WorldWideScience

Sample records for nigrostriatal slice cultures

  1. Rat brain sagittal organotypic slice cultures as an ex vivo dopamine cell loss system.

    Science.gov (United States)

    McCaughey-Chapman, Amy; Connor, Bronwen

    2017-02-01

    Organotypic brain slice cultures are a useful tool to study neurological function as they provide a more complex, 3-dimensional system than standard 2-dimensional in vitro cell cultures. Building on a previously developed mouse brain slice culture protocol, we have developed a rat sagittal brain slice culture system as an ex vivo model of dopamine cell loss. We show that rat brain organotypic slice cultures remain viable for up to 6 weeks in culture. Using Fluoro-Gold axonal tracing, we demonstrate that the slice 3-dimensional cytoarchitecture is maintained over a 4 week culturing period, with particular focus on the nigrostriatal pathway. Treatment of the cultures with 6-hydroxydopamine and desipramine induces a progressive loss of Fluoro-Gold-positive nigral cells with a sustained loss of tyrosine hydroxylase-positive nigral cells. This recapitulates the pattern of dopaminergic degeneration observed in the rat partial 6-hydroxydopamine lesion model and, most importantly, the progressive pathology of Parkinson's disease. Our slice culture platform provides an advance over other systems, as we demonstrate for the first time 3-dimensional cytoarchitecture maintenance of rat nigrostriatal sagittal slices for up to 6 weeks. Our ex vivo organotypic slice culture system provides a long term cellular platform to model Parkinson's disease, allowing for the elucidation of mechanisms involved in dopaminergic neuron degeneration and the capability to study cellular integration and plasticity ex vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Tumor Slice Culture: A New Avatar in Personalized Oncology

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-16-1-0149 TITLE: Tumor Slice Culture: A New Avatar in Personalized Oncology PRINCIPAL INVESTIGATOR: Raymond Yeung...CONTRACT NUMBER Tumor Slice Culture: A New Avatar in Personalized Oncology 5b. GRANT NUMBER W81XWH-16-1-0149 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...10 Annual Report 2017: Tumor Slice Culture: A new avatar for personalized oncology 1. INTRODUCTION: The goal of this research is to advance our

  3. A simple method for multiday imaging of slice cultures.

    Science.gov (United States)

    Seidl, Armin H; Rubel, Edwin W

    2010-01-01

    The organotypic slice culture (Stoppini et al. A simple method for organotypic cultures of nervous tissue. 1991;37:173-182) has become the method of choice to answer a variety of questions in neuroscience. For many experiments, however, it would be beneficial to image or manipulate a slice culture repeatedly, for example, over the course of many days. We prepared organotypic slice cultures of the auditory brainstem of P3 and P4 mice and kept them in vitro for up to 4 weeks. Single cells in the auditory brainstem were transfected with plasmids expressing fluorescent proteins by way of electroporation (Haas et al. Single-cell electroporation for gene transfer in vivo. 2001;29:583-591). The culture was then placed in a chamber perfused with oxygenated ACSF and the labeled cell imaged with an inverted wide-field microscope repeatedly for multiple days, recording several time-points per day, before returning the slice to the incubator. We describe a simple method to image a slice culture preparation during the course of multiple days and over many continuous hours, without noticeable damage to the tissue or photobleaching. Our method uses a simple, inexpensive custom-built insulator constructed around the microscope to maintain controlled temperature and uses a perfusion chamber as used for in vitro slice recordings. (c) 2009 Wiley-Liss, Inc.

  4. Novel culturing platform for brain slices and neuronal cells

    DEFF Research Database (Denmark)

    Svendsen, Winnie Edith; Al Atraktchi, Fatima Al-Zahraa; Bakmand, Tanya

    2015-01-01

    In this paper we demonstrate a novel culturing system for brain slices and neuronal cells, which can control the concentration of nutrients and the waste removal from the culture by adjusting the fluid flow within the device. The entire system can be placed in an incubator. The system has been...... tested successfully with brain slices and PC12 cells. The culture substrate can be modified using metal electrodes and/or nanostructures for conducting electrical measurements while culturing and for better mimicking the in vivo conditions....

  5. Excitatory and inhibitory pathways modulate kainate excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Casaccia-Bonnefil, P; Benedikz, Eirikur; Rai, R

    1993-01-01

    In organotypic hippocampal slice cultures, kainate (KA) specifically induces cell loss in the CA3 region while N-methyl-D-aspartate induces cell loss in the CA1 region. The sensitivity of slice cultures to KA toxicity appears only after 2 weeks in vitro which parallels the appearance of mossy...... fibers. KA toxicity is potentiated by co-application with the GABA-A antagonist, picrotoxin. These data suggest that the excitotoxicity of KA in slice cultures is modulated by both excitatory and inhibitory synapses....

  6. Fluidic system for long-term in vitro culturing and monitoring of organotypic brain slices

    DEFF Research Database (Denmark)

    Bakmand, Tanya; Troels-Smith, Ane R.; Dimaki, Maria

    2015-01-01

    Brain slice preparations cultured in vitro have long been used as a simplified model for studying brain development, electrophysiology, neurodegeneration and neuroprotection. In this paper an open fluidic system developed for improved long term culturing of organotypic brain slices is presented....... The positive effect of continuous flow of growth medium, and thus stability of the glucose concentration and waste removal, is simulated and compared to the effect of stagnant medium that is most often used in tissue culturing. Furthermore, placement of the tissue slices in the developed device was studied...... by numerical simulations in order to optimize the nutrient distribution. The device was tested by culturing transverse hippocampal slices from 7 days old NMRI mice for a duration of 14 days. The slices were inspected visually and the slices cultured in the fluidic system appeared to have preserved...

  7. Organotypic hippocampal slice cultures for studies of brain damage, neuroprotection and neurorepair

    DEFF Research Database (Denmark)

    Noraberg, Jens; Poulsen, Frantz Rom; Blaabjerg, Morten

    2005-01-01

    Slices of developing brain tissue can be grown for several weeks as so-called organotypic slice cultures. Here we summarize and review studies using hippocampal slice cultures to investigate mechanisms and treatment strategies for the neurodegenerative disorders like stroke (cerebral ischemia......), Alzheimer's disease (AD) and epilepsia. Studies of non-excitotoxic neurotoxic compounds and the experimental use of slice cultures in studies of HIV neurotoxicity, traumatic brain injury (TBI) and neurogenesis are included. For cerebral ischemia, experimental models with oxygen-glucose deprivation (OGD......) and exposure to glutamate receptor agonists (excitotoxins) are reviewed. For epilepsia, focus is on induction of seizures with effects on neuronal loss, axonal sprouting and neurogenesis. For Alzheimer's disease, the review centers on the use of beta-amyloid (Abeta) in different models, while the section...

  8. Long-term brain slice culturing in a microfluidic platform

    DEFF Research Database (Denmark)

    Vedarethinam, Indumathi; Avaliani, N.; Tønnesen, J.

    2011-01-01

    In this work, we present the development of a transparent poly(methyl methacrylate) (PMMA) based microfluidic culture system for handling long-term brain slice cultures independent of an incubator. The different stages of system development have been validated by culturing GFP producing brain sli...

  9. Excitotoxic effects of non-NMDA receptor agonists in organotypic corticostriatal slice cultures

    DEFF Research Database (Denmark)

    Kristensen, B W; Noraberg, J; Jakobsen, B

    1999-01-01

    of the cytosolic enzyme lactate dehydrogenase (LDH) into the culture medium and loss of glutamic acid decarboxylase (GAD) activity in the tissue. Histological sections were also stained by the fluorescent dye Fluoro-Jade (FJ), for degenerating neurons and by immunocytochemical staining for gamma-aminobutyric acid...... density of Fluoro-Jade staining, (3) loss of GAD-activity in tissue homogenates, and (4) loss of GABA-immunostained neurons. We conclude that both differences between compounds (AMPA vs. KA) and brain areas (striatum vs. cortex) can be demonstrated in corticostriatal slice cultures, which in conjunction...... in corticostriatal slice cultures. The purpose was to examine the feasibility of these cultures for excitotoxic studies, and to demonstrate possible differential excitotoxic effects of KA and AMPA on striatal and cortical neurons. Slices of dorsolateral striatum with overlying neocortex were obtained from neonatal...

  10. Biocompatibility of silicon-based arrays of electrodes coupled to organotypic hippocampal brain slice cultures

    DEFF Research Database (Denmark)

    Kristensen, Bjarne Winther; Noraberg, J; Thiébaud, P

    2001-01-01

    by Nissl staining, Timm sulphide silver-staining, microtubule-associated protein 2 (MAP2) and glial fibrillary acidic protein (GFAP) immunostaining, the slice cultures grown on chips did not differ from conventionally grown slice cultures. Neither were there any signs of astrogliosis or neurodegeneration...

  11. Organotypic hippocampal slice culture from the adult mouse brain: a versatile tool for translational neuropsychopharmacology.

    Science.gov (United States)

    Kim, Hyunjeong; Kim, Eosu; Park, Minsun; Lee, Eun; Namkoong, Kee

    2013-03-05

    One of the most significant barriers towards translational neuropsychiatry would be an unavailability of living brain tissues. Although organotypic brain tissue culture could be a useful alternative enabling observation of temporal changes induced by various drugs in living brain tissues, a proper method to establish a stable organotypic brain slice culture system using adult (rather than neonatal) hippocampus has been still elusive. In this study, we evaluated our simple method using the serum-free culture medium for successful adult organotypic hippocampal slice culture. Several tens of hippocampal slices from a single adult mouse (3-5 months old) were cultured in serum-free versus serum-containing conventional culture medium for 30 days and underwent various experiments to validate the effects of the existence of serum in the culture medium. Neither the excessive regression of neuronal viability nor metabolic deficiency was observed in the serum-free medium culture in contrast to the serum-containing medium culture. Despite such viability, newly generated immature neurons were scarcely detected in the serum-free culture, suggesting that the original neurons in the brain slice persist rather than being replaced by neurogenesis. Key structural features of in vivo neural tissue constituting astrocytes, neural processes, and pre- and post-synapses were also well preserved in the serum-free culture. In conclusion, using the serum-free culture medium, the adult hippocampal slice culture system will serve as a promising ex vivo tool for various fields of neuroscience, especially for studies on aging-related neuropsychiatric disorders or for high throughput screening of potential agents working against such disorders. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Diffusion tensor imaging of the nigrostriatal fibers in Parkinson's disease.

    Science.gov (United States)

    Zhang, Yu; Wu, I-Wei; Buckley, Shannon; Coffey, Christopher S; Foster, Eric; Mendick, Susan; Seibyl, John; Schuff, Norbert

    2015-08-01

    Parkinson's disease (PD) is histopathologically characterized by the loss of dopamine neurons in the substantia nigra pars compacta. The depletion of these neurons is thought to reduce the dopaminergic function of the nigrostriatal pathway, as well as the neural fibers that link the substantia nigra to the striatum (putamen and caudate), causing a dysregulation in striatal activity that ultimately leads to lack of movement control. Based on diffusion tensor imaging, visualizing this pathway and measuring alterations of the fiber integrity remain challenging. The objectives were to 1) develop a diffusion tensor tractography protocol for reliably tracking the nigrostriatal fibers on multicenter data; 2) test whether the integrities measured by diffusion tensor imaging of the nigrostriatal fibers are abnormal in PD; and 3) test whether abnormal integrities of the nigrostriatal fibers in PD patients are associated with the severity of motor disability and putaminal dopamine binding ratios. Diffusion tensor tractography was performed on 50 drug-naïve PD patients and 27 healthy control subjects from the international multicenter Parkinson's Progression Marker Initiative. Tractography consistently detected the nigrostriatal fibers, yielding reliable diffusion measures. Fractional anisotropy, along with radial and axial diffusivity of the nigrostriatal tract, showed systematic abnormalities in patients. In addition, variations in fractional anisotropy and radial diffusivity of the nigrostriatal tract were associated with the degree of motor deficits in PD patients. Taken together, the findings imply that the diffusion tensor imaging characteristic of the nigrostriatal tract is potentially an index for detecting and staging of early PD. © 2015 International Parkinson and Movement Disorder Society.

  13. Organotypic brain slice cultures of adult transgenic P301S mice--a model for tauopathy studies.

    Directory of Open Access Journals (Sweden)

    Agneta Mewes

    Full Text Available BACKGROUND: Organotypic brain slice cultures represent an excellent compromise between single cell cultures and complete animal studies, in this way replacing and reducing the number of animal experiments. Organotypic brain slices are widely applied to model neuronal development and regeneration as well as neuronal pathology concerning stroke, epilepsy and Alzheimer's disease (AD. AD is characterized by two protein alterations, namely tau hyperphosphorylation and excessive amyloid β deposition, both causing microglia and astrocyte activation. Deposits of hyperphosphorylated tau, called neurofibrillary tangles (NFTs, surrounded by activated glia are modeled in transgenic mice, e.g. the tauopathy model P301S. METHODOLOGY/PRINCIPAL FINDINGS: In this study we explore the benefits and limitations of organotypic brain slice cultures made of mature adult transgenic mice as a potential model system for the multifactorial phenotype of AD. First, neonatal (P1 and adult organotypic brain slice cultures from 7- to 10-month-old transgenic P301S mice have been compared with regard to vitality, which was monitored with the lactate dehydrogenase (LDH- and the MTT (3-(4,5-Dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide assays over 15 days. Neonatal slices displayed a constant high vitality level, while the vitality of adult slice cultures decreased significantly upon cultivation. Various preparation and cultivation conditions were tested to augment the vitality of adult slices and improvements were achieved with a reduced slice thickness, a mild hypothermic cultivation temperature and a cultivation CO(2 concentration of 5%. Furthermore, we present a substantial immunohistochemical characterization analyzing the morphology of neurons, astrocytes and microglia in comparison to neonatal tissue. CONCLUSION/SIGNIFICANCE: Until now only adolescent animals with a maximum age of two months have been used to prepare organotypic brain slices. The current study

  14. Effects of chemotherapeutics on organotypic corticostriatal slice cultures identified by a panel of fluorescent and immunohistochemical markers

    DEFF Research Database (Denmark)

    Nørregaard, Annette; Jensen, Stine Skov; Kolenda, Jesper

    2012-01-01

    no toxicity was observed. Corresponding immunostaining showed loss of MAP2 and increased expression of GFAP and p25α for cultures exposed to 1,000 nM VCR. Cultures exposed to high concentrations of ACNU and IM disintegrated, leaving no tissue for histology. In conclusion, corticostriatal slice cultures...... specific neuronal and glial degeneration induced by chemotherapeutics in organotypic rat corticostriatal slice cultures. The slice cultures were exposed to the alkylating agents temozolomide (TMZ) and nimustine (ACNU), the tyrosine kinase inhibitor imatinib mesylate (IM) and the microtubule...

  15. Methods to induce primary and secondary traumatic damage in organotypic hippocampal slice cultures.

    Science.gov (United States)

    Adamchik, Y; Frantseva, M V; Weisspapir, M; Carlen, P L; Perez Velazquez, J L

    2000-04-01

    Organotypic brain slice cultures have been used in a variety of studies on neurodegenerative processes [K.M. Abdel-Hamid, M. Tymianski, Mechanisms and effects of intracellular calcium buffering on neuronal survival in organotypic hippocampal cultures exposed to anoxia/aglycemia or to excitotoxins, J. Neurosci. 17, 1997, pp. 3538-3553; D.W. Newell, A. Barth, V. Papermaster, A.T. Malouf, Glutamate and non-glutamate receptor mediated toxicity caused by oxygen and glucose deprivation in organotypic hippocampal cultures, J. Neurosci. 15, 1995, pp. 7702-7711; J.L. Perez Velazquez, M.V. Frantseva, P.L. Carlen, In vitro ischemia promotes glutamate mediated free radical generation and intracellular calcium accumulation in pyramidal neurons of cultured hippocampal slices, J. Neurosci. 23, 1997, pp. 9085-9094; L. Stoppini, L.A. Buchs, D. Muller, A simple method for organotypic cultures of nervous tissue, J. Neurosci. Methods 37, 1991, pp. 173-182; R.C. Tasker, J.T. Coyle, J.J. Vornov, The regional vulnerability to hypoglycemia induced neurotoxicity in organotypic hippocampal culture: protection by early tetrodotoxin or delayed MK 801, J. Neurosci. 12, 1992, pp. 4298-4308.]. We describe two methods to induce traumatic cell damage in hippocampal organotypic cultures. Primary trauma injury was achieved by rolling a stainless steel cylinder (0.9 g) on the organotypic slices. Secondary injury was followed after dropping a weight (0.137 g) on a localised area of the organotypic slice, from a height of 2 mm. The time course and extent of cell death were determined by measuring the fluorescence of the viability indicator propidium iodide (PI) at several time points after the injury. The initial localised impact damage spread 24 and 67 h after injury, cell death being 25% and 54%, respectively, when slices were kept at 37 degrees C. To validate these methods as models to assess neuroprotective strategies, similar insults were applied to slices at relatively low temperatures (30

  16. Organotypic slice cultures containing the preBötzinger complex generate respiratory-like rhythms

    DEFF Research Database (Denmark)

    Phillips, Wiktor S; Herly, Mikkel; Del Negro, Christopher A

    2016-01-01

    containing the preBötzinger complex (preBötC), the core inspiratory rhythm generator of the ventrolateral brainstem. We measured bilateral synchronous network oscillations, using calcium-sensitive fluorescent dyes, in both ventrolateral (presumably the preBötC) and dorsomedial regions of 7-43 days in vitro......Acute brainstem slice preparations in vitro have advanced understanding of the cellular and synaptic mechanisms of respiratory rhythm generation, but their inherent limitations preclude long-term manipulation and recording experiments. Here, we developed an organotypic slice culture preparation...... of the brainstem displayed up to 193% faster burst frequency (22.4 ± 8.3 bursts/min) and higher signal amplitude (340%) compared to acute slices. We conclude that preBötC-containing slice cultures retain inspiratory-like rhythmic function and therefore may facilitate lines of experimentation that involve extended...

  17. Ethanol induces MAP2 changes in organotypic hippocampal slice cultures

    DEFF Research Database (Denmark)

    Noraberg, J; Zimmer, J

    1998-01-01

    loss of CA3 pyramidal cells and moderate loss of dentate granule cells, as seen in vivo. The results indicate that brain slice cultures combined with immunostaining for cytoskeleton and neuronal markers can be used for studies of ethanol and organic solvent neurotoxicity.......Microtubule-associated protein 2 (MAP2) and neuron-specific protein (NeuN) immunostains were used to demonstrate neurotoxic effects in mature hippocampal slice cultures exposed to ethanol (50, 100, 200 mM) for 4 weeks. At the low dose the density of MAP2 immunostaining in the dentate molecular...... layer was 118% of the control cultures, with no detectable changes in CA1 and CA3. At 100 mM no changes were detected, while 200 mM ethanol significantly reduced the MAP2 density in both dentate (19%) and hippocampal dendritic fields (CA3, 52%; CA1, 55%). At this dose NeuN staining showed considerable...

  18. Trimethyltin (TMT) neurotoxicity in organotypic rat hippocampal slice cultures

    DEFF Research Database (Denmark)

    Noraberg, J; Gramsbergen, J B; Fonnum, F

    1998-01-01

    ) propidium iodide (PI) uptake, (b) lactate dehydrogenase (LDH) efflux into the culture medium, (c) cellular cobalt uptake as an index of calcium influx, (d) ordinary Nissl cell staining, and (e) immunohistochemical staining for microtubule-associated protein 2 (MAP-2). Cellular degeneration as assessed...... to in vivo cell stain observations of rats acutely exposed to TMT. The mean PI uptake of the cultures and the LDH efflux into the medium were highly correlated. The combined results obtained by the different markers indicate that the hippocampal slice culture method is a feasible model for further studies...

  19. GDNF and neublastin protect against NMDA-induced excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Bonde, C; Kristensen, B W; Blaabjerg, M

    2000-01-01

    -producing HiB5 cells, were added to slice cultures I h before exposure to 10 microM NMDA for 48h. Neuronal cell death was monitored, before and during the NMDA exposure, by densitometric measurements of propidium iodide (PI) uptake and loss of Nissl staining. Both the addition of rhGDNF and NBN......The potential neuroprotective effects of glial cell line-derived neurotrophic factor (GDNF) and neublastin (NBN) against NMDA-induced excitotoxicity were examined in hippocampal brain slice cultures. Recombinant human GDNF (25-100 ng/ ml) or NBN, in medium conditioned by growth of transfected, NBN...

  20. Microfluidic culture chamber for the long-term perfusion and precise chemical stimulation of organotypic brain tissue slices

    DEFF Research Database (Denmark)

    Caicedo, H. H.; Vignes, M.; Brugg, B.

    2010-01-01

    We have developed a microfluidic perfusion-based culture system to study long-term in-vitro responses of organo-typic brain slices exposed to localized neurochemical stimulation. Using this microperfusion chamber we show that hip-pocampal organotypic brain slices cultures grown on nitrocellulose ...

  1. Induksi Ginogenesis melalui Kultur Multi Ovule Slice dan Kultur Ovary Slice Dianthus chinensis

    Directory of Open Access Journals (Sweden)

    Suskandari Kartikaningrum

    2013-10-01

    Full Text Available Callus induction was studied in five genotypes of Dianthus chinensis using 2.4 D and NAA. Calluses can be obtainedfrom unfertilized ovule culture and ovary culture. The aim of the research was to study gynogenic potential and responseof Dianthus chinensis through ovule slice and ovary slice culture for obtaining haploid plants. Five genotypes of Dianthuschinensis and five media were used in ovule slice culture and two genotypes and three medium were used in ovary culture.Flower buds in the 7th stage were incubated for the purpose of dark pre-treatment at 4 oC for one day. Ovules and ovaries wereisolated and cultured in induction medium. Cultures were incubated for the purpose of dark pre-treatment at 4 oC for seven days, followed by 25 oC light incubation. The result showed that 2.4D was better than NAA in inducing callus. Percentage of regenerated calluses were produced in V11, V13 and V15 genotypes in M7 medium (MS + 2 mg L-1 2.4D + 1 mg L-1 BAP + 30 g L-1 sucrose and M10 medium (MS + 1 mg L-1 2.4D + 1 mg L-1 BAP + 20 g L-1 sucrose. All calluses originated from ovule and ovary cultures flowered prematurely. Double haploid (V11-34 were obtained from ovule slice culture based on PER (peroksidase and EST (esterase isoenzym marker.Keywords: ovule slice culture, ovary slice culture, callus, Dianthus sp., haploid

  2. Coupling of organotypic brain slice cultures to silicon-based arrays of electrodes

    DEFF Research Database (Denmark)

    Jahnsen, Henrik; Kristensen, Bjarne Winther; Thiébaud, P

    1999-01-01

    Fetal or early postnatal brain tissue can be cultured in viable and healthy condition for several weeks with development and preservation of the basic cellular and connective organization as so-called organotypic brain slice cultures. Here we demonstrate and describe how it is possible to establish...

  3. Mouse pancreas tissue slice culture facilitates long-term studies of exocrine and endocrine cell physiology in situ.

    Science.gov (United States)

    Marciniak, Anja; Selck, Claudia; Friedrich, Betty; Speier, Stephan

    2013-01-01

    Studies on pancreatic cell physiology rely on the investigation of exocrine and endocrine cells in vitro. Particularly, in the case of the exocrine tissue these studies have suffered from a reduced functional viability of acinar cells in culture. As a result not only investigations on dispersed acinar cells and isolated acini were limited in their potential, but also prolonged studies on pancreatic exocrine and endocrine cells in an intact pancreatic tissue environment were unfeasible. To overcome these limitations, we aimed to establish a pancreas tissue slice culture platform to allow long-term studies on exocrine and endocrine cells in the intact pancreatic environment. Mouse pancreas tissue slice morphology was assessed to determine optimal long-term culture settings for intact pancreatic tissue. Utilizing optimized culture conditions, cell specificity and function of exocrine acinar cells and endocrine beta cells were characterized over a culture period of 7 days. We found pancreas tissue slices cultured under optimized conditions to have intact tissue specific morphology for the entire culture period. Amylase positive intact acini were present at all time points of culture and acinar cells displayed a typical strong cell polarity. Amylase release from pancreas tissue slices decreased during culture, but maintained the characteristic bell-shaped dose-response curve to increasing caerulein concentrations and a ca. 4-fold maximal over basal release. Additionally, endocrine beta cell viability and function was well preserved until the end of the observation period. Our results show that the tissue slice culture platform provides unprecedented maintenance of pancreatic tissue specific morphology and function over a culture period for at least 4 days and in part even up to 1 week. This analytical advancement now allows mid -to long-term studies on the cell biology of pancreatic disorder pathogenesis and therapy in an intact surrounding in situ.

  4. Mouse pancreas tissue slice culture facilitates long-term studies of exocrine and endocrine cell physiology in situ.

    Directory of Open Access Journals (Sweden)

    Anja Marciniak

    Full Text Available Studies on pancreatic cell physiology rely on the investigation of exocrine and endocrine cells in vitro. Particularly, in the case of the exocrine tissue these studies have suffered from a reduced functional viability of acinar cells in culture. As a result not only investigations on dispersed acinar cells and isolated acini were limited in their potential, but also prolonged studies on pancreatic exocrine and endocrine cells in an intact pancreatic tissue environment were unfeasible. To overcome these limitations, we aimed to establish a pancreas tissue slice culture platform to allow long-term studies on exocrine and endocrine cells in the intact pancreatic environment. Mouse pancreas tissue slice morphology was assessed to determine optimal long-term culture settings for intact pancreatic tissue. Utilizing optimized culture conditions, cell specificity and function of exocrine acinar cells and endocrine beta cells were characterized over a culture period of 7 days. We found pancreas tissue slices cultured under optimized conditions to have intact tissue specific morphology for the entire culture period. Amylase positive intact acini were present at all time points of culture and acinar cells displayed a typical strong cell polarity. Amylase release from pancreas tissue slices decreased during culture, but maintained the characteristic bell-shaped dose-response curve to increasing caerulein concentrations and a ca. 4-fold maximal over basal release. Additionally, endocrine beta cell viability and function was well preserved until the end of the observation period. Our results show that the tissue slice culture platform provides unprecedented maintenance of pancreatic tissue specific morphology and function over a culture period for at least 4 days and in part even up to 1 week. This analytical advancement now allows mid -to long-term studies on the cell biology of pancreatic disorder pathogenesis and therapy in an intact surrounding in situ.

  5. Characterization of cortical neuronal and glial alterations during culture of organotypic whole brain slices from neonatal and mature mice.

    Science.gov (United States)

    Staal, Jerome A; Alexander, Samuel R; Liu, Yao; Dickson, Tracey D; Vickers, James C

    2011-01-01

    Organotypic brain slice culturing techniques are extensively used in a wide range of experimental procedures and are particularly useful in providing mechanistic insights into neurological disorders or injury. The cellular and morphological alterations associated with hippocampal brain slice cultures has been well established, however, the neuronal response of mouse cortical neurons to culture is not well documented. In the current study, we compared the cell viability, as well as phenotypic and protein expression changes in cortical neurons, in whole brain slice cultures from mouse neonates (P4-6), adolescent animals (P25-28) and mature adults (P50+). Cultures were prepared using the membrane interface method. Propidium iodide labeling of nuclei (due to compromised cell membrane) and AlamarBlue™ (cell respiration) analysis demonstrated that neonatal tissue was significantly less vulnerable to long-term culture in comparison to the more mature brain tissues. Cultures from P6 animals showed a significant increase in the expression of synaptic markers and a decrease in growth-associated proteins over the entire culture period. However, morphological analysis of organotypic brain slices cultured from neonatal tissue demonstrated that there were substantial changes to neuronal and glial organization within the neocortex, with a distinct loss of cytoarchitectural stratification and increased GFAP expression (pglial limitans and, after 14 DIV, displayed substantial cellular protrusions from slice edges, including cells that expressed both glial and neuronal markers. In summary, we present a substantial evaluation of the viability and morphological changes that occur in the neocortex of whole brain tissue cultures, from different ages, over an extended period of culture.

  6. Regulation of Axolotl (Ambystoma mexicanum) Limb Blastema Cell Proliferation by Nerves and BMP2 in Organotypic Slice Culture.

    Science.gov (United States)

    Lehrberg, Jeffrey; Gardiner, David M

    2015-01-01

    We have modified and optimized the technique of organotypic slice culture in order to study the mechanisms regulating growth and pattern formation in regenerating axolotl limb blastemas. Blastema cells maintain many of the behaviors that are characteristic of blastemas in vivo when cultured as slices in vitro, including rates of proliferation that are comparable to what has been reported in vivo. Because the blastema slices can be cultured in basal medium without fetal bovine serum, it was possible to test the response of blastema cells to signaling molecules present in serum, as well as those produced by nerves. We also were able to investigate the response of blastema cells to experimentally regulated changes in BMP signaling. Blastema cells responded to all of these signals by increasing the rate of proliferation and the level of expression of the blastema marker gene, Prrx-1. The organotypic slice culture model provides the opportunity to identify and characterize the spatial and temporal co-regulation of pathways in order to induce and enhance a regenerative response.

  7. Regulation of Axolotl (Ambystoma mexicanum Limb Blastema Cell Proliferation by Nerves and BMP2 in Organotypic Slice Culture.

    Directory of Open Access Journals (Sweden)

    Jeffrey Lehrberg

    Full Text Available We have modified and optimized the technique of organotypic slice culture in order to study the mechanisms regulating growth and pattern formation in regenerating axolotl limb blastemas. Blastema cells maintain many of the behaviors that are characteristic of blastemas in vivo when cultured as slices in vitro, including rates of proliferation that are comparable to what has been reported in vivo. Because the blastema slices can be cultured in basal medium without fetal bovine serum, it was possible to test the response of blastema cells to signaling molecules present in serum, as well as those produced by nerves. We also were able to investigate the response of blastema cells to experimentally regulated changes in BMP signaling. Blastema cells responded to all of these signals by increasing the rate of proliferation and the level of expression of the blastema marker gene, Prrx-1. The organotypic slice culture model provides the opportunity to identify and characterize the spatial and temporal co-regulation of pathways in order to induce and enhance a regenerative response.

  8. Dopaminergic differentiation of human neural stem cells mediated by co-cultured rat striatal brain slices

    DEFF Research Database (Denmark)

    Anwar, Mohammad Raffaqat; Andreasen, Christian Maaløv; Lippert, Solvej Kølvraa

    2008-01-01

    differentiation, we co-cultured cells from a human neural forebrain-derived stem cell line (hNS1) with rat striatal brain slices. In brief, coronal slices of neonatal rat striatum were cultured on semiporous membrane inserts placed in six-well trays overlying monolayers of hNS1 cells. After 12 days of co......Properly committed neural stem cells constitute a promising source of cells for transplantation in Parkinson's disease, but a protocol for controlled dopaminergic differentiation is not yet available. To establish a setting for identification of secreted neural compounds promoting dopaminergic...

  9. Electrophysiology of Hypothalamic Magnocellular Neurons In vitro: A Rhythmic Drive in Organotypic Cultures and Acute Slices.

    Science.gov (United States)

    Israel, Jean-Marc; Oliet, Stéphane H; Ciofi, Philippe

    2016-01-01

    Hypothalamic neurohormones are released in a pulsatile manner. The mechanisms of this pulsatility remain poorly understood and several hypotheses are available, depending upon the neuroendocrine system considered. Among these systems, hypothalamo-neurohypophyseal magnocellular neurons have been early-considered models, as they typically display an electrical activity consisting of bursts of action potentials that is optimal for the release of boluses of the neurohormones oxytocin and vasopressin. The cellular mechanisms underlying this bursting behavior have been studied in vitro, using either acute slices of the adult hypothalamus, or organotypic cultures of neonatal hypothalamic tissue. We have recently proposed, from experiments in organotypic cultures, that specific central pattern generator networks, upstream of magnocellular neurons, determine their bursting activity. Here, we have tested whether a similar hypothesis can be derived from in vitro experiments in acute slices of the adult hypothalamus. To this aim we have screened our electrophysiological recordings of the magnocellular neurons, previously obtained from acute slices, with an analysis of autocorrelation of action potentials to detect a rhythmic drive as we recently did for organotypic cultures. This confirmed that the bursting behavior of magnocellular neurons is governed by central pattern generator networks whose rhythmic drive, and thus probably integrity, is however less satisfactorily preserved in the acute slices from adult brains.

  10. Electrophysiology of hypothalamic magnocellular neurons in vitro: a rhythmic drive in organotypic cultures and acute slices

    Directory of Open Access Journals (Sweden)

    Jean-Marc eIsrael

    2016-03-01

    Full Text Available Hypothalamic neurohormones are released in a pulsatile manner. The mechanisms of this pulsatility remain poorly understood and several hypotheses are available, depending upon the neuroendocrine system considered. Among these systems, hypothalamo-neurohypophyseal magnocellular neurons have been early-considered models, as they typically display an electrical activity consisting of bursts of action potentials that is optimal for the release of boluses of the neurohormones oxytocin and vasopressin. The cellular mechanisms underlying this bursting behavior have been studied in vitro, using either acute slices of the adult hypothalamus, or organotypic cultures of neonatal hypothalamic tissue. We have recently proposed, from experiments in organotypic cultures, that specific central pattern generator networks, upstream of magnocellular neurons, determine their bursting activity. Here, we have tested whether a similar hypothesis can be derived from in vitro experiments in acute slices of the adult hypothalamus. To this aim we have screened our electrophysiological recordings of the magnocellular neurons, previously obtained from acute slices, with an analysis of autocorrelation of action potentials to detect a rhythmic drive as we recently did for organotypic cultures. This confirmed that the bursting behavior of magnocellular neurons is governed by central pattern generator networks whose rhythmic drive, and thus probably integrity, is however less satisfactorily preserved in the acute slices from adult brains.

  11. Protection of methamphetamine nigrostriatal toxicity by dietary selenium.

    Science.gov (United States)

    Kim, H C; Jhoo, W K; Choi, D Y; Im, D H; Shin, E J; Suh, J H; Floyd, R A; Bing, G

    1999-12-18

    Multiple dose administration of methamphetamine (MA) results in long-lasting toxic effects in the nigrostriatal dopaminergic system. These effects are considered to be primarily due to oxidative damage mediated by increased production of hydrogen peroxide or other reactive oxygen species in the dopaminergic system. The present study was designed to determine the protective effects of dietary antioxidant selenium on MA-induced neurotoxicity in the nigrostriatal dopaminergic system. Male C57BL/6J mice were fed either selenium-deficient (methamphetamine neurotoxicity and that this protection involves GPx-mediated antioxidant mechanisms. Even though Cu,Zn-SOD activity was significantly elevated by MA treatment, the role of this enzyme in MA-mediated neurotoxicity is not yet clear.

  12. Implantation of glioblastoma spheroids into organotypic brain slice cultures as a model for investigating effects of irradiation

    DEFF Research Database (Denmark)

    Petterson, Stine Asferg; Jakobsen, Ida Pind; Jensen, Stine Skov

    2016-01-01

    , models for studying the effects of radiotherapy in combination with novel strategies are lacking but important since radiotherapy is the most successful non-surgical treatment of brain tumors. The aim of this study was to establish a glioblastoma spheroid-organotypic rat brain slice culture model...... comprising both tumors, tumor-brain interface and brain tissue to provide a proof of concept that this model is useful for studying effects of radiotherapy. Organotypic brain slice cultures cultured for 1-2 days or 11-16 days corresponding to immature brain and mature brain respectively were irradiated...... with doses between 10 and 50 Gy. There was a high uptake of the cell death marker propidium iodide in the immature cultures. In addition, MAP2 expression decreased whereas GFAP expression increased in these cultures suggesting neuronal death and astrogliosis. We therefore proceeded with the mature cultures...

  13. Clinical Features Indicating Nigrostriatal Dopaminergic Degeneration in Drug-Induced Parkinsonism

    Directory of Open Access Journals (Sweden)

    Seung Ha Lee

    2017-01-01

    Full Text Available Objective Patients with drug-induced parkinsonism (DIP may have nigrostriatal dopaminergic degeneration. We studied the clinical features that may indicate nigrostriatal dopaminergic degeneration in patients with DIP. Methods Forty-one DIP patients were classified into normal and abnormal [18F] FP-CIT scan groups. Differences in 32 clinical features and drug withdrawal effects were studied. Results Twenty-eight patients had normal (Group I and 13 patients had abnormal (Group II scans. Eight patients of Group I, but none of Group II, had taken calcium channel blockers (p = 0.040. Three patients of Group I and six of Group II had hyposmia (p = 0.018. After drug withdrawal, Group I showed greater improvement in Unified Parkinson’s Disease Rating Scale total motor scores and subscores for bradykinesia and tremors than Group II. Only hyposmia was an independent factor associated with abnormal scans, but it had suboptimal sensitivity. Conclusion None of the clinical features were practical indicators of nigrostriatal dopaminergic degeneration in patients with DIP.

  14. Tumor tissue slice cultures as a platform for analyzing tissue-penetration and biological activities of nanoparticles.

    Science.gov (United States)

    Merz, Lea; Höbel, Sabrina; Kallendrusch, Sonja; Ewe, Alexander; Bechmann, Ingo; Franke, Heike; Merz, Felicitas; Aigner, Achim

    2017-03-01

    The success of therapeutic nanoparticles depends, among others, on their ability to penetrate a tissue for actually reaching the target cells, and their efficient cellular uptake in the context of intact tissue and stroma. Various nanoparticle modifications have been implemented for altering physicochemical and biological properties. Their analysis, however, so far mainly relies on cell culture experiments which only poorly reflect the in vivo situation, or is based on in vivo experiments that are often complicated by whole-body pharmacokinetics and are rather tedious especially when analyzing larger nanoparticle sets. For the more precise analysis of nanoparticle properties at their desired site of action, efficient ex vivo systems closely mimicking in vivo tissue properties are needed. In this paper, we describe the setup of organotypic tumor tissue slice cultures for the analysis of tissue-penetrating properties and biological activities of nanoparticles. As a model system, we employ 350μm thick slice cultures from different tumor xenograft tissues, and analyze modified or non-modified polyethylenimine (PEI) complexes as well as their lipopolyplex derivatives for siRNA delivery. The described conditions for tissue slice preparation and culture ensure excellent tissue preservation for at least 14days, thus allowing for prolonged experimentation and analysis. When using fluorescently labeled siRNA for complex visualization, fluorescence microscopy of cryo-sectioned tissue slices reveals different degrees of nanoparticle tissue penetration, dependent on their surface charge. More importantly, the determination of siRNA-mediated knockdown efficacies of an endogenous target gene, the oncogenic survival factor Survivin, reveals the possibility to accurately assess biological nanoparticle activities in situ, i.e. in living cells in their original environment. Taken together, we establish tumor (xenograft) tissue slices for the accurate and facile ex vivo assessment of

  15. Pilocarpine-induced seizure-like activity with increased BNDF and neuropeptide Y expression in organotypic hippocampal slice cultures

    DEFF Research Database (Denmark)

    Poulsen, Frantz Rom; Jahnsen, Henrik; Blaabjerg, Morten

    2002-01-01

    Organotypic hippocampal slice cultures were treated with the muscarinic agonist pilocarpine to study induced seizure-like activity and changes in neurotrophin and neuropeptide expression. For establishment of a seizure-inducing protocol, 2-week-old cultures derived from 6-8-day-old rats were...

  16. The GABAA receptor agonist THIP is neuroprotective in organotypic hippocampal slice cultures

    DEFF Research Database (Denmark)

    Kristensen, Bjarne Winther; Noraberg, Jens; Zimmer, Jens

    2003-01-01

    The potential neuroprotective effects of the GABA(A) receptor agonists THIP (4,5,6,7-tetrahydroisoxazolo[5,4-c]pyridin-3-ol) and muscimol, and the selective GluR5 kainate receptor agonist ATPA ((RS)-2-amino-3-(3-hydroxy-5-tert-butylisoxazol-4-yl)propanoic acid), which activates GABAergic interneu......The potential neuroprotective effects of the GABA(A) receptor agonists THIP (4,5,6,7-tetrahydroisoxazolo[5,4-c]pyridin-3-ol) and muscimol, and the selective GluR5 kainate receptor agonist ATPA ((RS)-2-amino-3-(3-hydroxy-5-tert-butylisoxazol-4-yl)propanoic acid), which activates GABAergic...... interneurons, were examined in hippocampal slice cultures exposed to N-methyl-D-aspartate (NMDA). The NMDA-induced excitotoxicity was quantified by densitometric measurements of propidium iodide (PI) uptake. THIP (100-1000 microM) was neuroprotective in slice cultures co-exposed to NMDA (10 microM) for 48 h......, while muscimol (100-1000 microM) and ATPA (1-3 microM) were without effect. The results demonstrate that direct GABA(A) agonism can mediate neuroprotection in the hippocampus in vitro as previously suggested in vivo....

  17. 3-Nitropropionic acid neurotoxicity in organotypic striatal and corticostriatal slice cultures is dependent on glucose and glutamate

    DEFF Research Database (Denmark)

    Storgaard, J; Kornblit, B T; Zimmer, J

    2000-01-01

    of lactate dehydrogenase in the medium and glutamic acid decarboxylase in tissue homogenates. 3-NPA toxicity (25-100 microM in 5 mM glucose, 24-48 h) appeared to be highly dependent on culture medium glucose levels. 3-NPA treatment caused also a dose-dependent lactate increase, reaching a maximum......Mitochondrial inhibition by 3-nitropropionic acid (3-NPA) causes striatal degeneration reminiscent of Huntington's disease. We studied 3-NPA neurotoxicity and possible indirect excitotoxicity in organotypic striatal and corticostriatal slice cultures. Neurotoxicity was quantified by assay...... of threefold increase above control at 100 microM. Both a high dose of glutamate (5 mM) and glutamate uptake blockade by dl-threo-beta-hydroxyaspartate potentiated 3-NPA neurotoxicity in corticostriatal slice cultures. Furthermore, striatum from corticostriatal cocultures was more sensitive to 3-NPA than...

  18. Element distribution of the barley plant grown in an agar slice suspended culture

    International Nuclear Information System (INIS)

    Makino-Nakanishi, Tomoko; Matsumoto, Satoshi

    1991-01-01

    An agar slice suspended culture was devised for the further study of the barley root. The roots were placed into an agar covered with a nylon cloth and suspended in a water culture vessel. Barley roots grown in the agar developed hardly any root hair. The element contents of the root grown in the agar culture and that in the water culture were measured by neutron activation analysis. The concentrations of K, Mg and Cl in the root grown in the agar were about half of these grown in the water. Na and Mn concentrations were the same and Ca concentration was slightly higher when grown in the agar. The agar system is expected to provide more information to study the root hair. (author)

  19. Protection of dichlorvos induced oxidative stress and nigrostriatal neuronal death by chronic Coenzyme Q10 pretreatment

    International Nuclear Information System (INIS)

    Binukumar, BK; Gupta, Nidhi; Bal, Amanjit; Gill, Kiran Dip

    2011-01-01

    Numerous epidemiological studies have shown an association between pesticide exposure and increased risk of developing Parkinson's diseases. Oxidative stress generated as a result of mitochondrial dysfunction has been implicated as an important factor in the etiology of Parkinson's disease. Previously, we reported that chronic dichlorvos exposure causes mitochondrial impairments and nigrostriatal neuronal death in rats. The present study was designed to test whether Coenzyme Q 10 (CoQ 10 ) administration has any neuroprotective effect against dichlorvos mediated nigrostriatal neuronal death, α-synuclein aggregation, and motor dysfunction. Male albino rats were administered dichlorvos by subcutaneous injection at a dose of 2.5 mg/kg body weight over a period of 12 weeks. Results obtained there after showed that dichlorvos exposure leads to enhanced mitochondrial ROS production, α-synuclein aggregation, decreased dopamine and its metabolite levels resulting in nigrostriatal neurodegeneration. Pretreatment by Coenzyme Q 10 (4.5 mg/kg ip for 12 weeks) to dichlorvos treated animals significantly attenuated the extent of nigrostriatal neuronal damage, in terms of decreased ROS production, increased dopamine and its metabolite levels, and restoration of motor dysfunction when compared to dichlorvos treated animals. Thus, the present study shows that Coenzyme Q 10 administration may attenuate dichlorvos induced nigrostriatal neurodegeneration, α-synuclein aggregation and motor dysfunction by virtue of its antioxidant action. - Highlights: → CoQ 10 administration attenuates dichlorvos induced nigrostriatal neurodegenaration. → CoQ 10 pre treatment leads to preservation of TH-IR neurons. → CoQ 10 may decrease oxidative damage and α-synuclin aggregation. → CoQ 10 treatment enhances motor function and protects rats from catalepsy.

  20. Excitatory amino acid neurotoxicity and modulation of glutamate receptor expression in organotypic brain slice cultures

    DEFF Research Database (Denmark)

    Zimmer, J; Kristensen, Bjarne Winther; Jakobsen, B

    2000-01-01

    Using organotypic slice cultures of hippocampus and cortex-striatum from newborn to 7 day old rats, we are currently studying the excitotoxic effects of kainic acid (KA), AMPA and NMDA and the neuroprotective effects of glutamate receptor blockers, like NBQX. For detection and quantitation...

  1. Culturing of PC12 Cells, Neuronal Cells, Astrocytes Cultures and Brain Slices in an Open Microfluidic System

    DEFF Research Database (Denmark)

    Al Atraktchi, Fatima Al-Zahraa; Bakmand, Tanya; Rømer Sørensen, Ane

    The brain is the center of the nervous system, where serious neurodegenerative diseases such as Parkinson’s, Alzheimer’s and Huntington’s are products of functional loss in the neural cells (1). Typical techniques used to investigate these diseases lack precise control of the cellular surroundings......, in addition to isolating the neural tissue from nutrient delivery and to creating unwanted gradients (2). This means that typical techniques used to investigate neurodegenerative diseases cannot mimic in vivo conditions, as closely as desired. We have developed a novel microfluidic system for culturing PC12...... cells, neuronal cells, astrocytes cultures and brain slices. The microfluidic system provides efficient nutrient delivery, waste removal, access to oxygen, fine control over the neurochemical environment and access to modern microscopy. Additionally, the setup consists of an in vitro culturing...

  2. Combined Stimulation with the Tumor Necrosis Factor α and the Epidermal Growth Factor Promotes the Proliferation of Hepatocytes in Rat Liver Cultured Slices

    Directory of Open Access Journals (Sweden)

    Francis Finot

    2012-01-01

    Full Text Available The culture liver slices are mainly used to investigate drug metabolism and xenobiotic-mediated liver injuries while apoptosis and proliferation remain unexplored in this culture model. Here, we show a transient increase in LDH release and caspase activities indicating an ischemic injury during the slicing procedure. Then, caspase activities decrease and remain low in cultured slices demonstrating a low level of apoptosis. The slicing procedure is also associated with the G0/G1 transition of hepatocytes demonstrated by the activation of stress and proliferation signalling pathways including the ERK1/2 and JNK1/2/3 MAPKinases and the transient upregulation of c-fos. The cells further progress up to mid-G1 phase as indicated by the sequential induction of c-myc and p53 mRNA levels after the slicing procedure and at 24 h of culture, respectively. The stimulation by epidermal growth factor induces the ERK1/2 phosphorylation but fails to activate expression of late G1 and S phase markers such as cyclin D1 and Cdk1 indicating that hepatocytes are arrested in mid-G1 phase of the cell cycle. However, we found that combined stimulation by the proinflammatory cytokine tumor necrosis factor α and the epidermal growth factor promotes the commitment to DNA replication as observed in vivo during the liver regeneration.

  3. PARP Inhibition Prevents Ethanol-Induced Neuroinflammatory Signaling and Neurodegeneration in Rat Adult-Age Brain Slice Cultures

    Science.gov (United States)

    Tajuddin, Nuzhath; Kim, Hee-Yong

    2018-01-01

    Using rat adult-age hippocampal-entorhinal cortical (HEC) slice cultures, we examined the role of poly [ADP-ribose] polymerase (PARP) in binge ethanol’s brain inflammatory and neurodegenerative mechanisms. Activated by DNA strand breaks, PARP (principally PARP1 in the brain) promotes DNA repair via poly [ADP-ribose] (PAR) products, but PARP overactivation triggers regulated neuronal necrosis (e.g., parthanatos). Previously, we found that brain PARP1 levels were upregulated by neurotoxic ethanol binges in adult rats and HEC slices, and PARP inhibitor PJ34 abrogated slice neurodegeneration. Binged HEC slices also exhibited increased Ca+2-dependent phospholipase A2 (PLA2) isoenzymes (cPLA2 IVA and sPLA2 IIA) that mobilize proinflammatory ω6 arachidonic acid (ARA). We now find in 4-day–binged HEC slice cultures (100 mM ethanol) that PARP1 elevations after two overnight binges precede PAR, cPLA2, and sPLA2 enhancements by 1 day and high-mobility group box-1 (HMGB1), an ethanol-responsive alarmin that augments proinflammatory cytokines via toll-like receptor-4 (TLR4), by 2 days. After verifying that PJ34 effectively blocks PARP activity (↑PAR), we demonstrated that, like PJ34, three other PARP inhibitors—olaparib, veliparib, and 4-aminobenzamide—provided neuroprotection from ethanol. Importantly, PJ34 and olaparib also prevented ethanol’s amplification of the PLA2 isoenzymes, and two PLA2 inhibitors were neuroprotective—thus coupling PARP to PLA2, with PLA2 activity promoting neurodegeneration. Also, PJ34 and olaparib blocked ethanol-induced HMGB1 elevations, linking brain PARP induction to TLR4 activation. The results provide evidence in adult brains that induction of PARP1 may mediate dual neuroinflammatory pathways (PLA2→phospholipid→ARA and HMGB1→TLR4→proinflammatory cytokines) that are complicit in binge ethanol-induced neurodegeneration. PMID:29339456

  4. Hyperexcitability and cell loss in kainate-treated hippocampal slice cultures

    DEFF Research Database (Denmark)

    Benedikz, Eirikur; Casaccia-Bonnefil, P; Stelzer, A

    1993-01-01

    Loss of hippocampal interneurons has been reported in patients with severe temporal lobe epilepsy and in animals treated with kainate. We investigated the relationship between KA induced epileptiform discharge and loss of interneurons in hippocampal slice cultures. Application of KA (1 micro......M) produced reversible epileptiform discharge without neurotoxicity. KA (5 microM), in contrast, produced irreversible epileptiform discharge and neurotoxicity, suggesting that the irreversible epileptiform discharge was required for the neuronal loss. Loss of CA3 pyramidal cells and parvalbumin......-like immunoreactive (PV-I) interneurons preceded loss of somatostatin-like immunoreactive (SS-I) interneurons suggesting a different time course of KA neurotoxicity in these subpopulations of interneurons....

  5. Role for excitatory amino acids in methamphetamine-induced nigrostriatal dopaminergic toxicity.

    Science.gov (United States)

    Sonsalla, P K; Nicklas, W J; Heikkila, R E

    1989-01-20

    The systemic administration of either methamphetamine or 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) to experimental animals produces degenerative changes in nigrostriatal dopaminergic neurons or their axon terminals. This study was conducted to determine if excitatory amino acids, which appear to be involved in various neurodegenerative disorders, might also contribute to the dopaminergic neurotoxicity produced in mice by either methamphetamine or MPTP. MK-801, phencyclidine, and ketamine, noncompetitive antagonists of one subtype of excitatory amino acid receptor, the N-methyl-D-aspartate receptor, provided substantial protection against neurotoxicity produced by methamphetamine but not that produced by MPTP. These findings indicate that excitatory amino acids play an important role in the nigrostriatal dopaminergic damage induced by methamphetamine.

  6. Glutamate receptor antagonists and growth factors modulate dentate granule cell neurogenesis in organotypic, rat hippocampal slice cultures

    DEFF Research Database (Denmark)

    Poulsen, Frantz Rom; Blaabjerg, Morten; Montero, Maria

    2005-01-01

    facing CA1 and the immediate subgranular zone, exposure for 3 days to the NMDA receptor blocking agents MK-801 (10 microM) or APV (25 microM) in the culture medium, increased the number of TOAD-64/Ulip/CRMP-4 (TUC-4)-positive cells as counted in the slice cultures at the end of the 3-day treatment period...

  7. Modelling glioblastoma tumour-host cell interactions using adult brain organotypic slice co-culture

    Directory of Open Access Journals (Sweden)

    Maria Angeles Marques-Torrejon

    2018-02-01

    Full Text Available Glioblastoma multiforme (GBM is an aggressive incurable brain cancer. The cells that fuel the growth of tumours resemble neural stem cells found in the developing and adult mammalian forebrain. These are referred to as glioma stem cells (GSCs. Similar to neural stem cells, GSCs exhibit a variety of phenotypic states: dormant, quiescent, proliferative and differentiating. How environmental cues within the brain influence these distinct states is not well understood. Laboratory models of GBM can be generated using either genetically engineered mouse models, or via intracranial transplantation of cultured tumour initiating cells (mouse or human. Unfortunately, these approaches are expensive, time-consuming, low-throughput and ill-suited for monitoring live cell behaviours. Here, we explored whole adult brain coronal organotypic slices as an alternative model. Mouse adult brain slices remain viable in a serum-free basal medium for several weeks. GSCs can be easily microinjected into specific anatomical sites ex vivo, and we demonstrate distinct responses of engrafted GSCs to diverse microenvironments in the brain tissue. Within the subependymal zone – one of the adult neural stem cell niches – injected tumour cells could effectively engraft and respond to endothelial niche signals. Tumour-transplanted slices were treated with the antimitotic drug temozolomide as proof of principle of the utility in modelling responses to existing treatments. Engraftment of mouse or human GSCs onto whole brain coronal organotypic brain slices therefore provides a simplified, yet flexible, experimental model. This will help to increase the precision and throughput of modelling GSC-host brain interactions and complements ongoing in vivo studies. This article has an associated First Person interview with the first author of the paper.

  8. Neuroprotective effects of the AMPA antagonist PNQX in oxygen-glucose deprivation in mouse hippocampal slice cultures and global cerebral ischemia in gerbils

    DEFF Research Database (Denmark)

    Montero, Maria; Nielsen, Marianne; Rønn, Lars Christian B

    2007-01-01

    PNQX (9-methyl-amino-6-nitro-hexahydro-benzo(F)quinoxalinedione) is a selective AMPA antagonist with demonstrated neuroprotective effects in focal ischemia in rats. Here we report corresponding effects in mouse hippocampal slice cultures subjected to oxygen and glucose deprivation (OGD) and in tr......PNQX (9-methyl-amino-6-nitro-hexahydro-benzo(F)quinoxalinedione) is a selective AMPA antagonist with demonstrated neuroprotective effects in focal ischemia in rats. Here we report corresponding effects in mouse hippocampal slice cultures subjected to oxygen and glucose deprivation (OGD......) and in transient global cerebral ischemia in gerbils. For in vitro studies, hippocampal slice cultures derived from 7-day-old mice and grown for 14 days, were submersed in oxygen-glucose deprived medium for 30 min and exposed to PNQX for 24 h, starting together with OGD, immediately after OGD, or 2 h after OGD...... stained for the neurodegeneration marker Fluoro-Jade B and immunostained for the astroglial marker glial fibrillary acidic protein revealed a significant PNQX-induced decrease in neuronal cell death and astroglial activation. We conclude that, PNQX provided neuroprotection against both global cerebral...

  9. Evaluation of the relative biological effectiveness of carbon ion beams in the cerebellum using the rat organotypic slice culture system

    International Nuclear Information System (INIS)

    Yoshida, Yukari; Katoh, Hiroyuki; Nakano, Takashi; Suzuki, Yoshiyuki; Al-Jahdari, Wael S.; Shirai, Katsuyuki; Hamada, Nobuyuki; Funayama, Tomoo; Sakashita, Tetsuya; Kobayashi, Yasuhiko

    2012-01-01

    The purpose of this study was to clarify the relative biological effectiveness (RBE) values of carbon ion (C) beams in normal brain tissues, a rat organotypic slice culture system was used. The cerebellum was dissected from 10-day-old Wistar rats, cut parasagittally into approximately 600-μm-thick slices and cultivated using a membrane-based culture system with a liquid-air interface. Slices were irradiated with 140 kV X-rays and 18.3 MeV/amu C-beams (linear energy transfer=108 keV/μm). After irradiation, the slices were evaluated histopathologically using hematoxylin and eosin staining, and apoptosis was quantified using the TdT-mediated dUTP-biotin nick-end labeling (TUNEL) assay. Disorganization of the external granule cell layer (EGL) and apoptosis of the external granule cells (EGCs) were induced within 24 h after exposure to doses of more than 5 Gy from C-beams and X-rays. In the early postnatal cerebellum, morphological changes following exposure to C-beams were similar to those following exposure to X-rays. The RBEs values of C-beams using the EGL disorganization and the EGC TUNEL index endpoints ranged from 1.4 to 1.5. This system represents a useful model for assaying the biological effects of radiation on the brain, especially physiological and time-dependent phenomena. (author)

  10. Behavioral, neurochemical, and electrophysiological changes in an early spontaneous mouse model of nigrostriatal degeneration.

    Science.gov (United States)

    Sgadò, Paola; Viaggi, Cristina; Pinna, Annalisa; Marrone, Cristina; Vaglini, Francesca; Pontis, Silvia; Mercuri, Nicola Biagio; Morelli, Micaela; Corsini, Giovanni Umberto

    2011-08-01

    In idiopathic Parkinson's disease, clinical symptoms do not emerge until consistent neurodegeneration has occurred. The late appearance of symptoms implies the existence of a relatively long preclinical period during which several disease-induced neurochemical changes take place to mask the existence of the disease and delay its clinical manifestations. The aim of this study was to examine the neurochemical, neurophysiological, and behavioral changes induced by the loss of nigrostriatal innervation in the En1+/-;En2-/- mouse, in the 10 months following degeneration, compared to En2 null mutant mice. Behavioral analysis (Pole-test, Beam-walking test, and Inverted grid test) and field potential recordings in the striatum indicated that loss of ~70% of nigrostriatal neurons produced no significant functional effects until 8 months of age, when En1+/-;En2-/- animals started to show frank motor deficits and electrophysiological alterations in corticostriatal plasticity. Similarly, alterations in dopamine homeostasis, dopamine turnover, and dopamine innervation were observed in aged animals compared to young En1+/-;En2-/- mice. These data suggests that in En1+/-;En2-/- mice nigrostriatal degeneration in the substantia nigra is functionally compensated.

  11. Sugar uptake and starch biosynthesis by slices of developing maize endosperm

    International Nuclear Information System (INIS)

    Felker, F.C.; Liu, Kangchien; Shannon, J.C.

    1990-01-01

    14 C-Sugar uptake and incorporation into starch by slices of developing maize (Zea mays L.) endosperm were examined and compared with sugar uptake by maize endosperm-derived suspension cultures. Rates of sucrose, fructose, and D- and L-glucose uptake by slices were similar, whereas uptake rates for these sugars differed greatly in suspension cultures. Concentration dependence of sucrose, fructose, and D-glucose uptake was biphasic (consisting of linear plus saturable components) with suspension cultures but linear with slices. These and other differences suggest that endosperm slices are freely permeable to sugars. After diffusion into the slices, sugars were metabolized and incorporated into starch. Starch synthesis, but not sugar accumulation, was greatly reduced by 2.5 millimolar p-chloromercuribenzenesulfonic acid and 0.1 millimolar carbonyl cyanide m-chlorophenylhydrazone. Starch synthesis was dependent on kernel age and incubation temperature, but not on external pH (5 through 8). Competing sugars generally did not affect the distribution of 14 C among the soluble sugars extracted from endosperm slices incubated in 14 C-sugars. Competing hexoses reduced the incorporation of 14 C into starch, but competing sucrose did not, suggesting that sucrose is not a necessary intermediate in starch biosynthesis. The bidirectional permeability of endosperm slices to sugars makes the characterization of sugar transport into endosperm slices impossible, however the model system is useful for experiments dealing with starch biosynthesis which occurs in the metabolically active tissue

  12. Tetrahydrobiopterin precursor sepiapterin provides protection against neurotoxicity of 1-methyl-4-phenylpyridinium in nigral slice cultures

    DEFF Research Database (Denmark)

    Madsen, Jakob Torp; Jansen, Pernille; Hesslinger, Christian

    2003-01-01

    Complex-I inhibition and oxidative processes have been implicated in the loss of nigral dopamine neurones in Parkinson's disease and the toxicity of MPTP and its metabolite MPP+. Tetrahydrobiopterin, an essential cofactor for tyrosine hydroxylase, may act as an antioxidant in dopaminergic neurones...... and protects against the toxic consequences of glutathione depletion. Here we studied the effects of manipulating tetrahydrobiopterin levels on MPP+ toxicity in organotypic, rat ventral mesencephalic slice cultures. In cultures exposed to 30 micro m MPP+ for 2 days, followed by 8 days 'recovery' in control...... medium, we measured dopamine and its metabolites in the tissue and culture medium by HPLC, lactate dehydrogenase release to the culture medium, cellular uptake of propidium iodide and counted the tyrosine hydroxylase-immunoreactive neurones. Inhibition of tetrahydrobiopterin synthesis by 2,4-diamino-6...

  13. Anatomical and electrophysiological changes in striatal TH interneurons after loss of the nigrostriatal dopaminergic pathway.

    Science.gov (United States)

    Ünal, Bengi; Shah, Fulva; Kothari, Janish; Tepper, James M

    2015-01-01

    Using transgenic mice that express enhanced green fluorescent protein (EGFP) under the control of the tyrosine hydroxylase (TH) promoter, we have previously shown that there are approximately 3,000 striatal EGFP-TH interneurons per hemisphere in mice. Here, we report that striatal TH-EGFP interneurons exhibit a small, transient but significant increase in number after unilateral destruction of the nigrostriatal dopaminergic pathway. The increase in cell number is accompanied by electrophysiological and morphological changes. The intrinsic electrophysiological properties of EGFP-TH interneurons ipsilateral to 6-OHDA lesion were similar to those originally reported in intact mice except for a significant reduction in the duration of a characteristic depolarization induced plateau potential. There was a significant change in the distribution of the four previously described electrophysiologically distinct subtypes of striatal TH interneurons. There was a concomitant increase in the frequency of both spontaneous excitatory and inhibitory post-synaptic currents, while their amplitudes did not change. Nigrostriatal lesions did not affect somatic size or dendritic length or branching, but resulted in an increase in the density of proximal dendritic spines and spine-like appendages in EGFP-TH interneurons. The changes indicate that electrophysiology properties and morphology of striatal EGFP-TH interneurons depend on endogenous levels of dopamine arising from the nigrostriatal pathway. Furthermore, these changes may serve to help compensate for the changes in activity of spiny projection neurons that occur following loss of the nigrostriatal innervation in experimental or in early idiopathic Parkinson's disease by increasing feedforward GABAergic inhibition exerted by these interneurons.

  14. Mesenchymal stem cells support neuronal fiber growth in an organotypic brain slice co-culture model.

    Science.gov (United States)

    Sygnecka, Katja; Heider, Andreas; Scherf, Nico; Alt, Rüdiger; Franke, Heike; Heine, Claudia

    2015-04-01

    Mesenchymal stem cells (MSCs) have been identified as promising candidates for neuroregenerative cell therapies. However, the impact of different isolation procedures on the functional and regenerative characteristics of MSC populations has not been studied thoroughly. To quantify these differences, we directly compared classically isolated bulk bone marrow-derived MSCs (bulk BM-MSCs) to the subpopulation Sca-1(+)Lin(-)CD45(-)-derived MSCs(-) (SL45-MSCs), isolated by fluorescence-activated cell sorting from bulk BM-cell suspensions. Both populations were analyzed with respect to functional readouts, that are, frequency of fibroblast colony forming units (CFU-f), general morphology, and expression of stem cell markers. The SL45-MSC population is characterized by greater morphological homogeneity, higher CFU-f frequency, and significantly increased nestin expression compared with bulk BM-MSCs. We further quantified the potential of both cell populations to enhance neuronal fiber growth, using an ex vivo model of organotypic brain slice co-cultures of the mesocortical dopaminergic projection system. The MSC populations were cultivated underneath the slice co-cultures without direct contact using a transwell system. After cultivation, the fiber density in the border region between the two brain slices was quantified. While both populations significantly enhanced fiber outgrowth as compared with controls, purified SL45-MSCs stimulated fiber growth to a larger degree. Subsequently, we analyzed the expression of different growth factors in both cell populations. The results show a significantly higher expression of brain-derived neurotrophic factor (BDNF) and basic fibroblast growth factor in the SL45-MSCs population. Altogether, we conclude that MSC preparations enriched for primary MSCs promote neuronal regeneration and axonal regrowth, more effectively than bulk BM-MSCs, an effect that may be mediated by a higher BDNF secretion.

  15. Functional Stem Cell Integration into Neural Networks Assessed by Organotypic Slice Cultures.

    Science.gov (United States)

    Forsberg, David; Thonabulsombat, Charoensri; Jäderstad, Johan; Jäderstad, Linda Maria; Olivius, Petri; Herlenius, Eric

    2017-08-14

    Re-formation or preservation of functional, electrically active neural networks has been proffered as one of the goals of stem cell-mediated neural therapeutics. A primary issue for a cell therapy approach is the formation of functional contacts between the implanted cells and the host tissue. Therefore, it is of fundamental interest to establish protocols that allow us to delineate a detailed time course of grafted stem cell survival, migration, differentiation, integration, and functional interaction with the host. One option for in vitro studies is to examine the integration of exogenous stem cells into an existing active neural network in ex vivo organotypic cultures. Organotypic cultures leave the structural integrity essentially intact while still allowing the microenvironment to be carefully controlled. This allows detailed studies over time of cellular responses and cell-cell interactions, which are not readily performed in vivo. This unit describes procedures for using organotypic slice cultures as ex vivo model systems for studying neural stem cell and embryonic stem cell engraftment and communication with CNS host tissue. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  16. Stability of cytochromes P450 and phase II conjugation systems in precision-cut rat lung slices cultured up to 72 h.

    Science.gov (United States)

    Umachandran, Meera; Ioannides, Costas

    2006-07-05

    The objective of the present study was to evaluate the stability of cytochrome P450 enzymes and of the conjugation enzyme systems epoxide hydrolase, glucuronosyl transferase, sulphotransferase and glutathione S-transferase in precision-cut rat lung slices incubated in RPMI media for different time periods up to 72 h. Moreover, the effect of culturing of lung slices on total glutathione levels and glutathione reductase was also investigated. Monitoring of cytochrome P450 activity was achieved using established diagnostic probes, but when activity in the lung was low the maintenance of the various enzymes in culture was determined immunologically using Western blotting. The dealkylation of pentoxyresorufin declined markedly during the first 4h of incubation but in the case of ethoxyresorufin loss of activity was more gradual and less severe. Western blot analysis revealed that the rate of decrease in cytochrome P450 apoprotein levels was isoform-specific with CYP2E1 being the most stable and CYP3A the least stable. Generally, phase II activities, especially cytosolic sulphotransferase, were relatively more stable throughout the incubation period compared with cytochromes P450. Finally, glutathione reductase activity and total glutathione levels were maintained throughout the 72 h incubation. The present studies indicate that xenobiotic-metabolising enzymes in precision-cut rat lung slices decline in culture, but the rate of loss differs and depends on the nature of the enzyme.

  17. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  18. The Nigrostriatal Dopamine System and Methamphetamine: Roles for Excitoxicity and Environmental, Metabolic and Oxidative Stress

    National Research Council Canada - National Science Library

    Yamamoto, Bryan

    2002-01-01

    .... Similarly, the psychostimulant drug, methamphetamine also produces relatively selective damage to nigrostriatal dopamine neurons and is a widespread problem and drug of abuse throughout the U.S...

  19. The Nigrostriatal Dopamine System and Methamphetamine: Roles for Excitotoxicity and Environmental, Metabolic and Oxidative Stress

    National Research Council Canada - National Science Library

    Yamamoto, Bryan

    2005-01-01

    .... Similarly, the psychostimulant drug, methamphetamine also produces relatively selective damage to nigrostriatal dopamine neurons and is a widespread problem and drug of abuse throughout the U.S...

  20. Trafficking of astrocytic vesicles in hippocampal slices

    International Nuclear Information System (INIS)

    Potokar, Maja; Kreft, Marko; Lee, So-Young; Takano, Hajime; Haydon, Philip G.; Zorec, Robert

    2009-01-01

    The increasingly appreciated role of astrocytes in neurophysiology dictates a thorough understanding of the mechanisms underlying the communication between astrocytes and neurons. In particular, the uptake and release of signaling substances into/from astrocytes is considered as crucial. The release of different gliotransmitters involves regulated exocytosis, consisting of the fusion between the vesicle and the plasma membranes. After fusion with the plasma membrane vesicles may be retrieved into the cytoplasm and may continue to recycle. To study the mobility implicated in the retrieval of secretory vesicles, these structures have been previously efficiently and specifically labeled in cultured astrocytes, by exposing live cells to primary and secondary antibodies. Since the vesicle labeling and the vesicle mobility properties may be an artifact of cell culture conditions, we here asked whether the retrieving exocytotic vesicles can be labeled in brain tissue slices and whether their mobility differs to that observed in cell cultures. We labeled astrocytic vesicles and recorded their mobility with two-photon microscopy in hippocampal slices from transgenic mice with fluorescently tagged astrocytes (GFP mice) and in wild-type mice with astrocytes labeled by Fluo4 fluorescence indicator. Glutamatergic vesicles and peptidergic granules were labeled by the anti-vesicular glutamate transporter 1 (vGlut1) and anti-atrial natriuretic peptide (ANP) antibodies, respectively. We report that the vesicle mobility parameters (velocity, maximal displacement and track length) recorded in astrocytes from tissue slices are similar to those reported previously in cultured astrocytes.

  1. The Nigrostriatal Dopamine System and Methamphetamine: Roles for Excitotoxicity and Environment, Metabolic and Oxidative Stress

    National Research Council Canada - National Science Library

    Yamamoto, Bryan

    2001-01-01

    .... Similarly, the psychostimulant drug, methamphetamine also produces relatively selective damage to nigrostriatal dopamine neurons and is rapidly becoming a widespread problem and drug of abuse throughout the U.S...

  2. Acrolein acts as a neurotoxin in the nigrostriatal dopaminergic system of rat: involvement of ?-synuclein aggregation and programmed cell death

    OpenAIRE

    Wang, Yi-Ting; Lin, Hui-Ching; Zhao, Wei-Zhong; Huang, Hui-Ju; Lo, Yu-Li; Wang, Hsiang-Tsui; Maan-Yuh Lin, Anya

    2017-01-01

    Clinical studies report significant increases in acrolein (an ?,?-unsaturated aldehyde) in the substantia nigra (SN) of patients with Parkinson?s disease (PD). In the present study, acrolein-induced neurotoxicity in the nigrostriatal dopaminergic system was investigated by local infusion of acrolein (15, 50, 150?nmoles/0.5??l) in the SN of Sprague-Dawley rats. Acrolein-induced neurodegeneration of nigrostriatal dopaminergic system was delineated by reductions in tyrosine hydroxylase (TH) leve...

  3. The Nigrostriatal Dopamine System and Methamphetamine: Roles for Excitotoxicity and Environment, Metabolic and Oxidative Stress

    National Research Council Canada - National Science Library

    Yamamoto, Bryan

    2000-01-01

    .... Similarly, the psycho stimulant drug, methamphetamine also produces relatively selective damage to nigrostriatal dopamine neurons and is rapidly becoming a widespread problem and drug of abuse throughout the U.S...

  4. Attenuation of methamphetamine-induced nigrostriatal dopaminergic neurotoxicity in mice by lipopolysaccharide pretreatment.

    Science.gov (United States)

    Lin, Yin Chiu; Kuo, Yu-Min; Liao, Pao-Chi; Cherng, Chianfang G; Su, Su-Wen; Yu, Lung

    2007-04-30

    Immunological activation has been proposed to play a role in methamphetamine-induced dopaminergic terminal damage. In this study, we examined the roles of lipopolysaccharide, a pro-inflammatory and inflammatory factor, treatment in modulating the methamphetamine-induced nigrostriatal dopamine neurotoxicity. Lipopolysaccharide pretreatment did not affect the basal body temperature or methamphetamine-elicited hyperthermia three days later. Such systemic lipopolysaccharide treatment mitigated methamphetamine-induced striatal dopamine and 3,4-dihydroxyphenylacetic acid depletions in a dose-dependent manner. As the most potent dose (1 mg/kg) of lipopolysaccharide was administered two weeks, one day before or after the methamphetamine dosing regimen, methamphetamine-induced striatal dopamine and 3,4-dihydroxyphenylacetic acid depletions remained unaltered. Moreover, systemic lipopolysaccharide pretreatment (1 mg/kg) attenuated local methamphetamine infusion-produced dopamine and 3,4-dihydroxyphenylacetic acid depletions in the striatum, indicating that the protective effect of lipopolysaccharide is less likely due to interrupted peripheral distribution or metabolism of methamphetamine. We concluded a critical time window for systemic lipopolysaccharide pretreatment in exerting effective protection against methamphetamine-induced nigrostriatal dopamine neurotoxicity.

  5. Three-dimensional electrode array for brain slice culture

    DEFF Research Database (Denmark)

    Vazquez Rodriguez, Patricia

    Multielektroder arrays (MEA) er rækker af elektroder mest i mikrometer størrelse, som er blevet brugt i stor omfang til at stimulere og måle elektrisk aktivitet fra neuronale netværker. Brug af disse for at analysere hjerne slices (hjerneskiver) kan give indsigt i interaktioner mellem neuroner, e...

  6. Protective effect of resveratrol against nigrostriatal pathway injury in striatum via JNK pathway.

    Science.gov (United States)

    Li, Dan; Liu, Nan; Zhao, Liang; Tong, Lei; Kawano, Hitoshi; Yan, Hong-Jing; Li, Hong-Peng

    2017-01-01

    Nigrostriatal pathway injury is one of the traumatic brain injury models that usually lead to neurological dysfunction or neuron necrosis. Resveratrol-induced benefits have recently been demonstrated in several models of neuronal degeneration diseases. However, the protective properties of resveratrol against neurodegeneration have not been explored definitely. Thus, we employ the nigrostriatal pathway injury model to mimic the insults on the brain. Resveratrol decreased the p-ERK expression and increased the p-JNK expression compared to the DMSO group, but not alter the p38 MAPK proteins around the lesion site by Western blot. Prior to the injury, mice were infused with resveratrol intracerebroventricularly with or without JNK-IN-8, a specific c-JNK pathway inhibitor for JNK1, JNK2 and JNK4. The study assessed modified improved neurological function score (mNSS) and beam/walking test, the level of inflammatory cytokines IL-1β, IL-6 and TNF-α, and striatal expression of Bax and Bcl-2 proteins associated with neuronal apoptosis. The results revealed that resveratrol exerted a neuroprotective effect as shown by the improved mNSS and beam latency, anti-inflammatory effects as indicated by the decreased level of IL-1β, TNF-α and IL-6. Furthermore, resveratrol up-regulated the protein expression of p-JNK and Bcl-2, down-regulated the expression of Bax and the number of Fluoro-Jade C (FJC) positive neurons. However, these advantages of resveratrol were abolished by JNK-IN-8 treatment. Overall, we demonstrated that resveratrol treatment attenuates the nigrostriatal pathway injury-induced neuronal apoptosis and inflammation via activation of c-JNK signaling. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. sigma receptor ligands attenuate N-methyl-D-aspartate cytotoxicity in dopaminergic neurons of mesencephalic slice cultures.

    Science.gov (United States)

    Shimazu, S; Katsuki, H; Takenaka, C; Tomita, M; Kume, T; Kaneko, S; Akaike, A

    2000-01-28

    We investigated the potential neuroprotective effects of several sigma receptor ligands in organotypic midbrain slice cultures as an excitotoxicity model system. When challenged with 100-microM N-methyl-D-aspartate (NMDA) for 24 h, dopaminergic neurons in midbrain slice cultures degenerated, and this was prevented by (5R, 10S)-(+)-5-methyl-10,11-dihydro-5H-dibenzo[a,b]-cyclohepten-5, 10-imine (MK-801; 1-10 microM). Concomitant application of ifenprodil (1-10 microM) or haloperidol (1-10 microM), both of which are high-affinity sigma receptor ligands, significantly attenuated the neurotoxicity of 100 microM NMDA. The sigma(1) receptor-selective ligand (+)-N-allylnormetazocine ((+)-SKF 10047; 1-10 microM) was also effective in attenuating the toxicity of NMDA. The effect of R(-)-N-(3-phenyl-1-propyl)-1-phenyl-2-aminopropane hydrochloride ((-)-PPAP), a sigma receptor ligand with negligible affinity for the phencyclidine site of NMDA receptors, was also examined. (-)-PPAP (3-100 microM) caused a concentration-dependent reduction of NMDA cytotoxicity, with significant protection at concentrations of 30 and 100 microM. In contrast, (+)-SKF 10047 (10 microM) and (-)-PPAP (100 microM) showed no protective effects against cell death induced by the Ca(2+) ionophore ionomycin (1-3 microM). These results indicate that sigma receptor ligands attenuate the cytotoxic effects of NMDA on midbrain dopaminergic neurons, possibly via inhibition of NMDA receptor functions.

  8. ELECTROPHYSIOLOGICAL CHARACTERIZATION OF DOPAMINERGIC AND NONDOPAMINERGIC NEURONS IN ORGANOTYPIC SLICE CULTURES OF THE RAT VENTRAL MESENCEPHALON

    DEFF Research Database (Denmark)

    STEENSEN, BH; NEDERGAARD, S; OSTERGAARD, K

    1995-01-01

    -old organotypic slice cultures of the ventral mesencephalon prepared from newborn rats. Dopaminergic neurones were distinguished from non-dopaminergic neurones by staining with the autofluorescent serotonin analogue 5,7-dihydroxytryptamine and briefly viewing the preparation with short exposures to ultraviolet...... 81 M Omega), were silent or fired spontaneously at a low frequency (0-9 Hz), and no spontaneous GABA(A)-ergic inhibitory postsynaptic potentials or inward rectification were present. In contrast, non-dopaminergic neurones had fast action potentials (0.6-3.2 ms), low input resistance (mean 32 M Omega...

  9. Conversion of Synthetic Aβ to In Vivo Active Seeds and Amyloid Plaque Formation in a Hippocampal Slice Culture Model.

    Science.gov (United States)

    Novotny, Renata; Langer, Franziska; Mahler, Jasmin; Skodras, Angelos; Vlachos, Andreas; Wegenast-Braun, Bettina M; Kaeser, Stephan A; Neher, Jonas J; Eisele, Yvonne S; Pietrowski, Marie J; Nilsson, K Peter R; Deller, Thomas; Staufenbiel, Matthias; Heimrich, Bernd; Jucker, Mathias

    2016-05-04

    The aggregation of amyloid-β peptide (Aβ) in brain is an early event and hallmark of Alzheimer's disease (AD). We combined the advantages of in vitro and in vivo approaches to study cerebral β-amyloidosis by establishing a long-term hippocampal slice culture (HSC) model. While no Aβ deposition was noted in untreated HSCs of postnatal Aβ precursor protein transgenic (APP tg) mice, Aβ deposition emerged in HSCs when cultures were treated once with brain extract from aged APP tg mice and the culture medium was continuously supplemented with synthetic Aβ. Seeded Aβ deposition was also observed under the same conditions in HSCs derived from wild-type or App-null mice but in no comparable way when HSCs were fixed before cultivation. Both the nature of the brain extract and the synthetic Aβ species determined the conformational characteristics of HSC Aβ deposition. HSC Aβ deposits induced a microglia response, spine loss, and neuritic dystrophy but no obvious neuron loss. Remarkably, in contrast to in vitro aggregated synthetic Aβ, homogenates of Aβ deposits containing HSCs induced cerebral β-amyloidosis upon intracerebral inoculation into young APP tg mice. Our results demonstrate that a living cellular environment promotes the seeded conversion of synthetic Aβ into a potent in vivo seeding-active form. In this study, we report the seeded induction of Aβ aggregation and deposition in long-term hippocampal slice cultures. Remarkably, we find that the biological activities of the largely synthetic Aβ aggregates in the culture are very similar to those observed in vivo This observation is the first to show that potent in vivo seeding-active Aβ aggregates can be obtained by seeded conversion of synthetic Aβ in a living (wild-type) cellular environment. Copyright © 2016 the authors 0270-6474/16/365084-10$15.00/0.

  10. The Small GTP-Binding Protein Rhes Influences Nigrostriatal-Dependent Motor Behavior During Aging.

    Science.gov (United States)

    Pinna, Annalisa; Napolitano, Francesco; Pelosi, Barbara; Di Maio, Anna; Wardas, Jadwiga; Casu, Maria Antonietta; Costa, Giulia; Migliarini, Sara; Calabresi, Paolo; Pasqualetti, Massimo; Morelli, Micaela; Usiello, Alessandro

    2016-04-01

    Here we aimed to evaluate: (1) Rhes mRNA expression in mouse midbrain, (2) the effect of Rhes deletion on the number of dopamine neurons, (3) nigrostriatal-sensitive behavior during aging in knockout mice. Radioactive in situ hybridization was assessed in adult mice. The beam-walking test was executed in 3-, 6- and 12-month-old mice. Immunohistochemistry of midbrain tyrosine hydroxylase (TH)-positive neurons was performed in 6- and 12-month-old mice. Rhes mRNA is expressed in TH-positive neurons of SNpc and the ventral tegmental area. Moreover, lack of Rhes leads to roughly a 20% loss of nigral TH-positive neurons in both 6- and 12-month-old mutants, when compared with their age-matched controls. Finally, lack of Rhes triggers subtle alterations in motor performance and coordination during aging. Our findings indicate a fine-tuning role of Rhes in regulating the number of TH-positive neurons of the substantia nigra and nigrostriatal-sensitive motor behavior during aging. © 2016 International Parkinson and Movement Disorder Society.

  11. Testosterone induces molecular changes in dopamine signaling pathway molecules in the adolescent male rat nigrostriatal pathway.

    Directory of Open Access Journals (Sweden)

    Tertia D Purves-Tyson

    Full Text Available Adolescent males have an increased risk of developing schizophrenia, implicating testosterone in the precipitation of dopamine-related psychopathology. Evidence from adult rodent brain indicates that testosterone can modulate nigrostriatal dopamine. However, studies are required to understand the role testosterone plays in maturation of dopamine pathways during adolescence and to elucidate the molecular mechanism(s by which testosterone exerts its effects. We hypothesized that molecular indices of dopamine neurotransmission [synthesis (tyrosine hydroxylase, breakdown (catechol-O-methyl transferase; monoamine oxygenase, transport [vesicular monoamine transporter (VMAT, dopamine transporter (DAT] and receptors (DRD1-D5] would be changed by testosterone or its metabolites, dihydrotestosterone and 17β-estradiol, in the nigrostriatal pathway of adolescent male rats. We found that testosterone and dihydrotestosterone increased DAT and VMAT mRNAs in the substantia nigra and that testosterone increased DAT protein at the region of the cell bodies, but not in target regions in the striatum. Dopamine receptor D2 mRNA was increased and D3 mRNA was decreased in substantia nigra and/or striatum by androgens. These data suggest that increased testosterone at adolescence may change dopamine responsivity of the nigrostriatal pathway by modulating, at a molecular level, the capacity of neurons to transport and respond to dopamine. Further, dopamine turnover was increased in the dorsal striatum following gonadectomy and this was prevented by testosterone replacement. Gene expression changes in the dopaminergic cell body region may serve to modulate both dendritic dopamine feedback inhibition and reuptake in the dopaminergic somatodendritic field as well as dopamine release and re-uptake dynamics at the presynaptic terminals in the striatum. These testosterone-induced changes of molecular indices of dopamine neurotransmission in males are primarily androgen

  12. Comparison of neuroprotective effects of erythropoietin (EPO) and carbamylerythropoietin (CEPO) against ischemia-like oxygen-glucose deprivation (OGD) and NMDA excitotoxicity in mouse hippocampal slice cultures

    DEFF Research Database (Denmark)

    Montero, Maria; Rom Poulsen, Frantz; Noraberg, Jens

    2007-01-01

    of hematopoietic bioactivity, is the chemically modified, EPO-derivative carbamylerythropoietin (CEPO). For comparison of the neuroprotective effects of CEPO and EPO, we subjected organotypic hippocampal slice cultures to oxygen-glucose deprivation (OGD) or N-methyl-d-aspartate (NMDA) excitotoxicity. Hippocampal...... slice cultures were pretreated for 24 h with 100 IU/ml EPO (=26 nM) or 26 nM CEPO before OGD or NMDA lesioning. Exposure to EPO and CEPO continued during OGD and for the next 24 h until histology, as well as during the 24 h exposure to NMDA. Neuronal cell death was quantified by cellular uptake...... of propidium iodide (PI), recorded before the start of OGD and NMDA exposure and 24 h after. In cultures exposed to OGD or NMDA, CEPO reduced PI uptake by 49+/-3 or 35+/-8%, respectively, compared to lesion-only controls. EPO reduced PI uptake by 33+/-5 and 15+/-8%, respectively, in the OGD and NMDA exposed...

  13. The nigrostriatal dopamine system of aging GFRα-1 heterozygous mice: neurochemistry, morphology and behavior

    Science.gov (United States)

    Zaman, Vandana; Boger, Heather A.; Granholm, Ann-Charlotte; Rohrer, Baerbel; Moore, Alfred; Buhusi, Mona; Gerhardt, Greg A.; Hoffer, Barry J.; Middaugh, Lawrence D.

    2009-01-01

    Given the established importance of glial cell line-derived neurotrophic factor (GDNF) in maintaining dopaminergic neurotransmitter systems, the nigrostriatal system and associated behaviors of mice with genetic reduction of its high-affinity receptor, GDNF receptor (GFR)α-1 (GFRα-1+/−), were compared with wild-type controls. Motor activity and the stimulatory effects of a dopamine (DA) D1 receptor agonist (SKF 82958) were assessed longitudinally at 8 and 18 months of age. Monoamine concentrations and dopaminergic nerve terminals in the striatum and the number of dopaminergic neurons in the substantia nigra (SN) were assessed. The results support the importance of GFRα-1 in maintaining normal function of the nigrostriatal dopaminergic system, with deficits being observed for GFRα-1+/− mice at both ages. Motor activity was lower and the stimulatory effects of the DA agonist were enhanced for the older GFRα-1+/− mice. DA in the striatum was reduced in the GFRα-1+/− mice at both ages, and tyrosine hydroxylase-positive cell numbers in the SN were reduced most substantially in the older GFRα-1+/− mice. The combined behavioral, pharmacological probe, neurochemical and morphological measures provide evidence of abnormalities in GFRα-1+/− mice that are indicative of an exacerbated aging-related decline in dopaminergic system function. The noted deficiencies, in turn, suggest that GFRα-1 is necessary for GDNF to maintain normal function of the nigrostriatal dopaminergic system. Although the precise mechanism(s) for the aging-related changes in the dopaminergic system remain to be established, the present study clearly establishes that genetic reductions in GFRα-1 can contribute to the degenerative changes observed in this system during the aging process. PMID:18973577

  14. Slice cultures of the imprinting-relevant forebrain area MNH of the domestic chick: quantitative characterization of neuronal morphology.

    Science.gov (United States)

    Hofmann, H; Braun, K

    1995-05-26

    The persistence of morphological features of neurons in slice cultures of the imprinting-relevant forebrain area MNH (mediorostral neostriatum and hyperstriatum ventrale) of the domestic chick was analysed at 7, 14, 21 and 28 days in vitro. After having been explanted and kept in culture the neurons in vitro have larger soma areas, longer and more extensively branched dendritic trees and lower spine frequencies compared to the neurons in vivo. During the analyzed culturing period, the parameters soma area, total and mean dendritic length, number of dendrites, number of dendritic nodes per dendrite and per neuron as well as the spine densities in different dendritic segments showed no significant differences between early and late periods. Highly correlated in every age group were the total dendritic length and the number of dendritic nodes per neuron, indicating regular ramification during dendritic growth. Since these morphological parameters remain stable during the first 4 weeks in vitro, this culture system may provide a suitable model to investigate experimentally induced morphological changes.

  15. Oxygen Glucose Deprivation in Rat Hippocampal Slice Cultures Results in Alterations in Carnitine Homeostasis and Mitochondrial Dysfunction

    Science.gov (United States)

    Rau, Thomas F.; Lu, Qing; Sharma, Shruti; Sun, Xutong; Leary, Gregory; Beckman, Matthew L.; Hou, Yali; Wainwright, Mark S.; Kavanaugh, Michael; Poulsen, David J.; Black, Stephen M.

    2012-01-01

    Mitochondrial dysfunction characterized by depolarization of mitochondrial membranes and the initiation of mitochondrial-mediated apoptosis are pathological responses to hypoxia-ischemia (HI) in the neonatal brain. Carnitine metabolism directly supports mitochondrial metabolism by shuttling long chain fatty acids across the inner mitochondrial membrane for beta-oxidation. Our previous studies have shown that HI disrupts carnitine homeostasis in neonatal rats and that L-carnitine can be neuroprotective. Thus, this study was undertaken to elucidate the molecular mechanisms by which HI alters carnitine metabolism and to begin to elucidate the mechanism underlying the neuroprotective effect of L-carnitine (LCAR) supplementation. Utilizing neonatal rat hippocampal slice cultures we found that oxygen glucose deprivation (OGD) decreased the levels of free carnitines (FC) and increased the acylcarnitine (AC): FC ratio. These changes in carnitine homeostasis correlated with decreases in the protein levels of carnitine palmitoyl transferase (CPT) 1 and 2. LCAR supplementation prevented the decrease in CPT1 and CPT2, enhanced both FC and the AC∶FC ratio and increased slice culture metabolic viability, the mitochondrial membrane potential prior to OGD and prevented the subsequent loss of neurons during later stages of reperfusion through a reduction in apoptotic cell death. Finally, we found that LCAR supplementation preserved the structural integrity and synaptic transmission within the hippocampus after OGD. Thus, we conclude that LCAR supplementation preserves the key enzymes responsible for maintaining carnitine homeostasis and preserves both cell viability and synaptic transmission after OGD. PMID:22984394

  16. Lysosome stabilization in slices of rat liver when incubated with vitamin A excess

    International Nuclear Information System (INIS)

    Morre, D.M.; Morre, D.J.; Bowen, S.; Reutter, W.

    1986-01-01

    An organ culture of slices of livers from adult rats was used to study effect of vitamin A (all-trans retinol) on lysosome stability. Lysosomes were purified by centrifugation in Percoll gradients. Preparations were monitored by electron microscopy and evaluated by morphometry and assays of marker enzymes. Enrichments relative to homogenates and crude pellets were estimated from latent (triton X-100) acid p-nitrophenylphosphatase specific activities. Lysosomes prepared from unincubated slices were enriched 50-fold in latent acid phosphatase relative to homogenates. In contrast, lysosomes prepared from slices incubated for 30 min in PBS alone were enriched only 20-fold. When 25 μg/ml retinol was included in the incubation medium, enrichments of 40-fold were obtained. The integrity of the slices was monitored by electron microscopy and their viability was confirmed by a sustained uptake and incorporation of [ 3 H]leucine into protein (up to 2 h in culture). The loss of lysosomes from homogenates of slices incubated in the absence of retinol was accompanied by a loss of acid phosphatase from the lysosomal pellet to the supernatant during purification. Addition of retinol to slices just prior to homogenization was without effect. The results demonstrate a stabilizing influence of vitamin A on lysosomes during incubation of licer slices. The findings contrast earlier reports of retinol-induced lysosome fragility in other in vitro systems

  17. 123-I ioflupane (Datscan) presynaptic nigrostriatal imaging in patients with movement disorders

    International Nuclear Information System (INIS)

    Soriano Castrejon, Angel; Garcia Vicente, Ana Maria; Cortes Romera, Montserrat; Rodado Marina, Sonia; Poblete Garcia, Victor Manuel; Ruiz Solis, Sebastian Ruiz; Talavera Rubio, Maria del Prado; Vaamonde Cano, Julia

    2005-01-01

    123-I Ioflupane (Datscan) presynaptic imaging has been shown to have a significant utility in the assessment of patients with movement disorders 123 I Ioflupane SPECT is able to distinguish between Parkinson's disease (PD) and other forms of parkinsonism without degeneration of the nigrostriatal pathway, including a common movement disorder such as essential tremor, and to assess disease progression in PD and other neuro degenerative disorders involving the substantia nigra. (author)

  18. Adaptation of Microplate-based Respirometry for Hippocampal Slices and Analysis of Respiratory Capacity

    Science.gov (United States)

    Schuh, Rosemary A.; Clerc, Pascaline; Hwang, Hyehyun; Mehrabian, Zara; Bittman, Kevin; Chen, Hegang; Polster, Brian M.

    2011-01-01

    Multiple neurodegenerative disorders are associated with altered mitochondrial bioenergetics. Although mitochondrial O2 consumption is frequently measured in isolated mitochondria, isolated synaptic nerve terminals (synaptosomes), or cultured cells, the absence of mature brain circuitry is a remaining limitation. Here we describe the development of a method that adapts the Seahorse Extracellular Flux Analyzer (XF24) for the microplate-based measurement of hippocampal slice O2 consumption. As a first evaluation of the technique, we compared whole slice bioenergetics to previous measurements made with synaptosomes or cultured neurons. We found that mitochondrial respiratory capacity and O2 consumption coupled to ATP synthesis could be estimated in cultured or acute hippocampal slices with preserved neural architecture. Mouse organotypic hippocampal slices oxidizing glucose displayed mitochondrial O2 consumption that was well-coupled, as determined by the sensitivity to the ATP synthase inhibitor oligomycin. However stimulation of respiration by uncoupler was modest (<120% of basal respiration) compared to previous measurements in cells or synaptosomes, although enhanced slightly (to ~150% of basal respiration) by the acute addition of the mitochondrial complex I-linked substrate pyruvate. These findings suggest a high basal utilization of respiratory capacity in slices and a limitation of glucose-derived substrate for maximal respiration. The improved throughput of microplate-based hippocampal respirometry over traditional O2 electrode-based methods is conducive to neuroprotective drug screening. When coupled with cell type-specific pharmacology or genetic manipulations, the ability to efficiently measure O2 consumption from whole slices should advance our understanding of mitochondrial roles in physiology and neuropathology. PMID:21520220

  19. Dopamine release in organotypic cultures of foetal mouse mesencephalon: effects of depolarizing agents, pargyline, nomifensine, tetrodotoxin and calcium

    DEFF Research Database (Denmark)

    Larsen, Trine R; Rossen, Sine; Gramsbergen, Jan B

    2008-01-01

    Organotypic mesencephalic cultures provide an attractive in vitro alternative to study development of the nigrostriatal system and pathophysiological mechanisms related to Parkinson's disease. However, dopamine (DA) release mechanisms have been poorly characterized in such cultures. We report her...

  20. Local establishment of repetitive long-term potentiation-induced synaptic enhancement in cultured hippocampal slices with divided input pathways.

    Science.gov (United States)

    Oe, Yuki; Tominaga-Yoshino, Keiko; Ogura, Akihiko

    2011-09-01

    Long-term potentiation (LTP) in the rodent hippocampus is a popular model for synaptic plasticity, which is considered the cellular basis for brain memory. Because most LTP analysis involves acutely prepared brain slices, however, the longevity of single LTP has not been well documented. Using stable hippocampal slice cultures for long-term examination, we previously found that single LTP disappeared within 1 day. In contrast, repeated induction of LTP led to the development of a distinct type of plasticity that lasted for more than 3 weeks and was accompanied by the formation of new synapses. Naming this novel plastic phenomenon repetitive LTP-induced synaptic enhancement (RISE), we proposed it as a model for the cellular processes involved in long-term memory formation. However, because in those experiments LTP was induced pharmacologically in the whole slice, it is not known whether RISE has input-pathway specificity, an essential property for memory. In this study, we divided the input pathway of CA1 pyramidal neurons by a knife cut and induced LTP three times, the third by tetanic stimulation in one of the divided pathways to express RISE specifically. Voltage-sensitive dye imaging and Golgi-staining performed 2 weeks after the three LTP inductions revealed both enhanced synaptic strength and increased dendritic spine density confined to the tetanized region. These results demonstrate that RISE is a feasible cellular model for long-term memory. Copyright © 2011 Wiley-Liss, Inc.

  1. Measurement of slice sensitivity profile for a 64-slice spiral CT system

    International Nuclear Information System (INIS)

    Liu Chuanya; Qin Weichang; Wang Wei; Lu Chuanyou

    2006-01-01

    Objective: To measure and evaluate slice sensitivity profile (SSP) and the full width at half-maximum(FWHM) for a 64-slice spiral CT system. Methods: Using the same CT technique and body mode as those used for clinical CT, delta phantom was scanned with Somatom Sensation 64-slice spiral CT. SSPs and FWHM were measured both with reconstruction slice width of 0.6 mm at pitch=0.50, 0.75, 1.00, 1.25, 1.50 and with reconstruction slice width of 0.6, 1.0, 1.5 mm at pitch=1 respectively. Results: For normal slice width of 0. 6 mm, the measured FWHM, i.e. effective slice width, is 0.67, 0.67, 0.66, 0.69, 0.69 mm at different pitch. All the measured FWHM deviate less than 0.1 mm from the nominal slice width. The measured SSPs are symmetrical, bell-shaped curves without far-reaching tails, and show only slight variations as a function of the spiral pitch. When reconstruction slice width increase, relative SSP become wider. Conclusions: The variation of pitch hardly has effect all on SSP, effective slice width, and z-direction spatial resolution for Sensation 64-slice spiral CT system, which is helpful to optimize CT scanning protocol. (authors)

  2. Thick Slice and Thin Slice Teaching Evaluations

    Science.gov (United States)

    Tom, Gail; Tong, Stephanie Tom; Hesse, Charles

    2010-01-01

    Student-based teaching evaluations are an integral component to institutions of higher education. Previous work on student-based teaching evaluations suggest that evaluations of instructors based upon "thin slice" 30-s video clips of them in the classroom correlate strongly with their end of the term "thick slice" student evaluations. This study's…

  3. Effects of met-enkephalin on GABAergic spontaneous miniature IPSPs in organotypic slice cultures of the rat hippocampus

    DEFF Research Database (Denmark)

    Rekling, J C

    1993-01-01

    The action of met-enkephalin on GABAergic spontaneous miniature IPSPs (smIPSPs) was investigated in CA1 neurons from hippocampal slice cultures. In the presence of excitatory amino acid blockers (2,3-dihydroxy-6-nitro-7-sulphamoyl-benzo(F)quinoxaline, DL-2-amino-5-phosphonovaleric acid) and TTX...... the amplitude distribution of the smIPSPs. The proportion of "large" smIPSPs was reduced, but a loss of "small" smIPSPs also contributed to the reduction in smIPSP frequency. The selective mu-receptor agonist DAGO mimicked the effect of met-enkephalin and naloxone blocked the effect of DAGO. Hyperpolarization......IPSP frequency, nor did it block the effect of DAGO. These results suggest that CA1 pyramidal cells of hippocampal organotypic cultures are tonically inhibited by spontaneous release of GABA, through a release mechanism that is independent of propagated sodium action potentials. Met-enkephalin and DAGO reduce...

  4. Expression of hypoxia-inducible factor 1 alpha and oligodendrocyte lineage gene-1 in cultured brain slices after oxygen-glucose deprivation☆

    OpenAIRE

    Cui, Hong; Han, Weijuan; Yang, Lijun; Chang, Yanzhong

    2013-01-01

    Oligodendrocyte lineage gene-1 expressed in oligodendrocytes may trigger the repair of neuronal myelin impairment, and play a crucial role in myelin repair. Hypoxia-inducible factor 1α, a transcription factor, is of great significance in premature infants with hypoxic-ischemic brain damage. There is little evidence of direct regulatory effects of hypoxia-inducible factor 1α on oligodendrocyte lineage gene-1. In this study, brain slices of Sprague-Dawley rats were cultured and subjected to oxy...

  5. Architectural slicing

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2013-01-01

    Architectural prototyping is a widely used practice, con- cerned with taking architectural decisions through experiments with light- weight implementations. However, many architectural decisions are only taken when systems are already (partially) implemented. This is prob- lematic in the context...... of architectural prototyping since experiments with full systems are complex and expensive and thus architectural learn- ing is hindered. In this paper, we propose a novel technique for harvest- ing architectural prototypes from existing systems, \\architectural slic- ing", based on dynamic program slicing. Given...... a system and a slicing criterion, architectural slicing produces an architectural prototype that contain the elements in the architecture that are dependent on the ele- ments in the slicing criterion. Furthermore, we present an initial design and implementation of an architectural slicer for Java....

  6. Association of body mass index and the depletion of nigrostriatal dopamine in Parkinson's disease.

    Science.gov (United States)

    Lee, Jae Jung; Oh, Jungsu S; Ham, Jee H; Lee, Dong H; Lee, Injoo; Sohn, Young H; Kim, Jae S; Lee, Phil Hyu

    2016-02-01

    Several antecedent studies had reported close relationship between low body weight and Parkinson's disease (PD). However, there have been few investigations about the role of body weight to nigrostriatal dopaminergic neurodegeneration. This study enrolled 398 de novo patients with PD whom underwent [18F] N-(3-Fluoropropyl)-2β-carbon ethoxy-3β-(4-iodophenyl) nortropane positron emission tomography scan and body mass index (BMI) measurement. The relationships between BMI and dopamine transporter (DAT) activity were analyzed using linear regression analysis. A multivariate analysis adjusted for age, gender, disease duration, smoking status, coffee and tea consumption, and residence area revealed that BMI remained independently and significantly associated with DAT activity in all striatal subregions. Moreover, multiple logistic regression analyses showed that BMI was a significant predictor for the lowest quartile of DAT activity in the anterior putamen, ventral striatum, caudate nucleus, and total striatum. The present findings suggest that a low BMI might be closely associated with low density of nigrostriatal dopaminergic neurons in PD, which could support the evidence for the role of low body weight to PD-related pathologies. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Long-term, repeated dose in vitro neurotoxicity of the glutamate receptor antagonist L-AP3, demonstrated in rat hippocampal slice cultures by using continuous propidium iodide incubation.

    Science.gov (United States)

    Kristensen, Bjarne W; Blaabjerg, Morten; Noraberg, Jens; Zimmer, Jens

    2007-05-01

    Most in vitro models are only used to assess short-term effects of test compounds. However, as demonstrated here, hippocampal slice cultures can be used for long-term studies. The test compound used was the metabotropic glutamate receptor antagonist, L(+)-2-amino-3-phosphonopropionic acid (L-AP3), which is known to be toxic in vivo after subchronic, but not acute, administration. Degenerative effects were monitored by measuring the cellular uptake of propidium iodide (PI; continuously present in the medium) and lactate dehydrogenase (LDH) leakage, and by using a panel of histological stains. Hippocampal slices, derived from 2-3 day old rats and grown for 3 weeks, were subsequently exposed for the next 3 weeks to 0, 10 or 100microM L-AP3, with PI (2microM) in the culture medium. Exposure to 100microM L-AP3 induced severe toxicity after 4-6 days, shown by massive PI uptake, LDH leakage, changes in MAP2 and GFAP immunostaining, and in Nissl and Timm staining. In contrast, 10microM L-AP3 did not induce detectable neuronal degeneration. Treatment with the NMDA receptor antagonist, MK-801, or the AMPA/KA receptor antagonist NBQX, together with 100microM L-AP3, reduced neurodegeneration down to close to control values. It is concluded that continuous incubation of hippocampal slice cultures with PI is technically feasible for use in studies of inducible neuronal degeneration over time.

  8. Investigation of the therapeutic potential of N-acetyl cysteine and the tools used to define nigrostriatal degeneration in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Nouraei, Negin; Zarger, Lauren; Weilnau, Justin N.; Han, Jimin; Mason, Daniel M.; Leak, Rehana K., E-mail: leakr@duq.edu

    2016-04-01

    The glutathione precursor N-acetyl-L-cysteine (NAC) is currently being tested on Parkinson's patients for its neuroprotective properties. Our studies have shown that NAC can elicit protection in glutathione-independent manners in vitro. Thus, the goal of the present study was to establish an animal model of NAC-mediated protection in which to dissect the underlying mechanism. Mice were infused intrastriatally with the oxidative neurotoxicant 6-hydroxydopamine (6-OHDA; 4 μg) and administered NAC intraperitoneally (100 mg/kg). NAC-treated animals exhibited higher levels of the dopaminergic terminal marker tyrosine hydroxylase (TH) in the striatum 10d after 6-OHDA. As TH expression is subject to stress-induced modulation, we infused the tracer FluoroGold into the striatum to retrogradely label nigrostriatal projection neurons. As expected, nigral FluoroGold staining and cell counts of FluoroGold{sup +} profiles were both more sensitive measures of nigrostriatal degeneration than measurements relying on TH alone. However, NAC failed to protect dopaminergic neurons 3 weeks following 6-OHDA, an effect verified by four measures: striatal TH levels, nigral TH levels, nigral TH{sup +} cell counts, and nigral FluoroGold levels. Some degree of mild toxicity of FluoroGold and NAC was evident, suggesting that caution must be exercised when relying on FluoroGold as a neuron-counting tool and when designing experiments with long-term delivery of NAC—such as clinical trials on patients with chronic disorders. Finally, the strengths and limitations of the tools used to define nigrostriatal degeneration are discussed. - Highlights: • N-acetyl cysteine (NAC) was injected into animals infused with the toxicant 6-OHDA. • Retrograde tracing with FluoroGold was used to define nigrostriatal cell loss. • Infrared Odyssey imaging and cell counts were used to screen for nigral cell loss. • NAC protected transiently against 6-OHDA but this effect waned over time. • Mildly

  9. Outline and handling manual of experimental data time slice monitoring software 'SLICE'

    International Nuclear Information System (INIS)

    Shirai, Hiroshi; Hirayama, Toshio; Shimizu, Katsuhiro; Tani, Keiji; Azumi, Masafumi; Hirai, Ken-ichiro; Konno, Satoshi; Takase, Keizou.

    1993-02-01

    We have developed a software 'SLICE' which maps various kinds of plasma experimental data measured at the different geometrical position of JT-60U and JFT-2M onto the equilibrium magnetic configuration and treats them as a function of volume averaged minor radius ρ. Experimental data can be handled uniformly by using 'SLICE'. Plenty of commands of 'SLICE' make it easy to process the mapped data. The experimental data measured as line integrated values are also transformed by Abel inversion. The mapped data are fitted to a functional form and saved to the database 'MAPDB'. 'SLICE' can read the data from 'MAPDB' and re-display and transform them. Still more 'SLICE' creates run data of orbit following Monte-Carlo code 'OFMC' and tokamak predictive and interpretation code system 'TOPICS'. This report summarizes an outline and the usage of 'SLICE'. (author)

  10. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  11. FGF-2 deficiency does not influence FGF ligand and receptor expression during development of the nigrostriatal system.

    Science.gov (United States)

    Ratzka, Andreas; Baron, Olga; Grothe, Claudia

    2011-01-01

    Secreted proteins of the fibroblast growth factor (FGF) family play important roles during development of various organ systems. A detailed knowledge of their temporal and spatial expression profiles, especially of closely related FGF family members, are essential to further identification of specific functions in distinct tissues. In the central nervous system dopaminergic neurons of the substantia nigra and their axonal projections into the striatum progressively degenerate in Parkinson's disease. In contrast, FGF-2 deficient mice display increased numbers of dopaminergic neurons. In this study, we determined the expression profiles of all 22 FGF-ligands and 10 FGF-receptor isoforms, in order to clarify, if FGF-2 deficiency leads to compensatory up-regulation of other FGFs in the nigrostriatal system. Three tissues, ventral mesencephalon (VM), striatum (STR) and as reference tissue spinal cord (SC) of wild-type and FGF-2 deficient mice at four developmental stages E14.5, P0, P28, and adult were comparatively analyzed by quantitative RT-PCR. As no differences between the genotypes were observed, a compensatory up-regulation can be excluded. Moreover, this analysis revealed that the majority of FGF-ligands (18/22) and FGF-receptors (9/10) are expressed during normal development of the nigrostriatal system and identified dynamic changes for some family members. By comparing relative expression level changes to SC reference tissue, general alterations in all 3 tissues, such as increased expression of FGF-1, -2, -22, FgfR-2c, -3c and decreased expression of FGF-13 during postnatal development were identified. Further, specific changes affecting only one tissue, such as increased FGF-16 (STR) or decreased FGF-17 (VM) expression, or two tissues, such as decreased expression of FGF-8 (VM, STR) and FGF-15 (SC, VM) were found. Moreover, 3 developmentally down-regulated FGFs (FGF-8b, FGF-15, FGF-17a) were functionally characterized by plasmid-based over-expression in

  12. Minocycline Rescues from Zinc-Induced Nigrostriatal Dopaminergic Neurodegeneration: Biochemical and Molecular Interventions.

    Science.gov (United States)

    Kumar, Vinod; Singh, Brajesh Kumar; Chauhan, Amit Kumar; Singh, Deepali; Patel, Devendra Kumar; Singh, Chetna

    2016-07-01

    Accumulation of zinc (Zn) in dopaminergic neurons is implicated in Parkinson's disease (PD), and microglial activation plays a critical role in toxin-induced Parkinsonism. Oxidative stress is accused in Zn-induced dopaminergic neurodegeneration; however, its connection with microglial activation is still not known. This study was undertaken to elucidate the role and underlying mechanism of microglial activation in Zn-induced nigrostriatal dopaminergic neurodegeneration. Male Wistar rats were treated intraperitoneally with/without zinc sulphate (20 mg/kg) in the presence/absence of minocycline (30 mg/kg), a microglial activation inhibitor, for 2-12 weeks. While neurobehavioral and biochemical indexes of PD and number of dopaminergic neurons were reduced, the number of microglial cells was increased in the substantia nigra of the Zn-exposed animals. Similarly, Zn elevated lipid peroxidation (LPO) and activities of superoxide dismutase (SOD) and nicotinamide adenine dinucleotide phosphate (NADPH) oxidase; however, catalase activity was reduced. Besides, Zn increased an association of NADPH oxidase subunit p67(phox) with membrane, cytochrome c release from the mitochondria and cleavage of pro-caspase 3. Zn attenuated the expression of tyrosine hydroxylase (TH) and vesicular monoamine transporter-2 (VMAT-2) while augmented the expression of dopamine transporter (DAT) and heme oxygenase-1 (HO-1). Minocycline alleviated Zn-induced behavioural impairments, loss of TH-positive neurons, activated microglial cells and biochemical indexes and modulated the expression of studied genes/proteins towards normalcy. The results demonstrate that minocycline reduces the number of activated microglial cells and oxidative stress, which rescue from Zn-induced changes in the expression of monoamine transporter and nigrostriatal dopaminergic neurodegeneration.

  13. Blood cell oxidative stress precedes hemolysis in whole blood-liver slice co-cultures of rat, dog, and human tissues

    International Nuclear Information System (INIS)

    Vickers, Alison E.M.; Sinclair, John R.; Fisher, Robyn L.; Morris, Stephen R.; Way, William

    2010-01-01

    A novel in vitro model to investigate time-dependent and concentration-dependent responses in blood cells and hemolytic events is studied for rat, dog, and human tissues. Whole blood is co-cultured with a precision-cut liver slice. Methimazole (MMI) was selected as a reference compound, since metabolism of its imidazole thione moiety is linked with hematologic disorders and hepatotoxicity. An oxidative stress response occurred in all three species, marked by a decline in blood GSH levels by 24 h that progressed, and preceded hemolysis, which occurred at high MMI concentrations in the presence of a liver slice with rat (≥ 1000 μM at 48 h) and human tissues (≥ 1000 μM at 48 h, ≥ 750 μM at 72 h) but not dog. Human blood-only cultures exhibited a decline of GSH levels but minimal to no hemolysis. The up-regulation of liver genes for heme degradation (Hmox1 and Prdx1), iron cellular transport (Slc40a1), and GSH synthesis and utilization (mGST1 and Gclc) were early markers of the oxidative stress response. The up-regulation of the Kupffer cell lectin Lgals3 gene expression indicated a response to damaged red blood cells, and Hp (haptoglobin) up-regulation is indicative of increased hemoglobin uptake. Up-regulation of liver IL-6 and IL-8 gene expression suggested an activation of an inflammatory response by liver endothelial cells. In summary, MMI exposure led to an oxidative stress response in blood cells, and an up-regulation of liver genes involved with oxidative stress and heme homeostasis, which was clearly separate and preceded frank hemolysis.

  14. A brain slice bath for physiology and compound microscopy, with dual-sided perifusion.

    Science.gov (United States)

    Heyward, P M

    2010-12-01

    Contemporary in vitro brain slice studies can employ compound microscopes to identify individual neurons or their processes for physiological recording or imaging. This requires that the bath used to maintain the tissue fits within the working distances of a water-dipping objective and microscope condenser. A common means of achieving this is to maintain thin tissue slices on the glass floor of a recording bath, exposing only one surface of the tissue to oxygenated bathing medium. Emerging evidence suggests that physiology can be compromised by this approach. Flowing medium past both sides of submerged brain slices is optimal, but recording baths utilizing this principle are not readily available for use on compound microscopes. This paper describes a tissue bath designed specifically for microscopy and physiological recording, in which temperature-controlled medium flows past both sides of the slices. A particular feature of this design is the use of concentric mesh rings to support and transport the live tissue without mechanical disturbance. The design is also easily adapted for use with thin acute slices, cultured slices, and acutely dispersed or cultured cells maintained either on cover slips or placed directly on the floor of the bath. The low profile of the bath provides a low angle of approach for electrodes, and allows use of standard condensers, nosepieces and water-dipping objective lenses. If visualization of individual neurons is not required, the bath can be mounted on a simple stand and used with a dissecting microscope. Heating is integral to the bath, and any temperature controller capable of driving a resistive load can be used. The bath is robust, readily constructed and requires minimal maintenance. Full construction and operation details are given. © 2010 The Author Journal of Microscopy © 2010 The Royal Microscopical Society.

  15. Correlation between in vivo and in vitro pulmonary responses to jet propulsion fuel-8 using precision-cut lung slices and a dynamic organ culture system.

    Science.gov (United States)

    Hays, Allison M; Lantz, R Clark; Witten, Mark L

    2003-01-01

    In tissue slice models, interactions between the heterogeneous cell types comprising the lung parenchyma are maintained thus providing a controlled system for the study of pulmonary toxicology in vitro. However, validation of the model in vitro system must be affirmed. Previous reports, in in vivo systems, have demonstrated that Clara cells and alveolar type II cells are the targets following inhalation of JP-8 jet fuel. We have utilized the lung slice model to determine if cellular targets are similar following in vitro exposure to JP-8. Agar-filled adult rat lung explants were cored and precision cut, using the Brende/Vitron tissue slicer. Slices were cultured on titanium screens located as half-cylinders in cylindrical Teflon cradles that were loaded into standard scintillation vials and incubated at 37 degrees C. Slices were exposed to JP-8 jet fuel (0.5 mg/ml, 1.0 mg/ml, and 1.5 mg/ml in medium) for up to 24 hours. We determined ATP content using a luciferin-luciferase bioluminescent assay. No significant difference was found between the JP-8 jet fuel doses or time points, when compared to controls. Results were correlated with structural alterations following aerosol inhalation of JP-8. As a general observation, ultrastructural evaluation of alveolar type cells revealed an apparent increase in the number and size of surfactant secreting lamellar bodies that was JP-8 jet fuel-dose dependent. These results are similar to those observed following aerosol inhalation exposure. Thus, the lung tissue slice model appears to mimic in vivo effects of JP-8 and therefore is a useful model system for studying the mechanisms of lunginjury following JP-8 exposure.

  16. Precision cut lung slices as an efficient tool for in vitro lung physio-pharmacotoxicology studies.

    Science.gov (United States)

    Morin, Jean-Paul; Baste, Jean-Marc; Gay, Arnaud; Crochemore, Clément; Corbière, Cécile; Monteil, Christelle

    2013-01-01

    1.We review the specific approaches for lung tissue slices preparation and incubation systems and the research application fields in which lung slices proved to be a very efficient alternative to animal experimentation for biomechanical, physiological, pharmacological and toxicological approaches. 2.Focus is made on air-liquid interface dynamic organ culture systems that allow direct tissue exposure to complex aerosol and that best mimic in vivo lung tissue physiology. 3.A compilation of research applications in the fields of vascular and airway reactivity, mucociliary transport, polyamine transport, xenobiotic biotransformation, chemicals toxicology and complex aerosols supports the concept that precision cut lung slices are a very efficient tool maintaining highly differentiated functions similar to in vivo lung organ when kept under dynamic organ culture. They also have been successfully used for lung gene transfer efficiency assessment, for lung viral infection efficiency assessment, for studies of tissue preservation media and tissue post-conditioning to optimize lung tissue viability before grafting. 4.Taken all together, the reviewed studies point to a great interest for precision cut lung slices as an efficient and valuable alternative to in vivo lung organ experimentation.

  17. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction.

    Science.gov (United States)

    den Harder, J Chiel; van Yperen, Gert H; Blume, Ulrike A; Bos, Clemens

    2015-01-01

    Multispectral imaging (MSI) significantly reduces metal artifacts. Yet, especially in techniques that use gradient selection, such as slice encoding for metal artifact correction (SEMAC), a residual ripple artifact may be prominent. Here, an analysis is presented of the ripple artifact and of slice overlap as an approach to reduce the artifact. The ripple artifact was analyzed theoretically to clarify its cause. Slice overlap, conceptually similar to spectral bin overlap in multi-acquisition with variable resonances image combination (MAVRIC), was achieved by reducing the selection gradient and, thus, increasing the slice profile width. Time domain simulations and phantom experiments were performed to validate the analyses and proposed solution. Discontinuities between slices are aggravated by signal displacement in the frequency encoding direction in areas with deviating B0. Specifically, it was demonstrated that ripple artifacts appear only where B0 varies both in-plane and through-plane. Simulations and phantom studies of metal implants confirmed the efficacy of slice overlap to reduce the artifact. The ripple artifact is an important limitation of gradient selection based MSI techniques, and can be understood using the presented simulations. At a scan-time penalty, slice overlap effectively addressed the artifact, thereby improving image quality near metal implants. © 2014 Wiley Periodicals, Inc.

  18. Dopamine induces soluble α-synuclein oligomers and nigrostriatal degeneration.

    Science.gov (United States)

    Mor, Danielle E; Tsika, Elpida; Mazzulli, Joseph R; Gould, Neal S; Kim, Hanna; Daniels, Malcolm J; Doshi, Shachee; Gupta, Preetika; Grossman, Jennifer L; Tan, Victor X; Kalb, Robert G; Caldwell, Kim A; Caldwell, Guy A; Wolfe, John H; Ischiropoulos, Harry

    2017-11-01

    Parkinson's disease (PD) is defined by the loss of dopaminergic neurons in the substantia nigra and the formation of Lewy body inclusions containing aggregated α-synuclein. Efforts to explain dopamine neuron vulnerability are hindered by the lack of dopaminergic cell death in α-synuclein transgenic mice. To address this, we manipulated both dopamine levels and α-synuclein expression. Nigrally targeted expression of mutant tyrosine hydroxylase with enhanced catalytic activity increased dopamine levels without damaging neurons in non-transgenic mice. In contrast, raising dopamine levels in mice expressing human A53T mutant α-synuclein induced progressive nigrostriatal degeneration and reduced locomotion. Dopamine elevation in A53T mice increased levels of potentially toxic α-synuclein oligomers, resulting in conformationally and functionally modified species. Moreover, in genetically tractable Caenorhabditis elegans models, expression of α-synuclein mutated at the site of interaction with dopamine prevented dopamine-induced toxicity. These data suggest that a unique mechanism links two cardinal features of PD: dopaminergic cell death and α-synuclein aggregation.

  19. Portable Device Slices Thermoplastic Prepregs

    Science.gov (United States)

    Taylor, Beverly A.; Boston, Morton W.; Wilson, Maywood L.

    1993-01-01

    Prepreg slitter designed to slit various widths rapidly by use of slicing bar holding several blades, each capable of slicing strip of preset width in single pass. Produces material evenly sliced and does not contain jagged edges. Used for various applications in such batch processes involving composite materials as press molding and autoclaving, and in such continuous processes as pultrusion. Useful to all manufacturers of thermoplastic composites, and in slicing B-staged thermoset composites.

  20. A novel method for oxygen glucose deprivation model in organotypic spinal cord slices.

    Science.gov (United States)

    Liu, Jing-Jie; Ding, Xiao-Yan; Xiang, Li; Zhao, Feng; Huang, Sheng-Li

    2017-10-01

    This study aimed to establish a model to closely mimic spinal cord hypoxic-ischemic injury with high production and high reproducibility. Fourteen-day cultured organotypic spinal cord slices were divided into 4 groups: control (Ctrl), oxygen glucose deprived for 30min (OGD 30min), OGD 60min, and OGD 120min. The Ctrl slices were incubated with 1ml propidium iodide (PI) solution (5μg/ml) for 30min. The OGD groups were incubated with 1ml glucose-free DMEM/F12 medium and 5μl PI solution (1mg/ml) for 30min, 60min and 120min, respectively. Positive control slice was fixed by 4% paraformaldehyde for 20min. The culture medium in each group was then collected and the Lactate Dehydrogenase (LDH) level in the medium was tested using Multi-Analyte ELISArray kits. Structure and refraction of the spinal cord slices were observed by light microscope. Fluorescence intensity of PI was examined by fluorescence microscopy and was tested by IPP Software. Morphology of astrocytes was observed by immunofluorescence histochemistry. Caspase 3 and caspase 3 active in different groups were tested by Western blot. In the OGD groups, the refraction of spinal cord slices decreased and the structure was unclear. The changes of refraction and structure in the OGD 120min group were similar to that in the positive control slice. Astrocyte morphology changed significantly. With the increase of OGD time, processes became thick and twisted, and nuclear condensations became more apparent. Obvious changes in morphology were observed in the OGD 60min group, and normal morphology disappeared in the OGD 120min group. Fluorescence intensity of PI increased along with the extension of OGD time. The difference was significant between 30min and 60min, but not significant between 60min and 120min. The intensity at OGD 120min was close to that in the positive control. Compare with the Ctrl group, the OGD groups had significantly higher LDH levels and caspase 3 active/caspase 3 ratios. The values increased

  1. Visualizing form and function in organotypic slices of the adult mouse parotid gland.

    Science.gov (United States)

    Warner, Jennifer D; Peters, Christian G; Saunders, Rudel; Won, Jong Hak; Betzenhauser, Matthew J; Gunning, William T; Yule, David I; Giovannucci, David R

    2008-09-01

    An organotypic slice preparation of the adult mouse parotid salivary gland amenable to a variety of optical assessments of fluid and protein secretion dynamics is described. The semi-intact preparation rendered without the use of enzymatic treatment permitted live-cell imaging and multiphoton analysis of cellular and supracellular signals. Toward this end we demonstrated that the parotid slice is a significant addition to the repertoire of tools available to investigators to probe exocrine structure and function since there is currently no cell culture system that fully recapitulates parotid acinar cell biology. Importantly, we show that a subpopulation of the acinar cells of parotid slices can be maintained in short-term culture and retain their morphology and function for up to 2 days. This in vitro model system is a significant step forward compared with enzymatically dispersed acini that rapidly lose their morphological and functional characteristics over several hours, and it was shown to be long enough for the expression and trafficking of exogenous protein following adenoviral infection. This system is compatible with a variety of genetic and physiological approaches used to study secretory function.

  2. Fresh Slice Self-Seeding and Fresh Slice Harmonic Lasing at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.W. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2018-04-01

    We present results from the successful demonstration of fresh slice self-seeding at the Linac Coherent Light Source (LCLS).* The performance is compared with SASE and regular self-seeding at photon energy of 5.5 keV, resulting in a relative average brightness increase of a factor of 12 and a factor of 2 respectively. Following this proof-of-principle we discuss the forthcoming plans to use the same technique** for fresh slice harmonic lasing in an upcoming experiment. The demonstration of fresh slice harmonic lasing provides an attractive solution for future XFELs aiming to achieve high efficiency, high brightness X-ray pulses at high photon energies (>12 keV).***

  3. Flat slices in Minkowski space

    Science.gov (United States)

    Murchadha, Niall Ó.; Xie, Naqing

    2015-03-01

    Minkowski space, flat spacetime, with a distance measure in natural units of d{{s}2}=-d{{t}2}+d{{x}2}+d{{y}2}+d{{z}2}, or equivalently, with spacetime metric diag(-1, +1, +1, +1), is recognized as a fundamental arena for physics. The Poincaré group, the set of all rigid spacetime rotations and translations, is the symmetry group of Minkowski space. The action of this group preserves the form of the spacetime metric. Each t = constant slice of each preferred coordinate system is flat. We show that there are also nontrivial non-singular representations of Minkowski space with complete flat slices. If the embedding of the flat slices decays appropriately at infinity, the only flat slices are the standard ones. However, if we remove the decay condition, we find non-trivial flat slices with non-vanishing extrinsic curvature. We write out explicitly the coordinate transformation to a frame with such slices.

  4. Effects of Temperature and Slice Thickness on Drying Kinetics of Pumpkin Slices

    OpenAIRE

    Kongdej LIMPAIBOON

    2011-01-01

    Dried pumpkin slice is an alternative crisp food product. In this study, the effects of temperature and slice thickness on the drying characteristics of pumpkin were studied in a lab-scale tray dryer, using hot air temperatures of 55, 60 and 65 °C and 2, 3 and 4 mm slice thickness at a constant air velocity of 1.5 m/s. The initial moisture content of the pumpkin samples was 900.5 % (wb). The drying process was carried out until the final moisture content of product was 100.5 % (wb). The resul...

  5. Experimental demonstration of spectrum-sliced elastic optical path network (SLICE).

    Science.gov (United States)

    Kozicki, Bartłomiej; Takara, Hidehiko; Tsukishima, Yukio; Yoshimatsu, Toshihide; Yonenaga, Kazushige; Jinno, Masahiko

    2010-10-11

    We describe experimental demonstration of spectrum-sliced elastic optical path network (SLICE) architecture. We employ optical orthogonal frequency-division multiplexing (OFDM) modulation format and bandwidth-variable optical cross-connects (OXC) to generate, transmit and receive optical paths with bandwidths of up to 1 Tb/s. We experimentally demonstrate elastic optical path setup and spectrally-efficient transmission of multiple channels with bit rates ranging from 40 to 140 Gb/s between six nodes of a mesh network. We show dynamic bandwidth scalability for optical paths with bit rates of 40 to 440 Gb/s. Moreover, we demonstrate multihop transmission of a 1 Tb/s optical path over 400 km of standard single-mode fiber (SMF). Finally, we investigate the filtering properties and the required guard band width for spectrally-efficient allocation of optical paths in SLICE.

  6. The developmental expression of fluorescent proteins in organotypic hippocampal slice cultures from transgenic mice and its use in the determination of excitotoxic neurodegeneration

    DEFF Research Database (Denmark)

    Noraberg, Jens; Jensen, Carsten V; Bonde, Christian

    2007-01-01

    Transgenic mice, expressing fluorescent proteins in neurons and glia, provide new opportunities for real-time microscopic monitoring of degenerative and regenerative structural changes. We have previously validated and compared a number of quantifiable markers for neuronal damage and cell death...... changes, as well as the opportunity to monitor reversible changes or long-term effects in the event of minor damage. As a first step, we present: a) the developmental expression in organotypic hippocampal brain slice cultures of transgenic fluorescent proteins, useful for the visualisation of neuronal...... transgenic mouse strains which express fluorescent proteins in their neurons and/or astroglial cells. From the time of explantation, and subsequently for up to nine weeks in culture, the transgenic neuronal fluorescence displayed the expected characteristics of a developmental, in vivo-like increase...

  7. Brain stem slice conditioned medium contains endogenous BDNF and GDNF that affect neural crest boundary cap cells in co-culture.

    Science.gov (United States)

    Kaiser, Andreas; Kale, Ajay; Novozhilova, Ekaterina; Siratirakun, Piyaporn; Aquino, Jorge B; Thonabulsombat, Charoensri; Ernfors, Patrik; Olivius, Petri

    2014-05-30

    Conditioned medium (CM), made by collecting medium after a few days in cell culture and then re-using it to further stimulate other cells, is a known experimental concept since the 1950s. Our group has explored this technique to stimulate the performance of cells in culture in general, and to evaluate stem- and progenitor cell aptitude for auditory nerve repair enhancement in particular. As compared to other mediums, all primary endpoints in our published experimental settings have weighed in favor of conditioned culture medium, where we have shown that conditioned culture medium has a stimulatory effect on cell survival. In order to explore the reasons for this improved survival we set out to analyze the conditioned culture medium. We utilized ELISA kits to investigate whether brain stem (BS) slice CM contains any significant amounts of brain-derived neurotrophic factor (BDNF) and glial cell derived neurotrophic factor (GDNF). We further looked for a donor cell with progenitor characteristics that would be receptive to BDNF and GDNF. We chose the well-documented boundary cap (BC) progenitor cells to be tested in our in vitro co-culture setting together with cochlear nucleus (CN) of the BS. The results show that BS CM contains BDNF and GDNF and that survival of BC cells, as well as BC cell differentiation into neurons, were enhanced when BS CM were used. Altogether, we conclude that BC cells transplanted into a BDNF and GDNF rich environment could be suitable for treatment of a traumatized or degenerated auditory nerve. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. The virtual slice setup.

    Science.gov (United States)

    Lytton, William W; Neymotin, Samuel A; Hines, Michael L

    2008-06-30

    In an effort to design a simulation environment that is more similar to that of neurophysiology, we introduce a virtual slice setup in the NEURON simulator. The virtual slice setup runs continuously and permits parameter changes, including changes to synaptic weights and time course and to intrinsic cell properties. The virtual slice setup permits shocks to be applied at chosen locations and activity to be sampled intra- or extracellularly from chosen locations. By default, a summed population display is shown during a run to indicate the level of activity and no states are saved. Simulations can run for hours of model time, therefore it is not practical to save all of the state variables. These, in any case, are primarily of interest at discrete times when experiments are being run: the simulation can be stopped momentarily at such times to save activity patterns. The virtual slice setup maintains an automated notebook showing shocks and parameter changes as well as user comments. We demonstrate how interaction with a continuously running simulation encourages experimental prototyping and can suggest additional dynamical features such as ligand wash-in and wash-out-alternatives to typical instantaneous parameter change. The virtual slice setup currently uses event-driven cells and runs at approximately 2 min/h on a laptop.

  9. Magnetic Resonance Imaging Features of the Nigrostriatal System: Biomarkers of Parkinson’s Disease Stages?

    Science.gov (United States)

    Hopes, Lucie; Grolez, Guillaume; Moreau, Caroline; Lopes, Renaud; Ryckewaert, Gilles; Carrière, Nicolas; Auger, Florent; Laloux, Charlotte; Petrault, Maud; Devedjian, Jean-Christophe; Bordet, Regis; Defebvre, Luc; Jissendi, Patrice; Delmaire, Christine; Devos, David

    2016-01-01

    Introduction Magnetic resonance imaging (MRI) can be used to identify biomarkers in Parkinson’s disease (PD); R2* values reflect iron content related to high levels of oxidative stress, whereas volume and/or shape changes reflect neuronal death. We sought to assess iron overload in the nigrostriatal system and characterize its relationship with focal and overall atrophy of the striatum in the pivotal stages of PD. Methods Twenty controls and 70 PD patients at different disease stages (untreated de novo patients, treated early-stage patients and advanced-stage patients with L-dopa-related motor complications) were included in the study. We determined the R2* values in the substantia nigra, putamen and caudate nucleus, together with striatal volume and shape analysis. We also measured R2* in an acute MPTP mouse model and in a longitudinal follow-up two years later in the early-stage PD patients. Results The R2* values in the substantia nigra, putamen and caudate nucleus were significantly higher in de novo PD patients than in controls. Early-stage patients displayed significantly higher R2* values in the substantia nigra (with changes in striatal shape), relative to de novo patients. Measurements after a two-year follow-up in early-stage patients and characterization of the acute MPTP mouse model confirmed that R2* changed rapidly with disease progression. Advanced-stage patients displayed significant atrophy of striatum, relative to earlier disease stages. Conclusion Each pivotal stage in PD appears to be characterized by putative nigrostriatal MRI biomarkers: iron overload at the de novo stage, striatal shape changes at early-stage disease and generalized striatal atrophy at advanced disease. PMID:27035571

  10. 3-nitropropionic acid neurotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Noer, Helle; Kristensen, Bjarne W; Noraberg, Jens

    2002-01-01

    : CA1 > CA3 > fascia dentata. In low glucose much lower concentrations of 3-NP (25 microM) triggered neurotoxicity. One-week-old cultures were less susceptible to 3-NP toxicity than 3-week-old cultures, but the dentate granule cells were relatively more affected in the immature cultures. We found...

  11. Running wheel exercise enhances recovery from nigrostriatal dopamine injury without inducing neuroprotection.

    Science.gov (United States)

    O'Dell, S J; Gross, N B; Fricks, A N; Casiano, B D; Nguyen, T B; Marshall, J F

    2007-02-09

    Forced use of the forelimb contralateral to a unilateral injection of the dopaminergic neurotoxin 6-hydroxydopamine can promote recovery of motor function in that limb and can significantly decrease damage to dopamine terminals. The present study was conducted to determine (1) whether a form of voluntary exercise, wheel running, would improve motor performance in rats with such lesions, and (2) whether any beneficial effects of wheel running are attributable to ameliorating the dopaminergic damage. In experiment 1, rats were allowed to run in exercise wheels or kept in home cages for 2 1/2 weeks, then given stereotaxic infusions of 6-hydroxydopamine into the left striatum. The rats were replaced into their original environments (wheels or home cages) for four additional weeks, and asymmetries in forelimb use were quantified at 3, 10, 17, and 24 days postoperatively. After killing, dopaminergic damage was assessed by both quantifying 3 beta-(4-iodophenyl)tropan-2 beta-carboxylic acid methyl ester ([(125)I]RTI-55) binding to striatal dopamine transporters and counting tyrosine hydroxylase-positive cells in the substantia nigra. Exercised 6-hydroxydopamine-infused rats showed improved motor outcomes relative to sedentary lesioned controls, effects that were most apparent at postoperative days 17 and 24. Despite this behavioral improvement, 6-hydroxydopamine-induced loss of striatal dopamine transporters and tyrosine hydroxylase-positive nigral cells in exercised and sedentary groups did not differ. Since prior studies suggested that forced limb use improves motor performance by sparing nigrostriatal dopaminergic neurons from 6-hydroxydopamine damage, experiment 2 used a combined regimen of forced plus voluntary wheel running. Again, we found that the motor performance of exercised rats improved more rapidly than that of sedentary controls, but that there were no differences between these groups in the damage produced by 6-hydroxydopamine. It appears that voluntary

  12. Thin-Slice Measurement of Wisdom

    Directory of Open Access Journals (Sweden)

    Chao S. Hu

    2017-08-01

    Full Text Available Objective Measurement of Wisdom within a short period of time is vital for both the public interest (e.g., understanding a presidential election and research (e.g., testing factors that facilitate wisdom development. A measurement of emotion associated with wisdom would be especially informative; therefore, a novel Thin-Slice measurement of wisdom was developed based on the Berlin Paradigm. For about 2 min, participants imagined the lens of a camera as the eyes of their friend/teacher whom they advised about a life dilemma. Verbal response and facial expression were both recorded by a camera: verbal responses were then rated on both the Berlin Wisdom criteria and newly developed Chinese wisdom criteria; facial expressions were analyzed by the software iMotion FACET module. Results showed acceptable inter-rater and inter-item reliability for this novel paradigm. Moreover, both wisdom ratings were not significantly correlated with Social desirability, and the Berlin wisdom rating was significantly negatively correlated with Neuroticism; feeling of surprise was significantly positively correlated with both wisdom criteria ratings. Our results provide the first evidence of this Thin-slice Wisdom Paradigm’s reliability, its immunity to social desirability, and its validity for assessing candidates’ wisdom within a short timeframe. Although still awaiting further development, this novel Paradigm contributes to an emerging Universal Wisdom Paradigm applicable across cultures.

  13. Neuroprotective Effects of α-Tocotrienol on Kainic Acid-Induced Neurotoxicity in Organotypic Hippocampal Slice Cultures

    Directory of Open Access Journals (Sweden)

    Bae Hwan Lee

    2013-09-01

    Full Text Available Vitamin E, such as alpha-tocopherol (ATPH and alpha-tocotrienol (ATTN, is a chain-breaking antioxidant that prevents the chain propagation step during lipid peroxidation. In the present study, we investigated the effects of ATTN on KA-induced neuronal death using organotypic hippocampal slice culture (OHSC and compared the neuroprotective effects of ATTN and ATPH. After 15 h KA (5 µM treatment, delayed neuronal death was detected in the CA3 region and reactive oxygen species (ROS formation and lipid peroxidation were also increased. Both co-treatment and post-treatment of ATPH (100 µM or ATTN (100 µM significantly increased the cell survival and reduced the number of TUNEL-positive cells in the CA3 region. Increased dichlorofluorescein (DCF fluorescence and levels of thiobarbiturate reactive substances (TBARS were decreased by ATPH and ATTN treatment. These data suggest that ATPH and ATTN treatment have protective effects on KA-induced cell death in OHSC. ATTN treatment tended to be more effective than ATPH treatment, even though there was no significant difference between ATPH and ATTN in co-treatment or post-treatment.

  14. Brain Slice Staining and Preparation for Three-Dimensional Super-Resolution Microscopy

    Science.gov (United States)

    German, Christopher L.; Gudheti, Manasa V.; Fleckenstein, Annette E.; Jorgensen, Erik M.

    2018-01-01

    Localization microscopy techniques – such as photoactivation localization microscopy (PALM), fluorescent PALM (FPALM), ground state depletion (GSD), and stochastic optical reconstruction microscopy (STORM) – provide the highest precision for single molecule localization currently available. However, localization microscopy has been largely limited to cell cultures due to the difficulties that arise in imaging thicker tissue sections. Sample fixation and antibody staining, background fluorescence, fluorophore photoinstability, light scattering in thick sections, and sample movement create significant challenges for imaging intact tissue. We have developed a sample preparation and image acquisition protocol to address these challenges in rat brain slices. The sample preparation combined multiple fixation steps, saponin permeabilization, and tissue clarification. Together, these preserve intracellular structures, promote antibody penetration, reduce background fluorescence and light scattering, and allow acquisition of images deep in a 30 μm thick slice. Image acquisition challenges were resolved by overlaying samples with a permeable agarose pad and custom-built stainless steel imaging adapter, and sealing the imaging chamber. This approach kept slices flat, immobile, bathed in imaging buffer, and prevented buffer oxidation during imaging. Using this protocol, we consistently obtained single molecule localizations of synaptic vesicle and active zone proteins in three-dimensions within individual synaptic terminals of the striatum in rat brain slices. These techniques may be easily adapted to the preparation and imaging of other tissues, substantially broadening the application of super-resolution imaging. PMID:28924666

  15. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    International Nuclear Information System (INIS)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M.; Wagstaff, Anne W.; Smeltzer, Matthew P.; Krafft, Axel J.; Hankins, Jane S.

    2017-01-01

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  16. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Wagstaff, Anne W. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Rhodes College, Memphis, TN (United States); University of Alabama at Birmingham School of Medicine, Birmingham, AL (United States); Smeltzer, Matthew P. [St. Jude Children' s Research Hospital, Department of Biostatistics, Memphis, TN (United States); University of Memphis, Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, Memphis, TN (United States); Krafft, Axel J. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); University Hospital Center Freiburg, Department of Radiology, Freiburg (Germany); Hankins, Jane S. [St. Jude Children' s Research Hospital, Department of Hematology, Memphis, TN (United States)

    2017-01-15

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  17. Comparison of 640-Slice Multidetector Computed Tomography Versus 32-Slice MDCT for Imaging of the Osteo-odonto-keratoprosthesis Lamina.

    Science.gov (United States)

    Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C

    2015-08-01

    To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.

  18. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  19. Ibuprofen abates cypermethrin-induced expression of pro-inflammatory mediators and mitogen-activated protein kinases and averts the nigrostriatal dopaminergic neurodegeneration.

    Science.gov (United States)

    Singh, Ashish; Tripathi, Pratibha; Prakash, Om; Singh, Mahendra Pratap

    2016-12-01

    Cypermethrin induces oxidative stress, microglial activation, inflammation and apoptosis leading to Parkinsonism in rats. While ibuprofen, a non-steroidal anti-inflammatory drug, relieves from inflammation, its efficacy against cypermethrin-induced Parkinsonism has not yet been investigated. The study aimed to explore the protective role of ibuprofen in cypermethrin-induced Parkinsonism, an environmentally relevant model of Parkinson's disease (PD), along with its underlying mechanism. Animals were treated with/without cypermethrin in the presence/absence of ibuprofen. Behavioural, immunohistochemical and biochemical parameters of Parkinsonism and expression of pro-inflammatory and pro-apoptotic proteins along with mitogen-activated protein kinases (MAPKs) were determined. Ibuprofen resisted cypermethrin-induced behavioural impairments, striatal dopamine depletion, oxidative stress in the nigrostriatal tissues and loss of the nigral dopamine producing cells and increase in microglial activation along with atypical expression of pro-inflammatory and apoptotic proteins that include cyclooxygenase-2, tumour necrosis factor-α, MAPKs (c-Jun N-terminal kinase, p38 and extracellular signal-regulated kinase), B cell lymphoma 2-associated protein X, tumour suppressor protein p53, cytochrome c and caspase-3 in the nigrostriatal tissue. The results obtained thus demonstrate that ibuprofen lessens inflammation and regulates MAPKs expression thereby averts cypermethrin-induced Parkinsonism.

  20. Precision-cut intestinal slices as a culture system to analyze the infection of differentiated intestinal epithelial cells by avian influenza viruses.

    Science.gov (United States)

    Punyadarsaniya, Darsaniya; Winter, Christine; Mork, Ann-Kathrin; Amiri, Mahdi; Naim, Hassan Y; Rautenschlein, Silke; Herrler, Georg

    2015-02-01

    Many viruses infect and replicate in their host via the intestinal tract, e.g. many picornaviruses, several coronaviruses and avian influenza viruses of waterfowl. To analyze infection of enterocytes is a challenging task as culture systems for differentiated intestinal epithelial cells are not readily available and often have a life span that is too short for infection studies. Precision-cut intestinal slices (PCIS) from chicken embryos were prepared and shown that the epithelial cells lining the lumen of the intestine are viable for up to 4 days. Using lectin staining, it was demonstrated that α2,3-linked sialic acids, the preferred receptor determinants of avian influenza viruses, are present on the apical side of the epithelial cells. Furthermore, the epithelial cells (at the tips) of the villi were shown to be susceptible to infection by an avian influenza virus of the H9N2 subtype. This culture system will be useful to analyze virus infection of intestinal epithelial cells and it should be applicable also to the intestine of other species. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Discerning cultural identification from a thinly sliced behavioral sample.

    Science.gov (United States)

    Hamamura, Takeshi; Li, Liman Man Wai

    2012-12-01

    This research examined whether individual differences in cultural identification can be discerned at zero acquaintance. This issue was examined in Hong Kong, where the idiosyncrasy of cultural identification is a salient social-psychological issue. The participants were able to perceive accurately the targets' identification with Western culture from a video clip and from a still image. Findings also indicated that a stereotype of Western cultural identity (i.e., extraversion and particular hairstyle) facilitated these perceptions. Specifically, (a) the participants with a stronger stereotype were more accurate in perceiving Western cultural identification, (b) the targets who were experimentally manipulated to appear extraverted were rated as more strongly identifying with Western culture, and (c) the participants relatively unfamiliar with these stereotypes did not correctly perceive Western cultural identification. Implications of these findings on research on multiculturalism are also discussed.

  2. Reduced TH expression and α-synuclein accumulation contribute towards nigrostriatal dysfunction in experimental hepatic encephalopathy.

    Science.gov (United States)

    Suárez, Isabel; Bodega, Guillermo; Rubio, Miguel; Fernández, Benjamín

    2017-01-01

    The present work examines α-synuclein expression in the nigrostriatal system of a rat chronic hepatic encephalopathy model induced by portacaval anastomosis (PCA). There is evidence that dopaminergic dysfunction in disease conditions is strongly associated with such expression. Possible relationships among dopaminergic neurons, astroglial cells and α-synuclein expression were sought. Brain tissue samples from rats at 1 and 6 months post-PCA, and controls, were analysed immunohistochemically using antibodies against tyrosine hydroxylase (TH), α-synuclein, glial fibrillary acidic protein (GFAP) and ubiquitin (Ub). In the control rats, TH immunoreactivity was detected in the neuronal cell bodies and processes in the substantia nigra pars compacta (SNc). A dense TH-positive network of neurons was also seen in the striatum. In the PCA-exposed rats, however, a reduction in TH-positive neurons was seen at both 1 and 6 months in the SNc, as well as a reduction in TH-positive fibres in the striatum. This was coincident with the appearance of α-synuclein-immunoreactive neurons in the SNc; some of the TH-positive neurons also showed α-synuclein immunoreactivity. In addition, α-synuclein accumulation was seen in the SNc and striatum at both 1 and 6 months post-PCA, whereas α-synuclein was only mildly expressed in the nigrostriatal pathway of the controls. Astrogliosis was also seen following PCA, as revealed by increased GFAP expression from 1 month to 6 months post-PCA in both the SN and striatum. The astroglial activation level in the SN paralleled the reduced neuronal expression of TH throughout PCA exposure. α-synuclein accumulation following PCA may induce dopaminergic dysfunction via the downregulation of TH, as well as astroglial activation.

  3. Cytotoxicity of retinoic acid, menadione and aflatoxin B1 in rat liver slices using netwell inserts as a culture system

    NARCIS (Netherlands)

    Leeman, W.R.; Gevel, I.A. van de; Rutten, A.A.J.J.L.

    1995-01-01

    Precision-cut rat liver slices were used to develop a new dynamic incubation system in which histomorphology and measurement of the release of lactate dehydrogenase (LDH) and the conversion of MTT were applied to evaluate cytotoxicity. Liver slices, precision-cut using a Krumdieck tissue slicer,

  4. The energy demand of fast neuronal network oscillations: insights from brain slice preparations

    Directory of Open Access Journals (Sweden)

    Oliver eKann

    2012-01-01

    Full Text Available Fast neuronal network oscillations in the gamma range (30-100 Hz in the cerebral cortex have been implicated in higher cognitive functions such as sensual perception, working memory, and, perhaps, consciousness. However, little is known about the energy demand of gamma oscillations. This is mainly caused by technical limitations that are associated with simultaneous recordings of neuronal activity and energy metabolism in small neuronal networks and at the level of mitochondria in vivo. Thus recent studies have focused on brain slice preparations to address the energy demand of gamma oscillations in vitro. Here, reports will be summarized and discussed that combined electrophysiological recordings, oxygen sensor microelectrodes and live-cell fluorescence imaging in acutely prepared slices and organotypic slice cultures of the hippocampus from both, mouse and rat. These reports consistently show that gamma oscillations can be reliably induced in hippocampal slice preparations by different pharmacological tools. They suggest that gamma oscillations are associated with high energy demand, requiring both rapid adaptation of oxidative energy metabolism and sufficient supply with oxygen and nutrients. These findings might help to explain the exceptional vulnerability of higher cognitive functions during pathological processes of the brain, such as circulatory disturbances, genetic mitochondrial diseases, and neurodegeneration.

  5. A protocol for preparation and transfection of rat entorhinal cortex organotypic cultures for electrophysiological whole-cell recordings

    Directory of Open Access Journals (Sweden)

    Nicholas I. Cilz

    2017-01-01

    Full Text Available Understanding how neuromodulators influence synaptic transmission and intrinsic excitability within the entorhinal cortex (EC is critical to furthering our understanding of the molecular and cellular aspects of this region. Organotypic cultures can provide a cost-effective means to employ selective molecular biological strategies in elucidating cellular mechanisms of neuromodulation in the EC. We therefore adapted our acute slice model for organotypic culture applications and optimized a protocol for the preparation and biolistic transfection of cultured horizontal EC slices. Here, we present our detailed protocol for culturing EC slices. Using an n-methyl-d-glucamine (NMDG-containing cutting solution, we obtain healthy EC slice cultures for electrophysiological recordings. We also present our protocol for the preparation of “bullets” carrying one or more constructs and demonstrate successful transfection of EC slices. We build upon previous methods and highlight specific aspects in our method that greatly improved the quality of our results. We validate our methods using immunohistochemical, imaging, and electrophysiological techniques. The novelty of this method is that it provides a description of culturing and transfection of EC neurons for specifically addressing their functionality. This method will enable researchers interested in entorhinal function to quickly adopt a similar slice culture transfection system for their own investigations.

  6. Lipopolysaccharide does not alter small airway reactivity in mouse lung slices.

    Science.gov (United States)

    Donovan, Chantal; Royce, Simon G; Vlahos, Ross; Bourke, Jane E

    2015-01-01

    The bacterial endotoxin, lipopolysaccharide (LPS) has been associated with occupational airway diseases with asthma-like symptoms and in acute exacerbations of COPD. The direct and indirect effects of LPS on small airway reactivity have not been fully elucidated. We tested the hypothesis that both in vitro and in vivo LPS treatment would increase contraction and impair relaxation of mouse small airways. Lung slices were prepared from naïve Balb/C mice and cultured in the absence or presence of LPS (10 μg/ml) for up to 48 h for measurement of TNFα levels in conditioned media. Alternatively, mice were challenged with PBS or LPS in vivo once a day for 4 days for preparation of lung slices or for harvest of lungs for Q-PCR analysis of gene expression of pro-inflammatory cytokines and receptors involved in airway contraction. Reactivity of small airways to contractile agonists, methacholine and serotonin, and bronchodilator agents, salbutamol, isoprenaline and rosiglitazone, were assessed using phase-contrast microscopy. In vitro LPS treatment of slices increased TNFα release 6-fold but did not alter contraction or relaxation to any agonists tested. In vivo LPS treatment increased lung gene expression of TNFα, IL-1β and ryanodine receptor isoform 2 more than 5-fold. However there were no changes in reactivity in lung slices from these mice, even when also incubated with LPS ex vivo. Despite evidence of LPS-induced inflammation, neither airway hyperresponsiveness or impaired dilator reactivity were evident. The increase in ryanodine receptor isoform 2, known to regulate calcium signaling in vascular smooth muscle, warrants investigation. Since LPS failed to elicit changes in small airway reactivity in mouse lung slices following in vitro or in vivo treatment, alternative approaches are required to define the potential contribution of this endotoxin to altered small airway reactivity in human lung diseases.

  7. Lipopolysaccharide does not alter small airway reactivity in mouse lung slices.

    Directory of Open Access Journals (Sweden)

    Chantal Donovan

    Full Text Available The bacterial endotoxin, lipopolysaccharide (LPS has been associated with occupational airway diseases with asthma-like symptoms and in acute exacerbations of COPD. The direct and indirect effects of LPS on small airway reactivity have not been fully elucidated. We tested the hypothesis that both in vitro and in vivo LPS treatment would increase contraction and impair relaxation of mouse small airways. Lung slices were prepared from naïve Balb/C mice and cultured in the absence or presence of LPS (10 μg/ml for up to 48 h for measurement of TNFα levels in conditioned media. Alternatively, mice were challenged with PBS or LPS in vivo once a day for 4 days for preparation of lung slices or for harvest of lungs for Q-PCR analysis of gene expression of pro-inflammatory cytokines and receptors involved in airway contraction. Reactivity of small airways to contractile agonists, methacholine and serotonin, and bronchodilator agents, salbutamol, isoprenaline and rosiglitazone, were assessed using phase-contrast microscopy. In vitro LPS treatment of slices increased TNFα release 6-fold but did not alter contraction or relaxation to any agonists tested. In vivo LPS treatment increased lung gene expression of TNFα, IL-1β and ryanodine receptor isoform 2 more than 5-fold. However there were no changes in reactivity in lung slices from these mice, even when also incubated with LPS ex vivo. Despite evidence of LPS-induced inflammation, neither airway hyperresponsiveness or impaired dilator reactivity were evident. The increase in ryanodine receptor isoform 2, known to regulate calcium signaling in vascular smooth muscle, warrants investigation. Since LPS failed to elicit changes in small airway reactivity in mouse lung slices following in vitro or in vivo treatment, alternative approaches are required to define the potential contribution of this endotoxin to altered small airway reactivity in human lung diseases.

  8. Morphological and metabolic changes in the nigro-striatal pathway of synthetic proteasome inhibitor (PSI-treated rats: a MRI and MRS study.

    Directory of Open Access Journals (Sweden)

    Stefano Delli Pizzi

    Full Text Available Systemic administration of a Synthetic Proteasome Inhibitor (PSI in rats has been described as able to provide a model of Parkinson's disease (PD, characterized by behavioral and biochemical modifications, including loss of dopaminergic neurons in the substantia nigra (SN, as assessed by post-mortem studies. With the present study we aimed to assess in-vivo by Magnetic Resonance (MR possible morphological and metabolic changes in the nigro-striatal pathway of PSI-treated rats. 10 animals were subcutaneously injected with PSI 6.0 mg/kg dissolved in DMSO 100%. Injections were made thrice weekly over the course of two weeks. 5 more animals injected with DMSO 100% with the same protocol served as controls. The animals underwent MR sessions before and at four weeks after the end of treatment with either PSI or vehicle. MR Imaging was performed to measure SN volume and Proton MR Spectroscopy ((1H-MRS was performed to measure metabolites changes at the striatum. Animals were also assessed for motor function at baseline and at 4 and 6 weeks after treatment. Dopamine and dopamine metabolite levels were measured in the striata at 6 weeks after treatment. PSI-treated animals showed volumetric reduction of the SN (p<0.02 at 4 weeks after treatment as compared to baseline. Immunofluorescence analysis confirmed MRI changes in SN showing a reduction of tyrosine hydroxylase expression as compared to neuron-specific enolase expression. A reduction of N-acetyl-aspartate/total creatine ratio (p = 0.05 and an increase of glutamate-glutamine-γ amminobutirrate/total creatine were found at spectroscopy (p = 0.03. At 6 weeks after treatment, PSI-treated rats also showed motor dysfunction compared to baseline (p = 0.02, accompanied by dopamine level reduction in the striatum (p = 0.02. Treatment with PSI produced morphological and metabolic modifications of the nigro-striatal pathway, accompanied by motor dysfunction. MR demonstrated to be a powerful mean to assess in

  9. Iron Chelators and Antioxidants Regenerate Neuritic Tree and Nigrostriatal Fibers of MPP+/MPTP-Lesioned Dopaminergic Neurons.

    Directory of Open Access Journals (Sweden)

    Pabla Aguirre

    Full Text Available Neuronal death in Parkinson's disease (PD is often preceded by axodendritic tree retraction and loss of neuronal functionality. The presence of non-functional but live neurons opens therapeutic possibilities to recover functionality before clinical symptoms develop. Considering that iron accumulation and oxidative damage are conditions commonly found in PD, we tested the possible neuritogenic effects of iron chelators and antioxidant agents. We used three commercial chelators: DFO, deferiprone and 2.2'-dypyridyl, and three 8-hydroxyquinoline-based iron chelators: M30, 7MH and 7DH, and we evaluated their effects in vitro using a mesencephalic cell culture treated with the Parkinsonian toxin MPP+ and in vivo using the MPTP mouse model. All chelators tested promoted the emergence of new tyrosine hydroxylase (TH-positive processes, increased axodendritic tree length and protected cells against lipoperoxidation. Chelator treatment resulted in the generation of processes containing the presynaptic marker synaptophysin. The antioxidants N-acetylcysteine and dymetylthiourea also enhanced axodendritic tree recovery in vitro, an indication that reducing oxidative tone fosters neuritogenesis in MPP+-damaged neurons. Oral administration to mice of the M30 chelator for 14 days after MPTP treatment resulted in increased TH- and GIRK2-positive nigra cells and nigrostriatal fibers. Our results support a role for oral iron chelators as good candidates for the early treatment of PD, at stages of the disease where there is axodendritic tree retraction without neuronal death.

  10. Radiation sterilization and identification of gizzard slices

    International Nuclear Information System (INIS)

    Zhu, S.; Fu, C.; Jiang, W.; Yao, D.; Zhao, K.; Zhang, Y.

    1998-01-01

    An orthogonal test of 4 factors of radiation dose, storage temperature, storage time, and sanitation of cutting places was carried out to optimize the conditions for disinfection of gizzard slices. In the optimized condition, both the sanitary quality and the shelf-life of gizzard slices were improved. To identify irradiated gizzard slices, the sensory change, and the levels of water-soluble nitrogen, amino acid, total volatile basic nitrogen, peroxide value, vitamin C consumption and KMnO 4 consumption were determinated. No significant change was observed except for the color which was light brown on the surface of irradiated slices

  11. Slice hyperholomorphic Schur analysis

    CERN Document Server

    Alpay, Daniel; Sabadini, Irene

    2016-01-01

    This book defines and examines the counterpart of Schur functions and Schur analysis in the slice hyperholomorphic setting. It is organized into three parts: the first introduces readers to classical Schur analysis, while the second offers background material on quaternions, slice hyperholomorphic functions, and quaternionic functional analysis. The third part represents the core of the book and explores quaternionic Schur analysis and its various applications. The book includes previously unpublished results and provides the basis for new directions of research.

  12. Maintenance of adult primate liver in organ culture: Potential use in toxicity testing

    International Nuclear Information System (INIS)

    Smith, P.F.; O'Brien, K.A.; Allen, L.; DeLuca, J.; Norman, B.; Keenan, K.P.

    1991-01-01

    Adult Rhesus monkey liver slices were incubated using a dynamic organ culture method to determine hepatocyte viability, drug biotransformation potential and the in vitro response to the hepatotoxicant, allyl alcohol (AA). After 1, 2, 4, or 8 hr, slices were removed from culture and analyzed for incorporation of [ 3 H]-leucine into acid-precipitable material, and medium alanine aminotransferase (ALT) activity was determined. Separate slices were taken for histological evaluation and for evaluation of microsomal 7-ethoxy-4-trifluoromethyl coumarin-O-deethylase (EFCOD) activity. Incorporation of [ 3 H]-leucine into slices was linear over the period of incubation and was specifically inhibited by cycloheximide (10 uM) at all time points. In the absence of AA, enzyme leakage was minimal over 8 hr. Marked ALT leakage occurred with 1 mM AA. Control slices had an initial fall to 55% of in vivo EFCOD activity that stabilized at 40-50% control slices indicated that there was minimal cellular degeneration and that, in PAS-stained sections, glycogen accumulation occurred over the incubation period. This system allows for maintenance and viability of adult primate liver slices in culture for at least 8 hr and may be useful for in vitro toxicity and biotransformation studies

  13. Multiple single-unit long-term tracking on organotypic hippocampal slices using high-density microelectrode arrays

    Directory of Open Access Journals (Sweden)

    Wei Gong

    2016-11-01

    Full Text Available A novel system to cultivate and record from organotypic brain slices directly on high-density microelectrode arrays (HD-MEA was developed. This system allows for continuous recording of electrical activity of specific individual neurons at high spatial resolution while monitoring at the same time, neuronal network activity. For the first time, the electrical activity patterns of single neurons and the corresponding neuronal network in an organotypic hippocampal slice culture were studied during several consecutive weeks at daily intervals. An unsupervised iterative spike-sorting algorithm, based on PCA and k-means clustering, was developed to assign the activities to the single units. Spike-triggered average extracellular waveforms of an action potential recorded across neighboring electrodes, termed ‘footprints’ of single-units were generated and tracked over weeks. The developed system offers the potential to study chronic impacts of drugs or genetic modifications on individual neurons in slice preparations over extended times.

  14. Nigrostriatal and Mesolimbic D2/3 Receptor Expression in Parkinson's Disease Patients with Compulsive Reward-Driven Behaviors.

    Science.gov (United States)

    Stark, Adam J; Smith, Christopher T; Lin, Ya-Chen; Petersen, Kalen J; Trujillo, Paula; van Wouwe, Nelleke C; Kang, Hakmook; Donahue, Manus J; Kessler, Robert M; Zald, David H; Claassen, Daniel O

    2018-03-28

    The nigrostriatal and mesocorticolimbic dopamine networks regulate reward-driven behavior. Regional alterations to mesolimbic dopamine D 2/3 receptor expression are described in drug-seeking and addiction disorders. Parkinson's disease (PD) patients are frequently prescribed D 2 -like dopamine agonist (DAgonist) therapy for motor symptoms, yet a proportion develop clinically significant behavioral addictions characterized by impulsive and compulsive behaviors (ICBs). Until now, changes in D 2/3 receptor binding in both striatal and extrastriatal regions have not been concurrently quantified in this population. We identified 35 human PD patients (both male and female) receiving DAgonist therapy, with ( n = 17) and without ( n = 18) ICBs, matched for age, disease duration, disease severity, and dose of dopamine therapy. In the off-dopamine state, all completed PET imaging with [ 18 F]fallypride, a high affinity D 2 -like receptor ligand that can measure striatal and extrastriatal D 2/3 nondisplaceable binding potential (BP ND ). Striatal differences between ICB+/ICB- patients localized to the ventral striatum and putamen, where ICB+ subjects had reduced BP ND In this group, self-reported severity of ICB symptoms positively correlated with midbrain D 2/3 receptor BP ND Group differences in regional D 2/3 BP ND relationships were also notable: ICB+ (but not ICB-) patients expressed positive correlations between midbrain and caudate, putamen, globus pallidus, and amygdala BP ND s. These findings support the hypothesis that compulsive behaviors in PD are associated with reduced ventral and dorsal striatal D 2/3 expression, similar to changes in comparable behavioral disorders. The data also suggest that relatively preserved ventral midbrain dopaminergic projections throughout nigrostriatal and mesolimbic networks are characteristic of ICB+ patients, and may account for differential DAgonist therapeutic response. SIGNIFICANCE STATEMENT The biologic determinants of

  15. Effects of endogenous pyrogen and prostaglandin E2 on hypothalamic neurons in rat brain slices.

    Science.gov (United States)

    Watanabe, T; Morimoto, A; Murakami, N

    1987-06-01

    We investigated the effects of endogenous pyrogen and prostaglandin E2 (PGE2) on the preoptic and anterior hypothalamic (POAH) neurons using brain slice preparations from the rat. Partially purified endogenous pyrogen did not change the activities of most of the neurons in the POAH region when applied locally through a micropipette attached to the recording electrode in proximity to the neurons. This indicates that partially purified endogenous pyrogen does not act directly on the neuronal activity in the POAH region. The partially purified endogenous pyrogen, applied into a culture chamber containing a brain slice, facilitated the activities in 24% of the total neurons tested, regardless of the thermal specificity of the neurons. Moreover, PGE2 added to the culture chamber facilitated 48% of the warm-responsive, 33% of the cold-responsive, and 29% of the thermally insensitive neurons. The direction of change in neuronal activity induced by partially purified endogenous pyrogen appears to be almost the same as that induced by PGE2 when these substances were applied by perfusion to the same neuron in the culture chamber. These results suggest that partially purified pyrogen applied to the perfusate of the culture chamber stimulates some constituents of brain tissue to synthesize and release prostaglandin, which in turn affects the neuronal activity of the POAH region.

  16. Integrating interface slicing into software engineering processes

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    Interface slicing is a tool which was developed to facilitate software engineering. As previously presented, it was described in terms of its techniques and mechanisms. The integration of interface slicing into specific software engineering activities is considered by discussing a number of potential applications of interface slicing. The applications discussed specifically address the problems, issues, or concerns raised in a previous project. Because a complete interface slicer is still under development, these applications must be phrased in future tenses. Nonetheless, the interface slicing techniques which were presented can be implemented using current compiler and static analysis technology. Whether implemented as a standalone tool or as a module in an integrated development or reverse engineering environment, they require analysis no more complex than that required for current system development environments. By contrast, conventional slicing is a methodology which, while showing much promise and intuitive appeal, has yet to be fully implemented in a production language environment despite 12 years of development.

  17. A survey of program slicing for software engineering

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    This research concerns program slicing which is used as a tool for program maintainence of software systems. Program slicing decreases the level of effort required to understand and maintain complex software systems. It was first designed as a debugging aid, but it has since been generalized into various tools and extended to include program comprehension, module cohesion estimation, requirements verification, dead code elimination, and maintainence of several software systems, including reverse engineering, parallelization, portability, and reuse component generation. This paper seeks to address and define terminology, theoretical concepts, program representation, different program graphs, developments in static slicing, dynamic slicing, and semantics and mathematical models. Applications for conventional slicing are presented, along with a prognosis of future work in this field.

  18. RF slice profile effects in magnetic resonance fingerprinting.

    Science.gov (United States)

    Hong, Taehwa; Han, Dongyeob; Kim, Min-Oh; Kim, Dong-Hyun

    2017-09-01

    The radio frequency (RF) slice profile effects on T1 and T2 estimation in magnetic resonance fingerprinting (MRF) are investigated with respect to time-bandwidth product (TBW), flip angle (FA) level and field inhomogeneities. Signal evolutions are generated incorporating the non-ideal slice selective excitation process using Bloch simulation and matched to the original dictionary with and without the non-ideal slice profile taken into account. For validation, phantom and in vivo experiments are performed at 3T. Both simulations and experiments results show that T1 and T2 error from non-ideal slice profile increases with increasing FA level, off-resonance, and low TBW values. Therefore, RF slice profile effects should be compensated for accurate determination of the MR parameters. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. NMR surprizes with thin slices and strong gradients

    Energy Technology Data Exchange (ETDEWEB)

    Gaedke, Achim; Kresse, Benjamin [Institute of Condensed Matter Physics, Technische Universitaet Darmstadt (Germany); Nestle, Nikolaus

    2008-07-01

    In the context of our work on diffusion-relaxation-coupling in thin excited slices, we perform NMR experiments in static magnetic field gradients up to 200 T/m. For slice thicknesses in the range of 10{mu}m, the frequency bandwidth of the excited slices becomes sufficiently narrow that free induction decays (FIDs) become observable despite the presence of the strong static gradient. The observed FIDs were also simulated using standard methods from MRI physics. Possible effects of diffusion during the FID duration are still minor at this slice thickness in water but might become dominant for smaller slices or more diffusive media. Furthermore, the detailed excitation structure of the RF pulses was studied in profiling experiments over the edge of a plane liquid cell. Side lobe effects to the slices will be discussed along with approaches to control them. The spatial resolution achieved in the profiling experiments furthermore allows the identification of thermal expansion phenomena in the NMR magnet. Measures to reduce the temperature drift problems are presented.

  20. Rosiglitazone Suppresses In Vitro Seizures in Hippocampal Slice by Inhibiting Presynaptic Glutamate Release in a Model of Temporal Lobe Epilepsy.

    Directory of Open Access Journals (Sweden)

    Shi-Bing Wong

    Full Text Available Peroxisomal proliferator-activated receptor gamma (PPARγ is a nuclear hormone receptor whose agonist, rosiglitazone has a neuroprotective effect to hippocampal neurons in pilocarpine-induced seizures. Hippocampal slice preparations treated in Mg2+ free medium can induce ictal and interictal-like epileptiform discharges, which is regarded as an in vitro model of N-methyl-D-aspartate (NMDA receptor-mediated temporal lobe epilepsy (TLE. We applied rosiglitazone in hippocampal slices treated in Mg2+ free medium. The effects of rosiglitazone on hippocampal CA1-Schaffer collateral synaptic transmission were tested. We also examined the neuroprotective effect of rosiglitazone toward NMDA excitotoxicity on cultured hippocampal slices. Application of 10 μM rosiglitazone significantly suppressed amplitude and frequency of epileptiform discharges in CA1 neurons. Pretreatment with the PPARγ antagonist GW9662 did not block the effect of rosiglitazone on suppressing discharge frequency, but reverse the effect on suppressing discharge amplitude. Application of rosiglitazone suppressed synaptic transmission in the CA1-Schaffer collateral pathway. By miniature excitatory-potential synaptic current (mEPSC analysis, rosiglitazone significantly suppressed presynaptic neurotransmitter release. This phenomenon can be reversed by pretreating PPARγ antagonist GW9662. Also, rosiglitazone protected cultured hippocampal slices from NMDA-induced excitotoxicity. The protective effect of 10 μM rosiglitazone was partially antagonized by concomitant high dose GW9662 treatment, indicating that this effect is partially mediated by PPARγ receptors. In conclusion, rosiglitazone suppressed NMDA receptor-mediated epileptiform discharges by inhibition of presynaptic neurotransmitter release. Rosiglitazone protected hippocampal slice from NMDA excitotoxicity partially by PPARγ activation. We suggest that rosiglitazone could be a potential agent to treat patients with TLE.

  1. Erythropoietin promotes oligodendrogenesis and myelin repair following lysolecithin-induced injury in spinal cord slice culture

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yun Kyung; Kim, Gunha; Park, Serah; Sim, Ju Hee; Won, You Jin [Department of Anatomy and Cell Biology, University of Ulsan College of Medicine, 388-1 Pungnap-dong, Songpa-gu, Seoul 138-736 (Korea, Republic of); Hwang, Chang Ho [Department of Physical Medicine and Rehabilitation, Ulsan University Hospital, University of Ulsan College of Medicine, 290-3 Jeonha-dong, Dong-gu, Ulsan 682-714 (Korea, Republic of); Yoo, Jong Yoon, E-mail: jyyoo@amc.seoul.kr [Department of Rehabilitation Medicine, University of Ulsan College of Medicine, 388-1 Pungnap-dong, Songpa-gu, Seoul 138-736 (Korea, Republic of); Hong, Hea Nam, E-mail: hnhong@amc.seoul.kr [Department of Anatomy and Cell Biology, University of Ulsan College of Medicine, 388-1 Pungnap-dong, Songpa-gu, Seoul 138-736 (Korea, Republic of)

    2012-01-13

    Highlights: Black-Right-Pointing-Pointer Lysolecithin-induced demyelination elevated EpoR expression in OPCs. Black-Right-Pointing-Pointer In association with elevated EpoR, EPO increased OPCs proliferation. Black-Right-Pointing-Pointer EPO enhanced the oligodendrogenesis via activation of JAK2 pathway. Black-Right-Pointing-Pointer EPO promoted myelin repair following lysolecithin-induced demyelination. -- Abstract: Here, we sought to delineate the effect of EPO on the remyelination processes using an in vitro model of demyelination. We report that lysolecithin-induced demyelination elevated EPO receptor (EpoR) expression in oligodendrocyte progenitor cells (OPCs), facilitating the beneficial effect of EPO on the formation of oligodendrocytes (oligodendrogenesis). In the absence of EPO, the resultant remyelination was insufficient, possibly due to a limiting number of oligodendrocytes rather than their progenitors, which proliferate in response to lysolecithin-induced injury. By EPO treatment, lysolecithin-induced proliferation of OPCs was accelerated and the number of myelinating oligodendrocytes and myelin recovery was increased. EPO also enhanced the differentiation of neural progenitor cells expressing EpoR at high level toward the oligodendrocyte-lineage cells through activation of cyclin E and Janus kinase 2 pathways. Induction of myelin-forming oligodendrocytes by high dose of EPO implies that EPO might be the key factor influencing the final differentiation of OPCs. Taken together, our data suggest that EPO treatment could be an effective way to enhance remyelination by promoting oligodendrogenesis in association with elevated EpoR expression in spinal cord slice culture after lysolecithin-induced demyelination.

  2. Chronic organic manganese administration in the rat does not damage dopaminergic nigrostriatal neurons.

    Science.gov (United States)

    Yong, V W; Perry, T L; Godolphin, W J; Jones, K A; Clavier, R M; Ito, M; Foulks, J G

    1986-01-01

    In an attempt to produce an animal model of Parkinson's disease, we injected rats repeatedly with high doses of methylcyclopentadienyl manganese tricarbonyl (MMT), a compound which has been reported to lower striatal dopamine content in mice. Chronic MMT administration for up to 5 months, even though it produced a substantial elevation in brain manganese content during the period of exposure, did not destroy dopaminergic nigrostriatal neurons. This was assessed by measurements of tyrosine hydroxylase activity and contents of dopamine and its metabolites in the striatum, and by histological examination of the substantia nigra. Our results differ from those of others who administered manganese chloride in drinking water to rats. This discrepancy is unlikely to be a consequence of differences in duration of exposure or route of administration. It could be due to our having used an organic rather than an inorganic manganese compound, or to a species difference in vulnerability to organic manganese between rats and mice.

  3. Thin slices of child personality: Perceptual, situational, and behavioral contributions.

    Science.gov (United States)

    Tackett, Jennifer L; Herzhoff, Kathrin; Kushner, Shauna C; Rule, Nicholas

    2016-01-01

    The present study examined whether thin-slice ratings of child personality serve as a resource-efficient and theoretically valid measurement of child personality traits. We extended theoretical work on the observability, perceptual accuracy, and situational consistency of childhood personality traits by examining intersource and interjudge agreement, cross-situational consistency, and convergent, divergent, and predictive validity of thin-slice ratings. Forty-five unacquainted independent coders rated 326 children's (ages 8-12) personality in 1 of 15 thin-slice behavioral scenarios (i.e., 3 raters per slice, for over 14,000 independent thin-slice ratings). Mothers, fathers, and children rated children's personality, psychopathology, and competence. We found robust evidence for correlations between thin-slice and mother/father ratings of child personality, within- and across-task consistency of thin-slice ratings, and convergent and divergent validity with psychopathology and competence. Surprisingly, thin-slice ratings were more consistent across situations in this child sample than previously found for adults. Taken together, these results suggest that thin slices are a valid and reliable measure to assess child personality, offering a useful method of measurement beyond questionnaires, helping to address novel questions of personality perception and consistency in childhood. (c) 2016 APA, all rights reserved).

  4. Nigrostriatal interaction in the aging brain: new therapeutic target for Parkinson's disease.

    Science.gov (United States)

    Błaszczyk, Janusz W

    2017-01-01

    Parkinson's disease (PD) is a progressive neurodegenerative disorder of unclear etiology and pathogenesis. Research results gathered to date support the hypothesis that the motor symptoms of the disease result from the gradual loss of midbrain dopamine neurons residing in the substantia nigra pars compacta (SNpc). Recent discoveries, however, significantly expand this knowledge indicating that the primary source of the PD pathogenesis may be located both in the SNpc as well as in the GABAergic striatum. Newly discovered striatal neurogenesis - normally a lifelong process - determines the efficiency of nigrostriatal interaction. Deficient neurogenesis within the striatum followed by a decline in the GABAergic/dopaminergic interaction results in progressive disconnection of the dopaminergic input, which initiates a 'vicious circle' cascade of neuronal damage. Effects of both deficient striatal neurogenesis and age-related neurodegeneration within the striatum accumulate, resulting in a progressive decline in the control functions of the basal ganglia, loss of dopaminergic neurons, and occurrence of PD clinical symptoms. Functional and pharmacological control of these dynamic relationships may result in treatments that are more effective with fewer side-effects.

  5. Slices

    KAUST Repository

    McCrae, James

    2011-01-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours of intersection of planes with a 3D object, for creating shape abstractions, motivated by their popularity in art and engineering. We first perform a user study to show that humans do define consistent and similar planar section proxies for common objects. Interestingly, we observe a strong correlation between user-defined planes and geometric features of objects. Further we show that the problem of finding the minimum set of planes that capture a set of 3D geometric shape features is both NP-hard and not always the proxy a user would pick. Guided by the principles inferred from our user study, we present an algorithm that progressively selects planes to maximize feature coverage, which in turn influence the selection of subsequent planes. The algorithmic framework easily incorporates various shape features, while their relative importance values are computed and validated from the user study data. We use our algorithm to compute planar slices for various objects, validate their utility towards object abstraction using a second user study, and conclude showing the potential applications of the extracted planar slice shape proxies. © 2011 ACM.

  6. Evaluation of nigrostriatal damage and its change over weeks in a rat model of Parkinson's disease: small animal positron emission tomography studies with [11C]β-CFT

    International Nuclear Information System (INIS)

    Liu Limin; Wang Yong; Li Bo; Jia Jun; Sun Zuoli; Zhang Jinming; Tian Jiahe; Wang Xiaomin

    2009-01-01

    Introduction: The cardinal pathological feature of Parkinson's disease (PD) is progressive loss of dopaminergic neurons. Since dopamine transporter (DAT) is a protein located presynaptically on dopaminergic nerve terminals, radioligands that bind to these sites are promising radiopharmaceuticals for evaluation of the integrity of the dopamine system. This study using positron emission tomography (PET) tracers, [ 11 C]-2β-carbomethoxy-3β-(4-fluorophenyl)-tropane ([ 11 C]β-CFT, radioligand for DAT), was aimed at evaluating the degree of nigrostriatal damage and its change over weeks in a rat model of PD. Methods: The brains of these rats were unilaterally lesioned by mechanical transection of the nigrostriatal dopamine pathway at the medial forebrain bundle (MFB). Behavioral studies were carried out by apomorphine (APO) challenge prior to and 1, 2 and 4 weeks after MFB axotomy. Small animal PET scans were performed 2 days after the behavioral test. Immunohistochemistry was conducted 4 days after the last PET scan. Results: Compared with the contralateral intact side, a progressively decreased [ 11 C]β-CFT binding was observed on the lesioned side which correlated inversely with the APO-induced rotations. Postmortem immunohistochemical studies confirmed the loss of both striatal dopamine fibers and nigral neurons on the lesioned side. Conclusion: These findings not only demonstrate that the neuronal degeneration in this model is relatively slow, but also suggest [ 11 C]β-CFT is a sensitive marker to monitor the degree of nigrostriatal damage and its change over weeks. This marker can be used prospectively to study the progression of the disease, thereby making detection of early phases of PD possible.

  7. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  8. Correlation of NTD-silicon rod and slice resistivity

    International Nuclear Information System (INIS)

    Wolverton, W.M.

    1984-01-01

    Neutron transmutation doped silicon is an electronic material which presents an opportunity to explore a high level of resistivity characterization. This is due to its excellent uniformity of dopant concentration. Appropriate resistivity measurements on the ingot raw material can be used as a predictor of slice resistivity. Correlation of finished NTD rod (i.e. ingot) resistivity to as-cut slice resistivity (after the sawing process) is addressed in the scope of this paper. Empirical data show that the shift of slice-center resistivity compared to rod-end center resistivity is a function of a new kind of rod radial-resistivity gradient. This function has two domains, and most rods are in domain ''A''. Correlating equations show how to significantly improve the prediction of slice resistivity of rods in domain ''A''. The new rod resistivity specifications have resulted in manufacturing economies in the production of NTD silicon slices

  9. Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography

    International Nuclear Information System (INIS)

    Hsieh Jiang

    2001-01-01

    Multislice computed tomography (MCT) is one of the recent technology advancements in CT. Compared to single slice CT, MCT significantly improves examination time, x-ray tube efficiency, and contrast material utilization. Although the scan mode of MCT is predominately helical, step-and-shoot (axial) scans continue to be an important part of routine clinical protocols. In this paper, we present a detailed investigation on the slice sensitivity profile (SSP) of MCT in the step-and-shoot mode. Our investigation shows that, unlike single slice CT, the SSP for MCT exhibits multiple peaks and valleys resulting from intercell gaps between detector rows. To fully understand the characteristics of the SSP, we developed an analytical model to predict the behavior of MCT. We propose a simple experimental technique that can quickly and accurately measure SSP. The impact of the SSP on image artifacts and low contrast detectability is also investigated

  10. Mathematical Modeling of Thin Layer Microwave Drying of Taro Slices

    Science.gov (United States)

    Kumar, Vivek; Sharma, H. K.; Singh, K.

    2016-03-01

    The present study investigated the drying kinetics of taro slices precooked in different medium viz water (WC), steam (SC) and Lemon Solution (LC) and dried at different microwave power 360, 540 and 720 W. Drying curves of all precooked slices at all microwave powers showed falling rate period along with a very short accelerating period at the beginning of the drying. At all microwave powers, higher drying rate was observed for LC slices as compared to WC and SC slices. To select a suitable drying curve, seven thin-layer drying models were fitted to the experimental data. The data revealed that the Page model was most adequate in describing the microwave drying behavior of taro slices precooked in different medium. The highest effective moisture diffusivity value of 2.11 × 10-8 m2/s was obtained for LC samples while the lowest 0.83 × 10-8 m2/s was obtained for WC taro slices. The activation energy (E a ) of LC taro slices was lower than the E a of WC and SC taro slices.

  11. Specific accumulation of 18F-deoxyglucose in three-dimensional long-term cultures of human and rodent brain tissue

    International Nuclear Information System (INIS)

    Hocke, C.; Prante, O.; Kuwert, T.; Bluemcke, I.; Jeske, I.; Romstoeck, J.; Stefan, H.

    2007-01-01

    Aim: Organotypic slice cultures (OSC) of human brain specimens represent an intriguing experimental model for translational studies addressing, e.g., stem cell transplantation in neurodegenerative diseases or targeting invasion by malignant glioma ex vivo. However, long-term viability and phenomena of structural reorganization of human OSC remain to be further characterized. Here, we report the use of 18 F-deoxyglucose (FDG) for evaluating the viability of brain slice preparations obtained either from postnatal rats or human hippocampal specimens. Methods: Anatomically well preserved human hippocampi obtained from epilepsy surgery and rat hippocampus slice cultures obtained from six day old Wistar rats were dissected into horizontal slices. The slices were incubated with FDG in phosphate buffered saline up to 1 h, either with or without supplementation of glucose at a concentration of 2.5 mg/ml. Radioactivity within the medium or slice cultures was measured using a gamma-counter. In addition, distribution of radioactivity was autoradiographically visualized and quantified as counts per mm 2 . Results: In rat hippocampal slices, FDG accumulated with 1 300 000 ± 68 000 counts/mm 2 , whereas the incorporation of the radioactive label in human slices was in the order of 1 500 000 ± 370 000 counts/mm 2 . The elevation of glucose concentration within the medium led to a significant three-fold decrease of FDG accumulation in rat slices and to a 2.4-fold decrease in human specimens. Conclusions: FDG accumulated in organotypic brain cultures of human or rodent origin. FDG is thus suited to investigate the viability of OSC. Furthermore, these preparations open new ways to study the factors governing cerebral FDG uptake in brain tissue ex vivo. (orig.)

  12. Effect of ghrelin on the motor deficit caused by the ablation of nigrostriatal dopaminergic cells or the inhibition of striatal dopamine receptors.

    Science.gov (United States)

    Suda, Yukari; Kuzumaki, Naoko; Narita, Michiko; Hamada, Yusuke; Shibasaki, Masahiro; Tanaka, Kenichi; Tamura, Hideki; Kawamura, Takashi; Kondo, Takashige; Yamanaka, Akihiro; Narita, Minoru

    2018-02-19

    Ghrelin plays roles in a wide range of central functions by activating the growth hormone secretagogue receptor (GHSR). This receptor has recently been found in the substantia nigra (SN) to control dopamine (DA)-related physiological functions. The dysregulation of DA neurons in the SN pars compacta (SNc) and the consequent depletion of striatal DA are known to underlie the motor deficits observed in Parkinson's disease (PD). In the present study, we further investigated the role of the SN-ghrelin system in motor function under the stereotaxic injection of AAV-CMV-FLEX-diphtheria toxin A (DTA) into the SN of dopamine transporter (DAT)-Cre (DAT SN ::DTA) mice to expunge DA neurons of the SNc. First, we confirmed the dominant expression of GHSR1a, which is a functional GHSR, in tyrosine hydroxylase (TH)-positive DA neurons in the SNc of control mice. In DAT SN ::DTA mice, we clearly observed motor dysfunction using several behavioral tests. An immunohistochemical study revealed a dramatic loss of TH-positive DA neurons in the SNc and DAT-labeled axon terminals in the striatum, and an absence of mRNAs for TH and DAT in the SN of DAT SN ::DTA mice. The mRNA level of GHSR1a was drastically decreased in the SN of these mice. In normal mice, we also found the mRNA expression of GHSR1a within GABAergic neurons in the SN pars reticulata (SNr). Under these conditions, a single injection of ghrelin into the SN failed to improve the motor deficits caused by ablation of the nigrostriatal DA network using DAT SN ::DTA mice, whereas intra-SN injection of ghrelin suppressed the motor dysfunction caused by the administration of haloperidol, which is associated with the transient inhibition of DA transmission. These findings suggest that phasic activation of the SNc-ghrelin system could improve the dysregulation of nigrostriatal DA transmission related to the initial stage of PD, but not the motor deficits under the depletion of nigrostriatal DA. Although GHSRs are found in non

  13. RETROSPECTIVE DETECTION OF INTERLEAVED SLICE ACQUISITION PARAMETERS FROM FMRI DATA

    Science.gov (United States)

    Parker, David; Rotival, Georges; Laine, Andrew; Razlighi, Qolamreza R.

    2015-01-01

    To minimize slice excitation leakage to adjacent slices, interleaved slice acquisition is nowadays performed regularly in fMRI scanners. In interleaved slice acquisition, the number of slices skipped between two consecutive slice acquisitions is often referred to as the ‘interleave parameter’; the loss of this parameter can be catastrophic for the analysis of fMRI data. In this article we present a method to retrospectively detect the interleave parameter and the axis in which it is applied. Our method relies on the smoothness of the temporal-distance correlation function, which becomes disrupted along the axis on which interleaved slice acquisition is applied. We examined this method on simulated and real data in the presence of fMRI artifacts such as physiological noise, motion, etc. We also examined the reliability of this method in detecting different types of interleave parameters and demonstrated an accuracy of about 94% in more than 1000 real fMRI scans. PMID:26161244

  14. Palmitoylethanolamide exerts neuroprotective effects in mixed neuroglial cultures and organotypic hippocampal slices via peroxisome proliferator-activated receptor-α

    Directory of Open Access Journals (Sweden)

    Scuderi Caterina

    2012-03-01

    Full Text Available Abstract Background In addition to cytotoxic mechanisms directly impacting neurons, β-amyloid (Aβ-induced glial activation also promotes release of proinflammatory molecules that may self-perpetuate reactive gliosis and damage neighbouring neurons, thus amplifying neuropathological lesions occurring in Alzheimer's disease (AD. Palmitoylethanolamide (PEA has been studied extensively for its anti-inflammatory, analgesic, antiepileptic and neuroprotective effects. PEA is a lipid messenger isolated from mammalian and vegetable tissues that mimics several endocannabinoid-driven actions, even though it does not bind to cannabinoid receptors. Some of its pharmacological properties are considered to be dependent on the expression of peroxisome proliferator-activated receptors-α (PPARα. Findings In the present study, we evaluated the effect of PEA on astrocyte activation and neuronal loss in models of Aβ neurotoxicity. To this purpose, primary rat mixed neuroglial co-cultures and organotypic hippocampal slices were challenged with Aβ1-42 and treated with PEA in the presence or absence of MK886 or GW9662, which are selective PPARα and PPARγ antagonists, respectively. The results indicate that PEA is able to blunt Aβ-induced astrocyte activation and, subsequently, to improve neuronal survival through selective PPARα activation. The data from organotypic cultures confirm that PEA anti-inflammatory properties implicate PPARα mediation and reveal that the reduction of reactive gliosis subsequently induces a marked rebound neuroprotective effect on neurons. Conclusions In line with our previous observations, the results of this study show that PEA treatment results in decreased numbers of infiltrating astrocytes during Aβ challenge, resulting in significant neuroprotection. PEA could thus represent a promising pharmacological tool because it is able to reduce Aβ-evoked neuroinflammation and attenuate its neurodegenerative consequences.

  15. Water-activity of dehydrated guava slices sweeteners

    International Nuclear Information System (INIS)

    Ayub, M.; Zeb, A.; Ullah, J.

    2005-01-01

    A study was carried out to investigate the individual and combined effect of caloric sweeteners (sucrose, glucose and fructose) and non-caloric sweeteners (saccharine, cyclamate and aspartame) along with antioxidants (citric acid and ascorbic acid) and chemical preservatives (potassium metabisulphite and potassium sorbate) on the water-activity (a/sub w/) of dehydrated guava slices. Different dilutions of caloric sweeteners (20, 30, 40 and 50 degree brix (bx) and non-caloric sweeteners (equivalent to sucrose sweetness) were used. Guava slices were osmotically dehydrated in these solutions and then dehydrated initially at 0 and then at 60 degree C to final moisture-content of 20-25%. Guava slices prepared with sucrose: glucose 7:3 potassium metabisulphite, ascorbic acid and citric acid produced best quality products, which have minimum (a/sub w/) and best overall sensory characteristics. The analysis showed that treatments and their various concentrations had a significant effect (p=0.05) on (a/sub w/) of dehydrated guava slices. (author)

  16. Interactive Slice of the CMS detector

    CERN Multimedia

    Davis, Siona Ruth

    2016-01-01

    This slice shows a colorful cross-section of the CMS detector with all parts of the detector labelled. Viewers are invited to click on buttons associated with five types of particles to see what happens when each type interacts with the sections of the detector. The five types of particles users can select to send through the slice are muons, electrons, neutral hadrons, charged hadrons and photons. Supplementary information on each type of particles is given. Useful for inclusion into general talks on CMS etc. *Animated CMS "slice" for Powerpoint (Mac & PC) Original version - 2004 Updated version - July 2010 *Six slides required - first is a set of buttons; others are for each particle type (muon, electron, charged/neutral hadron, photon) Recommend putting slide 1 anywhere in your presentation and the rest at the end

  17. Development of a bread slicing machine from locally sourced ...

    African Journals Online (AJOL)

    This paper presents the development of a bread slicing machine which is a mechanical device that is used for slicing bread instead of the crude cumbersome and unhygienic method of manual slicing of bread. In an attempt to facilitate the final processing of bread which is a common daily food requirement of most Nigerians ...

  18. Precision-cut liver slices as a model for the early onset of liver fibrosis to test antifibrotic drugs

    NARCIS (Netherlands)

    Westra, Inge M.; Oosterhuis, Dorenda; Groothuis, Geny M. M.; Olinga, Peter

    2014-01-01

    Induction of fibrosis during prolonged culture of precision-cut liver slices (PCLS) was reported. In this study, the use of rat PCLS was investigated to further characterize the mechanism of early onset of fibrosis in this model and the effects of antifibrotic compounds. Rat PCLS were incubated for

  19. Cardiac tissue slices: preparation, handling, and successful optical mapping.

    Science.gov (United States)

    Wang, Ken; Lee, Peter; Mirams, Gary R; Sarathchandra, Padmini; Borg, Thomas K; Gavaghan, David J; Kohl, Peter; Bollensdorff, Christian

    2015-05-01

    Cardiac tissue slices are becoming increasingly popular as a model system for cardiac electrophysiology and pharmacology research and development. Here, we describe in detail the preparation, handling, and optical mapping of transmembrane potential and intracellular free calcium concentration transients (CaT) in ventricular tissue slices from guinea pigs and rabbits. Slices cut in the epicardium-tangential plane contained well-aligned in-slice myocardial cell strands ("fibers") in subepicardial and midmyocardial sections. Cut with a high-precision slow-advancing microtome at a thickness of 350 to 400 μm, tissue slices preserved essential action potential (AP) properties of the precutting Langendorff-perfused heart. We identified the need for a postcutting recovery period of 36 min (guinea pig) and 63 min (rabbit) to reach 97.5% of final steady-state values for AP duration (APD) (identified by exponential fitting). There was no significant difference between the postcutting recovery dynamics in slices obtained using 2,3-butanedione 2-monoxime or blebistatin as electromechanical uncouplers during the cutting process. A rapid increase in APD, seen after cutting, was caused by exposure to ice-cold solution during the slicing procedure, not by tissue injury, differences in uncouplers, or pH-buffers (bicarbonate; HEPES). To characterize intrinsic patterns of CaT, AP, and conduction, a combination of multipoint and field stimulation should be used to avoid misinterpretation based on source-sink effects. In summary, we describe in detail the preparation, mapping, and data analysis approaches for reproducible cardiac tissue slice-based investigations into AP and CaT dynamics. Copyright © 2015 the American Physiological Society.

  20. Geometry Processing of Conventionally Produced Mouse Brain Slice Images.

    Science.gov (United States)

    Agarwal, Nitin; Xu, Xiangmin; Gopi, M

    2018-04-21

    Brain mapping research in most neuroanatomical laboratories relies on conventional processing techniques, which often introduce histological artifacts such as tissue tears and tissue loss. In this paper we present techniques and algorithms for automatic registration and 3D reconstruction of conventionally produced mouse brain slices in a standardized atlas space. This is achieved first by constructing a virtual 3D mouse brain model from annotated slices of Allen Reference Atlas (ARA). Virtual re-slicing of the reconstructed model generates ARA-based slice images corresponding to the microscopic images of histological brain sections. These image pairs are aligned using a geometric approach through contour images. Histological artifacts in the microscopic images are detected and removed using Constrained Delaunay Triangulation before performing global alignment. Finally, non-linear registration is performed by solving Laplace's equation with Dirichlet boundary conditions. Our methods provide significant improvements over previously reported registration techniques for the tested slices in 3D space, especially on slices with significant histological artifacts. Further, as one of the application we count the number of neurons in various anatomical regions using a dataset of 51 microscopic slices from a single mouse brain. To the best of our knowledge the presented work is the first that automatically registers both clean as well as highly damaged high-resolutions histological slices of mouse brain to a 3D annotated reference atlas space. This work represents a significant contribution to this subfield of neuroscience as it provides tools to neuroanatomist for analyzing and processing histological data. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Influence of γ-irradiation on drying of slice potato

    International Nuclear Information System (INIS)

    Wang Jun; Chao Yan; Fu Junjie; Wang Jianping

    2001-01-01

    A new technology is introduced to dry food products by hot-air after pretreated by irradiation. The influence of different dosage of irradiation, temperature of hot air, thickness of the slice potato on the rate of dehydration temperature of irradiated potato were studied. A conclusion is reached that the 3 factors, irradiation dosage, hot-air temperature and thickness of slice potato, affect the rate of dehydration and temperature of slice potato. The higher the dosage is, the greater the rate of dehydration of potato becomes, and the higher the temperature of the slice potato gets. (authors)

  2. Influence of the slice thickness in CT to clinical effect

    International Nuclear Information System (INIS)

    Kimura, Kazue; Katakura, Toshihiko; Ito, Masami; Okuaki, Okihisa; Suzuki, Kenji

    1980-01-01

    CT is a kind of tomography. Therefore, what thickness of tissue is being observed in the picture - this is important in the clinical application of CT. The influence of slice thickness on the pictures, especially its clinical effect, was examined. The apparatus used is EMI CT 5005. For varying the slice thickness, it cannot be any larger than the thickness essential to the apparatus. Therefore, to make it thinner than the essential 14 mm, collimators were specially prepared, which were used on the sides of an X-ray tube and a detector. As basic observation, the revelation ability of form owing to the difference of slice thickness using acryl pipes, and the revelation ability of slice face owing to the difference of slice thickness, were examined. About clinical observation, the results for certain cases of cancer were compared with the CT images for the slice thickness of 14 mm essential to EMI CT 5005 and the slice thickness of 7 mm achieved by means of the collimators. (J.P.N.)

  3. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-03-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  4. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-01-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  5. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  6. 123-I ioflupane (Datscan® presynaptic nigrostriatal imaging in patients with movement disorders

    Directory of Open Access Journals (Sweden)

    Angel Soriano Castrejón

    2005-10-01

    Full Text Available 123-I Ioflupane (Datscan® presynaptic imaging has been shown to have a significant utility in the assessment of patients with movement disorders 123-I Ioflupane SPECT is able to distinguish between Parkinson’s disease (PD and other forms of parkinsonism without degeneration of the nigrostriatal pathway, including a common movement disorder such as essential tremor, and to assess disease progression in PD and other neurodegenerative disorders involving the substantia nigra.A imagem pré-sináptica através de 123-I Ioflupane (Datscan® tem mostrado um papel significante na avaliação de pacientes com distúrbios do movimento. 123-I Ioflupane SPECT é capaz de distinguir entre Mal de Parkinson (MP e outras formas de parkinsonismo sem degenerações da via nigroestriatal incluindo um distúrbio comum de movimento parecido com o tremor essencial e para medir a evolução da doença no Mal de Parkinson e outros distúrbios neurodegenerativos envolvendo a substantia nigra.

  7. Alkaloid fraction of Uncaria rhynchophylla protects against N-methyl-D-aspartate-induced apoptosis in rat hippocampal slices.

    Science.gov (United States)

    Lee, Jongseok; Son, Dongwook; Lee, Pyeongjae; Kim, Sun-Yeou; Kim, Hocheol; Kim, Chang-Ju; Lim, Eunhee

    2003-09-04

    Uncaria rhynchophylla is a medicinal herb which has sedative and anticonvulsive effects and has been applied in the treatment of epilepsy in Oriental medicine. In this study, the effect of alkaloid fraction of U. rhynchophylla against N-methyl-D-aspartate (NMDA)-induced neuronal cell death was investigated. Pretreatment with an alkaloid fraction of U. rhynchophylla for 1 h decreased the degree of neuronal damage induced by NMDA exposure in cultured hippocampal slices and also inhibited NMDA-induced enhanced expressions of apoptosis-related genes such as c-jun, p53, and bax. In the present study, the alkaloid fraction of U. rhynchophylla was shown to have a protective property against NMDA-induced cytotoxicity by suppressing the NMDA-induced apoptosis in rat hippocampal slices.

  8. Introduction to bit slices and microprogramming

    International Nuclear Information System (INIS)

    Van Dam, A.

    1981-01-01

    Bit-slice logic blocks are fourth-generation LSI components which are natural extensions of traditional mulitplexers, registers, decoders, counters, ALUs, etc. Their functionality is controlled by microprogramming, typically to implement CPUs and peripheral controllers where both speed and easy programmability are required for flexibility, ease of implementation and debugging, etc. Processors built from bit-slice logic give the designer an alternative for approaching the programmibility of traditional fixed-instruction-set microprocessors with a speed closer to that of hardwired random logic. (orig.)

  9. Gravitational collapse of charged dust shell and maximal slicing condition

    International Nuclear Information System (INIS)

    Maeda, Keiichi

    1980-01-01

    The maximal slicing condition is a good time coordinate condition qualitatively when pursuing the gravitational collapse by the numerical calculation. The analytic solution of the gravitational collapse under the maximal slicing condition is given in the case of a spherical charged dust shell and the behavior of time slices with this coordinate condition is investigated. It is concluded that under the maximal slicing condition we can pursue the gravitational collapse until the radius of the shell decreases to about 0.7 x (the radius of the event horizon). (author)

  10. Preservation of low slice emittance in bunch compressors

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-03-01

    Full Text Available Minimizing the dilution of the electron beam emittance is crucial for the performance of accelerators, in particular for free electron laser facilities, where the length of the machine and the efficiency of the lasing process depend on it. Measurements performed at the SwissFEL Injector Test Facility revealed an increase in slice emittance after compressing the bunch even for moderate compression factors. The phenomenon was experimentally studied by characterizing the dependence of the effect on beam and machine parameters relevant for the bunch compression. The reproduction of these measurements in simulation required the use of a 3D beam dynamics model along the bunch compressor that includes coherent synchrotron radiation. Our investigations identified transverse effects, such as coherent synchrotron radiation and transverse space charge as the sources of the observed emittance dilution, excluding other effects, such as chromatic effects on single slices or spurious dispersion. We also present studies, both experimental and simulation based, on the effect of the optics mismatch of the slices on the variation of the slice emittance along the bunch. After a corresponding reoptimization of the beam optics in the test facility we reached slice emittances below 200 nm for the central slices along the longitudinal dimension with a moderate increase up to 300 nm in the head and tail for a compression factor of 7.5 and a bunch charge of 200 pC, equivalent to a final current of 150 A, at about 230 MeV energy.

  11. Nigrostriatal proteasome inhibition impairs dopamine neurotransmission and motor function in minipigs.

    Science.gov (United States)

    Lillethorup, Thea P; Glud, Andreas N; Alstrup, Aage K O; Mikkelsen, Trine W; Nielsen, Erik H; Zaer, Hamed; Doudet, Doris J; Brooks, David J; Sørensen, Jens Christian H; Orlowski, Dariusz; Landau, Anne M

    2018-05-01

    Parkinson's disease (PD) is characterized by degeneration of dopaminergic neurons in the substantia nigra leading to slowness and stiffness of limb movement with rest tremor. Using ubiquitin proteasome system inhibitors, rodent models have shown nigrostriatal degeneration and motor impairment. We translated this model to the Göttingen minipig by administering lactacystin into the medial forebrain bundle (MFB). Minipigs underwent positron emission tomography (PET) imaging with (+)-α-[ 11 C]dihydrotetrabenazine ([ 11 C]DTBZ), a marker of vesicular monoamine transporter 2 availability, at baseline and three weeks after the unilateral administration of 100 μg lactacystin into the MFB. Compared to their baseline values, minipigs injected with lactacystin showed on average a 36% decrease in ipsilateral striatal binding potential corresponding to impaired presynaptic dopamine terminals. Behaviourally, minipigs displayed asymmetrical motor disability with spontaneous rotations in one of the animals. Immunoreactivity for tyrosine hydroxylase (TH) and HLA-DR-positive microglia confirmed asymmetrical reduction in nigral TH-positive neurons with an inflammatory response in the lactacystin-injected minipigs. In conclusion, direct injection of lactacystin into the MFB of minipigs provides a model of PD with reduced dopamine neurotransmission, TH-positive neuron reduction, microglial activation and behavioural deficits. This large animal model could be useful in studies of symptomatic and neuroprotective therapies with translatability to human PD. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Targeting neurotransmitter receptors with nanoparticles in vivo allows single-molecule tracking in acute brain slices

    Science.gov (United States)

    Varela, Juan A.; Dupuis, Julien P.; Etchepare, Laetitia; Espana, Agnès; Cognet, Laurent; Groc, Laurent

    2016-03-01

    Single-molecule imaging has changed the way we understand many biological mechanisms, particularly in neurobiology, by shedding light on intricate molecular events down to the nanoscale. However, current single-molecule studies in neuroscience have been limited to cultured neurons or organotypic slices, leaving as an open question the existence of fast receptor diffusion in intact brain tissue. Here, for the first time, we targeted dopamine receptors in vivo with functionalized quantum dots and were able to perform single-molecule tracking in acute rat brain slices. We propose a novel delocalized and non-inflammatory way of delivering nanoparticles (NPs) in vivo to the brain, which allowed us to label and track genetically engineered surface dopamine receptors in neocortical neurons, revealing inherent behaviour and receptor activity regulations. We thus propose a NP-based platform for single-molecule studies in the living brain, opening new avenues of research in physiological and pathological animal models.

  13. Endogenous 24S-hydroxycholesterol modulates NMDAR-mediated function in hippocampal slices.

    Science.gov (United States)

    Sun, Min-Yu; Izumi, Yukitoshi; Benz, Ann; Zorumski, Charles F; Mennerick, Steven

    2016-03-01

    N-methyl-D-aspartate receptors (NMDARs), a major subtype of glutamate receptors mediating excitatory transmission throughout the central nervous system (CNS), play critical roles in governing brain function and cognition. Because NMDAR dysfunction contributes to the etiology of neurological and psychiatric disorders including stroke and schizophrenia, NMDAR modulators are potential drug candidates. Our group recently demonstrated that the major brain cholesterol metabolite, 24S-hydroxycholesterol (24S-HC), positively modulates NMDARs when exogenously administered. Here, we studied whether endogenous 24S-HC regulates NMDAR activity in hippocampal slices. In CYP46A1(-/-) (knockout; KO) slices where endogenous 24S-HC is greatly reduced, NMDAR tone, measured as NMDAR-to-α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor (AMPAR) excitatory postsynaptic current (EPSC) ratio, was reduced. This difference translated into more NMDAR-driven spiking in wild-type (WT) slices compared with KO slices. Application of SGE-301, a 24S-HC analog, had comparable potentiating effects on NMDAR EPSCs in both WT and KO slices, suggesting that endogenous 24S-HC does not saturate its NMDAR modulatory site in ex vivo slices. KO slices did not differ from WT slices in either spontaneous neurotransmission or in neuronal intrinsic excitability, and exhibited LTP indistinguishable from WT slices. However, KO slices exhibited higher resistance to persistent NMDAR-dependent depression of synaptic transmission induced by oxygen-glucose deprivation (OGD), an effect restored by SGE-301. Together, our results suggest that loss of positive NMDAR tone does not elicit compensatory changes in excitability or transmission, but it protects transmission against NMDAR-mediated dysfunction. We expect that manipulating this endogenous NMDAR modulator may offer new treatment strategies for neuropsychiatric dysfunction. Copyright © 2016 the American Physiological Society.

  14. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  15. Generalized Fourier slice theorem for cone-beam image reconstruction.

    Science.gov (United States)

    Zhao, Shuang-Ren; Jiang, Dazong; Yang, Kevin; Yang, Kang

    2015-01-01

    The cone-beam reconstruction theory has been proposed by Kirillov in 1961, Tuy in 1983, Feldkamp in 1984, Smith in 1985, Pierre Grangeat in 1990. The Fourier slice theorem is proposed by Bracewell 1956, which leads to the Fourier image reconstruction method for parallel-beam geometry. The Fourier slice theorem is extended to fan-beam geometry by Zhao in 1993 and 1995. By combining the above mentioned cone-beam image reconstruction theory and the above mentioned Fourier slice theory of fan-beam geometry, the Fourier slice theorem in cone-beam geometry is proposed by Zhao 1995 in short conference publication. This article offers the details of the derivation and implementation of this Fourier slice theorem for cone-beam geometry. Especially the problem of the reconstruction from Fourier domain has been overcome, which is that the value of in the origin of Fourier space is 0/0. The 0/0 type of limit is proper handled. As examples, the implementation results for the single circle and two perpendicular circle source orbits are shown. In the cone-beam reconstruction if a interpolation process is considered, the number of the calculations for the generalized Fourier slice theorem algorithm is O(N^4), which is close to the filtered back-projection method, here N is the image size of 1-dimension. However the interpolation process can be avoid, in that case the number of the calculations is O(N5).

  16. Improved biochemical preservation of lung slices during cold storage.

    Science.gov (United States)

    Bull, D A; Connors, R C; Reid, B B; Albanil, A; Stringham, J C; Karwande, S V

    2000-05-15

    Development of lung preservation solutions typically requires whole-organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that lung slices could be used to assess preservation of biochemical function during cold storage. Whole rat lungs were precision cut into slices with a thickness of 500 microm and preserved at 4 degrees C in the following solutions: University of Wisconsin (UW), Euro-Collins (EC), low-potassium-dextran (LPD), Kyoto (K), normal saline (NS), or a novel lung preservation solution (NPS) developed using this model. Lung biochemical function was assessed by ATP content (etamol ATP/mg wet wt) and capacity for protein synthesis (cpm/mg protein) immediately following slicing (0 h) and at 6, 12, 18, and 24 h of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as means +/- SD. ATP content was significantly higher in the lung slices stored in NPS compared with all other solutions at each time point (P cold storage. Copyright 2000 Academic Press.

  17. Continuous Slice Functional Calculus in Quaternionic Hilbert Spaces

    Science.gov (United States)

    Ghiloni, Riccardo; Moretti, Valter; Perotti, Alessandro

    2013-04-01

    The aim of this work is to define a continuous functional calculus in quaternionic Hilbert spaces, starting from basic issues regarding the notion of spherical spectrum of a normal operator. As properties of the spherical spectrum suggest, the class of continuous functions to consider in this setting is the one of slice quaternionic functions. Slice functions generalize the concept of slice regular function, which comprises power series with quaternionic coefficients on one side and that can be seen as an effective generalization to quaternions of holomorphic functions of one complex variable. The notion of slice function allows to introduce suitable classes of real, complex and quaternionic C*-algebras and to define, on each of these C*-algebras, a functional calculus for quaternionic normal operators. In particular, we establish several versions of the spectral map theorem. Some of the results are proved also for unbounded operators. However, the mentioned continuous functional calculi are defined only for bounded normal operators. Some comments on the physical significance of our work are included.

  18. Thermoluminescence results on slices from a Hiroshima tile UHFSFT03

    International Nuclear Information System (INIS)

    Stoneham, Doreen

    1987-01-01

    As was reported at the May 1984 Utah thermoluminescence (TL) workshop, high fired tiles and porcelain fragments can be sliced into 200 μm sections with constant surface area. When conventional pre-dose measurements were carried out on these slices the doses evaluated were in good agreement with results obtained by other workers using conventional quartz separation techniques. There are several advantages in using slices. First, less sample is needed as about 50 consecutive slices can be cut from a block measuring typically 1 cm 2 cross section and 2 cm in length. There are no problems with securing grains to the plate or loss of grains during measurement. Hypothetically there is less damage to the grains when they are cut slowly under cold water than when they are crushed. The disadvantage is that other minerals besides quartz are present in the slice and the signal is weaker than that obtained using quartz inclusions

  19. Modeling and Realization of a Bearingless Flux-Switching Slice Motor

    Directory of Open Access Journals (Sweden)

    Wolfgang Gruber

    2017-03-01

    Full Text Available This work introduces a novel bearingless slice motor design: the bearingless flux-switching slice motor. In contrast to state-of-the-art bearingless slice motors, the rotor in this new design does not include any permanent rotor magnets. This offers advantages for disposable devices, such as those used in the medical industry, and extends the range of bearingless slice motors toward high-temperature applications. In this study, our focus is on the analytical modeling of the suspension force torque generation of a single coil and the bearingless motor. We assessed motor performance in relation to motor topology by applying performance factors. A prototype motor was optimized, designed, and manufactured. We also presented the state-of-the-art nonlinear feedback control scheme used. The motor was operated, and both static and dynamic measurements were taken on a test bench, thus successfully demonstrating the functionality and applicability of the novel bearingless slice motor concept.

  20. Design and Development of a tomato Slicing Machine

    OpenAIRE

    Kamaldeen Oladimeji Salaudeen; Awagu E. F.

    2012-01-01

    Principle of slicing was reviewed and tomato slicing machine was developed based on appropriate technology. Locally available materials like wood, stainless steel and mild steel were used in the fabrication. The machine was made to cut tomatoes in 2cm thickness. The capacity of the machine is 540.09g per minute and its performance efficiency is 70%.

  1. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography

    International Nuclear Information System (INIS)

    Burgstahler, Christof; Reimann, Anja; Brodoefel, Harald; Tsiflikas, Ilias; Thomas, Christoph; Heuschmid, Martin; Daferner, Ulrike; Drosch, Tanja; Schroeder, Stephen; Herberts, Tina

    2009-01-01

    Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n=90; Siemens Sensation 64: n=91; Siemens Definition: n=75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347±13 vs. 254±14 (64-MSCT) vs. 233±11 (16-MSCT) HU], LM (362±11/275 ± 12/262±9), LAD (332±17/248±19/219±14) and LCX (310±12/210±13/221±10, all p<0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p<0.05). BMI had no impact on the CA ratio in DSCT only (p<0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a

  2. Ex vivo culture of patient tissue & examination of gene delivery.

    LENUS (Irish Health Repository)

    Rajendran, Simon

    2012-01-31

    This video describes the use of patient tissue as an ex vivo model for the study of gene delivery. Fresh patient tissue obtained at the time of surgery is sliced and maintained in culture. The ex vivo model system allows for the physical delivery of genes into intact patient tissue and gene expression is analysed by bioluminescence imaging using the IVIS detection system. The bioluminescent detection system demonstrates rapid and accurate quantification of gene expression within individual slices without the need for tissue sacrifice. This slice tissue culture system may be used in a variety of tissue types including normal and malignant tissue and allows us to study the effects of the heterogeneous nature of intact tissue and the high degree of variability between individual patients. This model system could be used in certain situations as an alternative to animal models and as a complementary preclinical mode prior to entering clinical trial.

  3. Characterization of the in vitro propagation of epileptiform electrophysiological activity in organotypic hippocampal slice cultures coupled to 3D microelectrode arrays.

    Science.gov (United States)

    Pisciotta, Marzia; Morgavi, Giovanna; Jahnsen, Henrik

    2010-10-28

    Dynamic aspects of the propagation of epileptiform activity have so far received little attention. With the aim of providing new insights about the spatial features of the propagation of epileptic seizures in the nervous system, we studied in vitro the initiation and propagation of traveling epileptiform waves of electrophysiological activity in the hippocampus by means of substrate three-dimensional microelectrode arrays (MEAs) for extracellular measurements. Pharmacologically disinhibited hippocampal slices spontaneously generate epileptiform bursts mostly originating in CA3 and propagating to CA1. Our study specifically addressed the activity-dependent changes of the propagation of traveling electrophysiological waves in organotypic hippocampal slices during epileptiform discharge and in particular our question is: what happens to the epileptic signals during their propagation through the slice? Multichannel data analysis enabled us to quantify an activity-dependent increase in the propagation velocity of spontaneous bursts. Moreover, through the evaluation of the coherence of the signals, it was possible to point out that only the lower-frequency components (propagation of electrophysiological activity becomes ineffective for those firing rates exceeding an upper bound or that some noise of neuronal origin was added to the signal during propagation. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Improved biochemical preservation of heart slices during cold storage.

    Science.gov (United States)

    Bull, D A; Reid, B B; Connors, R C; Albanil, A; Stringham, J C; Karwande, S V

    2000-01-01

    Development of myocardial preservation solutions requires the use of whole organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that myocardial slices could be used to assess preservation of biochemical function during cold storage. Whole rat hearts were precision cut into slices with a thickness of 200 microm and preserved at 4 degrees C in one of the following solutions: Columbia University (CU), University of Wisconsin (UW), D5 0.2% normal saline with 20 meq/l KCL (QNS), normal saline (NS), or a novel cardiac preservation solution (NPS) developed using this model. Myocardial biochemical function was assessed by ATP content (etamoles ATP/mg wet weight) and capacity for protein synthesis (counts per minute (cpm)/mg protein) immediately following slicing (0 hours), and at 6, 12, 18, and 24 hours of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as the mean +/- standard deviation. ATP content was higher in the heart slices stored in the NPS compared to all other solutions at 6, 12, 18 and 24 hours of cold storage (p cold storage (p cold storage.

  5. Incubation of curing brines for the production of ready-to-eat, uncured, no-nitrite-or-nitrate-added, ground, cooked and sliced ham.

    Science.gov (United States)

    Krause, B L; Sebranek, J G; Rust, R E; Mendonca, A

    2011-12-01

    Salt concentration, vegetable juice powder (VJP) concentration and temperature were investigated to determine necessary conditions for incubation of curing brines including VJP and a starter culture containing Staphylococcus carnosus prior to production of naturally cured, no-nitrate/nitrite-added meat products. Subsequently, incubated brines were utilized to produce no-nitrate/nitrite-added sliced ham in which quality characteristics and residual nitrite concentrations were measured to determine feasibility of brine incubation for nitrate conversion prior to injection. Two ham treatments (one with VJP and starter culture; one with pre-converted VJP) and a nitrite-added control were used. No differences (P>0.05) were found for color in the VJP treatments. Control sliced ham was redder after 42 days of storage, retaining significantly (Phams during the first week of storage. While the nitrite-added control retained greater red color and initially had more residual nitrite than the VJP treatments, the two VJP treatments did not differ from each other. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Pyrethroid insecticides evoke neurotransmitter release from rabbit striatal slices

    International Nuclear Information System (INIS)

    Eells, J.T.; Dubocovich, M.L.

    1988-01-01

    The effects of the synthetic pyrethroid insecticide fenvalerate ([R,S]-alpha-cyano-3-phenoxybenzyl[R,S]-2-(4-chlorophenyl)-3- methylbutyrate) on neurotransmitter release in rabbit brain slices were investigated. Fenvalerate evoked a calcium-dependent release of [ 3 H]dopamine and [ 3 H]acetylcholine from rabbit striatal slices that was concentration-dependent and specific for the toxic stereoisomer of the insecticide. The release of [ 3 H]dopamine and [ 3 H]acetylcholine by fenvalerate was modulated by D2 dopamine receptor activation and antagonized completely by the sodium channel blocker, tetrodotoxin. These findings are consistent with an action of fenvalerate on the voltage-dependent sodium channels of the presynaptic membrane resulting in membrane depolarization, and the release of dopamine and acetylcholine by a calcium-dependent exocytotic process. In contrast to results obtained in striatal slices, fenvalerate did not elicit the release of [ 3 H]norepinephrine or [ 3 H]acetylcholine from rabbit hippocampal slices indicative of regional differences in sensitivity to type II pyrethroid actions

  7. Overexpression of parkin in rat nigrostriatal dopamine system protects against methamphetamine neurotoxicity

    Science.gov (United States)

    Liu, Bin; Traini, Roberta; Killinger, Bryan; Schneider, Bernard; Moszczynska, Anna

    2013-01-01

    Methamphetamine (METH) is a central nervous system psychostimulant with a high potential for abuse. At high doses, METH causes a selective degeneration of dopaminergic terminals in the striatum, sparing other striatal terminals and cell bodies. We previously detected a deficit in parkin after binge METH in rat striatal synaptosomes. Parkin is an ubiquitin-protein E3 ligase capable of protecting dopamine neurons from diverse cellular insults. Whether the deficit in parkin mediates the toxicity of METH and whether parkin can protect from toxicity of the drug is unknown. The present study investigated whether overexpression of parkin attenuates degeneration of striatal dopaminergic terminals exposed to binge METH. Parkin overexpression in rat nigrostriatal dopamine system was achieved by microinjection of adeno-associated viral transfer vector 2/6 encoding rat parkin (AAV2/6-parkin) into the substantia nigra pars compacta. The microinjections of AAV2/6-parkin dose-dependently increased parkin levels in both the substantia nigra pars compacta and striatum. The levels of dopamine synthesizing enzyme, tyrosine hydroxylase, remained at the control levels; therefore, tyrosine hydroxylase immunoreactivity was used as an index of dopaminergic terminal integrity. In METH-exposed rats, the increase in parkin levels attenuated METH-induced decreases in striatal tyrosine hydroxylase immunoreactivity in a dose-dependent manner, indicating that parkin can protect striatal dopaminergic terminals against METH neurotoxicity. PMID:23313192

  8. Resource slicing in virtual wireless networks: a survey

    OpenAIRE

    Richart, Matias; Baliosian De Lazzari, Javier Ernesto; Serrat Fernández, Juan; Gorricho Moreno, Juan Luis

    2016-01-01

    New architectural and design approaches for radio access networks have appeared with the introduction of network virtualization in the wireless domain. One of these approaches splits the wireless network infrastructure into isolated virtual slices under their own management, requirements, and characteristics. Despite the advances in wireless virtualization, there are still many open issues regarding the resource allocation and isolation of wireless slices. Because of the dynamics and share...

  9. Verification-Driven Slicing of UML/OCL Models

    DEFF Research Database (Denmark)

    Shaikh, Asadullah; Clarisó Viladrosa, Robert; Wiil, Uffe Kock

    2010-01-01

    computational complexity can limit their scalability. In this paper, we consider a specific static model (UML class diagrams annotated with unrestricted OCL constraints) and a specific property to verify (satisfiability, i.e., “is it possible to create objects without violating any constraint?”). Current...... approaches to this problem have an exponential worst-case runtime. We propose a technique to improve their scalability by partitioning the original model into submodels (slices) which can be verified independently and where irrelevant information has been abstracted. The definition of the slicing procedure...

  10. Slice through an LHC bending magnet

    CERN Multimedia

    Slice through an LHC superconducting dipole (bending) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. There are 1232 15m long dipole magnets in the LHC.

  11. Preparation of positional renal slices for study of cell-specific toxicity.

    Science.gov (United States)

    Ruegg, C E; Gandolfi, A J; Nagle, R B; Krumdieck, C L; Brendel, K

    1987-04-01

    To reduce structural complexity, rabbit kidneys were sliced perpendicular to their cortical-papillary axis to isolate four distinct cell groupings. This positional orientation allows identification of each renal cell type based on its location within the slice. A mechanical slicer was used to make several precision-cut slices rapidly from an oriented cylindrical core of renal tissue, with minimal tissue trauma. Slices were then submerged under a gently circulating oxygenated media in a fritted glass support system that maintains viability (intracellular K+/DNA ratio) and structural integrity (histology) for at least 30 h. A high dose of mercuric chloride (10(-3) M) was used to demonstrate the structural and biochemical changes of intoxicated slices. This method provides a controlled subchronic in vitro system for the study of the individual cell types involved in cell-specific renal toxicities and may also be a useful tool for addressing other pharmacological and physiological research questions.

  12. An overview of 5G network slicing architecture

    Science.gov (United States)

    Chen, Qiang; Wang, Xiaolei; Lv, Yingying

    2018-05-01

    With the development of mobile communication technology, the traditional single network model has been unable to meet the needs of users, and the demand for differentiated services is increasing. In order to solve this problem, the fifth generation of mobile communication technology came into being, and as one of the key technologies of 5G, network slice is the core technology of network virtualization and software defined network, enabling network slices to flexibly provide one or more network services according to users' needs[1]. Each slice can independently tailor the network functions according to the requirements of the business scene and the traffic model and manage the layout of the corresponding network resources, to improve the flexibility of network services and the utilization of resources, and enhance the robustness and reliability of the whole network [2].

  13. A novel lung slice system with compromised antioxidant defenses

    Energy Technology Data Exchange (ETDEWEB)

    Hardwick, S.J.; Adam, A.; Cohen, G.M. (Univ. of London (England)); Smith, L.L. (Imperial Chemical Industries PLC, Cheshire (England))

    1990-04-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 {mu}M) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP{sup +}, and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of {sup 14}CO{sub 2} from D-({sup 14}C(U))-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone.

  14. A novel lung slice system with compromised antioxidant defenses

    International Nuclear Information System (INIS)

    Hardwick, S.J.; Adam, A.; Cohen, G.M.; Smith, L.L.

    1990-01-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 μM) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP + , and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of 14 CO 2 from D-[ 14 C(U)]-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone

  15. Development of striatal patch/matrix organization in organotypic co-cultures of perinatal striatum, cortex and substantia nigra.

    Science.gov (United States)

    Snyder-Keller, A; Costantini, L C; Graber, D J

    2001-01-01

    Organotypic cultures of fetal or early postnatal striatum were used to assess striatal patch formation and maintenance in the presence or absence of dopaminergic and glutamatergic influences. Vibratome-cut slices of the striatum prepared from embryonic day 19 to postnatal day 4 rat pups were maintained in static culture on clear membrane inserts in Dulbecco's modified Eagle's medium/F12 (1:1) with 20% horse serum. Some were co-cultured with embryonic day 12-16 ventral mesencephalon and/or embryonic day 19 to postnatal day 4 cortex, which produced a dense dopaminergic innervation and a modest cortical innervation. Donors of striatal and cortical tissue were previously injected with bromo-deoxyuridine (BrdU) on embryonic days 13 and 14 in order to label striatal neurons destined to populate the patch compartment of the striatum. Patches of BrdU-immunoreactive cells were maintained in organotypic cultures of late prenatal (embryonic days 20-22) or early postnatal striatum in the absence of nigral dopaminergic or cortical glutamatergic influences. In slices taken from embryonic day 19 fetuses prior to the time of in vivo patch formation, patches were observed to form after 10 days in vitro, in 39% of nigral-striatal co-cultures compared to 6% of striatal slices cultured alone or in the presence of cortex only. Patches of dopaminergic fibers, revealed by tyrosine hydroxylase immunoreactivity, were observed in the majority of nigral-striatal co-cultures. Immunostaining for the AMPA-type glutamate receptor GluR1 revealed a dense patch distribution in nearly all cultures, which developed in embryonic day 19 cultures after at least six days in vitro. These findings indicate that striatal patch/matrix organization is maintained in organotypic culture, and can be induced to form in vitro in striatal slices removed from fetuses prior to the time of in vivo patch formation. Furthermore, dopaminergic innervation from co-cultured pieces of ventral mesencephalon enhances patch

  16. Equilibrium initial data for moving puncture simulations: the stationary 1 + log slicing

    International Nuclear Information System (INIS)

    Baumgarte, T W; Matera, K; Etienne, Z B; Liu, Y T; Shapiro, S L; Taniguchi, K; Murchadha, N O

    2009-01-01

    We discuss a 'stationary 1 + log' slicing condition for the construction of solutions to Einstein's constraint equations. For stationary spacetimes, these initial data give a stationary foliation when evolved with 'moving puncture' gauge conditions that are often used in black hole evolutions. The resulting slicing is time independent and agrees with the slicing generated by being dragged along a timelike Killing vector of the spacetime. When these initial data are evolved with moving puncture gauge conditions, numerical errors arising from coordinate evolution should be minimized. While these properties appear very promising, suggesting that this slicing condition should be an attractive alternative to, for example, maximal slicing, we demonstrate in this paper that solutions can be constructed only for a small class of problems. For binary black hole initial data, in particular, it is often assumed that there exists an approximate helical Killing vector that generates the binary's orbit. We show that 1 + log slices that are stationary with respect to such a helical Killing vector cannot be asymptotically flat, unless the spacetime possesses an additional axial Killing vector.

  17. Electron slicing for the generation of tunable femtosecond soft x-ray pulses from a free electron laser and slice diagnostics

    Directory of Open Access Journals (Sweden)

    S. Di Mitri

    2013-04-01

    Full Text Available We present the experimental results of femtosecond slicing an ultrarelativistic, high brightness electron beam with a collimator. In contrast to some qualitative considerations reported in Phys. Rev. Lett. 92, 074801 (2004PRLTAO0031-900710.1103/PhysRevLett.92.074801, we first demonstrate that the collimation process preserves the slice beam quality, in agreement with our theoretical expectations, and that the collimation is compatible with the operation of a linear accelerator in terms of beam transport, radiation dose, and collimator heating. Accordingly, the collimated beam can be used for the generation of stable femtosecond soft x-ray pulses of tunable duration, from either a self-amplified spontaneous emission or an externally seeded free electron laser. The proposed method also turns out to be a more compact and cheaper solution for electron slice diagnostics than the commonly used radio frequency deflecting cavities and has minimal impact on the machine design.

  18. (Non)perturbative gravity, nonlocality, and nice slices

    International Nuclear Information System (INIS)

    Giddings, Steven B.

    2006-01-01

    Perturbative dynamics of gravity is investigated for high-energy scattering and in black hole backgrounds. In the latter case, a straightforward perturbative analysis fails, in a close parallel to the failure of the former when the impact parameter reaches the Schwarzschild radius. This suggests a flaw in a semiclassical description of physics on spatial slices that intersect both outgoing Hawking radiation and matter that has carried information into a black hole; such slices are instrumental in a general argument for black hole information loss. This indicates a possible role for the proposal that nonperturbative gravitational physics is intrinsically nonlocal

  19. The clinical efficacy of 1 mm-slice CT of the middle ear

    International Nuclear Information System (INIS)

    Noda, Kazuhiro; Noiri, Teruhisa; Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-01-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  20. The clinical efficacy of 1 mm-slice CT of the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Noda, Kazuhiro; Noiri, Teruhisa [Kawanishi Municipal Hospital, Hyogo (Japan); Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-02-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  1. Slice through an LHC focusing magnet

    CERN Multimedia

    Slice through an LHC superconducting quadrupole (focusing) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. Bringing beams into collision requires a precision comparable to making two knitting needles collide, launched from either side of the Atlantic Ocean.

  2. Feasibility study of 2D thick-slice MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Takeuchi, Miho; Higashimura, Kyouji; Komuro, Hiroyuki

    2000-01-01

    Conditions required to perform contrast MR digital subtraction angiography using a two-dimensional thick-slice high-speed gradient echo were investigated. The conditions in the phantom experiment included: slice profile, flip angle, imaging matrix, fat suppression, duration of IR pulse and frequency selectivity, flip angle of IR pulse and inversion time. Based on the results of the experiment, 2D thick-slice MRDSA was performed in volunteers. Under TR/TE=5.3-9/1.3-1.8 ms conditions, the requirements were a slice thick enough to include the target region, a flip angle of 10 degrees, and a phase matrix of 96 or more. Fat suppression was required for adipose-tissue-rich regions, such as the abdomen. The optimal conditions for applying the IR preparation pulse of the IR prepped fast gradient recalled echo as spectrally selective inversion recovery appeared to be: duration of IR pulse =20 ms, flip angle =100 degrees, and inversion time =40 ms. The authors concluded that it was feasible to perform 2D thick-slice MRDSA with time resolution within 1 second. (K.H.)

  3. Free-breathing cardiac MR stress perfusion with real-time slice tracking.

    Science.gov (United States)

    Basha, Tamer A; Roujol, Sébastien; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza

    2014-09-01

    To develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise. We propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence. The proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy. The proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans. Copyright © 2013 Wiley Periodicals, Inc.

  4. Study of Energy Consumption of Potato Slices During Drying Process

    Directory of Open Access Journals (Sweden)

    Hafezi Negar

    2015-06-01

    Full Text Available One of the new methods of food drying using infrared heating under vacuum is to increase the drying rate and maintain the quality of dried product. In this study, potato slices were dried using vacuum-infrared drying. Experiments were performed with the infrared lamp power levels 100, 150 and 200 W, absolute pressure levels 20, 80, 140 and 760 mmHg, and with three thicknesses of slices 1, 2 and 3 mm, in three repetitions. The results showed that the infrared lamp power, absolute pressure and slice thickness have important effects on the drying of potato. With increasing the radiation power, reducing the absolute pressure (acts of vacuum in the dryer chamber and also reducing the thickness of potato slices, drying time and the amount of energy consumed is reduced. In relation to thermal utilization efficiency, results indicated that with increasing the infrared radiation power and decreasing the absolute pressure, thermal efficiency increased.

  5. Lipopolysaccharide-induced dopaminergic cell death in rat midbrain slice cultures: role of inducible nitric oxide synthase and protection by indomethacin.

    Science.gov (United States)

    Shibata, Haruki; Katsuki, Hiroshi; Nishiwaki, Mayumi; Kume, Toshiaki; Kaneko, Shuji; Akaike, Akinori

    2003-09-01

    Glial cell activation associated with inflammatory reaction may contribute to pathogenic processes of neurodegenerative disorders, through production of several cytotoxic molecules. We investigated the consequences of glial activation by interferon-gamma (IFN-gamma)/lipopolysaccharide (LPS) in rat midbrain slice cultures. Application of IFN-gamma followed by LPS caused dopaminergic cell death and accompanying increases in nitrite production and lactate dehydrogenase release. Aminoguanidine, an inhibitor of inducible nitric oxide synthase (iNOS), or SB203580, an inhibitor of p38 mitogen-activated protein kinase, prevented dopaminergic cell loss as well as nitrite production. SB203580 also suppressed expression of iNOS and cyclooxygenase-2 (COX-2) induced by IFN-gamma/LPS. A COX inhibitor indomethacin protected dopaminergic neurons from IFN-gamma/LPS-induced injury, whereas selective COX-2 inhibitors such as NS-398 and nimesulide did not. Notably, indomethacin was able to attenuate neurotoxicity of a nitric oxide (NO) donor. Neutralizing antibodies against tumour necrosis factor-alpha and interleukin-1beta did not inhibit dopaminergic cell death caused by IFN-gamma/LPS, although combined application of these antibodies blocked lactate dehydrogenase release and decrease in the number of non-dopaminergic neurons. These results indicate that iNOS-derived NO plays a crucial role in IFN-gamma/LPS-induced dopaminergic cell death, and that indomethacin exerts protective effect by mechanisms probably related to NO neurotoxicity rather than through COX inhibition.

  6. Minocycline Has Anti-inflammatory Effects and Reduces Cytotoxicity in an Ex Vivo Spinal Cord Slice Culture Model of West Nile Virus Infection.

    Science.gov (United States)

    Quick, Eamon D; Seitz, Scott; Clarke, Penny; Tyler, Kenneth L

    2017-11-15

    West Nile virus (WNV) is a neurotropic flavivirus that can cause significant neurological disease. Mouse models of WNV infection demonstrate that a proinflammatory environment is induced within the central nervous system (CNS) after WNV infection, leading to entry of activated peripheral immune cells. We utilized ex vivo spinal cord slice cultures (SCSC) to demonstrate that anti-inflammatory mechanisms may also play a role in WNV-induced pathology and/or recovery. Microglia are a type of macrophage that function as resident CNS immune cells. Similar to mouse models, infection of SCSC with WNV induces the upregulation of proinflammatory genes and proteins that are associated with microglial activation, including the microglial activation marker Iba1 and CC motif chemokines CCL2, CCL3, and CCL5. This suggests that microglia assume a proinflammatory phenotype in response to WNV infection similar to the proinflammatory (M1) activation that can be displayed by other macrophages. We now show that the WNV-induced expression of these and other proinflammatory genes was significantly decreased in the presence of minocycline, which has antineuroinflammatory properties, including the ability to inhibit proinflammatory microglial responses. Minocycline also caused a significant increase in the expression of anti-inflammatory genes associated with alternative anti-inflammatory (M2) macrophage activation, including interleukin 4 (IL-4), IL-13, and FIZZ1. Minocycline-dependent alterations to M1/M2 gene expression were associated with a significant increase in survival of neurons, microglia, and astrocytes in WNV-infected slices and markedly decreased levels of inducible nitric oxide synthase (iNOS). These results demonstrate that an anti-inflammatory environment induced by minocycline reduces viral cytotoxicity during WNV infection in ex vivo CNS tissue. IMPORTANCE West Nile virus (WNV) causes substantial morbidity and mortality, with no specific therapeutic treatments available

  7. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  8. The visibility of mandibular canal on orthoradial and oblique CBCT slices at molar implant sites

    International Nuclear Information System (INIS)

    Alkhader, Mustafa; Jarab, Fadi; Shaweesh, Ashraf; Hudieb, Malik

    2016-01-01

    The aim of the present study was to compare visibility of the mandibular canal on cone beam computed tomography (CBCT)-based orthoradial and oblique slices at molar implant sites. CBCT images for 132 mandibular molar implant sites were selected for the study. After generating orthoradial and oblique slices, two observers evaluated the visibility of the mandibular canal using three-point scoring scale (1-3, good to excellent). Wilcoxon signed-rank test compared the visibility scores of the two slices. Both orthoradial and oblique slices obtained from CBCT had only very good to excellent mandibular canal visibility scores. At 114 mandibular molar implant sites, the visibility score was equal on both orthoradial and oblique slices. Although the visibility score was higher on orthoradial slices for 12 implant sites, the visibility score was higher for six implant sites on oblique slices and the difference was not significant. Therefore, the visibility of the mandibular canal was excellent and comparable on most of orthoradial and oblique slices obtained from CBCT images

  9. Extracellular Zn2+ Influx into Nigral Dopaminergic Neurons Plays a Key Role for Pathogenesis of 6-Hydroxydopamine-Induced Parkinson's Disease in Rats.

    Science.gov (United States)

    Tamano, Haruna; Nishio, Ryusuke; Morioka, Hiroki; Takeda, Atsushi

    2018-04-29

    Parkinson's disease (PD) is a progressive neurological disease characterized by a selective loss of nigrostriatal dopaminergic neurons. The exact cause of the neuronal loss remains unclear. Here, we report a unique mechanism of nigrostriatal dopaminergic neurodegeneration, in which extracellular Zn 2+ influx plays a key role for PD pathogenesis induced with 6-hydroxydopamine (6-OHDA) in rats. 6-OHDA rapidly increased intracellular Zn 2+ only in the substantia nigra pars compacta (SNpc) of brain slices and this increase was blocked in the presence of CaEDTA, an extracellular Zn 2+ chelator, and 6-cyano-7-nitroquinoxaline-2,3-dione (CNQX), an α-amino-3-hydroxy-5-methyl-4-isoxazolepropionate (AMPA) receptor antagonist, indicating that 6-OHDA rapidly increases extracellular Zn 2+ influx via AMPA receptor activation in the SNpc. Extracellular Zn 2+ concentration was decreased under in vivo SNpc perfusion with 6-OHDA and this decrease was blocked by co-perfusion with CNQX, supporting 6-OHDA-induced Zn 2+ influx via AMPA receptor activation in the SNpc. Interestingly, both 6-OHDA-induced loss of nigrostriatal dopaminergic neurons and turning behavior to apomorphine were ameliorated by co-injection of intracellular Zn 2+ chelators, i.e., ZnAF-2DA and N,N,N',N'-Tetrakis(2-pyridylmethyl)ethylenediamine (TPEN). Co-injection of TPEN into the SNpc blocked 6-OHDA-induced increase in intracellular Zn 2+ but not in intracellular Ca 2+ . These results suggest that the rapid influx of extracellular Zn 2+ into dopaminergic neurons via AMPA receptor activation in the SNpc induces nigrostriatal dopaminergic neurodegeneration, resulting in 6-OHDA-induced PD in rats.

  10. Magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere

    Science.gov (United States)

    Nursalim, Rahmat; Widodo, Basuki; Imron, Chairul

    2017-10-01

    Magnetohydrodynamics (MHD) is important study in engineering and industrial fields. By study on MHD, we can reach the fluid flow characteristics that can be used to minimize its negative effect to an object. In decades, MHD has been widely studied in various geometry forms and fluid types. The sliced sphere is a geometry form that has not been investigated. In this paper we study magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere. Assumed that the fluid is incompressible, there is no magnetic field, there is no electrical voltage, the sliced sphere is fix and there is no barrier around the object. In this paper we focus on velocity profile at stagnation point (x = 0°). Mathematical model is governed by continuity and momentum equation. It is converted to non-dimensional, stream function, and similarity equation. Solution of the mathematical model is obtained by using Keller-Box numerical method. By giving various of slicing angle and various of magnetic parameter we get the simulation results. The simulation results show that increasing the slicing angle causes the velocity profile be steeper. Also, increasing the value of magnetic parameter causes the velocity profile be steeper. On the large slicing angle there is no significant effect of magnetic parameter to velocity profile, and on the high the value of magnetic parameter there is no significant effect of slicing angle to velocity profile.

  11. On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT

    International Nuclear Information System (INIS)

    Flohr, T.; Ohnesorge, B.; Stierstorfer, K.

    2005-01-01

    The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging [de

  12. [Standardization of production of process Notopterygii Rhizoma et Radix slices].

    Science.gov (United States)

    Sun, Zhen-Yang; Wang, Ying-Zi; Nie, Rui-Jie; Zhang, Jing-Zhen; Wang, Si-Yu

    2017-12-01

    Notopterol, isoimperatorin, volatile oil and extract (water and ethanol) were used as the research objects in this study to investigate the effects of different softening method, slice thickness and drying methods on the quality of Notopterygii Rhizoma et Radix slices, and the experimental data were analyzed by homogeneous distance evaluation method. The results showed that different softening, cutting and drying processes could affect the content of five components in Notopterygii Rhizoma et Radix incisum. The best processing technology of Notopterygii Rhizoma et Radix slices was as follows: non-medicinal parts were removed; mildewed and rot as well as moth-eaten parts were removed; washed by the flowing drinking water; stacked in the drug pool; moistening method was used for softening, where 1/8 volume of water was sprayed for every 1 kg of herbs every 2 h; upper part of herbs covered with clean and moist cotton, and cut into thick slices (2-4 mm) after 12 h moistening until appropriate softness, then received blast drying for 4 h at 50 ℃, and turned over for 2 times during the drying. The process is practical and provides the experimental basis for the standardization of the processing of Notopterygii Rhizoma et Radix, with great significance to improve the quality of Notopterygii Rhizoma et Radix slices. Copyright© by the Chinese Pharmaceutical Association.

  13. Slice image pretreatment for cone-beam computed tomography based on adaptive filter

    International Nuclear Information System (INIS)

    Huang Kuidong; Zhang Dinghua; Jin Yanfang

    2009-01-01

    According to the noise properties and the serial slice image characteristics in Cone-Beam Computed Tomography (CBCT) system, a slice image pretreatment for CBCT based on adaptive filter was proposed. The judging criterion for the noise is established firstly. All pixels are classified into two classes: adaptive center weighted modified trimmed mean (ACWMTM) filter is used for the pixels corrupted by Gauss noise and adaptive median (AM) filter is used for the pixels corrupted by impulse noise. In ACWMTM filtering algorithm, the estimated Gauss noise standard deviation in the current slice image with offset window is replaced by the estimated standard deviation in the adjacent slice image to the current with the corresponding window, so the filtering accuracy of the serial images is improved. The pretreatment experiment on CBCT slice images of wax model of hollow turbine blade shows that the method makes a good performance both on eliminating noises and on protecting details. (authors)

  14. Drying characteristics of pumpkin ( Cucurbita moschata) slices in convective and freeze dryer

    Science.gov (United States)

    Caliskan, Gulsah; Dirim, Safiye Nur

    2017-06-01

    This study was intended to determine the drying and rehydration kinetics of convective and freeze dried pumpkin slices (0.5 × 3.5 × 0.5 cm). A pilot scale tray drier (at 80 ± 2 °C inlet temperature, 1 m s-1 air velocity) and freeze drier (13.33 kPa absolute pressure, condenser temperature of -48 ± 2 °C) were used for the drying experiments. Drying curves were fitted to six well-known thin layer drying models. Nonlinear regression analysis was used to evaluate the parameters of the selected models by using statistical software SPSS 16.0 (SPSS Inc., USA). For the convective and freeze drying processes of pumpkin slices, the highest R2 values, and the lowest RMSE as well as χ2 values were obtained from Page model. The effective moisture diffusivity (Deff) of the convective and freeze dried pumpkin slices were obtained from the Fick's diffusion model, and they were found to be 2.233 × 10-7 and 3.040 × 10-9 m2s-1, respectively. Specific moisture extraction rate, moisture extraction rate, and specific energy consumption values were almost twice in freeze drying process. Depending on the results, moisture contents and water activity values of pumpkin slices were in acceptable limits for safe storage of products. The rehydration behaviour of [at 18 ± 2 and 100 ± 2 °C for 1:25, 1:50, 1:75, 1:100, and 1:125 solid:liquid ratios (w:w)] dried pumpkin slices was determined by Peleg's model with the highest R2. The highest total soluble solid loss of pumpkin slices was observed for the rehydration experiment which performed at 1:25 solid: liquid ratio (w:w). Rehydration ratio of freeze dried slices was found 2-3 times higher than convective dried slices.

  15. MK-801, but not drugs acting at strychnine-insensitive glycine receptors, attenuate methamphetamine nigrostriatal toxicity.

    Science.gov (United States)

    Layer, R T; Bland, L R; Skolnick, P

    1993-10-15

    Repeated administration of methamphetamine (METH) results in damage to nigrostriatal dopaminergic neurons. Both competitive N-methyl-D-aspartate (NMDA) receptor antagonists and use-dependent cation channel blockers attenuate METH-induced damage. The objectives of the present study were to examine whether comparable reductions in METH-induced damage could be obtained by compounds acting at strychnine-insensitive glycine receptors on the NMDA receptor complex. Four injections of METH (5 mg/kg i.p.) resulted in a approximately 70.9% depletion of striatal dopamine (DA) and approximately 62.7% depletion of dihydroxyphenylacetic acid (DOPAC) content, respectively. A significant protection against METH-induced DA and DOPAC depletion was afforded by the use-dependent channel blocker, MK-801. The competitive glycine antagonist 7-chlorokynurenic acid (7-Cl-KA), the low efficacy glycine partial agonist (+)-3-amino-1-hydroxy-2-pyrrolidone ((+)-HA-966), and the high efficacy partial glycine agonist 1-aminocyclopropane-carboxylic acid (ACPC) were ineffective against METH-induced toxicity despite their abilities to attenuate glutamate-induced neurotoxicity under both in vivo and in vitro conditions. These results indicate that glycinergic ligands do not possess the same broad neuroprotective spectrum as other classes of NMDA antagonists.

  16. A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

    Science.gov (United States)

    Mitra, Jhimli; Srikantha, Abhilash; Sidibé, Désiré; Martí, Robert; Oliver, Arnau; Lladó, Xavier; Ghose, Soumya; Vilanova, Joan C.; Comet, Josep; Meriaudeau, Fabrice

    2012-02-01

    This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to perform an analysis based on shape and information theory to reach close enough to the actual MR slice as validated by experts. The Bhattacharyya distance is used to find point correspondences between shape-context representations of the prostate contours. Thereafter, Chi-square distance is used to find out those MR slices where the prostates closely match with that of the TRUS slice. Normalized Mutual Information (NMI) values of the TRUS slice with each of the axial MR slices are computed after rigid alignment and consecutively a strategic elimination based on a set of rules between the Chi-square distances and the NMI leads to the required MR slice. We validated our method for TRUS axial slices of 15 patients, of which 11 results matched at least one experts validation and the remaining 4 are at most one slice away from the expert validations.

  17. A comparative risk assessment for Listeria monocytogenes in prepackaged versus retail-sliced deli meat.

    Science.gov (United States)

    Endrikat, Sarah; Gallagher, Daniel; Pouillot, Régis; Hicks Quesenberry, Heather; Labarre, David; Schroeder, Carl M; Kause, Janell

    2010-04-01

    Deli meat was ranked as the highest-risk ready-to-eat food vehicle of Listeria monocytogenes within the 2003 U.S. Food and Drug Administration and U.S. Department of Agriculture, Food Safety and Inspection Service risk assessment. The comparative risk of L. monocytogenes in retail-sliced versus prepackaged deli meats was evaluated with a modified version of this model. Other research has found that retail-sliced deli meats have both higher prevalence and levels of L. monocytogenes than have product sliced and packaged at the manufacturer level. The updated risk assessment model considered slicing location as well as the use of growth inhibitors. The per annum comparative risk ratio for the number of deaths from retail-sliced versus prepackaged deli meats was found to be 4.89, and the per-serving comparative risk ratio was 4.27. There was a significant interaction between the use of growth inhibitors and slicing location. Almost 70% of the estimated deaths occurred from retail-sliced product that did not possess a growth inhibitor. A sensitivity analysis, assessing the effect of the model's consumer storage time and shelf life assumptions, found that even if retail-sliced deli meats were stored for a quarter of the time prepackaged deli meats were stored, retail-sliced product is 1.7 times more likely to result in death from listeriosis. Sensitivity analysis also showed that the shelf life assumption had little effect on the comparative risk ratio.

  18. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  19. Dosimetric variation due to CT inter-slice spacing in four-dimensional carbon beam lung therapy

    International Nuclear Information System (INIS)

    Kumagai, Motoki; Mori, Shinichiro; Kandatsu, Susumu; Baba, Masayuki; Sharp, Gregory C; Asakura, Hiroshi; Endo, Masahiro

    2009-01-01

    When CT data with thick slice thickness are used in treatment planning, geometrical uncertainty may induce dosimetric errors. We evaluated carbon ion dose variations due to different CT slice thicknesses using a four-dimensional (4D) carbon ion beam dose calculation, and compared results between ungated and gated respiratory strategies. Seven lung patients were scanned in 4D mode with a 0.5 mm slice thickness using a 256-multi-slice CT scanner. CT images were averaged with various numbers of images to simulate reconstructed images with various slice thicknesses (0.5-5.0 mm). Two scenarios were studied (respiratory-ungated and -gated strategies). Range compensators were designed for each of the CT volumes with coarse inter-slice spacing to cover the internal target volume (ITV), as defined from 4DCT. Carbon ion dose distribution was computed for each resulting ITV on the 0.5 mm slice 4DCT data. The accumulated dose distribution was then calculated using deformable registration for 4D dose assessment. The magnitude of over- and under-dosage was found to be larger with the use of range compensators designed with a coarser inter-slice spacing than those obtained with a 0.5 mm slice thickness. Although no under-dosage was observed within the clinical target volume (CTV) region, D95 remained at over 97% of the prescribed dose for the ungated strategy and 95% for the gated strategy for all slice thicknesses. An inter-slice spacing of less than 3 mm may be able to minimize dose variation between the ungated and gated strategies. Although volumes with increased inter-slice spacing may reduce geometrical accuracy at a certain respiratory phase, this does not significantly affect delivery of the accumulated dose to the target during the treatment course.

  20. Brain slice on a chip: opportunities and challenges of applying microfluidic technology to intact tissues.

    Science.gov (United States)

    Huang, Yu; Williams, Justin C; Johnson, Stephen M

    2012-06-21

    Isolated brain tissue, especially brain slices, are valuable experimental tools for studying neuronal function at the network, cellular, synaptic, and single channel levels. Neuroscientists have refined the methods for preserving brain slice viability and function and converged on principles that strongly resemble the approach taken by engineers in developing microfluidic devices. With respect to brain slices, microfluidic technology may 1) overcome the traditional limitations of conventional interface and submerged slice chambers and improve oxygen/nutrient penetration into slices, 2) provide better spatiotemporal control over solution flow/drug delivery to specific slice regions, and 3) permit successful integration with modern optical and electrophysiological techniques. In this review, we highlight the unique advantages of microfluidic devices for in vitro brain slice research, describe recent advances in the integration of microfluidic devices with optical and electrophysiological instrumentation, and discuss clinical applications of microfluidic technology as applied to brain slices and other non-neuronal tissues. We hope that this review will serve as an interdisciplinary guide for both neuroscientists studying brain tissue in vitro and engineers as they further develop microfluidic chamber technology for neuroscience research.

  1. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  2. Extension of shelf-life of Chickoo slices using hurdle technology

    International Nuclear Information System (INIS)

    Shirodkar, S.; Behere, A.G.; Padwal-Desai, S.R.; Lele, S.S.; Pai, J.S.

    2001-01-01

    An attempt has been made to evolve a protocol to prepare shelf-stable high moisture chickoo slices using Hurdle Technology. The process is based on a slight reduction of water activity (0.98?0.94) by osmosis with a 70 deg Brix sucrose syrup, lowering of pH (5.75 to 4.46) by addition of citric acid, addition of KMS and then subjecting the resulting slices to different doses of gamma radiation ranging from 0.25-1 kGy. Radiation processed chickoo slices remained acceptable for 8 weeks at sub-room temperature (10 ± 2 degC) and for 3 weeks at ambient temperature (28 ± 2 degC) when evaluated by a taste-test panel. (author)

  3. Thin-Slice Perception Develops Slowly

    Science.gov (United States)

    Balas, Benjamin; Kanwisher, Nancy; Saxe, Rebecca

    2012-01-01

    Body language and facial gesture provide sufficient visual information to support high-level social inferences from "thin slices" of behavior. Given short movies of nonverbal behavior, adults make reliable judgments in a large number of tasks. Here we find that the high precision of adults' nonverbal social perception depends on the slow…

  4. A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    Science.gov (United States)

    Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin

    2018-07-01

    Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. A rapid and simple method for cryopreservation of human liver slices

    NARCIS (Netherlands)

    de Kanter, R; Olinga, Peter; Hof, I.H; de Jager, M.H; Verwillegen, W.A; Slooff, M.JH; Meijer, D.K F; Groothuis, Geny; Koster, H

    1. Precision-cut liver slices represent a suitable and convenient in vitro preparation for studying metabolism and toxicity mechanisms of drugs and toxic chemicals. Particularly in the case of human liver slices, cryopreservation would enable more efficient utilization of this scarce and irregularly

  6. Precision-cut kidney slices (PCKS to study development of renal fibrosis and efficacy of drug targeting ex vivo

    Directory of Open Access Journals (Sweden)

    Fariba Poosti

    2015-10-01

    Full Text Available Renal fibrosis is a serious clinical problem resulting in the greatest need for renal replacement therapy. No adequate preventive or curative therapy is available that could be clinically used to target renal fibrosis specifically. The search for new efficacious treatment strategies is therefore warranted. Although in vitro models using homogeneous cell populations have contributed to the understanding of the pathogenetic mechanisms involved in renal fibrosis, these models poorly mimic the complex in vivo milieu. Therefore, we here evaluated a precision-cut kidney slice (PCKS model as a new, multicellular ex vivo model to study the development of fibrosis and its prevention using anti-fibrotic compounds. Precision-cut slices (200-300 μm thickness were prepared from healthy C57BL/6 mouse kidneys using a Krumdieck tissue slicer. To induce changes mimicking the fibrotic process, slices were incubated with TGFβ1 (5 ng/ml for 48 h in the presence or absence of the anti-fibrotic cytokine IFNγ (1 µg/ml or an IFNγ conjugate targeted to PDGFRβ (PPB-PEG-IFNγ. Following culture, tissue viability (ATP-content and expression of α-SMA, fibronectin, collagen I and collagen III were determined using real-time PCR and immunohistochemistry. Slices remained viable up to 72 h of incubation, and no significant effects of TGFβ1 and IFNγ on viability were observed. TGFβ1 markedly increased α-SMA, fibronectin and collagen I mRNA and protein expression levels. IFNγ and PPB-PEG-IFNγ significantly reduced TGFβ1-induced fibronectin, collagen I and collagen III mRNA expression, which was confirmed by immunohistochemistry. The PKCS model is a novel tool to test the pathophysiology of fibrosis and to screen the efficacy of anti-fibrotic drugs ex vivo in a multicellular and pro-fibrotic milieu. A major advantage of the slice model is that it can be used not only for animal but also for (fibrotic human kidney tissue.

  7. Adaptive SLICE method: an enhanced method to determine nonlinear dynamic respiratory system mechanics

    International Nuclear Information System (INIS)

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    The objective of this paper is to introduce and evaluate the adaptive SLICE method (ASM) for continuous determination of intratidal nonlinear dynamic compliance and resistance. The tidal volume is subdivided into a series of volume intervals called slices. For each slice, one compliance and one resistance are calculated by applying a least-squares-fit method. The volume window (width) covered by each slice is determined based on the confidence interval of the parameter estimation. The method was compared to the original SLICE method and evaluated using simulation and animal data. The ASM was also challenged with separate analysis of dynamic compliance during inspiration. If the signal-to-noise ratio (SNR) in the respiratory data decreased from +∞ to 10 dB, the relative errors of compliance increased from 0.1% to 22% for the ASM and from 0.2% to 227% for the SLICE method. Fewer differences were found in resistance. When the SNR was larger than 40 dB, the ASM delivered over 40 parameter estimates (42.2 ± 1.3). When analyzing the compliance during inspiration separately, the estimates calculated with the ASM were more stable. The adaptive determination of slice bounds results in consistent and reliable parameter values. Online analysis of nonlinear respiratory mechanics will profit from such an adaptive selection of interval size. (paper)

  8. Peripheral Inflammation Increases the Damage in Animal Models of Nigrostriatal Dopaminergic Neurodegeneration: Possible Implication in Parkinson's Disease Incidence

    Directory of Open Access Journals (Sweden)

    A. Machado

    2011-01-01

    Full Text Available Inflammatory processes described in Parkinson’s disease (PD and its animal models appear to be important in the progression of the pathogenesis, or even a triggering factor. Here we review that peripheral inflammation enhances the degeneration of the nigrostriatal dopaminergic system induced by different insults; different peripheral inflammations have been used, such as IL-1β and the ulcerative colitis model, as well as insults to the dopaminergic system such as 6-hydroxydopamine or lipopolysaccharide. In all cases, an increased loss of dopaminergic neurons was described; inflammation in the substantia nigra increased, displaying a great activation of microglia along with an increase in the production of cytokines such as IL-1β and TNF-α. Increased permeability or disruption of the BBB, with overexpression of the ICAM-1 adhesion molecule and infiltration of circulating monocytes into the substantia nigra, is also involved, since the depletion of circulating monocytes prevents the effects of peripheral inflammation. Data are reviewed in relation to epidemiological studies of PD.

  9. Target recognition of ladar range images using slice image: comparison of four improved algorithms

    Science.gov (United States)

    Xia, Wenze; Han, Shaokun; Cao, Jingya; Wang, Liang; Zhai, Yu; Cheng, Yang

    2017-07-01

    Compared with traditional 3-D shape data, ladar range images possess properties of strong noise, shape degeneracy, and sparsity, which make feature extraction and representation difficult. The slice image is an effective feature descriptor to resolve this problem. We propose four improved algorithms on target recognition of ladar range images using slice image. In order to improve resolution invariance of the slice image, mean value detection instead of maximum value detection is applied in these four improved algorithms. In order to improve rotation invariance of the slice image, three new improved feature descriptors-which are feature slice image, slice-Zernike moments, and slice-Fourier moments-are applied to the last three improved algorithms, respectively. Backpropagation neural networks are used as feature classifiers in the last two improved algorithms. The performance of these four improved recognition systems is analyzed comprehensively in the aspects of the three invariances, recognition rate, and execution time. The final experiment results show that the improvements for these four algorithms reach the desired effect, the three invariances of feature descriptors are not directly related to the final recognition performance of recognition systems, and these four improved recognition systems have different performances under different conditions.

  10. Color changes and acrylamide formation in fried potato slices

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Moyano, Pedro; Kaack, Karl

    2005-01-01

    The objective of this work was to study the kinetics of browning during deep-fat frying of blanched and unblanched potato chips by using the dynamic method and to find a relationship between browning development and acrylamide formation. Prior to frying, potato slices were blanched in hot water...... at 85degreesC for 3.5 min. Unblanched slices were used as the control. Control and blanched potato slices (Panda variety, diameter: 37 mm, width: 2.2 mm) were fried at 120, 150 and 180degreesC until reaching moisture contents of similar to1.8% (total basis) and their acrylamide content and final color...... were measured. Color changes were recorded at different sampling times during frying at the three mentioned temperatures using the chromatic redness parameter a(*). Experimental data of surface temperature, moisture content and color change in potato chips during frying were fit to empirical...

  11. Thin slices and Sherlock Holmes

    African Journals Online (AJOL)

    based on very little information, and often in a matter of seconds. This is partly based on very narrow slices of our experience, and involves pattern recognition, as well as the memory banks of our senses. It is also partly a heuristic process whereby one rapidly discards ideas or notions, or promotes other hypotheses, as one.

  12. Long-term, repeated dose in vitro neurotoxicity of the glutamate receptor antagonist L-AP3, demonstrated in rat hippocampal slice cultures by using continuous propidium iodide incubation

    DEFF Research Database (Denmark)

    Kristensen, Bjarne W; Blaabjerg, Morten; Noraberg, Jens

    2007-01-01

    ), which is known to be toxic in vivo after subchronic, but not acute, administration. Degenerative effects were monitored by measuring the cellular uptake of propidium iodide (PI; continuously present in the medium) and lactate dehydrogenase (LDH) leakage, and by using a panel of histological stains....... Hippocampal slices, derived from 2-3 day old rats and grown for 3 weeks, were subsequently exposed for the next 3 weeks to 0, 10 or 100microM L-AP3, with PI (2microM) in the culture medium. Exposure to 100microM L-AP3 induced severe toxicity after 4-6 days, shown by massive PI uptake, LDH leakage, changes...... in MAP2 and GFAP immunostaining, and in Nissl and Timm staining. In contrast, 10microM L-AP3 did not induce detectable neuronal degeneration. Treatment with the NMDA receptor antagonist, MK-801, or the AMPA/KA receptor antagonist NBQX, together with 100microM L-AP3, reduced neurodegeneration down...

  13. Time efficient whole-brain coverage with MR Fingerprinting using slice-interleaved echo-planar-imaging.

    Science.gov (United States)

    Rieger, Benedikt; Akçakaya, Mehmet; Pariente, José C; Llufriu, Sara; Martinez-Heras, Eloy; Weingärtner, Sebastian; Schad, Lothar R

    2018-04-27

    Magnetic resonance fingerprinting (MRF) is a promising method for fast simultaneous quantification of multiple tissue parameters. The objective of this study is to improve the coverage of MRF based on echo-planar imaging (MRF-EPI) by using a slice-interleaved acquisition scheme. For this, the MRF-EPI is modified to acquire several slices in a randomized interleaved manner, increasing the effective repetition time of the spoiled gradient echo readout acquisition in each slice. Per-slice matching of the signal-trace to a precomputed dictionary allows the generation of T 1 and T 2 * maps with integrated B 1 + correction. Subsequent compensation for the coil sensitivity profile and normalization to the cerebrospinal fluid additionally allows for quantitative proton density (PD) mapping. Numerical simulations are performed to optimize the number of interleaved slices. Quantification accuracy is validated in phantom scans and feasibility is demonstrated in-vivo. Numerical simulations suggest the acquisition of four slices as a trade-off between quantification precision and scan-time. Phantom results indicate good agreement with reference measurements (Difference T 1 : -2.4 ± 1.1%, T 2 *: -0.5 ± 2.5%, PD: -0.5 ± 7.2%). In-vivo whole-brain coverage of T 1 , T 2 * and PD with 32 slices was acquired within 3:36 minutes, resulting in parameter maps of high visual quality and comparable performance with single-slice MRF-EPI at 4-fold scan-time reduction.

  14. Electrophysiological and pharmacological evidence for the existence of distinct subpopulations of nigrostriatal dopaminergic neuron in the rat.

    Science.gov (United States)

    Shepard, P D; German, D C

    1988-11-01

    The electrophysiological and pharmacological properties of dopaminergic neurons were systematically examined throughout the anterior-posterior extent of the substantia nigra zona compacta in the rat. Cells were characterized in terms of their (1) firing pattern, (2) firing rate, (3) antidromic response properties, and (4) inhibition in firing rate following dopaminergic agonist administration. These properties were then related to the cell's position within one of four anterior-posterior segments of the nucleus. There were three types of neuronal discharge pattern encountered; irregular, burst and regular. Cells which exhibited different firing patterns exhibited different firing rates and anatomical locations within the substantia nigra zona compacta. All neurons were antidromically activated from the striatum, however, the burst- and regular-firing cells exhibited significantly faster estimated conduction velocities than irregular-firing cells. The irregular-firing cells were most sensitive to dopaminergic autoreceptor agonists whereas the burst-firing cells were most sensitive to an indirect-acting dopaminergic agonist. These experiments provide both electrophysiological and pharmacological evidence to indicate that nigrostriatal dopaminergic neurons are composed of distinct subpopulations which are characterized by their firing pattern.

  15. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  16. Development of an electrically operated cassava slicing machine

    Directory of Open Access Journals (Sweden)

    I. S. Aji

    2013-08-01

    Full Text Available Labor input in manual cassava chips processing is very high and product quality is low. This paper presents the design and construction of an electrically operated cassava slicing machine that requires only one person to operate. Efficiency, portability, ease of operation, corrosion prevention of slicing component of the machine, force required to slice a cassava tuber, capacity of 10 kg/min and uniformity in the size of the cassava chips were considered in the design and fabrication of the machine. The performance of the machine was evaluated with cassava of average length and diameter of 253 mm and 60 mm respectively at an average speed of 154 rpm. The machine produced 5.3 kg of chips of 10 mm length and 60 mm diameter in 1 minute. The efficiency of the machine was 95.6% with respect to the quantity of the input cassava. The chips were found to be well chipped to the designed thickness, shape and of generally similar size. Galvanized steel sheets were used in the cutting section to avoid corrosion of components. The machine is portable and easy to operate which can be adopted for cassava processing in a medium size industry.

  17. Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A.; Rousseau, Francois; Glenn, Orit A.; Barkovich, Anthony J.; Studholme, Colin

    2012-01-01

    In recent years post-processing of fast multi-slice MR imaging to correct fetal motion has provided the first true 3D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two step iterative process, where slices from the acquired data are re-aligned to an approximate 3D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3D reconstruction, and is limited in its ability to recover sub-voxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3D reconstructions containing clinically useful additional information not visible in the original 2D slices. PMID:19744911

  18. A fourth gradient to overcome slice dependent phase effects of voxel-sized coils in planar arrays.

    Science.gov (United States)

    Bosshard, John C; Eigenbrodt, Edwin P; McDougall, Mary P; Wright, Steven M

    2010-01-01

    The signals from an array of densely spaced long and narrow receive coils for MRI are complicated when the voxel size is of comparable dimension to the coil size. The RF coil causes a phase gradient across each voxel, which is dependent on the distance from the coil, resulting in a slice dependent shift of k-space. A fourth gradient coil has been implemented and used with the system's gradient set to create a gradient field which varies with slice. The gradients are pulsed together to impart a slice dependent phase gradient to compensate for the slice dependent phase due to the RF coils. However the non-linearity in the fourth gradient which creates the desired slice dependency also results in a through-slice phase ramp, which disturbs normal slice refocusing and leads to additional signal cancelation and reduced field of view. This paper discusses the benefits and limitations of using a fourth gradient coil to compensate for the phase due to RF coils.

  19. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  20. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  1. Fan beam image reconstruction with generalized Fourier slice theorem.

    Science.gov (United States)

    Zhao, Shuangren; Yang, Kang; Yang, Kevin

    2014-01-01

    For parallel beam geometry the Fourier reconstruction works via the Fourier slice theorem (or central slice theorem, projection slice theorem). For fan beam situation, Fourier slice can be extended to a generalized Fourier slice theorem (GFST) for fan-beam image reconstruction. We have briefly introduced this method in a conference. This paper reintroduces the GFST method for fan beam geometry in details. The GFST method can be described as following: the Fourier plane is filled by adding up the contributions from all fanbeam projections individually; thereby the values in the Fourier plane are directly calculated for Cartesian coordinates such avoiding the interpolation from polar to Cartesian coordinates in the Fourier domain; inverse fast Fourier transform is applied to the image in Fourier plane and leads to a reconstructed image in spacial domain. The reconstructed image is compared between the result of the GFST method and the result from the filtered backprojection (FBP) method. The major differences of the GFST and the FBP methods are: (1) The interpolation process are at different data sets. The interpolation of the GFST method is at projection data. The interpolation of the FBP method is at filtered projection data. (2) The filtering process are done in different places. The filtering process of the GFST is at Fourier domain. The filtering process of the FBP method is the ramp filter which is done at projections. The resolution of ramp filter is variable with different location but the filter in the Fourier domain lead to resolution invariable with location. One advantage of the GFST method over the FBP method is in short scan situation, an exact solution can be obtained with the GFST method, but it can not be obtained with the FBP method. The calculation of both the GFST and the FBP methods are at O(N^3), where N is the number of pixel in one dimension.

  2. Relationship between moisture content and electrical impedance of carrot slices during drying

    Science.gov (United States)

    Kertész, Ákos; Hlaváčová, Zuzana; Vozáry, Eszter; Staroňová, Lenka

    2015-01-01

    Electrical properties of food materials can give information about the inner structure and physiological state of biological tissues. Generally, the process of drying of fruits and vegetables is followed by weight loss. The aim of this study was to measure the impedance spectra of carrot slices during drying and to correlate impedance parameters to moisture content in different drying periods. Cylindrical slices were cut out from the carrot root along the axis. The slices were dried in a Venticell 111 air oven at 50°C. The weight of the slices was measured with a Denver SI-603 electronic analytical and precision balance. The weighing of the samples was performed every 30 min at the beginning of drying and every 60 min after the process. The moisture content of the samples was calculated on wet basis. The magnitude and phase angle of electrical impedance of the slices were measured with HP 4284A and 4285A precision LCR meters in the frequency range from 30 Hz to 1 MHz and from 75 kHz to 30 MHz, respectively, at voltage 1 V. The impedance measurement was performed after weighting. The change in the magnitude of impedance during drying showed a good correlation with the change in the moisture content.

  3. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Real-time slicing algorithm for Stereolithography (STL) CAD model applied in additive manufacturing industry

    Science.gov (United States)

    Adnan, F. A.; Romlay, F. R. M.; Shafiq, M.

    2018-04-01

    Owing to the advent of the industrial revolution 4.0, the need for further evaluating processes applied in the additive manufacturing application particularly the computational process for slicing is non-trivial. This paper evaluates a real-time slicing algorithm for slicing an STL formatted computer-aided design (CAD). A line-plane intersection equation was applied to perform the slicing procedure at any given height. The application of this algorithm has found to provide a better computational time regardless the number of facet in the STL model. The performance of this algorithm is evaluated by comparing the results of the computational time for different geometry.

  5. Antibrowning and antimicrobial properties of sodium acid sulfate in apple slices.

    Science.gov (United States)

    Fan, Xuetong; Sokorai, Kimberly J B; Liao, Ching-Hsing; Cooke, Peter; Zhang, Howard Q

    2009-01-01

    There are few available compounds that can both control browning and enhance microbial safety of fresh-cut fruits. In the present study, the antibrowning ability of sodium acid sulfate (SAS) on "Granny Smith" apple slices was first investigated in terms of optimum concentration and treatment time. In a separate experiment, the apple slices were treated with water or 3% of SAS, calcium ascorbate, citric acid, or acidified calcium sulfate for 5 min. Total plate count, color, firmness, and tissue damage were assessed during a 21-d storage at 4 degrees C. Results showed that the efficacy of SAS in inhibiting browning of apple slices increased with increasing concentration. A minimum 3% of SAS was needed to achieve 14 d of shelf life. Firmness was not significantly affected by SAS at 3% or lower concentrations. Antibrowning potential of SAS was similar for all treatment times ranging from 2 to 10 min. However, SAS caused some skin discoloration of apple slices. When cut surface of apple slices were stained with a fluorescein diacetate solution, tissue damage could be observed under a microscope even though visual damage was not evident. Among the antibrowning agents tested, SAS was the most effective in inhibiting browning and microbial growth for the first 14 d. Total plate count of samples treated with 3% SAS was significantly lower than those treated with calcium ascorbate, a commonly used antibrowning agent. Our results suggested that it is possible to use SAS to control browning while inhibiting the growth of microorganisms on the apple slices if the skin damage can be minimized. Practical Application: Fresh-cut apples have emerged as one of the popular products in restaurants, schools, and food service establishments as more consumers demand fresh, convenient, and nutritious foods. Processing of fresh-cut apples induces mechanical damage to the fruit and exposes apple tissue to air, resulting in the development of undesirable tissue browning. The fresh

  6. Concept and development of measurement method of time sensitivity profile (TSP) in X-ray CT. Comparison of non-helical, single-slice helical, and multi-slice helical scans

    International Nuclear Information System (INIS)

    Tsujioka, Katsumi; Ida, Yoshihiro; Ohtsubo, Hironori; Takahashi, Yasukata; Niwa, Masayoshi

    2000-01-01

    We focused on the time element contained in a single CT image, and devised the concept of a time-sensitivity profile (TSP) describing how the time element is translated into an image. We calculated the data collection time range when the helical pitch is changed in non helical scans, single slice helical scans, and multi slice helical scans. We then calculated the time sensitivity profile (TSP) from the weighting applied when the data collection time range is translated into an image. TSP was also measured for each scanning method using our self-made moving phantom. TSPs obtained from the calculation and the experiments were very close. TSP showed interesting characteristics with each scanning method, especially in the case of multi slice helical scanning, in which TSP became shorter as helical pitch increased. We referred to the TSP's FWHM as the effective scanning time. When we conducted multi slice helical scanning at helical pitch 3, the effective scanning time increased to about 24% longer than that of a non helical scan. When we conducted multi slice helical scanning at helical pitch 5 or 6, the effective scanning time was about half that of a non helical scan. The time sensitivity profile (TSP) is a totally new concept that we consider an important element in discussing the time resolution of a CT scanner. The results of this review will provide significant data in determining the scanning parameters when scanning a moving object. (author)

  7. Microbiological quality of sliced and block mozzarella cheese

    Directory of Open Access Journals (Sweden)

    Mariana Fontanetti Marinheiro

    2015-06-01

    Full Text Available The aim of this study was to verify the microbiological quality of mozzarella cheese sold in retail markets of Pelotas, Rio Grande do Sul, Brazil. Forty samples of mozzarella cheese were analyzed, comprising 20 samples of block cheese and 20 of sliced cheese. The cheese samples were analyzed for thermotolerant coliform counts and coagulase positive staphylococci counts, and presence of Salmonella spp and Listeria monocytogenes. The percentage of 12,5% and 5% of the sliced and block cheese samples analyzed, respectively, exceeded the microbiological standards accepted by Brazilian legislation. These results indicate the need for a better product monitoring and more concern with hygiene and sanitary practices during industrial process.

  8. Pre-sliced fruit in school cafeterias: children's selection and intake.

    Science.gov (United States)

    Wansink, Brian; Just, David R; Hanks, Andrew S; Smith, Laura E

    2013-05-01

    It is often assumed that children avoid fruit in school cafeterias because of higher relative prices and preferences for other foods. Interviews with children reveal that eating whole fresh fruit can be difficult for those with small mouths or braces. Older girls find whole fruits messy and unattractive to eat. To determine the effect of offering pre-sliced fruit in schools on selection and intake. Three of six schools were assigned randomly to serve apples in slices. Three control schools served apples whole. Selection, consumption, and waste of apples were measured prior to and during treatment. Cafeterias in six public middle schools in Wayne County NY in 2011. Participants included all students who purchased lunch on days when data were collected. Treatment schools were provided with a standard commercial fruit slicer, and cafeteria staff members were instructed to use it when students requested apples. Trained researchers recorded how much of each apple was consumed and how much was wasted in both control and treatment schools. Daily apple sales, percentage of an apple serving consumed per student, and percentage of an apple serving wasted per student. Data were analyzed in 2012. Schools that used fruit slicers to pre-slice fruit increased average daily apple sales by 71% compared to control schools (papples and ate more than half increased by 73% (p=0.02) at schools that served pre-sliced fruit, and the percentage that wasted half or more decreased by 48% (p=0.03). Sliced fruit is more appealing to children than whole fruit because it is easier and tidier to eat. This study applies the principle of convenience from behavioral economics and provides an example of a scalable, low-cost environmental change that promotes healthy eating and decreases waste. Copyright © 2013. Published by Elsevier Inc. on behalf of American Journal of Preventive Medicine.

  9. Influence of image slice thickness on rectal dose–response relationships following radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Olsson, C; Thor, M; Apte, A; Deasy, J O; Liu, M; Moissenko, V; Petersen, S E; Høyer, M

    2014-01-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose–response relationships. We investigated this for rectal bleeding using dose–volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman–Kutcher–Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose–response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice

  10. Dried fruit breadfruit slices by Refractive Window™ technique

    Directory of Open Access Journals (Sweden)

    Diego F. Tirado

    2016-01-01

    Full Text Available A large amount of products are dried due several reasons as preservation, weight reduction and improvement of stability. However, on the market are not offered low-cost and high quality products simultaneously. Although there are effective methods of dehydrating foods such as freeze drying, which preserves the flavor, color and vitamins, they are poor accessibility technologies. Therefore, alternative processes are required to be efficient and economical. The aim of this research was compare drying kinetics of sliced of breadfruit (Artocarpus communis using the technique of Refractive Window® (VR with the tray drying. To carry out this study, sliced of 1 and 2 mm thick were used. Refractive window drying was performed with the water bath temperature to 92 °C; and tray drying at 62 °C and an air velocity of 0.52 m/s. During the Refractive window drying technique, the moisture content reached the lower than tray drying levels. Similarly it happened with samples of 1 mm, which, having a smaller diameter reached lower moisture levels than samples 2 mm. The higher diffusivities were obtained during drying sliced VR 1 and 2 mm with coefficients of 6.13 and 3.90*10-9 m2/s respectively.

  11. Early increase and late decrease of purkinje cell dendritic spine density in prion-infected organotypic mouse cerebellar cultures.

    Science.gov (United States)

    Campeau, Jody L; Wu, Gengshu; Bell, John R; Rasmussen, Jay; Sim, Valerie L

    2013-01-01

    Prion diseases are infectious neurodegenerative diseases associated with the accumulation of protease-resistant prion protein, neuronal loss, spongiform change and astrogliosis. In the mouse model, the loss of dendritic spines is one of the earliest pathological changes observed in vivo, occurring 4-5 weeks after the first detection of protease-resistant prion protein in the brain. While there are cell culture models of prion infection, most do not recapitulate the neuropathology seen in vivo. Only the recently developed prion organotypic slice culture assay has been reported to undergo neuronal loss and the development of some aspects of prion pathology, namely small vacuolar degeneration and tubulovesicular bodies. Given the rapid replication of prions in this system, with protease-resistant prion protein detectable by 21 days, we investigated whether the dendritic spine loss and altered dendritic morphology seen in prion disease might also develop within the lifetime of this culture system. Indeed, six weeks after first detection of protease-resistant prion protein in tga20 mouse cerebellar slice cultures infected with RML prion strain, we found a statistically significant loss of Purkinje cell dendritic spines and altered dendritic morphology in infected cultures, analogous to that seen in vivo. In addition, we found a transient but statistically significant increase in Purkinje cell dendritic spine density during infection, at the time when protease-resistant prion protein was first detectable in culture. Our findings support the use of this slice culture system as one which recapitulates prion disease pathology and one which may facilitate study of the earliest stages of prion disease pathogenesis.

  12. Attenuation of 6-hydroxydopamine-induced dopaminergic nigrostriatal lesions in superoxide dismutase transgenic mice

    International Nuclear Information System (INIS)

    Cadet, J.L.; Hirata, H.; Asanuma, M.

    1998-01-01

    6-Hydroxydopamine is a neurotoxin that produces degeneration of the nigrostriatal dopaminergic pathway in rodents. Its toxicity is thought to involve the generation of superoxide anion secondary to its autoxidation. To examine the effects of the overexpression of Cu,Zn-superoxide dismutase activity on 6-hydroxydopamine-induced dopaminergic neuronal damage, we have measured the effects of 6-hydroxydopamine on striatal and nigral dopamine transporters and nigral tyrosine hydroxylase-immunoreactive neurons in Cu,Zn-superoxide dismutase transgenic mice. Intracerebroventricular injection of 6-hydroxydopamine (50 μg) in non-transgenic mice produced reductions in the size of striatal area and an enlargement of the cerebral ventricle on both sides of the brains of mice killed two weeks after the injection. In addition, 6-hydroxydopamine caused marked decreases in striatal and nigral [ 125 I]RTI-121-labelled dopamine transporters not only on the injected side but also on the non-injected side of non-transgenic mice; this was associated with decreased cell number and size of tyrosine hydroxylase-immunoreactive dopamine neurons in the substantia nigra pars compacta on both sides in these mice. In contrast, superoxide dismutase transgenic mice were protected against these neurotoxic effects of 6-hydroxydopamine, with the homozygous transgenic mice showing almost complete protection.These results provide further support for a role of superoxide anion in the toxic effects of 6-hydroxydopamine. They also provide further evidence that reactive oxygen species may be the main determining factors in the neurodegenerative effects of catecholamines. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  13. Study on tissue culture for Gelidium seedling

    Science.gov (United States)

    Pei, Lu-Qing; Luo, Qi-Jun; Fei, Zhi-Qing; Ma, Bin

    1996-06-01

    As seedling culture is a crucial factor for successful cultivation of Gelidium, the authors researched tissue culture technology for producing seedlings. The morphogeny and experimental ecology were observed and studied fully in 2 5 mm isolated tissue fragments. Regeneration, appearance of branching creepers and attaching structure and new erect seedlings production and development were studied. Fragments were sown on bamboo slice and vinylon rope. The seedlings were cultured 20 30 days indoor, then cultured in the sea, where the density of erect seedlings was 3 19 seedlings/cm2, growth rate was 3.84% day. The frond arising from seedlings directly was up to 10 cm per year. The ecological conditions for regenerated seedlings are similar to the natural ones. The regenerated seedlings are suitable for raft culture in various sea areas.

  14. Blanching, salting and sun drying of different pumpkin fruit slices.

    Science.gov (United States)

    Workneh, T S; Zinash, A; Woldetsadik, K

    2014-11-01

    The study was aimed at assessing the quality of pumpkin (Cucuribita Spp.) slices that were subjected to pre-drying treatments and drying using two drying methods (uncontrolled sun and oven) fruit accessions. Pre-drying had significant (P ≤ 0.05) effect on the quality of dried pumpkin slices. 10 % salt solution dipped pumpkin fruit slices had good chemical quality. The two-way interaction between drying methods and pre-drying treatments had significant (P ≤ 0.05) effect on chemical qualities. Pumpkin subjected to salt solution dipping treatment and oven dried had higher chemical concentrations. Among the pumpkin fruit accessions, pumpkin accession 8007 had the superior TSS, total sugar and sugar to acid ratio after drying. Among the three pre-drying treatment, salt solution dipping treatment had significant (P ≤ 0.05) effect and the most efficient pre-drying treatment to retain the quality of dried pumpkin fruits without significant chemical quality deterioration. Salt dipping treatment combined with low temperature (60 °C) oven air circulation drying is recommended to maintain quality of dried pumpkin slices. However, since direct sun drying needs extended drying time due to fluctuation in temperature, it is recommended to develop or select best successful solar dryer for use in combination with pre-drying salt dipping or blanching treatments.

  15. Automatic Solitary Lung Nodule Detection in Computed Tomography Images Slices

    Science.gov (United States)

    Sentana, I. W. B.; Jawas, N.; Asri, S. A.

    2018-01-01

    Lung nodule is an early indicator of some lung diseases, including lung cancer. In Computed Tomography (CT) based image, nodule is known as a shape that appears brighter than lung surrounding. This research aim to develop an application that automatically detect lung nodule in CT images. There are some steps in algorithm such as image acquisition and conversion, image binarization, lung segmentation, blob detection, and classification. Data acquisition is a step to taking image slice by slice from the original *.dicom format and then each image slices is converted into *.tif image format. Binarization that tailoring Otsu algorithm, than separated the background and foreground part of each image slices. After removing the background part, the next step is to segment part of the lung only so the nodule can localized easier. Once again Otsu algorithm is use to detect nodule blob in localized lung area. The final step is tailoring Support Vector Machine (SVM) to classify the nodule. The application has succeed detecting near round nodule with a certain threshold of size. Those detecting result shows drawback in part of thresholding size and shape of nodule that need to enhance in the next part of the research. The algorithm also cannot detect nodule that attached to wall and Lung Chanel, since it depend the searching only on colour differences.

  16. Adaptive slices for acquisition of anisotropic BRDF

    Czech Academy of Sciences Publication Activity Database

    Vávra, Radomír; Filip, Jiří

    (2018) ISSN 2096-0433 R&D Projects: GA ČR GA17-18407S Institutional support: RVO:67985556 Keywords : anisotropic BRDF * slice * sampling Subject RIV: BD - Theory of Information http://library.utia.cas.cz/separaty/2018/RO/vavra-0486116.pdf

  17. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    Energy Technology Data Exchange (ETDEWEB)

    Ng, H.P. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Foong, K.W.C. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Dept. of Preventive Dentistry, National Univ. of Singapore (Singapore); Ong, S.H. [Dept. of Electrical and Computer Engineering, National Univ. of Singapore (Singapore); Div. of Bioengineering, National Univ. of Singapore (Singapore); Liu, J.; Nowinski, W.L. [Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Goh, P.S. [Dept. of Diagnostic Radiology, National Univ. of Singapore (Singapore)

    2007-06-15

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices ({kappa}) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  18. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    International Nuclear Information System (INIS)

    Ng, H.P.; Foong, K.W.C.; Ong, S.H.; Liu, J.; Nowinski, W.L.; Goh, P.S.

    2007-01-01

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices (κ) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  19. Evaluation of registration strategies for multi-modality images of rat brain slices

    International Nuclear Information System (INIS)

    Palm, Christoph; Vieten, Andrea; Salber, Dagmar; Pietrzyk, Uwe

    2009-01-01

    In neuroscience, small-animal studies frequently involve dealing with series of images from multiple modalities such as histology and autoradiography. The consistent and bias-free restacking of multi-modality image series is obligatory as a starting point for subsequent non-rigid registration procedures and for quantitative comparisons with positron emission tomography (PET) and other in vivo data. Up to now, consistency between 2D slices without cross validation using an inherent 3D modality is frequently presumed to be close to the true morphology due to the smooth appearance of the contours of anatomical structures. However, in multi-modality stacks consistency is difficult to assess. In this work, consistency is defined in terms of smoothness of neighboring slices within a single modality and between different modalities. Registration bias denotes the distortion of the registered stack in comparison to the true 3D morphology and shape. Based on these metrics, different restacking strategies of multi-modality rat brain slices are experimentally evaluated. Experiments based on MRI-simulated and real dual-tracer autoradiograms reveal a clear bias of the restacked volume despite quantitatively high consistency and qualitatively smooth brain structures. However, different registration strategies yield different inter-consistency metrics. If no genuine 3D modality is available, the use of the so-called SOP (slice-order preferred) or MOSOP (modality-and-slice-order preferred) strategy is recommended.

  20. Imaging by the SSFSE single slice method at different viscosities of bile

    International Nuclear Information System (INIS)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi

    2001-01-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T 2 . However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T 2 value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T 2 value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T 1 - and T 2 -weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T 2 values of the bile samples showing relatively high signal intensities on the T 1 -weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T 1 -weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  1. Cryopreservation of Precision-cut Tissue Slices for Application in Drug Metabolism Research

    NARCIS (Netherlands)

    Graaf, Inge Anne Maria de

    2002-01-01

    The research described in this thesis had two important aims. The first was to determine whether tissue slices could be used as an in vitro tool to predict the in vivo metabolism of new drugs. The second aim was to find a manner to store tissue slices for longer time periods by cryopreservation.

  2. Velocity slice imaging for dissociative electron attachment

    Science.gov (United States)

    Nandi, Dhananjay; Prabhudesai, Vaibhav S.; Krishnakumar, E.; Chatterjee, A.

    2005-05-01

    A velocity slice imaging method is developed for measuring the angular distribution of fragment negative ions arising from dissociative electron attachment (DEA) to molecules. A low energy pulsed electron gun, a pulsed field ion extraction, and a two-dimensional position sensitive detector consisting of microchannel plates and a wedge-and-strip anode are used for this purpose. Detection and storage of each ion separately for its position and flight time allows analysis of the data offline for any given time slice, without resorting to pulsing the detector bias. The performance of the system is evaluated by measuring the angular distribution of O- from O2 and comparing it with existing data obtained using conventional technique. The capability of this technique in obtaining forward and backward angular distribution data is shown to have helped in resolving one of the existing problems in the electron scattering on O2.

  3. Demonstration of the pulmonary interlobar fissures on multiplanar reformatted images with 64-slices spiral CT

    International Nuclear Information System (INIS)

    Wang Yafei; Chen Yerong; Shan Xiuhong; Tang Zhiyang; Ni Enzhen; Huang Hao; Wu Shuchun

    2009-01-01

    Objective: To determine the optimal orientation and slice thickness of reformatted images to visualize the interlobar fissures on multiplanar reformation (MPR) images and to recommend MPR imaging protocal for visualizing interlobar fissures in clinical practise. Methods: 64-slices CT scans of chest were obtained in 300 patients without pulmonary diseases. Axial, sagittal and coronal images were reformatted at 1, 2, 3, 7 mm slice thickness respectively from the raw volume data. Three experienced radiologists evaluated all of the MPR images in the lung window and compared the differences in visualization of the interlohar fissures among the three reformatted orientations and at the different slice thicknesses with Fisher test and Friedman test. Results: Fissures on sagittal MPR images using 1, 2, 3, and 7 mm reformatted slice thickness appeared as a fine line and the preference value analysis showed the MPR images with a 3 mm reformatted slice thickness is the best for visualizing the interlobar fissure. Compared to the sagittal orientation, the coronal was not as good and the axial was the worst among the three orientations. The coronal images with a 3 mm reformatted slice thickness were slightly inferior to sagittal images. The right horizontal fissures were observed as a fine line in all coronal image in 94.0% (282)of cases and in some of the images in 6.0% (18) of cases, the right oblique fissures were displayed as a fine line in coronal images in 2.3% (7) of cases and in some images in 85.0% (255) of cases, the left oblique fissures were displayed as a fine line in some coronal images in 35.7% (107) of cases and displayed as a coarse line in 64.3% (193) of cases. On axial MPR images using 3 mm reformation slice thickness, the right oblique fissures and the left oblique fissures were displayed as a fine line in some axial images in 79.3% (238) and 81.0% (243) of cases respectively, none of the images showed horizontal fissures as a fine line. There was

  4. Live cell imaging of cytosolic NADH/NAD+ ratio in hepatocytes and liver slices.

    Science.gov (United States)

    Masia, Ricard; McCarty, William J; Lahmann, Carolina; Luther, Jay; Chung, Raymond T; Yarmush, Martin L; Yellen, Gary

    2018-01-01

    Fatty liver disease (FLD), the most common chronic liver disease in the United States, may be caused by alcohol or the metabolic syndrome. Alcohol is oxidized in the cytosol of hepatocytes by alcohol dehydrogenase (ADH), which generates NADH and increases cytosolic NADH/NAD + ratio. The increased ratio may be important for development of FLD, but our ability to examine this question is hindered by methodological limitations. To address this, we used the genetically encoded fluorescent sensor Peredox to obtain dynamic, real-time measurements of cytosolic NADH/NAD + ratio in living hepatocytes. Peredox was expressed in dissociated rat hepatocytes and HepG2 cells by transfection, and in mouse liver slices by tail-vein injection of adeno-associated virus (AAV)-encoded sensor. Under control conditions, hepatocytes and liver slices exhibit a relatively low (oxidized) cytosolic NADH/NAD + ratio as reported by Peredox. The ratio responds rapidly and reversibly to substrates of lactate dehydrogenase (LDH) and sorbitol dehydrogenase (SDH). Ethanol causes a robust dose-dependent increase in cytosolic NADH/NAD + ratio, and this increase is mitigated by the presence of NAD + -generating substrates of LDH or SDH. In contrast to hepatocytes and slices, HepG2 cells exhibit a relatively high (reduced) ratio and show minimal responses to substrates of ADH and SDH. In slices, we show that comparable results are obtained with epifluorescence imaging and two-photon fluorescence lifetime imaging (2p-FLIM). Live cell imaging with Peredox is a promising new approach to investigate cytosolic NADH/NAD + ratio in hepatocytes. Imaging in liver slices is particularly attractive because it allows preservation of liver microanatomy and metabolic zonation of hepatocytes. NEW & NOTEWORTHY We describe and validate a new approach for measuring free cytosolic NADH/NAD + ratio in hepatocytes and liver slices: live cell imaging with the fluorescent biosensor Peredox. This approach yields dynamic, real

  5. Analysis of aliasing artifacts in 16-slice helical CT

    International Nuclear Information System (INIS)

    Chen Wei; Liu Jingkang; Ou Xiaoguang; Li Wenzheng; Liao Weihua; Yan Ang

    2006-01-01

    Objective: To recognize the features of aliasing artifacts on CT images, and to investigate the effects of imaging parameters on the magnitude of this artifacts. Methods: An adult dry skull was placed in a plastic water-filled container and scanned with a PHILIPS 16-slice helical CT. All the acquired transaxial images by using several different acquisition or reconstruction parameters were examined for comparative assessment of the aliasing artifacts. Results: The aliasing artifacts could be seen in most instances and characterized as the spokewise patterns emanating from the edges of high contrast structure as its radius varies sharply in the longitudinal direction. The images that scanned with pitch of 0.3, 0.6 and 0.9, respectively, showed aliasing artifacts, and its severities increased with pitches escalated (detector combination 16 x 1.5, reconstruction thickness 2 mm); There were more significant aliasing artifacts on the images reconstructed with 0.8 mm slice width compared with 1-mm slice width, and no aliasing artifacts were observed on the images reconstructed with 2-mm slice width (detector combination 16 x 0.75, pitch 0.6); No artifacts were perceived on the images scanned with detector combination 16 x 0.75, while presented evidently with the use of detector combination 16 x 1.5 (pitch 0.6, reconstruction thickness 2 mm); The degrees of aliasing artifacts were unaltered when reconstruction interval and tube current changed. Conclusions: Aliasing artifacts are caused by undersampling. When the operator choose the thinner sampling thickness, lower pitch and a much wider reconstruction thickness judiciously, aliasing artifacts could be effectively mitigated or suppressed. (authors)

  6. Influence of image slice thickness on rectal dose-response relationships following radiotherapy of prostate cancer

    Science.gov (United States)

    Olsson, C.; Thor, M.; Liu, M.; Moissenko, V.; Petersen, S. E.; Høyer, M.; Apte, A.; Deasy, J. O.

    2014-07-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose-response relationships. We investigated this for rectal bleeding using dose-volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman-Kutcher-Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose-response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice thickness

  7. Impact of whey protein coating incorporated with Bifidobacterium and Lactobacillus on sliced ham properties.

    Science.gov (United States)

    Odila Pereira, Joana; Soares, José; J P Monteiro, Maria; Gomes, Ana; Pintado, Manuela

    2018-05-01

    Edible coatings/films with functional ingredients may be a solution to consumers' demands for high-quality food products and an extended shelf-life. The aim of this work was to evaluate the antimicrobial efficiency of edible coatings incorporated with probiotics on sliced ham preservation. Coatings was developed based on whey protein isolates with incorporation of Bifidobacterium animalis Bb-12® or Lactobacillus casei-01. The physicochemical analyses showed that coating decreased water and weight loss on the ham. Furthermore, color analysis showed that coated sliced ham, exhibited no color change, comparatively to uncoated slices. The edible coatings incorporating the probiotic strains inhibited detectable growth of Staphylococcus spp., Pseudomonas spp., Enterobacteriaceae and yeasts/molds, at least, for 45days of storage at 4°C. The sensory evaluation demonstrated that there was a preference for the sliced coated ham. Probiotic bacteria viable cell numbers were maintained at ca. 10 8 CFU/g throughout storage time, enabling the slice of ham to act as a suitable carrier for the beneficial bacteria. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  9. Slicing Method for curved façade and window extraction from point clouds

    Science.gov (United States)

    Iman Zolanvari, S. M.; Laefer, Debra F.

    2016-09-01

    Laser scanning technology is a fast and reliable method to survey structures. However, the automatic conversion of such data into solid models for computation remains a major challenge, especially where non-rectilinear features are present. Since, openings and the overall dimensions of the buildings are the most critical elements in computational models for structural analysis, this article introduces the Slicing Method as a new, computationally-efficient method for extracting overall façade and window boundary points for reconstructing a façade into a geometry compatible for computational modelling. After finding a principal plane, the technique slices a façade into limited portions, with each slice representing a unique, imaginary section passing through a building. This is done along a façade's principal axes to segregate window and door openings from structural portions of the load-bearing masonry walls. The method detects each opening area's boundaries, as well as the overall boundary of the façade, in part, by using a one-dimensional projection to accelerate processing. Slices were optimised as 14.3 slices per vertical metre of building and 25 slices per horizontal metre of building, irrespective of building configuration or complexity. The proposed procedure was validated by its application to three highly decorative, historic brick buildings. Accuracy in excess of 93% was achieved with no manual intervention on highly complex buildings and nearly 100% on simple ones. Furthermore, computational times were less than 3 sec for data sets up to 2.6 million points, while similar existing approaches required more than 16 hr for such datasets.

  10. Reduction of acrylamide formation in potato slices during frying

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Kaack, K.; Granby, Kit

    2004-01-01

    and 40 min; 90degreesC for 2 and 9 min); (iii) immersed in citric acid solutions of different concentrations (10 and 20 g/l) for half an hour. Glucose and asparagine concentration was determined in potato slices before frying, whereas acrylamide content was determined in the resultant fried potato chips...... on average 76% and 68% of the glucose and asparagine content compared to the control. Potato slices blanched at 50degreesC for 70 min surprisingly had a very low acrylamide content (28 mum/kg) even when they were fried at 190degreesC. Potato immersion in citric acid solutions of 10 and 20 g/l reduced...

  11. HUMAN LIVER SLICES EXPRESS THE SAME LIDOCAINE BIOTRANSFORMATION RATE AS ISOLATED HUMAN HEPATOCYTES

    NARCIS (Netherlands)

    OLINGA, P; MEIJER, DKF; SLOOFF, MJH; GROOTHUIS, GMM; Merema, M.T.

    1993-01-01

    In order to investigate whether liver slices are a valuable tool for the assessment of drug metabolism in human liver, we compared the phase I metabolism of lidocaine in human liver slices and hepatocytes prepared from three human livers. Lidocaine is mainly metabolised to monoethylglycinexylidide

  12. Does slice thickness affect diagnostic performance of 64-slice CT coronary angiography in stable and unstable angina patients with a positive calcium score?

    Energy Technology Data Exchange (ETDEWEB)

    Meijs, Matthijs F.L.; Vos, Alexander M. de; Cramer, Maarten J.; Doevendans, Pieter A.; Vries, Jan J.J. de; Rutten, Annemarieke; Budde, Ricardo P.J.; Prokop, Mathias (Dept. of Radiology, Univ. Medical Center Utrecht, Utrecht (Netherlands)), e-mail: m.meijs@umcutrecht.nl; Meijboom, W. Bob; Feyter, Pim J. de (Dept. of Cardiology, Erasmus Medical Center, Rotterdam (Netherlands))

    2010-05-15

    Background: Coronary calcification can lead to over-estimation of the degree of coronary stenosis. Purpose: To evaluate whether thinner reconstruction thickness improves the diagnostic performance of 64-slice CT coronary angiography (CTCA) in angina patients with a positive calcium score. Material and Methods: We selected 20 scans from a clinical study comparing CTCA to conventional coronary angiography (CCA) in stable and unstable angina patients based on a low number of motion artifacts and a positive calcium score. All images were acquired at 64 x 0.625 mm and each CTCA scan was reconstructed at slice thickness/increment 0.67 mm/0.33 mm, 0.9 mm/0.45 mm, and 1.4 mm/0.7 mm. Two reviewers blinded for CCA results independently evaluated the scans for the presence of significant coronary artery disease (CAD) in three randomly composed series, with =2 weeks in between series. The diagnostic performance of CTCA was compared for the different slice thicknesses using a pooled analysis of both reviewers. Significant CAD was defined as >50% diameter narrowing on quantitative CCA. Image noise (standard deviation of CT numbers) was measured in all scans. Inter-observer variability was assessed with kappa. Results: Significant CAD was present in 8% of 304 available segments. Median total Agatston calcium score was 181.8 (interquartile range 34.9-815.6). Sensitivity at 0.67 mm, 0.9 mm, and 1.4 mm slice thickness was 70% (95% confidence interval 57-83%), 74% (62-86%), and 70% (57-83%), respectively. Specificity was 85% (82-88%), 84% (81-87%), and 84% (81-87%), respectively. The positive predictive value was 30 (21-38%), 29 (21-37%), and 28 (20-36%), respectively. The negative predictive value was 97% (95-98%), 97% (96-99%), and 97% (96-99%), respectively. Kappa for inter-observer agreement was 0.56, 0.58, and 0.59. Noise decreased from 32.9 HU at 0.67 mm, to 23.2 HU at 1.4 mm (P<0.001). Conclusion: Diagnostic performance of CTCA in angina patients with a positive calcium score

  13. In vitro imaging of coronary artery stents: Are there differences between 16- and 64-slice CT scanners?

    International Nuclear Information System (INIS)

    Wolf, Florian; Feuchtner, Gudrun M.; Homolka, Peter; Langenberger, Herbert; Stadler, Alfred; Bader, Till R.; Weber, Michael; Lammer, Johannes; Loewe, Christian

    2008-01-01

    Purpose: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. Methods and materials: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. Results: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p = 0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p = 0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p = 0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p = 0.866). Conclusion: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo

  14. Imaging by the SSFSE single slice method at different viscosities of bile

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi [Kawasaki Hospital, Kobe (Japan)

    2001-11-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T{sub 2}. However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T{sub 2} value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T{sub 2} value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T{sub 1}- and T{sub 2}-weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T{sub 2} values of the bile samples showing relatively high signal intensities on the T{sub 1}-weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T{sub 1}-weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  15. A study of the minimum number of slices required for quantification of pulmonary emphysema by computed tomography

    International Nuclear Information System (INIS)

    Hitsuda, Yutaka; Igishi, Tadashi; Kawasaki, Yuji

    2000-01-01

    We attempted to determine the minimum number of slices required for quantification of overall emphysema by computed tomography (CT). Forty-nine patients underwent CT scanning with a 15-mm slice interval, and 13 to 18 slices per patient were obtained. The percentage of low attenuation area (LAA%) per slice was measured with a method that we reported on previously, utilizing a CT program and NIH image. The average LAA% values for 1, 2, 3, and 6 slices evenly spaced through the lungs [LAA% (1), LAA% (2), LAA% (3), and LAA% (6)] were compared with those for all slices [LAA% (All)]. The correlation coefficients for LAA% (1), LAA% (2), LAA% (3), and LAA% (6) with LAA% (All) were 0.961, 0.981, 0.993, and 0.997, respectively. Mean differences ±SD were -3.20±4.21%, -2.32±3.00, -0.20±1.84, and -0.16±1.26, respectively. From these results, we concluded that overall emphysema can be quantified by using at least three slices: one each of the upper, middle, and lower lung. (author)

  16. GABAergic Control of Nigrostriatal and Mesolimbic Dopamine in the Rat Brain

    Directory of Open Access Journals (Sweden)

    Susanne Nikolaus

    2018-03-01

    Full Text Available Purpose: The present study assessed the effects of the GABAA receptor (R agonist muscimol (MUS, and the GABAAR antagonist bicuculline (BIC on neocortical and subcortical radioligand binding to dopamine D2/3Rs in relation to motor and exploratory behaviors in the rat.Methods: D2/3R binding was measured with small animal SPECT in baseline and after challenge with either 1 mg/kg MUS or 1 mg/kg BIC, using [123I]IBZM as radioligand. Motor/exploratory behaviors were assessed for 30 min in an open field prior to radioligand administration. Anatomical information was gained with a dedicated small animal MRI tomograph. Based on the Paxinos rat brain atlas, regions of interest were defined on SPECT-MRI overlays. Estimations of the binding potentials in baseline and after challenges were obtained by computing ratios of the specifically bound compartments to the cerebellar reference region.Results: After MUS, D2/3R binding was significantly reduced in caudateputamen, nucleus accumbens, thalamus, substania nigra/ventral tegmental area, and posterior hippocampus relative to baseline (0.005 ≤ p ≤ 0.012. In all these areas, except for the thalamus, D2/3R binding was negatively correlated with grooming in the first half and positively correlated with various motor/exploratory behaviors in the second half of the testing session. After BIC, D2/3R binding was significantly elevated in caudateputamen (p = 0.022 and thalamus (p = 0.047 relative to baseline. D2/3R binding in caudateputamen and thalamus was correlated negatively with sitting duration and sitting frequency and positively with motor/exploratory behaviors in the first half of the testing time.Conclusions: Findings indicate direct GABAergic control over nigrostriatal and mesolimbic dopamine levels in relation to behavioral action. This may be of relevance for neuropsychiatric conditions such as anxiety disorder and schizophrenia, which are characterized by both dopaminergic and GABAergic dysfunction.

  17. Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method

    International Nuclear Information System (INIS)

    Schumann, Stefan; Burcza, Boris; Guttmann, Josef; Haberthür, Christoph; Lichtwarck-Aschoff, Michael

    2009-01-01

    In the clinical situation and in most research work, the analysis of respiratory system mechanics is limited to the estimation of single-value compliances during static or quasi-static conditions. In contrast, our SLICE method analyses intratidal nonlinearity under the dynamic conditions of mechanical ventilation by calculating compliance and resistance for six conjoined volume portions (slices) of the pressure–volume loop by multiple linear regression analysis. With the gliding-SLICE method we present a new approach to determine continuous intratidal nonlinear compliance. The performance of the gliding-SLICE method was tested both in computer simulations and in a physical model of the lung, both simulating different intratidal compliance profiles. Compared to the original SLICE method, the gliding-SLICE method resulted in smaller errors when calculating the compliance or pressure course (all p 2 O s L −1 to 0.8 ± 0.3 cmH 2 O s L −1 (mathematical model) and from 7.2 ± 3.9 cmH 2 O s L −1 to 0.4 ± 0.2 cmH 2 O s L −1 (physical model) (all p < 0.001). We conclude that the new gliding-SLICE method allows detailed assessment of intratidal nonlinear respiratory system mechanics without discontinuity error

  18. Industrial application of an antilisterial strain of Lactobacillus sakei as a protective culture and its effect on the sensory acceptability of cooked, sliced, vacuum-packaged meats.

    Science.gov (United States)

    Bredholt, S; Nesbakken, T; Holck, A

    2001-06-15

    The application of a protective lactic acid bacterium (LAB) during the commercial production of cooked meat products is described. The LAB, a strain of Lactobacillus sakei, was previously isolated from cooked ham and inhibited growth of Listeria monocytogenes and Escherichia coli O157:H7 in this product. L. sakei was applied to the cooked products at a concentration of 10(5)-10(6) cfu/g immediately before slicing and vacuum-packaging using a hand-operated spraying bottle. The LAB strain inhibited growth of 10(3) cfu/g of a cocktail of three rifampicin resistant mutant L. monocytogenes strains both at 8 degrees C and 4 degrees C. Consumer acceptance tests of cooked ham and of servelat sausage, a Norwegian non-fermented cooked meat sausage, showed that control and inoculated products were equally acceptable. The products were still acceptable after storage for 28 days at 4 degrees C and, after opening the packages, for a further 5 days at 4 degrees C. The findings presented here confirm that the L. sakei strain is suitable for use as a protective culture and may technically easily be implemented in the commercial production of cooked meat products.

  19. Performance evaluation of a 64-slice CT system with z-flying focal spot.

    Science.gov (United States)

    Flohr, T; Stierstorfer, K; Raupach, R; Ulzheimer, S; Bruder, H

    2004-12-01

    The meanwhile established generation of 16-slice CT systems enables routine sub-millimeter imaging at short breath-hold times. Clinical progress in the development of multidetector row CT (MDCT) technology beyond 16 slices can more likely be expected from further improvement in spatial and temporal resolution rather than from a mere increase in the speed of volume coverage. We present an evaluation of a recently introduced 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany), which uses a periodic motion of the focal spot in longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. This technique acquires 64 overlapping 0.6 mm slices per rotation. The sampling scheme corresponds to that of a 64 x 0.3 mm detector, with the goal of improved longitudinal resolution and reduced spiral artifacts. After an introduction to the detector design, we discuss the basics of z-flying focal spot technology (z-Sharp). We present phantom and specimen scans for performance evaluation. The measured full width at half maximum (FWHM) of the thinnest spiral slice is 0.65 mm. All spiral slice widths are almost independent of the pitch, with deviations of less than 0.1 mm from the nominal value. Using a high-resolution bar pattern phantom (CATPHAN, Phantom Laboratories, Salem, NY), the longitudinal resolution can be demonstrated to be up to 15 lp/cm at the isocenter independent of the pitch, corresponding to a bar diameter of 0.33 mm. Longitudinal resolution is only slightly degraded for off-center locations. At a distance of 100 mm from the isocenter, 14 lp/cm can be resolved in the z-direction, corresponding to a bar diameter of 0.36 mm. Spiral "windmill" artifacts presenting as hyper- and hypodense structures around osseous edges are effectively reduced by the z-flying focal spot technique. Cardiac scanning benefits from the short gantry rotation time of 0.33 s, providing up to 83 ms temporal resolution with 2-segment ECG

  20. Tumor slices as a model to evaluate doxorubicin in vitro treatment and expression of trios of genes PRSS11, MTSS1, CLPTM1 and PRSS11, MTSS1, SMYD2 in canine mammary gland cancer

    Directory of Open Access Journals (Sweden)

    Patrão Diogo FC

    2008-07-01

    Full Text Available Abstract Background In women with breast cancer submitted to neoadjuvant chemotherapy based in doxorubicin, tumor expression of groups of three genes (PRSS11, MTSS1, CLPTM1 and PRSS11, MTSS1, SMYD2 have classified them as responsive or resistant. We have investigated whether expression of these trios of genes could predict mammary carcinoma response in dogs and whether tumor slices, which maintain epithelial-mesenchymal interactions, could be used to evaluate drug response in vitro. Methods Tumors from 38 dogs were sliced and cultured with or without doxorubicin 1 μM for 24 h. Tumor cells were counted by two observers to establish a percentage variation in cell number, between slices. Based on these results, a reduction in cell number between treated and control samples ≥ 21.7%, arbitrarily classified samples, as drug responsive. Tumor expression of PRSS11, MTSS1, CLPTM1 and SMYD2, was evaluated by real time PCR. Relative expression results were then transformed to their natural logarithm values, which were spatially disposed according to the expression of trios of genes, comprising PRSS11, MTSS1, CLPTM1 and PRSS11, MTSS1, SMYD2. Fisher linear discrimination test was used to generate a separation plane between responsive and non-responsive tumors. Results Culture of tumor slices for 24 h was feasible. Nine samples were considered responsive and 29 non-responsive to doxorubicin, considering the pre-established cut-off value of cell number reduction ≥ 21.7%, between doxorubicin treated and control samples. Relative gene expression was evaluated and tumor samples were then spatially distributed according to the expression of the trios of genes: PRSS11, MTSS1, CLPTM1 and PRSS11, MTSS1, SMYD2. A separation plane was generated. However, no clear separation between responsive and non-responsive samples could be observed. Conclusion Three-dimensional distribution of samples according to the expression of the trios of genes PRSS11, MTSS1, CLPTM1 and

  1. Automatic slice identification in 3D medical images with a ConvNet regressor

    NARCIS (Netherlands)

    de Vos, Bob D.; Viergever, Max A.; de Jong, Pim A.; Išgum, Ivana

    2016-01-01

    Identification of anatomical regions of interest is a prerequisite in many medical image analysis tasks. We propose a method that automatically identifies a slice of interest (SOI) in 3D images with a convolutional neural network (ConvNet) regressor. In 150 chest CT scans two reference slices were

  2. Fluidized bed drying characteristics and modeling of ginger ( zingiber officinale) slices

    Science.gov (United States)

    Parlak, Nezaket

    2015-08-01

    In this study fluidized bed drying characteristics of ginger have been investigated. The effects of the fluidizing air temperature, velocity, humidity and bed height on the drying performance of ginger slices have been found. The experimental moisture loss data of ginger slices has been fitted to the eight thin layer drying models. Two-term model drying model has shown a better fit to the experimental data with R2 of 0.998 as compared to others.

  3. Drying of carrot slices in a triple pass solar dryer

    Directory of Open Access Journals (Sweden)

    Seshachalam Kesavan

    2017-01-01

    Full Text Available An indirect triple pass forced convection solar dryer was developed and its performance was evaluated for drying of carrot slices. The drying experiments were carried out under the meteorological conditions of Coimbatore city in India during the year 2016. The experimental set-up consists of a blower, triple pass packed bed air collector (using sand with wire mesh absorber plate, and a drying chamber. The air mass flow rate was optimized to 0.062 kg/s. The initial moisture content of the carrot slices was reduced from 87.5% (on wet basis to the final moisture content of 10% (wet basis in 6 h duration. The thin layer drying characteristics were analyzed using twelve mathematical models available in open literature. The results showed that the pick-up efficiency of the dryer was varied in the range between 14 and 43% with an average air collector thermal efficiency of 44% during the experimentation. The drying characteristics of carrot slices was predicted with good degree of accuracy using Wang and Singh drying model.

  4. Measures of large-scale structure in the CfA redshift survey slices

    International Nuclear Information System (INIS)

    De Lapparent, V.; Geller, M.J.; Huchra, J.P.

    1991-01-01

    Variations of the counts-in-cells with cell size are used here to define two statistical measures of large-scale clustering in three 6 deg slices of the CfA redshift survey. A percolation criterion is used to estimate the filling factor which measures the fraction of the total volume in the survey occupied by the large-scale structures. For the full 18 deg slice of the CfA redshift survey, f is about 0.25 + or - 0.05. After removing groups with more than five members from two of the slices, variations of the counts in occupied cells with cell size have a power-law behavior with a slope beta about 2.2 on scales from 1-10/h Mpc. Application of both this statistic and the percolation analysis to simulations suggests that a network of two-dimensional structures is a better description of the geometry of the clustering in the CfA slices than a network of one-dimensional structures. Counts-in-cells are also used to estimate at 0.3 galaxy h-squared/Mpc the average galaxy surface density in sheets like the Great Wall. 46 refs

  5. Contamination of knives and graters by bacterial foodborne pathogens during slicing and grating of produce.

    Science.gov (United States)

    Erickson, Marilyn C; Liao, Jean; Cannon, Jennifer L; Ortega, Ynes R

    2015-12-01

    Poor hygiene and improper food preparation practices in consumers' homes have previously been demonstrated as contributing to foodborne diseases. To address potential cross-contamination by kitchen utensils in the home, a series of studies was conducted to determine the extent to which the use of a knife or grater on fresh produce would lead to the utensil's contamination with Escherichia coli O157:H7 or Salmonella enterica. When shredding inoculated carrots (ca. 5.3 log CFU/carrot), all graters became contaminated and the number of E. coli O157:H7 present on the utensil was significantly greater than Salmonella (p Contamination of knives after slicing inoculated produce (4.9-5.4 log CFU/produce item) could only be detected by enrichment culture. After slicing tomatoes, honeydew melons, strawberries, cucumbers, and cantaloupes, the average prevalence of knife contamination by the two pathogens was 43%, 17%, 15%, 7%, and 3%, respectively. No significant increase in the incidence or level of contamination occurred on the utensils when residues were present (p > 0.05); however, subsequent contamination of 7 produce items processed with the contaminated utensils did occur. These results highlight the necessity of proper sanitization of these utensils when used in preparation of raw produce. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. The physiology of rodent beta-cells in pancreas slices.

    Science.gov (United States)

    Rupnik, M

    2009-01-01

    Beta-cells in pancreatic islets form complex syncytia. Sufficient cell-to-cell electrical coupling seems to ensure coordinated depolarization pattern and insulin release that can be further modulated by rich innervation. The complex structure and coordinated action develop after birth during fast proliferation of the endocrine tissue. These emergent properties can be lost due to various reasons later in life and can lead to glucose intolerance and diabetes mellitus. Pancreas slice is a novel method of choice to study the physiology of beta-cells still embedded in their normal cellulo-social context. I present major advantages, list drawbacks and provide an overview on recent advances in our understanding of the physiology of beta-cells using the pancreas slice approach.

  7. Mis-estimation and bias of hyperpolarized apparent diffusion coefficient measurements due to slice profile effects.

    Science.gov (United States)

    Gordon, Jeremy W; Milshteyn, Eugene; Marco-Rius, Irene; Ohliger, Michael; Vigneron, Daniel B; Larson, Peder E Z

    2017-09-01

    The purpose of this work was to explore the impact of slice profile effects on apparent diffusion coefficient (ADC) mapping of hyperpolarized (HP) substrates. Slice profile effects were simulated using a Gaussian radiofrequency (RF) pulse with a variety of flip angle schedules and b-value ordering schemes. A long T 1 water phantom was used to validate the simulation results, and ADC mapping of HP [ 13 C, 15 N 2 ]urea was performed on the murine liver to assess these effects in vivo. Slice profile effects result in excess signal after repeated RF pulses, causing bias in HP measurements. The largest error occurs for metabolites with small ADCs, resulting in up to 10-fold overestimation for metabolites that are in more-restricted environments. A mixed b-value scheme substantially reduces this bias, whereas scaling the slice-select gradient can mitigate it completely. In vivo, the liver ADC of hyperpolarized [ 13 C, 15 N 2 ]urea is nearly 70% lower (0.99 ± 0.22 vs 1.69 ± 0.21 × 10 -3 mm 2 /s) when slice-select gradient scaling is used. Slice profile effects can lead to bias in HP ADC measurements. A mixed b-value ordering scheme can reduce this bias compared to sequential b-value ordering. Slice-select gradient scaling can also correct for this deviation, minimizing bias and providing more-precise ADC measurements of HP substrates. Magn Reson Med 78:1087-1092, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Interaction between subclinical doses of the Parkinson's disease associated gene, α-synuclein, and the pesticide, rotenone, precipitates motor dysfunction and nigrostriatal neurodegeneration in rats.

    Science.gov (United States)

    Naughton, Carol; O'Toole, Daniel; Kirik, Deniz; Dowd, Eilís

    2017-01-01

    In most patients, Parkinson's disease is thought to emerge after a lifetime of exposure to, and interaction between, various genetic and environmental risk factors. One of the key genetic factors linked to this condition is α-synuclein, and the α-synuclein protein is pathologically associated with idiopathic cases. However, α-synuclein pathology is also present in presymptomatic, clinically "normal" individuals suggesting that environmental factors, such as Parkinson's disease-linked agricultural pesticides, may be required to precipitate Parkinson's disease in these individuals. In this context, the aim of this study was to assess the behavioural and neuropathological impact of exposing rats with a subclinical load of α-synuclein to subclinical doses of the organic pesticide, rotenone. Rats were randomly assigned to two groups for intra-nigral infusion of AAV 2/5- GFP or AAV 2/5 -α-synuclein. Post viral motor function was assessed at 8, 10 and 12 weeks in the Corridor, Stepping and Whisker tests of lateralised motor function. At week 12, animals were performance-matched to receive a subsequent intra-striatal challenge of the organic pesticide rotenone (or its vehicle) to yield four final groups (Control, Rotenone, AAV 2/5 -α-synuclein and Combined). Behavioural testing resumed one week after rotenone surgery and continued for 5 weeks. We found that, when administered alone, neither intra-nigral AAV-α-synuclein nor intra-striatal rotenone caused sufficient nigrostriatal neurodegeneration to induce a significant motor impairment in their own right. However, when these were administered sequentially to the same rats, the interaction between the two Parkinsonian challenges significantly exacerbated nigrostriatal neurodegeneration which precipitated a pronounced impairment in motor function. These results indicate that exposing rats with a subclinical α-synuclein-induced pathology to the pesticide, rotenone, profoundly exacerbates their Parkinsonian

  9. Effect of simultaneous infrared dry-blanching and dehydration on quality characteristics of carrot slices

    Science.gov (United States)

    This study investigated the effects of various processing parameters on carrot slices exposed to infrared (IR) radiation heating for achieving simultaneous infrared dry-blanching and dehydration (SIRDBD). The investigated parameters were product surface temperature, slice thickness and processing ti...

  10. Mathematical modeling of hot air/electrohydrodynamic (EHD) drying kinetics of mushroom slices

    International Nuclear Information System (INIS)

    Taghian Dinani, Somayeh; Hamdami, Nasser; Shahedi, Mohammad; Havet, Michel

    2014-01-01

    Highlights: • Hot air/EHD drying behavior of thin layer mushroom slices was evaluated. • A new empirical model was proposed for drying kinetics modeling of mushroom slices. • The new model presents excellent predictions for hot air/EHD drying of mushroom. - Abstract: Researches about mathematical modeling of electrohydrodynamic (EHD) drying are rare. In this study, hot air combined with electrohydrodynamic (EHD) drying behavior of thin layer mushroom slices was evaluated in a laboratory scale dryer at voltages of 17, 19, and 21 kV and electrode gaps of 5, 6, and 7 cm. The drying curves were fitted to ten different mathematical models (Newton, Page, Modified Page, Henderson and Pabis, Logarithmic, Two-term exponential, Midilli and Kucuk, Wang and Singh, Weibull and Parabolic models) and a proposed new empirical model to select a suitable drying equation for drying mushroom slices in a hot air combined with EHD dryer. Coefficients of the models were determined by non-linear regression analysis and the models were compared based on their coefficient of determination (R 2 ), sum of square errors (SSE) and root mean square error (RMSE) between experimental and predicted moisture ratios. According to the results, the proposed model that contains only three parameters provided the best fit with the experimental data. It was closely followed by the Midilli and Kucuk model that contains four parameters. Therefore, the proposed model can present comfortable usage and excellent predictions for the moisture content changes of mushroom slices in the hot air combined with EHD drying system

  11. Prolonged life of human acute hippocampal slices from temporal lobe epilepsy surgery

    DEFF Research Database (Denmark)

    Wickham, J; Brödjegård, N G; Vighagen, R

    2018-01-01

    Resected hippocampal tissue from patients with drug-resistant epilepsy presents a unique possibility to test novel treatment strategies directly in target tissue. The post-resection time for testing and analysis however is normally limited. Acute tissue slices allow for electrophysiological...... granule whole-cell recordings, can be consistently induced in these slices, underlying the usefulness of this methodology for testing and/or validating novel treatment strategies for epilepsy....

  12. Time-space modal logic for verification of bit-slice circuits

    Science.gov (United States)

    Hiraishi, Hiromi

    1996-03-01

    The major goal of this paper is to propose a new modal logic aiming at formal verification of bit-slice circuits. The new logic is called as time-space modal logic and its major feature is that it can handle two transition relations: one for time transition and the other for space transition. As for a verification algorithm, a symbolic model checking algorithm of the new logic is shown. This could be applicable to verification of bit-slice microprocessor of infinite bit width and 1D systolic array of infinite length. A simple benchmark result shows the effectiveness of the proposed approach.

  13. Intersection-based registration of slice stacks to form 3D images of the human fetal brain

    DEFF Research Database (Denmark)

    Kim, Kio; Hansen, Mads Fogtmann; Habas, Piotr

    2008-01-01

    Clinical fetal MR imaging of the brain commonly makes use of fast 2D acquisitions of multiple sets of approximately orthogonal 2D slices. We and others have previously proposed an iterative slice-to-volume registration process to recover a geometrically consistent 3D image. However......, these approaches depend on a 3D volume reconstruction step during the slice alignment. This is both computationally expensive and makes the convergence of the registration process poorly defined. In this paper our key contribution is a new approach which considers the collective alignment of all slices directly...... of the approach applied to simulated data and clinically acquired fetal images....

  14. Evaluation of solitary pulmonary metastasis of extrathoracic tumor with thin-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro; Nomura, Ikuo; Noda, Kazumasa; Yamagata, Tatushi; Tajiri, Michihiko; Ishibashi, Makoto; Kameda, Youichi [Kanagawa Cancer Center, Yokohama (Japan)

    1995-10-01

    Thin-slice computed tomography (CT) images were compared with pathological findings in 9 specimens of solitary pulmonary nodules, which had been pathologically diagnosed as pulmonary metastasis of extrathoracic tumor. The thin-slice CT images were 2 mm-thick images reconstructed using a TCT-900S, HELIX (Toshiba, Tokyo) and examined at two different window and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT images. According to the image findings, the internal structure was of the solid-density type in every case, and the margin showed spiculation in 22%, notching in 67% and pleural indentation in 89%. Regarding the relationship between the pulmonary vessels and tumors, plural vascular involvement was revealed in every case. Thus, it was difficult to distinguish solitary pulmonary metastasis of extrathoracic tumor from primary lung cancer based on the thin-slice CT images. For some solitary pulmonary metastasis of extrathoracic tumor, a comprehensive diagnostic approach taking both the anamnesis and pathological findings into consideration was required. (author).

  15. The measurement of the nigrostriatal dopaminergic function and glucose metabolism in patients with movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Shima, Fumio; Kato, Motohiro (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-12-01

    The nigrostriatal dopaminergic function and glucose metabolism were evaluated in 34 patients with various movement disorders by using positron emission tomography with [sup 18]F-Dopa and [sup 18]F-FDG respectively. The [sup 18]F-Dopa uptake in the striatum (the caudate head and the putamen) decreased in patients with Parkinson's disease but was relatively unaffected in the caudate. The cerebral glucose metabolism was normal in patients with Parkinson's disease. The [sup 18]F-Dopa uptake in the striatum also decreased in cases of atypical parkinsonism and in cases of progressive supranuclear palsy, but there was no difference in the uptake between the caudate and the putamen. The glucose metabolism decreased in the cerebral hemisphere including the striatum; this finding was also different from those of Parkinson's disease. A normal [sup 18]F-Dopa uptake in the striatum with a markedly decreased striatal glucose metabolism and a mildly decreased cortical glucose metabolism was observed in cases of Huntington's disease and Wilson's disease. The [sup 18]F-Dopa uptake in the striatum increased and the glucose metabolism was normal in cases of idiopathic dystonia. Various patterns of [sup 18]F-Dopa uptake and glucose metabolism were thus observed in the various movement disorders. These results suggest that the measurements of the [sup 18]F-Dopa uptake and the cerebral glucose metabolism would be useful for the evaluation of the striatal function in various movement disorders. (author).

  16. The measurement of the nigrostriatal dopaminergic function and glucose metabolism in patients with movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Shima, Fumio; Kato, Motohiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1992-12-01

    The nigrostriatal dopaminergic function and glucose metabolism were evaluated in 34 patients with various movement disorders by using positron emission tomography with [sup 18]F-Dopa and [sup 18]F-FDG respectively. The [sup 18]F-Dopa uptake in the striatum (the caudate head and the putamen) decreased in patients with Parkinson's disease but was relatively unaffected in the caudate. The cerebral glucose metabolism was normal in patients with Parkinson's disease. The [sup 18]F-Dopa uptake in the striatum also decreased in cases of atypical parkinsonism and in cases of progressive supranuclear palsy, but there was no difference in the uptake between the caudate and the putamen. The glucose metabolism decreased in the cerebral hemisphere including the striatum; this finding was also different from those of Parkinson's disease. A normal [sup 18]F-Dopa uptake in the striatum with a markedly decreased striatal glucose metabolism and a mildly decreased cortical glucose metabolism was observed in cases of Huntington's disease and Wilson's disease. The [sup 18]F-Dopa uptake in the striatum increased and the glucose metabolism was normal in cases of idiopathic dystonia. Various patterns of [sup 18]F-Dopa uptake and glucose metabolism were thus observed in the various movement disorders. These results suggest that the measurements of the [sup 18]F-Dopa uptake and the cerebral glucose metabolism would be useful for the evaluation of the striatal function in various movement disorders. (author).

  17. A Novel Approach for Transmission of 56 Gbit/s NRZ Signal in Access Network Using Spectrum Slicing Technique

    DEFF Research Database (Denmark)

    Spolitis, S.; Vegas Olmos, Juan José; Bobrovs, V.

    2013-01-01

    We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time.......We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time....

  18. Abscisic Acid accumulation in spinach leaf slices in the presence of penetrating and nonpenetrating solutes.

    Science.gov (United States)

    Creelman, R A; Zeevaart, J A

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation.When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO(3), 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage).

  19. Software framework developed for the slice test of the ATLAS endcap muon trigger system

    CERN Document Server

    Komatsu, S; Ishida, Y; Tanaka, K; Hasuko, K; Kano, H; Matsumoto, Y; Yakamura, Y; Sakamoto, H; Ikeno, M; Nakayoshi, K; Sasaki, O; Yasu, Y; Hasegawa, Y; Totsuka, M; Tsuji, S; Maeno, T; Ichimiya, R; Kurashige, H

    2002-01-01

    A sliced system test of the ATLAS end cap muon level 1 trigger system has been done in 2001 and 2002 separately. We have developed an own software framework for property and run controls for the slice test in 2001. The system is described in C++ throughout. The multi-PC control system is accomplished using the CORBA system. We have then restructured the software system on top of the ATLAS online software framework, and used this one for the slice test in 2002. In this report we discuss two systems in detail with emphasizing the module property configuration and run control. (8 refs).

  20. Evaluation of methylmercury biotransformation using rat liver slices

    Energy Technology Data Exchange (ETDEWEB)

    Yasutake, A. [Biochemistry Section, National Inst. for Minamata Disease, Minamata, Kumamoto (Japan); Hirayama, K. [Kumamoto University College of Medical Science, Kuhonji (Japan)

    2001-09-01

    To examine the demethylation reaction of methylmercury (MeHg) in rat liver, slices prepared from MeHg-treated rats were incubated in L-15 medium under 95% O{sub 2}/5% CO{sub 2} atmosphere. During the incubation, the amount of inorganic Hg in the slices markedly increased in a time-dependent manner, although the concentration of total Hg remained unchanged. Since the C-Hg bond in MeHg was demonstrated to be cleaved by the action of some reactive oxygen species, the effects on MeHg demethylation of several reagents that could modify reactive oxygen production were examined in the present system. Methylviologen was found to be an effective enhancer of the demethylation reaction with only a minor effect on lipid peroxidation. On the other hand, ferrous ion added to the medium showed no effect on demethylation in the presence or absence of methylviologen, although lipid peroxide levels were increased significantly by ferrous ion. Similarly, deferoxamine mesylate, which effectively suppressed the increase in lipid peroxide levels, also had no effect on demethylation. Furthermore, hydroxy radical scavengers, such as mannitol and dimethylsulfoxide, had no effect on inorganic Hg production. Rotenone, an inhibitor of complex I in the mitochondrial electron transport system, increased levels of both inorganic Hg and lipid peroxide. However, other inhibitors, such as antimycin A, myxothiazole and NaCN, significantly suppressed the demethylation reaction. Cell fractionation of the MeHg-treated rat liver revealed that the ratio of inorganic Hg to total Hg was highest in the mitochondrial fraction. Furthermore, superoxide anion could degrade MeHg in an organic solvent but not in water. These results suggested that the demethylation of MeHg by the liver slice would proceed with the aid of superoxide anion produced in the electron transfer system at the hydrophobic mitochondrial inner membrane. Furthermore, the involvement of hydroxy radicals, which have been demonstrated to be

  1. Mixed time slicing in path integral simulations

    International Nuclear Information System (INIS)

    Steele, Ryan P.; Zwickl, Jill; Shushkov, Philip; Tully, John C.

    2011-01-01

    A simple and efficient scheme is presented for using different time slices for different degrees of freedom in path integral calculations. This method bridges the gap between full quantization and the standard mixed quantum-classical (MQC) scheme and, therefore, still provides quantum mechanical effects in the less-quantized variables. Underlying the algorithm is the notion that time slices (beads) may be 'collapsed' in a manner that preserves quantization in the less quantum mechanical degrees of freedom. The method is shown to be analogous to multiple-time step integration techniques in classical molecular dynamics. The algorithm and its associated error are demonstrated on model systems containing coupled high- and low-frequency modes; results indicate that convergence of quantum mechanical observables can be achieved with disparate bead numbers in the different modes. Cost estimates indicate that this procedure, much like the MQC method, is most efficient for only a relatively few quantum mechanical degrees of freedom, such as proton transfer. In this regime, however, the cost of a fully quantum mechanical simulation is determined by the quantization of the least quantum mechanical degrees of freedom.

  2. Progress on the Femto-Slicing Project at the Synchrotron SOLEIL

    International Nuclear Information System (INIS)

    Prigent, P; Hollander, Ph; Labat, M; Couprie, M E; Marlats, J L; Laulhé, C; Luning, J; Moreno, T; Morin, P; Nadji, A; Polack, F; Ravy, S; Silly, M; Sirotti, F

    2013-01-01

    The aim of the Femto-Slicing project at SOLEIL is to generate 100 fs X-rays pulses on two beamlines, CRISTAL and TEMPO, for pump-probe experiments in the hard and soft X-rays regions. Two fs lasers are currently in operation on TEMPO and CRISTAL for pump-probe experiments on the ps time scale enabling time resolved photoemission and photodiffraction studies. The Femto-Slicing project is based on the fs laser of the CRISTAL beamline, which can be adjusted to deliver 3 mJ pulses of 30 fs duration at 2.5 kHz. The laser beam will be separated in three branches: one delivering about 2 mJ to the modulator Wiggler and the other ones delivering the remaining energy to the TEMPO and CRISTAL experiments. This layout will yield natural synchronization between IR laser pump and X-ray probe pulses, only affected by jitter associated with beam transport. In this paper, we present the current status of the Femto-Slicing project at SOLEIL, with particular emphasis on the expected performance, and the design and construction of the laser beam transport and the diagnostics implementation.

  3. Indole and synthetic derivative activate chaperone expression to reduce polyQ aggregation in SCA17 neuronal cell and slice culture models

    Directory of Open Access Journals (Sweden)

    Kung PJ

    2014-10-01

    Full Text Available Pin-Jui Kung,1,* Yu-Chen Tao,1,* Ho-Chiang Hsu,1 Wan-Ling Chen,1 Te-Hsien Lin,1 Donala Janreddy,2 Ching-Fa Yao,2 Kuo-Hsuan Chang,3 Jung-Yaw Lin,1 Ming-Tsan Su,1 Chung-Hsin Wu,1 Guey-Jen Lee-Chen,1 Hsiu-Mei Hsieh-Li1 1Department of Life Science, 2Department of Chemistry, National Taiwan Normal University, Taipei, Taiwan; 3Department of Neurology, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taipei, Taiwan *These authors contributed equally to this work Abstract: In spinocerebellar ataxia type 17 (SCA17, the expansion of a translated CAG repeat in the TATA box binding protein (TBP gene results in a long polyglutamine (polyQ tract in the TBP protein, leading to intracellular accumulation of aggregated TBP and cell death. The molecular chaperones act in preventing protein aggregation to ameliorate downstream harmful events. In this study, we used Tet-On SH-SY5Y cells with inducible SCA17 TBP/Q79-green fluorescent protein (GFP expression to test indole and synthetic derivative NC001-8 for neuroprotection. We found that indole and NC001-8 up-regulated chaperone expression to reduce polyQ aggregation in neuronal differentiated TBP/Q79 cells. The effects on promoting neurite outgrowth and on reduction of aggregation on Purkinje cells were also confirmed with cerebellar primary and slice cultures of SCA17 transgenic mice. Our results demonstrate how indole and derivative NC001-8 reduce polyQ aggregation to support their therapeutic potentials in SCA17 treatment. Keywords: spinocerebellar ataxia type 17, TATA box binding protein, polyQ aggregation, indole and derivative, therapeutics

  4. Fourier-based approach to interpolation in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2001-01-01

    It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal direction and because the exploitation of the redundancy of fanbeam data acquired over 360 degree sign to generate additional longitudinal samples does not automatically eliminate the aliasing. In this paper we demonstrate that for pitches near 1 or lower, the redundant fanbeam data, when used properly, can provide sufficient information to satisfy a generalized sampling theorem and thus to eliminate aliasing. We develop and evaluate a Fourier-based algorithm, called 180FT, that accomplishes this. As background we present a second Fourier-based approach, called 360FT, that makes use only of the directly measured data. Both Fourier-based approaches exploit the fast Fourier transform and the Fourier shift theorem to generate from the helical projection data a set of fanbeam sinograms corresponding to equispaced transverse slices. Slice-by-slice reconstruction is then performed by use of two-dimensional fanbeam algorithms. The proposed approaches are compared to their counterparts based on the use of linear interpolation - the 360LI and 180LI approaches. The aliasing suppression property of the 180FT approach is a clear advantage of the approach and represents a step toward the desirable goal of achieving uniform longitudinal resolution properties in reconstructed helical CT volumes

  5. 9-Cis retinoic acid protects against methamphetamine-induced neurotoxicity in nigrostriatal dopamine neurons.

    Science.gov (United States)

    Reiner, David J; Yu, Seong-Jin; Shen, Hui; He, Yi; Bae, Eunkyung; Wang, Yun

    2014-04-01

    Methamphetamine (MA) is a drug of abuse as well as a dopaminergic neurotoxin. 9-Cis retinoic acid (9cRA), a biologically active derivative of vitamin A, has protective effects against damage caused by H(2)O(2) and oxygen-glucose deprivation in vitro as well as infarction and terminal deoxynucleotidyl transferase-mediated dNTP nick-end labeling (TUNEL) labeling in ischemic brain. The purpose of this study was to examine if there was a protective role for 9cRA against MA toxicity in nigrostriatal dopaminergic neurons. Primary dopaminergic neurons, prepared from rat embryonic ventral mesencephalic tissue, were treated with MA. High doses of MA decreased tyrosine hydroxylase (TH) immunoreactivity while increasing TUNEL labeling. These toxicities were significantly reduced by 9cRA. 9cRA also inhibited the export of Nur77 from nucleus to cytosol, a response that activates apoptosis. The interaction of 9cRA and MA in vivo was next examined in adult rats. 9cRA was delivered intracerebroventricularly; MA was given (5 mg/kg, 4×) one day later. Locomotor behavior was measured 2 days after surgery for a period of 48 h. High doses of MA significantly reduced locomotor activity and TH immunoreactivity in striatum. Administration of 9cRA antagonized these changes. Previous studies have shown that 9cRA can induce bone morphogenetic protein-7 (BMP7) expression and that administration of BMP7 attenuates MA toxicity. We demonstrated that MA treatment significantly reduced BMP7 mRNA expression in nigra. Noggin (a BMP antagonist) antagonized 9cRA-induced behavioral recovery and 9cRA-induced normalization of striatal TH levels. Our data suggest that 9cRA has a protective effect against MA-mediated neurodegeneration in dopaminergic neurons via upregulation of BMP.

  6. Optical microwave filter based on spectral slicing by use of arrayed waveguide gratings.

    Science.gov (United States)

    Pastor, Daniel; Ortega, Beatriz; Capmany, José; Sales, Salvador; Martinez, Alfonso; Muñoz, Pascual

    2003-10-01

    We have experimentally demonstrated a new optical signal processor based on the use of arrayed waveguide gratings. The structure exploits the concept of spectral slicing combined with the use of an optical dispersive medium. The approach presents increased flexibility from previous slicing-based structures in terms of tunability, reconfiguration, and apodization of the samples or coefficients of the transversal optical filter.

  7. An assessment of the number of CT slices necessary to plan breast radiotherapy

    International Nuclear Information System (INIS)

    Vincent, D.; Beckham, W.; Delaney, G.

    1999-01-01

    The aim of this study was to evaluate the number of CT slices required to produce satisfactory dose distribution for tangential field irradiation of the chest wall and breast and to assess correlation of this with the volume of breast tissue treated. We conclude that a single-slice plan is unsatisfactory in providing sufficient information about the dose variation across the treatment volume and that ideally a 3D plan with DVHs should be produced. If the required data is unavailable then a minimum of three slices should be used as an approximation. We also propose a software tool for treatment planning systems, which calculates the percentage of the total PTV having dose outside the ICRU 50 radiation dose distribution homogeneity guideline range

  8. Precision-cut liver slices to investigate responsiveness of deep-sea fish to contaminants at high pressure.

    Science.gov (United States)

    Lemaire, Benjamin; Debier, Cathy; Calderon, Pedro Buc; Thomé, Jean Pierre; Stegeman, John; Mork, Jarle; Rees, Jean François

    2012-09-18

    While deep-sea fish accumulate high levels of persistent organic pollutants (POPs), the toxicity associated with this contamination remains unknown. Indeed, the recurrent collection of moribund individuals precludes experimental studies to investigate POP effects in this fauna. We show that precision-cut liver slices (PCLS), an in vitro tool commonly used in human and rodent toxicology, can overcome such limitation. This technology was applied to individuals of the deep-sea grenadier Coryphaenoides rupestris directly upon retrieval from 530-m depth in Trondheimsfjord (Norway). PCLS remained viable and functional for 15 h when maintained in an appropriate culture media at 4 °C. This allowed experimental exposure of liver slices to the model POP 3-methylcholanthrene (3-MC; 25 μM) at levels of hydrostatic pressure mimicking shallow (0.1 megapascal or MPa) and deep-sea (5-15 MPa; representative of 500-1500 m depth) environments. As in shallow water fish, 3-MC induced the transcription of the detoxification enzyme cytochrome P4501A (CYP1A; a biomarker of exposure to POPs). This induction was diminished at elevated pressure, suggesting a limited responsiveness of C. rupestris toward POPs in its native environment. This very first in vitro toxicological investigation on a deep-sea fish opens the route for understanding pollutants effects in this highly exposed fauna.

  9. Organotypic Culture of Breast Tumor Explants as a Multicellular System for the Screening of Natural Compounds with Antineoplastic Potential

    Directory of Open Access Journals (Sweden)

    Irma Edith Carranza-Torres

    2015-01-01

    Full Text Available Breast cancer is the leading cause of death in women worldwide. The search for novel compounds with antitumor activity, with less adverse effects and higher efficacy, and the development of methods to evaluate their toxicity is an area of ​​intense research. In this study we implemented the preparation and culture of breast tumor explants, which were obtained from precision-cut breast tumor slices. In order to validate the model we are proposing to screen antineoplastic effect of natural compounds, we selected caffeic acid, ursolic acid, and rosmarinic acid. Using the Krumdieck tissue slicer, precision-cut tissue slices were prepared from breast cancer samples; from these slices, 4 mm explants were obtained and incubated with the selected compounds. Viability was assessed by Alamar Blue assay, LDH release, and histopathological criteria. Results showed that the viability of the explants cultured in the presence of paclitaxel (positive control decreased significantly (P<0.05; however, tumor samples responded differently to each compound. When the explants were coincubated with paclitaxel and compounds, a synergic effect was observed. This study shows that ex vivo culture of breast cancer explants offers a suitable alternative model for evaluating natural or synthetic compounds with antitumor properties within the complex microenvironment of the tumor.

  10. 640-slice DVCT multi-dimensionally and dynamically presents changes in bladder volume and urine flow rate

    Science.gov (United States)

    Su, Yunshan; Fang, Kewei; Mao, Chongwen; Xiang, Shutian; Wang, Jin; Li, Yingwen

    2018-01-01

    The present study aimed to explore the application of 640-slice dynamic volume computed tomography (DVCT) to excretory cystography and urethrography. A total of 70 healthy subjects were included in the study. Excretory cystography and urethrography using 640-slice DVCT was conducted to continuously record the motions of the bladder and the proximal female and male urethra. The patients' voiding process was divided into early, early to middle, middle, middle to late, and late voiding phases. The subjects were analyzed using DVCT and conventional CT. The cross-sectional areas of various sections of the male and female urethra were evaluated, and the average urine flow rate was calculated. The 640-slice DVCT technique was used to dynamically observe the urine flow rate and changes in bladder volume at all voiding phases. The urine volume detected by 640-slice DVCT exhibited no significant difference compared with the actual volume, and no significant difference compared with that determined using conventional CT. Furthermore, no significant difference in the volume of the bladder at each phase of the voiding process was detected between 640-slice DVCT and conventional CT. The results indicate that 640-slice DVCT can accurately evaluate the status of the male posterior urethra and female urethra. In conclusion, 640-slice DVCT is able to multi-dimensionally and dynamically present changes in bladder volume and urine flow rate, and could obtain similar results to conventional CT in detecting urine volume, as well as the status of the male posterior urethra and female urethra. PMID:29467853

  11. Tomographic apparatus and method for reconstructing planar slices from non-absorbed radiation

    International Nuclear Information System (INIS)

    1976-01-01

    In a tomographic apparatus and method for reconstructing two-dimensional planar slices from linear projections of non-absorbed radiation useful in the fields of medical radiology, microscopy, and non-destructive testing, a beam of radiation in the shape of a fan is passed through an object lying in the same quasi-plane as the object slice and non-absorbtion thereof is recorded on oppositely-situated detectors aligned with the source of radiation. There is relative rotation between the source-detector configuration and the object within the quasi-plane. Periodic values of the detected radiation are taken, convolved with certain functions, and back-projected to produce a two-dimensional output picture on a visual display illustrating a facsimile of the object slice. A series of two-dimensional pictures obtained simultaneously or serially can be combined to produce a three dimensional portrayal of the entire object

  12. Analysis and classification of commercial ham slice images using directional fractal dimension features.

    Science.gov (United States)

    Mendoza, Fernando; Valous, Nektarios A; Allen, Paul; Kenny, Tony A; Ward, Paddy; Sun, Da-Wen

    2009-02-01

    This paper presents a novel and non-destructive approach to the appearance characterization and classification of commercial pork, turkey and chicken ham slices. Ham slice images were modelled using directional fractal (DF(0°;45°;90°;135°)) dimensions and a minimum distance classifier was adopted to perform the classification task. Also, the role of different colour spaces and the resolution level of the images on DF analysis were investigated. This approach was applied to 480 wafer thin ham slices from four types of hams (120 slices per type): i.e., pork (cooked and smoked), turkey (smoked) and chicken (roasted). DF features were extracted from digitalized intensity images in greyscale, and R, G, B, L(∗), a(∗), b(∗), H, S, and V colour components for three image resolution levels (100%, 50%, and 25%). Simulation results show that in spite of the complexity and high variability in colour and texture appearance, the modelling of ham slice images with DF dimensions allows the capture of differentiating textural features between the four commercial ham types. Independent DF features entail better discrimination than that using the average of four directions. However, DF dimensions reveal a high sensitivity to colour channel, orientation and image resolution for the fractal analysis. The classification accuracy using six DF dimension features (a(90°)(∗),a(135°)(∗),H(0°),H(45°),S(0°),H(90°)) was 93.9% for training data and 82.2% for testing data.

  13. Using a high-speed movie camera to evaluate slice dropping in clinical image interpretation with stack mode viewers.

    Science.gov (United States)

    Yakami, Masahiro; Yamamoto, Akira; Yanagisawa, Morio; Sekiguchi, Hiroyuki; Kubo, Takeshi; Togashi, Kaori

    2013-06-01

    The purpose of this study is to verify objectively the rate of slice omission during paging on picture archiving and communication system (PACS) viewers by recording the images shown on the computer displays of these viewers with a high-speed movie camera. This study was approved by the institutional review board. A sequential number from 1 to 250 was superimposed on each slice of a series of clinical Digital Imaging and Communication in Medicine (DICOM) data. The slices were displayed using several DICOM viewers, including in-house developed freeware and clinical PACS viewers. The freeware viewer and one of the clinical PACS viewers included functions to prevent slice dropping. The series was displayed in stack mode and paged in both automatic and manual paging modes. The display was recorded with a high-speed movie camera and played back at a slow speed to check whether slices were dropped. The paging speeds were also measured. With a paging speed faster than half the refresh rate of the display, some viewers dropped up to 52.4 % of the slices, while other well-designed viewers did not, if used with the correct settings. Slice dropping during paging was objectively confirmed using a high-speed movie camera. To prevent slice dropping, the viewer must be specially designed for the purpose and must be used with the correct settings, or the paging speed must be slower than half of the display refresh rate.

  14. Microfilament Contraction Promotes Rounding of Tunic Slices: An Integumentary Defense System in the Colonial Ascidian Aplidium yamazii.

    Science.gov (United States)

    Hirose, E; Ishii, T

    1995-08-01

    In Aplidium yamazii, when a slice of a live colony (approximately 0.5 mm thick) was incubated in seawater for 12 h, the slice became a round tunic fragment. This tunic rounding was inhibited by freezing of the slices, incubation with Ca2+-Mg2+ -free seawater, or addition of cytochalasin B. Staining of microfilaments in the slices with phalloidin-FITC showed the existence of a cellular network in the tunic. Contraction of this cellular network probably promotes rounding of the tunic slice. In electron microscopic observations, a new tunic cuticle regenerated at the surface of the round tunic fragments; the tunic cuticle did not regenerate in newly sliced specimens nor in specimens in which rounding was experimentally inhibited. Based on these results, an integumentary defense system is proposed in this species as follows. (1) When the colony is wounded externally, contraction of the cellular network promotes tunic contraction around the wound. (2) The wound is almost closed by tunic contraction. (3) Tunic contraction increases the density of the filamentous components of the tunic at the wound, and it may accelerate the regeneration of tunic cuticle there.

  15. Comparison between powder and slices diffraction methods in teeth samples

    Energy Technology Data Exchange (ETDEWEB)

    Colaco, Marcos V.; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (IF/UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada; Porto, Isabel M. [Universidade Estadual de Campinas (FOP/UNICAMP), Piracicaba, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia; Gerlach, Raquel F. [Universidade de Sao Paulo (FORP/USP), Rieirao Preto, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia, Estomatologia e Fisiologia; Costa, Fanny N. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10{sup -1}0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  16. Comparison between powder and slices diffraction methods in teeth samples

    International Nuclear Information System (INIS)

    Colaco, Marcos V.; Barroso, Regina C.; Porto, Isabel M.; Gerlach, Raquel F.; Costa, Fanny N.

    2011-01-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10 -1 0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  17. A Novel Slicing Method for Thin Supercapacitors.

    Science.gov (United States)

    Sun, Hao; Fu, Xuemei; Xie, Songlin; Jiang, Yishu; Guan, Guozhen; Wang, Bingjie; Li, Houpu; Peng, Huisheng

    2016-08-01

    Thin and flexible supercapacitors with low cost and individual variation are fabricated by a new and efficient slicing method. Tunable output voltage and energy can be realized with a high specific capacitance of 248.8 F g(-1) or 150.8 F cm(-3) , which is well maintained before and after bending. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Detecting Psychopathy from Thin Slices of Behavior

    Science.gov (United States)

    Fowler, Katherine A.; Lilienfeld, Scott O.; Patrick, Christopher J.

    2009-01-01

    This study is the first to demonstrate that features of psychopathy can be reliably and validly detected by lay raters from "thin slices" (i.e., small samples) of behavior. Brief excerpts (5 s, 10 s, and 20 s) from interviews with 96 maximum-security inmates were presented in video or audio form or in both modalities combined. Forty raters used…

  19. Slice of a LEP bending magnet

    CERN Multimedia

    This is a slice of a LEP dipole bending magnet, made as a concrete and iron sandwich. The bending field needed in LEP is small (about 1000 Gauss), equivalent to two of the magnets people stick on fridge doors. Because it is very difficult to keep a low field steady, a high field was used in iron plates embedded in concrete. A CERN breakthrough in magnet design, LEP dipoles can be tuned easily and are cheaper than conventional magnets.

  20. Neuropeptide processing in regional brain slices: Effect of conformation and sequence

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.W.; Bijl, W.A.; van Nispen, J.W.; Brendel, K.; Davis, T.P. (Univ. of Arizona, Tucson (USA))

    1990-05-01

    The central enzymatic stability of des-enkephalin-gamma-endorphin and its synthetic analogs (cycloN alpha 6, C delta 11)beta-endorphin-(6-17) and (Pro7, Lys(Ac)9)-beta-endorphin(6-17) was studied in vitro using a newly developed, regionally dissected rat brain slice, time course incubation procedure. Tissue slice viability was estimated as the ability of the brain slice to take up or release gamma-(3H)aminobutyric acid after high K+ stimulation. Results demonstrated stability of uptake/release up to 5 hr of incubation, suggesting tissue viability over this period. The estimated half-life of peptides based on the results obtained in our incubation protocol suggest that the peptides studied are metabolized at different rates in the individual brain regions tested. A good correlation exists between the high enzyme activity of neutral endopeptidase and the rapid degradation of des-enkephalin-gamma-endorphin and (cycloN alpha 6, C delata 11)beta-endorphin-(6-17) in caudate putamen. Proline substitution combined with lysine acetylation appears to improve resistance to enzymatic metabolism in caudate putamen and hypothalamus. However, cyclization of des-enkephalin-gamma-endorphin forming an amide bond between the alpha-NH2 of the N-terminal threonine and the gamma-COOH of glutamic acid did not improve peptide stability in any brain region tested. The present study has shown that the brain slice technique is a valid and unique approach to study neuropeptide metabolism in small, discrete regions of rat brain where peptides, peptidases and receptors are colocalized and that specific structural modifications can improve peptide stability.

  1. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  2. Isoproterenol effects evaluated in heart slices of human and rat in comparison to rat heart in vivo

    International Nuclear Information System (INIS)

    Herrmann, Julia E.; Heale, Jason; Bieraugel, Mike; Ramos, Meg; Fisher, Robyn L.; Vickers, Alison E.M.

    2014-01-01

    Human response to isoproterenol induced cardiac injury was evaluated by gene and protein pathway changes in human heart slices, and compared to rat heart slices and rat heart in vivo. Isoproterenol (10 and 100 μM) altered human and rat heart slice markers of oxidative stress (ATP and GSH) at 24 h. In this in vivo rat study (0.5 mg/kg), serum troponin concentrations increased with lesion severity, minimal to mild necrosis at 24 and 48 h. In the rat and the human heart, isoproterenol altered pathways for apoptosis/necrosis, stress/energy, inflammation, and remodeling/fibrosis. The rat and human heart slices were in an apoptotic phase, while the in vivo rat heart exhibited necrosis histologically and further progression of tissue remodeling. In human heart slices genes for several heat shock 70 kD members were altered, indicative of stress to mitigate apoptosis. The stress response included alterations in energy utilization, fatty acid processing, and the up-regulation of inducible nitric oxide synthase, a marker of increased oxidative stress in both species. Inflammation markers linked with remodeling included IL-1α, Il-1β, IL-6 and TNFα in both species. Tissue remodeling changes in both species included increases in the TIMP proteins, inhibitors of matrix degradation, the gene/protein of IL-4 linked with cardiac fibrosis, and the gene Ccl7 a chemokine that induces collagen synthesis, and Reg3b a growth factor for cardiac repair. This study demonstrates that the initial human heart slice response to isoproterenol cardiac injury results in apoptosis, stress/energy status, inflammation and tissue remodeling at concentrations similar to that in rat heart slices. - Highlights: • Human response to isoproterenol induced cardiac injury evaluated in heart slices. • Isoproterenol altered apoptosis, energy, inflammation and remodeling pathways. • Human model verified by comparison to rat heart slices and rat heart in vivo. • Human and rat respond to isoproterenol

  3. Glucose-stimulated calcium dynamics in islets of Langerhans in acute mouse pancreas tissue slices.

    Directory of Open Access Journals (Sweden)

    Andraž Stožer

    Full Text Available In endocrine cells within islets of Langerhans calcium ions couple cell stimulation to hormone secretion. Since the advent of modern fluorimetry, numerous in vitro studies employing primarily isolated mouse islets have investigated the effects of various secretagogues on cytoplasmic calcium, predominantly in insulin-secreting beta cells. Due to technical limitations, insights of these studies are inherently limited to a rather small subpopulation of outermost cells. The results also seem to depend on various factors, like culture conditions and duration, and are not always easily reconcilable with findings in vivo. The main controversies regard the types of calcium oscillations, presence of calcium waves, and the level of synchronized activity. Here, we set out to combine the in situ acute mouse pancreas tissue slice preparation with noninvasive fluorescent calcium labeling and subsequent confocal laser scanning microscopy to shed new light on the existing controversies utilizing an innovative approach enabling the characterization of responses in many cells from all layers of islets. Our experiments reproducibly showed stable fast calcium oscillations on a sustained plateau rather than slow oscillations as the predominant type of response in acute tissue slices, and that calcium waves are the mechanistic substrate for synchronization of oscillations. We also found indirect evidence that even a large amplitude calcium signal was not sufficient and that metabolic activation was necessary to ensure cell synchronization upon stimulation with glucose. Our novel method helped resolve existing controversies and showed the potential to help answer important physiological questions, making it one of the methods of choice for the foreseeable future.

  4. Differential alteration of the nigrostriatal dopaminergic system in Wilson's disease investigated with [123I]ss-CIT and high-resolution SPET

    International Nuclear Information System (INIS)

    Barthel, H.; Sorger, D.; Kluge, R.; Kuehn, H.-J.; Wagner, A.; Hermann, W.

    2001-01-01

    Wilson's disease (WD) is a copper deposition disorder which can result in a number of extrapyramidal motoric symptoms such as parkinsonism. Therefore, this study was carried out to investigate, for the first time, nigrostriatal dopaminergic function in WD in relation to different courses and severity of the disease. Using high-resolution single-photon emission tomography (SPET) after administration of 2ss-carbomethoxy-3ss-(4[ 123 I]iodophenyl)tropane ([ 123 I]ss-CIT), striatal dopamine transporters (DAT) were imaged in 43 WD patients and a control group of ten subjects. From the SPET images, specific [ 123 I]ss-CIT binding ratios were obtained for the caudate heads, putamina and entire corpus striatum. In addition, to evaluate a putative dissociation between the caudate and putaminal [ 123 I]ss-CIT binding ratios, the ratio between these binding ratios was calculated (CA/PU ratio). The SPET data were compared with clinical data on the course of the disease (CD), the severity of neurological symptoms and the degree of hepatic alteration. Whereas the specific regional [ 123 I]ss-CIT binding ratios in patients with asymptomatic/hepatic CD did not differ from those in the control group (e.g. striatal ratios: 13.4±3.0 vs 11.7±2.8), in patients with neurological CD the ratios were significantly reduced for all striatal substructures (P=0.003 after one-factor ANOVA). For the different subgroups a tendency was detected towards a stepwise decrease in the specific [ 123 I]ss-CIT binding ratios from pseudo-sclerosis CD (9.4±2.3), through pseudo-parkinsonian CD (9.1±2.1) to arrhythmic-hyperkinetic CD (8.5±1.6). However, these group differences reached significance only for the comparison with asymptomatic/hepatic CD (P=0.02). The CA/PU ratio was significantly higher in WD than in the control group (1.30±0.19 vs 1.11±0.08; P=0.003). Severity of neurological symptoms was significantly correlated with all specific regional [ 123 I]ss-CIT binding ratios (r=-0.49 to -0

  5. Abscisic Acid Accumulation in Spinach Leaf Slices in the Presence of Penetrating and Nonpenetrating Solutes 1

    Science.gov (United States)

    Creelman, Robert A.; Zeevaart, Jan A. D.

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation. When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO3, 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage). PMID:16664022

  6. Evaluation of the possibility to use thick slabs of reconstructed outer breast tomosynthesis slice images

    Science.gov (United States)

    Petersson, Hannie; Dustler, Magnus; Tingberg, Anders; Timberg, Pontus

    2016-03-01

    The large image volumes in breast tomosynthesis (BT) have led to large amounts of data and a heavy workload for breast radiologists. The number of slice images can be decreased by combining adjacent image planes (slabbing) but the decrease in depth resolution can considerably affect the detection of lesions. The aim of this work was to assess if thicker slabbing of the outer slice images (where lesions seldom are present) could be a viable alternative in order to reduce the number of slice images in BT image volumes. The suggested slabbing (an image volume with thick outer slabs and thin slices between) were evaluated in two steps. Firstly, a survey of the depth of 65 cancer lesions within the breast was performed to estimate how many lesions would be affected by outer slabs of different thicknesses. Secondly, a selection of 24 lesions was reconstructed with 2, 6 and 10 mm slab thickness to evaluate how the appearance of lesions located in the thicker slabs would be affected. The results show that few malignant breast lesions are located at a depth less than 10 mm from the surface (especially for breast thicknesses of 50 mm and above). Reconstruction of BT volumes with 6 mm slab thickness yields an image quality that is sufficient for lesion detection for a majority of the investigated cases. Together, this indicates that thicker slabbing of the outer slice images is a promising option in order to reduce the number of slice images in BT image volumes.

  7. Slicing Cuts on Food Materials Using Robotic-Controlled Razor Blade

    Directory of Open Access Journals (Sweden)

    Debao Zhou

    2011-01-01

    Full Text Available Cutting operations using blades can arise in a number of industries, for example, food processing industry, in which cheese, fruit and vegetable, even meat, are involved. Certain questions will rise during these works, such as “why pressing-and-slicing cuts use less force than pressing-only cuts” and “how is the influence of the blade cutting-edge on force”. To answer these questions, this research developed a mathematical expression of the cutting stress tensor. Based on the analysis of the stress tensor on the contact surface, the influence of the blade edge-shape and slicing angle on the resultant cutting force were formulated and discussed. These formulations were further verified using experimental results by robotic cutting of potatoes. Through studying the change of the cutting force, the optimal slicing angle can be obtained in terms of maximum feeding distance and minimum cutting force. Based on the blade sharpness properties and the specific materials, the required cutting force can be predicted. These formulation and experimental results explained the basic theory of blade cutting fracture and further provided the support to optimize the cutting mechanism design and to develop the force control algorithms for the automation of blade cutting operations.

  8. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  9. Time-slicing subsystem of the biology small-angle x-ray scattering station at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Stubblefield, F.W.

    1985-11-01

    The time-slicing subsystem of the Biology Small-Angle X-ray Scattering divides the time period during which the data for small-angle x-ray diffraction patterns from biological samples is collected into time slices (or frames). The subsystem, being part of a multiprocessor experiment control and data acquisition system, has its own dedicated processor; it also has special-purpose front-end electronics sufficient to generate the gating and other control signals required to produce a sequence of as many as 256 time slices, measured with a basic time unit of 1 μsec. The electronics also synchronizes with execution of the time slice sequence the application of stimuli to the biological sample, the measurement of voltages generated by the sample, and the application of auxiliary device trigger pulses and routes detector data and auxiliary scaler data into appropriate time-slice-indexed buffers in a large external data memory array. The structure of the entire experiment control and data acquisition system is briefly reviewed. Details of the structure and operation of the time slice subsystem are presented. 7 refs., 5 figs

  10. Effects of metal ions on agonist-stimulated accumulation of inositol phosphates in hippocampal and cortical slices

    International Nuclear Information System (INIS)

    Bonner, M.J.; Tilson, H.A.

    1990-01-01

    [ 3 H]-inositol was incorporated into rat hippocampal or cortical slices. Zinc chloride and three different forms of inorganic lead compounds, lead chloride, lead nitrate, and lead acetate were used to stimulate PI metabolism at concentrations between 10 -15 and 10 -9 M. At these concentrations, these metal ions did not produce any significant stimulation of IP release. In birth hippocampal and cortical slices, carbachol produced equal levels of IP release. Norepinephrine (NE) produced a 10-15% higher stimulation than carbachol. When the metal ions were added to hippocampal slices together with the agonists, there was a general suppression of carbachol- or NE-induced IP release. This general suppression was not observed in cortical slices. These data suggest that the trace metals used inhibit agonist-induced second messenger release in the hippocampus

  11. Microbial growth and sensory quality of dried potato slices irradiated by electrons

    International Nuclear Information System (INIS)

    Kim, Hyun-Jin; Song, Hyeon-Jeong; Song, Kyung-Bin

    2011-01-01

    Electron beam irradiation was applied to secure the microbial safety of dried purple sweet potato. After purple sweet potato slices had been dehydrated with 20% (w/w) maltodextrin solution, the samples were irradiated at doses 2, 4, 6, 8, and 10 kGy and then stored at 20 o C for 60 days. Microbiological data indicated that the populations of total aerobic bacteria and of yeast and molds significantly decreased with increase in irradiation dosage. Specifically, microbial load was reduced by about three log cycles at 6 kGy compared to those of the control. Based on the color measurement of the potato slices, electron beam irradiation treatment did not affect the color quality. Sensory evaluation results also showed that electron beam irradiation did not affect overall sensory scores during storage. These results suggest that electron beam irradiation could be useful for improving microbial safety without impairing the quality of the potato slices during storage.

  12. Exposure (mAs) optimisation of a multi-detector CT protocol for hepatic lesion detection: are thinner slices better?

    International Nuclear Information System (INIS)

    Dobeli, Karen L.; Lewis, Sarah J.; Meikle, Steven R.; Brennan, Patrick C.; Thiele, David L.

    2014-01-01

    The purpose of this work was to determine the exposure-optimised slice thickness for hepatic lesion detection with CT. A phantom containing spheres (diameter 9.5, 4.8 and 2.4mm) with CT density 10 HU below the background (50 HU) was scanned at 125, 100, 75 and 50 mAs. Data were reconstructed at 5-, 3- and 1-mm slice thicknesses. Noise, contrast-to-noise ratio (CNR), area under the curve (AUC) as calculated using receiver operating characteristic analysis and sensitivity representing lesion detection were calculated and compared. Compared with the 125 mAs/5mm slice thickness setting, significant reductions in AUC were found for 75 mAs (P<0.01) and 50 mAs (P<0.05) at 1- and 3-mm thicknesses, respectively; sensitivity for the 9.5-mm sphere was significantly reduced for 75 (P<0.05) and 50 mAs (P<0.01) at 1-mm thickness; sensitivity for the 4.8-mm sphere was significantly lower for 100, 75 and 50 mAs at all three slice thicknesses (P<0.05). The 2.4-mm sphere was rarely detected. At each slice thickness, noise at 100, 75 and 50 mAs exposures was approximately 10, 30 and 50% higher, respectively, than that at 125 mAs exposure. CNRs decreased in an irregular manner with reductions in exposure and slice thickness. This study demonstrated no advantage to using slices below 5mm thickness, and consequently thinner slices are not necessarily better.

  13. Application of 2 mm thin-slice scanning with bone algorithm on conventional CT in diagnosis of the pulmonary diseases

    International Nuclear Information System (INIS)

    Zhang Xianheng; Li Xiuhua; Wang Fenghua

    2004-01-01

    Objective: To evaluate the value of 2 mm thin-slice conventional CT scan with bone algorithm in diagnosis and differential diagnosis in the pulmonary diseases. Methods: In total 135 cases of the pulmonary diseases were routinely scanned by conventional scan, 10 mm per slice, with standard algorithm, then the 2 mm thin-slice scan with bone algorithm was performed at the interested region of the lungs. Result: According to the comparative study of the CT signs between 10 mm slice scan with standard algorithm and 2 mm thin-slice scan with bone algorithm, the latter was better on displaying the pulmonary axial interstium, intralobular septum, subpleura lines, honeycombing, 2-5 mm nodulars and anomalies of bronchial wall. Conclusion: According to the study of 135 cases, 2 mm thin-slice scan with bone algorithm is superior to 10 mm slice scan with standard algorithm in demonstrating the pulmonary lesions. It has a similar value with high-resolution spiral CT in the diagnosis of the pulmonary solitary or diffuse nodules, pulmonary diffuse interstitial lesions and the lesions of the airway. It is practical and advisable in the community hospital

  14. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    htmlabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  15. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    textabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  16. Colour behaviour on mango ( Mangifera indica ) slices self ...

    African Journals Online (AJOL)

    The effect of the syrup composition on behaviour colour of self stabilized mango slices in glass jars by hurdle technology during 180 days of storage was studied through 26-2 fractional factorial design. L* (lightness), a* (redness and greenness), and b* (yellowness and blueness) values were measured with a colorimeter ...

  17. Regulation of dopamine synthesis and release in striatal and prefrontal cortical brain slices

    International Nuclear Information System (INIS)

    Wolf, M.E.

    1986-01-01

    Brain slices were used to investigate the role of nerve terminal autoreceptors in modulating dopamine (DA) synthesis and release in striatum and prefrontal cortex. Accumulation of dihydroxyphenylalanine (DOPA) was used as an index of tyrosine hydroxylation in vitro. Nomifensine, a DA uptake blocker, inhibited DOPA synthesis in striatal but not prefrontal slices. This effect was reversed by the DA antagonist sulpiride, suggesting it involved activation of DA receptors by elevated synaptic levels of DA. The autoreceptor-selective agonist EMD-23-448 also inhibited striatal but not prefrontal DOPA synthesis. DOPA synthesis was stimulated in both brain regions by elevated K + , however only striatal synthesis could be further enhanced by sulpiride. DA release was measured by following the efflux of radioactivity from brain slices prelabeled with [ 3 H]-DA. EMD-23-448 and apomorphine inhibited, while sulpiride enhanced, the K + -evoked overflow of radioactivity from both striatal and prefrontal cortical slices. These findings suggest that striatal DA nerve terminals possess autoreceptors which modulate tyrosine hydroxylation as well as autoreceptors which modulate release. Alternatively, one site may be coupled to both functions through distinct transduction mechanisms. In contrast, autoreceptors on prefrontal cortical terminals appear to regulate DA release but not DA synthesis

  18. The Slice Algorithm For Irreducible Decomposition of Monomial Ideals

    DEFF Research Database (Denmark)

    Roune, Bjarke Hammersholt

    2009-01-01

    Irreducible decomposition of monomial ideals has an increasing number of applications from biology to pure math. This paper presents the Slice Algorithm for computing irreducible decompositions, Alexander duals and socles of monomial ideals. The paper includes experiments showing good performance...

  19. A procedure for culturing rat neocortex explants in a serum-free nutrient medium

    NARCIS (Netherlands)

    Romijn, H. J.; de Jong, B. M.; Ruijter, J. M.

    1988-01-01

    A procedure is described for long-term culturing of rat neocortex explants in a serum-free growth medium. Slices spanning the entire cortical depth from pial to ventricular side are prepared from 6-day-old rat pups. After preincubation in Hanks' balanced salt solution with extra glucose, the

  20. Comparison of MRI fast SPGR single slice scan and continuous dynamic scan in patients with obstructive sleep apnea-hypopnea syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xinyu [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: myginny2@sina.com; Yang Xue [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: yangxueqyfy@126.com; Hua Hui [Department of Otorhinolaryngology-Head and Neck Surgery, Medical School Hospital of Qingdao University, Qingdao (China)], E-mail: huahuisky@163.com; Chen Jingjing [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: chenjingjingsky@126.com

    2009-07-15

    Objective: To evaluate the application value of MRI fast SPGR single slice scan in patients with obstructive sleep apnea-hypopnea syndrome when comparing the images between fast SPGR single slice scan and continuous dynamic scan. Methods: Eighteen patients with obstructive sleep apnea-hypopnea syndrome were examined by fast SPGR single slice scan and continuous dynamic scan in turn. Fast SPGR single slice scans were conducted when the phases of apnea, inspiration and expiration appeared on the respiratory wave of the subjects. Fast SPGR continuous dynamic scans were conducted when the patients were awake and apneic. The scan planes were median sagittal plane and axial planes (the slice of middle part of palate, the slice of inferior part of palate, the slice of middle part of lingual root and the slice of 0.5 cm beneath the free margin of epiglottis). The obstructed sites and the cross-sectional areas of upper airway were compared between the two scan methods. Results: Seven cases showed complete obstruction at the narrowest sites of upper airway when apnea appeared; eleven cases showed marked decrease in cross-sectional areas at the narrowest sites compared with the areas when the patients were awake; two cases manifested multiple narrowness. The obstructed sites showed by the two scan methods were same. The difference of the cross-sectional areas of upper airway between the two scan methods was insignificant (P > 0.05). Conclusion: Fast SPGR single slice scan can accurately reflect the obstructed sites of upper airway when the breath breaks off and is the complementary method of continuous dynamic scan. Sometimes, single slice scan can replace continuous dynamic scan.

  1. Regulation of GABA and benzodiazepine receptors following neurotoxin-induced striatal and medial forebrain bundle lesions

    International Nuclear Information System (INIS)

    Pan, H.S.I.

    1985-01-01

    GABA, a major inhibitory transmitter, is used by many projection neurons of the striatum. To investigate the role of GABA in striatal function, the GABA receptor complex was studied after lesions of the striatum or the nigrostriatal neurons. Quantitative receptor autoradiography using thaw-mounted tissue slices was developed for the study of GABA and benzodiazepine (BDZ) receptors. With the technique established, binding to GABA and BDZ receptors after unilateral striatal kainate lesions was examined. Subsequently, changes in GABA and BDZ receptors were studied following the destruction of dopaminergic nigrostriatal cells by unilateral 6-hydroxydopamine lesion of the medial forebrain bundle. In summary, quantitative receptor autoradiography allowed the detection of GABA and BDZ receptor changes in multiple small areas in each lesioned brain. This technique made it feasible to carry out kinetic saturation, and competition studies using less than 1 mg of tissue. The data suggest that dopamine is functionally inhibitory on striatopallidal neurons but is functionally excitatory on striatoentopeduncular and striatonigral cells which in turn inhibit the thalamus. This quantitative autoradiographic technique can be generalized to study other transmitter receptors and can be combined with 2-deoxyglucose uptake studies

  2. A Unified Approach to Diffusion Direction Sensitive Slice Registration and 3-D DTI Reconstruction From Moving Fetal Brain Anatomy

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Seshamani, Sharmishtaa; Kroenke, Christopher

    2014-01-01

    to the underlying anatomy. Previous image registration techniques have been described to estimate the between slice fetal head motion, allowing the reconstruction of 3D a diffusion estimate on a regular grid using interpolation. We propose Approach to Unified Diffusion Sensitive Slice Alignment and Reconstruction...... (AUDiSSAR) that explicitly formulates a process for diffusion direction sensitive DW-slice-to-DTI-volume alignment. This also incorporates image resolution modeling to iteratively deconvolve the effects of the imaging point spread function using the multiple views provided by thick slices acquired...

  3. Recent developments in multi-wire fixed abrasive slicing technique (FAST). [for low cost silicon wafer production from ingots

    Science.gov (United States)

    Schmid, F.; Khattak, C. P.; Smith, M. B.; Lynch, L. D.

    1982-01-01

    Slicing is an important processing step for all technologies based on the use of ingots. A comparison of the economics of three slicing techniques shows that the fixed abrasive slicing technique (FAST) is superior to the internal diameter (ID) and the multiblade slurry (MBS) techniques. Factors affecting contact length are discussed, taking into account kerf width, rocking angle, ingot size, and surface speed. Aspects of blade development are also considered. A high concentration of diamonds on wire has been obtained in wire packs usd for FAST slicing. The material removal rate was found to be directly proportional to the pressure at the diamond tips.

  4. X-radiography of slices of the Allende Meteorite

    Science.gov (United States)

    Smith, M. J.; Anderson, J. B.; Heymann, D.

    1984-01-01

    A 2.2 kg fragment of the Allende Meteorite was derinded and sliced by bandsawing. Several X-radiographs were made of all slices. The following features are resolved: grains of blocky troilite (bright spots), troilite rimmed chondrules (bright halos), chondrules with central vugs (dim halos), white aggregates (dark patches), and dark inclusions (medium dark patches). The number of FeS grains larger than about 0.5 mm is one per 6 + or - 1 gram of this fragment. Their concentration appears to be uniform at the 1 kg weight level, but is not uniform at the 100 g level. The number of FeS rimmed chondrules is one per 10 g. Their concentration is also nonuniform at the 100 g weight level. The number of white aggregates is roughly one per 20 g. These disc shaped objects show a distinct preferred orientation of the axis orthogonal to the plane of the disc. Chondrules with central vugs are numerous. Linear and curved arrays of chondrules, up to a few cm long, were observed. An interpretation of the observed features is given.

  5. Gender differences in nigrostriatal dopaminergic innervation are present at young-to-middle but not at older age in normal adults.

    Science.gov (United States)

    Wong, Ka Kit; Müller, Martijn L T M; Kuwabara, Hiroto; Studenski, Stephanie A; Bohnen, Nicolaas I

    2012-01-01

    Gender differences in brain dopaminergic activity have been variably reported in the literature. We performed an evaluation for gender effects on striatal dopamine transporter (DAT) binding in a group of normal subjects. Community-dwelling adults (n = 85, 50F/35M, mean age 62.7 ± 16.2 SD, range 20-85) underwent DAT [(11)C]2-β-carbomethoxy-3β-(4-fluorophenyl) tropane (β-CFT) positron emission tomography (PET) imaging. Gender effects for DAT binding were compared using ANCOVA for two subgroups; young-to-middle aged adults and older adults, using an age threshold of 60 years. There were 54 subjects (24M/30F; mean age 72.9 ± 7.3) 60 years and older and 31 (11M/20F; mean age 45.0 ± 11.4) subjects younger than 60. Age-adjusted striatal DAT gender effects were present in the young-to-middle (F = 10.4, P = 0.003) but not in the elderly age group (F = 0.5, ns). Gender differences in nigrostriatal dopaminergic innervation are present, with higher levels of DAT binding in young-to-middle age women compared to men, but not present in the elderly. Published by Elsevier Ltd.

  6. A sandwich-like differential B-dot based on EACVD polycrystalline diamond slice

    Science.gov (United States)

    Xu, P.; Yu, Y.; Xu, L.; Zhou, H. Y.; Qiu, C. J.

    2018-06-01

    In this article, we present a method of mass production of a standardized high-performance differential B-dot magnetic probe together with the magnetic field measurement in a pulsed current device with the current up to hundreds of kilo-Amperes. A polycrystalline diamond slice produced in an Electron Assisted Chemical Vapor Deposition device is used as the base and insulating material to imprint two symmetric differential loops for the magnetic field measurement. The SP3 carbon bond in the cubic lattice structure of diamond is confirmed by Raman spectra. The thickness of this slice is 20 μm. A gold loop is imprinted onto each surface of the slice by using the photolithography technique. The inner diameter, width, and thickness of each loop are 0.8 mm, 50 μm, and 1 μm, respectively. It provides a way of measuring the pulsed magnetic field with a high spatial and temporal resolution, especially in limited space. This differential magnetic probe has demonstrated a very good common-mode rejection rate through the pulsed magnetic field measurement.

  7. Application of gamma irradiation for the microbiological safety of sliced cheddar cheese

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Song, Beom Seok; Kim, Jae Hun; Choi, Jong Ill; Lee, Ju Woon; Byun, Myung Woo [Radiation Research Center for Innovative Technology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Jo, Cheo Run [Dept. of Animal Science and Biotechnology, Chungnam National University, Daejeon (Korea, Republic of)

    2007-05-15

    This study was conducted to establish the microbiological safety of sliced cheddar cheese with gamma irradiation. Total aerobic bacteria was 2.50 Log CFUg-1 in non-irradiated sample. No viable cells were observed in the gamma-irradiated at 1 kGy and over. D10 value for Listeria monocytogenes and Staphylococcus aureus inoculated in sliced cheddar cheese were 0.64 and 0.54 kGy, respectively. TBARS (2-thiobarbituric acid reactive substances) values were increased as irradiation dose was increased, but there was no significant difference between nonirradiated and irradiated samples at 1 kGy. Sensory evaluation showed there was no significant difference between samples irradiated at 1 kGy and non-irradiated in respect of color, odor, overall acceptability. Theses results indicated that gamma irradiation at 1 kGy was considered to be an effective treatment to ensure the microbiological safety of sliced cheddar cheese with minimal change of sensory, even though further studies should be investigated to reduce the deterioration of sensory quality induced by gamma irradiation.

  8. A slice through a prototype LHC bending magnet

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This slice through a prototype LHC magnet clearly shows the superconducting cable in several blocks around the central hole – the beam pipe in which the LHC’s accelerated beams will travel. Magnet design is crucial to the LHC’s success and this sample is among the first to be built to the final cable configuration.

  9. Altered Loyalties of Neuronal Markers in Cultured Slices of Resected Human Brain Tissue

    NARCIS (Netherlands)

    Verwer, Ronald W. H.; Sluiter, Arja A.; Balesar, Rawien A.; Baayen, Johannes C.; Speijer, Dave; Idema, Sander; Swaab, Dick F.

    2016-01-01

    Organotypic cultures from normal neocortical tissue obtained at epilepsy surgery show a severe injury response. This response involves both neuronal degeneration and the proliferation of reactive cells. A salient feature of the reactive cells is the co-expression of microglial and astrocytic

  10. Modulation of methylmercury uptake by methionine: Prevention of mitochondrial dysfunction in rat liver slices by a mimicry mechanism

    International Nuclear Information System (INIS)

    Roos, Daniel Henrique; Puntel, Robson Luiz; Farina, Marcelo; Aschner, Michael; Bohrer, Denise; Rocha, Joao Batista T.; Vargas Barbosa, Nilda B. de

    2011-01-01

    Methylmercury (MeHg) is an ubiquitous environmental pollutant which is transported into the mammalian cells when present as the methylmercury-cysteine conjugate (MeHg-Cys). With special emphasis on hepatic cells, due to their particular propensity to accumulate an appreciable amount of Hg after exposure to MeHg, this study was performed to evaluate the effects of methionine (Met) on Hg uptake, reactive species (RS) formation, oxygen consumption and mitochondrial function/cellular viability in both liver slices and mitochondria isolated from these slices, after exposure to MeHg or the MeHg-Cys complex. The liver slices were pre-treated with Met (250 μM) 15 min before being exposed to MeHg (25 μM) or MeHg-Cys (25 μM each) for 30 min at 37 o C. The treatment with MeHg caused a significant increase in the Hg concentration in both liver slices and mitochondria isolated from liver slices. Moreover, the Hg uptake was higher in the group exposed to the MeHg-Cys complex. In the DCF (dichlorofluorescein) assay, the exposure to MeHg and MeHg-Cys produced a significant increase in DFC reactive species (DFC-RS) formation only in the mitochondria isolated from liver slices. As observed with Hg uptake, DFC-RS levels were significantly higher in the mitochondria treated with the MeHg-Cys complex compared to MeHg alone. MeHg exposure also caused a marked decrease in the oxygen consumption of liver slices when compared to the control group, and this effect was more pronounced in the liver slices treated with the MeHg-Cys complex. Similarly, the loss of mitochondrial activity/cell viability was greater in liver slices exposed to the MeHg-Cys complex when compared to slices treated only with MeHg. In all studied parameters, Met pre-treatment was effective in preventing the MeHg- and/or MeHg-Cys-induced toxicity in both liver slices and mitochondria. Part of the protection afforded by Met against MeHg may be related to a direct interaction with MeHg or to the competition of Met with

  11. Single-slice epicardial fat area measurement. Do we need to measure the total epicardial fat volume?

    International Nuclear Information System (INIS)

    Oyama, Noriko; Goto, Daisuke; Ito, Yoichi M.

    2011-01-01

    The aim of this study was to assess a method for measuring epicardial fat volume (EFV) by means of a single-slice area measurement. We investigated the relation between a single-slice fat area measurement and total EFV. A series of 72 consecutive patients (ages 65±11 years; 36 men) who had undergone cardiac computed tomography (CT) on a 64-slice multidetector scanner with prospective electrocardiographic triggering were retrospectively reviewed. Pixels in the pericardium with a density range from -230 to -30 Hounsfield units were considered fat, giving the per-slice epicardial fat area (EFA). The EFV was estimated by the summation of EFAs multiplied by the slice thickness. We investigated the relation between total EFV and each EFA. EFAs measured at several anatomical landmarks - right pulmonary artery, origins of the left main coronary artery, right coronary artery, coronary sinus - all correlated with the EFV (r=0.77-0.92). The EFA at the LMCA level was highly reproducible and showed an excellent correlation with the EFV (r=0.92). The EFA is significantly correlated with the EFV. The EFA is a simple, quick method for representing the time-consuming EFV, which has been used as a predictive indicator of cardiovascular diseases. (author)

  12. Neural stem cells improve neuronal survival in cultured postmortem brain tissue from aged and Alzheimer patients

    NARCIS (Netherlands)

    Wu, L.; Sluiter, A.A.; Guo, Ho Fu; Balesar, R. A.; Swaab, D. F.; Zhou, Jiang Ning; Verwer, R. W H

    Neurodegenerative diseases are progressive and incurable and are becoming ever more prevalent. To study whether neural stem cell can reactivate or rescue functions of impaired neurons in the human aging and neurodegenerating brain, we co-cultured postmortem slices from Alzheimer patients and control

  13. Constructing a Computer Model of the Human Eye Based on Tissue Slice Images

    OpenAIRE

    Dai, Peishan; Wang, Boliang; Bao, Chunbo; Ju, Ying

    2010-01-01

    Computer simulation of the biomechanical and biological heat transfer in ophthalmology greatly relies on having a reliable computer model of the human eye. This paper proposes a novel method on the construction of a geometric model of the human eye based on tissue slice images. Slice images were obtained from an in vitro Chinese human eye through an embryo specimen processing methods. A level set algorithm was used to extract contour points of eye tissues while a principle component analysi...

  14. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    Energy Technology Data Exchange (ETDEWEB)

    Khalvati, Farzad, E-mail: farzad.khalvati@uwaterloo.ca; Tizhoosh, Hamid R. [Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); Salmanpour, Aryan; Rahnamayan, Shahryar [Department of Engineering and Applied Science, University of Ontario Institute of Technology, Oshawa, Ontario L1H 7K4 (Canada); Rodrigues, George [Department of Radiation Oncology, London Regional Cancer Program, London, Ontario N6C 2R6, Canada and Department of Epidemiology/Biostatistics, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2013-12-15

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

  15. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    International Nuclear Information System (INIS)

    Khalvati, Farzad; Tizhoosh, Hamid R.; Salmanpour, Aryan; Rahnamayan, Shahryar; Rodrigues, George

    2013-01-01

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability

  16. The Sliced Pineapple Grid Feature for Predicting Grasping Affordances

    DEFF Research Database (Denmark)

    Thomsen, Mikkel Tang; Kraft, Dirk; Krüger, Norbert

    2017-01-01

    The problem of grasping unknown objects utilising vision is addressed in this work by introducing a novel feature, the Sliced Pineapple Grid Feature (SPGF). The SPGF encode semi-local surfaces and allows for distinguishing structures such as “walls”,“edges” and “rims”. These structures are shown...

  17. Electrical coupling between hippocampal astrocytes in rat brain slices.

    Science.gov (United States)

    Meme, William; Vandecasteele, Marie; Giaume, Christian; Venance, Laurent

    2009-04-01

    Gap junctions in astrocytes play a crucial role in intercellular communication by supporting both biochemical and electrical coupling between adjacent cells. Despite the critical role of electrical coupling in the network organization of these glial cells, the electrophysiological properties of gap junctions have been characterized in cultures while no direct evidence has been sought in situ. In the present study, gap-junctional currents were investigated using simultaneous dual whole-cell patch-clamp recordings between astrocytes from rat hippocampal slices. Bidirectional electrotonic coupling was observed in 82% of the cell pairs with an average coupling coefficient of 5.1%. Double patch-clamp analysis indicated that junctional currents were independent of the transjunctional voltage over a range from -100 to +110 mV. Interestingly, astrocytic electrical coupling displayed weak low-pass filtering properties compared to neuronal electrical synapses. Finally, during uncoupling processes triggered by either the gap-junction inhibitor carbenoxolone or endothelin-1, an increase in the input resistance in the injected cell paralleled the decrease in the coupling coefficient. Altogether, these results demonstrate that hippocampal astrocytes are electrically coupled through gap-junction channels characterized by properties that are distinct from those of electrical synapses between neurons. In addition, gap-junctional communication is efficiently regulated by endogenous compounds. This is taken to represent a mode of communication that may have important implications for the functional role of astrocyte networks in situ.

  18. Effect of dentin bonding agent diffusing through dentin slices on the reactive oxygen species production and apoptosis of pulpal cells

    Directory of Open Access Journals (Sweden)

    Bor-Shiunn Lee

    2015-04-01

    Conclusion: The three DBAs after diffusion through 0.2- or 0.5-mm dentin slice still exhibit cytotoxicity to dental pulp cells. However, the 0.5-mm dentin slice is found to be a better barrier than the 0.2-mm dentin slice to protect dental pulp cells from DBA-induced cytotoxicity.

  19. Unbiased stereological estimation of d-dimensional volume in Rn from an isotropic random slice through a fixed point

    DEFF Research Database (Denmark)

    Jensen, Eva B. Vedel; Kiêu, K

    1994-01-01

    Unbiased stereological estimators of d-dimensional volume in R(n) are derived, based on information from an isotropic random r-slice through a specified point. The content of the slice can be subsampled by means of a spatial grid. The estimators depend only on spatial distances. As a fundamental ...... lemma, an explicit formula for the probability that an isotropic random r-slice in R(n) through 0 hits a fixed point in R(n) is given....

  20. The effect of slicing type on drying kinetics and quality of dried carrot

    Directory of Open Access Journals (Sweden)

    M Naghipour zadeh mahani

    2016-04-01

    Full Text Available Introduction: Carrot is one of the most common vegetables used for human nutrition because of its high vitamin and fiber contents. Drying improves the product shelf life without addition of any chemical preservative and reduces both the size of package and the transport cost. Drying also aidsto reduce postharvest losses of fruits and vegetables especially, which can be as high as 70%. Dried carrots are used in dehydrated soups and in the form of powder in pastries and sauces. The main aim of drying agricultural products is decrease the moisture content to a level which allows safe storage over an extended period. Many fruits and vegetables can be sliced before drying.because of different tissue of a fruit or vegetable, cutting them in different direction and shape created different tissue slices. Due to drying is the exiting process of the moisture from internal tissue so different tissue slices caused different drying kinetics. Therefore, the study on effect of cutting parameters on drying is necessary. Materials and Methods: Carrots (Daucus carota L. were purchased from the local market (Kerman, Iran and stored in a refrigerator at 5°C. The initial moisture contents of the Carrot samples were determined by the oven drying method. The sample was dried in an oven at 105±2°C about 24 hours. The carrots cut by 3 models blade at 3 directions. The samples were dried in an oven at 70°C. Moisture content of the carrot slices were determined by weighting of samples during drying. Volume changes because of sample shrinkage were measured by a water displacement method. Rehydration experiment was performed by immersing a weighted amount of dried samples into hot water 50 °C for 30 min. In this study the effect of some cutting parameters was considered on carrot drying and the quality of final drying product. The tests were performed as a completely random design. The effects of carrot thickness at two levels (3 and 6 mm, blade in 3 models (flat blade

  1. Liver slices in in vitro pharmacotoxicology with special reference to the use of human liver tissue

    NARCIS (Netherlands)

    Olinga, Peter; Meijer, D.K F; Slooff, M.JH; Groothuis, Geny

    In the early years of research in in vitro pharmacotoxicology liver slices have been used. After a decline in the application of slices in favour of the use of isolated hepatocytes and the isolated perfused liver preparation, the development of the Krumdieck slicer in the 1980s led to a 'comeback'

  2. Long-term potentiation protects rat hippocampal slices from the effects of acute hypoxia.

    Science.gov (United States)

    Youssef, F F; Addae, J I; McRae, A; Stone, T W

    2001-07-13

    We have previously shown that long-term potentiation (LTP) decreases the sensitivity of glutamate receptors in the rat hippocampal CA1 region to exogenously applied glutamate agonists. Since the pathophysiology of hypoxia/ischemia involves increased concentration of endogenous glutamate, we tested the hypothesis that LTP could reduce the effects of hypoxia in the hippocampal slice. The effects of LTP on hypoxia were measured by the changes in population spike potentials (PS) or field excitatory post-synaptic potentials (fepsps). Hypoxia was induced by perfusing the slice with (i) artificial CSF which had been pre-gassed with 95%N2/5% CO2; (ii) artificial CSF which had not been pre-gassed with 95% O2/5% CO2; or (iii) an oxygen-glucose deprived (OGD) medium which was similar to (ii) and in which the glucose had been replaced with sucrose. Exposure of a slice to a hypoxic medium for 1.5-3.0 min led to a decrease in the PS or fepsps; the potentials recovered to control levels within 3-5 min. Repeat exposure, 45 min later, of the same slice to the same hypoxic medium for the same duration as the first exposure caused a reduction in the potentials again; there were no significant differences between the degree of reduction caused by the first or second exposure for all three types of hypoxic media (P>0.05; paired t-test). In some of the slices, two episodes of LTP were induced 25 and 35 min after the first hypoxic exposure; this caused inhibition of reduction in potentials caused by the second hypoxic insult which was given at 45 min after the first; the differences in reduction in potentials were highly significant for all the hypoxic media used (Peffects of LTP were not prevented by cyclothiazide or inhibitors of NO synthetase compounds that have been shown to be effective in blocking the effects of LTP on the actions of exogenously applied AMPA and NMDA, respectively. The neuroprotective effects of LTP were similar to those of propentofylline, a known neuroprotective

  3. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  4. The slice balance approach (SBA): a characteristic-based, multiple balance SN approach on unstructured polyhedral meshes

    International Nuclear Information System (INIS)

    Grove, R.E.

    2005-01-01

    The Slice Balance Approach (SBA) is an approach for solving geometrically-complex, neutral-particle transport problems within a multi-group discrete ordinates (S N ) framework. The salient feature is an angle-dependent spatial decomposition. We approximate general surfaces with arbitrary polygonal faces and mesh the geometry with arbitrarily-shaped polyhedral cells. A cell-local spatial decomposition divides cells into angle-dependent slices for each S N direction. This subdivision follows from a characteristic-based view of the transport problem. Most balance-based characteristic methods use it implicitly; we use it explicitly and exploit its properties. Our mathematical approach is a multiple balance approach using exact spatial moments balance equations on cells and slices along with auxiliary relations on slices. We call this the slice balance approach; it is a characteristic-based multiple balance approach. The SBA is intentionally general and can extend differencing schemes to arbitrary 2-D and 3-D meshes. This work contributes to development of general-geometry deterministic transport capability to complement Monte Carlo capability for large, geometrically-complex transport problems. The purpose of this paper is to describe the SBA. We describe the spatial decomposition and mathematical framework and highlight a few interesting properties. We sketch the derivation of two solution schemes, a step characteristic scheme and a diamond-difference-like scheme, to illustrate the approach and we present interesting results for a 2-D problem. (author)

  5. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  6. Comparison of sliced lungs with whole lung sets for a torso phantom measured with Ge detectors using Monte Carlo simulations (MCNP).

    Science.gov (United States)

    Kramer, Gary H; Guerriere, Steven

    2003-02-01

    Lung counters are generally used to measure low energy photons (<100 keV). They are usually calibrated with lung sets that are manufactured from a lung tissue substitute material that contains homogeneously distributed activity; however, it is difficult to verify either the activity in the phantom or the homogeneity of the activity distribution without destructive testing. Lung sets can have activities that are as much as 25% different from the expected value. An alternative method to using whole lungs to calibrate a lung counter is to use a sliced lung with planar inserts. Experimental work has already indicated that this alternative method of calibration can be a satisfactory substitute. This work has extended the experimental study by the use of Monte Carlo simulation to validate that sliced and whole lungs are equivalent. It also has determined the optimum slice thicknesses that separate the planar sources in the sliced lung. Slice thicknesses have been investigated in the range of 0.5 cm to 9.0 cm and at photon energies from 17 keV to 1,000 keV. Results have shown that there is little difference between sliced and whole lungs at low energies providing that the slice thickness is 2.0 cm or less. As the photon energy rises the slice thickness can increase substantially with no degradation on equivalence.

  7. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    International Nuclear Information System (INIS)

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-01

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies

  8. Radioisotopic investigations of zinc uptake into brain slices

    International Nuclear Information System (INIS)

    Howell, G.A.

    1983-01-01

    The presence of zinc in the vicinity of the hippocampal mossy fibers has been repeatedly demonstrated, and several lines of evidence suggest that the mossy-fiber zinc is concentrated within the terminals of mossy fibers. In search of insight into the metabolism and function of mossy-fiber zinc, the present study investigated the transport of zinc into tissue slices and the response of the zinc transport to depolarization. Kinetic analysis of zinc accumulation by mouse brain slices in vitro revealed the presence of a high affinity uptake component with an apparent Km of 17.7 μM for hippocampus, 16.6 μM< for cortex and 25 μM for striatum and a V/sub max/ of 9.2 ng/mg/hr for the hippocampus, 10.1 ng/mg/hr for cortex and 9.6 ng/mg/hr for striatum. Cytoarchitectonic differences in zinc transport between the different hippocampal subregions were found with those regions containing granule cells or mossy fiber axons accumulating greater amounts of zinc than the CA 1 region. The present finding that mossy-fiber neuropil selectivity accumulates zinc suggests the presence of a zinc-binding substance unique to mossy-fiber tissue

  9. Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yu-Min; Sun, Ai-Min; Wang, Qian; Zhu, Ming; Qiu, Hai-Sheng [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Radiology, Shanghai (China); Jaffe, Richard B. [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States); Liu, Jin-Fen [Shanghai Children' s Medical Center, Department of Cardiothoracic Surgery, Shanghai (China); Gao, Wei [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Cardiology, Shanghai (China); Berdon, Walter E. [Children' s Hospital of New York, Department of Radiology, New York, NY (United States)

    2014-07-15

    Absent pulmonary valve is a rare cardiovascular anomaly that can result in profound tracheobronchial compression. To demonstrate the advantage of multi-slice CT in diagnosing tracheobronchial compression, its severity as related to the adjacent dilated pulmonary arteries, and associated lung and cardiac lesions. We included children with absent pulmonary valve who were reviewed by multi-slice CT during a 17-year period. The number and locations of stenoses and lung lesions were noted and the severity of stenosis was categorized. The diameter of the pulmonary artery was measured and associated cardiac defects were demonstrated. Thirty-one children (14 girls and 17 boys) were included. Of these, 29 had ventricular septal defect and 2 had an intact ventricular septum. Twenty-nine children (94%) had tracheobronchial compression, judged to be mild in nine children (31%), moderate in 10 (34%) and severe in 10 (34%). The different locations of the stenosis (carina, main bronchi, lobar and segmental bronchi) were observed. And the number and location of lung lesions demonstrated that the right middle and left upper and lower lobes were often affected. The diameter of the pulmonary artery in these children was well above normal published values, and Spearman rank correlation analysis showed a correlation between the size of the pulmonary artery and the severity of the tracheobronchial stenosis. Nineteen children (61%) underwent surgery and 4 of these children had a multi-slice CT post-operative follow-up study. Absent pulmonary valve can cause significant morbidity and mortality in children. Multi-slice CT can accurately depict areas of tracheobronchial compression, associated lung lesions and cardiac defects, helping to direct the surgeon. (orig.)

  10. Using a high-speed movie camera to evaluate slice dropping in clinical image interpretation with stack mode viewers.

    OpenAIRE

    Yakami, Masahiro; Yamamoto, Akira; Yanagisawa, Morio; Sekiguchi, Hiroyuki; Kubo, Takeshi; Togashi, Kaori

    2013-01-01

    The purpose of this study is to verify objectively the rate of slice omission during paging on picture archiving and communication system (PACS) viewers by recording the images shown on the computer displays of these viewers with a high-speed movie camera. This study was approved by the institutional review board. A sequential number from 1 to 250 was superimposed on each slice of a series of clinical Digital Imaging and Communication in Medicine (DICOM) data. The slices were displayed using ...

  11. Multi-slice and dual-source CT in cardiac imaging. Principles - protocols - indications - outlook. 2. ed.

    International Nuclear Information System (INIS)

    Ohnesorge, B.M.; Flohr, T.G.; Becker, C.R.; Reiser, M.F.; Knez, A

    2007-01-01

    Cardiac diseases, and in particular coronary artery disease, are the leading cause of death and morbidity in industrialized countries. The development of non-invasive imaging techniques for the heart and the coronary arteries has been considered a key element in improving patient care. A breakthrough in cardiac imaging using CT occurred in 1998, with the introduction of multi-slice computed tomography (CT). Since then, amazing advances in performance have taken place with scanners that acquire up to 64 slices per rotation. This book discusses the state-of-the-art developments in multi-slice CT for cardiac imaging as well as those that can be anticipated in the future. It serves as a comprehensive work that covers all aspects of this technology, from the technical fundamentals and image evaluation all the way to clinical indications and protocol recommendations. This fully reworked second edition draws on the most recent clinical experience obtained with 16- and 64-slice CT scanners by world-leading experts from Europe and the United States. It also includes ''hands-on'' experience in the form of 10 representative clinical case studies, which are included on the accompanying CD. As a further highlight, the latest results of the very recently introduced dual-source CT, which may soon represent the CT technology of choice for cardiac applications, are presented. This book will not only convince the reader that multi-slice cardiac CT has arrived in clinical practice, it will also make a significant contribution to the education of radiologists, cardiologists, technologists, and physicists-whether newcomers, experienced users, or researchers. (orig.)

  12. PICTURE, 2-D Slices Through 3-D CG of MORSE, QAD-CG

    International Nuclear Information System (INIS)

    1994-01-01

    1 - Description of program or function: Picture generates plots of two-dimensional slices through the three-dimensional geometry described by the combinatorial geometry (CG) package used in such codes as MORSE and QAD-CG. These plots are printed on a standard line printer. 2 - Method of solution: Several different ways are available to obtain a two-dimensional slice through the geometry. The geometry ray tracing capability is tested by forcing the geometry package to execute the routines and logic of the Monte Carlo random walk or kernel integration algorithms. 3 - Restrictions on the complexity of the problem: None tested besides those listed in the input descriptions

  13. Effect of Slice Error of Glass on Zero Offset of Capacitive Accelerometer

    Science.gov (United States)

    Hao, R.; Yu, H. J.; Zhou, W.; Peng, B.; Guo, J.

    2018-03-01

    Packaging process had been studied on capacitance accelerometer. The silicon-glass bonding process had been adopted on sensor chip and glass, and sensor chip and glass was adhered on ceramic substrate, the three-layer structure was curved due to the thermal mismatch, the slice error of glass lead to asymmetrical curve of sensor chip. Thus, the sensitive mass of accelerometer deviated along the sensitive direction, which was caused in zero offset drift. It was meaningful to confirm the influence of slice error of glass, the simulation results showed that the zero output drift was 12.3×10-3 m/s2 when the deviation was 40μm.

  14. Effect of calcium chloride and calcium lactate on quality and shelf-life of fresh-cut guava slices

    International Nuclear Information System (INIS)

    Raheem, M.I.U.; Huma, N.; Anjum, F.M.

    2013-01-01

    Present study was conducted to investigate the effectiveness of chemical treatments at low temperature on the quality of fresh-cut guava slices during 2011-12. Uniform sized guava slices were made free from seeds and treated with calcium chloride and calcium lactate with concentration 0.9%, 1.8%, 2.7% or 3.6%. After packing in plastic boxes, all treated samples were stored at 5 degree C + 2 degree C in a refrigerator for 24 days with 6 day interval between different removals. The results obtained from physico-chemical analysis showed decrease in firmness (111.67-12.67gf) and increase in browning (1.19-1.93nm) of guava slices compared to control with the passage of storage interval. Moreover, scores in taste (7.33-1.00), flavour (7.33-1.00), colour (7.50-1.00) and texture (7.67-1.00) of guava slices was also decreased with respect to interaction of treatments and storage period. Calcium chloride at the rate 2.7% showed significantly higher stability than other concentrations of calcium chloride and calcium lactate in delaying firmness and browning of fresh-cut guava slices along with maintaining their organoleptic properties for longer storage period. However, calcium chloride imparted undesirable bitterness to fresh-cut guava slices at the concentration of 3.6%. Based on the overall quality performance, 2.7% calcium chloride and 3.6% calcium lactate exhibited better results than other concentrations and control with storage life of 8 days at 5 degree C + 2 degree C. (author)

  15. Characterization of masses in digital breast tomosynthesis: comparison of machine learning in projection views and reconstructed slices.

    Science.gov (United States)

    Chan, Heang-Ping; Wu, Yi-Ta; Sahiner, Berkman; Wei, Jun; Helvie, Mark A; Zhang, Yiheng; Moore, Richard H; Kopans, Daniel B; Hadjiiski, Lubomir; Way, Ted

    2010-07-01

    In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 degree arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered

  16. A COMPARATIVE STUDY OF TYMPANOPLASTY USING SLICED CARTILAGE GRAFT VS. TEMPORALIS FASCIA GRAFT

    Directory of Open Access Journals (Sweden)

    Rahul Ashok Telang

    2018-02-01

    Full Text Available BACKGROUND The objective of the study was to compare the hearing improvement after using sliced cartilage graft with that of temporalis fascia and to compare the graft take-up between the two graft materials. MATERIALS AND METHODS A prospective clinical study including 60 patients with chronic mucosal otitis media, who were selected randomly from the outpatient department, after obtaining their consent were divided into 2 groups of 30 each, and evaluated according the study protocol. Their pre-operative audiometry was recorded and both groups of patients underwent surgery with one of the graft materials- temporalis fascia or sliced tragal cartilage with a thickness of 0.5 mm. All patients were regularly followed up and post-operative audiometry was done at 3 months. The hearing improvement in the form of closure of air-bone-gap and graft take-up was analysed statistically. RESULTS The temporalis fascia graft group had a pre-operative ABG of 22.33 ± 6.24 dB and post-operative ABG of 12.33 ± 4.72 dB with hearing improvement of 10.00 dB. The sliced cartilage graft group had a pre-operative ABG of 20.77 ± 5.75 dB and postoperative ABG of 10.50 ± 4.46 dB with hearing improvement of 10.27 dB. In the temporalis fascia group, 28 (93.3% patients had good graft take-up and in the sliced cartilage group 29 (96.7% had good graft take-up. There was statistically significant hearing improvement in both of our study groups but there was no statistically significant difference between the two groups. There was no statistically significant difference in graft take-up also. CONCLUSION Sliced cartilage graft is a good auto-graft material in tympanoplasty, which can give good hearing improvement and has good graft take-up, which is comparable with that of temporalis fascia.

  17. Effects of Administration of Perinatal Bupropion on the Population Spike Amplitude in Neonatal Rat Hippocampal Slice

    Directory of Open Access Journals (Sweden)

    Soomaayeh Heysieat-talab

    2010-09-01

    Full Text Available Objective(sBupropion is an atypical antidepressant that is widely used in smoke cessation under FDA approval. The study of synaptic effects of bupropion can help to finding out its mechanism(s for stopping nicotine dependence. In this study the effects of perinatal bupropion on the population spike (PS amplitude of neonates were investigated. Materials and Methods Hippocampal slices were prepared from 18-25 days old rat pups. The experimental groups included control and bupropion-treated. Bupropion (40 mg/Kg, i.p. was applied daily in perinatal period as pre-treatment. Due to the studying acute effects, bupropion was also added to the perfusion medium (10, 50, 200 μM for 30 min. The evoked PS was recorded from pyramidal layer of CA1 area, following stimulation of Schaffer collaterals. ResultsA concentration of 10 μM bupropion had no significant effects on the PS amplitude. The 50 μM concentration of bupropion reduced the amplitude of responses in 50% of the studied cases. At a concentration of 200 μM, the recorded PS amplitudes were reduced in all slices (n= 22. Amplitude was completely abolished in 8 out of the 22 slices. The decrease of the PS amplitude was found to be more in the non-pre-treated slices than in the pre-treated slices when both were perfused with 200 μM bupropion.Conclusion The results showed the perinatal exposure to bupropion and its acute effects while indicating that at concentrations of 50 and 200 μM bupropion reduced the PS amplitude. It was also found that there was evidence of synaptic adaptation in comparison of bupropion-treated and non-treated slices whereas they were both perfused with 200 µM.

  18. Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses.

    NARCIS (Netherlands)

    Scheenen, T.W.J.; Heerschap, A.; Klomp, D.W.J.

    2008-01-01

    OBJECTIVE: To explore the possibilities of proton spectroscopic imaging (1H-MRSI) of the human brain at 7 Tesla with adiabatic refocusing pulses. MATERIALS AND METHODS: A combination of conventional slice selective excitation and two pairs of slice selective adiabatic refocusing pulses (semi-LASER)

  19. Gravitational clustering of galaxies in the CfA slice

    International Nuclear Information System (INIS)

    Crane, P.; Saslaw, W.C.

    1988-01-01

    The clustering properties of the Galaxies in the CfA slice have been analyzed by comparing the properties of the neighbor distributions to the predictions of gravitational clustering theory. The agreement is excellent and implies that the observed structures can be explained by gravitational effects alone and do not require exotic explanations

  20. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    International Nuclear Information System (INIS)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M.; Welte, T.; Kropf, S.

    2000-01-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  1. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    Energy Technology Data Exchange (ETDEWEB)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M. [Department of Diagnostic Radiology, Otto-von-Guericke University, Magdeburg (Germany); Welte, T. [Department of Cardiology, Angiology, and Pneumology, Otto-von-Guericke University, Magdeburg (Germany); Kropf, S. [Department of Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg (Germany)

    2000-06-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  2. A Comparative Study of Spiral Tomograms with Different Slice Thicknesses in Dental Implant Planning

    International Nuclear Information System (INIS)

    Yoon Sook Ja

    1999-01-01

    To know whether there would be a difference among spiral tomograms of different slice thicknesses in the measurement of distances which are used for dental implant planning. 10 dry mandibules and 40 metal balls are used to take total 120 Scanora tomograms with the slice thickness of 2 mm, 4 mm and 8 mm. 3 oral radiologists interpreted each tomogram to measure the distances from the mandibular canal to the alveoalr crest and buccal, lingual and inferior borders of mandible. 3 observers recorded grades of 0, 1 or 2 to evaluate the perceptibility of alveolar crest and the superior border of mandibular canal. For statistical analysis, ANOVA with repeated measure, Chi-square tests and intraclass correlation coefficient (R2, alpha) were used. There was not a statistically significant difference among spiral tomograms with different slice thicknesses in the measurement of the distances and in the perceptibility of alveolar crest and mandibular canal (p>0.05). All of them showed a good relationship in the reliability analysis. The perceptibility of alveolar crest and mandibular canal was almost similar and an excellent relationship was seen on all of them. There would be no significant difference, no matter which spiral tomogram of any slice thickness may be used in dental implant planning, considering the thickness of dental implant fixture.

  3. Growth potential of Listeria monocytogenes in sliced turkey bresaola packed in modified atmosphere

    Directory of Open Access Journals (Sweden)

    Elena Dalzini

    2014-02-01

    Full Text Available According to EC Regulation No 2073/2005, for food business operators that produce ready-to-eat (RTE product, it is crucial to be able to demonstrate if the product supports the growth of Listeria monocytogenes. The objective of the study was therefore to evaluate the behaviour of L. monocytogenes in sliced RTE turkey bresaola (made by cured turkey breast 4.5% NaCl, 1% sodium lactate, sodium nitrite 150 ppm and flavouring during the shelf life of the product, simulating a contamination during the slicing operation. Considering a shelf life of 90 days, as defined by manufacturer, the packages of sliced bresaola were stored at 5°C for 7 days and at 8°C for the remaining storage time (83 days. L. monocytogenes count decreased during storage test from 1.43/1.98 log cfu/g in the three batches tested to 1.03 log cfu/g in one batch and to undetectable levels in the other two batches. The results show that the investigated product is unable to support the growth of L. monocytogenes.

  4. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  5. Study of imaging time shortening in Whole Heart MRCA. Evaluation of slice thickness

    International Nuclear Information System (INIS)

    Iwai, Mitsuhiro; Tateishi, Toshiki; Takeda, Soji; Hayashi, Ryuji

    2005-01-01

    A series of examinations in cardiac MR imaging, such as cine, perfusion, MR coronary angiography (MRCA) and viability, is generally known as One Stop Cardiac Examination. It takes about 40 to 60 minutes to perform One Stop Cardiac Examination, and Whole Heart MRCA accounts for most of the examination time. Therefore, we aimed to shorten imaging time of Whole Heart MRCA, especially in a large imaging area such as that in the case of the postoperative evaluation of a bypass graft, by investigating the depiction of a diameter of mimic blood vessels as changing the slice thickness of Whole Heart MRCA. The results showed that the maximum slice thickness of about 1 mm was excellent considering the diameters of actual coronary arteries are about 3 mm. In this study, we could grasp the relationships among slice thickness of Whole Heart MRCA, the diameter of a blood vessel, and shortened examination time. We suggested that it was useful for selecting the suitable sequence depending on a patient's conditions. (author)

  6. The effect of ultraviolet treatment on enzymatic activity and total phenolic content of minimally processed potato slices.

    Science.gov (United States)

    Teoh, Li Shing; Lasekan, Ola; Adzahan, Noranizan Mohd; Hashim, Norhashila

    2016-07-01

    In this work, potato slices were exposed to different doses of UV-C irradiation (i.e. 2.28, 6.84, 11.41, and 13.68 kJ m -2 ) with or without pretreatment [i.e. ascorbic acid and calcium chloride (AACCl) dip] and stored at 4 ± 1 °C. Changes in enzymatic activities of polyphenol oxidase (PPO), peroxidase (POD) and phenylalanine ammonia lyase (PAL), as well as total phenolic content (TPC) were investigated after 0, 3, 7 and 10 days of storage. Results showed that untreated and UV-C treated potato slices at 13.68 kJ m -2 dosage level showed significantly higher PPO, POD and PAL activities. Conversely, untreated potato slices showed the lowest TPC during storage period. Potato slices subjected to AACCl dip plus UV-C at 6.84 kJ m -2 produced lower PPO, POD and PAL activities, as well as maintained a high TPC during storage.

  7. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  8. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  9. The accuracy of ventricular volume measurement and the optimal slice thickness by using multislice helical computed tomography

    International Nuclear Information System (INIS)

    Cui Wei; Guo Yuyin

    2005-01-01

    Objective: To determine the optimal slice thickness for ventricular volume measurement by tomographic multislice Simpson's method and to evaluate the accuracy of ventricular volume measured by multislice helical computed tomography (MSCT) in human ventricular casts. Methods: Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned with MSCT scanner by using a scanning protocol similar to clinical practice. A series of LV and RV short-axis images were reconstructed with slice thickness of 2 mm, 3.5 mm, 5 mm, 7 mm, and 10 mm, respectively. Multislice Simpson's method was used to calculate LV and RV volumes and true cast volume was determined by water displacement. Results: The true LV and RV volumes were (55.57 ± 28.91) ml, and (64.23 ± 24.51) ml, respectively. The calculated volumes from different slice thickness ranged from (58.78 ± 28.93) ml to (68.15 ± 32.57) ml for LV casts, and (74.45 ± 27.81) ml to (88.14 ± 32.91) ml for RV casts, respectively. Both the calculated LV and RV volumes correlated closely with the corresponding true volumes (all r > 0.95, P<0.001), but overestimated the corresponding true volume by (3.21 ± 5.95) to (12.58 ± 8.56) ml for LV and (10.22 ± 8.45) to (23.91 ± 12.24) ml for RV (all P<0.01). There was a close correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.001). However, when slice thickness was reduced to 5.0 mm, the overestimation became nonsignificant for slice thickness through 2.0 mm to 5.0 mm, and also for both LV and RV volume measurements. Conclusion: Both LV and RV volumes can be accurately calculated with MSCT. A 5 mm slice thickness is enough and most efficient for accurate measurement of LV and RV volume. (authors)

  10. Effects of chemical composite, puffing temperature and intermediate moisture content on physical properties of potato and apple slices

    Science.gov (United States)

    Tabtaing, S.; Paengkanya, S.; Tanthong, P.

    2017-09-01

    Puffing technique is the process that can improve texture and volumetric of crisp fruit and vegetable. However, the effect of chemical composite in foods on puffing characteristics is still lack of study. Therefore, potato and apple slices were comparative study on their physical properties. Potato and apple were sliced into 2.5 mm thickness and 2.5 cm in diameter. Potato slices were treated by hot water for 2 min while apple slices were not treatment. After that, they were dried in 3 steps. First step, they were dried by hot air at temperature of 90°C until their moisture content reached to 30, 40, and 50 % dry basis. Then they were puffed by hot air at temperature of 130, 150, and 170°C for 2 min. Finally, they were dried again by hot air at temperature of 90°C until their final moisture content reached to 4% dry basis. The experimental results showed that chemical composite of food affected on physical properties of puffed product. Puffed potato had higher volume ratio than those puffed apple because potato slices contains starch. The higher starch content provided more hard texture of potato than those apples. Puffing temperature and moisture content strongly affected on the color, volume ratio, and textural properties of puffed potato slices. In addition, the high drying rate of puffed product observed at high puffing temperature and higher moisture content.

  11. Influence of 60Co γ irradiation pre-treatment on characteristics of hot air drying sweet potato slices

    International Nuclear Information System (INIS)

    Jiang Ning; Liu Chunquan; Li Dajing; Liu Xia; Yan Qimei

    2012-01-01

    The influences of irradiation, hot air temperature and thicknesses of the slices on the characters of dehydration and surface temperature of 60 Co γ-rays irradiated sweet potato were investigated. Meanwhile, microscopic observation and determination of water activity of irradiated sweet potato were conducted. The results show that the drying rate and the surface temperature rose with the increasing of irradiation dose. When the dry basis moisture content was 150%, the drying rate of the samples were 1.92, 1.97, 2.05, 2.28, 3.12% /min while the irradiation dose were 0, 2, 5, 8, 10 kGy, and the surface temperature were 48.5 ℃, 46.3℃, 44.5 ℃, 42.2 ℃, 41.5 ℃, respectively. With higher air temperature and thinner of the sweet potato slices, the dehydration of the irradiated sweet potato slices were faster. The drying speed of sweet potato slices at 85 ℃ was 170 min faster than that of 65 ℃. The drying speed of 7 mm sweet potato slices was 228 min faster than that of 3 mm sample. The cell wall and the vacuole of the sweet potato slices were broken after irradiation, and its water activity increased with the increase is radiation dose. The water activity of the irradiated samples were 0.92, 0.945, 0.958, 0.969, 0.979 with the irradiation doses of 0, 2, 5, 8, 10 kGy, respectively. The hot air drying rate, surface temperature and water activity of sweet potato are significantly impacted by irradiation. The conclusion provides a theoretical foundation for further processing technology of combined radiation and hot air drying sweet potato. (authors)

  12. Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

    International Nuclear Information System (INIS)

    Chan, Heang-Ping; Wu Yita; Sahiner, Berkman; Wei, Jun; Helvie, Mark A.; Zhang Yiheng; Moore, Richard H.; Kopans, Daniel B.; Hadjiiski, Lubomir; Way, Ted

    2010-01-01

    Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 deg. arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19

  13. IRAS galaxies and the large-scale structure in the CfA slice

    Science.gov (United States)

    Babul, Arif; Postman, Marc

    1990-01-01

    The spatial distributions of the IRAS and the optical galaxies in the first CfA slice are compared. The IRAS galaxies are generally less clustered than optical ones, but their distribution is essentially identical to that of late-type optical galaxies. The discrepancy between the clustering properties of the IRAS and optical samples in the CfA slice region is found to be entirely due to the paucity of IRAS galaxies in the core of the Coma cluster. The spatial distributions of the IRAS and the optical galaxies, both late and early types, outside the dense core of the Coma cluster are entirely consistent with each other. This conflicts with the prediction of the linear biasing scenario.

  14. Redshifts for fainter galaxies in the first CfA survey slice. II

    Science.gov (United States)

    Wegner, Gary; Thorstensen, John R.; Kurtz, Michael J.; Geller, Margaret J.; Huchra, John P.

    1990-01-01

    Redshifts were measured for 96 galaxies in right ascension alpha between 8h and 17h declination delta between 30 and 31 deg, and with m(Zwicky) in the range 15.6-15.7. These correspond to 94 of the 96 entries in the Zwicky-Nilson merged catalog. The declination range delta between 29 deg and 31 deg is now complete to m(Zwicky) = 15.7. The structures in the first 6-deg-wide slice of the Center for Astrophysics redshift survey slice (delta between 26.5 and 32.5 deg are clearly defined in the 2-deg-wide slightly deeper sample; the fainter galaxies trace the structures defined by the brighter ones.

  15. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  16. Re-use of Low Bandwidth Equipment for High Bit Rate Transmission Using Signal Slicing Technique

    DEFF Research Database (Denmark)

    Wagner, Christoph; Spolitis, S.; Vegas Olmos, Juan José

    : Massive fiber-to-the-home network deployment requires never ending equipment upgrades operating at higher bandwidth. We show effective signal slicing method, which can reuse low bandwidth opto-electronical components for optical communications at higher bit rates.......: Massive fiber-to-the-home network deployment requires never ending equipment upgrades operating at higher bandwidth. We show effective signal slicing method, which can reuse low bandwidth opto-electronical components for optical communications at higher bit rates....

  17. Thin slices of friendship: do non-verbal behaviors predict first impressions during getting acquainted interactions?

    OpenAIRE

    Urgancı, Betül

    2017-01-01

    Cataloged from PDF version of article. Thesis (M.S.): Bilkent University, Department of Psychology, İhsan Doğramacı Bilkent University, 2017. Includes bibliographical references (leaves 28-32). Does a very brief observation of a person predict first impressions? Prior research has shown that these brief observations, called thin slices, predict many psychological outcomes such as individual performance. However, there is a not much research investigating whether thin slices predict f...

  18. Experimental study of multi-slice CT for the evaluation of atherosclerotic plaques

    International Nuclear Information System (INIS)

    Tang Xiang; Lv Bin; Wu Wenhui; Lu Jinguo; Dai Ruping; Bai Hua; Tang Yue; Lv Fengying; Jiang Shiliang

    2009-01-01

    Objective: To evaluate the diagnostic values of MSCT for detecting atherosclerotic plaques on New Zealand rabbits models in comparison with pathologic results. Methods: Fifteen New Zealand rabbits were enrolled in this study, including 5 with balloon injury and high-fat diet (group A), 5 with high-fat diet only (group B) and 5 with regular feed (group C). 16th week late, contrast-enhanced MSCT scan was performed in all rabbits with 16 slice MSCT (16-MSCT) in group A and 64 slice MSCT (64-MSCT) in group B and C. The CT and pathological findings were compared in a double-blind manner. The sensitivities and specificities of 16-MSCT and 64-MSCT for detecting atherosclerotic plaques were evaluated by using Fisher test and χ 2 test. Results: Sixty and seventy-five images on 16-MSCT and 64-MSCT had corresponding pathological slices. The sensitivities for the detection of plaques on 16-MSCT and 64-MSCT were 41.5% (22/53) and 64.9% (24/37), and specificities of 85.7% (6/7) and 89.5% (34/38), respectively. Conclusions: 64-MSCT has a higher sensitivity in the detection of atherosclerotic plaques than 16-MSCT. Both scanners can be used to preclude the diagnosis of atherosclerosis. (authors)

  19. Cells in human postmortem brain tissue slices remain alive for several weeks in culture

    NARCIS (Netherlands)

    Verwer, Ronald W. H.; Hermens, Wim T. J. M. C.; Dijkhuizen, PaulaA; ter Brake, Olivier; Baker, Robert E.; Salehi, Ahmad; Sluiter, Arja A.; Kok, Marloes J. M.; Muller, Linda J.; Verhaagen, Joost; Swaab, Dick F.

    2002-01-01

    Animal models for human neurological and psychiatric diseases only partially mimic the underlying pathogenic processes. Therefore, we investigated the potential use of cultured postmortem brain tissue from adult neurological patients and controls. The present study shows that human brain tissue

  20. Bacteriological Quality of Dried Sliced Beef (Kilishi) Sold In Ilorin ...

    African Journals Online (AJOL)

    DR. MIKE HORSFALL

    ABSTRACT: The bacteriological quality of dried sliced beef (kilishi) obtained from three selling points in. Ilorin metropolis was determined in order to ascertain its safety. The total bacterial count, Enterobacteriaceae count, Staphylococcus aureus count and E.coli counts were used as index of bacteriological quality. Samples.

  1. Slices: A shape-proxy based on planar sections

    KAUST Repository

    McCrae, James

    2011-12-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours of intersection of planes with a 3D object, for creating shape abstractions, motivated by their popularity in art and engineering. We first perform a user study to show that humans do define consistent and similar planar section proxies for common objects. Interestingly, we observe a strong correlation between user-defined planes and geometric features of objects. Further we show that the problem of finding the minimum set of planes that capture a set of 3D geometric shape features is both NP-hard and not always the proxy a user would pick. Guided by the principles inferred from our user study, we present an algorithm that progressively selects planes to maximize feature coverage, which in turn influence the selection of subsequent planes. The algorithmic framework easily incorporates various shape features, while their relative importance values are computed and validated from the user study data. We use our algorithm to compute planar slices for various objects, validate their utility towards object abstraction using a second user study, and conclude showing the potential applications of the extracted planar slice shape proxies.

  2. Bulk Fields and Supersymmetry in a Slice of AdS

    CERN Document Server

    Gherghetta, Tony; Gherghetta, Tony; Pomarol, Alex

    2000-01-01

    Five-dimensional models where the bulk is a slice of AdS have the virtue of solving the hierarchy problem. The electroweak scale is generated by a ``warp'' factor of the induced metric on the brane where the standard model fields live. However, it is not necessary to confine the standard model fields on the brane and we analyze the possibility of having the fields actually living in the slice of AdS. Specifically, we study the behaviour of fermions, gauge bosons and scalars in this geometry and their implications on electroweak physics. These scenarios can provide an explanation of the fermion mass hierarchy by warp factors. We also consider the case of supersymmetry in the bulk, and analyze the conditions on the mass spectrum. Finally, a model is proposed where the warp factor generates a small (TeV) supersymmetry-breaking scale, with the gauge interactions mediating the breaking to the scalar sector.

  3. A model for the parabolic slices Per1(e2πip/q) in moduli space of quadratic rational maps

    DEFF Research Database (Denmark)

    Uhre, Eva

    2010-01-01

    The notion of relatedness loci in the parabolic slices Per1(e2πip/q) in moduli space of quadratic rational maps is introduced. They are counterparts of the disconnectedness or escape locus in the slice of quadratic polynomials. A model for these loci is presented, and a strategy of proof of the f......The notion of relatedness loci in the parabolic slices Per1(e2πip/q) in moduli space of quadratic rational maps is introduced. They are counterparts of the disconnectedness or escape locus in the slice of quadratic polynomials. A model for these loci is presented, and a strategy of proof...... of the faithfulness of the model is given....

  4. Drying kinetics of whole and sliced turmeric rhizomes (Curcuma longa L. in a solar conduction dryer

    Directory of Open Access Journals (Sweden)

    A. Borah

    2015-09-01

    Full Text Available Drying of turmeric was carried out in a solar conduction dryer (SCD. Drying air temperature was achieved around 39–51 °C for an ambient temperature in the range of 25–28 °C. Moisture content from 78.65% (wb, was reduced to 6.36% (wb and 5.50% (wb for solid and sliced samples respectively in 12 h effective drying time. Drying curve of sliced samples showed more uniform falling in comparison to that of whole samples. The average effective moisture diffusivity was found to be 1.852 × 10−10 m2 s−1 for slab samples and 1.456 × 10−10 m2 s−1 for solid samples. Out of four models tried for simulation, Page model was found as best fitted thin layer drying model when simulation was done for all the drying data. The overall thermal efficiency of the dryer was found to be 55%. Drying of sliced rhizomes showed better drying kinetics and effective drying time could be reduced by slicing instead of drying in whole form.

  5. Use of pattern recognition for unaliasing simultaneously acquired slices in simultaneous multislice MR fingerprinting.

    Science.gov (United States)

    Jiang, Yun; Ma, Dan; Bhat, Himanshu; Ye, Huihui; Cauley, Stephen F; Wald, Lawrence L; Setsompop, Kawin; Griswold, Mark A

    2017-11-01

    The purpose of this study is to accelerate an MR fingerprinting (MRF) acquisition by using a simultaneous multislice method. A multiband radiofrequency (RF) pulse was designed to excite two slices with different flip angles and phases. The signals of two slices were driven to be as orthogonal as possible. The mixed and undersampled MRF signal was matched to two dictionaries to retrieve T 1 and T 2 maps of each slice. Quantitative results from the proposed method were validated with the gold-standard spin echo methods in a phantom. T 1 and T 2 maps of in vivo human brain from two simultaneously acquired slices were also compared to the results of fast imaging with steady-state precession based MRF method (MRF-FISP) with a single-band RF excitation. The phantom results showed that the simultaneous multislice imaging MRF-FISP method quantified the relaxation properties accurately compared to the gold-standard spin echo methods. T 1 and T 2 values of in vivo brain from the proposed method also matched the results from the normal MRF-FISP acquisition. T 1 and T 2 values can be quantified at a multiband acceleration factor of two using our proposed acquisition even in a single-channel receive coil. Further acceleration could be achieved by combining this method with parallel imaging or iterative reconstruction. Magn Reson Med 78:1870-1876, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Metabolic Characterization of Acutely Isolated Hippocampal and Cerebral Cortical Slices Using [U-(13)C]Glucose and [1,2-(13)C]Acetate as Substrates

    DEFF Research Database (Denmark)

    McNair, Laura F; Kornfelt, Rasmus; Walls, Anne B

    2017-01-01

    Brain slice preparations from rats, mice and guinea pigs have served as important tools for studies of neurotransmission and metabolism. While hippocampal slices routinely have been used for electrophysiology studies, metabolic processes have mostly been studied in cerebral cortical slices. Few...

  7. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  8. Effect of superficial radial nerve stimulation on the activity of nigro-striatal dopaminergic neurons in the cat: role of cutaneous sensory input

    International Nuclear Information System (INIS)

    Nieoullon, A.; Dusticier, N.

    1982-01-01

    The release of 3 H-dopamine (DA) continuously synthesized from 3 H-thyrosine was measured in the caudate nucleus (CN) and in the substantia nigra (SN) in both sides of the brain during electrical stimulation of the superficial radial nerve in cats lightly anaesthetized with halothane. Use of appropriate electrophysiologically controlled stimulation led to selective activation of low threshold afferent fibers whereas high stimulation activated all cutaneous afferents. Results showed that low threshold fiber activation induced a decreased dopaminergic activity in CN contralateral to nerve stimulation and a concomitant increase in dopaminergic activity on the ipsilateral side. Stimulation of group I and threshold stimulation of group II afferent fibers induced changes in the release of 3 H-DA mainly on the contralateral CN and SN and in the ipsilateral CN. High stimulation was followed by a general increase of the neurotransmitter release in the four structures. This shows that the nigro-striatal dopaminergic neurons are mainly-if not exclusively-controlled by cutaneous sensory inputs. This control, non-specific when high threshold cutaneous fibers are also activated. Such activations could contribute to restablish sufficient release of DA when the dopaminergic function is impaired as in Parkinson's disease. (Author)

  9. Effect of superficial radial nerve stimulation on the activity of nigro-striatal dopaminergic neurons in the cat: role of cutaneous sensory input

    Energy Technology Data Exchange (ETDEWEB)

    Nieoullon, A; Dusticier, N [Centre National de la Recherche Scientifique, 13 - Marseille (France). Inst. de Neurophysiologie et Psychophysiologie

    1982-01-01

    The release of /sup 3/H-dopamine (DA) continuously synthesized from /sup 3/H-thyrosine was measured in the caudate nucleus (CN) and in the substantia nigra (SN) in both sides of the brain during electrical stimulation of the superficial radial nerve in cats lightly anaesthetized with halothane. Use of appropriate electrophysiologically controlled stimulation led to selective activation of low threshold afferent fibers whereas high stimulation activated all cutaneous afferents. Results showed that low threshold fiber activation induced a decreased dopaminergic activity in CN contralateral to nerve stimulation and a concomitant increase in dopaminergic activity on the ipsilateral side. Stimulation of group I and threshold stimulation of group II afferent fibers induced changes in the release of /sup 3/H-DA mainly on the contralateral CN and SN and in the ipsilateral CN. High stimulation was followed by a general increase of the neurotransmitter release in the four structures. This shows that the nigro-striatal dopaminergic neurons are mainly-if not exclusively-controlled by cutaneous sensory inputs. This control, non-specific when high threshold cutaneous fibers are also activated. Such activations could contribute to reestablish sufficient release of DA when the dopaminergic function is impaired as in Parkinson's disease.

  10. Dedifferentiation of intrinsic response properties of motoneurons in organotypic cultures of the spinal cord of the adult turtle

    DEFF Research Database (Denmark)

    Perrier, J.F.; Noraberg, J.; Simon, M.

    2000-01-01

    Explant cultures from the spinal cord of adult turtles were established and used to study the sensitivity of the intrinsic response properties of motoneurons to the changes in connectivity and milieu imposed by isolation in culture. Transverse sections 700 microm thick were explanted on cover slips...... the ability to fire repetitively. By the second week in culture, a fraction of motoneurons displayed fast and slow transient outward rectification and low-threshold calcium spikes, features not seen in turtle motoneurons in acute slices. On the other hand, properties mediated by L-type Ca2+ channels...

  11. IMF-Slices for GPR Data Processing Using Variational Mode Decomposition Method

    Directory of Open Access Journals (Sweden)

    Xuebing Zhang

    2018-03-01

    Full Text Available Using traditional time-frequency analysis methods, it is possible to delineate the time-frequency structures of ground-penetrating radar (GPR data. A series of applications based on time-frequency analysis were proposed for the GPR data processing and imaging. With respect to signal processing, GPR data are typically non-stationary, which limits the applications of these methods moving forward. Empirical mode decomposition (EMD provides alternative solutions with a fresh perspective. With EMD, GPR data are decomposed into a set of sub-components, i.e., the intrinsic mode functions (IMFs. However, the mode-mixing effect may also bring some negatives. To utilize the IMFs’ benefits, and avoid the negatives of the EMD, we introduce a new decomposition scheme termed variational mode decomposition (VMD for GPR data processing for imaging. Based on the decomposition results of the VMD, we propose a new method which we refer as “the IMF-slice”. In the proposed method, the IMFs are generated by the VMD trace by trace, and then each IMF is sorted and recorded into different profiles (i.e., the IMF-slices according to its center frequency. Using IMF-slices, the GPR data can be divided into several IMF-slices, each of which delineates a main vibration mode, and some subsurface layers and geophysical events can be identified more clearly. The effectiveness of the proposed method is tested using synthetic benchmark signals, laboratory data and the field dataset.

  12. Higher transport and metabolism of glucose in astrocytes compared with neurons: a multiphoton study of hippocampal and cerebellar tissue slices.

    Science.gov (United States)

    Jakoby, Patrick; Schmidt, Elke; Ruminot, Iván; Gutiérrez, Robin; Barros, L Felipe; Deitmer, Joachim W

    2014-01-01

    Glucose is the most important energy substrate for the brain, and its cellular distribution is a subject of great current interest. We have employed fluorescent glucose probes, the 2-deoxy-D-glucose derivates 6- and 2-([N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl) amino]-2-deoxy-D-glucose) (2-NBDG), to measure transport and metabolism of glucose in acute slices of mouse hippocampus and cerebellum. In the hippocampus, 6-NBDG, which is not metabolized and hence indicates glucose transport, was taken up faster in astrocyte-rich layers (Stratum radiatum [S.r.], Stratum oriens [S.o.]) than in pyramidal cells. Metabolizable 2-NBDG showed larger signals in S.r. and S.o. than in Stratum pyramidale, suggesting faster glucose utilization rate in the astrocyte versus the neuronal compartment. Similarly, we found higher uptake and temperature-sensitive metabolism of 2-NBDG in Bergmann glia when compared with adjacent Purkinje neurons of cerebellar slices. A comparison between 6-NBDG transport and glucose transport in cultured cells using a fluorescence resonance energy transfer nanosensor showed that relative to glucose, 6-NBDG is transported better by neurons than by astrocytes. These results indicate that the preferential transport and metabolism of glucose by glial cells versus neurons proposed for the hippocampus and cerebellum by ourselves (in vitro) and for the barrel cortex by Chuquet et al. (in vivo) is more pronounced than anticipated.

  13. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-06-07

    Jun 7, 2010 ... The purpose of the study is to evaluate the effect of iodine concentration of contrast material on detection of hepatocellular carcinoma with multi-slice spiral computed tomography (CT) by using double-arterial phase and portal venous phase enhanced scanning. Ninety-four (94) patients with hepatocellular ...

  14. [3H]Dopamine accumulation and release from striatal slices in young, mature and senescent rats

    International Nuclear Information System (INIS)

    Thompson, J.M.

    1981-01-01

    Examinations of [ 3 H]dopamine ([ 3 H]DA) release following KCl or amphetamine administration in striatal slices from young (7 month), mature (12 month) and senescent (24 month) Wistar rats showed no age-related changes. Further, the amount of [ 3 H]DA accumulated in the striatal slices showed no changes with age. Thus, previously reported age-related deficits in motor behavior (i.e. rotational) are not produced by changes in striatal DA accumulation or release. (Auth.)

  15. Improved sliced velocity map imaging apparatus optimized for H photofragments.

    Science.gov (United States)

    Ryazanov, Mikhail; Reisler, Hanna

    2013-04-14

    Time-sliced velocity map imaging (SVMI), a high-resolution method for measuring kinetic energy distributions of products in scattering and photodissociation reactions, is challenging to implement for atomic hydrogen products. We describe an ion optics design aimed at achieving SVMI of H fragments in a broad range of kinetic energies (KE), from a fraction of an electronvolt to a few electronvolts. In order to enable consistently thin slicing for any imaged KE range, an additional electrostatic lens is introduced in the drift region for radial magnification control without affecting temporal stretching of the ion cloud. Time slices of ∼5 ns out of a cloud stretched to ⩾50 ns are used. An accelerator region with variable dimensions (using multiple electrodes) is employed for better optimization of radial and temporal space focusing characteristics at each magnification level. The implemented system was successfully tested by recording images of H fragments from the photodissociation of HBr, H2S, and the CH2OH radical, with kinetic energies ranging from 3 eV. It demonstrated KE resolution ≲1%-2%, similar to that obtained in traditional velocity map imaging followed by reconstruction, and to KE resolution achieved previously in SVMI of heavier products. We expect it to perform just as well up to at least 6 eV of kinetic energy. The tests showed that numerical simulations of the electric fields and ion trajectories in the system, used for optimization of the design and operating parameters, provide an accurate and reliable description of all aspects of system performance. This offers the advantage of selecting the best operating conditions in each measurement without the need for additional calibration experiments.

  16. The relationship between image quality and CT dose index of multi-slice low-dose chest CT

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Shao Jiang; Shi Jingyun; You Zhengqian; Li Shijun; Xue Yongming

    2003-01-01

    Objective: To explore the rationality and possibility of multi-slice low-dose CT scan in the examination of the chest. Methods: (1) X-ray dose index measurement: 120 kV tube voltage, 0.75 s rotation, 8 mm and 3 mm slice thickness, and the tube current setting of 115.0, 40.0, 25.0, and 7.5 mAs were employed in every section. The X-ray radiation dose was measured and compared statistically. (2) phantom measurement of homogeneity and noise: The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm sections, and every slice was scanned using tube current of 115.0, 40.0, 25.0, and 7.5 mAs. Five same regions of interest were measured on every image. The homogeneity and noise level of CT were appraised. (3) The multi-slice low-dose CT in patients: 30 patients with mass and 30 with patch shadow in the lung were selected randomly. The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm slice thickness. 115.0, 40.0, 25.0, 15.0, and 7.5 mAs tube current were employed in each same slice. Otherwise, 15 cases with helical scan were examined using 190, 150, 40, 25, and 15 mAs tube current. The reconstruction images of MIP, MPR, CVR, HRCT, 3D, CT virtual endoscopy, and variety of interval reconstruction were compared. (4) Evaluation of image quality: CT images were evaluated by four doctors using single-blind method, and 3 degrees including normal image, image with few artifact, and image with excessive artifact, were employed and analyzed statistically. Results: (1) The CT dose index with 115.0 mAs tube current exceeded those of 40.0, 25.0, and 7.5 mAs by about 60%, 70%, and 85%, respectively. (2) The phantom measurement showed that the lower of CT dose the lower of homogeneity, the lower of CT dose the higher of noise level. (3) Result of image quality evaluation: The percentage of the normal image had no significant difference between 8 and 3 mm in 115, 40, and 25 mAs (P>0.05). Conclusion: Multi-slice low-dose chest CT technology may protect the patients and guarantee the

  17. Usefulness of thin slice target CT scan in detecting mediastinal and hilar lymphadenopathy

    International Nuclear Information System (INIS)

    Yoshida, Shoji; Maeda, Tomoho; Nishioka, Masatoshi

    1986-01-01

    Comparative study of target scan with the different slice thickness and scan modes was performed to evaluate the mediastinal and hilar lymphadenopathy. 20 cases in controls and 35 cases in lymphadenopathy were examined. To delineate mediastinal and hilar lymphadenopathy, the scan mode of standard target was most useful in contrast and sharpness. Thin slice thickness with 5 mm was necessary in detecting small lymphnode or contour and internal structure of enlarged lymphnode. Valuable estimation of 5 mm contiguous target scan was obtained in the subaortic node (no. 5), tracheobronchial node (no. 4), precarinal and subcarinal node (no. 7) and right hilar node (no. 12). (author)

  18. Characterization of the in vitro propagation of epileptiform electrophysiological activity in organotypic hippocampal slice cultures coupled to 3D microelectrode arrays

    DEFF Research Database (Denmark)

    Pisciotta, Marzia; Morgavi, Giovanna; Jahnsen, Henrik

    2010-01-01

    Dynamic aspects of the propagation of epileptiform activity have so far received little attention. With the aim of providing new insights about the spatial features of the propagation of epileptic seizures in the nervous system, we studied in vitro the initiation and propagation of traveling...... activity are completely coherent with respect to the activity originating in the CA3, while components at higher frequencies lose the coherence, possibly suggesting that the cellular mechanism mediating propagation of electrophysiological activity becomes ineffective for those firing rates exceeding...... epileptiform waves of electrophysiological activity in the hippocampus by means of substrate three-dimensional microelectrode arrays (MEAs) for extracellular measurements. Pharmacologically disinhibited hippocampal slices spontaneously generate epileptiform bursts mostly originating in CA3 and propagating...

  19. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT

    International Nuclear Information System (INIS)

    Kloeppel, R.; Kahn, T.; Schreiter, D.; Dietrich, J.; Josten, C.

    2002-01-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of ∼30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by ∼4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [de

  20. Thin slice impressions : How advertising evaluation depends on exposure duration

    NARCIS (Netherlands)

    Pieters, Rik; Elsen, M.; Wedel, M.

    The duration of exposures to advertising is often brief. Then, consumers can only obtain “thin slices” of information from the ads, such as which product and brand are being promoted. This research is the first to examine the influence that such thin slices of information have on ad and brand

  1. Mycoflora of sun-dried sweet potato (Ipomoea batatas L.) slices in ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-07-20

    Jul 20, 2009 ... The composition of the fungal species which will be es- tablished on exposed ... fungi associated with sun-dried sweet potato slices with a view to highlighting ..... Valero A, Sanchis V, Ramos AJ, Marin S (2007). Studies on the.

  2. Feasibility and resolution limits of opto-magnetic imaging of neural network activity in brain slices using color centers in diamond

    DEFF Research Database (Denmark)

    Karadas, Mürsel; Wojciechowski, Adam M.; Huck, Alexander

    2018-01-01

    We suggest a novel approach for wide-field imaging of the neural network dynamics of brain slices that uses highly sensitivity magnetometry based on nitrogen-vacancy (NV) centers in diamond. Invitro recordings in brain slices is a proven method for the characterization of electrical neural activi...... cell. Our results suggest that imaging of slice activity will be possible with the upcoming generation of NV magnetic field sensors, while single-shot imaging of planar cell activity remains challenging....

  3. Evaluation of hygiene practices and microbiological quality of cooked meat products during slicing and handling at retail.

    Science.gov (United States)

    Pérez-Rodríguez, F; Castro, R; Posada-Izquierdo, G D; Valero, A; Carrasco, E; García-Gimeno, R M; Zurera, G

    2010-10-01

    Cooked meat ready-to-eat products are recognized to be contaminated during slicing which, in the last years, has been associated with several outbreaks. This work aimed to find out possible relation between the hygiene practice taking place at retail point during slicing of cooked meat products in small and medium-sized establishments (SMEs) and large-sized establishments (LEs) and the microbiological quality of sliced cooked meat products. For that, a checklist was drawn up and filled in based on scoring handling practice during slicing in different establishments in Cordoba (Southern Spain). In addition, sliced cooked meats were analyzed for different microbiological indicators and investigated for the presence of Listeria spp. and Listeria monocytogenes. Results indicated that SMEs showed a more deficient handling practices compared to LEs. In spite of these differences, microbiological counts indicated similar microbiological quality in cooked meat samples for both types of establishments. On the other hand, Listeria monocytogenes and Listeria inocua were isolated from 7.35% (5/68) and 8.82% (6/68) of analyzed samples, respectively. Positive samples for Listeria spp. were found in establishments which showed acceptable hygiene levels, though contamination could be associated to the lack of exclusiveness of slicers at retail points. Moreover, Listeria spp presence could not be statistically linked to any microbiological parameters; however, it was observed that seasonality influenced significantly (Phygiene practices, focused specially on SMEs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  4. Aerosol-assisted extraction of silicon nanoparticles from wafer slicing waste for lithium ion batteries.

    Science.gov (United States)

    Jang, Hee Dong; Kim, Hyekyoung; Chang, Hankwon; Kim, Jiwoong; Roh, Kee Min; Choi, Ji-Hyuk; Cho, Bong-Gyoo; Park, Eunjun; Kim, Hansu; Luo, Jiayan; Huang, Jiaxing

    2015-03-30

    A large amount of silicon debris particles are generated during the slicing of silicon ingots into thin wafers for the fabrication of integrated-circuit chips and solar cells. This results in a significant loss of valuable materials at about 40% of the mass of ingots. In addition, a hazardous silicon sludge waste is produced containing largely debris of silicon, and silicon carbide, which is a common cutting material on the slicing saw. Efforts in material recovery from the sludge and recycling have been largely directed towards converting silicon or silicon carbide into other chemicals. Here, we report an aerosol-assisted method to extract silicon nanoparticles from such sludge wastes and their use in lithium ion battery applications. Using an ultrasonic spray-drying method, silicon nanoparticles can be directly recovered from the mixture with high efficiency and high purity for making lithium ion battery anode. The work here demonstrated a relatively low cost approach to turn wafer slicing wastes into much higher value-added materials for energy applications, which also helps to increase the sustainability of semiconductor material and device manufacturing.

  5. On the concordance genus of topologically slice knots

    OpenAIRE

    Hom, Jennifer

    2012-01-01

    The concordance genus of a knot K is the minimum Seifert genus of all knots smoothly concordant to K. Concordance genus is bounded below by the 4-ball genus and above by the Seifert genus. We give a lower bound for the concordance genus of K coming from the knot Floer complex of K. As an application, we prove that there are topologically slice knots with 4-ball genus equal to one and arbitrarily large concordance genus.

  6. Effects of irradiation and fumaric acid treatment on the inactivation of Listeria monocytogenes and Salmonella typhimurium inoculated on sliced ham

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyeon-Jeong; Lee, Ji-Hye [Department of Food Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Song, Kyung Bin, E-mail: kbsong@cnu.ac.kr [Department of Food Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of)

    2011-11-15

    To examine the effects of fumaric acid and electron beam irradiation on the inactivation of foodborne pathogens in ready-to-eat meat products, sliced ham was inoculated with Listeria monocytogenes and Salmonella typhimurium. The inoculated ham slices were treated with 0.5% fumaric acid or electron beam irradiation at 2 kGy. Fumaric acid treatment reduced the populations of L. monocytogenes and S. typhimurium by approximately 1 log CFU/g compared to control populations. In contrast, electron beam irradiation decreased the populations of S. typhimurium and L. monocytogenes by 3.78 and 2.42 log CFU/g, respectively. These results suggest that electron beam irradiation is a better and appropriate technique for improving the microbial safety of sliced ham. - Highlights: > We compare irradiation and fumaric acid treatment on the inactivation of pathogens. > We examine changes in the populations of L. monocytogenes and S. typhimurium. > Irradiation at 2 kGy is more effective in sliced ham than fumaric acid treatment. > Low-dose irradiation can improve the microbial safety of sliced ham during storage.

  7. Effects of irradiation and fumaric acid treatment on the inactivation of Listeria monocytogenes and Salmonella typhimurium inoculated on sliced ham

    International Nuclear Information System (INIS)

    Song, Hyeon-Jeong; Lee, Ji-Hye; Song, Kyung Bin

    2011-01-01

    To examine the effects of fumaric acid and electron beam irradiation on the inactivation of foodborne pathogens in ready-to-eat meat products, sliced ham was inoculated with Listeria monocytogenes and Salmonella typhimurium. The inoculated ham slices were treated with 0.5% fumaric acid or electron beam irradiation at 2 kGy. Fumaric acid treatment reduced the populations of L. monocytogenes and S. typhimurium by approximately 1 log CFU/g compared to control populations. In contrast, electron beam irradiation decreased the populations of S. typhimurium and L. monocytogenes by 3.78 and 2.42 log CFU/g, respectively. These results suggest that electron beam irradiation is a better and appropriate technique for improving the microbial safety of sliced ham. - Highlights: → We compare irradiation and fumaric acid treatment on the inactivation of pathogens. → We examine changes in the populations of L. monocytogenes and S. typhimurium. → Irradiation at 2 kGy is more effective in sliced ham than fumaric acid treatment. → Low-dose irradiation can improve the microbial safety of sliced ham during storage.

  8. mIoT Slice for 5G Systems: Design and Performance Evaluation.

    Science.gov (United States)

    Trivisonno, Riccardo; Condoluci, Massimo; An, Xueli; Mahmoodi, Toktam

    2018-02-21

    Network slicing is a key feature of the upcoming 5G networks allowing the design and deployment of customized communication systems to integrate services provided by vertical industries. In this context, massive Internet of Things (mIoT) is regarded as a compelling use case, both for its relevance from business perspective, and for the technical challenges it poses to network design. With their envisaged massive deployment of devices requiring sporadic connectivity and small data transmission, yet Quality of Service (QoS) constrained, mIoT services will need an ad-hoc end-to-end (E2E) slice, i.e., both access and core network with enhanced Control and User planes (CP/UP). After revising the key requirements of mIoT and identifying major shortcomings of previous generation networks, this paper presents and evaluates an E2E mIoT network slicing solution, featuring a new connectivity model overcoming the load limitations of legacy systems. Unique in its kind, this paper addresses mIoT requirements from an end-to-end perspective highlighting and solving, unlike most prior related work, the connectivity challenges posed to the core network. Results demonstrate that the proposed solution, reducing CP signaling and optimizing UP resource utilization, is a suitable candidate for next generation network standards to efficiently handle massive device deployment.

  9. Strain analysis in CRT candidates using the novel segment length in cine (SLICE) post-processing technique on standard CMR cine images.

    Science.gov (United States)

    Zweerink, Alwin; Allaart, Cornelis P; Kuijer, Joost P A; Wu, LiNa; Beek, Aernout M; van de Ven, Peter M; Meine, Mathias; Croisille, Pierre; Clarysse, Patrick; van Rossum, Albert C; Nijveldt, Robin

    2017-12-01

    Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. • Myocardial strain analysis could potentially improve patient selection for CRT. • Currently a well validated clinical approach to derive segmental strains is lacking. • The novel SLICE technique derives segmental strains from standard CMR cine images. • SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. • Future studies will focus on the prognostic value of SLICE in CRT candidates.

  10. Quality changes of sea bass slices wrapped with gelatin film incorporated with lemongrass essential oil.

    Science.gov (United States)

    Ahmad, Mehraj; Benjakul, Soottawat; Sumpavapol, Punnanee; Nirmal, Nilesh Prakash

    2012-04-16

    Microbiological, chemical and physical changes of sea bass slices wrapped with gelatin film incorporated with 25% (w/w) lemongrass essential oil (LEO) during storage of 12 days at 4 °C were investigated. Sea bass slices wrapped with LEO film had the retarded growth of lactic acid bacteria (LAB), psychrophilic bacteria and spoilage microorganisms including H₂S-producing bacteria and Enterobacteriaceae throughout storage of 12 days in comparison with the control and those wrapped with gelatin film without LEO (G film) (P<0.05). Lowered changes of colour, K value, total volatile base nitrogen (TVB) and TBARS value were also found in LEO film wrapped samples, compared with those wrapped with G film and control, respectively. Therefore, the incorporation of LEO into gelatin film could enhance the antimicrobial and antioxidative properties of the film, thereby maintaining the qualities and extending the shelf-life of the sea bass slices stored at refrigerated temperature. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

    International Nuclear Information System (INIS)

    Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas

    2006-01-01

    The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)

  12. Front-end data processing using the bit-sliced microprocessor

    International Nuclear Information System (INIS)

    Machen, D.R.

    1979-01-01

    A state-of-the-art computing device, based upon the high-speed bit-sliced microprocessor, was developed into hardware for front-end data processing in both control and experiment applications at the Los Alamos Scientific Laboratory. The CAMAC Instrumentation Standard provides the framework for the high-speed hardware, allowing data acquisition and processing to take place at the data source in a CAMAC crate. 5 figures

  13. Determining the proportion of coronary segments assessable on 16-slice CT coronary angiography: a brief report

    International Nuclear Information System (INIS)

    Soon, K. H.; Cox, N.; Eccleston, D.; Lim, Y.; Chaitowitz, I.; Bell, K. W.; Kelly, A-M.

    2007-01-01

    Computed tomography coronary angiography (CT-CA) is becoming a popular non-invasive coronary imaging method. We aimed to determine the proportion of coronary segments assessable on a 16-slice CT in comparison with conventional selective coronary angiography (SCA). We identified all patients who had both 16-slice CT-CA and recent SCA (less than 12 months) from March 2004 to July 2005. Two CT reporters blinded to SCA independently classified coronary segment assessability on CT-CA. A cardiologist blinded to CT findings classified assess-ability of coronary segments on SCA. Data were analysed using descriptive statistics and proportion of agreement. Ninety-five study pairs were included in the analysis. Of those, 1161 coronary segments were deemed assessable on SCA and 1103 segments (95%) were also assessable on CT-CA. Nonassessable segments on CT-CA were predominantly in the distal segments and branches of coronary arteries. Reasons for nonassessability were small calibre (48.3%), motion artefacts (20.7%) and poorly reconstructed segments (22.4%). The 16-slice CT was able to assess a high proportion of but not all coronary segments. Nonassessable segments were predominantly distal segments or branches of coronary arteries. Motion artefacts due to heart-rate changes, small calibre and poorly reconstructed images were main causes of nonassessability on 16-slice CT-CA

  14. Transmission of 2.5 Gbit/s Spectrum-sliced WDM System for 50 km Single-mode Fiber

    Science.gov (United States)

    Ahmed, Nasim; Aljunid, Sayed Alwee; Ahmad, R. Badlisha; Fadil, Hilal Adnan; Rashid, Mohd Abdur

    2011-06-01

    The transmission of a spectrum-sliced WDM channel at 2.5 Gbit/s for 50 km of single mode fiber using an system channel spacing only 0.4 nm is reported. We have investigated the system performance using NRZ modulation format. The proposed system is compared with conventional system. The system performance is characterized as the bit-error-rate (BER) received against the system bit rates. Simulation results show that the NRZ modulation format performs well for 2.5 Gbit/s system bit rates. Using this narrow channel spectrum-sliced technique, the total number of multiplexed channels can be increased greatly in WDM system. Therefore, 0.4 nm channel spacing spectrum-sliced WDM system is highly recommended for the long distance optical access networks, like the Metro Area Network (MAN), Fiber-to-the-Building (FTTB) and Fiber-to-the-Home (FTTH).

  15. Automated fetal brain segmentation from 2D MRI slices for motion correction.

    Science.gov (United States)

    Keraudren, K; Kuklisova-Murgasova, M; Kyriakopoulou, V; Malamateniou, C; Rutherford, M A; Kainz, B; Hajnal, J V; Rueckert, D

    2014-11-01

    Motion correction is a key element for imaging the fetal brain in-utero using Magnetic Resonance Imaging (MRI). Maternal breathing can introduce motion, but a larger effect is frequently due to fetal movement within the womb. Consequently, imaging is frequently performed slice-by-slice using single shot techniques, which are then combined into volumetric images using slice-to-volume reconstruction methods (SVR). For successful SVR, a key preprocessing step is to isolate fetal brain tissues from maternal anatomy before correcting for the motion of the fetal head. This has hitherto been a manual or semi-automatic procedure. We propose an automatic method to localize and segment the brain of the fetus when the image data is acquired as stacks of 2D slices with anatomy misaligned due to fetal motion. We combine this segmentation process with a robust motion correction method, enabling the segmentation to be refined as the reconstruction proceeds. The fetal brain localization process uses Maximally Stable Extremal Regions (MSER), which are classified using a Bag-of-Words model with Scale-Invariant Feature Transform (SIFT) features. The segmentation process is a patch-based propagation of the MSER regions selected during detection, combined with a Conditional Random Field (CRF). The gestational age (GA) is used to incorporate prior knowledge about the size and volume of the fetal brain into the detection and segmentation process. The method was tested in a ten-fold cross-validation experiment on 66 datasets of healthy fetuses whose GA ranged from 22 to 39 weeks. In 85% of the tested cases, our proposed method produced a motion corrected volume of a relevant quality for clinical diagnosis, thus removing the need for manually delineating the contours of the brain before motion correction. Our method automatically generated as a side-product a segmentation of the reconstructed fetal brain with a mean Dice score of 93%, which can be used for further processing. Copyright

  16. Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis

    Science.gov (United States)

    Roth, Don J.

    2013-01-01

    A software method has been developed that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography (CT). This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2D sheets (or flattened onion skins ) in addition to a series of top view slices and 3D volume rendering. The advantages of viewing the data in this fashion are as follows: (1) the use of standard and specialized image processing and analysis methods is facilitated having 2D array data versus a volume rendering; (2) accurate lateral dimensional analysis of flaws is possible in the unwrapped sheets versus volume rendering; (3) flaws in the part jump out at the inspector with the proper contrast expansion settings in the unwrapped sheets; and (4) it is much easier for the inspector to locate flaws in the unwrapped sheets versus top view slices for very thin cylinders. The method is fully automated and requires no input from the user except proper voxel dimension from the CT experiment and wall thickness of the part. The software is available in 32-bit and 64-bit versions, and can be used with binary data (8- and 16-bit) and BMP type CT image sets. The software has memory (RAM) and hard-drive based modes. The advantage of the (64-bit) RAM-based mode is speed (and is very practical for users of 64-bit Windows operating systems and computers having 16 GB or more RAM). The advantage of the hard-drive based analysis is one can work with essentially unlimited-sized data sets. Separate windows are spawned for the unwrapped/re-sliced data view and any image processing interactive capability. Individual unwrapped images and un -wrapped image series can be saved in common image formats. More information is available at http://www.grc.nasa.gov/WWW/OptInstr/ NDE_CT_CylinderUnwrapper.html.

  17. Effect of voluntary exercise and dietary protein levels on incorporation of 14C-leucine into protein by mice liver slices in vitro

    International Nuclear Information System (INIS)

    Yashiro, Masanori; Kimura, Shuichi

    1983-01-01

    The effect of voluntary exercise on incorporation of 14 C-leucine into protein by mice liver slices in vitro were examined with mice fed 4 %, 6 % and 20 % protein diets. The incorporation of 14 C-leucine increased as dietary protein levels decreased and was significantly higher in liver slices of exercise groups than in slices of non-exercise groups. (author)

  18. T1 mapping cardiovascular magnetic resonance imaging to detect myocarditis—Impact of slice orientation on the diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Bohnen, Sebastian, E-mail: s.bohnen@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Radunski, Ulf K., E-mail: u.radunski@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Lund, Gunnar K., E-mail: glund@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Tahir, Enver, E-mail: e.tahir@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Avanesov, Maxim, E-mail: m.avanesov@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Stehning, Christian, E-mail: christian.stehning@philips.com [Philips Research, Hamburg (Germany); Schnackenburg, Bernhard, E-mail: bernhard.schnackenburg@philips.com [Philips Healthcare Germany, Hamburg (Germany); Adam, Gerhard, E-mail: g.adam@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Blankenberg, Stefan, E-mail: s.blankenberg@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Muellerleile, Kai, E-mail: kamuellerleile@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany)

    2017-01-15

    Background: T1 mapping is a promising diagnostic tool to improve the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in patients with suspected myocarditis. However, there are currently no data on the potential influence of slice orientation on the diagnostic performance of CMR. Thus, we compared the diagnostic performance of global myocardial T1 and extracellular volume (ECV) values to differentiate patients with myocarditis from healthy individuals between different slice orientations. Methods: This study included 48 patients with clinically defined myocarditis and 13 healthy controls who underwent CMR at 1.5 T. A modified Look-Locker inversion-recovery (MOLLI) sequence was used for T1 mapping before and 15 min after administration of 0.075 mmol/kg Gadolinium-BOPTA. T1 mapping was performed on three short and on three long axes slices, respectively. Native T1, post-contrast T1 and extracellular volume (ECV) −BOPTA maps were calculated using a dedicated plug-in written for the OsiriX software and compared between the mean value of three short-axes slices (3SAX), the central short-axis (1SAX), the mean value of three long-axes slices (3LAX), the four-chamber view (4CH), the three-chamber view (3CH) and the two-chamber view (2CH). Results: There were significantly lower native T1 values on 3LAX (1081 ms (1037–1131 ms)) compared to 3SAX (1107 ms (1069–1143 ms), p = 0.0022) in patients with myocarditis, but not in controls (1026 ms (1009–1059 ms) vs. 1039 ms (1023–1055 ms), p = 0.2719). The areas under the curve (AUC) to discriminate between myocarditis and healthy controls by native myocardial T1 were 0.85 (p < 0.0001) on 3SAX, 0.85 (p < 0.0001) on 1SAX, 0.76 (p = 0.0002) on 3LAX, 0.70 (p = 0.0075) on 4CH, 0.72 (p = 0.0020) on 3CH and 0.75 (p = 0.0003) on 2CH. The AUCs for ECV-BOPTA were 0.83 (p < 0.0001) on 3 SAX, 0.82 (p < 0.0001) on 1SAX, 0.77 (p = 0.0005) on 3LAX, 0.71 (p = 0.0079) on 4CH, 0.69 (p = 0.0371) on 3CH and 0.75 (p = 0.0006) on

  19. T1 mapping cardiovascular magnetic resonance imaging to detect myocarditis—Impact of slice orientation on the diagnostic performance

    International Nuclear Information System (INIS)

    Bohnen, Sebastian; Radunski, Ulf K.; Lund, Gunnar K.; Tahir, Enver; Avanesov, Maxim; Stehning, Christian; Schnackenburg, Bernhard; Adam, Gerhard; Blankenberg, Stefan; Muellerleile, Kai

    2017-01-01

    Background: T1 mapping is a promising diagnostic tool to improve the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in patients with suspected myocarditis. However, there are currently no data on the potential influence of slice orientation on the diagnostic performance of CMR. Thus, we compared the diagnostic performance of global myocardial T1 and extracellular volume (ECV) values to differentiate patients with myocarditis from healthy individuals between different slice orientations. Methods: This study included 48 patients with clinically defined myocarditis and 13 healthy controls who underwent CMR at 1.5 T. A modified Look-Locker inversion-recovery (MOLLI) sequence was used for T1 mapping before and 15 min after administration of 0.075 mmol/kg Gadolinium-BOPTA. T1 mapping was performed on three short and on three long axes slices, respectively. Native T1, post-contrast T1 and extracellular volume (ECV) −BOPTA maps were calculated using a dedicated plug-in written for the OsiriX software and compared between the mean value of three short-axes slices (3SAX), the central short-axis (1SAX), the mean value of three long-axes slices (3LAX), the four-chamber view (4CH), the three-chamber view (3CH) and the two-chamber view (2CH). Results: There were significantly lower native T1 values on 3LAX (1081 ms (1037–1131 ms)) compared to 3SAX (1107 ms (1069–1143 ms), p = 0.0022) in patients with myocarditis, but not in controls (1026 ms (1009–1059 ms) vs. 1039 ms (1023–1055 ms), p = 0.2719). The areas under the curve (AUC) to discriminate between myocarditis and healthy controls by native myocardial T1 were 0.85 (p < 0.0001) on 3SAX, 0.85 (p < 0.0001) on 1SAX, 0.76 (p = 0.0002) on 3LAX, 0.70 (p = 0.0075) on 4CH, 0.72 (p = 0.0020) on 3CH and 0.75 (p = 0.0003) on 2CH. The AUCs for ECV-BOPTA were 0.83 (p < 0.0001) on 3 SAX, 0.82 (p < 0.0001) on 1SAX, 0.77 (p = 0.0005) on 3LAX, 0.71 (p = 0.0079) on 4CH, 0.69 (p = 0.0371) on 3CH and 0.75 (p = 0.0006) on

  20. Fourier analysis of heart SPECT slices: from remodelation to function?

    International Nuclear Information System (INIS)

    Zigman, M.; Prpic, H.; Lokner, V.

    1994-01-01

    The aim of this study was to determine character of the spatial distribution of marked erythrocytes in heart chambers, lungs and great blood vessels in relation to function of the left and right heart. Investigation included total of 142 subjects, 28 of which were without subjective and clinical signs of heart disease as well as 56 after myocardial infarction (30 of anterior localization, 26 of inferior infarction), 35 with predominant left heart disease (aortic valve disease, dilatative myocardiopathy, etc.) and 23 with predominant right heart disease (atrial septal defect, mitral valve disease). Radionuclide ventriculography (RNV) at rest, and thorax SPECT were performed in all subjects with 740 MBq Tc-99m after in vivo erythrocyte labelling with pyrophosphate. Ultrasound investigation was performed on all the subjects with heart disease and 87 of them underwent invasive cardiac investigation. RNV analysis revealed scintigraphic data on left and right ventricle: global ejection fraction (GEF), end-systolic volume (ESV), end-diastolic volume (EDV), fast tilling rate (FFR), fast emptying rate (FER) as well as regional wall motion shortening. Reconstruction of 64x64x8 SPECT images resulted in 3x64 slices (transversal, coronal and sagittal slices). Fourier analysis of 20-32 reconstructed slices in all three dimensions gave amplitude image of the intensity distribution of marked erythrocytes in heart chambers lungs and great blood vessels as well as phase display of spatial localization of regional amplitude values. Results of joint ROC curves constructed for detection, localization and character of heart disease in all subjects revealed significant clinical information content of SPECT data. Evaluation of RI retention using amplitude images in 3D provides insight in regional changes of volume, particular for atrial and lung involvement. (author)

  1. Analysis of lipid raft molecules in the living brain slices.

    Science.gov (United States)

    Kotani, Norihiro; Nakano, Takanari; Ida, Yui; Ito, Rina; Hashizume, Miki; Yamaguchi, Arisa; Seo, Makoto; Araki, Tomoyuki; Hojo, Yasushi; Honke, Koichi; Murakoshi, Takayuki

    2017-08-24

    Neuronal plasma membrane has been thought to retain a lot of lipid raft components which play important roles in the neural function. Although the biochemical analyses of lipid raft using brain tissues have been extensively carried out in the past 20 years, many of their experimental conditions do not coincide with those of standard neuroscience researches such as neurophysiology and neuropharmacology. Hence, the physiological methods for lipid raft analysis that can be compatible with general neuroscience have been required. Herein, we developed a system to physiologically analyze ganglioside GM1-enriched lipid rafts in brain tissues using the "Enzyme-Mediated Activation of Radical Sources (EMARS)" method that we reported (Kotani N. et al. Proc. Natl. Acad. Sci. U S A 105, 7405-7409 (2008)). The EMARS method was applied to acute brain slices prepared from mouse brains in aCSF solution using the EMARS probe, HRP-conjugated cholera toxin subunit B, which recognizes ganglioside GM1. The membrane molecules present in the GM1-enriched lipid rafts were then labeled with fluorescein under the physiological condition. The fluorescein-tagged lipid raft molecules called "EMARS products" distributed differentially among various parts of the brain. On the other hand, appreciable differences were not detected among segments along the longitudinal axis of the hippocampus. We further developed a device to label the lipid raft molecules in acute hippocampal slices under two different physiological conditions to detect dynamics of the lipid raft molecules during neural excitation. Using this device, several cell membrane molecules including Thy1, known as a lipid raft resident molecule in neurons, were confirmed by the EMARS method in living hippocampal slices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Self-Seeded RSOA-Fiber Cavity Lasers vs. ASE Spectrum-Sliced or Externally Seeded Transmitters—A Comparative Study

    Directory of Open Access Journals (Sweden)

    Simon A. Gebrewold

    2015-12-01

    Full Text Available Reflective semiconductor optical amplifier fiber cavity lasers (RSOA-FCLs are appealing, colorless, self-seeded, self-tuning and cost-efficient upstream transmitters. They are of interest for wavelength division multiplexed passive optical networks (WDM-PONs based links. In this paper, we compare RSOA-FCLs with alternative colorless sources, namely the amplified spontaneous emission (ASE spectrum-sliced and the externally seeded RSOAs. We compare the differences in output power, signal-to-noise ratio (SNR, relative intensity noise (RIN, frequency response and transmission characteristics of these three sources. It is shown that an RSOA-FCL offers a higher output power over an ASE spectrum-sliced source with SNR, RIN and frequency response characteristics halfway between an ASE spectrum-sliced and a more expensive externally seeded RSOA. The results show that the RSOA-FCL is a cost-efficient WDM-PON upstream source, borrowing simplicity and cost-efficiency from ASE spectrum slicing with characteristics that are, in many instances, good enough to perform short-haul transmission. To substantiate our statement and to quantitatively compare the potential of the three schemes, we perform data transmission experiments at 5 and 10 Gbit/s.

  3. Metabolic Characterization of Acutely Isolated Hippocampal and Cerebral Cortical Slices Using [U-13C]Glucose and [1,2-13C]Acetate as Substrates.

    Science.gov (United States)

    McNair, Laura F; Kornfelt, Rasmus; Walls, Anne B; Andersen, Jens V; Aldana, Blanca I; Nissen, Jakob D; Schousboe, Arne; Waagepetersen, Helle S

    2017-03-01

    Brain slice preparations from rats, mice and guinea pigs have served as important tools for studies of neurotransmission and metabolism. While hippocampal slices routinely have been used for electrophysiology studies, metabolic processes have mostly been studied in cerebral cortical slices. Few comparative characterization studies exist for acute hippocampal and cerebral cortical slices, hence, the aim of the current study was to characterize and compare glucose and acetate metabolism in these slice preparations in a newly established incubation design. Cerebral cortical and hippocampal slices prepared from 16 to 18-week-old mice were incubated for 15-90 min with unlabeled glucose in combination with [U- 13 C]glucose or [1,2- 13 C]acetate. Our newly developed incubation apparatus allows accurate control of temperature and is designed to avoid evaporation of the incubation medium. Subsequent to incubation, slices were extracted and extracts analyzed for 13 C-labeling (%) and total amino acid contents (µmol/mg protein) using gas chromatography-mass spectrometry and high performance liquid chromatography, respectively. Release of lactate from the slices was quantified by analysis of the incubation media. Based on the measured 13 C-labeling (%), total amino acid contents and relative activity of metabolic enzymes/pathways, we conclude that the slice preparations in the current incubation apparatus exhibited a high degree of metabolic integrity. Comparison of 13 C-labeling observed with [U- 13 C]glucose in slices from cerebral cortex and hippocampus revealed no significant regional differences regarding glycolytic or total TCA cycle activities. On the contrary, results from the incubations with [1,2- 13 C]acetate suggest a higher capacity of the astrocytic TCA cycle in hippocampus compared to cerebral cortex. Finally, we propose a new approach for assessing compartmentation of metabolite pools between astrocytes and neurons using 13 C-labeling (%) data obtained from

  4. Protective effect of Ganoderma lucidum polysaccharide against carbon tetrachloride-induced hepatic damage in precision-cut carp liver slices.

    Science.gov (United States)

    Liu, Yingjuan; Zhang, Chunyun; Du, Jinliang; Jia, Rui; Cao, Liping; Jeney, Galina; Teraoka, Hiroki; Xu, Pao; Yin, Guojun

    2017-10-01

    The aim of the present study was to investigate the protective effects of Ganoderma lucidum polysaccharide (GLPS) against carbon tetrachloride (CCl 4 )-induced hepatotoxicity in vitro in common carp. Precision-cut liver slices (PCLSs), which closely resemble the organ from which they are derived, were employed as an in vitro model system. GLPS (0.1, 0.3, and 0.6 mg/ml) was added to PCLS culture system before the exposure to 12 mM CCl 4 . The supernatants and slices were collected to detect molecular and biochemical responses to CCl 4 and PCLS treatments. The levels of CYP1A, CYP3A, and CYP2E1 were measured by ELISA; the mRNA expressions of TNF-α, IL-1β, IL-6, and iNOS were determined by RT-PCR; and the relative protein expressions of c-Rel and p65 were analyzed by western blotting. Results showed that GLPS inhibited the elevations of the marker enzymes (GOT, GPT, LDH) and MDA induced by CCl 4 ; it also enhanced the suppressed activity of antioxidant enzymes (SOD, CAT, GSH-Px, T-AOC). The treatment with GLPS resulted in significant downregulation of NF-κB and inflammatory cytokine mRNA levels and significant decreases in the hepatic protein levels of CYP1A, CYP3A, and CYP2E1. These results suggest that GLPS can protect CCl 4 -induced PCLS injury through inhibiting lipid peroxidation, elevating antioxidant enzyme activity, and suppressing immune inflammatory response.

  5. Examination of the structure-toxicity relationships of L-cysteine-S-conjugates of halogenated alkenes and their corresponding mercapturic acids in rat renal tissue slices.

    NARCIS (Netherlands)

    Stijntjes, G.J.; Commandeur, J.N.M.; te Koppele, J.M.; McGuinness, S; Gandolfi, A.J.; Vermeulen, N.P.E.

    1993-01-01

    Rat kidney slices were produced using a modified version of a mechanical tissue slicer. The slices were incubated with various concentrations of l-cysteine conjugates and mercapturic acids of halogenated alkenes in a submersion incubation system. The slices showed a time- and concentration-dependent

  6. Analysis of hepatic vein variations in healthy people with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Zhang Rong; Li Yong; Shen Jun; Zeng Weike; Li Jieting; Huang Suiqiao; Liang Biling; Liu Chao

    2007-01-01

    Objective: To analyze variations of hepatic vein in healthy people with 64-slice spiral CT. Methods: Seventy-five healthy subjects underwent multi-slice spiral computed (MSCT) hepatic venography. The anatomy of the junction of the hepatic veins with the inferior vena cava and the intrahepatic drainage territory of the hepatic veins and tributaries were evaluated. The hepatic veins were classified according to three anatomic classification (Nakamura's, Marcos's and Kawasaki's classification) methods respectively. Results: There was a common trunk of the middle and left hepatic veins before joining the IVC in 86.7% (65/75)of the cases. In 13.3% (10/75)of the cases, the three main hepatic veins joined the IVC separately. The ratios of Nakamma's classification type A, B, C of hepatic veins were 49.4% (37/75), 37.3% (28/75), and 13.3% (10/75) respectively. The ratios of Marcos's classification type A, B, C of hepatic veins were 56.0% (42/75), 24.0% (18/75), and 20.0% (15/75) respectively. The ratios of Kawasaki's classification type I, II of hepatic vein were 40.0% (30/75) and 60.0% (45/75). Conclusion: Multi-slice spiral CT hepatic venography can provide visualization of peripheral hepatic venous branches in details. (authors)

  7. Multi-slice MRI reveals heterogeneity in disease distribution along the length of muscle in Duchenne muscular dystrophy.

    Science.gov (United States)

    Chrzanowski, Stephen M; Baligand, Celine; Willcocks, Rebecca J; Deol, Jasjit; Schmalfuss, Ilona; Lott, Donovan J; Daniels, Michael J; Senesac, Claudia; Walter, Glenn A; Vandenborne, Krista

    2017-09-01

    Duchenne muscular dystrophy (DMD) causes progressive pathologic changes to muscle secondary to a cascade of inflammation, lipid deposition, and fibrosis. Clinically, this manifests as progressive weakness, functional loss, and premature mortality. Though insult to whole muscle groups is well established, less is known about the relationship between intramuscular pathology and function. Differences of intramuscular heterogeneity across muscle length were assessed using an ordinal MRI grading scale in lower leg muscles of boys with DMD and correlated to patient's functional status. Cross sectional T 1 weighted MRI images with fat suppression were obtained from ambulatory boys with DMD. Six muscles (tibialis anterior, extensor digitorum longus, peroneus, soleus, medial and lateral gastrocnemii) were graded using an ordinal grading scale over 5 slice sections along the lower leg length. The scores from each slice were combined and results were compared to global motor function and age. Statistically greater differences of involvement were observed at the proximal ends of muscle compared to the midbellies. Multi-slice assessment correlated significantly to age and the Vignos functional scale, whereas single-slice assessment correlated to the Vignos functional scale only. Lastly, differential disease involvement of whole muscle groups and intramuscular heterogeneity were observed amongst similar age subjects. A multi-slice ordinal MRI grading scale revealed that muscles are not uniformly affected, with more advanced disease visible near the tendons in a primarily ambulatory population with DMD. A geographically comprehensive evaluation of the heterogeneously affected muscle in boys with DMD may more accurately assess disease involvement.

  8. The rate of incorporation and degradation of phenylalanine-14C by tissue slices of roosters fed a phenylalanine-free diet

    International Nuclear Information System (INIS)

    Ishibashi, Teru; Kametaka, Masao

    1975-01-01

    To investigate the reason why adult roosters maintain nitrogen equilibrium on a phenylalanine-free diet for long periods, the rates of incorporation and of degradation of phenylalanine, tyrosine- and isoleucine- 14 C by tissue slices of roosters on the control, phenylalanine-free or isoleucine-free diets were measured. The degradation rate of isoleucine by liver and muscle slices decreased significantly for the isoleucine-free diet. However, the degradation rate of phenylalanine- 14 C by liver slices for the phenylalanine-free diet was not significantly lower than that for the control diet in contrast to the previous observation in vivo. The incorporation rates of 14 C into liver and muscle proteins were not affected by the dietary conditions in this experiment except in the case of phenylalanine- 14 C by muscle slices for the phenylalanine-free diet. (auth.)

  9. Vitamin C acts as a hepatoprotectant in carbofuran treated rat liver slices in vitro.

    Science.gov (United States)

    Jaiswal, Sunil Kumar; Gupta, Vivek Kumar; Ansari, Md Dilshad; Siddiqi, Nikhat J; Sharma, Bechan

    2017-01-01

    Carbamates, most commonly used pesticides in agricultural practices, have been reported to produce free radicals causing deleterious effects in animals. The present study was designed to assess the carbofuran induced oxidative stress in rat liver slices in vitro and also to evaluate protective role of vitamin C by incubating them in Krebs-Ringer HEPES Buffer (KRHB) containing incubation media (Williams medium E (WME) supplemented with glucose and antibiotics) with different concentrations of carbofuran. The results demonstrated that carbofuran caused significant increase in lipid peroxidation and inhibition in the activity of hepatic superoxide dismutase (SOD) in concentration dependent manner. The data with incubation medium reflected that carbofuran at lowest concentration caused an increase in SOD activity followed by its inhibition at higher concentration. Carbofuran treatment caused inhibition in the activity of catalase in liver slices and WME incubation medium. Pre-incubation of liver slices and the WME media with vitamin C restored the values of biochemical indices tested. The results indicated that carbofuran might induce oxidative stress in hepatocytes. The pretreatment with vitamin C may offer hepatoprotection from toxicity of pesticide at low concentration only.

  10. System Life Cycle Evaluation(SM) (SLiCE): harmonizing water treatment systems with implementers' needs.

    Science.gov (United States)

    Goodman, Joseph; Caravati, Kevin; Foote, Andrew; Nelson, Molly; Woods, Emily

    2013-06-01

    One of the methods proposed to improve access to clean drinking water is the mobile packaged water treatment system (MPWTS). The lack of published system performance comparisons combined with the diversity of technology available and intended operating conditions make it difficult for stakeholders to choose the system best suited for their application. MPWTS are often deployed in emergency situations, making selection of the appropriate system crucial to avoiding wasted resources and loss of life. Measurable critical-to-quality characteristics (CTQs) and a system selection tool for MPWTS were developed by utilizing relevant literature, including field studies, and implementing and comparing seven different MPWTS. The proposed System Life Cycle Evaluation (SLiCE) method uses these CTQs to evaluate the diversity in system performance and harmonize relevant performance with stakeholder preference via a selection tool. Agencies and field workers can use SLiCE results to inform and drive decision-making. The evaluation and selection tool also serves as a catalyst for communicating system performance, common design flaws, and stakeholder needs to system manufacturers. The SLiCE framework can be adopted into other emerging system technologies to communicate system performance over the life cycle of use.

  11. Assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images

    Directory of Open Access Journals (Sweden)

    Habibeh Farazdaghi

    2017-02-01

    Full Text Available Background and Aims: Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. The aim of this study was the assessment of sphenoid sinus volume in order to determine sexual identity, using multi-slice CT images. Materials and Methods: For volumetric analysis, axial paranasal sinus CT scan with 3-mm slice thickness was used. For this study, 80 images (40 women and 40 men older than 18 years were selected. For the assessment of sphenoid sinus volume, Digimizer software was used. The volume of sphenoid sinus was calculated using the following equation: v=∑ (area of each slice × thickness of each slice. Statistical analysis was performed by independent T-test. Results: The mean volume of sphenoid sinus was significantly greater in male gender (P=0.01.The assessed Cut off point was 9/35 cm3, showing that 63.4% of volume assessments greater than cut off point was supposed to be male and 64.1% of volumetry lesser than cut off point were female. Conclusion: According to the area under Roc curve (1.65%, sphenoid sinus volume is not an appropriate factor for differentiation of male and female from each other, which means the predictability of cut off point (9/35 cm3 is 65/1% close to reality.

  12. Difference in Uptake of Tetrodotoxin and Saxitoxins into Liver Tissue Slices among Pufferfish, Boxfish and Porcupinefish

    Directory of Open Access Journals (Sweden)

    Yuji Nagashima

    2018-01-01

    Full Text Available Although pufferfish of the family Tetraodontidae contain high levels of tetrodotoxin (TTX mainly in the liver, some species of pufferfish, boxfish of the family Ostraciidae, and porcupinefish of the family Diodontidae do not. To clarify the mechanisms, uptake of TTX and saxitoxins (STXs into liver tissue slices of pufferfish, boxfish and porcupinefish was examined. Liver tissue slices of the pufferfish (toxic species Takifugu rubripes and non-toxic species Lagocephalus spadiceus, L. cheesemanii and Sphoeroides pachygaster incubated with 50 µM TTX accumulated TTX (0.99–1.55 µg TTX/mg protein after 8 h, regardless of the toxicity of the species. In contrast, in liver tissue slices of boxfish (Ostracion immaculatus and porcupinefish (Diodon holocanthus, D. liturosus, D. hystrix and Chilomycterus reticulatus, TTX content did not increase with incubation time, and was about 0.1 µg TTX/mg protein. When liver tissue slices were incubated with 50 µM STXs for 8 h, the STXs content was <0.1 µg STXs/mg protein, irrespective of the fish species. These findings indicate that, like the toxic species of pufferfish T. rubripes, non-toxic species such as L. spadiceus, L. cheesemanii and S. pachygaster, potentially take up TTX into the liver, while non-toxic boxfish and porcupinefish do not take up either TTX or STXs.

  13. Improving the time efficiency of the Fourier synthesis method for slice selection in magnetic resonance imaging.

    Science.gov (United States)

    Tahayori, B; Khaneja, N; Johnston, L A; Farrell, P M; Mareels, I M Y

    2016-01-01

    The design of slice selective pulses for magnetic resonance imaging can be cast as an optimal control problem. The Fourier synthesis method is an existing approach to solve these optimal control problems. In this method the gradient field as well as the excitation field are switched rapidly and their amplitudes are calculated based on a Fourier series expansion. Here, we provide a novel insight into the Fourier synthesis method via representing the Bloch equation in spherical coordinates. Based on the spherical Bloch equation, we propose an alternative sequence of pulses that can be used for slice selection which is more time efficient compared to the original method. Simulation results demonstrate that while the performance of both methods is approximately the same, the required time for the proposed sequence of pulses is half of the original sequence of pulses. Furthermore, the slice selectivity of both sequences of pulses changes with radio frequency field inhomogeneities in a similar way. We also introduce a measure, referred to as gradient complexity, to compare the performance of both sequences of pulses. This measure indicates that for a desired level of uniformity in the excited slice, the gradient complexity for the proposed sequence of pulses is less than the original sequence. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. A simple water-immersion condenser for imaging living brain slices on an inverted microscope.

    Science.gov (United States)

    Prusky, G T

    1997-09-05

    Due to some physical limitations of conventional condensers, inverted compound microscopes are not optimally suited for imaging living brain slices with transmitted light. Herein is described a simple device that converts an inverted microscope into an effective tool for this application by utilizing an objective as a condenser. The device is mounted on a microscope in place of the condenser, is threaded to accept a water immersion objective, and has a slot for a differential interference contrast (DIC) slider. When combined with infrared video techniques, this device allows an inverted microscope to effectively image living cells within thick brain slices in an open perfusion chamber.

  15. Filter and slice thickness selection in SPECT image reconstruction

    International Nuclear Information System (INIS)

    Ivanovic, M.; Weber, D.A.; Wilson, G.A.; O'Mara, R.E.

    1985-01-01

    The choice of filter and slice thickness in SPECT image reconstruction as function of activity and linear and angular sampling were investigated in phantom and patient imaging studies. Reconstructed transverse and longitudinal spatial resolution of the system were measured using a line source in a water filled phantom. Phantom studies included measurements of the Data Spectrum phantom; clinical studies included tomographic procedures in 40 patients undergoing imaging of the temporomandibular joint. Slices of the phantom and patient images were evaluated for spatial of the phantom and patient images were evaluated for spatial resolution, noise, and image quality. Major findings include; spatial resolution and image quality improve with increasing linear sampling frequencies over the range of 4-8 mm/p in the phantom images, best spatial resolution and image quality in clinical images were observed at a linear sampling frequency of 6mm/p, Shepp and Logan filter gives the best spatial resolution for phantom studies at the lowest linear sampling frequency; smoothed Shepp and Logan filter provides best quality images without loss of resolution at higher frequencies and, spatial resolution and image quality improve with increased angular sampling frequency in the phantom at 40 c/p but appear to be independent of angular sampling frequency at 400 c/p

  16. Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT. Motion phantom study for volumetry

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Matsumoto, Takashi; Nakanishi, Shohzoh; Hamada, Seiki; Takahei, Kazunari; Naito, Hiroaki; Ogata, Yuji

    2002-01-01

    ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5 sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom. (author)

  17. Exposure of precision-cut rat liver slices to ethanol accelerates fibrogenesis

    NARCIS (Netherlands)

    Schaffert, Courtney S.; Duryee, Michael J.; Bennett, Robert G.; DeVeney, Amy L.; Tuma, Dean J.; Olinga, Peter; Easterling, Karen C.; Thiele, Geoffrey M.; Klassen, Lynell W.

    Schaffert CS, Duryee MJ, Bennett RG, DeVeney AL, Tuma DJ, Olinga P, Easterling KC, Thiele GM, Klassen LW. Exposure of precision-cut rat liver slices to ethanol accelerates fibrogenesis. Am J Physiol Gastrointest Liver Physiol 299: G661-G668, 2010. First published July 1, 2010; doi:

  18. Inter-slice motion correction using spatiotemporal interpolation for functional magnetic resonance imaging of the moving fetus

    OpenAIRE

    Limperopoulos, Catherine; You, Wonsang

    2017-01-01

    Fetal motion continues to be one of the major artifacts in in-utero functional MRI; interestingly few methods have been developed to address fetal motion correction. In this study, we propose a robust method for motion correction in fetal fMRI by which both inter-slice and inter-volume motion artifacts are jointly corrected. To accomplish this, an original volume is temporally split into odd and even slices, and then voxel intensities are spatially and temporally interpolated in the process o...

  19. Image quality dependence on thickness of sliced rat kidney taken by a simplest DEI construction

    International Nuclear Information System (INIS)

    Li Gang; Chen Zhihua; Wu Ziyu; Ando, M.; Pan Lin; Wang, J.Y.; Jiang, X.M.

    2005-01-01

    The excised rat kidney slices were investigated using a simplified diffraction-enhanced imaging (DEI) configuration with only two crystals: the first one working as monochromator and the second one working as analyzer in the Bragg geometry that was developed at Beijing Synchrotron Radiation Facility (BSRF). Many fine anatomic structures of the sliced rat kidneys with thickness of 2mm and 120μm can be distinguished clearly in the DEI images that were obtained at the shoulder of a rocking curve. The authors would like to emphasize that the thick and thin slices DEI provides very different images; in the thick sample only the structure with the big density gradient or that near the surface where X-ray comes out can be distinguished, while in the thin ones some fine structures, which can not be distinguished at the thick sample under the same condition, can be seen very clearly. The reason related with the counteraction of δ(x,y,z) gradient in the integral process along the X-ray path inside the thick sample is discussed

  20. Use of 60 Co gamma radiation to expend the shell life of packaged sliced loaves

    International Nuclear Information System (INIS)

    Nazato, R.E.S.

    1991-11-01

    The evaluation of conservation of sliced loaves (bread cut into slices). baked by five bakeries of Piracicaba, after gamma irradiation and maintained into polyethylene begs of low density, of 47,5 and 85 μm of thicknesses is shown. The sliced loaves were put into the bags and thermo-sealed by hand, like they were handled by the bakers. After this, they were irradiated with doses of 0.0: 2.0; 4.0; 6.0; 8.0 and 10.0 kGy of gamma radiation in a irradiation chamber of Cobalt-60 at a dose rate of 2,68 kGy per hour, at the room temperature (28 0 C). After irradiation the samples were maintained under at the room temperature (26 - 34 0 C), and humidity, as similar as possible to the conditions of the markets, bakeries and shops they were sold. The samples were evaluated every days and if any of them presented sign of contamination. It was threw away because it was inappropriate for human consumption. (author)

  1. Image quality dependence on thickness of sliced rat kidney taken by a simplest DEI construction

    Energy Technology Data Exchange (ETDEWEB)

    Li Gang [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China)]. E-mail: lig@ihep.ac.cn; Chen Zhihua [China-Japan Friendship Institute of Clinical Medical Science, Yinghua Rd., Beijing 100029 (China); Wu Ziyu [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China); Ando, M. [Photon Factory, KEK, Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Pan Lin [China-Japan Friendship Institute of Clinical Medical Science, Yinghua Rd., Beijing 100029 (China); Wang, J.Y. [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China); Jiang, X.M. [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China)

    2005-08-11

    The excised rat kidney slices were investigated using a simplified diffraction-enhanced imaging (DEI) configuration with only two crystals: the first one working as monochromator and the second one working as analyzer in the Bragg geometry that was developed at Beijing Synchrotron Radiation Facility (BSRF). Many fine anatomic structures of the sliced rat kidneys with thickness of 2mm and 120{mu}m can be distinguished clearly in the DEI images that were obtained at the shoulder of a rocking curve. The authors would like to emphasize that the thick and thin slices DEI provides very different images; in the thick sample only the structure with the big density gradient or that near the surface where X-ray comes out can be distinguished, while in the thin ones some fine structures, which can not be distinguished at the thick sample under the same condition, can be seen very clearly. The reason related with the counteraction of {delta}(x,y,z) gradient in the integral process along the X-ray path inside the thick sample is discussed.

  2. Slice-to-Volume Nonrigid Registration of Histological Sections to MR Images of the Human Brain

    Science.gov (United States)

    Osechinskiy, Sergey; Kruggel, Frithjof

    2011-01-01

    Registration of histological images to three-dimensional imaging modalities is an important step in quantitative analysis of brain structure, in architectonic mapping of the brain, and in investigation of the pathology of a brain disease. Reconstruction of histology volume from serial sections is a well-established procedure, but it does not address registration of individual slices from sparse sections, which is the aim of the slice-to-volume approach. This study presents a flexible framework for intensity-based slice-to-volume nonrigid registration algorithms with a geometric transformation deformation field parametrized by various classes of spline functions: thin-plate splines (TPS), Gaussian elastic body splines (GEBS), or cubic B-splines. Algorithms are applied to cross-modality registration of histological and magnetic resonance images of the human brain. Registration performance is evaluated across a range of optimization algorithms and intensity-based cost functions. For a particular case of histological data, best results are obtained with a TPS three-dimensional (3D) warp, a new unconstrained optimization algorithm (NEWUOA), and a correlation-coefficient-based cost function. PMID:22567290

  3. Slice-to-Volume Nonrigid Registration of Histological Sections to MR Images of the Human Brain

    Directory of Open Access Journals (Sweden)

    Sergey Osechinskiy

    2011-01-01

    Full Text Available Registration of histological images to three-dimensional imaging modalities is an important step in quantitative analysis of brain structure, in architectonic mapping of the brain, and in investigation of the pathology of a brain disease. Reconstruction of histology volume from serial sections is a well-established procedure, but it does not address registration of individual slices from sparse sections, which is the aim of the slice-to-volume approach. This study presents a flexible framework for intensity-based slice-to-volume nonrigid registration algorithms with a geometric transformation deformation field parametrized by various classes of spline functions: thin-plate splines (TPS, Gaussian elastic body splines (GEBS, or cubic B-splines. Algorithms are applied to cross-modality registration of histological and magnetic resonance images of the human brain. Registration performance is evaluated across a range of optimization algorithms and intensity-based cost functions. For a particular case of histological data, best results are obtained with a TPS three-dimensional (3D warp, a new unconstrained optimization algorithm (NEWUOA, and a correlation-coefficient-based cost function.

  4. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  5. Correlation between a 2D Channelized Hotelling Observer and Human Observers in a Low-contrast Detection Task with Multi-slice Reading in CT

    Science.gov (United States)

    Yu, Lifeng; Chen, Baiyu; Kofler, James M.; Favazza, Christopher P.; Leng, Shuai; Kupinski, Matthew A.; McCollough, Cynthia H.

    2017-01-01

    Purpose Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e. multi-slice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multi-slice reading, and to determine if the 2D model observer still correlate well with human observer performance in multi-slice reading. Methods A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at 5 dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multi-slice channelized Hotelling observer (CHO_MS), which integrates multi-slice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multi-slice viewing performance and the two CHO models. Results Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode (Pearson product-moment correlation coefficient R=0

  6. Precision-cut liver slices as a model for the early onset of liver fibrosis to test antifibrotic drugs

    Energy Technology Data Exchange (ETDEWEB)

    Westra, Inge M. [Division of Pharmacokinetics, Toxicology and Targeting, Department of Pharmacy, University of Groningen (Netherlands); Oosterhuis, Dorenda [Division of Pharmaceutical Technology and Biopharmacy, Department of Pharmacy, University of Groningen (Netherlands); Groothuis, Geny M.M. [Division of Pharmacokinetics, Toxicology and Targeting, Department of Pharmacy, University of Groningen (Netherlands); Olinga, Peter, E-mail: p.olinga@rug.nl [Division of Pharmaceutical Technology and Biopharmacy, Department of Pharmacy, University of Groningen (Netherlands)

    2014-01-15

    Induction of fibrosis during prolonged culture of precision-cut liver slices (PCLS) was reported. In this study, the use of rat PCLS was investigated to further characterize the mechanism of early onset of fibrosis in this model and the effects of antifibrotic compounds. Rat PCLS were incubated for 48 h, viability was assessed by ATP and gene expression of PDGF-B and TGF-β1 and the fibrosis markers Hsp47, αSma and Pcol1A1 and collagen1 protein expressions were determined. The effects of the antifibrotic drugs imatinib, sorafenib and sunitinib, PDGF-pathway inhibitors, and perindopril, valproic acid, rosmarinic acid, tetrandrine and pirfenidone, TGFβ-pathway inhibitors, were determined. After 48 h of incubation, viability of the PCLS was maintained and gene expression of PDGF-B was increased while TGF-β1 was not changed. Hsp47, αSma and Pcol1A1 gene expressions were significantly elevated in PCLS after 48 h, which was further increased by PDGF-BB and TGF-β1. The increased gene expression of fibrosis markers was inhibited by all three PDGF-inhibitors, while TGFβ-inhibitors showed marginal effects. The protein expression of collagen 1 was inhibited by imatinib, perindopril, tetrandrine and pirfenidone. In conclusion, the increased gene expression of PDGF-B and the down-regulation of fibrosis markers by PDGF-pathway inhibitors, together with the absence of elevated TGF-β1 gene expression and the limited effect of the TGFβ-pathway inhibitors, indicated the predominance of the PDGF pathway in the early onset of fibrosis in PCLS. PCLS appear a useful model for research of the early onset of fibrosis and for testing of antifibrotic drugs acting on the PDGF pathway. - Highlights: • During culture, fibrosis markers increased in precision-cut liver slices (PCLS). • Gene expression of PDGF-β was increased, while TGFβ was not changed in rat PCLS. • PDGF-pathway inhibitors down-regulated this increase of fibrosis markers. • TGFβ-pathway inhibitors had only

  7. The impact of computed tomography slice thickness on the assessment of stereotactic, 3D conformal and intensity-modulated radiotherapy of brain tumors.

    Science.gov (United States)

    Caivano, R; Fiorentino, A; Pedicini, P; Califano, G; Fusco, V

    2014-05-01

    To evaluate radiotherapy treatment planning accuracy by varying computed tomography (CT) slice thickness and tumor size. CT datasets from patients with primary brain disease and metastatic brain disease were selected. Tumor volumes ranging from about 2.5 to 100 cc and CT scan at different slice thicknesses (1, 2, 4, 6 and 10 mm) were used to perform treatment planning (1-, 2-, 4-, 6- and 10-CT, respectively). For any slice thickness, a conformity index (CI) referring to 100, 98, 95 and 90 % isodoses and tumor size was computed. All the CI and volumes obtained were compared to evaluate the impact of CT slice thickness on treatment plans. The smallest volumes reduce significantly if defined on 1-CT with respect to 4- and 6-CT, while the CT slice thickness does not affect target definition for the largest volumes. The mean CI for all the considered isodoses and CT slice thickness shows no statistical differences when 1-CT is compared to 2-CT. Comparing the mean CI of 1- with 4-CT and 1- with 6-CT, statistical differences appear only for the smallest volumes with respect to 100, 98 and 95 % isodoses-the CI for 90 % isodose being not statistically significant for all the considered PTVs. The accuracy of radiotherapy tumor volume definition depends on CT slice thickness. To achieve a better tumor definition and dose coverage, 1- and 2-CT would be suitable for small targets, while 4- and 6-CT are suitable for the other volumes.

  8. Comparison of the developmental potential of 2-week-old preantral follicles derived from vitrified ovarian tissue slices, vitrified whole ovaries and vitrified/transplanted newborn mouse ovaries using the metal surface method

    Directory of Open Access Journals (Sweden)

    Hsu Kung-Hao

    2008-04-01

    Full Text Available Abstract Background Cryopreservation of preantral follicles or ovarian tissues would enable the storage of large numbers of primordial follicles or preantral follicles and preserves the structural integrity of somatic and reproductive cells. In the present study, we compared the developmental potential of cryopreserved two-week-old mouse preantral follicles, ovarian tissue slices, two-week-old mouse ovaries and newborn mouse ovaries using a metal plate with a high cooling rate for cooling the droplet of vitrification solution. Methods Groups of 2 to 4 samples (including of 14-day old preantral follicles, ovarian tissue slices, whole ovaries, and whole newborn ovaries were exposed to 4% ethylene glycol (EG in DPBS + 10% FBS for 15 min and then rinsed in a vitrification solution composed of 6 M ethylene glycol and 0.4 M trehalose in DPBS + 10% FBS. Equilibration in room temperature was performed for 20–30 seconds for preantral follicle and 5 min equilibration was performed in an ice bath for ovaries. The samples were dropped onto the surface of metal plate around -180°C in the volume of 2 μl and 6 μl. After thawing, the ovarian tissue was mechanically isolated for collecting the preantral follicles. The thawed newborn ovaries were transplanted under the renal capsule of recipient male mice for 14 days. Preantral follicles collected from each groups were cultured individually in 20-μl droplets of α-MEM culture medium in culture dish for 12 days. On the day 12 of culture, the cumulus-oocyte complexes (COCs were collected for IVM and IVF. Fertilization and embryo cleavage were scored. Results After the vitrification of 14-day-old preantral follicles using 2 μl or 6 μl droplet onto surface of metal plate, the results indicated that no significant difference in survival rate, antral-like cavity formation, COCs collected, 2 cell embryo cleavage and blastocyst development was found in vitrification of the 2 μl and 6 μl droplet groups. As

  9. Effect of ultrasound and centrifugal force on carambola (Averrhoa carambola L.) slices during osmotic dehydration.

    Science.gov (United States)

    Barman, Nirmali; Badwaik, Laxmikant S

    2017-01-01

    Osmotic dehydration (OD) of carambola slices were carried out using glucose, sucrose, fructose and glycerol as osmotic agents with 70°Bx solute concentration, 50°C of temperature and for time of 180min. Glycerol and sucrose were selected on the basis of their higher water loss, weight reduction and lowers solid gain. Further the optimization of OD of carambola slices (5mm thick) were carried out under different process conditions of temperature (40-60°C), concentration of sucrose and glycerol (50-70°Bx), time (180min) and fruit to solution ratio (1:10) against various responses viz. water loss, solid gain, texture, rehydration ratio and sensory score according to a composite design. The optimized value for temperature, concentration of sucrose and glycerol has been found to be 50°C, 66°Bx and 66°Bx respectively. Under optimized conditions the effect of ultrasound for 10, 20, 30min and centrifugal force (2800rpm) for 15, 30, 45 and 60min on OD of carambola slices were checked. The controlled samples showed 68.14% water loss and 13.05% solid gain in carambola slices. While, the sample having 30min ultrasonic treatment showed 73.76% water loss and 9.79% solid gain; and the sample treated with centrifugal force for 60min showed 75.65% water loss and 6.76% solid gain. The results showed that with increasing in treatment time the water loss, rehydration ratio were increased and solid gain, texture were decreased. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Central Administration of Lipopolysaccharide Induces Depressive-like Behavior in Vivo and Activates Brain Indoleamine 2,3 Dioxygenase In Murine Organotypic Hippocampal Slice Cultures

    Directory of Open Access Journals (Sweden)

    Kavelaars Annemieke

    2010-08-01

    Full Text Available Abstract Background Transient stimulation of the innate immune system by an intraperitoneal injection of lipopolysaccharide (LPS activates peripheral and central expression of the tryptophan degrading enzyme indoleamine 2,3 dioxygenase (IDO which mediates depressive-like behavior. It is unknown whether direct activation of the brain with LPS is sufficient to activate IDO and induce depressive-like behavior. Methods Sickness and depressive-like behavior in C57BL/6J mice were assessed by social exploration and the forced swim test, respectively. Expression of cytokines and IDO mRNA was measured by real-time RT-PCR and cytokine protein was measured by enzyme-linked immunosorbent assays (ELISAs. Enzymatic activity of IDO was estimated as the amount of kynurenine produced from tryptophan as determined by high pressure liquid chromatography (HPLC with electrochemical detection. Results Intracerebroventricular (i.c.v. administration of LPS (100 ng increased steady-state transcripts of TNFα, IL-6 and the inducible isoform of nitric oxide synthase (iNOS in the hippocampus in the absence of any change in IFNγ mRNA. LPS also increased IDO expression and induced depressive-like behavior, as measured by increased duration of immobility in the forced swim test. The regulation of IDO expression was investigated using in situ organotypic hippocampal slice cultures (OHSCs derived from brains of newborn C57BL/6J mice. In accordance with the in vivo data, addition of LPS (10 ng/ml to the medium of OHSCs induced steady-state expression of mRNA transcripts for IDO that peaked at 6 h and translated into increased IDO enzymatic activity within 8 h post-LPS. This activation of IDO by direct application of LPS was preceded by synthesis and secretion of TNFα and IL-6 protein and activation of iNOS while IFNγ expression was undetectable. Conclusion These data establish that activation of the innate immune system in the brain is sufficient to activate IDO and induce

  11. Myocardial slice: a physiological approach to beta-adrenergic ([3H] CGP-12177) receptor binding in hamster and guinea pig heart.

    Science.gov (United States)

    Watson-Wright, W M; Armour, J A; Johnstone, D E; Wilkinson, M

    1989-08-01

    A new technique is described for the characterization and quantification of beta-adrenergic receptors in biologically viable slices of myocardium from the hamster right ventricle using the hydrophilic radioligand, [3H]CGP-12177 (CGP). Binding was stereospecific, saturable, of high affinity, reversible, displaceable by appropriate drugs, and highly positively correlated with increasing tissue concentrations. Bmax for CGP binding to myocardial slices from 50-day-old male Golden Syrian hamsters was 3.28 +/- 0.15 fmol/mg wet weight, while Kd was 0.21 +/- 0.02 nM. Freezing resulted in a close to 50% loss of receptor number with no apparent change in affinity. The slice preparation may be utilized to detect in vivo changes in myocardial cell surface receptors, as evidenced by the fact that the number of receptors in slices from ischemic guinea pigs was increased (Bmax = 15.5 +/- 1.25 fmol/mg wet wt) compared with sham-operated controls (Bmax = 10.4 +/- 0.38 fmol/mg wet wt). The minimal tissue disruption associated with this procedure, as well as its speed, simplicity, and relatively low cost, suggest that the myocardial slice preparation provides an important methodology for the study of beta-adrenergic receptor binding in the semiintact myocardium.

  12. Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model

    Energy Technology Data Exchange (ETDEWEB)

    Um, Ki Doo; Lee, Byung Do [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2004-03-15

    This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works 3.0) and RP model fabrication were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. There were relative error percentage in absolute value of 0.97, 1.98, 3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  13. Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model

    International Nuclear Information System (INIS)

    Um, Ki Doo; Lee, Byung Do

    2004-01-01

    This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works 3.0) and RP model fabrication were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. There were relative error percentage in absolute value of 0.97, 1.98, 3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  14. Accelerating Magnetic Resonance Fingerprinting (MRF) using t-Blipped Simultaneous Multi-Slice (SMS) acquisition

    Science.gov (United States)

    Ye, Huihui; Ma, Dan; Jiang, Yun; Cauley, Stephen F.; Du, Yiping; Wald, Lawrence L.; Griswold, Mark A.; Setsompop, Kawin

    2015-01-01

    Purpose We incorporate Simultaneous Multi-Slice (SMS) acquisition into MR Fingerprinting (MRF) to accelerate the MRF acquisition. Methods The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the signal from different simultaneously excited slices are encoded with different phases without disturbing the signal evolution. Further, by varying the Gz blip area and/or polarity as a function of TR, the slices’ differential phase can also be made to vary as a function of time. For reconstruction of t-Blipped SMS-MRF data, we demonstrate a combined slice-direction SENSE and modified dictionary matching method. Results In Monte Carlo simulation, the parameter mapping from Multi-band factor (MB)=2 t-Blipped SMS-MRF shows good accuracy and precision when compared to results from reference conventional MRF data with concordance correlation coefficients (CCC) of 0.96 for T1 estimates and 0.90 for T2 estimates. For in vivo experiments, T1 and T2 maps from MB=2 t-Blipped SMS-MRF have a high agreement with ones from conventional MRF. Conclusions The MB=2 t-Blipped SMS-MRF acquisition/reconstruction method has been demonstrated and validated to provide more rapid parameter mapping in the MRF framework. PMID:26059430

  15. Bronchoconstriction Induces TGF-β Release and Airway Remodelling in Guinea Pig Lung Slices.

    Directory of Open Access Journals (Sweden)

    Tjitske A Oenema

    Full Text Available Airway remodelling, including smooth muscle remodelling, is a primary cause of airflow limitation in asthma. Recent evidence links bronchoconstriction to airway remodelling in asthma. The mechanisms involved are poorly understood. A possible player is the multifunctional cytokine TGF-β, which plays an important role in airway remodelling. Guinea pig lung slices were used as an in vitro model to investigate mechanisms involved in bronchoconstriction-induced airway remodelling. To address this aim, mechanical effects of bronchoconstricting stimuli on contractile protein expression and TGF-β release were investigated. Lung slices were viable for at least 48 h. Both methacholine and TGF-β1 augmented the expression of contractile proteins (sm-α-actin, sm-myosin, calponin after 48 h. Confocal fluorescence microscopy showed that increased sm-myosin expression was enhanced in the peripheral airways and the central airways. Mechanistic studies demonstrated that methacholine-induced bronchoconstriction mediated the release of biologically active TGF-β, which caused the increased contractile protein expression, as inhibition of actin polymerization (latrunculin A or TGF-β receptor kinase (SB431542 prevented the methacholine effects, whereas other bronchoconstricting agents (histamine and KCl mimicked the effects of methacholine. Collectively, bronchoconstriction promotes the release of TGF-β, which induces airway smooth muscle remodelling. This study shows that lung slices are a useful in vitro model to study mechanisms involved in airway remodelling.

  16. Textural properties of infra red dried apple slices as affected by high ...

    African Journals Online (AJOL)

    treatment on drying rate and textural properties of the infra red dried apple slices. Ultrasound device working at a frequency of 24 kHz with a power capacity of 200 W was used for ultrasound pre-treatment. The amplitudes used for ultrasonic ...

  17. Evaluation of the precision-cut liver and lung slice systems for the study of induction of CYP1, epoxide hydrolase and glutathione S-transferase activities.

    Science.gov (United States)

    Pushparajah, Daphnee S; Umachandran, Meera; Plant, Kathryn E; Plant, Nick; Ioannides, Costas

    2007-02-28

    The principal objective was to ascertain whether precision-cut tissue slices can be used to evaluate the potential of chemicals to induce CYP1, epoxide hydrolase and glutathione S-transferase activities, all being important enzymes involved in the metabolism of polycyclic aromatic hydrocarbons. Precision-cut rat liver and lung slices were incubated with a range of benzo[a]pyrene concentrations for various time periods. A rise in the O-deethylation of ethoxyresorufin was seen in both liver and lung slices exposed to benzo[a]pyrene, which was accompanied by increased CYP1A apoprotein levels. Pulmonary CYP1B1 apoprotein levels and hepatic mRNA levels were similarly enhanced. Elevated epoxide hydrolase and glutathione S-transferase activities were also observed in liver slices following incubation for 24h; similarly, a rise in apoprotein levels of both enzymes was evident, peak levels occurring at the same time point. When mRNA levels were monitored, a rise in the levels of both enzymes was seen as early as 4h after incubation, but maximum levels were attained at 24 h. In lung slices, induction of epoxide hydrolase by benzo[a]pyrene was observed after a 24-h incubation, and at a concentration of 1 microM; a rise in apoprotein levels was seen at this time point. Glutathione S-transferase activity was not inducible in lung slices by benzo[a]pyrene but a modest increase was observed in hepatic slices. Collectively, these studies confirmed CYP1A induction in rat liver slices and established that CYP1B1 expression, and epoxide hydrolase and glutathione S-transferase activities are inducible in precision-cut tissue slices.

  18. Atorvastatin and Fluoxetine Prevent Oxidative Stress and Mitochondrial Dysfunction Evoked by Glutamate Toxicity in Hippocampal Slices.

    Science.gov (United States)

    Ludka, Fabiana K; Dal-Cim, Tharine; Binder, Luisa Bandeira; Constantino, Leandra Celso; Massari, Caio; Tasca, Carla I

    2017-07-01

    Atorvastatin has been shown to exert a neuroprotective action by counteracting glutamatergic toxicity. Recently, we have shown atorvastatin also exerts an antidepressant-like effect that depends on both glutamatergic and serotonergic systems modulation. Excitotoxicity is involved in several brain disorders including depression; thus, it is suggested that antidepressants may target glutamatergic system as a final common pathway. In this study, a comparison of the mechanisms involved in the putative neuroprotective effect of a repetitive atorvastatin or fluoxetine treatment against glutamate toxicity in hippocampal slices was performed. Adult Swiss mice were treated with atorvastatin (10 mg/kg, p.o.) or fluoxetine (10 mg/kg, p.o.), once a day during seven consecutive days. On the eighth day, animals were killed and hippocampal slices were obtained and subjected to an in vitro protocol of glutamate toxicity. An acute treatment of atorvastatin or fluoxetine was not neuroprotective; however, the repeated atorvastatin or fluoxetine treatment prevented the decrease in cellular viability induced by glutamate in hippocampal slices. The loss of cellular viability induced by glutamate was accompanied by increased D-aspartate release, increased reactive oxygen species (ROS) and nitric oxide (NO) production, and impaired mitochondrial membrane potential. Atorvastatin or fluoxetine repeated treatment also presented an antidepressant-like effect in the tail suspension test. Atorvastatin or fluoxetine treatment was effective in protecting mice hippocampal slices from glutamate toxicity by preventing the oxidative stress and mitochondrial dysfunction.

  19. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    Energy Technology Data Exchange (ETDEWEB)

    Favazza, C; Yu, L; Leng, S; McCollough, C [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  20. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    International Nuclear Information System (INIS)

    Favazza, C; Yu, L; Leng, S; McCollough, C

    2015-01-01

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  1. Automated Slicing for a Multi-Axis Metal Deposition System (Preprint)

    Science.gov (United States)

    2006-09-01

    experimented with different materials like H13 tool steel to build the part. Following the same slicing and scanning toolpath result, there is a geometric...and analysis tool -centroidal axis. Similar to medial axis, it contains geometry and topological information but is significantly computationally...geometry reasoning and analysis tool -centroidal axis. Similar to medial axis, it contains geometry and topological information but is significantly

  2. Assessment of long-term cultivated human precision-cut lung slices as an ex vivo system for evaluation of chronic cytotoxicity and functionality.

    Science.gov (United States)

    Neuhaus, Vanessa; Schaudien, Dirk; Golovina, Tatiana; Temann, Ulla-Angela; Thompson, Carolann; Lippmann, Torsten; Bersch, Claus; Pfennig, Olaf; Jonigk, Danny; Braubach, Peter; Fieguth, Hans-Gerd; Warnecke, Gregor; Yusibov, Vidadi; Sewald, Katherina; Braun, Armin

    2017-01-01

    Investigation of basic chronic inflammatory mechanisms and development of new therapeutics targeting the respiratory tract requires appropriate testing systems, including those to monitor long- persistence. Human precision-cut lung slices (PCLS) have been demonstrated to mimic the human respiratory tract and have potential of an alternative, ex-vivo system to replace or augment in-vitro testing and animal models. So far, most research on PCLS has been conducted for short cultivation periods (≤72 h), while analyses of slowly metabolized therapeutics require long-term survival of PCLS in culture. In the present study, we evaluated viability, physiology and structural integrity of PCLS cultured for up to 15 days. PCLS were cultured for 15 days and various parameters were assessed at different time points. Structural integrity and viability of cultured PCLS remained constant for 15 days. Moreover, bronchoconstriction was inducible over the whole period of cultivation, though with decreased sensitivity (EC 50 1d = 4 × 10 -8  M vs. EC 50 15d = 4 × 10 -6  M) and reduced maximum of initial airway area (1d = 0.5% vs. 15d = 18.7%). In contrast, even though still clearly inducible compared to medium control, LPS-induced TNF-α secretion decreased significantly from day 1 to day 15 of culture. Overall, though long-term cultivation of PCLS need further investigation for cytokine secretion, possibly on a cellular level, PCLS are feasible for bronchoconstriction studies and toxicity assays.

  3. Mucuna pruriens seed extract reduces oxidative stress in nigrostriatal tissue and improves neurobehavioral activity in paraquat-induced Parkinsonian mouse model.

    Science.gov (United States)

    Yadav, Satyndra Kumar; Prakash, Jay; Chouhan, Shikha; Singh, Surya Pratap

    2013-06-01

    Parkinson's disease (PD) is a neurodegenerative disease which causes rigidity, resting tremor and postural instability. Treatment for this disease is still under investigation. Mucuna pruriens (L.), is a traditional herbal medicine, used in India since 1500 B.C., as a neuroprotective agent. In this present study, we evaluated the therapeutic effects of aqueous extract of M. pruriens (Mp) seed in Parkinsonian mouse model developed by chronic exposure to paraquat (PQ). Results of our study revealed that the nigrostriatal portion of Parkinsonian mouse brain showed significantly increased levels of nitrite, malondialdehyde (MDA) and reduced levels of catalase compared to the control. In the Parkinsonian mice hanging time was decreased, whereas narrow beam walk time and foot printing errors were increased. Treatment with aqueous seed extract of Mp significantly increased the catalase activity and decreased the MDA and nitrite level, compared to untreated Parkinsonian mouse brain. Mp treatment also improved the behavioral abnormalities. It increased hanging time, whereas it decreased narrow beam walk time and foot printing error compared to untreated Parkinsonian mouse brain. Furthermore, we observed a significant reduction in tyrosine hydroxylase (TH) immunoreactivity in the substantia nigra (SN) and striatum region of the brain, after treatment with PQ which was considerably restored by the use of Mp seed extract. Our result suggested that Mp seed extract treatment significantly reduced the PQ induced neurotoxicity as evident by decrease in oxidative damage, physiological abnormalities and immunohistochemical changes in the Parkinsonian mouse. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Mechanisms contributing to cluster formation in the inferior olivary nucleus in brainstem slices from postnatal mice

    DEFF Research Database (Denmark)

    Kølvraa, Mathias; Müller, Felix C; Jahnsen, Henrik

    2014-01-01

    The inferior olivary nucleus (IO) in in vitro slices from postnatal mice (P5.5-P15.5) spontaneously generates clusters of neurons with synchronous calcium transients, and intracellular recordings from IO neurons suggest that electrical coupling between neighbouring IO neurons may serve as a synch......The inferior olivary nucleus (IO) in in vitro slices from postnatal mice (P5.5-P15.5) spontaneously generates clusters of neurons with synchronous calcium transients, and intracellular recordings from IO neurons suggest that electrical coupling between neighbouring IO neurons may serve...

  5. Different contrast injection protocols for 64-slice spiral CT coronary angiography

    International Nuclear Information System (INIS)

    Lu Jinguo; Lv Bing; Bai Hua; Tang Xiang; Yang Xinling; Jiang Shiliang; Dai Ruiping; Qiu Jinhai; Chen Tao

    2008-01-01

    Objective: To determine the optimal contrast protocols for 64-slice spiral CT coronary angiography in order to reduce the volume of contrast injection. Methods: One hundred fifty patients scheduled to undergo 64-slice spiral CT coronary angiography were prospectively randomized into the following five groups with different injection protocols: group 1: uniphasic injection without a flush; group 2: biphasic injection with a flush; group 3, group 4 and group 5 : triphasic injection with a diluted contrast material with 3:7, 5:5, 7:3 contrast/saline ratio respectively. Attenuation was measured in the right atrium, right ventricle, left atrium, left ventricle, ascending aorta, right coronary artery and left coronary artery and analyzed with single factor variance test (ANOVA). The quality of the coronary artery images was evaluated and compared using person Chi-Square. Results: The total contrast material volume were (67.0±5.3) ml, (59.9±4.9) ml, (62.9±3.2) ml, (69.2±5.7) ml and (70.9±4.6) ml in five groups respectively (F=27.43, P 2 =18.81, P 2 =31.44, P<0.01). The artifacts in the superior vena cava in group 1 was the most, and in group 2 was the least. The mean enhancement values of right and left coronary arteries in group 2 were significantly greater than those in other groups (F=2.47 and 4.10, P<0.05). The visualization of both left ventricle and right ventricle cavities was the best in group 3. Conclusion: Biphasic injection and triphasic injection are better than uniphasic injection for 64-slice spiral CT coronary angiography and triphasic injection is better than biphasic injection for the visualization of both left ventricle and right ventricle cavities. (authors)

  6. Impact of 64-slice coronary CT on the management of patients presenting with acute chest pain: results of a prospective two-centre study

    Energy Technology Data Exchange (ETDEWEB)

    Christiaens, Luc [Departement d' imagerie Cardiovasculaire, Assistance Publique- Hopitaux de Paris, Hopital Lariboisiere, Paris (France); CHU de Poitiers, Departement de Cardiologie, Poitiers (France); Duchat, Florent; Boudiaf, Mourad; Fargeaudou, Yann; Ledref, Olivier; Soyer, Philippe [Departement d' imagerie Cardiovasculaire, Assistance Publique- Hopitaux de Paris, Hopital Lariboisiere, Paris (France); Tasu, Jean-Pierre [CHU de Poitiers, Departement de Radiologie, Poitiers (France); Sirol, Marc [Departement d' imagerie Cardiovasculaire, Assistance Publique- Hopitaux de Paris, Hopital Lariboisiere, Paris (France); INSERM UFR U942, Insuffisance Cardiaque et Biomarqueurs, Universite Paris 7 - Denis Diderot, Hopital Lariboisiere, Paris (France); Universite Paris VII - Denis Diderot, Assistance Publique - Hopitaux de Paris, Service de Radiologie Vasculaire, Hopital Lariboisiere, Paris (France)

    2012-05-15

    Our two-centre prospective study evaluates the usefulness of 64-slice coronary computed tomography (CCT) to rule out significant coronary artery stenosis in patients admitted in emergency departments (ED) for acute coronary syndromes (ACS) with low-to-intermediate risk score. Patients (175) admitted for acute chest pain (ACP), unmodified electrocardiogram and first troponin measurement within normal ranges were included. A second troponin measurement and a 64-slice CCT within 24 h were performed. Major adverse cardiac events (MACE) were recorded during follow-up (6 months {+-} 2). 64-slice CCT was either normal or showed non-significant coronary stenosis in the majority of patients (78%). 64-slice CCT depicted significant stenosis (>50% diameter) in 22% of patient whereas initial clinical and biological evaluation was reassuring. For negative CCTs, elevated troponin at second measurement did not modify the strategy or treatment of patients. No MACEs were noted during follow up. In 12% of patients CCT identified unsuspected non-coronary abnormalities. Our study confirms 64-slice CCT utility to rule out significant coronary artery stenosis in 8/10 patients admitted in ED with ACP or ACS with low-to-intermediate risk score. Early discharge with a negative 64-slice CCT is associated with very low risk of cardiac events at 6 months. (orig.)

  7. Differences in kainate receptor involvement in hippocampal mossy fibre long-term potentiation depending on slice orientation.

    Science.gov (United States)

    Sherwood, John L; Amici, Mascia; Dargan, Sheila L; Culley, Georgia R; Fitzjohn, Stephen M; Jane, David E; Collingridge, Graham L; Lodge, David; Bortolotto, Zuner A

    2012-09-01

    Long-term potentiation (LTP) is a well-established experimental model used to investigate the synaptic basis of learning and memory. LTP at mossy fibre - CA3 synapses in the hippocampus is unusual because it is normally N-methyl-d-aspartate (NMDA) receptor-independent. Instead it seems that the trigger for mossy fibre LTP involves kainate receptors (KARs). Although it is generally accepted that pre-synaptic KARs play an essential role in frequency facilitation and LTP, their subunit composition remains a matter of significant controversy. We have reported previously that both frequency facilitation and LTP can be blocked by selective antagonism of GluK1 (formerly GluR5/Glu(K5))-containing KARs, but other groups have failed to reproduce this effect. Moreover, data from receptor knockout and mRNA expression studies argue against a major role of GluK1, supporting a more central role for GluK2 (formerly GluR6/Glu(K6)). A potential reason underlying the controversy in the pharmacological experiments may reside in differences in the preparations used. Here we show differences in pharmacological sensitivity of synaptic plasticity at mossy fibre - CA3 synapses depend critically on slice orientation. In transverse slices, LTP of fEPSPs was invariably resistant to GluK1-selective antagonists whereas in parasagittal slices LTP was consistently blocked by GluK1-selective antagonists. In addition, there were pronounced differences in the magnitude of frequency facilitation and the sensitivity to the mGlu2/3 receptor agonist DCG-IV. Using anterograde labelling of granule cells we show that slices of both orientations possess intact mossy fibres and both large and small presynaptic boutons. Transverse slices have denser fibre tracts but a smaller proportion of giant mossy fibre boutons. These results further demonstrate a considerable heterogeneity in the functional properties of the mossy fibre projection. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. The cause of the artifact in 4-slice helical computed tomography

    International Nuclear Information System (INIS)

    Taguchi, Katsuyuki; Aradate, Hiroshi; Saito, Yasuo; Zmora, Ilan; Han, Kyung S.; Silver, Michael D.

    2004-01-01

    The causes of the image artifacts in a 4-slice helical computed tomography have been discussed as follows: (1) changeover in pairs of data used in z interpolation, (2) sampling interval in z, and (3) the cone angle. This study analyzes the first two causes of the artifact and describes how the current algorithm [K. Taguchi and H. Aradate, Radiology 205P, 390 (1997); 205P, 618 (1997); Med. Phys. 25, 550-561 (1998); H. Hu, ibid. 26, 5-18 (1999); S. Schaller et al., IEEE Trans. Med. Imaging 19, 822-834 (2000); K. Taguchi, Ph.D. thesis, University of Tsukuba, 2002] solves the problem. An interpolated sinogram for a slice at the edge of a ball phantom shows discontinuity caused by the changeover. If we extend the streak artifact in the reconstructed image, it crosses the focus orbit at the corresponding projection angle. Applying z filtering can reduce such causes by its feathering effect and mixing data obtained by different cone angles; the best results are provided when z filtering is applied to densely sampled helical data

  9. Fine Slicing of the Value Chain and Offshoring of Essential Activities

    DEFF Research Database (Denmark)

    Linares-Navarro, Esmeralda; Pedersen, Torben; Pla-Barber, José

    2014-01-01

    The offshoring of more advanced activities is increasing and a debate about the limits of offshoring has emerged. Companies are fine-slicing their value chains, and moving beyond the offshoring of peripheral and non-core activities to the offshoring of advanced and essential activities that are c......The offshoring of more advanced activities is increasing and a debate about the limits of offshoring has emerged. Companies are fine-slicing their value chains, and moving beyond the offshoring of peripheral and non-core activities to the offshoring of advanced and essential activities...... that companies are redefining their core activities and in this process, some essential activities previously viewed as core activities are being detached from the core, and they become more offshorable. The study uses a sample of 565 offshoring operations conducted by 263 multinational companies from 15...... European countries. A logistic regression was used to analyze the relationship between the activities offshored (non-core versus essential activities) and the offshoring mode implemented (captive offshoring versus offshore outsourcing). We find that essential activities are typically offshored using...

  10. [Simulation and data analysis of stereological modeling based on virtual slices].

    Science.gov (United States)

    Wang, Hao; Shen, Hong; Bai, Xiao-yan

    2008-05-01

    To establish a computer-assisted stereological model for simulating the process of slice section and evaluate the relationship between section surface and estimated three-dimensional structure. The model was designed by mathematic method as a win32 software based on the MFC using Microsoft visual studio as IDE for simulating the infinite process of sections and analysis of the data derived from the model. The linearity of the fitting of the model was evaluated by comparison with the traditional formula. The win32 software based on this algorithm allowed random sectioning of the particles distributed randomly in an ideal virtual cube. The stereological parameters showed very high throughput (>94.5% and 92%) in homogeneity and independence tests. The data of density, shape and size of the section were tested to conform to normal distribution. The output of the model and that from the image analysis system showed statistical correlation and consistency. The algorithm we described can be used for evaluating the stereologic parameters of the structure of tissue slices.

  11. Absence of synaptic regulation by phosducin in retinal slices.

    Directory of Open Access Journals (Sweden)

    James H Long

    Full Text Available Phosducin is an abundant photoreceptor protein that binds G-protein βγ subunits and plays a role in modulating synaptic transmission at photoreceptor synapses under both dark-adapted and light-adapted conditions in vivo. To examine the role of phosducin at the rod-to-rod bipolar cell (RBC synapse, we used whole-cell voltage clamp recordings to measure the light-evoked currents from both wild-type (WT and phosducin knockout (Pd(-/- RBCs, in dark- and light-adapted retinal slices. Pd(-/- RBCs showed smaller dim flash responses and steeper intensity-response relationships than WT RBCs, consistent with the smaller rod responses being selectively filtered out by the non-linear threshold at the rod-to-rod bipolar synapse. In addition, Pd(-/- RBCs showed a marked delay in the onset of the light-evoked currents, similar to that of a WT response to an effectively dimmer flash. Comparison of the changes in flash sensitivity in the presence of steady adapting light revealed that Pd(-/- RBCs desensitized less than WT RBCs to the same intensity. These results are quantitatively consistent with the smaller single photon responses of Pd(-/- rods, owing to the known reduction in rod G-protein expression levels in this line. The absence of an additional synaptic phenotype in these experiments suggests that the function of phosducin at the photoreceptor synapse is abolished by the conditions of retinal slice recordings.

  12. Evaluation of TSE- and T1-3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT

    International Nuclear Information System (INIS)

    Stork, A.; Schulze, D.; Koops, A.; Kemper, J.; Adam, G.

    2002-01-01

    Purpose: Evaluation of TSE- and T 1 -3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT. Materials and methods: Forty artificial cartilage lesions in ten bovine patellae were immersed in a solution of iodinated contrast medium and assessed with ultrahigh resolution multi-slice CT. Fat-suppressed TSE images with intermediate- and T 2 -weighting at a slice thickness of 2, 3 and 4 mm as well as fat-suppressed T 1 -weighted 3D-FLASH images with an effective slice thickness of 1, 2 and 3 mm were acquired at 1.5 T. After adding Gd-DTPA to the saline solution containing the patellae, the T 1 -weighted 3D-FLASH imaging was repeated. Results: All cartilage lesions were visualised and graded with ultrahigh resolution multi-slice CT. The TSE images had a higher sensitivity and a higher inter- and intraobserver kappa compared to the FLASH-sequences (TSE: 70-95%; 0.82-0.83; 0.85-0.9; FLASH: 57.5-85%; 0.53-0.72; 0.73-0.82, respectively). An increase in slice thickness decreased the sensitivity, whereby deep lesions were even reliably depicted on TSE images at a slice thickness of 3 and 4 mm. Adding Gd-DTPA to the saline solution increased the sensitivity by 10% with no detectable advantage over the T 2 -weighted TSE images. Conclusion: TSE sequences and application of Gd-DTPA seemed to be superior to T 1 -weighted 3D-FLASH sequences without Gd-DTPA in the detection of focal cartilage lesions. The ultrahigh resolution multi-slice CT can serve as in vitro reference standard for focal cartilage lesions. (orig.) [de

  13. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M. Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 ± 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and κ-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (κ = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT

  14. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Annuar, Bin Rapaee [Faculty of Medicine, University Malaysia Sarawak (Malaysia); Department of Cardiology, Sarawak General Hospital (Malaysia)], E-mail: rannuar@fmhs.unimas.my; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam [Department of Cardiology, Sarawak General Hospital (Malaysia); Seyfarth, M. Tobias [Sieman Medical Solution (Germany); Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat [Department of Cardiology, Sarawak General Hospital (Malaysia); Lin, Naing [Universiti Sains Malaysia (Malaysia); Liew, Houng Bang; Sim, Kui Hian [Department of Cardiology, Sarawak General Hospital (Malaysia)

    2008-01-15

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 {+-} 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and {kappa}-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement ({kappa} = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  15. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: a comparison with cardiac magnetic resonance.

    Science.gov (United States)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Thirty-two consecutive patients (mean age, 56.5+/-9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and kappa-statistics. The 64-slice MSCT agreed well with CMR for assessment of LVEF (r=0.92; p<0.0001), LVdV (r=0.98; p<0.0001) and LVsV (r=0.98; p<0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r=0.84; p<0.0001), LVdV (r=0.83; p<0.0001) and LVsV (r=0.80; p<0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (kappa=0.89 versus 0.63) with CMR. 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  16. Exploring the Effects of Pulsed Electric Field Processing Parameters on Polyacetylene Extraction from Carrot Slices

    Directory of Open Access Journals (Sweden)

    Ingrid Aguiló-Aguayo

    2015-03-01

    Full Text Available The effects of various pulsed electric field (PEF parameters on the extraction of polyacetylenes from carrot slices were investigated. Optimised conditions with regard to electric field strength (1–4 kV/cm, number of pulses (100–1500, pulse frequency (10–200 Hz and pulse width (10–30 μs were identified using response surface methodology (RSM to maximise the extraction of falcarinol (FaOH, falcarindiol (FaDOH and falcarindiol-3-acetate (FaDOAc from carrot slices. Data obtained from RSM and experiments fitted significantly (p < 0.0001 the proposed second-order response functions with high regression coefficients (R2 ranging from 0.82 to 0.75. Maximal FaOH (188%, FaDOH (164.9% and FaDOAc (166.8% levels relative to untreated samples were obtained from carrot slices after applying PEF treatments at 4 kV/cm with 100 number of pulses of 10 μs at 10 Hz. The predicted values from the developed quadratic polynomial equation were in close agreement with the actual experimental values with low average mean deviations (E% ranging from 0.68% to 3.58%.

  17. Ultrastructure of sheep primordial follicles cultured in the presence of indol acetic acid, EGF, and FSH

    DEFF Research Database (Denmark)

    Andrade, Evelyn Rabelo; Hyttel, Poul; Landim-Alvarenga, Fernanda Da Cruz

    2011-01-01

    The aim of this study was to investigate the ultrastructural characteristics of primordial follicles after culturing of sheep ovarian cortical slices in the presence of indol acetic acid (IAA), Epidermal Growth Factor (EGF), and FSH. To evaluate ultrastructure of primordial follicles cultured...... in MEM (control) or in MEM containing IAA, EGF, and FSH, fragments of cultured tissue were processes for transmission electron microscopy. Except in the control, primordial follicles cultured in supplemented media for 6¿d were ultrastructurally normal. They had oocyte with intact nucleus...... and the cytoplasm contained heterogeneous-sized lipid droplets and numerous round or elongated mitochondria with intact parallel cristae were observed. Rough endoplasmic reticulum (RER) was rarely found. The granulosa cells cytoplasm contained a great number of mitochondria and abundant RER. In conclusion...

  18. The content of active constituents of stored sliced and powdered preparations of turmeric rhizomes and zedoary (bulb and finger rhizomes

    Directory of Open Access Journals (Sweden)

    Sanan Subhadhirasakul

    2007-11-01

    Full Text Available The stability of active constituents (curcuminoids and volatile oil in turmeric (Curcuma longa Linn. rhizomes and zedoary [Curcuma zedoaria (Berg. Roscoe] bulb and finger rhizomes during storage have been investigated. They were prepared as sliced and powdered and separately packed, either in black polyethylene bags or in paper bags, and stored at room temperature (28-31oC. Samples at initial and three monthly intervals were examined over 12-15 months storage to determine the contents of curcuminoids, volatile oil and moisture. The results showed that storage of rhizomes in black polyethylene bags could prevent samples from taking up moisture better than those stored in paper bags. The sliced and powderedturmeric rhizomes exhibited no decrease in curcuminoids content after 15 months of storage irrespective of the nature of the packing material. However, the slices of zedoary (bulb and finger rhizomes lost curcuminoids to a lesser extent than powdered rhizomes during storage period. Volatile oil content of turmeric rhizomes, zedoary (bulb and finger rhizomes decreased slower when stored as slices rather than as powders. The result from the present study suggested that in order to maintain the quality of turmeric and zedoary rhizomes as raw material for food and medicinal uses, they should be prepared in sliced form and stored in black polyethylene bags in order to maintain their content of active constituents during storage period.

  19. Over a century of neuron culture: from the hanging drop to microfluidic devices.

    Science.gov (United States)

    Millet, Larry J; Gillette, Martha U

    2012-12-01

    The brain is the most intricate, energetically active, and plastic organ in the body. These features extend to its cellular elements, the neurons and glia. Understanding neurons, or nerve cells, at the cellular and molecular levels is the cornerstone of modern neuroscience. The complexities of neuron structure and function require unusual methods of culture to determine how aberrations in or between cells give rise to brain dysfunction and disease. Here we review the methods that have emerged over the past century for culturing neurons in vitro, from the landmark finding by Harrison (1910) - that neurons can be cultured outside the body - to studies utilizing culture vessels, micro-islands, Campenot and brain slice chambers, and microfluidic technologies. We conclude with future prospects for neuronal culture and considerations for advancement. We anticipate that continued innovation in culture methods will enhance design capabilities for temporal control of media and reagents (chemotemporal control) within sub-cellular environments of three-dimensional fluidic spaces (microfluidic devices) and materials (e.g., hydrogels). They will enable new insights into the complexities of neuronal development and pathology.

  20. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    International Nuclear Information System (INIS)

    Tanaka, Hiroshi

    1988-01-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development. (author)