WorldWideScience

Sample records for newyork times united

  1. Unit-time scheduling problems with time dependent resources

    NARCIS (Netherlands)

    Tautenhahn, T.; Woeginger, G.

    1997-01-01

    We investigate the computational complexity of scheduling problems, where the operations consume certain amounts of renewable resources which are available in time-dependent quantities. In particular, we consider unit-time open shop problems and unit-time scheduling problems with identical parallel

  2. Multiperiod Maximum Loss is time unit invariant.

    Science.gov (United States)

    Kovacevic, Raimund M; Breuer, Thomas

    2016-01-01

    Time unit invariance is introduced as an additional requirement for multiperiod risk measures: for a constant portfolio under an i.i.d. risk factor process, the multiperiod risk should equal the one period risk of the aggregated loss, for an appropriate choice of parameters and independent of the portfolio and its distribution. Multiperiod Maximum Loss over a sequence of Kullback-Leibler balls is time unit invariant. This is also the case for the entropic risk measure. On the other hand, multiperiod Value at Risk and multiperiod Expected Shortfall are not time unit invariant.

  3. Time recording unit for a neutron time of flight spectrometer

    International Nuclear Information System (INIS)

    Puranik, Praful; Ajit Kiran, S.; Chandak, R.M.; Poudel, S.K.; Mukhopadhyay, R.

    2011-01-01

    Here the architecture and design of Time Recording Unit for a Neutron Time of Flight Spectrometer have been described. The Spectrometer would have an array of 50 Nos. of one meter long linear Position Sensitive Detector (PSD) placed vertically around the sample at a distance of 2000 mm. The sample receives periodic pulsed neutron beam coming through a Fermi chopper. The time and zone of detection of a scattered neutron in a PSD gives information of its flight time and path length, which will be used to calculate its energy. A neutron event zone (position) and time detection module for each PSD provides a 2 bit position/zone code and an event timing pulse. The path length assigned to a neutron detected in a zone (Z1, Z2 etc) in the PSD is the mean path length seen by the neutrons detected in that zone of the PSD. A Time recording unit described here receives event zone code and timing pulse for all the 50 detectors, tags a proper time window code to it, before streaming it to computer for calculation of the energy distribution of neutrons scattered from the sample

  4. Discovering the impact of preceding units' characteristics on the wait time of cardiac surgery unit from statistic data.

    Directory of Open Access Journals (Sweden)

    Jiming Liu

    Full Text Available INTRODUCTION: Prior research shows that clinical demand and supplier capacity significantly affect the throughput and the wait time within an isolated unit. However, it is doubtful whether characteristics (i.e., demand, capacity, throughput, and wait time of one unit would affect the wait time of subsequent units on the patient flow process. Focusing on cardiac care, this paper aims to examine the impact of characteristics of the catheterization unit (CU on the wait time of cardiac surgery unit (SU. METHODS: This study integrates published data from several sources on characteristics of the CU and SU units in 11 hospitals in Ontario, Canada between 2005 and 2008. It proposes a two-layer wait time model (with each layer representing one unit to examine the impact of CU's characteristics on the wait time of SU and test the hypotheses using the Partial Least Squares-based Structural Equation Modeling analysis tool. RESULTS: Results show that: (i wait time of CU has a direct positive impact on wait time of SU (β = 0.330, p < 0.01; (ii capacity of CU has a direct positive impact on demand of SU (β = 0.644, p < 0.01; (iii within each unit, there exist significant relationships among different characteristics (except for the effect of throughput on wait time in SU. CONCLUSION: Characteristics of CU have direct and indirect impacts on wait time of SU. Specifically, demand and wait time of preceding unit are good predictors for wait time of subsequent units. This suggests that considering such cross-unit effects is necessary when alleviating wait time in a health care system. Further, different patient risk profiles may affect wait time in different ways (e.g., positive or negative effects within SU. This implies that the wait time management should carefully consider the relationship between priority triage and risk stratification, especially for cardiac surgery.

  5. Discovering the impact of preceding units' characteristics on the wait time of cardiac surgery unit from statistic data.

    Science.gov (United States)

    Liu, Jiming; Tao, Li; Xiao, Bo

    2011-01-01

    Prior research shows that clinical demand and supplier capacity significantly affect the throughput and the wait time within an isolated unit. However, it is doubtful whether characteristics (i.e., demand, capacity, throughput, and wait time) of one unit would affect the wait time of subsequent units on the patient flow process. Focusing on cardiac care, this paper aims to examine the impact of characteristics of the catheterization unit (CU) on the wait time of cardiac surgery unit (SU). This study integrates published data from several sources on characteristics of the CU and SU units in 11 hospitals in Ontario, Canada between 2005 and 2008. It proposes a two-layer wait time model (with each layer representing one unit) to examine the impact of CU's characteristics on the wait time of SU and test the hypotheses using the Partial Least Squares-based Structural Equation Modeling analysis tool. Results show that: (i) wait time of CU has a direct positive impact on wait time of SU (β = 0.330, p relationships among different characteristics (except for the effect of throughput on wait time in SU). Characteristics of CU have direct and indirect impacts on wait time of SU. Specifically, demand and wait time of preceding unit are good predictors for wait time of subsequent units. This suggests that considering such cross-unit effects is necessary when alleviating wait time in a health care system. Further, different patient risk profiles may affect wait time in different ways (e.g., positive or negative effects) within SU. This implies that the wait time management should carefully consider the relationship between priority triage and risk stratification, especially for cardiac surgery.

  6. Centre-containing spiral-geometric structure of the space-time and nonrelativistic relativity of the unit time

    International Nuclear Information System (INIS)

    Shakhazizyan, S.R.

    1987-01-01

    The problem of nonrelativistic dependence of unit length and unit time on the position in the space is considered on the basis of centre-containing spiral-geometric structure of the space-time. The experimental results of variation of the unit time are analyzed which well agree with the requirements of the model proposed. 13 refs.; 12 figs

  7. Discrete Events as Units of Perceived Time

    Science.gov (United States)

    Liverence, Brandon M.; Scholl, Brian J.

    2012-01-01

    In visual images, we perceive both space (as a continuous visual medium) and objects (that inhabit space). Similarly, in dynamic visual experience, we perceive both continuous time and discrete events. What is the relationship between these units of experience? The most intuitive answer may be similar to the spatial case: time is perceived as an…

  8. Application of total care time and payment per unit time model for physician reimbursement for common general surgery operations.

    Science.gov (United States)

    Chatterjee, Abhishek; Holubar, Stefan D; Figy, Sean; Chen, Lilian; Montagne, Shirley A; Rosen, Joseph M; Desimone, Joseph P

    2012-06-01

    The relative value unit system relies on subjective measures of physician input in the care of patients. A payment per unit time model incorporates surgeon reimbursement to the total care time spent in the operating room, postoperative in-house, and clinic time to define payment per unit time. We aimed to compare common general surgery operations by using the total care time and payment per unit time method in order to demonstrate a more objective measurement for physician reimbursement. Average total physician payment per case was obtained for 5 outpatient operations and 4 inpatient operations in general surgery. Total care time was defined as the sum of operative time, 30 minutes per hospital day, and 30 minutes per office visit for each operation. Payment per unit time was calculated by dividing the physician reimbursement per case by the total care time. Total care time, physician payment per case, and payment per unit time for each type of operation demonstrated that an average payment per time spent for inpatient operations was $455.73 and slightly more at $467.51 for outpatient operations. Partial colectomy with primary anastomosis had the longest total care time (8.98 hours) and the least payment per unit time ($188.52). Laparoscopic gastric bypass had the highest payment per time ($707.30). The total care time and payment per unit time method can be used as an adjunct to compare reimbursement among different operations on an institutional level as well as on a national level. Although many operations have similar payment trends based on time spent by the surgeon, payment differences using this methodology are seen and may be in need of further review. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Kozloduy NPP units 3 and 4 rest life time program execution

    International Nuclear Information System (INIS)

    Genov, S.

    2005-01-01

    In this paper the following tasks are considered: Kozloduy NPP units 3 and 4 life time evaluation; programme for the units life time assuring; units 3 and 4 renewals. The main activities for the programme implementation are described and the obtained results are presented. In conclusion, the executed activities of program for assuring the life time of units 3 and 4 of Kozloduy NPP, cogently prove that the lifetime of structures, systems and components, is assured duly and those structures, systems and components will be in service safely, economically effectively and mostly reliable till the end of the 30 years design lifetime. For some of them it has been proved even for 35 and 40 years. Program activities continue during 2005, although the early shutdown of units 3 and 4 is possible

  10. “Josef Albers en Amérique, Peintures sur papier”

    Directory of Open Access Journals (Sweden)

    Jennifer Donelly

    2012-04-01

    Full Text Available Josef Albers, Color study for homage to the square, platinium, not dated, 29,5 X 29,6 cm © 2011 The Josef and Anni foundation / Artists rights society, New-York / Bild-Kunst, Germany. Rights reserved.“Josef Albers en Amérique”, which ran at the Centre Pompidou from February to April 2012, focused on the artist’s work following his 1933 emigration to the United States, where he lived until his death in 1976. Albers was 45 years old when he left Germany and had logged thirteen years at the Bauh...

  11. Efficiency of performing pulmonary procedures in a shared endoscopy unit: procedure time, turnaround time, delays, and procedure waiting time.

    Science.gov (United States)

    Verma, Akash; Lee, Mui Yok; Wang, Chunhong; Hussein, Nurmalah B M; Selvi, Kalai; Tee, Augustine

    2014-04-01

    The purpose of this study was to assess the efficiency of performing pulmonary procedures in the endoscopy unit in a large teaching hospital. A prospective study from May 20 to July 19, 2013, was designed. The main outcome measures were procedure delays and their reasons, duration of procedural steps starting from patient's arrival to endoscopy unit, turnaround time, total case durations, and procedure wait time. A total of 65 procedures were observed. The most common procedure was BAL (61%) followed by TBLB (31%). Overall procedures for 35 (53.8%) of 65 patients were delayed by ≥ 30 minutes, 21/35 (60%) because of "spillover" of the gastrointestinal and surgical cases into the time block of pulmonary procedure. Time elapsed between end of pulmonary procedure and start of the next procedure was ≥ 30 minutes in 8/51 (16%) of cases. In 18/51 (35%) patients there was no next case in the room after completion of the pulmonary procedure. The average idle time of the room after the end of pulmonary procedure and start of next case or end of shift at 5:00 PM if no next case was 58 ± 53 minutes. In 17/51 (33%) patients the room's idle time was >60 minutes. A total of 52.3% of patients had the wait time >2 days and 11% had it ≥ 6 days, reason in 15/21 (71%) being unavailability of the slot. Most pulmonary procedures were delayed due to spillover of the gastrointestinal and surgical cases into the block time allocated to pulmonary procedures. The most common reason for difficulty encountered in scheduling the pulmonary procedure was slot unavailability. This caused increased procedure waiting time. The strategies to reduce procedure delays and turnaround times, along with improved scheduling methods, may have a favorable impact on the volume of procedures performed in the unit thereby optimizing the existing resources.

  12. Critical values for unit root tests in seasonal time series

    NARCIS (Netherlands)

    Ph.H.B.F. Franses (Philip Hans); B. Hobijn (Bart)

    1997-01-01

    textabstractIn this paper, we present tables with critical values for a variety of tests for seasonal and non-seasonal unit roots in seasonal time series. We consider (extensions of) the Hylleberg et al. and Osborn et al. test procedures. These extensions concern time series with increasing seasonal

  13. Decreasing laboratory turnaround time and patient wait time by implementing process improvement methodologies in an outpatient oncology infusion unit.

    Science.gov (United States)

    Gjolaj, Lauren N; Gari, Gloria A; Olier-Pino, Angela I; Garcia, Juan D; Fernandez, Gustavo L

    2014-11-01

    Prolonged patient wait times in the outpatient oncology infusion unit indicated a need to streamline phlebotomy processes by using existing resources to decrease laboratory turnaround time and improve patient wait time. Using the DMAIC (define, measure, analyze, improve, control) method, a project to streamline phlebotomy processes within the outpatient oncology infusion unit in an academic Comprehensive Cancer Center known as the Comprehensive Treatment Unit (CTU) was completed. Laboratory turnaround time for patients who needed same-day lab and CTU services and wait time for all CTU patients was tracked for 9 weeks. During the pilot, the wait time from arrival to CTU to sitting in treatment area decreased by 17% for all patients treated in the CTU during the pilot. A total of 528 patients were seen at the CTU phlebotomy location, representing 16% of the total patients who received treatment in the CTU, with a mean turnaround time of 24 minutes compared with a baseline turnaround time of 51 minutes. Streamlining workflows and placing a phlebotomy station inside of the CTU decreased laboratory turnaround times by 53% for patients requiring same day lab and CTU services. The success of the pilot project prompted the team to make the station a permanent fixture. Copyright © 2014 by American Society of Clinical Oncology.

  14. Kuninglik eesti kirjandus : hommage a Cornelius Hasselblatt / Jaan Undusk

    Index Scriptorium Estoniae

    Undusk, Jaan, 1958-

    2007-01-01

    Kõne Cornelius Hasselblatti raamatu "Geschichte der estnischen Literatur. Von den Anfängen bis zum Gegenwart" / Berlin ; New-York : Walter de Gruyter, 2006) esitlusel 1. veebruaril 2007 Tallinna Kirjanike Majas

  15. Minu kirjanduslugu / Cornelius Hasselblatt

    Index Scriptorium Estoniae

    Hasselblatt, Cornelius

    2007-01-01

    Kõne Cornelius Hasselblatti raamatu "Geschichte der estnischen Literatur. Von den Anfängen bis zum Gegenwart" / Berlin ; New-York : Walter de Gruyter, 2006) esitlusel 1. veebruaril 2007 Tallinna Kirjanike Majas

  16. Journal of EEA, Vol. 25, 2008

    African Journals Online (AJOL)

    FACE RECOGNITION USING ARTIFICIAL NEURAL NETWORK. Sentayehu Endeshaw and .... Number of statistical and Artificial Intelligence techniques have been ..... college publishing company, Newyork, 1994. [4] Hyun Jin Park and Hyun ...

  17. The influence of time units on the flexibility of the spatial numerical association of response codes effect.

    Science.gov (United States)

    Zhao, Tingting; He, Xianyou; Zhao, Xueru; Huang, Jianrui; Zhang, Wei; Wu, Shuang; Chen, Qi

    2018-05-01

    The Spatial Numerical/Temporal Association of Response Codes (SNARC/STEARC) effects are considered evidence of the association between number or time and space, respectively. As the SNARC effect was proposed by Dehaene, Bossini, and Giraux in 1993, several studies have suggested that different tasks and cultural factors can affect the flexibility of the SNARC effect. This study explored the influence of time units on the flexibility of the SNARC effect via materials with Arabic numbers, which were suffixed with time units and subjected to magnitude comparison tasks. Experiment 1 replicated the SNARC effect for numbers and the STEARC effect for time units. Experiment 2 explored the flexibility of the SNARC effect when numbers were attached to time units, which either conflicted with the numerical magnitude or in which the time units were the same or different. Experiment 3 explored whether the SNARC effect of numbers was stable when numbers were near the transition of two adjacent time units. The results indicate that the SNARC effect was flexible when the numbers were suffixed with time units: Time units influenced the direction of the SNARC effect in a way which could not be accounted for by the mathematical differences between the time units and numbers. This suggests that the SNARC effect is not obligatory and can be easily adapted or inhibited based on the current context. © 2017 The Authors. British Journal of Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.

  18. Health care aides use of time in a residential long-term care unit: a time and motion study.

    Science.gov (United States)

    Mallidou, Anastasia A; Cummings, Greta G; Schalm, Corinne; Estabrooks, Carole A

    2013-09-01

    Organizational resources such as caregiver time use with older adults in residential long-term care facilities (nursing homes) have not been extensively studied, while levels of nurse staffing and staffing-mix are the focus of many publications on all types of healthcare organizations. Evidence shows that front-line caregivers' sufficient working time with residents is associated with performance, excellence, comprehensive care, quality of outcomes (e.g., reductions in pressure ulcers, urinary tract infections, and falls), quality of life, cost savings, and may be affiliated with transformation of organizational culture. To explore organizational resources in a long-term care unit within a multilevel residential facility, to measure healthcare aides' use of time with residents, and to describe working environment and unit culture. An observational pilot study was conducted in a Canadian urban 52-bed long-term care unit within a faith-based residential multilevel care facility. A convenience sample of seven healthcare aides consented to participate. To collect the data, we used an observational sheet (to monitor caregiver time use on certain activities such as personal care, assisting with eating, socializing, helping residents to be involved in therapeutic activities, paperwork, networking, personal time, and others), semi-structured interview (to assess caregiver perceptions of their working environment), and field notes (to illustrate the unit culture). Three hundred and eighty seven hours of observation were completed. The findings indicate that healthcare aides spent most of their working time (on an eight-hour day-shift) in "personal care" (52%) and in "other" activities (23%). One-to-three minute activities consumed about 35% of the time spent in personal care and 20% of time spent in assisting with eating. Overall, caregivers' time spent socializing was less than 1%, about 6% in networking, and less than 4% in paperwork. Re-organizing healthcare aides

  19. Prescott’s Microbiology, Eighth Edition

    OpenAIRE

    Dobbins, Joanne J.

    2010-01-01

    Review of: Prescott’s Microbiology, Eighth Edition. Joanne M. Willey, Linda M. Sherwood, and Christopher J. Woolverton. 2011. McGraw-Hill Higher Education, NewYork, NY. 1070 pages. ISBN- 978-0-07-337526-7.

  20. Pricing and Hedging Quanto Options in Energy Markets

    DEFF Research Database (Denmark)

    Benth, Fred Espen; Lange, Nina; Myklebust, Tor Åge

    2015-01-01

    –Jarrow–Morton approach, we derive a closed-form option pricing formula for energy quanto options under the assumption that the underlying assets are lognormally distributed. Our approach encompasses several interesting cases, such as geometric Brownian motions and multifactor spot models. We also derive Delta and Gamma......In energy markets, the use of quanto options has increased significantly in recent years. The payoff from such options are typically written on an underlying energy index and a measure of temperature. They are suited to managing the joint price and volume risk in energy markets. Using a Heath...... expressions for hedging. Further, we illustrate the use of our model by an empirical pricing exercise using NewYork Mercantile Exchange-traded natural gas futures and Chicago Mercantile Exchange-traded heating degree days futures for NewYork....

  1. [Analysis of cost and efficiency of a medical nursing unit using time-driven activity-based costing].

    Science.gov (United States)

    Lim, Ji Young; Kim, Mi Ja; Park, Chang Gi

    2011-08-01

    Time-driven activity-based costing was applied to analyze the nursing activity cost and efficiency of a medical unit. Data were collected at a medical unit of a general hospital. Nursing activities were measured using a nursing activities inventory and classified as 6 domains using Easley-Storfjell Instrument. Descriptive statistics were used to identify general characteristics of the unit, nursing activities and activity time, and stochastic frontier model was adopted to estimate true activity time. The average efficiency of the medical unit using theoretical resource capacity was 77%, however the efficiency using practical resource capacity was 96%. According to these results, the portion of non-added value time was estimated 23% and 4% each. The sums of total nursing activity costs were estimated 109,860,977 won in traditional activity-based costing and 84,427,126 won in time-driven activity-based costing. The difference in the two cost calculating methods was 25,433,851 won. These results indicate that the time-driven activity-based costing provides useful and more realistic information about the efficiency of unit operation compared to traditional activity-based costing. So time-driven activity-based costing is recommended as a performance evaluation framework for nursing departments based on cost management.

  2. Research Article Special Issue

    African Journals Online (AJOL)

    pc

    2017-11-24

    Nov 24, 2017 ... successful application of this approach for creating mathematical models and their use in ...... Jay C. Hsu, Andrew U. Meyer, Modern control principles and applications: - New-York: McGraw-hill book company, 1972 – 544pp.

  3. Point of view of experts from Columbia university, New-york, and from University of California, Berkeley

    International Nuclear Information System (INIS)

    Brenner, D.J.; Sachs, R.K.; Donadieu, J.

    2006-01-01

    In a widely circulated document, a group of French renowned scientists from French Academia of sciences suggests that the risk of cancer induced by ionizing radiation is for the low doses smaller by unit than this one established for strong doses that is to say for the doses where an effect has been demonstrated by epidemiological studies. It suggests particularly that at very low doses, the excess of cancers could be null even negative. Although there is considerable uncertainty about the carcinogenic effect of low doses, we believe that the authors have not provided a convincing argument in favor of their hypotheses, from a quantitative point of view or a qualifying one. The main argument of the authors is based on biological arguments demonstrating that very low doses of radiation induce lesions in a limited number of cells, making possible the elimination of these cells either by cell death, or by another mechanism. Thus, one would be led to define a threshold below which there is no increased cancer risk. But the arguments do not seem sufficient to draw such conclusions. (N.C.)

  4. Educational inequalities in parental care time: Cross-national evidence from Belgium, Denmark, Spain, and the United Kingdom.

    Science.gov (United States)

    Gracia, Pablo; Ghysels, Joris

    2017-03-01

    This study uses time-diary data for dual-earner couples from Belgium, Denmark, Spain, and the United Kingdom to analyze educational inequalities in parental care time in different national contexts. For mothers, education is significantly associated with parenting involvement only in Spain and the United Kingdom. In Spain these differences are largely explained by inequalities in mothers' time and monetary resources, but not in the United Kingdom, where less-educated mothers disproportionally work in short part-time jobs. For fathers, education is associated with parenting time in Denmark, and particularly in Spain, while the wife's resources substantially drive these associations. On weekends, the educational gradient in parental care time applies only to Spain and the United Kingdom, two countries with particularly large inequalities in parents' opportunities to engage in parenting. The study shows country variations in educational inequalities in parenting, suggesting that socioeconomic resources, especially from mothers, shape important variations in parenting involvement. Copyright © 2016. Published by Elsevier Inc.

  5. Changes in time and frequency related aspects of motor unit action potentials during fatigue

    NARCIS (Netherlands)

    Wallinga, W.; Bouwens, Jeroen S.; Baten, Christian T.M.

    1996-01-01

    During fatigue the shape of motor unit action potentials (MUAPs) change. Characteristics of the MUAPs described before concern several time related aspects. No attention has been given to the frequency spectrum changes of MUAPS. The median frequency of MUAPS has now been determined for motor units

  6. Impressions de campagne d’un touriste à Manhattan.

    OpenAIRE

    Patrick Garcia

    2004-01-01

    «  Vote or die !  » — C’est ce gigantesque panneau qui m’a accueilli sur Broadway avenue, non loin de Times Square, lorsque j’ai fait mes premiers pas à New-York, lundi 25 octobre 2004. Ainsi donc j’y étais ! J’allais, non sans une certaine excitation, prendre le pouls de l’élection-monde, celle qui renvoie toutes les autres au statut d’élections locales. Effectivement, ce slogan lancé par l’association Citizen Change 1 a rythmé mon séjour à Manhattan. Je ...

  7. Motivated information processing and group decision-making : Effects of process accountability on information processing and decision quality

    NARCIS (Netherlands)

    Scholten, Lotte; van Knippenberg, Daan; Nijstad, Bernard A.; De Dreu, Carsten K. W.

    Integrating dual-process models [Chaiken, S., & Trope, Y. (Eds.). (1999). Dual-process theories in social psychology. NewYork: Guilford Press] with work on information sharing and group decision-making [Stasser, G., & Titus, W. (1985). Pooling of unshared information in group decision making: biased

  8. A "Neurological Emergency Trolley" reduces turnaround time for high-risk medications in a general intensive care unit.

    Science.gov (United States)

    Ajzenberg, Henry; Newman, Paula; Harris, Gail-Anne; Cranston, Marnie; Boyd, J Gordon

    2018-02-01

    To reduce medication turnaround times during neurological emergencies, a multidisciplinary team developed a neurological emergency crash trolley in our intensive care unit. This trolley includes phenytoin, hypertonic saline and mannitol, as well as other equipment. The aim of this study was to assess whether the cart reduced turnaround times for these medications. In this retrospective cohort study, medication delivery times for two year epochs before and after its implementation were compared. Eligible patients were identified from our intensive care unit screening log. Adults who required emergent use of phenytoin, hypertonic saline or mannitol while in the intensive care unit were included. Groups were compared with nonparametric analyses. 33-bed general medical-surgical intensive care unit in an academic teaching hospital. Time to medication administration. In the pre-intervention group, there were 43 patients with 66 events. In the post-intervention group, there were 45 patients with 80 events. The median medication turnaround time was significantly reduced after implementation of the neurological emergency trolley (25 vs. 10minutes, p=0.003). There was no statistically significant difference in intensive care or 30-day survival between the two cohorts. The implementation of a novel neurological emergency crash trolley in our intensive care unit reduced medication turnaround times. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Rest life time management of Kozloduy NPPP Unit 3 and 4

    International Nuclear Information System (INIS)

    Vodenicharov, St.

    2002-01-01

    The radiation life time of reactor pressure vessel (RPV) is the most important limiting factor for the term of exploitation of the whole power unit. The main degradation mechanism of RPV metal is the neutron induced embrittlement. Processes of radiation ageing running in RPV metal lead to fracture toughness decrease and to increased probability of brittle fracture of the vessel under thermal shocks. This explains the importance of RPV integrity assessment and rest life time management

  10. WHAT ON EARTH HAPPENED TO THE ACCOUNTING PROFESSION (ABSTRACT

    Directory of Open Access Journals (Sweden)

    Jerome J. DeRidder

    2004-01-01

    Full Text Available The Accounting Profession in the United States began with the 1896 NewYork Bill which provided for an examination to become a “Certified Public Accountant.”During this early period the professional accountant searched for the fairest presentation of financial data. The auditors responsibilities were not clearly defined nor were there any “Generally Accepted Principles.”Over the years, efforts were made to improve the level of financial reporting by the New York Stock Exchange, the Investment Bankers Association and by the Accounting Profession; however, they lacked authority to enforce their recommendations.Many times the profession was several criticized for their lack of uniform standards, relying upon precedent rather than using the scientific method and sometimes yielding to industry pressure on important issues. In 1956, Mr. Spacek, the managing partner of Arthur Anderson and Co. made a prophetic statement when at a commerce and industry luncheon he stated that the profession: “must wait for the CATASTROPHE — because we do not have a self-appraising profession.”Arthur Anderson and Co. no longer exists due to accounting fraud and irregularities. The Securities and Exchange Commission empowered by the SARBANES-OXLEY Act established a New Accounting Oversight Board Profession and they control the accounting Profession in the United States.

  11. FRAMING Linguistics: ``SEANCES"(!!!) Martin-Bradshaw-Siegel ``Buzzwordism, Bandwagonism, Sloganeering For:Fun, Profit, Survival, Ego": Rampant UNethics Sociological-DYSfunctionality!!!

    Science.gov (United States)

    Bradshaw, John; Siegel, E.

    2010-03-01

    ``Sciences''/SEANCES(!!!) rampant UNethics!!! WITNESS: Yau v Perelman Poincare-conj.-pf. [Naser, NewYorker(8/06)]; digits log- law Siegel[AMS Nat.Mtg.(02)-Abs.973-60-124] inversion to ONLY BEQS: Newcomb(1881)theory method[Doyle-Snell, Random-Walks/Electric-Nets (81)]: 1881Ethics? SHMETHICS!!!

  12. Different contexts, different effects? Work time and mental health in the United States and Germany.

    Science.gov (United States)

    Kleiner, Sibyl; Schunck, Reinhard; Schömann, Klaus

    2015-03-01

    This paper takes a comparative approach to the topic of work time and health, asking whether weekly work hours matter for mental health. We hypothesize that these relationships differ within the United States and Germany, given the more regulated work time environments within Germany and the greater incentives to work long hours in the United States. We further hypothesize that German women will experience greatest penalties to long hours. We use data from the German Socioeconomic Panel and the National Longitudinal Survey of Youth to examine hours effects on mental health score at midlife. The results support our initial hypothesis. In Germany, longer work time is associated with worse mental health, while in the United States, as seen in previous research, the associations are more complex. Our results do not show greater mental health penalties for German women and suggest instead a selection effect into work hours operating by gender. © American Sociological Association 2015.

  13. "Units of Comparison" across Languages, across Time

    Science.gov (United States)

    Thomas, Margaret

    2009-01-01

    Lardiere's keynote article adverts to a succession of "units of comparison" that have been employed in the study of cross-linguistic differences, including mid-twentieth-century structural patterns, generative grammar's parameters, and (within contemporary Minimalism) features. This commentary expands on the idea of units of cross-linguistic…

  14. The Magnitude and Time Course of Muscle Cross-section Decrease in Intensive Care Unit Patients

    NARCIS (Netherlands)

    Haaf, D. Ten; Hemmen, B.; Meent, H. van de; Bovend'Eerdt, T.J.H.

    2017-01-01

    OBJECTIVE: Bedriddenness and immobilization of patients at an intensive care unit may result in muscle atrophy and devaluation in quality of life. The exact effect of immobilization on intensive care unit patients is not known. The aim of this study was to investigate the magnitude and time course

  15. Obesity, diabetes, and length of time in the United States

    OpenAIRE

    Tsujimoto, Tetsuro; Kajio, Hiroshi; Sugiyama, Takehiro

    2016-01-01

    Abstract Obesity prevalence remains high in the United States (US), and is rising in most other countries. This is a repeated cross-sectional study using a nationally representative sample of the National Health and Nutrition Examination Survey 1999 to 2012. Multivariate logistic regression analyses were separately performed for adults (n?=?37,639) and children/adolescents (n?=?28,282) to assess the associations between the length of time in the US, and the prevalences of obesity and diabetes...

  16. Microcontroller based resonance tracking unit for time resolved continuous wave cavity-ringdown spectroscopy measurements.

    Science.gov (United States)

    Votava, Ondrej; Mašát, Milan; Parker, Alexander E; Jain, Chaithania; Fittschen, Christa

    2012-04-01

    We present in this work a new tracking servoloop electronics for continuous wave cavity-ringdown absorption spectroscopy (cw-CRDS) and its application to time resolved cw-CRDS measurements by coupling the system with a pulsed laser photolysis set-up. The tracking unit significantly increases the repetition rate of the CRDS events and thus improves effective time resolution (and/or the signal-to-noise ratio) in kinetics studies with cw-CRDS in given data acquisition time. The tracking servoloop uses novel strategy to track the cavity resonances that result in a fast relocking (few ms) after the loss of tracking due to an external disturbance. The microcontroller based design is highly flexible and thus advanced tracking strategies are easy to implement by the firmware modification without the need to modify the hardware. We believe that the performance of many existing cw-CRDS experiments, not only time-resolved, can be improved with such tracking unit without any additional modification to the experiment. © 2012 American Institute of Physics

  17. Impressions de campagne d’un touriste à Manhattan.

    Directory of Open Access Journals (Sweden)

    Patrick Garcia

    2004-11-01

    Full Text Available «  Vote or die !  » — C’est ce gigantesque panneau qui m’a accueilli sur Broadway avenue, non loin de Times Square, lorsque j’ai fait mes premiers pas à New-York, lundi 25 octobre 2004. Ainsi donc j’y étais ! J’allais, non sans une certaine excitation, prendre le pouls de l’élection-monde, celle qui renvoie toutes les autres au statut d’élections locales. Effectivement, ce slogan lancé par l’association Citizen Change 1 a rythmé mon séjour à Manhattan. Je ...

  18. Detection and attribution of streamflow timing changes to climate change in the Western United States

    Science.gov (United States)

    Hidalgo, H.G.; Das, T.; Dettinger, M.D.; Cayan, D.R.; Pierce, D.W.; Barnett, T.P.; Bala, G.; Mirin, A.; Wood, A.W.; Bonfils, Celine; Santer, B.D.; Nozawa, T.

    2009-01-01

    This article applies formal detection and attribution techniques to investigate the nature of observed shifts in the timing of streamflow in the western United States. Previous studies have shown that the snow hydrology of the western United States has changed in the second half of the twentieth century. Such changes manifest themselves in the form of more rain and less snow, in reductions in the snow water contents, and in earlier snowmelt and associated advances in streamflow "center" timing (the day in the "water-year" on average when half the water-year flow at a point has passed). However, with one exception over a more limited domain, no other study has attempted to formally attribute these changes to anthropogenic increases of greenhouse gases in the atmosphere. Using the observations together with a set of global climate model simulations and a hydrologic model (applied to three major hydrological regions of the western United States_the California region, the upper Colorado River basin, and the Columbia River basin), it is found that the observed trends toward earlier "center" timing of snowmelt-driven streamflows in the western United States since 1950 are detectably different from natural variability (significant at the p analysis, and it is the only basin that showed a detectable signal when the analysis was performed on individual basins. It should be noted that although climate change is an important signal, other climatic processes have also contributed to the hydrologic variability of large basins in the western United States. ?? 2009 American Meteorological Society.

  19. Working at the Weekend: Fathers' Time with Family in the United Kingdom.

    Science.gov (United States)

    Hook, Jennifer L

    2012-08-01

    Whereas most resident fathers are able to spend more time with their children on weekends than on weekdays, many fathers work on the weekends spending less time with their children on these days. There are conflicting findings about whether fathers are able to make up for lost weekend time on weekdays. Using unique features of the United Kingdom's National Survey of Time Use 2000 (UKTUS) I examine the impact of fathers' weekend work on the time fathers spend with their children, family, and partners (N = 595 fathers). I find that weekend work is common among fathers and is associated with less time with children, families, and partners. Fathers do not recover lost time with children on weekdays, largely because weekend work is a symptom of overwork. Findings also reveal that even if fathers had compensatory time, they are unlikely to recover lost time spent as a family or couple.

  20. Time-of-flight data acquisition unit (DAU) for neutron scattering experiments. Specification of the requirements and design concept. Version 3.1

    International Nuclear Information System (INIS)

    Herdam, G.; Klessmann, H.; Wawer, W.; Adebayo, J.; David, G.; Szatmari, F.

    1989-12-01

    This specification describes the requirements for the Data Acquisition Unit (DAU) and defines the design concept for the functional units involved. The Data Acquisition Unit will be used in the following neutron scattering experiments: Time-of-Flight Spectrometer NEAT, Time-of-Flight Spectrometer SPAN. In addition, the data of the SPAN spectrometer in Spin Echo experiments will be accumulated. The Data Acquisition Unit can be characterised by the following requirements: Time-of-flight measurement with high time resolution (125 ns), sorting the time-of-flight in up to 4096 time channels (channel width ≥ 1 μs), selection of different time channel widths for peak and background, on-line time-of-flight correction for neutron flight paths of different lengths, sorting the detector position information in up to 4096 position channels, accumulation of two-dimensional spectra in a 32 Mbyte RAM memory (4 K time channels*4 K position channels*16 bits). Because of the stringent timing requirements the functional units of the DAU are hardware controlled via tables. The DAU is part of a process control system which has access to the functional units via the VMEbus in order to initialise, to load tables and control information, and to read status information and spectra. (orig.) With 18 figs

  1. Study of Track Irregularity Time Series Calibration and Variation Pattern at Unit Section

    Directory of Open Access Journals (Sweden)

    Chaolong Jia

    2014-01-01

    Full Text Available Focusing on problems existing in track irregularity time series data quality, this paper first presents abnormal data identification, data offset correction algorithm, local outlier data identification, and noise cancellation algorithms. And then proposes track irregularity time series decomposition and reconstruction through the wavelet decomposition and reconstruction approach. Finally, the patterns and features of track irregularity standard deviation data sequence in unit sections are studied, and the changing trend of track irregularity time series is discovered and described.

  2. 76 FR 45508 - Polyethylene Terephthalate Film, Sheet and Strip From the United Arab Emirates: Extension of Time...

    Science.gov (United States)

    2011-07-29

    ... Film, Sheet and Strip From the United Arab Emirates: Extension of Time Limit for Preliminary Results of... polyethylene terephthalate film, sheet and strip from the United Arab Emirates (UAE) for the period November 01... producer and/or exporter of the subject merchandise to the United States: JBF RAK LLC (JBF). Extension of...

  3. Operation time extension for power units of the first generation NPP and the liability for potential damage

    International Nuclear Information System (INIS)

    Kovalevich, O.M.

    2000-01-01

    The problem on the operation time extension for the six operating NPP first generation power units is discussed. However it is not advisable to improve the safety of these power units up to the acceptable level, therefore there arises the contradiction between the operation time extension of these power units and potential damage for the population. The possibility of having the increased civilian-legal responsibility for potential harm and losses in case of an accident is proposed to be considered as a compensating measure. The measures for realization of this civilian-legal responsibility are described [ru

  4. Age and admission times as predictive factors for failure of admissions to discharge-stream short-stay units.

    Science.gov (United States)

    Shetty, Amith L; Shankar Raju, Savitha Banagar; Hermiz, Arsalan; Vaghasiya, Milan; Vukasovic, Matthew

    2015-02-01

    Discharge-stream emergency short-stay units (ESSU) improve ED and hospital efficiency. Age of patients and time of hospital presentations have been shown to correlate with increasing complexity of care. We aim to determine whether an age and time cut-off could be derived to subsequently improve short-stay unit success rates. We conducted a retrospective audit on 6703 (5522 inclusions) patients admitted to our discharge-stream short-stay unit. Patients were classified as appropriate or inappropriate admissions, and deemed successful if discharged out of the unit within 24 h; and failures if they needed inpatient admission into the hospital. We calculated short-stay unit length of stay for patients in each of these groups. A 15% failure rate was deemed as acceptable key performance indicator (KPI) for our unit. There were 197 out of 4621 (4.3%, 95% CI 3.7-4.9%) patients up to the age of 70 who failed admission to ESSU compared with 67 out of 901 (7.4%, 95% CI 5.9-9.3%, P 70 years of age have higher rates of failure after admission to discharge-stream ESSU. Although in appropriately selected discharge-stream patients, no age group or time-band of presentation was associated with increased failure rate beyond the stipulated KPI. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  5. Real-time radar signal processing using GPGPU (general-purpose graphic processing unit)

    Science.gov (United States)

    Kong, Fanxing; Zhang, Yan Rockee; Cai, Jingxiao; Palmer, Robert D.

    2016-05-01

    This study introduces a practical approach to develop real-time signal processing chain for general phased array radar on NVIDIA GPUs(Graphical Processing Units) using CUDA (Compute Unified Device Architecture) libraries such as cuBlas and cuFFT, which are adopted from open source libraries and optimized for the NVIDIA GPUs. The processed results are rigorously verified against those from the CPUs. Performance benchmarked in computation time with various input data cube sizes are compared across GPUs and CPUs. Through the analysis, it will be demonstrated that GPGPUs (General Purpose GPU) real-time processing of the array radar data is possible with relatively low-cost commercial GPUs.

  6. Decreasing Postanesthesia Care Unit to Floor Transfer Times to Facilitate Short Stay Total Joint Replacements.

    Science.gov (United States)

    Sibia, Udai S; Grover, Jennifer; Turcotte, Justin J; Seanger, Michelle L; England, Kimberly A; King, Jennifer L; King, Paul J

    2018-04-01

    We describe a process for studying and improving baseline postanesthesia care unit (PACU)-to-floor transfer times after total joint replacements. Quality improvement project using lean methodology. Phase I of the investigational process involved collection of baseline data. Phase II involved developing targeted solutions to improve throughput. Phase III involved measured project sustainability. Phase I investigations revealed that patients spent an additional 62 minutes waiting in the PACU after being designated ready for transfer. Five to 16 telephone calls were needed between the PACU and the unit to facilitate each patient transfer. The most common reason for delay was unavailability of the unit nurse who was attending to another patient (58%). Phase II interventions resulted in transfer times decreasing to 13 minutes (79% reduction, P care at other institutions. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  7. Development of a processor embedded timing unit for the synchronized operation in KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woongryol, E-mail: wrlee@nfri.re.kr; Lee, Taegu; Hong, Jaesic

    2016-11-15

    Highlights: • Timing board for the synchronized tokamak operation. • Processor embedded distributed control system. • Single clock source and multiple trigger signal for the plasma diagnostics. • Delay compensation among the distributed timing boards. - Abstract: The Local Timing Unit (LTU) in KSTAR provides a single clock source and multiple trigger signals with flexible configuration. Over the past seven years, the LTU had a mechanical redesign and several firmware updates for the purpose of provision of a robust operation and precision timing signal. Now we have developed a third version of a local timing unit which has a standalone operation capability. The LTU is built in a cabinet mountable 1U PIZZA box and provides twelve signal output ports, a packet mirroring interface, and an LCD interface panel. The core functions of the LTU are implemented in a Field Programmable Gate Array (FPGA) which has an internal hardcore processor. The internal processor allows the use of Linux Operating System (OS) and the Experimental Physics and Industrial Control System (EPICS). All user level application functions are controllable through the EPICS, however the time critical internal functions are performed by the FPGA logic blocks same as the previous version. The new LTU provides pluggable output module so that we can easily extend the signal output port. The easy installation and effective replacement reduce the efforts of maintenance. This paper describes design, development, and commissioning results of the new KSTAR LTU.

  8. Development of a processor embedded timing unit for the synchronized operation in KSTAR

    International Nuclear Information System (INIS)

    Lee, Woongryol; Lee, Taegu; Hong, Jaesic

    2016-01-01

    Highlights: • Timing board for the synchronized tokamak operation. • Processor embedded distributed control system. • Single clock source and multiple trigger signal for the plasma diagnostics. • Delay compensation among the distributed timing boards. - Abstract: The Local Timing Unit (LTU) in KSTAR provides a single clock source and multiple trigger signals with flexible configuration. Over the past seven years, the LTU had a mechanical redesign and several firmware updates for the purpose of provision of a robust operation and precision timing signal. Now we have developed a third version of a local timing unit which has a standalone operation capability. The LTU is built in a cabinet mountable 1U PIZZA box and provides twelve signal output ports, a packet mirroring interface, and an LCD interface panel. The core functions of the LTU are implemented in a Field Programmable Gate Array (FPGA) which has an internal hardcore processor. The internal processor allows the use of Linux Operating System (OS) and the Experimental Physics and Industrial Control System (EPICS). All user level application functions are controllable through the EPICS, however the time critical internal functions are performed by the FPGA logic blocks same as the previous version. The new LTU provides pluggable output module so that we can easily extend the signal output port. The easy installation and effective replacement reduce the efforts of maintenance. This paper describes design, development, and commissioning results of the new KSTAR LTU.

  9. Dynamic Agricultural Land Unit Profile Database Generation using Landsat Time Series Images

    Science.gov (United States)

    Torres-Rua, A. F.; McKee, M.

    2012-12-01

    Agriculture requires continuous supply of inputs to production, while providing final or intermediate outputs or products (food, forage, industrial uses, etc.). Government and other economic agents are interested in the continuity of this process and make decisions based on the available information about current conditions within the agriculture area. From a government point of view, it is important that the input-output chain in agriculture for a given area be enhanced in time, while any possible abrupt disruption be minimized or be constrained within the variation tolerance of the input-output chain. The stability of the exchange of inputs and outputs becomes of even more important in disaster-affected zones, where government programs will look for restoring the area to equal or enhanced social and economical conditions before the occurrence of the disaster. From an economical perspective, potential and existing input providers require up-to-date, precise information of the agriculture area to determine present and future inputs and stock amounts. From another side, agriculture output acquirers might want to apply their own criteria to sort out present and future providers (farmers or irrigators) based on the management done during the irrigation season. In the last 20 years geospatial information has become available for large areas in the globe, providing accurate, unbiased historical records of actual agriculture conditions at individual land units for small and large agricultural areas. This data, adequately processed and stored in any database format, can provide invaluable information for government and economic interests. Despite the availability of the geospatial imagery records, limited or no geospatial-based information about past and current farming conditions at the level of individual land units exists for many agricultural areas in the world. The absence of this information challenges the work of policy makers to evaluate previous or current

  10. Time use and physical activity in a specialised brain injury rehabilitation unit: an observational study.

    Science.gov (United States)

    Hassett, Leanne; Wong, Siobhan; Sheaves, Emma; Daher, Maysaa; Grady, Andrew; Egan, Cara; Seeto, Carol; Hosking, Talia; Moseley, Anne

    2018-04-18

    To determine what is the use of time and physical activity in people undertaking inpatient rehabilitation in a specialised brain injury unit. To determine participants' level of independence related to the use of time and physical activity. Design: Cross-sectional observation study. Fourteen people [mean (SD) age 40 (15) years] with brain injuries undertaking inpatient rehabilitation. Participants were observed every 12 minutes over 5 days (Monday to Friday from 7:30 am until 7:30 pm) using a behaviour mapping tool. Observation of location, people present, body position and activity engaged in (both therapeutic and nontherapeutic). Functional Independence Measure (FIM) scores were determined for each participant. Participants spent a large part of their time alone (34%) in sedentary positions (83%) and in their bedrooms (48%) doing non-therapeutic activities (78%). There was a positive relationship between a higher level of independence (higher FIM score) and being observed in active body positions (r=0.60; p=0.03) and participating in physically active therapeutic activities (r=0.53; p=0.05). Similar to stroke units, inpatients in a specialised brain injury unit spend large parts of the day sedentary, alone and doing non-therapeutic activities. Strategies need to be evaluated to address this problem, particularly for people with greater physical dependence.

  11. Creating Deep Time Diaries: An English/Earth Science Unit for Middle School Students

    Science.gov (United States)

    Jordan, Vicky; Barnes, Mark

    2006-01-01

    Students love a good story. That is why incorporating literary fiction that parallels teaching goals and standards can be effective. In the interdisciplinary, thematic six-week unit described in this article, the authors use the fictional book "The Deep Time Diaries," by Gary Raham, to explore topics in paleontology, Earth science, and creative…

  12. Evaluation of the body bearing of high performance female volleyball players

    Directory of Open Access Journals (Sweden)

    Stech M.

    2010-09-01

    Full Text Available In the present paper the results of the study of body bearing in 12 high performance female volleyball players of polish team (TPS Rumia are presented. To estimate body bearing the New-York's test of the body bearing classification was used. The results of the study have shown that asymmetrical positions of volleyball players in the time of services and attacks are contributed to formed some asymmetrical disturbances of body bearing. At the majority of sportsmen it is exhibited in omitting the left brachium and the left blade, in a right-hand scoliosis, in the tendency to a platypodia. It requires use of special preventive and adjusting exercises.

  13. Referral Regions for Time-Sensitive Acute Care Conditions in the United States.

    Science.gov (United States)

    Wallace, David J; Mohan, Deepika; Angus, Derek C; Driessen, Julia R; Seymour, Christopher M; Yealy, Donald M; Roberts, Mark M; Kurland, Kristen S; Kahn, Jeremy M

    2018-03-24

    Regional, coordinated care for time-sensitive and high-risk medical conditions is a priority in the United States. A necessary precursor to coordinated regional care is regions that are actionable from clinical and policy standpoints. The Dartmouth Atlas of Health Care, the major health care referral construct in the United States, uses regions that cross state and county boundaries, limiting fiscal or political ownership by key governmental stakeholders in positions to create incentive and regulate regional care coordination. Our objective is to develop and evaluate referral regions that define care patterns for patients with acute myocardial infraction, acute stroke, or trauma, yet also preserve essential political boundaries. We developed a novel set of acute care referral regions using Medicare data in the United States from 2011. For acute myocardial infraction, acute stroke, or trauma, we iteratively aggregated counties according to patient home location and treating hospital address, using a spatial algorithm. We evaluated referral political boundary preservation and spatial accuracy for each set of referral regions. The new set of referral regions, the Pittsburgh Atlas, had 326 distinct regions. These referral regions did not cross any county or state borders, whereas 43.1% and 98.1% of all Dartmouth Atlas hospital referral regions crossed county and state borders. The Pittsburgh Atlas was comparable to the Dartmouth Atlas in measures of spatial accuracy and identified larger at-risk populations for all 3 conditions. A novel and straightforward spatial algorithm generated referral regions that were politically actionable and accountable for time-sensitive medical emergencies. Copyright © 2018 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  14. (quinolin-5-yl)urea as a host for distinction of phthalic acid and ...

    Indian Academy of Sciences (India)

    Department of Chemistry, Indian Institute of Technology Guwahati, North Guwahati 781 039, India e-mail: ... well-known in both in solid and in solution state.1–5. Hosts having urea ..... References. 1. Byrne P, Turner D R, Lloyd G O, Clarke N and Steed ... 2002 In Handbook of pharmaceutical salts (New-York: Wiley-VCH). 9.

  15. The Coast Artillery Journal. Volume 63, Number 3, September 1925

    Science.gov (United States)

    1925-09-01

    joined by the Antartic of LiverpooL On the 4th and 5th all survivors were transferred to these two vessels. The Three Bells sailed for :NewYork. The... Antartic carried her 142 survivors to Liverpool, England, which port was reached January 23; the first American troops to land in England. On February 1st

  16. [Real-time safety audits in a neonatal unit].

    Science.gov (United States)

    Bergon-Sendin, Elena; Perez-Grande, María Del Carmen; Lora-Pablos, David; Melgar-Bonis, Ana; Ureta-Velasco, Noelia; Moral-Pumarega, María Teresa; Pallas-Alonso, Carmen Rosa

    2017-09-01

    Random audits are a safety tool to help in the prevention of adverse events, but they have not been widely used in hospitals. The aim of the study was to determine, through random safety audits, whether the information and material required for resuscitation were available for each patient in a neonatal intensive care unit and determine if factors related to the patient, time or location affect the implementation of the recommendations. Prospective observational study conducted in a level III-C neonatal intensive care unit during the year 2012. The evaluation of written information on the endotracheal tube, mask and ambu bag prepared of each patient and laryngoscopes of the emergency trolley were included within a broader audit of technological resources and study procedures. The technological resources and procedures were randomly selected twice a week for audit. Appropriate overall use was defined when all evaluated variables were correctly programmed in the same procedure. A total of 296 audits were performed. The kappa coefficient of inter-observer agreement was 0.93. The rate of appropriate overall use of written information and material required for resuscitation was 62.50% (185/296). Mask and ambu bag prepared for each patient was the variable with better compliance (97.3%, P=.001). Significant differences were found with improved usage during weekends versus working-day (73.97 vs. 58.74%, P=.01), and the rest of the year versus 3 rd quarter (66.06 vs. 52%, P=.02). Only in 62.5% of cases was the information and the material necessary to attend to a critical situation urgently easily available. Opportunities for improvement were identified through the audits. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis.

    Science.gov (United States)

    Foley, Joe P; Blackney, Donna M; Ennis, Erin J

    2017-11-10

    The origins of the peak capacity concept are described and the important contributions to the development of that concept in chromatography and electrophoresis are reviewed. Whereas numerous quantitative expressions have been reported for one- and two-dimensional separations, most are focused on chromatographic separations and few, if any, quantitative unbiased expressions have been developed for capillary or microchip zone electrophoresis. Making the common assumption that longitudinal diffusion is the predominant source of zone broadening in capillary electrophoresis, analytical expressions for the peak capacity are derived, first in terms of migration time, diffusion coefficient, migration distance, and desired resolution, and then in terms of the remaining underlying fundamental parameters (electric field, electroosmotic and electrophoretic mobilities) that determine the migration time. The latter expressions clearly illustrate the direct square root dependence of peak capacity on electric field and migration distance and the inverse square root dependence on solute diffusion coefficient. Conditions that result in a high peak capacity will result in a low peak capacity per unit time and vice-versa. For a given symmetrical range of relative electrophoretic mobilities for co- and counter-electroosmotic species (cations and anions), the peak capacity increases with the square root of the electric field even as the temporal window narrows considerably, resulting in a significant reduction in analysis time. Over a broad relative electrophoretic mobility interval [-0.9, 0.9], an approximately two-fold greater amount of peak capacity can be generated for counter-electroosmotic species although it takes about five-fold longer to do so, consistent with the well-known bias in migration time and resolving power for co- and counter-electroosmotic species. The optimum lower bound of the relative electrophoretic mobility interval [μ r,Z , μ r,A ] that provides the maximum

  18. Breastfeeding protection, promotion, and support in the United States: a time to nudge, a time to measure.

    Science.gov (United States)

    Pérez-Escamilla, Rafael; Chapman, Donna J

    2012-05-01

    Strong evidence-based advocacy efforts have now translated into high level political support and concrete goals for improving breastfeeding outcomes among women in the United States. In spite of this, major challenge remain for promoting, supporting and especially for protecting breastfeeding in the country. The goals of this commentary are to argue in favor of: A) Changes in the default social and environmental systems, that would allow women to implement their right to breastfeed their infants, B) A multi-level and comprehensive monitoring system to measure process and outcomes indicators in the country. Evidence-based commentary. Breastfeeding rates in the United States can improve based on a well coordinated social marketing framework. This approach calls for innovative promotion through mass media, appropriate facility based and community based support (e.g., Baby Friendly Hospital Initiative, WIC-coordinated community based peer counseling), and adequate protection for working women (e.g., longer paid maternity leave, breastfeeding or breast milk extraction breaks during the working day) and women at large by adhering and enforcing the WHO ethics Code for the Marketing of Breast Milk Substitutes. Sound infant feeding practices monitoring systems, which include WIC administrative food package data, are needed. Given the current high level of political support to improve breastfeeding in the United States, a window of opportunity has been opened. Establishing breastfeeding as the social norm in the USA will take time, but the global experience indicates that it can be done.

  19. Units of measurement past, present and future international system of units

    CERN Document Server

    Gupta, S V

    2010-01-01

    It is for the first time that the subject of quantities and their respective units is dealt this much in detail a glimpse of units of measurements of base quantities of length, time, mass and volume is given for ancient India three and four dimensional systems of measurement units are critically examined establishment of the fact that only four base units are needed to describe a system of units the basics to arrive at the unit of a derived quantity are explained basic, derived and dimensionless quantities including quantity calculus are introduced life history of scientists concerned with measurements units are presented to be inspiring to working metrologists and students. The International System of Units including, Metre Convention Treaty and its various organs including International National of Weights and Measure are described. The realisation of base units is given in detail. Classes of derived units within the SI, units permitted for time to come, units outside SI but used in special fields of measur...

  20. Maximizing the retention level for proportional reinsurance under  -regulation of the finite time surplus process with unit-equalized interarrival time

    Directory of Open Access Journals (Sweden)

    Sukanya Somprom

    2016-07-01

    Full Text Available The research focuses on an insurance model controlled by proportional reinsurance in the finite-time surplus process with a unit-equalized time interval. We prove the existence of the maximal retention level for independent and identically distributed claim processes under α-regulation, i.e., a model where the insurance company has to manage the probability of insolvency to be at most α. In addition, we illustrate the maximal retention level for exponential claims by applying the bisection technique.

  1. Prospective Trial of House Staff Time to Response and Intervention in a Surgical Intensive Care Unit: Pager vs. Smartphone.

    Science.gov (United States)

    Tatum, James M; White, Terris; Kang, Christopher; Ley, Eric J; Melo, Nicolas; Bloom, Matthew; Alban, Rodrigo F

    The objective of the study was to characterize house staff time to response and intervention when notified of a patient care issue by pager vs. smartphone. We hypothesized that smartphones would reduce house staff time to response and intervention. Prospective study of all electronic communications was conducted between nurses and house staff between September 2015 and October 2015. The 4-week study period was randomly divided into two 2-week study periods where all electronic communications between intensive care unit nurses and intensive care unit house staff were exclusively by smartphone or by pager, respectively. Time of communication initiation, time of house staff response, and time from response to clinical intervention for each communication were recorded. Outcomes are time from nurse contact to house staff response and intervention. Single-center surgical intensive care unit of Cedars-Sinai Medical Center in Los Angeles, California, an academic tertiary care and level I trauma center. All electronic communications occurring between nurses and house staff in the study unit during the study period were considered. During the study period, 205 nurse-house staff electronic communications occurred, 100 in the phone group and 105 in the pager group. House staff response to communication time was significantly shorter in the phone group (0.5 [interquartile range = 1.7] vs. 2 [3]min, p house staff intervention after response was also significantly more rapid in the phone group (0.8 [1.7] vs. 1 [2]min, p = 0.003). Dedicated clinical smartphones significantly decrease time to house staff response after electronic nursing communications compared with pagers. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  2. The impact of financial and nonfinancial incentives on business-unit outcomes over time.

    Science.gov (United States)

    Peterson, Suzanne J; Luthans, Fred

    2006-01-01

    Unlike previous behavior management research, this study used a quasi-experimental, control group design to examine the impact of financial and nonfinancial incentives on business-unit (21 stores in a fast-food franchise corporation) outcomes (profit, customer service, and employee turnover) over time. The results showed that both types of incentives had a significant impact on all measured outcomes. The financial incentive initially had a greater effect on all 3 outcomes, but over time, the financial and nonfinancial incentives had an equally significant impact except in terms of employee turnover. (c) 2006 APA, all rights reserved.

  3. Unitals and ovals of symmetric block designs in LDPC and space-time coding

    Science.gov (United States)

    Andriamanalimanana, Bruno R.

    2004-08-01

    An approach to the design of LDPC (low density parity check) error-correction and space-time modulation codes involves starting with known mathematical and combinatorial structures, and deriving code properties from structure properties. This paper reports on an investigation of unital and oval configurations within generic symmetric combinatorial designs, not just classical projective planes, as the underlying structure for classes of space-time LDPC outer codes. Of particular interest are the encoding and iterative (sum-product) decoding gains that these codes may provide. Various small-length cases have been numerically implemented in Java and Matlab for a number of channel models.

  4. Software architecture for a multi-purpose real-time control unit for research purposes

    Science.gov (United States)

    Epple, S.; Jung, R.; Jalba, K.; Nasui, V.

    2017-05-01

    A new, freely programmable, scalable control system for academic research purposes was developed. The intention was, to have a control unit capable of handling multiple PT1000 temperature sensors at reasonable accuracy and temperature range, as well as digital input signals and providing powerful output signals. To take full advantage of the system, control-loops are run in real time. The whole eight bit system with very limited memory runs independently of a personal computer. The two on board RS232 connectors allow to connect further units or to connect other equipment, as required in real time. This paper describes the software architecture for the third prototype that now provides stable measurements and an improvement in accuracy compared to the previous designs. As test case a thermal solar system to produce hot tap water and assist heating in a single-family house was implemented. The solar fluid pump was power-controlled and several temperatures at different points in the hydraulic system were measured and used in the control algorithms. The software architecture proved suitable to test several different control strategies and their corresponding algorithms for the thermal solar system.

  5. Fall risk as a function of time after admission to sub-acute geriatric hospital units.

    Science.gov (United States)

    Rapp, Kilian; Ravindren, Johannes; Becker, Clemens; Lindemann, Ulrich; Jaensch, Andrea; Klenk, Jochen

    2016-10-07

    There is evidence about time-dependent fracture rates in different settings and situations. Lacking are data about underlying time-dependent fall risk patterns. The objective of the study was to analyse fall rates as a function of time after admission to sub-acute hospital units and to evaluate the time-dependent impact of clinical factors at baseline on fall risk. This retrospective cohort study used data of 5,255 patients admitted to sub-acute units in a geriatric rehabilitation clinic in Germany between 2010 and 2014. Falls, personal characteristics and functional status at admission were extracted from the hospital information system. The rehabilitation stay was divided in 3-day time-intervals. The fall rate was calculated for each time-interval in all patients combined and in subgroups of patients. To analyse the influence of covariates on fall risk over time multivariate negative binomial regression models were applied for each of 5 time-intervals. The overall fall rate was 10.2 falls/1,000 person-days with highest fall risks during the first week and decreasing risks within the following weeks. A particularly pronounced risk pattern with high fall risks during the first days and decreasing risks thereafter was observed in men, disoriented people, and people with a low functional status or impaired cognition. In disoriented patients, for example, the fall rate decreased from 24.6 falls/1,000 person-days in day 2-4 to about 13 falls/1,000 person-days 2 weeks later. The incidence rate ratio of baseline characteristics changed also over time. Fall risk differs considerably over time during sub-acute hospitalisation. The strongest association between time and fall risk was observed in functionally limited patients with high risks during the first days after admission and declining risks thereafter. This should be considered in the planning and application of fall prevention measures.

  6. Plant Outage Time Savings Provided by Subcritical Physics Testing at Vogtle Unit 2

    International Nuclear Information System (INIS)

    Cupp, Philip; Heibel, M.D.

    2006-01-01

    The most recent core reload design verification physics testing done at Southern Nuclear Company's (SNC) Vogtle Unit 2, performed prior to initial power operations in operating cycle 12, was successfully completed while the reactor was at least 1% ΔK/K subcritical. The testing program used was the first application of the Subcritical Physics Testing (SPT) program developed by the Westinghouse Electric Company LLC. The SPT program centers on the application of the Westinghouse Subcritical Rod Worth Measurement (SRWM) methodology that was developed in cooperation with the Vogtle Reactor Engineering staff. The SRWM methodology received U. S. Nuclear Regulatory Commission (NRC) approval in August of 2005. The first application of the SPT program occurred at Vogtle Unit 2 in October of 2005. The results of the core design verification measurements obtained during the SPT program demonstrated excellent agreement with prediction, demonstrating that the predicted core characteristics were in excellent agreement with the actual operating characteristics of the core. This paper presents an overview of the SPT Program used at Vogtle Unit 2 during operating cycle 12, and a discussion of the critical path outage time savings the SPT program is capable of providing. (authors)

  7. River flood seasonality in the Northeast United States and trends in annual timing

    Science.gov (United States)

    Collins, M. J.

    2017-12-01

    The New England and Mid-Atlantic regions of the Northeast United States have experienced climate-associated increases in both the magnitude and frequency of floods. However, a detailed understanding of flood seasonality across these regions, and how flood seasonality may have changed over the instrumental record, has not been established. The annual timing of river floods reflects the flood-generating mechanisms operating in a basin and many aquatic and riparian organisms are adapted to flood seasonality, as are human uses of river channels and floodplains. Changes in flood seasonality may indicate changes in flood-generating mechanisms, and their interactions, with important implications for habitats, floodplain infrastructure, and human communities. For example, changes in spring or fall flood timing may negatively or positively affect a vulnerable life stage for a migratory fish (e.g., egg setting) depending on whether floods occur more frequently before or after the life history event. In this study I apply an objective, probabilistic method for identifying flood seasons at a monthly resolution for 90 climate-sensitive watersheds in New England and the Mid-Atlantic (Hydrologic Unit Codes 01 and 02). Historical trends in flood timing during the year are also investigated. The analyses are based on partial duration flood series that are an average of 85 years long. The seasonality of flooding in these regions, and any historical changes, are considered in the context of other ongoing or expected phenological changes in the Northeast U.S. environment that affect flood generation—e.g., the timing of leaf-off/leaf-out for deciduous plants. How these factors interact will affect whether and how flood magnitudes and frequencies change in the future and associated impacts.

  8. Timing of union formation and partner choice in immigrant societies: The United States and Germany.

    Science.gov (United States)

    Soehl, Thomas; Yahirun, Jenjira

    2011-12-01

    As Gordon noted in his 1964 treatise on assimilation, marriage across ethnic boundaries and in particular, marriage into the mainstream is a key indicator as well as a mechanism of immigrant assimilation. Since then research has investigated numerous micro- and macro level correlates of exogamy. In this paper we focus on a topic that has received less attention thus far - how the timing of marriage is associated with partner choice. We compare the United States and Germany as two countries with significant immigrant and second-generation populations but where mainstream patterns of union formation differ. In both contexts we show that unions that cross ethnic boundaries happen later in life than those that stay within. Comparing across countries we argue that in Germany differences in the timing of union formation between the second generation and the mainstream, may pose additional barriers to intermarriage that do not exist in the United States.

  9. The Measurement of Time: Children's Construction of Transitivity, Unit Iteration, and Conservation of Speed.

    Science.gov (United States)

    Long, Kathy; Kamii, Constance

    2001-01-01

    Interviews 120 children in kindergarten and grades 2, 4, and 6 with five Piagetian tasks to determine the grade level at which most have constructed transitive reasoning, unit iteration, and conservation of speed. Indicates that construction of the logic necessary to make sense of the measurement of time is generally not complete before sixth…

  10. Emergency department boarding times for patients admitted to intensive care unit: Patient and organizational influences.

    Science.gov (United States)

    Montgomery, Phyllis; Godfrey, Michelle; Mossey, Sharolyn; Conlon, Michael; Bailey, Patricia

    2014-04-01

    Critically ill patients can be subject to prolonged stays in the emergency department following receipt of an order to admit to an intensive care unit. The purpose of this study was to explore patient and organizational influences on the duration of boarding times for intensive care bound patients. This exploratory descriptive study was situated in a Canadian hospital in northern Ontario. Through a six-month retrospective review of three data sources, information was collected pertaining to 16 patient and organizational variables detailing the emergency department boarding time of adults awaiting transfer to the intensive care unit. Data analysis involved descriptive and non-parametric methods. The majority of the 122 critically ill patients boarded in the ED were male, 55 years of age or older, arriving by ground ambulance on a weekday, and had an admitting diagnosis of trauma. The median boarding time was 34 min, with a range of 0-1549 min. Patients designated as most acute, intubated, and undergoing multiple diagnostic procedures had statistically significantly shorter boarding times. The study results provide a profile that may assist clinicians in understanding the complex and site-specific interplay of variables contributing to boarding of critically ill patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Law-based arguments and messages to advocate for later school start time policies in the United States.

    Science.gov (United States)

    Lee, Clark J; Nolan, Dennis M; Lockley, Steven W; Pattison, Brent

    2017-12-01

    The increasing scientific evidence that early school start times are harmful to the health and safety of teenagers has generated much recent debate about changing school start times policies for adolescent students. Although efforts to promote and implement such changes have proliferated in the United States in recent years, they have rarely been supported by law-based arguments and messages that leverage the existing legal infrastructure regulating public education and child welfare in the United States. Furthermore, the legal bases to support or resist such changes have not been explored in detail to date. This article provides an overview of how law-based arguments and messages can be constructed and applied to advocate for later school start time policies in US public secondary schools. The legal infrastructure impacting school start time policies in the United States is briefly reviewed, including descriptions of how government regulates education, what legal obligations school officials have concerning their students' welfare, and what laws and public policies currently exist that address adolescent sleep health and safety. On the basis of this legal infrastructure, some hypothetical examples of law-based arguments and messages that could be applied to various types of advocacy activities (eg, litigation, legislative and administrative advocacy, media and public outreach) to promote later school start times are discussed. Particular consideration is given to hypothetical arguments and messages aimed at emphasizing the consistency of later school start time policies with existing child welfare law and practices, legal responsibilities of school officials and governmental authorities, and societal values and norms. Copyright © 2017 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  12. MASMA: a versatile multifunctional unit (gated window amplifier, analog memory, and height-to-time converter)

    International Nuclear Information System (INIS)

    Goursky, V.; Thenes, P.

    1969-01-01

    This multipurpose unit is designed to accomplish one of the following functions: - gated window amplifier, - Analog memory and - Amplitude-to-time converter. The first function is mainly devoted to improve the poor resolution of pulse-height analyzers with a small number of channels. The analog memory, a new function in the standard range of plug-in modules, is capable of performing a number of operations: 1) fixed delay, or variable delay dependent on an external parameter (application to the analog processing of non-coincident pulses), 2) de-randomiser to increase the efficiency of the pulse height analysis in a spectrometry experiment, 3) linear multiplexer to allow an analyser to serve as many spectrometry devices as memory elements that it possesses. Associated with a coding scaler, this unit, if used as a amplitude-to-time converter, constitutes a Wilkinson A.D.C with a capability of 10 bits (or more) and with a 100 MHz clock frequency. (authors) [fr

  13. Development of a Real-time Personal Dosimeter System and its Application to Hanul Unit-4

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kidoo; Cho, Moonhyung; Son, Jungkwon [Korea Hydro Nuclear Power Co., Seoul (Korea, Republic of)

    2013-10-15

    The main reasons to adopt the system are to minimize unnecessary exposure, to calculate one's dose faster, to provide a possible alternatives of personnel such as radiation safety manager. The KHNP's Remote radiation Monitoring System (KRMS) is characterized as integrated, less bulky, lighter comparing to existing instrument although it have multifunction of real-time dosimetry and voice communication. After laboratory test in Central Research Institute (CRI) and field test in Hanbit unit-3 and 4, KRMS was applied to main radiation works in Hanul unit-4. KHNP-CRI has developed real-time personal dose monitoring system and applied to Hanul overhaul which include steam generator replacement. It took 5 days to install the system in reactor building and the optimal location for the repeater was 3 points at 122ft and 3 points at 100ft. Owing to the optimization of repeater and high sensitivity antenna, there was no shaded area of wireless network and no loss of dose data in spite of wearing lead jacket. The average deviation of personal dose received by KRMS and existing ADR is about 2%, which tell us it matches well. The lessons learned in Hanul unit-4 are it needs simplification of operating system and it requires a function to be able to check battery level at remote area.

  14. Economic Conditions and the Divorce Rate: A Time-Series Analysis of the Postwar United States.

    Science.gov (United States)

    South, Scott J.

    1985-01-01

    Challenges the belief that the divorce rate rises during prosperity and falls during economic recessions. Time-series regression analysis of postwar United States reveals small but positive effects of unemployment on divorce rate. Stronger influences on divorce rates are changes in age structure and labor-force participation rate of women.…

  15. The timing of marriage vis-à-vis coresidence and childbearing in Europe and the United States

    NARCIS (Netherlands)

    J.A. Holland (Jennifer)

    2017-01-01

    textabstractOBJECTIVE These descriptive findings extend Holland's (2013) marriage typology by linking the timing of marriage, childbearing, and cohabitation, and apply it to a range of European countries and the United States. The meaning of marriage is organized around six ideal types: Direct

  16. Grammatical Planning Units during Real-Time Sentence Production in Speakers with Agrammatic Aphasia and Healthy Speakers

    Science.gov (United States)

    Lee, Jiyeon; Yoshida, Masaya; Thompson, Cynthia K.

    2015-01-01

    Purpose: Grammatical encoding (GE) is impaired in agrammatic aphasia; however, the nature of such deficits remains unclear. We examined grammatical planning units during real-time sentence production in speakers with agrammatic aphasia and control speakers, testing two competing models of GE. We queried whether speakers with agrammatic aphasia…

  17. Containment closure time following loss of cooling under shutdown conditions of YGN units 3 and 4

    International Nuclear Information System (INIS)

    Seul, Kwang Won; Bang, Young Seok; Kim, Se Won; Kim, Hho Jung

    1998-01-01

    The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event

  18. Quantum processes: probability fluxes, transition probabilities in unit time and vacuum vibrations

    International Nuclear Information System (INIS)

    Oleinik, V.P.; Arepjev, Ju D.

    1989-01-01

    Transition probabilities in unit time and probability fluxes are compared in studying the elementary quantum processes -the decay of a bound state under the action of time-varying and constant electric fields. It is shown that the difference between these quantities may be considerable, and so the use of transition probabilities W instead of probability fluxes Π, in calculating the particle fluxes, may lead to serious errors. The quantity W represents the rate of change with time of the population of the energy levels relating partly to the real states and partly to the virtual ones, and it cannot be directly measured in experiment. The vacuum background is shown to be continuously distorted when a perturbation acts on a system. Because of this the viewpoint of an observer on the physical properties of real particles continuously varies with time. This fact is not taken into consideration in the conventional theory of quantum transitions based on using the notion of probability amplitude. As a result, the probability amplitudes lose their physical meaning. All the physical information on quantum dynamics of a system is contained in the mean values of physical quantities. The existence of considerable differences between the quantities W and Π permits one in principle to make a choice of the correct theory of quantum transitions on the basis of experimental data. (author)

  19. Real time 3D structural and Doppler OCT imaging on graphics processing units

    Science.gov (United States)

    Sylwestrzak, Marcin; Szlag, Daniel; Szkulmowski, Maciej; Gorczyńska, Iwona; Bukowska, Danuta; Wojtkowski, Maciej; Targowski, Piotr

    2013-03-01

    In this report the application of graphics processing unit (GPU) programming for real-time 3D Fourier domain Optical Coherence Tomography (FdOCT) imaging with implementation of Doppler algorithms for visualization of the flows in capillary vessels is presented. Generally, the time of the data processing of the FdOCT data on the main processor of the computer (CPU) constitute a main limitation for real-time imaging. Employing additional algorithms, such as Doppler OCT analysis, makes this processing even more time consuming. Lately developed GPUs, which offers a very high computational power, give a solution to this problem. Taking advantages of them for massively parallel data processing, allow for real-time imaging in FdOCT. The presented software for structural and Doppler OCT allow for the whole processing with visualization of 2D data consisting of 2000 A-scans generated from 2048 pixels spectra with frame rate about 120 fps. The 3D imaging in the same mode of the volume data build of 220 × 100 A-scans is performed at a rate of about 8 frames per second. In this paper a software architecture, organization of the threads and optimization applied is shown. For illustration the screen shots recorded during real time imaging of the phantom (homogeneous water solution of Intralipid in glass capillary) and the human eye in-vivo is presented.

  20. Gender and time allocation of cohabiting and married women and men in France, Italy, and the United States.

    Science.gov (United States)

    Bianchi, Suzanne; Lesnard, Laurent; Nazio, Tiziana; Raley, Sara

    2014-07-11

    Women, who generally do more unpaid and less paid work than men, have greater incentives to stay in marriages than cohabiting unions, which generally carry fewer legal protections for individuals that wish to dissolve their relationship. The extent to which cohabitation is institutionalized, however, is a matter of policy and varies substantially by country. The gender gap in paid and unpaid work between married and cohabiting individuals should be larger in countries where cohabitation is less institutionalized and where those in cohabiting relationships have relatively fewer legal protections should the relationship dissolve, yet few studies have explored this variation. Using time diary data from France, Italy, and the United States, we assess the time men and women devote to paid and unpaid work in cohabiting and married couples. These three countries provide a useful diversity in marital regimes for examining these expectations: France, where cohabitation is most "marriage like" and where partnerships can be registered and carry legal rights; the United States, where cohabitation is common but is short-lived and unstable and where legal protections vary across states; and Italy, where cohabitation is not common and where such unions are not legally acknowledged and less socially approved than in either France or the United States. Cohabitating men's and women's time allocated to market and nonmarket work is generally more similar than married men and women. Our expectations about country differences are only partially borne out by the findings. Greater gender differences in the time allocated to market and nonmarket work are found in Italy relative to either France or the U.S.

  1. Economic and Sociological Correlates of Suicides: Multilevel Analysis of the Time Series Data in the United Kingdom.

    Science.gov (United States)

    Sun, Bruce Qiang; Zhang, Jie

    2016-03-01

    For the effects of social integration on suicides, there have been different and even contradictive conclusions. In this study, the selected economic and social risks of suicide for different age groups and genders in the United Kingdom were identified and the effects were estimated by the multilevel time series analyses. To our knowledge, there exist no previous studies that estimated a dynamic model of suicides on the time series data together with multilevel analysis and autoregressive distributed lags. The investigation indicated that unemployment rate, inflation rate, and divorce rate are all significantly and positively related to the national suicide rates in the United Kingdom from 1981 to 2011. Furthermore, the suicide rates of almost all groups above 40 years are significantly associated with the risk factors of unemployment and inflation rate, in comparison with the younger groups. © 2016 American Academy of Forensic Sciences.

  2. An extra dimension to decision-making in animals: the three-way trade-off between speed, effort per-unit-time and accuracy.

    Science.gov (United States)

    de Froment, Adrian J; Rubenstein, Daniel I; Levin, Simon A

    2014-12-01

    The standard view in biology is that all animals, from bumblebees to human beings, face a trade-off between speed and accuracy as they search for resources and mates, and attempt to avoid predators. For example, the more time a forager spends out of cover gathering information about potential food sources the more likely it is to make accurate decisions about which sources are most rewarding. However, when the cost of time spent out of cover rises (e.g. in the presence of a predator) the optimal strategy is for the forager to spend less time gathering information and to accept a corresponding decline in the accuracy of its decisions. We suggest that this familiar picture is missing a crucial dimension: the amount of effort an animal expends on gathering information in each unit of time. This is important because an animal that can respond to changing time costs by modulating its level of effort per-unit-time does not have to accept the same decrease in accuracy that an animal limited to a simple speed-accuracy trade-off must bear in the same situation. Instead, it can direct additional effort towards (i) reducing the frequency of perceptual errors in the samples it gathers or (ii) increasing the number of samples it gathers per-unit-time. Both of these have the effect of allowing it to gather more accurate information within a given period of time. We use a modified version of a canonical model of decision-making (the sequential probability ratio test) to show that this ability to substitute effort for time confers a fitness advantage in the face of changing time costs. We predict that the ability to modulate effort levels will therefore be widespread in nature, and we lay out testable predictions that could be used to detect adaptive modulation of effort levels in laboratory and field studies. Our understanding of decision-making in all species, including our own, will be improved by this more ecologically-complete picture of the three-way tradeoff between time

  3. Interferon Antagonism as a Common Virulence Factor of Hemorrhagic Fever Viruses

    Science.gov (United States)

    2008-02-01

    of hSRP1 gamma, a tissue-specific nuclear transport factor. Proc Natl Acad Sci U S A 95:582-7. 18. Prescott , J., C. Ye, G. Sen, and B. Hjelle. 2005...1Department of Microbiology 2Department of Medicine, Division of Infectious Diseases 3Emerging Pathogens Institute Mount Sinai School of Medicine, New...York, NY 10029, USA 4Department of Pathology and Immunology, Department of Molecular Microbiology 5Department of Medicine Washington University

  4. Forger les chefs de file pour appuyer l'émancipation des femmes en ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    21 juin 2016 ... Susana détient un doctorat en économie de l'éducation de l'Université de Columbia à New-York. Son expertise touche l'éducation et les politiques liés au marché du travail, l'égalité des genres et l'émancipation des femmes. Elle possède une grande expérience de travail et de consultation auprès de ...

  5. Line and Rabble: Drill, Doctrine, and Military Books in Revolutionary America

    Science.gov (United States)

    2018-04-20

    1607-1763 (New York: Macmillan, 1973); Jill Lepore, The Name of War: King Philip’s War and the Origins of American Identity (Vintage, 1999); Patrick M...Encouragement of Manufactories of Gun Powder, Musket Barrels, Musket Locks , and Salt. (New-York: Printed by John Holt, in Water-Street, near the coffee...May 1775. Rhode Island followed suite passing a law virtually identical to the Massachusetts act on 15 June 1775.27 The preface to the

  6. Containment closure time following loss of cooling under shutdown conditions of YGN units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Seul, Kwang Won; Bang, Young Seok; Kim, Se Won; Kim, Hho Jung [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    1998-12-31

    The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event. 6 refs., 7 figs., 2 tabs. (Author)

  7. United States Forest Disturbance Trends Observed Using Landsat Time Series

    Science.gov (United States)

    Masek, Jeffrey G.; Goward, Samuel N.; Kennedy, Robert E.; Cohen, Warren B.; Moisen, Gretchen G.; Schleeweis, Karen; Huang, Chengquan

    2013-01-01

    Disturbance events strongly affect the composition, structure, and function of forest ecosystems; however, existing U.S. land management inventories were not designed to monitor disturbance. To begin addressing this gap, the North American Forest Dynamics (NAFD) project has examined a geographic sample of 50 Landsat satellite image time series to assess trends in forest disturbance across the conterminous United States for 1985-2005. The geographic sample design used a probability-based scheme to encompass major forest types and maximize geographic dispersion. For each sample location disturbance was identified in the Landsat series using the Vegetation Change Tracker (VCT) algorithm. The NAFD analysis indicates that, on average, 2.77 Mha/yr of forests were disturbed annually, representing 1.09%/yr of US forestland. These satellite-based national disturbance rates estimates tend to be lower than those derived from land management inventories, reflecting both methodological and definitional differences. In particular the VCT approach used with a biennial time step has limited sensitivity to low-intensity disturbances. Unlike prior satellite studies, our biennial forest disturbance rates vary by nearly a factor of two between high and low years. High western US disturbance rates were associated with active fire years and insect activity, while variability in the east is more strongly related to harvest rates in managed forests. We note that generating a geographic sample based on representing forest type and variability may be problematic since the spatial pattern of disturbance does not necessarily correlate with forest type. We also find that the prevalence of diffuse, non-stand clearing disturbance in US forests makes the application of a biennial geographic sample problematic. Future satellite-based studies of disturbance at regional and national scales should focus on wall-to-wall analyses with annual time step for improved accuracy.

  8. Impact of mobile intensive care unit use on total ischemic time and clinical outcomes in ST-elevation myocardial infarction patients - real-world data from the Acute Coronary Syndrome Israeli Survey.

    Science.gov (United States)

    Koifman, Edward; Beigel, Roy; Iakobishvili, Zaza; Shlomo, Nir; Biton, Yitschak; Sabbag, Avi; Asher, Elad; Atar, Shaul; Gottlieb, Shmuel; Alcalai, Ronny; Zahger, Doron; Segev, Amit; Goldenberg, Ilan; Strugo, Rafael; Matetzky, Shlomi

    2017-01-01

    Ischemic time has prognostic importance in ST-elevation myocardial infarction patients. Mobile intensive care unit use can reduce components of total ischemic time by appropriate triage of ST-elevation myocardial infarction patients. Data from the Acute Coronary Survey in Israel registry 2000-2010 were analyzed to evaluate factors associated with mobile intensive care unit use and its impact on total ischemic time and patient outcomes. The study comprised 5474 ST-elevation myocardial infarction patients enrolled in the Acute Coronary Survey in Israel registry, of whom 46% ( n=2538) arrived via mobile intensive care units. There was a significant increase in rates of mobile intensive care unit utilization from 36% in 2000 to over 50% in 2010 ( pcare unit use were Killip>1 (odds ratio=1.32, pcare units benefitted from increased rates of primary reperfusion therapy (odds ratio=1.58, pcare unit benefitted from shorter median total ischemic time compared with non-mobile intensive care unit patients (175 (interquartile range 120-262) vs 195 (interquartile range 130-333) min, respectively ( pcare unit use was the most important predictor in achieving door-to-balloon time care unit group (odds ratio=0.79, 95% confidence interval (0.66-0.94), p=0.01). Among patients with ST-elevation myocardial infarction, the utilization of mobile intensive care units is associated with increased rates of primary reperfusion, a reduction in the time interval to reperfusion, and a reduction in one-year adjusted mortality.

  9. Analysis of long-time operation of micro-cogeneration unit with fuel cell

    Directory of Open Access Journals (Sweden)

    Patsch Marek

    2015-01-01

    Full Text Available Micro-cogeneration is cogeneration with small performance, with maximal electric power up to 50 kWe. On the present, there are available small micro-cogeneration units with small electric performance, about 1 kWe, which are usable also in single family houses or flats. These micro-cogeneration units operate on principle of conventional combustion engine, Stirling engine, steam engine or fuel cell. Micro-cogeneration units with fuel cells are new progressive developing type of units for single family houses. Fuel cell is electrochemical device which by oxidation-reduction reaction turn directly chemical energy of fuel to electric power, secondary products are pure water and thermal energy. The aim of paper is measuring and evaluation of operation parameters of micro-cogeneration unit with fuel cell which uses natural gas as a fuel.

  10. Dependence of the mean time to failure of a hydraulic balancing machine unit on different factors for sectional pumps of the Alrosa JSC

    Science.gov (United States)

    Ovchinnikov, N. P.; Portnyagina, V. V.; Sobakina, M. P.

    2017-12-01

    This paper presents factors that have a greater impact on the mean time to failure of a hydraulic balancing machine unit working in underground kimberlite mines of the Alrosa JSC, the hydraulic balancing machine unit being the least reliable structural elements in terms of error-free operation. In addition, a multifactor linear dependence of mean time to failure of a hydraulic balancing machine unit is shown regarding it being parts of stage sectional pumps in the underground kimberlite mines of the Alrosa JSC. In prospect, this diagram can allow us to predict the durability of the least reliable structural element of a sectional pump.

  11. Navy Irregular Warfare and Counterterrorism Operations: Background and Issues for Congress

    Science.gov (United States)

    2016-05-27

    in the Middle East, the Department of the Navy (DON) states the following in its FY2017 budget highlights book : Today the Marine Corps has a force...for example, Nicholas Schmidle, “Getting Bin Laden,” The New Yorker, August 8, 2011, accessed online August 10, 2011 at http://www.newyorker.com...Indonesia, Papua New Guinea and Malaysia ; we’ll work in the areas and help build relationships with those countries in order to provide security in

  12. Likelihood of treatment in a coronary care unit for a first-time myocardial infarction in relation to sex, country of birth and socioeconomic position in Sweden.

    Science.gov (United States)

    Yang, Dong; James, Stefan; de Faire, Ulf; Alfredsson, Lars; Jernberg, Tomas; Moradi, Tahereh

    2013-01-01

    To examine the relationship between sex, country of birth, level of education as an indicator of socioeconomic position, and the likelihood of treatment in a coronary care unit (CCU) for a first-time myocardial infarction. Nationwide register based study. Sweden. 199 906 patients (114 387 men and 85,519 women) of all ages who were admitted to hospital for first-time myocardial infarction between 2001 and 2009. Admission to a coronary care unit due to myocardial infarction. Despite the observed increasing access to coronary care units over time, the proportion of women treated in a coronary care unit was 13% less than for men. As compared with men, the multivariable adjusted odds ratio among women was 0.80 (95% confidence interval 0.77 to 0.82). This lower proportion of women treated in a CCU varied by age and year of diagnosis and country of birth. Overall, there was no evidence of a difference in likelihood of treatment in a coronary care unit between Sweden-born and foreign-born patients. As compared with patients with high education, the adjusted odds ratio among patients with a low level of education was 0.93 (95% confidence interval 0.89 to 0.96). Foreign-born and Sweden-born first-time myocardial infarction patients had equal opportunity of being treated in a coronary care unit in Sweden; this is in contrast to the situation in many other countries with large immigrant populations. However, the apparent lower rate of coronary care unit admission after first-time myocardial infarction among women and patients with low socioeconomic position warrants further investigation.

  13. Studying the development of asynchronous rolling of the rotor over the stator with the turbine unit protection systems having different response times

    Science.gov (United States)

    Shatokhin, V. F.

    2014-07-01

    The possibility to stabilize the developing asynchronous rolling of the rotor over the stator under the conditions of power unit protections coming in action with different response times is considered. Asynchronous rolling of the rotor over the stator may develop when the rotating rotor comes in contact with the stator at high amplitudes of vibration caused by an abrupt loss of rotor balancing, by forced or self-excited vibration of the rotor, and by other factors. The danger of asynchronous rolling is connected with almost instantaneous development of self-excited vibration of the rotor when it comes in contact with the stator and with the rotor vibration amplitudes and forces of interaction between the rotor and stator dangerous for the turbine unit integrity. It is assumed that the turbine unit protection systems come in action after the arrival of signal of exceeding the permissible vibration level and produce commands to disconnect the generator from the grid, and to stop the supply of working fluid into the flow path, due to which an accelerating torque ceases to act on the turbine unit shaft. The protection system response speed is determined by a certain time t = ABtime that is taken for its components to come in action from the commencement of the event (application of the signal) to closure of the stop valves. The time curves of the main rolling parameters as functions of the ABtime value are presented. It is shown that the response time of existing protection systems is not sufficient for efficiently damping the rolling phenomenon, although the use of an electrical protection system (with the response time equal to 0.40-0.45 s) may have a positive effect on stabilizing the vibration amplitudes to a certain extent during the rolling and on smoothing its dangerous consequences. The consequences of rotor rolling over the stator can be efficiently mitigated by increasing the energy losses in the rotor-stator system (especially in the stator) and by

  14. Time-dependent conversion of a methacrylate-based sealer polymerized with different light-curing units.

    Science.gov (United States)

    Beriat, Nilufer C; Ertan, Atilla; Cehreli, Zafer C; Gulsahi, Kamran

    2009-01-01

    The purpose of this study was to investigate the degree of conversion of a methacrylate-based sealer (Epiphany; Pentron Clinical Technologies, Wallingford, CT) with regard to the method of photoactivation, distance from the light-curing unit (LCU), and post-curing time. Freshly mixed Epiphany sealer was dispensed into half-pipe-shaped silicone moulds (n = 48), after which the specimens were photoactivated with one of the following LCUs from the coronal aspect: (1) quartz tungsten halogen/40 seconds and (2) light-emitting diode/20 seconds. In each specimen, the degree of conversion was measured at three different locations (coronal, middle, and apical) using Fourier transform infrared spectroscopy before and after photoactivation. The amount of conversion was approximately 50% after photoactivation and improved by approximately 10% after 15 days. Conversion of Epiphany was not affected by the type of LCU (p > 0.001) or the distance from the LCU (p > 0.001) but showed a significant increase within time (p < 0.001). These results indicate incomplete polymerization of Epiphany, despite a post-curing time of as long as 2 weeks in vitro.

  15. Practical Testing and Performance Analysis of Phasor Measurement Unit Using Real Time Digital Simulator (RTDS)

    DEFF Research Database (Denmark)

    Liu, Leo; Rather, Zakir Hussain; Stearn, Nathen

    2012-01-01

    Wide Area Measurement Systems (WAMS) and Wide Area Monitoring, Protection and Control Systems (WAMPACS) have evolved rapidly over the last two decades [1]. This fast emerging technology enables real time synchronized monitoring of power systems. Presently, WAMS are mainly used for real time...... visualisation and post event analysis of power systems. It is expected however, that through integration with traditional Supervisory Control and Data Acquisition (SCADA) systems, closed loop control applications will be possible. Phasor Measurement Units (PMUs) are fundamental components of WAMS. Large WAMS...... proposed to realize highly precise phasoreasurements. Further a comparative study based on features of PMUs from different major manufacturers is presented. The selection of optimal parameters, such as phasor format and filter length is also discussed for various applications....

  16. EMG analysis tuned for determining the timing and level of activation in different motor units.

    Science.gov (United States)

    Lee, Sabrina S M; Miara, Maria de Boef; Arnold, Allison S; Biewener, Andrew A; Wakeling, James M

    2011-08-01

    Recruitment patterns and activation dynamics of different motor units greatly influence the temporal pattern and magnitude of muscle force development, yet these features are not often considered in muscle models. The purpose of this study was to characterize the recruitment and activation dynamics of slow and fast motor units from electromyographic (EMG) recordings and twitch force profiles recorded directly from animal muscles. EMG and force data from the gastrocnemius muscles of seven goats were recorded during in vivo tendon-tap reflex and in situ nerve stimulation experiments. These experiments elicited EMG signals with significant differences in frequency content (p<0.001). The frequency content was characterized using wavelet and principal components analysis, and optimized wavelets with centre frequencies, 149.94 Hz and 323.13 Hz, were obtained. The optimized wavelets were used to calculate the EMG intensities and, with the reconstructed twitch force profiles, to derive transfer functions for slow and fast motor units that estimate the activation state of the muscle from the EMG signal. The resulting activation-deactivation time constants gave r values of 0.98-0.99 between the activation state and the force profiles. This work establishes a framework for developing improved muscle models that consider the intrinsic properties of slow and fast fibres within a mixed muscle, and that can more accurately predict muscle force output from EMG. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Multiple time scales in modeling the incidence of infections acquired in intensive care units

    Directory of Open Access Journals (Sweden)

    Martin Wolkewitz

    2016-09-01

    Full Text Available Abstract Background When patients are admitted to an intensive care unit (ICU their risk of getting an infection will be highly depend on the length of stay at-risk in the ICU. In addition, risk of infection is likely to vary over calendar time as a result of fluctuations in the prevalence of the pathogen on the ward. Hence risk of infection is expected to depend on two time scales (time in ICU and calendar time as well as competing events (discharge or death and their spatial location. The purpose of this paper is to develop and apply appropriate statistical models for the risk of ICU-acquired infection accounting for multiple time scales, competing risks and the spatial clustering of the data. Methods A multi-center data base from a Spanish surveillance network was used to study the occurrence of an infection due to Methicillin-resistant Staphylococcus aureus (MRSA. The analysis included 84,843 patient admissions between January 2006 and December 2011 from 81 ICUs. Stratified Cox models were used to study multiple time scales while accounting for spatial clustering of the data (patients within ICUs and for death or discharge as competing events for MRSA infection. Results Both time scales, time in ICU and calendar time, are highly associated with the MRSA hazard rate and cumulative risk. When using only one basic time scale, the interpretation and magnitude of several patient-individual risk factors differed. Risk factors concerning the severity of illness were more pronounced when using only calendar time. These differences disappeared when using both time scales simultaneously. Conclusions The time-dependent dynamics of infections is complex and should be studied with models allowing for multiple time scales. For patient individual risk-factors we recommend stratified Cox regression models for competing events with ICU time as the basic time scale and calendar time as a covariate. The inclusion of calendar time and stratification by ICU

  18. But science is international! Finding time and space to encourage intercultural learning in a content-driven physiology unit.

    Science.gov (United States)

    Etherington, Sarah J

    2014-06-01

    Internationalization of the curriculum is central to the strategic direction of many modern universities and has widespread benefits for student learning. However, these clear aspirations for internationalization of the curriculum have not been widely translated into more internationalized course content and teaching methods in the classroom, particularly in scientific disciplines. This study addressed one major challenge to promoting intercultural competence among undergraduate science students: finding time to scaffold such learning within the context of content-heavy, time-poor units. Small changes to enhance global and intercultural awareness were incorporated into existing assessments and teaching activities within a second-year biomedical physiology unit. Interventions were designed to start a conversation about global and intercultural perspectives on physiology, to embed the development of global awareness into the assessment and to promote cultural exchanges through peer interactions. In student surveys, 40% of domestic and 60% of international student respondents articulated specific learning about interactions in cross-cultural groups resulting from unit activities. Many students also identified specific examples of how cultural beliefs would impact on the place of biomedical physiology within the global community. In addition, staff observed more widespread benefits for student engagement and learning. It is concluded that a significant development of intercultural awareness and a more global perspective on scientific understanding can be supported among undergraduates with relatively modest, easy to implement adaptations to course content.

  19. SI units in radiation protection

    International Nuclear Information System (INIS)

    Herrmann, D.

    1976-10-01

    In the field of radiation protection all hitherto used units for activity, activity concentrations, exposure, absorbed dose, and dose rates have to be replaced by SI units during the next years. For this purpose graphs and conversion tables are given as well as recommendations on unit combinations preferentially to be used. As to the dose equivalent, it is suggested to introduce a new special unit being 100 times greater than the rem, instead of maintaining the rem or using the gray for both absorbed dose and dose equivalent. Measures and time schedule relating to the gradual transition to SI units in measuring techniques, training, and publishing et cetera are explained. (author)

  20. Overburdening: Two books on the British politics towards Southeast Asia from 1943 to 1965

    Directory of Open Access Journals (Sweden)

    Jaap Anten

    2012-05-01

    Full Text Available Review of:Peter Lowe, Contending with nationalism and communism; Britishpolicy towards Southeast Asia, 1945-65. Basingstoke and NewYork: Palgrave Macmillan, 2009, xii + 312 pp. [Global conflictand security since 1945.] ISBN 9780230524873. Price: GBP 60.00(hardback.T.O. Smith, Britain and the origin of the Vietnam War; UK policyin Indo-China, 1943-50. Basingstoke and New York: PalgraveMacmillan, 2007, xiii + 229 pp. [Global contlict and security since1945.] ISBN 9780230507050. Price: GBP 60.00 (hardback

  1. Time coder for slow neutron time-of-flight spectrometer

    International Nuclear Information System (INIS)

    Grashilin, V.A.; Ofengenden, R.G.

    1988-01-01

    Time coder for slow neutron time-of-flight spectrometer is described. The time coder is of modular structure, is performed in the CAMAC standard and operates on line with DVK-2 computer. The main coder units include supporting generator, timers, time-to-digital converter, memory unit and crate controller. Method for measuring background symmetrically to the effect is proposed for a more correct background accounting. 4 refs.; 1 fig

  2. Independent calculation of the monitor units and times of treatment in radiotherapy

    International Nuclear Information System (INIS)

    Mueller, Marcio Rogerio

    2005-01-01

    In this work, an independent verification system of calculations in radiotherapy was developed and applied, using Visual Basic TM programming language. The computational program performs calculations of monitor units and treatment time, based on the algorithm of manual calculation. The calculations executed for the independent system had initially been compared with the manual calculations performed by the medical physicists of the Institute of Radiotherapy of the Hospital das Clinicas da Universidade de Sao Paulo. In this step, the results found for more than two hundred fields studied were similar to those found in the literature; deviations larger than +- 1% were found only in five cases involving errors in manual calculation. The application of the independent system, in this stage, could have identified errors up to +- 2,4%. Based on these data, the system was validated for use in clinical routine. In a second step, calculations were compared with calculations realized by the treatment computerized planning system CadPIan TM . When, again, the results were similar to those published in other works allowing to obtain levels of acceptance of the discrepancies between the calculations executed for the independent system and the calculations developed from the planning system, separated by anatomical region, as recommended according by the recent literature. For beams of 6 MV, the levels of acceptance for deviations between the calculations of monitor units, separated by treatment region were the following; breast +- 1.7%, head and neck +2%; hypophysis +- 2.2%; pelvis +- 4 . 1% and thorax +- 1.5%. For beams of 15 MV, the level suggested for pelvis was of +- 4.5%. (author)

  3. Timing and locations of reef fish spawning off the southeastern United States.

    Directory of Open Access Journals (Sweden)

    Nicholas A Farmer

    Full Text Available Managed reef fish in the Atlantic Ocean of the southeastern United States (SEUS support a multi-billion dollar industry. There is a broad interest in locating and protecting spawning fish from harvest, to enhance productivity and reduce the potential for overfishing. We assessed spatiotemporal cues for spawning for six species from four reef fish families, using data on individual spawning condition collected by over three decades of regional fishery-independent reef fish surveys, combined with a series of predictors derived from bathymetric features. We quantified the size of spawning areas used by reef fish across many years and identified several multispecies spawning locations. We quantitatively identified cues for peak spawning and generated predictive maps for Gray Triggerfish (Balistes capriscus, White Grunt (Haemulon plumierii, Red Snapper (Lutjanus campechanus, Vermilion Snapper (Rhomboplites aurorubens, Black Sea Bass (Centropristis striata, and Scamp (Mycteroperca phenax. For example, Red Snapper peak spawning was predicted in 24.7-29.0°C water prior to the new moon at locations with high curvature in the 24-30 m depth range off northeast Florida during June and July. External validation using scientific and fishery-dependent data collections strongly supported the predictive utility of our models. We identified locations where reconfiguration or expansion of existing marine protected areas would protect spawning reef fish. We recommend increased sampling off southern Florida (south of 27° N, during winter months, and in high-relief, high current habitats to improve our understanding of timing and location of reef fish spawning off the southeastern United States.

  4. Years of Life Gained Due to Leisure-Time Physical Activity in the United States

    Science.gov (United States)

    Janssen, Ian; Carson, Valerie; Lee, I-Min; Katzmarzyk, Peter T.; Blair, Steven N.

    2013-01-01

    Background Physical inactivity is an important modifiable risk factor for non-communicable disease. The degree to which physical activity affects the life expectancy of Americans is unknown. This study estimated the potential years of life gained due to leisure-time physical activity across the adult lifespan in the United States. Methods Data from the National Health and Nutrition Examination Survey (2007–2010), National Health Interview Study mortality linkage (1990–2006), and US Life Tables (2006) were used to estimate and compare life expectancy at each age of adult life for inactive (no moderate-to-vigorous physical activity), somewhat active (some moderate-to-vigorous activity but active (≥500 metabolic equivalent min/week of moderate-to-vigorous activity) adults. Analyses were conducted in 2012. Results Somewhat active and active non-Hispanic white men had a life expectancy at age 20 that was around 2.4 years longer than the inactive men; this life expectancy advantage was 1.2 years at age 80. Similar observations were made in non-Hispanic white women, with a higher life expectancy within the active category of 3.0 years at age 20 and 1.6 years at age 80. In non-Hispanic black women, as many as 5.5 potential years of life were gained due to physical activity. Significant increases in longevity were also observed within somewhat active and active non-Hispanic black men; however, among Hispanics the years of life gained estimates were more variable and not significantly different from 0 years gained. Conclusions Leisure-time physical activity is associated with increases in longevity in the United States. PMID:23253646

  5. Risk-based assessment of the allowable outage times for the unit 1 leningrad nuclear power plant ECCS components

    International Nuclear Information System (INIS)

    Koukhar, Sergey; Vinnikov, Bronislav

    2009-01-01

    Present paper describes a method for risk - informed assessment of the Allowable Outage Times (AOTs). The AOT is the time, when components of a safety system allowed to be out of service during power operation or during shutdown operation off a plant. If the components are not restored during the time, the plant in operation must be shut down or the plant in a given shutdown mode has to go to safer shutdown mode. Application of the method is also provided for the equipment of the Unit 1 Leningrad NPP ECCS components. For solution of the problem it is necessary to carry out two series of computations using a Living PSA model, level 1. In the first series of the computations the core damage frequency (CDFb) for the base configuration of the plant is determined (there is no equipment out of service). Here the symbol 'b' means the base configuration of a plant. In the second series of the computations the core damage frequency (CDFi) for the configuration of the plant with the component (which is out of service) is calculated. That is here CDFi is determined for the failure probability of the component equal to 1.0 (component 'i' is unavailable). Then it is necessary to determine so called Risk Increase Factor (RIF) using the following ratio: RIFi = CDFi / CDFb. At last the AOT is calculated with the help of the ratio: AOTi = Tppr / RIFi, where Tppr is a period of time between two Planned Preventive Repairs (PPRs). 1. Using the risk based approach the AOTs were calculated for a set of the components of the Unit 1 Leningrad NPP ECCS components. 2. The main conclusion from the analysis is that the current deterministic AOTs for the ECCS components are conservative and should be extended. 3. The risk based extension of the AOTs for the ECCS components can prevent the Unit 1 Leningrad NPP to enter into the operating modes with increased risk. (author)

  6. Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units

    Energy Technology Data Exchange (ETDEWEB)

    Rath, N., E-mail: Nikolaus@rath.org; Levesque, J. P.; Mauel, M. E.; Navratil, G. A.; Peng, Q. [Department of Applied Physics and Applied Mathematics, Columbia University, 500 W 120th St, New York, New York 10027 (United States); Kato, S. [Department of Information Engineering, Nagoya University, Nagoya (Japan)

    2014-04-15

    Fast, digital signal processing (DSP) has many applications. Typical hardware options for performing DSP are field-programmable gate arrays (FPGAs), application-specific integrated DSP chips, or general purpose personal computer systems. This paper presents a novel DSP platform that has been developed for feedback control on the HBT-EP tokamak device. The system runs all signal processing exclusively on a Graphics Processing Unit (GPU) to achieve real-time performance with latencies below 8 μs. Signals are transferred into and out of the GPU using PCI Express peer-to-peer direct-memory-access transfers without involvement of the central processing unit or host memory. Tests were performed on the feedback control system of the HBT-EP tokamak using forty 16-bit floating point inputs and outputs each and a sampling rate of up to 250 kHz. Signals were digitized by a D-TACQ ACQ196 module, processing done on an NVIDIA GTX 580 GPU programmed in CUDA, and analog output was generated by D-TACQ AO32CPCI modules.

  7. Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units

    International Nuclear Information System (INIS)

    Rath, N.; Levesque, J. P.; Mauel, M. E.; Navratil, G. A.; Peng, Q.; Kato, S.

    2014-01-01

    Fast, digital signal processing (DSP) has many applications. Typical hardware options for performing DSP are field-programmable gate arrays (FPGAs), application-specific integrated DSP chips, or general purpose personal computer systems. This paper presents a novel DSP platform that has been developed for feedback control on the HBT-EP tokamak device. The system runs all signal processing exclusively on a Graphics Processing Unit (GPU) to achieve real-time performance with latencies below 8 μs. Signals are transferred into and out of the GPU using PCI Express peer-to-peer direct-memory-access transfers without involvement of the central processing unit or host memory. Tests were performed on the feedback control system of the HBT-EP tokamak using forty 16-bit floating point inputs and outputs each and a sampling rate of up to 250 kHz. Signals were digitized by a D-TACQ ACQ196 module, processing done on an NVIDIA GTX 580 GPU programmed in CUDA, and analog output was generated by D-TACQ AO32CPCI modules

  8. An evaluation of dose/unit area and time as key factors influencing the elicitation capacity of methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) in MCI/MI-allergic patients

    DEFF Research Database (Denmark)

    Zachariae, Claus; Lerbaek, Anne; McNamee, Pauline M

    2006-01-01

    Methylchloroisothiazolinone and methylisothiazolinone (MCI/MI) contact allergy affects 1-3% of patch-tested patients in European centres. The aim of the present study was to evaluate the importance of the factors--time and concentration (dose/per unit area)--in the elicitation capacity by means...... (2 p.p.m.) of MCI/MI/unit area of the skin for 4 weeks. After a wash-out period of at least 4 weeks, the subjects were exposed to 0.094 microg/cm2 (7.5 p.p.m.) of MCI/MI/unit area of the skin for 4 weeks. The study showed the importance of both time and exposure in the elicitation process...

  9. SUPERFUND TREATABILITY CLEARINGHOUSE: FINAL REPORT: ON-SITE INCINERATION OF SHIRCO INFRARED SYSTEMS PORTABLE PILOT TEST UNIT, TIMES BEACH, MISSOURI

    Science.gov (United States)

    During the period of July 8 - July 12, 1985, the Shirco Infrared Systems Portable Pilot Test Unit was in operation at the Times Beach Dioxin Research Facility to demonstrate the capability of Shirco's infrared technology to decontaminate silty soil laden with 2,3,7,8-tetrachlorod...

  10. Gender differences in time-use over the life-course. A comparative analysis of France, Italy, Sweden and the United States

    OpenAIRE

    Dominique Anxo; Letizia Mencarini; Ariane Paihlé; Anne Solaz; Maria Letizia Tanturri; Lennard Flood

    2011-01-01

    The main objective of this paper is to analyse how men and women in France, Italy, Sweden and United States use their time over the life cycle and the extent to which the societal and institutional contexts influence the gender division of labour. Our central hypothesis is that contextual factors play a crucial role in shaping men’s and women’s time allocation across the life course. Countries that diverge significantly in terms of welfare state regime, employment and working time systems, fa...

  11. Unit Roots in Economic and Financial Time Series: A Re-Evaluation at the Decision-Based Significance Levels

    Directory of Open Access Journals (Sweden)

    Jae H. Kim

    2017-09-01

    Full Text Available This paper re-evaluates key past results of unit root tests, emphasizing that the use of a conventional level of significance is not in general optimal due to the test having low power. The decision-based significance levels for popular unit root tests, chosen using the line of enlightened judgement under a symmetric loss function, are found to be much higher than conventional ones. We also propose simple calibration rules for the decision-based significance levels for a range of unit root tests. At the decision-based significance levels, many time series in Nelson and Plosser’s (1982 (extended data set are judged to be trend-stationary, including real income variables, employment variables and money stock. We also find that nearly all real exchange rates covered in Elliott and Pesavento’s (2006 study are stationary; and that most of the real interest rates covered in Rapach and Weber’s (2004 study are stationary. In addition, using a specific loss function, the U.S. nominal interest rate is found to be stationary under economically sensible values of relative loss and prior belief for the null hypothesis.

  12. Time Series Analysis for Forecasting Hospital Census: Application to the Neonatal Intensive Care Unit.

    Science.gov (United States)

    Capan, Muge; Hoover, Stephen; Jackson, Eric V; Paul, David; Locke, Robert

    2016-01-01

    Accurate prediction of future patient census in hospital units is essential for patient safety, health outcomes, and resource planning. Forecasting census in the Neonatal Intensive Care Unit (NICU) is particularly challenging due to limited ability to control the census and clinical trajectories. The fixed average census approach, using average census from previous year, is a forecasting alternative used in clinical practice, but has limitations due to census variations. Our objectives are to: (i) analyze the daily NICU census at a single health care facility and develop census forecasting models, (ii) explore models with and without patient data characteristics obtained at the time of admission, and (iii) evaluate accuracy of the models compared with the fixed average census approach. We used five years of retrospective daily NICU census data for model development (January 2008 - December 2012, N=1827 observations) and one year of data for validation (January - December 2013, N=365 observations). Best-fitting models of ARIMA and linear regression were applied to various 7-day prediction periods and compared using error statistics. The census showed a slightly increasing linear trend. Best fitting models included a non-seasonal model, ARIMA(1,0,0), seasonal ARIMA models, ARIMA(1,0,0)x(1,1,2)7 and ARIMA(2,1,4)x(1,1,2)14, as well as a seasonal linear regression model. Proposed forecasting models resulted on average in 36.49% improvement in forecasting accuracy compared with the fixed average census approach. Time series models provide higher prediction accuracy under different census conditions compared with the fixed average census approach. Presented methodology is easily applicable in clinical practice, can be generalized to other care settings, support short- and long-term census forecasting, and inform staff resource planning.

  13. Computational procedure of optimal inventory model involving controllable backorder rate and variable lead time with defective units

    Science.gov (United States)

    Lee, Wen-Chuan; Wu, Jong-Wuu; Tsou, Hsin-Hui; Lei, Chia-Ling

    2012-10-01

    This article considers that the number of defective units in an arrival order is a binominal random variable. We derive a modified mixture inventory model with backorders and lost sales, in which the order quantity and lead time are decision variables. In our studies, we also assume that the backorder rate is dependent on the length of lead time through the amount of shortages and let the backorder rate be a control variable. In addition, we assume that the lead time demand follows a mixture of normal distributions, and then relax the assumption about the form of the mixture of distribution functions of the lead time demand and apply the minimax distribution free procedure to solve the problem. Furthermore, we develop an algorithm procedure to obtain the optimal ordering strategy for each case. Finally, three numerical examples are also given to illustrate the results.

  14. Oxygen isotope records of Globigerina bulloides across a north-south transect in the south-western Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Khare, N.; Chaturvedi, S.K.; Saraswat, R

    , Washington, D.C). Lutjeharms, J.R.E., N.M. Walters and B.R. Allanson. 1985. Oceanic frontal systems and biologicalenhancement. p.11-21. In: Antarctic Nutrient Cycles and Food Webs. ed. by W.R. Siegfried et al., Springer-Verlag, NewYork. Matsumoto, K., J...: Ocean Sci. J.: 44(2); 2009; 117-123 OXYGEN ISOTOPE RECORDS OF GLOBIGERINA BULLOIDES ACROSS A NORTH-SOUTH TRANSECT IN THE SOUTH-WESTERN INDIAN OCEAN N. Khare 1* , S. K. Chaturvedi 2 and R. Saraswat 3 1. Ministry of Earth Sciences, Block...

  15. Massively Parallel Signal Processing using the Graphics Processing Unit for Real-Time Brain-Computer Interface Feature Extraction.

    Science.gov (United States)

    Wilson, J Adam; Williams, Justin C

    2009-01-01

    The clock speeds of modern computer processors have nearly plateaued in the past 5 years. Consequently, neural prosthetic systems that rely on processing large quantities of data in a short period of time face a bottleneck, in that it may not be possible to process all of the data recorded from an electrode array with high channel counts and bandwidth, such as electrocorticographic grids or other implantable systems. Therefore, in this study a method of using the processing capabilities of a graphics card [graphics processing unit (GPU)] was developed for real-time neural signal processing of a brain-computer interface (BCI). The NVIDIA CUDA system was used to offload processing to the GPU, which is capable of running many operations in parallel, potentially greatly increasing the speed of existing algorithms. The BCI system records many channels of data, which are processed and translated into a control signal, such as the movement of a computer cursor. This signal processing chain involves computing a matrix-matrix multiplication (i.e., a spatial filter), followed by calculating the power spectral density on every channel using an auto-regressive method, and finally classifying appropriate features for control. In this study, the first two computationally intensive steps were implemented on the GPU, and the speed was compared to both the current implementation and a central processing unit-based implementation that uses multi-threading. Significant performance gains were obtained with GPU processing: the current implementation processed 1000 channels of 250 ms in 933 ms, while the new GPU method took only 27 ms, an improvement of nearly 35 times.

  16. Real-time speckle variance swept-source optical coherence tomography using a graphics processing unit.

    Science.gov (United States)

    Lee, Kenneth K C; Mariampillai, Adrian; Yu, Joe X Z; Cadotte, David W; Wilson, Brian C; Standish, Beau A; Yang, Victor X D

    2012-07-01

    Advances in swept source laser technology continues to increase the imaging speed of swept-source optical coherence tomography (SS-OCT) systems. These fast imaging speeds are ideal for microvascular detection schemes, such as speckle variance (SV), where interframe motion can cause severe imaging artifacts and loss of vascular contrast. However, full utilization of the laser scan speed has been hindered by the computationally intensive signal processing required by SS-OCT and SV calculations. Using a commercial graphics processing unit that has been optimized for parallel data processing, we report a complete high-speed SS-OCT platform capable of real-time data acquisition, processing, display, and saving at 108,000 lines per second. Subpixel image registration of structural images was performed in real-time prior to SV calculations in order to reduce decorrelation from stationary structures induced by the bulk tissue motion. The viability of the system was successfully demonstrated in a high bulk tissue motion scenario of human fingernail root imaging where SV images (512 × 512 pixels, n = 4) were displayed at 54 frames per second.

  17. Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

    DEFF Research Database (Denmark)

    Diakos, Konstantinos; Wu, Qiuwei; Nielsen, Arne Hejde

    2014-01-01

    that is able to derive and communicate synchrophasor measurements of different parts of the power network and the development of tests, according to IEEE standards, that evaluate the performance of PMUs and PDCs. The tests are created by using a Real Time Digital Simulation (RTDS) system. The results obtained......The main focus of the electrical engineers nowadays, is to develop a smart grid that is able to monitor, evaluate and control the power system operation. The integration of Intelligent Electronic Devices (IED s) to the power network, is a strong indication of the inclination to lead the power...... network to a more reliable, secure and economic operation. The implementation of these devices though, demands the warranty of a secure operation and high-accuracy performance. This paper describes the procedure of establishing a PMU (Phasor Measurement Unit)–PDC (Phasor Data Concentrator) platform...

  18. An Algorithm of Traffic Perception of DDoS Attacks against SOA Based on Time United Conditional Entropy

    Directory of Open Access Journals (Sweden)

    Yuntao Zhao

    2016-01-01

    Full Text Available DDoS attacks can prevent legitimate users from accessing the service by consuming resource of the target nodes, whose availability of network and service is exposed to a significant threat. Therefore, DDoS traffic perception is the premise and foundation of the whole system security. In this paper the method of DDoS traffic perception for SOA network based on time united conditional entropy was proposed. According to many-to-one relationship mapping between the source IP address and destination IP addresses of DDoS attacks, traffic characteristics of services are analyzed based on conditional entropy. The algorithm is provided with perception ability of DDoS attacks on SOA services by introducing time dimension. Simulation results show that the novel method can realize DDoS traffic perception with analyzing abrupt variation of conditional entropy in time dimension.

  19. Automatic control unit for neutron transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abdel-Kawy, A.; Eid, Y.; Ashry, A.; Mostafa, M.; Hamouda, I. (Atomic Energy Establishment, Inshas (Egypt). Reactor and Neutron Physics Dept.)

    1981-01-01

    An automatic transistorized unit has been designed to control the neutron transmission measurements carried out using the time-of-flight spectrometer. The function of the automatic unit is to control the measurements of the neutron counting rate distribution transmitted through a sample at a selected channel group of the time analyzer for a certain preadjusted time period. At the end of this time, the unit removes the sample out of the neutron beam, selects a second equal channel group of the time analyzer and provides the measurement of the neutron counting rate distribution for the same time period as in the case with the sample on. Such a measuring cycle can be repeated as much as the experiment requires. At the end of these cycles the stored information can be immediately obtained through the analyzer read out unit. It is found that the time of removing the sample out of the neutron beam or returning it back does not exceed 20 seconds instead of the five minutes required in case of manual operation. The most important advantages of using such an automatic unit are saving about 20 percent of the reactor operating time avoidng unnecessary radiation exposure of the experimentalists.

  20. Exponential-time constitutive law for Palo Duro Unit 4 Salt from the J. Friemel No. 1 Well

    International Nuclear Information System (INIS)

    Senseny, P.E.; Pfeifle, T.W.; Mellegard, K.D.

    1986-07-01

    Values for the nine parameters in the exponential-time constitutive law are presented for Palo Duro Unit 4 salt. The values given for the thermal expansion and two elastic parameters are taken from previous laboratory studies. The six remaining constitutive parameters are evaluated by analyzing data from 12 triaxial compression creep tests. The specimens tested in this study are from the J. Friemel No. 1 well in Deaf County, Texas. 15 refs., 15 figs., 4 tabs

  1. Timing of the Three Mile Island Unit 2 core degradation as determined by forensic engineering

    International Nuclear Information System (INIS)

    Henrie, J.O.

    1988-01-01

    Unlike computer simulation of an event, forensic engineering is the evaluation of recorded data and damaged as well as surviving components after an event to determine progressive causes of the event. Such an evaluation of the 1979 Three Mile Island Unit 2 accident indicates that gas began accumulating in steam, generator A at 6:10, or 130 min into the accident and, therefore, fuel cladding ruptures and/or zirconium-water reactions began at that time. Zirconium oxidation/hydrogen generation rates were highest (∼70 kg of hydrogen per minute) during the core quench and collapse at 175 min. By 180 min, over 85% of the hydrogen generated by the zirconium-water reaction had been produced, and ∼400 kg of hydrogen had accumulated in the reactor coolant system. At that time, hydrogen concentrations at the steam/water interfaces in both steam generators approached 90%. By 203 min, the damaged reactor core had been reflooded and has not been uncovered since that time. Therefore, the core was completely under water at 225 min, when molten core material flowed into the lower head of the reactor vessel. 10 refs., 7 figs., 1 tab

  2. Ulrike Freitag: Indian Ocean, Migrants and State Formation in Hadhramaut. Reforming the Homeland. Ulrike Freitag & William Clarence-Smith : Hadhrami Traders, Scholars and Statesmen in the Indian Ocean, 1750s-1960s.

    Directory of Open Access Journals (Sweden)

    Jean Lambert

    2003-01-01

    Full Text Available Ulrike Freitag Indian Ocean, Migrants and State Formation in Hadhramaut. Reforming the Homeland Leyde / Boston, Brill, 2003 Ulrike Freitag & William Clarence-Smith (directeurs Hadhrami Traders, Scholars and Statesmen in the Indian Ocean, 1750s-1960s Leyde / New-York / Cologne, Brill, 1997 Le livre Indian Ocean, Migrants and State Formation in Hadhramaut nous présente l'histoire moderne du Hadramaout, du début du xixe siècle à la fin de la période britannique (1967, en parallèle avec...

  3. Time-to-code converter with selection of time intervals on duration

    International Nuclear Information System (INIS)

    Atanasov, I.Kh.; Rusanov, I.R.; )

    2001-01-01

    Identification of elementary particles on the basis of time-of-flight represents the important approach of the preliminary selection procedure. Paper describes a time-to-code converter with preliminary selection of the measured time intervals as to duration. It consists of a time-to-amplitude converter, an analog-to-digital converter, a unit of selection of time intervals as to duration, a unit of total reset and CAMAC command decoder. The time-to-code converter enables to measure time intervals with 100 ns accuracy within 0-100 ns range. Output code capacity is of 10. Selection time constitutes 50 ns [ru

  4. Containment closure time following the loss of shutdown cooling event of YGN Units 3 and 4

    International Nuclear Information System (INIS)

    Seul, Kwang Won; Bang, Young Seok; Kim, Hho Jung

    1999-01-01

    The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling (SDC) event. For the five cases of typical reactor coolant system (RCS) configurations under the worst event sequence, such as unavailable secondary cooling and no RCS inventory makeup, the thermal hydraulic analyses were performed using the RELAP5/MOS3.2 code to investigate the plant behavior following the event. The thermal hydraulic analyses include the estimation of time to boil, time to core uncovery, and time to core heat up to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. The result indicates that the containment closure is recommended to be achieved within 42 minutes after the loss of SDC for the steam generator (SG) inlet plenum manway open case or the large cold leg open case under the worst event sequence. The containment closure time is significantly dependent on the elevation and size of the opening and the SG secondary water level condition. It is also found that the containment closure needs to be initiated before the boiling time to ensure the survivability of the workers in the containment. These results will provide using information to operators to cope with the loss of SDC event. (Author). 15 refs., 3 tabs., 7 figs

  5. Evolution of Time Scales

    Science.gov (United States)

    2006-12-01

    as the fundamental unit of time in the International System of Units. It was defined as ( Metrologia , 1968) “the duration of 9 192 631 770 periods of...atomic time equivalent to the second of ET in principle. The Comité Consultatif pour la Définition de la Seconde (CCDS) of the CIPM recommended...with the definition of the second, the unit of time of the Inter- national System of Units” ( Metrologia , 1971). The CCDS (BIPM Com. Cons. Déf. Seconde

  6. Patient-care time allocation by nurse practitioners and physician assistants in the intensive care unit.

    Science.gov (United States)

    Carpenter, David L; Gregg, Sara R; Owens, Daniel S; Buchman, Timothy G; Coopersmith, Craig M

    2012-02-15

    Use of nurse practitioners and physician assistants ("affiliates") is increasing significantly in the intensive care unit (ICU). Despite this, few data exist on how affiliates allocate their time in the ICU. The purpose of this study was to understand the allocation of affiliate time into patient-care and non-patient-care activity, further dividing the time devoted to patient care into billable service and equally important but nonbillable care. We conducted a quasi experimental study in seven ICUs in an academic hospital and a hybrid academic/community hospital. After a period of self-reporting, a one-time monetary incentive of $2,500 was offered to 39 affiliates in each ICU in which every affiliate documented greater than 75% of their time devoted to patient care over a 6-month period in an effort to understand how affiliates allocated their time throughout a shift. Documentation included billable time (critical care, evaluation and management, procedures) and a new category ("zero charge time"), which facilitated record keeping of other patient-care activities. At baseline, no ICUs had documentation of 75% patient-care time by all of its affiliates. In the 6 months in which reporting was tied to a group incentive, six of seven ICUs had every affiliate document greater than 75% of their time. Individual time documentation increased from 53% to 84%. Zero-charge time accounted for an average of 21% of each shift. The most common reason was rounding, which accounted for nearly half of all zero-charge time. Sign out, chart review, and teaching were the next most common zero-charge activities. Documentation of time spent on billable activities also increased from 53% of an affiliate's shift to 63%. Time documentation was similar regardless of during which shift an affiliate worked. Approximately two thirds of an affiliate's shift is spent providing billable services to patients. Greater than 20% of each shift is spent providing equally important but not reimbursable

  7. Unit roots, nonlinearities and structural breaks

    DEFF Research Database (Denmark)

    Haldrup, Niels; Kruse, Robinson; Teräsvirta, Timo

    One of the most influential research fields in econometrics over the past decades concerns unit root testing in economic time series. In macro-economics much of the interest in the area originate from the fact that when unit roots are present, then shocks to the time series processes have...

  8. Novel web-based real-time dashboard to optimize recycling and use of red cell units at a large multi-site transfusion service.

    Science.gov (United States)

    Sharpe, Christopher; Quinn, Jason G; Watson, Stephanie; Doiron, Donald; Crocker, Bryan; Cheng, Calvino

    2014-01-01

    Effective blood inventory management reduces outdates of blood products. Multiple strategies have been employed to reduce the rate of red blood cell (RBC) unit outdate. We designed an automated real-time web-based dashboard interfaced with our laboratory information system to effectively recycle red cell units. The objective of our approach is to decrease RBC outdate rates within our transfusion service. The dashboard was deployed in August 2011 and is accessed by a shortcut that was placed on the desktops of all blood transfusion services computers in the Capital District Health Authority region. It was designed to refresh automatically every 10 min. The dashboard provides all vital information on RBC units, and implemented a color coding scheme to indicate an RBC unit's proximity to expiration. The overall RBC unit outdate rate in the 7 months period following implementation of the dashboard (September 2011-March 2012) was 1.24% (123 units outdated/9763 units received), compared to similar periods in 2010-2011 and 2009-2010: 2.03% (188/9395) and 2.81% (261/9220), respectively. The odds ratio of a RBC unit outdate postdashboard (2011-2012) compared with 2010-2011 was 0.625 (95% confidence interval: 0.497-0.786; P dashboard system is an inexpensive and novel blood inventory management system which was associated with a significant reduction in RBC unit outdate rates at our institution over a period of 7 months. This system, or components of it, could be a useful addition to existing RBC management systems at other institutions.

  9. Do time of birth, unit volume, and staff seniority affect neonatal outcome in deliveries at ≥34+0 weeks of gestation?

    Science.gov (United States)

    Reif, P; Pichler, G; Griesbacher, A; Lehner, G; Schöll, W; Lang, U; Hofmann, H; Ulrich, D

    2018-06-01

    We investigated whether time of birth, unit volume, and staff seniority affect neonatal outcome in neonates born at ≥34 +0 weeks of gestation. Population-based prospective cohort study. Ten public hospitals in the Austrian province of Styria. A total of 87 065 neonates delivered in the period 2004-2015. Based on short-term outcome data, generalised linear mixed models were used to calculate the risk for adverse and severely adverse neonatal outcomes according to time of birth, unit volume, and staff seniority. Neonatal composite adverse and severely adverse outcome measures. The odds ratio for severely adverse events during the night-time (22:01-07:29 hours) compared with the daytime (07:30-15:00 hours) was 1.35 (95% confidence interval, 95% CI 1.13-1.61). There were no significant differences in neonatal outcome comparing weekdays and weekends, and comparing office hours and shifts. Units with 500-1000 deliveries per year had the lowest risk for adverse events. Adverse and severely adverse neonatal outcomes were least common for midwife-guided deliveries, and became more frequent with the level of experience of the doctors attending the delivery. With increasing pregnancy risks, senior staff attending delivery and delivering in a tertiary centre reduce the odds ratio for adverse events. Different times of delivery were associated with increased adverse neonatal outcomes. The management of uncomplicated deliveries by less experienced staff showed no negative impact on perinatal outcome. In contrast, riskier pregnancies delivered by senior staff in a tertiary centre favour a better outcome. Achieving a better balance in the total number of labour ward staff during the day and the night appears to be a greater priority than increasing the continuous presence of senior obstetrical staff on the labour ward during the out-of-hours period. Deliveries during night time lead to a greater number of neonates experiencing severely adverse events. © 2017 Royal College of

  10. Real-time computation of parameter fitting and image reconstruction using graphical processing units

    Science.gov (United States)

    Locans, Uldis; Adelmann, Andreas; Suter, Andreas; Fischer, Jannis; Lustermann, Werner; Dissertori, Günther; Wang, Qiulin

    2017-06-01

    In recent years graphical processing units (GPUs) have become a powerful tool in scientific computing. Their potential to speed up highly parallel applications brings the power of high performance computing to a wider range of users. However, programming these devices and integrating their use in existing applications is still a challenging task. In this paper we examined the potential of GPUs for two different applications. The first application, created at Paul Scherrer Institut (PSI), is used for parameter fitting during data analysis of μSR (muon spin rotation, relaxation and resonance) experiments. The second application, developed at ETH, is used for PET (Positron Emission Tomography) image reconstruction and analysis. Applications currently in use were examined to identify parts of the algorithms in need of optimization. Efficient GPU kernels were created in order to allow applications to use a GPU, to speed up the previously identified parts. Benchmarking tests were performed in order to measure the achieved speedup. During this work, we focused on single GPU systems to show that real time data analysis of these problems can be achieved without the need for large computing clusters. The results show that the currently used application for parameter fitting, which uses OpenMP to parallelize calculations over multiple CPU cores, can be accelerated around 40 times through the use of a GPU. The speedup may vary depending on the size and complexity of the problem. For PET image analysis, the obtained speedups of the GPU version were more than × 40 larger compared to a single core CPU implementation. The achieved results show that it is possible to improve the execution time by orders of magnitude.

  11. Novel web-based real-time dashboard to optimize recycling and use of red cell units at a large multi-site transfusion service

    Directory of Open Access Journals (Sweden)

    Christopher Sharpe

    2014-01-01

    Full Text Available Background: Effective blood inventory management reduces outdates of blood products. Multiple strategies have been employed to reduce the rate of red blood cell (RBC unit outdate. We designed an automated real-time web-based dashboard interfaced with our laboratory information system to effectively recycle red cell units. The objective of our approach is to decrease RBC outdate rates within our transfusion service. Methods: The dashboard was deployed in August 2011 and is accessed by a shortcut that was placed on the desktops of all blood transfusion services computers in the Capital District Health Authority region. It was designed to refresh automatically every 10 min. The dashboard provides all vital information on RBC units, and implemented a color coding scheme to indicate an RBC unit′s proximity to expiration. Results: The overall RBC unit outdate rate in the 7 months period following implementation of the dashboard (September 2011-March 2012 was 1.24% (123 units outdated/9763 units received, compared to similar periods in 2010-2011 and 2009-2010: 2.03% (188/9395 and 2.81% (261/9220, respectively. The odds ratio of a RBC unit outdate postdashboard (2011-2012 compared with 2010-2011 was 0.625 (95% confidence interval: 0.497-0.786; P < 0.0001. Conclusion: Our dashboard system is an inexpensive and novel blood inventory management system which was associated with a significant reduction in RBC unit outdate rates at our institution over a period of 7 months. This system, or components of it, could be a useful addition to existing RBC management systems at other institutions.

  12. Self-organization comprehensive real-time state evaluation model for oil pump unit on the basis of operating condition classification and recognition

    Science.gov (United States)

    Liang, Wei; Yu, Xuchao; Zhang, Laibin; Lu, Wenqing

    2018-05-01

    In oil transmission station, the operating condition (OC) of an oil pump unit sometimes switches accordingly, which will lead to changes in operating parameters. If not taking the switching of OCs into consideration while performing a state evaluation on the pump unit, the accuracy of evaluation would be largely influenced. Hence, in this paper, a self-organization Comprehensive Real-Time State Evaluation Model (self-organization CRTSEM) is proposed based on OC classification and recognition. However, the underlying model CRTSEM is built through incorporating the advantages of Gaussian Mixture Model (GMM) and Fuzzy Comprehensive Evaluation Model (FCEM) first. That is to say, independent state models are established for every state characteristic parameter according to their distribution types (i.e. the Gaussian distribution and logistic regression distribution). Meanwhile, Analytic Hierarchy Process (AHP) is utilized to calculate the weights of state characteristic parameters. Then, the OC classification is determined by the types of oil delivery tasks, and CRTSEMs of different standard OCs are built to constitute the CRTSEM matrix. On the other side, the OC recognition is realized by a self-organization model that is established on the basis of Back Propagation (BP) model. After the self-organization CRTSEM is derived through integration, real-time monitoring data can be inputted for OC recognition. At the end, the current state of the pump unit can be evaluated by using the right CRTSEM. The case study manifests that the proposed self-organization CRTSEM can provide reasonable and accurate state evaluation results for the pump unit. Besides, the assumption that the switching of OCs will influence the results of state evaluation is also verified.

  13. Unit-of-Use Versus Traditional Bulk Packaging

    Directory of Open Access Journals (Sweden)

    Tiffany So

    2012-01-01

    Full Text Available Background: The choice between unit-of-use versus traditional bulk packaging in the US has long been a continuous debate for drug manufacturers and pharmacies in order to have the most efficient and safest practices. Understanding the benefits of using unit-of-use packaging over bulk packaging by US drug manufacturers in terms of workflow efficiency, economical costs and medication safety in the pharmacy is sometimes challenging.Methods: A time-saving study comparing the time saved using unit-of-use packaging versus bulk packaging, was examined. Prices between unit-of-use versus bulk packages were compared by using the Red Book: Pharmacy’s Fundamental Reference. Other articles were reviewed on the topics of counterfeiting, safe labeling, and implementation of unit-of-use packaging. Lastly, a cost-saving study was reviewed showing how medication adherence, due to improved packaging, could be cost-effective for patients.Results: When examining time, costs, medication adherence, and counterfeiting arguments, unit-of-use packaging proved to be beneficial for patients in all these terms.

  14. Unit-of-Use Versus Traditional Bulk Packaging

    Directory of Open Access Journals (Sweden)

    Tiffany So

    2012-01-01

    Full Text Available Background: The choice between unit-of-use versus traditional bulk packaging in the US has long been a continuous debate for drug manufacturers and pharmacies in order to have the most efficient and safest practices. Understanding the benefits of using unit-of-use packaging over bulk packaging by US drug manufacturers in terms of workflow efficiency, economical costs and medication safety in the pharmacy is sometimes challenging. Methods: A time-saving study comparing the time saved using unit-of-use packaging versus bulk packaging, was examined. Prices between unit-of-use versus bulk packages were compared by using the Red Book: Pharmacy's Fundamental Reference. Other articles were reviewed on the topics of counterfeiting, safe labeling, and implementation of unit-of-use packaging. Lastly, a cost-saving study was reviewed showing how medication adherence, due to improved packaging, could be cost-effective for patients. Results: When examining time, costs, medication adherence, and counterfeiting arguments, unit-of-use packaging proved to be beneficial for patients in all these terms.   Type: Student Project

  15. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    International Nuclear Information System (INIS)

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2017-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  16. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    Energy Technology Data Exchange (ETDEWEB)

    Baldaconi, Ricardo H., E-mail: ricardohovacker@hotmail.com [Escola Senai Roberto Simonsen, Educação e Tecnologia, Sao Paulo, SP (Brazil); Costa, Fabio E. da, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  17. Time-Predictable Virtual Memory

    DEFF Research Database (Denmark)

    Puffitsch, Wolfgang; Schoeberl, Martin

    2016-01-01

    Virtual memory is an important feature of modern computer architectures. For hard real-time systems, memory protection is a particularly interesting feature of virtual memory. However, current memory management units are not designed for time-predictability and therefore cannot be used...... in such systems. This paper investigates the requirements on virtual memory from the perspective of hard real-time systems and presents the design of a time-predictable memory management unit. Our evaluation shows that the proposed design can be implemented efficiently. The design allows address translation...... and address range checking in constant time of two clock cycles on a cache miss. This constant time is in strong contrast to the possible cost of a miss in a translation look-aside buffer in traditional virtual memory organizations. Compared to a platform without a memory management unit, these two additional...

  18. The Scales of Time, Length, Mass, Energy, and Other Fundamental Physical Quantities in the Atomic World and the Use of Atomic Units in Quantum Mechanical Calculations

    Science.gov (United States)

    Teo, Boon K.; Li, Wai-Kee

    2011-01-01

    This article is divided into two parts. In the first part, the atomic unit (au) system is introduced and the scales of time, space (length), and speed, as well as those of mass and energy, in the atomic world are discussed. In the second part, the utility of atomic units in quantum mechanical and spectroscopic calculations is illustrated with…

  19. Study on efficiency of time computation in x-ray imaging simulation base on Monte Carlo algorithm using graphics processing unit

    International Nuclear Information System (INIS)

    Setiani, Tia Dwi; Suprijadi; Haryanto, Freddy

    2016-01-01

    Monte Carlo (MC) is one of the powerful techniques for simulation in x-ray imaging. MC method can simulate the radiation transport within matter with high accuracy and provides a natural way to simulate radiation transport in complex systems. One of the codes based on MC algorithm that are widely used for radiographic images simulation is MC-GPU, a codes developed by Andrea Basal. This study was aimed to investigate the time computation of x-ray imaging simulation in GPU (Graphics Processing Unit) compared to a standard CPU (Central Processing Unit). Furthermore, the effect of physical parameters to the quality of radiographic images and the comparison of image quality resulted from simulation in the GPU and CPU are evaluated in this paper. The simulations were run in CPU which was simulated in serial condition, and in two GPU with 384 cores and 2304 cores. In simulation using GPU, each cores calculates one photon, so, a large number of photon were calculated simultaneously. Results show that the time simulations on GPU were significantly accelerated compared to CPU. The simulations on the 2304 core of GPU were performed about 64 -114 times faster than on CPU, while the simulation on the 384 core of GPU were performed about 20 – 31 times faster than in a single core of CPU. Another result shows that optimum quality of images from the simulation was gained at the history start from 10"8 and the energy from 60 Kev to 90 Kev. Analyzed by statistical approach, the quality of GPU and CPU images are relatively the same.

  20. Study on efficiency of time computation in x-ray imaging simulation base on Monte Carlo algorithm using graphics processing unit

    Energy Technology Data Exchange (ETDEWEB)

    Setiani, Tia Dwi, E-mail: tiadwisetiani@gmail.com [Computational Science, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung Jalan Ganesha 10 Bandung, 40132 (Indonesia); Suprijadi [Computational Science, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung Jalan Ganesha 10 Bandung, 40132 (Indonesia); Nuclear Physics and Biophysics Reaserch Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung Jalan Ganesha 10 Bandung, 40132 (Indonesia); Haryanto, Freddy [Nuclear Physics and Biophysics Reaserch Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung Jalan Ganesha 10 Bandung, 40132 (Indonesia)

    2016-03-11

    Monte Carlo (MC) is one of the powerful techniques for simulation in x-ray imaging. MC method can simulate the radiation transport within matter with high accuracy and provides a natural way to simulate radiation transport in complex systems. One of the codes based on MC algorithm that are widely used for radiographic images simulation is MC-GPU, a codes developed by Andrea Basal. This study was aimed to investigate the time computation of x-ray imaging simulation in GPU (Graphics Processing Unit) compared to a standard CPU (Central Processing Unit). Furthermore, the effect of physical parameters to the quality of radiographic images and the comparison of image quality resulted from simulation in the GPU and CPU are evaluated in this paper. The simulations were run in CPU which was simulated in serial condition, and in two GPU with 384 cores and 2304 cores. In simulation using GPU, each cores calculates one photon, so, a large number of photon were calculated simultaneously. Results show that the time simulations on GPU were significantly accelerated compared to CPU. The simulations on the 2304 core of GPU were performed about 64 -114 times faster than on CPU, while the simulation on the 384 core of GPU were performed about 20 – 31 times faster than in a single core of CPU. Another result shows that optimum quality of images from the simulation was gained at the history start from 10{sup 8} and the energy from 60 Kev to 90 Kev. Analyzed by statistical approach, the quality of GPU and CPU images are relatively the same.

  1. Science Unit Plans. PACE '94.

    Science.gov (United States)

    Schoon, Kenneth J., Ed.; Wiles, Clyde A., Ed.

    This booklet contains mathematics unit plans for Biology, Chemistry, and Physical Science developed by PACE (Promoting Academic Excellence In Mathematics, Science & Technology for Workers of the 21st Century). Each unit plan contains suggested timing, objectives, skills to be acquired, workplace relationships, learning activities with suggested…

  2. Microbial heterotrophic metabolic rates constrain the microbial carbon pump

    Digital Repository Service at National Institute of Oceanography (India)

    Robinson, C.; Ramaiah, N.

    (2008). 10. P.A. del Giorgio, J. J. Cole, in MicrobialEcologyoftheOceans D. L. Kirchman Ed. (JohnWiley & Sons, Inc. NewYork ed. 1. 2000),pp. 289–325. 11. A. B. Burd etal., DeepSeaRes.II 57, 1557 (2010). 12. S. Martinez-García, E. Fernández, M.... R.A. Straza, D. L. Kirchman, Aquat.Microb.Ecol. 62, 267(2011). 16. O. Hoegh-Guldberg, J. F. Bruno, Science 328,1523 (2010). 17. J. Piontek, M. Lunau, N. Handel, C. Borchard, M.Wurst,A. Engel, Biogeosciences 7, 1615 (2010). 18. J. K.Apple, P.A. del...

  3. Provision of bereavement care in neonatal units in the United Kingdom.

    Science.gov (United States)

    Robertson, Meredith J P; Aldridge, Anne; Curley, Anna E

    2011-05-01

    To establish what bereavement care services are available in neonatal units in the United Kingdom and to establish the availability to staff (doctors, nurses, and chaplains) of bereavement education, training, communication, and multicultural support. For families who lose a baby in the neonatal period, the support they receive from hospital staff can be pivotal in their ability to cope with their grief. Hospital staff are not always trained to provide this support. Limited evidence is available regarding hospital-based bereavement care in neonatology or its impact on outcome. Questionnaire survey of selected doctors, nurses, and chaplains in 200 neonatal units in the United Kingdom. We had responses from 100% of neonatal units surveyed. Of 600 individuals, 320 responded; 11% of doctors had never received any formal training in bereavement care, compared with 0.8% of nurses and 1.2% and chaplains. In addition, 31% of respondents thought the training they received was inadequate. Knowledge of grief theorists was poor. Up to 99% of units were helping parents create memories through photographs or handprints. Parents were uniformly given the chance to be with their baby at the time of death (99% overall). Siblings were encouraged to be present 71% of the time; 75% of respondents felt that information about the needs of different faith groups was available. Formal psychological support was offered to 45% of families after bereavement. Studies have shown that parents value clear communication, education about grieving, and demonstrated emotional support by staff. Our study has shown that there are deficiencies in staff training and education in this area. Educators must promote the inclusion of content on bereavement/end-of-life care. Additional education on cultural issues would be helpful. Managing the bereavement process well to minimize morbidity for families and healthcare providers is an important challenge for the future.

  4. Definitions of Quantities and Units.

    Science.gov (United States)

    Spurgin, C. B.

    1983-01-01

    Compares various methods of defining derived quantities, arguing for a definitional formula using base or fundamental units in a word equation, or symbol-equations with the symbols explained. Suggests that fundamental units be defined operationally or left regarded as intuitive as in the case of length and time. (JM)

  5. Testing for seasonal unit roots in monthly panels of time series

    NARCIS (Netherlands)

    R.M. Kunst (Robert); Ph.H.B.F. Franses (Philip Hans)

    2009-01-01

    textabstractWe consider the problem of testing for seasonal unit roots in monthly panel data. To this aim, we generalize the quarterly CHEGY test to the monthly case. This parametric test is contrasted with a new nonparametric test, which is the panel counterpart to the univariate RURS test that

  6. Operable Unit Boundaries

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset consists of operable unit data from multiple Superfund sites in U.S. EPA Region 8. These data were acquired from multiple sources at different times and...

  7. Real-time track-less Cherenkov ring fitting trigger system based on Graphics Processing Units

    Science.gov (United States)

    Ammendola, R.; Biagioni, A.; Chiozzi, S.; Cretaro, P.; Cotta Ramusino, A.; Di Lorenzo, S.; Fantechi, R.; Fiorini, M.; Frezza, O.; Gianoli, A.; Lamanna, G.; Lo Cicero, F.; Lonardo, A.; Martinelli, M.; Neri, I.; Paolucci, P. S.; Pastorelli, E.; Piandani, R.; Piccini, M.; Pontisso, L.; Rossetti, D.; Simula, F.; Sozzi, M.; Vicini, P.

    2017-12-01

    The parallel computing power of commercial Graphics Processing Units (GPUs) is exploited to perform real-time ring fitting at the lowest trigger level using information coming from the Ring Imaging Cherenkov (RICH) detector of the NA62 experiment at CERN. To this purpose, direct GPU communication with a custom FPGA-based board has been used to reduce the data transmission latency. The GPU-based trigger system is currently integrated in the experimental setup of the RICH detector of the NA62 experiment, in order to reconstruct ring-shaped hit patterns. The ring-fitting algorithm running on GPU is fed with raw RICH data only, with no information coming from other detectors, and is able to provide more complex trigger primitives with respect to the simple photodetector hit multiplicity, resulting in a higher selection efficiency. The performance of the system for multi-ring Cherenkov online reconstruction obtained during the NA62 physics run is presented.

  8. The Carnegie Unit: Past, Present, and Future

    Science.gov (United States)

    Silva, Elena; White, Taylor

    2015-01-01

    For more than a century, the Carnegie Unit has been the central organizing feature of American education. Translated into the "credit hour" in higher education (roughly, one hour of class time per week in a 14-16 week semester), this time-based unit is embedded in nearly every aspect of the system, from faculty-workload and…

  9. Siblings and children's time use in the United States

    Directory of Open Access Journals (Sweden)

    Rachel Dunifon

    2017-11-01

    Full Text Available Background: Eighty-two percent of children under age 18 live with at least one sibling, and the sibling relationship is typically the longest-lasting family relationship in an individual's life. Nevertheless, siblings remain understudied in the family demography literature. Objective: We ask how having a sibling structures children's time spent with others and in specific activities, and how children's time and activities with siblings vary by social class, gender, and age. Methods: We use time diary data from the US Panel Study of Income Dynamics' Child Development Supplement (PSID-CDS, comparing the time use of children with and without siblings and presenting regression-adjusted descriptive statistics on patterns among those with siblings. Results: Children with siblings spend about half of their discretionary time engaged with siblings. They spend less time alone with parents and more time in unstructured play than those without siblings. Brothers and more closely spaced siblings spend more time together and more time in unstructured play. For example, boys with at least one brother spend five more hours per week with their siblings and over three more hours per week in unstructured play than boys with no brothers. Conclusions: The presence and characteristics of siblings shape children's time use in ways that may have implications for child development. Contribution: This is the first study to use children's time diary data to examine how the presence and characteristics of siblings structure ways in which children spend their time. This contributes to our broader understanding of sibling relationships and family dynamics.

  10. Inching toward incrementalism: federalism, devolution, and health policy in the United States and the United Kingdom.

    Science.gov (United States)

    Sparer, Michael S; France, George; Clinton, Chelsea

    2011-02-01

    In the United States, the recently enacted Patient Protection and Affordable Care Act of 2010 envisions a significant increase in federal oversight over the nation's health care system. At the same time, however, the legislation requires the states to play key roles in every aspect of the reform agenda (such as expanding Medicaid programs, creating insurance exchanges, and working with providers on delivery system reforms). The complicated intergovernmental partnerships that govern the nation's fragmented and decentralized system are likely to continue, albeit with greater federal oversight and control. But what about intergovernmental relations in the United Kingdom? What impact did the formal devolution of power in 1999 to Scotland, Wales, and Northern Ireland have on health policy in those nations, and in the United Kingdom more generally? Has devolution begun a political process in which health policy in the United Kingdom will, over time, become increasingly decentralized and fragmented, or will this "state of unions" retain its long-standing reputation as perhaps the most centralized of the European nations? In this article, we explore the federalist and intergovernmental implications of recent reforms in the United States and the United Kingdom, and we put forward the argument that political fragmentation (long-standing in the United States and just emerging in the United Kingdom) produces new intergovernmental partnerships that, in turn, produce incremental growth in overall government involvement in the health care arena. This is the impact of what can be called catalytic federalism.

  11. The analysis in real time, during the pre-commissioning period, of the overall plant control system of the CANDU NPP unit

    International Nuclear Information System (INIS)

    Tapu, C.; Irimia, M.

    1994-01-01

    The physical processes in the CANDU NPP are controlled by a computer system which, based on the associated package of programmes, performs both the monitoring function at the level of the operational area, and the digital regulation function of the technological systems within the NPP. For an optimal operation of the NPP, in dynamic as well as in stationary regime, the correlation of the direct digital control of the technological systems is very important for the NPP's overall digital control system. Taking into account the fact that during the pre-commissioning period of a CANDU unit it is necessary to test in dynamic regime the performance of the overall digital control function of the NPP, a system of verification and testing in real time was developed, by connecting a micro simulator of the physical process in the NPP to the actual computer system of the unit. The paper presents the methods and techniques used, as well as the results of the tests for various operational modes, which highlight the functioning of the digital control system of the CANDU NPP unit. (Author)

  12. Substance Use Disorders and Poverty as Prospective Predictors of Adult First-Time Suicide Ideation or Attempt in the United States.

    Science.gov (United States)

    Thompson, Ronald G; Alonzo, Dana; Hu, Mei-Chen; Hasin, Deborah S

    2017-04-01

    This study examined whether substance use disorders (SUD) and poverty predicted first-time suicide ideation or attempt in United States national data. Respondents without prior histories of suicide ideation or attempt at Wave 1 of the NESARC (N = 31,568) were analyzed to determine the main and interactive effects of SUD and poverty on first-time suicide ideation or attempt by Wave 2, 3 years later. Adjusted for controls, poverty (AOR = 1.35, CI = 1.05-1.73) and drug use disorders (AOR = 2.10, CI = 1.07-4.14) independently increased risk for first-time suicide ideation or attempt at Wave 2. SUD and poverty did not interact to differentially increase risk for first-time suicide ideation or attempt, prior to or after adjustment for controls. This study reinforces the importance of SUD and poverty in the risk for first-time suicide ideation or attempt. Public health efforts should target messages to drug users and the impoverished that highlight their increased risk for first-time suicide.

  13. Imagine There's No Carnegie Unit

    Science.gov (United States)

    Klevgaard, Janine

    2013-01-01

    This article describes how the Alberta Education High School Flexibility Enhancement Pilot Project allowed 16 high schools in Alberta, Canada, to remove the restrictions of the Carnegie unit, the seat time per credit requirement that has been widely used since 1906. The two purposes of the project were to determine whether the Carnegie unit should…

  14. Semi-automatic film processing unit

    International Nuclear Information System (INIS)

    Mohamad Annuar Assadat Husain; Abdul Aziz Bin Ramli; Mohd Khalid Matori

    2005-01-01

    The design concept applied in the development of an semi-automatic film processing unit needs creativity and user support in channelling the required information to select materials and operation system that suit the design produced. Low cost and efficient operation are the challenges that need to be faced abreast with the fast technology advancement. In producing this processing unit, there are few elements which need to be considered in order to produce high quality image. Consistent movement and correct time coordination for developing and drying are a few elements which need to be controlled. Other elements which need serious attentions are temperature, liquid density and the amount of time for the chemical liquids to react. Subsequent chemical reaction that take place will cause the liquid chemical to age and this will adversely affect the quality of image produced. This unit is also equipped with liquid chemical drainage system and disposal chemical tank. This unit would be useful in GP clinics especially in rural area which practice manual system for developing and require low operational cost. (Author)

  15. 76 FR 66845 - United Nations Day, 2011

    Science.gov (United States)

    2011-10-27

    ... become ever more intertwined, the leadership, staff, and member states of the United Nations continue to... a time of dramatic political transformation, the United Nations can embrace democratic movements and...

  16. School Start Times for Middle School and High School Students - United States, 2011-12 School Year.

    Science.gov (United States)

    Wheaton, Anne G; Ferro, Gabrielle A; Croft, Janet B

    2015-08-07

    Adolescents who do not get enough sleep are more likely to be overweight; not engage in daily physical activity; suffer from depressive symptoms; engage in unhealthy risk behaviors such as drinking, smoking tobacco, and using illicit drugs; and perform poorly in school. However, insufficient sleep is common among high school students, with less than one third of U.S. high school students sleeping at least 8 hours on school nights. In a policy statement published in 2014, the American Academy of Pediatrics (AAP) urged middle and high schools to modify start times as a means to enable students to get adequate sleep and improve their health, safety, academic performance, and quality of life. AAP recommended that "middle and high schools should aim for a starting time of no earlier than 8:30 a.m.". To assess state-specific distributions of public middle and high school start times and establish a pre-recommendation baseline, CDC and the U.S. Department of Education analyzed data from the 2011-12 Schools and Staffing Survey (SASS). Among an estimated 39,700 public middle, high, and combined schools* in the United States, the average start time was 8:03 a.m. Overall, only 17.7% of these public schools started school at 8:30 a.m. or later. The percentage of schools with 8:30 a.m. or later start times varied greatly by state, ranging from 0% in Hawaii, Mississippi, and Wyoming to more than three quarters of schools in Alaska (76.8%) and North Dakota (78.5%). A school system start time policy of 8:30 a.m. or later provides teenage students the opportunity to achieve the 8.5-9.5 hours of sleep recommended by AAP and the 8-10 hours recommended by the National Sleep Foundation.

  17. METRIC context unit architecture

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, R.O.

    1988-01-01

    METRIC is an architecture for a simple but powerful Reduced Instruction Set Computer (RISC). Its speed comes from the simultaneous processing of several instruction streams, with instructions from the various streams being dispatched into METRIC's execution pipeline as they become available for execution. The pipeline is thus kept full, with a mix of instructions for several contexts in execution at the same time. True parallel programming is supported within a single execution unit, the METRIC Context Unit. METRIC's architecture provides for expansion through the addition of multiple Context Units and of specialized Functional Units. The architecture thus spans a range of size and performance from a single-chip microcomputer up through large and powerful multiprocessors. This research concentrates on the specification of the METRIC Context Unit at the architectural level. Performance tradeoffs made during METRIC's design are discussed, and projections of METRIC's performance are made based on simulation studies.

  18. Review of registration requirements for new part-time doctors in New Zealand, Australia, the United Kingdom, Ireland and Canada.

    Science.gov (United States)

    Leitch, Sharon; Dovey, Susan M

    2010-12-01

    By the time medical students graduate many wish to work part-time while accommodating other lifestyle interests. To review flexibility of medical registration requirements for provisional registrants in New Zealand, Australia, the United Kingdom, Ireland and Canada. Internet-based review of registration bodies of each country, and each state or province in Australia and Canada, supplemented by emails and phone calls seeking clarification of missing or obscure information. Data from 20 regions were examined. Many similarities were found between study countries in their approaches to the registration of new doctors, although there are some regional differences. Most regions (65%) have a provisional registration period of one year. Extending this period was possible in 91% of regions. Part-time options were possible in 75% of regions. All regions required trainees to work in approved practice settings. Only the UK provided comprehensive documentation of their requirements in an accessible format and clearly explaining the options for part-time work. Australia appeared to be more flexible than other countries with respect to part- and full-time work requirements. All countries need to examine their registration requirements to introduce more flexibility wherever possible, as a strategy for addressing workforce shortages.

  19. Expanding the usefulness of unit supply cost

    International Nuclear Information System (INIS)

    McKenzie, M.B.; Petr, K.

    1992-01-01

    Unit supply cost is a widely used tool in the energy business for providing a one number-unit cost description. For example, controllable costs such as finding costs, development costs and operating costs have traditionally been described in an average cost per unit of reserves format for the oil and gas industry, however using this approach on more specific applications is not always informative. Projects with widely varying controllable parameters can still yield the same unit cost, making comparisons difficult. The application of unit supply cost can be readily expanded by adding a new unit cost component termed cost of capital. This element introduces the impacts of timing and return on investment into the supply cost determination through discounting annual costs. The cost of capital component adds the ability to represent a project's unique characteristics, particularly reserves' depletion rate and the timing or phasing of development. Introducing the cost of capital element into the supply cost analysis provides additional information and improves the likelihood of drawing correct conclusions when comparing and ranking projects. 4 figs., 6 tabs

  20. Performance comparison of next generation controller and MPC in real time for a SISO process with low cost DAQ unit

    Directory of Open Access Journals (Sweden)

    V. Bagyaveereswaran

    2016-09-01

    Full Text Available In this paper, a brief overview of real time implementation of next generation Robust, Tracking, Disturbance rejecting, Aggressive (RTDA controller and Model Predictive Control (MPC is provided. The control algorithm is implemented through MATLAB. The plant model used in controller design is obtained using system identification tool and integral response method. The controller model is developed in Simulink using jMPC tool, which will be executed in real time. The outputs obtained are tested for various constraint values to obtain the desirable results. The implementation of Hardware in Loop is done by interfacing it with MATLAB using Arduino as data acquisition unit. The performance of RTDA is compared with those of MPC and Proportional Integral controller.

  1. The role of the intensive care unit in real-time surveillance of emerging pandemics: the Italian GiViTI experience.

    Science.gov (United States)

    Bertolini, G; Nattino, G; Langer, M; Tavola, M; Crespi, D; Mondini, M; Rossi, C; Previtali, C; Marshall, J; Poole, D

    2016-01-01

    The prompt availability of reliable epidemiological information on emerging pandemics is crucial for public health policy-makers. Early in 2013, a possible new H1N1 epidemic notified by an intensive care unit (ICU) to GiViTI, the Italian ICU network, prompted the re-activation of the real-time monitoring system developed during the 2009-2010 pandemic. Based on data from 216 ICUs, we were able to detect and monitor an outbreak of severe H1N1 infection, and to compare the situation with previous years. The timely and correct assessment of the severity of an epidemic can be obtained by investigating ICU admissions, especially when historical comparisons can be made.

  2. Use of Internet Search Data to Monitor Rotavirus Vaccine Impact in the United States, United Kingdom, and Mexico.

    Science.gov (United States)

    Shah, Minesh P; Lopman, Benjamin A; Tate, Jacqueline E; Harris, John; Esparza-Aguilar, Marcelino; Sanchez-Uribe, Edgar; Richardson, Vesta; Steiner, Claudia A; Parashar, Umesh D

    2018-02-19

    Previous studies have found a strong correlation between internet search and public health surveillance data. Less is known about how search data respond to public health interventions, such as vaccination, and the consistency of responses in different countries. In this study, we aimed to study the correlation between internet searches for "rotavirus" and rotavirus disease activity in the United States, United Kingdom, and Mexico before and after introduction of rotavirus vaccine. We compared time series of internet searches for "rotavirus" from Google Trends with rotavirus laboratory reports from the United States and United Kingdom and with hospitalizations for acute gastroenteritis in the United States and Mexico. Using time and location parameters, Google quantifies an internet query share (IQS) to measure the relative search volume for specific terms. We analyzed the correlation between IQS and laboratory and hospitalization data before and after national vaccine introductions. There was a strong positive correlation between the rotavirus IQS and laboratory reports in the United States (R2 = 0.79) and United Kingdom (R2 = 0.60) and between the rotavirus IQS and acute gastroenteritis hospitalizations in the United States (R2 = 0.87) and Mexico (R2 = 0.69) (P United States and by 70% (95% CI, 55%-86%) in Mexico. In the United Kingdom, there was a loss of seasonal variation after vaccine introduction. Rotavirus internet search data trends mirrored national rotavirus laboratory trends in the United States and United Kingdom and gastroenteritis-hospitalization data in the United States and Mexico; lower correlations were found after rotavirus vaccine introduction. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  3. Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units.

    Science.gov (United States)

    Watanabe, Yuuki; Maeno, Seiya; Aoshima, Kenji; Hasegawa, Haruyuki; Koseki, Hitoshi

    2010-09-01

    The real-time display of full-range, 2048?axial pixelx1024?lateral pixel, Fourier-domain optical-coherence tomography (FD-OCT) images is demonstrated. The required speed was achieved by using dual graphic processing units (GPUs) with many stream processors to realize highly parallel processing. We used a zero-filling technique, including a forward Fourier transform, a zero padding to increase the axial data-array size to 8192, an inverse-Fourier transform back to the spectral domain, a linear interpolation from wavelength to wavenumber, a lateral Hilbert transform to obtain the complex spectrum, a Fourier transform to obtain the axial profiles, and a log scaling. The data-transfer time of the frame grabber was 15.73?ms, and the processing time, which includes the data transfer between the GPU memory and the host computer, was 14.75?ms, for a total time shorter than the 36.70?ms frame-interval time using a line-scan CCD camera operated at 27.9?kHz. That is, our OCT system achieved a processed-image display rate of 27.23 frames/s.

  4. Hierarchical control of motor units in voluntary contractions.

    Science.gov (United States)

    De Luca, Carlo J; Contessa, Paola

    2012-01-01

    For the past five decades there has been wide acceptance of a relationship between the firing rate of motor units and the afterhyperpolarization of motoneurons. It has been promulgated that the higher-threshold, larger-soma, motoneurons fire faster than the lower-threshold, smaller-soma, motor units. This relationship was based on studies on anesthetized cats with electrically stimulated motoneurons. We questioned its applicability to motor unit control during voluntary contractions in humans. We found that during linearly force-increasing contractions, firing rates increased as exponential functions. At any time and force level, including at recruitment, the firing rate values were inversely related to the recruitment threshold of the motor unit. The time constants of the exponential functions were directly related to the recruitment threshold. From the Henneman size principle it follows that the characteristics of the firing rates are also related to the size of the soma. The "firing rate spectrum" presents a beautifully simple control scheme in which, at any given time or force, the firing rate value of earlier-recruited motor units is greater than that of later-recruited motor units. This hierarchical control scheme describes a mechanism that provides an effective economy of force generation for the earlier-recruited lower force-twitch motor units, and reduces the fatigue of later-recruited higher force-twitch motor units-both characteristics being well suited for generating and sustaining force during the fight-or-flight response.

  5. Stroke treatment outcomes in hospitals with and without Stroke Units.

    Science.gov (United States)

    Masjuan, J; Gállego Culleré, J; Ignacio García, E; Mira Solves, J J; Ollero Ortiz, A; Vidal de Francisco, D; López-Mesonero, L; Bestué, M; Albertí, O; Acebrón, F; Navarro Soler, I M

    2017-10-23

    Organisational capacity in terms of resources and care circuits to shorten response times in new stroke cases is key to obtaining positive outcomes. This study compares therapeutic approaches and treatment outcomes between traditional care centres (with stroke teams and no stroke unit) and centres with stroke units. We conducted a prospective, quasi-experimental study (without randomisation of the units analysed) to draw comparisons between 2 centres with stroke units and 4 centres providing traditional care through the neurology department, analysing a selection of agreed indicators for monitoring quality of stroke care. A total of 225 patients participated in the study. In addition, self-administered questionnaires were used to collect patients' evaluations of the service and healthcare received. Centres with stroke units showed shorter response times after symptom onset, both in the time taken to arrive at the centre and in the time elapsed from patient's arrival at the hospital to diagnostic imaging. Hospitals with stroke units had greater capacity to respond through the application of intravenous thrombolysis than centres delivering traditional neurological care. Centres with stroke units showed a better fit to the reference standards for stroke response time, as calculated in the Quick study, than centres providing traditional care through the neurology department. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Intérvalo unitario de tiempo de medición para ruido ambiental Unit timing for environmental noise measurements

    Directory of Open Access Journals (Sweden)

    William A. Giraldo A.

    2011-01-01

    Full Text Available En las entidades ambientales, los encargados de las mediciones de ruido ambiental y en general todas las personas que de una u otra forma han trabajado en esta temática, en algún momento se han puesto a pensar sobre la representatividad del tiempo unitario de muestreo y la forma de realizar evaluaciones para dar cumplimiento con dicho tiempo, sin que se aumenten considerablemente los costos de medición. En este artículo se plantea una metodología para determinar cómo un intervalo de cierta duración -en este caso, quince (15 minutos- para el muestreo del nivel de presión sonora es representativo para el período de una (1 hora, logrando de esta manera optimizar el uso de los sonómetros "fijos" y proponiendo una estrategia para reducir los costos en las mediciones de ruido ambiental y en general la elaboración de mapas de ruido.The managers of environmental noise measurements in environmental control agencies, or in general every person that work in this subject, have to think on the representativity of the unit measurement time interval, and how to evaluate it in order to get good quality results regarding the unit measurement time without increasing the measurement costs. A methodology for deciding if a certain measuring time interval -in this case, fifteen (15 minutes- is representative of noise pressure levels occurring during one hour, is proposed in this paper. This methodology allows to optimize the use of stationary sound level meters and to propose a strategy for reducing the costs of environmental noise measurements and of the designing of noise maps in general.

  7. Unintentional falls mortality among elderly in the United States: time for action.

    Science.gov (United States)

    Alamgir, Hasanat; Muazzam, Sana; Nasrullah, Muazzam

    2012-12-01

    Fall injury is a leading cause of death and disability among older adults. The objective of this study is to identify the groups among the ≥ 65 population by age, gender, race, ethnicity and state of residence which are most vulnerable to unintentional fall mortality and report the trends in falls mortality in the United States. Using mortality data from the Centers for Disease Control and Prevention, the age specific and age-adjusted fall mortality rates were calculated by gender, age, race, ethnicity and state of residence for a five year period (2003-2007). Annual percentage changes in rates were calculated and linear regression using natural logged rates were used for time-trend analysis. There were 79,386 fall fatalities (rate: 40.77 per 100,000 population) reported. The annual mortality rate varied from a low of 36.76 in 2003 to a high of 44.89 in 2007 with a 22.14% increase (p=0.002 for time-related trend) during 2003-2007. The rates among whites were higher compared to blacks (43.04 vs. 18.83; p=0.01). While comparing falls mortality rate for race by gender, white males had the highest mortality rate followed by white females. The rate was as low as 20.19 for Alabama and as high as 97.63 for New Mexico. The relative attribution of falls mortality among all unintentional injury mortality increased with age (23.19% for 65-69 years and 53.53% for 85+ years), and the proportion of falls mortality was significantly higher among females than males (46.9% vs. 40.7%: p<0.001) and among whites than blacks (45.3% vs. 24.7%: p<0.001). The burden of fall related mortality is very high and the rate is on the rise; however, the burden and trend varied by gender, age, race and ethnicity and also by state of residence. Strategies will be more effective in reducing fall-related mortality when high risk population groups are targeted. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Time Investment and Time Management: An Analysis of Time Students Spend Working at Home for School

    Science.gov (United States)

    Wagner, Petra; Schober, Barbara; Spiel, Christiane

    2008-01-01

    This paper deals with the time students spend working at home for school. In Study 1, we investigated amount and regulation of time. Study 2 serves to validate the results of Study 1 and, in addition, investigates the duration of the time units students used and their relation to scholastic success. In Study 1, the participants were 332 students…

  9. Time-series Oxygen-18 Precipitation Isoscapes for Canada and the Northern United States

    Science.gov (United States)

    Delavau, Carly J.; Chun, Kwok P.; Stadnyk, Tricia A.; Birks, S. Jean; Welker, Jeffrey M.

    2014-05-01

    The present and past hydrological cycle from the watershed to regional scale can be greatly enhanced using water isotopes (δ18O and δ2H), displayed today as isoscapes. The development of water isoscapes has both hydrological and ecological applications, such as ground water recharge and food web ecology, and can provide critical information when observations are not available due to spatial and temporal gaps in sampling and data networks. This study focuses on the creation of δ18O precipitation (δ18Oppt) isoscapes at a monthly temporal frequency across Canada and the northern United States (US) utilizing CNIP (Canadian Network for Isotopes in Precipitation) and USNIP (United States Network for Isotopes in Precipitation) measurements. Multiple linear stepwise regressions of CNIP and USNIP observations alongside NARR (North American Regional Reanalysis) climatological variables, teleconnection indices, and geographic indicators are utilized to create empirical models that predict the δ18O of monthly precipitation across Canada and the northern US. Pooling information from nearby locations within a region can be useful due to the similarity of processes and mechanisms controlling the variability of δ18O. We expect similarity in the controls on isotopic composition to strengthen the correlation between δ18Oppt and predictor variables, resulting in model simulation improvements. For this reason, three different regionalization approaches are used to separate the study domain into 'isotope zones' to explore the effect of regionalization on model performance. This methodology results in 15 empirical models, five within each regionalization. A split sample calibration and validation approach is employed for model development, and parameter selection is based on demonstrated improvement of the Akaike Information Criteria (AIC). Simulation results indicate the empirical models are generally able to capture the overall monthly variability in δ18Oppt. For the three

  10. United States Policy and The Islamic Republic of Iran: A Time For Change

    National Research Council Canada - National Science Library

    Constantine, B

    2000-01-01

    .... This paper provides current information on Iran's government, economy, military, culture, religion, political process, and presents arguments for a change in current United States Policy concerning...

  11. 76 FR 61947 - Timely Mailing Treated as Timely Filing

    Science.gov (United States)

    2011-10-06

    ... regulations affect taxpayers who mail Federal tax documents to the Internal Revenue Service or the United... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 301 [TD 9543] RIN 1545-BA99 Timely Mailing Treated as Timely Filing AGENCY: Internal Revenue Service, Treasury. ACTION: Correcting amendment...

  12. Second Language Learners' Contiguous and Discontiguous Multi-Word Unit Use Over Time

    NARCIS (Netherlands)

    Yuldashev, Aziz; Fernandez, Julieta; Thorne, Steven L.

    Research has described the key role of formulaic language use in both written and spoken communication (Schmitt, 2004; Wray, 2002), as well as in relation to L2 learning (Ellis, Simpson-Vlach, & Maynard, 2008). Relatively few studies have examined related fixed and semifixed multi-word units (MWUs),

  13. Mathematical modelling and optimization of a large-scale combined cooling, heat, and power system that incorporates unit changeover and time-of-use electricity price

    International Nuclear Information System (INIS)

    Zhu, Qiannan; Luo, Xianglong; Zhang, Bingjian; Chen, Ying

    2017-01-01

    Highlights: • We propose a novel superstructure for the design and optimization of LSCCHP. • A multi-objective multi-period MINLP model is formulated. • The unit start-up cost and time-of-use electricity prices are involved. • Unit size discretization strategy is proposed to linearize the original MINLP model. • A case study is elaborated to demonstrate the effectiveness of the proposed method. - Abstract: Building energy systems, particularly large public ones, are major energy consumers and pollutant emission contributors. In this study, a superstructure of large-scale combined cooling, heat, and power system is constructed. The off-design unit, economic cost, and CO_2 emission models are also formulated. Moreover, a multi-objective mixed integer nonlinear programming model is formulated for the simultaneous system synthesis, technology selection, unit sizing, and operation optimization of large-scale combined cooling, heat, and power system. Time-of-use electricity price and unit changeover cost are incorporated into the problem model. The economic objective is to minimize the total annual cost, which comprises the operation and investment costs of large-scale combined cooling, heat, and power system. The environmental objective is to minimize the annual global CO_2 emission of large-scale combined cooling, heat, and power system. The augmented ε–constraint method is applied to achieve the Pareto frontier of the design configuration, thereby reflecting the set of solutions that represent optimal trade-offs between the economic and environmental objectives. Sensitivity analysis is conducted to reflect the impact of natural gas price on the combined cooling, heat, and power system. The synthesis and design of combined cooling, heat, and power system for an airport in China is studied to test the proposed synthesis and design methodology. The Pareto curve of multi-objective optimization shows that the total annual cost varies from 102.53 to 94.59 M

  14. Seasonal and annual precipitation time series trend analysis in North Carolina, United States

    Science.gov (United States)

    Sayemuzzaman, Mohammad; Jha, Manoj K.

    2014-02-01

    The present study performs the spatial and temporal trend analysis of the annual and seasonal time-series of a set of uniformly distributed 249 stations precipitation data across the state of North Carolina, United States over the period of 1950-2009. The Mann-Kendall (MK) test, the Theil-Sen approach (TSA) and the Sequential Mann-Kendall (SQMK) test were applied to quantify the significance of trend, magnitude of trend, and the trend shift, respectively. Regional (mountain, piedmont and coastal) precipitation trends were also analyzed using the above-mentioned tests. Prior to the application of statistical tests, the pre-whitening technique was used to eliminate the effect of autocorrelation of precipitation data series. The application of the above-mentioned procedures has shown very notable statewide increasing trend for winter and decreasing trend for fall precipitation. Statewide mixed (increasing/decreasing) trend has been detected in annual, spring, and summer precipitation time series. Significant trends (confidence level ≥ 95%) were detected only in 8, 7, 4 and 10 nos. of stations (out of 249 stations) in winter, spring, summer, and fall, respectively. Magnitude of the highest increasing (decreasing) precipitation trend was found about 4 mm/season (- 4.50 mm/season) in fall (summer) season. Annual precipitation trend magnitude varied between - 5.50 mm/year and 9 mm/year. Regional trend analysis found increasing precipitation in mountain and coastal regions in general except during the winter. Piedmont region was found to have increasing trends in summer and fall, but decreasing trend in winter, spring and on an annual basis. The SQMK test on "trend shift analysis" identified a significant shift during 1960 - 70 in most parts of the state. Finally, the comparison between winter (summer) precipitations with the North Atlantic Oscillation (Southern Oscillation) indices concluded that the variability and trend of precipitation can be explained by the

  15. Testing the Feasibility of Skype and FaceTime Updates With Parents in the Neonatal Intensive Care Unit.

    Science.gov (United States)

    Epstein, Elizabeth Gingell; Sherman, Jessica; Blackman, Amy; Sinkin, Robert A

    2015-07-01

    Effective provider-parent relationships are essential during critical illness when treatment decisions are complex, the environment is crowded and unfamiliar, and outcomes are uncertain. To evaluate the feasibility of daily Skype or FaceTime updates with parents of patients in the neonatal intensive care unit (NICU) and to assess the intervention's potential for improving parent-provider relationships. A pre/post mixed-methods approach was used. NICU parent participants received daily Skype or FaceTime updates for 5 days and completed demographic and feasibility surveys. Parents also completed Penticuff's Parents' Understanding survey before and after the intervention. Nurses and physicians completed feasibility surveys after each update. Twenty-six parents were enrolled and 15 completed the study. More than 90% of providers and parents perceived the intervention to be reliable and easy to use, and about 80% of parents and providers rated video and audio quality as either excellent or good. Frozen screens and missed updates due to scheduling problems were challenges. Two of the 4 subscores on the Parents' Understanding survey improved significantly. Qualitative data favor the intervention as meaningful for parents. Real-time videoconferencing via Skype or FaceTime is feasible for providing updates for parents when they cannot be present in the NICU and can be used to include parents in bedside rounds. Videoconferencing updates may improve relationships between parents and the health care team. ©2015 American Association of Critical-Care Nurses.

  16. Assessment of full-time faculty preceptors by colleges and schools of pharmacy in the United States and Puerto Rico.

    Science.gov (United States)

    Kirschenbaum, Harold L; Zerilli, Tina

    2012-10-12

    To identify the manner in which colleges and schools of pharmacy in the United States and Puerto Rico assess full-time faculty preceptors. Directors of pharmacy practice (or equivalent title) were invited to complete an online, self-administered questionnaire. Seventy of the 75 respondents (93.3%) confirmed that their college or school assessed full-time pharmacy faculty members based on activities related to precepting students at a practice site. The most commonly reported assessment components were summative student evaluations (98.5%), type of professional service provided (92.3%), scholarly accomplishments (86.2%), and community service (72.3%). Approximately 42% of respondents indicated that a letter of evaluation provided by a site-based supervisor was included in their assessment process. Some colleges and schools also conducted onsite assessment of faculty members. Most colleges and schools of pharmacy assess full-time faculty-member preceptors via summative student assessments, although other strategies are used. Given the important role of preceptors in ensuring students are prepared for pharmacy practice, colleges and schools of pharmacy should review their assessment strategies for full-time faculty preceptors, keeping in mind the methodologies used by other institutions.

  17. Real-time autocorrelator for fluorescence correlation spectroscopy based on graphical-processor-unit architecture: method, implementation, and comparative studies

    Science.gov (United States)

    Laracuente, Nicholas; Grossman, Carl

    2013-03-01

    We developed an algorithm and software to calculate autocorrelation functions from real-time photon-counting data using the fast, parallel capabilities of graphical processor units (GPUs). Recent developments in hardware and software have allowed for general purpose computing with inexpensive GPU hardware. These devices are more suited for emulating hardware autocorrelators than traditional CPU-based software applications by emphasizing parallel throughput over sequential speed. Incoming data are binned in a standard multi-tau scheme with configurable points-per-bin size and are mapped into a GPU memory pattern to reduce time-expensive memory access. Applications include dynamic light scattering (DLS) and fluorescence correlation spectroscopy (FCS) experiments. We ran the software on a 64-core graphics pci card in a 3.2 GHz Intel i5 CPU based computer running Linux. FCS measurements were made on Alexa-546 and Texas Red dyes in a standard buffer (PBS). Software correlations were compared to hardware correlator measurements on the same signals. Supported by HHMI and Swarthmore College

  18. Contamination analysis unit

    International Nuclear Information System (INIS)

    Gregg, H.R.; Meltzer, M.P.

    1996-01-01

    The portable Contamination Analysis Unit (CAU) measures trace quantities of surface contamination in real time. The detector head of the portable contamination analysis unit has an opening with an O-ring seal, one or more vacuum valves and a small mass spectrometer. With the valve closed, the mass spectrometer is evacuated with one or more pumps. The O-ring seal is placed against a surface to be tested and the vacuum valve is opened. Data is collected from the mass spectrometer and a portable computer provides contamination analysis. The CAU can be used to decontaminate and decommission hazardous and radioactive surfaces by measuring residual hazardous surface contamination, such as tritium and trace organics. It provides surface contamination data for research and development applications as well as real-time process control feedback for industrial cleaning operations and can be used to determine the readiness of a surface to accept bonding or coatings. 1 fig

  19. 76 FR 62607 - Timely Mailing Treated as Timely Filing

    Science.gov (United States)

    2011-10-11

    ... affect taxpayers who mail Federal tax documents to the Internal Revenue service or the United States Tax... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 301 [TD 9543] RIN 1545-BA99 Timely Mailing Treated as Timely Filing AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Correction to...

  20. Use of palivizumab and infection control measures to control an outbreak of respiratory syncytial virus in a neonatal intensive care unit confirmed by real-time polymerase chain reaction.

    LENUS (Irish Health Repository)

    O'Connell, K

    2011-04-01

    Respiratory syncytial virus (RSV) is a potentially life-threatening infection in premature infants. We report an outbreak involving four infants in the neonatal intensive care unit (NICU) of our hospital that occurred in February 2010. RSV A infection was confirmed by real-time polymerase chain reaction. Palivizumab was administered to all infants in the NICU. There were no additional symptomatic cases and repeat RSV surveillance confirmed that there was no further cross-transmission within the unit. The outbreak highlighted the infection control challenge of very high bed occupancy in the unit and the usefulness of molecular methods in facilitating detection and management.

  1. The United Nations, Peace, and Higher Education: Pedagogic Interventions in Neoliberal Times

    Science.gov (United States)

    Kester, Kevin

    2017-01-01

    Peace and conflict studies (PACS) education in recent decades has become a popular approach to social justice learning in higher education institutions (Harris, Fisk, and Rank 1998; Smith 2007; Carstarphen et al. 2010; Bajaj and Hantzopoulos 2016) and has been provided legitimacy through a number of different United Nations (UN) declarations…

  2. Training for the future NHS: training junior doctors in the United Kingdom within the 48-hour European working time directive.

    Science.gov (United States)

    Datta, Shreelatta T; Davies, Sally J

    2014-01-01

    Since August 2009, the National Health Service of the United Kingdom has faced the challenge of delivering training for junior doctors within a 48-hour working week, as stipulated by the European Working Time Directive and legislated in the UK by the Working Time Regulations 1998. Since that time, widespread concern has been expressed about the impact of restricted duty hours on the quality of postgraduate medical training in the UK, particularly in the "craft" specialties--that is, those disciplines in which trainees develop practical skills that are best learned through direct experience with patients. At the same time, specialist training in the UK has experienced considerable change since 2007 with the introduction of competency-based specialty curricula, workplace-based assessment, and the annual review of competency progression. The challenges presented by the reduction of duty hours include increased pressure on doctors-in-training to provide service during evening and overnight hours, reduced interaction with supervisors, and reduced opportunities for learning. This paper explores these challenges and proposes potential responses with respect to the reorganization of training and service provision.

  3. SI units in radiation protection

    International Nuclear Information System (INIS)

    Jain, V.K.; Soman, S.D.

    1978-01-01

    International System of Units abbreviated as SI units has been adopted by most of the countries of the world. Following this development, the implementation of SI units has become mandatory with a transition period of about ten years. Some of the journals have already adopted the SI units and any material sent for publication to them must use only these. International Commission on Radiation Units and Measurement (ICRU) published letters in several journals including Physics in Medicine and Biology, Health Physics, British Journal of Radiology, etc. outlining the latest recommendations on SI units to elicit the reactions of scientists in the general field of radiological sciences. Reactions to the letters were numerous as can be seen in the correspondence columns of these journals for the last few years and ranged from great misgivings and apprehension to support and appreciation. SI units have also been the subject of editorial comments in several journals. On the basis of a survey of this literature, it may be said that there was general agreement on the long term advantage of SI units inspite of some practical difficulties in their use particularly in the initial stages. This report presents a review of SI units in radiological sciences with a view to familiarize the users with the new units in terms of the old. A time table for the gradual changeover to the SI units is also outlined. (auth.)

  4. SI units in biomedical dosimetry

    International Nuclear Information System (INIS)

    Liden, K.

    1975-01-01

    The International commission on radiation units and measurements (ICRU), during the period from 1953 to 1962 presented its definitions of the quantities absorbed dose, exposure, activity, and dose equivalent and the corresponding special units the rad, the roentgen, the curie, and the rem. At the same time an international practical system of units was developed, Le Systeme International d'Unites (SI). It was adopted by the 11th Conference Generale des Poids et Mesures (CGPM) in 1960 and is now officially introduced in almost all countries. The general implementation of the SI means difficulties for the future use of the special radiation units, because the numerical factors involved prevent their adoption as SI units. In view of this, and after having sampled the opinion in the radiological field, the ICRU prepared a Statement on Units in July, 1974 which was forwarded to the Comite International des Poids et Mesures (CIPM) and its Comite Consultatif des Unites (CCU) for consideration. As a result of this statement the CIPM has now proposed, that the 15rh CGPM adopt special names for two SI units, namely the becquerel, symbol Bq, for the unit of activity of radionuclides equal to the reciprocal second, s 1- , and the gray, symbol Gy, for the unit of absorbed dose equal to the joule per kilogram, J/kg. The 15th CGPM will consider this matter in May, 1975. (author)

  5. An Efficient Explicit-time Description Method for Timed Model Checking

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2009-12-01

    Full Text Available Timed model checking, the method to formally verify real-time systems, is attracting increasing attention from both the model checking community and the real-time community. Explicit-time description methods verify real-time systems using general model constructs found in standard un-timed model checkers. Lamport proposed an explicit-time description method using a clock-ticking process (Tick to simulate the passage of time together with a group of global variables to model time requirements. Two methods, the Sync-based Explicit-time Description Method using rendezvous synchronization steps and the Semaphore-based Explicit-time Description Method using only one global variable were proposed; they both achieve better modularity than Lamport's method in modeling the real-time systems. In contrast to timed automata based model checkers like UPPAAL, explicit-time description methods can access and store the current time instant for future calculations necessary for many real-time systems, especially those with pre-emptive scheduling. However, the Tick process in the above three methods increments the time by one unit in each tick; the state spaces therefore grow relatively fast as the time parameters increase, a problem when the system's time period is relatively long. In this paper, we propose a more efficient method which enables the Tick process to leap multiple time units in one tick. Preliminary experimental results in a high performance computing environment show that this new method significantly reduces the state space and improves both the time and memory efficiency.

  6. Non-linear Loudspeaker Unit Modelling

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Agerkvist, Finn T.

    2008-01-01

    Simulations of a 6½-inch loudspeaker unit are performed and compared with a displacement measurement. The non-linear loudspeaker model is based on the major nonlinear functions and expanded with time-varying suspension behaviour and flux modulation. The results are presented with FFT plots of thr...... frequencies and different displacement levels. The model errors are discussed and analysed including a test with loudspeaker unit where the diaphragm is removed....

  7. Conceptual Model of Quantities, Units, Dimensions, and Values

    Science.gov (United States)

    Rouquette, Nicolas F.; DeKoenig, Hans-Peter; Burkhart, Roger; Espinoza, Huascar

    2011-01-01

    JPL collaborated with experts from industry and other organizations to develop a conceptual model of quantities, units, dimensions, and values based on the current work of the ISO 80000 committee revising the International System of Units & Quantities based on the International Vocabulary of Metrology (VIM). By providing support for ISO 80000 in SysML via the International Vocabulary of Metrology (VIM), this conceptual model provides, for the first time, a standard-based approach for addressing issues of unit coherence and dimensional analysis into the practice of systems engineering with SysML-based tools. This conceptual model provides support for two kinds of analyses specified in the International Vocabulary of Metrology (VIM): coherence of units as well as of systems of units, and dimension analysis of systems of quantities. To provide a solid and stable foundation, the model for defining quantities, units, dimensions, and values in SysML is explicitly based on the concepts defined in VIM. At the same time, the model library is designed in such a way that extensions to the ISQ (International System of Quantities) and SI Units (Systeme International d Unites) can be represented, as well as any alternative systems of quantities and units. The model library can be used to support SysML user models in various ways. A simple approach is to define and document libraries of reusable systems of units and quantities for reuse across multiple projects, and to link units and quantity kinds from these libraries to Unit and QuantityKind stereotypes defined in SysML user models.

  8. 75 FR 25925 - United States Mint

    Science.gov (United States)

    2010-05-10

    ... Committee May 25, 2010 Public Meeting. SUMMARY: Pursuant to United States Code, Title 31, section 5135(b)(8... scheduled for May 25, 2010. Date: May 25, 2010. Time: 9 a.m. to 12 p.m. Location: 8th Floor Board Room, United States Mint, 801 9th Street, NW., Washington, DC 20220. Subject: Review and discuss obverse and...

  9. Second Language Learners' Contiguous and Discontiguous Multi-Word Unit Use over Time

    Science.gov (United States)

    Yuldashev, Aziz; Fernandez, Julieta; Thorne, Steven L.

    2013-01-01

    Research has described the key role of formulaic language use in both written and spoken communication (Schmitt, 2004; Wray, 2002), as well as in relation to L2 learning (Ellis, Simpson--Vlach, & Maynard, 2008). Relatively few studies have examined related fixed and semi-fixed multi-word units (MWUs), which comprise fixed parts with the potential…

  10. Pickering Unit 1 chemical cleaning

    International Nuclear Information System (INIS)

    Smee, J.L.; Fiola, R.J.; Brennenstuhl, K.R.; Zerkee, D.D.; Daniel, C.M.

    1995-01-01

    The secondary sides of all 12 boilers at Pickering Unit 1 were chemically cleaned in 1994 by the team of Ontario Hydro, B and W International (Cambridge, Ontario) and B and W Nuclear Technologies (Lynchburg, Virginia). A multi-step EPRI/SGOG process was employed in a similar manner to previous clearings at Units 5 and 6 in 1992 and 1993, respectively. A major innovation with the Unit 1 cleaning was the incorporation of a crevice cleaning step, the first time this had been done on Ontario Hydro plants. In addition, six boilers were cleaned in parallel compared to three at a time in previous Pickering cleanings. This significantly reduced cleaning time. A total of 6,770 kg of sludge was removed through direct chemical dissolution. It consisted of 66% iron/nickel oxides and 28% copper metal. A total of 1,600,000 L (420,000 US gallons) of liquid waste was produced. It was processed through the spent solvent treatment facility located at the Bruce Nuclear Power Development site. Visual inspection performed after the cleaning indicated that the crevices between the boiler tubes and the tube support structure were completely clear of deposit and the general condition of the tubing and lattice bars appeared to be in 'as new' condition. (author)

  11. Effect of just-in-time simulation training on tracheal intubation procedure safety in the pediatric intensive care unit.

    Science.gov (United States)

    Nishisaki, Akira; Donoghue, Aaron J; Colborn, Shawn; Watson, Christine; Meyer, Andrew; Brown, Calvin A; Helfaer, Mark A; Walls, Ron M; Nadkarni, Vinay M

    2010-07-01

    Tracheal intubation-associated events (TIAEs) are common (20%) and life threatening (4%) in pediatric intensive care units. Physician trainees are required to learn tracheal intubation during intensive care unit rotations. The authors hypothesized that "just-in-time" simulation-based intubation refresher training would improve resident participation, success, and decrease TIAEs. For 14 months, one of two on-call residents, nurses, and respiratory therapists received 20-min multidisciplinary simulation-based tracheal intubation training and 10-min resident skill refresher training at the beginning of their on-call period in addition to routine residency education. The rate of first attempt and overall success between refresher-trained and concurrent non-refresher-trained residents (controls) during the intervention phase was compared. The incidence of TIAEs between preintervention and intervention phase was also compared. Four hundred one consecutive primary orotracheal intubations were evaluated: 220 preintervention and 181 intervention. During intervention phase, neither first-attempt success nor overall success rate differed between refresher-trained residents versus concurrent non-refresher-trained residents: 20 of 40 (50%) versus 15 of 24 (62.5%), P = 0.44 and 23 of 40 (57.5%) versus 18 of 24 (75.0%), P = 0.19, respectively. The resident's first attempt and overall success rate did not differ between preintervention and intervention phases. The incidence of TIAE during preintervention and intervention phases was similar: 22.0% preintervention versus 19.9% intervention, P = 0.62, whereas resident participation increased from 20.9% preintervention to 35.4% intervention, P = 0.002. Resident participation continued to be associated with TIAE even after adjusting for the phase and difficult airway condition: odds ratio 2.22 (95% CI 1.28-3.87, P = 0.005). Brief just-in-time multidisciplinary simulation-based intubation refresher training did not improve the resident

  12. Principles of applying Poisson units in radiology

    International Nuclear Information System (INIS)

    Benyumovich, M.S.

    2000-01-01

    The probability that radioactive particles hit particular space patterns (e.g. cells in the squares of a count chamber net) and time intervals (e.g. radioactive particles hit a given area per time unit) follows the Poisson distribution. The mean is the only parameter from which all this distribution depends. A metrological base of counting the cells and radioactive particles is a property of the Poisson distribution assuming equality of a standard deviation to a root square of mean (property 1). The application of Poisson units in counting of blood formed elements and cultured cells was proposed by us (Russian Federation Patent No. 2126230). Poisson units relate to the means which make the property 1 valid. In a case of cells counting, the square of these units is equal to 1/10 of one of count chamber net where they count the cells. Thus one finds the means from the single cell count rate divided by 10. Finding the Poisson units when counting the radioactive particles should assume determination of a number of these particles sufficient to make equality 1 valid. To this end one should subdivide a time interval used in counting a single particle count rate into different number of equal portions (count numbers). Next one should pick out the count number ensuring the satisfaction of equality 1. Such a portion is taken as a Poisson unit in the radioactive particles count. If the flux of particles is controllable one should set up a count rate sufficient to make equality 1 valid. Operations with means obtained by with the use of Poisson units are performed on the base of approximation of the Poisson distribution by a normal one. (author)

  13. Graphics processing unit accelerated intensity-based optical coherence tomography angiography using differential frames with real-time motion correction.

    Science.gov (United States)

    Watanabe, Yuuki; Takahashi, Yuhei; Numazawa, Hiroshi

    2014-02-01

    We demonstrate intensity-based optical coherence tomography (OCT) angiography using the squared difference of two sequential frames with bulk-tissue-motion (BTM) correction. This motion correction was performed by minimization of the sum of the pixel values using axial- and lateral-pixel-shifted structural OCT images. We extract the BTM-corrected image from a total of 25 calculated OCT angiographic images. Image processing was accelerated by a graphics processing unit (GPU) with many stream processors to optimize the parallel processing procedure. The GPU processing rate was faster than that of a line scan camera (46.9 kHz). Our OCT system provides the means of displaying structural OCT images and BTM-corrected OCT angiographic images in real time.

  14. A graphics processing unit accelerated motion correction algorithm and modular system for real-time fMRI.

    Science.gov (United States)

    Scheinost, Dustin; Hampson, Michelle; Qiu, Maolin; Bhawnani, Jitendra; Constable, R Todd; Papademetris, Xenophon

    2013-07-01

    Real-time functional magnetic resonance imaging (rt-fMRI) has recently gained interest as a possible means to facilitate the learning of certain behaviors. However, rt-fMRI is limited by processing speed and available software, and continued development is needed for rt-fMRI to progress further and become feasible for clinical use. In this work, we present an open-source rt-fMRI system for biofeedback powered by a novel Graphics Processing Unit (GPU) accelerated motion correction strategy as part of the BioImage Suite project ( www.bioimagesuite.org ). Our system contributes to the development of rt-fMRI by presenting a motion correction algorithm that provides an estimate of motion with essentially no processing delay as well as a modular rt-fMRI system design. Using empirical data from rt-fMRI scans, we assessed the quality of motion correction in this new system. The present algorithm performed comparably to standard (non real-time) offline methods and outperformed other real-time methods based on zero order interpolation of motion parameters. The modular approach to the rt-fMRI system allows the system to be flexible to the experiment and feedback design, a valuable feature for many applications. We illustrate the flexibility of the system by describing several of our ongoing studies. Our hope is that continuing development of open-source rt-fMRI algorithms and software will make this new technology more accessible and adaptable, and will thereby accelerate its application in the clinical and cognitive neurosciences.

  15. Real-time acquisition and display of flow contrast using speckle variance optical coherence tomography in a graphics processing unit.

    Science.gov (United States)

    Xu, Jing; Wong, Kevin; Jian, Yifan; Sarunic, Marinko V

    2014-02-01

    In this report, we describe a graphics processing unit (GPU)-accelerated processing platform for real-time acquisition and display of flow contrast images with Fourier domain optical coherence tomography (FDOCT) in mouse and human eyes in vivo. Motion contrast from blood flow is processed using the speckle variance OCT (svOCT) technique, which relies on the acquisition of multiple B-scan frames at the same location and tracking the change of the speckle pattern. Real-time mouse and human retinal imaging using two different custom-built OCT systems with processing and display performed on GPU are presented with an in-depth analysis of performance metrics. The display output included structural OCT data, en face projections of the intensity data, and the svOCT en face projections of retinal microvasculature; these results compare projections with and without speckle variance in the different retinal layers to reveal significant contrast improvements. As a demonstration, videos of real-time svOCT for in vivo human and mouse retinal imaging are included in our results. The capability of performing real-time svOCT imaging of the retinal vasculature may be a useful tool in a clinical environment for monitoring disease-related pathological changes in the microcirculation such as diabetic retinopathy.

  16. Unit root vector autoregression with volatility induced stationarity

    DEFF Research Database (Denmark)

    Rahbek, Anders; Nielsen, Heino Bohn

    We propose a discrete-time multivariate model where lagged levels of the process enter both the conditional mean and the conditional variance. This way we allow for the empirically observed persistence in time series such as interest rates, often implying unit-roots, while at the same time maintain...... and geometrically ergodic. Interestingly, these conditions include the case of unit roots and a reduced rank structure in the conditional mean, known from linear co-integration to imply non-stationarity. Asymptotic theory of the maximum likelihood estimators for a particular structured case (so-called self...

  17. Unit Root Vector Autoregression with volatility Induced Stationarity

    DEFF Research Database (Denmark)

    Rahbek, Anders; Nielsen, Heino Bohn

    We propose a discrete-time multivariate model where lagged levels of the process enter both the conditional mean and the conditional variance. This way we allow for the empirically observed persistence in time series such as interest rates, often implying unit-roots, while at the same time maintain...... and geometrically ergodic. Interestingly, these conditions include the case of unit roots and a reduced rank structure in the conditional mean, known from linear co-integration to imply non-stationarity. Asymptotic theory of the maximum likelihood estimators for a particular structured case (so-called self...

  18. Comparative study of radiation dose between digital panoramic X-ray unit and general panoramic X-ray unit

    International Nuclear Information System (INIS)

    Li Qingshan; Duan Tao; Wang Xiaoyun; Zhao Li; Dong Jian; Wei Lei

    2010-01-01

    Objective: To compare the actual dose of patients who receive the same medical practice by either digital panoramic X-ray unit and general panoramic X-ray unit and give evidence for better selection of oral X-ray examination method. Methods: Round sheet lithium fluoride (LiF) thermoluminescent dosimeters (TLD) were used. The experiment was divided into natural background contrast group, general panoramic X-ray children group, general panoramic X-ray adults group, digital panoramic X-ray children group and digital panoramic X-ray adults group. The dosimeter of natural background radiation was placed at the office of the doctor, the dosimeters of general panoramic X-ray children group and general panoramic X-ray adults group were irradiated by different conditions according to the clinical application of panoramic X-ray to children and adults, the dosimeters of digital panoramic X-ray children group and digital panoramic X-ray adults group were irradiated by different conditions according to the clinical application of digital panoramic X-ray to children and adults. The thermoluminescent dosimeter was used to count and calculate the exposure doses in various groups. Results: The dose of children exposed in general panoramic X-ray unit was 1.28 times of that in digital panoramic X-ray unit, there was significant difference (t=6.904, P<0.01). The dose of adults exposed in general panoramic X-ray unit was 1.55 times of that in the digital panoramic X-ray unit, there also was significant difference (t=-11.514. P< 0.01). Conclusion: The digital panoramic X-ray unit can reduce the dose of patients, so the digital panoramic X-ray unit should be used as far as possible. (authors)

  19. Unit root behavior in energy futures prices

    OpenAIRE

    Serletis, Apostolos

    1992-01-01

    This paper re-examines the empirical evidence for random walk type behavior in energy futures prices. In doing so, tests for unit roots in the univariate time-series representation of the daily crude oil, heating oil, and unleaded gasoline series are performed using recent state-of-the-art methodology. The results show that the unit root hypothesis can be rejected if allowance is made for the possibility of a one-time break in the intercept and the slope of the trend function at an unknown po...

  20. A real-time GNSS-R system based on software-defined radio and graphics processing units

    Science.gov (United States)

    Hobiger, Thomas; Amagai, Jun; Aida, Masanori; Narita, Hideki

    2012-04-01

    Reflected signals of the Global Navigation Satellite System (GNSS) from the sea or land surface can be utilized to deduce and monitor physical and geophysical parameters of the reflecting area. Unlike most other remote sensing techniques, GNSS-Reflectometry (GNSS-R) operates as a passive radar that takes advantage from the increasing number of navigation satellites that broadcast their L-band signals. Thereby, most of the GNSS-R receiver architectures are based on dedicated hardware solutions. Software-defined radio (SDR) technology has advanced in the recent years and enabled signal processing in real-time, which makes it an ideal candidate for the realization of a flexible GNSS-R system. Additionally, modern commodity graphic cards, which offer massive parallel computing performances, allow to handle the whole signal processing chain without interfering with the PC's CPU. Thus, this paper describes a GNSS-R system which has been developed on the principles of software-defined radio supported by General Purpose Graphics Processing Units (GPGPUs), and presents results from initial field tests which confirm the anticipated capability of the system.

  1. Energy-efficient optical network units for OFDM PON based on time-domain interleaved OFDM technique.

    Science.gov (United States)

    Hu, Xiaofeng; Cao, Pan; Zhang, Liang; Jiang, Lipeng; Su, Yikai

    2014-06-02

    We propose and experimentally demonstrate a new scheme to reduce the energy consumption of optical network units (ONUs) in orthogonal frequency division multiplexing passive optical networks (OFDM PONs) by using time-domain interleaved OFDM (TI-OFDM) technique. In a conventional OFDM PON, each ONU has to process the complete downstream broadcast OFDM signal with a high sampling rate and a large FFT size to retrieve its required data, even if it employs a portion of OFDM subcarriers. However, in our scheme, the ONU only needs to sample and process one data group from the downlink TI-OFDM signal, effectively reducing the sampling rate and the FFT size of the ONU. Thus, the energy efficiency of ONUs in OFDM PONs can be greatly improved. A proof-of-concept experiment is conducted to verify the feasibility of the proposed scheme. Compared to the conventional OFDM PON, our proposal can save 17.1% and 26.7% energy consumption of ONUs by halving and quartering the sampling rate and the FFT size of ONUs with the use of the TI-OFDM technology.

  2. NZG 201 portable spectrometric unit

    International Nuclear Information System (INIS)

    Jursa, P.; Novakova, O.; Slezak, V.

    The NZG 201 spectrometric unit is a portable single-channel processing unit supplied from the mains or a battery which allows the qualitative and quantitative measurement of different types of ionizing radiation when connected to a suitable detection unit. The circuit layout and the choice of control elements makes the spectrometric unit suitable for use with scintillation detector units. The spectrometric unit consists of a pulse amplifier, an amplitude pulse analyzer, a pulse counter, a pulse rate counter with an output for a recorder, a high voltage source and a low voltage source. The block diagram is given. All circuits are modular and are mounted on PCB's. The apparatus is built in a steel cabinet with a raised edge which protects the control elements. The linear pulse amplifier has a maximum gain of 1024, the pulse counter has a maximum capacity of 10 6 -1 imp and time resolution better than 0.5 μs. The temperature interval at which the apparatus is operational is 0 to 45 degC, its weight is 12.5 kg and dimensions 36x280x310 mm, energy range O.025 to 2.5 MeV, for 137 Cs the energy resolution is 8 to 10%. The spectrometric unit NZG 2O1 may, with regard to its parameters, number and range of control elements, be used as a universal measuring unit. (J.P.)

  3. 40 CFR 60.2992 - What is an existing incineration unit?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What is an existing incineration unit... Times for Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Applicability of State Plans § 60.2992 What is an existing incineration unit? An existing incineration unit is...

  4. An intersection test for panel unit roots

    NARCIS (Netherlands)

    Hanck, C.

    2013-01-01

    This article proposes a new panel unit root test based on Simes' ( 1986) classical intersection test. The test is robust to general patterns of cross-sectional dependence and yet is straightforward to implement, only requiring p-values of time series unit root tests of the series in the panel, and

  5. Survey of diagnostic X-Ray units at Recife- Brazil

    International Nuclear Information System (INIS)

    Hazing, C.A.; Khoury, H.J.; Santos, R.S.; Antonino, P.D.

    1998-01-01

    This paper reports reports the result of a survey aiming to determine the working conditions of x-ray units operating in hospital and clinics in the city of Recife, Pernamburgo, Brazil. The study comprised 27 x-ray units from both public and private diagnostic services operating. The following parameters were evaluated: a) coincidence between the luminous and radiation fields; b) alignment of the radiation beam; c) agreement between the real and preset values of the kVp and exposure time. The result showed that the discrepancy between the luminous and radiation fields stayed in the recommended 1 to 2% interval in 78.2% of the equipment surveyed, all units passing the alignment test (deviation of less than 3%). The results also showed that there is only a fair accuracy regarding both preset kilovoltage and exposure time, with discrepancies of more than 10% between ''true'' irradiation times(in85% of the case), and between the present and applied kilovoltage (in 46% of the inspected units)

  6. Hanford Site Waste Managements Units reports

    International Nuclear Information System (INIS)

    1992-01-01

    The Hanford Site Waste Management Units Report (HSWMUR) was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments (HSWA) of the 1984 United States Code (USC 1984). This report provides a comprehensive inventory of all types of waste management units at the Hanford Site, including a description of the units and the waste they contain. Waste management units in this report include: (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment, storage, and disposal (TSD) units, and (6) other storage areas. Because of the comprehensive nature of this report, the listing of sites is more extensive than required by Section 3004(u) of HSWA. The information in this report is extracted from the Waste Information Data System (WIDS). The WIDS provides additional information concerning the waste management units contained in this report and is maintained current with changes to these units. This report is updated annually if determined necessary per the Hanford Federal Facility Agreement and Consent Order Order (commonly referred to as the Tri-Party Agreement, Ecology et al. 1990). This report identifies 1,414 waste management units. Of these, 1,015 units are identified as solid waste management units (SWMU), and 342 are RCRA treatment, storage, and disposal units. The remaining 399 are comprised mainly of one-time spills to the environment, sanitary waste disposal facilities (i.e., septic tanks), and surplus facilities awaiting decontamination and decommissioning

  7. A 'Universal Time' system for ASDEX upgrade

    International Nuclear Information System (INIS)

    Raupp, Gerhard; Cole, R.; Behler, K.; Fitzek, M.; Heimann, P.; Lohs, A.; Lueddecke, K.; Neu, G.; Schacht, J.; Treutterer, W.; Zasche, D.; Zehetbauer, Th.; Zilker, M.

    2003-01-01

    For the new generation of intelligent controllers for plasma diagnostics, discharge control and long-pulse experiment control a new time system supporting steady state real-time operation has been devised. A central unit counts time at nanosecond resolution, covering more than the experiment lifetime. The broadcast time information serves local units to perform application functions such as current time readout, trigger generation and sample time measurement. Time is treated as a precisely measured quantity like other physical quantities. Tagging all detected events and sampled values with measured times as [value; time]-entities facilitates real-time data analysis, steady state protocolling and time-sorted archiving

  8. Automatic control unit for A neutron diffraction crystal spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abbas, Y.; Mostafa, M.; Hamouda, I.

    1982-01-01

    An automatic transistorized unit has been designed and constructed to control the operation of the double axis crystal spectrometer installed in front of one of the horizontal channels of the ET-RR-1 reactor. The function of the automatic unit is to store the diffracted neutrons at a certain angle with respect to the direction of the incident neutron beam in a selected channel of a 1024-multichannel analyzer for a certain preadjusted time period. AT the end of this time period the unit rotates the spectrometer's arm to another angle, selects the next channel of the MCA and provides the measurement of the diffracted neutron for the same time period. Such a sequence is repeated automatically over all angles required for the neutron diffraction pattern of the sample under investigation. As a result, the stored information at the MCA provides the neutron diffraction pattern as a function of channel number, where each channel corresponds to a certain scattering angle. The stored distribution at MCA can be obtained through the analyzer read out unit. The designed automatic unit has the possibility of providing the neutron diffraction pattern using a 6-digit scaler and a printer.

  9. The impact of a noise reduction quality improvement project upon sound levels in the open-unit-design neonatal intensive care unit.

    Science.gov (United States)

    Liu, W F

    2010-07-01

    To decrease measured sound levels in the neonatal intensive care unit through implementation of human factor and minor design modification strategies. Prospective time series. Two open-unit-design neonatal centers. Implementation of a coordinated program of noise reduction strategies did not result in any measurable improvement in levels of loudness or quiet. Two centers, using primarily human behavior noise reduction strategies, were unable to demonstrate measurable improvements in sound levels within the occupied open-unit-design neonatal intensive care unit.

  10. Buying time promotes happiness

    NARCIS (Netherlands)

    Whillans, Ashley; Dunn, Elizabeth; Smeets, Paul M.; Bekkers, R.H.F.P.; Norton, M.I.

    2017-01-01

    Around the world, increases in wealth have produced an unintended consequence: a rising sense of time scarcity. We provide evidence that using money to buy time can provide a buffer against this time famine, thereby promoting happiness. Using large, diverse samples from the United States, Canada,

  11. Dependence of the paired motor unit analysis on motor unit discharge characteristics in the human tibialis anterior muscle

    Science.gov (United States)

    Stephenson, Jennifer L.; Maluf, Katrina S.

    2011-01-01

    The paired motor unit analysis provides in vivo estimates of the magnitude of persistent inward currents (PIC) in human motoneurons by quantifying changes in the firing rate (ΔF) of an earlier recruited (reference) motor unit at the time of recruitment and derecruitment of a later recruited (test) motor unit. This study assessed the variability of ΔF estimates, and quantified the dependence of ΔF on the discharge characteristics of the motor units selected for analysis. ΔF was calculated for 158 pairs of motor units recorded from nine healthy individuals during repeated submaximal contractions of the tibialis anterior muscle. The mean (SD) ΔF was 3.7 (2.5) pps (range −4.2 to 8.9 pps). The median absolute difference in ΔF for the same motor unit pair across trials was 1.8 pps, and the minimal detectable change in ΔF required to exceed measurement error was 4.8 pps. ΔF was positively related to the amount of discharge rate modulation in the reference motor unit (r2=0.335; Precruitment of the reference and test motor units (r2=0.229, Pmotor unit activity (r2=0.110, Precruitment threshold of the test motor unit (r2=0.237, Pmotor unit analysis. PMID:21459110

  12. Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States

    CERN Document Server

    Acciarri, R; Artrip, D; Baller, B; Bromberg, C; Cavanna, F; Carls, B; Chen, H; Deptuch, G; Epprecht, L; Dharmapalan, R; Foreman, W; Hahn, A; Johnson, M; Jones, B J P; Junk, T; Lang, K; Lockwitz, S; Marchionni, A; Mauger, C; Montanari, C; Mufson, S; Nessi, M; Back, H Olling; Petrillo, G; Pordes, S; Raaf, J; Rebel, B; Sinins, G; Soderberg, M; Spooner, N J C; Stancari, M; Strauss, T; Terao, K; Thorn, C; Tope, T; Toups, M; Urheim, J; Van de Water, R; Wang, H; Wasserman, R; Weber, M; Whittington, D; Yang, T

    2015-01-01

    The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six topical plenary sessions: $i)$ Argon Purity and Cryogenics, $ii)$ TPC and High Voltage, $iii)$ Electronics, Data Acquisition and Triggering, $iv)$ Scintillation Light Detection, $v)$ Calibration and Test Beams, and $vi)$ Software. This document summarizes the current efforts in each of these areas. It primarily focuses on the work in the US, but also highlights work done elsewhere in the world.

  13. Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Acciarri, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); et al.

    2015-04-21

    The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six topical plenary sessions: i) Argon Purity and Cryogenics, ii) TPC and High Voltage, iii) Electronics, Data Acquisition and Triggering, iv) Scintillation Light Detection, v) Calibration and Test Beams, and vi) Software. This document summarizes the current efforts in each of these areas. It primarily focuses on the work in the US, but also highlights work done elsewhere in the world.

  14. 2000, the centenary of the birth of Frederic Joliot

    International Nuclear Information System (INIS)

    Radvanyi, P.

    2000-01-01

    This article is a short biography of Frederic Joliot. In 1935 F. Joliot and his wife Irene Curie received the Nobel prize of chemistry for their discovery of artificial radioactivity. In january 1939 F.Joliot acknowledged the results of O. Hahn and F. Strassmann about a new nuclear process called fission and he performed a very simple experiment in order to prove fission experimentally by observing fission fragments. Later F.Joliot imagined the possibility of a chain reaction made up of successive fissions self-sustained by the neutrons emitted and able to produce energy. In the same time, similar ideas were developed by E.Fermi's team at Columbia University in New-York. The saga of the quest for heavy water during world war two is recalled. In 1946 F.Joliot was appointed as the first director of the recently created French ''Commissariat a l'energie atomique'' (CEA), in march 1950 he wrote and signed the first ''appel de Stockholm'' where he called for an absolute forbidding of non-peaceful use of nuclear energy, in april he was removed from office. (A.C.)

  15. Economical analysis and study on a solar desalination unit

    DEFF Research Database (Denmark)

    of desalination unit and electrical power, the life time of solar desalination unit and the yearly yield of fresh water, on the cost of the fresh water production of the solar desalination unit are studied. It is helpful for the further investigation of solar desalination and for reducing the cost of fresh water...

  16. Department of Defense Precise Time and Time Interval program improvement plan

    Science.gov (United States)

    Bowser, J. R.

    1981-01-01

    The United States Naval Observatory is responsible for ensuring uniformity in precise time and time interval operations including measurements, the establishment of overall DOD requirements for time and time interval, and the accomplishment of objectives requiring precise time and time interval with minimum cost. An overview of the objectives, the approach to the problem, the schedule, and a status report, including significant findings relative to organizational relationships, current directives, principal PTTI users, and future requirements as currently identified by the users are presented.

  17. Interfacing Agents to Real-Time Strategy Games

    DEFF Research Database (Denmark)

    Jensen, Andreas Schmidt; Kaysø-Rørdam, Christian; Villadsen, Jørgen

    2015-01-01

    In real-time strategy games players make decisions and control their units simultaneously. Players are required to make decisions under time pressure and should be able to control multiple units at once in order to be successful. We present the design and implementation of a multi-agent interface...

  18. On Point: The United States Army in Operation Iraqi Freedom

    Science.gov (United States)

    2004-01-01

    to retain operational context. Moreover, times noted in the text have been adjusted from Greenwich Mean Time (“ Zulu ”) to local Kuwait time (+ 3...TF 1-64 AR unit history is composed of short narratives for each subordinate unit. Most cite times in zulu . 34. Ibid. 35. Ibid. Numbers of enemy...places in the world. Inside the city cemetery is the Tomb of Ali, son-in-law and cousin to Mohammed and founder of the Shiite sect. Coalition leaders

  19. Optical Time Reversal from Time-Dependent Epsilon-Near-Zero Media

    Science.gov (United States)

    Vezzoli, Stefano; Bruno, Vincenzo; DeVault, Clayton; Roger, Thomas; Shalaev, Vladimir M.; Boltasseva, Alexandra; Ferrera, Marcello; Clerici, Matteo; Dubietis, Audrius; Faccio, Daniele

    2018-01-01

    Materials with a spatially uniform but temporally varying optical response have applications ranging from magnetic field-free optical isolators to fundamental studies of quantum field theories. However, these effects typically become relevant only for time variations oscillating at optical frequencies, thus presenting a significant hurdle that severely limits the realization of such conditions. Here we present a thin-film material with a permittivity that pulsates (uniformly in space) at optical frequencies and realizes a time-reversing medium of the form originally proposed by Pendry [Science 322, 71 (2008), 10.1126/science.1162087]. We use an optically pumped, 500 nm thick film of epsilon-near-zero (ENZ) material based on Al-doped zinc oxide. An incident probe beam is both negatively refracted and time reversed through a reflected phase-conjugated beam. As a result of the high nonlinearity and the refractive index that is close to zero, the ENZ film leads to time reversed beams (simultaneous negative refraction and phase conjugation) with near-unit efficiency and greater-than-unit internal conversion efficiency. The ENZ platform therefore presents the time-reversal features required, e.g., for efficient subwavelength imaging, all-optical isolators and fundamental quantum field theory studies.

  20. SUR. Breve informe de la Expedición Yelcho al Polo Sur (1909-1910

    Directory of Open Access Journals (Sweden)

    Ursula K. Le Guin

    2013-12-01

    Full Text Available Ursula K. Le Guin Escritora norteamericana, famosa por sus obras de ciencia fi cción y fantasía, en las cuales el tema de género ocupa una posición central. Ganadora de los premios Hugo y Nébula que la catapultaron a la fama. “SUR. A summary report of the Yelcho expedition to the Antarctic, 1909-1910”. Apáreció publicado por primera vez en la revista New Yorker, el 1° de febrero de 1982. La palabra SUR aparece en español en el original. (http://www.newyorker.com/ar Traducción de Susana E. Matallana Peláez

  1. SI units for radiation measurements : for or against

    International Nuclear Information System (INIS)

    Nagaratnam, A.; Reddy, A.R.

    1975-01-01

    The historical evolution of the International System of Units (SI) is traced and concepts regarding radiation quantities and units as given by the ICRU are presented. Implications of the changeover to SI units for radiation measurement from the conventional system of familiar units like curie, roentgen, rad and rem are discussed. The familiar units will be kept for the time being along with SI units. In order to avoid confusion in the changeover period, new names, namely, becquerel and gray have been suggested by the authors for the SI units for activity and absorbed dose respectively. One becquerel will be 1 nuclear transformation per second and is approximately equal to 2.703 x 10 -11 Ci. One gray will be 1 joule per kilogram and is exactly equal to 100 rad. (M.G.B.)

  2. The n-by-T Target Discharge Strategy for Inpatient Units.

    Science.gov (United States)

    Parikh, Pratik J; Ballester, Nicholas; Ramsey, Kylie; Kong, Nan; Pook, Nancy

    2017-07-01

    Ineffective inpatient discharge planning often causes discharge delays and upstream boarding. While an optimal discharge strategy that works across all units at a hospital is likely difficult to identify and implement, a strategy that provides a reasonable target to the discharge team appears feasible. We used observational and retrospective data from an inpatient trauma unit at a Level 2 trauma center in the Midwest US. Our proposed novel n-by-T strategy-discharge n patients by the Tth hour-was evaluated using a validated simulation model. Outcome measures included 2 measures: time-based (mean discharge completion and upstream boarding times) and capacity-based (increase in annual inpatient and upstream bed hours). Data from the pilot implementation of a 2-by-12 strategy at the unit was obtained and analyzed. The model suggested that the 1-by-T and 2-by-T strategies could advance the mean completion times by over 1.38 and 2.72 h, respectively (for 10 AM ≤ T ≤ noon, occupancy rate = 85%); the corresponding mean boarding time reductions were nearly 11% and 15%. These strategies could increase the availability of annual inpatient and upstream bed hours by at least 2,469 and 500, respectively. At 100% occupancy rate, the hospital-favored 2-by-12 strategy reduced the mean boarding time by 26.1%. A pilot implementation of the 2-by-12 strategy at the unit corroborated with the model findings: a 1.98-h advancement in completion times (Pstrategies, such as the n-by-T, can help substantially reduce discharge lateness and upstream boarding, especially during high unit occupancy. To sustain implementation, necessary commitment from the unit staff and physicians is vital, and may require some training.

  3. A Nonparametric Test for Seasonal Unit Roots

    OpenAIRE

    Kunst, Robert M.

    2009-01-01

    Abstract: We consider a nonparametric test for the null of seasonal unit roots in quarterly time series that builds on the RUR (records unit root) test by Aparicio, Escribano, and Sipols. We find that the test concept is more promising than a formalization of visual aids such as plots by quarter. In order to cope with the sensitivity of the original RUR test to autocorrelation under its null of a unit root, we suggest an augmentation step by autoregression. We present some evidence on the siz...

  4. Optimisasi Unit Commitment Mempertimbangkan Fungsi Biaya Tidak Mulus Dengan Firefly Algorithm

    Directory of Open Access Journals (Sweden)

    Benny Prastikha Hadhi

    2014-03-01

    Full Text Available Setiap unit pembangkit yang beroperasi untuk memenuhi permintaan beban mempunyai jadwal operasi yang berbeda-beda. Hal ini disebabkan oleh perbedaan karakteristik input-output yang khas dari setiap unit. Untuk memperoleh biaya total pembangkitan yang ekonomis dibutuhkan penjadwalan nyala-padam unit pembangkit yang terhubung pada sistem tenaga listrik, yang dikenal sebagai unit commitment (UC. Penjadwalan unit pembangkit pada suatu sistem tenaga listrik memiliki banyak pertimbangan, seperti cadangan berputar (spinning reserve, waktu menyala minimal (minimum up time, waktu padam minimal (minimum down time, rentang daya output unit pembangkit dan lain-lain. Selain itu, fungsi biaya pembangkitan unit yang mengoperasikan katup uap untuk mengimbangi perubahan beban menyebabkan persamaan fungsi biaya menjadi tidak mulus. Fungsi biaya tidak mulus mempersulit penjadwalan ekonomis unit pembangkit. Tugas akhir ini mengajukan Firefly Algorithm (FA untuk menyelesaikan penjadwalan UC. FA merupakan algoritma yang sederhana, tetapi handal dalam menyelesaikan permasalahan optimisasi. UC yang diajukan menggunakan fungsi biaya tidak mulus. Dengan metode tersebut, diharapkan permasalahan penjadwalan unit pembangkit dapat terselesaikan dengan baik dan optimal sehingga memperoleh biaya total pembangkitan yang ekonomis.

  5. Time-delay analyzer with continuous discretization

    International Nuclear Information System (INIS)

    Bayatyan, G.L.; Darbinyan, K.T.; Mkrtchyan, K.K.; Stepanyan, S.S.

    1988-01-01

    A time-delay analyzer is described which when triggered by a start pulse of adjustable duration performs continuous discretization of the analyzed signal within nearly 22 ns time intervals, the recording in a memory unit with following slow read-out of the information to the computer and its processing. The time-delay analyzer consists of four CAMAC-VECTOR systems of unit width. With its help one can separate comparatively short, small-amplitude rare signals against the background of quasistationary noise processes. 4 refs.; 3 figs

  6. Dynamic optimization of a FCC converter unit: numerical analysis

    Directory of Open Access Journals (Sweden)

    E. Almeida Nt

    2011-03-01

    Full Text Available Fluidized-bed Catalytic Cracking (FCC is a process subject to frequent variations in the operating conditions (including feed quality and feed rate. The production objectives usually are the maximization of LPG and gasoline production. This fact makes the FCC converter unit an excellent opportunity for real-time optimization. The present work aims to apply a dynamic optimization in an industrial FCC converter unit, using a mechanistic dynamic model, and to carry out a numerical analysis of the solution procedure. A simultaneous approach was used to discretize the system of differential-algebraic equations and the resulting large-scale NLP problem was solved using the IPOPT solver. This study also does a short comparison between the results obtained by a potential dynamic real-time optimization (DRTO against a possible steady-state real-time optimization (RTO application. The results demonstrate that the application of dynamic real-time optimization of a FCC converter unit can bring significant benefits in production.

  7. Real-time Measurements of an Optical Reconfigurable Radio Access Unit for 5G Wireless Access Networks

    DEFF Research Database (Denmark)

    Rodríguez, Sebastián; Morales Vicente, Alvaro; Rommel, Simon

    2017-01-01

    A reconfigurable radio access unit able to switch wavelength, RF carrier frequency and optical path is experimentally demonstrated. The system is able to do the switching processes correctly, while achieving BER values below FEC limit.......A reconfigurable radio access unit able to switch wavelength, RF carrier frequency and optical path is experimentally demonstrated. The system is able to do the switching processes correctly, while achieving BER values below FEC limit....

  8. Utility of Ambulance Data for Real-Time Syndromic Surveillance: A Pilot in the West Midlands Region, United Kingdom.

    Science.gov (United States)

    Todkill, Dan; Loveridge, Paul; Elliot, Alex J; Morbey, Roger A; Edeghere, Obaghe; Rayment-Bishop, Tracy; Rayment-Bishop, Chris; Thornes, John E; Smith, Gillian

    2017-12-01

    Introduction The Public Health England (PHE; United Kingdom) Real-Time Syndromic Surveillance Team (ReSST) currently operates four national syndromic surveillance systems, including an emergency department system. A system based on ambulance data might provide an additional measure of the "severe" end of the clinical disease spectrum. This report describes the findings and lessons learned from the development and preliminary assessment of a pilot syndromic surveillance system using ambulance data from the West Midlands (WM) region in England. Hypothesis/Problem Is an Ambulance Data Syndromic Surveillance System (ADSSS) feasible and of utility in enhancing the existing suite of PHE syndromic surveillance systems? An ADSSS was designed, implemented, and a pilot conducted from September 1, 2015 through March 1, 2016. Surveillance cases were defined as calls to the West Midlands Ambulance Service (WMAS) regarding patients who were assigned any of 11 specified chief presenting complaints (CPCs) during the pilot period. The WMAS collected anonymized data on cases and transferred the dataset daily to ReSST, which contained anonymized information on patients' demographics, partial postcode of patients' location, and CPC. The 11 CPCs covered a broad range of syndromes. The dataset was analyzed descriptively each week to determine trends and key epidemiological characteristics of patients, and an automated statistical algorithm was employed daily to detect higher than expected number of calls. A preliminary assessment was undertaken to assess the feasibility, utility (including quality of key indicators), and timeliness of the system for syndromic surveillance purposes. Lessons learned and challenges were identified and recorded during the design and implementation of the system. The pilot ADSSS collected 207,331 records of individual ambulance calls (daily mean=1,133; range=923-1,350). The ADSSS was found to be timely in detecting seasonal changes in patterns of respiratory

  9. Use of Jigsaw Technique to Teach the Unit "Science within Time" in Secondary 7th Grade Social Sciences Course and Students' Views on This Technique

    Science.gov (United States)

    Yapici, Hakki

    2016-01-01

    The aim of this study is to apply the jigsaw technique in Social Sciences teaching and to unroll the effects of this technique on learning. The unit "Science within Time" in the secondary 7th grade Social Sciences text book was chosen for the research. It is aimed to compare the jigsaw technique with the traditional teaching method in…

  10. Circadian-Time Sickness: Time-of-Day Cue-Conflicts Directly Affect Health.

    Science.gov (United States)

    van Ee, Raymond; Van de Cruys, Sander; Schlangen, Luc J M; Vlaskamp, Björn N S

    2016-11-01

    A daily rhythm that is not in synchrony with the environmental light-dark cycle (as in jetlag and shift work) is known to affect mood and health through an as yet unresolved neural mechanism. Here, we combine Bayesian probabilistic 'cue-conflict' theory with known physiology of the biological clock of the brain, entailing the insight that, for a functional pacemaker, it is sufficient to have two interacting units (reflecting environmental and internal time-of-day cues), without the need for an extra homuncular directing unit. Unnatural light-dark cycles cause a time-of-day cue-conflict that is reflected by a desynchronization between the ventral (environmental) and dorsal (internal) pacemaking signals of the pacemaker. We argue that this desynchronization, in-and-of-itself, produces health issues that we designate as 'circadian-time sickness', analogous to 'motion sickness'. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Time flies faster under time pressure.

    Science.gov (United States)

    Rattat, Anne-Claire; Matha, Pauline; Cegarra, Julien

    2018-04-01

    We examined the effects of time pressure on duration estimation in a verbal estimation task and a production task. In both temporal tasks, participants had to solve mazes in two conditions of time pressure (with or without), and with three different target durations (30 s, 60 s, and 90 s). In each trial of the verbal estimation task, participants had to estimate in conventional time units (minutes and seconds) the amount of time that had elapsed since they started to solve the maze. In the production task, they had to press a key while solving the maze when they thought that the trial's duration had reached a target value. Results showed that in both tasks, durations were judged longer with time pressure than without it. However, this temporal overestimation under time pressure did not increase with the length of the target duration. These results are discussed within the framework of scalar expectancy theory. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Volumization of the Brow at the Time of Blepharoplasty: Treating the Eyebrow Fat Pad as an Independent Unit.

    Science.gov (United States)

    Vrcek, Ivan; Chou, Eva; Somogyi, Marie; Shore, John W

    Loss of volume in the sub-brow fat pad with associated descent of the eyebrow is a common anatomical finding resulting in both functional and aesthetic consequences. A variety of techniques have been described to address brow position at the time of blepharoplasty. To our knowledge, none of these techniques treat the sub-brow fat pad as an isolated unit. Doing so enables the surgeon to stabilize and volumize the brow without resultant tension on the blepharoplasty wound. The authors describe a technique for addressing volume loss in the eyebrow with associated brow descent that treats the sub-brow fat pad as an isolated unit. A retrospective review of all patients undergoing brow ptosis repair by a single surgeon (J.W.S.) over an 11-month period was performed. Eighteen patients and 33 brows underwent the technique described. Patients were followed for an average of 11 weeks (range: 4 weeks to 20 weeks). All patients preoperatively displayed both visually significant dermatochalasis and brow descent below the orbital rim. Evaluation of pre- and postoperative photos demonstrates successful volumization of the brow with skin redraping without focal dimpling or undue tension on the eyelid wound. Performing a dissection that allows the sub-brow fat pad to be elevated in isolation from the overlying orbicularis and underlying periosteum allows for volumization and of the brow without compromising closure. This technique is a safe and effective means of volumizing the brow and treating secondary brow descent.

  13. Stochastic behavior of a cold standby system with maximum repair time

    Directory of Open Access Journals (Sweden)

    Ashish Kumar

    2015-09-01

    Full Text Available The main aim of the present paper is to analyze the stochastic behavior of a cold standby system with concept of preventive maintenance, priority and maximum repair time. For this purpose, a stochastic model is developed in which initially one unit is operative and other is kept as cold standby. There is a single server who visits the system immediately as and when required. The server takes the unit under preventive maintenance after a maximum operation time at normal mode if one standby unit is available for operation. If the repair of the failed unit is not possible up to a maximum repair time, failed unit is replaced by new one. The failure time, maximum operation time and maximum repair time distributions of the unit are considered as exponentially distributed while repair and maintenance time distributions are considered as arbitrary. All random variables are statistically independent and repairs are perfect. Various measures of system effectiveness are obtained by using the technique of semi-Markov process and RPT. To highlight the importance of the study numerical results are also obtained for MTSF, availability and profit function.

  14. An automatic control unit for A neutron diffraction crystal spectrometer

    International Nuclear Information System (INIS)

    Adib, M.; Abbas, Y.; Mostafa, M.; Hamouda, I.

    1982-01-01

    An automatic transistorized unit has been designed and constructed to control the operation of the double axis crystal spectrometer installed in front of one of the horizontal channels of the ET-RR-1 reactor. The function of the automatic unit is to store the diffracted neutrons at a certain angle with respect to the direction of the incident neutron beam in a selected channel of a 1024-multichannel analyzer for a certain preadjusted time period. AT the end of this time period the unit rotates the spectrometer's arm to another angle, selects the next channel of the MCA and provides the measurement of the diffracted neutron for the same time period. Such a sequence is repeated automatically over all angles required for the neutron diffraction pattern of the sample under investigation. As a result, the stored information at the MCA provides the neutron diffraction pattern as a function of channel number, where each channel corresponds to a certain scattering angle. The stored distribution at MCA can be obtained through the analyzer read out unit. The designed automatic unit has the possibility of providing the neutron diffraction pattern using a 6-digit scaler and a printer

  15. Matching soil grid unit resolutions with polygon unit scales for DNDC modelling of regional SOC pool

    Science.gov (United States)

    Zhang, H. D.; Yu, D. S.; Ni, Y. L.; Zhang, L. M.; Shi, X. Z.

    2015-03-01

    Matching soil grid unit resolution with polygon unit map scale is important to minimize uncertainty of regional soil organic carbon (SOC) pool simulation as their strong influences on the uncertainty. A series of soil grid units at varying cell sizes were derived from soil polygon units at the six map scales of 1:50 000 (C5), 1:200 000 (D2), 1:500 000 (P5), 1:1 000 000 (N1), 1:4 000 000 (N4) and 1:14 000 000 (N14), respectively, in the Tai lake region of China. Both format soil units were used for regional SOC pool simulation with DeNitrification-DeComposition (DNDC) process-based model, which runs span the time period 1982 to 2000 at the six map scales, respectively. Four indices, soil type number (STN) and area (AREA), average SOC density (ASOCD) and total SOC stocks (SOCS) of surface paddy soils simulated with the DNDC, were attributed from all these soil polygon and grid units, respectively. Subjecting to the four index values (IV) from the parent polygon units, the variation of an index value (VIV, %) from the grid units was used to assess its dataset accuracy and redundancy, which reflects uncertainty in the simulation of SOC. Optimal soil grid unit resolutions were generated and suggested for the DNDC simulation of regional SOC pool, matching with soil polygon units map scales, respectively. With the optimal raster resolution the soil grid units dataset can hold the same accuracy as its parent polygon units dataset without any redundancy, when VIV indices was assumed as criteria to the assessment. An quadratic curve regression model y = -8.0 × 10-6x2 + 0.228x + 0.211 (R2 = 0.9994, p < 0.05) was revealed, which describes the relationship between optimal soil grid unit resolution (y, km) and soil polygon unit map scale (1:x). The knowledge may serve for grid partitioning of regions focused on the investigation and simulation of SOC pool dynamics at certain map scale.

  16. Designing and evaluating an automated system for real-time medication administration error detection in a neonatal intensive care unit.

    Science.gov (United States)

    Ni, Yizhao; Lingren, Todd; Hall, Eric S; Leonard, Matthew; Melton, Kristin; Kirkendall, Eric S

    2018-05-01

    Timely identification of medication administration errors (MAEs) promises great benefits for mitigating medication errors and associated harm. Despite previous efforts utilizing computerized methods to monitor medication errors, sustaining effective and accurate detection of MAEs remains challenging. In this study, we developed a real-time MAE detection system and evaluated its performance prior to system integration into institutional workflows. Our prospective observational study included automated MAE detection of 10 high-risk medications and fluids for patients admitted to the neonatal intensive care unit at Cincinnati Children's Hospital Medical Center during a 4-month period. The automated system extracted real-time medication use information from the institutional electronic health records and identified MAEs using logic-based rules and natural language processing techniques. The MAE summary was delivered via a real-time messaging platform to promote reduction of patient exposure to potential harm. System performance was validated using a physician-generated gold standard of MAE events, and results were compared with those of current practice (incident reporting and trigger tools). Physicians identified 116 MAEs from 10 104 medication administrations during the study period. Compared to current practice, the sensitivity with automated MAE detection was improved significantly from 4.3% to 85.3% (P = .009), with a positive predictive value of 78.0%. Furthermore, the system showed potential to reduce patient exposure to harm, from 256 min to 35 min (P patient exposure to potential harm following MAE events.

  17. Real-time performance assessment and adaptive control for a water chiller unit in an HVAC system

    Science.gov (United States)

    Bai, Jianbo; Li, Yang; Chen, Jianhao

    2018-02-01

    The paper proposes an adaptive control method for a water chiller unit in a HVAC system. Based on the minimum variance evaluation, the adaptive control method was used to realize better control of the water chiller unit. To verify the performance of the adaptive control method, the proposed method was compared with an a conventional PID controller, the simulation results showed that adaptive control method had superior control performance to that of the conventional PID controller.

  18. Amplitude and rise time compensated timing optimized for large semiconductor detectors

    International Nuclear Information System (INIS)

    Kozyczkowski, J.J.; Bialkowski, J.

    1976-01-01

    The ARC timing described has excellent timing properties even when using a wide range e.g. from 10 keV to over 1 MeV. The detector signal from a preamplifier is accepted directly by the unit as a timing filter amplifier with a sensitivity of 1 mV is incorporated. The adjustable rise time rejection feature makes it possible to achieve a good prompt time spectrum with symmetrical exponential shape down to less than 1/100 of the peak value. A complete block diagram of the unit is given together with results of extensive tests of its performance. For example the time spectrum for (1330+-20) keV of 60 Co taken with a 43 cm 3 Ge(Li) detector has the following parameters: fwhm = 2.2ns, fwtm = 4.4 ns and fw (0.01) m = 7.6 ns and for (50 +- 10) keV of 22 Na the following was obtained: fwhm = 10.8 ns, fwtm = 21.6 ns and fw (0.01) m = 34.6 ns. In another experiment with two fast plastic scintillations (NE 102A) and using a 20% dynamic energy range the following was measured: fwhm = 280 ps, fwtm = 470 ps and fw (0.01) m = 70ps. (Auth.)

  19. Quality control of diagnostic x-ray units

    International Nuclear Information System (INIS)

    Marinkovic, O.; Milacic, S.; Jovicic, D.; Tanaskovic, I.

    2001-01-01

    The quality control program for diagnostic x-ray units has started at the Institute of Occupational and Radiological Health during 1990. It includes, among other measurements, reproducibility of dose, high voltage and exposure time. Dose reproducibility was less than 5% for 70% of tested x-ray units. The exposure time and high voltage reproducibility were less than 5% in 60% cases. The cassettes with amplifying foils made from components of rare earth are used in 10% of all x-ray departments. It is very important to work as much as it is possible to modernize general infrastructure as the radiological protection of patients would be better. (author)

  20. Dynamic reliability networks with self-healing units

    International Nuclear Information System (INIS)

    Jenab, K.; Seyed Hosseini, S.M.; Dhillon, B.S.

    2008-01-01

    This paper presents an analytical approach for dynamic reliability networks used for the failure limit strategy in maintenance optimization. The proposed approach utilizes the moment generating function (MGF) and the flow-graph concept to depict the functional and reliability diagrams of the system comprised of series, parallel or mix configuration of self-healing units. The self-healing unit is featured by the embedded failure detection and recovery mechanisms presented by self-loop in flow-graph networks. The newly developed analytical approach provides the probability of the system failure and time-to-failure data i.e., mean and standard deviation time-to-failure used for maintenance optimization

  1. Estimates of the timing of reductions in genital warts and high grade cervical intraepithelial neoplasia after onset of human papillomavirus (HPV) vaccination in the United States.

    Science.gov (United States)

    Chesson, Harrell W; Ekwueme, Donatus U; Saraiya, Mona; Dunne, Eileen F; Markowitz, Lauri E

    2013-08-20

    The objective of this study was to estimate the number of years after onset of a quadrivalent HPV vaccination program before notable reductions in genital warts and cervical intraepithelial neoplasia (CIN) will occur in teenagers and young adults in the United States. We applied a previously published model of HPV vaccination in the United States and focused on the timing of reductions in genital warts among both sexes and reductions in CIN 2/3 among females. Using different coverage scenarios, the lowest being consistent with current 3-dose coverage in the United States, we estimated the number of years before reductions of 10%, 25%, and 50% would be observed after onset of an HPV vaccination program for ages 12-26 years. The model suggested female-only HPV vaccination in the intermediate coverage scenario will result in a 10% reduction in genital warts within 2-4 years for females aged 15-19 years and a 10% reduction in CIN 2/3 among females aged 20-29 years within 7-11 years. Coverage had a major impact on when reductions would be observed. For example, in the higher coverage scenario a 25% reduction in CIN2/3 would be observed with 8 years compared with 15 years in the lower coverage scenario. Our model provides estimates of the potential timing and magnitude of the impact of HPV vaccination on genital warts and CIN 2/3 at the population level in the United States. Notable, population-level impacts of HPV vaccination on genital warts and CIN 2/3 can occur within a few years after onset of vaccination, particularly among younger age groups. Our results are generally consistent with early reports of declines in genital warts among youth. Published by Elsevier Ltd.

  2. A recursive framework for time-dependent characteristics of tested and maintained standby units with arbitrary distributions for failures and repairs

    International Nuclear Information System (INIS)

    Vaurio, Jussi K.

    2015-01-01

    The time-dependent unavailability and the failure and repair intensities of periodically tested aging standby system components are solved with recursive equations under three categories of testing and repair policies. In these policies, tests or repairs or both can be minimal or perfect renewals. Arbitrary distributions are allowed to times to failure as well as to repair and renewal durations. Major preventive maintenance is done periodically or at random times, e.g. when a true demand occurs. In the third option process renewal is done if a true demand occurs or when a certain mission time has expired since the previous maintenance, whichever occurs first. A practical feature is that even if a repair can renew the unit, it does not generally renew the alternating process. The formalism updates and extends earlier results by using a special backward-renewal equation method, by allowing scheduled tests not limited to equal intervals and accepting arbitrary distributions and multiple failure types and causes, including failures caused by tests, human errors and true demands. Explicit solutions are produced to integral equations associated with an age-renewal maintenance policy. - Highlights: • Time-dependent unavailability, failure count and repair count for a standby system. • Free testing schedule and distributions for times to failure, repair and maintenance. • Multiple failure modes; tests or repairs or both can be minimal or perfect renewals. • Process renewals periodically, randomly or based on the process age or an initiator. • Backward renewal equations as explicit solutions to Volterra-type integral equations

  3. New steam generators slated for nuclear units

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This article is a brief discussion of Duke Power's plans to replace steam generators at its McGuire and Catawba nuclear units. A letter of intent to purchase (from Babcock and Wilcox) the 12 Westinghouse steam generators has been signed, but no constructor has been selected at this time. This action is brought about by the failures of more than 3000 tubes in these units

  4. Using Lean principles to manage throughput on an inpatient rehabilitation unit.

    Science.gov (United States)

    Chiodo, Anthony; Wilke, Ruste; Bakshi, Rishi; Craig, Anita; Duwe, Doug; Hurvitz, Edward

    2012-11-01

    Performance improvement is a mainstay of operations management and maintenance of certification. In this study at a University Hospital inpatient rehabilitation unit, Lean management techniques were used to manage throughput of patients into and out of the inpatient rehabilitation unit. At the start of this process, the average admission time to the rehabilitation unit was 5:00 p.m., with a median time of 3:30 p.m., and no patients received therapy on the day of admission. Within 8 mos, the mean admission time was 1:22 p.m., 50% of the patients were on the rehabilitation unit by 1:00 p.m., and more than 70% of all patients received therapy on the day of admission. Negative variance from this performance was evaluated, the identification of inefficient discharges holding up admissions as a problem was identified, and a Lean workshop was initiated. Once this problem was tackled, the prime objective of 70% of patients receiving therapy on the date of admission was consistently met. Lean management tools are effective in improving throughput on an inpatient rehabilitation unit.

  5. Wound Botulism in Injection Drug Users: Time to Antitoxin Correlates with Intensive Care Unit Length of Stay

    Directory of Open Access Journals (Sweden)

    Offerman, Steven R

    2009-11-01

    Full Text Available Objectives: We sought to identify factors associated with need for mechanical ventilation (MV, length of intensive care unit (ICU stay, length of hospital stay, and poor outcome in injection drug users (IDUs with wound botulism (WB.Methods: This is a retrospective review of WB patients admitted between 1991-2005. IDUs were included if they had symptoms of WB and diagnostic confirmation. Primary outcome variables were the need for MV, length of ICU stay, length of hospital stay, hospital-related complications, and death.Results: Twenty-nine patients met inclusion criteria. Twenty-two (76% admitted to heroin use only and seven (24% admitted to heroin and methamphetamine use. Chief complaints on initial presentation included visual changes, 13 (45%; weakness, nine (31%; and difficulty swallowing, seven (24%. Skin wounds were documented in 22 (76%. Twenty-one (72% patients underwent mechanical ventilation (MV. Antitoxin (AT was administered to 26 (90% patients but only two received antitoxin in the emergency department (ED. The time from ED presentation to AT administration was associated with increased length of ICU stay (Regression coefficient = 2.5; 95% CI 0.45, 4.5. The time from ED presentation to wound drainage was also associated with increased length of ICU stay (Regression coefficient = 13.7; 95% CI = 2.3, 25.2. There was no relationship between time to antibiotic administration and length of ICU stay.Conclusion: MV and prolonged ICU stays are common in patients identified with WB. Early AT administration and wound drainage are recommended as these measures may decrease ICU length of stay.[West J Emerg Med. 2009;10(4:251-256.

  6. Field demonstrations of radon adsorption units

    International Nuclear Information System (INIS)

    Abrams, R.F.

    1989-01-01

    Four radon gas removal units have been installed in homes in the Northeast U.S. These units utilize dynamic adsorption of the radon gas onto activated charcoal to remove the radon from room air. Two beds of charcoal are used so that one bed removes radon while the second bed is regenerated using outdoor air in a unique process. The beds reverse at the end of a predetermined cycle time, providing continuous removal of radon from the room air. The process and units have undergone extensive development work in the laboratory as well as in homes and a summary of this work is discussed. This work showed that the system performs very effectively over a range of operating conditions similar to those found in a home. The field test data that is presented shows that scale up from the laboratory work was without problem and the units are functioning as expected. This unit provides homeowners and mitigation contractors with another option to solve the radon gas problem in homes, particularly in homes that it is difficult to prevent radon from entering

  7. Academic Outcome Measures of a Dedicated Education Unit Over Time: Help or Hinder?

    Science.gov (United States)

    Smyer, Tish; Gatlin, Tricia; Tan, Rhigel; Tejada, Marianne; Feng, Du

    2015-01-01

    Critical thinking, nursing process, quality and safety measures, and standardized RN exit examination scores were compared between students (n = 144) placed in a dedicated education unit (DEU) and those in a traditional clinical model. Standardized test scores showed that differences between the clinical groups were not statistically significant. This study shows that the DEU model is 1 approach to clinical education that can enhance students' academic outcomes.

  8. Ultrasonic unit for line-by-line ultrasonic scanning of bodies

    International Nuclear Information System (INIS)

    Soldner, R.

    1978-01-01

    The ultrasonic unit for medical diagnostics operates by the sectorial scanning principle, which avoids direct coupling of the transducer head to the surface of the body. For this purpose, several transmitter/receiver units (approx. 100) are arranged on a partial ring of a circular arc and the ultrasonic beams, which can be triggered sequentially in time, are directed at a common intersection behind the ultrasonic window of the unit, i.e., outside the unit. A mechanical system is employed to set and adjust the partial ring carrying the transmitter/receiver units. (DG) [de

  9. Evaluating perceptual integration: uniting response-time- and accuracy-based methodologies.

    Science.gov (United States)

    Eidels, Ami; Townsend, James T; Hughes, Howard C; Perry, Lacey A

    2015-02-01

    This investigation brings together a response-time system identification methodology (e.g., Townsend & Wenger Psychonomic Bulletin & Review 11, 391-418, 2004a) and an accuracy methodology, intended to assess models of integration across stimulus dimensions (features, modalities, etc.) that were proposed by Shaw and colleagues (e.g., Mulligan & Shaw Perception & Psychophysics 28, 471-478, 1980). The goal was to theoretically examine these separate strategies and to apply them conjointly to the same set of participants. The empirical phases were carried out within an extension of an established experimental design called the double factorial paradigm (e.g., Townsend & Nozawa Journal of Mathematical Psychology 39, 321-359, 1995). That paradigm, based on response times, permits assessments of architecture (parallel vs. serial processing), stopping rule (exhaustive vs. minimum time), and workload capacity, all within the same blocks of trials. The paradigm introduced by Shaw and colleagues uses a statistic formally analogous to that of the double factorial paradigm, but based on accuracy rather than response times. We demonstrate that the accuracy measure cannot discriminate between parallel and serial processing. Nonetheless, the class of models supported by the accuracy data possesses a suitable interpretation within the same set of models supported by the response-time data. The supported model, consistent across individuals, is parallel and has limited capacity, with the participants employing the appropriate stopping rule for the experimental setting.

  10. Transfusional profile in different types of intensive care units

    Directory of Open Access Journals (Sweden)

    Ilusca Cardoso de Paula

    2014-06-01

    Full Text Available Background and objectives: anemia is a common clinical finding in intensive care units. The red blood cell transfusion is the main form of treatment, despite the associated risks. Thus, we proposed to evaluate the profile of transfusional patients in different intensive care units. Methods: prospective analysis of patients admitted in the intensive care units of a tertiary university hospital with an indication for transfusion of packed red blood cells. Demographic profile and transfusional profile were collected, a univariate analysis was done, and the results were considered significant at p = 0.05. Results: 408 transfusions were analyzed in 71 patients. The mean hemoglobin concentration on admission was 9.7 ± 2.3 g/dL and the pre-transfusional concentration was 6.9 ± 1.1 g/dL. The main indications for transfusion were hemoglobin concentration (49% and active bleeding (32%. The median number of units transfused per episode was 2 (1-2 and the median storage time was 14 (7-21 days. The number of patients transfused with hemoglobin levels greater than 7 g/dL and the number of bags transfused per episode were significantly different among intensive care units. Patients who received three or more transfusions had longer mechanical ventilation time and intensive care unit stay and higher mortality after 60 days. There was an association of mortality with disease severity but not with transfusional characteristics. Conclusions: the practice of blood products transfusion was partially in agreement with the guidelines recommended, although there are differences in behavior between the different profiles of intensive care units. Transfused patients evolved with unfavorable outcomes. Despite the scarcity of blood in blood banks, the mean storage time of the bags was high.

  11. The metrology of time.

    Science.gov (United States)

    Arias, Elisa Felicitas

    2005-09-15

    Measuring time is a continuous activity, an international and restless enterprise hidden in time laboratories spread all over the planet. The Bureau International des Poids et Mesures is charged with coordinating activities for international timekeeping and it makes use of the world's capacity to produce a remarkably stable and accurate reference time-scale. Commercial atomic clocks beating the second in national laboratories can reach a stability of one part in 10(14) over a 5 day averaging time, compelling us to research the most highly performing methods of remote clock comparison. The unit of the international time-scale is the second of the International System of Units, realized with an uncertainty of the order 10(-15) by caesium fountains. Physicists in a few time laboratories are making efforts to gain one order of magnitude in the uncertainty of the realization of the second, and more refined techniques of time and frequency transfer are in development to accompany this progress. Femtosecond comb technology will most probably contribute in the near future to enhance the definition of the second with the incorporation of optical clocks. We will explain the evolution of the measuring of time, current state-of-the-art measures and future challenges.

  12. Design of a memory-access controller with 3.71-times-enhanced energy efficiency for Internet-of-Things-oriented nonvolatile microcontroller unit

    Science.gov (United States)

    Natsui, Masanori; Hanyu, Takahiro

    2018-04-01

    In realizing a nonvolatile microcontroller unit (MCU) for sensor nodes in Internet-of-Things (IoT) applications, it is important to solve the data-transfer bottleneck between the central processing unit (CPU) and the nonvolatile memory constituting the MCU. As one circuit-oriented approach to solving this problem, we propose a memory access minimization technique for magnetoresistive-random-access-memory (MRAM)-embedded nonvolatile MCUs. In addition to multiplexing and prefetching of memory access, the proposed technique realizes efficient instruction fetch by eliminating redundant memory access while considering the code length of the instruction to be fetched and the transition of the memory address to be accessed. As a result, the performance of the MCU can be improved while relaxing the performance requirement for the embedded MRAM, and compact and low-power implementation can be performed as compared with the conventional cache-based one. Through the evaluation using a system consisting of a general purpose 32-bit CPU and embedded MRAM, it is demonstrated that the proposed technique increases the peak efficiency of the system up to 3.71 times, while a 2.29-fold area reduction is achieved compared with the cache-based one.

  13. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Hun [Kaya University, Gimhae (Korea, Republic of); Im, In Chul [Gwangju Health College University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Chosun University, Gwangju (Korea, Republic of); Kang, Se Sik [College of Health Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2009-03-15

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  14. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    International Nuclear Information System (INIS)

    Park, Ju Hun; Im, In Chul; Dong, Kyung Rae; Kang, Se Sik

    2009-01-01

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  15. The Full-Time Workweek in the United States, 1900-1970

    Science.gov (United States)

    Kniesner, Thomas J.

    1976-01-01

    The average workweek of full-time workers declined by 35 percent between 1900 and 1940, but has not changed significnatly since then, and the secular rigidity of the full-time workweek remains. An expanded model which incorporates the effects of growth in education and in the female wage explains the post-1940 secular trend. (Editor/HD)

  16. The PAMELA storage and control unit

    International Nuclear Information System (INIS)

    Casolino, M.; Altamura, F.; Basili, A.; De Pascale, M.P.; Minori, M.; Nagni, M.; Picozza, P.; Sparvoli, R.; Adriani, O.; Papini, P.; Spillantini, P.; Castellini, G.; Boezio, M.

    2007-01-01

    The PAMELA Storage and Control Unit (PSCU) comprises a Central Processing Unit (CPU) and a Mass Memory (MM). The CPU of the experiment is based on a ERC-32 architecture (a SPARC v7 implementation) running a real time operating system (RTEMS). The main purpose of the CPU is to handle slow control, acquisition and store data on a 2 GB MM. Communications between PAMELA and the satellite are done via a 1553B bus. Data acquisition from the sub-detectors is performed via a 2 MB/s interface. Download from the PAMELA MM towards the satellite main storage unit is handled by a 16 MB/s bus. The maximum daily amount of data transmitted to ground is about 20 GB

  17. The PAMELA storage and control unit

    Energy Technology Data Exchange (ETDEWEB)

    Casolino, M. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy)]. E-mail: Marco.Casolino@roma2.infn.it; Altamura, F. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Basili, A. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); De Pascale, M.P. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Minori, M. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Nagni, M. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Picozza, P. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Sparvoli, R. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Adriani, O. [INFN, Structure of Florence, Physics Department, University of Florence, I-50019 Sesto Fiorentino (Italy); Papini, P. [INFN, Structure of Florence, Physics Department, University of Florence, I-50019 Sesto Fiorentino (Italy); Spillantini, P. [INFN, Structure of Florence, Physics Department, University of Florence, I-50019 Sesto Fiorentino (Italy); Castellini, G. [CNR-Istituto di Fisica Applicata ' Nello Carrara' , I-50127 Florence (Italy); Boezio, M. [INFN, Structure of Trieste, Physics Department, University of Trieste, I-34147 Trieste (Italy)

    2007-03-01

    The PAMELA Storage and Control Unit (PSCU) comprises a Central Processing Unit (CPU) and a Mass Memory (MM). The CPU of the experiment is based on a ERC-32 architecture (a SPARC v7 implementation) running a real time operating system (RTEMS). The main purpose of the CPU is to handle slow control, acquisition and store data on a 2 GB MM. Communications between PAMELA and the satellite are done via a 1553B bus. Data acquisition from the sub-detectors is performed via a 2 MB/s interface. Download from the PAMELA MM towards the satellite main storage unit is handled by a 16 MB/s bus. The maximum daily amount of data transmitted to ground is about 20 GB.

  18. Unit Testing for Command and Control Systems

    Science.gov (United States)

    Alexander, Joshua

    2018-01-01

    Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.

  19. Effect of nocturnal sound reduction on the incidence of delirium in intensive care unit patients: An interrupted time series analysis.

    Science.gov (United States)

    van de Pol, Ineke; van Iterson, Mat; Maaskant, Jolanda

    2017-08-01

    Delirium in critically-ill patients is a common multifactorial disorder that is associated with various negative outcomes. It is assumed that sleep disturbances can result in an increased risk of delirium. This study hypothesized that implementing a protocol that reduces overall nocturnal sound levels improves quality of sleep and reduces the incidence of delirium in Intensive Care Unit (ICU) patients. This interrupted time series study was performed in an adult mixed medical and surgical 24-bed ICU. A pre-intervention group of 211 patients was compared with a post-intervention group of 210 patients after implementation of a nocturnal sound-reduction protocol. Primary outcome measures were incidence of delirium, measured by the Intensive Care Delirium Screening Checklist (ICDSC) and quality of sleep, measured by the Richards-Campbell Sleep Questionnaire (RCSQ). Secondary outcome measures were use of sleep-inducing medication, delirium treatment medication, and patient-perceived nocturnal noise. A significant difference in slope in the percentage of delirium was observed between the pre- and post-intervention periods (-3.7% per time period, p=0.02). Quality of sleep was unaffected (0.3 per time period, p=0.85). The post-intervention group used significantly less sleep-inducing medication (psound-reduction protocol. However, reported sleep quality did not improve. Copyright © 2017. Published by Elsevier Ltd.

  20. An Optimization Method of Time Window Based on Travel Time and Reliability

    OpenAIRE

    Fu, Fengjie; Ma, Dongfang; Wang, Dianhai; Qian, Wei

    2015-01-01

    The dynamic change of urban road travel time was analyzed using video image detector data, and it showed cyclic variation, so the signal cycle length at the upstream intersection was conducted as the basic unit of time window; there was some evidence of bimodality in the actual travel time distributions; therefore, the fitting parameters of the travel time bimodal distribution were estimated using the EM algorithm. Then the weighted average value of the two means was indicated as the travel t...

  1. Extending total parenteral nutrition hang time in the neonatal intensive care unit: is it safe and cost effective?

    Science.gov (United States)

    Balegar V, Kiran Kumar; Azeem, Mohammad Irfan; Spence, Kaye; Badawi, Nadia

    2013-01-01

    To investigate the effects of prolonging hang time of total parenteral nutrition (TPN) fluid on central line-associated blood stream infection (CLABSI), TPN-related cost and nursing workload. A before-after observational study comparing the practice of hanging TPN bags for 48 h (6 February 2009-5 February 2010) versus 24 h (6 February 2008-5 February 2009) in a tertiary neonatal intensive care unit was conducted. The main outcome measures were CLABSI, TPN-related expenses and nursing workload. One hundred thirty-six infants received 24-h TPN bags and 124 received 48-h TPN bags. Median (inter-quartile range) gestation (37 weeks (33,39) vs. 36 weeks (33,39)), mean (±standard deviation) admission weight of 2442 g (±101) versus 2476 g (±104) and TPN duration (9.7 days (±12.7) vs. 9.9 days (±13.4)) were similar (P > 0.05) between the 24- and 48-h TPN groups. There was no increase in CLABSI with longer hang time (0.8 vs. 0.4 per 1000 line days in the 24-h vs. 48-h group; P < 0.05). Annual cost saving using 48-h TPN was AUD 97,603.00. By using 48-h TPN, 68.3% of nurses indicated that their workload decreased and 80.5% indicated that time spent changing TPN reduced. Extending TPN hang time from 24 to 48 h did not alter CLABSI rate and was associated with a reduced TPN-related cost and perceived nursing workload. Larger randomised controlled trials are needed to more clearly delineate these effects. © 2012 The Authors. Journal of Paediatrics and Child Health © 2012 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  2. Physical time scale in kinetic Monte Carlo simulations of continuous-time Markov chains.

    Science.gov (United States)

    Serebrinsky, Santiago A

    2011-03-01

    We rigorously establish a physical time scale for a general class of kinetic Monte Carlo algorithms for the simulation of continuous-time Markov chains. This class of algorithms encompasses rejection-free (or BKL) and rejection (or "standard") algorithms. For rejection algorithms, it was formerly considered that the availability of a physical time scale (instead of Monte Carlo steps) was empirical, at best. Use of Monte Carlo steps as a time unit now becomes completely unnecessary.

  3. Nations United: The United Nations, the United States, and the Global Campaign Against Terrorism. A Curriculum Unit & Video for Secondary Schools.

    Science.gov (United States)

    Houlihan, Christina; McLeod, Shannon

    This curriculum unit and 1-hour videotape are designed to help students understand the purpose and functions of the United Nations (UN) and explore the relationship between the United Nations and the United States. The UN's role in the global counterterrorism campaign serves as a case study for the unit. The students are asked to develop a basic…

  4. Generation of flat wideband chaos with suppressed time delay signature by using optical time lens.

    Science.gov (United States)

    Jiang, Ning; Wang, Chao; Xue, Chenpeng; Li, Guilan; Lin, Shuqing; Qiu, Kun

    2017-06-26

    We propose a flat wideband chaos generation scheme that shows excellent time delay signature suppression effect, by injecting the chaotic output of general external cavity semiconductor laser into an optical time lens module composed of a phase modulator and two dispersive units. The numerical results demonstrate that by properly setting the parameters of the driving signal of phase modulator and the accumulated dispersion of dispersive units, the relaxation oscillation in chaos can be eliminated, wideband chaos generation with an efficient bandwidth up to several tens of GHz can be achieved, and the RF spectrum of generated chaotic signal is nearly as flat as uniform distribution. Moreover, the periodicity of chaos induced by the external cavity modes can be simultaneously destructed by the optical time lens module, based on this the time delay signature can be completely suppressed.

  5. 31 CFR 515.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...

  6. 31 CFR 500.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 500.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including U.S. trust territories...

  7. 31 CFR 535.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...

  8. Two service units with interference in the access to servers

    Directory of Open Access Journals (Sweden)

    Rosa E. Lillo

    1999-01-01

    Full Text Available We examine the service mechanism of two queueing models with two units in tandem. In the first model, customers who complete service in Unit 1 must wait in an intermediate buffer until the ongoing service in Unit II ends. In the second model, jobs can be pre-positioned in an intermediate buffer to await service in Unit II. Under the assumption of phase-type service times, the steady-state regime of the service system is studied in detail.

  9. Microcontroller based four-channel current readout unit for beam slit monitor

    International Nuclear Information System (INIS)

    Holikatti, A.C.; Puntambekar, T.A.; Pithawa, C.K.

    2009-01-01

    This paper describes the design and development of a microcontroller based four-channel current readout unit for Beam Slit Monitor (BSM) installed in Transport Line-1 of Indus Accelerator Complex. BSM is a diagnostic device consisting of two horizontal and two vertical blades, which can be moved independently in to the beam pipe to cut the beam transversely. The readout unit employs switched integrators with reset, hold and select switches and timing and control unit. It integrates the current output of the four blades of BSM and produces an output corresponding to the beam charge intercepted by the blade. The integrator outputs are then multiplexed and digitized using 12-bit ADC. Acquired digital data from ADC is stored into on-chip RAM of the microcontroller. The readout sequence is synchronized with the Microtron beam-timing signal. The timing of integration, hold and reset cycles is controlled by the microcontroller. The unit is connected on a serial link to the host computer in main control room. This unit has been integrated with the BSM system and is being used to obtain the electron beam profile. (author)

  10. Generation and prediction of time series by a neural network

    International Nuclear Information System (INIS)

    Eisenstein, E.; Kanter, I.; Kessler, D.A.; Kinzel, W.

    1995-01-01

    Generation and prediction of time series are analyzed for the case of a bit generator: a perceptron where in each time step the input units are shifted one bit to the right with the state of the leftmost input unit set equal to the output unit in the previous time step. The long-time dynamical behavior of the bit generator consists of cycles whose typical period scales polynomially with the size of the network and whose spatial structure is periodic with a typical finite wavelength. The generalization error on a cycle is zero for a finite training set, and global dynamical behaviors can also be learned in a finite time. Hence, a projection of a rule can be learned in a finite time

  11. Effect of light-curing units, post-cured time and shade of resin cement on knoop hardness.

    Science.gov (United States)

    Reges, Rogério Vieira; Costa, Ana Rosa; Correr, Américo Bortolazzo; Piva, Evandro; Puppin-Rontani, Regina Maria; Sinhoreti, Mário Alexandre Coelho; Correr-Sobrinho, Lourenço

    2009-01-01

    The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the catalyst paste and inserted into a black Teflon mold (5 mm diameter x 1 mm high). A transparent strip was placed over the mold and a ceramic disc (Duceram Plus, shade A3) was positioned over the resin cement. Light-activation was performed through the ceramic for 40 s using quartz-tungsten-halogen (QTH) (XL 2500; 3M ESPE) or light-emitting diode (LED) (Ultrablue Is, DMC) LCUs with power density of 615 and 610 mW/cm(2), respectively. The Koop hardness was measured using a microhardness tester HMV 2 (Shimadzu) after 15 min or 24 h. Four indentations were made in each specimen. Data were subjected to ANOVA and Tukey's test (alpha=0.05). The QTH LCU provided significantly higher (pcement showed lower Knoop hardness than the other shades for both LCUs and post-cure times.

  12. Development of a Real-Time Thermal Performance Diagnostic Monitoring system Using Self-Organizing Neural Network for Kori-2 Nuclear Power Unit

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Seong, Poong Hyun

    1996-01-01

    In this work, a PC-based thermal performance monitoring system is developed for the nuclear power plants. the system performs real-time thermal performance monitoring and diagnosis during plant operation. Specifically, a prototype for the Kori-2 nuclear power unit is developed and examined is very difficult because the system structure is highly complex and the components are very much inter-related. In this study, some major diagnostic performance parameters are selected in order to represent the thermal cycle effectively and to reduce the computing time. The Fuzzy ARTMAP, a self-organizing neural network, is used to recognize the characteristic pattern change of the performance parameters in abnormal situation. By examination, the algorithm is shown to be ale to detect abnormality and to identify the fault component or the change of system operation condition successfully. For the convenience of operators, a graphical user interface is also constructed in this work. 5 figs., 3 tabs., 11 refs. (Author)

  13. Nearly Efficient Likelihood Ratio Tests for Seasonal Unit Roots

    DEFF Research Database (Denmark)

    Jansson, Michael; Nielsen, Morten Ørregaard

    In an important generalization of zero frequency autore- gressive unit root tests, Hylleberg, Engle, Granger, and Yoo (1990) developed regression-based tests for unit roots at the seasonal frequencies in quarterly time series. We develop likelihood ratio tests for seasonal unit roots and show...... that these tests are "nearly efficient" in the sense of Elliott, Rothenberg, and Stock (1996), i.e. that their local asymptotic power functions are indistinguishable from the Gaussian power envelope. Currently available nearly efficient testing procedures for seasonal unit roots are regression-based and require...... the choice of a GLS detrending parameter, which our likelihood ratio tests do not....

  14. Food irradiation in the United States

    International Nuclear Information System (INIS)

    Pauli, G.H.

    1991-01-01

    Since 1963, some irradiated foods have been permitted for sale in the United States. Yet, at this time, commercial application has been limited to irradiation of a relatively small fraction of the spices and seasonings used as ingredients in other foods. The current situation regarding irradiated foods in the United States and how it developed is discussed. The author writes from experience gained as a Government regulator concerned primarily with ensuring safety of food and therefore this is stressed together with the crucial role played by consumers and industry. (author)

  15. The influence of floc size and hydraulic detention time on the performance of a dissolved air flotation (DAF) pilot unit in the light of a mathematical model.

    Science.gov (United States)

    Moruzzi, R B; Reali, M A P

    2014-12-01

    The influence of floc size and hydraulic detention time on the performance of a dissolved air flotation (DAF) pilot unit was investigated in the light of a known mathematical model. The following design and operational parameters were considered: the hydraulic detention time (tdcz) and hydraulic loading rate in the contact zone, the down-flow loading rate in the clarification zone, the particle size distribution (d F), and the recirculation rate (p). As a reference for DAF performance analysis, the proposed β.td parameter from the above mentioned mathematical model was employed. The results indicated that tdcz is an important factor in DAF performance and that d F and floc size are also determinants of DAF efficiency. Further, β.td was sensitive to both design and operational parameters, which were varied in the DAF pilot plant. The performance of the DAF unit decreases with increasing β.td values because a higher td (considering a fixed β) or a higher β (e.g., higher hydrophobicity of the flocs for a fixed td) would be necessary in the reaction zone to reach desired flotation efficiency.

  16. Decreased Stress Levels in Nurses: A Benefit of Quiet Time.

    Science.gov (United States)

    Riemer, Heather C; Mates, Joanna; Ryan, Linda; Schleder, Bonnie J

    2015-09-01

    The benefits of quiet time, a therapeutic method of improving the health care environment, have been evaluated in patients, but only a few studies have examined the effects of quiet time on intensive care nurses. To evaluate the effects of implementing quiet time in a medical-surgical intensive care unit on levels of light, noise, and nurses' stress. Quiet time consisted of turning down the unit lights for a designated time. Levels of light, noise, and nurses' stress were measured. Nurses' stress levels were measured by using a 100-point visual analog scale; unit noise, by using a digital sound level meter (model 407736, Extech Instruments); and unit light, by using an illumination light meter (model 615, Huygen Corporation). Measurements were obtained 30 minutes before and 30 minutes, 1 hour, and 2 hours after implementation of quiet time. Analysis of variance and comparisons of means indicated that both light levels and nurses' stress levels were significantly decreased after quiet time (both P quiet time, but the decrease was not significant (P = .08). Use of quiet time resulted in decreased light levels and decreased stress levels among nurses. Quiet time is an easily performed energy-saving intervention to promote a healthy work environment. ©2015 American Association of Critical-Care Nurses.

  17. Reduction in the volume of water for ingesting orally disintegrating tablets of solifenacin (Vesicare® OD), and the clinical disintegration time of Vesicare® OD after unit-dose packaging.

    Science.gov (United States)

    Uchida, Shinya; Yoshita, Tomohiro; Namiki, Noriyuki

    2013-03-25

    This study aimed to determine the amount of water required for ingesting an orally disintegrating tablet (ODT) of solifenacin (Vesicare(®), VES) and VES conventional tablets (VES-CT). We measured the disintegration time of VES-ODT in the oral cavity (clinical disintegration time) before and after unit-dose packaging. Thirty healthy volunteers participated in this randomized crossover trial. The participants were asked to drink water during the intake placebos of VES and after the disintegration of placebos of VES-ODT in their oral cavity. The amounts of water required for ingesting placebos of VES-CT and of VES-ODT were 42.8±27.0 mL and 20.0±23.7 mL, respectively, which indicated that the amount of water required for ingesting ODTs was significantly lesser than that for ingesting CTs. Furthermore, 5 (16.7%) participants did not require water for ingesting the ODTs. Clinical disintegration time of VES-ODT was 21.4s in 10 healthy volunteers. This clinical disintegration time did not change significantly after unit-dose packaging or subsequent storage for 56 days. This study showed that the amount of water required for ingesting VES-ODT is lower than that for ingesting VES-CT. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  18. Validating Timed Component Contracts

    DEFF Research Database (Denmark)

    Le Guilly, Thibaut; Liu, Shaoying; Olsen, Petur

    2015-01-01

    This paper presents a technique for testing software components with contracts that specify functional behavior, synchronization, as well as timing behavior. The approach combines elements from unit testing with model-based testing techniques for timed automata. The technique is implemented...... in an online testing tool, and we demonstrate its use on a concrete use case....

  19. Changes in patient safety culture after restructuring of intensive care units: Two cross-sectional studies.

    Science.gov (United States)

    Vifladt, Anne; Simonsen, Bjoerg O; Lydersen, Stian; Farup, Per G

    2016-02-01

    Compare changes in registered nurses' perception of the patient safety culture in restructured and not restructured intensive care units during a four-year period. Two cross-sectional surveys were performed, in 2008/2009 (time 1) and 2012/2013 (time 2). During a period of 0-3 years after time 1, three of six hospitals merged their general and medical intensive care units (restructured). The other hospitals maintained their structure of the intensive care units (not restructured). Intensive care units in hospitals at one Norwegian hospital trust. The safety culture was measured with Hospital Survey on Patient Safety Culture. At times 1 and 2, 217/302 (72%) and 145/289 (50%) registered nurses participated. Restructuring was negatively associated with change in the safety culture, in particular, the dimensions of the safety culture within the unit level. The dimensions most vulnerable for restructuring were manager expectations and actions promoting safety, teamwork within hospital units and staffing. In this study, the restructuring of intensive care units was associated with a negative impact on the safety culture. When restructuring, the management should be particularly aware of changes in the safety culture dimensions manager expectations and actions promoting safety, teamwork within hospital units and staffing. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Legionella spp. in dental unit waterlines.

    Science.gov (United States)

    Sedlata Juraskova, E; Sedlackova, H; Janska, J; Holy, O; Lalova, I; Matouskova, I

    2017-01-01

    To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc. The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2). From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella. Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).

  1. Application of enhanced discrete differential evolution approach to unit commitment problem

    International Nuclear Information System (INIS)

    Yuan Xiaohui; Su Anjun; Nie Hao; Yuan Yanbin; Wang Liang

    2009-01-01

    This paper proposes a discrete binary differential evolution (DBDE) approach to solve the unit commitment problem (UCP). The proposed method is enhanced by priority list based on the unit characteristics and heuristic search strategies to handle constraints effectively. The implementation of the proposed method for UCP consists of three stages. Firstly, the DBDE based on priority list is applied for unit scheduling when neglecting the minimum up/down time constraints. Secondly, repairing strategies are used to handle the minimum up/down time constraints and decommit excess spinning reserve units. Finally, heuristic unit substitution search and gray zone modification algorithm are used to improve optimal solution further. Furthermore, the effects of two crucial parameters on performance of the DBDE for solving UCP are studied as well. To verify the advantages of the method, the proposed method is tested and compared to the other methods on the systems with the number of units in the range of 10-100. Numerical results demonstrate that the proposed method is superior to other methods reported in the literature.

  2. The Proximate Unit in Chinese Handwritten Character Production

    Directory of Open Access Journals (Sweden)

    Jenn-Yeu eChen

    2013-08-01

    Full Text Available In spoken word production, a proximate unit is the first phonological unit at the sublexical level that is selectable for production (O’Seaghdha, Chen, & Chen, 2010. The present study investigated whether the proximate unit in Chinese handwritten word production is the stroke, the radical, or something in between. A written version of the form preparation task was adopted. Chinese participants learned sets of two-character words, later were cued with the first character of each word, and had to write down the second character (the target. Response times were measured from the onset of a cue character to the onset of a written response. In Experiment 1, the target characters within a block shared (homogeneous or did not share (heterogeneous the first stroke. In Experiment 2, the first two strokes were shared in the homogeneous blocks. Response times in the homogeneous blocks and in the heterogeneous blocks were comparable in both experiments (Exp. 1: 687 ms vs. 684 ms, Exp. 2: 717 vs. 716. In Experiment 3 and 4, the target characters within a block shared or did not share the first radical. Response times in the homogeneous blocks were significantly faster than those in the heterogeneous blocks (Exp. 3: 685 vs. 704, Exp. 4: 594 vs. 650. In Experiment 5 and 6, the shared component was a Gestalt-like form that is more than a stroke, constitutes a portion of the target character, can be a stand-alone character itself, can be a radical of another character but is not a radical of the target character (e.g., 士in聲, 鼓, 穀, 款; called a logographeme. Response times in the homogeneous blocks were significantly faster than those in the heterogeneous blocks (Exp. 5: 576 vs. 625, Exp. 6: 586 vs. 620. These results suggest a model of Chinese handwritten character production in which the stroke is not a functional unit, the radical plays the role of a morpheme, and the logographeme is the proximate unit.

  3. A RWMAC commentary on the Science Policy Research Unit report: UK nuclear decommissioning policy: time for decision

    International Nuclear Information System (INIS)

    1994-04-01

    Chapter 4 of the RWMAC's Twelfth Annual Report discussed nuclear power plant decommissioning strategy. One of the RWMAC's conclusions was that the concept of financial provisioning for power station decommissioning liabilities, which might be passed on to society several generations into the future, deserved further study. A specification for such a study was duly written (Annex 2) and, following consideration of tendered responses, the Science Policy Research Unit (SPRU) at Sussex University, was contracted to carry out the work. The SPRU report stands as a SPRU analysis of the subject. This separate short RWMAC report, which is being released at the same time as the SPRU report, presents the RWMAC's own commentary on the SPRU study. The RWMAC has identified five main issues which should be addressed when deciding on a nuclear plant decommissioning strategy. These are: the technical approach to decommissioning, the basis of financial provisions, treatment of risk, segregation of management of funds, and the need for a wider environmental view. These issues are addressed in this RWMAC report. (author)

  4. 49 CFR 236.790 - Release, time.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Release, time. 236.790 Section 236.790... Release, time. A device used to prevent the operation of an operative unit until after the expiration of a predetermined time interval after the device has been actuated. ...

  5. Investigation of clinical conditions affecting quality control in a dental X-ray unit

    International Nuclear Information System (INIS)

    Akiyama, Hironori; Koseki, Takakazu; Itagaki, Keisuke; Yotsui, Yoritaka; Gamoh, Shoko; Shimizutani, Kimishige

    2011-01-01

    In this study, to clarify quality control issues in a dental X-ray unit, we surveyed the uniformity and safety of absorbed doses and exposure time from dental X-ray units, and evaluated image quality of intraoral radiography at Osaka Dental University Hospital. Measurements of dose and exposure time were carried out five times and the mean was calculated at twenty-two dental X-ray units in our university hospital using the standard parameters for the mandibular molar region in adults. Intraoral radiography for evaluation of image quality was taken using D-speed films under the standard parameters for the mandibular molar region in adults and E-speed films for pediatric patients. Evaluation of image quality was performed by three oral radiologists. Dose and exposure time differed significantly among units. Image quality of intraoral radiography using D-speed films was not significantly better than that of E-speed films. This study demonstrated that it is necessary to establish a uniform dose and exposure time and to change D-speed films to E-speed films when obtaining intraoral radiography in our hospital. (author)

  6. Management of planned unit outages

    International Nuclear Information System (INIS)

    Brune, W.

    1984-01-01

    Management of planned unit outages at the Bruno Leuschner Nuclear Power Plant is based on the experience gained with Soviet PWR units of the WWER type over a period of more than 50 reactor-years. For PWR units, planned outages concentrate almost exclusively on annual refuellings and major maintenance of the power plant facilities involved. Planning of such major maintenance work is based on a standardized basic network plan and a catalogue of standardized maintenance and inspection measures. From these, an overall maintenance schedule of the unit and partial process plans of the individual main components are derived (manually or by computer) and, in the temporal integration of major maintenance at every unit, fixed starting times and durations are determined. More than 75% of the maintenance work at the Bruno Leuschner Nuclear Power Plant is carried out by the plant's own maintenance personnel. Large-scale maintenance of every unit is controlled by a special project head. He is assisted by commissioners, each of whom is responsible for his own respective item. A daily control report is made. The organizational centre is a central office which works in shifts around the clock. All maintenance orders and reports of completion pass through this office; thus, the overall maintenance schedule can be corrected daily. To enforce the proposed operational strategy, suitable accompanying technical measures are required with respect to effective facility monitoring and technical diagnosis, purposeful improvement of particularly sensitive components and an increase in the effectiveness of maintenance work by special technologies and devices. (author)

  7. 29 CFR 1919.71 - Unit proof test and examination of cranes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...

  8. 5 CFR 630.207 - Travel time.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Travel time. 630.207 Section 630.207... and General Provisions for Annual and Sick Leave § 630.207 Travel time. The travel time granted an employee under section 6303(d) of title 5, United States Code, is inclusive of the time necessarily...

  9. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  10. Adjustments differ among low-threshold motor units during intermittent, isometric contractions.

    Science.gov (United States)

    Farina, Dario; Holobar, Ales; Gazzoni, Marco; Zazula, Damjan; Merletti, Roberto; Enoka, Roger M

    2009-01-01

    We investigated the changes in muscle fiber conduction velocity, recruitment and derecruitment thresholds, and discharge rate of low-threshold motor units during a series of ramp contractions. The aim was to compare the adjustments in motor unit activity relative to the duration that each motor unit was active during the task. Multichannel surface electromyographic (EMG) signals were recorded from the abductor pollicis brevis muscle of eight healthy men during 12-s contractions (n = 25) in which the force increased and decreased linearly from 0 to 10% of the maximum. The maximal force exhibited a modest decline (8.5 +/- 9.3%; P motor units that were active for 16-98% of the time during the first five contractions were identified throughout the task by decomposition of the EMG signals. Action potential conduction velocity decreased during the task by a greater amount for motor units that were initially active for >70% of the time compared with that of less active motor units. Moreover, recruitment and derecruitment thresholds increased for these most active motor units, whereas the thresholds decreased for the less active motor units. Another 18 motor units were recruited at an average of 171 +/- 32 s after the beginning of the task. The recruitment and derecruitment thresholds of these units decreased during the task, but muscle fiber conduction velocity did not change. These results indicate that low-threshold motor units exhibit individual adjustments in muscle fiber conduction velocity and motor neuron activation that depended on the relative duration of activity during intermittent contractions.

  11. Timing in a FLASH

    Science.gov (United States)

    Hoek, M.; Cardinali, M.; Corell, O.; Dickescheid, M.; Ferretti B., M. I.; Lauth, W.; Schlimme, B. S.; Sfienti, C.; Thiel, M.

    2017-12-01

    A prototype detector, called FLASH (Fast Light Acquiring Start Hodoscope), was built to provide precise Time-of-Flight (TOF) measurements and reference timestamps for detector setups at external beam lines. Radiator bars, made of synthetic fused silica, were coupled to a fast MCP-PMT with 64 channels and read out with custom electronics using Time-over-Threshold (TOT) for signal characterization. The TRB3 system, a high-precision TDC implemented in an FPGA, was used as data acquisition system. The performance of a system consisting of two FLASH units was investigated at a dedicated test experiment at the Mainz Microtron (MAMI) accelerator using its 855 MeV electron beam. The TOT measurement enabled time walk corrections and an overall TOF resolution of ∼70 ps could be achieved which translates into a resolution of ∼50 ps per FLASH unit. The intrinsic resolution of the frontend electronics including the TDC was measured to be less than 25 ps.

  12. Results of the first detection units of KM3NeT

    Science.gov (United States)

    Biagi, Simone; KM3NeT Collaboration

    2017-12-01

    The KM3NeT collaboration is building a km3-scale neutrino telescope in the Mediterranean Sea. The current phase of construction comprises the deep-sea and onshore infrastructures at two installation sites and the installation of the first detection units for the "ARCA" (Astroparticle Research with Cosmics in the Abyss) and "ORCA" (Oscillation Research with Cosmics in the Abyss) detector. At the KM3NeT-It site, 80 km offshore Capo Passero, Italy, the first 32 detection units for the ARCA detector are being installed and at the KM3Net-Fr site, 40 km offshore Toulon, France, 7 detection units for the ORCA detector will be deployed. The second phase of KM3NeT foresees the completion of ARCA for neutrino astronomy at energies above TeV and ORCA for neutrino mass hierarchy studies at energies in the GeV range. The basic element of the KM3NeT detector is the detection unit. In the ARCA geometry, the detection unit is a 700 m long vertical structure hosting 18 optical modules. Each optical module comprises 31 3 in photomultiplier tubes, instruments to monitor environmental parameters, and the electronic boards for the digitisation of the PMT signals and the management of data acquisition. In their final configuration, both ARCA and ORCA will be composed of about 200 detection units. The first detection unit was installed at the KM3NeT-It site in December 2015. It is active and taking data since its connection to the subsea network. The time of arrival and the duration of photon hits on each of the photomultipliers is measured with a time resolution of 1 ns and transferred onshore where the measurements are processed, triggered and stored on disk. A time calibration procedure, based on data recorded with flashing LED beacons during dedicated periods, allows for time synchronisation of the signals from the optical modules at the nanosecond level. In May 2016, an additional detection unit was installed at the KM3NeT-It site. The first results with two active detection units

  13. Atmospheric Nitrogen Deposition in the Western United States: Sources, Sinks and Changes over Time

    Science.gov (United States)

    Anderson, Sarah Marie

    Anthropogenic activities have greatly modified the way nitrogen moves through the atmosphere and terrestrial and aquatic environments. Excess reactive nitrogen generated through fossil fuel combustion, industrial fixation, and intensification of agriculture is not confined to anthropogenic systems but leaks into natural ecosystems with consequences including acidification, eutrophication, and biodiversity loss. A better understanding of where excess nitrogen originates and how that changes over time is crucial to identifying when, where, and to what degree environmental impacts occur. A major route into ecosystems for excess nitrogen is through atmospheric deposition. Excess nitrogen is emitted to the atmosphere where it can be transported great distances before being deposited back to the Earth's surface. Analyzing the composition of atmospheric nitrogen deposition and biological indicators that reflect deposition can provide insight into the emission sources as well as processes and atmospheric chemistry that occur during transport and what drives variation in these sources and processes. Chapter 1 provides a review and proof of concept of lichens to act as biological indicators and how their elemental and stable isotope composition can elucidate variation in amounts and emission sources of nitrogen over space and time. Information on amounts and emission sources of nitrogen deposition helps inform natural resources and land management decisions by helping to identify potentially impacted areas and causes of those impacts. Chapter 2 demonstrates that herbaria lichen specimens and field lichen samples reflect historical changes in atmospheric nitrogen deposition from urban and agricultural sources across the western United States. Nitrogen deposition increases throughout most of the 20 th century because of multiple types of emission sources until the implementation of the Clean Air Act Amendments of 1990 eventually decrease nitrogen deposition around the turn of

  14. Analytical Call Center Model with Voice Response Unit and Wrap-Up Time

    Directory of Open Access Journals (Sweden)

    Petr Hampl

    2015-01-01

    Full Text Available The last twenty years of computer integration significantly changed the process of service in a call center service systems. Basic building modules of classical call centers – a switching system and a group of humans agents – was extended with other special modules such as skills-based routing module, automatic call distribution module, interactive voice response module and others to minimize the customer waiting time and wage costs. A calling customer of a modern call center is served in the first stage by the interactive voice response module without any human interaction. If the customer requirements are not satisfied in the first stage, the service continues to the second stage realized by the group of human agents. The service time of second stage – the average handle time – is divided into a conversation time and wrap-up time. During the conversation time, the agent answers customer questions and collects its requirements and during the wrap-up time (administrative time the agent completes the task without any customer interaction. The analytical model presented in this contribution is solved under the condition of statistical equilibrium and takes into account the interactive voice response module service time, the conversation time and the wrap-up time.

  15. Motorcycle trends in the United States

    Science.gov (United States)

    2009-05-01

    During the last decade there has been a significant increase in the number of motorcycle sales and registrations in the United States. At the same time there has been a shift in the demographics of motorcycle users and increased focus on motorcycle s...

  16. Simulation and optimization of an industrial PSA unit

    Directory of Open Access Journals (Sweden)

    Barg C.

    2000-01-01

    Full Text Available The Pressure Swing Adsorption (PSA units have been used as a low cost alternative to the usual gas separation processes. Its largest commercial application is for hydrogen purification systems. Several studies have been made about the simulation of pressure swing adsorption units, but there are only few reports on the optimization of such processes. The objective of this study is to simulate and optimize an industrial PSA unit for hydrogen purification. This unit consists of six beds, each of them have three layers of different kinds of adsorbents. The main impurities are methane, carbon monoxide and sulfidric gas. The product stream has 99.99% purity in hydrogen, and the recovery is around 90%. A mathematical model for a commercial PSA unit is developed. The cycle time and the pressure swing steps are optimized. All the features concerning with complex commercial processes are considered.

  17. Analysis of operating reliability of WWER-1000 unit

    International Nuclear Information System (INIS)

    Bortlik, J.

    1985-01-01

    The nuclear power unit was divided into 33 technological units. Input data for reliability analysis were surveys of operating results obtained from the IAEA information system and certain indexes of the reliability of technological equipment determined using the Bayes formula. The missing reliability data for technological equipment were used from the basic variant. The fault tree of the WWER-1000 unit was determined for the peak event defined as the impossibility of reaching 100%, 75% and 50% of rated power. The period was observed of the nuclear power plant operation with reduced output owing to defect and the respective time needed for a repair of the equipment. The calculation of the availability of the WWER-1000 unit was made for different variant situations. Certain indexes of the operating reliability of the WWER-1000 unit which are the result of a detailed reliability analysis are tabulated for selected variants. (E.S.)

  18. Non-Relative Value Unit-Generating Activities Represent One-Fifth of Academic Neuroradiologist Productivity.

    Science.gov (United States)

    Wintermark, M; Zeineh, M; Zaharchuk, G; Srivastava, A; Fischbein, N

    2016-07-01

    A neuroradiologist's activity includes many tasks beyond interpreting relative value unit-generating imaging studies. Our aim was to test a simple method to record and quantify the non-relative value unit-generating clinical activity represented by consults and clinical conferences, including tumor boards. Four full-time neuroradiologists, working an average of 50% clinical and 50% academic activity, systematically recorded all the non-relative value unit-generating consults and conferences in which they were involved during 3 months by using a simple, Web-based, computer-based application accessible from smartphones, tablets, or computers. The number and type of imaging studies they interpreted during the same period and the associated relative value units were extracted from our billing system. During 3 months, the 4 neuroradiologists working an average of 50% clinical activity interpreted 4241 relative value unit-generating imaging studies, representing 8152 work relative value units. During the same period, they recorded 792 non-relative value unit-generating study reviews as part of consults and conferences (not including reading room consults), representing 19% of the interpreted relative value unit-generating imaging studies. We propose a simple Web-based smartphone app to record and quantify non-relative value unit-generating activities including consults, clinical conferences, and tumor boards. The quantification of non-relative value unit-generating activities is paramount in this time of a paradigm shift from volume to value. It also represents an important tool for determining staffing levels, which cannot be performed on the basis of relative value unit only, considering the importance of time spent by radiologists on non-relative value unit-generating activities. It may also influence payment models from medical centers to radiology departments or practices. © 2016 by American Journal of Neuroradiology.

  19. Does size matter? Animal units and animal unit months

    Science.gov (United States)

    Lamar Smith; Joe Hicks; Scott Lusk; Mike Hemmovich; Shane Green; Sarah McCord; Mike Pellant; John Mitchell; Judith Dyess; Jim Sprinkle; Amanda Gearhart; Sherm Karl; Mike Hannemann; Ken Spaeth; Jason Karl; Matt Reeves; Dave Pyke; Jordan Spaak; Andrew Brischke; Del Despain; Matt Phillippi; Dave Weixelmann; Alan Bass; Jessie Page; Lori Metz; David Toledo; Emily Kachergis

    2017-01-01

    The concepts of animal units, animal unit months, and animal unit equivalents have long been used as standards for range management planning, estimating stocking rates, reporting actual use, assessing grazing fees, ranch appraisal, and other purposes. Increasing size of cattle on rangelands has led some to suggest that the definition of animal units and animal unit...

  20. Architectural design proposal for real time clock for wireless microcontroller unit

    Science.gov (United States)

    Alias, Muhammad Nor Azwan Mohd; Nizam Mohyar, Shaiful

    2017-11-01

    In this project, we are developing an Intellectual properties (IP) which is a dedicated real-time clock (RTC) system for a wireless microcontroller. This IP is developed using Verilog Hardware Description Language (Verilog HDL) and being simulated using Quartus II and Synopsys software. This RTC will be used in microcontroller system to provide precise time and date which can be used for various applications. It plays a very important role in the real-time systems like digital clock, attendance system, digital camera and more.

  1. Architectural design proposal for real time clock for wireless microcontroller unit

    Directory of Open Access Journals (Sweden)

    Mohd Alias Muhammad Nor Azwan

    2017-01-01

    Full Text Available In this project, we are developing an Intellectual properties (IP which is a dedicated real-time clock (RTC system for a wireless microcontroller. This IP is developed using Verilog Hardware Description Language (Verilog HDL and being simulated using Quartus II and Synopsys software. This RTC will be used in microcontroller system to provide precise time and date which can be used for various applications. It plays a very important role in the real-time systems like digital clock, attendance system, digital camera and more.

  2. Cobalt Blues The Story of Leonard Grimmett, the Man Behind the First Cobalt-60 Unit in the United States

    CERN Document Server

    Almond, Peter R

    2013-01-01

    For the latter half of the 20th century, cobalt-60 units were the mainstay of radiation treatments for cancer. Cobalt Blues describes the development of the first cobalt-60 unit in the United States and the man behind it, Leonard Grimmett. Conceptually conceived before World War II, it only became possible because of the development of nuclear reactors during the war. Although Grimmett conceived of and published his ideas first, the Canadians built the first units because of the capability of their reactor to produce more suitable cobalt-60 sources. This book tells the story of how Grimmett and others came together at the time that the U S Atomic Energy Agency was pushing the use of radioactivity in medicine. Due to his sudden death, very little information about Grimmett was known until recently, when various documents have come to light, allowing the full story to be told.

  3. Rapanos v. United States & Carabell v. United States

    Science.gov (United States)

    Documents associated with guidance for implementing the definition of waters of the United States under the Clean Water Act following the Rapanos v. United States, and Carabell v. United States Supreme Court decision.

  4. Political initiative needed in the United States

    International Nuclear Information System (INIS)

    Hollister, K.

    1979-01-01

    The financing of nuclear power stations in the United States is in trouble mainly because of the long lead times caused by licensing. It will again become feasible when legislation reduces the construction time to eight years or less. The overriding need to protect the dollar by reducing oil imports, will lead the US Government to embrace nuclear power openly. (U.K.)

  5. Park availability and physical activity, TV time, and overweight and obesity among women: Findings from Australia and the United States.

    Science.gov (United States)

    Veitch, Jenny; Abbott, Gavin; Kaczynski, Andrew T; Wilhelm Stanis, Sonja A; Besenyi, Gina M; Lamb, Karen E

    2016-03-01

    This study examined relationships between three measures of park availability and self-reported physical activity (PA), television viewing (TV) time, and overweight/obesity among women from Australia and the United States. Having more parks near home was the only measure of park availability associated with an outcome. Australian women (n=1848) with more parks near home had higher odds of meeting PA recommendations and lower odds of being overweight/obese. In the US sample (n=489), women with more parks near home had lower odds of watching >4h TV per day. A greater number of parks near home was associated with lower BMI among both Australian and US women. Evidence across diverse contexts provides support to improve park availability to promote PA and other health behaviors. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. A real-time material control concept for safeguarding special nuclear material in United States licensed processing facilities

    International Nuclear Information System (INIS)

    Shea, T.E.

    1976-01-01

    This paper describes general safeguards research being undertaken by the United States Nuclear Regulatory Commission. Efforts to improve the ability of United States licensed plants to contend with the perceived threat of covert material theft are emphasized. The framework for this improvement is to break down the internal control and accounting system into subsystems to achieve material isolation, inventory control, inventory characterization, and inventory containment analysis. A general programme is outlined to develop and evaluate appropriate mechanisms, integrate selected mechanisms into subsystems, and evaluate the subsystems in the context of policy requirements. (author)

  7. Laser color recording unit

    Science.gov (United States)

    Jung, E.

    1984-05-01

    A color recording unit was designed for output and control of digitized picture data within computer controlled reproduction and picture processing systems. In order to get a color proof picture of high quality similar to a color print, together with reduced time and material consumption, a photographic color film material was exposed pixelwise by modulated laser beams of three wavelengths for red, green and blue light. Components of different manufacturers for lasers, acousto-optic modulators and polygon mirrors were tested, also different recording methods as (continuous tone mode or screened mode and with a drum or flatbed recording principle). Besides the application for the graphic arts - the proof recorder CPR 403 with continuous tone color recording with a drum scanner - such a color hardcopy peripheral unit with large picture formats and high resolution can be used in medicine, communication, and satellite picture processing.

  8. The LCLS Timing Event System

    Energy Technology Data Exchange (ETDEWEB)

    Dusatko, John; Allison, S.; Browne, M.; Krejcik, P.; /SLAC

    2012-07-23

    The Linac Coherent Light Source requires precision timing trigger signals for various accelerator diagnostics and controls at SLAC-NAL. A new timing system has been developed that meets these requirements. This system is based on COTS hardware with a mixture of custom-designed units. An added challenge has been the requirement that the LCLS Timing System must co-exist and 'know' about the existing SLC Timing System. This paper describes the architecture, construction and performance of the LCLS timing event system.

  9. Radiation incidents with a cobalt-60 teletherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R G; Tolbert, D D; Pailwal, B R; Radtke, R R [Wisconsin Univ., Madison (USA). Dept. of Radiology

    1976-08-01

    Three radiation incidents associated with source drive failures on one particular /sup 60/Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of /sup 60/Co teletherapy units to minimise the results of the malfunctioning of such a system are given.

  10. Radiation incidents with a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Lane, R.G.; Tolbert, D.D.; Pailwal, B.R.; Radtke, R.R.

    1976-01-01

    Three radiation incidents associated with source drive failures on one particular 60 Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of 60 Co teletherapy units to minimise the results of the malfunctioning of such a system are given. (U.K.)

  11. Interface unit

    NARCIS (Netherlands)

    Keyson, D.V.; Freudenthal, A.; De Hoogh, M.P.A.; Dekoven, E.A.M.

    2001-01-01

    The invention relates to an interface unit comprising at least a display unit for communication with a user, which is designed for being coupled with a control unit for at least one or more parameters in a living or working environment, such as the temperature setting in a house, which control unit

  12. Time-constrained project scheduling with adjacent resources

    NARCIS (Netherlands)

    Hurink, Johann L.; Kok, A.L.; Paulus, J.J.; Schutten, Johannes M.J.

    We develop a decomposition method for the Time-Constrained Project Scheduling Problem (TCPSP) with adjacent resources. For adjacent resources the resource units are ordered and the units assigned to a job have to be adjacent. On top of that, adjacent resources are not required by single jobs, but by

  13. Time-constrained project scheduling with adjacent resources

    NARCIS (Netherlands)

    Hurink, Johann L.; Kok, A.L.; Paulus, J.J.; Schutten, Johannes M.J.

    2008-01-01

    We develop a decomposition method for the Time-Constrained Project Scheduling Problem (TCPSP) with Adjacent Resources. For adjacent resources the resource units are ordered and the units assigned to a job have to be adjacent. On top of that, adjacent resources are not required by single jobs, but by

  14. History and measurement of the base and derived units

    CERN Document Server

    Treese, Steven A

    2018-01-01

    This book discusses how and why historical measurement units developed, and reviews useful methods for making conversions as well as situations in which dimensional analysis can be used. It starts from the history of length measurement, which is one of the oldest measures used by humans. It highlights the importance of area measurement, briefly discussing the methods for determining areas mathematically and by measurement. The book continues on to detail the development of measures for volume, mass, weight, time, temperature, angle, electrical units, amounts of substances, and light intensity. The seven SI/metric base units are highlighted, as well as a number of other units that have historically been used as base units. Providing a comprehensive reference for interconversion among the commonly measured quantities in the different measurement systems with engineering accuracy, it also examines the relationships among base units in fields such as mechanical/thermal, electromagnetic and physical flow rates and...

  15. Comparison of the heat generation of light curing units.

    Science.gov (United States)

    Bagis, Bora; Bagis, Yildirim; Ertas, Ertan; Ustaomer, Seda

    2008-02-01

    The aim of this study was to evaluate the heat generation of three different types of light curing units. Temperature increases were recorded from a distance of 1 mm from a thermocouple to the tip of three different types of light curing units including one quartz-tungsten halogen (QTH), one plasma arc (PAC), and one light emitting diode (LED) unit. An experimental model was designed to fix the 1 mm distance between the tip of the light curing units and the thermocouple wire. Temperature changes were recorded in 10 second intervals up to 40 seconds. (10, 20, 30, and 40 seconds). Temperature measurements were repeated three times for every light curing unit after a one hour standby period. Statistical analysis of the results was performed using the analysis of variance (ANOVA) and the Bonferroni Test. The highest temperature rises (54.4+/-1.65 degrees C) occurred during activation of a PAC light curing unit for every test period (pdamage to the pulp.

  16. The Category of Time in English, Russian and French Phraseology

    Directory of Open Access Journals (Sweden)

    Elena A. Makleeva

    2017-09-01

    Full Text Available In the paper we make an attempt to analyze linguistic and cultural descriptions of phraseological units of English, Russian and French reflecting the category of time. In the study of each language about 200 of phraseological units associated with the category of time were taken, which were divided into 5 groups representing different phraseo-semantic concepts. We have carried out a semantic analysis of the data of phraseological units identified by national-cultural peculiarities of expression of time category. The results can be used in the practice of teaching English, Russian and French as foreign languages, in courses on linguistics, and are also taken into account compiling dictionaries.

  17. A Real-Time Accurate Model and Its Predictive Fuzzy PID Controller for Pumped Storage Unit via Error Compensation

    Directory of Open Access Journals (Sweden)

    Jianzhong Zhou

    2017-12-01

    Full Text Available Model simulation and control of pumped storage unit (PSU are essential to improve the dynamic quality of power station. Only under the premise of the PSU models reflecting the actual transient process, the novel control method can be properly applied in the engineering. The contributions of this paper are that (1 a real-time accurate equivalent circuit model (RAECM of PSU via error compensation is proposed to reconcile the conflict between real-time online simulation and accuracy under various operating conditions, and (2 an adaptive predicted fuzzy PID controller (APFPID based on RAECM is put forward to overcome the instability of conventional control under no-load conditions with low water head. Respectively, all hydraulic factors in pipeline system are fully considered based on equivalent lumped-circuits theorem. The pretreatment, which consists of improved Suter-transformation and BP neural network, and online simulation method featured by two iterative loops are synthetically proposed to improve the solving accuracy of the pump-turbine. Moreover, the modified formulas for compensating error are derived with variable-spatial discretization to improve the accuracy of the real-time simulation further. The implicit RadauIIA method is verified to be more suitable for PSUGS owing to wider stable domain. Then, APFPID controller is constructed based on the integration of fuzzy PID and the model predictive control. Rolling prediction by RAECM is proposed to replace rolling optimization with its computational speed guaranteed. Finally, the simulation and on-site measurements are compared to prove trustworthy of RAECM under various running conditions. Comparative experiments also indicate that APFPID controller outperforms other controllers in most cases, especially low water head conditions. Satisfying results of RAECM have been achieved in engineering and it provides a novel model reference for PSUGS.

  18. A RWMAC commentary on the Science Policy Research Unit Report: UK Nuclear Decommissioning Policy: time for decision

    International Nuclear Information System (INIS)

    Anon.

    1994-04-01

    The Radioactive Waste Management Advisory Committee (RWMAC) is an independent body which advises the Secretaries of State for the Environment, Scotland and Wales, on civil radioactive waste management issues. Chapter 4 of the RWMAC's Twelfth Annual Report discussed nuclear power plant decommissioning strategy. One of the RWMAC's conclusions was that the concept of financial provisioning for power station decommissioning liabilities, which might be passed on to society several generations into the future, deserved further study. A specification for such a study was duly written (Annex 2) and, following consideration of tendered responses, the Science Policy Research Unit (SPRU) at Sussex University, was contracted to carry out the work. The SPRU report stands as a SPRU analysis of the subject. This separate short RWMAC report, which is being released at the same time as the SPRU report, presents the RWMAC's own commentary on the SPRU study. The RWMAC has identified five main issues which should be addressed when deciding on a nuclear plant decommissioning strategy. These are: the technical approach to decommissioning, the basis of financial provisions, treatment of risk, segregation of management of funds, and the need for a wider environmental view. (author)

  19. Accuracy, intra- and inter-unit reliability, and comparison between GPS and UWB-based position-tracking systems used for time-motion analyses in soccer.

    Science.gov (United States)

    Bastida Castillo, Alejandro; Gómez Carmona, Carlos D; De la Cruz Sánchez, Ernesto; Pino Ortega, José

    2018-05-01

    There is interest in the accuracy and inter-unit reliability of position-tracking systems to monitor players. Research into this technology, although relatively recent, has grown exponentially in the last years, and it is difficult to find professional team sport that does not use Global Positioning System (GPS) technology at least. The aim of this study is to know the accuracy of both GPS-based and Ultra Wide Band (UWB)-based systems on a soccer field and their inter- and intra-unit reliability. A secondary aim is to compare them for practical applications in sport science. Following institutional ethical approval and familiarization, 10 healthy and well-trained former soccer players (20 ± 1.6 years, 1.76 ± 0.08 cm, and 69.5 ± 9.8 kg) performed three course tests: (i) linear course, (ii) circular course, and (iii) a zig-zag course, all using UWB and GPS technologies. The average speed and distance covered were compared with timing gates and the real distance as references. The UWB technology showed better accuracy (bias: 0.57-5.85%), test-retest reliability (%TEM: 1.19), and inter-unit reliability (bias: 0.18) in determining distance covered than the GPS technology (bias: 0.69-6.05%; %TEM: 1.47; bias: 0.25) overall. Also, UWB showed better results (bias: 0.09; ICC: 0.979; bias: 0.01) for mean velocity measurement than GPS (bias: 0.18; ICC: 0.951; bias: 0.03).

  20. Tracking Single Units in Chronic, Large Scale, Neural Recordings for Brain Machine Interface Applications

    Directory of Open Access Journals (Sweden)

    Ahmed eEleryan

    2014-07-01

    Full Text Available In the study of population coding in neurobiological systems, tracking unit identity may be critical to assess possible changes in the coding properties of neuronal constituents over prolonged periods of time. Ensuring unit stability is even more critical for reliable neural decoding of motor variables in intra-cortically controlled brain-machine interfaces (BMIs. Variability in intrinsic spike patterns, tuning characteristics, and single-unit identity over chronic use is a major challenge to maintaining this stability, requiring frequent daily calibration of neural decoders in BMI sessions by an experienced human operator. Here, we report on a unit-stability tracking algorithm that efficiently and autonomously identifies putative single-units that are stable across many sessions using a relatively short duration recording interval at the start of each session. The algorithm first builds a database of features extracted from units' average spike waveforms and firing patterns across many days of recording. It then uses these features to decide whether spike occurrences on the same channel on one day belong to the same unit recorded on another day or not. We assessed the overall performance of the algorithm for different choices of features and classifiers trained using human expert judgment, and quantified it as a function of accuracy and execution time. Overall, we found a trade-off between accuracy and execution time with increasing data volumes from chronically implanted rhesus macaques, with an average of 12 seconds processing time per channel at ~90% classification accuracy. Furthermore, 77% of the resulting putative single-units matched those tracked by human experts. These results demonstrate that over the span of a few months of recordings, automated unit tracking can be performed with high accuracy and used to streamline the calibration phase during BMI sessions.

  1. Buying time promotes happiness.

    Science.gov (United States)

    Whillans, Ashley V; Dunn, Elizabeth W; Smeets, Paul; Bekkers, Rene; Norton, Michael I

    2017-08-08

    Around the world, increases in wealth have produced an unintended consequence: a rising sense of time scarcity. We provide evidence that using money to buy time can provide a buffer against this time famine, thereby promoting happiness. Using large, diverse samples from the United States, Canada, Denmark, and The Netherlands ( n = 6,271), we show that individuals who spend money on time-saving services report greater life satisfaction. A field experiment provides causal evidence that working adults report greater happiness after spending money on a time-saving purchase than on a material purchase. Together, these results suggest that using money to buy time can protect people from the detrimental effects of time pressure on life satisfaction.

  2. Evaluation of a real-time PCR assay for rectal screening of OXA-48-producing Enterobacteriaceae in a general intensive care unit of an endemic hospital.

    Science.gov (United States)

    Fernández, J; Cunningham, S A; Fernández-Verdugo, A; Viña-Soria, L; Martín, L; Rodicio, M R; Escudero, D; Vazquez, F; Mandrekar, J N; Patel, R

    2017-07-01

    Carbapenemase-producing Enterobacteriaceae are increasing worldwide. Rectal screening for these bacteria can inform the management of infected and colonized patients, especially those admitted to intensive care units (ICUs). A laboratory developed, qualitative duplex real-time polymerase chain reaction assay for rapid detection of OXA-48-like and VIM producing Enterobacteriaceae, performed on rectal swabs, was designed and evaluated in an intensive care unit with endemic presence of OXA-48. During analytical assay validation, no cross-reactivity was observed and 100% sensitivity and specificity were obtained for both bla OXA-48-like and bla VIM in all spiked clinical samples. During the clinical part of the study, the global sensitivity and specificity of the real-time PCR assay for OXA-48 detection were 95.7% and 100% (P=0.1250), respectively, in comparison with culture; no VIM-producing Enterobacteriaceae were detected. Clinical features of patients in the ICU who were colonized or infected with OXA-48 producing Enterobacteriaceae, including outcome, were analyzed. Most had severe underlying conditions, and had risk factors for colonization with carbapenemase-producing Enterobacteriaceae before or during ICU admission, such as receiving previous antimicrobial therapy, prior healthcare exposure (including long-term care), chronic disease, immunosuppression and/or the presence of an intravascular catheter and/or mechanical ventilation device. The described real-time PCR assay is fast (~2-3hours, if DNA extraction is included), simple to perform and results are easy to interpret, features which make it applicable in the routine of clinical microbiology laboratories. Implementation in endemic hospitals could contribute to early detection of patients colonized by OXA-48 producing Enterobacteriaceae and prevention of their spread. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. An evolutionary programming based simulated annealing method for solving the unit commitment problem

    Energy Technology Data Exchange (ETDEWEB)

    Christober Asir Rajan, C. [Department of EEE, Pondicherry Engineering College, Pondicherry 605014 (India); Mohan, M.R. [Department of EEE, Anna University, Chennai 600 025 (India)

    2007-09-15

    This paper presents a new approach to solve the short-term unit commitment problem using an evolutionary programming based simulated annealing method. The objective of this paper is to find the generation scheduling such that the total operating cost can be minimized, when subjected to a variety of constraints. This also means that it is desirable to find the optimal generating unit commitment in the power system for the next H hours. Evolutionary programming, which happens to be a global optimisation technique for solving unit commitment Problem, operates on a system, which is designed to encode each unit's operating schedule with regard to its minimum up/down time. In this, the unit commitment schedule is coded as a string of symbols. An initial population of parent solutions is generated at random. Here, each schedule is formed by committing all the units according to their initial status (''flat start''). Here the parents are obtained from a pre-defined set of solution's, i.e. each and every solution is adjusted to meet the requirements. Then, a random recommitment is carried out with respect to the unit's minimum down times. And SA improves the status. The best population is selected by evolutionary strategy. The Neyveli Thermal Power Station (NTPS) Unit-II in India demonstrates the effectiveness of the proposed approach; extensive studies have also been performed for different power systems consists of 10, 26, 34 generating units. Numerical results are shown comparing the cost solutions and computation time obtained by using the Evolutionary Programming method and other conventional methods like Dynamic Programming, Lagrangian Relaxation and Simulated Annealing and Tabu Search in reaching proper unit commitment. (author)

  4. Mathematical modeling of synthetic unit hydrograph case study: Citarum watershed

    Science.gov (United States)

    Islahuddin, Muhammad; Sukrainingtyas, Adiska L. A.; Kusuma, M. Syahril B.; Soewono, Edy

    2015-09-01

    Deriving unit hydrograph is very important in analyzing watershed's hydrologic response of a rainfall event. In most cases, hourly measures of stream flow data needed in deriving unit hydrograph are not always available. Hence, one needs to develop methods for deriving unit hydrograph for ungagged watershed. Methods that have evolved are based on theoretical or empirical formulas relating hydrograph peak discharge and timing to watershed characteristics. These are usually referred to Synthetic Unit Hydrograph. In this paper, a gamma probability density function and its variant are used as mathematical approximations of a unit hydrograph for Citarum Watershed. The model is adjusted with real field condition by translation and scaling. Optimal parameters are determined by using Particle Swarm Optimization method with weighted objective function. With these models, a synthetic unit hydrograph can be developed and hydrologic parameters can be well predicted.

  5. ENTREPRENEURIAL OPPORTUNITIES IN FOOD PROCESSING UNITS (WITH SPECIAL REFERENCES TO BYADGI RED CHILLI COLD STORAGE UNITS IN THE KARNATAKA STATE

    Directory of Open Access Journals (Sweden)

    P. ISHWARA

    2010-01-01

    Full Text Available After the green revolution, we are now ushering in the evergreen revolution in the country; food processing is an evergreen activity. It is the key to the agricultural sector. In this paper an attempt has been made to study the workings of food processing units with special references to Red Chilli Cold Storage units in the Byadgi district of Karnataka State. Byadgi has been famous for Red Chilli since the days it’s of antiquity. The vast and extensive market yard in Byadagi taluk is famous as the second largest Red Chilli dealing market in the country. However, the most common and recurring problem faced by the farmer is inability to store enough red chilli from one harvest to another. Red chilli that was locally abundant for only a short period of time had to be stored against times of scarcity. In recent years, due to Oleoresin, demand for Red Chilli has grow from other countries like Sri Lanka, Bangladesh, America, Europe, Nepal, Indonesia, Mexico etc. The study reveals that all the cold storage units of the study area have been using vapour compression refrigeration system or method. All entrepreneurs have satisfied with their turnover and profit and they are in a good economic position. Even though the average turnover and profits are increased, few units have shown negligible amount of decrease in turnover and profit. This is due to the competition from increasing number of cold storages and early established units. The cold storages of the study area have been storing Red chilli, Chilli seeds, Chilli powder, Tamarind, Jeera, Dania, Turmeric, Sunflower, Zinger, Channa, Flower seeds etc,. But the 80 per cent of the each cold storage is filled by the red chilli this is due to the existence of vast and extensivered chilli market yard in the Byadgi. There is no business without problems. In the same way the entrepreneurs who are chosen for the study are facing a few problems in their business like skilled labour, technical and management

  6. Travel Time to Hospital for Childbirth: Comparing Calculated Versus Reported Travel Times in France.

    Science.gov (United States)

    Pilkington, Hugo; Prunet, Caroline; Blondel, Béatrice; Charreire, Hélène; Combier, Evelyne; Le Vaillant, Marc; Amat-Roze, Jeanne-Marie; Zeitlin, Jennifer

    2018-01-01

    Objectives Timely access to health care is critical in obstetrics. Yet obtaining reliable estimates of travel times to hospital for childbirth poses methodological challenges. We compared two measures of travel time, self-reported and calculated, to assess concordance and to identify determinants of long travel time to hospital for childbirth. Methods Data came from the 2010 French National Perinatal Survey, a national representative sample of births (N = 14 681). We compared both travel time measures by maternal, maternity unit and geographic characteristics in rural, peri-urban and urban areas. Logistic regression models were used to study factors associated with reported and calculated times ≥30 min. Cohen's kappa coefficients were also calculated to estimate the agreement between reported and calculated times according to women's characteristics. Results In urban areas, the proportion of women with travel times ≥30 min was higher when reported rather than calculated times were used (11.0 vs. 3.6%). Longer reported times were associated with non-French nationality [adjusted odds ratio (aOR) 1.3 (95% CI 1.0-1.7)] and inadequate prenatal care [aOR 1.5 (95% CI 1.2-2.0)], but not for calculated times. Concordance between the two measures was higher in peri-urban and rural areas (52.4 vs. 52.3% for rural areas). Delivery in a specialised level 2 or 3 maternity unit was a principal determinant of long reported and measured times in peri-urban and rural areas. Conclusions for Practice The level of agreement between reported and calculated times varies according to geographic context. Poor measurement of travel time in urban areas may mask problems in accessibility.

  7. Healthy hospital food initiatives in the United States: time to ban sugar sweetened beverages to reduce childhood obesity

    OpenAIRE

    Wojcicki, Janet M

    2013-01-01

    While childhood obesity is a global problem, the extent and severity of the problem in United States, has resulted in a number of new initiatives, including recent hospital initiatives to limit the sale of sweetened beverages and other high calorie drinks in hospital vending machines and cafeterias. These proposed policy changes are not unique to United States, but are more comprehensive in the number of proposed hospitals that they will impact. Meanwhile, however, it is advised, that these i...

  8. Graphics-processing-unit-accelerated finite-difference time-domain simulation of the interaction between ultrashort laser pulses and metal nanoparticles

    Science.gov (United States)

    Nikolskiy, V. P.; Stegailov, V. V.

    2018-01-01

    Metal nanoparticles (NPs) serve as important tools for many modern technologies. However, the proper microscopic models of the interaction between ultrashort laser pulses and metal NPs are currently not very well developed in many cases. One part of the problem is the description of the warm dense matter that is formed in NPs after intense irradiation. Another part of the problem is the description of the electromagnetic waves around NPs. Description of wave propagation requires the solution of Maxwell’s equations and the finite-difference time-domain (FDTD) method is the classic approach for solving them. There are many commercial and free implementations of FDTD, including the open source software that supports graphics processing unit (GPU) acceleration. In this report we present the results on the FDTD calculations for different cases of the interaction between ultrashort laser pulses and metal nanoparticles. Following our previous results, we analyze the efficiency of the GPU acceleration of the FDTD algorithm.

  9. Modeling and analysis for determining optimal suppliers under stochastic lead times

    DEFF Research Database (Denmark)

    Abginehchi, Soheil; Farahani, Reza Zanjirani

    2010-01-01

    systems. The item acquisition lead times of suppliers are random variables. Backorder is allowed and shortage cost is charged based on not only per unit in shortage but also per time unit. Continuous review (s,Q) policy has been assumed. When the inventory level depletes to a reorder level, the total...... order is split among n suppliers. Since the suppliers have different characteristics, the quantity ordered to different suppliers may be different. The problem is to determine the reorder level and quantity ordered to each supplier so that the expected total cost per time unit, including ordering cost...

  10. A National Audit of Smoking Cessation Services in Irish Maternity Units

    LENUS (Irish Health Repository)

    2017-06-01

    There is international consensus that smoking cessation in the first half of pregnancy improves foetal outcomes. We surveyed all 19 maternity units nationally about their antenatal smoking cessation practices. All units recorded details on maternal smoking at the first antenatal visit. Only one unit validated the self-reported smoking status of pregnant women using a carbon monoxide breath test. Twelve units (63%) recorded timing of smoking cessation. In all units women who reported smoking were given verbal cessation advice. This was supported by written advice in 12 units (63%), but only six units (32%) had all midwives trained to provide this advice. Only five units (26%) reported routinely revisiting smoking status later in pregnancy. Although smoking is an important modifiable risk factor for adverse pregnancy outcomes, smoking cessation services are inadequate in the Irish maternity services and there are variations in practices between hospitals.

  11. Evaluation of datum unit for diagnostics of journal-bearing systems

    International Nuclear Information System (INIS)

    Jeon, Byung Chul; Jung, Joon Ha; Youn, Byeng Doog; Kim, Yeon Whan; Bae, Yong Chae

    2015-01-01

    Journal bearings support rotors using fluid film between the rotor and the stator. Generally, journal bearings are used in large rotor systems such as turbines in a power plant, because even in high-speed and load conditions, journal bearing systems run in a stable condition. To enhance the reliability of journal-bearing systems, in this paper, we study health-diagnosis algorithms that are based on the supervised learning method. Specifically, this paper focused on defining the unit of features, while other previous papers have focused on defining various features of vibration signals. We evaluate the features of various lengths or units on the separable ability basis. From our results, we find that one cycle datum in the time-domain and 60 cycle datum in the frequency domain are the optimal datum units for real-time journal-bearing diagnosis systems

  12. Evaluation of datum unit for diagnostics of journal-bearing systems

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Byung Chul; Jung, Joon Ha; Youn, Byeng Doog [Dept. of Mechanical and Aerospace Engineering, Seoul National University, Seoul (Korea, Republic of); Kim, Yeon Whan; Bae, Yong Chae [Power Generation Laboratory, KEPCO Research Institute, Daejeon (Korea, Republic of)

    2015-08-15

    Journal bearings support rotors using fluid film between the rotor and the stator. Generally, journal bearings are used in large rotor systems such as turbines in a power plant, because even in high-speed and load conditions, journal bearing systems run in a stable condition. To enhance the reliability of journal-bearing systems, in this paper, we study health-diagnosis algorithms that are based on the supervised learning method. Specifically, this paper focused on defining the unit of features, while other previous papers have focused on defining various features of vibration signals. We evaluate the features of various lengths or units on the separable ability basis. From our results, we find that one cycle datum in the time-domain and 60 cycle datum in the frequency domain are the optimal datum units for real-time journal-bearing diagnosis systems.

  13. Control system design specification of advanced spent fuel management process units

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S. H.; Kim, S. H.; Yoon, J. S

    2003-06-01

    In this study, the design specifications of instrumentation and control system for advanced spent fuel management process units are presented. The advanced spent fuel management process consists of several process units such as slitting device, dry pulverizing/mixing device, metallizer, etc. In this study, the control and operation characteristics of the advanced spent fuel management mockup process devices and the process devices developed in 2001 and 2002 are analysed. Also, a integral processing system of the unit process control signals is proposed, which the operation efficiency is improved. And a redundant PLC control system is constructed which the reliability is improved. A control scheme is proposed for the time delayed systems compensating the control performance degradation caused by time delay. The control system design specification is presented for the advanced spent fuel management process units. This design specifications can be effectively used for the detail design of the advanced spent fuel management process.

  14. Primary water chemistry control at units of Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Schunk, J.; Patek, G.; Pinter, T.; Tilky, P.; Doma, A.; Osz, J.

    2010-01-01

    The primary water chemistry of the four identical units of Paks Nuclear Power Plant has been developed based on Western-type PWR units, taking into consideration some Soviet-Russian modifications. The political changes in 90s have also influenced the water chemistry specifications and directions. At PWR units the transition operational modes have been developed while in case of VVER units - in lack of central uniform regulation - this question has become the competence and responsibility of each individual plant. This problem has resulted in separate water chemistry developments with a considerable time delay. The needs for life-time extensions all over the World have made the development of start-up and shut-down chemistry procedures extremely important, since they considerably influence the long term and safe operation of plants. The uniformly structured limit value system, the principles applied for the system development, and the logic schemes for actions to be taken are discussed in the paper, both for normal operation and transition modes. (author)

  15. Modifiable variables in physical therapy education programs associated with first-time and three-year National Physical Therapy Examination pass rates in the United States

    Directory of Open Access Journals (Sweden)

    Chad Cook

    2015-09-01

    Full Text Available Purpose: This study aimed to examine the modifiable programmatic characteristics reflected in the Commission on Accreditation in Physical Therapy Education (CAPTE Annual Accreditation Report for all accredited programs that reported pass rates on the National Physical Therapist Examination, and to build a predictive model for first-time and three-year ultimate pass rates. Methods: This observational study analyzed programmatic information from the 185 CAPTE-accredited physical therapy programs in the United States and Puerto Rico out of a total of 193 programs that provided the first-time and three-year ultimate pass rates in 2011. Fourteen predictive variables representing student selection and composition, clinical education length and design, and general program length and design were analyzed against first-time pass rates and ultimate pass rates on the NPTE. Univariate and multivariate multinomial regression analysis for first-time pass rates and logistic regression analysis for three-year ultimate pass rates were performed. Results: The variables associated with the first-time pass rate in the multivariate analysis were the mean undergraduate grade point average (GPA and the average age of the cohort. Multivariate analysis showed that mean undergraduate GPA was associated with the three-year ultimate pass rate. Conclusions: Mean undergraduate GPA was found to be the only modifiable predictor for both first-time and three-year pass rates among CAPTE-accredited physical therapy programs.

  16. Real time material accountability in a chemical reprocessing unit

    International Nuclear Information System (INIS)

    Morrison, G.W.; Blakeman, E.D.

    1979-01-01

    Real time material accountability for a pulse column in a chemical reprocessing plant has been investigated using a simple two state Kalman Filter. Operation of the pulse column was simulated by the SEPHIS-MOD4 code. Noisy measurements of the column inventory were obtained from two neutron detectors with various simulated counting errors. Various loss scenarios were simulated and analyzed by the Kalman Filter. In all cases considered the Kalman Filter was a superior estimator of material loss

  17. High precision timing in a FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Hoek, Matthias; Cardinali, Matteo; Dickescheid, Michael; Schlimme, Soeren; Sfienti, Concettina; Spruck, Bjoern; Thiel, Michaela [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet Mainz (Germany)

    2016-07-01

    A segmented highly precise start counter (FLASH) was designed and constructed at the Institute for Nuclear Physics in Mainz. Besides determining a precise reference time, a Time-of-Flight measurement can be performed with two identical FLASH units. Thus, particle identification can be provided for mixed hadron beam environments. The detector design is based on the detection of Cherenkov light produced in fused silica radiator bars with fast multi-anode MCP-PMTs. The segmentation of the radiator improves the timing resolution while allowing a coarse position resolution along one direction. Both, the arrival time and the Time-over-Threshold are determined by the readout electronics, which enables walk correction of the arrival time. The performance of two FLASH units was investigated in test experiments at the Mainz Microton (MAMI) using an electron beam with an energy of 855 MeV and at CERN's PS T9 beam line with a mixed hadron beam with momenta between 3-8 GeV/c. Effective Time-walk correction methods based on Time-over-Threshold were developed for the data analysis. The achieved Time-Of-Flight resolution after applying all corrections was found to be 70 ps. Furthermore, the PID and position resolution capabilities are discussed in this contribution.

  18. Jamestown and Disneyland: Two Places in Time.

    Science.gov (United States)

    Scrofani, E. Robert; Tideman, Robert

    This unit for high school students uses two dissimilar places in time; (2) Jamestown, Virginia, founded in 1607, one of the earliest settlements in the United States and (2) Disneyland, California, built in 1956, an institution of contemporary culture. The lessons address two fundamental questions in geography: (1) where? and (2) why here rather…

  19. Working on the Weekend: Fathers' Time with Family in the United Kingdom

    Science.gov (United States)

    Hook, Jennifer L.

    2012-01-01

    Whereas most resident fathers are able to spend more time with their children on weekends than on weekdays, many fathers work on the weekends, spending less time with their children on these days. There are conflicting findings about whether fathers are able to make up for lost weekend time on weekdays. Using unique features of the United…

  20. Mechanism of remote controlled after-loading radiotherapy unit

    International Nuclear Information System (INIS)

    Morimoto, Masaki

    1980-01-01

    Employing a small amount of Radium-226 or Cesium-137 source was to be used hitherto for the treatment of carcinoma of the uterine cervix in used After-loading techniques. It involved, however, radiation risk to the staff and patient. The long treatment time are also a pain (strain) on the patient. In recent years, we have developed a remote control after-loading unit, which was named as RALSTRON, which was complete eliminated the disadvantage of conventional radium therapy. This unit also has disadvantage, however, that the design for the remote after-loader for intracavitary applicators present considerable difficulties, because many sources of different active lengths and loading patterns are required. A solution to this problem was carried out by using small point source, placed in Tandem applicator, of high activity and moving them back slowly during the treatment. Recently, this unit was installed many hospitals about 80 units in Japan, and are used. In this paper are given about a mechanism and safety deviced of this unit. (author)

  1. Typhoid fever acquired in the United States, 1999-2010: epidemiology, microbiology, and use of a space-time scan statistic for outbreak detection.

    Science.gov (United States)

    Imanishi, M; Newton, A E; Vieira, A R; Gonzalez-Aviles, G; Kendall Scott, M E; Manikonda, K; Maxwell, T N; Halpin, J L; Freeman, M M; Medalla, F; Ayers, T L; Derado, G; Mahon, B E; Mintz, E D

    2015-08-01

    Although rare, typhoid fever cases acquired in the United States continue to be reported. Detection and investigation of outbreaks in these domestically acquired cases offer opportunities to identify chronic carriers. We searched surveillance and laboratory databases for domestically acquired typhoid fever cases, used a space-time scan statistic to identify clusters, and classified clusters as outbreaks or non-outbreaks. From 1999 to 2010, domestically acquired cases accounted for 18% of 3373 reported typhoid fever cases; their isolates were less often multidrug-resistant (2% vs. 15%) compared to isolates from travel-associated cases. We identified 28 outbreaks and two possible outbreaks within 45 space-time clusters of ⩾2 domestically acquired cases, including three outbreaks involving ⩾2 molecular subtypes. The approach detected seven of the ten outbreaks published in the literature or reported to CDC. Although this approach did not definitively identify any previously unrecognized outbreaks, it showed the potential to detect outbreaks of typhoid fever that may escape detection by routine analysis of surveillance data. Sixteen outbreaks had been linked to a carrier. Every case of typhoid fever acquired in a non-endemic country warrants thorough investigation. Space-time scan statistics, together with shoe-leather epidemiology and molecular subtyping, may improve outbreak detection.

  2. Tuberculosis along the United States-Mexico border, 1993-2001.

    Science.gov (United States)

    Schneider, Eileen; Laserson, Kayla F; Wells, Charles D; Moore, Marisa

    2004-07-01

    Tuberculosis (TB) is a leading public health problem and a recognized priority for the federal Governments of both Mexico and the United States of America. The objectives of this research, primarily for the four states in the United States that are along the border with Mexico, were to: (1) describe the epidemiological situation of TB, (2) identify TB risk factors, and (3) discuss tuberculosis program strategies. We analyzed tuberculosis case reports collected from 1993 through 2001 by the tuberculosis surveillance system of the United States. We used those data to compare TB cases mainly among three groups: (1) Mexican-born persons in the four United States border states (Arizona, California, New Mexico, and Texas), (2) persons in those four border states who had been born in the United States, and (3) Mexican-born persons in the 46 other states of the United States, which do not border Mexico. For the period from 1993 through 2001, of the 16 223 TB cases reported for Mexican-born persons in the United States, 12 450 of them (76.7%) were reported by Arizona, California, New Mexico, and Texas. In those four border states overall in 2001, tuberculosis case rates for Mexican-born persons were 5.0 times as high as the rates for persons born in the United States; those four states have 23 counties that directly border on Mexico, and the ratio in those counties was 5.8. HIV seropositivity, drug and alcohol use, unemployment, and incarceration were significantly less likely to be reported in Mexican-born TB patients from the four border states and the nonborder states than in patients born in the United States from the four border states (P pulmonary tuberculosis patients who were 18-64 years of age and residing in the four border states, the Mexican-born patients were 3.6 times as likely as the United States-born patients were to have resistance to at least isoniazid and rifampin (i. e., to have multidrug-resistant TB) and twice as likely to have isoniazid resistance

  3. Graphics processing unit (GPU) real-time infrared scene generation

    Science.gov (United States)

    Christie, Chad L.; Gouthas, Efthimios (Themie); Williams, Owen M.

    2007-04-01

    VIRSuite, the GPU-based suite of software tools developed at DSTO for real-time infrared scene generation, is described. The tools include the painting of scene objects with radiometrically-associated colours, translucent object generation, polar plot validation and versatile scene generation. Special features include radiometric scaling within the GPU and the presence of zoom anti-aliasing at the core of VIRSuite. Extension of the zoom anti-aliasing construct to cover target embedding and the treatment of translucent objects is described.

  4. Real-time Geomagnetic Data from a Raspberry Pi Magnetometer Network in the United Kingdom

    Science.gov (United States)

    Case, N.; Beggan, C.; Marple, S. R.

    2017-12-01

    In 2014, BGS and the University of Lancaster won an STFC Public Engagement grant to build and deploy 10 Raspberry Pi magnetometers to secondary schools across the UK to enable citizen science. The system uses a Raspberry Pi computer as a logging and data transfer device, connected to a set of three orthogonal miniature fluxgate magnetometers. The system has a nominal sensitivity of around 1 nanoTesla (nT), in each component direction (North, East and Down). This is around twenty times less sensitive than a current scientific-level instrument, but given its relatively low-cost, at about £250 ($325) per unit, this is an excellent price-to-performance ratio given we could not improve the sensitivity unless we spent a lot more money. The magnetic data are sampled at a 5 second cadence and sent to the AuroraWatch website at Lancaster University every 2 minutes. The data are freely available to view and download. The primary aim of the project is to encourage students from 14-18 years old to look at how sensors can be used to collect geophysical data and integrate it together to give a wider understanding of physical phenomena. A second aim is to provide useful data on the spatial variation of the magnetic field for analysis of geomagnetic storms, alongside data from the BGS observatory and University of Lancaster's SAMNET variometer network. We show results from the build, testing and running of the sensors including some recent storms and we reflect on our experiences in engaging schools and the general public with information about the magnetic field. The information to build the system and logging and analysis software for the Raspberry Pi is all freely available, allowing those interested to participate in the project as citizen scientists.

  5. A FPGA-based signal processing unit for a GEM array detector

    International Nuclear Information System (INIS)

    Yen, W.W.; Chou, H.P.

    2013-06-01

    in the present study, a signal processing unit for a GEM one-dimensional array detector is presented to measure the trajectory of photoelectrons produced by cosmic X-rays. The present GEM array detector system has 16 signal channels. The front-end unit provides timing signals from trigger units and energy signals from charge sensitive amplifies. The prototype of the processing unit is implemented using commercial field programmable gate array circuit boards. The FPGA based system is linked to a personal computer for testing and data analysis. Tests using simulated signals indicated that the FPGA-based signal processing unit has a good linearity and is flexible for parameter adjustment for various experimental conditions (authors)

  6. Consistent adoption of the International System of Units (SI) in nuclear science and technology

    Energy Technology Data Exchange (ETDEWEB)

    Klumpar, J; Kovar, Z [Ceskoslovenska Akademie Ved, Prague. Laborator Radiologicke Dozimetrie; Sacha, J [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Fyzikalny Ustav

    1975-11-01

    The principles are stressed behind a consistent introduction of the International System of Units (SI) in Czechoslovakia complying with the latest edition of the Czechoslovak Standard CSN 01 1300 on the prescribed system of national and international units. The use of special and auxiliary units in nuclear physics and technology is discussed, particular attention being devoted to the units of activity and to the time units applied in radiology. Conversion graph and tables are annexed.

  7. Quick setup of test unit for accelerator control system

    International Nuclear Information System (INIS)

    Fu, W.; D'Ottavio, T.; Gassner, D.; Nemesure, S.; Morris, J.

    2011-01-01

    Testing a single hardware unit of an accelerator control system often requires the setup of a program with graphical user interface. Developing a dedicated application for a specific hardware unit test could be time consuming and the application may become obsolete after the unit tests. This paper documents a methodology for quick design and setup of an interface focused on performing unit tests of accelerator equipment with minimum programming work. The method has three components. The first is a generic accelerator device object (ADO) manager which can be used to setup, store, and log testing controls parameters for any unit testing system. The second involves the design of a TAPE (Tool for Automated Procedure Execution) sequence file that specifies and implements all te testing and control logic. The sting third is the design of a PET (parameter editing tool) page that provides the unit tester with all the necessary control parameters required for testing. This approach has been used for testing the horizontal plane of the Stochastic Cooling Motion Control System at RHIC.

  8. About choosing the power unit of NPP

    International Nuclear Information System (INIS)

    Alekseev, P.N.; Mordashev, V.M.; Proshkin, A.A.; Stukalov, V.A.; Subbotin, S.A.; Tsibul'skij, V.F.; Chernilin, Yu.F.

    2008-01-01

    The present-day domestic nuclear power industry faces the necessity to make both process and economy related decisions. The mentioned decisions should cover all the aspects of the nuclear power complex. In particular, as of now, no substantiation of the present-day and the future requirements for the power unit of the WWER and fast reactor NPPs is available. The choice of the unit power of an NPP should involve consideration of all factors and should not be boiled down to the efforts to ensure the minimization of the investment and the operation constituents of the electric power generation costs. The aim of the present paper was to ensure elaboration of the recommendations to substantiate the optimal unit power of NPP power units based on the analysis of various factors to design, to construct and to operate an NPP (investment, time of construction, the unscheduled shutdown losses, the unification, the fabrication quality, the accident damage, etc.), and the electrical network potentialities and the regional electric power demands [ru

  9. Distributional curvature of time-dependent cosmic strings

    OpenAIRE

    Wilson, J P

    1997-01-01

    Colombeau's theory of generalised functions is used to calculate the contributions, at the rotation axis, to the distributional curvature for a time-dependent radiating cosmic string, and hence the mass per unit length of the string source. This mass per unit length is compared with the mass at null infinity, giving evidence for a global energy conservation law.

  10. The increase performance BMF-14 calcination unit

    International Nuclear Information System (INIS)

    Triyono

    2013-01-01

    The heating element of performance increase BMF-14 calcination unit has been installed. The activity includes: installation and function test heating element step by step. The main component includes: kanthal heating element type with size long 58,2 cm diameter 0,9 cm slot total 28, flexible cable resists heat 30 Amperes, band cable heat resists and flexible clamp. The heating elements installation includes from 3 groups and every groups have 4 heating elements to connectly series. Every group connecting to every phase RST and neutral for getting electric voltage 380 Volts follow contact relay 3 phases to controlling by digital temperature control. The resulting installation of heating element in the BMF-14 calcination unit showed that: BMF-14 calcination unit can be again of the setting temperature step by step. In the step I get optimal temperature 560 °C test time 1068 minutes with rate velocity heat 0 to 18,0 °C/minutes with current between 5,8 to 6,4 Amperes voltage 103 to 123 Volts (phase R and T). In the step II gets optimal temperature 600 °C test time 265 minutes getting rate velocity heat 0 to 40,3 °C/minutes with current 3,8 to 8,5 Amperes voltage 76 to 142 Volts (phase RST). In the step III gets optimal temperature 1000 °C test time 107 minutes getting rate velocity heat 0 to 53,5 °C/minutes with current 9,7 to 12,5 Amperes voltage 215 to 225 Volts (phase RST). (author)

  11. Four years Re-Use of low burned fuel assemblies from units 1 and 2 in core loadings of units 3 and 4 WWER-440 at Kozloduy NPP

    International Nuclear Information System (INIS)

    Stoyanova, I.; Antov, A.; Spasova, V.

    2006-01-01

    At the end of 2002 units 1 and 2 of Kozloduy NPP were shutdown before their design life time which left a large number of assemblies yet with a significant energy resources. A decision to load these assemblies into the cores of Units 3 and 4 during the next 4 cycles has been taken. In 2003, 43 assemblies from Unit 1 cycle 23 rd and 55 assemblies from Unit 2 cycle 24 th are loaded in the cores of units 3 and 4 respectively. In 2004, new 49 assemblies from Unit 1 cycle 23rd and new 55 assemblies from Unit 2 cycle 24th are loaded in the cores of units 3 and 4 respectively. In 2005, the next new 25 assemblies from Unit 1 cycle 23 rd and 66 assemblies from Unit 2 cycle 24th are loaded in the cores of units 3 and 4 respectively. In 2006, the next new 54 assemblies from Unit 1 cycle 23 rd and 52 assemblies from Unit 2 cycle 24 th + 2 assemblies from Unit 3 cycle 19th are loaded in the cores of Units 3 and 4 respectively. The SPPSHB computer code system is used for development and safety assessment of the fuel loading patterns of Units 3 and 4 at Kozloduy NPP with low burned assemblies from units 1 and 2 (Authors)

  12. The effects of the framing of time on delay discounting.

    Science.gov (United States)

    DeHart, William Brady; Odum, Amy L

    2015-01-01

    We examined the effects of the framing of time on delay discounting. Delay discounting is the process by which delayed outcomes are devalued as a function of time. Time in a titrating delay discounting task is often framed in calendar units (e.g., as 1 week, 1 month, etc.). When time is framed as a specific date, delayed outcomes are discounted less compared to the calendar format. Other forms of framing time; however, have not been explored. All participants completed a titrating calendar unit delay-discounting task for money. Participants were also assigned to one of two delay discounting tasks: time as dates (e.g., June 1st, 2015) or time in units of days (e.g., 5000 days), using the same delay distribution as the calendar delay-discounting task. Time framed as dates resulted in less discounting compared to the calendar method, whereas time framed as days resulted in greater discounting compared to the calendar method. The hyperboloid model fit best compared to the hyperbola and exponential models. How time is framed may alter how participants attend to the delays as well as how the delayed outcome is valued. Altering how time is framed may serve to improve adherence to goals with delayed outcomes. © Society for the Experimental Analysis of Behavior.

  13. Comparative Evaluation of Shear Bond Strength and Debonding Characteristics using Conventional Halogen Light Curing Unit and LED Light Curing Unit: An in vitro Study

    Directory of Open Access Journals (Sweden)

    Amit Bhardwaj

    2013-01-01

    Conclusion: The result of this study showed promise for the orthodontic application of LED as light curing units and 20 seconds of exposure time is adequate for both LED and Halogen light, since increasing the curing time to 40 seconds showed no significant difference.

  14. Photographs of the Sea floor Offshore of New York and New Jersey

    Science.gov (United States)

    Butman, Bradford; Gutierrez, Benjamin T.; Buchholtz ten Brink, Marilyn R.; Schwab, William S.; Blackwood, Dann S.; Mecray, Ellen L.; Middleton, Tammie J.

    2003-01-01

    This DVD-ROM contains photographs of the sea floor and sediment texture data collected as part of studies carried out by the U.S. Geological Survey (USGS) in the New York Bight (Figure 1a (PDF format)). The studies were designed to map the sea floor (Butman, 1998, URL: http://pubs.usgs.gov/fs/fs133-98/) and to develop an understanding of the transport and long-term fate of sediments and associated contaminants in the region (Mecray and others, 1999, URL: http://pubs.usgs.gov/fs/fs114-99/). The data were collected on four research cruises carried out between 1996 and 2000 (Appendix I). The images and texture data were collected to provide direct observations of the sea floor geology and to aid in the interpretation of backscatter intensity data obtained from sidescan sonar and multibeam surveys of the sea floor. Preliminary descriptions of the sea floor geology in this region may be found in Schwab and others (2000, URL: http://pubs.usgs.gov/of/of00-295/; 2003), Butman and others (1998, URL: http://pubs.usgs.gov/of/of98-616/.), and Butman and others (2002, URL: http://pubs.usgs.gov/of/of00-503/). Schwab and others (2000 URL: http://pubs.usgs.gov/of/of00-295/; 2003) have identified 11 geologic units in New York Bight (Figure 2 (PDF format)). These units identify areas of active sediment transport, extensive anthropogenic influence on the sea floor, and various geologic units. Butman and others (2003) and Harris and others (in press) present the results of a moored array experiment carried out in the Hudson Shelf Valley to investigate the transport of sediments during winter. Summaries of these and other studies may be found at USGS studies in the New York Bight (URL: http://woodshole.er.usgs.gov/project-pages/newyork/). This DVD-ROM contains digital images of bottom still photographs, images digitized from videos, sediment grain-size analysis results, and short QuickTime movies from video transects. The data are presented in tabular form and in an ESRI (Environmental

  15. Timing of low tidal volume ventilation and intensive care unit mortality in acute respiratory distress syndrome. A prospective cohort study.

    Science.gov (United States)

    Needham, Dale M; Yang, Ting; Dinglas, Victor D; Mendez-Tellez, Pedro A; Shanholtz, Carl; Sevransky, Jonathan E; Brower, Roy G; Pronovost, Peter J; Colantuoni, Elizabeth

    2015-01-15

    Reducing tidal volume decreases mortality in acute respiratory distress syndrome (ARDS). However, the effect of the timing of low tidal volume ventilation is not well understood. To evaluate the association of intensive care unit (ICU) mortality with initial tidal volume and with tidal volume change over time. Multivariable, time-varying Cox regression analysis of a multisite, prospective study of 482 patients with ARDS with 11,558 twice-daily tidal volume assessments (evaluated in milliliter per kilogram of predicted body weight [PBW]) and daily assessment of other mortality predictors. An increase of 1 ml/kg PBW in initial tidal volume was associated with a 23% increase in ICU mortality risk (adjusted hazard ratio, 1.23; 95% confidence interval [CI], 1.06-1.44; P = 0.008). Moreover, a 1 ml/kg PBW increase in subsequent tidal volumes compared with the initial tidal volume was associated with a 15% increase in mortality risk (adjusted hazard ratio, 1.15; 95% CI, 1.02-1.29; P = 0.019). Compared with a prototypical patient receiving 8 days with a tidal volume of 6 ml/kg PBW, the absolute increase in ICU mortality (95% CI) of receiving 10 and 8 ml/kg PBW, respectively, across all 8 days was 7.2% (3.0-13.0%) and 2.7% (1.2-4.6%). In scenarios with variation in tidal volume over the 8-day period, mortality was higher when a larger volume was used earlier. Higher tidal volumes shortly after ARDS onset were associated with a greater risk of ICU mortality compared with subsequent tidal volumes. Timely recognition of ARDS and adherence to low tidal volume ventilation is important for reducing mortality. Clinical trial registered with www.clinicaltrials.gov (NCT 00300248).

  16. 40 CFR 60.1810 - How do I monitor the load of my municipal waste combustion unit?

    Science.gov (United States)

    2010-07-01

    ... municipal waste combustion unit? 60.1810 Section 60.1810 Protection of Environment ENVIRONMENTAL PROTECTION... Guidelines and Compliance Times for Small Municipal Waste Combustion Units Constructed on or Before August 30... combustion unit? (a) If your municipal waste combustion unit generates steam, you must install, calibrate...

  17. Antenna unit and radio base station therewith

    Science.gov (United States)

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  18. Experience gained in the cryodistillation unit for krypton removal

    International Nuclear Information System (INIS)

    Geens, L.; Collard, G.; Goossens, W.R.A.; Vaesen, P.J.

    1981-08-01

    This unit with a nominal gas throughput of 8.5 g.s -1 has been used to investigate the removal of krypton from reprocessing off-gases under non-radioactive conditions. During the investigation a total operation time of more than 13.000 hours was reached with an average availability factor of 99.36%. The trapping efficiency for krypton was higher than 99.9%. The operation experience acquired indicates some critical aspects for the design of such a unit. The experimental results obtained allow to show the influence of feed pressure and temperature, reflux flow rate and noble gas concentrations on the performance of the unit. (author)

  19. Laundry, energy and time: Insights from 20 years of time-use diary data in the United Kingdom

    OpenAIRE

    Anderson, Ben

    2016-01-01

    The uneven temporal distribution of domestic energy demand is a well-known phenomenon that is increasingly troublesome for energy infrastructures and sustainable or low carbon energy systems. People tend to demand energy, and especially electricity, at specific times of the day and they do not necessarily do so when the sun is shining or the wind is blowing. The potential value of demand response as a solution rests on understanding the nature of temporal energy demand and the timing of the i...

  20. Simulation of motor unit recruitment and microvascular unit perfusion: spatial considerations.

    Science.gov (United States)

    Fuglevand, A J; Segal, S S

    1997-10-01

    Muscle fiber activity is the principal stimulus for increasing capillary perfusion during exercise. The control elements of perfusion, i.e., microvascular units (MVUs), supply clusters of muscle fibers, whereas the control elements of contraction, i.e., motor units, are composed of fibers widely scattered throughout muscle. The purpose of this study was to examine how the discordant spatial domains of MVUs and motor units could influence the proportion of open capillaries (designated as perfusion) throughout a muscle cross section. A computer model simulated the locations of perfused MVUs in response to the activation of up to 100 motor units in a muscle with 40,000 fibers and a cross-sectional area of 100 mm2. The simulation increased contraction intensity by progressive recruitment of motor units. For each step of motor unit recruitment, the percentage of active fibers and the number of perfused MVUs were determined for several conditions: 1) motor unit fibers widely dispersed and motor unit territories randomly located (which approximates healthy human muscle), 2) regionalized motor unit territories, 3) reversed recruitment order of motor units, 4) densely clustered motor unit fibers, and 5) increased size but decreased number of motor units. The simulations indicated that the widespread dispersion of motor unit fibers facilitates complete capillary (MVU) perfusion of muscle at low levels of activity. The efficacy by which muscle fiber activity induced perfusion was reduced 7- to 14-fold under conditions that decreased the dispersion of active fibers, increased the size of motor units, or reversed the sequence of motor unit recruitment. Such conditions are similar to those that arise in neuromuscular disorders, with aging, or during electrical stimulation of muscle, respectively.

  1. LIDAR COMBINED SCANNING UNIT

    Directory of Open Access Journals (Sweden)

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  2. Cigarette Smoking among Korean International College Students in the United States

    Science.gov (United States)

    Sa, Jaesin; Seo, Dong-Chul; Nelson, Toben F.; Lohrmann, David K.

    2013-01-01

    Objective and Participants: This study explored (1) the prevalence of cigarette smoking among South Korean international college students in the United States, (2) differences in smoking between on- and off-campus living arrangements, and (3) predictors of an increase in smoking over time in the United States Methods: An online survey was…

  3. Part-time working in Ireland in a European context

    OpenAIRE

    DREW, EILEEN PATRICIA

    1991-01-01

    Read before the Society, 25 October 1990 The subject of part-time work is one which has become increasingly important in industrialized economies, most notably Norway, Sweden, United States, Canada, Denmark and the United Kingdom, where it accounts for a substantial and growing proportion of total employment. It has been noted that resort to part-time workers was generally a response to a shortage of available labour, particularly when it coincided with periods of economic ...

  4. Construction: first of St. Lucie unit 2 successes

    International Nuclear Information System (INIS)

    Conway, W.F.

    1989-01-01

    The Nuclear Regulatory Commission (NRC) granted a full power operating license for St. Lucie Unit 2 on June 10, 1983, just six years after construction began. The industry average for nuclear power plant construction during this time was approximately ten years. The rate of completion had a positive effect on the cost of the facility. The price of the unit was $1.42 billion as compared to the $2 billion to $5 billion range experienced by other utilities for nuclear plants. These accomplishments were not serendipitous but the results of management techniques and personnel attitudes involved in the construction of the unit. More importantly, many of these same techniques and attitudes have now become part of a quality improvement program at St Lucie and are reflected in its performance indicators. This paper analyzes the construction success of St Lucie Unit 2 and demonstrates that excellent performance in the construction phase can be carried over to the operation of a facility

  5. Contemporary Fertility Patterns and First-Birth Timing among Mexican-Origin Women

    Science.gov (United States)

    Batson, Christie D.

    2013-01-01

    This article examines first-birth timing among Mexican women in the United States over two birth cohorts. Currently, Mexican women are one of a small group that maintains above-replacement fertility in the United States, contributing to both Mexican population growth and overall national population growth. Yet, the fertility timing of Mexican…

  6. United States rejoin ITER

    International Nuclear Information System (INIS)

    Roberts, M.

    2003-01-01

    Upon pressure from the United States Congress, the US Department of Energy had to withdraw from further American participation in the ITER Engineering Design Activities after the end of its commitment to the EDA in July 1998. In the years since that time, changes have taken place in both the ITER activity and the US fusion community's position on burning plasma physics. Reflecting the interest in the United States in pursuing burning plasma physics, the DOE's Office of Science commissioned three studies as part of its examination of the option of entering the Negotiations on the Agreement on the Establishment of the International Fusion Energy Organization for the Joint Implementation of the ITER Project. These were a National Academy Review Panel Report supporting the burning plasma mission; a Fusion Energy Sciences Advisory Committee (FESAC) report confirming the role of ITER in achieving fusion power production, and The Lehman Review of the ITER project costing and project management processes (for the latter one, see ITER CTA Newsletter, no. 15, December 2002). All three studies have endorsed the US return to the ITER activities. This historical decision was announced by DOE Secretary Abraham during his remarks to employees of the Department's Princeton Plasma Physics Laboratory. The United States will be working with the other Participants in the ITER Negotiations on the Agreement and is preparing to participate in the ITA

  7. CLIM : A cross-level workload-aware timing error prediction model for functional units

    NARCIS (Netherlands)

    Jiao, Xun; Rahimi, Abbas; Jiang, Yu; Wang, Jianguo; Fatemi, Hamed; De Gyvez, Jose Pineda; Gupta, Rajesh K.

    2018-01-01

    Timing errors that are caused by the timing violations of sensitized circuit paths, have emerged as an important threat to the reliability of synchronous digital circuits. To protect circuits from these timing errors, designers typically use a conservative timing margin, which leads to operational

  8. Part-Time Faculty in 2-Year Colleges.

    Science.gov (United States)

    National Center for the Study of Collective Bargaining in Higher Education Newsletter, 1977

    1977-01-01

    Recognition clauses of negotiated faculty contracts from 139 two-year colleges were analyzed to determine the extent to which part-time faculty are included in the bargaining unit, and to examine contract references to part-time faculty. Approximately one-half (71) of the contracts did not include part-time faculty as members. Exclusion was either…

  9. Mapping the Information Trace in Local Field Potentials by a Computational Method of Two-Dimensional Time-Shifting Synchronization Likelihood Based on Graphic Processing Unit Acceleration.

    Science.gov (United States)

    Zhao, Zi-Fang; Li, Xue-Zhu; Wan, You

    2017-12-01

    The local field potential (LFP) is a signal reflecting the electrical activity of neurons surrounding the electrode tip. Synchronization between LFP signals provides important details about how neural networks are organized. Synchronization between two distant brain regions is hard to detect using linear synchronization algorithms like correlation and coherence. Synchronization likelihood (SL) is a non-linear synchronization-detecting algorithm widely used in studies of neural signals from two distant brain areas. One drawback of non-linear algorithms is the heavy computational burden. In the present study, we proposed a graphic processing unit (GPU)-accelerated implementation of an SL algorithm with optional 2-dimensional time-shifting. We tested the algorithm with both artificial data and raw LFP data. The results showed that this method revealed detailed information from original data with the synchronization values of two temporal axes, delay time and onset time, and thus can be used to reconstruct the temporal structure of a neural network. Our results suggest that this GPU-accelerated method can be extended to other algorithms for processing time-series signals (like EEG and fMRI) using similar recording techniques.

  10. Norm-times : a design for production time and variability reduction for Faes Cases

    NARCIS (Netherlands)

    Karandeinos, Georgios

    2008-01-01

    This project deals with the production process of Faes Cases business unit. This company is producing custom-made packaging and sells standard solutions with customized interior. During the last years, it was observed that the throughput time of the production is increasing and is hard to forecast

  11. Multi-Unit Aspects of the Pickering Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Morison, W. G. [Atomic Energy of Canada Ltd, Sheridan Park, ON (Canada)

    1968-04-15

    The Pickering nuclear generating station is located on the north shore of Lake Ontario, about 20 miles east of the city of Toronto, Canada. The station has been planned and laid out on an eight-unit station, four units of which have now been authorized for construction. Each of these four units consists of a single heavy-water moderated and cooled CANDU-type reactor and auxiliaries coupled to a single tandem compound turbine generator with a net output of approximately 500 MW(e). The units are identical and are scheduled to come into operation at intervals of one year from 1970 to 1973. The station has been planned with central facilities for: administration maintenance laboratories, stores, change rooms, decontamination and waste management services. A common control centre, cooling water intake and discharge system, and spent fuel storage bay for four units has been arranged. A feature of the multi-unit station is a common containment system. Cost savings in building a number of identical units on the same site result from a single exclusion area, shared engineering costs, equipment purchase contracts for four identical components, and efficient use of construction plant. Operating cost savings are anticipated in the use of a common operating and maintenance staff and spare parts inventory. The plant has been arranged to minimize problems of operating, commissioning and constructing units at the same time on the same site. The layout and construction sequence have been arranged so that the first unit can be commissioned and operated with little or no interference from the construction forces working on succeeding units. During the construction phase barriers will be erected in the common control centre between operating control equipment and that being installed. Operations and construction personnel will enter the plant by separate routes and work in areas separated by physical barriers. (author)

  12. Multistage parallel-serial time averaging filters

    International Nuclear Information System (INIS)

    Theodosiou, G.E.

    1980-01-01

    Here, a new time averaging circuit design, the 'parallel filter' is presented, which can reduce the time jitter, introduced in time measurements using counters of large dimensions. This parallel filter could be considered as a single stage unit circuit which can be repeated an arbitrary number of times in series, thus providing a parallel-serial filter type as a result. The main advantages of such a filter over a serial one are much less electronic gate jitter and time delay for the same amount of total time uncertainty reduction. (orig.)

  13. Allocation of nursing care hours in a combined ophthalmic nursing unit.

    Science.gov (United States)

    Navarro, V B; Stout, W A; Tolley, F M

    1995-04-01

    Traditional service configuration with separate nursing units for outpatient and inpatient care is becoming ineffective for new patient care delivery models. With the new configuration of a combined nursing unit, it was necessary to rethink traditional reporting methodologies and calculation of hours of care. This project management plan is an initial attempt to develop a standard costing/productivity model for a combined unit. The methodology developed from this plan measures nursing care hours for each patient population to determine the number of full time equivalents (FTEs) for a combined unit and allocates FTEs based on inpatient (IP), outpatient (OP), and emergency room (ER) volumes.

  14. Penelitian penentuan konstanta saturasi (Ks pada rbc unit

    Directory of Open Access Journals (Sweden)

    Prayitno Prayitno

    1992-04-01

    Full Text Available Kinetic of Rotating Biological Contractor have been investigated by manu researchers. In general the model emploued either saturation kinetic (following Monod equation or first order kinetic to describe substrate removal. In this experiment, saturation kinetic model was used to find out the saturation constant of the RBC unit. The influent fed into the unit was synthetic waste water with glucose as organic carbon sources. The flow was maintained constant at 20.4 1/d and COD influent resulted the saturation constant (Ks 11.17 mg/I with 20 hours of detention time.

  15. Training for integrated digital I and C system of Tomari unit 3

    International Nuclear Information System (INIS)

    Tutiya, Akiyoshi; Sanbe, Takayuki; Hayashi, Hiroshi

    2009-01-01

    In Tomari nuclear power station Unit No.3, integrated digital I and C facilities was applied for each control unit including safety protection system overall and which connect them by bus (a network), and perform data communications for the first time as a Japanese PWR power station. For the continuation of safe and stable operation of Tomari nuclear power station Unit No.3 which is our greatest power supply, it is important to perform appropriate maintenance jobs about integrated digital I and C System at the time of normal operation, periodical inspection and trouble outbreak. For the assured accomplishment of these work by maintenance personnel, we clarified goal of necessary knowledge and skills and examined training facilities and curriculums. (author)

  16. 40 CFR 60.2991 - What incineration units must I address in my State plan?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What incineration units must I address... and Compliance Times for Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Applicability of State Plans § 60.2991 What incineration units must I address in my State...

  17. Taxation of United States general aviation

    Science.gov (United States)

    Sobieralski, Joseph Bernard

    General aviation in the United States has been an important part of the economy and American life. General aviation is defined as all flying excluding military and scheduled airline operations, and is utilized in many areas of our society. The majority of aircraft operations and airports in the United States are categorized as general aviation, and general aviation contributes more than one percent to the United States gross domestic product each year. Despite the many benefits of general aviation, the lead emissions from aviation gasoline consumption are of great concern. General aviation emits over half the lead emissions in the United States or over 630 tons in 2005. The other significant negative externality attributed to general aviation usage is aircraft accidents. General aviation accidents have caused over 8000 fatalities over the period 1994-2006. A recent Federal Aviation Administration proposed increase in the aviation gasoline tax from 19.4 to 70.1 cents per gallon has renewed interest in better understanding the implications of such a tax increase as well as the possible optimal rate of taxation. Few studies have examined aviation fuel elasticities and all have failed to study general aviation fuel elasticities. Chapter one fills that gap and examines the elasticity of aviation gasoline consumption in United States general aviation. Utilizing aggregate time series and dynamic panel data, the price and income elasticities of demand are estimated. The price elasticity of demand for aviation gasoline is estimated to range from -0.093 to -0.185 in the short-run and from -0.132 to -0.303 in the long-run. These results prove to be similar in magnitude to automobile gasoline elasticities and therefore tax policies could more closely mirror those of automobile tax policies. The second chapter examines the costs associated with general aviation accidents. Given the large number of general aviation operations as well as the large number of fatalities and

  18. The Simpsons in Leisure Time

    Directory of Open Access Journals (Sweden)

    Heshmat Sadat Moinifar

    2011-04-01

    Full Text Available Everyday life representation is the subject of many media productions in the United States. While talking about everyday life, family could be very significant factor. Many different television genres in US such as soap operas and sitcoms which their emergence dated back to 1950s, have specified their topics to representation of family relations, dilemmas and problems. Leisure time and consumption patterns in a consumer society could be important in a sense that family relation, the way of choosing those patterns and their representation, could clarify the form and types of family relations in United States. Generally, understanding a family could be taken as a small piece of the greater society. The subject of study in this article is The Simpsons situation comedy. This famous situation comedies’ reputation has surpassed many cultural borders dates back to 1980s. As this sitcom is about American everyday life has absorbed many American and non-American viewers. This article will study the seasons 3-8 of this sitcom to answer the two following questions: 1. How every member of the Simpsons family, personally spend their leisure time? 2. How the Simpsons family spend their leisure time collectively? The theoretical base of this article is Stuart Hall`s theory of representation and the method is semiology. The unit of analysis in related sections is sequence and scene and in non-related sections is the subject of the special section.

  19. Paracetamol overdose: the liver unit perspective.

    LENUS (Irish Health Repository)

    Iqbal, M

    2012-09-01

    Liver failure resulting from deliberate or accidental paracetamol overdose continues to be an important reason for referral to liver transplant centres. Severe hepatic dysfunction often appears 72-96 h after overdose. Liver injury can be prevented by timely administration of the specific antidote, N-acetylcysteine. Unfortunately, administration of N-acetylcysteine is frequently delayed due to late presentation or late administration. While N-acetylcysteine works best if given within 8 h of overdose, it is beneficial at any time period and should always be given if there is concern about significant overdose, irrespective of interval from time of ingestion. Early discussion with liver transplant unit is suggested if there is any doubt or evidence of liver failure.

  20. United States forest disturbance trends observed with landsat time series

    Science.gov (United States)

    Jeffrey G. Masek; Samuel N. Goward; Robert E. Kennedy; Warren B. Cohen; Gretchen G. Moisen; Karen Schleweiss; Chengquan. Huang

    2013-01-01

    Disturbance events strongly affect the composition, structure, and function of forest ecosystems; however, existing US land management inventories were not designed to monitor disturbance. To begin addressing this gap, the North American Forest Dynamics (NAFD) project has examined a geographic sample of 50 Landsat satellite image time series to assess trends in forest...

  1. Optical timing receiver for the NASA Spaceborne Ranging System. Part I. Dual peak-sensing timing discriminator

    International Nuclear Information System (INIS)

    Leskovar, B.; Lo, C.C.; Zizka, G.

    1978-01-01

    Position-resolution capabilities of the NASA Spaceborne Laser Ranging System are essentially determined by the time-resolution capabilities of its optical timing receiver. The optical timing receiver consists of a fast photoelectric device; (e.g., photomultiplier or an avalanche photodiode detector), a timing discriminator, a high-precision event-timing digitizer, and a signal-processing system. The time-resolution capabilities of the receiver are determined by the photoelectron time spread of the photoelectric device, the time walk and resolution characteristics of the timing discriminator, and the resolution of the event-timing digitizer. It is thus necessary to evaluate available fast photoelectronic devices with respect to their time-resolution capabilities, to design a very low time walk timing discriminator and to develop a high-resolution event-timing digitizer which will be used in the high-resolution spaceborne laser ranging system receiver. The development of a new dual-peak sensing timing discriminator is described. The amplitude dependent time walk is less than +-150 psec for a 100:1 dynamic range of Gaussian-shaped input signals having pulse widths between 11 and 17 nsec. The unit produces 800 mV negative output pulses, each 10 nsec wide, and 3V positive pulses with widths of 15 nsec. The time delay through the discriminator is approximately 37 nsec. In this discriminator the input signal is processed by a peak-crossing circuit which produces a bipolar pulse having its zero-crossing point at the peak of the input signal. All essential functions in the discriminator are performed by means of tunnel diodes with backward diodes as nonlinear loads. The discriminator is designed to be CAMAC compatible to a conventional time-interval unit or a high-precision event timing digitizer. The adjustment procedure for obtaining minimum time walk is also given

  2. Timing of nurses activities: human resources management

    Directory of Open Access Journals (Sweden)

    Hamid Hosein Poor

    2016-11-01

    Full Text Available Costs of human resources include a high percentage of hospital’s costs; therefore, determination of number of real and optimal employees needed for organizations is very important. In the meantime, the optimal organization of nurses, as the biggest human resource in health care organizations, is of great importance. The present study aimed to assess the distribution of nurses’ activities in shifts and the results of productivity in human resources management in Imam Khomeini hospital in Shirvan. The present cross-sectional study was conducted in 2016. All nurses, working in three shifts of morning, afternoon, and evening in emergency unit and general units of Imam Khomeini hospital, Shirvan, were enrolled into the study through census methods. The instrument, used in this study, was the checklist of timing activities and patients’ satisfaction from nurses. The statistical software SPSS was used for analysis. Mean age of employees in these two units/wards was 31 years and mean duration of work experience was 5.24 years, The difference was significant between the two wards. necessity of the work, especially in emergency unit, are issues that need more assessment and need to be adjusted. Given the high volume of non-care matters of nursing staff, including writing services, including completing paper records and work with HIS (Hospital Information System, which has been emphasized in several studies, new definition of service and use of artificial intelligence with high efficacy is proposed. The status of the available equipment, availability, and efficiency of digital equipment and hoteling state of wards and hospitals also play an important factor in the distribution of time of nursing care activities. Employment of nurses to perform non-nursing duties, because of the shortage of other classes or lack of their permanent presence and based on Although there were differences in standard time of direct and indirect care in emergency unit and

  3. 5 CFR 890.101 - Definitions; time computations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Definitions; time computations. 890.101....101 Definitions; time computations. (a) In this part, the terms annuitant, carrier, employee, employee... in section 8901 of title 5, United States Code, and supplement the following definitions: Appropriate...

  4. Identifying modules of coexpressed transcript units and their organization of Saccharopolyspora erythraea from time series gene expression profiles.

    Directory of Open Access Journals (Sweden)

    Xiao Chang

    Full Text Available BACKGROUND: The Saccharopolyspora erythraea genome sequence was released in 2007. In order to look at the gene regulations at whole transcriptome level, an expression microarray was specifically designed on the S. erythraea strain NRRL 2338 genome sequence. Based on these data, we set out to investigate the potential transcriptional regulatory networks and their organization. METHODOLOGY/PRINCIPAL FINDINGS: In view of the hierarchical structure of bacterial transcriptional regulation, we constructed a hierarchical coexpression network at whole transcriptome level. A total of 27 modules were identified from 1255 differentially expressed transcript units (TUs across time course, which were further classified in to four groups. Functional enrichment analysis indicated the biological significance of our hierarchical network. It was indicated that primary metabolism is activated in the first rapid growth phase (phase A, and secondary metabolism is induced when the growth is slowed down (phase B. Among the 27 modules, two are highly correlated to erythromycin production. One contains all genes in the erythromycin-biosynthetic (ery gene cluster and the other seems to be associated with erythromycin production by sharing common intermediate metabolites. Non-concomitant correlation between production and expression regulation was observed. Especially, by calculating the partial correlation coefficients and building the network based on Gaussian graphical model, intrinsic associations between modules were found, and the association between those two erythromycin production-correlated modules was included as expected. CONCLUSIONS: This work created a hierarchical model clustering transcriptome data into coordinated modules, and modules into groups across the time course, giving insight into the concerted transcriptional regulations especially the regulation corresponding to erythromycin production of S. erythraea. This strategy may be extendable to studies

  5. Identifying modules of coexpressed transcript units and their organization of Saccharopolyspora erythraea from time series gene expression profiles.

    Science.gov (United States)

    Chang, Xiao; Liu, Shuai; Yu, Yong-Tao; Li, Yi-Xue; Li, Yuan-Yuan

    2010-08-12

    The Saccharopolyspora erythraea genome sequence was released in 2007. In order to look at the gene regulations at whole transcriptome level, an expression microarray was specifically designed on the S. erythraea strain NRRL 2338 genome sequence. Based on these data, we set out to investigate the potential transcriptional regulatory networks and their organization. In view of the hierarchical structure of bacterial transcriptional regulation, we constructed a hierarchical coexpression network at whole transcriptome level. A total of 27 modules were identified from 1255 differentially expressed transcript units (TUs) across time course, which were further classified in to four groups. Functional enrichment analysis indicated the biological significance of our hierarchical network. It was indicated that primary metabolism is activated in the first rapid growth phase (phase A), and secondary metabolism is induced when the growth is slowed down (phase B). Among the 27 modules, two are highly correlated to erythromycin production. One contains all genes in the erythromycin-biosynthetic (ery) gene cluster and the other seems to be associated with erythromycin production by sharing common intermediate metabolites. Non-concomitant correlation between production and expression regulation was observed. Especially, by calculating the partial correlation coefficients and building the network based on Gaussian graphical model, intrinsic associations between modules were found, and the association between those two erythromycin production-correlated modules was included as expected. This work created a hierarchical model clustering transcriptome data into coordinated modules, and modules into groups across the time course, giving insight into the concerted transcriptional regulations especially the regulation corresponding to erythromycin production of S. erythraea. This strategy may be extendable to studies on other prokaryotic microorganisms.

  6. CONTRACTION CHARACTERISTICS AND MYOSIN HEAVY-CHAIN COMPOSITION OF RABBIT MASSETER MOTOR UNITS

    NARCIS (Netherlands)

    KWA, SHS; WEIJS, WA; JUCH, PJW

    1. We studied isometric twitch peak force (TPF) and twitch contraction time (TCT) of 249 motor units of the masseter muscle in 41 rabbits after extracellular electrical stimulation of single trigeminal motoneurons in the brain stem. In 41 of these units we determined the amount of tension decrease

  7. The economic implications of later school start times in the United States.

    Science.gov (United States)

    Hafner, Marco; Stepanek, Martin; Troxel, Wendy M

    2017-12-01

    Numerous studies have shown that later school start times (SST) are associated with positive student outcomes, including improvements in academic performance, mental and physical health, and public safety. While the benefits of later SST are very well documented in the literature, in practice there is opposition against delaying SST. A major argument against later SST is the claim that delaying SST will result in significant additional costs for schools due to changes in bussing strategies. However, to date, there has only been one published study that has quantified the potential economic benefits of later SST in relation to potential costs. The current study investigates the economic implications of later school start times by examining a policy experiment and its subsequent state-wide economic effects of a state-wide universal shift in school start times to 8.30AM. Using a novel macroeconomic modeling approach, the study estimates changes in the economic performance of 47 US states following a delayed school start time, which includes the benefits of higher academic performance of students and reduced car crash rates. The benefit-cost projections of this study suggest that delaying school start times is a cost-effective, population-level strategy, which could have a significant impact on public health and the US economy. From a policy perspective, these findings are crucial as they demonstrate that significant economic gains resulting from the delay in SST accrue over a relatively short period of time following the adoption of the policy shift. Copyright © 2017 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  8. Typhoid fever acquired in the United States, 1999–2010: epidemiology, microbiology, and use of a space–time scan statistic for outbreak detection

    Science.gov (United States)

    IMANISHI, M.; NEWTON, A. E.; VIEIRA, A. R.; GONZALEZ-AVILES, G.; KENDALL SCOTT, M. E.; MANIKONDA, K.; MAXWELL, T. N.; HALPIN, J. L.; FREEMAN, M. M.; MEDALLA, F.; AYERS, T. L.; DERADO, G.; MAHON, B. E.; MINTZ, E. D.

    2016-01-01

    SUMMARY Although rare, typhoid fever cases acquired in the United States continue to be reported. Detection and investigation of outbreaks in these domestically acquired cases offer opportunities to identify chronic carriers. We searched surveillance and laboratory databases for domestically acquired typhoid fever cases, used a space–time scan statistic to identify clusters, and classified clusters as outbreaks or non-outbreaks. From 1999 to 2010, domestically acquired cases accounted for 18% of 3373 reported typhoid fever cases; their isolates were less often multidrug-resistant (2% vs. 15%) compared to isolates from travel-associated cases. We identified 28 outbreaks and two possible outbreaks within 45 space–time clusters of ⩾2 domestically acquired cases, including three outbreaks involving ⩾2 molecular subtypes. The approach detected seven of the ten outbreaks published in the literature or reported to CDC. Although this approach did not definitively identify any previously unrecognized outbreaks, it showed the potential to detect outbreaks of typhoid fever that may escape detection by routine analysis of surveillance data. Sixteen outbreaks had been linked to a carrier. Every case of typhoid fever acquired in a non-endemic country warrants thorough investigation. Space–time scan statistics, together with shoe-leather epidemiology and molecular subtyping, may improve outbreak detection. PMID:25427666

  9. Twenty years of operation of WWER 440/230 units in Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Tomek, J.

    1998-01-01

    It is twenty years this year since the first unit WWER 440 of Slovak Nuclear Power Plant Jaslovske Bohunice was commissioned. There are four units WWER 440 in operation Jaslovske Bohunice site. First two units of older soviet PWR design V-230 (also known as V-1) and other two units of newer V-213 type (also known as V-2). The goal of this presentation is to summarize and evaluate the operation of Unit 1 and 2 for this period of time and mainly to describe what has been done and what is planned to be done to increase the nuclear safety and operational reliability of both units. The operating organization and regulatory authority assume that an internationally acceptable level of safety will be reached by accomplishing of the upgrading program.(author)

  10. A Distributed Synchronization and Timing System on the EAST Tokamak

    Science.gov (United States)

    Luo, Jiarong; Wu, Yichun; Shu, Yantai

    2008-08-01

    A key requirement for the EAST distributed control system (EASTDCS) is time synchronization to an accuracy of RTOS). The DSTS provides the control and the data acquisition systems with reference clocks (0.01 Hz 10 MHz) and delayed trigger times ( 1 mus 4294 s). These are produced by a Core Module Unit (CMU) connected by optical fibres to many Local Synchronized Node Units (LSNU). The fibres provide immunity from electrical noise and are of equal length to match clock and trigger delays between systems. This paper describes the architecture of the DSTS on the EAST tokamak and provides an overview of the characteristics of the main and local units.

  11. Healthcare Needs of Homeless Youth in the United States

    OpenAIRE

    TERRY, Marisa J; BEDI, Gurpreet; PATEL, Neil

    2010-01-01

    Approximately 1.6 - 2.8 million youth at any given time in the United States are considered homeless and at high risk for poor social and health outcomes. It is estimated that in the United States homelessness overall is expected to rise 10 -20 percent in the next year. While governmental and private programs exist to address the tribulations faced by homeless persons, youth continue to be underserved. The 2009, $787 billion economic stimulus package includes $1.5 billion to address issues...

  12. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2006-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Units 2 that will extend the in-service life of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from the bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  13. An ISOLDE target unit

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    A good dozen different targets are available for ISOLDE, made of different materials and equipped with different kinds of ion-sources, according to the needs of the experiments. Each separator (GPS: general purpose; HRS: high resolution) has its own target. Because of the high radiation levels, robots effect the target changes, about 80 times per year. In the standard unit shown in picture _01, the target is the cylindrical object in the front. It contains uranium-carbide kept at a temperature of 2200 deg C, necessary for the isotopes to be able to escape. At either end, one sees the heater current leads, carrying 700 A. The Booster beam, some 3E13 protons per pulse, enters the target from left. The evaporated isotope atoms enter a hot-plasma ion source (the black object behind the target). The whole unit sits at 60 kV potential (pulsed in synchronism with the arrival of the Booster beam) which accelerates the ions (away from the viewer) towards one of the 2 separators.

  14. [Economic impact of an automated dispensing system in an intensive care unit].

    Science.gov (United States)

    Kheniene, F; Bedouch, P; Durand, M; Marie, F; Brudieu, E; Tourlonnias, M-M; Bongi, P; Allenet, B; Calop, J

    2008-03-01

    Automated dispensing systems (ADS) allow a reduction of medication errors and an improvement of drug distribution in clinical ward. The objective of this study was to evaluate the economic impact of ADS in an intensive care unit. A cost-benefit model was constructed based on the hospital perspective. The system was evaluated before-after implementation of an ADS in a 12-bed cardiovascular intensive care unit of a French teaching hospital: (a) by a measuring nurse and pharmacy technician working time required for various tasks; (b) by measuring the cost of drug storage and the cost of expired drug; (c) by measuring the nurses' acceptability. After ADS was installed, nursing personnel spent less time on medication-related activities (mean of 1.9 hour/day of nursing time). Pharmacy technicians spent more time on floor-stock activities (mean of 0.7 hour/day of technician time). Implementation reduced the cost of drug storage by 56% (14,742 euros) and cost of expired drug by 9,086 euros per year. Finally, cost-benefit analysis including potential savings in terms of working time showed a net benefit of 71,586 euros (14,317 euros/year). The ADS was given high marks by the nurses; 77% wanted to keep it on their unit. Implementation of ADS is expected to generate direct savings for the hospital and working time reallocation, for nurses to interact with patients and for pharmacy technicians to get involved on the ward.

  15. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Kyemin; Jang, Seung-cheol [KAERI, Daejeon (Korea, Republic of); Heo, Gyunyoung [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future.

  16. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    International Nuclear Information System (INIS)

    Oh, Kyemin; Jang, Seung-cheol; Heo, Gyunyoung

    2015-01-01

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future

  17. An Optimization Method of Time Window Based on Travel Time and Reliability

    Directory of Open Access Journals (Sweden)

    Fengjie Fu

    2015-01-01

    Full Text Available The dynamic change of urban road travel time was analyzed using video image detector data, and it showed cyclic variation, so the signal cycle length at the upstream intersection was conducted as the basic unit of time window; there was some evidence of bimodality in the actual travel time distributions; therefore, the fitting parameters of the travel time bimodal distribution were estimated using the EM algorithm. Then the weighted average value of the two means was indicated as the travel time estimation value, and the Modified Buffer Time Index (MBIT was expressed as travel time variability; based on the characteristics of travel time change and MBIT along with different time windows, the time window was optimized dynamically for minimum MBIT, requiring that the travel time change be lower than the threshold value and traffic incidents can be detected real time; finally, travel times on Shandong Road in Qingdao were estimated every 10 s, 120 s, optimal time windows, and 480 s and the comparisons demonstrated that travel time estimation in optimal time windows can exactly and steadily reflect the real-time traffic. It verifies the effectiveness of the optimization method.

  18. Mapping agroecological zones and time lag in vegetation growth by means of Fourier analysis of time series of NDVI images

    Science.gov (United States)

    Menenti, M.; Azzali, S.; Verhoef, W.; Van Swol, R.

    1993-01-01

    Examples are presented of applications of a fast Fourier transform algorithm to analyze time series of images of Normalized Difference Vegetation Index values. The results obtained for a case study on Zambia indicated that differences in vegetation development among map units of an existing agroclimatic map were not significant, while reliable differences were observed among the map units obtained using the Fourier analysis.

  19. Motor unit recruitment patterns 1: responses to changes in locomotor velocity and incline.

    Science.gov (United States)

    Hodson-Tole, Emma F; Wakeling, James M

    2008-06-01

    Mammalian skeletal muscles are composed of a mixture of motor unit types, which contribute a range of mechanical and physiological properties to the muscle. For a muscle to effectively contribute to smooth, co-ordinated movement it must activate an appropriate number and combination of motor units to generate the required force over a suitable time period. Much evidence exists indicating that motor units are activated in an orderly fashion, from the slowest through to the fastest. A growing body of evidence, however, indicates that such a recruitment strategy does not always hold true. Here we investigate how motor unit recruitment patterns were influenced by changes in locomotor velocity and incline. Kinematics data and myoelectric signals were collected from three rat ankle extensor muscles during running on a treadmill at nine velocity and incline combinations. Wavelet and principal component analysis were used to simultaneously decompose the signals into time and frequency space. The relative frequency components of the signals were quantified during 20 time windows of a stride from each locomotor condition. Differences in signal frequency components existed between muscles and locomotor conditions. Faster locomotor velocities led to a relative increase in high frequency components, whereas greater inclines led to a relative increase in the low frequency components. These data were interpreted as representing changes in motor unit recruitment patterns in response to changes in the locomotor demand. Motor units were not always recruited in an orderly manner, indicating that recruitment is a multi-factorial phenomenon that is not yet fully understood.

  20. Load type influences motor unit recruitment in biceps brachii during a sustained contraction.

    Science.gov (United States)

    Baudry, Stéphane; Rudroff, Thorsten; Pierpoint, Lauren A; Enoka, Roger M

    2009-09-01

    Twenty subjects participated in four experiments designed to compare time to task failure and motor-unit recruitment threshold during contractions sustained at 15% of maximum as the elbow flexor muscles either supported an inertial load (position task) or exerted an equivalent constant torque against a rigid restraint (force task). Subcutaneous branched bipolar electrodes were used to record single motor unit activity from the biceps brachii muscle during ramp contractions performed before and at 50 and 90% of the time to failure for the position task during both fatiguing contractions. The time to task failure was briefer for the position task than for the force task (P=0.0002). Thirty and 29 motor units were isolated during the force and position tasks, respectively. The recruitment threshold declined by 48 and 30% (P=0.0001) during the position task for motor units with an initial recruitment threshold below and above the target force, respectively, whereas no significant change in recruitment threshold was observed during the force task. Changes in recruitment threshold were associated with a decrease in the mean discharge rate (-16%), an increase in discharge rate variability (+40%), and a prolongation of the first two interspike intervals (+29 and +13%). These data indicate that there were faster changes in motor unit recruitment and rate coding during the position task than the force task despite a similar net muscle torque during both tasks. Moreover, the results suggest that the differential synaptic input observed during the position task influences most of the motor unit pool.

  1. Using simulated historical time series to prioritize fuel treatments on landscapes across the United States: The LANDFIRE prototype project

    Science.gov (United States)

    Keane, Robert E.; Rollins, Matthew; Zhu, Zhi-Liang

    2007-01-01

    Canopy and surface fuels in many fire-prone forests of the United States have increased over the last 70 years as a result of modern fire exclusion policies, grazing, and other land management activities. The Healthy Forest Restoration Act and National Fire Plan establish a national commitment to reduce fire hazard and restore fire-adapted ecosystems across the USA. The primary index used to prioritize treatment areas across the nation is Fire Regime Condition Class (FRCC) computed as departures of current conditions from the historical fire and landscape conditions. This paper describes a process that uses an extensive set of ecological models to map FRCC from a departure statistic computed from simulated time series of historical landscape composition. This mapping process uses a data-driven, biophysical approach where georeferenced field data, biogeochemical simulation models, and spatial data libraries are integrated using spatial statistical modeling to map environmental gradients that are then used to predict vegetation and fuels characteristics over space. These characteristics are then fed into a landscape fire and succession simulation model to simulate a time series of historical landscape compositions that are then compared to the composition of current landscapes to compute departure, and the FRCC values. Intermediate products from this process are then used to create ancillary vegetation, fuels, and fire regime layers that are useful in the eventual planning and implementation of fuel and restoration treatments at local scales. The complex integration of varied ecological models at different scales is described and problems encountered during the implementation of this process in the LANDFIRE prototype project are addressed.

  2. Unconventional wisdom [Entergy's economic management of five disparate nuclear units

    International Nuclear Information System (INIS)

    Wood, J.

    1996-01-01

    The conventional wisdom is that a competitive nuclear power programme requires standard plants, multi-unit sites and economies of scale. Entergy Operations, Inc (EOI) in the USA has five nuclear units of two reactor types, acquired from five vendors and located on four sites separated by hundreds of miles. EOI set two bench marks in its aim to deliver electricity at the market price from each of its nuclear units while meeting the costs of O and M, fuel, capital investment and overheads. The first was to become the best operator of each type of its differently designed units. The second was to combine the sense of ownership and expertise of single unit operators with the flexibility and efficiency of multi-unit sites. In order to achieve this, EOI aims to operate the five units as though they were on one site. Central to this plan is a set of peer groups, each of which deals with an aspect of plant operation, sharing good practice across all the units. Building on this, increasingly during outages, employees are brought in from other units rather than employing outside contractors. Although EOI employees are more expensive on an hourly basis they are two to three times more efficient than outside contractors. The peer group concept is also leading to rationalisation of expertise as groups become identified with particular specialisations which back-up teams working on other units. (U.K.)

  3. Timing collector

    CERN Document Server

    Schnell, J D

    2006-01-01

    L'unité a pour but de normaliser en signe, en largeur et en amplitude les signaux de timing destinés à être acquis par les DPRAM. Les signaux d'origine, reçus en format blocking (30V), ou TTL (logique positive ou négative) sont transmis en mode différentiel au DPRAM. En option, ils peuvent être transmis parallèlement sur un tiroir auxiliaire lequel redistribue ces signaux aux fins de tests sur son panneau avant.

  4. 1:250,000-scale Hydrologic Units of the United States

    Science.gov (United States)

    Steeves, Peter; Nebert, Douglas

    1994-01-01

    The Geographic Information Retrieval and Analysis System (GIRAS) was developed in the mid 70s to put into digital form a numberof data layers which were of interest to the USGS. One of these data layers was the Hydrologic Units. The map is based on the Hydrologic Unit Maps published by the U.S. Geological Survey Office of Water Data Coordination, together with the list descriptions and name of region, subregion, accounting units, and cataloging unit. The hydrologic units are encoded with an eight-digit number that indicates the hydrologic region (first two digits), hydrologic subregion (second two digits), accounting unit (third two digits), and cataloging unit (fourth two digits). The data produced by GIRAS was originally collected at a scale of 1:250K. Some areas, notably major cities in the west, were recompiled at a scale of 1:100K. In order to join the data together and use the data in a geographic information system (GIS) the data were processed in the ARC/INFO GUS software package. Within the GIS, the data were edgematched and the neatline boundaries between maps were removed to create a single data set for the conterminous

  5. Design of BLDCM emulator for transmission control units

    Science.gov (United States)

    Liu, Chang; He, Yongyi; Zhang, Bodong

    2018-04-01

    According to the testing requirements of the transmission control unit, a brushless DC motor emulating system is designed based on motor simulation and power hardware-in-the-loop. The discrete motor model is established and a real-time numerical method is designed to solve the motor states. The motor emulator directly interacts with power stage of the transmission control unit using a power-efficient circuit topology and is compatible with sensor-less control. Experiments on a laboratory prototype help to verify that the system can emulate the real motor currents and voltages whenever the motor is starting up or suddenly loaded.

  6. On the hazard rate process for imperfectly monitored multi-unit systems

    International Nuclear Information System (INIS)

    Barros, A.; Berenguer, C.; Grall, A.

    2005-01-01

    The aim of this paper is to present a stochastic model to characterize the failure distribution of multi-unit systems when the current units state is imperfectly monitored. The definition of the hazard rate process existing with perfect monitoring is extended to the realistic case where the units failure time are not always detected (non-detection events). The so defined observed hazard rate process gives a better representation of the system behavior than the classical failure rate calculated without any information on the units state and than the hazard rate process based on perfect monitoring information. The quality of this representation is, however, conditioned by the monotony property of the process. This problem is mainly discussed and illustrated on a practical example (two parallel units). The results obtained motivate the use of the observed hazard rate process to characterize the stochastic behavior of the multi-unit systems and to optimize for example preventive maintenance policies

  7. On the hazard rate process for imperfectly monitored multi-unit systems

    Energy Technology Data Exchange (ETDEWEB)

    Barros, A. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France)]. E-mail: anne.barros@utt.fr; Berenguer, C. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France); Grall, A. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France)

    2005-12-01

    The aim of this paper is to present a stochastic model to characterize the failure distribution of multi-unit systems when the current units state is imperfectly monitored. The definition of the hazard rate process existing with perfect monitoring is extended to the realistic case where the units failure time are not always detected (non-detection events). The so defined observed hazard rate process gives a better representation of the system behavior than the classical failure rate calculated without any information on the units state and than the hazard rate process based on perfect monitoring information. The quality of this representation is, however, conditioned by the monotony property of the process. This problem is mainly discussed and illustrated on a practical example (two parallel units). The results obtained motivate the use of the observed hazard rate process to characterize the stochastic behavior of the multi-unit systems and to optimize for example preventive maintenance policies.

  8. A Block-Asynchronous Relaxation Method for Graphics Processing Units

    OpenAIRE

    Anzt, H.; Dongarra, J.; Heuveline, Vincent; Tomov, S.

    2011-01-01

    In this paper, we analyze the potential of asynchronous relaxation methods on Graphics Processing Units (GPUs). For this purpose, we developed a set of asynchronous iteration algorithms in CUDA and compared them with a parallel implementation of synchronous relaxation methods on CPU-based systems. For a set of test matrices taken from the University of Florida Matrix Collection we monitor the convergence behavior, the average iteration time and the total time-to-solution time. Analyzing the r...

  9. The prototype detection unit of the KM3NeT detector

    Science.gov (United States)

    Adrián-Martínez, S.; Ageron, M.; Aharonian, F.; Aiello, S.; Albert, A.; Ameli, F.; Anassontzis, E. G.; Androulakis, G. C.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M.; Avgitas, T.; Balasi, K.; Band, H.; Barbarino, G.; Barbarito, E.; Barbato, F.; Baret, B.; Baron, S.; Barrios, J.; Belias, A.; Berbee, E.; van den Berg, A. M.; Berkien, A.; Bertin, V.; Beurthey, S.; van Beveren, V.; Beverini, N.; Biagi, S.; Biagioni, A.; Bianucci, S.; Billault, M.; Birbas, A.; Boer Rookhuizen, H.; Bormuth, R.; Bouché, V.; Bouhadef, B.; Bourlis, G.; Boutonnet, C.; Bouwhuis, M.; Bozza, C.; Bruijn, R.; Brunner, J.; Cacopardo, G.; Caillat, L.; Calamai, M.; Calvo, D.; Capone, A.; Caramete, L.; Caruso, F.; Cecchini, S.; Ceres, A.; Cereseto, R.; Champion, C.; Château, F.; Chiarusi, T.; Christopoulou, B.; Circella, M.; Classen, L.; Cocimano, R.; Coleiro, A.; Colonges, S.; Coniglione, R.; Cosquer, A.; Costa, M.; Coyle, P.; Creusot, A.; Cuttone, G.; D'Amato, C.; D'Amico, A.; De Bonis, G.; De Rosa, G.; Deniskina, N.; Destelle, J.-J.; Distefano, C.; Di Capua, F.; Donzaud, C.; Dornic, D.; Dorosti-Hasankiadeh, Q.; Drakopoulou, E.; Drouhin, D.; Drury, L.; Durand, D.; Eberl, T.; Elsaesser, D.; Enzenhöfer, A.; Fermani, P.; Fusco, L. A.; Gajanana, D.; Gal, T.; Galatà, S.; Garufi, F.; Gebyehu, M.; Giordano, V.; Gizani, N.; Gracia Ruiz, R.; Graf, K.; Grasso, R.; Grella, G.; Grmek, A.; Habel, R.; van Haren, H.; Heid, T.; Heijboer, A.; Heine, E.; Henry, S.; Hernández-Rey, J. J.; Herold, B.; Hevinga, M. A.; van der Hoek, M.; Hofestädt, J.; Hogenbirk, J.; Hugon, C.; Hößl, J.; Imbesi, M.; James, C. W.; Jansweijer, P.; Jochum, J.; de Jong, M.; Jongen, M.; Kadler, M.; Kalekin, O.; Kappes, A.; Kappos, E.; Katz, U.; Kavatsyuk, O.; Keller, P.; Kieft, G.; Koffeman, E.; Kok, H.; Kooijman, P.; Koopstra, J.; Korporaal, A.; Kouchner, A.; Kreykenbohm, I.; Kulikovskiy, V.; Lahmann, R.; Lamare, P.; Larosa, G.; Lattuada, D.; Le Provost, H.; Leismüller, K. P.; Leisos, A.; Lenis, D.; Leonora, E.; Lindsey Clark, M.; Llorens Alvarez, C. D.; Löhner, H.; Lonardo, A.; Loucatos, S.; Louis, F.; Maccioni, E.; Mannheim, K.; Manolopoulos, K.; Margiotta, A.; Mariş, O.; Markou, C.; Martínez-Mora, J. A.; Martini, A.; Masullo, R.; Melis, K. W.; Michael, T.; Migliozzi, P.; Migneco, E.; Miraglia, A.; Mollo, C. M.; Mongelli, M.; Morganti, M.; Mos, S.; Moudden, Y.; Musico, P.; Musumeci, M.; Nicolaou, C.; Nicolau, C. A.; Orlando, A.; Orzelli, A.; Papaikonomou, A.; Papaleo, R.; Păvălaş, G. E.; Peek, H.; Pellegrino, C.; Pellegriti, M. G.; Perrina, C.; Piattelli, P.; Pikounis, K.; Popa, V.; Pradier, Th.; Priede, M.; Pühlhofer, G.; Pulvirenti, S.; Racca, C.; Raffaelli, F.; Randazzo, N.; Rapidis, P. A.; Razis, P.; Real, D.; Resvanis, L.; Reubelt, J.; Riccobene, G.; Rovelli, A.; Saldaña, M.; Samtleben, D. F. E.; Sanguineti, M.; Santangelo, A.; Sapienza, P.; Schmelling, J.; Schnabel, J.; Sciacca, V.; Sedita, M.; Seitz, T.; Sgura, I.; Simeone, F.; Sipala, V.; Spitaleri, A.; Spurio, M.; Stavropoulos, G.; Steijger, J.; Stolarczyk, T.; Stransky, D.; Taiuti, M.; Terreni, G.; Tézier, D.; Théraube, S.; Thompson, L. F.; Timmer, P.; Trasatti, L.; Trovato, A.; Tselengidou, M.; Tsirigotis, A.; Tzamarias, S.; Tzamariudaki, E.; Vallage, B.; Van Elewyck, V.; Vermeulen, J.; Vernin, P.; Vicini, P.; Viola, S.; Vivolo, D.; Werneke, P.; Wiggers, L.; Wilms, J.; de Wolf, E.; van Wooning, R. H. L.; Zonca, E.; Zornoza, J. D.; Zúñiga, J.; Zwart, A.

    2016-02-01

    A prototype detection unit of the KM3NeT deep-sea neutrino telescope has been installed at 3500m depth 80 km offshore the Italian coast. KM3NeT in its final configuration will contain several hundreds of detection units. Each detection unit is a mechanical structure anchored to the sea floor, held vertical by a submerged buoy and supporting optical modules for the detection of Cherenkov light emitted by charged secondary particles emerging from neutrino interactions. This prototype string implements three optical modules with 31 photomultiplier tubes each. These optical modules were developed by the KM3NeT Collaboration to enhance the detection capability of neutrino interactions. The prototype detection unit was operated since its deployment in May 2014 until its decommissioning in July 2015. Reconstruction of the particle trajectories from the data requires a nanosecond accuracy in the time calibration. A procedure for relative time calibration of the photomultiplier tubes contained in each optical module is described. This procedure is based on the measured coincidences produced in the sea by the ^{40}K background light and can easily be expanded to a detector with several thousands of optical modules. The time offsets between the different optical modules are obtained using LED nanobeacons mounted inside them. A set of data corresponding to 600 h of livetime was analysed. The results show good agreement with Monte Carlo simulations of the expected optical background and the signal from atmospheric muons. An almost background-free sample of muons was selected by filtering the time correlated signals on all the three optical modules. The zenith angle of the selected muons was reconstructed with a precision of about 3°.

  10. The influence of social stress on time perception and psychophysiological reactivity.

    Science.gov (United States)

    van Hedger, Kathryne; Necka, Elizabeth A; Barakzai, Anam K; Norman, Greg J

    2017-05-01

    Time perception is a fundamental component of everyday life. Although time can be measured using standard units, the relationship between an individual's experience of perceived time and a standard unit is highly sensitive to context. Stressful and threatening stimuli have been previously shown to produce time distortion effects, such that individuals perceive the stimuli as lasting for different amounts of time as compared to a standard unit. As a highly social species, humans are acutely sensitive to social stressors; however, time distortion effects have not been studied in the context of social stress. We collected psychophysiological (electrocardiogram and impedance cardiography) and time perception data before, during, and after a modified version of the Trier Social Stress Test for 42 participants. Based on prior theories and evidence from the time perception literature, we hypothesized that experiencing a stressful event would result in time distortion. This hypothesis was supported by the data, with individuals on average reproducing short and long duration negative and positive stimuli as lasting longer after experiencing social stress, t(41) = -3.55, p = .001, and t(41) = -4.12, p social stress. These findings are in line with some other studies of time distortion, and provide evidence for the interoceptive salience model of time perception. Implications for mechanisms of time distortion are discussed. © 2017 Society for Psychophysiological Research.

  11. Unit evaluation at Yucca Mountain, Nevada Test Site: summary report and recommendation

    International Nuclear Information System (INIS)

    Johnstone, J.K.; Peters, R.R.; Gnirk, P.F.

    1984-06-01

    Of the four potential repository units, identified at Yucca Mountain, two potential units the welded, devitrified portions of the Bullfrog and Tram Members of the Crater Flat Tuff are below the water table. The welded, devitrified Topopah Spring Member of the Paintbrush Tuff and the nonwelded, zeolitized Tuffaceous Beds of Calico Hills are above the water table. The results of a study of the four potential repository units are to provide a technical basis for selecting a single target repository unit for future test and evaluation. The unit evaluation studies compared the units rather than provided and absolute assessment. The four ranking evaluation criteria used were: radionuclide isolation time; allowable repository gross thermal loading; excavation stability; and relative economics. Considered the most important of the criteria as well as the most difficult, radionuclide isolation times were estimated using the limited existing data. The allowable repository gross thermal loadings determined from near-field calculations, were nearly the same for all four units. The gross thermal loading supported other criteria by providing the heat source for succeeding thermally related evaluation studies. A large number of studies evaluated excavation stability, including near-field mechanical and thermomechanical finite element code calculations studies. A large number of studies evaluated excavation stability, including near-field mechanical and thermomechanical finite element code calculations, rock matrix property evaluation, and rock mass classification. Relative economics, a minor criterion, did not play an explicit role in the final ranking. Based on all of the analyses, the final recommendation was that the Topopah Springs be selected as the target unit, followed, in order, by the Calico Hills, Bullfrog, and Tram

  12. Does a specialist unit improve outcomes for hospitalized patients with Parkinson's disease?

    Science.gov (United States)

    Skelly, Rob; Brown, Lisa; Fakis, Apostolos; Kimber, Lindsey; Downes, Charlotte; Lindop, Fiona; Johnson, Clare; Bartliff, Caroline; Bajaj, Nin

    2014-01-01

    Objective Suboptimal management of Parkinson's disease (PD) medication in hospital may lead to avoidable complications. We introduced an in-patient PD unit for those admitted urgently with general medical problems. We explored the effect of the unit on medication management, length of stay and patient experience. Methods We conducted a single-center prospective feasibility study. The unit's core features were defined following consultation with patients and professionals: specially trained staff, ready availability of PD drugs, guidelines, and care led by a geriatrician with specialty PD training. Mandatory staff training comprised four 1 h sessions: PD symptoms; medications; therapy; communication and swallowing. Most medication was prescribed using an electronic Prescribing and Administration system (iSOFT) which provided accurate data on time of administration. We compared patient outcomes before and after introduction of the unit. Results The general ward care (n = 20) and the Specialist Parkinson's Unit care (n = 24) groups had similar baseline characteristics. On the specialist unit: less Parkinson's medication was omitted (13% vs 20%, p < 0.001); of the medication that was given, more was given on time (64% vs 50%, p < 0.001); median length of stay was shorter (9 days vs 13 days, p = 0.043) and patients' experience of care was better (p = 0.01). Discussion If replicated and generalizable to other hospitals, reductions in length of stay would lead to significant cost savings. The apparent improved outcomes with Parkinson's unit care merit further investigation. We hope to test the hypothesis that specialized units are cost-effective and improve patient care using a randomized controlled trial design. PMID:25264022

  13. Multi-Unit Initiating Event Analysis for a Single-Unit Internal Events Level 1 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong San; Park, Jin Hee; Lim, Ho Gon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The Fukushima nuclear accident in 2011 highlighted the importance of considering the risks from multi-unit accidents at a site. The ASME/ANS probabilistic risk assessment (PRA) standard also includes some requirements related to multi-unit aspects, one of which (IE-B5) is as follows: 'For multi-unit sites with shared systems, DO NOT SUBSUME multi-unit initiating events if they impact mitigation capability [1].' However, the existing single-unit PSA models do not explicitly consider multi-unit initiating events and hence systems shared by multiple units (e.g., alternate AC diesel generator) are fully credited for the single unit and ignores the need for the shared systems by other units at the same site [2]. This paper describes the results of the multi-unit initiating event (IE) analysis performed as a part of the at-power internal events Level 1 probabilistic safety assessment (PSA) for an OPR1000 single unit ('reference unit'). In this study, a multi-unit initiating event analysis for a single-unit PSA was performed, and using the results, dual-unit LOOP initiating event was added to the existing PSA model for the reference unit (OPR1000 type). Event trees were developed for dual-unit LOOP and dual-unit SBO which can be transferred from dual- unit LOOP. Moreover, CCF basic events for 5 diesel generators were modelled. In case of simultaneous SBO occurrences in both units, this study compared two different assumptions on the availability of the AAC D/G. As a result, when dual-unit LOOP initiating event was added to the existing single-unit PSA model, the total CDF increased by 1∼ 2% depending on the probability that the AAC D/G is available to a specific unit in case of simultaneous SBO in both units.

  14. Survey of regulatory agency review of generating unit performance

    International Nuclear Information System (INIS)

    Roach, E.M. Jr.; Tarletz, D.B.

    1985-01-01

    Regulatory agencies across the country are being called upon increasingly to monitor the management of electric utilities. Such activity, which once was relatively rare, is now common. Most frequently this oversight centers around the operating performance of generating units, both nuclear and fossil. There are, perhaps, several reasons for this increased interest in the efficient operation of generating units: increased fuel costs and fuel cost differentials, increased lead times and costs for construction of new generating units, and increased dependence on existing units because of construction programs being revised to meet decreased load growth. The monitoring of generating units has taken the form of after the fact evaluation of performance on a case-by-case basis and the implementation of productivity incentive programs. Performance standards are used in these contexts both to measure the adequacy of unit performance and to implement incentives in the form of rewards or penalties. The standard used may be a subjective test of prudent performance or some numerical index of plant performance, e.g., equivalent availability, capacity factor or heat rate. Some of the activity by regulators is reviewed in applying subjective and numerical standards and the considerations involved in applying such standards are discussed

  15. Day-Ahead Coordination of Vehicle-to-Grid Operation and Wind Power in Security Constraints Unit Commitment (SCUC)

    OpenAIRE

    Mohammad Javad Abdollahi; Majid Moazzami

    2015-01-01

    In this paper security constraints unit commitment (SCUC) in the presence of wind power resources and electrical vehicles to grid is presented. SCUC operation prepare an optimal time table for generation unit commitment in order to maximize security, minimize operation cost and satisfy the constraints of networks and units in a period of time, as one of the most important research interest in power systems. Today, the relationship between power network and energy storage systems is interested...

  16. SI units in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Iyer, P S [Bhabha Atomic Research Centre, Bombay (India). Div. of Radiation Protection

    1978-11-01

    The proposal of the International Commission on Radiation Units and Measurements that the special units of radiation and radioactivity-roentgen, rad, rem and curie-be replaced by the International System (SI) of Units has been accepted by international bodies. This paper reviews the resons for introducing the new units and their features. The relation between the special units and the corresponding SI units is discussed with examples. In spite of anticipated difficulties, the commission recommends a smooth and efficient changeover to the SI units in ten years.

  17. Systematic test on fast time resolution parallel plate avalanche counter

    International Nuclear Information System (INIS)

    Chen Yu; Li Guangwu; Gu Xianbao; Chen Yanchao; Zhang Gang; Zhang Wenhui; Yan Guohong

    2011-01-01

    Systematic test on each detect unit of parallel plate avalanche counter (PPAC) used in the fission multi-parameter measurement was performed with a 241 Am α source to get the time resolution and position resolution. The detectors work at 600 Pa flowing isobutane and with-600 V on cathode. The time resolution was got by TOF method and the position resolution was got by delay line method. The time resolution of detect units is better than 400 ps, and the position resolution is 6 mm. The results show that the demand of measurement is fully covered. (authors)

  18. Admission time to hospital: a varying standard for a critical definition for admissions to an intensive care unit from the emergency department.

    Science.gov (United States)

    Nanayakkara, Shane; Weiss, Heike; Bailey, Michael; van Lint, Allison; Cameron, Peter; Pilcher, David

    2014-11-01

    Time spent in the emergency department (ED) before admission to hospital is often considered an important key performance indicator (KPI). Throughout Australia and New Zealand, there is no standard definition of 'time of admission' for patients admitted through the ED. By using data submitted to the Australian and New Zealand Intensive Care Society Adult Patient Database, the aim was to determine the differing methods used to define hospital admission time and assess how these impact on the calculation of time spent in the ED before admission to an intensive care unit (ICU). Between March and December of 2010, 61 hospitals were contacted directly. Decision methods for determining time of admission to the ED were matched to 67,787 patient records. Univariate and multivariate analyses were conducted to assess the relationship between decision method and the reported time spent in the ED. Four mechanisms of recording time of admission were identified, with time of triage being the most common (28/61 hospitals). Reported median time spent in the ED varied from 2.5 (IQR 0.83-5.35) to 5.1 h (2.82-8.68), depending on the decision method. After adjusting for illness severity, hospital type and location, decision method remained a significant factor in determining measurement of ED length of stay. Different methods are used in Australia and New Zealand to define admission time to hospital. Professional bodies, hospitals and jurisdictions should ensure standardisation of definitions for appropriate interpretation of KPIs as well as for the interpretation of studies assessing the impact of admission time to ICU from the ED. WHAT IS KNOWN ABOUT THE TOPIC?: There are standards for the maximum time spent in the ED internationally, but these standards vary greatly across Australia. The definition of such a standard is critically important not only to patient care, but also in the assessment of hospital outcomes. Key performance indicators rely on quality data to improve decision

  19. Equivalent unit in telecommunications services

    Directory of Open Access Journals (Sweden)

    Luiza Santangelo Reis

    2016-03-01

    Full Text Available The aim of this study is to analyze the relationship between the “cost” and “production” variables in a telecommunications company, measuring the latter in the unit of measure termed Network Units (NU.  The study shows a Pearson correlation coefficient of 0.55 -evaluated as moderate - over the course of a 24-month period and resulting from 177 trials.  Subsequently, only the work teams composed of the company´s standard structure were taken into consideration, which yielded 32 observations of interest and a derived correlation coefficient of 0.8.  Finally, the data pertaining to each individual work team over a determined length of time was analyzed, showing strong correlation coefficients in seven of the eleven, and in the remainder, a moderate linear relationship between the variables analyzed.  These results suggest the viability of applying the NU production measurement model in the telecommunications company in question

  20. Some performance characteristics of a fluidized bed heat recovery unit

    International Nuclear Information System (INIS)

    Militzer, J.; Basu, P.; Adaikkappan, N.

    1985-01-01

    The advantages of using fluidized bed heat recovery units with diesel engines are well documented. Two of those are: significantly less tube fouling and heat transfer coefficient four to five time higher than that of conventional shell and tube heat exchangers. The high concentration of soot in the exhaust gases of diesel engines make fouling a major concern in design of any kind of heat recovery unit. In the experiment a conventional fluidized bed heat exchanger was connected to the exhaust of a diesel engine mounted on a dynamometer. With this arrangement it was possible to test the heat recovery unit under a wide range of operating conditions. The main objective of this experiment was the determination of the performance characteristics of the heat recovery unit, especially with reference to its heat transfer and fouling characteristics. (author)

  1. United States position on severe accidents

    International Nuclear Information System (INIS)

    Ross, D.F.

    1988-01-01

    The United States policy on severe accidents was published in 1985 for both new plant applications and for existing plants. Implementation of this policy is in progress. This policy, aided by a related safety goal policy and by analysis capabilities emerging from improved understanding of accident phenomenology, is viewed as a logical development from the pioneering work in the WASH-1400 Reactor Safety Study published by the United States Nuclear Regulatory Commission (NRC) in 1975. This work provided an estimate of the probability and consequences of severe accidents which, prior to that time, had been mostly evaluated by somewhat arbitrary assumptions dating back 30 years. The early history of severe accident evaluation is briefly summarized for the period 1957-1979. Then, the galvanizing action of Three Mile Island Unit 2 (TMI-2) on severe accident analysis, experimentation and regulation is reviewed. Expressions of US policy in the form of rulemaking, severe accident policy, safety research, safety goal policy and court decisions (on adequacy of safety) are discussed. Finally, the NRC policy as of March 1988 is stated, along with a prospective look at the next few years. (author). 19 refs

  2. Longitude Position in a Time Zone and Cancer Risk in the United States.

    Science.gov (United States)

    Gu, Fangyi; Xu, Shangda; Devesa, Susan S; Zhang, Fanni; Klerman, Elizabeth B; Graubard, Barry I; Caporaso, Neil E

    2017-08-01

    Background: Circadian disruption is a probable human carcinogen. From the eastern to western border of a time zone, social time is equal, whereas solar time is progressively delayed, producing increased discrepancies between individuals' social and biological circadian time. Accordingly, western time zone residents experience greater circadian disruption and may be at an increased risk of cancer. Methods: We examined associations between the position in a time zone and age-standardized county-level incidence rates for total cancers combined and 23 specific cancers by gender using the data of the Surveillance, Epidemiology, and End Results Program (2000-2012), including four million cancer diagnoses in white residents of 607 counties in 11 U.S. states. Log-linear regression was conducted, adjusting for latitude, poverty, cigarette smoking, and state. Bonferroni-corrected P values were used as the significance criteria. Results: Risk increased from east to west within a time zone for total and for many specific cancers, including chronic lymphocytic leukemia (both genders) and cancers of the stomach, liver, prostate, and non-Hodgkin lymphoma in men and cancers of the esophagus, colorectum, lung, breast, and corpus uteri in women. Conclusions: Risk increased from the east to the west in a time zone for total and many specific cancers, in accord with the circadian disruption hypothesis. Replications in analytic epidemiologic studies are warranted. Impact: Our findings suggest that circadian disruption may not be a rare phenomenon affecting only shift workers, but is widespread in the general population with broader implications for public health than generally appreciated. Cancer Epidemiol Biomarkers Prev; 26(8); 1306-11. ©2017 AACR . ©2017 American Association for Cancer Research.

  3. Integrated risk assessment for multi-unit NPP sites—A comparison

    International Nuclear Information System (INIS)

    Kumar, C. Senthil; Hassija, Varun; Velusamy, K.; Balasubramaniyan, V.

    2015-01-01

    Highlights: • Framework for integrated risk assessment for multi-unit NPP sites. • Categorization of external and internal events. • Modelling of key issues: mission time, cliff-edge, common cause failures, etc. • Safety goals for multi-unit NPP sites. • Comparison of site core damage frequency in one, two, three and four unit sites. - Abstract: Most of the nuclear power producing sites in the world houses multiple units. Such sites are faced with hazards generated from external events: earthquake, tsunami, flood, etc. and can threaten the safety of nuclear power plants. Further, risk from a multiple unit site and its impact on the public and environment was evident during the Fukushima nuclear disaster in March 2011. It is therefore important to evolve a methodology to systematically assess the risk from multi-unit site. For a single unit site, probabilistic risk assessment technique identifies the potential accident scenarios, their consequences, and estimates the core damage frequency that arise due to internal and external hazards. This challenging task becomes even more complex for a multiple unit site, especially when the external hazards that has the potential to generate one or more correlated hazards or a combination of non-correlated hazards are to be modelled. This paper presents an approach to evaluate risk for multiple NPP sites and also compare the risk for sites housing single, double and multiple nuclear plants.

  4. Integrated risk assessment for multi-unit NPP sites—A comparison

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, C. Senthil, E-mail: cskumar@igcar.gov.in [AERB-Safety Research Institute, Kalpakkam (India); Hassija, Varun; Velusamy, K. [Reactor Design Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India); Balasubramaniyan, V. [AERB-Safety Research Institute, Kalpakkam (India)

    2015-11-15

    Highlights: • Framework for integrated risk assessment for multi-unit NPP sites. • Categorization of external and internal events. • Modelling of key issues: mission time, cliff-edge, common cause failures, etc. • Safety goals for multi-unit NPP sites. • Comparison of site core damage frequency in one, two, three and four unit sites. - Abstract: Most of the nuclear power producing sites in the world houses multiple units. Such sites are faced with hazards generated from external events: earthquake, tsunami, flood, etc. and can threaten the safety of nuclear power plants. Further, risk from a multiple unit site and its impact on the public and environment was evident during the Fukushima nuclear disaster in March 2011. It is therefore important to evolve a methodology to systematically assess the risk from multi-unit site. For a single unit site, probabilistic risk assessment technique identifies the potential accident scenarios, their consequences, and estimates the core damage frequency that arise due to internal and external hazards. This challenging task becomes even more complex for a multiple unit site, especially when the external hazards that has the potential to generate one or more correlated hazards or a combination of non-correlated hazards are to be modelled. This paper presents an approach to evaluate risk for multiple NPP sites and also compare the risk for sites housing single, double and multiple nuclear plants.

  5. Hardware interface unit for control of shuttle RMS vibrations

    Science.gov (United States)

    Lindsay, Thomas S.; Hansen, Joseph M.; Manouchehri, Davoud; Forouhar, Kamran

    1994-01-01

    Vibration of the Shuttle Remote Manipulator System (RMS) increases the time for task completion and reduces task safety for manipulator-assisted operations. If the dynamics of the manipulator and the payload can be physically isolated, performance should improve. Rockwell has developed a self contained hardware unit which interfaces between a manipulator arm and payload. The End Point Control Unit (EPCU) is built and is being tested at Rockwell and at the Langley/Marshall Coupled, Multibody Spacecraft Control Research Facility in NASA's Marshall Space Flight Center in Huntsville, Alabama.

  6. Life quality time allocation index-an equilibrium economy consistent version of the current life quality index

    DEFF Research Database (Denmark)

    Ditlevsen, Ove; Friis-Hansen, Peter

    2005-01-01

    The definition the Life Quality Index for a country as originally suggested by Nathwani, Lind and Pandey is based on the gross domestic product (GDP), the expected life in good health at birth, and the fraction of life time the anonymous citizen of the country is occupied with money making work...... a further development casting the definition into dimensionless quantities that make the index get a pure unit of time and not the somewhat obscure unit as a power product of a money unit and a time unit. To avoid confusion, this new variant of the LQI is called the Life Quality Time Allocation Index (LQTAI...... of the variables themselves, the relative increment of the LQI becomes defined as a convex combination of the two relative increments. The combination parameter is obtained by an optimality argument about the anonymous citizen’s distribution of his or her time between free time and work time. In the original...

  7. Off-Policy Reinforcement Learning: Optimal Operational Control for Two-Time-Scale Industrial Processes.

    Science.gov (United States)

    Li, Jinna; Kiumarsi, Bahare; Chai, Tianyou; Lewis, Frank L; Fan, Jialu

    2017-12-01

    Industrial flow lines are composed of unit processes operating on a fast time scale and performance measurements known as operational indices measured at a slower time scale. This paper presents a model-free optimal solution to a class of two time-scale industrial processes using off-policy reinforcement learning (RL). First, the lower-layer unit process control loop with a fast sampling period and the upper-layer operational index dynamics at a slow time scale are modeled. Second, a general optimal operational control problem is formulated to optimally prescribe the set-points for the unit industrial process. Then, a zero-sum game off-policy RL algorithm is developed to find the optimal set-points by using data measured in real-time. Finally, a simulation experiment is employed for an industrial flotation process to show the effectiveness of the proposed method.

  8. Homosexuality, Manliness and the United States

    Science.gov (United States)

    2010-03-25

    units upon completion of basic and advanced training. Nowadays, most servicemembers live in apartment style quarters, where they may share...grown up in an era where differing sexual orientation was far more acceptable than in previous generations, which subsequently leads to the second...changed over time from pre- Victorian to World War I. Focusing the majority of his research on Canadian youth in Ontario during the build-up to World

  9. Hidden power system inflexibilities imposed by traditional unit commitment formulations

    International Nuclear Information System (INIS)

    Morales-España, Germán; Ramírez-Elizondo, Laura; Hobbs, Benjamin F.

    2017-01-01

    Highlights: • Quality and accuracy of traditional-energy- and power-based UCs are evaluated. • Real-time performance evaluation simulating “perfect” stochastic UCs. • Ideal energy-based stochastic UC formulations impose hidden system inflexibilities. • A deterministic power-based UC may outperform an ideal energy-based stochastic UC. • Power-based UC overcomes flaws of energy-based UC: lower cost and wind curtailment. - Abstract: Approximations made in traditional day-ahead unit commitment model formulations can result in suboptimal or even infeasible schedules for slow-start units and inaccurate predictions of actual costs and wind curtailment. With increasing wind penetration, these errors will become economically more significant. Here, we consider inaccuracies from three approximations: the use of hourly intervals in which energy production from each generator is modeled as being constant; the disregarding of startup and shutdown energy trajectories; and optimization based on expected wind profiles. The results of unit commitment formulations with those assumptions are compared to models that: (1) use a piecewise-linear power profiles of generation, load and wind, instead of the traditional stepwise energy profiles; (2) consider startup/shutdown trajectories; and (3) include many possible wind trajectories in a stochastic framework. The day-ahead hourly schedules of slow-start generators are then evaluated against actual wind and load profiles using a model real-time dispatch and quick-start unit commitment with a 5 min time step. We find that each simplification usually causes expected generation costs to increase by several percentage points, and results in significant understatement of expected wind curtailment and, in some cases, load interruptions. The inclusion of startup and shutdown trajectories often yielded the largest improvements in schedule performance.

  10. On Throughput Maximization in Constant Travel-Time Robotic Cells

    OpenAIRE

    Milind Dawande; Chelliah Sriskandarajah; Suresh Sethi

    2002-01-01

    We consider the problem of scheduling operations in bufferless robotic cells that produce identical parts. The objective is to find a cyclic sequence of robot moves that minimizes the long-run average time to produce a part or, equivalently, maximizes the throughput rate. The robot can be moved in simple cycles that produce one unit or, in more complicated cycles, that produce multiple units. Because one-unit cycles are the easiest to understand, implement, and control, they are widely used i...

  11. A cost effective model for appropriate administration of red cell units and salvaging un-transfused red cell units by using temperature sensitive indicators for blood component transportation in a hospital setting

    Directory of Open Access Journals (Sweden)

    Aseem K Tiwari

    2015-01-01

    Full Text Available Background: A rule called "30-min rule" defines that red cell unit cannot be used if it has been out of blood bank refrigerator for over 30 min. This rule is useful to guide initiation of transfusion, but is inadequate for deciding whether to reuse or discard units received-back at blood transfusion services (BTS. A simple cost-effective temperature-sensitive indicator was evaluated to decide upon reuse (cold chain was uninterrupted or discard (where cold chain was interrupted in a simulation exercise. Materials and Methods: Temperature-sensitive indicators TH-F™ that irreversibly changed color from white to red demonstrated that heat excursion has occurred and the cumulative temperature has exceeded 10°C for over 30 min, were used in outdated red cells for simulating units, which are not used and received-back. These units were also tagged with a standard temperature monitoring device, which was a re-usable credit card sized device, which would log the actual time and temperature. In few units percent hemolysis was also calculated. Results: Statistically insignificant elevation in average temperature was noted in 102 simulated units at the time of return to BTS (Δ 0.04°C, despite the fact that these units were in the transport box for over 4 h. The average supernatant hemoglobin in these units was 0.24%, much below the prescribed threshold. Conclusion: Transportation of blood in controlled conditions with temperature-sensitive indicator is a cost-effective model to save blood, a precious human resource.

  12. Developing Boiler Concepts as Integrated Units

    DEFF Research Database (Denmark)

    Sørensen, Kim; Condra, Thomas Joseph; Houbak, Niels

    2004-01-01

    - consisting of pressure part, burner and control system. The Technical University of Denmark, MEK - Energy Engineering Section [12] has participated in the modelling process. The project has included static and dynamic modelling of the boiler concept. For optimization of operation, verication of performance......With the objective to be able to optimize the design and operation of steam boiler concepts Aalborg Industries A/S [1] has together with Aalborg University, Institute of Energy Technology [9] carried out a development project paying special attention to the boiler concept as an integrated unit......, emissions and to obtain long time operation experiences with the boiler concept, a full scale prototype has been built and these tests have been accomplished on the prototype. By applying this integrated unit approach to the boiler concept development it has been possible to optimize the different building...

  13. Tightening unit EZ 250 for VVER 1000 type reactor pressure vessel head flange joints

    International Nuclear Information System (INIS)

    Ruchar, Miloslav; Nadenik, Tomas; Kroj, Ludek

    2010-01-01

    The programme of flange joints tightening by seals made of expanded graphite for VVER 440 and VVER 1000 reactor head flange joints is highlighted, and tightening units of row EZ 650 and EZ 650 TK and KNI for VVER 440 reactor head flange joints and EZ 250 tightening unit for VVER 1000 reactor head flange joints are described in detail. The main advantages of electronically controlled tightening units include: Precise and uniform compression of the gasket during the tightening procedure; Automated solution to the graphite relaxing problem during tightening; Possibility of diagnosis of the thread status of the joints being tightened; Alleviation of operator's tough work; Shorter time of tensioning associated with a lower collective doses; Quick preparation of tightening procedure report from the data measured; Calibration renewal is possible in advance at time of unit storage without the need to place it on a real joint. (P.A.)

  14. United States National Seismographic Network

    International Nuclear Information System (INIS)

    Buland, R.

    1993-09-01

    The concept of a United States National Seismograph Network (USNSN) dates back nearly 30 years. The idea was revived several times over the decades. but never funded. For, example, a national network was proposed and discussed at great length in the so called Bolt Report (U. S. Earthquake Observatories: Recommendations for a New National Network, National Academy Press, Washington, D.C., 1980, 122 pp). From the beginning, a national network was viewed as augmenting and complementing the relatively dense, predominantly short-period vertical coverage of selected areas provided by the Regional Seismograph Networks (RSN's) with a sparse, well-distributed network of three-component, observatory quality, permanent stations. The opportunity finally to begin developing a national network arose in 1986 with discussions between the US Geological Survey (USGS) and the Nuclear Regulatory Commission (NRC). Under the agreement signed in 1987, the NRC has provided $5 M in new funding for capital equipment (over the period 1987-1992) and the USGS has provided personnel and facilities to develop. deploy, and operate the network. Because the NRC funding was earmarked for the eastern United States, new USNSN station deployments are mostly east of 105 degree W longitude while the network in the western United States is mostly made up of cooperating stations (stations meeting USNSN design goals, but deployed and operated by other institutions which provide a logical extension to the USNSN)

  15. 12 CFR 404.5 - Time for processing.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Time for processing. 404.5 Section 404.5 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES INFORMATION DISCLOSURE Procedures for Disclosure of Records Under the Freedom of Information Act. § 404.5 Time for processing. (a) General. Ex-Im Bank...

  16. The prototype detection unit of the KM3NeT detector

    Energy Technology Data Exchange (ETDEWEB)

    Adrian-Martinez, S.; Ardid, M.; Llorens Alvarez, C.D.; Martinez-Mora, J.A.; Saldana, M. [Universitat Politecnica de Valencia, Instituto de Investigacion para la Gestion Integrada de las Zonas Costeras, Gandia (Spain); Ageron, M.; Bertin, V.; Beurthey, S.; Billault, M.; Brunner, J.; Caillat, L.; Cosquer, A.; Coyle, P.; Destelle, J.J.; Dornic, D.; Henry, S.; Keller, P.; Lamare, P.; Tezier, D.; Theraube, S. [Aix Marseille Universite CNRS/IN2P3, CPPM UMR 7346, Marseille (France); Aharonian, F.; Drury, L. [DIAS, Dublin (Ireland); Aiello, S.; Giordano, V.; Leonora, E.; Randazzo, N.; Sipala, V. [INFN, Sezione di Catania, Catania (Italy); Albert, A.; Drouhin, D.; Racca, C. [GRPHE, Universite de Haute Alsace, IUT de Colmar, Colmar (France); Ameli, F.; Biagioni, A.; De Bonis, G.; Lonardo, A.; Nicolau, C.A.; Simeone, F.; Vicini, P. [INFN, Sezione di Roma, Rome (Italy); Anassontzis, E.G.; Resvanis, L. [National and Kapodistrian University of Athens, Deparment of Physics, Athens (Greece); Androulakis, G.C.; Balasi, K.; Belias, A.; Drakopoulou, E.; Kappos, E.; Manolopoulos, K.; Markou, C.; Pikounis, K.; Rapidis, P.A.; Stavropoulos, G.; Tzamariudaki, E. [Institute of Nuclear Physics, NCSR ' ' Demokritos' ' , Athens (Greece); Anghinolfi, M.; Cereseto, R.; Hugon, C.; Musico, P.; Orzelli, A. [INFN, Sezione di Genova, Genova (Italy); Anton, G.; Classen, L.; Eberl, T.; Gal, T.; Graf, K.; Heid, T.; Herold, B.; Hofestaedt, J.; Hoessl, J.; James, C.W.; Kalekin, O.; Kappes, A.; Katz, U.; Lahmann, R.; Reubelt, J.; Schnabel, J.; Seitz, T.; Stransky, D.; Tselengidou, M. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen Centre for Astroparticle Physics, Erlangen (Germany); Anvar, S.; Chateau, F.; Durand, D.; Le Provost, H.; Louis, F.; Moudden, Y.; Zonca, E. [CEA, Irfu/Sedi, Centre de Saclay, Gif-sur-Yvette (France); Avgitas, T.; Baret, B.; Baron, S.; Boutonnet, C.; Champion, C.; Coleiro, A.; Colonges, S.; Creusot, A.; Galata, S.; Gracia Ruiz, R.; Kouchner, A.; Lindsey Clark, M.; Loucatos, S.; Van Elewyck, V. [APC,Universite Paris Diderot, CNRS/IN2P3 CEA/IRFU, Observatoire de Paris, Sorbonne Paris Cite, Paris (France); Band, H.; Berbee, E.; Berkien, A.; Beveren, V. van; Boer Rookhuizen, H.; Bouwhuis, M.; D' Amico, A.; Gajanana, D.; Gebyehu, M.; Heijboer, A.; Heine, E.; Hoek, M. van der; Hogenbirk, J.; Jansweijer, P.; Jongen, M.; Kieft, G.; Kok, H.; Koopstra, J.; Korporaal, A.; Melis, K.W.; Michael, T.; Mos, S.; Peek, H.; Schmelling, J.; Steijger, J.; Timmer, P.; Vermeulen, J.; Werneke, P.; Wiggers, L.; Zwart, A. [Nikhef, Amsterdam (Netherlands); Barbarino, G.; Barbato, F.; De Rosa, G.; Di Capua, F.; Garufi, F.; Vivolo, D. [INFN, Sezione di Napoli, Naples (Italy); Universita ' Federico II' , Dipartimento di Fisica, Naples (Italy); Barbarito, E.; Ceres, A.; Circella, M.; Mongelli, M.; Sgura, I. [INFN, Sezione di Bari, Bari (Italy); Barrios, J.; Calvo, D.; Hernandez-Rey, J.J.; Real, D.; Zornoza, J.D.; Zuniga, J. [CSIC-Universitat de Valencia, IFIC-Instituto de Fisica Corpuscular, Valencia (Spain); Berg, A.M. van den; Dorosti-Hasankiadeh, Q.; Hevinga, M.A.; Kavatsyuk, O.; Loehner, H.; Wooning, R.H.L. van [KVI-CART, University of Groningen, Groningen (Netherlands); Beverini, N. [INFN, Sezione di Pisa, Pisa (Italy); Universita di Pisa, Dipartimento di Fisica, Pisa (Italy); Biagi, S. [INFN, Laboratori Nazionali del Sud, Catania (Italy); Bianucci, S.; Bouhadef, B.; Calamai, M.; Maccioni, E.; Morganti, M.; Raffaelli, F.; Terreni, G. [Universita di Pisa, Dipartimento di Fisica, Pisa (Italy); Birbas, A.; Bourlis, G.; Christopoulou, B.; Gizani, N.; Leisos, A.; Lenis, D.; Tsirigotis, A.; Tzamarias, S. [Hellenic Open University, School of Science and Technology, Patras (Greece); Bormuth, R.; Jong, M. de; Samtleben, D.F.E. [Nikhef, Amsterdam (Netherlands); Leiden University, Leiden Institute of Physics, Leiden (Netherlands); Bouche, V.; Capone, A.; Fermani, P.; Masullo, R.; Perrina, C. [INFN, Sezione di Roma, Rome (Italy); Universita di Roma La Sapienza, Dipartimento di Fisica, Rome (Italy); Bozza, C.; Grella, G. [Universita ' Federico II' , Dipartimento di Fisica, Naples (Italy); Universita di Salerno, Dipartimento di Fisica, Fisciano (Italy); Bruijn, R.; Koffeman, E.; Wolf, E. de [Nikhef, Amsterdam (Netherlands); University of Amsterdam, Institute of Physics, Amsterdam (Netherlands); Cacopardo, G.; Caruso, F.; Cocimano, R.; Coniglione, R.; Costa, M.; Cuttone, G.; D' Amato, C.; Distefano, C.; Grasso, R.; Grmek, A.; Imbesi, M.; Kulikovskiy, V.; Larosa, G.; Lattuada, D.; Leismueller, K.P.; Migneco, E.; Miraglia, A.; Musumeci, M.; Orlando, A.; Papaleo, R.; Pellegriti, M.G.; Collaboration: KM3NeT Collaboration; and others

    2016-02-15

    A prototype detection unit of the KM3NeT deep-sea neutrino telescope has been installed at 3500m depth 80 km offshore the Italian coast. KM3NeT in its final configuration will contain several hundreds of detection units. Each detection unit is a mechanical structure anchored to the sea floor, held vertical by a submerged buoy and supporting optical modules for the detection of Cherenkov light emitted by charged secondary particles emerging from neutrino interactions. This prototype string implements three optical modules with 31 photomultiplier tubes each. These optical modules were developed by the KM3NeT Collaboration to enhance the detection capability of neutrino interactions. The prototype detection unit was operated since its deployment in May 2014 until its decommissioning in July 2015. Reconstruction of the particle trajectories from the data requires a nanosecond accuracy in the time calibration. A procedure for relative time calibration of the photomultiplier tubes contained in each optical module is described. This procedure is based on the measured coincidences produced in the sea by the {sup 40}K background light and can easily be expanded to a detector with several thousands of optical modules. The time offsets between the different optical modules are obtained using LED nanobeacons mounted inside them. A set of data corresponding to 600 h of livetime was analysed. The results show good agreement with Monte Carlo simulations of the expected optical background and the signal from atmospheric muons. An almost background-free sample of muons was selected by filtering the time correlated signals on all the three optical modules. The zenith angle of the selected muons was reconstructed with a precision of about 3 {sup circle}. (orig.)

  17. The prototype detection unit of the KM3NeT detector

    International Nuclear Information System (INIS)

    Adrian-Martinez, S.; Ardid, M.; Llorens Alvarez, C.D.; Martinez-Mora, J.A.; Saldana, M.; Ageron, M.; Bertin, V.; Beurthey, S.; Billault, M.; Brunner, J.; Caillat, L.; Cosquer, A.; Coyle, P.; Destelle, J.J.; Dornic, D.; Henry, S.; Keller, P.; Lamare, P.; Tezier, D.; Theraube, S.; Aharonian, F.; Drury, L.; Aiello, S.; Giordano, V.; Leonora, E.; Randazzo, N.; Sipala, V.; Albert, A.; Drouhin, D.; Racca, C.; Ameli, F.; Biagioni, A.; De Bonis, G.; Lonardo, A.; Nicolau, C.A.; Simeone, F.; Vicini, P.; Anassontzis, E.G.; Resvanis, L.; Androulakis, G.C.; Balasi, K.; Belias, A.; Drakopoulou, E.; Kappos, E.; Manolopoulos, K.; Markou, C.; Pikounis, K.; Rapidis, P.A.; Stavropoulos, G.; Tzamariudaki, E.; Anghinolfi, M.; Cereseto, R.; Hugon, C.; Musico, P.; Orzelli, A.; Anton, G.; Classen, L.; Eberl, T.; Gal, T.; Graf, K.; Heid, T.; Herold, B.; Hofestaedt, J.; Hoessl, J.; James, C.W.; Kalekin, O.; Kappes, A.; Katz, U.; Lahmann, R.; Reubelt, J.; Schnabel, J.; Seitz, T.; Stransky, D.; Tselengidou, M.; Anvar, S.; Chateau, F.; Durand, D.; Le Provost, H.; Louis, F.; Moudden, Y.; Zonca, E.; Avgitas, T.; Baret, B.; Baron, S.; Boutonnet, C.; Champion, C.; Coleiro, A.; Colonges, S.; Creusot, A.; Galata, S.; Gracia Ruiz, R.; Kouchner, A.; Lindsey Clark, M.; Loucatos, S.; Van Elewyck, V.; Band, H.; Berbee, E.; Berkien, A.; Beveren, V. van; Boer Rookhuizen, H.; Bouwhuis, M.; D'Amico, A.; Gajanana, D.; Gebyehu, M.; Heijboer, A.; Heine, E.; Hoek, M. van der; Hogenbirk, J.; Jansweijer, P.; Jongen, M.; Kieft, G.; Kok, H.; Koopstra, J.; Korporaal, A.; Melis, K.W.; Michael, T.; Mos, S.; Peek, H.; Schmelling, J.; Steijger, J.; Timmer, P.; Vermeulen, J.; Werneke, P.; Wiggers, L.; Zwart, A.; Barbarino, G.; Barbato, F.; De Rosa, G.; Di Capua, F.; Garufi, F.; Vivolo, D.; Barbarito, E.; Ceres, A.; Circella, M.; Mongelli, M.; Sgura, I.; Barrios, J.; Calvo, D.; Hernandez-Rey, J.J.; Real, D.; Zornoza, J.D.; Zuniga, J.; Berg, A.M. van den; Dorosti-Hasankiadeh, Q.; Hevinga, M.A.; Kavatsyuk, O.; Loehner, H.; Wooning, R.H.L. van; Beverini, N.; Biagi, S.; Bianucci, S.; Bouhadef, B.; Calamai, M.; Maccioni, E.; Morganti, M.; Raffaelli, F.; Terreni, G.; Birbas, A.; Bourlis, G.; Christopoulou, B.; Gizani, N.; Leisos, A.; Lenis, D.; Tsirigotis, A.; Tzamarias, S.; Bormuth, R.; Jong, M. de; Samtleben, D.F.E.; Bouche, V.; Capone, A.; Fermani, P.; Masullo, R.; Perrina, C.; Bozza, C.; Grella, G.; Bruijn, R.; Koffeman, E.; Wolf, E. de; Cacopardo, G.; Caruso, F.; Cocimano, R.; Coniglione, R.; Costa, M.; Cuttone, G.; D'Amato, C.; Distefano, C.; Grasso, R.; Grmek, A.; Imbesi, M.; Kulikovskiy, V.; Larosa, G.; Lattuada, D.; Leismueller, K.P.; Migneco, E.; Miraglia, A.; Musumeci, M.; Orlando, A.; Papaleo, R.; Pellegriti, M.G.

    2016-01-01

    A prototype detection unit of the KM3NeT deep-sea neutrino telescope has been installed at 3500m depth 80 km offshore the Italian coast. KM3NeT in its final configuration will contain several hundreds of detection units. Each detection unit is a mechanical structure anchored to the sea floor, held vertical by a submerged buoy and supporting optical modules for the detection of Cherenkov light emitted by charged secondary particles emerging from neutrino interactions. This prototype string implements three optical modules with 31 photomultiplier tubes each. These optical modules were developed by the KM3NeT Collaboration to enhance the detection capability of neutrino interactions. The prototype detection unit was operated since its deployment in May 2014 until its decommissioning in July 2015. Reconstruction of the particle trajectories from the data requires a nanosecond accuracy in the time calibration. A procedure for relative time calibration of the photomultiplier tubes contained in each optical module is described. This procedure is based on the measured coincidences produced in the sea by the 40 K background light and can easily be expanded to a detector with several thousands of optical modules. The time offsets between the different optical modules are obtained using LED nanobeacons mounted inside them. A set of data corresponding to 600 h of livetime was analysed. The results show good agreement with Monte Carlo simulations of the expected optical background and the signal from atmospheric muons. An almost background-free sample of muons was selected by filtering the time correlated signals on all the three optical modules. The zenith angle of the selected muons was reconstructed with a precision of about 3 circle . (orig.)

  18. Discharge from an emergency department observation unit and a surgical assessment unit

    DEFF Research Database (Denmark)

    Schultz, Helen; Qvist, Niels; Backer Mogensen, Christian

    2014-01-01

    To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit.......To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit....

  19. Judicial Process, Grade Eight. Resource Unit (Unit V).

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    This resource unit, developed by the University of Minnesota's Project Social Studies, introduces eighth graders to the judicial process. The unit was designed with two major purposes in mind. First, it helps pupils understand judicial decision-making, and second, it provides for the study of the rights guaranteed by the federal Constitution. Both…

  20. Babies born before arrival to hospital and maternity unit closures in Queensland and Australia.

    Science.gov (United States)

    Kildea, Sue; McGhie, Alexandra C; Gao, Yu; Rumbold, Alice; Rolfe, Margaret

    2015-09-01

    Evidence suggests the closure of maternity units is associated with an increase in babies born before arrival (BBA). To explore the association between the number of maternity units in Australia and Queensland by birthing numbers, BBA rate and geographic remoteness of the health district where the mother lives. A retrospective study utilised routinely collected perinatal data (1992-2011). Pearson correlation tested the relationship between BBA rate and number of maternity units. Linear regression examined this association over time. During 1992-2011, the absolute numbers (N=22,814) of women having a BBA each year in Australia increased by 47% (N=836-1233); and 206% (n=140-429) in Queensland. This coincided with a 41% reduction in maternity units in Australia (N=623-368=18 per year) and a 28% reduction in Queensland (n=129-93). BBA rates increased significantly across Australia, r=0.837, n=20 years, pmaternity units in Australia, r=-0.804, n=19 years, pmaternity units over a 20-year period across Australia and Queensland is significantly associated with increased BBA rates. The distribution is not limited to rural and remote areas. Given the high risk of adverse maternal and neonatal outcomes associated with BBA, it is time to revisit the closure of units. Copyright © 2015 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  1. The organization of human epidermis: functional epidermal units and phi proportionality.

    Science.gov (United States)

    Hoath, Steven B; Leahy, D G

    2003-12-01

    The concept that mammalian epidermis is structurally organized into functional epidermal units has been proposed on the basis of stratum corneum (SC) architecture, proliferation kinetics, melanocyte:keratinocyte ratios (1:36), and, more recently, Langerhans cell: epidermal cell ratios (1:53). This article examines the concept of functional epidermal units in human skin in which the maintenance of phi (1.618034) proportionality provides a central organizing principle. The following empirical measurements were used: 75,346 nucleated epidermal cells per mm2, 1394 Langerhans cells per mm2, 1999 melanocytes per mm2, 16 (SC) layers, 900-microm2 corneocyte surface area, 17,778 corneocytes per mm2, 14-d (SC) turnover time, and 93,124 per mm2 total epidermal cells. Given these empirical data: (1) the number of corneocytes is a mean proportional between the sum of the Langerhans cell + melanocyte populations and the number of epidermal cells, 3393/17,778-17,778/93,124; (2) the ratio of nucleated epidermal cells over corneocytes is phi proportional, 75,346/17,778 approximately phi3; (3) assuming similar 14-d turnover times for the (SC) and Malpighian epidermis, the number of corneocytes results from subtraction of a cellular fraction equal to approximately 2/phi2 x the number of living cells, 75,436 - (2/phi2 x 75,346) approximately 17,778; and (4) if total epidermal turnover time equals (SC) turnover time x the ratio of living/dead cells, then compartmental turnover times are unequal (14 d for (SC) to 45.3 d for nucleated epidermis approximately 1/2phi) and cellular replacement rates are 52.9 corneocytes/69.3 keratinocytes per mm2 per h approximately 2/phi2. These empirically derived equivalences provide logicomathematical support for the presence of functional epidermal units in human skin. Validation of a phi proportional unit architecture in human epidermis will be important for tissue engineering of skin and the design of instruments for skin measurement.

  2. Electronic equipment. New functional units in NIM standard

    International Nuclear Information System (INIS)

    Cheminaud, J.; Grasso, G.; Lacroix, C.; Le Baud, P.; Pichot, G.; Poirot, L.

    During the year 1974 some new modules have been developed: i) a tele-control for delay-time which utilizes a multiplexer-demultiplexer; ii) a fast pulse generator for light-emitting diodes which allows the test of devices using photomultipliers; iii) a plug-in-unit of variable shaper for fast pulses, with reset and zero dead time; iv) an amplifier with a 50MHz band-pass and an adjusting amplification from 0 to 10; v) a pocket generator delivering NIM pulses [fr

  3. Process Improvement to Enhance Quality in a Large Volume Labor and Birth Unit.

    Science.gov (United States)

    Bell, Ashley M; Bohannon, Jessica; Porthouse, Lisa; Thompson, Heather; Vago, Tony

    The goal of the perinatal team at Mercy Hospital St. Louis is to provide a quality patient experience during labor and birth. After the move to a new labor and birth unit in 2013, the team recognized many of the routines and practices needed to be modified based on different demands. The Lean process was used to plan and implement required changes. This technique was chosen because it is based on feedback from clinicians, teamwork, strategizing, and immediate evaluation and implementation of common sense solutions. Through rapid improvement events, presence of leaders in the work environment, and daily huddles, team member engagement and communication were enhanced. The process allowed for team members to offer ideas, test these ideas, and evaluate results, all within a rapid time frame. For 9 months, frontline clinicians met monthly for a weeklong rapid improvement event to create better experiences for childbearing women and those who provide their care, using Lean concepts. At the end of each week, an implementation plan and metrics were developed to help ensure sustainment. The issues that were the focus of these process improvements included on-time initiation of scheduled cases such as induction of labor and cesarean birth, timely and efficient assessment and triage disposition, postanesthesia care and immediate newborn care completed within approximately 2 hours, transfer from the labor unit to the mother baby unit, and emergency transfers to the main operating room and intensive care unit. On-time case initiation for labor induction and cesarean birth improved, length of stay in obstetric triage decreased, postanesthesia recovery care was reorganized to be completed within the expected 2-hour standard time frame, and emergency transfers to the main hospital operating room and intensive care units were standardized and enhanced for efficiency and safety. Participants were pleased with the process improvements and quality outcomes. Working together as a team

  4. "I Always Feel Like I Have to Rush…" Pet Owner and Small Animal Veterinary Surgeons' Reflections on Time during Preventative Healthcare Consultations in the United Kingdom.

    Science.gov (United States)

    Belshaw, Zoe; Robinson, Natalie J; Dean, Rachel S; Brennan, Marnie L

    2018-02-08

    Canine and feline preventative healthcare consultations can be more complex than other consultation types, but they are typically not allocated additional time in the United Kingdom (UK). Impacts of the perceived length of UK preventative healthcare consultations have not previously been described. The aim of this novel study was to provide the first qualitative description of owner and veterinary surgeon reflections on time during preventative healthcare consultations. Semi-structured telephone interviews were conducted with 14 veterinary surgeons and 15 owners about all aspects of canine and feline preventative healthcare consultations. These qualitative data were thematically analysed, and four key themes identified. This paper describes the theme relating to time and consultation length. Patient, owner, veterinary surgeon and practice variables were recalled to impact the actual, versus allocated, length of a preventative healthcare consultation. Preventative healthcare consultations involving young, old and multi-morbid animals and new veterinary surgeon-owner partnerships appear particularly susceptible to time pressures. Owners and veterinary surgeons recalled rushing and minimizing discussions to keep consultations within their allocated time. The impact of the pace, content and duration of a preventative healthcare consultation may be influential factors in consultation satisfaction. These interviews provide an important insight into the complex nature of preventative healthcare consultations and the behaviour of participants under different perceived time pressures. These data may be of interest and relevance to all stakeholders in dog and cat preventative healthcare.

  5. Parametric design studies of toroidal magnetic energy storage units

    International Nuclear Information System (INIS)

    Herring, J.S.

    1990-01-01

    Superconducting magnetic energy storage (SMES) units have a number of advantages as storage devices. Electrical current is the input, output and stored medium, allowing for completely solid-state energy conversion. The magnets themselves have no moving parts. The round-trip efficiency is higher than those for batteries, compressed air or pumped hydro. Output power can be very high, allowing complete discharge of the unit within a few seconds. Finally, the unit can be designed for a very large number of cycles, limited basically by fatigue in the structural components. A small systems code has been written to produce and evaluate self-consistent designs for toroidal superconducting energy storage units. The units can use either low temperature or high temperature superconductors. The coils have 'D' shape where the conductor and its stabilizer/structure is loaded only in tension and the centering forces are borne by a bucking cylinder. The coils are convectively cooled from a cryogenic reservoir in the bore of the coils. The coils are suspended in a cylindrical metal shell which protects the magnet during rail, automotive or shipboard use. It is important to note that the storage unit does not rely on its surroundings for structural support, other than normal gravity and inertial loads. This paper presents designs for toroidal energy storage units produced by the systems code. A wide range of several parameters have been considered, resulting in units storing from 1 MJ to 72 GJ. Maximum fields range from 5 t to 20 T. The masses and volumes of the coils, bucking cylinder, coolant, insulation and outer shell are calculated. For unattended use, the allowable operating time using only the boiloff of the cryogenic fluid for refrigeration is calculated. For larger units, the coils have been divided into modules suitable for normal truck or rail transport. 8 refs., 5 tabs

  6. Parametric design studies of toroidal magnetic energy storage units

    Science.gov (United States)

    Herring, J. Stephen

    Superconducting magnetic energy storage (SMES) units have a number of advantages as storage devices. Electrical current is the input, output and stored medium, allowing for completely solid-state energy conversion. The magnets themselves have no moving parts. The round trip efficiency is higher than those for batteries, compressed air or pumped hydro. Output power can be very high, allowing complete discharge of the unit within a few seconds. Finally, the unit can be designed for a very large number of cycles, limited basically by fatigue in the structural components. A small systems code was written to produce and evaluate self-consistent designs for toroidal superconducting energy storage units. The units can use either low temperature or high temperature superconductors. The coils have D shape where the conductor and its stabilizer/structure is loaded only in tension and the centering forces are borne by a bucking cylinder. The coils are convectively cooled from a cryogenic reservoir in the bore of the coils. The coils are suspended in a cylindrical metal shell which protects the magnet during rail, automotive or shipboard use. It is important to note that the storage unit does not rely on its surroundings for structural support, other than normal gravity and inertial loads. Designs are presented for toroidal energy storage units produced by the systems code. A wide range of several parameters have been considered, resulting in units storing from 1 MJ to 72 GJ. Maximum fields range from 5 T to 20 T. The masses and volumes of the coils, bucking cylinder, coolant, insulation and outer shell are calculated. For unattended use, the allowable operating time using only the boiloff of the cryogenic fluid for refrigeration is calculated. For larger units, the coils were divided into modules suitable for normal truck or rail transport.

  7. Advertising Emergency Department Wait Times

    OpenAIRE

    Weiner, Scott G

    2013-01-01

    Advertising emergency department (ED) wait times has become a common practice in the United States. Proponents of this practice state that it is a powerful marketing strategy that can help steer patients to the ED. Opponents worry about the risk to the public health that arises from a patient with an emergent condition self-triaging to a further hospital, problems with inaccuracy and lack of standard definition of the reported time, and directing lower acuity patients to the higher cost ED se...

  8. Time Limits : Effects on Recall

    OpenAIRE

    Hirano, Kinue

    2000-01-01

    This study investigates the effects of differing time limits and the level of language proficiency on the written recalls of 66 Japanese EFL undergraduates. Results showed that different time limits affected total recall, but not main ideas recalled. Regardless of proficiency level, the 20-minute group (Group 2) recalled a greater number of idea units than the 8-minute group (Group 1). However, no significant difference was found between Groups 1 and 2 regarding the recall of main ideas, alth...

  9. Establishment and assessment of cataract surgery in Day-care Unit at northwest of China

    Directory of Open Access Journals (Sweden)

    Xiu-Li Zhang

    2018-04-01

    Full Text Available AIM: To describe the protocol and economic cost of the Day-care Unit cataract surgery procedure in northwest of China.METHODS: Patients who received phacoemulcification and intraocular lens implantation in both Day-care Unit and regular Unit were recruited from January 2016 to December 2016. The baseline data and average cost were recorded and analyzed. Furthermore, satisfaction questionnaire of patients were collected.RESULTS: Patients with Day-care Unit showed shorter registration duration, less cost including housing and nursing charge as well as higher rate of patient satisfaction. Meanwhile, Day-care Unit shorten the time the doctors and nurses spending on filling the medical charts.CONCLUSION:Day-care Unit cataract surgery procedure could benefit both patients and medical staffs and is worthy to generalize.

  10. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2007-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Unit 2 that will extend the in-service tile of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from he bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  11. Closure Plan for Corrective Action Unit 110: Area 3 RWMS U-3ax/bl Disposal Unit, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Fitzmaurice, T. M.

    2000-01-01

    This Closure Plan has been prepared for the Area 3 RWMS U-3ax/bl Disposal Unit Corrective Action Unit 110 in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection [NDEP] et al., 1996). The U-3ax/bl is a historic disposal unit within the Area 3 Radioactive Waste Management Site located on the Nevada Test Site (NTS). The unit, which was formed by excavating the area between two subsidence craters (U-3ax and U-3bl), was operationally closed in 1987. The U-3ax/bl disposal unit is scheduled for permanent closure under the Resource Conservation and Recovery Act as a hazardous waste landfill. Existing records indicate that, from July 1968 to December 1987, U-3ax/bl received 2.3 x 10 5 cubic meters (8.12 x 10 6 cubic feet) of waste. NTS nuclear device testing generated approximately 95 percent of the total volume disposed of in U-3ax/bl, the majority of which came from the Waste Consolidation Project (80 percent of the total volume) (Elletson and Johnejack, 1995). Area 3 is located in Yucca Flat, within the northeast quadrant of the NTS. The Yucca Flat watershed is a structurally closed basin encompassing an area of approximately 780 square kilometers (300 square miles). The structural geomorphology of Yucca Flat is typical of the Basin and Range Physiographic Province. Yucca Flat lies in one of the most arid regions of the country. Water balance calculations for Area 3 indicate that it is continuously in a state of moisture deficit. The U-3ax/bl Disposal Unit will be closed in place by installing a Resource Conservation and Recovery Act equivalent cover. Following cover construction a fence will be installed around the cover to prevent accidental damage to the cover. Post-closure monitoring will consist of site inspections to determine the condition of the engineered cover and cover performance monitoring using Time-Domain Reflectometry arrays to monitor moisture migration in the cover. Any identified maintenance and repair

  12. Closure Plan for Corrective Action Unit 110: Area 3 RWMS U-3ax/bl Disposal Unit, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    T. M. Fitzmaurice

    2000-08-01

    This Closure Plan has been prepared for the Area 3 RWMS U-3ax/bl Disposal Unit Corrective Action Unit 110 in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection [NDEP] et al., 1996). The U-3ax/bl is a historic disposal unit within the Area 3 Radioactive Waste Management Site located on the Nevada Test Site (NTS). The unit, which was formed by excavating the area between two subsidence craters (U-3ax and U-3bl), was operationally closed in 1987. The U-3ax/bl disposal unit is scheduled for permanent closure under the Resource Conservation and Recovery Act as a hazardous waste landfill. Existing records indicate that, from July 1968 to December 1987, U-3ax/bl received 2.3 x 10{sup 5} cubic meters (8.12 x 10{sup 6} cubic feet) of waste. NTS nuclear device testing generated approximately 95 percent of the total volume disposed of in U-3ax/bl, the majority of which came from the Waste Consolidation Project (80 percent of the total volume) (Elletson and Johnejack, 1995). Area 3 is located in Yucca Flat, within the northeast quadrant of the NTS. The Yucca Flat watershed is a structurally closed basin encompassing an area of approximately 780 square kilometers (300 square miles). The structural geomorphology of Yucca Flat is typical of the Basin and Range Physiographic Province. Yucca Flat lies in one of the most arid regions of the country. Water balance calculations for Area 3 indicate that it is continuously in a state of moisture deficit. The U-3ax/bl Disposal Unit will be closed in place by installing a Resource Conservation and Recovery Act equivalent cover. Following cover construction a fence will be installed around the cover to prevent accidental damage to the cover. Post-closure monitoring will consist of site inspections to determine the condition of the engineered cover and cover performance monitoring using Time-Domain Reflectometry arrays to monitor moisture migration in the cover. Any identified maintenance and

  13. 40 CFR 60.2989 - Does this subpart directly affect incineration unit owners and operators in my State?

    Science.gov (United States)

    2010-07-01

    ... incineration unit owners and operators in my State? 60.2989 Section 60.2989 Protection of Environment... SOURCES Emission Guidelines and Compliance Times for Other Solid Waste Incineration Units That Commenced... incineration unit owners and operators in my State? (a) No, this subpart does not directly affect incineration...

  14. Accounting of costs in a service of physical health. Relative units of value in dosimetry clinic in teletherapy

    International Nuclear Information System (INIS)

    Font Gomez, J. A.; Gandia Martinez, A.; Jimenez Albericio, F. J.; Andres Redondon, M. M.; Mengual Gil, M. A.

    2013-01-01

    A single - although laborious - start in the economic and clinical management of our units can be come to the knowledge of the time invested in the tasks functional, having to differentiate them, name them and even encrypt them. The time spent in performing the tasks multiplied by the annual number of these will indicate the resources necessary to achieve our objectives. In addition, pooling the values of times that members of the Unit provide analysed inter-workers dispersal, their causes and possible solutions. The establishment of relative units of value in any process benefits all workers involved in the process since it allows to know the dispersion of the times that each person employed in the development of the tasks. (Author)

  15. Japanese Immigrants in the United States and Canada : A Comparative Analysis

    OpenAIRE

    Koch, Glenn G.

    2000-01-01

    The experiences of Japanese immigrants to the United States and Canada is the difference between assimilating cultures, which bear different attitudes towards wealth and immigration. The United States population does not openly hate Japanese, but in times of economic problems the inherent discrimination shown towards those perceived as outsiders rises. Canada does not have such constrictions, although this should not be construed as implying that there is no discrimination in Canada. It is si...

  16. A variant of the dynamic programming algorithm for unit commitment of combined heat and power systems

    DEFF Research Database (Denmark)

    Rong, Aiying; Hakonen, Henri; Lahdelma, Risto

    2008-01-01

    introduce in this paper the DP-RSC1 algorithm, which is a variant of the dynamic programming (DP) algorithm based on linear relaxation of the ON/OFF states of the units and sequential commitment of units one by one. The time complexity of DP-RSC1 is proportional to the number of generating units...

  17. Some philosophical problems with the space-time metric and alternative theories of gravitation

    International Nuclear Information System (INIS)

    Bergh, N. van den

    1983-01-01

    Some problems in Synge's chronometric approach and the geodesic method of EHLERS, PIRANI and SCHILD are discussed. We construct a particular type of standard clock which does not suffer from the usual difficulties with atomic clocks and which enables us to analyse the old problem whether atomic time is identical with proper time. We conclude that a non-constant coupling between our Heisenberg units and the geodesic units leads to conflicts with astronomical observations. Therefore the question whether particle masses are varying can only be stated in the Planck unit system. (author)

  18. Changes Coming to the International System of Units

    Science.gov (United States)

    Aubrecht, Gordon J., II

    2012-01-01

    The International System of Units (SI) is a coherent system based originally on measurements of properties of material objects. In more recent times, the adopted definitions depend on setting values of universal constants wherever possible. The last remaining human-made material object on which a standard is based is a platinum-iridium kilogram…

  19. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  20. Designing a Clinical Data Warehouse Architecture to Support Quality Improvement Initiatives.

    Science.gov (United States)

    Chelico, John D; Wilcox, Adam B; Vawdrey, David K; Kuperman, Gilad J

    2016-01-01

    Clinical data warehouses, initially directed towards clinical research or financial analyses, are evolving to support quality improvement efforts, and must now address the quality improvement life cycle. In addition, data that are needed for quality improvement often do not reside in a single database, requiring easier methods to query data across multiple disparate sources. We created a virtual data warehouse at NewYork Presbyterian Hospital that allowed us to bring together data from several source systems throughout the organization. We also created a framework to match the maturity of a data request in the quality improvement life cycle to proper tools needed for each request. As projects progress in the Define, Measure, Analyze, Improve, Control stages of quality improvement, there is a proper matching of resources the data needs at each step. We describe the analysis and design creating a robust model for applying clinical data warehousing to quality improvement.

  1. Cystic fibrosis physicians' perspectives on the timing of referral for lung transplant evaluation: a survey of physicians in the United States.

    Science.gov (United States)

    Ramos, Kathleen J; Somayaji, Ranjani; Lease, Erika D; Goss, Christopher H; Aitken, Moira L

    2017-01-19

    Prior studies reveal that a significant proportion of patients with cystic fibrosis (CF) and advanced lung disease are not referred for lung transplant (LTx) evaluation. We sought to assess expert CF physician perspectives on the timing of LTx referral and investigate their LTx knowledge. We developed an online anonymous survey that was distributed by the Cystic Fibrosis Foundation (CFF) to the medical directors of all CFF-accredited care centers in the United States in 2015. The survey addressed only adult patients (≥18 years old) and was sent to 119 adult CF physicians, 86 CFF-affiliated CF physicians (who see adults and children, but have smaller program sizes than adult or pediatric centers), and 127 pediatric CF physicians (who see some adults, but mostly children). The focus of the questions was on CFF-care center characteristics, physician experience and indications/contraindications to referral for LTx evaluation. There were 114/332 (34%) total responses to the survey. The response rates were: 57/119 (48%) adult physicians, 12/86 (14%) affiliate physicians and 43/127 (34%) pediatric physicians; 2 physicians did not include their CFF center type. Despite the poor ability of FEV 1  < 30% to predict death within 2 years, 94% of responding CF physicians said they would refer an adult patient for LTx evaluation if the patient's lung function fell to FEV 1  < 30% predicted. Only 54% of respondents report that pulmonary hypertension would trigger referral. Pulmonary hypertension is an internationally recommended indication to list a patient for LTx (not just for referral for evaluation). Very few physicians (N = 17, 15%) employed components of the lung allocation score (LAS) to determine the timing of referral for LTx evaluation. Interestingly, patient preference not to undergo LTx was "often" or "always" the primary patient-related reason to defer referral for LTx evaluation for 41% (47/114) of respondents. Some potential barriers to timely LTx

  2. Venusian extended ejecta deposits as time-stratigraphic markers

    Science.gov (United States)

    Izenberg, Noam R.

    1992-01-01

    Use of impact crater ejects at time-stratigraphic markers was established during lunar geologic mapping efforts. The basic premise is that the deposition of impact ejecta, either by itself or mixed with impact-excavated material, is superimposed on a surface. The deposit becomes an observable, mappable unit produced in a single instant in geologic time. Up to two-thirds of Venus craters exhibit extended ejecta deposits. A reconnaissance survey of 336 craters (about 40 percent of the total population) was conducted. About half the craters examined were located in and around the Beta-Atla-Themis region, and half were spread over the western hemisphere of the planet. The survey was conducted using primarily C1-MIDR images. The preliminary survey shows: (1) of the 336 craters, 223 were found to have extended ejecta deposits. This proportion is higher than that found in other Venus crater databases by up to a factor of 2. (2) 53 percent of all extended ejecta craters were unambiguously superimposed on all volcanic and tectonic units. Crater Annia Faustina's associated parabolic ejecta deposit is clearly superimposed on volcanic flows coming from Gula Mons to the west. Parabola material from Faustina has covered the lava flows, smoothing the surface and reducing its specific backscatter cross section. The stratigraphy implies that the parabola material is the youngest observable unit in the region. (3) 12 percent of extended ejecta deposits are superimposed by volcanic materials. Crater Hwangcini has extended ejecta that has been covered by volcanic flows from a dome field to the northwest, implying that the volcanic units were emplaced subsequent to the ejecta deposit and are the youngest units in the locality. (4) It is difficult to determine the stratigraphic relationships of the remaining extended ejecta deposits in SAR at C1-MIDR resolution. Examination of higher resolution images and application of the other Magellan datasets in systematic manner should resolve

  3. Partial wave analysis using graphics processing units

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Niklaus; Liu Beijiang; Wang Jike, E-mail: nberger@ihep.ac.c [Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Lu, Shijingshan, 100049 Beijing (China)

    2010-04-01

    Partial wave analysis is an important tool for determining resonance properties in hadron spectroscopy. For large data samples however, the un-binned likelihood fits employed are computationally very expensive. At the Beijing Spectrometer (BES) III experiment, an increase in statistics compared to earlier experiments of up to two orders of magnitude is expected. In order to allow for a timely analysis of these datasets, additional computing power with short turnover times has to be made available. It turns out that graphics processing units (GPUs) originally developed for 3D computer games have an architecture of massively parallel single instruction multiple data floating point units that is almost ideally suited for the algorithms employed in partial wave analysis. We have implemented a framework for tensor manipulation and partial wave fits called GPUPWA. The user writes a program in pure C++ whilst the GPUPWA classes handle computations on the GPU, memory transfers, caching and other technical details. In conjunction with a recent graphics processor, the framework provides a speed-up of the partial wave fit by more than two orders of magnitude compared to legacy FORTRAN code.

  4. 200-UP-2 Operable Unit technical baseline report

    International Nuclear Information System (INIS)

    Deford, D.H.

    1991-02-01

    This report is prepared in support of the development of a Remedial Investigation/Feasibility Study (RI/FS) Work Plan for the 200-UP-2 Operable Unit by EBASCO Environmental, Incorporated. It provides a technical baseline of the 200-UP-2 Operable Unit and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The 200-UP-2 Operable Unit Technical Baseline Report is based on review and evaluation of numerous Hanford Site current and historical reports, Hanford Site drawings and photographs and is supplemented with Hanford Site inspections and employee interviews. No field investigations or sampling were conducted. Each waste site in the 200-UP-2 Operable Unit is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. The 200-UP-2 Operable Unit consists of liquid-waste disposal sites in the vicinity of, and related to, U Plant operations in the 200 West Area of the Hanford Site. The ''U Plant'' refers to the 221-U Process Canyon Building, a chemical separations facility constructed during World War 2. It also includes the Uranium Oxide (UO 3 ) Plant, which was constructed at the same time and, like the 221-U Process Canyon Building, was later converted for other missions. Waste sites in the 200-UP-2 Operable Unit are associated with the U Plant Uranium Metal Recovery Program mission that occurred between 1952 and 1958 and the UO 3 Plant's ongoing uranium oxide mission and include one or more cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, waste vaults, and the lines and encasements that connect them. 11 refs., 1 tab

  5. Utilisation and outcomes following the introduction of an interventional radiology day unit

    International Nuclear Information System (INIS)

    Makris, G.C.; Shaida, N.; Pyneeandee, R.; Shaw, A.; See, T.C.

    2016-01-01

    Aim: To assess the utilisation of an interventional radiology day unit (RDU), the rates of on-time discharges, the financial performance of the unit, and finally, the patient satisfaction rates. Materials and methods: Data regarding the unit utilisation, discharge times, and complications were retrospectively collected for the first 2 years of operation of the unit (1 April 2013 to 1 January 2015). In addition, monitoring the activity going through the RDU and applying a contribution margin to the freed-up beds measured the financial performance. The data were provided by the finance department of the hospital. Satisfaction survey questionnaires were sent randomly by post to 100 patients who had been previously admitted to the RDU. Results: During the study period, 3019 patients were admitted to the RDU, comprising 1426 during the first year and 1513 during the second. On average, 5.6 patients were discharged from the RDU on every working day during the first year and 7.1 patients during the second (21% increase in the discharge rate). Given the 8-hour working time configuration of the unit, a realistic 80% utilisation rate of the RDU's seven beds could free a total of 1400 inpatient bed days over a full year. The cost of delivering these episodes of care was reduced by approximately 50%. From the financial data, it was estimated that the RDU managed to achieve a total of £393,000 in savings for the Trust for the financial year 2013–2014. The return rate of the patient satisfaction survey was 40%. All patients were satisfied with their overall RDU experience. Conclusion: The RDU has brought significant benefits for patients and the Trust without compromises in safety or quality. - Highlights: • Radiology Day units can improve workflow through improved efficiency. • RDUs can decrease the treatment-related costs mainly by reducing the need for unnecessary overnight hospitalisation. • They appear to be welcome by the patients with excellent feedback so far.

  6. THE EFFICIENCY OF GAS-PUMPING UNITS

    Directory of Open Access Journals (Sweden)

    E. I. Kupreev

    2016-01-01

    Full Text Available . The reliability of the gas transmission network of the JSC “Gazprom Transgaz Belarus” depends on the efficiency of gas compressor units. Pipeline transport takes the first place among all the other ways to deliver gas because it ensures a uniform and uninterrupted supply of gas at minimum costs. The main objects of main gas pipelines include process areas, including several compressor stations and sections of the pipeline between them. Currently, a significant part of the main equipment of the gas industry is approaching its deadline of operation, which causes decrease in energy efficiency and reliability of the transmission system. At compressor plants of the JSC “Gazprom Transgaz Belarus” there are more than 4000 gas compressor units in operation including about 80% ones with gas turbine drives. It is clear that the drives of these units take a significant proportion of the pumped gas. For many years the company invests and actively participates in the creation of modern gas-pumping units practicing the wide use of conversion potential of the CIS countries. In recent years, a comprehensive approach to the assessment of the reliability and efficiency of objects of gas pipelines on the basis of mathematical modeling is actively applied. Together with the development of computer supervisory and control this opens up opportunities to improve energy efficiency in pipeline transport of gas on the basis of mathematical models and processes. The real effect obtaining is based on the actual performance of the equipment that needs to be monitored over time and to clarify.

  7. Orderly recruitment of motor units under optical control in vivo.

    Science.gov (United States)

    Llewellyn, Michael E; Thompson, Kimberly R; Deisseroth, Karl; Delp, Scott L

    2010-10-01

    A drawback of electrical stimulation for muscle control is that large, fatigable motor units are preferentially recruited before smaller motor units by the lowest-intensity electrical cuff stimulation. This phenomenon limits therapeutic applications because it is precisely the opposite of the normal physiological (orderly) recruitment pattern; therefore, a mechanism to achieve orderly recruitment has been a long-sought goal in physiology, medicine and engineering. Here we demonstrate a technology for reliable orderly recruitment in vivo. We find that under optical control with microbial opsins, recruitment of motor units proceeds in the physiological recruitment sequence, as indicated by multiple independent measures of motor unit recruitment including conduction latency, contraction and relaxation times, stimulation threshold and fatigue. As a result, we observed enhanced performance and reduced fatigue in vivo. These findings point to an unanticipated new modality of neural control with broad implications for nervous system and neuromuscular physiology, disease research and therapeutic innovation.

  8. Time on Task in Intensive Modes of Delivery

    Science.gov (United States)

    Kuiper, Alison; Solomonides, Ian; Hardy, Lara

    2015-01-01

    This paper reports on an investigation into how staff teaching in compressed courses can encourage student engagement and enhance student use of learning time, despite significant restraints of time as well as distance. Typically these courses (described here as units) are expected to have comparable learning outcomes to their full-semester…

  9. Comparison between dynamic programming and genetic algorithm for hydro unit economic load dispatch

    Directory of Open Access Journals (Sweden)

    Bin Xu

    2014-10-01

    Full Text Available The hydro unit economic load dispatch (ELD is of great importance in energy conservation and emission reduction. Dynamic programming (DP and genetic algorithm (GA are two representative algorithms for solving ELD problems. The goal of this study was to examine the performance of DP and GA while they were applied to ELD. We established numerical experiments to conduct performance comparisons between DP and GA with two given schemes. The schemes included comparing the CPU time of the algorithms when they had the same solution quality, and comparing the solution quality when they had the same CPU time. The numerical experiments were applied to the Three Gorges Reservoir in China, which is equipped with 26 hydro generation units. We found the relation between the performance of algorithms and the number of units through experiments. Results show that GA is adept at searching for optimal solutions in low-dimensional cases. In some cases, such as with a number of units of less than 10, GA's performance is superior to that of a coarse-grid DP. However, GA loses its superiority in high-dimensional cases. DP is powerful in obtaining stable and high-quality solutions. Its performance can be maintained even while searching over a large solution space. Nevertheless, due to its exhaustive enumerating nature, it costs excess time in low-dimensional cases.

  10. A Simple, Reliable Precision Time Analyser

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, B. V.; Nargundkar, V. R.; Subbarao, K.; Kamath, M. S.; Eligar, S. K. [Atomic Energy Establishment Trombay, Bombay (India)

    1966-06-15

    A 30-channel time analyser is described. The time analyser was designed and built for pulsed neutron research but can be applied to other uses. Most of the logic is performed by means of ferrite memory core and transistor switching circuits. This leads to great versatility, low power consumption, extreme reliability and low cost. The analyser described provides channel Widths from 10 {mu}s to 10 ms; arbitrarily wider channels are easily obtainable. It can handle counting rates up to 2000 counts/min in each channel with less than 1% dead time loss. There is a provision for an initial delay equal to 100 channel widths. An input pulse de-randomizer unit using tunnel diodes ensures exactly equal channel widths. A brief description of the principles involved in core switching circuitry is given. The core-transistor transfer loop is compared with the usual core-diode loops and is shown to be more versatile and better adapted to the making of a time analyser. The circuits derived from the basic loop are described. These include the scale of ten, the frequency dividers and the delay generator. The current drivers developed for driving the cores are described. The crystal-controlled clock which controls the width of the time channels and synchronizes the operation of the various circuits is described. The detector pulse derandomizer unit using tunnel diodes is described. The scheme of the time analyser is then described showing how the various circuits can be integrated together to form a versatile time analyser. (author)

  11. The personal experience of time

    CERN Document Server

    Wessman, Alden

    1977-01-01

    The fundamental nature of human time experience has concerned artists, poets, philosophers, and scientists throughout the ages. Any consideration of human action requires awareness of its temporal aspects. However, simply to view time in the same units and dimensions as the physicist employs in describing events robs personal time of its "lived" quality. The use of physical time concepts in the description of human events is often artificial and misleading. It fails to account for the facts that human time estimates rarely match clock and calendar time; that societies and individuals demonstrate vast differences in their constructions and uses of time; and that temporal perceptions and attitudes change within an individual both during a single day and throughout his life span. The present volume does not view time as something that is sensed in the same way that one would sense or perceive spatial or sensory stimuli. Rather, it views time as a complex set of personally experienced cognitive constructs used by...

  12. Experience in lifetime extension of the first generation WWER-440 power units

    International Nuclear Information System (INIS)

    Medvedev, P.

    2002-01-01

    In connection with the expiration of the lifetime for the first generation WWER-440 reactors in Russian Federation (Novo Voronezh and Kola NPP), the legal procedures and Life Time Extension (LTE) Program are discussed. The LTE Program includes: development of regulation basis; economic efficiency studies; power unit modernization; power unit comprehensive examination and justification od equipment resource; in-dept safety assessment; operational license acquisition. As a result from the LTE Program the safety level of the unit 3 of the Novo Voronezh NPP is significantly increases, the operational period has been justified and a 5-year license has been issued

  13. Time-dependent histamine release from stored human blood products

    DEFF Research Database (Denmark)

    Nielsen, Hans Jørgen; Edvardsen, L; Vangsgaard, K

    1996-01-01

    storage. Whole blood (six units), plasma-reduced whole blood (six units), and plasma- and buffy coat-reduced (saline-adenine-glucose-mannitol) (SAGM) blood (six units) from unpaid healthy donors were stored in the blood bank for 35 days at 4 degrees C. Plasma histamine and total cell-bound histamine......Perioperative transfusion of whole blood has been shown to amplify trauma-induced immunosuppression, which could be attenuated by perioperative administration of histamine2 receptor antagonists. Supernatants from different blood products were, therefore, analysed for histamine content during.......0 (range 176.0-910.0) nmol/l in whole blood and 475.0 (range 360.0-1560.0) nmol/l in plasma-reduced whole blood, while it was undetectable in SAGM blood. Spontaneous histamine release increased in a time-dependent manner from a median of 6.7 (range 2.2-17.4) nmol/l at the time of storage to 175.0 (range 33...

  14. Power-law-lapse time gauges

    International Nuclear Information System (INIS)

    Jantzen, R.T.

    1988-01-01

    The choice of time function for cosmological solutions of gravitational field equations is related to the action of the group of independent scale transformations of the unit of length along orthogonal spatial directions. This is accomplished by the introduction of lapse functions which depend explicitly on the spatial metric in an appropriately defined power-law fashion. The resulting power-law-lapse time gauges are the key to producing nearly all exact solutions of the class of models for which the field equations reduce to ordinary differential equations

  15. Leaching properties of slag generated by a gasification/vitrification unit: the role of pH, particle size, contact time and cooling method used.

    Science.gov (United States)

    Moustakas, K; Mavropoulos, A; Katsou, E; Haralambous, K J; Loizidou, M

    2012-03-15

    The environmental impact from the operation of thermal waste treatment facilities mainly originates from the air emissions, as well as the generated solid residues. The objective of this paper is to examine the slag residue generated by a demonstration plasma gasification/vitrification unit and investigate the composition, the leaching properties of the slag under different conditions, as well as the role of the cooling method used. The influence of pH, particle size and contact time on the leachability of heavy metals are discussed. The main outcome is that the vitrified slag is characterized as inert and stable and can be safely disposed at landfills or used in the construction sector. Finally, the water-cooled slag showed better resistance in relation to heavy metal leachability compared to the air-cooled slag. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Second unit scheduling concerns on a dual-unit nuclear project

    International Nuclear Information System (INIS)

    Block, H.R.; Mazzini, R.A.

    1978-01-01

    This paper explores the planning and scheduling problems of Unit 2 of the Susquehanna steam electric station. The causes of these problems and methods to avoid or mitigate their consequences are discussed. The Susquehanna steam electric station has two boiling water reactors rated at 1,100 MW each. Topics considered include cost factors, structures, equipment, engineering and home office, construction services, completion data phasing, work sequencing, structural dependences, and segregation. Substatial cost and schedule benefits can result if two nuclear units are designed and constructed as one integral station, and if maximum sharing of facilities and services between the units occurs. It is concluded that the cost benefits of highly integrated dual unit construction outweigh the schedule and logistical problems caused by that approach

  17. Technological developments in real-time operational hydrologic forecasting in the United States

    Science.gov (United States)

    Hudlow, Michael D.

    1988-09-01

    The hydrologic forecasting service of the United States spans applications and scales ranging from those associated with the issuance of flood and flash warnings to those pertaining to seasonal water supply forecasts. New technological developments (underway in or planned by the National Weather Service (NWS) in support of the Hydrologic Program) are carried out as combined efforts by NWS headquarters and field personnel in cooperation with other organizations. These developments fall into two categories: hardware and software systems technology, and hydrometeorological analysis and prediction technology. Research, development, and operational implementation in progress in both of these areas are discussed. Cornerstones of an overall NWS modernization effort include implementation of state-of-the-art data acquisition systems (including the Next Generation Weather Radar) and communications and computer processing systems. The NWS Hydrologic Service will capitalize on these systems and will incorporate results from specific hydrologic projects including collection and processing of multivariate data sets, conceptual hydrologic modeling systems, integrated hydrologic modeling systems with meteorological interfaces and automatic updating of model states, and extended streamflow prediction techniques. The salient aspects of ongoing work in these areas are highlighted in this paper, providing some perspective on the future U.S. hydrologic forecasting service and its transitional period into the 1990s.

  18. Data processing system for real-time control

    International Nuclear Information System (INIS)

    Oasa, K.; Mochizuki, O.; Toyokawa, R.; Yahiro, K.

    1983-01-01

    Real-time control, for large Tokamak JT-60, requires various data processings between diagnostic devices to control system. These processings require to high speed performance so that it aims at giving information necessary for feedback control during discharges. Then, the architecture of this system has hierachical structure of processors. These processors are connected each other by the CAMAC modules and the optical communication network, which is the 5 M bytes/second CAMAC serial highway. This system has two kinds of intelligences for this purpose. One is ACM-PU pairs in some torus hall crates which has a microcomputerized auxiliary controller and a preprocessing unit. Other is real-time processor which has a minicomputer and preprocessing unit. Most of the real-time processing, for example Abel inversion are characteristic to the diagnostic devices. Such a processing is carried out by an ACM-PU pair in the crate dedicated to the diagnostic device. Some processings, however, are also necessary which compute secondary parameters as functions of primary parameters. A typical example is Zeff, which is a function of Te, Ne and bremsstrahluny intensity. The real-time processor is equipped for such secondary processings and transfer the results. Preprocessing unit -PU- attached to ACM and real-time processor contains a signal processor, which executes in parallel such function as move, add and multiply during one micro-instruction cycle of 200 nsec. According to the progress of the experiment, more high speed processing are required, so the authors developed the PU-X module that contains multi signal processors. After a shot, inter-shot-processor which consists of general-purpose computers, gathers data into the database, then analyze them, and improve these processes to more effective

  19. Shopping around for hospital services: a comparison of the United States and Canada.

    Science.gov (United States)

    Bell, C M; Crystal, M; Detsky, A S; Redelmeier, D A

    1998-04-01

    Historical comparisons indicate that US hospitals are more expensive than Canadian hospitals, but health care system reform might have changed the relative costs and timeliness of health care in the 2 countries. To estimate the price and convenience of selected hospital services in the United States and Canada for patients in 1997 had they paid out-of-pocket. Cross-sectional telephone survey conducted May 1996 to April 1997. The 2 largest acute care general hospitals from every city in the United States and Canada with a population greater than 500000. Each hospital was telephoned and asked their price and waiting time for 7 services: magnetic resonance imaging of the head without gadolinium; a screening mammogram; a 12-lead electrocardiogram; a prothrombin time measurement; a session of hemodialysis; a screening colonoscopy; and a total knee replacement. Waiting times were measured in days until earliest appointment and charges were converted to American currency. Overall, 48 US and 18 Canadian hospitals were surveyed. Median waiting times were significantly shorter in American hospitals for 4 services, particularly a magnetic resonance imaging of the head (3 days vs 150 days; Preplacement ($26805 vs $10651; Preplacement in the United States. US hospitals still provide higher prices and faster care than Canadian hospitals for patients who pay out-of-pocket.

  20. Making Choices in the Virtual World: The New Model at United Technologies Information Network.

    Science.gov (United States)

    Gulliford, Bradley

    1998-01-01

    Describes changes in services of the United Technologies Corporation Information Network from a traditional library system to a virtual system of World Wide Web sites, a document-delivery unit, telephone and e-mail reference, and desktop technical support to provide remote access. Staff time, security, and licensing issues are addressed.…

  1. NATOs Relevance to United States Enduring National Interests Time to Remove the Training Wheels but Continue to Hold the Handle Bars

    Science.gov (United States)

    2016-06-10

    advice, and friendship will have a lasting and positive effect on not only my military career but also my professional & personal life after the Army...if NATO didn’t exist today, the United States would not seek to create it.”1 Magnus Petersson flrnher asserts that within the United States...this topic relevant to the current and emerging strategic environment.7 Magnus Petersson, The US-NATO Debate: From Libya to Ukraine. (New York

  2. Time-Dependent Statistical Analysis of Wide-Area Time-Synchronized Data

    Directory of Open Access Journals (Sweden)

    A. R. Messina

    2010-01-01

    Full Text Available Characterization of spatial and temporal changes in the dynamic patterns of a nonstationary process is a problem of great theoretical and practical importance. On-line monitoring of large-scale power systems by means of time-synchronized Phasor Measurement Units (PMUs provides the opportunity to analyze and characterize inter-system oscillations. Wide-area measurement sets, however, are often relatively large, and may contain phenomena with differing temporal scales. Extracting from these measurements the relevant dynamics is a difficult problem. As the number of observations of real events continues to increase, statistical techniques are needed to help identify relevant temporal dynamics from noise or random effects in measured data. In this paper, a statistically based, data-driven framework that integrates the use of wavelet-based EOF analysis and a sliding window-based method is proposed to identify and extract, in near-real-time, dynamically independent spatiotemporal patterns from time synchronized data. The method deals with the information in space and time simultaneously, and allows direct tracking and characterization of the nonstationary time-frequency dynamics of oscillatory processes. The efficiency and accuracy of the developed procedures for extracting localized information of power system behavior from time-synchronized phasor measurements of a real event in Mexico is assessed.

  3. Register of basic residential units and spatial units in the Slovak Republic

    International Nuclear Information System (INIS)

    Galdik, S.; Vavrinec, B.

    2005-01-01

    In this contribution authors deal with the register of basic residential units and spatial units in the Slovak Republic. Classification of statistical territorial units is presented. Map data and statistical data contain information about environmental impact of industrial and energetic mills

  4. REDUNDANT ELECTRIC MOTOR DRIVE CONTROL UNIT DESIGN USING AUTOMATA-BASED APPROACH

    Directory of Open Access Journals (Sweden)

    Yuri Yu. Yankin

    2014-11-01

    Full Text Available Implementation of redundant unit for motor drive control based on programmable logic devices is discussed. Continuous redundancy method is used. As compared to segregated standby redundancy and whole system standby redundancy, such method provides preservation of all unit functions in case of redundancy and gives the possibility for continuous monitoring of major and redundant elements. Example of that unit is given. Electric motor drive control channel block diagram contains two control units – the major and redundant; it also contains four power supply units. Control units programming was carried out using automata-based approach. Electric motor drive control channel model was developed; it provides complex simulation of control state-machine and power converter. Through visibility and hierarchy of finite state machines debug time was shortened as compared to traditional programming. Control state-machine description using hardware description language is required for its synthesis with FPGA-devices vendor design software. This description was generated automatically by MATLAB software package. To verify results two prototype control units, two prototype power supply units, and device mock-up were developed and manufactured. Units were installed in the device mock-up. Prototype units were created in accordance with requirements claimed to deliverable hardware. Control channel simulation and tests results in the perfect state and during imitation of major element fault are presented. Automata-based approach made it possible to observe and debug control state-machine transitions during simulation of transient processes, occurring at imitation of faults. Results of this work can be used in development of fault tolerant electric motor drive control channels.

  5. Reserve Component Unit Stability: Effects on Deployability and Training

    Science.gov (United States)

    2010-01-01

    within the last year before mobi - lization). However, attendance rates at AT have historically ranged around 60 to 70 percent, and, the more time they...recruiters, offering enlistment incentives, boosting advertising ) but also for initial training of new nonprior- service recruits. And, since the unit would

  6. Nuclear material control and accounting safeguards in the United States

    International Nuclear Information System (INIS)

    Woltermann, H.A.; Rudy, C.R.; Rakel, D.A.; DeVer, E.A.

    1982-01-01

    Material control and accounting (MC and A) of special nuclear material (SNM) must supplement physical security to protect SNM from unlawful use such as terrorist activities. This article reviews MC and A safeguards of SNM in the United States. The following topics are covered: a brief perspective and history of MC and A safeguards, current MC and A practices, measurement methods for SNM, historical MC and A performance, a description of near-real-time MC and A systems, and conclusions on the status of MC and A in the United States

  7. The effect of tubing dwell time on insulin adsorption during intravenous insulin infusions.

    Science.gov (United States)

    Thompson, Cecilia D; Vital-Carona, Jessica; Faustino, E Vincent S

    2012-10-01

    Insulin adsorbs to plastic tubing, which decreases the concentration of an insulin solution delivered from an intravenous infusion set. Dwelling insulin within tubing before starting the infusion decreases adsorption but delays treatment initiation and wastes time in infusion preparation. The lack of data on dwell time effects results in wide variability in practice. We aim to determine the effect of dwell time on insulin concentration from intravenous infusion tubing. In this in vitro study, we used insulin solutions with concentrations of 0.1 unit/mL, 1 unit/mL, and 10 units/mL. Each solution dwelled in intravenous infusion sets for 0, 15, 30, or 60 min. After the dwell, we measured insulin concentrations from the solution bags and tubing. We repeated each insulin concentration-dwell time combination five times. Comparisons were performed using analyses of variance. For each of the three insulin concentrations, the mean insulin concentrations from the tubing were not significantly different between dwell times. Duration of dwell time did not affect insulin adsorption in polypropylene intravenous infusion sets. We recommend that following a 20-mL flush, insulin infusions can be started without any dwell time. Removal of dwell times may improve clinical practice by minimizing preparation time and will allow faster initiation of insulin infusion therapy.

  8. Explaining Direct Care Resource Use of Nursing Home Residents: Findings from Time Studies in Four States

    Science.gov (United States)

    Arling, Greg; Kane, Robert L; Mueller, Christine; Lewis, Teresa

    2007-01-01

    Objective To explain variation in direct care resource use (RU) of nursing home residents based on the Resource Utilization Groups III (RUG-III) classification system and other resident- and unit-level explanatory variables. Data Sources/Study Setting Primary data were collected on 5,314 nursing home residents in 156 nursing units in 105 facilities from four states (CO, IN, MN, MS) from 1998 to 2004. Study Design Nurses and other direct care staff recorded resident-specific and other time caring for all residents on sampled nursing units. Care time was linked to resident data from the Minimum Data Set assessment instrument. Major variables were: RUG-III group (34-group), other health and functional conditions, licensed and other professional minutes per day, unlicensed minutes per day, and direct care RU (wage-weighted minutes). Resident- and unit-level relationships were examined through hierarchical linear modeling. Data Collection/Extraction Methods Time study data were recorded with hand-held computers, verified for accuracy by project staff at the data collection sites and then merged into resident and unit-level data sets. Principal Findings Resident care time and RU varied between and within nursing units. RUG-III group was related to RU; variables such as length of stay and unit percentage of high acuity residents also were significantly related. Case-mix indices (CMIs) constructed from study data displayed much less variation across RUG-III groups than CMIs from earlier time studies. Conclusions Results from earlier time studies may not be representative of care patterns of Medicaid and private pay residents. New RUG-III CMIs should be developed to better reflect the relative costs of caring for these residents. PMID:17362220

  9. SmartUnit: Empirical Evaluations for Automated Unit Testing of Embedded Software in Industry

    OpenAIRE

    Zhang, Chengyu; Yan, Yichen; Zhou, Hanru; Yao, Yinbo; Wu, Ke; Su, Ting; Miao, Weikai; Pu, Geguang

    2018-01-01

    In this paper, we aim at the automated unit coverage-based testing for embedded software. To achieve the goal, by analyzing the industrial requirements and our previous work on automated unit testing tool CAUT, we rebuild a new tool, SmartUnit, to solve the engineering requirements that take place in our partner companies. SmartUnit is a dynamic symbolic execution implementation, which supports statement, branch, boundary value and MC/DC coverage. SmartUnit has been used to test more than one...

  10. Significantly reducing registration time in IGRT using graphics processing units

    DEFF Research Database (Denmark)

    Noe, Karsten Østergaard; Denis de Senneville, Baudouin; Tanderup, Kari

    2008-01-01

    respiration phases in a free breathing volunteer and 41 anatomical landmark points in each image series. The registration method used is a multi-resolution GPU implementation of the 3D Horn and Schunck algorithm. It is based on the CUDA framework from Nvidia. Results On an Intel Core 2 CPU at 2.4GHz each...... registration took 30 minutes. On an Nvidia Geforce 8800GTX GPU in the same machine this registration took 37 seconds, making the GPU version 48.7 times faster. The nine image series of different respiration phases were registered to the same reference image (full inhale). Accuracy was evaluated on landmark...

  11. The First Prototype for the FastTracker Processing Unit

    CERN Document Server

    Andreani, A; The ATLAS collaboration; Beretta, M; Bogdan, M; Citterio, M; Alberti, F; Giannetti, P; Lanza, A; Magalotti, D; Piendibene, M; Shochet, M; Stabile, A; Tang, J; Tompkins, L

    2012-01-01

    Modern experiments search for extremely rare processes hidden in much larger background levels. As the experiment complexity and the accelerator backgrounds and luminosity increase we need increasingly complex and exclusive selections. We present the first prototype of a new Processing Unit, the core of the FastTracker processor for Atlas, whose computing power is such that a couple of hundreds of them will be able to reconstruct all the tracks with transverse momentum above 1 GeV in the ATLAS events up to Phase II instantaneous luminosities (5×1034 cm-2 s-1) with an event input rate of 100 kHz and a latency below hundreds of microseconds. We plan extremely powerful, very compact and low consumption units for the far future, essential to increase efficiency and purity of the Level 2 selected samples through the intensive use of tracking. This strategy requires massive computing power to minimize the online execution time of complex tracking algorithms. The time consuming pattern recognition problem, generall...

  12. Foreign direct investment in the United States and u.s. Interests.

    Science.gov (United States)

    Graham, E M

    1991-12-20

    Foreign direct investment entered the United States at unprecedented rates during the second half of the 1980s. The result has been much higher levels of foreign ownership of U.S. economic activities than those to which the nation has been accustomed. The reasons for this investment include loss of competitiveness of U.S. firms compared to international rivals as well as attractions to foreign investors of the United States itself. The economic effects of greater levels of foreign ownership are generally positive, although some problems with levels of competition could ensue. National security considerations might cause the United States to place some restrictions on this investment, but other restrictions at the present time appear to be unwarranted.

  13. Noise level in intensive care units of a public university hospital in Santa Marta (Colombia).

    Science.gov (United States)

    Garrido Galindo, A P; Camargo Caicedo, Y; Vélez-Pereira, A M

    2016-10-01

    To evaluate the noise level in adult, pediatric and neonatal intensive care units of a university hospital in the city of Santa Marta (Colombia). A descriptive, observational, non-interventional study with follow-up over time was carried out. Continuous sampling was conducted for 20 days for each unit using a type i sound level meter, filter frequency in A weighting and Fast mode. We recorded the maximum values, the 90th percentile as background noise, and the continuous noise level. The mean hourly levels in the adult unit varied between 57.40±1.14-63.47±2.13dBA, with a maximum between 71.55±2.32-77.22±1.94dBA, and a background noise between 53.51±1.16-60.26±2.10dBA; in the pediatric unit the mean hourly levels varied between 57.07±3.07-65.72±2.46dBA, with a maximum of 68.69±3.57-79.06±2.34dBA, and a background noise between 53.33±3.54-61.96±2.85dBA; the neonatal unit in turn presented mean hourly values between 59.54±2.41-65.33±1.77dBA, with a maximum value between 67.20±2.13-77.65±3.74dBA, and a background noise between 55.02±2.03-58.70±1.95dBA. Analysis of variance revealed a significant difference between the hourly values and between the different units, with the time of day exhibiting a greater influence. The type of unit affects the noise levels in intensive care units, the pediatric unit showing the highest values and the adult unit the lowest values. However, the parameter exerting the greatest influence upon noise level is the time of day, with higher levels in the morning and evening, and lower levels at night and in the early morning. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  14. A maintenance policy for two-unit parallel systems based on imperfect monitoring information

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Anne [Department Genie des Systems Industiels (GSI), Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes, Cedex (France)]. E-mail: anne.barros@utt.fr; Berenguer, Christophe [Department Genie des Systems Industiels (GSI), Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes, Cedex (France); Grall, Antoine [Department Genie des Systems Industiels (GSI), Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes, Cedex (France)

    2006-02-01

    In this paper a maintenance policy is optimised for a two-unit system with a parallel structure and stochastic dependences. Monitoring problems are taken into account in the optimisation scheme: the failure time of each unit can be not detected with a given probability. Conditions on the system parameters (unit failure rates) and on the non-detection probabilities must be verified to make the optimisation scheme valid. These conditions are clearly identified. Numerical experiments allow to show the relevance of taking into account monitoring problems in the maintenance model.

  15. A maintenance policy for two-unit parallel systems based on imperfect monitoring information

    International Nuclear Information System (INIS)

    Barros, Anne; Berenguer, Christophe; Grall, Antoine

    2006-01-01

    In this paper a maintenance policy is optimised for a two-unit system with a parallel structure and stochastic dependences. Monitoring problems are taken into account in the optimisation scheme: the failure time of each unit can be not detected with a given probability. Conditions on the system parameters (unit failure rates) and on the non-detection probabilities must be verified to make the optimisation scheme valid. These conditions are clearly identified. Numerical experiments allow to show the relevance of taking into account monitoring problems in the maintenance model

  16. Development of a handy-type laser surgical unit

    Science.gov (United States)

    Abe, Yusuke; Wakamatsu, Koh; Goto, Shigeru

    2005-07-01

    We proposed a concept of a handy-type laser surgical unit for use in outpatient, in ward and in open-air field. To investigate the possibility of the concept, a handy-type semiconductor laser surgical unit was developed experimentally using 2-watts power laser diode with no built-in electrical cooling unit (Peltier chip) and a small rechargeable battery. The drive circuit was constructed with only current limit and ACC circuits. The laser diode was cooled with heat sink and simple fan. Laser irradiation was set to stop at 30 degree Celsius by monitoring the temperature of laser diode with thermistor temperature sensor. With this system, 1.18 watts of laser power at the end of optical fiber with both 600 and 900mm core diameter, and about 30 minutes of continuous irradiating time with Ni-Cd battery (4.8V 1,500mA/h) could be obtained with no over heating in laser diode. The result showed that the high power semiconductor laser could be driven with small battery when specially designed. In an animal experiment, small bleeding could be managed with contact irradiation method. This kind of simple laser surgical unit is considered to be useful for the management of small bleedings in clinical.

  17. Radiation damage and life-time evaluation of RBMK graphite stack

    Energy Technology Data Exchange (ETDEWEB)

    Platonov, P A; Chugunov, O K; Manevsky, V N; Karpukhin, V I [Russian Research Centre Kurchatov Inst., Moscow (Russian Federation). Reactor Material Div.

    1996-08-01

    At the present time there are 11 NPP units with RBMK reactors in operation in Russia, with the oldest now in operation 22 years. Design life-time of the RBMK-1000 reactor is 30 years. This paper addresses the evaluation of RBMK graphite stack life-time. It is the practice in Russia to evaluate the reliability of the channel reactor graphite stack using at least three criteria: degradation of physical-mechanical properties of graphite, preservation of the graphite brick integrity, and degradation of the graphite stack as a structure. Stack life-time evaluation by different criteria indicates that the most realistic approach may be realized on the basis of the criteria of brick cracking and degradation of the graphite stack as a structure. The RBMK reactor graphite stack life-time depends on its temperature and for different units it may be different. (author). 2 refs, 10 figs.

  18. THE DEVELOPMENT OF SPECIAL SEQUENTIALLY-TIMED

    Directory of Open Access Journals (Sweden)

    Stanislav LICHOROBIEC

    2016-06-01

    Full Text Available This article documents the development of the noninvasive use of explosives during the destruction of ice mass in river flows. The system of special sequentially-timed charges utilizes the increase in efficiency of cutting charges by covering them with bags filled with water, while simultaneously increasing the effect of the entire system of timed charges. Timing, spatial combinations during placement, and the linking of these charges results in the loosening of ice barriers on a frozen waterway, while at the same time regulating the size of the ice fragments. The developed charges will increase the operability and safety of IRS units.

  19. Adaptive real-time methodology for optimizing energy-efficient computing

    Science.gov (United States)

    Hsu, Chung-Hsing [Los Alamos, NM; Feng, Wu-Chun [Blacksburg, VA

    2011-06-28

    Dynamic voltage and frequency scaling (DVFS) is an effective way to reduce energy and power consumption in microprocessor units. Current implementations of DVFS suffer from inaccurate modeling of power requirements and usage, and from inaccurate characterization of the relationships between the applicable variables. A system and method is proposed that adjusts CPU frequency and voltage based on run-time calculations of the workload processing time, as well as a calculation of performance sensitivity with respect to CPU frequency. The system and method are processor independent, and can be applied to either an entire system as a unit, or individually to each process running on a system.

  20. 40 CFR 60.4141 - Timing requirements for Hg allowance allocations.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Timing requirements for Hg allowance... Times for Coal-Fired Electric Steam Generating Units Hg Allowance Allocations § 60.4141 Timing requirements for Hg allowance allocations. (a) By November 17, 2006, the permitting authority will submit to...