hydrogen-plasma operations was investigated by laser ablation with a focused beam of the excimer laser. The removal rate of the co-deposited layers was quite low when the laser energy density was smaller than the ablation threshold (1.0 J/cm2), but reached 1.1 μm/pulse at the laser energy density of 7.6 J/cm2. The effective absorption coefficient in the co-deposited layers at the laser wavelength was determined to be 1.9 μm-1. The temperature of the surface during the irradiation at the laser energy density of 0.5 J/cm2 was measured on the basis of Planck's law of radiation, and the maximum temperature during the irradiation decreased from 3570 K at the initial irradiation to 2550 K at the 1000th pulse of the irradiation.

  12. Eye safe high power laser diode in the 1410-1550nm range

    Science.gov (United States)

    Boucart, Julien; de Largy, Brian; Kearley, Mark; Lichtenstein, Norbert

    2010-02-01

    The demand for high power lasers emitting in the 14xx-15xxnm range is growing for applications in fields such as medical or homeland security. We demonstrate high power laser diodes with emission at 1430, 1470 and 1560 nm. Single multimode emitters at 1470nm emit about 3.5W in CW operation. Power conversion efficiency can reach values as high as 38.5%. With this base material, single and multi-emitter fiber coupled modules are built. Additionally, bars on passive and microchannel coolers are fabricated that deliver 25W and 38W respectively in CW mode, while obtaining more than 80 W in pulsed mode. All reliability tests show an outstanding stability of the material with no signs of wearout after 3750 hrs under strong acceleration conditions.

  13. Efficient quasi-three-level Nd:YAG laser at 946 nm pumped by a tunable external cavity tapered diode laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Tidemand-Lichtenberg, Peter

    2010-01-01

    Using a tunable external cavity tapered diode laser (ECDL) pumped quasi-three-level Nd:YAG laser, a fivefold reduction in threshold and twofold increase in slope efficiency is demonstrated when compared to a traditional broad area diode laser pump source. A TEM00 power of 800 mW with 65% slope...... efficiency is obtained, the highest reported TEM00 power from any 946 nm Nd:YAG laser pumped by a single emitter diode laser pump source. A quantum efficiency of 0.85 has been estimated from experimental data using a simple quasi-three-level model. The reported value is in good agreement with published...

  14. Tunable high-power narrow-spectrum external-cavity diode laser at 675 nm as a pump source for UV generation

    DEFF Research Database (Denmark)

    Chi, Mingjun; Jensen, Ole Bjarlin; Erbert, Gotz

    2011-01-01

    High-power narrow-spectrum diode laser systems based on tapered gain media in external cavity are demonstrated at 675 nm. Two 2-mm-long amplifiers are used, one with a 500-µm-long ridge-waveguide section (device A), the other with a 750-µm-long ridge-waveguide section (device B). The laser system...... of 1.0 W. The laser system B based on device B is tunable from 666 to 685 nm. As high as 1.05 W output power is obtained around 675.67 nm. The emission spectral bandwidth is less than 0.07 nm throughout the tuning range, and the beam quality factor M2 is 1.13 at an output power of 0.93 W. The laser...... system B is used as a pump source for the generation of 337.6 nm UV light by single-pass frequency doubling in a BIBO crystal. An output power of 109 µW UV light, corresponding to a conversion efficiency of 0.026%W-1 is attained....

  15. A combined remote Raman and LIBS instrument for characterizing minerals with 532 nm laser excitation.

    Science.gov (United States)

    Sharma, Shiv K; Misra, Anupam K; Lucey, Paul G; Lentz, Rachel C F

    2009-08-01

    The authors have developed an integrated remote Raman and laser-induced breakdown spectroscopy (LIBS) system for measuring both the Raman and LIBS spectra of minerals with a single 532 nm laser line of 35 mJ/pulse and 20 Hz. The instrument has been used for analyzing both Raman and LIBS spectra of carbonates, sulfates, hydrous and anhydrous silicates, and iron oxide minerals in air. These experiments demonstrate that by focusing a frequency-doubled 532 nm Nd:YAG pulsed laser beam with a 10x beam expander to a 529-microm diameter spot on a mineral surface located at 9 m, it is possible to measure simultaneously both the remote Raman and LIBS spectra of calcite, gypsum and olivine by adjusting the laser power electronically. The spectra of calcite, gypsum, and olivine contain fingerprint Raman lines; however, it was not possible to measure the remote Raman spectra of magnetite and hematite at 9 m because of strong absorption of 532 nm laser radiation and low intensities of Raman lines from these minerals. The remote LIBS spectra of both magnetite and hematite contain common iron emission lines but show difference in the minor amount of Li present in these two minerals. Remote Raman and LIBS spectra of a number of carbonates, sulfates, feldspars and phyllosilicates at a distance of 9 m were measured with a 532-nm laser operating at 35 mJ/pulse and by changing photon flux density at the sample by varying the spot diameter from 10 mm for Raman to 530 microm for LIBS measurements. The complementary nature of these spectra is highlighted and discussed. The combined Raman and LIBS system can also be re-configured to perform micro-Raman and micro-LIBS analyses, which have applications in trace/residue analysis and analysis of very small samples in the nano-gram range.

  16. High-power diode-side-pumped intracavity-frequency-doubled continuous wave 532 nm laser

    International Nuclear Information System (INIS)

    Zhang Yuping; Zhang Huiyun; Zhong Kai; Li Xifu; Wang Peng; Yao Jianquan

    2007-01-01

    An efficient and high-power diode-side-pumped cw 532 nm green laser based on a V-shaped cavity geometry, and capable of generating 22.7 W green radiation with optical conversion efficiency of 8.31%, has been demonstrated. The laser is operated with rms noise amplitude of less than 1% and with M 2 -parameter of about 6.45 at the top of the output power. This laser has the potential for scaling to much higher output power. (authors)

  17. Broadband multi-wavelength Brillouin lasers with an operating wavelength range of 1500–1600 nm generated by four-wave mixing in a dual wavelength Brillouin fiber laser cavity

    Science.gov (United States)

    Li, Q.; Jia, Z. X.; Weng, H. Z.; Li, Z. R.; Yang, Y. D.; Xiao, J. L.; Chen, S. W.; Huang, Y. Z.; Qin, W. P.; Qin, G. S.

    2018-05-01

    We demonstrate broadband multi-wavelength Brillouin lasers with an operating wavelength range of 1500–1600 nm and a frequency separation of ~9.28 GHz generated by four-wave mixing in a dual wavelength Brillouin fiber laser cavity. By using one continuous-wave laser as the pump source, multi-wavelength Brillouin lasers with an operating wavelength range of 1554–1574 nm were generated via cascaded Brillouin scattering and four-wave mixing. Interestingly, when pumped by two continuous-wave lasers with an appropriate frequency separation, the operating wavelength range of the multi-wavelength Brillouin lasers was increased to 1500–1600 nm due to cavity-enhanced cascaded four-wave mixing among the frequency components generated by two pump lasers in the dual wavelength Brillouin laser cavity.

  18. High-energy high-efficiency Nd:YLF laser end-pump by 808 nm diode

    Science.gov (United States)

    Ma, Qinglei; Mo, Haiding; Zhao, Jay

    2018-04-01

    A model is developed to calculate the optimal pump position for end-pump configuration. The 808 nm wing pump is employed to spread the absorption inside the crystal. By the optimal laser cavity design, a high-energy high-efficiency Nd:YLF laser operating at 1053 nm is presented. In cw operation, a 13.6 W power is obtained with a slope efficiency of 51% with respect to 30 W incident pump power. The beam quality is near diffraction limited with M2 ∼ 1.02. In Q-switch operation, a pulse energy of 5 mJ is achieved with a peak power of 125 kW at 1 kHz repetition rate.

  19. Potential role of S100A8 in skin rejuvenation with the 1064-nm Q-switched Nd:YAG laser.

    Science.gov (United States)

    Qin, Yan; Qin, Xiaofeng; Xu, Peng; Zhi, Yuanting; Xia, Weili; Dang, Yongyan; Gu, Jun; Ye, Xiyun

    2018-04-01

    The 1064-nm Q-switched Nd:YAG laser is demonstrated to be effective for non-ablative skin rejuvenation, but the molecular mechanism by which dermis responses to laser-induced damage and initiates skin remodeling is still unclear. HaCaT cells and 3T3 skin fibroblasts were irradiated with the 1064-nm Q-switched Nd:YAG laser at the different doses. Then, cells were collected and lysed for PCR and Western blot analysis. Cell viability was detected by Cell Counting Kit-8 (CCK-8) before and after laser irradiation. The expressions of S100A8, advanced glycosylation end product-specific receptor (RAGE) and inflammatory cytokines in two cell lines were markedly upregulated after laser treatments. The PCR, Western blot, and ELISA analysis showed the significant increase of type I and III procollagen in the 3T3 cells treated with the 1064-nm laser. Interestingly, si S100A8 effectively inhibited the expression of cytokines and collagen, while S100A8 treatments significantly increased them. P-p38 and p-p65 levels were also elevated after the 1064-nm laser irradiation, which is positively related with S100A8. Cell viability and reactive oxygen species (ROS) levels were not changed, while the content of superoxidase dismutase (SOD) in two cells was increased after laser irradiation. Our results demonstrated that the overexpression of S100A8 induced by the 1064-nm laser irradiation triggered inflammatory reactions in skin cells. The inflammatory microenvironment and improvement of skin antioxidant capacity contribute to new collagen synthesis in the skin cells. Thus, S100A8 was required for laser-induced new collagen synthesis in skin cells. p38/MAPK and NF-κB signal pathways were involved in S100A8-mediated inflammatory reactions in response to laser irradiation.

  20. Effect on isoflavone of soybean seedlings by 532nm laser irradiation

    Science.gov (United States)

    Tian, J.; Jin, L. H.; Li, J. M.; Shen, B. J.; Wang, C. Y.; Lu, X.; Zhao, X. L.

    2010-02-01

    We took soybeans as experimental substance to study how the 532nm laser with different power density and irradiation time affected the pullulation ratio of the soybeans, average height of seedlings and the isoflavone content of seedlings' cotyledon and laminae. The mechanism that laser pretreatment of soybean seeds could increase the isoflavone content of the seedlings was discussed in such both aspects as the efficiency of the photosynthesis and the activity of a phenylalanine ammonia-lyase (PAL) as an initial enzyme for synthesizing the isoflavone. The results showed that after the soybean seeds were pretreated by laser, the activity of the PAL and the resultants of the photosynthesis such as the sugar of dissolubility, the sucrose, and the amylum all increased with the soybean seeds irradiated by laser in which the effect on the soybean seeds pretreated by 15mW/mm2 laser for 5 min was the most obvious. As a result, the photosynthesis efficiency of the soybean seedlings increased after being pretreated by laser, which might offer the foundation for accumulating a large amount of isoflavone.

  1. Production of active lysozyme films by matrix assisted pulsed laser evaporation at 355 nm

    DEFF Research Database (Denmark)

    Purice, Andreea; Schou, Jørgen; Kingshott, P.

    2007-01-01

    Thin lysozyme films have been produced in a dry environment by MAPLE (matrix assisted pulsed laser evaporation) from a water ice matrix irradiated by laser light at 355 nm above the absorption threshold of the protein. A significant part of the lysozyme molecules are transferred to the film without...

  2. Mechanistic comparison of pulse laser induced phase separation of particulates from cellulose paper at 213 nm and 532 nm

    International Nuclear Information System (INIS)

    Arif, S.; Forster, M.; Kautek, W.; Bushuk, S.; Kouzmouk, A.; Tatur, H.; Batishche, S.

    2013-01-01

    The laser-induced phase separation of charcoal particles on additive-free cotton linters cellulose paper was investigated by electron and optical microscopy, colorimetry, and diffuse reflectance FT-IR. The fibre bundles were vaporised in depth of several 10 μm above destruction fluence thresholds using visible 532 nm radiation. This is in contrast to mid-ultraviolet 213 nm radiation, where only the top fibre bundles were modified and partially evaporated. The colorimetric lightness results generally represented the cleaning status, whereas the colorimetric yellowing data represented irreversible chemical and/or photochemical changes. Charcoal-contaminated paper treated with visible and mid-ultraviolet radiation exhibited yellowing, whereas uncontaminated did not. This suggests that the electron-rich plasma generated by the evaporation of the particles heats the adjacent substrate and also excludes oxygen. Mid-ultraviolet, in contrast to visible radiation, shows particle removal always accompanied by paper destruction. IR spectroscopy results suggest cross-linking by ether bonds near the destruction threshold, but do not prove the formation of oxidation products and double bonds as the basis of the yellowing. A ''cleaning window'' between the cleaning threshold (0.1 J/cm 2 ) and the paper destruction threshold (2.9 J/cm 2 ) with a pulse number of 2 is provided by visible 532 nm laser treatment. (orig.)

  3. 375-nm ultraviolet-laser based non-line-of-sight underwater optical communication

    KAUST Repository

    Sun, Xiaobin; Cai, Wenqi; Alkhazragi, Omar; Ooi, Ee-Ning; He, Hongsen; Chaaban, Anas; Shen, Chao; Oubei, Hassan M.; Khan, Mohammed Zahed Mustafa; Ng, Tien Khee; Alouini, Mohamed-Slim; Ooi, Boon S.

    2018-01-01

    For circumventing the alignment requirement of line-of-sight (LOS) underwater wireless optical communication (UWOC), we demonstrated a non-line-of-sight (NLOS) UWOC link adequately enhanced using ultraviolet (UV) 375-nm laser. Path loss was chosen

  4. Laser-Assisted Liposuction Using the Novel 1,444-nm Nd:YAG Laser for the Treatment of Gynecomastia: A Pilot Study.

    Science.gov (United States)

    Yoo, Kwang Ho; Bae, Jung Min; Won, Chae Young; Chung, Yu Seok; Goo, Boncheol; Rho, Yong Kwan; Kim, Gyong Moon; Lee, Jongwon; Ahn, Byeong Heon; Kim, Beom Joon

    2015-01-01

    Laser-assisted liposuction (LAL) is currently widely used to reduce localized fat. A novel Nd:YAG laser that uses a wavelength of 1,444 nm, which is better absorbed by fat, has recently been introduced. In this study, we investigated the efficacy of 1,444-nm Nd:YAG LAL for the treatment of gynecomastia. Thirteen Korean male patients (20-28 years, mean age 23 years) diagnosed with gynecomastia were enrolled in this study. All patients were treated by LAL with 1,444-nm Nd:YAG laser (100 µs pulse width, 40 Hz frequency, 300 mJ pulse energy and 12 W power with continuous emission) after tumescent anesthetic infiltration and were then evaluated. Outcome was assessed using the following 4 methods: (1) clinical assessment with photographs obtained before and 12 weeks after LAL treatment, (2) comparison of pre- and postoperative patient chest circumferences, (3) computed tomography (CT) scans to evaluate changes in breast thickness and (4) a patient satisfaction survey at the end of the study. After 12 weeks, most patients (84.5%) showed an improvement greater than 50%. Mean chest circumference was significantly reduced from 109.6 ± 8.2 to 101.2 ± 4.4 cm 12 weeks after LAL (p Gynecomastia can be safely treated with 1,444-nm Nd:YAG LAL to reduce fatty tissue and total breast volume. © 2015 S. Karger AG, Basel.

  5. Single-treatment skin tightening by radiofrequency and long-pulsed, 1064-nm Nd: YAG laser compared.

    Science.gov (United States)

    Key, Douglas J

    2007-02-01

    To compare single-treatment facial skin tightening achieved with the current radiofrequency (RF) protocol with single-treatment tightening achieved with the long-pulsed, 1064-nm Nd:YAG laser. A total of 12 patients were treated with RF energy on one side of the face and laser energy on the other. Results were evaluated on a numerical scale (0-12 with 12 = greatest enhancement) from pre- and posttreatment photographs by a blinded panel. Upper face improvement (posttreatment score minus pretreatment score) was essentially the same on both sides (30.2 and 31.3% improvement for laser and RF, respectively, P=0.89). Lower face improvement was greater in the laser-treated side (35.7 and 23.8% improvement for laser and RF, respectively), but the difference was not significant (P=0.074). Overall face improvement was significantly greater on the laser-treated side (47.5 and 29.8% improvement for laser and RF, respectively, P=0.028). A single high-fluence treatment with the long-pulse 1064-nm Nd:YAG laser may improve skin laxity more than a single treatment with the RF device. Further controlled split-face or very large non-self controlled studies are needed to conclusively determine the relative efficacies of the two technologies. (c) 2007 Wiley-Liss, Inc.

  6. Q-switched Erbium-doped fiber laser at 1600 nm for photoacoustic imaging application

    Energy Technology Data Exchange (ETDEWEB)

    Piao, Zhonglie [Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 609-735 (Korea, Republic of); Beckman Laser Institute, Department of Biomedical Engineering, University of California, Irvine, California 92612 (United States); Zeng, Lvming; Chen, Zhongping, E-mail: z2chen@uci.edu, E-mail: ckim@pusan.ac.kr [Beckman Laser Institute, Department of Biomedical Engineering, University of California, Irvine, California 92612 (United States); Kim, Chang-Seok, E-mail: z2chen@uci.edu, E-mail: ckim@pusan.ac.kr [Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 609-735 (Korea, Republic of)

    2016-04-04

    We present a nanosecond Q-switched Erbium-doped fiber (EDF) laser system operating at 1600 nm with a tunable repetition rate from 100 kHz to 1 MHz. A compact fiber coupled, acousto-optic modulator-based EDF ring cavity was used to generate a nanosecond seed laser at 1600 nm, and a double-cladding EDF based power amplifier was applied to achieve the maximum average power of 250 mW. In addition, 12 ns laser pulses with the maximum pulse energy of 2.4 μJ were obtained at 100 kHz. Furthermore, the Stokes shift by Raman scattering over a 25 km long fiber was measured, indicating that the laser can be potentially used to generate the high repetition rate pulses at the 1.7 μm region. Finally, we detected the photoacoustic signal from a human hair at 200 kHz repetition rate with a pulse energy of 1.2 μJ, which demonstrates that a Q-switched Er-doped fiber laser can be a promising light source for the high speed functional photoacoustic imaging.

  7. 2940-nm Er:YAG fractional laser enhanced the effect of topical drug for psoriasis.

    Science.gov (United States)

    Li, Ruilian; Zhou, Jun; Su, Hui; Wang, Mei; Wang, Yongxian; Xiao, Shengxiang; Ma, Huiqun

    2017-08-01

    We observed the promoting effects of the 2940-nm erbium:YAG (Er:YAG) fractional laser in topical drug delivery for psoriasis. A total of five (four males and one female) recalcitrant psoriasis patients were given laser treatment eight times at 1-week intervals with the following parameters: 5-11% spot density and 100-μm energy depth. The psoriatic skin lesions on the left knee and the corresponding lesions at the right ones of each psoriasis patient were randomly divided into two groups: laser + topical drug group (L) and drug alone group (D). The psoriatic lesions in both groups were treated with the same topical treatment (calcipotriol ointment). The corresponding psoriatic lesions in the L group received extra 2940-nm Er:YAG laser irradiation before topical treatment. The photos of psoriatic lesions were taken before each treatment. The final photos were obtained from the patients at the seventh day after the final treatment. Drug alone or in combination with laser Er:YAG both reduced psoriatic lesions. However, with the increase in the number of treatments, increasing differences were observed between the treatment and the control sides. The therapeutic outcomes in the L groups were better than those in the D groups. Psoriasis area and severity index (PASI) scores for five cases of both groups were decreased. However, the scores in the L groups were lower than those in the D groups. The use of 2940 nm Er:YAG promoted the absorption of topical drugs for psoriasis, improving the therapeutic effect.

  8. Tribological performance of sub-100-nm femtosecond laser-induced periodic surface structures on titanium

    Energy Technology Data Exchange (ETDEWEB)

    Bonse, J., E-mail: joern.bonse@bam.de [BAM Bundesanstalt für Materialforschung und -prüfung, Unter den Eichen 87, D-12205 Berlin (Germany); Höhm, S. [Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie (MBI), Max-Born-Straße 2A, D-12489 Berlin (Germany); Koter, R.; Hartelt, M.; Spaltmann, D.; Pentzien, S. [BAM Bundesanstalt für Materialforschung und -prüfung, Unter den Eichen 87, D-12205 Berlin (Germany); Rosenfeld, A. [Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie (MBI), Max-Born-Straße 2A, D-12489 Berlin (Germany); Krüger, J. [BAM Bundesanstalt für Materialforschung und -prüfung, Unter den Eichen 87, D-12205 Berlin (Germany)

    2016-06-30

    Graphical abstract: - Highlights: • Large areas covered with sub-100 nm LIPSS (HSFL) were manufactured by fs-laser irradiation on titanium surfaces. • Tribological performance of HSFL covered areas was qualified in reciprocal sliding tests in two different lubricating oils. • HSFL on titanium do not endure the tribological tests. • For a beneficial tribological performance, the tribological sample deformation must be smaller than the LIPSS modulation depth. - Abstract: Sub-100-nm laser-induced periodic surface structures (LIPSS) were processed on bulk titanium (Ti) surfaces by femtosecond laser pulse irradiation in air (30 fs pulse duration, 790 nm wavelength). The laser peak fluence, the spatial spot overlap, and the number of overscans were optimized in a sample-scanning geometry in order to obtain large surface areas (5 mm × 5 mm) covered homogeneously by the LIPSS. The laser-processed regions were characterized by optical microscopy (OM), white light interference microscopy (WLIM) and scanning electron microscopy (SEM). The friction coefficient of the nanostructured surfaces was tested during 1000 cycles under reciprocal sliding conditions (1 Hz, 1.0 N normal load) against a 10-mm diameter ball of hardened 100Cr6 steel, both in paraffin oil and in engine oil used as lubricants. Subsequently, the corresponding wear tracks were qualified by OM, SEM, and energy dispersive X-ray analyses (EDX). The results of the tribological tests are discussed and compared to that obtained for near wavelength-sized fs-LIPSS, processed under somewhat different irradiation conditions. Some constraints for a beneficial effect of LIPSS on the tribological performance are provided.

  9. Tribological performance of sub-100-nm femtosecond laser-induced periodic surface structures on titanium

    International Nuclear Information System (INIS)

    Bonse, J.; Höhm, S.; Koter, R.; Hartelt, M.; Spaltmann, D.; Pentzien, S.; Rosenfeld, A.; Krüger, J.

    2016-01-01

    Graphical abstract: - Highlights: • Large areas covered with sub-100 nm LIPSS (HSFL) were manufactured by fs-laser irradiation on titanium surfaces. • Tribological performance of HSFL covered areas was qualified in reciprocal sliding tests in two different lubricating oils. • HSFL on titanium do not endure the tribological tests. • For a beneficial tribological performance, the tribological sample deformation must be smaller than the LIPSS modulation depth. - Abstract: Sub-100-nm laser-induced periodic surface structures (LIPSS) were processed on bulk titanium (Ti) surfaces by femtosecond laser pulse irradiation in air (30 fs pulse duration, 790 nm wavelength). The laser peak fluence, the spatial spot overlap, and the number of overscans were optimized in a sample-scanning geometry in order to obtain large surface areas (5 mm × 5 mm) covered homogeneously by the LIPSS. The laser-processed regions were characterized by optical microscopy (OM), white light interference microscopy (WLIM) and scanning electron microscopy (SEM). The friction coefficient of the nanostructured surfaces was tested during 1000 cycles under reciprocal sliding conditions (1 Hz, 1.0 N normal load) against a 10-mm diameter ball of hardened 100Cr6 steel, both in paraffin oil and in engine oil used as lubricants. Subsequently, the corresponding wear tracks were qualified by OM, SEM, and energy dispersive X-ray analyses (EDX). The results of the tribological tests are discussed and compared to that obtained for near wavelength-sized fs-LIPSS, processed under somewhat different irradiation conditions. Some constraints for a beneficial effect of LIPSS on the tribological performance are provided.

  10. Novel treatment of Hori′s nevus: A combination of fractional nonablative 2,940-nm Er:YAG and low-fluence 1,064-nm Q-switched Nd:YAG laser

    Directory of Open Access Journals (Sweden)

    Brian Wei Cheng Anthony Tian

    2015-01-01

    Full Text Available Objective: To demonstrate a combination laser therapy to treat Hori′s nevus. Design: A prospective study. Setting: A Singapore-based clinic. Participants: Five female patients, aged 30-46 years, with bilateral malar Hori′s nevus. Measurements: Photographs were taken before treatment and 1 month after laser treatment was completed. These were graded by three independent physicians. The patients were also asked to grade their treatment response subjectively. They were followed up for a total of 3 months after laser treatment to monitor recurrence. Materials and Methods: The fractional nonablative 2,940-nm Er:YAG laser with a fluence of 0.7 J/cm 2, spot size 12 mm, and frequency 15 Hz was used to perform a full-face single-pass treatment. Subsequently, a second pass and third pass over Hori′s nevi were done bilaterally till the clinical endpoint of skin whitening. The 1,064-nm Q-switched (QS Nd:YAG at a fluence of 2.0 J/cm 2 , frequency 2 Hz, and 4-mm spot size was used to deliver multiple passes over Hori′s nevus till erythema with mild petechiae appeared. We repeated the treatment once a week for 3 more consecutive weeks. Results: All five patients had above 80% improvement in their pigmentation and two (skin type III achieved complete 100% clearance. Based on the patients′ subjective assessments, all five of them expressed satisfaction and felt that their pigmentation had improved. There were no complications noted. Conclusion: The fractional nonablative 2940 nm Er:YAG laser and Q-switched 1064nm laser Nd:YAG combination is an effective and safe treatment for Hori′s nevus.

  11. An expanded study of long-pulsed 1064 nm Nd:YAG laser treatment of basal cell carcinoma.

    Science.gov (United States)

    Ortiz, Arisa E; Anderson, R Rox; DiGiorgio, Catherine; Jiang, Shang I Brian; Shafiq, Faiza; Avram, Mathew M

    2018-02-13

    Basal cell carcinoma (BCC) is an indolent form of skin cancer that is rarely life threatening, but can cause significant cosmetic and functional morbidity. Surgical treatments often result in disfiguring scars, while topical therapies frequently result in recurrence. The need for a more effective nonsurgical alternative has led to the investigation of laser treatment of BCC. We have previously conducted a pilot study which showed 100% histologic clearance at high fluences. Treatments were well tolerated with no significant adverse events. The objective of this larger study was to confirm preliminary results that the 1064 nm Nd:YAG laser is a safe and effective method for treating non-facial BCC. This is an IRB-approved, prospective, multi-center study evaluating the safety and efficacy of the 1064 nm Nd:YAG laser for the treatment of BCC on the trunk and extremities. Thirty-three subjects seeking treatment for biopsy-proven BCC that did not meet the criteria for Mohs surgery were recruited. Subjects on current anticoagulation therapy, or with a history of immunosuppression were excluded. Subjects received one treatment with the 1064 nm Nd:YAG laser as follows: 5-6 mm spot, fluence of 125-140 J/cm 2 and a pulse duration of 7-10 ms. Standard excision with 5 mm clinical margins was performed at 30 days after laser treatment to evaluate clinical and histologic clearance of BCC. Standardized photographs and adverse assessments were taken at the baseline visit, immediately after laser treatment and on the day of excision. Thirty-one subjects completed the study. BCC tumors had a 90% (28 of 31 BCC tumors) histologic clearance rate after one treatment with the long-pulsed 1064 nm Nd:YAG laser. Treatments were generally well tolerated without any anesthesia. Immediate side effects included edema and erythema. At 1-month follow-up, some patients had residual crusting. No significant adverse events occurred. The 1064 nm long-pulsed Nd:YAG laser is an

  12. High-power cw laser bars of the 750 – 790-nm wavelength range

    International Nuclear Information System (INIS)

    Degtyareva, N S; Kondakov, S A; Mikayelyan, G T; Gorlachuk, P V; Ladugin, M A; Marmalyuk, Aleksandr A; Ryaboshtan, Yu L; Yarotskaya, I V

    2013-01-01

    We have developed the effective design of semiconductor heterostructures, which allow one to fabricate cw laser diodes emitting in the 750 – 790-nm spectral range. The optimal conditions for fabrication of GaAsP/AlGaInP/GaAs heterostructures by MOCVD have been determined. It is shown that the use of quantum wells with a precisely defined quantity mismatch reduces the threshold current density and increases the external differential efficiency. The results of studies of characteristics of diode laser bars fabricated from these heterostructures are presented. (lasers)

  13. Laser-plasma source parameters for Kr, Gd, and Tb ions at 6.6 nm

    Energy Technology Data Exchange (ETDEWEB)

    Masnavi, Majid; Szilagyi, John; Parchamy, Homaira; Richardson, Martin C. [The Townes Laser Institute, College of Optics and Photonics, University of Central Florida, 4000 Central Florida Blvd., Orlando, Florida 32816 (United States)

    2013-04-22

    There is increasing interest in extreme-ultraviolet (EUV) laser-based lamps for sub-10-nm lithography operating in the region of 6.6 nm. A collisional-radiative model is developed as a post-processor of a hydrodynamic code to investigate emission from resonance lines in Kr, Gd, and Tb ions under conditions typical for mass-limited EUV sources. The analysis reveals that maximum conversion efficiencies of Kr occur at 5 Multiplication-Sign 10{sup 10}W/cm{sup 2}, while for Gd and Tb it was Asymptotically-Equal-To 0.9%/2{pi}sr for laser intensities of (2-5) Multiplication-Sign 10{sup 12}W/cm{sup 2}.

  14. Efficient coupling of 527 nm laser beam power to a long scale-length plasma

    International Nuclear Information System (INIS)

    Moody, J.D.; Divol, L.; Glenzer, S.H.; MacKinnon, A.J.; Froula, D.H.; Gregori, G.; Kruer, W.L.; Meezan, N.B.; Suter, L.J.; Williams, E.A.; Bahr, R.; Seka, W.

    2006-01-01

    We experimentally demonstrate that application of laser smoothing schemes including smoothing by spectral dispersion (SSD) and polarization smoothing (PS) increases the intensity range for efficient coupling of frequency doubled (527 nm) laser light to a long scale-length plasma with n e /n cr equals 0.14 and T e equals 2 keV. (authors)

  15. A UWOC system based on a 6 m/5.2 Gbps 680 nm vertical-cavity surface-emitting laser

    Science.gov (United States)

    Li, Chung-Yi; Tsai, Wen-Shing

    2018-02-01

    This study proves that an underwater wireless optical communication (UWOC) based on a 6 m/5.2 Gbps 68 nm vertical-cavity surface-emitting laser (VCSEL)-based system is superior to a 405 nm UWOC system. This UWOC application is the first to use a VCSEL at approximately 680 nm. The experiment also proved that a 680 nm VCSEL has the same transmission distance as that of an approximately 405 nm laser diode. The 680 nm VCSEL has a 5.2 Gbps high transmission rate and can transmit up to 6 m. Thus, the setup is the best alternative solution for high-speed UWOC applications.

  16. High-frequency ultrasound evaluation of cellulite treated with the 1064 nm Nd:YAG laser.

    Science.gov (United States)

    Bousquet-Rouaud, Regine; Bazan, Marie; Chaintreuil, Jean; Echague, Agustina Vila

    2009-03-01

    To investigate non-invasive laser treatment for cellulite using the 1064 nm Nd:YAG laser and to correlate clinical results with high-frequency skin ultrasound images. Twelve individuals of normal weight were treated on either the left or right posterior side of the thigh with the following parameters: fluence 30 J/cm, 18 mm spot size and dynamic cooling device pulse duration of 30 ms. Three treatments were performed at intervals of 3-4 weeks, and followed-up 1 and 3 months after the last session. Photographs and ultrasound imaging were assessed before each session. The 1064 nm Nd:YAG laser resulted in a tightening of the skin and an improvement in cellulite. No side effects were reported. High-resolution ultrasound imaging showed a significant improvement in dermis density and a reduction of dermis thickness. The method is described in detail in Appendix 1. Infra-red lasers may constitute a safe and effective treatment for cellulite and high-frequency ultrasound imaging provides a quantitative and objective measurement of the treatment efficacy.

  17. Wavelength dependence of the single pulse femtosecond laser ablation threshold of indium phosphide in the 400-2050 nm range

    International Nuclear Information System (INIS)

    Borowiec, A.; Tiedje, H.F.; Haugen, H.K.

    2005-01-01

    We present single pulse femtosecond laser ablation threshold measurements of InP obtained by optical, scanning electron, and atomic force microscopy. The experiments were conducted with laser pulses 65-175 fs in duration, in the wavelength range from 400 to 2050 nm, covering the photon energy region above and below the bandgap of InP. The ablation thresholds determined from depth and volume measurements varied from 87 mJ/cm 2 at 400 nm to 250 mJ/cm 2 at 2050 nm. In addition, crater depths and volumes were measured over a range of laser fluences extending well above the ablation threshold

  18. Nonlinear evolution of broad-bandwidth, laser-imprinted nonuniformities in planar targets accelerated by 351-nm laser light

    International Nuclear Information System (INIS)

    Smalyuk, V.A.; Boehly, T.R.; Bradley, D.K.; Goncharov, V.N.; Delettrez, J.A.; Knauer, J.P.; Meyerhofer, D.D.; Oron, D.; Shvarts, D.; Srebro, Y.; Town, R.P.

    1999-01-01

    Planar, 20 and 40 μm thick CH targets have been accelerated by 351 nm laser beams of the OMEGA laser system [Opt. Commun. 133, 495 (1997)]. Different beam-smoothing techniques were employed including distributed phase plates, smoothing by spectral dispersion, and distributed polarization rotators. The Rayleigh - Taylor evolution of three-dimensional (3D) broadband planar-target perturbations seeded by laser nonuniformities was measured using x-ray radiography at ∼1.3 keV. Fourier analysis shows that the perturbations evolve to longer wavelengths and the shorter wavelengths saturate. The saturation amplitudes and rates of growth of these features are consistent with the predictions of Haan [Phys. Rev. A 39, 5812 (1989)]. copyright 1999 American Institute of Physics

  19. INTERACTION OF LASER RADIATION WITH MATTER. LASER PLASMA High-power EUV (13.5 nm) light source

    Science.gov (United States)

    Borisov, Vladimir M.; Borisova, Galina N.; Vinokhodov, Aleksandr Yu; Zakharov, S. V.; Ivanov, Aleksandr S.; Kiryukhin, Yurii B.; Mishchenko, Valentin A.; Prokof'ev, Aleksandr V.; Khristoforov, Oleg B.

    2010-10-01

    Characteristics of a discharge-produced plasma (DPP) light source in the spectral band 13.5±0.135 nm, developed for Extreme Ultra Violet (EUV) lithography, are presented. EUV light is generated by DPP in tin vapour formed between rotating disk electrodes. The discharge is ignited by a focused laser beam. The EUV power 1000 W/(2π sr) in the spectral band 13.5±0.135 nm was achieved with input power about of ~63 kW to the plasma at a pulse repetition rate ~7 kHz . The results of numerical simulation are compared with the experimental data.

  20. 5 nm structures produced by direct laser writing

    International Nuclear Information System (INIS)

    Pavel, E; Jinga, S; Andronescu, E; Vasile, B S; Rotiu, E; Ionescu, L; Mazilu, C

    2011-01-01

    Here we present a new approach to overcome the optical diffraction limit by using novel materials. In the paper, we report experimental results obtained by high-resolution transmission electron microscopy (HRTEM) and optical absorption spectroscopy, for a fluorescent photosensitive glass-ceramic containing rare-earth ions such as samarium (Sm). Using a home built dynamic tester, with a low power laser, we recorded nanostructures having 5 nm line widths. In the line structure, measurements reveal the presence of silver nanocrystals with few nanometre sizes. HRTEM shows that there is a random orientation of the nanocrystals. A writing mechanism with three steps is proposed.

  1. Mechanistic comparison of pulse laser induced phase separation of particulates from cellulose paper at 213 nm and 532 nm

    Energy Technology Data Exchange (ETDEWEB)

    Arif, S.; Forster, M.; Kautek, W. [University of Vienna, Department of Physical Chemistry, Wien (Austria); Bushuk, S.; Kouzmouk, A.; Tatur, H.; Batishche, S. [National Academy of Sciences of the Republic of Belarus, Institute of Physics, Minsk (Belarus)

    2013-02-15

    The laser-induced phase separation of charcoal particles on additive-free cotton linters cellulose paper was investigated by electron and optical microscopy, colorimetry, and diffuse reflectance FT-IR. The fibre bundles were vaporised in depth of several 10 {mu}m above destruction fluence thresholds using visible 532 nm radiation. This is in contrast to mid-ultraviolet 213 nm radiation, where only the top fibre bundles were modified and partially evaporated. The colorimetric lightness results generally represented the cleaning status, whereas the colorimetric yellowing data represented irreversible chemical and/or photochemical changes. Charcoal-contaminated paper treated with visible and mid-ultraviolet radiation exhibited yellowing, whereas uncontaminated did not. This suggests that the electron-rich plasma generated by the evaporation of the particles heats the adjacent substrate and also excludes oxygen. Mid-ultraviolet, in contrast to visible radiation, shows particle removal always accompanied by paper destruction. IR spectroscopy results suggest cross-linking by ether bonds near the destruction threshold, but do not prove the formation of oxidation products and double bonds as the basis of the yellowing. A ''cleaning window'' between the cleaning threshold (0.1 J/cm{sup 2}) and the paper destruction threshold (2.9 J/cm{sup 2}) with a pulse number of 2 is provided by visible 532 nm laser treatment. (orig.)

  2. Injection Characterization of Packaged Bi-Directional Diamond Shaped Ring Laser at 1550 NM

    National Research Council Canada - National Science Library

    Bussjager, Rebecca; Erdmann, Reinhard; Kovanis, Vassillios; McKeon, Brian; Fanto, Michael; Johns, Steve; Hayduk, Michael J; Osman, Joseph; Morrow, Alan; Green, Malcolm

    2006-01-01

    The Air Force Research Laboratory. Binoptics Corp. and Infotonics Technology Center worked collaboratively to package and characterize recently developed diode based ring lasers that operate at 1550 nm in a diamond shaped cavity...

  3. Influence of laser radiation on the growth and development of seeds of agricultural plants

    Science.gov (United States)

    Grishkanich, Alexander; Zhevlakov, Alexander; Polyakov, Vadim; Kascheev, Sergey; Sidorov, Igor; Ruzankina, Julia; Yakovlev, Alexey; Mak, Andrey

    2016-04-01

    The experimental results presented in this study focused on the study of biological processes caused by exposure to the coating layers of the laser green light seed (λ = 532 nm) range for the larch, violet (λ = 405 nm) and red (λ = 640 nm) for spruce. Spend a series of experiments to study the dependence of crop seed quality (spruce and larch from the pine family) from exposure to laser radiation under different conditions. In all the analyzed groups studied seed germination and growth of seedlings exposed to laser exposure, compared with the control group. The results showed that the higher percentage of germination than seeds of the control group.

  4. Surgical effects on soft tissue produced by a 405-nm violet diode laser in vivo

    Science.gov (United States)

    Miyazaki, H.; Kato, J.; Kawai, S.; Hatayama, H.; Uchida, K.; Otsuki, M.; Tagami, J.; Yokoo, S.

    2011-12-01

    This study evaluated the surgical performance of a 405-nm diode laser in vivo, using living rat liver tissue. Tissue was incised by irradiation with the laser at low output power ranging from 1 W (722 W/cm2) to 3 W (2165 W/cm2) on a manual control at a rate of 1 mm/s. As a control, incisions using a stainless scalpel were compared. Immediately after operation, the surface of the incisions was macroscopically observed and histopathologically evaluated by microscopy. Laser-ablated liver tissue was smooth with observable signs of remnant carbonization and easily acquired hemostasis. The thickness of the denatured layer increased in proportion to the output power; the coagulation layer did not thicken accordingly. Bleeding could not be stopped for tissues incised with the stainless scalpel. The 405-nm diode laser thus proved to be effective for ablating soft tissue with high hemostatic ability at low power.

  5. MOVPE growth and characterization of (In,Ga)N quantum structures for laser diodes emitting at 440 nm

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Veit

    2011-04-18

    The presented work describes the metal organic vapor phase epitaxy and characterization of nitride-based quantum structures which are used in laser heterostructures emitting in the wavelength range between 400 nm and 440 nm. Aiming at current injection and optically pumped laser structures with low threshold current or respectively threshold power densities, the device properties were correlated with the material properties of the indium gallium nitride (InGaN) active region. Furthermore, the influence of the active region and waveguide heterostructure layout on the material gain as well as the modal gain was investigated. In order to understand the InGaN growth process and the formation of structural imperfections, 15 nm-100 nm thick InGaN single layers were deposited on gallium nitride (GaN) on sapphire substrates and analyzed subsequently. It turned out that the spiral pattern of the growth edges around screw dislocations, threading from the substrate to the growth surface, and the formation of additional V-shaped surface defects are the main cause for the deterioration of the crystal perfection of the InGaN. As a result of the transition from a layer-by-layer to a 3D growth regime stable facets with preferred indium incorporation are formed that increase the lateral variation of the indium mole fraction in the layer. The higher indium incorporation at the facets is explained by dynamical elasticity theory and proven by the growth and characterization of InGaN layers on differently oriented GaN. The material properties of the InGaN quantum wells were correlated with laser device properties using 400 nm laser structures: In the case of thin quantum wells the 3D growth results in a lateral variation of the band gap due to variations of the indium mole fraction and the well width. Systematical investigations of laser structures with different band gap fluctuations show an increase of the threshold power density as the lateral variation of the band gap increases. It

  6. Wound treatment on a diabetic rat model by a 808 nm diode laser

    International Nuclear Information System (INIS)

    Lau, Pik Suan; Bidin, Noriah; Krishnan, Ganesan; AnaybBaleg, Sana Mohammed; Baktiar, Harzi; Marsin, Faridah M; Sum, Mohamad Bin Md; Nassir, Zaleha; Chong, Pek Lian; Hamid, Asmah

    2015-01-01

    This paper presents a study on the effect of laser irradiation on wound healing. 808 nm diode laser was employed to facilitate the healing of impaired wounds in experimental diabetes using a rat model. Diabetes was induced in male rats by a streptozotocin injection with a dose of 60 mg kg −1 . The disease was verified via measurement of the blood glucose level, which was set having 20 mmol L −1 stability. The rats were randomly distributed into two groups; one served as a control group and the other group was treated with the laser. The power density of the laser used was 0.5 W cm −2 and the wounds were treated for 8 d with the contact time of one second daily. The energy density used was 0.5 J cm −2 . The healing progress was recorded via a digital camera. The recorded images were then transferred into Inspector Matrox and image J programs for the accurate measurement of the healing area. The tissue details of the wound were studied through histology. The wound contraction rate of laser therapy group was found to be two times faster than control group. This indicates that the 808 nm diode laser can accelerate the wound healing process. (paper)

  7. 16.7 W 885 nm diode-side-pumped actively Q -switched Nd:YAG/YVO4 intracavity Raman laser at 1176 nm

    International Nuclear Information System (INIS)

    Jiang, Pengbo; Zhang, Guizhong; Liu, Jian; Ding, Xin; Sheng, Quan; Sun, Bing; Shi, Rui; Wu, Liang; Yao, Jianquan; Yu, Xuanyi; Wang, Rui

    2017-01-01

    We proposed and experimentally demonstrated the generation of high-power 1176 nm Stokes wave by frequency shifting of a 885 nm diode-side-pumped Nd:YAG laser using a YVO 4 crystal in a Z -shaped cavity configuration. Employing the 885 nm diode-side-pumped scheme and the Z -shaped cavity, for the first time to our knowledge, we realized the thermal management effectively, achieving excellent 1176 nm Stokes wave consequently. With an incident pump power of ∼190.0 W, a maximum average output power of 16.7 W was obtained at the pulse repetition frequency of 10 kHz. The pulse duration and spectrum linewidth of the Stokes wave at the maximum output power were 20.3 ns and ∼0.08 nm, respectively. (paper)

  8. LD-pumped Nd:YVO sub 4 frequency-doubled by CPM LBO laser at 671 nm

    CERN Document Server

    Zheng Quan; Qian Long Sheng; Zhao Ling

    2001-01-01

    A design of LD-pumped high efficient Nd:YVO sub 4 /LBO red laser is reported. Using critical phase-matching LBO for the first time, 671 nm red laser is obtained by 1.342 mu m intracavity frequency doubling. With 800 mW incident pump laser, 52 mW and 97 mW TEM00 mode red laser output are obtained by II-typed and I-typed LBO. The optical-to-optical conversions are up to 6.5% and 12.1% respectively

  9. Generation of continuous-wave single-frequency 1.5 W 378 nm radiation by frequency doubling of a Ti:sapphire laser.

    Science.gov (United States)

    Cha, Yong-Ho; Ko, Kwang-Hoon; Lim, Gwon; Han, Jae-Min; Park, Hyun-Min; Kim, Taek-Soo; Jeong, Do-Young

    2010-03-20

    We have generated continuous-wave single-frequency 1.5 W 378 nm radiation by frequency doubling a high-power Ti:sapphire laser in an external enhancement cavity. An LBO crystal that is Brewster-cut and antireflection coated on both ends is used for a long-term stable frequency doubling. By optimizing the input coupler's reflectivity, we could generate 1.5 W 378 nm radiation from a 5 W 756 nm Ti:sapphire laser. According to our knowledge, this is the highest CW frequency-doubled power of a Ti:sapphire laser.

  10. Detection and Analytical Capabilities for Trace Level of Carbon in High-Purity Metals by Laser-Induced Breakdown Spectroscopy with a Frequency Quintupled 213 nm Nd:YAG Laser

    Directory of Open Access Journals (Sweden)

    Masaki Ohata

    2017-01-01

    Full Text Available The laser-induced breakdown spectroscopy (LIBS with a frequency quintupled 213 nm Nd:YAG laser was examined to the analysis of trace level of carbon (C in high-purity metals and its detection and analytical capabilities were evaluated. Though C signal in a wavelength of 247.9 nm, which showed the highest sensitivity of C, could be obtained from Cd, Ti, and Zn ca. 7000 mg kg−1 C in Fe could not be detected due to the interferences from a lot of Fe spectra. Alternative C signal in a wavelength of 193.1 nm could not be also detected from Fe due to the insufficient laser output energy of the frequency quintupled 213 nm Nd:YAG laser. The depth analysis of C by LIBS was also demonstrated and the C in Cd and Zn was found to be contaminated in only surface area whereas the C in Ti was distributed in bulk. From these results, the frequency quintupled 213 nm Nd:YAG laser, which was adopted widely as a commercial laser ablation (LA system coupled with inductively coupled plasma mass spectrometry (ICPMS for trace element analysis in solid materials, could be used for C analysis to achieve simultaneous measurements for both C and trace elements in metals by LIBS and LA-ICPMS, respectively.

  11. 1064-nm Nd:YAG and 980-nm Diode Laser EDTA Agitation on the Retention of an Epoxy-Based Sealer to Root Dentin.

    Science.gov (United States)

    Macedo, Helena Suleiman de; Messias, Danielle Cristine Furtado; Rached-Júnior, Fuad Jacob; Oliveira, Ligia Teixeira de; Silva-Sousa, Yara Teresinha Correa; Raucci-Neto, Walter

    2016-01-01

    Root canal irrigants are used to minimize the negative effects of smear layer on endodontic sealer retention. The aim of this study was to evaluate the efficacy of agitation of 17% ethylenediaminetetraacetic acid (EDTA) with ultrasonic, 1064-nm Nd:YAG and 980-nm diode laser on the retention of an epoxy-based sealer to the root canal walls. Forty single-rooted bovine teeth were instrumented with ProTaper rotary system and divided into four groups according to the final irrigation protocol (n = 10): (1) 17% EDTA (control); (2) 17% EDTA with 50-s ultrasonic agitation; (3) 17% EDTA with 50-s diode laser (2-W) agitation; and (4) 17% EDTA with 50-s Nd:YAG (1.5-W) laser agitation. After endodontic filling with gutta-percha F5 master cone and Sealer 26, the roots were sectioned at the cervical, middle, and apical root thirds to obtain 1.5-mm slices. Push-out tests were performed using a universal testing machine at a 1 mm/min crosshead speed. Data were analyzed using two-way ANOVA and Tukey's tests (α=0.05). Apical root thirds had significant higher retention values than cervical and middle thirds (p diode laser presented the highest retention values and was significantly different from EDTA with ultrasonic agitation and EDTA only (p diode laser EDTA agitation enhanced the retention of the epoxy-based sealer to the root canal walls compared with that due to EDTA only or EDTA with ultrasonic agitation.

  12. Infrared laser sealing of porcine vascular tissues using a 1,470 nm diode laser: Preliminary in vivo studies.

    Science.gov (United States)

    Cilip, Christopher M; Kerr, Duane; Latimer, Cassandra A; Rosenbury, Sarah B; Giglio, Nicholas C; Hutchens, Thomas C; Nau, William H; Fried, Nathaniel M

    2017-04-01

    Infrared (IR) lasers are being explored as an alternative to radiofrequency (RF) and ultrasonic (US) devices for rapid hemostasis with minimal collateral zones of thermal damage and tissue necrosis. Previously, a 1,470 nm IR laser sealed and cut ex vivo porcine renal arteries of 1-8 mm diameter in 2 seconds, yielding burst pressures greater than 1,200 mmHg and thermal coagulation zones less than 3 mm. This preliminary study describes in vivo testing of a handheld laser probe in a porcine model. A handheld prototype with vessel/tissue clasping mechanism was tested on 73 blood vessels less than 6 mm diameter using 1,470 nm laser power of 35 W for 1-5 seconds. Device power settings, irradiation time, tissue type, vessel diameter, and histology sample number were recorded for each procedure. The probe was evaluated for hemostasis after sealing isolated and bundled arteriole/venous (A/V) vasculature of porcine abdomen and hind leg. Sealed vessel samples were collected for histological analysis of lateral thermal damage. Hemostasis was achieved in 57 of 73 seals (78%). The probe consistently sealed vasculature in small bowel mesentery, mesometrium, and gastrosplenic and epiploic regions. Seal performance was less consistent on hind leg vasculature including saphenous arteries/bundles and femoral and iliac arteries. Collagen denaturation averaged 1.6 ± 0.9 mm in eight samples excised for histologic examination. A handheld laser probe sealed porcine vessels, in vivo. Further probe development and laser parameter optimization is necessary before infrared lasers may be evaluated as an alternative to RF and US vessel sealing devices. Lasers Surg. Med. 49:366-371, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Photobiostimulation effects on germination and early growth of wheat seeds (Triticum aestivum L) produced by a semiconductor laser with λ=980nm

    International Nuclear Information System (INIS)

    Michtchenko, A.; Hernandez, M.

    2009-01-01

    The effect of the exposure of wheat (Triticum aestivum L) seeds to a IR laser radiation with λ=980nm produced by a semiconductor laser on germination and early growth had been studied under laboratory conditions. Seeds were irradiated to one of two laser intensities 15 mWcm - ''2 or 30 mWcm -2 for different periods of time 30, 60 or 120 s. Seeds exposed to a light intensity of 15mWcm -2 and an exposition time of 30 s. showed an increase on the percentage of seeds germinated normally while the percentage of seeds germinated abnormally decreased. At the same time there is a stimulation effect on the growth of the stem and on the growth of the root of 10% on wheat seedlings over control seedlings. Significant differences (ρ < 0.001) were observed between the control and the above treatment. (Author)

  14. Current treatments of acne: Medications, lights, lasers, and a novel 650-μs 1064-nm Nd: YAG laser.

    Science.gov (United States)

    Gold, Michael H; Goldberg, David J; Nestor, Mark S

    2017-09-01

    The treatment of acne, especially severe acne, remains a challenge to dermatologists. Therapies include retinoids, antibiotics, hormones, lights, lasers, and various combinations of these modalities. Acne is currently considered a chronic rather than an adolescent condition. The appropriate treatment depends on the patient and the severity of disease. The purpose of this study was to review current therapies for acne of all severities and to introduce the 650-μs 1064-nm laser for the treatment of acne. © 2017 Wiley Periodicals, Inc.

  15. Diode lasers with asymmetric barriers for 850 nm spectral range: experimental studies of power characteristics

    DEFF Research Database (Denmark)

    Zubov, F. I.; Zhukov, A. E.; Shernyakov, Yu M.

    2015-01-01

    It is demonstrated that the use of asymmetric barrier layers in a waveguide of a diode laser suppress non-linearity of light-current characteristic and thus improve its power characteristics under high current injection. The results are presented for 850-nm AlGaAs/GaAs broad-area lasers with Ga...

  16. Sub-1100 nm lasing from post-growth intermixed InAs/GaAs quantum-dot lasers

    KAUST Repository

    Alhashim, Hala H.

    2015-08-15

    Impurity free vacancy disordering induced highly intermixed InAs/GaAs quantum-dot lasers are reported with high internal quantum efficiency (>89%). The lasers are shown to retain the device characteristics after intermixing and emitting in the important wavelength of ∼1070–1190 nm. The non-coated facet Fabry-Pērot post-growth wavelength tuned lasers exhibits high-power (>1.4W) and high-gain (∼50 cm −1), suitable for applications in frequency doubled green–yellow–orange laser realisation, gas sensing, metrology etc.

  17. Effects of a 1,450 nm diode laser on facial sebum excretion.

    Science.gov (United States)

    Laubach, Hans-Joachim; Astner, Susanne; Watanabe, Kanna; Clifford, Joan; Rius-Diaz, Francisca; Zurakowski, David; Manstein, Dieter

    2009-02-01

    Laser therapy with a 1,450 nm diode laser is a clinically effective treatment for acne vulgaris, although the mechanism of action is unknown. To investigate this, we conducted a small, prospective, controlled clinical trial to assess this laser's effects on the facial sebum excretion rate (SER). Fourteen healthy volunteers without active acne were enrolled in this study and received three laser treatments on test areas of the nose and forehead. Nine subjects completed the treatment regimen and were available for follow-up. SER was measured with Sebumeter prior to the first treatment, and at 1 week and 1 month after the third treatment. Photographs were taken and subjective assessment of skin oiliness and pore size determined by questionnaires at 1 month follow-up. No significant reduction in SER was observed comparing treated with control on all treatment sites (P>0.05) on the nose. Reduction in the absolute SER was observed for both test and control sites on the forehead, reaching significance on the treatment site (P = 0.04) and marginal significance on the control site (P = 0.08). While our study was designed to detect only large changes in SER, we conclude that three 1,450 nm laser treatment sessions did not cause marked changes in SER compared to the control (i.e., >44%). Thus, major destruction of sebaceous glands as a result of this treatment is unlikely. However, reduced sebum production was observed on both treatment and control sides at 1 month. Therefore alternative mechanisms should also be considered to explain the clinical efficacy of this treatment for acne vulgaris. (c) 2009 Wiley-Liss, Inc.

  18. Skin color and tissue thickness effects on transmittance, reflectance, and skin temperature when using 635 and 808 nm lasers in low intensity therapeutics.

    Science.gov (United States)

    Souza-Barros, Leanna; Dhaidan, Ghaith; Maunula, Mikko; Solomon, Vaeda; Gabison, Sharon; Lilge, Lothar; Nussbaum, Ethne L

    2018-04-01

    To examine the role of skin color and tissue thickness on transmittance, reflectance, and skin heating using red and infrared laser light. Forty volunteers were measured for skin color and skin-fold thickness at a standardized site near the elbow. Transmittance, reflectance and skin temperature were recorded for energy doses of 2, 6, 9, and 12 Joules using 635 nm (36 mW) and 808 nm (40 mW) wavelength laser diodes with irradiances within American National Standards Institute safety guidelines (4.88 mm diameter, 0.192 W/cm 2 and 4.88 mm diameter, 0.214 W/cm 2 , respectively). The key factors affecting reflectance to an important degree were skin color and wavelength. However, the skin color effects were different for the two wavelengths: reflectance decreased for darker skin with a greater decrease for red light than near infrared light. Transmittance was greater using 808 nm compared with 635 nm. However, the effect was partly lost when the skin was dark rather than light, and was increasingly lost as tissue thickness increased. Dose had an increasing effect on temperature (0.7-1.6°C across the 6, 9, and 12 J doses); any effects of wavelength, skin color, and tissue thickness were insignificant compared to dose effects. Subjects themselves were not aware of the increased skin temperature. Transmittance and reflectance changes as a function of energy were very small and likely of no clinical significance. Absorption did not change with higher energy doses and increasing temperature. Skin color and skin thickness affect transmittance and reflectance of laser light and must be accounted for when selecting energy dose to ensure therapeutic effectiveness at the target tissue. Skin heating appears not to be a concern when using 635 and 808 nm lasers at energy doses of up to 12 J and irradiance within American National Standards Institute standards. Photobiomodulation therapy should never exceed the American National Standards Institute

  19. The effect of a 1550 nm fractional erbium-glass laser in female pattern hair loss.

    Science.gov (United States)

    Lee, G-Y; Lee, S-J; Kim, W-S

    2011-12-01

    Female pattern hair loss (FPHL) is the most common cause of hair loss in women, and its prevalence increases with advancing age. Affected women may experience psychological distress and social withdrawal. A variety of laser and light sources have been tried for treatment of hair loss, and some success has been reported. The purpose of this study was to determine the efficacy and safety of a 1550 nm fractional erbium-glass laser in treatment of female pattern hair loss. Twenty eight ethnic South Korean patients with varying degrees of FPHL were enrolled in the study. Patients received ten treatments with a 1550 nm fractional Er:Glass Laser (Mosaic, Lutronic Co., Ltd, Seoul, South Korea) at 2-weeks intervals using the same parameters (5-10 mm tip, 6 mJ pulse energy, 800 spot/cm(2) density, static mode). Phototrichogram and global photographs were taken at baseline and at the end of laser treatment, and analysed for changes in hair density and hair shaft diameter. Global photographs underwent blinded review by three independent dermatologists using a 7-point scale. Patients also answered questionnaires assessing hair growth throughout the study. All adverse effects were reported during the study. Twenty seven patients completed a 5-month schedule of laser treatment. One patient was excluded during treatment due to occurrence of alopecia areata. At the initial visit, mean hair density was 100 ± 14/cm(2) , and mean hair thickness was 58 ± 12 μm. After 5 months of laser treatment, hair density showed a marked increase to 157 ± 28/cm(2) (P laser treatment; however, these resolved within 2 h. A 1550 nm fractional erbium-glass laser irradiation may be an effective and safe treatment option for women with female pattern hair loss. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.

  20. Picosecond 532-nm neodymium-doped yttrium aluminum garnet laser-a promising modality for the management of verrucous epidermal nevi.

    Science.gov (United States)

    Levi, Assi; Amitai, Dan Ben; Mimouni, Daniel; Leshem, Yael A; Arzi, Ofir; Lapidoth, Moshe

    2018-04-01

    The verrucous epidermal nevus (VEN) is the most common type of epidermal nevi. As lesions can be disfiguring, treatment is often sought. Many therapeutic approaches have been reported, with variable efficacy and safety. Picosecond (PS) lasers are novel laser devices designated to target small chromophores. A side effect of these lasers is blistering due to epidermal-dermal separation. We aimed to harness this side effect of the PS lasers to treat patients with VEN. The purpose of this study was to report our experience treating VEN using a PS 532-nm laser. We present a retrospective case series of six patients with large VEN who were treated using a PS 532-nm laser (2-6 treatments, 8-10 weeks apart). Response in clinical photographs was assessed by two independent dermatologists and graded on a scale of 0 (exacerbation) to 4 (76-100% improvement). Patient satisfaction was recorded on a scale of 1-5. All patients demonstrated significant improvement. Average improvement was 3.7 on the quartile scale of improvement. Patient satisfaction rate averaged 4.7. The PS 532-nm laser is a promising novel modality for the treatment of large VEN.

  1. Modification of genetic effects of gamma radiation by laser radiation

    International Nuclear Information System (INIS)

    Khotyljova, L.V.; Khokhlova, S.A.; Khokhlov, I.V.

    1988-01-01

    Full text: Mutants obtained by means of ionizing radiation and chemical mutagens often show low viability and productivity that makes their use in plant breeding difficult. Methods reducing the destructive mutagen action on important functions of plant organism and increasing quality and practical value of induced mutants would be interesting. We believe that one method for increasing efficiency of experimental mutagenesis in plants is the application of laser radiation as a modificator of genetic effects of ionizing radiation and chemical mutagens. Combined exposure of wheat seedlings to a gamma radiation dose of 2 kR and to laser radiation with the wave length of 632.8 nm (power density - 20 mVt/cm 2 , exposure - 30 min.) resulted in reducing the chromosomal aberration percentage from 30.5% in the gamma version to 16.3% in the combined treatment version. A radiosensibilizing effect was observed at additional exposure of gamma irradiated wheat seeds to laser light with the wave length of 441.6 nm where chromosomal aberration percentage increased from 22% in the gamma-irradiation version to 31% in the combined treatment version. By laser radiation it is also possible to normalize mitotic cell activity suppressed by gamma irradiation. Additional seedling irradiation with the light of helium-neon laser (632.8 nm) resulted in recovery of mitotic cell activity from 21% to 62% and increasing the average content of DNA per nucleus by 10%. The influence of only laser radiation on plant variability was also studied and it was shown that irradiation of wheat seeds and seedlings with pulsed and continuous laser light of visible spectrum resulted in phenotypically altered forms in M 2 . Their frequencies was dependent upon power density, dose and radiation wave length. Number of altered forms increased in going from long-wave to short-wave spectrum region. In comparing efficiency of different laser types of pulsed and continuous exposure (dose - 180 J/cm 2 ) 2% of altered

  2. 700 W blue fiber-coupled diode-laser emitting at 450 nm

    Science.gov (United States)

    Balck, A.; Baumann, M.; Malchus, J.; Chacko, R. V.; Marfels, S.; Witte, U.; Dinakaran, D.; Ocylok, S.; Weinbach, M.; Bachert, C.; Kösters, A.; Krause, V.; König, H.; Lell, A.; Stojetz, B.; Löffler, A.; Strauss, U.

    2018-02-01

    A high-power blue laser source was long-awaited for processing materials with low absorption in the near infrared (NIR) spectral range like copper or gold. Due to the huge progress of GaN-based semiconductors, the performance of blue diode-lasers has made a major step forward recently. With the availability of unprecedented power levels at cw-operating blue diode-lasers emitting at 450 nm, it was possible to set up a high-power diode-laser in the blue spectral range to address these conventional laser applications and probably beyond that to establish completely new utilizations for lasers. Within the scope of the research project "BlauLas", funded within the German photonic initiative "EFFILAS" [8] by the German Federal Ministry of Education and Research (BMBF), Laserline in cooperation with OSRAM aims to realize a cw fiber-coupled diode-laser exceeding 1 kW blue laser power. In this paper the conceptual design and experimental results of a 700 W blue fiber-coupled diode-laser are presented. Initially a close look had to be taken on the mounting techniques of the semiconductors to serve the requirements of the GaN laser diodes. Early samples were used for extensive long term tests to investigate degradation processes. With first functional laser-modules we set up fiber-coupled laser-systems for further testing. Besides adaption of well-known optical concepts a main task within the development of the laser system was the selection and examination of suitable materials and assembling in order to minimize degradation and reach adequate lifetimes. We realized R&D blue lasersystems with lifetimes above 5,000 h, which enable first application experiments on processing of various materials as well as experiments on conversion to white-light.

  3. CW light sources at the 589 nm sodium D2 line by sum-frequency mixing of diode pumped neodymium lasers

    International Nuclear Information System (INIS)

    Lü, Y F; Lu, J; Xu, L J; Sun, G C; Zhao, Z M; Gao, X; Lin, J Q

    2010-01-01

    We present a laser architecture to obtain continuous-wave (CW) light sources at the 589 nm sodium D2 line. A 808 nm diode-pumped a Nd:YLiF 4 (Nd:YLF) crystal emitting at 1053 nm. A part of the pump power was then absorbed by the Nd:YLF crystal. The remaining was used to pump a Nd:YAG crystal emitting at 1338 nm. Intracavity sum-frequency mixing at 1053 and 1338 nm was then realized in a LiB 3 O 5 (LBO) crystal to reach the yellow-orange radiation. We obtained a CW output power of 235 mW at 589 nm with a pump laser diode emitting 17.8 W at 808 nm

  4. Pulsed Er:YAG- and 308 nm UV-excimer laser: an in vitro and in vivo study of skin-ablative effects

    Energy Technology Data Exchange (ETDEWEB)

    Kaufmann, R.; Hibst, R.

    1989-01-01

    Using a pulsed XeCl excimer laser (308 nm) and a pulsed Er:YAG laser (2,940 nm), we investigated skin ablation as a function of pulse number, radiant energy, and repetition rate. In vitro analysis of lesions performed in freshly excised human skin were consistent with in vivo results obtained from experiments on pig skin. Pulsed 308 nm laser radiation caused considerable nonspecific thermal tissue injury followed by an inflammatory reaction and impaired healing of lesions in vivo. These findings were especially pronounced with higher repetition rates, which would be required for efficient destruction of larger lesions. On the other hand, the 2.94 microns Er:YAG laser radiation produced clean and precise lesions with only minimal adjacent injury. In vivo skin ablation caused intraoperative bleeding with deeper penetration. The Er:YAG laser offers a promising surgical tool for careful removal of superficial epidermal lesions, if higher repetition rates, and an appropriate laser beam delivery system are available for clinical use.

  5. Diode laser in-band pumped, efficient 1645 nm continuous-wave and Q-switched Er:YLuAG lasers with near-diffraction-limited beam quality

    International Nuclear Information System (INIS)

    Li, Jing; Yang, SuHui; He, Tao

    2014-01-01

    Fiber-like Er:YLuAG laser rods were tested for continuous-wave (CW) and Q-switched operation. Two narrow-band laser diodes emitting at 1532 nm were used as pump sources. The pump power was confined in the laser rods via total internal reflection. In CW mode, a maximum output power of 7.2 W was measured from a 30 mm long Er:YLuAG laser rod, corresponding to an optical–optical efficiency of 26% and a slope efficiency of 78%. Er:YLuAG and Er:YAG lasers were compared experimentally and exhibited comparable performance, while the measured central wavelength of the Er:YLuAG laser was 1644.75 nm, slightly longer than the central wavelength of the Er:YAG laser in the same experimental circumstances. In Q-switched mode, an output energy of 3.5 mJ was obtained from a 25 mm Er:YLuAG laser rod with a pulse duration of 100 ns and a pulse repetition frequency of 100 Hz. The pulsed output had near-diffraction-limited beam quality with M 2 values of 1.13 and 1.11 in the x and y directions, respectively. (letter)

  6. Pulsed laser deposition of aluminum-doped ZnO films at 355 nm

    DEFF Research Database (Denmark)

    Holmelund, E.; Schou, Jørgen; Thestrup Nielsen, Birgitte

    2004-01-01

    Conducting, transparent films of aluminium-doped ZnO (AZO) have been produced at the laser wavelength 355 nm. The most critical property, the electric resistivity, is up to a factor of 8 above that for films produced at shorter wavelengths. In contrast, the transmission of visible light through...

  7. Fractional nonablative 1,540-nm laser resurfacing of atrophic acne scars. A randomized controlled trial with blinded response evaluation

    DEFF Research Database (Denmark)

    Hedelund, Lene; Moreau, Karen Estell R; Beyer, Ditte M

    2010-01-01

    as moderately or significantly improved. No differences were found in skin redness or pigmentation between before and after treatment. Patients experienced moderate pain, erythema, oedema, bullae, and crusts. No adverse effects were seen in untreated control areas. The nonablative 1,540-nm fractional laser......The efficacy of nonablative fractional laser resurfacing of acne scars has been described in case reports and uncontrolled trials. The present study is the first randomized controlled trial in this field. The aim of this study was to examine the efficacy and adverse effects of 1,540-nm nonablative...... fractional laser treatment of acne scars. Ten patients with acne scars were included. Two intraindividual areas of similar size and appearance within contralateral anatomical regions were randomized to (1) 3-monthly laser treatments with a StarLux 1,540-nm fractional handpiece, and (2) no treatment. Blinded...

  8. High fluence deposition of polyethylene glycol films at 1064 nm by matrix assisted pulsed laser evaporation (MAPLE)

    DEFF Research Database (Denmark)

    Purice, Andreea; Schou, Jørgen; Kingshott, P.

    2007-01-01

    Matrix assisted pulsed laser evaporation (MAPLE) has been applied for deposition of thin polyethylene glycol (PEG) films with infrared laser light at 1064 nm. We have irradiated frozen targets (of 1 wt.% PEG dissolved in water) and measured the deposition rate in situ with a quartz crystal 2...... microbalance. The laser fluence needed to produce PEG films turned out to be unexpectedly high with a threshold of 9 J/cm(2) and the deposition rate was much lower than that with laser light at 355 nm. Results from matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI......-TOF-MS) analysis demonstrate that the chemistry, molecular weight and polydispersity of the PEG films were identical to the starting material. Studies of the film surface with scanning electron microscopy (SEM) indicate that the Si-substrate is covered by a relatively homogenous PEG film with few bare spots. (c...

  9. 532 nm continuous wave mode-locked Nd:GdVO4 laser with SESAM

    International Nuclear Information System (INIS)

    Li, L; Liu, J; Liu, M; Liu, S; Chen, F; Wang, W; Wang, Y

    2009-01-01

    We obtain continuous wave mode-locked Nd:GdVO 4 -KTP laser with a SESAM. This is the first report of CW mode-locked Nd:GdVO 4 -KTP laser with a SESAM to our knowledge. 396 mw CW mode-locked pulse is achieved at the incident power of 7.653 W, with the repetition about 95 MHz. The pulse duration is assumed to be 5.5 ps, this is the shortest green pulse of 532 nm with SESAM

  10. 3.5 W of diffraction-limited green light at 515 nm from SHG of a single-frequency tapered diode laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Hansen, Anders Kragh; Müller, André

    2017-01-01

    Multi-Watt efficient compact green laser sources are required for a number of applications e.g. within biophotonics, laser pumping and laser displays. We present generation of 3.5 W of diffraction-limited green light at 515 nm by second harmonic generation (SHG) of a tapered diode laser, itself...... yielding more than 9 W at 1030 nm. SHG is performed in single pass through a cascade of two nonlinear crystals with re-focusing and dispersion compensating optics between the two nonlinear crystals. The laser is single-frequency and the output power is stabilized to better than ±0.4%....

  11. Study on biological effect on mice and use safety of 830 nm semiconductor laser

    International Nuclear Information System (INIS)

    Li Keqiu; Li Jian; Miao Xuhong; Liu Shujuan; Li Guang

    2006-01-01

    Objective: To study biological effect on mice by 830 nm semiconductor laser in different dosage, and determine the optimal irradiating dosage by observing and analyzing the immunoregulation and cytogenetical damage of mice after irradiation. Methods: The spleen and thymus areas of Kunming mice were irradiated in vitro by 830 nm semiconductor laser of 30 mW for 5 min, 10 min and 20 min per day respectively, then the blood samples were collected from orbital vein. Further, the spleen tissue and sternum marrow were collected soon after the mice were killed. Afterwards, IgG, dopamine, serotonin in serum were detected respectively. Besides these, the rate of lymphocyte transformation and the rate of micronuclei in marrow polychromatic erythrocytes were also determined. Results: With the extending of irradiating time, the detected factors changed differently. Statistically, there were differences in IgG concentration and the rate of lymphocyte transformation between 10 min group, 20 min group and control group respectively, but no difference between each experimental group were found. /compare with control group, serotonin concentration in 10 min group increased, and there was statistical difference between these two groups, while there was no difference in dopamine concentration among each group. Besides these, the rate of micronuclei in 20 min group increased. Conclusion: In this study, irradiation by semiconductor laser for appropriate time can improve immuno function of mice, but irradiation in high dosage will result in the damage of genetic material. The optimal time of irradiation by 830 nm semiconductor laser was 10 min. (authors)

  12. 5.7  W cw single-frequency laser at 671  nm by single-pass second harmonic generation of a 17.2  W injection-locked 1342  nm Nd : YVO4 ring laser using periodically poled MgO : LiNbO3.

    Science.gov (United States)

    Koch, Peter; Ruebel, Felix; Bartschke, Juergen; L'huillier, Johannes A

    2015-11-20

    We demonstrate a continuous wave single-frequency laser at 671.1 nm based on a high-power 888 nm pumped Nd:YVO4 ring laser at 1342.2 nm. Unidirectional operation of the fundamental ring laser is achieved with the injection-locking technique. A Nd:YVO4 microchip laser serves as the injecting seed source, providing a tunable single-frequency power of up to 40 mW. The ring laser emits a single-frequency power of 17.2 W with a Gaussian beam profile and a beam propagation factor of M2beam profile and a beam propagation factor of M2lasers. This work opens possibilities in cold atoms experiments with lithium, allowing the use of larger ensembles in magneto-optical traps or higher diffraction orders in atomic beam interferometers.

  13. Laser-Induced Damage Growth on Larger-Aperture Fused Silica Optical Components at 351 nm

    International Nuclear Information System (INIS)

    Wan-Qing, Huang; Wei, Han; Fang, Wang; Yong, Xiang; Fu-Quan, Li; Bin, Feng; Feng, Jing; Xiao-Feng, Wei; Wan-Guo, Zheng; Xiao-Min, Zhang

    2009-01-01

    Laser-induced damage is a key lifetime limiter for optics in high-power laser facility. Damage initiation and growth under 351 nm high-fluence laser irradiation are observed on larger-aperture fused silica optics. The input surface of one fused silica component is damaged most severely and an explanation is presented. Obscurations and the area of a scratch on it are found to grow exponentially with the shot number. The area of damage site grows linearly. Micrographs of damage sites support the micro-explosion damage model which could be used to qualitatively explain the phenomena

  14. Bragg grating photo-inscription in doped microstructured polymer optical fiber by 400 nm femtosecond laser pulses

    DEFF Research Database (Denmark)

    Hu, X.; Woyessa, Getinet; Kinet, D.

    2016-01-01

    In this paper, we report the manufacturing of high-quality endlessly single-mode doped microstructured poly(methyl methacrylate) (PMMA) optical fibers. Bragg gratings are photo-inscribed in such fibers by means of 400 nm femtosecond laser pulses through a 1060-nm-period uniform phase mask...

  15. Black phosphorus saturable absorber for Q-switched Er:YAG laser at 1645 nm

    Science.gov (United States)

    Guo, Lei; Li, Tao; Zhang, Shuaiyi; Wang, Mingjian; Yang, Kejian; Fan, Mingqi; Zhao, Shengzhi; Li, Ming

    2018-03-01

    A Q-switched Er:YAG solid-state laser at 1645 nm based on black phosphorus (BP) saturable absorbers (SAs) was demonstrated firstly to our knowledge. The BP-SA was fabricated by drop-casting BP nanoplatelets dispersion on a YAG substrate and corresponding saturable absorption properties were characterized at 1.6 μm. By employing as-prepared BP-SAs, stable Q-switched laser operations were achieved with a pulse width of 2.8 μs and a repetition rate of 34 kHz, corresponding to the average output power of 0.33 W. The results verify that BP-SAs have great potential for pulsed 1.6 μm lasers.

  16. Semiconductor-based narrow-line and high-brilliance 193-nm laser system for industrial applications

    Science.gov (United States)

    Opalevs, D.; Scholz, M.; Stuhler, J.; Gilfert, C.; Liu, L. J.; Wang, X. Y.; Vetter, A.; Kirner, R.; Scharf, T.; Noell, W.; Rockstuhl, C.; Li, R. K.; Chen, C. T.; Voelkel, R.; Leisching, P.

    2018-02-01

    We present a novel industrial-grade prototype version of a continuous-wave 193 nm laser system entirely based on solid state pump laser technology. Deep-ultraviolet emission is realized by frequency-quadrupling an amplified diode laser and up to 20 mW of optical power were generated using the nonlinear crystal KBBF. We demonstrate the lifetime of the laser system for different output power levels and environmental conditions. The high stability of our setup was proven in > 500 h measurements on a single spot, a crystal shifter multiplies the lifetime to match industrial requirements. This laser improves the relative intensity noise, brilliance, wall-plug efficiency and maintenance cost significantly. We discuss first lithographic experiments making use of this improvement in photon efficiency.

  17. Visible-to-visible four-photon ultrahigh resolution microscopic imaging with 730-nm diode laser excited nanocrystals.

    Science.gov (United States)

    Wang, Baoju; Zhan, Qiuqiang; Zhao, Yuxiang; Wu, Ruitao; Liu, Jing; He, Sailing

    2016-01-25

    Further development of multiphoton microscopic imaging is confronted with a number of limitations, including high-cost, high complexity and relatively low spatial resolution due to the long excitation wavelength. To overcome these problems, for the first time, we propose visible-to-visible four-photon ultrahigh resolution microscopic imaging by using a common cost-effective 730-nm laser diode to excite the prepared Nd(3+)-sensitized upconversion nanoparticles (Nd(3+)-UCNPs). An ordinary multiphoton scanning microscope system was built using a visible CW diode laser and the lateral imaging resolution as high as 161-nm was achieved via the four-photon upconversion process. The demonstrated large saturation excitation power for Nd(3+)-UCNPs would be more practical and facilitate the four-photon imaging in the application. A sample with fine structure was imaged to demonstrate the advantages of visible-to-visible four-photon ultrahigh resolution microscopic imaging with 730-nm diode laser excited nanocrystals. Combining the uniqueness of UCNPs, the proposed visible-to-visible four-photon imaging would be highly promising and attractive in the field of multiphoton imaging.

  18. F2 excimer laser (157 nm) radiation modification and surface ablation of PHEMA hydrogels and the effects on bioactivity: Surface attachment and proliferation of human corneal epithelial cells

    International Nuclear Information System (INIS)

    Zainuddin; Chirila, Traian V.; Barnard, Zeke; Watson, Gregory S.; Toh, Chiong; Blakey, Idriss; Whittaker, Andrew K.; Hill, David J.T.

    2011-01-01

    Physical and chemical changes at the surface of poly(2-hydroxyethyl methacrylate) (PHEMA) hydrogels modified by ablation with an F 2 excimer laser were investigated experimentally. An important observation was that only the outer exposed surface layers of the hydrogel were affected by the exposure to 157 nm radiation. The effect of the surface changes on the tendency of cells to adhere to the PHEMA was also investigated. A 0.5 cm 2 area of the hydrogel surfaces was exposed to laser irradiation at 157 nm to fluences of 0.8 and 4 J cm -2 . The changes in surface topography were analysed by light microscopy and atomic force microscopy, while the surface chemistry was characterized by attenuated total reflection infrared and X-ray photoelectron spectroscopies. Cell-interfacial interactions were examined based on the proliferation of human corneal limbal epithelial (HLE) cells cultured on the laser-modified hydrogels, and on the unexposed hydrogels and tissue culture plastic for comparison. It was observed that the surface topography of laser-exposed hydrogels showed rippled patterns with a surface roughness increasing at the higher exposure dose. The changes in surface chemistry were affected not only by an indirect effect of hydrogen and hydroxyl radicals, formed by water photolysis, on the PHEMA, but also by the direct action of laser radiation on PHEMA if the surface layers of the gel become depleted of water. The laser treatment led to a change in the surface characteristics, with a lower concentration of ester side-chains and the formation of new oxygenated species at the surface. The surface also became more hydrophobic. Most importantly, the surface chemistry and the newly created surface topographical features were able to improve the attachment, spreading and growth of HLE cells.

  19. Diode-pumped quasi-three-level Nd:GdV O4–Nd:YAG sum-frequency laser at 464 nm

    International Nuclear Information System (INIS)

    Lu, Jie

    2014-01-01

    We report a laser architecture to obtain continuous-wave (cw) blue radiation at 464 nm. A 808 nm diode pumped a Nd:GdV O 4 crystal emitting at 912 nm. A part of the pump power was then absorbed by the Nd:GdV O 4 crystal. The remainder was used to pump a Nd:YAG crystal emitting at 946 nm. Intracavity sum-frequency mixing at 912 and 946 nm was then realized in a LiB 3 O 5 (LBO) crystal to produce blue radiation. We obtained a cw output power of 1.52 W at 464 nm with a pump laser diode emitting 18.4 W at 808 nm. (letter)

  20. Emission spectrum and relaxation kinetics of SO2 induced by 266 nm laser.

    Science.gov (United States)

    Zhang, Guiyin; Zhang, Lianshui; Jin, Yidong

    2010-09-15

    Laser induced fluorescence (LIF) emission spectrum of SO(2) in the range of 270.0-470.0 nm has been obtained with the quadruple harmonic output (266 nm) of a pulsed Nd:YAG laser as excitation source. The spectrum is composed of a continuous envelope in the short wavelength side, while it shows the character of banded structure superimposed on a continuous one in the long wavelength region. Fluorescence emission from the hybrid states of A(1)A(2)+B(1)B(1) and X(1)A(1)+B(1)B(1) forms the continuous envelope and phosphorescence emission from the triplet state a(3)B(1) forms the banded progression. It is also found that direct emission from laser excited states is very weak. The primary portion of the emission is from the energy levels populated by collision relaxation or collision induced intersystem crossing process. The harmonic frequencies and inharmonic coefficients of the symmetric stretching vibration and the bending vibration of X(1)A(1) state are derived from the ascription of the phosphorescence progression. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Toward Ultraintense Compact RBS Pump for Recombination 3.4 nm Laser via OFI

    Science.gov (United States)

    Suckewer, S.; Ren, J.; Li, S.; Lou, Y.; Morozov, A.; Turnbull, D.; Avitzour, Y.

    In our presentation we overview progress we made in developing a new ultrashort and ultraintensive laser system based on Raman backscattering (RBS) amplifier /compressor from time of 10th XRL Conference in Berlin to present time of 11th XRL Conference in Belfast. One of the main objectives of RBS laser system development is to use it for pumping of recombination X-ray laser in transition to ground state of CVI ions at 3.4 nm. Using elaborate computer code the processes of Optical Field Ionization, electron energy distribution, and recombination were calculated. It was shown that in very earlier stage of recombination, when electron energy distribution is strongly non-Maxwellian, high gain in transition from the first excited level n=2 to ground level m=1 can be generated. Adding large amount of hydrogen gas into initial gas containing carbon atoms (e.g. methane, CH4) the calculated gain has reached values up to 150-200 cm-2 Taking into account this very encouraging result, we have proceed with arrangement of experimental setup. We will present the observation of plasma channels and measurements of electron density distribution required for generation of gain at 3.4 nm.

  2. Ultrastructural analysis of root canal dentine irradiated with 980-nm diode laser energy at different parameters.

    Science.gov (United States)

    Marchesan, Melissa Andréia; Brugnera-Junior, Aldo; Souza-Gabriel, Aline Evangelista; Correa-Silva, Silvio Rocha; Sousa-Neto, Manoel D

    2008-06-01

    The purpose of this in vitro study was to investigate using the scanning electron microscope (SEM) the ultrastructural morphological changes of the radicular dentine surface after irradiation with 980-nm diode laser energy at different parameters and angles of incidence. There have been limited reports on the effects of diode laser irradiation at 980 nm on radicular dentin morphology. Seventy-two maxillary canines were sectioned and roots were biomechanically prepared using K3 rotary instruments. The teeth were irrigated with 2 mL of distilled water between files and final irrigation was performed with 10 mL of distilled water. The teeth were then randomly divided into five groups (n = 8 each) according to their diode laser parameters: Group 1: no irradiation (control); group 2: 1.5 W/continuous wave (CW) emission (the manufacturer's parameters); group 3: 1.5 W/100 Hz; group 4: 3 W/CW; and group 5: 3 W/100 Hz. Laser energy was applied with helicoid movements (parallel to the canal walls) for 20 sec. Eight additional teeth for each group were endodontically prepared and split longitudinally and irradiation was applied perpendicularly to the root surface. Statistical analysis showed no difference between the root canal thirds irradiated with the 980-nm diode laser, and similar results between the parameters 1.5 W/CW and 3 W/100 Hz (p > 0.05). When considering different output powers and delivery modes our results showed that changes varied from smear layer removal to dentine fusion.

  3. Efficient high power operation of erbium 3 µm fibre laser diode-pumped at 975 nm

    NARCIS (Netherlands)

    Jackson, S.D.; King, T.A.; Pollnau, Markus

    2000-01-01

    Efficient CW operation of a 2.71 um Er,Pr:ZBLAN double-clad fibre laser pumped with a single diode laser operating at a wavelength of 975 nm is described. A maximum output power of 0.5 W and a slope efficiency of 25% (with respect to the launched pump power) were obtained. Threshold pump powers of <

  4. Etching microscopic defects in polycarbonate due to high dose ArF or KrF laser exposure

    Energy Technology Data Exchange (ETDEWEB)

    Jaleh, B. [Physics Department, Bu- Alisina University, Hamadan (Iran, Islamic Republic of); Parvin, P. [Physics Department, Amirkabir University, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of) and Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of) ]. E-mail: parvin@aut.ac.ir; Katoozi, M. [National Radiation Protection Department, AEOI, Tehran (Iran, Islamic Republic of); Zamani, Z. [Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of); Zare, A. [Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of)

    2005-11-15

    The ArF or KrF excimer laser exposure on the polycarbonate (PC) with corresponding doses higher than {phi}{sub th}5.2J/cm{sup 2}, at 32mJ/cm{sup 2} fluence per pulse and 5Hz pulse repetition rate (PRR), induces regular defects leading to self assembled defect structure following electrochemical etching (ECE). We have observed the conical-like structure for {phi}>{phi}{sub th}, whereas the polymer experiences hardening effect due to crosslinking when {phi}<{phi}{sub th}. Subsequently, conical-like, structure turns into track-like pits developing under ECE multiple treeing. Self assembled defect structure may be seen by naked eye as white spots, despite SEM illustrates a type of periodic pit formation-morphology. The exact explanation of the effect is not well understood yet. It looks like alpha tracks in the polymer surface, however the PC pieces were simply treated by excimer lasers at high doses, and they have not been exposed to the nuclear particles afterwards. We could not observe those effects at 308nm (XeCl laser) or longer wavelengths at 351nm (XeF laser) where UV photoablation does not occur. It indicates that UV ablation establishes surface degradation at shorter wavelengths, leading to laser micro etching. The mean track (defect) density is about one order of magnitude greater than the normal alpha tracks. Increasing UV doses, polymer undergoes a plateau, corresponding to etched defect saturation on PC.

  5. Etching microscopic defects in polycarbonate due to high dose ArF or KrF laser exposure

    International Nuclear Information System (INIS)

    Jaleh, B.; Parvin, P.; Katoozi, M.; Zamani, Z.; Zare, A.

    2005-01-01

    The ArF or KrF excimer laser exposure on the polycarbonate (PC) with corresponding doses higher than φ th 5.2J/cm 2 , at 32mJ/cm 2 fluence per pulse and 5Hz pulse repetition rate (PRR), induces regular defects leading to self assembled defect structure following electrochemical etching (ECE). We have observed the conical-like structure for φ>φ th , whereas the polymer experiences hardening effect due to crosslinking when φ th . Subsequently, conical-like, structure turns into track-like pits developing under ECE multiple treeing. Self assembled defect structure may be seen by naked eye as white spots, despite SEM illustrates a type of periodic pit formation-morphology. The exact explanation of the effect is not well understood yet. It looks like alpha tracks in the polymer surface, however the PC pieces were simply treated by excimer lasers at high doses, and they have not been exposed to the nuclear particles afterwards. We could not observe those effects at 308nm (XeCl laser) or longer wavelengths at 351nm (XeF laser) where UV photoablation does not occur. It indicates that UV ablation establishes surface degradation at shorter wavelengths, leading to laser micro etching. The mean track (defect) density is about one order of magnitude greater than the normal alpha tracks. Increasing UV doses, polymer undergoes a plateau, corresponding to etched defect saturation on PC

  6. An in vivo photodynamic therapy with diode laser to cell activation of kidney dysfunction

    International Nuclear Information System (INIS)

    Astuti, Suryani Dyah; Prasaja, Brahma Indra; Prijo, Tri Anggono

    2017-01-01

    This study aims to analyze the effect of photodynamic therapy (PDT) low level laser therapy (LLLT) 650 nm in the experimental animals mice ( Musmuculus ) suffering from kidney organ damage in mice ( Musmuculus ) in vivo. Exposure laser acupuncture was performed on the kidney BL-23. The conditioning of kidney damage in mice used carbofuraan 35 at a dose of 0.041697 mg/mice. LLLT 650 nm exposure was done on a wide variety of energy (0.5; 1.0; 1.5; 2.0; 4.0; 5.0; 6.0; 7.0) J. The histopathological kidney cells in mice renal impairment showed that exposure to 650 nm laser energy 1 Joule resulted in the reduction of damaged cells (necrosis) and normal cells were increased with the improvement of renal tubular cells (64.14 ± 8:02)%. Therefore, exposure to 650 nm LLLT on acupuncture points Shenshu (BL-23) has the ability to proliferation of renal tubular cells of mice. (paper)

  7. An in vivo photodynamic therapy with diode laser to cell activation of kidney dysfunction

    Science.gov (United States)

    Dyah Astuti, Suryani; Indra Prasaja, Brahma; Anggono Prijo, Tri

    2017-05-01

    This study aims to analyze the effect of photodynamic therapy (PDT) low level laser therapy (LLLT) 650 nm in the experimental animals mice (Musmuculus) suffering from kidney organ damage in mice (Musmuculus) in vivo. Exposure laser acupuncture was performed on the kidney BL-23. The conditioning of kidney damage in mice used carbofuraan 35 at a dose of 0.041697 mg/mice. LLLT 650 nm exposure was done on a wide variety of energy (0.5; 1.0; 1.5; 2.0; 4.0; 5.0; 6.0; 7.0) J. The histopathological kidney cells in mice renal impairment showed that exposure to 650 nm laser energy 1 Joule resulted in the reduction of damaged cells (necrosis) and normal cells were increased with the improvement of renal tubular cells (64.14 ± 8:02)%. Therefore, exposure to 650 nm LLLT on acupuncture points Shenshu (BL-23) has the ability to proliferation of renal tubular cells of mice.

  8. The effects of 595- and 1,064-nm lasers on rooster comb blood vessels using dual-wavelength and multipulse techniques.

    Science.gov (United States)

    Li, Guang; Sun, Jianfang; Shao, Xuebao; Sang, Honggui; Zhou, Zhanchao

    2011-10-01

    After laser irradiation, hemoglobin can transform into methemoglobin and coagulum, which have high absorptivity of near-infrared light. Sequential irradiation with 595 nm and 1,064 nm may be more effective than single wavelength to decrease residual vessel number in rooster combs. Six protocols (single pulse with 595 nm, double pulse with 595 nm, single pulse with 1,064 nm, double pulse with 1,064 nm, sequential irradiation with 595 nm and 1,064 nm (multiplex), and a blank control group) were used to compare the effects of sequential and single-wavelength irradiation on reducing residual vessel number, as well as the epidermal side effects, in the rooster comb. Different treatment techniques were applied to the same comb, at the same time. The treated areas of the epidermis and the residual vessels were observed using an optical microscope. All five techniques were effective in decreasing the number of residual vessels in the comb, and the side effects on the epidermis were similar for all. Considering the selectivity of the 595-nm laser and the rich melanin in the human epidermis, the dual-wavelength laser has a distinct advantage in treating vascular lesions. The authors have indicated no significant interest with commercial supporters. © 2011 by the American Society for Dermatologic Surgery, Inc.

  9. Complete resolution of minocycline pigmentation following a single treatment with non-ablative 1550-nm fractional resurfacing in combination with the 755-nm Q-switched alexandrite laser.

    Science.gov (United States)

    Vangipuram, Ramya K; DeLozier, Whitney L; Geddes, Elizabeth; Friedman, Paul M

    2016-03-01

    Pigmentation secondary to minocycline ingestion is an uncommon adverse event affecting 3.7-14.8% of treated individuals for which few effective therapies are available. Three patterns of minocycline pigmentation have a characteristic clinical and histological appearance. The pigment composition in each variety is different and occurs at varying skin depths. Accordingly, a tailored approach according to the type of minocycline pigmentation is crucial for treatment success. The purpose of this intervention was to evaluate the efficacy of non-ablative fractional photothermolysis in combination with the Q-switched alexandrite laser for the treatment of type I minocycline pigmentation on the face. A patient with type I minocycline pigmentation was treated with non-ablative 1550-nm fractional photothermolysis followed immediately by 755-nm Q-switched alexandrite laser and then observed clinically to determine the outcome of this modality. The patient was seen in clinic 1 month later following her single treatment session and 100% clearance of all blue facial pigment was observed. Non-ablative fractional photothermolysis in combination with the 755-nm Q-switched alexandrite laser should be considered for treatment of type I minocycline pigmentation. © 2015 Wiley Periodicals, Inc.

  10. A 1470-nm laser combined with foam sclerotherapy in day surgery: a better choice for lower limb varicose veins.

    Science.gov (United States)

    Zhang, Xing; Wang, Xin; Gao, Cheng; Qin, Jinbao; Zhao, Haiguang; Li, Weimin; Lu, Xinwu

    2018-04-23

    Day surgery is being more and more adopted by clinicians. Higher wavelength lasers give patients better experience than lower wavelength lasers, which makes it more suitable for day surgery. This study compares the short- and mid-term efficacy, postoperative morbidity, and patient satisfaction of "1470-nm endovenous laser ablation (EVLA) combining foam sclerotherapy in day surgery" with "810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery" on great saphenous vein (GSV) insufficiency postoperatively. A single-institution historical cohort study of 194 patients was performed in Shanghai Ninth People's Hospital, China. Ninety-seven patients received 1470-nm EVLA combining foam sclerotherapy in day surgery ("1470-nm group"), and 97 patients received 810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery recommended by guidelines ("810-nm group"). No significant difference was found between the 1470-nm group and the 810-nm group in terms of GSV occlusion rate (both 100%), complication rate, and recurrence rate (8.2 vs. 11.3%) during the period of 1-12 months after surgery. Serious complications in the 1470-nm group and 810-nm group were 0 and 1.0%. Minor complications in the 1470-nm group and 810-nm group were ecchymosis at 20.6 and 18.6%, edema at 69.1 and 63.9%, and paresthesia around ankle at 0 and 3.1%, respectively. Advantage of the 1470-nm group over the 810-nm group was statistically significant considering the patient perioperative comfort and economic cost. Treatment of 1470-nm EVLA combining foam sclerotherapy in day surgery has similar efficacy as the 810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery in GSV insufficiency and is more comfortable with less incision, hospitalization procedure, and medical costs. It may be a new option for patients who are afraid or unable to be hospitalized.

  11. 980 nm high brightness external cavity broad area diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2009-01-01

    We demonstrate of-axis spectral beam combining applied to a 980 nm high power broad area diode laser bar. The experiments yielded 9 W of optical power at 30 A of operating current and the measured M2 values of the combined beam from 12 emitters were 1.9 and 6.4 for the fast and the slow axis......, respectively. The slow axis beam quality was 5-6 times better than the value obtained from a single emitter in free running mode. A high brightness of 79 MW/cm2-str was achieved using this configuration. To our knowledge, this is the highest brightness level ever achieved from a broad area diode laser bar....

  12. Ultrafast Self-Assembly of Sub-10 nm Block Copolymer Nanostructures by Solvent-Free High-Temperature Laser Annealing.

    Science.gov (United States)

    Jiang, Jing; Jacobs, Alan G; Wenning, Brandon; Liedel, Clemens; Thompson, Michael O; Ober, Christopher K

    2017-09-20

    Laser spike annealing was applied to PS-b-PDMS diblock copolymers to induce short-time (millisecond time scale), high-temperature (300 to 700 °C) microphase segregation and directed self-assembly of sub-10 nm features. Conditions were identified that enabled uniform microphase separation in the time frame of tens of milliseconds. Microphase ordering improved with increased temperature and annealing time, whereas phase separation contrast was lost for very short annealing times at high temperature. PMMA brush underlayers aided ordering under otherwise identical laser annealing conditions. Good long-range order for sub-10 nm cylinder morphology was achieved using graphoepitaxy coupled with a 20 ms dwell laser spike anneal above 440 °C.

  13. Laser exposure incidents: pilot ocular health and aviation safety issues.

    Science.gov (United States)

    Nakagawara, Van B; Wood, Kathryn J; Montgomery, Ron W

    2008-09-01

    A database of aviation reports involving laser illumination of flight crewmembers has been established and maintained at the Civil Aerospace Medical Institute. A review of recent laser illumination reports was initiated to investigate the significance of these events. Reports that involved laser exposures of civilian aircraft in the United States were analyzed for the 13-month period (January 1, 2004, through January 31, 2005). There were 90 reported instances of laser illumination during the study period. A total of 53 reports involved laser exposure of commercial aircraft. Lasers illuminated the cockpit in 41 (46%) of the incidents. Of those, 13 (32%) incidents resulted in a visual impairment or distraction to a pilot, including 1 incident that reportedly resulted in an ocular injury. Nearly 96% of these reports occurred in the last 3 months of the study period. There were no aviation accidents in which laser light illumination was found to be a contributing factor. Operational problems have resulted from laser illumination incidents in the national airspace system. Eye care practitioners, to provide effective consultations to their pilot patients, should be familiar with the problems that can occur with laser exposure.

  14. Diode-pumped continuous-wave Nd:Gd3Ga5O12 lasers at 1406, 1415 and 1423 nm

    Science.gov (United States)

    Lin, Haifeng; Zhu, Wenzhang; Xiong, Feibing; Ruan, Jianjian

    2018-05-01

    We report a diode-pumped continuous-wave Nd:Gd3Ga5O12 (GGG) laser operating at 1.4 μm spectral region. A dual-wavelength laser at 1423 and 1406 nm is achieved with output power of about 2.59 W at absorbed pump power of 13.4 W. Further increasing the pump power, simultaneous tri-wavelength laser at 1423, 1415 and 1406 nm is also obtained with a maximum output power of 3.96 W at absorbed pump power of 18.9 W. Single-wavelength lasing is also realized at the three emission lines using an intracavity etalon. The laser result is believed to be the highest output power achieved in Nd:GGG crystal, at present, to the best of our knowledge.

  15. Low-threshold stimulated emission at 249 nm and 256 nm from AlGaN-based multiple-quantum-well lasers grown on sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiao-Hang; Detchprohm, Theeradetch; Kao, Tsung-Ting; Satter, Md. Mahbub; Shen, Shyh-Chiang; Douglas Yoder, P.; Dupuis, Russell D., E-mail: dupuis@gatech.edu [Center for Compound Semiconductors and School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0250 (United States); Wang, Shuo; Wei, Yong O.; Xie, Hongen; Fischer, Alec M.; Ponce, Fernando A. [Department of Physics, Arizona State University, Tempe, Arizona 85287-1504 (United States); Wernicke, Tim; Reich, Christoph; Martens, Martin; Kneissl, Michael [Technical University of Berlin, Institute for Solid State Physics, Berlin D-10623 (Germany)

    2014-10-06

    Optically pumped deep-ultraviolet (DUV) lasing with low threshold was demonstrated from AlGaN-based multiple-quantum-well (MQW) heterostructures grown on sapphire substrates. The epitaxial layers were grown pseudomorphically by metalorganic chemical vapor deposition on (0001) sapphire substrates. Stimulated emission was observed at wavelengths of 256 nm and 249 nm with thresholds of 61 kW/cm{sup 2} and 95 kW/cm{sup 2} at room temperature, respectively. The thresholds are comparable to the reported state-of-the-art AlGaN-based MQW DUV lasers grown on bulk AlN substrates emitting at 266 nm. These low thresholds are attributed to the optimization of active region and waveguide layer as well as the use of high-quality AlN/sapphire templates. The stimulated emission above threshold was dominated by transverse-electric polarization. This work demonstrates the potential candidacy of sapphire substrates for DUV diode lasers.

  16. Low-threshold stimulated emission at 249 nm and 256 nm from AlGaN-based multiple-quantum-well lasers grown on sapphire substrates

    International Nuclear Information System (INIS)

    Li, Xiao-Hang; Detchprohm, Theeradetch; Kao, Tsung-Ting; Satter, Md. Mahbub; Shen, Shyh-Chiang; Douglas Yoder, P.; Dupuis, Russell D.; Wang, Shuo; Wei, Yong O.; Xie, Hongen; Fischer, Alec M.; Ponce, Fernando A.; Wernicke, Tim; Reich, Christoph; Martens, Martin; Kneissl, Michael

    2014-01-01

    Optically pumped deep-ultraviolet (DUV) lasing with low threshold was demonstrated from AlGaN-based multiple-quantum-well (MQW) heterostructures grown on sapphire substrates. The epitaxial layers were grown pseudomorphically by metalorganic chemical vapor deposition on (0001) sapphire substrates. Stimulated emission was observed at wavelengths of 256 nm and 249 nm with thresholds of 61 kW/cm 2 and 95 kW/cm 2 at room temperature, respectively. The thresholds are comparable to the reported state-of-the-art AlGaN-based MQW DUV lasers grown on bulk AlN substrates emitting at 266 nm. These low thresholds are attributed to the optimization of active region and waveguide layer as well as the use of high-quality AlN/sapphire templates. The stimulated emission above threshold was dominated by transverse-electric polarization. This work demonstrates the potential candidacy of sapphire substrates for DUV diode lasers.

  17. Performance of a 967 nm CW diode end-pumped Er:GSGG laser at 2.79 μm

    International Nuclear Information System (INIS)

    Wu, Z H; Sun, D L; Wang, S Z; Luo, J Q; Li, X L; Huang, L; Hu, A L; Tang, Y Q; Guo, Q

    2013-01-01

    We demonstrated a 967 nm diode end-pumped Er:GSGG laser operated at 2.794 μm with spectral width 3.6 nm in the continuous wave (CW) mode. A maximum output power of 440 mW is obtained at an incident pumping power of 3.4 W, which corresponds to an optical-to-optical efficiency of 13% and slope efficiency of 13.2%. The results suggest that a short cavity and efficient cooling setup for the crystal help to improve laser performance. (paper)

  18. The 808 nm Laser-Assisted Surgery as an Adjunct to Orthodontic Treatment of Delayed Tooth Eruption.

    Science.gov (United States)

    Seifi, Massoud; Vahid-Dastjerdi, Elahe; Ameli, Nazila; Badiee, Mohammad-Reza; Younessian, Farnaz; Amdjadi, Parisa

    2013-01-01

    Failure of teeth to erupt from gingival tissues at usual developmental time is called delayed tooth eruption (DTE). Delayed tooth eruption lead to prolonged fixed orthodontic treatment and its eventual complications. The purpose of the present study was to evaluate the effect of laser-assisted (808 nm) surgical uncovering, on the tooth emergence and orthodontic treatment of DTE. A total of 16 orthodontic patients were included in this study and were equally assigned to an experimental and a control group. Subjects for experiment consisted of eight patients (6 girls and 2 boys) with a mean age of 14±0.9 years. All patients exhibited delayed second premolar eruption. The laser wavelength was 810 nm and it was set in a continuous wave mode at a power output of 1.6 watt with a 0.3-mm diameter fiber tip. When the target tissue was sufficiently anesthetized, the tip was directed at an angle of 10 to 20 degrees to the tissue (light contact mode); and was applied continuously for approximately 12 Seconds until an acceptable tooth exposure area was visible. The facial axis of the clinical crown (FACC) line represents the most prominent portion of the facial central lobe for premolars. All orthodontic brackets are aligned along this reference and are located on FA (Facial Axis) point. The standard for adequate tooth eruption was the accessibility of facial axis of the clinical crown (FACC) for bonding the brackets. Data gathered from the patients were statistically surveyed and compared by means of Tukey's Test and Analysis of Variance (ANOVA). All patients showed good gingival status, no significant bleeding during or immediately after the surgery, and acceptable level of healing after laser surgery. The biologic width of the teeth was preserved and no violation of this important periodontal parameter was observed. The average time for accessing the FA point in experimental group was 11±1.1 weeks and the mentioned period was increased to 25±1.8 weeks in control group

  19. Influence of ingaalp laser (660nm on the healing of skin wounds in diabetic rats Influência do laser ingaalp (660nm na cicatrização de feridas cutâneas em ratos diabéticos

    Directory of Open Access Journals (Sweden)

    Paulo de Tarso Camillo de Carvalho

    2010-02-01

    Full Text Available PURPOSE: To determine the influence of low-power laser (660 nm on the collagen percentage and macrophages in skin wounds in diabetic rats. METHODS: 30 male Wistar rats were used, distributed in two groups: laser treated diabetic (n= 15; untreated diabetic (n = 15. The diabetes was induced by intravenous injection of alloxan into the dorsal vein of the penis, at a rate of 0.1 ml of solution per 100 g of body weight. A wound was made on the back of all the animals. Groups 2 were treated with Aluminium Gallium Indium Phosphide - InGaAlP type diode laser (Photon Laser III DMC® with a continuous output power of 100 mW and wavelength (? of 660 nm (4 J/cm² for 24 s. five animal from each group was sacrificed on the 3rd, 7th and 14th days after wounding. Samples were taken, embedded in paraffin, stained with hematoxylin-eosin, Masson's trichrome, and immunohistochemical macrophage. morphometrically analyzed using the Image Pro Plus 4.5 software. The percentages of collagen fibers and macrophages were determined from the samples from the euthanasia animals. RESULTS: The data were treated statistically using analysis of variance (ANOVA and the Post-hocTukey test. The significance level was set at 0.05 or 5%. CONCLUSION: The low-power laser (660 nm was shown to be capable of influencing the collagen percentage in skin wounds by increasing the mean quantity of collagen fibers and macrophages.OBJETIVO: Determinar a influência do diodo laser InGaAlP (660 nm sobre o percentual de colágeno e macrófagos em feridas cutâneas de ratos diabéticos. MÉTODOS: Para tanto 30 ratos machos Wistar foram distribuídos em dois grupos: diabético tratado com laser (n=15, diabético não tratado (n = 15. O diabetes foi induzido por injeção intravenosa de aloxana na veia dorsal do pênis, a uma taxa de 0,1 ml de solução por 100 g de peso corporal. A lesão foi confeccionada no dorso de todos os animais utilizando um punch de 8mm. 2 grupos foram tratados com o diodo

  20. Experimental studies for improvement of thermal effects in a high-power fiber-coupled diode laser module operating at 808 nm

    Science.gov (United States)

    El-Sherif, Ashraf F.; Hussein, Khalid; Hassan, Mahmoud F.; Talat, Mahmoud M.

    2012-03-01

    High power diode laser module operating at 808 nm is required for different applications, such as developing an efficient high power Nd3+-doped solid state laser and Tm3+ -doped silica fiber laser, industrial, medical and military applications. Optical and thermal images characterization for a fiber-coupled high power diode laser module is presented experimentally for 6.6 Watt output optical power .An external temperature controller system was designed, which stabilizes the central wavelength at 808 nm at 25°C over a wide range of diode laser driving current from 1A to 6 A. without this cooling system, the wavelength changes by 0.35nm/°C for temperature changes from 20°C to 40°C at the same range of the driving current. In this paper we have present a methodology for temperature reduction of a 808 nm high power diode laser module, based on dynamically thermal control, which is known as dynamic thermal management. Stabilization of the output wavelength has been done by using proportional speed control (PSC) of a CPU cooling fan with certain scheme of straight fins heat sink. Two electronic circuits based on pulse width modulation (PWM) in microcontroller and comparators IC have been used. This technique can be considered as an effective mechanism for reducing temperature and power dissipation to make stabilization of the diode laser output wavelength by preventing heat accumulation from the thermo electric cooling (TEC) inside the diode laser module confirmed by thermal images.

  1. 36 W Q-switched Ho:YAG laser at 2097 nm pumped by a Tm fiber laser: evaluation of different Ho3+ doping concentrations

    Science.gov (United States)

    Antipov, O. L.; Eranov, I. D.; Kositsyn, R. I.

    2017-01-01

    A laser oscillator based on Ho:YAG crystal pumped by a Tm fiber laser with an acousto-optical Q-switch was optimized for maximum output power and pulse-to-pulse stability. Stable operation at 2097 nm in Q-switched mode is demonstrated, with pulse repetition rates from 10 to 30 kHz, and output power of 36 W (at 55 W of pump power at 1908 nm) in the good quality beam. The influence of Ho ion up-conversion and thermal lensing on the oscillation efficiency is discussed.

  2. Relationship between 578-nm (copper vapor) laser beam geometry and heat distribution within biological tissues

    Science.gov (United States)

    Ilyasov, Ildar K.; Prikhodko, Constantin V.; Nevorotin, Alexey J.

    1995-01-01

    Monte Carlo (MC) simulation model and the thermoindicative tissue phantom were applied for evaluation of a depth of tissue necrosis (DTN) as a result of quasi-cw copper vapor laser (578 nm) irradiation. It has been shown that incident light focusing angle is essential for DTN. In particular, there was a significant rise in DTN parallel to elevation of this angle up to +20 degree(s)C and +5 degree(s)C for both the MC simulation and tissue phantom models, respectively, with no further increase in the necrosis depth above these angles. It is to be noted that the relationship between focusing angles and DTN values was apparently stronger for the real target compared to the MC-derived hypothetical one. To what extent these date are applicable for medical practice can be evaluated in animal models which would simulate laser-assisted therapy for PWS or related dermatologic lesions with converged 578 nm laser beams.

  3. Diode-pumped laser performance of Tm:Sc2SiO5 crystal at 1971 nm

    International Nuclear Information System (INIS)

    Liu Bin; Wang Qing-Guo; Tang Hui-Li; Wu Feng; Luo Ping; Zhao Heng-Yu; Shi Jiao-Jiao; He Nuo-Tian; Li Na; Li Qiu; Guo Chao; Wang Zhan-Shan; Xu Jun; Zheng Li-He; Su Liang-Bi; Liu Jun-Fang; Liu Jie; Fan Xiu-Wei; Xu Xiao-Dong

    2017-01-01

    The 4-at.% Tm:Sc 2 SiO 5 (Tm:SSO) crystal is successfully obtained by the Czochralski method. The optical properties and thermal conductivity of the crystal are investigated. The broad continuous wave (CW) laser output of (100)-cut Tm:SSO with the dimensions of 3 mm× 3 mm× 3 mm under laser diode (LD)-pumping is realized. The full width at half maximum (FWHM) of the laser emitting reaches up to 21 nm. The laser threshold of Tm:SSO is measured to be 0.43 W. Efficient diode-pumped CW laser performance of Tm:SSO is demonstrated with a slope efficiency of 25.9% and maximum output power of 934 mW. (paper)

  4. Low intensity 635 nm diode laser irradiation inhibits fibroblast-myofibroblast transition reducing TRPC1 channel expression/activity: New perspectives for tissue fibrosis treatment.

    Science.gov (United States)

    Sassoli, Chiara; Chellini, Flaminia; Squecco, Roberta; Tani, Alessia; Idrizaj, Eglantina; Nosi, Daniele; Giannelli, Marco; Zecchi-Orlandini, Sandra

    2016-03-01

    Low-level laser therapy (LLLT) or photobiomodulation therapy is emerging as a promising new therapeutic option for fibrosis in different damaged and/or diseased organs. However, the anti-fibrotic potential of this treatment needs to be elucidated and the cellular and molecular targets of the laser clarified. Here, we investigated the effects of a low intensity 635 ± 5 nm diode laser irradiation on fibroblast-myofibroblast transition, a key event in the onset of fibrosis, and elucidated some of the underlying molecular mechanisms. NIH/3T3 fibroblasts were cultured in a low serum medium in the presence of transforming growth factor (TGF)-β1 and irradiated with a 635 ± 5 nm diode laser (continuous wave, 89 mW, 0.3 J/cm(2) ). Fibroblast-myofibroblast differentiation was assayed by morphological, biochemical, and electrophysiological approaches. Expression of matrix metalloproteinase (MMP)-2 and MMP-9 and of Tissue inhibitor of MMPs, namely TIMP-1 and TIMP-2, after laser exposure was also evaluated by confocal immunofluorescence analyses. Moreover, the effect of the diode laser on transient receptor potential canonical channel (TRPC) 1/stretch-activated channel (SAC) expression and activity and on TGF-β1/Smad3 signaling was investigated. Diode laser treatment inhibited TGF-β1-induced fibroblast-myofibroblast transition as judged by reduction of stress fibers formation, α-smooth muscle actin (sma) and type-1 collagen expression and by changes in electrophysiological properties such as resting membrane potential, cell capacitance and inwardly rectifying K(+) currents. In addition, the irradiation up-regulated the expression of MMP-2 and MMP-9 and downregulated that of TIMP-1 and TIMP-2 in TGF-β1-treated cells. This laser effect was shown to involve TRPC1/SAC channel functionality. Finally, diode laser stimulation and TRPC1 functionality negatively affected fibroblast-myofibroblast transition by interfering with TGF-β1 signaling, namely reducing the

  5. Diode-side-pumped intracavity frequency-doubled Nd:YAG/BaWO4 Raman laser generating average output power of 3.14 W at 590 nm.

    Science.gov (United States)

    Li, Shutao; Zhang, Xingyu; Wang, Qingpu; Zhang, Xiaolei; Cong, Zhenhua; Zhang, Huaijin; Wang, Jiyang

    2007-10-15

    We report a linear-cavity high-power all-solid-state Q-switched yellow laser. The laser source comprises a diode-side-pumped Nd:YAG module that produces 1064 nm fundamental radiation, an intracavity BaWO(4) Raman crystal that generates a first-Stokes laser at 1180 nm, and a KTP crystal that frequency doubles the first-Stokes laser to 590 nm. A convex-plane cavity is employed in this configuration to counteract some of the thermal effect caused by high pump power. An average output power of 3.14 W at 590 nm is obtained at a pulse repetition frequency of 10 kHz.

  6. Laser cutting of bone tissue under bulk water with a pulsed ps-laser at 532 nm.

    Science.gov (United States)

    Tulea, Cristian-Alexander; Caron, Jan; Gehlich, Nils; Lenenbach, Achim; Noll, Reinhard; Loosen, Peter

    2015-10-01

    Hard-tissue ablation was already investigated for a broad variety of pulsed laser systems, which cover almost the entire range of available wavelengths and pulse parameters. Most effective in hard-tissue ablation are Er:YAG and CO2 lasers, both utilizing the effect of absorption of infrared wavelengths by water and so-called explosive vaporization, when a thin water film or water–air spray is supplied. The typical flow rates and the water layer thicknesses are too low for surgical applications where bleeding occurs and wound flushing is necessary. We studied a 20 W ps-laser with 532 nm wavelength and a pulse energy of 1 mJ to effectively ablate bones that are submerged 14 mm under water. For these laser parameters, the plasma-mediated ablation mechanism is dominant. Simulations based on the blow-off model predict the cut depth and cross-sectional shape of the incision. The model is modified considering the cross section of the Gaussian beam, the incident angle, and reflections. The ablation rate amounts to 0.2  mm3/s, corresponding to an increase by at least 50% of the highest values published so far for ultrashort laser ablation of hard tissue.

  7. High-power Al-free active region (λ= 852nm) DFB laser diodes for atomic clocks and interferometry applications

    Science.gov (United States)

    Ligeret, V.; Vermersch, F.-J.; Bansropun, S.; Lecomte, M.; Calligaro, M.; Parillaud, O.; Krakowski, M.

    2017-11-01

    Atomic clocks will be used in the future European positioning system Galileo. Among them, the optically pumped clocks provide a better alternative with comparable accuracy for a more compact system. For these systems, diode lasers emitting at 852nm are strategic components. The laser in a conventional bench for atomic clocks presents disadvantages for spatial applications. A better approach would be to realise a system based on a distributed-feedback laser (DFB). We have developed the technological foundations of such lasers operating at 852nm. These include an Al free active region, a single spatial mode ridge waveguide and a DFB structure. The device is a separate confinement heterostructure with a GaInP large optical cavity and a single compressive strained GaInAsP quantum well. The broad area laser diodes are characterised by low internal losses (value of less than 2MHz.

  8. Diode-pumped continuous-wave blue laser operation of Nd:GGG at 467.0, 467.7, and 468.5 nm

    International Nuclear Information System (INIS)

    Xu, B; Camy, P; Doualan, J L; Braud, A; Moncorgé, R; Cai, Z P; Brenier, A

    2012-01-01

    Intra-cavity frequency doubling of continuous-wave (CW) laser emission on the quasi-three level ( 4 F 3/2 → 4 I 9/2 ) laser transition of Nd 3+ in Nd:GGG is reported by using a three-mirror folded resonator. The thermal lens experienced by the optically-pumped Nd:GGG laser crystal is measured as a function of the absorbed pump power and compared to that found, in the same conditions, in the case of Nd:YAG. Results are interpreted by using a simple model accounting for the absorbed pump power and the thermo-mechanical properties of each laser crystal. Diode-pumped blue laser operation is achieved, for the first time, at 467.0 and 468.5 nm with output powers of 230 and 450 mW, respectively. Simultaneous laser operation resulting both from frequency-doubling and frequency summing at the three 467.1, 467.7, and 468.1 nm laser wavelengths is also obtained with a total output power of 60 mW

  9. Optical spectroscopy of rubidium Rydberg atoms with a 297 nm frequency doubled dye laser

    International Nuclear Information System (INIS)

    Becker, Th.; Germann, Th.; Thoumany, P.; Stania, G.; Urbonas, L.; Haensch, T.

    2008-01-01

    Full text: Rydberg atoms have played an important role in atomic physics and optical spectroscopy since many years. Due to their long lifetime and the big dipole matrix element between neighbouring Rydberg levels they are an essential tool in microwave cavity-qed experiments. Ultracold Rydberg gases are a promising candidate for realizing controlled quantum gates in atomic ensembles. In most experiments Rydberg atoms are detected destructively, where the optically excited atoms are first ionized followed by an electronic detection of the ionization products. A Doppler-free purely optical detection was reported in a room temperature cell and in an atomic beam apparatus using the technique of electromagnetically induced transparency. In all these experiments the Rydberg atoms are excited with two lasers in a two-step ladder configuration. Here we show that Doppler-free purely optical spectroscopy is also possible with a one step excitation scheme involving a UV laser at 297 nm. We excite the 85 Rb isotope from the 5S 1/2 ground state to the 63P 3/2 state with a frequency doubled dye laser in a room temperature gas cell without buffer gas. Rydberg transitions are detected by monitoring the absorption of 780 nm laser light which is superimposed on the UV light and resonant with one hyperfine component of the Rubidium D2 line. With these two lasers we realize a V-scheme and utilize the quantum amplification effect due to the different natural lifetimes of the upper levels of the two transitions: an excitation into the 63P level hinders many absorption-emission cycles of the D2 transition and leads to a reduced absorption on that line. We discuss the shape of the observed spectra in the context of electron shelving and EIT experiments. By applying a frequency modulation to the UV laser, we can obtain dispersive signals which can be used to stabilize the laser to a specific Rydberg transition. By shifting the frequency of the 780 nm laser to crossover resonances in the

  10. Application of 810-nm diode laser in the management of peripheral ossifying fibroma

    Directory of Open Access Journals (Sweden)

    Beela Ram Anuradha

    2015-01-01

    Full Text Available Peripheral ossifying fibroma (POF is a reactive gingival growth, which accounts for 9.6% of gingival lesions. It exhibits a peak incidence between the second and third decades of life with a female predilection. Treatment includes surgical excision down to the periosteum and periodontal ligament with thorough root planning. Another option available in place of conventional surgical excision is the excision using lasers. Here is a case of POF affecting anterior maxillary gingiva in 19-year-old male patient successfully managed using an 810-nm diode laser.

  11. Laser Phototherapy (660 nm Can Be Beneficial for Reducing Gingival Inflammation in Prosthodontics

    Directory of Open Access Journals (Sweden)

    Sávio José Cardoso Bezerra

    2015-01-01

    Full Text Available Among the new technologies developed, low power lasers have enabled new approaches to provide conservative treatment. Low power lasers act at cellular level, resulting in reduced pain, modulating inflammation, and improved tissue healing. Clinical application of the low power laser requires specific knowledge concerning laser interaction with biological tissue so that the correct irradiation protocol can be established. The present case report describes the clinical steps involved in an indirect composite resin restoration performed in a 31-year-old patient, in whom low power laser was used for soft tissue biomodulation. Laser therapy was applied with a semiconductor laser 660 nm, spot size of 0.028 cm2, energy density of 35.7 J/cm2, mean power of 100 mW, and energy per point as 1 J, in contact mode, on a total of 2 points (mesial and distal, totaling 2 J of energy. The therapy with low power laser can contribute positively to the success of an indirect restorative treatment.

  12. 375-nm ultraviolet-laser based non-line-of-sight underwater optical communication

    KAUST Repository

    Sun, Xiaobin

    2018-05-04

    For circumventing the alignment requirement of line-of-sight (LOS) underwater wireless optical communication (UWOC), we demonstrated a non-line-of-sight (NLOS) UWOC link adequately enhanced using ultraviolet (UV) 375-nm laser. Path loss was chosen as a figure-of-merit for link performance in this investigation, which considers the effects of geometries, water turbidity, and transmission wavelength. The experiments suggest that path loss decreases with smaller azimuth angles, higher water turbidity, and shorter wavelength due in part to enhanced scattering utilizing 375-nm radiation. We highlighted that it is feasible to extend the current findings for long distance NLOS UWOC link in turbid water, such as harbor water.

  13. Liposucción con diodo láser 980-nm (LSDL 980-nm: optimización de protocolo seguro en cirugía de contorno corporal Body contouring using laser diode 980-nm (LSDL 980-nm assisted lipolysis: a safe procedure

    Directory of Open Access Journals (Sweden)

    P. Centurión

    2011-12-01

    Full Text Available La disponibilidad en el mercado de una gran gama de equipos de láser de diferentes potencias y longitudes de onda para su aplicación en el tejido graso, así como la existencia de diversos trabajos científicos sobre el tema con resultados opuestos, han causado gran confusión y dudas sobre la técnica de láser-lipolisis entre los cirujanos plásticos. Presentamos un protocolo quirúrgico de liposucción con diodo-láser de 980-nm (LSDL 980-nm aplicado en 240 pacientes. Evaluamos la seguridad de la técnica según el índice de complicaciones sufrido, así como la evolución en el post-operatorio de los pacientes tratados. Empleamos un equipo diodo-láser-980 nm (ORlight ®, cuya energía llevamos a través de una fibra de 600 μm. Esto se traduce en la aplicación de 99 J por cada cm² de área tratada, con un espesor de hasta 4 cm de tejido adiposo subcutáneo. No tuvimos complicaciones mayores, tipo quemaduras y entre las complicaciones menores, que fueron de un 48.33 % (116 pacientes, encontramos equímosis mínimas (menos del 2 % de superficie corporal. El tiempo que los pacientes requirieron para controlar el dolor postoperatorio fue de entre 1 y 2 días. Consideramos importante la incorporación de la LSDL-980 nm por ser una técnica menos traumática y con bajo índice de complicaciones, que reduce el periodo de recuperación de los pacientes, provoca una importante retracción de la piel y disminuye el dolor postoperatorio.The availability of multiple laser systems on the market with different power and wavelengths and the existence of several scientific papers with contradictory presents, have created great confusion and doubts among plastic surgeons with regard to the laser lipolysis technique. We report a surgical protocol for liposuction diode laser-980 nm (LSDL-980 nm applied to 240 patients. We evaluate the security of the technique according to the complication rate and the postoperative development of patients submitted to

  14. Broadband Fourier domain mode-locked laser for optical coherence tomography at 1060 nm

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Klein, Thomas; Wieser, Wolfgang

    2012-01-01

    Optical coherence tomography (OCT) in the 1060nm range is interesting for in vivo imaging of the human posterior eye segment (retina, choroid, sclera) due to low absorption in water and deep penetration into the tissue. Rapidly tunable light sources, such as Fourier domain mode-locked (FDML) lasers...

  15. Sub?40?fs, 1060?nm Yb?fiber laser enhances penetration depth in nonlinear optical microscopy of human skin

    OpenAIRE

    Balu, Mihaela; Saytashev, Ilyas; Hou, Jue; Dantus, Marcos; Tromberg, Bruce J.

    2015-01-01

    © 2015 The Authors. Advancing the practical utility of nonlinear optical microscopy requires continued improvement in imaging depth and contrast. We evaluated second-harmonic generation (SHG) and third-harmonic generation images from ex vivo human skin and showed that a sub-40 fs, 1060-nm Yb-fiber laser can enhance SHG penetration depth by up to 80% compared to a > 100 fs, 800 nm Ti:sapphire source. These results demonstrate the potential of fiber-based laser systems to address a key perform...

  16. Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode.

    Science.gov (United States)

    Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju

    2015-11-16

    Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.

  17. Emission parameters and thermal management of single high-power 980-nm laser diodes

    International Nuclear Information System (INIS)

    Bezotosnyi, V V; Krokhin, O N; Oleshchenko, V A; Pevtsov, V F; Popov, Yu M; Cheshev, E A

    2014-01-01

    We report emission parameters of high-power cw 980-nm laser diodes (LDs) with a stripe contact width of 100 μm. On copper heat sinks of the C-mount type, a reliable output power of 10 W is obtained at a pump current of 10 A. Using a heat flow model derived from analysis of calculated and measured overall efficiencies at pump currents up to 20 A, we examine the possibility of raising the reliable power limit of a modified high-power LD mounted on heat sinks of the F-mount type using submounts with optimised geometric parameters and high thermal conductivity. The possibility of increasing the maximum reliable cw output power to 20 W with the use of similar laser crystals is discussed. (lasers)

  18. AlGaAs/GaAs laser diode bars (λ = 808 nm) with improved thermal stability

    International Nuclear Information System (INIS)

    Marmalyuk, A A; Ladugin, M A; Andreev, A Yu; Telegin, K Yu; Yarotskaya, I V; Meshkov, A S; Konyaev, V P; Sapozhnikov, S M; Lebedeva, E I; Simakov, V A

    2013-01-01

    Two series of AlGaAs/GaAs laser heterostructures have been grown by metal-organic vapour phase epitaxy, and 808-nm laser diode bars fabricated from the heterostructures have been investigated. The heterostructures differed in waveguide thickness and quantum well depth. It is shown that increasing the barrier height for charge carriers in the active region has an advantageous effect on the output parameters of the laser sources in the case of the heterostructures with a narrow symmetric waveguide: the slope of their power – current characteristics increased from 0.9 to 1.05 W A -1 . Thus, the configuration with a narrow waveguide and deep quantum well is better suited for high-power laser diode bars under hindered heat removal conditions. (lasers)

  19. AlGaAs/GaAs laser diode bars (λ = 808 nm) with improved thermal stability

    Energy Technology Data Exchange (ETDEWEB)

    Marmalyuk, A A; Ladugin, M A; Andreev, A Yu; Telegin, K Yu; Yarotskaya, I V; Meshkov, A S; Konyaev, V P; Sapozhnikov, S M; Lebedeva, E I; Simakov, V A [Open Joint-Stock Company M.F. Stel' makh Polyus Research Institute, Moscow (Russian Federation)

    2013-10-31

    Two series of AlGaAs/GaAs laser heterostructures have been grown by metal-organic vapour phase epitaxy, and 808-nm laser diode bars fabricated from the heterostructures have been investigated. The heterostructures differed in waveguide thickness and quantum well depth. It is shown that increasing the barrier height for charge carriers in the active region has an advantageous effect on the output parameters of the laser sources in the case of the heterostructures with a narrow symmetric waveguide: the slope of their power – current characteristics increased from 0.9 to 1.05 W A{sup -1}. Thus, the configuration with a narrow waveguide and deep quantum well is better suited for high-power laser diode bars under hindered heat removal conditions. (lasers)

  20. Picosecond laser damage of fused silica at 355 nm

    International Nuclear Information System (INIS)

    Meng Xiangjie; Liu Hongjie; Wang Fang; Zhang Zhen; An Xinyou; Huang Jin; Jiang Xiaodong; Wu Weidong; Ren Weiyi

    2013-01-01

    This paper studies the initiated damage threshold, the damage morphology and the subsequent damage growth on fused silica's input-surface and exit-surface under picosecond laser irradiation at 355 nm. Defects induced fluorescence on surface of the optical component is observed. The results demonstrate a significant dependence of the initiated damage on pulse duration and surface defects, and that of the damage growth on self-focusing, sub-surface defects. The damage-threshold is 3.98 J/cm 2 of input surface and 2.91 J/cm 2 of exit surface. The damage morphologies are quite different between input surface and exit surface. Slow growth behavior appears for the diameter of exit-surface and linear growth one for the depth of exit-surface in the lateral side of damage site with the increase of shot number. Defects have changed obviously compared with nanosecond laser damage in the damage area. Several main reasons such as electric intensification and self-focusing for the observed initiated damage and damage growth behavior are discussed. (authors)

  1. High average power Q-switched 1314 nm two-crystal Nd:YLF laser

    CSIR Research Space (South Africa)

    Botha, RC

    2015-02-01

    Full Text Available . 40, No. 4 / OPTICS LETTERS High average power Q-switched 1314 nm two-crystal Nd:YLF laser R. C. Botha,1,2,* W. Koen,3 M. J. D. Esser,3,4 C. Bollig,3,5 W. L. Combrinck,1,6 H. M. von Bergmann,2 and H. J. Strauss3 1HartRAO, P.O. Box 443...

  2. Recent progress of 638-nm high-power broad area laser diodes in Mitsubishi Electric

    Science.gov (United States)

    Kuramoto, Kyosuke; Abe, Shinji; Miyashita, Motoharu; Nishida, Takehiro; Yagi, Tetsuya

    2018-02-01

    Laser based displays have gathered much attention because only the displays can express full color gamut of Ultra-HDTV, ITU-R BT.2020. One of the displays uses the lasers under pulse such as a single spatial light modulator (SLM) projector, and the other does ones under CW such as a multiple SLM projector and a liquid crystal display. Both types require high-power lasers because brightness is the most important factor in the market. We developed two types of 638-nm multi-emitter high-power BA-LDs assembled on Φ9.0-TO, that is, triple emitter for pulse and dual emitter for CW. The triple emitter LD emitted exceeding 6.0 W peak power under 25°C, frequency of 120 Hz, and duty of 30%. At high temperature, 55°C, the peak power was approximately 2.9W. The dual emitter emitted exceeding 3.0W under 25°C, CW. It emitted up to 1.7 W at 55°C. WPE of the dual emitter reached 40.5% at Tc of 25°C, which is the world highest in 638-nm LD under CW to the best of our knowledge, although that of the triple emitter was 38.1%. Both LDs may be suitable for laser based display applications.

  3. Effectiveness of 308-nm Excimer Laser Therapy in Treating Alopecia Areata, Determined by Examining the Treated Sides of Selected Alopecic Patches.

    Science.gov (United States)

    Byun, Ji Won; Moon, Jong Hyuk; Bang, Chan Yl; Shin, Jeonghyun; Choi, Gwang Seong

    2015-01-01

    Some studies have reported the use of 308-nm excimer laser therapy for treating alopecia areata (AA); however, the effectiveness of this therapy on a theoretical basis has not yet been comparatively analyzed. To determine the therapeutic effect of excimer laser therapy on AA. One alopecic patch was divided into control and treated sides in 10 patients with AA. Then, 308-nm excimer laser therapy was administered twice a week for 12 weeks. Photograph and phototrichogram analyses were performed. Photographic assessments by both dermatologists and individuals of the general population showed objective improvements after excimer laser therapy. On the treated side, the hair count and hair diameter had statistically increased after treatment. However, only the hair diameter was found to be significantly high in the treated half when it was compared with the control side. The 308-nm excimer laser has a therapeutic effect on AA, which is proven by photograph and phototrichogram analysis by a side-by-side comparison. © 2015 S. Karger AG, Basel.

  4. Preparation and Characterization of Bragg Fibers for Delivery of Laser Radiation at 1064 nm

    Directory of Open Access Journals (Sweden)

    V. Matejec

    2013-04-01

    Full Text Available Bragg fibers offer new performance for transmission of high laser energies over long distances. In this paper theoretical modeling, preparation and characterization of Bragg fibers for delivery laser radiation at 1064 nm are presented. Investigated Bragg fibers consist of the fiber core with a refractive index equal to that of silica which is surrounded by three pairs of circular layers. Each pair is composed of one layer with a high and one layer with a low refractive index and characterized by a refractive-index difference around 0.03. Propagation constants and radiation losses of the fundamental mode in such a structure were calculated on the basis of waveguide optics. Preforms of the Bragg fibers were prepared by the MCVD method using germanium dioxide, phosphorous pentoxide and fluorine as silica dopants. The fibers with a diameter of 170 m were drawn from the preforms. Refractive-index profiles, angular distributions of the output power and optical losses of the prepared fibers were measured. Results of testing the fibers for delivery radiation of a pulse Nd:YAG laser at 1064 nm are also shown.

  5. Raman ratios on the repair of grafted surgical bone defects irradiated or not with laser (λ780 nm) or LED (λ850 nm).

    Science.gov (United States)

    Pinheiro, Antonio Luiz B; Soares, Luiz Guilherme P; Marques, Aparecida Maria C; Aciole, Jouber Mateus S; de Souza, Renato Aparecido; Silveira, Landulfo

    2014-09-05

    This work aimed to assess biochemical changes associated to mineralization and remodeling of bone defects filled with Hydroxyapatite+Beta-Beta-tricalcium phosphate irradiated or not with 2 light sources. Ratios of intensities, band position and bandwidth of selected Raman peaks of collagen and apatites were used. Sixty male Wistar rats were divided into 6 groups subdivided into 2 subgroups (15th and 30th days). A standard surgical defect was created on one femur of each animal. In 3 groups the defects were filled with blood clot (Clot, Clot+Laser and Clot+LED groups) and in the remaining 3 groups the defects were filled with biomaterial (Biomaterial, Biomaterial+Laser and Biomaterial+LED groups). When indicated, the defects were irradiated with either Laser (λ780 nm, 70 mW, Φ∼0.4 cm(2)) or LED (λ850±10 nm, 150 mW, Φ∼0.5 cm(2)), 20 J/cm(2) each session, at 48 h intervals/2 weeks (140 J/cm(2) treatment). Following sacrifice, bone fragments were analyzed by Raman spectroscopy. Statistical analysis (ANOVA General Linear Model, pRaman ratios of selected protein matrix and phosphate and carbonate HA indicated that the use of biphasic synthetic micro-granular HA+Beta-TCP graft improved the repair of bone defects, associated or not with Laser or LED light, because of the increasing deposition of HA. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Nearly fully compressed 1053 nm pulses directly obtained from 800 nm laser-seeded photonic crystal fiber below zero dispersion point

    Science.gov (United States)

    Refaeli, Zaharit; Shamir, Yariv; Ofir, Atara; Marcus, Gilad

    2018-02-01

    We report a simple robust and broadly spectral-adjustable source generating near fully compressed 1053 nm 62 fs pulses directly out of a highly-nonlinear photonic crystal fiber. A dispersion-nonlinearity balance of 800 nm Ti:Sa 20 fs pulses was obtained initially by negative pre-chirping and then launching the pulses into the fibers' normal dispersion regime. Following a self-phase modulation spectral broadening, some energy that leaked below the zero dispersion point formed a soliton whose central wavelength could be tuned by Self-Frequency-Raman-Shift effect. Contrary to a common approach of power, or, fiber-length control over the shift, here we continuously varied the state of polarization, exploiting the Raman and Kerr nonlinearities responsivity for state of polarization. We obtained soliton pulses with central wavelength tuned over 150 nm, spanning from well below 1000 to over 1150 nm, of which we could select stable pulses around the 1 μm vicinity. With linewidth of > 20 nm FWHM Gaussian-like temporal-shape pulses with 62 fs duration and near flat phase structure we confirmed high quality pulse source. We believe such scheme can be used for high energy or high power glass lasers systems, such as Nd or Yb ion-doped amplifiers and systems.

  7. Effect of barrier layers in burnthrough experiments with 351-nm laser illumination

    International Nuclear Information System (INIS)

    Delettrez, J.; Bradley, D.K.; Jaanimagi, P.A.; Verdon, C.P.

    1990-01-01

    The time-resolved x-ray emission is measured from spherical targets consisting of glass shells overcoated with plastic in which thin signature layers are embedded. These targets are illuminated at 351 nm by the 24-beam OMEGA laser system at the Laboratory for Laser Energetics of the University of Rochester. We measure a large burnthrough rate for bare plastic targets that can only be replicated in one-dimensional hydrodynamic simulations with laser intensities in excess of ten times the nominal intensity. We observe that the burnthrough times are affected by the presence of a thin outer coating (barrier layer). The burnthrough times depend strongly on the barrier-layer material and thickness, whereas one-dimensional simulation results predict only a small effect. Several processes are considered to explain these results: illumination nonuniformity, early shinethrough of the laser light through the plastic, prepulses, filamentation, self-focusing of hot spots, and the Rayleigh-Taylor instability. We conclude that mixing due to the Rayleigh-Taylor instability, enhanced by early shinethrough, is the most probable cause of the observed large burnthrough rates

  8. Effects of malicious ocular laser exposure in commercial airline pilots.

    Science.gov (United States)

    Palakkamanil, Mathew M; Fielden, Michael P

    2015-12-01

    Intentional malicious laser strikes on commercial pilots are committed by individuals who target a laser into airplane cockpits during takeoff and landing. Because laser exposure to pilots is a relatively new but growing occurrence, our study investigates the ocular effect of this laser exposure in pilots. Retrospective chart review by a single ophthalmologist. All commercial airline pilots (58 male, 3 female) who experienced a laser strike while flying between April 2012 and November 2014 who presented to our clinic were included. A retrospective chart review was performed in a retinal specialist's practice. Ocular assessment was performed within 3 days of laser exposure. A complete ophthalmic evaluation was conducted, including Early Treatment Diabetic Retinopathy Study visual acuity, colour vision, visual fields, intraocular pressure, slit-lamp examination, dilated fundus examination, colour fundus photographs, and ocular coherence tomography. Sixty-four laser strike incidents involving commercial pilots were included. All pilots in the study experienced some degree of immediate ocular irritation or light sensitivity. No definite cases of ocular damage were attributed to laser strikes. No pilot had any functional ocular deficits. Our study revealed that laser strikes on aircraft did not result in permanent visual functional or structural deficits. However, laser strikes cause immediate visual effects, including glare, flash blindness, and ocular irritation that can interfere with a pilot's visual function. Given the widespread accessibility of high-power lasers and the rapid increase in incidents, laser strikes threaten to jeopardize aviation safety unless effective preventative measures are put in place. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  9. Healing activity of laser InGaAlP (660nm in rats Atividade cicatrizante do laser AlGaInP (660nm em ratos

    Directory of Open Access Journals (Sweden)

    Kelly Cristina Borges Tacon

    2011-10-01

    Full Text Available PURPOSE: To evaluate the effect the healing activity of diode laser Indium Gallium Aluminum Phosphorus (InGaAlP ë660nm on healing of surgical wounds in rats. METHODS: Fifty-four female Wistar rats were used, divided into three groups (n=18 and subdivided into three subgroups (n=6 to be studied in 5, 10 and 15th days after surgical procedures. The wound was induced in the dorsal-cervical using punch. The lesions were irradiated on alternate days with InGaAlP laser, the energy densities of 3J/cm² (L3 or 6J/cm² (L6. The control group received no irradiation. At 5, 10 and 15th days after surgery the animals were euthanized and the repair area was removed and histological sections were stained with hematoxylin-eosin and picrossírius. We evaluated macroscopic and histological lesions in the times cited, as well as morphometric analysis of angiogenesis and collagen content. RESULTS: The wound healing activity InGaAlP laser was evidenced by increased angiogenesis group L3 and L6 in relation to control group (CG at the 5th day (p=0.0001 and decreased polymorphonuclear infiltrate and hemorrhage (p=0.045 and p=0.07 respectively in the groups L3 and L6 in relation to control group (GC. On the 10 and 15th days was also observed in groups treated with laser L3 and L6 stimulation was pronounced fibroplasia (p=0.0003 and p=0.034 respectively when compared with the control group (CG. CONCLUSION: The InGaAlP laser acted positively on the healing of skin wounds in rats.OBJETIVO: Avaliar a atividade cicatrizante do laser diodo Alumínio Gálio Índio Fósforo (AlGaInP, ë660nm em feridas cutâneas induzida em ratos. MÉTODOS: Foram utilizados 54 ratos Wistar, fêmeas, divididos em três grupos (n=18 e subdivididos em três subgrupos (n=6 animais para serem estudados no 5, 10 e 15º dias após o procedimento cirúrgico. A ferida foi induzida em região dorso-cervical utilizando punch. As lesões foram irradiadas em dias alternados com laser AlGaInP, nas

  10. LD-pumped actively Q-switched c-cut Nd:GdVO4 self-Raman laser operating at 1166 and 1176 nm

    Science.gov (United States)

    Sun, Xinzhi; Zhang, Xihe; Li, Shutao; Dong, Yuan

    2017-12-01

    A laser diode pumped actively Q-switched c-cut Nd:GdVO4 self-Raman laser is experimentally investigated. Simultaneous pulse outputs at 1166 nm and 1176 nm corresponding to the Raman shifts of 807 and 882 cm-1 are acquired. At the pulse repetition frequency (PRF) of 20 kHz, the maximum output power is 103 mW at 1166 nm with the incident pump power of 2.31 W, while 1176 nm output power reaches 530 mW with the incident pump power of 4.11 W. The maximum output power of Raman laser is 570 mW with the incident pump power of 4.11 W and the PRF of 30 kHz. With the incident pump power of 3.67 W and the PRF of 30 kHz, the highest diode-to-Stokes optical conversion efficiency of 14.9% is obtained with the corresponding average output power of 547 mW.

  11. Infrared laser damage thresholds in corneal tissue phantoms using femtosecond laser pulses

    Science.gov (United States)

    Boretsky, Adam R.; Clary, Joseph E.; Noojin, Gary D.; Rockwell, Benjamin A.

    2018-02-01

    Ultrafast lasers have become a fixture in many biomedical, industrial, telecommunications, and defense applications in recent years. These sources are capable of generating extremely high peak power that can cause laser-induced tissue breakdown through the formation of a plasma upon exposure. Despite the increasing prevalence of such lasers, current safety standards (ANSI Z136.1-2014) do not include maximum permissible exposure (MPE) values for the cornea with pulse durations less than one nanosecond. This study was designed to measure damage thresholds in corneal tissue phantoms in the near-infrared and mid-infrared to identify the wavelength dependence of laser damage thresholds from 1200-2500 nm. A high-energy regenerative amplifier and optical parametric amplifier outputting 100 femtosecond pulses with pulse energies up to 2 mJ were used to perform exposures and determine damage thresholds in transparent collagen gel tissue phantoms. Three-dimensional imaging, primarily optical coherence tomography, was used to evaluate tissue phantoms following exposure to determine ablation characteristics at the surface and within the bulk material. The determination of laser damage thresholds in the near-IR and mid-IR for ultrafast lasers will help to guide safety standards and establish the appropriate MPE levels for exposure sensitive ocular tissue such as the cornea. These data will help promote the safe use of ultrafast lasers for a wide range of applications.

  12. Effects of 532 nm pulsed-KTP laser parameters on vessel ablation in the avian chorioallantoic membrane: implications for vocal fold mucosa.

    Science.gov (United States)

    Broadhurst, Matthew S; Akst, Lee M; Burns, James A; Kobler, James B; Heaton, James T; Anderson, R Rox; Zeitels, Steven M

    2007-02-01

    Selective vascular ablation (photoangiolysis) using pulsed lasers that target hemoglobin is an effective treatment strategy for many vocal fold lesions. However, vessel rupture with extravasation of blood reduces selectivity for vessels, which is frequently observed with the 0.45-ms, 585-nm pulsed dye laser. Previous studies have shown that vessel rupture is the result of vaporization of blood, an event that varies with laser pulse width and pulse fluence (energy per unit area). Clinical observations using a 532-nm wavelength pulsed potassium-titanyl-phosphate (KTP) laser revealed less laser-induced hemorrhage than the pulsed dye laser. This study investigated settings for the pulsed KTP laser to achieve selective vessel destruction without rupture using the avian chorioallantoic membrane under conditions similar to flexible laryngoscopic delivery of the laser in clinical practice. The chick chorioallantoic membrane offers convenient access to many small blood vessels similar in size to those targeted in human vocal fold. Using a 532-nm pulsed KTP laser, pulse width, pulse energy, and working distance from the optical delivery fiber were varied to assess influence on the ability to achieve vessel coagulation without vessel wall rupture. Third-order vessels (n = 135) were irradiated: Energy (471-550 mJ), pulse width (10, 15, 30 ms), and fiber-to-tissue distance (1 mm, 3 mm) were varied systematically. Selective vessel destruction without vessel wall rupture was more often achieved by increasing pulse width, increasing the fiber-to-tissue distance, and decreasing energy. Vessel destruction without rupture was consistently achieved using 15- or 30-ms pulses with a fiber-to-tissue distance of 3 mm (pulse fluence of 13-16 J/cm). This study substantiates our clinical observation that a 532-nm pulsed KTP laser was effective for ablating microcirculation while minimizing vessel wall rupture and hemorrhage.

  13. Use of 1540nm fractionated erbium:glass laser for split skin graft resurfacing: a case study.

    Science.gov (United States)

    Narinesingh, S; Lewis, S; Nayak, B S

    2013-09-01

    The field of laser skin resurfacing has evolved rapidly over the past two decades from ablative lasers, to nonablative systems using near-infrared, intense-pulsed light and radio-frequency systems, and most recently fractional laser resurfacing. Although fractional thermolysis is still in its infancy, its efficacy in in the treatment of skin disorders have been clearly demonstrated. Here we present a case report on the safety and efficacy of a 1540nm erbium:glass laser in the treatment of the waffle pattern of a meshed skin graft in a 38-year-old patient with type V skin in the Caribbean.

  14. Long-pulsed Nd: YAG laser and intense pulse light-755 nm for idiopathic facial hirsutism: A comparative study

    Directory of Open Access Journals (Sweden)

    Arpit Shrimal

    2017-01-01

    Full Text Available Background: Hirsutism means excessive terminal hair growth in a female in male pattern distribution. Perception of hirsutism is subjective. Permanent laser hair reduction is a slow process taking many sessions and tracking of improvement parameters is tedious. Hence, a lot of confusion still exists regarding the type of laser most beneficial for treatment. Aim: The aim of this study was to compare the effectiveness and safety profile of long-pulsed Nd: YAG laser (1064 nm and intense pulse light (IPL-755 nm in management of idiopathic facial hirsutism. Settings and Design: Open-labelled, randomly allocated experimental study. Subjects and Methods: The study included 33 cases of idiopathic facial hirsutism. Patients were randomly divided into Group A, treated with long-pulsed Nd: YAG laser and Group B, treated with IPL-755 for a total of six sessions at 1 month interval. Statistical Analysis: Chi-square test was used in Medcalc® version 9.0 and the test of significance was taken to be P75% reduction in hair after six sessions in Group A was seen in fourteen (93.33% out of fifteen patients, whereas in Group B, it was seen only in three (16.66% out of eighteen patients. In Group A, erythema was seen in 26.67%, perifollicular edema and hyperpigmentation in 13.33% each. In Group B, erythema was seen in 50% patients, perifollicular edema in 16.67% and hyperpigmentation in 38.89% patients. Conclusions: Long-pulsed Nd: YAG Laser (1064 nm is better than IPL-755 nm in terms of safety and effectiveness in the management of idiopathic facial hirsutism.

  15. Smooth silk fibroin nanofilm deposited by 1064-nm pulsed laser beam from an opaque target

    International Nuclear Information System (INIS)

    Nozaki, R.; Nakayama, S.; Senna, M.

    2013-01-01

    In an attempt to prepare smooth nanostructured thin films of silk fibroin (SF) by near-infrared (NIR) pulsed laser deposition, an opaque target was prepared from an emulsified aqueous solution of SF. Upon irradiation of 1064-nm pulsed laser beam at its fluence 5 J/cm 2 , a thin film of SF was deposited on the Si(100) substrate with its root-mean-square surface roughness, 0.37 nm, smoother than those obtained from a compressed target of SF powders by approximately an order of magnitude. The attainment of an extra-smooth film from the opaque target was discussed in terms of multiple Mie scattering of the incident NIR beam, leading to an increase in the plasma density, intensified optical breakdown, ablation of better dispersed SF molecular units, and a film with more intensive intermolecular cross-linking. - Highlights: • Thin film of silk fibroin with its RMS surface roughness, R rms , 0.37 nm was obtained. • The use of a target from an emulsified solution of SF was the key issue. • Mechanism involved was elucidated in terms of enhanced Mie scattering

  16. Cyclotron resonant gas breakdown with a 1.22-nm 13CH3F laser

    International Nuclear Information System (INIS)

    Hacker, M.P.; Lax, B.; Metz, R.N.; Temkin, R.J.

    1979-01-01

    Cyclotron-resonant laser-induced gas breakdown has been studied for the first time in the transverse geometry, using 1.222-nm 13 CH 3 F laser radiation propagating perpendicular to the magnetic field axis. The line shape of absorbed laser radiation versus magnetic field near electron cyclotron resonance (87.75 kG) indicates a strong dependence of the line shape on the focused laser intensity. This dependence is not predicted by the standard equilibrium theory of high-frequency gas breakdown in a magnetic field. We have developed an analytic theory to explain the observed line shapes. The theory takes into account the laser propagation characteristics, in particular that there is nonuniform ionization due to strong resonant absorption of the laser radiation in a length comparable to or shorter than that of the laser focal volume. The transverse geometry simplifies the theoretical analysis because the observed line shapes are not significantly affected by Doppler broadening. Extensive data have been obtained on the fraction of laser pulse energy absorbed in the gas breakdown volume as a function of magnetic field, helium gas pressure, and incident laser pulse energy. Good quantitative agreement is obtained between the observed laser pulse absorption line shapes and the nonuniform ionization theory

  17. Integrated cooling-vacuum-assisted 1540-nm erbium:glass laser is effective in treating mild-to-moderate acne vulgaris.

    Science.gov (United States)

    Politi, Y; Levi, A; Enk, C D; Lapidoth, M

    2015-12-01

    Acne treatment by a mid-infrared laser may be unsatisfactory due to deeply situated acne-affected sebaceous glands which serve as its target. Skin manipulation by vacuum and contact cooling may improve laser-skin interaction, reduce pain sensation, and increase overall safety and efficacy. To evaluate the safety and efficacy of acne treatment using an integrated cooling-vacuum-assisted 1540-nm erbium:glass laser, a prospective interventional study was conducted. It included 12 patients (seven men and five women) suffering from mild-to-moderate acne vulgaris. The device utilizes a mid-infrared 1540-nm laser (Alma Lasers Ltd. Caesarea, Israel), which is integrated with combined cooling-vacuum-assisted technology. An acne lesion is initially manipulated upon contact by a vacuum-cooling-assisted tip, followed by three to four stacked laser pulses (500-600 mJ, 4 mm spot size, and frequency of 2 Hz). Patients underwent four to six treatment sessions with a 2-week interval and were followed-up 1 and 3 months after the last treatment. Clinical photographs were taken by high-resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists, and results were graded on a scale of 0 (exacerbation) to 4 (76-100 % improvement). Patients' and physicians' satisfaction was also recorded. Pain perception and adverse effects were evaluated as well. All patients demonstrated a moderate to significant improvement (average score of 3.6 and 2.0 within 1 and 3 months, respectively, following last treatment session). No side effects, besides a transient erythema, were observed. Cooling-vacuum-assisted 1540-nm laser is safe and effective for the treatment of acne vulgaris.

  18. Design of the nickel-like tin x-ray laser at 12.0 nm

    International Nuclear Information System (INIS)

    Yan Fei; Zhang Jie; Lu Xin; Zhong, Jia Y.

    2005-01-01

    The effects of the drive laser intensity, pulse duration, and pulse configuration on the performance of the Ni-like Sn x-ray laser at 12.0 nm (4d→4p, J=0→1) are investigated with use of a one-dimensional hydrodynamic code coupled with an atomic physics code. High gain operation is predicted for the optimized drive pulse configuration. The effects of refraction and saturation on the propagation of the x-ray laser in the plasma medium are also investigated by use of a two-dimensional ray-tracing code. The results show that the refraction plays an important role. The saturated output with an effective gain product length of 17.88 can be obtained for an ∼0.40-cm-long plasma column by use of optimized parameters

  19. Morphological alterations of radicular dentine pretreated with different irrigating solutions and irradiated with 980-nm diode laser.

    Science.gov (United States)

    Alfredo, Edson; Souza-Gabriel, Aline E; Silva, Silvio Rocha C; Sousa-Neto, Manoel D; Brugnera-Junior, Aldo; Silva-Sousa, Yara T C

    2009-01-01

    The topographical features of intraradicular dentine pretreated with sodium hypochlorite (NaOCl) or ethylenediamine tetraacetic acid (EDTA) followed by diode laser irradiation have not yet been determined. To evaluate the alterations of dentine irradiated with 980-nm diode laser at different parameters after the surface treatment with NaOCl and EDTA. Roots of 60 canines were biomechanically prepared and irrigated with NaOCl or EDTA. Groups were divided according to the laser parameters: 1.5 W/CW; 1.5 W/100 Hz; 3.0 W/CW; 3.0 W/100 Hz and no irradiation (control). The roots were splited longitudinally and analyzed by scanning electron microscopy (SEM) in a quali-quatitative way. The scores were submitted to two-way Kruskal-Wallis and Dunn's tests. The statistical analysis demonstrated that the specimens treated only with NaOCl or EDTA (control groups) were statistically different (P laser-irradiated specimens, regardless of the parameter setting. The specimens treated with NaOCl showed a laser-modified surface with smear layer, fissures, and no visible tubules. Those treated with EDTA and irradiated by laser presented absence of smear layer, tubules partially exposed and melting areas. The tested parameters of 980-nm diode laser promoted similar alterations on dentine morphology, dependent to the type of surface pretreatment. Copyright 2008 Wiley-Liss, Inc.

  20. A 223-nm KrCl excimer laser on a He-Kr-HCl mixture

    International Nuclear Information System (INIS)

    Razhev, A M; Zhupikov, A A; Kargapol'tsev, E S

    2004-01-01

    The results of experimental studies of the parameters of a 223-nm electric-discharge KrCl excimer laser on a He-Kr-HCl mixture depending on the excitation conditions and the composition of the active gaseous medium are presented. To achieve the maximum values of the output energy and the efficiency of the KrCl laser on mixtures with buffer gaseous helium, an excitation system was used that included a circuit with an LC inverter with a high-voltage switch based on an RU-65 spark gap. An output energy of 320 mJ with an efficiency of 0.5% relative to the energy stored in the capacitors is obtained in a KrCl laser with an active medium based on the buffer He gas at a charging voltage of 30 kV. Radiation pulses with a duration of 22±1 ns and a pulse power of 15 MW are obtained. (lasers)

  1. [A Methane Detection System Using Distributed Feedback Laser at 1 654 nm].

    Science.gov (United States)

    Li, Bin; Liu, Hui-fang; He, Qi-xin; Zhai, Bing; Pan, Jiao-qing; Zheng, Chuan-tao; Wang, Yi-ding

    2016-01-01

    A methane (CH4) detection system based on tunable diode laser absorption spectroscopy (TDLAS) technique was experimentally demonstrated. A distributed feedback (DFB) laser around 1 654 nm, an open reflective sensing probe and two InGaAs photodiodes were adopted in the system. The electrical part of the system mainly includes the laser temperature control & modulation module and the orthogonal lock-in amplifier module. Temperature and spectrum tests on the DFB laser indicate that, the laser temperature fluctuation can be limited to the range of -0.02-0.02 degrees C, the laser's emitting wavelength varies linearly with the temperature and injection current, and also good operation stability of the laser was observed through experiments. Under a constant working temperature, the center wavelength of the laser is varied linearly by adjusting the driving current. Meanwhile, a 5 kHz sine wave signal and a 10 Hz saw wave signal were provided by the driving circuit for the harmonic extraction purpose. The developed orthogonal lock-in amplifier can extract the If and 2f harmonic signals with the extraction error of 3.55% and 5% respectively. By using the open optical probe, the effective optical pass length was doubled to 40 cm. Gas detection experiment was performed to derive the relation between the harmonic amplitude and the gas concentration. As the concentration increases from 1% to 5%, the amplitudes of the 1f harmonic and the 2f harmonic signal were obtained, and good linear ration between the concentration and the amplitude ratio was observed, which proves the normal function of the developed detection system. This system is capable to detect other trace gases by using relevant DFB lasers.

  2. First demonstration of InGaP/InAlGaP based orange laser emitting at 608 nm

    KAUST Repository

    Majid, Mohammed Abdul; Al-Jabr, Ahmad; Oubei, Hassan M.; Alias, Mohd Sharizal; Anjum, Dalaver H.; Ng, Tien Khee; Ooi, Boon S.

    2015-01-01

    The fabrication of orange-emitting semiconductor laser on interdiffused InGaP/InAlGaP structure is reported. The lasers lased at 22°C at a wavelength as short as 608 nm with threshold current density of 3.4 KAcm −2 and a maximum output power of ∼46

  3. First demonstration of InGaP/InAlGaP based orange laser emitting at 608 nm

    KAUST Repository

    Majid, Mohammed Abdul

    2015-06-26

    The fabrication of orange-emitting semiconductor laser on interdiffused InGaP/InAlGaP structure is reported. The lasers lased at 22°C at a wavelength as short as 608 nm with threshold current density of 3.4 KAcm −2 and a maximum output power of ∼46 mW. This is the shortest wavelength electrically pumped semiconductor laser emission from the InGaP/InAlGaP structure.

  4. Safety and Efficacy of a 1550nm/1927nm Dual Wavelength Laser for the Treatment of Photodamaged Skin.

    Science.gov (United States)

    Narurkar, Vic A; Alster, Tina S; Bernstein, Eric F; Lin, Tina J; Loncaric, Anya

    2018-01-01

    BACKGROUND: Fractional photothermolysis (FP) is a popular treatment option for photodamaged skin and addresses shortcomings of ablative skin resurfacing and nonablative dermal remodeling. Previous studies have demonstrated that FP using the 1550nm wavelength has led to improvement of ultrastructural changes and clinical effects associated with photodamaged skin in the deeper dermal structures, while treatment with the 1927nm wavelength has shown clinical effects in the superficial dermis. Both wavelengths produce precise microscopic treatment zones (MTZs) in the skin. The two wavelengths used in combination may optimize the delivery of fractional nonablative resurfacing intended for dermal and epidermal coagulation of photodamage skin. OBJECTIVES: To evaluate the safety and efficacy of a 1550/1927 Laser System (Fraxel Dual, Solta), using both 1550nm and 1927nm wavelengths in combination for treatment of facial and non-facial photodamage. METHODS: Prospective, multi-center, post-market study in subjects with clinically identifiable photodamage (N=35) (Fitzpatrick skin types I-IV). Both 1550nm and 1927nm wavelengths were used at each treatment visit. Investigator assessment of the affected area(s) occurred at one week, one month and 3 months after a series of up to four treatments. Severity of adverse events (AEs) were assessed using a 4-point scale (where 0=none and 3=marked). Assessments included erythema, edema, hyperkeratosis, hyper- and hypo-pigmentation, scarring, itchiness, dryness, and flaking. Severity of photoaging, fine and coarse wrinkling, mottled hyperpigmentation, sallowness, and tactile roughness at baseline was assessed using the same scale. Investigators and subjects assessed overall appearance of photodamage and pigmentation based on a 5-point quartile improvement scale at all follow-up visits (where 0=no improvement and 4=very significant improvement [76%-100%]). RESULTS: There was a positive treatment effect at all study visits, with moderate

  5. Sharpening of the 6.8 nm peak in an Nd:YAG laser produced Gd plasma by using a pre-formed plasma

    Directory of Open Access Journals (Sweden)

    Yong Tian

    2016-03-01

    Full Text Available For effective use of a laser-produced-plasma (LPP light source, an LPP is desired to emit a narrow spectral peak because the reflection spectrum of multilayer mirrors for guiding emission from the source is very narrow. While a Gd plasma has been studied extensively as an extreme ultraviolet (EUV light source at around 6.8 nm, where La/B4C multilayer is reported to have a high reflectivity with a bandwidth of about 0.6 %, all previous works using an Nd:YAG laser reported very broad spectra. This paper reports the first narrowing of the 6.8 nm peak in the case of using an Nd:YAG laser to generate a Gd plasma by using a pre-pulse. The best peak narrowing is observed when a pre-formed plasma is heated by a 1064 nm main laser pulse with a duration of 10 ns at the irradiation density of 4x 1011 W/cm2 at a delay time of 50 ns after the pre-pulse irradiation. The observed spectral width of about 0.3 nm is about one fifth of the value for no pre-formed plasma. The peak wavelength of the 6.8 nm band shifted to a longer wavelength side and the peak was broadened both for lower and higher laser irradiation density. It is discussed that this robustness of the peak position of the 6.8 nm Gd peak against temperature change is suitable to achieve a narrow bandwidth from an LPP generated on solid. The observed spectra are compared with those previously reported in various conditions.

  6. 205 nm continuous-wave laser: application to the measurement of the Lamb shift in hydrogen; Laser continu a 205 nm: application a la mesure du deplacement de lamb dans l'hydrogene

    Energy Technology Data Exchange (ETDEWEB)

    Bourzeix, S

    1995-01-15

    The subject of this thesis is the construction of an experimental set-up, and in particular of a tunable continuous-wave laser at 205 nm, for the measurement of the ground state Lamb shift in atomic hydrogen. Chapter 1 deals with the Lamb shift from a historical point of view, and with the interest of its measurement, for metrology and test of quantum electrodynamics. Chapter 2 is devoted to the theory of the hydrogen atom. The principle of the experiment is based on the comparison of two frequencies which are in a ratio of 4: those of the two-photon transitions of 2S-6S or 2S-6D and 1S-3S. Chapter 3 describes the experimental set-up used to measure the 2S-6D transition which is excited by a titanium-sapphire laser at 820 nm. The 205 nm light required to excite the 1S-3S transition is generated by two frequency-doubling of the titanium-sapphire laser, made in non-linear crystals placed in enhancement cavities. Chapter 4 is entirely devoted to the frequency-doubling. After a recall of non-linear optics, the enhancement cavities are described in detail, as well as the results we achieved. At last chapter 5 describes the research for a signal on the 1S-3S transition: the construction of a ground state atomic beam, and the development of the detection system. This work has led to a preliminary measurement of the ground state Lamb shift in atomic hydrogen: L(1S) = 8172.850 (174) MHz whose result is in very good agreement with both the previous measurements and the most recent theoretical results. (author)

  7. Spectral beam combining of a 980 nm tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Ostendorf, Ralf

    2010-01-01

    We demonstrate spectral beam combining of a 980 nm tapered diode laser bar. The combined beam from 12 tapered emitters on the bar yielded an output power of 9.3 W at 30 A of operating current. An M2 value of 5.3 has been achieved along the slow axis. This value is close to that of a free running...... single tapered emitter on the bar at the same current level. The overall spectral beam combining efficiency was measured to be 63%....

  8. S100a8/NF-κB signal pathway is involved in the 800-nm diode laser-induced skin collagen remodeling.

    Science.gov (United States)

    Ren, Xiaolin; Ge, Minggai; Qin, Xiaofeng; Xu, Peng; Zhu, Pingya; Dang, Yongyan; Gu, Jun; Ye, Xiyun

    2016-05-01

    The 800-nm diode laser is widely used for hair removal and also promotes collagen synthesis, but the molecular mechanism by which dermis responses to the thermal damage induced by the 800-nm diode laser is still unclear. Ten 2-month-old mice were irradiated with the 800-nm diode laser at 20, 40, and 60 J/cm(2), respectively. Skin samples were taken for PCR, Western blot analysis, and histological study at day 3 or 30 after laser irradiation. The expression of S100a8 and its two receptors (advanced glycosylation end product-specific receptor, RAGE and toll-like receptor 4, TRL4) was upregulated at day 3 after laser treatments. P-p65 levels were also elevated, causing the increase of cytokine (tumor necrosis factor, TNF-α and interleukin 6, IL-6) and MMPs (MMP1a, MMP9). At day 30, PCR and Western blot analysis showed significant increase of type I and III procollagen in the dermis treated with laser. Importantly, skin structure was markedly improved in the laser-irradiated skin compared with the control. Thus, it seemed that S100a8 upregulation triggered NF-κB signal pathway through RAGE and TLR4, responding to laser-induced dermis wound healing. The involvement of the NF-κB pathway in MMP gene transcription promoted the turnover of collagen in the skin, accelerating new collagen synthesis.

  9. Continuous-wave laser operation at 743 and 753 nm based on a diode-pumped c-cut Pr:YAlO3 crystal

    Science.gov (United States)

    Lin, Xiuji; Huang, Xiaoxu; Liu, Bin; Xu, Bin; Xu, Huiying; Cai, Zhiping; Xu, Xiaodong; Li, Dongzhen; Liu, Jian; Xu, Jun

    2018-02-01

    We report on blue-diode-pumped continuous-wave Pr:YAlO3 (YAP) crystal lasers. Using a b-cut sample, a maximum output power of 181 mW is achieved at ∼747 nm with slope efficiency of 12.7% with respect to the absorbed power. Using a c-cut sample, a dual-wavelength laser at ∼743 and ∼753 nm is obtained with a total maximum output power of 72 mW by using the blue diode pumping, for the first time to our knowledge. These laser emissions are all linearly polarized and M2 factors of these output laser beams are also measured. YAP is experimentally verified to be one of effective oxide hosts for Pr-doped visible laser operation besides its fluoride counterparts.

  10. Effects of Q-switched and long-pulsed 1064 nm Nd:YAG laser on enlarged facial pores.

    Science.gov (United States)

    Lee, Chang Nam; Kim, You Jeong; Lee, Hyun Seung; Kim, Hei Sung

    2009-12-01

    'Enlarged facial pore' is a subjective term, which is not clearly defined but often complained by many. A diverse range of treatments are used though evidence of efficacy remains largely anecdotal. We report a series of nine patients who underwent a split face trial with Q-switched 1064 nm Nd:YAG and long-pulsed 1064 nm Nd:YAG laser to treat enlarged facial pores.

  11. Antimicrobial action of minocycline microspheres versus 810-nm diode laser on human dental plaque microcosm biofilms.

    Science.gov (United States)

    Song, Xiaoqing; Yaskell, Tina; Klepac-Ceraj, Vanja; Lynch, Michael C; Soukos, Nikolaos S

    2014-02-01

    The purpose of this study is to investigate the antimicrobial effects of minocycline hydrochloride microspheres versus infrared light at 810 nm from a diode laser on multispecies oral biofilms in vitro. These biofilms were grown from dental plaque inoculum (oral microcosms) and were obtained from six systemically healthy individuals with generalized chronic periodontitis. Multispecies biofilms were derived using supra- and subgingival plaque samples from mesio-buccal aspects of premolars and molars exhibiting probing depths in the 4- to 5-mm range and 1- to 2-mm attachment loss. Biofilms were developed anaerobically on blood agar surfaces in 96-well plates using a growth medium of prereduced, anaerobically sterilized brain-heart infusion with 2% horse serum. Minocycline HCl 1 mg microspheres were applied on biofilms on days 2 and 5 of their development. Biofilms were also exposed on days 2 and 5 of their growth to 810-nm light for 30 seconds using a power of 0.8 W in a continuous-wave mode. The susceptibility of microorganisms to minocycline or infrared light was evaluated by a colony-forming assay and DNA probe analysis at different time points. At all time points of survival assessment, minocycline was more effective (>2 log10 colony-forming unit reduction) than light treatment (P plaque pathogens to light, and it was not possible after treatment with minocycline due to lack of bacterial growth. The cumulative action of minocycline microspheres on multispecies oral biofilms in vitro led to enhanced killing of microorganisms, whereas a single exposure of light at 810 nm exhibited minimal and non-selective antimicrobial effects.

  12. Advances in 750 nm VECSELs (Conference Presentation)

    Science.gov (United States)

    Saarinen, Esa J.; Ranta, Sanna; Lyytikäinen, Jari; Saarela, Antti; Sirbu, Alexei; Iakovlev, Vladimir; Kapon, Eli; Guina, Mircea

    2017-03-01

    Lasers operating in the transmission window of tissue at wavelengths between 700 and 800 nm are needed in numerous medical and biomedical applications, including photodynamic therapy and fluorescence microscopy. However, the performance of diode lasers in this spectral range is limited by the lack of appropriate compound semiconductors. Here, we review our recent research on 750 nm VECSELs. Two approaches to reaching the 750 nm wavelength will be discussed. The first approach relies on intra-cavity frequency doubling a wafer-fused 1500 nm VECSEL. The VECSEL gain chip comprises a GaAs-based DBR and an InP-based gain section, which allows for optical pumping with low-cost commercial diodes at 980 nm. With this scheme we have achieved watt-level output powers and tuning of the laser wavelength over a 40 nm band at around 750 nm. The second approach is direct emission at 750 nm using the AlGaAs/GaAs material system. In this approach visible wavelengths are required for optical pumping. However, the consequent higher costs compared to pumping at 980 nm are mitigated by the more compact laser setup and prospects of doubling the frequency to the ultraviolet range.

  13. Bragg gratings inscription in step-index PMMA optical fiber by femtosecond laser pulses at 400 nm

    Science.gov (United States)

    Hu, X.; Kinet, D.; Chah, K.; Mégret, P.; Caucheteur, C.

    2016-05-01

    In this paper, we report photo-inscription of uniform Bragg gratings in trans-4-stilbenemethanol-doped photosensitive step-index polymer optical fiber. Gratings were produced at ~1575 nm by the phase mask technique with a femtosecond laser emitting at 400 nm with different average optical powers (8 mW, 13 mW and 20 mW). The grating growth dynamics in transmission were monitored during the manufacturing process, showing that the grating grows faster with higher power. Using 20 mW laser beam power, the reflectivity reaches 94 % (8 dB transmission loss) in 70 seconds. Finally, the gratings were characterized in temperature in the range 20 - 45 °C. The thermal sensitivity has been computed equal to - 86.6 pm/°C.

  14. Amniotic membrane welded to contact lens by 1470-nm diode laser:a novel method for sutureless amniotic membrane transplantation

    Directory of Open Access Journals (Sweden)

    Rifat Rasier

    2014-12-01

    Full Text Available AIM: To avoid the side effects of the suture usage by welding amniotic membrane (AM to contact lens (CL with laser.METHODS:AM was taken from pregnant women and cleaned from blood clots with sterile phosphate-buffered physiological saline solution which included antibiotics. Stromal side of the AM was spread inside of the CL and it was welded to CL by 1470 nm diode laser. 600 μm diameter fiber tip of the laser was contacted with the epithelial side of the AM from 4 separate points. After welding excess amniotic membrane around the CL was cut with a scalpel.RESULTS:Stromal side of the AM was spread inside of the CL and then with laser fiber, different power levels and exposure times were applied on the epithelium of AM and 340 mW for seven seconds was found optimal. CL and AM attached with the spot welding effect in 4 points by touching fiber tip. CL-AM welded complex did not separated from each other while holding AM that extend beyond the CL with the help of two forceps.CONCLUSION:As a conclusion, it was aimed in this study to achieve the success of the conventional amniotic membrane transplantation (AMTwith the easiness of applying a CL and to avoid risks and side effects of corneal or conjunctival suturing. The results showed that the application of the CL–AM complex will be as easy as the application of a CL and lasts shortly.

  15. 75 W 40% efficiency single-mode all-fiber erbium-doped laser cladding pumped at 976 nm.

    Science.gov (United States)

    Kotov, L V; Likhachev, M E; Bubnov, M M; Medvedkov, O I; Yashkov, M V; Guryanov, A N; Lhermite, J; Février, S; Cormier, E

    2013-07-01

    Optimization of Yb-free Er-doped fiber for lasers and amplifiers cladding pumped at 976 nm was performed in this Letter. The single-mode fiber design includes an increased core diameter of 34 μm and properly chosen erbium and co-dopant concentrations. We demonstrate an all-fiber high power laser and power amplifier based on this fiber with the record slope efficiency of 40%. To the best of our knowledge, the achieved output power of 75 W is the highest power reported for such lasers.

  16. Characterization and standardization of a thermoluminescent dosimetric system to ultraviolet and laser radiation using CaSO4:Dy

    International Nuclear Information System (INIS)

    Grossi, Fabio Henrique

    2002-01-01

    The photo transferred thermoluminescence (PTTL) was used to characterize a dosimetric system to the laser and ultraviolet radiation. Dysprosium activated calcium sulphate samples (CaSO 4 :Dy) used are produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN) and have proved been an excellent dosimetric material for non ionizing radiation. PTTL signal was studied for UV radiation detection in the 220 to 450 nm range and for laser radiation in the 193 to 1.160 nm range. The samples presented more sensibility to the 193, 250, 310 and 337 nm wavelengths and no sensibility to infrared region. The samples presented linear PTTL in function of radiant exposure, excitation gamma dose in the range between 5 and 100 Gy and laser beam diameter between 2 and 6 nm. Another parameters studied were the angular dependence, UV lower exposure limit and PTTL signal optical fading. Spread laser radiation analysis was performed in the Ophthalmologic Department of Universidade Federal de Sao Paulo (UNIFESP) surgical center, showing that samples positioned as far as 4 m from laser source are sensitized to the laser radiation, as well as evaluating the laser exposure received by workers of medical area. A method to send the samples by mail was developed to the studies performed in the UNIFESP. (author)

  17. Angular distributions of emitted particles by laser ablation of silver at 355 nm

    DEFF Research Database (Denmark)

    Svendsen, Winnie Edith; Schou, Jørgen; Hansen, T.

    1998-01-01

    The angular distribution of laser ablated silver in vacuum has been measured in situ with an array of quartz-crystal microbalances. The silver surface was irradiated by ns pulses from a Nd:YAG laser operating at 355 nm for fluences ranging from 0.7 J/cm2 to 8 J/cm2. The distribution is strongly...... peaked in the forward direction corresponding to cosp/, where p varies from 5 to 12 for the largest beam spot, but is less peaked for the smallest beam spots. The total collected yield of ablated atoms is about 221015 Ag atoms per pulse for the highest pulse energies....

  18. High average power 1314 nm Nd:YLF laser, passively Q-switched with V:YAG

    CSIR Research Space (South Africa)

    Botha, RC

    2013-03-01

    Full Text Available A 1314 nm Nd:YLF laser was designed and operated both CW and passively Q-switched. Maximum CW output of 10.4 W resulted from 45.2 Wof incident pump power. Passive Q-switching was obtained by inserting a V:YAG saturable absorber in the cavity...

  19. Diode-end-pumped Tm:GdVO4 laser operating at 1818 and 1915 nm

    CSIR Research Space (South Africa)

    Esser, MJD

    2009-10-01

    Full Text Available wavelengths. We therefore embarked on ac- curately measuring absorption spectra of Tm:GdVO4 laser crystals at both 0.8 (pump band) and at 1.9 µm (emission band). The measurements were conducted with a Cary 5000 spectrometer with resolution set to 1 nm...

  20. In Vitro Evaluation of Dentin Hydraulic Conductance After 980 nm Diode Laser Irradiation.

    Science.gov (United States)

    Rizzante, Fabio A P; Maenosono, Rafael M; Duarte, Marco A H; Furuse, Adilson Y; Palma-Dibb, Regina G; Ishikiriama, Sérgio K

    2016-03-01

    Dentin hypersensitivity treatments are based on the physical obliteration of the dentinal tubules to reduce hydraulic conductance. The aim of the present study is to evaluate the hydraulic conductance of bovine root dentin after irradiation with a 980-nm diode laser, with or without associated fluoride varnish. Sixty bovine root dentin specimens were divided into six groups (n = 10 in each group): G1, G3, and G5 (0.5 W, 0.7 W, and 1 W diode laser, respectively); G2, G4, and G6 (fluoride varnish application + 0.5 W, 0.7 W, and 1 W diode laser, respectively). The dentin hydraulic conductance was evaluated at four time periods with a fluxmeter: 1) with smear layer, 2) after 37% phosphoric acid etching, 3) after the treatments, and 4) after 6% citric acid challenge. After the dentinal fluid flow measurements, specimens were also evaluated for mineral composition using energy dispersive X-ray spectroscopy (EDS). Analysis demonstrated a better result with increased irradiation power (P diode laser irradiation was associated with the application of fluoride varnish (P laser irradiation, the 1 W group was superior when compared with the 0.5 W and 0.7 W irradiated groups immediately after treatment (P laser treatments. Laser irradiation of exposed dentin promoted significant reduction in the dentin hydraulic conductance, mainly with higher energy densities and association with fluoride varnish.

  1. Characteristics of the Single-Longitudinal-Mode Planar-Waveguide External Cavity Diode Laser at 1064 nm

    Science.gov (United States)

    Numata, Kenji; Alalusi, Mazin; Stolpner, Lew; Margaritis, Georgios; Camp, Jordan; Krainak, Michael

    2014-01-01

    We describe the characteristics of the planar-waveguide external cavity diode laser (PW-ECL). To the best of our knowledge, it is the first butterfly-packaged 1064 nm semiconductor laser that is stable enough to be locked to an external frequency reference. We evaluated its performance from the viewpoint of precision experiments. Using a hyperfine absorption line of iodine, we suppressed its frequency noise by a factor of up to 104 at 10 mHz. The PWECL's compactness and low cost make it a candidate to replace traditional Nd:YAG nonplanar ring oscillators and fiber lasers in applications that require a single longitudinal mode.

  2. Passively mode-locked high power Nd:GdVO4 laser with direct in-band pumping at 912 nm

    Science.gov (United States)

    Nadimi, Mohammad; Waritanant, Tanant; Major, Arkady

    2018-01-01

    We report on the first semiconductor saturable absorber mirror mode-locked Nd:GdVO4 laser directly diode-pumped at 912 nm. The laser generated 10.14 W of averaged output power at 1063 nm with the pulse width of 16 ps at the repetition rate of 85.2 MHz. The optical-to-optical efficiency and slope efficiency in the mode-locked regime were calculated to be 49.6% and 67.4% with respect to the absorbed pump power, respectively. Due to the low quantum defect pumping the output power was limited only by the available pump power.

  3. Effects of cryogen spray cooling and high radiant exposures on selective vascular injury during laser irradiation of human skin.

    Science.gov (United States)

    Tunnell, James W; Chang, David W; Johnston, Carol; Torres, Jorge H; Patrick, Charles W; Miller, Michael J; Thomsen, Sharon L; Anvari, Bahman

    2003-06-01

    Increasing radiant exposure offers a means to increase treatment efficacy during laser-mediated treatment of vascular lesions, such as port-wine stains; however, excessive radiant exposure decreases selective vascular injury due to increased heat generation within the epidermis and collateral damage to perivascular collagen. To determine if cryogen spray cooling could be used to maintain selective vascular injury (ie, prevent epidermal and perivascular collagen damage) when using high radiant exposures (16-30 J/cm2). Observational study. Academic hospital and research laboratory. Twenty women with normal abdominal skin (skin phototypes I-VI). Skin was irradiated with a pulsed dye laser (wavelength = 585 nm; pulse duration = 1.5 milliseconds; 5-mm-diameter spot) using various radiant exposures (8-30 J/cm2) without and with cryogen spray cooling (50- to 300-millisecond cryogen spurts). Hematoxylin-eosin-stained histologic sections from each irradiated site were examined for the degree of epidermal damage, maximum depth of red blood cell coagulation, and percentage of vessels containing perivascular collagen coagulation. Long cryogen spurt durations (>200 milliseconds) protected the epidermis in light-skinned individuals (skin phototypes I-IV) at the highest radiant exposure (30 J/cm2); however, epidermal protection could not be achieved in dark-skinned individuals (skin phototypes V-VI) even at the lowest radiant exposure (8 J/cm2). The red blood cell coagulation depth increased with increasing radiant exposure (to >2.5 mm for skin phototypes I-IV and to approximately 1.2 mm for skin phototypes V-VI). In addition, long cryogen spurt durations (>200 milliseconds) prevented perivascular collagen coagulation in all skin types. Cryogen spurt durations much longer than those currently used in therapy (>200 milliseconds) may be clinically useful for protecting the epidermis and perivascular tissues when using high radiant exposures during cutaneous laser therapies

  4. Effect of low-level pulsed laser 890-nm on lumbar spondylolisthesis: a case report

    Science.gov (United States)

    Mortazavi, Seyed M. J.; Afsharpad, Mitra; Djavid, Gholam-reza E.

    2002-10-01

    Objective: Evaluating the effectiveness of low-level laser therapy (LLLT) in alleviating the symptoms of lumbar spondylolisthesis. Materials and Methods: Laser was irradiated for 2 mm at six symmetric points along the lumbosacral spine and 5 points along the referred point ofpain, six times a week for 2 weeks (890 nm; 8 J/cm2; pulsed at 1500 Hz). Perception of benefit, level of function was assessed by the Oswestry disability index, lumbar mobility range of motion and low back pain intensity. Results and Discussion: Results showed a complete reduction in pain and improvement in function in the patient. This case report suggests that low-level laser therapy (LLLT) could play a role in conservative management of low-grade lumbar spondylolisthesis.

  5. Paramecium: a promising non-animal bioassay to study the effect of 808 nm infrared diode laser photobiomodulation.

    Science.gov (United States)

    Amaroli, Andrea; Parker, Steven; Dorigo, Gianluca; Benedicenti, Alberico; Benedicenti, Stefano

    2015-01-01

    Photobiostimulation and photobiomodulation (PBM) are terms applied to the manipulation of cellular behavior using low intensity light sources, which works on the principle of inducing a biological response through energy transfer. The aim of this investigation was to identify a laboratory assay to test the effect of an infrared diode laser light (808 nm) on cell fission rate. Sixty cells of Paramecium primaurelia were divided in two groups of 30. The first group (test group) was irradiated, at a temperature of 24°C, for 50 sec by a 808 nm diode laser with a flat top handpiece [1 cm of spot diameter, 1 W in continuous wave (CW), 50 sec irradiation time, 64 J/cm(2) of fluence]. The second group (control group) received no laser irradiation. All cells were transferred onto a depression slide, fed, and incubated in a moist chamber at a temperature of 24°C. The cells were exposed and monitored for 10 consecutive fission rates. Changes in temperature and pH were also evaluated. The exposed cells had a fission rate rhythm faster than the control cells, showing a binary fission significantly (pParamecium's lettuce infusion medium were observed. The 808 nm infrared diode laser light, at the irradiation parameters used in our work, results in a precocious fission rate in P. primaurelia cells, probably through an increase in metabolic activity, secondary to an energy transfer.

  6. Parametric Raman crystalline anti-Stokes laser at 503 nm with collinear beam interaction at tangential phase matching

    Science.gov (United States)

    Smetanin, S. N.; Jelínek, M.; Kubeček, V.

    2017-07-01

    Stimulated-Raman-scattering in crystals can be used for the single-pass frequency-conversion to the Stokes-shifted wavelengths. The anti-Stokes shift can also be achieved but the phase-matching condition has to be fulfilled because of the parametric four-wave mixing process. To widen the angular-tolerance of four-wave mixing and to obtain high-conversion-efficiency into the anti-Stokes, we developed a new scheme of the parametric Raman anti-Stokes laser at 503 nm with phase-matched collinear beam interaction of orthogonally-polarized Raman components in calcite oriented at the phase-matched angle under 532 nm 20 ps laser excitation. The excitation laser beam was split into two orthogonally-polarized components entering the calcite at the certain incidence angles to fulfill the nearly collinear phase-matching and also to compensate walk-off of extraordinary waves for collinear beam interaction. The phase matching of parametric Raman interaction is tangential and insensitive to the angular mismatch if the Poynting vectors of the biharmonic pump and parametrically generated (anti-Stokes) waves are collinear. For the first time it allows to achieve experimentally the highest conversion efficiency into the anti-Stokes wave (503 nm) up to 30% from the probe wave and up to 3.5% from both pump and probe waves in the single-pass picosecond parametric calcite Raman laser. The highest anti-Stokes pulse energy was 1.4 μJ.

  7. 980 nm diode lasers in oral and facial practice: current state of the science and art.

    Science.gov (United States)

    Desiate, Apollonia; Cantore, Stefania; Tullo, Domenica; Profeta, Giovanni; Grassi, Felice Roberto; Ballini, Andrea

    2009-11-24

    To evaluate the safety and efficacy of a 980 nm diode laser for the treatment of benign facial pigmented and vascular lesions, and in oral surgery. 20 patients were treated with a 980 nm diode laser. Oral surgery: 5 patients (5 upper and lower frenulectomy). Fluence levels were 5-15 J/cm(2); pulse lengths were 20-60 ms; spot size was 1 mm. Vascular lesions: 10 patients (5 small angiomas, 5 telangiectases). Fluences were 6-10 J/cm(2); pulse lengths were 10-50 ms; spot size was 2 mm. In all cases the areas surrounding the lesions were cooled. Pigmented lesions: 5 patients (5 keratoses). All the lesions were evaluated by dermatoscopy before the treatment. Fluence levels were 7-15 J/cm(2); pulse lengths were 20-50 ms; spot size was 1 mm. All the patients were followed at 1, 4 and 8 weeks after the procedure. Healing in oral surgery was within 10 days. The melanoses healed completely within four weeks. All the vascular lesions healed after 15 days without any residual scarring. The end results for the use of the 980 nm diode laser in oral and facial surgery appears to be justified on the grounds of efficacy and safety of the device, and good degree of acceptance by the patients, without compromising their health and function.

  8. Understanding the exposure-time effect on speckle contrast measurements for laser displays

    Science.gov (United States)

    Suzuki, Koji; Kubota, Shigeo

    2018-02-01

    To evaluate the influence of exposure time on speckle noise for laser displays, speckle contrast measurement method was developed observable at a human eye response time using a high-sensitivity camera which has a signal multiplying function. The nonlinearity of camera light sensitivity was calibrated to measure accurate speckle contrasts, and the measuring lower limit noise of speckle contrast was improved by applying spatial-frequency low pass filter to the captured images. Three commercially available laser displays were measured over a wide range of exposure times from tens of milliseconds to several seconds without adjusting the brightness of laser displays. The speckle contrast of raster-scanned mobile projector without any speckle-reduction device was nearly constant over various exposure times. On the contrary to this, in full-frame projection type laser displays equipped with a temporally-averaging speckle-reduction device, some of their speckle contrasts close to the lower limits noise were slightly increased at the shorter exposure time due to the noise. As a result, the exposure-time effect of speckle contrast could not be observed in our measurements, although it is more reasonable to think that the speckle contrasts of laser displays, which are equipped with the temporally-averaging speckle-reduction device, are dependent on the exposure time. This discrepancy may be attributed to the underestimation of temporal averaging factor. We expected that this method is useful for evaluating various laser displays and clarify the relationship between the speckle noise and the exposure time for a further verification of speckle reduction.

  9. Fabrication of biosynthetic vascular prostheses by 193-nm excimer laser radiation

    Science.gov (United States)

    Husinsky, Wolfgang; Csek, Ch.; Bartel, A.; Grabenwoeger, M.; Fitzal, F.; Wolner, Ernst

    1998-05-01

    This study was undertaken to investigate the feasibility of transmural capillary ingrowth into the inner surface of biosynthetic vascular prostheses (OmniflowTM) through perforations created by an excimer-laser, thus inducing an endothelial cell coverage. The biosynthetic vascular prostheses (10 cm length, 6 mm (phi) ) were perforated with an excimer laser ((phi) of the holes 50 - 100 micrometer, distance 4 mm) and implanted into the carotid arteries of 8 sheep. The laser tissue interaction process of 193 nm radiation ensures minimal thermal damage to the prostheses. They were compared to untreated OmniflowTM prostheses implanted at the contralateral side. Three months after implantation the prostheses were explanted and evaluated by gross morphology, histological examination and scanning electron microscopy. Scanning electron microscopy showed endothelial cells in the midgraft portion of all perforated prostheses, whereas collagen fibers, fibrin meshwork and activated platelets formed the inner layer in 6 out of 8 untreated OmniflowTM prostheses. It can be concluded, that spontaneous endothelialization of biosynthetic vascular prostheses can be achieved by transmural capillary ingrowth through perforations in the wall of the prostheses in an experimental sheep model.

  10. Laser-assisted decontamination—A wavelength dependent study

    Science.gov (United States)

    Nilaya, J. Padma; Raote, Pallavi; Kumar, Aniruddha; Biswas, Dhruba J.

    2008-09-01

    We present here the experimental results on cleaning of radioactive dielectric particulates, loosely deposited on stainless steel, by coherent light of 1064 nm wavelength and its three harmonics occurring at 532 nm, 355 nm and 266 nm, derived from an Nd-YAG laser. For the initial few exposures, the decontamination factor has been found to be highest when exposed to 1064 nm radiation. With increasing number of exposures, however, the radiation with reducing wavelength assumes a more important role as a cleaning agent. The observation of almost no cleaning with 1064 nm and much reduced cleaning with its harmonics when the contamination is deposited on a transparent substrate confirms the dominant role played by metal substrate towards expelling the loose particulates from its surface.

  11. Tunable and stable single-longitudinal-mode dual-wavelength erbium fiber laser with 1.3 nm mode spacing output

    International Nuclear Information System (INIS)

    Yeh, C H; Shih, F Y; Wang, C H; Chow, C W; Chi, S

    2008-01-01

    In this investigation, we propose and investigate a stable and tunable dual-wavelength erbium-doped fiber (EDF) ring laser with self-injected Fabry-Perot laser diode (FP-LD) scheme. By using an FP-LD incorporated with a tunable bandpass filter (TBF) within the gain cavity, the fiber laser can lase at two single-longitudinal-mode (SLM) wavelengths simultaneously due to the self-injected operation. The proposed dual-wavelength laser has a good performance of the output power and optical side-mode suppression ratio (SMSR). The laser also shows a wide tuning range from 1523.08 to 1562.26 nm. Besides, the output stabilities of the fiber laser are also discussed

  12. On-chip nanostructuring and impedance trimming of transparent and flexible ITO electrodes by laser induced coherent sub-20 nm cuts

    Energy Technology Data Exchange (ETDEWEB)

    Afshar, Maziar, E-mail: m.afshar@lmm.uni-saarland.de [Lab for Micromechanics, Microfluidics, and Microactuators, Saarland University, Saarbrücken D-66123 (Germany); Leber, Moritz [Lab for Micromechanics, Microfluidics, and Microactuators, Saarland University, Saarbrücken D-66123 (Germany); Poppendieck, Wigand [Department of Medical Engineering & Neuroprosthetics, Fraunhofer Institute for Biomedical Engineering, St. Ingbert D-66386 (Germany); König, Karsten [Lab for Biophotonics and Laser Technology, Saarland University, Saarbrücken D-66123 (Germany); Seidel, Helmut; Feili, Dara [Lab for Micromechanics, Microfluidics, and Microactuators, Saarland University, Saarbrücken D-66123 (Germany)

    2016-01-01

    Graphical abstract: - Highlights: • A novel method to make sub-20 nm nanopatterning in ITO thin films by laser writing. • A novel way to functionalize ITO bio-electrodes to yield near-field polarizing feature. • A basic characterization of ITO electrodes was performed by impedance spectroscopy. • Presentation of simulations and possible theoretical approaches to explain the results. - Abstract: In this work, the effect of laser-induced nanostructuring of transparent indium tin oxide (ITO) electrodes on flexible glass is investigated. Multi-electrode arrays (MEA) for electrical and optical characterization of biological cells were fabricated using standard MEMS technologies. Optimal sputter parameters concerning oxygen flow, sputter power and ambient pressure for ITO layers with both good optical and electrical properties were determined. Afterwards, coherent sub-20 nm wide and 150 nm deep nanocuts of many micrometers in length were generated within the ITO electrodes by a sub-15 femtosecond (fs) pulsed laser. The influence of laser processing on the electrical and optical properties of electrodes was investigated. The electrochemical impedance of the manufactured electrodes was measured before and after laser modification using electrochemical impedance spectroscopy. A small reduction in electrode impedance was observed. These nanostructured electrodes show also polarizing effects by the visible spectrum.

  13. Nanosecond-pulsed Q-switched Nd:YAG laser at 1064 nm with a gold nanotriangle saturable absorber

    Science.gov (United States)

    Chen, Xiaohan; Li, Ping; Dun, Yangyang; Song, Teng; Ma, Baomin

    2018-06-01

    Gold nanotriangles (GNTs) were successfully employed as a saturable absorber (SA) to achieve passively Q-switched lasers for the first time. The performance of the Q-switched Nd:YAG laser at 1064 nm has been systematically investigated. The corresponding shortest pulsewidth, the threshold pump power and the maximum Q-switched average output power were 275.5 ns, 1.37 W, and 171 mW, respectively. To our knowledge, this is the shortest pulsewidth and the lowest threshold in a passively Q-switched laser at approximately 1.1 µm based on a gold nanoparticle SA (GNPs-SA). Our experimental results proved that the GNTs-SA can be used as a promising saturable absorber for nanosecond-pulsed lasers.

  14. A comparison of the antibacterial activity of the two methods of photodynamic therapy (using diode laser 810 nm and LED lamp 630 nm) against Enterococcus faecalis in extracted human anterior teeth.

    Science.gov (United States)

    Asnaashari, Mohammad; Mojahedi, Seyed Masoud; Asadi, Zahra; Azari-Marhabi, Saranaz; Maleki, Alireza

    2016-03-01

    Failure of endodontic treatment is usually due to an inadequate disinfection of the root canal system. Enterococcus faecalis has been widely used as a valuable microbiological marker for in-vitro studies because of its ability to colonize in a biofilm like style in root canals, invading dentinal tubules and resistance to some endodontic treatments. The aim of this study was to investigate the antibacterial effects of two methods of photodynamic therapy using a light emitting diode lamp (LED lamp, 630 nm) and a diode laser (810 nm) on E. faecalis biofilms in anterior extracted human teeth. Fifty six single-rooted extracted teeth were used in this study. After routine root canal cleansing, shaping and sterilization, the teeth were incubated with E. faecalis for a period of two weeks. Teeth were then divided into two experimental groups (nu=23) and two control groups (nu=5). Teeth in one experimental group were exposed to a diode laser (810 nm), and in the other group samples were exposed to a LED lamp (630 nm). Intracanal bacterial sampling was done, and bacterial survival rate was then evaluated for each group. The Colony Forming Unit (CFU) in LED group (log10 CFUs=4.88±0.82) was significantly lower than the laser group (log CFUs=5.49±0.71) (p value=0.021). CFUs in positive control group (Log10 CFUs=10.96±0.44) were significantly higher than the treatment group (p˂0.001). No bacterial colony was found in negative control group. The results of this research show that photodynamic therapy could be an effective supplement in root canal disinfection. PDT using LED lamp was more effective than diode laser 810 nm in reducing CFUs of E. faecalis in human teeth. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Split-face comparison of long-pulse-duration neodymium-doped yttrium aluminum garnet (Nd:YAG) 1,064-nm laser alone and combination long-pulse and Q-switched Nd:YAG 1,064-nm laser with carbon photoenhancer lotion for the treatment of enlarged pores in Asian women.

    Science.gov (United States)

    Wattanakrai, Penpun; Rojhirunsakool, Salinee; Pootongkam, Suwimon

    2010-11-01

    Long-pulse and Q-switched neodymium-doped yttrium aluminum garnet (Nd:YAG) 1,064-nm laser used for facial rejuvenation can improve pore size. Topical carbon has been used to enhance efficacy. To compare the efficacy and safety of a 1,064-nm long-pulse Nd:YAG laser alone with that of a combination Q-switched Nd:YAG laser with topical carbon lotion followed by long-pulse Nd:YAG to improve enlarged pores. Twenty Thai women randomly received five treatments with a long-pulse Nd:YAG laser on one facial half (LP side) and long-pulse Nd:YAG after carbon-assisted Q-switched Nd:YAG laser on the contralateral side (carbon QS+LP side) at 2-week intervals. Participants were evaluated using digital photography, complexion analysis, and a chromometer. There was significant decrease in pore counts of 35.5% and 33% from baseline on the carbon QS+LP and LP sides, respectively. Physician-evaluated pore size improvement was 67% on the carbon QS+LP sides and 60% on the LP sides. Chromometer measurement showed an increase in skin lightness index. There was no significant difference between the two treatments, although there were more adverse effects on the carbon QS+LP side. Long-pulse Nd:YAG 1,064-nm laser improves the appearance of facial pores and skin color. Adding carbon-assisted Q-switched Nd:YAG did not enhance the results but produced more side effects. © 2010 by the American Society for Dermatologic Surgery, Inc.

  16. Two-photon excitation laser scanning microscopy of porcine nasal septal cartilage following Nd:YAG laser-mediated stress relaxation

    Science.gov (United States)

    Kim, Charlton C.; Wallace, Vincent P.; Rasouli, Alexandre; Coleno, Mariah L.; Dao, Xavier; Tromberg, Bruce J.; Wong, Brian J.

    2000-05-01

    Laser irradiation of hyaline cartilage result in stable shape changes due to temperature dependent stress relaxation. In this study, we determined the structural changes in chondrocytes within porcine nasal septal cartilage tissue over a 4-day period using a two-photon laser scanning microscope (TPM) following Nd:YAG laser irradiation (lambda equals 1.32 micrometer) using parameters that result in mechanical stress relaxation (6.0 W, 5.4 mm spot diameter). TPM excitation (780 nm) result in induction of fluorescence from endogenous agents such as NADH, NADPH, and flavoproteins in the 400 - 500 nm spectral region. During laser irradiation diffuse reflectance (from a probe HeNe laser, (lambda) equals 632.8 nm), surface temperature, and stress relaxation were measured dynamically. Each specimen received one, two, or three sequential laser exposures (average irradiation times of 5, 6, and 8 seconds). The cartilage reached a peak surface temperature of about 70 degrees Celsius during irradiation. Cartilage denatured in 50% EtOH (20 minutes) was used as a positive control. TPM was performed using a mode-locked 780 nm Titanium:Sapphire (Ti:Al203) beam with a, 63X, 1.2 N.A. water immersion objective (working distance of 200 mm) to detect the fluorescence emission from the chondrocytes. Images of chondrocytes were obtained at depths up to 150 microns (lateral resolution equals 35 micrometer X 35 micrometer). Images were obtained immediately following laser exposure, and also after 4 days in culture. In both cases, the irradiated and non-irradiated specimens do not show any discernible difference in general shape or auto fluorescence. In contrast, positive controls (immersed in 50% ethanol), show markedly increased fluorescence relative to both the native and irradiated specimens, in the cytoplasmic region.

  17. Corneal tissue welding with infrared laser irradiation after clear corneal incision.

    Science.gov (United States)

    Rasier, Rfat; Ozeren, Mediha; Artunay, Ozgür; Bahçecioğlu, Halil; Seçkin, Ismail; Kalaycoğlu, Hamit; Kurt, Adnan; Sennaroğlu, Alphan; Gülsoy, Murat

    2010-09-01

    The aim of this study was to investigate the potential of infrared lasers for corneal welding to seal corneal cuts done in an experimental animal model. Full-thickness corneal cuts on freshly enucleated bovine eyes were irradiated with infrared (809-nm diode, 980-nm diode, 1070-nm YLF, and 1980-nm Tm:YAP) lasers to get immediate laser welding. An 809-nm laser was used with the topical application of indocyanine green to enhance the photothermal interaction at the weld site. In total, 60 bovine eyes were used in this study; 40 eyes were used in the first part of the study for the determination of optimal welding parameters (15 eyes were excluded because of macroscopic carbonization, opacification, or corneal shrinkage; 2 eyes were used for control), and 20 eyes were used for further investigation of more promising lasers (YLF and Tm:YAP). Laser wavelength, irradiating power, exposure time, and spot size were the dose parameters, and optimal dose for immediate closure with minimal thermal damage was estimated through histological examination of welded samples. In the first part of the study, results showed that none of the applications was satisfactory. Full-thickness success rates were 28% (2 of 7) for 809-nm and for 980-nm diode lasers and 67% (2 of 3) for 1070-nm YLF and (4 of 6) for 1980-nm Tm:YAP lasers. In the second part of the study, YLF and Tm:YAP lasers were investigated with bigger sample size. Results were not conclusive but promising again. Five corneal incisions were full-thickness welded out of 10 corneas with 1070-nm laser, and 4 corneal incisions were partially welded out of 10 corneas with 1980-nm laser in the second part of the study. Results showed that noteworthy corneal welding could be obtained with 1070-nm YLF laser and 1980-nm Tm:YAP laser wavelengths. Furthermore, in vitro and in vivo studies will shed light on the potential usage of corneal laser welding technique.

  18. Determination of pulse energy dependence for skin denaturation from 585nm fibre laser

    Science.gov (United States)

    Mujica-Ascencio, S.; Velazquez-Gonzalez, J. S.; Mujica-Ascencio, C.; Alvarez-Chavez, J. A.

    2014-05-01

    In this paper, simulation and mathematical analysis for the determination of pulse energy from a Q-switched Yb3+-doped fibre laser is required in Port Wine Stain (PWS) treatment. The pulse energy depends on average power, gain, volume, repetition rate and pulse duration. In some treatments such as Selective Photothermolysis (SP), the peak power at the end of the optical fibre and pulse duration can be obtained and modified via a cavity design. For that purpose, a 585nm optical fibre laser full design which considers all of the above besides the average losses through the optical devices proposed for the design and the Ytterbium optical fibre overall gain will be presented.

  19. Effect of excimer laser (Arf, 193 nm) on aqueous humor during photorefractive keratectomy biophysical and biochemical study

    International Nuclear Information System (INIS)

    Mahmoud, S.S.; Mahmoud, A.A.

    2004-01-01

    Ultraviolet light (193 nm) produced by an excimer laser has been used to produce precise tissue ablation with minimal thermal damage to adjacent tissue. The present study was designed to investigate the effect of excimer laser during photo refractive keratectomy (PRK) on aqueous humor constituents and also the effect of antioxidant enzyme superoxide dismutase (SOD)- applied topically- on these changes if exist. Five groups of schenchilla rabbits were involved in this study, where four groups underwent corneal stromal ablation using argon fluoride excimer laser (Ar F, 193 nm). Two of these four groups were treated with superoxide dismutase intra operatively. The fifth group was used as control one. The obtained results revealed depletion of aqueous humor ascorbate and glutathione contents. Aqueous humor refractive index, cholesterol, phospholipids, malondialdehyde (MDA) and total protein were measured. In conclusion, the excimer laser can induce changes in aqueous humor constituents during PRK. These changes lasted at least for 24 hours and as the time increased to 4 weeks, these changes became limited. The use of exogenous SOD seems to exert beneficial effect on aqueous humor refractive index and total protein

  20. Sub-40 fs, 1060-nm Yb-fiber laser enhances penetration depth in nonlinear optical microscopy of human skin

    Science.gov (United States)

    Balu, Mihaela; Saytashev, Ilyas; Hou, Jue; Dantus, Marcos; Tromberg, Bruce J.

    2015-12-01

    Advancing the practical utility of nonlinear optical microscopy requires continued improvement in imaging depth and contrast. We evaluated second-harmonic generation (SHG) and third-harmonic generation images from ex vivo human skin and showed that a sub-40 fs, 1060-nm Yb-fiber laser can enhance SHG penetration depth by up to 80% compared to a >100 fs, 800 nm Ti:sapphire source. These results demonstrate the potential of fiber-based laser systems to address a key performance limitation related to nonlinear optical microscopy (NLOM) technology while providing a low-barrier-to-access alternative to Ti:sapphire sources that could help accelerate the movement of NLOM into clinical practice.

  1. 926 nm laser operation in Nd:GdNbO4 crystal based on 4F3/2 → 4I9/2 transition

    Science.gov (United States)

    Yan, Renpeng; Li, Xudong; Yao, Wenming; Shen, Yingjie; Zhou, Zhongxiang; Peng, Fang; Zhang, Qingli; Dou, Renqing; Gao, Jing

    2018-05-01

    926 nm laser operation in a Nd:GdNbO4 crystal based on quasi-three-level 4F3/2 → 4I9/2 transition is reported, for the first time to our best knowledge. An average output power of 393 mW at 926 nm under 879 nm LD pumping is obtained with a slope efficiency of 33.3% and an optical-to-optical efficiency of 26.0%. The slope efficiency with respect to absorbed pump power is estimated to be 47.7%. Comparison between output characters of 926 nm laser under direct and indirect pumping is conducted. The average output power at 926 nm under 808 nm LD pumping reaches 305 mW with an optical-to-optical efficiency of 16.1%.

  2. Analysis of opto-thermal interaction of porcine stomach tissue with 808-nm laser for endoscopic submucosal dissection

    Directory of Open Access Journals (Sweden)

    Seongjun Kim

    2015-11-01

    Full Text Available In endoscopic submucosal dissection (ESD, the narrow gastrointestinal space can cause difficulty in surgical interventions. Tissue ablation apparatuses with high-power CO2 lasers or Nd:YAG lasers have been developed to facilitate endoscopic surgical procedures. We studied the interaction of 808-nm laser light with a porcine stomach tissue, with the aim of developing a therapeutic medical device that can remove lesions at the gastrointestinal wall by irradiating a near-infrared laser light incorporated in an endoscopic system. The perforation depths at the porcine fillet and the stomach tissues linearly increased in the range of 2–8 mm in proportion to the laser energy density of 63.7–382 kJ/cm2. Despite the distinct structural and compositional difference, the variation of the perforation depth between the stomach and the fillet was not found at 808-nm wavelength in our measurement. We further studied the laser–tissue interaction by changing the concentration of the methyl blue solution used conventionally as a submucosal fluidic cushion (SFC in ESD procedures. The temperature of the mucosal layer increased more rapidly at higher concentration of the methyl blue solution, because of enhanced light absorption at the SFC layer. The insertion of the SFC would protect the muscle layer from thermal damage. We confirmed that more effective laser treatment should be enabled by tuning the opto-thermal properties of the SFC. This study can contribute to the optimization of the driving parameters for laser incision techniques as an alternative to conventional surgical interventions.

  3. Multiphoton ionization and fragmentation study of acetone using 308 nm laser radiation

    Science.gov (United States)

    Liu Houxiang, Li Shutao, Han Jingcheng, Zhu Rong, Guan Yifu, Wu Cunkai

    1988-10-01

    Multiphoton ionization and fragmentation (MPI-F) of acetone molecules using 308 nm laser radiation was studied by using a molecular beam and quadrupole mass spectrometer. The ion peaks of acetone molecule appear at m/e=15 and 43, corresponding to the two fragments CH3+ and CH3CO+. It is considered that these two ions are, respectively, formed by direct (2+1) and 2-photon ionization of methyl and acetyl radicals, generated by photodissociation of acetone molecule.

  4. Highly efficient single-pass frequency doubling of a continuous-wave distributed feedback laser diode using a PPLN waveguide crystal at 488 nm.

    Science.gov (United States)

    Jechow, Andreas; Schedel, Marco; Stry, Sandra; Sacher, Joachim; Menzel, Ralf

    2007-10-15

    A continuous-wave distributed feedback diode laser emitting at 976 nm was frequency doubled by the use of a periodically poled lithium niobate waveguide crystal with a channel size of 3 microm x 5 microm and an interaction length of 10 mm. A laser to waveguide coupling efficiency of 75% could be achieved resulting in 304 mW of incident infrared light inside the waveguide. Blue laser light emission of 159 mW at 488 nm has been generated, which equals to a conversion efficiency of 52%. The resulting wall plug efficiency was 7.4%.

  5. A quasi-three-level dual-wavelength thin-disk laser at 1024 and 1030 nm based on a diode-pumped Yb:YAG crystal

    International Nuclear Information System (INIS)

    Sun, G C; Li, Y D; Zhao, M; Chen, X Y; Wang, J B; Chen, G B

    2013-01-01

    A diode-end-pumped Yb:YAG dual-wavelength continuous-wave (cw) laser that generates simultaneous laser action at wavelengths of 1024 and 1030 nm is demonstrated for the first time. A total output power of 897 mW for the dual-wavelength was achieved at an incident pump power of 17.8 W. Furthermore, intracavity sum-frequency mixing at 1024 and 1030 nm was then realized in an LBO crystal to reach the green range. We obtained a total cw output power of 85 mW at 513.5 nm. (paper)

  6. High Performance self-injection locked 524 nm green laser diode for high bitrate visible light communications

    KAUST Repository

    Shamim, Md. Hosne Mobarok; Shemis, Mohamed; Shen, Chao; Oubei, Hassan M.; Ng, Tien Khee; Ooi, Boon S.; Khan, Mohammed Zahed Mustafa

    2018-01-01

    First demonstration of self-injection locking on 524 nm visible laser diode is presented. Enhancement by ~440 MHz (~30%) in modulation bandwidth, ~7 times reduction in lasing linewidth, and ~10 dB improvement in SMSR is achieved.

  7. High Performance self-injection locked 524 nm green laser diode for high bitrate visible light communications

    KAUST Repository

    Shamim, Md. Hosne Mobarok

    2018-03-05

    First demonstration of self-injection locking on 524 nm visible laser diode is presented. Enhancement by ~440 MHz (~30%) in modulation bandwidth, ~7 times reduction in lasing linewidth, and ~10 dB improvement in SMSR is achieved.

  8. Particle emission from polymer-doped water ice matrices induced by non-linear absorption of laser light at 1064 nm

    DEFF Research Database (Denmark)

    Purice, A.; Schou, Jørgen; Dinescu, M.

    2006-01-01

    Emission of PEG (polyethylene glycol) molecules and ions from an ice target induced by laser irradiation in the infrared (IR) regime at 1064 nm was studied. Matrices of 1 wt% PEG flash-frozen solutions were used for polymer deposition with MAPLE (matrix assisted pulsed laser evaporation). Even...

  9. Evaluating the safety and efficacy of the 1,440-nm laser in the treatment of photodamage in Asian skin.

    Science.gov (United States)

    Marmon, Shoshana; Shek, Samantha Y N; Yeung, C K; Chan, Nicola P Y; Chan, Johnny Cy; Chan, Henry H L

    2014-07-01

    As the demand for diminished procedure-associated downtime continues to increase, nonablative fractional laser resurfacing is becoming a more popular intervention in the progression of photoaging. Patients with pigmented skin and a mild degree of photodamage may be particularly suited for a less intensive laser treatment. In this study, we have evaluated the safety and efficacy of a low energy, low density 1,440-nm fractional laser in the treatment of multiple signs of photoaging including dyspigmentation, wrinkling, tissue laxity, enlarged pores, and skin roughness in Asians. Ten Chinese subjects with Fitzpatrick skin types III-V and visible signs of photodamage participated in this study. Patients received four treatments at 2-week intervals with a 1,440-nm diode-based fractional laser. Photographs were taken at baseline, 2 weeks after each of the first three treatments and 4 weeks after the final treatment. Images were evaluated independently by two physicians. Clinical improvement and adverse events were analyzed. Discomfort, heat sensation and overall patient satisfaction associated with the procedure were also quantified. In this prospective single-arm study, signs of photoaging were examined after treatment with the 1,440-nm laser. Here we show that a series of four treatments with this device produced a mild improvement in skin texture, pigmentation, and wrinkling. Changes in pore size and skin laxity failed to reach statistical significance. Immediate after-effects of the procedure included erythema and edema which were transient and left no permanent sequela. A significant proportion of patients reported some degree of discomfort during the procedure despite use of a topical anesthetic. One patient developed a discrete, localized area of post-inflammatory hyperpigmentation which completely resolved by the final follow up visit. The low energy, low density nonablative 1,440-nm fractional laser produces a mild improvement in select signs of photodamage

  10. Laser-damage thresholds of thin-film optical coatings at 248 nm

    International Nuclear Information System (INIS)

    Milam, D.; Rainer, F.; Lowdermilk, W.H.

    1981-01-01

    We have measured the laser-induced damage thresholds for 248 nm wavelength light of over 100 optical coatings from commercial vendors and research institutions. All samples were irradiated once per damage site with temporally multi-lobed, 20-ns pulses generated by a KrF laser. The survey included high, partial, and dichroic reflectors, anti-reflective coatings, and single layer films. The samples were supplied by ten vendors. The majority of samples tested were high reflectors and antireflective coatings. The highest damage thresholds were 8.5 to 9.4 J/cm 2 , respectively. Although these represent extremes of what has been tested so far, several vendors have produced coatings of both types with thresholds which consistently exceed 6 J/cm 2 . Repeated irradiations of some sites were made on a few samples. These yielded no degradation in threshold, but in fact some improvement in damage resistance. These same samples also exhibited no change in threshold after being retested seven months later

  11. Interaction of pulse laser radiation of 532 nm with model coloration layers for medieval stone artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Colson, J. [University of Vienna, Department of Physical Chemistry, A-1090 Vienna (Austria); Nimmrichter, J. [Austrian Federal Office for the Care of Monuments, Department for Conservation and Restoration, Arsenal, Objekt 15, Tor 4, A-1030 Vienna (Austria); Kautek, W., E-mail: wolfgang.kautek@univie.ac.at [University of Vienna, Department of Physical Chemistry, A-1090 Vienna (Austria)

    2014-05-01

    Multilayer polychrome coatings on medieval and Renaissance stone artefacts represent substantial challenges in laser cleaning. Therefore, polychromic models with classical pigments, minium (Pb{sub 2}{sup 2+}Pb{sup 4+}O{sub 4}), zinc white (ZnO), and lead white ((PbCO{sub 3}){sub 2}·Pb(OH){sub 2}) in an acrylic binder, were irradiated with a Q-switched Nd:YAG laser emitting at 532 nm. The studied medieval pigments exhibit strongly varying incubation behaviours directly correlated to their band gap energies. Higher band gaps beyond the laser photon energy of 2.3 eV require more incubative generation of defects for resonant transitions. A matching of the modification thresholds after more than four laser pulses was observed. Laser cleaning with multiple pulsing should not exceed ca. 0.05 J/cm{sup 2} when these pigments coexist in close spatial proximity.

  12. Bragg grating photo-inscription in doped microstructured polymer optical fiber by 400 nm femtosecond laser pulses.

    OpenAIRE

    Hu, X.; Woyessa, Getinet; Kinet, D.; Janting, Jakob; Nielsen, Kristian; Bang, Ole; Mégret, P.; Caucheteur, C.

    2016-01-01

    In this paper, we report the manufacturing of high-quality endlessly single-mode doped microstructured poly(methyl methacrylate) (PMMA) optical fibers. Bragg gratings are photo-inscribed in such fibers by means of 400 nm femtosecond laser pulses through a 1060-nm-period uniform phase mask. Preliminary results show a rapid growing process of the reflection band. To preserve a good spectral shape, the photo-inscription process was limited to ~20 seconds, yielding an FBG reflectivity close to 40 %.

  13. High-pulse energy supercontinuum laser for high-resolution spectroscopic photoacoustic imaging of lipids in the 1650-1850 nm region

    DEFF Research Database (Denmark)

    Dasa, Manoj Kumar; Markos, Christos; Maria, Michael

    2018-01-01

    We propose a cost-effective high-pulse energy supercontinuum (SC) source based on a telecom range diode laser-based amplifier and a few meters of standard single-mode optical fiber, with a pulse energy density as high as ∼25 nJ/nm in the 1650-1850 nm regime (factor >3 times higher than any SC...... discrimination of two different lipids (cholesterol and lipid in adipose tissue) and the photoacoustic cross-sectional scan of lipid-rich adipose tissue at three different locations. The proposed high-pulse energy SC laser paves a new direction towards compact, broadband and cost-effective source...

  14. Evaluation of thermal damage in dental implants after irradiation with 980nm diode laser. An in vitro study

    Directory of Open Access Journals (Sweden)

    Carlo Cafiero

    2016-12-01

    Full Text Available Purpose: The aim of this study was to analyze the thermal damage in dental implants after irradiations with a 980nm diode laser, normally used for the decontamination. Material and Methods: Five Titanium Plasma Sprayed dental implants were irradiated with a 980nm diode laser at different parameters. Temperature increase on implant surface was evaluated by a Mid-Wavelength Infrared thermal-camera (Merlin®, FLIR, USA. Temperature increase (ΔT was compared to environmental temperature (27°C and recorded in three points: “A” (laser spot, “B” (3mm apically to the laser spot and “C” (2mm horizontally to the laser spot. Finally, a morphological evaluation at optical stereomicroscopy was performed. Results: When 0.6W power was applied, a moderate increase of temperature in point A (5.5°C-15.0°C, a slight increase in point B (0.1°C-6.2°C and point C (0.1°C-5.7°C, were registered after 30” of irradiation. In the samples treated at 6W, in “point A” an impressive ΔT increase was immediately recorded (over 70°C. In “point B” was recorded a slight ΔT after 2 sec. irradiation (range 2.3°C-6.0°C, a moderate ΔT after 4 sec. irradiation (16.4°C and a consistent ΔT after 8-10 sec. irradiation (range 36.6°C-46.2°C. In “point C” ΔT values were very similar to those collected in “point B”. Optical stereomicroscopy examination at a magnification of 32x did not show any surface alteration or damage after whichever laser irradiation independently from irradiation time and power output . Conclusions: 980nm diode laser, used at controlled parameters, can be used in the decontamination of dental implants, without causing any thermal damage or increase.

  15. Treatment of flat and elevated pigmented disorders with a 755-nm alexandrite picosecond laser: clinical and histological evaluation.

    Science.gov (United States)

    Alegre-Sanchez, Adrian; Jiménez-Gómez, Natalia; Moreno-Arrones, Óscar M; Fonda-Pascual, Pablo; Pérez-García, Bibiana; Jaén-Olasolo, Pedro; Boixeda, Pablo

    2018-02-09

    The novel picosecond lasers, initially developed for faster tattoo removal, have also shown great efficacy in endogenous pigmentary disorders. To describe the efficacy and safety profile of an alexandrite (755-nm) picosecond laser in a wide range of pigmented flat and elevated cutaneous lesions. A retrospective study was performed in which we collected all the clinical images of patients treated with the 755-nm alexandrite picosecond laser for 12 months (November 2016-November 2017). Clinical features were obtained from their medical charts. Patients treated for tattoo removal were excluded. All the images were analyzed by three blind physicians attending to a visual analogue scale (VAS) from 0 to 5 (0, no change; 1, 1-24% clearance; 2, 25-49% clearance; 3, 50-74% clearance; 4, 75-99% clearance; 5, complete clearance). Patient satisfaction was obtained from a subjective survey including four items: very satisfied, satisfied, non-satisfied, and totally dissatisfied. Thirty-seven patients were included (12 males; 25 females). The mean age of the study was 42.35 years. Twenty-five patients (68%) were treated for different pigmented flat disorders such as solar and mucosal lentigines (5), stasis dermatitis (4), or nevus of Ota (4), among other diagnoses. Twelve patients (32%) were treated for epidermal elevated lesions such as warts (5), epidermal nevi (2), and seborrheic keratosis (3), among other elevated lesions. Mean number of laser treatment was 3.02 sessions while mean follow-up after last laser treatment was 4.02 months. Mean VAS score of the three observers was 3.44 (61% of clearance) for pigmentary flat disorders and 3.60 (67%) for elevated lesions. Adverse effects reported were mild blistering in the first 2-5 days following laser treatment in some of the patients. Overall satisfaction among the patients included was high. The novel 755-nm picosecond alexandrite laser is effective not only for the resolution of pigmented flat lesions of different nature

  16. 1.9 W continuous-wave single transverse mode emission from 1060 nm edge-emitting lasers with vertically extended lasing area

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M. J., E-mail: jarez.miah@tu-berlin.de; Posilovic, K.; Kalosha, V. P.; Rosales, R.; Bimberg, D. [Institut für Festkörperphysik, Technische Universität Berlin, Hardenbergstr. 36, 10623 Berlin (Germany); Kettler, T. [Institut für Festkörperphysik, Technische Universität Berlin, Hardenbergstr. 36, 10623 Berlin (Germany); PBC Lasers GmbH, Hardenbergstr. 36, 10623 Berlin (Germany); Skoczowsky, D. [PBC Lasers GmbH, Hardenbergstr. 36, 10623 Berlin (Germany); Pohl, J.; Weyers, M. [Ferdinand-Braun-Institut für Höchstfrequenztechnik, Gustav-Kirchhoff-Str. 4, 12489 Berlin (Germany)

    2014-10-13

    High-brightness edge-emitting semiconductor lasers having a vertically extended waveguide structure emitting in the 1060 nm range are investigated. Ridge waveguide (RW) lasers with 9 μm stripe width and 2.64 mm cavity length yield highest to date single transverse mode output power for RW lasers in the 1060 nm range. The lasers provide 1.9 W single transverse mode optical power under continuous-wave (cw) operation with narrow beam divergences of 9° in lateral and 14° (full width at half maximum) in vertical direction. The beam quality factor M{sup 2} is less than 1.9 up to 1.9 W optical power. A maximum brightness of 72 MWcm{sup −2}sr{sup −1} is obtained. 100 μm wide and 3 mm long unpassivated broad area lasers provide more than 9 W optical power in cw operation.

  17. Evaluation of Energy Dose and Output Power Optimum of Diode’s Laser of 450 nm and 650 nm in Photoantimicrobial Mechanisms Against Inhibition of C. Albicans Biofilm Cells

    Science.gov (United States)

    Dewi-Astuty, S.; Suhariningsih; Dyah-Astuti, S.; Baktir, A.

    2018-03-01

    Photoantimicrobial as a pathogenic microbial inhibitory therapy system such as C. albicans in biofilms forms has been studied in vitro. Mechanisms of inhibiting called inactivating used the absorb principles of a dye agents such as chlorophyll against the photon energy of diode laser which any number of ROS product depend on energy doses of a laser, time of irradiation, concentration and time of incubation the dyes agent. The inactivation profile of C. albicans biofilm cells was observed based on cell viability reduction after photoantimicrobial treatment with or without oxygenation by XTT assay test. Results show that the inhibiting significantly with the time incubation of the dye agents and the oxygen degree inside the sample. The inhibition for oxygenation biofilm’s group 10% lower than without oxygenation biofilm’s group at the maximum of reduction of cell viability occurred in the 3hour incubation group. Optimum of inactivation are 89.6% (without oxygenation) and 94.8% (with oxygenation) after irradiation with 450 nm laser (power output 128.73 at energy dose 86.09 J/cm2), While, by 650 nm laser (power output 164.53 mW at energy dose 92.52 J/cm2) irradiation treatment obtained optimum of inactivation are 89.5% (without oxygenation) and 92.3% (with oxygenation).

  18. Hypersensitisation using 266nm Laser Light

    DEFF Research Database (Denmark)

    Sørensen, Henrik Rokkjær; Canning, John; Kristensen, Martin

    UV-hypersensitisation using 266nm VW-light on hydrogenated Ge-doped fibre is reported. The optimum fluence to be between 5 to 10 kJ/cm2, coinciding with results obtained using 355nm light, indicating same end-process in both reactions.......UV-hypersensitisation using 266nm VW-light on hydrogenated Ge-doped fibre is reported. The optimum fluence to be between 5 to 10 kJ/cm2, coinciding with results obtained using 355nm light, indicating same end-process in both reactions....

  19. Intracavity doubling of CW Ti:sapphire laser to 392.5 nm using BiBO-crystal

    DEFF Research Database (Denmark)

    Mortensen, Jesper Liltorp; Thorhauge, Morten; Tidemand-Lichtenberg, Peter

    2005-01-01

    In this work we present results obtained for intra-cavity frequency-doubling of a 785 nm CW Ti:sapphire laser utilising BiBO as the non-linear crystal. Intracavity doubling offers several advantages compared to extra-cavity doubling, such as no need to couple to an external resonance cavity...

  20. An efficient continuous-wave 591 nm light source based on sum-frequency mixing of a diode pumped Nd:GdVO4–Nd:CNGG laser

    International Nuclear Information System (INIS)

    Zhao, Y D; Liu, J H

    2013-01-01

    We report a laser architecture to obtain continuous-wave (CW) yellow-orange light sources at the 591 nm wavelength. An 808 nm diode pumped a Nd:GdVO 4 crystal emitting at 1063 nm. A part of the pump power was then absorbed by the Nd:CNGG crystal. The remaining pump power was used to pump a Nd:CNGG crystal emitting at 1329 nm. Intracavity sum-frequency mixing at 1063 and 1329 nm was then realized in a LiB 3 O 5 (LBO) crystal to reach the yellow-orange radiation. We obtained a CW output power of 494 mW at 591 nm with a pump laser diode emitting 17.8 W at 808 nm. (paper)

  1. Investigation of Carbon Fiber Reinforced Plastics Machining Using 355 nm Picosecond Pulsed Laser

    Science.gov (United States)

    Hu, Jun; Zhu, Dezhi

    2018-06-01

    Carbon fiber reinforced plastics (CFRP) has been widely used in the aircraft industry and automobile industry owing to its superior properties. In this paper, a Nd:YVO4 picosecond pulsed system emitting at 355 nm has been used for CFRP machining experiments to determine optimum milling conditions. Milling parameters including laser power, milling speed and hatch distance were optimized by using box-behnken design of response surface methodology (RSM). Material removal rate was influenced by laser beam overlap ratio which affects mechanical denudation. The results in heat affected zones (HAZ) and milling quality were discussed through the machined surface observed with scanning electron microscope. A re-focusing technique based on the experiment with different focal planes was proposed and milling mechanism was also analyzed in details.

  2. New semiconductor laser technology for gas sensing applications in the 1650nm range

    Science.gov (United States)

    Morrison, Gordon B.; Sherman, Jes; Estrella, Steven; Moreira, Renan L.; Leisher, Paul O.; Mashanovitch, Milan L.; Stephen, Mark; Numata, Kenji; Wu, Stewart; Riris, Haris

    2017-08-01

    Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. CH4 also contributes to pollution in the lower atmosphere through chemical reactions leading to ozone production. Recent developments of LIDAR measurement technology for CH4 have been previously reported by Goddard Space Flight Center (GSFC). In this paper, we report on a novel, high-performance tunable semiconductor laser technology developed by Freedom Photonics for the 1650nm wavelength range operation, and for LIDAR detection of CH4. Devices described are monolithic, with simple control, and compatible with low-cost fabrication techniques. We present 3 different types of tunable lasers implemented for this application.

  3. Investigation of Carbon Fiber Reinforced Plastics Machining Using 355 nm Picosecond Pulsed Laser

    Science.gov (United States)

    Hu, Jun; Zhu, Dezhi

    2017-08-01

    Carbon fiber reinforced plastics (CFRP) has been widely used in the aircraft industry and automobile industry owing to its superior properties. In this paper, a Nd:YVO4 picosecond pulsed system emitting at 355 nm has been used for CFRP machining experiments to determine optimum milling conditions. Milling parameters including laser power, milling speed and hatch distance were optimized by using box-behnken design of response surface methodology (RSM). Material removal rate was influenced by laser beam overlap ratio which affects mechanical denudation. The results in heat affected zones (HAZ) and milling quality were discussed through the machined surface observed with scanning electron microscope. A re-focusing technique based on the experiment with different focal planes was proposed and milling mechanism was also analyzed in details.

  4. Study on the performance of eosin-doped poly(vinyl alcohol)/acrylamide photopolymer films for holographic recording using 488-nm wavelength

    Science.gov (United States)

    Rajesh, Chelakkal Sukumaran; Sreeroop, Sasidharan Savithrydevi; Pramitha, Vayalamkuzhi; Joseph, Rani; Sreekumar, Krishnapillai; Kartha, Cheranellore Sudha

    2011-12-01

    This article reports a study done on eosin-doped poly(vinyl alcohol)/acrylamide films for holographic recording using 488 nm Ar+ laser. Films were fabricated using gravity settling method at room temperature and were stored under normal laboratory conditions. Ar+ laser (488 nm) was used for fringe recording. Characterization was done by real time transmittance measurement, optical absorption studies, and diffraction efficiency measurements. Various holographic parameters such as exposure energy, recording power, spatial frequency, etc., were optimized so as to ensure maximum performance. More than 85% diffraction efficiency was obtained at an exposure energy of 50 mJ/cm2 in the optimized film. Efforts were taken to study the environmental stability of this self-developing polymeric material by looking at its shelf life and storage life. Compatibility for recording transmission hologram was also checked.

  5. Compact and high repetition rate Kerr-lens mode-locked 532 nm Nd:YVO4 laser

    International Nuclear Information System (INIS)

    Li, Zuohan; Peng, Jiying; Yuan, Ruixia; Yao, Jianquan; Zheng, Yi; Wang, Tongtong

    2015-01-01

    A compact and feasible CW Kerr-lens-induced mode-locked 532 nm Nd:YVO 4 laser system was experimentally demonstrated for the first time with theoretical analysis. Kerr-lens mode locking with intracavity second harmonic generation provides a promising method to generate a high-repetition-rate picosecond green laser. With an incident pump power of 6 W, the average output power of mode locking was 258 mW at a high repetition rate of 1.1 GHz. (paper)

  6. Microchannel fabrication on cyclic olefin polymer substrates via 1064 nm Nd:YAG laser ablation

    Energy Technology Data Exchange (ETDEWEB)

    McCann, Ronán [Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9 (Ireland); School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin 9 (Ireland); Irish Separation Science Cluster, National Centre for Sensor Research, Dublin City University, Dublin 9 (Ireland); National Centre for Plasma Science and Technology, Dublin City University, Dublin 9 (Ireland); Bagga, Komal; Groarke, Robert [Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9 (Ireland); School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin 9 (Ireland); Irish Separation Science Cluster, National Centre for Sensor Research, Dublin City University, Dublin 9 (Ireland); Stalcup, Apryll [Irish Separation Science Cluster, National Centre for Sensor Research, Dublin City University, Dublin 9 (Ireland); School of Chemical Sciences, Dublin City University, Dublin 9 (Ireland); Vázquez, Mercedes, E-mail: mercedes.vazquez@dcu.ie [Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9 (Ireland); Irish Separation Science Cluster, National Centre for Sensor Research, Dublin City University, Dublin 9 (Ireland); School of Chemical Sciences, Dublin City University, Dublin 9 (Ireland); Brabazon, Dermot [Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9 (Ireland); School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin 9 (Ireland); Irish Separation Science Cluster, National Centre for Sensor Research, Dublin City University, Dublin 9 (Ireland); National Centre for Plasma Science and Technology, Dublin City University, Dublin 9 (Ireland)

    2016-11-30

    Highlights: • Rapid single-step microchannel fabrication on optically transparent cyclic olefin polymer using IR Nd:YAG laser. • Ability to tailor channel depth between 12–47 μm demonstrated for single laser pass. • Use of multiple laser passes showed capability for finer depth control. • Potential applications in lab-on-chip and microfluidic devices. - Abstract: This paper presents a method for fabrication of microchannels on cyclic olefin polymer films that have application in the field of microfluidics and chemical sensing. Continuous microchannels were fabricated on 188-μm-thick cyclic olefin polymer substrates using a picosecond pulsed 1064 nm Nd:YAG laser. The effect of laser fluence on the microchannel morphology and dimensions was analysed via scanning electron microscopy and optical profilometry. Single laser passes were found to produce v-shaped microchannels with depths ranging from 12 μm to 47 μm and widths from 44 μm to 154 μm. The ablation rate during processing was lower than predicted theoretically. Multiple laser passes were applied to examine the ability for finer control over microchannel morphology with channel depths ranging from 22 μm to 77 μm and channel widths from 59 μm to 155 μm. For up to five repeat passes, acceptable reproducibility was found in the produced microchannel morphology. Infrared spectroscopy revealed oxidation and dehydrogenation of the polymer surface following laser ablation. These results were compared to other work conducted on cyclic olefin polymers.

  7. Microchannel fabrication on cyclic olefin polymer substrates via 1064 nm Nd:YAG laser ablation

    International Nuclear Information System (INIS)

    McCann, Ronán; Bagga, Komal; Groarke, Robert; Stalcup, Apryll; Vázquez, Mercedes; Brabazon, Dermot

    2016-01-01

    Highlights: • Rapid single-step microchannel fabrication on optically transparent cyclic olefin polymer using IR Nd:YAG laser. • Ability to tailor channel depth between 12–47 μm demonstrated for single laser pass. • Use of multiple laser passes showed capability for finer depth control. • Potential applications in lab-on-chip and microfluidic devices. - Abstract: This paper presents a method for fabrication of microchannels on cyclic olefin polymer films that have application in the field of microfluidics and chemical sensing. Continuous microchannels were fabricated on 188-μm-thick cyclic olefin polymer substrates using a picosecond pulsed 1064 nm Nd:YAG laser. The effect of laser fluence on the microchannel morphology and dimensions was analysed via scanning electron microscopy and optical profilometry. Single laser passes were found to produce v-shaped microchannels with depths ranging from 12 μm to 47 μm and widths from 44 μm to 154 μm. The ablation rate during processing was lower than predicted theoretically. Multiple laser passes were applied to examine the ability for finer control over microchannel morphology with channel depths ranging from 22 μm to 77 μm and channel widths from 59 μm to 155 μm. For up to five repeat passes, acceptable reproducibility was found in the produced microchannel morphology. Infrared spectroscopy revealed oxidation and dehydrogenation of the polymer surface following laser ablation. These results were compared to other work conducted on cyclic olefin polymers.

  8. Non-linear behaviour of power density and exposure time of argon laser on ocular tissues

    Energy Technology Data Exchange (ETDEWEB)

    El-Sayed, E M; Talaat, M S; Salem, E F [Physics Department, Faculty of Science, Ain Shams University, Cairo (Egypt)

    1997-12-31

    In ophthalmology, the thermal effect of argon laser is the most widely used category of laser- tissue interaction. The rise in tissue temperature has to exceed a threshold value for photo coagulation of retinal blood vessels. This value mainly depends on the laser. The most suitable argon laser power P and exposure time (t) which would be more effective for thermal and electrical behaviour of chicken eye was studied. This was achieved by measuring the variations in ocular temperature in electroretinogram (ERG) records under the effect of argon experiment, while power density (P) and exposure time (t) were varied in four different ways for each dose (pt). Results indicated that for the same laser dose, the temperature distribution of the eye, using low power density and high exposure time was higher than that high power density and low exposure time, indicating non-linearity of the laser dose. This finding was confirmed by ERG records which showed similar variations in b-wave latency, amplitude and duration, for the laser exposure conditions. This indicates variations in retinal function due to laser-dependent temperature variations. 5 figs., 3 tabs.

  9. Investigating the effects of laser beams (532 and 660 nm) in annihilation of pistachio mould fungus using spectrophotometry analysis

    Science.gov (United States)

    Saghafi, S.; Penjweini, R.; Becker, K.; Kratky, K. W.; Dodt, H.-U.

    2010-09-01

    When moulds are illuminated by visible electromagnetic-EM radiations, several effects on nucleus materials and nucleotides can be detected. These effects have a significant influence on mould generation or destruction. This paper presents the effects and implications of a red diode laser beam (660 nm), a second-harmonics of a Nd:YAG laser emitting green beam (532 nm), or the combination of both, on the eradication of Pistachio mould fungus. Incident doses (ID) of both beams are kept identical throughout the experiment. The absorption spectrums of irradiated mouldy samples and the bright-greenish-yellow-fluorescence (BGYF) of fungus occurring in mould texture due to electronic excitation are investigated. We found that a combination of a green and a red laser beam with an ID of 0.5 J/cm2 provides the optimal effects on Pistachio mould fungus eradication.

  10. High-power narrow-linewidth quasi-CW diode-pumped TEM00 1064 nm Nd:YAG ring laser.

    Science.gov (United States)

    Liu, Yuan; Wang, Bao-shan; Xie, Shi-yong; Bo, Yong; Wang, Peng-yuan; Zuo, Jun-wei; Xu, Yi-ting; Xu, Jia-lin; Peng, Qin-jun; Cui, Da-fu; Xu, Zu-yan

    2012-04-01

    We demonstrated a high average power, narrow-linewidth, quasi-CW diode-pumped Nd:YAG 1064 nm laser with near-diffraction-limited beam quality. A symmetrical three-mirror ring cavity with unidirectional operation elements and an etalon was employed to realize the narrow-linewidth laser output. Two highly efficient laser modules and a 90° quartz rotator for birefringence compensation were used for the high output power. The maximum average output power of 62.5 W with the beam quality factor M(2) of 1.15 was achieved under a pump power of 216 W at a repetition rate of 500 Hz, corresponding to the optical-to-optical conversion efficiency of 28.9%. The linewidth of the laser at the maximum output power was measured to be less than 0.2 GHz.

  11. Generation of femtosecond laser pulses at 396 nm in K3B6O10Cl crystal

    International Nuclear Information System (INIS)

    Zhang Ning-Hua; Huang Hang-Dong; Tian Wen-Long; Zhu Jiang-Feng; Teng Hao; Fang Shao-Bo; Wei Zhi-Yi; Wu Hong-Ping; Pan Shi-Lie

    2016-01-01

    K 3 B 6 O 10 Cl (KBOC), a new nonlinear optical crystal, shows potential advantages for the generation of deep ultraviolet (UV) light compared with other borate crystals. In this paper we study for the first time the second harmonic generation (SHG) of a femtosecond Ti:sapphire amplifier with this crystal. Laser power is obtained to be as high as 220 mW at the central wavelength of 396 nm with a 1-mm-long crystal, and the maximum SHG conversion efficiency reaches 39.3%. The typical pulse duration is 83 fs. The results show that second harmonic (SH) conversion efficiency has the room to be further improved and that the new nonlinear crystal is very suited to generate the high efficiency deep ultraviolet laser radiation below 266 nm. (paper)

  12. High-efficency stable 213-nm generation for LASIK application

    Science.gov (United States)

    Wang, Zhenglin; Alameh, Kamal; Zheng, Rong

    2005-01-01

    213nm Solid-state laser technology provides an alternative method to replace toxic excimer laser in LASIK system. In this paper, we report a compact fifth harmonic generation system to generate high pulse energy 213nm laser from Q-switched Nd:YAG laser for LASIK application based on three stages harmonic generation procedures. A novel crystal housing was specifically designed to hold the three crystals with each crystal has independent, precise angular adjustment structure and automatic tuning control. The crystal temperature is well maintained at ~130°C to improve harmonic generation stability and crystal operation lifetime. An output pulse energy 35mJ is obtained at 213nm, corresponding to total conversion efficiency ~10% from 1064nm pump laser. In system verification tests, the 213nm output power drops less than 5% after 5 millions pulse shots and no significant damage appears in the crystals.

  13. DNA damages induced by Ar F laser

    Energy Technology Data Exchange (ETDEWEB)

    Chapel, C.; Rose, S.; Chevrier, L.; Cordier, E.; Courant, D. [CEA Fontenay-aux-Roses, 92 (France). Dept. de Radiobiologie et de Radiopathologie

    2006-07-01

    The photo ablation process used in corneal refractive surgery by the Argon Fluoride (Ar F) laser emitting in ultraviolet C at 193 nm, exposes viable cells round the irradiated zone to sub ablative doses (< 400 joules.m -2). Despite that DNA absorption is higher at 193 nm than 254 nm, cytotoxicity of 193 nm laser radiation is lower than radiation emitted by 254 nm UV-C lamps. In situ, DNA could be protected of laser radiation by cellular components. Consequently, some authors consider that this radiation does not induce genotoxic effect whereas others suspect it to be mutagenic. These lasers are used for fifteen years but many questions remain concerning the long term effects on adjacent cells to irradiated area. The purpose of this study is to describe the effect of 193 nm laser radiation on DNA of stromal keratocytes which are responsible of the corneal structure. The 193 nm laser irradiation induces directly DNA breakage in keratocytes as it has been shown by the comet assay under alkaline conditions. Two hours post irradiation, damages caused by the highest exposure (150 J.m-2) are not repaired as it has been measured with the Olive Tail Moment (product of tail length and tail DNA content). They give partly evidence of induction of an apoptotic process in cells where DNA could be too damaged. In order to characterize specifically double strand breaks, a comparative analysis by immunofluorescence of the H2 Ax histone phosphorylation (H2 Ax) has been performed on irradiated keratocytes and unirradiated keratocytes. Results show a dose dependent increase of the number of H2 Ax positive cells. Consequences of unrepaired DNA lesions could be observed by the generation of micronuclei in cells. Results show again an increase of micronuclei in laser irradiated cells. Chromosomal aberrations have been pointed out by cytogenetic methods 30 mn after irradiation. These aberrations are dose dependent (from 10 to 150 J.m-2). The number of breakage decreases in the long run

  14. Modeled occupational exposures to gas-phase medical laser-generated air contaminants.

    Science.gov (United States)

    Lippert, Julia F; Lacey, Steven E; Jones, Rachael M

    2014-01-01

    Exposure monitoring data indicate the potential for substantive exposure to laser-generated air contaminants (LGAC); however the diversity of medical lasers and their applications limit generalization from direct workplace monitoring. Emission rates of seven previously reported gas-phase constituents of medical laser-generated air contaminants (LGAC) were determined experimentally and used in a semi-empirical two-zone model to estimate a range of plausible occupational exposures to health care staff. Single-source emission rates were generated in an emission chamber as a one-compartment mass balance model at steady-state. Clinical facility parameters such as room size and ventilation rate were based on standard ventilation and environmental conditions required for a laser surgical facility in compliance with regulatory agencies. All input variables in the model including point source emission rates were varied over an appropriate distribution in a Monte Carlo simulation to generate a range of time-weighted average (TWA) concentrations in the near and far field zones of the room in a conservative approach inclusive of all contributing factors to inform future predictive models. The concentrations were assessed for risk and the highest values were shown to be at least three orders of magnitude lower than the relevant occupational exposure limits (OELs). Estimated values do not appear to present a significant exposure hazard within the conditions of our emission rate estimates.

  15. Improved photochemotherapy of malignant cells with daunomycin and the KTP laser.

    Science.gov (United States)

    Paiva, M B; Saxton, R E; Graeber, I P; Jongewaard, N; Eshraghi, A A; Suh, M J; Paek, W H; Castro, D J

    1998-01-01

    Laser photochemotherapy of malignancies may become an effective palliative treatment for advanced had and neck cancer using light-sensitive, chemotherapeutic drugs activated in tumors via interstitial laser fiberoptics. Previously, it was reported that cultured human P3 squamous cells incubated 2 hours with daunomycin (Dn) exhibited tenfold enhanced cytotoxicity after exposure to argon laser light at 514 nm. This short-term uptake leads to drug localization in cytoplasmic and membrane sites prior to nuclear accumulation and daunomycin topoisomerase inhibition. In the current study phototoxicity of Dn-sensitized human cancer cells was tested using broad-spectrum white light compared to monochromatic green-wavelength light. Drug uptake and laser energy levels were optimized for maximum synergy. To test light-enhanced chemotherapy in vitro, the kinetics of cell uptake and toxicity of daunomycin was measured at 1, 2, and 5 microg/ml in three human tumor cell lines: P3 squamous-cell carcinoma, M26 melanoma, and TE671 fibrosarcoma. After 2 hr Dn uptake, all cell lines were tested for phototherapy response by exposure to 300- to 900-nm visible light from a xenon lamp or monochromatic 532-nm green light from a KTP laser. When the KTP laser output was varied from 0 to 120 Joules in Dn-sensitized tumor cells, a linear phototherapy response was seen with energy as low as 12 J inducing drug phototoxicity. These results provide evidence that daunomycin cytotoxicity is enhanced when exposed to 532-nm laser illumination in the three tumor types tested and confirm that the response is related to both energy level and drug dose.

  16. DNA damage in cultured human skin fibroblasts exposed to excimer laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    Rimoldi, D.; Miller, A.C.; Freeman, S.E.; Samid, D. (Department of Pathology, Uniformed Services University of the Health Sciences, Bethesda, MD (USA))

    1991-06-01

    Ultraviolet excimer lasers are being considered for use in a variety of refractive and therapeutic procedures, the long-term biologic consequences of which are unknown. The effect of sublethal doses of 193-nm laser radiation on cellular DNA was examined in cultured human skin fibroblasts. In contrast to 248 nm, treatments with the 193-nm laser radiation below 70 J/m2 did not cause significant pyrimidine dimer formation in the skin cells. This was indicated by the lack of excision repair activities (unscheduled DNA synthesis assay), and further demonstrated by direct analysis of pyrimidine dimers in DNA from irradiated cells. However, a low level of unscheduled DNA synthesis could be detected following irradiation at 193 nm with 70 J/m2. Both the 193-nm and 248-nm radiation were able to induce chromosomal aberrations, as indicated by a micronucleus assay. A dose-dependent increase in micronuclei frequency was observed 48 and 72 h after laser irradiation. These results indicate that exposure of actively replicating human skin fibroblasts to sublethal doses of either 193- or 248-nm laser radiation can result in genotoxicity.

  17. [The 308 nm Excimer laser for the treatment of psoriasis and inflammatory skin diseases].

    Science.gov (United States)

    Fritz, K; Salavastru, C

    2018-01-01

    Overall, the 308 nm Excimer laser enables not only a more effective and safer UVB therapy than classical UV phototherapy, but also targeted irradiation in higher doses with a lower cumulative load, which results in faster healing of mainly circumscribed skin changes. This also applies to therapy-resistant residual lesions which, despite systemic therapy, did not diminish. Combination therapies usually improve the result and enable the dose of UVB and systemic medication to be reduced. Excimer laser therapy can be used for an increasing number of skin diseases, especially those that respond to phototherapy or photochemotherapy.

  18. Generation of 275.4-nm UV output from a large-frame argon-ion laser for fluorescence detection in capillary electrophoresis.

    NARCIS (Netherlands)

    Kok, S.J.; de Ridder, T.; Brinkman, U.A.T.; Velthorst, N.H.; Gooijer, C.; Hoornweg, G.Ph.

    1998-01-01

    A standard, relatively old, large-frame argon-ion laser, which is available in many laboratories, was modified to produce output in the deep- UV (275-306 nm) region by installing a set of inexpensive, commercially available laser mirrors. The deep-UV output is generally applicable as excitation

  19. Time-resolved analysis of thickness-dependent dewetting and ablation of silver films upon nanosecond laser irradiation

    International Nuclear Information System (INIS)

    Qi, Dongfeng; Paeng, Dongwoo; Yeo, Junyeob; Kim, Eunpa; Wang, Letian; Grigoropoulos, Costas P.; Chen, Songyan

    2016-01-01

    Nanosecond pulsed laser dewetting and ablation of thin silver films is investigated by time-resolved imaging. Laser pulses of 532 nm wavelength and 5 ns temporal width are irradiated on silver films of different thicknesses (50 nm, 80 nm, and 350 nm). Below the ablation threshold, it is observed that the dewetting process does not conclude until 630 ns after the laser irradiation for all samples, forming droplet-like particles in the spot central region. At higher laser intensities, ablative material removal occurs in the spot center. Cylindrical rims are formed in the peripheral dewetting zone due to the solidification of transported matter at about 700 ns following the laser pulse exposure. In addition to these features, droplet fingers are superposed upon irradiation of 350-nm thick silver films with higher intensity.

  20. Time-resolved analysis of thickness-dependent dewetting and ablation of silver films upon nanosecond laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Dongfeng [Laser Thermal Laboratory, Department of Mechanical Engineering, University of California, Berkeley, California 94720-1740 (United States); Semiconductor Photonics Research Center, Department of Physics, Xiamen University, Xiamen 361005 (China); Paeng, Dongwoo; Yeo, Junyeob; Kim, Eunpa; Wang, Letian; Grigoropoulos, Costas P., E-mail: cgrigoro@berkeley.edu [Laser Thermal Laboratory, Department of Mechanical Engineering, University of California, Berkeley, California 94720-1740 (United States); Chen, Songyan [Semiconductor Photonics Research Center, Department of Physics, Xiamen University, Xiamen 361005 (China)

    2016-05-23

    Nanosecond pulsed laser dewetting and ablation of thin silver films is investigated by time-resolved imaging. Laser pulses of 532 nm wavelength and 5 ns temporal width are irradiated on silver films of different thicknesses (50 nm, 80 nm, and 350 nm). Below the ablation threshold, it is observed that the dewetting process does not conclude until 630 ns after the laser irradiation for all samples, forming droplet-like particles in the spot central region. At higher laser intensities, ablative material removal occurs in the spot center. Cylindrical rims are formed in the peripheral dewetting zone due to the solidification of transported matter at about 700 ns following the laser pulse exposure. In addition to these features, droplet fingers are superposed upon irradiation of 350-nm thick silver films with higher intensity.

  1. 4 Gbps direct modulation of 450 nm GaN laser for high-speed visible light communication

    KAUST Repository

    Lee, Changmin; Zhang, Chong; Cantore, Michael; Farrell, Robert M.; Oh, Sang Ho; Margalith, Tal; Speck, James S.; Nakamura, Shuji; Bowers, John E.; DenBaars, Steven P.

    2015-01-01

    We demonstrate high-speed data transmission with a commercial high power GaN laser diode at 450 nm. 2.6 GHz bandwidth was achieved at an injection current of 500 mA using a high-speed visible light communication setup. Record high 4 Gbps free

  2. Scanning vs. single spot laser ablation (λ=213 nm) inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Gonzalez, Jhanis J.; Fernandez, Alberto; Mao Xianglei; Russo, Richard E.

    2004-01-01

    Sampling strategy is defined in this work as the interaction of a repetitively pulsed laser beam with a fixed position on a sample (single spot) or with a moving sample (scan). Analytical performance of these sampling strategies was compared by using 213 nm laser ablation ICP-MS. A geological rock (Tuff) was quantitatively analyzed based on NIST series 610-616 glass standard reference materials. Laser ablation data were compared to ICP-MS analysis of the dissolved samples. The scan strategy (50 μm/s) produced a flat, steady temporal ICP-MS response whereas the single spot strategy produced a signal that decayed with time (after 60 s). Single-spot sampling provided better accuracy and precision than the scan strategy when the first 15 s of the sampling time was eliminated from the data analysis. In addition, the single spot strategy showed less matrix dependence among the four NIST glasses

  3. Toxicity of laser irradiated photoactive fluoride PrF3 nanoparticles toward bacteria

    International Nuclear Information System (INIS)

    Pudovkin, M S; Korableva, S L; Krasheninnicova, A O; Nizamutdinov, A S; Semashko, V V; Zelenihin, P V; Alakshin, E M; Nevzorova, T A

    2014-01-01

    The article is devoted to exploration of biological effects of crystalline PrF 3 nanoparticles toward Salmonella typhimurium TA 98 bacteria under the laser irradiation. Obtained results show bactericidal activity of PrF 3 nanoparticles and optimal parameters of laser irradiation (power of laser irradiation, wavelength, diameter of the laser spoil, and exposure time) have been found under which the effects of bactericidal activity become the most significant. Survival of bacterial cells under laser irradiation with wavelength 532 nm in colloidal solution of PrF 3 nanoparticles was 39%, 34%, 20% for exposure times 5 minutes, 15 minutes and 30 minutes, correspondingly

  4. Cytogenetic studies with laser or X-ray exposures

    International Nuclear Information System (INIS)

    Bozduganov, A.; Genkov, P.

    1975-01-01

    Account is given of studies involving a total of 21 peripheral blood cultures given the following treatments: exposure to 20 0.13-joule pulses from an optic quantum generator (ruby), 9; exposure to 1000 R X-rays, 9; and unexposed controls, 3. Exposures were carried out on three cultures from each experimental series at each of three time intervals, namely 24 h, 48 h, and 72 h after initiation of cultures. On any day, 40 well-spread metaphases were examined. High quality metaphases were photographed and karyotyped in conformity to the Chicago Conference criteria. In the laser experiment, chromosome aberrations were observed in 65% of methaphases analyzed vs. 5.3% in controls. Anomalies encountered included aneuploidy, with hypoploid metaphases predominating, polyploidy (triploidy, tetraploidy, and partial endoreduplication), and structural alterations. The following structural chromosome rearrangements are found: acentric fragments, mostly pairs, occasionally single, including minute chromosomes; dicentric and tricentric chromosomes; interstitial deletions; and chromosome translocations. Most varied and abundant chromosome aberrations were seen in 72-h irradiated cultures. The data presented offer a new opportunity for assessing genetic lesions after laser exposure and may help to determine threshold doses. (author)

  5. 205 nm continuous-wave laser: application to the measurement of the Lamb shift in hydrogen

    International Nuclear Information System (INIS)

    Bourzeix, S.

    1995-01-01

    The subject of this thesis is the construction of an experimental set-up, and in particular of a tunable continuous-wave laser at 205 nm, for the measurement of the ground state Lamb shift in atomic hydrogen. Chapter 1 deals with the Lamb shift from a historical point of view, and with the interest of its measurement, for metrology and test of quantum electrodynamics. Chapter 2 is devoted to the theory of the hydrogen atom. The principle of the experiment is based on the comparison of two frequencies which are in a ratio of 4: those of the two-photon transitions of 2S-6S or 2S-6D and 1S-3S. Chapter 3 describes the experimental set-up used to measure the 2S-6D transition which is excited by a titanium-sapphire laser at 820 nm. The 205 nm light required to excite the 1S-3S transition is generated by two frequency-doubling of the titanium-sapphire laser, made in non-linear crystals placed in enhancement cavities. Chapter 4 is entirely devoted to the frequency-doubling. After a recall of non-linear optics, the enhancement cavities are described in detail, as well as the results we achieved. At last chapter 5 describes the research for a signal on the 1S-3S transition: the construction of a ground state atomic beam, and the development of the detection system. This work has led to a preliminary measurement of the ground state Lamb shift in atomic hydrogen: L(1S) = 8172.850 (174) MHz whose result is in very good agreement with both the previous measurements and the most recent theoretical results. (author)

  6. Organic nanostructures on silicon, created with semitransparent polystyrene spheres and 248 nm laser pulses

    International Nuclear Information System (INIS)

    Rothe, Erhard W; Manke, Charles W; Piparia, Reema; Baird, Ronald J

    2008-01-01

    Arrays of nanostructures are made starting with a template of close-packed, polystyrene spheres on a silicon surface. The spheres are either 1.091 or 2.99 μm in diameter (d) and are of polystyrene (PS). They are irradiated with a pulse of either 308 or 248 nm light to which they are transparent and semitransparent, respectively. A transparent sphere with d = 1.091 μm diameter concentrates incident light onto a small substrate area. As has been previously reported, that creates silicon nanobumps that rise from circular craters. At 248 nm and d = 2.99 μm, the light energy is mainly absorbed, destroys the sphere, and leaves a shrunken mass (typically about 500 nm wide and 100 nm high) of organic material that is probably polystyrene and its thermal degradation products. At 248 nm and d = 1.091 μm, the residual organic structures are on the order of 300 nm wide and 100 nm high. A distinctive feature is that these organic structures are connected by filaments that are on the order of 50 nm wide and 10 nm high. Filaments form because the close-packed PS spheres expand into each other during the early part of the laser pulse, and then, as the main structures shrink, their viscoelasticity leads to threads between them. Our results with 248 nm and d = 1.091 μm differ from those described by Huang et al with 248 nm and d = 1.0 μm. Future studies might include the further effect of wavelength and fluence upon the process as well the use of other materials and the replacement of nanospheres by other focusing shapes, such as ellipsoids or rods

  7. Endovenous and perivenous 808-nm laser treatment of lower limb collateral, reticular and telangiectasiac veins.

    Science.gov (United States)

    Bugiantella, Walter; Bovani, Bruno; Zini, Francesco

    2017-02-01

    Visible leg veins are not only a mere aesthetic problem, but may also be manifestation of altered microcirculation and superficial venous incompetency. Sclerotherapy is the first-line treatment for leg veins veins: the greater, the harder photothermolysis is, so that higher powers may lead to aesthetic complications. We report our experience in the treatment of small collateral (reticular and telangiectasiac veins with endovenous and perivenous 808-nm laser. Overall, 325 treatments were performed on 113 patients. The endovenous and perivenous treatment proved to be a safe, quick, well-tolerated and effective procedure. It ensured an optimal closure of the target veins right from the first treatment in most patients. Sometimes, a second treatment of the same vein was needed. The endovenous and perivenous 808-nm laser photothermal sclerosis ensures a quick coagulation-fibrosis of the veins of the lower limbs, thus allowing rapid healing and good aesthetic results (stable in 95% of patients after an average follow-up of 18 months). It may be an effective alternative to sclerotherapy.

  8. High-pulse energy supercontinuum laser for high-resolution spectroscopic photoacoustic imaging of lipids in the 1650-1850 nm region.

    Science.gov (United States)

    Dasa, Manoj Kumar; Markos, Christos; Maria, Michael; Petersen, Christian R; Moselund, Peter M; Bang, Ole

    2018-04-01

    We propose a cost-effective high-pulse energy supercontinuum (SC) source based on a telecom range diode laser-based amplifier and a few meters of standard single-mode optical fiber, with a pulse energy density as high as ~25 nJ/nm in the 1650-1850 nm regime (factor >3 times higher than any SC source ever used in this wavelength range). We demonstrate how such an SC source combined with a tunable filter allows high-resolution spectroscopic photoacoustic imaging and the spectroscopy of lipids in the first overtone transition band of C-H bonds (1650-1850 nm). We show the successful discrimination of two different lipids (cholesterol and lipid in adipose tissue) and the photoacoustic cross-sectional scan of lipid-rich adipose tissue at three different locations. The proposed high-pulse energy SC laser paves a new direction towards compact, broadband and cost-effective source for spectroscopic photoacoustic imaging.

  9. All-solid-state, synchronously pumped, ultrafast BaWO4 Raman laser with long and short Raman shifts generating at 1180, 1225, and 1323 nm

    Science.gov (United States)

    Frank, Milan; Jelínek, Michal; Kubeček, Václav; Ivleva, Lyudmila I.; Zverev, Petr G.; Smetanin, Sergei

    2017-12-01

    A lot of attention is currently focused on synchronously pumped, extra-cavity crystalline Raman lasers generating one or two Stokes Raman components in KGW or diamond Raman-active crystals, and also generating additional components of stimulated polariton scattering in lithium niobate crystal having both cubic and quadratic nonlinearities. In this contribution we report on generation of more than two Stokes components of stimulated Raman scattering with different Raman shifts in the all-solid-state, synchronously pumped, extra-cavity Raman laser based on the Raman-active a-cut BaWO4 crystal excited by a mode-locked, 220 nJ, 36 ps, 150 MHz diode sidepumped Nd:GdVO4 laser generating at the wavelength of 1063 nm. Excitation by the pumping radiation polarized along the BaWO4 crystal optical axis resulted in the Raman generation with not only usual (925cm - 1), but also additional (332cm - 1) Raman shift. Besides the 1180-nm first and 1323 nm second Stokes components with the Raman shift of 925cm - 1 from the 1063nm fundamental laser wavelength, we have achieved generation of the additional 1227 nm Raman component with different Raman shift of 332cm - 1 from the 1180nm component. At the 1227 nm component the strongest 12-times pulse shortening from 36ps down to 3ps was obtained due to shorter dephasing time of this additional Raman line (3ps for the 332-cm - 1 line instead of 6.5ps for the 925cm - 1 line). It has to be also noted that the 1225 nm generation is intracavity pumped by the 1179 nm first Stokes component resulting in the strongest pulse shortening close to the 332cm -1 line dephasing time (3ps). Slope efficiency of three Stokes components generation exceeded 20%.

  10. Diode Laser Clinical Efficacy and Mini-Invasivity in Surgical Exposure of Impacted Teeth.

    Science.gov (United States)

    Migliario, Mario; Rizzi, Manuela; Lucchina, Alberta Greco; Renò, Filippo

    2016-11-01

    The gold standard to arrange impacted teeth in the dental arch is represented by a surgical approach followed by orthodontic traction force application. In the literature, many surgical approaches are proposed to reach such a scope. The aim of the present study is to demonstrate how laser technique could positively assist surgical approaches.Study population was composed by 16 patients undergoing orthodontic treatment of 20 impacted teeth. In 10 patients (population A) surgical exposure of the impacted teeth was performed using a 980 nm diode laser, while in the other 10 patients (population B), surgical incision was performed using a traditional lancet.Only 3 patients of the population A needed local anesthesia for surgical procedure while the remaining 7 patients reported only faint pain during surgery. Two patients referred postsurgical pain (numerical rating scale average value = 2) and needed to take analgesics. None of the patients showed other postsurgical side effects (bleeding, edema).All population B patients needed infiltrative anesthesia and referred postsurgical pain (numerical rating scale average value >4) treated with analgesics. Moreover, in such population, 4 patients referred lips edema while 4 showed bleeding and 6 needed surgical sutures of soft tissues.The lack of side effects of laser surgical approach to expose impacted teeth must persuade dental practitioners to choose such a clinical approach to closed surgical approach every time it is possible.

  11. Hypericin and pulsed laser therapy of squamous cell cancer in vitro.

    Science.gov (United States)

    Bublik, Michael; Head, Christian; Benharash, Peyman; Paiva, Marcos; Eshraghi, Adrian; Kim, Taiho; Saxton, Romaine

    2006-06-01

    This in vitro study compares continuous wave and pulsed laser light at longer wavelengths for activation of the phototoxic drug hypericin in human cancer cells. Two-photon pulsed laser light now allows high-resolution fluorescent imaging of cancer cells and should provide deeper tissue penetration with near infrared light for improved detection as well as phototoxicity in human tumors. Cultured Seoul National University (SNU)-1 tumor cells from a squamous cell carcinoma (SCC) were incubated with hypericin before photoirradiation at four laser wavelengths. Phototoxicity of hypericin sensitized SCC cells was measured by dimethyl thiazoldiphenyl (MTT) tetrazolium bromide cell viability assays and by confocal fluorescence microscopy via 532-nm and infrared two-photon pulsed laser light. Phototoxic response increased linearly with hypericin dose of 0.1-2 microM, light exposure time of 5-120 sec, and pulsed dye laser wavelengths of 514-593 nm. Light energy delivery for 50% cell phototoxicity (LD50) response was 9 joules at 514 nm, 3 joules at 550 nm, and less than 1 joule at the 593 nm hypericin light absorption maxima. Fluorescence confocal microscopy revealed membrane and perinuclear localization of hypericin in the SNU cells with membrane damage seen after excitation with visible 532 nm continuous wave light or two-photon 700-950 nm picosecond pulsed laser irradiation. Hypericin may be a powerful tumor targetting drug when combined with pulsed laser light in patients with recurrent head and neck SCC.

  12. Bidirectional current triggering in planar devices based on serially connected VO2 thin films using 965 nm laser diode.

    Science.gov (United States)

    Kim, Jihoon; Park, Kyongsoo; Kim, Bong-Jun; Lee, Yong Wook

    2016-08-08

    By incorporating a 965 nm laser diode, the bidirectional current triggering of up to 30 mA was demonstrated in a two-terminal planar device based on serially connected vanadium dioxide (VO2) thin films grown by pulsed laser deposition. The bidirectional current triggering was realized by using the focused beams of laser pulses through the photo-thermally induced phase transition of VO2. The transient responses of laser-triggered currents were also investigated when laser pulses excited the device at a variety of pulse widths and repetition rates of up to 4.0 Hz. A switching contrast between off- and on-state currents was obtained as ~8333, and rising and falling times were measured as ~39 and ~29 ms, respectively, for 50 ms laser pulses.

  13. Laser-induced optical effects in triglycine-zinc chloride single crystals

    International Nuclear Information System (INIS)

    Wojciechowski, A.; Kityk, I.V.; Lakshminarayana, G.; Fuks-Janczarek, I.; Berdowski, J.; Berdowska, E.; Tylczynski, Z.

    2010-01-01

    The influence of irradiation by a cw 532 nm laser on the behavior of the absorption and optical second harmonic generation of triglicyne-zinc chloride crystal has been studied. Additional absorption bands correlate well with the time of the cw laser exposure. These lines occur at 260 nm, 305 nm, and, with small intensity, at 355 nm. The remaining part of the spectra shows substantially less changes. According to the performed quantum chemical simulations, one may expect that the observed dependences and the stability of the observed photoinduced changes are caused by formation of polarized electron-phonon states and the principal role should belong here to the electron-phonon anharmonicities, which cause the effects described by the non-polar third rank polar tensor like optical second harmonic generation. The increasing optical SHG signal shows a clear correlation with the behavior of the green laser-532 nm. It is important principal that for the blue laser-405 nm, the SHG effect is substantially less. This may reflect that the additional absorption maxima may be responsible for the non-linear optical effects. The effect demonstrates a slow time decay.

  14. Retrospective analysis of the treatment of melasma lesions exhibiting increased vascularity with the 595-nm pulsed dye laser combined with the 1927-nm fractional low-powered diode laser.

    Science.gov (United States)

    Geddes, Elizabeth R C; Stout, Ashlyn B; Friedman, Paul M

    2017-01-01

    Melasma presents a significant challenge to laser surgeons. Aggressive treatments often result in rebound melasma or post-inflammatory pigmentary alteration. Recent reports suggest melasma pathogenesis may have a vascular component. Spectrocolorimetry can detect subtle or sub-clinical telangiectatic erythema within melasma lesions. For certain patients identified by spectrocolorimetry, effective melasma treatment may include vascular-targeted therapy together with pigment-specific treatment modalities. Such combined therapies may reduce the likelihood of melasma recurrence. To evaluate the efficacy of treating melasma lesions exhibiting subtle or sub-clinical telangiectatic erythema with the 595-nm pulsed dye laser (PDL) combined with the 1927-nm fractional low-powered diode laser (FDL). A retrospective review was performed over a 2-year period as follows. Evaluated patients (n = 11) include 10 women and 1 man, average age of 38.7 years, and Fitzpatrick skin types II-IV. Each patient exhibited melasma lesions with subtle or sub-clinical telangiectatic erythema identified by spectrocolorimetry. Each underwent a series of treatments (average of four) at approximate 4-6 week intervals of the PDL followed by the FDL. Treatments were performed same-day, sequentially, with 10-15 minute interim time allowance for skin cooling. The following PDL parameters were utilized: 10 mm spot, 10-20 ms pulse duration, 7.5-8.5 J/cm 2 fluence, 30/30 DCD. Eight passes with the FDL (Clear + Brilliant ® Permea™, Solta Medical, Hayward, CA) were then performed utilizing a "low" treatment level. Clinical endpoint was mild erythema and edema. Patients were encouraged to practice strict photoprotection and apply topical skin lightening agents, but compliance was not measured. An independent physician evaluated photographs taken at baseline and at follow-up after last treatment session (average follow-up of 96 days). A quartile improvement score was used to grade the

  15. [The influence of pulsed low-intensity laser radiation of the red (635 nm) and infrared (904 nm) spectra on the human mesenchymal stem cells in vitro].

    Science.gov (United States)

    Moskvin, S V; Kliuchnikov, D Iu; Antipov, E V; Volchkov, S E; Kiseleva, O N

    2014-01-01

    Mesenchymal stem cells (MSC) have for a long time been an object of investigation with a view to elucidating the prospects for their application in clinical medicine and cosmetology. One of the approaches to the non-specific regulation of the activity of these cells at the stage of preliminary in vitro combination is the treatment with low-intensity laser radiation (LILR). The objective of the present study was to evaluate the possibility of using pulsed LILR of the infrared and red spectra for this purpose. We used the 4th passage adhesive MSC cultures based at the umbilical tissue of a donor who gave the informed consent to participate in the study. The source of illumination was a Lazmik-VLOK laser therapeutic apparatus (RU No RZN 2014/1410 dated 06.02.2014) with the matrix laser infrared radiation heads (wavelength 904 nm, light pulse length 108 ns, frequency 1500 Hz). The apparatus was operated either in the multi-frequency Lazmik regime [Moskvin S.V., 2014] with mean power density 0.05 and 0.14 mW/cm2 and the red spectrum (wavelength 635 nm, light pulse length 144 ns, frequency 1500 Hz) or in the multi-frequency Lazmik regime [Moskvin S.V., 2014] with mean power density 0.03 and 0.12. The exposition was 5 min in both regimes. The study has demonstrated that neither the morphological structure nor the viability of mesenchymal stem cells changed under the influence of energy and time parameters used in experiments. The number of cells was shown to slightly increase in comparison with control. The most pronounced effect was documented after illumination with pulse infrared (904 nm) LILR in the multi-frequency Lazmik regime. The maximum effect was observed during a period between days 1 and 3 of cultivation.

  16. 980 nm tapered lasers with photonic crystal structure for low vertical divergence

    Science.gov (United States)

    Ma, Xiaolong; Qu, Hongwei; Zhao, Pengchao; Liu, Yun; Zheng, Wanhua

    2016-10-01

    High power tapered lasers with nearly diffraction-limited beam quality have attracted much attention in numerous applications such as nonlinear frequency conversion, optical pumping of solid-state and fiber lasers, medical treatment and others. However, the large vertical divergence of conventional tapered lasers is a disadvantage, which makes beam shaping difficult and expensive in applications. Diode lasers with photonic crystal structure can achieve a large mode size and a narrow vertical divergence. In this paper, we present tapered lasers with photonic crystal structure emitting at 980 nm. The epitaxial layer is grown using metal organic chemical vapor deposition. The device has a total cavity length of 2 mm, which consists of a 400-um long ridge-waveguide section and a 1600-um long tapered section. The taper angle is 4°. An output power of 3.3 W is achieved with a peak conversion efficiency of 35% in pulsed mode. The threshold current is 240 mA and the slope efficiency is 0.78 W/A. In continuous wave mode, the output power is 2.87 W, which is limited by a suddenly failure resulting from catastrophic optical mirror damage. The far field divergences with full width at half maximum are 12.3° in the vertical direction and 2.9° in the lateral direction at 0.5 A. At high injection level the vertical divergence doesn't exceed 16°. Beam quality factor M2 is measured based on second moment definition in CW mode. High beam quality is demonstrated by M2 value of less than 2 in both vertical and lateral directions.

  17. Application of 670 nm InGaP laser and microcurrent favors the healing of second-degree burns in Wistar rats

    International Nuclear Information System (INIS)

    Belli, M; Esquisatto, M A M; Amaral, M E C; Santos, G M T; Mendonça, F A S; Fernandes, C R; Neves, L M G; Mourão, V; Barbieri, R

    2015-01-01

    The treatment of burn wounds has been a challenge due to their severity and associated multiple complications, and represents a major public health problem. This study investigated the effects of 670 nm InGaP laser irradiation and microcurrent (10 µA) stimulation on the healing of second-degree burns inflicted on the back of Wistar rats. Seventy-two animals were divided into four groups: no treatment (C); animals irradiated with a 670 nm InGaP laser (L); animals receiving microcurrent stimulation (10 µA/3 min) (MC); animals receiving 670 nm InGaP laser therapy and microcurrent stimulation (10 µA/3 min) on alternate days (MCL). Wound samples were collected on days 7, 14 and 21 of treatment for structural and morphometric analysis and for Western blotting to quantify the expression of TGF-β1 and VEGF. The applied alone and alternate of laser and microcurrent reduced the number of inflammatory cells and increased the number of newly formed vessels and fibroblasts, collagen fiber content and fiber reorganization. The two treatments also favorably modified the expression of VEGF and TGF-β1, inducing angiogenesis and decreasing the inflammation time. (paper)

  18. Fractional nonablative 1,540-nm laser resurfacing of atrophic acne scars. A randomized controlled trial with blinded response evaluation

    DEFF Research Database (Denmark)

    Hedelund, Lene; Moreau, Karen Estell R; Beyer, Ditte M

    2010-01-01

    The efficacy of nonablative fractional laser resurfacing of acne scars has been described in case reports and uncontrolled trials. The present study is the first randomized controlled trial in this field. The aim of this study was to examine the efficacy and adverse effects of 1,540-nm nonablative...... fractional laser treatment of acne scars. Ten patients with acne scars were included. Two intraindividual areas of similar size and appearance within contralateral anatomical regions were randomized to (1) 3-monthly laser treatments with a StarLux 1,540-nm fractional handpiece, and (2) no treatment. Blinded...... appeared more even and smooth than untreated control areas (4.5, 2-6.5, versus 6.5, 4.5-8, P=0.0156, at 4 weeks; 4.5, 2.5-6.5, versus 6.5, 4.5-8, at 12 weeks; P=0.0313). Patients were satisfied with the treatment (5.5, 1-7, after 12 weeks) and five of the ten patients evaluated their acne scars...

  19. Experimental study on 800 nm femtosecond laser ablation of fused silica in air and vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Shi-zhen, E-mail: xusz@uestc.edu.cn [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Yao, Cai-zhen; Liao, Wei [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Yuan, Xiao-dong, E-mail: yxd66my@163.com [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Wang, Tao [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Zu, Xiao-tao [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China)

    2016-10-15

    Ablation rates of fused silica were studied as a function of femtosecond laser pulse fluences (0.7–41 J/cm{sup 2}) in air and vacuum. The experiment was conducted by using a Ti:sapphire laser that emits radiation at 800 nm with a pulse width of 35 fs and a repetition rate of 10 Hz. The morphology and ablation depth of laser-induced damage crater were evaluated by using optical microscopy and scanning electron microscopy (SEM). Ablation rates were calculated from the depth of craters induced by multiple laser pulses. Results showed that two ablation regimes, i.e. non-thermal and thermal ablation co-existed in air and vacuum at low and moderate fluences. A drop of ablation rate was observed at high fluence (higher than 9.5 J/cm{sup 2}) in air. While in vacuum, the ablation rate increased continuously with the increasing of laser fluence and much higher than that in air. The drop of ablation rate observed at high fluence in air was due to the strong defocusing effects associated with the non-equilibrium ionization of air. Furthermore, the laser-induced damage threshold (LIDT), which was determined from the relationship between crater area and the logarithm of laser energy, was found to depend on the number of incident pulses on the same spot, and similar phenomenon was observed in air and vacuum.

  20. Dynamic exposure model analysis of continuous laser direct writing in Polar-coordinate

    Science.gov (United States)

    Zhang, Shan; Lv, Yingjun; Mao, Wenjie

    2018-01-01

    In order to exactly predict the continuous laser direct writing quality in Polar-coordinate, we take into consideration the effect of the photoresist absorbing beam energy, the Gaussian attribute of the writing beam and the dynamic exposure process, and establish a dynamic exposure model to describe the influence of the tangential velocity of the normal incident facular center and laser power on the line width and sidewall angle. Numerical simulation results indicate that while writing velocity remains unchanged, the line width and sidewall angle are all increased as the laser power increases; while laser power remains unchanged, the line width and sidewall angle are all decreased as the writing velocity increases; at the same time the line profile in the exposure section is asymmetry and the center of the line has tiny excursion toward the Polar-coordinate origin compared with the facular center. Then it is necessary to choose the right writing velocity and laser power to obtain the ideal line profile. The model makes up the shortcomings of traditional models that can only predict line width or estimate the profile of the writing line in the absence of photoresist absorption, and can be considered as an effect analysis method for optimizing the parameters of fabrication technique of laser direct writing.

  1. Resonantly diode pumped Er:YAG laser systems emitting at 1645 nm for methane detection

    International Nuclear Information System (INIS)

    Fritsche, H; Lux, O; Wang, X; Zhao, Z; Eichler, H J

    2013-01-01

    We report on the development of compact and frequency-stable Er:YAG laser systems emitting in the eye-safe spectral region. Resonant cw diode pumping provides 4.5 W output power in cw operation and 2.2 mJ in Q-switched operation with pulse duration of about 140 ns. The application of intra-cavity etalons allows for wavelength tuning from 1645.22 to 1646.33 nm while the frequency stability accounts for less than 50 MHz. The potential of the erbium laser sources in terms of methane detection was evaluated under laboratory conditions by absorption measurements employing a multi-pass absorption cell. The experimental investigations were accompanied by theoretical studies on the influence of pressure broadening on the absorption behavior of methane. (letter)

  2. Designing of Raman laser

    International Nuclear Information System (INIS)

    Zidan, M. D.; Al-Awad, F.; Alsous, M. B.

    2005-01-01

    In this work, we describe the design of the Raman laser pumped by Frequency doubled Nd-YAG laser (λ=532 nm) to generate new laser wavelengths by shifting the frequency of the Nd-YAG laser to Stokes region (λ 1 =683 nm, λ 2 =953.6 nm, λ 3 =1579.5 nm) and Antistokes region (λ ' 1 =435 nm, λ ' 2 =369.9 nm, λ ' 3=319.8 nm). Laser resonator has been designed to increase the laser gain. It consists of two mirrors, the back mirror transmits the pump laser beam (λ=532 nm) through the Raman tube and reflects all other generated Raman laser lines. Four special front mirrors were made to be used for the four laser lines λ 1 =683 nm, λ 2 =953.6 nm and λ ' 1 = 435 nm, λ ' 2 =369.9 nm. The output energy for the lines υ 1 s, υ 2 s, υ 1 as,υ 2 as was measured. The output energy of the Raman laser was characterized for different H 2 pressure inside the tube. (Author)

  3. Initial clinical results of laser prostatectomy procedure for symptomatic BPH using a new 50-watt diode laser (wavelength 1000 nm)

    Science.gov (United States)

    Bhatta, Krishna M.

    1995-05-01

    Lasers have been used for symptomatic Benign Prostatic Hyperplasia (BPH) in both contact and non-contact modes with reported success rates equivalent to that of Transurethral Resection of Prostate (TURP). A new high power diode laser (Phototome), capable of delivering up to 50 watts of 1000 nm wavelength laser power via a 1 mm quartz fiber, was used to treat 15 patients with symptomatic BPH. Five patients had acute retention, 3 had long term catheter (7 - 48 months), and 8 had severe prostatism. Spinal anesthesia was used in 11 patients, and 4 patients had local anesthesia and intravenous sedation. Four quadrant coagulation with an angle firing probe delivering 50 watts of laser power for 60 seconds in one quadrant was used as the core of the treatment in 11 patients, contact vaporization of BPH tissue was performed in one patient using a 4.5 mm ball tip was used in one patient and three patients with bladder neck stenosis had bladder neck incision performed using a 1 mm quartz fiber delivering 30 watts of laser power. A foley catheter was left indwelling and removed after 5 - 7 days. All patients except one were catheter free after a mean of 8 days. One patient continued to have severe prostatism and had a TURP performed with good results after 3 months of his laser prostatectomy procedure. AUA symptom scores available in 11 patients was found to be 4 after 1 - 3 months of the initial procedure.

  4. Gold-coated copper cone detector as a new standard detector for F2 laser radiation at 157 nm

    International Nuclear Information System (INIS)

    Kueck, Stefan; Brandt, Friedhelm; Taddeo, Mario

    2005-01-01

    A new standard detector for high-accuracy measurements of F2 laser radiation at 157 nm is presented. This gold-coated copper cone detector permits the measurement of average powers up to 2 W with an uncertainty of ∼1%. To the best of our knowledge, this is the first highly accurate standard detector for F2 laser radiation for this power level. It is fully characterized according to Guide to the Expression of Uncertainty in Measurement of the International Organization for Standardization and is connected to the calibration chain for laser radiation established by the German National Metrology Institute

  5. Chlorophyll mediated photodynamic inactivation of blue laser on Streptococcus mutans

    Science.gov (United States)

    Astuti, Suryani Dyah; Zaidan, A.; Setiawati, Ernie Maduratna; Suhariningsih

    2016-03-01

    Photodynamic inactivation is an inactivation method in microbial pathogens that utilize light and photosensitizer. This study was conducted to investigate photodynamic inactivation effects of low intensity laser exposure with various dose energy on Streptococcus mutans bacteria. The photodynamic inactivation was achieved with the addition of chlorophyll as photosensitizers. To determine the survival percentage of Streptococcus mutans bacteria after laser exposure, the total plate count method was used. For this study, the wavelength of the laser is 405 nm and variables of energy doses are 1.44, 2.87, 4.31, 5.74, 7.18, and 8.61 in J/cm2. The results show that exposure to laser with energy dose of 7.18 J/cm2 has the best photodynamic inactivation with a decrease of 78% in Streptococcus

  6. Photobiomodulation with Pulsed and Continuous Wave Near-Infrared Laser (810 nm, Al-Ga-As Augments Dermal Wound Healing in Immunosuppressed Rats.

    Directory of Open Access Journals (Sweden)

    Gaurav K Keshri

    Full Text Available Chronic non-healing cutaneous wounds are often vulnerable in one or more repair phases that prevent normal healing and pose challenges to the use of conventional wound care modalities. In immunosuppressed subject, the sequential stages of healing get hampered, which may be the consequences of dysregulated or stagnant wound inflammation. Photobiomodulation (PBM or low-level laser (light therapy (LLLT emerges as a promising drug-free, non-invasive biophysical approach for promoting wound healing, reduction of inflammation, pain and restoration of functions. The present study was therefore undertaken to evaluate the photobiomodulatory effects of 810 nm diode laser (40 mW/cm2; 22.6 J/cm2 with pulsed (10 and 100 Hz, 50% duty cycle and continuous wave on full-thickness excision-type dermal wound healing in hydrocortisone-induced immunosuppressed rats. Results clearly delineated that 810 nm PBM at 10 Hz was more effective over continuous and 100 Hz frequency in accelerating wound healing by attenuating the pro-inflammatory markers (NF-kB, TNF-α, augmenting wound contraction (α-SM actin, enhancing cellular proliferation, ECM deposition, neovascularization (HIF-1α, VEGF, re-epithelialization along with up-regulated protein expression of FGFR-1, Fibronectin, HSP-90 and TGF-β2 as compared to the non-irradiated controls. Additionally, 810 nm laser irradiation significantly increased CCO activity and cellular ATP contents. Overall, the findings from this study might broaden the current biological mechanism that could be responsible for photobiomodulatory effect mediated through pulsed NIR 810 nm laser (10 Hz for promoting dermal wound healing in immunosuppressed subjects.

  7. Eye safety report 2 (355 nm). Human risk analysis simulator for space lidars

    International Nuclear Information System (INIS)

    Schulmeister, K.; Mellerio, J.; Sonneck, G.

    2001-09-01

    This report contains the results of a risk study for a satellite based lidar mission that uses a laser in the ultraviolet wavelength range to measure atmospheric properties. A lidar can be considered as a laser radar and is an acronym for light detection and ranging. The lidar measures properties of the atmosphere by analysis of laser radiation that is directed back to the lidar. As only part of the laser radiation is scattered or absorbed by the atmosphere, the remaining laser radiation emitted from the spacecraft is incident on the earth's surface, where it might lead to injuries, especially to the eye, if biological thresholds are exceeded. For the analysed mission there is no hazard to the skin, only a potential one to the eye, but only if ocular exposure occurs with very large telescopes. The wavelength of the laser is 355 nm, which is absorbed by the cornea and lens of the eye. That is, it is not focussed onto the retina of the eye as, for instance, visible wavelengths, and therefore comparatively high levels of laser exposure, are needed to produce an injury in the lens and cornea. Because the footprint of the satellite's laser beam on the surface of the earth is so small and it moves so fast, the chance of the naked eye being exposed to the laser is small. Because of the magnification provided by an optical instrument, and the concomitant reduction in the field of view, the probability of exposure of an eye that is using such an instrument decreases with increasing optical power. However, because an increased optical power implies increased diameter of the light gathering optics, the laser energy delivered to an eye increases with instrument size so that if exposure did occur, the probability of delivering energy to the eye that exceeds the thresholds for damage increases. There are thus two conflicting processes at work for viewing with optical instruments: an increase in diameter increases the energy delivered but reduces the probability of lidar beam

  8. Laser (755 nm) and cryotherapy as depigmentation treatments for vitiligo: a comparative study.

    Science.gov (United States)

    van Geel, N; Depaepe, L; Speeckaert, R

    2015-06-01

    Depigmentation therapy can be an option in adults with extensive and refractory vitiligo. Remaining pigmented patches can be removed using depigmentation creams (monobenzyl ether of hydroquinone 20%), laser therapy or cryotherapy. In contrast to cream treatment, laser therapy and cryotherapy are fast and targeted methods, capable of destroying melanocytes selectively on one specific area. Up till now, controlled trials comparing laser and cryotherapy as depigmenting treatment in vitiligo are lacking. We performed a retrospective comparative study in 22 generalized vitiligo patients. Thirty-one pigmented test regions were exposed to cryotherapy and 20 to 755 nm laser therapy. The mean surface area per test region was 3.55 cm2 and number of treatments per test region was limited to one single session in 84.3% and varied up to four sessions (2.0%). Overall no significant difference in the capacity to induce depigmentations was observed between cryotherapy (46.7%) and laser therapy (42.9%) after one treatment. The percentage of induced depigmentation was significantly different according to the body location (P = 0.005) with best results on the trunk, followed by the arms, face, neck and less on the hands. Variables that positively influenced depigmentation results were a younger age of vitiligo onset (P = 0.012), skin type V (P cryotherapy and concerned mainly hyperpigmentation in the face. To our knowledge, this is the first study comparing head-to-head depigmentation strategies intra- and inter-individually. We could demonstrate that in general laser and cryotherapy are equally effective in inducing depigmentations in generalized vitiligo patients. Retreatment of the same area may be required in case of initial failure. © 2014 European Academy of Dermatology and Venereology.

  9. Comparison of symmetric and asymmetric double quantum well extended-cavity diode lasers for broadband passive mode-locking at 780  nm.

    Science.gov (United States)

    Christopher, Heike; Kovalchuk, Evgeny V; Wenzel, Hans; Bugge, Frank; Weyers, Markus; Wicht, Andreas; Peters, Achim; Tränkle, Günther

    2017-07-01

    We present a compact, mode-locked diode laser system designed to emit a frequency comb in the wavelength range around 780 nm. We compare the mode-locking performance of symmetric and asymmetric double quantum well ridge-waveguide diode laser chips in an extended-cavity diode laser configuration. By reverse biasing a short section of the diode laser chip, passive mode-locking at 3.4 GHz is achieved. Employing an asymmetric double quantum well allows for generation of a mode-locked optical spectrum spanning more than 15 nm (full width at -20  dB) while the symmetric double quantum well device only provides a bandwidth of ∼2.7  nm (full width at -20  dB). Analysis of the RF noise characteristics of the pulse repetition rate shows an RF linewidth of about 7 kHz (full width at half-maximum) and of at most 530 Hz (full width at half-maximum) for the asymmetric and symmetric double quantum well devices, respectively. Investigation of the frequency noise power spectral density at the pulse repetition rate shows a white noise floor of approximately 2100  Hz 2 /Hz and of at most 170  Hz 2 /Hz for the diode laser employing the asymmetric and symmetric double quantum well structures, respectively. The pulse width is less than 10 ps for both devices.

  10. Compact frequency-modulation Q-switched single-frequency fiber laser at 1083 nm

    International Nuclear Information System (INIS)

    Zhang, Yuanfei; Feng, Zhouming; Xu, Shanhui; Mo, Shupei; Yang, Changsheng; Li, Can; Gan, Jiulin; Chen, Dongdan; Yang, Zhongmin

    2015-01-01

    A compact frequency-modulation Q-switched single-frequency fiber laser is demonstrated at 1083 nm. The short linear resonant cavity consists of a 12 mm long homemade Yb 3+ -doped phosphate fiber and a pair of fiber Bragg gratings (FBGs) in which the Q-switching and the frequency excursion is achieved by a tensile-induced period modulation. Over 375 MHz frequency-tuning range is achieved with a modulation frequency varying from tens to hundreds of kilohertz. The highest peak power of the output pulse reaching 6.93 W at the repetition rate of 10 kHz is obtained. (paper)

  11. Low-level laser therapy with 940 nm diode laser on stability of dental implants: a randomized controlled clinical trial.

    Science.gov (United States)

    Torkzaban, Parviz; Kasraei, Shahin; Torabi, Sara; Farhadian, Maryam

    2018-02-01

    Low-level laser therapy (LLLT) is a non-invasive modality to promote osteoblastic activity and tissue healing. The aim of this study was to evaluate the efficacy of LLLT for improvement of dental implant stability. This randomized controlled clinical trial was performed on 80 dental implants placed in 19 patients. Implants were randomly divided into two groups (n = 40). Seven sessions of LLLT (940 nm diode laser) were scheduled for the test group implants during 2 weeks. Laser was irradiated to the buccal and palatal sides. The same procedure was performed for the control group implants with laser hand piece in "off" mode. Implant stability was measured by Osstell Mentor device in implant stability quotient (ISQ) value immediately after surgery and 10 days and 3, 6, and 12 weeks later. Repeated measures ANOVA was used to compare the mean ISQ values (implant stability) in the test and control groups. Statistical test revealed no significant difference in the mean values of implant stability between the test and control groups over time (P = 0.557). Although the mean values of implant stability changed significantly in both groups over time (P laser group in the first weeks and increased from the 6th to 12th week, LLLT had no significant effect on dental implant stability.

  12. Pulsed 1064 nm Nd-YAG Laser Deposition of Titanium on Silicon in a Nitrogen Environment

    Directory of Open Access Journals (Sweden)

    Wilson Garcia

    1999-12-01

    Full Text Available Pulsed laser deposition (PLD technique was demonstrated for the deposition of titanium nitride (TiN thin films on Si (100 substrates. A 1064 nm pulsed Nd-YAG laser is focused on a titanium (99.5% target in a nitrogen environment to generate the atomic flux needed for the film deposition. Spectroscopic analysis of the plasma emission indicates the presence of atomic titanium and nitrogen, which are the precursors of TiN. Images of the films grown at different laser pulse energies show an increase in the number and size of deposited droplets and clusters with increasing laser pulse energy. A decrease in cluster and droplet size is also observed, with an increase in substrate temperature. EDS data show an increase in the titanium peak relative to the silicon as the ambient nitrogen pressure is decreased. An increase in deposition time was found to result in large clusters and irregularly shaped structures on the substrate. Post-deposition annealing of the samples enhanced the crystallinity of the film.

  13. RFA-based 589-nm guide star lasers for ESO VLT: a paradigm shift in performance, operational simplicity, reliability, and maintenance

    Science.gov (United States)

    Friedenauer, Axel; Karpov, Vladimir; Wei, Daoping; Hager, Manfred; Ernstberger, Bernhard; Clements, Wallace R. L.; Kaenders, Wilhelm G.

    2012-07-01

    Large telescopes equipped with adaptive optics require 20-25W CW 589-nm sources with emission linewidths of ~5 MHz. These Guide Star (GS) lasers should also be highly reliable and simple to operate and maintain for many years at the top of a mountain facility. Under contract from ESO, industrial partners TOPTICA and MPBC are nearing completion of the development of GS lasers for the ESO VLT, with delivery of the first of four units scheduled for December 2012. We report on the design and performance of the fully-engineered Pre-Production Unit (PPU), including system reliability/availability analysis, the successfully-concluded qualification testing, long-term component and system level tests and long-term maintenance and support planning. The chosen approach is based on ESO's patented narrow-band Raman Fiber Amplifier (EFRA) technology. A master oscillator signal from a linearly-polarized TOPTICA 20-mW, 1178-nm CW diode laser, with stabilized emission frequency and controllable linewidth up to a few MHz, is amplified in an MPBC polarization-maintaining (PM) RFA pumped by a high-power 1120-nm PM fiber laser. With efficient stimulated Brillouin scattering suppression, an unprecedented 40W of narrow-band RFA output has been obtained. This is then mode-matched into a resonant-cavity doubler with a free-spectral-range matching the sodium D2a to D2b separation, allowing simultaneous generation of an additional frequency component (D2b line) to re-pump the sodium atom electronic population. With this technique, the return flux can be increased without having to resort to electro-optical modulators and without the risk of introducing optical wave front distortions. The demonstrated output powers with doubling efficiencies >80% at 589 nm easily exceed the 20W design goal and require less than 700 W of electrical power. In summary, the fiber-based guide star lasers provide excellent beam quality and are modular, turn-key, maintenance-free, reliable, efficient, and ruggedized

  14. Thermal investigation on high power dfb broad area lasers at 975 nm, with 60% efficiency

    Science.gov (United States)

    Mostallino, R.; Garcia, M.; Deshayes, Y.; Larrue, A.; Robert, Y.; Vinet, E.; Bechou, L.; Lecomte, M.; Parillaud, O.; Krakowski, M.

    2016-03-01

    The demand of high power diode lasers in the range of 910-980nm is regularly growing. This kind of device for many applications, such as fiber laser pumping [1], material processing [1], solid-state laser pumping [1], defense and medical/dental. The key role of this device lies in the efficiency (𝜂𝐸) of converting input electrical power into output optical power. The high value of 𝜂𝐸 allows high power level and reduces the need in heat dissipation. The requirement of wavelength stabilization with temperature is more obvious in the case of multimode 975nm diode lasers used for pumping Yb, Er and Yb/Er co-doped solid-state lasers, due to the narrow absorption line close to this wavelength. Such spectral width property (etching and re-growth process techniques, is achievable in high power diode lasers using optical feedback. This paper reports on the development of the diode laser structure and the process techniques required to write the gratings taking into account of the thermal dissipation and optical performances. Performances are particularly determined in terms of experimental electro-optical characterizations. One of the main objectives is to determine the thermal resistance of the complete assembly to ensure the mastering of the diode laser temperature for operating condition. The classical approach to determine junction temperature is based on the infrared thermal camera, the spectral measurement and the pulse electrical method. In our case, we base our measurement on the spectral measurement but this approach is not well adapted to the high power diodes laser studied. We develop a new measurement based on the pulse electrical method and using the T3STERequipment. This method is well known for electronic devices and LEDs but is weakly developed for the high power diodes laser. This crucial measurement compared to spectral one is critical for understand the thermal management of diode laser device and improve the structure

  15. Direct Write Processing of Multi-micron Thickness Copper Nano-particle Paste on Flexible Substrates with 532 nm Laser Wavelength

    Science.gov (United States)

    Lopez-Espiricueta, Dunia; Fearon, Eamonn; Edwardson, Stuart; Dearden, Geoffrey

    The Laser Assisted Direct Write (LA-DW) method has been implemented in the development of different markets and material processing, recently also used for creating Printed Circuit Boards (PCB) or electrical circuitry. The process consists in the deposition of metallic nano-particle (NP) inks, which are afterwards cured or sintered by laser irradiation, thus creating conductive pathways; advantages are speed, accuracy and the protection of the heat affected zone (HAZ). This research will study the behaviour of the heat dissipation relatively within the Nano-particle Copper paste after being irradiated with 1064 nm and 532 nm wavelengths, research will be developed on different widths and depths deposited onto flat surfaces such as flexible PET. Comparisons to be made between resistivity results obtained from different wavelengths.

  16. High-power 355 nm ultraviolet lasers operating at ultrahigh repetition rate

    International Nuclear Information System (INIS)

    Chen, H; Liu, Q; Yan, P; Gong, M

    2013-01-01

    In this letter, we demonstrate a novel 355 nm ultraviolet (UV) laser operating at ultrahigh repetition rate from 300 kHz to 1 MHz. The hybrid fiber-MOPA–bulk amplifiers based IR source exhibits a high average power of 105 W with near-diffraction-limited beam quality, narrow linewidth and high polarization extinction ratio. Two-cascaded LBO crystals are employed for high efficiency frequency tripling, and a maximum 43.7 W of average UV power is achieved at 400 kHz, corresponding to a conversion efficiency as high as 41.6%. The pulse duration of the UV pulse can be tuned from 5 to 10 ns with good pulse peak stability (better than 2.2% (RMS)). (letter)

  17. Laser de baixa intensidade (830 nm na recuperação funcional do nervo isquiático de ratos Low intensity laser (830 nm functional to recover of the sciatic nerve in rats

    Directory of Open Access Journals (Sweden)

    Alexandre Marcio Marcolino

    2010-01-01

    Full Text Available OBJETIVO: Avaliar o efeito do laser de baixa intensidade na melhora funcional da marcha de ratos após esmagamento do nervo ciático. MÉTODOS: Foram utilizados 18 ratos divididos alea-to-riamente em dois grupos: controle (sham e irradiado com densidade de energia de 40J/cm², em 21 dias consecutivos, utilizando o laser 830nm (AsGaAl. Os animais foram submetidos ao esmagamento do nervo ciático direito com o dispositivo portátil de peso morto e avaliados pelo "Índice Funcional do Ciático" (IFC. As pegadas foram coletadas no pré-operatório, 7º, 14º e 21º dias pós-operatório. RESULTADOS: Os resultados do IFC foram significantes quando comparados os grupos no 7º e 14º dia pós-operatório (pOBJECTIVE: This study aimed to evaluate the effect of low-intensity laser on functional improvement of the walking of rats after sciatic nerve axonotmesis. METHODS: We used 18 rats divided randomly in two groups: control (Sham and irradiated with an energy density of 40J/cm² for 21 consecutive days, using 830nm laser (AsGaAl. The animals were subjected to right sciatic nerve crushing by a portable device and assessed by the "Sciatic Functional Index" (SFI at an acrylic platform through video recorded by a digital camera. The footprints were collected preoperatively, and on the 7th, 14th and 21st postoperative days. RESULTS: The results of the SFI were significant when comparing the groups on the 7th and 14th postoperative day (p<0.05. On the 21st postoperative day there was no difference between groups. There were intra-group differences detected in each evaluated week (p<0.01. The irradiated animals showed improvement in motion pattern, shown by the SFI values in the initial periods, but after 3 weeks, there was a similar recovery. CONCLUSION: The low-intensity laser has shown to be effective in accelerating regeneration of the sciatic nerve of rats after crushing.

  18. A new nanosecond UV laser at 355 nm: early results of corneal flap cutting in a rabbit model.

    Science.gov (United States)

    Trost, Andrea; Schrödl, Falk; Strohmaier, Clemens; Bogner, Barbara; Runge, Christian; Kaser-Eichberger, Alexandra; Krefft, Karolina; Vogel, Alfred; Linz, Norbert; Freidank, Sebastian; Hilpert, Andrea; Zimmermann, Inge; Grabner, Günther; Reitsamer, Herbert A

    2013-12-03

    A new 355 nm UV laser was used for corneal flap cutting in an animal model and tested for clinical and morphologic alterations. Corneal flaps were created (Chinchilla Bastards; n = 25) with an UV nanosecond laser at 355 nm (150 kHz, pulse duration 850 ps, spot-size 1 μm, spot spacing 6 × 6 μm, side cut Δz 1 μm; cutting depth 130 μm) and pulse energies of 2.2 or 2.5 μJ, respectively. Following slit-lamp examination, animals were killed at 6, 12, and 24 hours after treatment. Corneas were prepared for histology (hematoxylin and eosin [HE], TUNEL-assay) and evaluated statistically, followed by ultrastructural investigations. Laser treatment was tolerated well, flap lift was easier at 2.5 μJ compared with 2.2 μJ. Standard HE at 24 hours revealed intact epithelium in the horizontal cut, with similar increase in corneal thickness at both energies. Irrespective of energy levels, TUNEL assay revealed comparable numbers of apoptotic cells in the horizontal and vertical cut at 6, 12, and 24 hours, becoming detectable in the horizontal cut as an acellular stromal band at 24 hours. Ultrastructural analysis revealed regular morphology in the epi- and endothelium, while in the stroma, disorganized collagen lamellae were detectable representing the horizontal cut, again irrespective of energy levels applied. This new UV laser revealed no epi- nor endothelial damage at energies feasible for corneal flap cutting. Observed corneal swelling was lower compared with existing UV laser studies, albeit total energy applied here was much higher. Observed loss of stromal keratinocytes is comparable with available laser systems. Therefore, this new laser is suitable for refractive surgery, awaiting its test in a chronic environment.

  19. Study on processing parameters of glass cutting by nanosecond 532 nm fiber laser

    Science.gov (United States)

    Wang, Jin; Gao, Fan; Xiong, Baoxing; Zhang, Xiang; Yuan, Xiao

    2018-03-01

    The processing parameters of soda-lime glass cutting with several nanosecond 532 nm pulsed fiber laser are studied in order to obtain sufficiently large ablation rate and better processing quality. The influences of laser processing parameters on effective cutting speed and cutting quality of 1 2 mm thick soda-lime glass are studied. The experimental results show that larger laser pulse energy will lead to higher effective cutting speed and larger maximum edge collapse of the front side of the glass samples. Compared with that of 1.1 mm thick glass samples, the 2.0 mm thick glass samples is more difficult to cut. With the pulse energy of 51.2 μJ, the maximum edge collapse is more than 200 μm for the 2.0 mm thick glass samples. In order to achieve the high effective cutting speed and good cutting quality at the same time, the dual energy overlapping method is used to obtain the better cutting performance for the 2.0 mm thick glass samples, and the cutting speed of 194 mm/s and the maximum edge collapse of less than 132 μm are realized.

  20. Absolutely calibrated vacuum ultraviolet spectra in the 150-250-nm range from plasmas generated by the NIKE KrF laser

    International Nuclear Information System (INIS)

    Seely, J.F.; Feldman, Uri; Holland, G.E.; Weaver, J.L.; Mostovych, A.N.; Obenschain, S.P.; Schmitt, A.J.; Lehmberg, R.; Kjornarattanawanich, Benjawan; Back, C.A.

    2005-01-01

    High-resolution vacuum ultraviolet (VUV) spectra were recorded from plasmas generated by the NIKE KrF laser for the purpose of observing emission from the two-plasmon decay instability (TPDI) at 2/3 the NIKE wavelength (165 nm). The targets were irradiated by up to 43 overlapping beams with intensity up to ≅10 14 W/cm 2 and with beam smoothing by induced spatial incoherence (ISI). The targets consisted of planar foils of CH, BN, Al, Si, S, Ti, Pd, and Au. Titanium-doped silica aerogels in Pyrex cylinders were also irradiated. The spectra of the target elements were observed from charge states ranging from the neutral atoms to five times ionized. The spectrometer was absolutely calibrated using synchrotron radiation, and absolute VUV plasma emission intensities were determined. Emission from the TPDI at 165-nm wavelength was not observed from any of the irradiated targets. An upper bound on the possible TPDI emission was less than 4x10 -8 the incident NIKE laser energy. The NIKE laser radiation backscattered from the silica aerogel targets at 248 nm was typically 6x10 -6 the incident NIKE laser energy, and the spectral broadening corresponded to the 1-THz bandwidth of the ISI smoothing. The spectra from the moderately charged plasma ions (up to five times ionized), spectral linewidths, absolute continuum emission level, and slope of the continuum were consistent with plasma temperatures in the 100-300-eV range

  1. The long-term effect of 1550 nm erbium:glass fractional laser in acne vulgaris.

    Science.gov (United States)

    Liu, Yale; Zeng, Weihui; Hu, Die; Jha, Smita; Ge, Qin; Geng, Songmei; Xiao, Shengxiang; Hu, Guanglei; Wang, Xiaoxiao

    2016-04-01

    We evaluated the short-term and long-term effects of the 1550 nm erbium:glass (Er:glass) fractional laser in the treatment of facial acne vulgaris. Forty-five (9 male and 36 female) acne patients were treated 4 times at 4-week intervals with the following parameters: 169 spot density and 15-30 mJ/cm(2) fluence. There was no control group. The laser spots were adjustable (maximum overlap: 20%) according to the treatment area, and delivered in rows in order to cover all the face. Clinical photographs were taken. The IGA scores and lesion counts were performed for each treatment. Their current state was obtained by phone call follow-up to determine the long-term effect and photographs were offered by themselves or taken in hospital. After four treatments, all patients had an obvious reduction of lesion counts and IGA score and the peak lesion counts decreased to 67.7% after the initial four treatment sessions. For long-term effect, 8 patients lost follow-up, hence 37 patients were followed-up. 8 patients were 2-year follow up, 27 at the 1-year follow-up, and all patients at the half-year follow-up. The mean percent reduction was 72% at the half-year follow-up, 79 at the 1-year follow-up and 75% at the 2-year follow-up. Side effects and complications were limited to transient erythema and edema, and few patients suffered from transient acne flare-ups and sensitivity. All patients responded that their skin was less prone to oiliness. In conclusion, acne can be successfully treated by 1550 nm Er:glass fractional laser, with few side effects and prolonged acne clearing.

  2. 4 Gbps direct modulation of 450 nm GaN laser for high-speed visible light communication

    KAUST Repository

    Lee, Changmin

    2015-06-10

    We demonstrate high-speed data transmission with a commercial high power GaN laser diode at 450 nm. 2.6 GHz bandwidth was achieved at an injection current of 500 mA using a high-speed visible light communication setup. Record high 4 Gbps free-space data transmission rate was achieved at room temperature.

  3. 4 Gbps direct modulation of 450 nm GaN laser for high-speed visible light communication.

    Science.gov (United States)

    Lee, Changmin; Zhang, Chong; Cantore, Michael; Farrell, Robert M; Oh, Sang Ho; Margalith, Tal; Speck, James S; Nakamura, Shuji; Bowers, John E; DenBaars, Steven P

    2015-06-15

    We demonstrate high-speed data transmission with a commercial high power GaN laser diode at 450 nm. 2.6 GHz bandwidth was achieved at an injection current of 500 mA using a high-speed visible light communication setup. Record high 4 Gbps free-space data transmission rate was achieved at room temperature.

  4. Action of a 904-nm diode laser in orthopedics and traumatology: a clinical study on 447 cases

    Science.gov (United States)

    Tam, Giuseppe

    2001-10-01

    Objective: The evidence in medical literature is that a beneficial analgesic effect can only be obtained by employing laser radiation of relatively low power density and wavelengths which are able to penetrate tissue. For this reason the semiconductor, or laser diode (GaAs, 904 nm), is the most appropriate choice in pain-reduction therapy. Summary Background Data: Low power laser (or LLL) acts on the Prostaglandins synthesis, increases the endorphins synthesis in the Rolando gelatinous substance and in the dorsal horn of the spinal cord. The L-Arginine, which is the classic substrate of nitric oxide, carries on vasodilatory and anti- inflammatory action. Methods: Treatment was carried out on 447 cases and 435 patients (250 women and 185 men) between 20th May 1987 and 31st December 1999. The patients, whose age ranged from 25 to 70, were suffering from rheumatic, degenerative and traumatic pathologies as well as cutaneous ulcers. The majority of patients had been seen by orthopaedists and rheumatologists and had undergone x-ray, ultrasound scan, etc. All patients had previously received drug-based treatment and/or physiotherapy, with poor results. Two thirds were experiencing acute symptomatic pain, while the others presented a chronic pathology with recurrent crises. We used a pulsed IR diode laser, GaAs emitting at 904 nm. Frequency of treatment: 1 application per day for 5 consecutive days, followed by a 2-day interval. The percentage reduction in symptoms or improvement in functional status were determined on the basis of objective analysis as it happens in the Legal and Insurance Medicine field. Results: Very good results were achieved especially with cases of symptomatic osteoarthritis of the cervical vertebrae, with sport-related injuries, epicondylitis, osteoarthritis of the knee, periarthritis and with cutaneous ulcers. The beneficial action of the LLLT in the latter pathology is linked to the increase in collagen and to fibroblast proliferation. The total

  5. Pulsed laser ablation of gold at 1064 nm and 532 nm

    Czech Academy of Sciences Publication Activity Database

    Torrisi, L.; Piccotto, A.; Andó, L.; Gammino, S.; Margarone, D.; Láska, Leoš; Pfeifer, Miroslav; Krása, Josef

    2004-01-01

    Roč. 54, Suppl. C (2004), s. C421-C430 ISSN 0011-4626. [Symposium on Plasma Physics and Technology /21./. Praha, 14.06.2004-17.06.2004] R&D Projects: GA AV ČR IAA1010305 Institutional research plan: CEZ:AV0Z1010921 Keywords : laser generated ions * laser plasma * diagnostics Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.292, year: 2004

  6. Determination of Pesticides by Gas Chromatography Combined with Mass Spectrometry Using Femtosecond Lasers Emitting at 267, 400, and 800 nm as the Ionization Source.

    Science.gov (United States)

    Yang, Xixiang; Imasaka, Tomoko; Imasaka, Totaro

    2018-04-03

    A standard sample mixture containing 51 pesticides was separated by gas chromatography (GC), and the constituents were identified by mass spectrometry (MS) using femtosecond lasers emitting at 267, 400, and 800 nm as the ionization source. A two-dimensional display of the GC/MS was successfully used for the determination of these compounds. A molecular ion was observed for 38 of the compounds at 267 nm and for 30 of the compounds at 800 nm, in contrast to 27 among 50 compounds when electron ionization was used. These results suggest that the ultraviolet laser is superior to the near-infrared laser for molecular weight determinations and for a more reliable analysis of these compounds. In order to study the conditions for optimal ionization, the experimental data were examined using the spectral properties (i.e., the excitation and ionization energies and absorption spectra for the neutral and ionized species) obtained by quantum chemical calculations. A few molecules remained unexplained by the currently reported rules, requiring additional rules for developing a full understanding of the femtosecond ionization process. The pesticides in the homogenized matrix obtained from kabosu ( citrus sphaerocarpa) were measured using lasers emitting at 267 and 800 nm. The pesticides were clearly separated and measured on the two-dimensional display, especially for the data measured at 267 nm, suggesting that this technique would have potential for use in the practical trace analysis of the pesticides in the environment.

  7. Non-surgical treatment of peri-implantitis with the adjunctive use of an 810-nm diode laser

    Directory of Open Access Journals (Sweden)

    Marisa Roncati

    2013-01-01

    Full Text Available An 810-nm diode laser was used to non-surgically treat a 7-mm pocket around an implant that had five threads of bone loss, BoP+, and exudate, and the patient was followed up for 5 years. Non-surgical treatment, home care reinforcement, clinical indices records, and radiographic examination were completed in two consecutive 1-h appointments within 24 h. The patient was monitored frequently for the first 3 months. Subsequently, maintenance debridement visits were scheduled at 3-month intervals. The patient had a decreased probing pocket depth and a negative BoP index compared to initial clinical data, and the results were stable after 1 year. After 5 years of follow-up visits, there appeared to be rebound of the bone level radiographically. Within the limits of this case report, conventional non-surgical periodontal therapy with the adjunctive use of an 810-nm diode laser may be a feasible alternative approach for the management of peri-implantitis. The 5-year clinical and radiographic outcomes indicated maintenance of the clinical improvement.

  8. Stable continuous-wave single-frequency Nd:YAG blue laser at 473 nm considering the influence of the energy-transfer upconversion.

    Science.gov (United States)

    Wang, Yaoting; Liu, Jianli; Liu, Qin; Li, Yuanji; Zhang, Kuanshou

    2010-06-07

    We report a continuous-wave (cw) single frequency Nd:YAG blue laser at 473 nm end-pumped by a laser diode. A ring laser resonator was designed, the frequency doubling efficiency and the length of nonlinear crystal were optimized based on the investigation of the influence of the frequency doubling efficiency on the thermal lensing effect induced by energy-transfer upconversion. By intracavity frequency doubling with PPKTP crystal, an output power of 1 W all-solid-state cw blue laser of single-frequency operation was achieved. The stability of the blue output power was better than +/- 1.8% in the given four hours.

  9. The effects of different doses of 670 nm diode laser on skin flap survival in rats O efeito de diferentes doses de laser de diodo 670 nm na viabilidade de retalho cutâneo randômico em ratos

    Directory of Open Access Journals (Sweden)

    Cristiano Schiavinato Baldan

    2012-02-01

    Full Text Available PURPOSE: To investigate the effects of different low-level laser therapy (LLLT doses on random skin flap rats. METHODS: Forty Wistar rats were randomly divided in four groups. The control group (CG was not irradiated. The experimental groups were irradiated with a diode laser 670 nm with different energies per point: group 2 (G2 with 0.06 J; group 3 (G3 0.15 J and group 4 (G4 0.57 J. The three groups were irradiated in 12 equally distributed points in the cranial skin flap portion. They were submitted to the irradiation during the immediate, first and second postoperative days. The necrosis area was evaluated in the seventh postoperative day. RESULTS: The CG shows 49.35% of necrosis area in the skin flap; G2, 39.14%; G3, 47.01% and G4, 29.17% respectively. There was a significantly difference when G4 was compared with CG`s skin flap necrosis area. CONCLUSION: The low-level laser therapy diode 670 nm with 0.57 J energy per point increases the survival in randomic skin flap rats.OBJETIVO: Investigar os efeitos de diferentes doses de laserterapia de baixa intensidade na viabilidade de retalhos cutâneos randômicos em ratos. MÉTODOS: Quarenta ratos Wistar foram randomizadamente distribuídos em quatro grupos. O grupo controle (GC não foi irradiado. Os animais dos grupos experimentais foram irradiados por laser de diodo (670 nm com as seguintes energias ofertadas por ponto: grupo 2 (G2 0,06J; grupo 3 (G3 0,15 J e grupo 4 (G4 0,57 J. Os três grupos foram irradiados em 12 pontos igualmente distribuídos na porção cranial do retalho cutâneo. Todos os animais dos grupos 2, 3 e 4 foram submetidos ao protocolo de irradiação por três dias consecutivos, iniciando no pós-operatório imediato. A área necrótica foi avaliada no sétimo dia pós-operatório. RESULTADOS: A porcentagem de área necrótica apresentou-se da seguinte forma, nos diferentes grupos: GC= 49,35%, G2= 39,14%, G3= 47,01 e G4= 29,17%. Foi encontrada diferença estatisticamente

  10. Excitation of high energy levels under laser exposure of suspensions of nanoparticles in liquids

    Energy Technology Data Exchange (ETDEWEB)

    Shafeev, G.A. [Wave Research Center of A.M. Prokhorov General Physics Institute, 38, Vavilov Street, 119991 Moscow (Russian Federation)], E-mail: shafeev@kapella.gpi.ru; Simakin, A.V. [Wave Research Center of A.M. Prokhorov General Physics Institute, 38, Vavilov Street, 119991 Moscow (Russian Federation); Bozon-Verduraz, F. [ITODYS, UMR CNRS 7086, Universite Paris 7-Denis Diderot, 2, place Jussieu, 75251 Paris cedex 05 (France); Robert, M. [Laboratoire d' Electrochimie Moleculaire, UMR CNRS 7591, Universite Paris 7 Denis Diderot, 2, place Jussieu, 75251 Paris cedex 05 (France)

    2007-12-15

    Laser exposure of suspensions of nanoparticles in liquids leads to excitation of high energy levels in both liquid and nanoparticle material. The emission spectrum of the colloidal solution under exposure of a suspension metallic nanoparticles in water to radiation of a Nd:YAG laser of a picosecond range of pulse duration is discussed. Excitation of nuclear energy levels and neutron release is experimentally studied on the model system of transmutation of Hg into Au that occurs under exposure of Hg nanodrops suspended in D{sub 2}O. The proposed mechanism involves: (i) emission of X-ray photons by Hg nanoparticles upon laser exposure, leading to neutron release from D{sub 2}O, (ii) initiation of Hg {yields} Au transmutation by the capture of neutrons. The effect of transmutation is more pronounced using {sup 196}Hg isotope instead of Hg of natural isotope composition. The influence of laser pulse duration on the degree of transmutation (from fs through ns range) is discussed.

  11. Laser hypersensitisation using 266nm light

    DEFF Research Database (Denmark)

    Sørensen, Henrik Rokkjær; Canning, J.; Kristensen, Martin

    2005-01-01

    UV hypersensitisation using CW 266 nm light on hydrogenated Ge-doped fibre is reported. The optimum sensitisation fluence is found to be in the range of 5 to 10 kJ/cm2, coinciding with previous results obtained using 355 nm light, indicating the same end-process used in the photochemical reaction...

  12. The in vitro photolysis of whole rat lenses using focused 290nm laser radiation

    International Nuclear Information System (INIS)

    Hibbard, L.B.; Kirk, N.J.; Borkman, R.F.

    1985-01-01

    Whole rat lenses have been irradiated with a UV laser at 290 or 298 nm focused to a 0.08 mm diameter spot. The irradiated spot was analyzed using fluorescence spectroscopy and it was observed that the intensity of fluorescence fell as the irradiation proceeded. These observations were interpreted in terms of a model which postulates photolysis of tryptophan, primarily present as residues in lens proteins, and formation of photoproducts which absorb the UV laser radiation to an ever-increasing extent as the irradiation proceeds. Evidence is also presented which indicates that an observed fast component of the tryptophan fluorescence decay results from local heating of the lens tissues due to energy dissipation by the laser. Tryptophan residues can be photolyzed by UV light in the whole lens, in vitro, in a fashion entirely analogous to that reported previously only for lens protein solutions. The photochemical behavior of lens protein solutions is relevant to whole lens photolysis and no special protective mechanism appears to be operative in the intact organ. (author)

  13. The dynamics of femtosecond pulsed laser removal of 20 nm Ni films from an interface

    Energy Technology Data Exchange (ETDEWEB)

    Schrider, Keegan J.; Yalisove, Steven M. [Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Torralva, Ben [Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2015-09-21

    The dynamics of femtosecond laser removal of 20 nm Ni films on glass substrates was studied using time-resolved pump-probe microscopy. 20 nm thin films exhibit removal at two distinct threshold fluences, removal of the top 7 nm of Ni above 0.14 J/cm{sup 2}, and removal of the entire 20 nm film above 0.36 J/cm{sup 2}. Previous work shows the top 7 nm is removed through liquid spallation, after irradiation the Ni melts and rapidly expands leading to tensile stress and cavitation within the Ni film. This work shows that above 0.36 J/cm{sup 2} the 20 nm film is removed in two distinct layers, 7 nm and 13 nm thick. The top 7 nm layer reaches a speed 500% faster than the bottom 13 nm layer at the same absorbed fluence, 500–2000 m/s and 300–700 m/s in the fluence ranges studied. Significantly different velocities for the top 7 nm layer and bottom 13 nm layer indicate removal from an interface occurs by a different physical mechanism. The method of measuring film displacement from the development of Newton's rings was refined so it could be shown that the 13 nm layer separates from the substrate within 70 ps and accelerates to its final velocity within several hundred picoseconds. We propose that removal of the bottom 13 nm is consistent with heterogeneous nucleation and growth of vapor at the Ni-glass interface, but that the rapid separation and acceleration of the 13 nm layer from the Ni-glass interface requires consideration of exotic phases of Ni after excitation.

  14. [Cleavage of DNA fragments induced by UV nanosecond laser excitation at 193 nm].

    Science.gov (United States)

    Vtiurina, N N; Grokhovskiĭ, S L; Filimonov, I V; Medvedkov, O I; Nechipurenko, D Iu; Vasil'ev, S A; Nechipurenko, Iu D

    2011-01-01

    The cleavage of dsDNA fragments in aqueous solution after irradiation with UV laser pulses at 193 nm has been studied. Samples were investigated using polyacrylamide gel electrophoresis. The intensity of damage of particular phosphodiester bond after hot alkali treatment was shown to depend on the base pair sequence. It was established that the probability of cleavage is twice higher for sites of DNA containing two or more successively running guanine residues. A possible mechanism of damage to the DNA molecule connected with the migration of holes along the helix is discussed.

  15. Uso do laser, 670 nm, no quadro álgico de ratos submetidos à modelo experimental de ciatalgia Use of laser, 670 nm, in painful episodes of rats submitted to experimental model of sciatica

    Directory of Open Access Journals (Sweden)

    Núbia Broetto Cunha

    2008-04-01

    Full Text Available A ciatalgia deve-se a compressão do nervo isquiático em algum ponto de seu trajeto, e seu tratamento consiste em solucionar a causa da compressão nervosa, seja por tratamento cirúrgico ou conservador. Alguns recursos fisioterapêuticos atuam basicamente na redução dos sintomas ocasionados por este distúrbio. O objetivo deste estudo foi verificar a eficácia do laser 670 nm, em duas diferentes densidades de energia, na redução do quadro álgico, em ratos submetidos a modelo experimental de ciatalgia. Foram utilizados 18 ratos, divididos em 3 grupos: G1 (n=6 submetidos à ciatalgia e simulado o tratamento (grupo placebo, G2 (n=6 submetido à ciatalgia e tratados com laser 2 J/cm², G3 (n=6 submetidos à ciatalgia e irradiados com laser 4 J/cm². O nervo isquiático do membro posterior direito dos animais foi exposto e compressão com fio catgut em 4 pontos ao redor do nervo foi realizada. No 3° dia pós-operatório, iniciou-se o tratamento com laser na região do procedimento cirúrgico do membro posterior direito durante 10 dias consecutivos. Verificou-se por meio da marcha, o tempo em que o membro permanecia no ar nos períodos: anterior à ciatalgia, pré e pós-tratamento. Os resultados demonstraram que o laser não foi eficaz na redução do quadro álgico, porém com 4 J/cm² houve efeito positivo, sem restabelecimento completo da funcionalidade.Sciatica is caused by the sciatic nerve compression in some point of its course, and its treatment consists of solving the nervous compression cause, either by surgical or conservative treatment. Some physiotherapeutic resources act basically in the reduction of the symptoms caused by this disturbance. The aim of this study was to verify the effectiveness of the laser 670 nm, in two different energy densities, in the pain reduction, in rats submitted to a sciatica experimental model. Eighteen rats, divided in 3 groups were used: G1 (n=6 submitted to sciatica and simulated treatment (placebo

  16. Efficient generation of 3.5W laser light at 515nm by frequency doubling a single-frequency high power DBR tapered diode laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Hansen, Anders Kragh; Müller, André

    2017-01-01

    More than 3.5 W of green light at 515 nm is generated by frequency doubling a single-frequency high power DBR tapered diode laser. The frequency doubling is performed in a cascade of PPMgLN and PPMgSLT crystals in order to reach high power and avoid thermal effects present in PPMgLN at high power...

  17. Diode-side-pumped continuous wave Nd³⁺ : YVO₄ self-Raman laser at 1176 nm.

    Science.gov (United States)

    Kores, Cristine Calil; Jakutis-Neto, Jonas; Geskus, Dimitri; Pask, Helen M; Wetter, Niklaus U

    2015-08-01

    Here we report, to the best of our knowledge, the first diode-side-pumped continuous wave (cw) Nd3+:YVO4 self-Raman laser operating at 1176 nm. The compact cavity design is based on the total internal reflection of the laser beam at the pumped side of the Nd3+:YVO4 crystal. Configurations with a single bounce and a double bounce of the laser beam at the pumped faced have been characterized, providing a quasi-cw peak output power of more than 8 W (multimode) with an optical conversion efficiency of 11.5% and 3.7 W (TEM00) having an optical conversion efficiency of 5.4%, respectively. Cw output power of 1.8 W has been demonstrated.

  18. Photosensitivity of the Er/Yb-Codoped Schott IOG1 Phosphate Glass Using 248 nm, Femtosecond, and Picosecond Laser Radiation

    International Nuclear Information System (INIS)

    Pissadakis, S.; Michelakaki, I.

    2009-01-01

    The effect of 248 nm laser radiation, with pulse duration of 5 picoseconds, 500 femtosecond, and 120 femtosecond, on the optical properties and the Knoop hardness of a commercial Er/Yb-codoped phosphate glass is presented here. Refractive index changes of the order of few parts of 10-4 are correlated with optical absorption centers induced in the glass volume, using Kramers-Kroning relationship. Accordingly, substantially lower refractive index changes are measured in volume Bragg gratings inscribed in the glass, indicating that, in addition to the optical density changes, volume dilation changes of negative sign may also be associated with the 248 nm ultrafast irradiation. The Knoop hardness experimental results reveal that the glass matrix undergoes an observable initial hardening and then a reversing softening and volume dilation process for modest accumulated energy doses, where the Knoop hardness follows a nonmonotonic trend. Comparative results on the Knoop hardness trend are also presented for the case of 193 nm excimer laser radiation. The above findings denote that the positive or negative evolution of refractive index changes induced by the 248 0nm ultrafast radiation in the glass is dominated by the counteraction of the color center formation and the volume modification effects.

  19. Small signal modulation characteristics of red-emitting (λ = 610 nm) III-nitride nanowire array lasers on (001) silicon

    KAUST Repository

    Jahangir, Shafat; Frost, Thomas; Hazari, Arnab; Yan, Lifan; Stark, Ethan; LaMountain, Trevor; Millunchick, Joanna M.; Ooi, Boon S.; Bhattacharya, Pallab

    2015-01-01

    The small signal modulation characteristics of an InGaN/GaN nanowire array edge- emitting laser on (001) silicon are reported. The emission wavelength is 610 nm. Lattice matched InAlN cladding layers were incorporated in the laser heterostructure for better mode confinement. The suitability of the nanowire lasers for use in plastic fiber communication systems with direct modulation is demonstrated through their modulation bandwidth of f-3dB,max = 3.1 GHz, very low values of chirp (0.8 Å) and α-parameter, and large differential gain (3.1 × 10-17 cm2).

  20. Small signal modulation characteristics of red-emitting (λ = 610 nm) III-nitride nanowire array lasers on (001) silicon

    KAUST Repository

    Jahangir, Shafat

    2015-02-16

    The small signal modulation characteristics of an InGaN/GaN nanowire array edge- emitting laser on (001) silicon are reported. The emission wavelength is 610 nm. Lattice matched InAlN cladding layers were incorporated in the laser heterostructure for better mode confinement. The suitability of the nanowire lasers for use in plastic fiber communication systems with direct modulation is demonstrated through their modulation bandwidth of f-3dB,max = 3.1 GHz, very low values of chirp (0.8 Å) and α-parameter, and large differential gain (3.1 × 10-17 cm2).