WorldWideScience

Sample records for newly proposed pool

  1. Security cost allocation under combined bilateral-pool market dispatch

    International Nuclear Information System (INIS)

    Abdullah, M.P.; Hassan, M.Y.; Hussin, F.

    2008-01-01

    Most electricity markets around the world are a combination of bilateral and pool markets, such as NordPool and NYPOOL. In these models, market participants bid into the pool and also make bilateral contracts with each other. This paper addressed the issue of congestion management and security cost allocation in a power pool market model. The basic idea of security cost allocation is to divide the incurred security cost due to congestion relief into pool and bilateral market based on their flow contribution to the congested line. A newly proposed security cost allocation strategy of the combined bilateral-pool market was also presented along with case studies using IEEE-14 bus system that tested the proposed method. Using the proposed method, it was shown that security costs are allocated to market participants at different prices which reflect the load contribution to the security problem. This solves the problem of the uniform security cost allocation in a pure pool market system having uniform pricing, and provides a proper security signal to market participants. 11 refs., 3 tabs., 4 figs

  2. 76 FR 45551 - Post-2014 Resource Pool; Loveland Area Projects, Proposed Power Allocation

    Science.gov (United States)

    2011-07-29

    ... Proposed Power Allocation. SUMMARY: Western Area Power Administration (Western), a Federal power marketing... Pool Proposed Power Allocation developed under the requirements of the Power Marketing Initiative of... resulted in this Notice of Proposed Power Allocation. DATES: The comment period on this Notice of Proposed...

  3. Automation of water supply and recirculation-filtration of water at a swimming pool using Zelio PLC

    Science.gov (United States)

    Diniş, C. M.; Popa, G. N.; Iagăr, A.

    2018-01-01

    The paper proposes the use of the Zelio PLC for the automation of the water supply and recirculation-filtration system of a swimming pool. To do this, the Zelio SR3B261BD - 24V DC with 10 digital inputs (24V DC) and 10 digital outputs (relay contacts) was used. The proposed application makes the control of the water supply pumps and the water recirculation-filtration from a swimming pool. The recirculation-filtration systems for pools and swimming pools are designed to ensure water cleaning and recirculation to achieve optimum quality and lasting service life. The water filtration process is one of the important steps in water treatment in polls and swimming pools. It consists in recirculation of the entire volume of water and begins by absorbing the water in the pool by means of a pump followed by the passing of water through the filter, disinfectant and pH dosing, and reintroducing the water back into the pool or swimming pool through the discharge holes. Filters must to work 24 hours a day to remove pollutants from pools or swimming pools users. Filtration removes suspension particles with different origins. All newly built pools and swimming pools must be fitted with water recirculation systems, and existing ones will be equipped with water recirculation and water treatment systems.

  4. 77 FR 37959 - Financial Management Service; Proposed Collection of Information: Pools and Associations-Annual...

    Science.gov (United States)

    2012-06-25

    ... DEPARTMENT OF THE TREASURY Fiscal Service Financial Management Service; Proposed Collection of Information: Pools and Associations--Annual Letter AGENCY: Financial Management Service, Fiscal Service, Treasury. ACTION: Notice and request for comments. SUMMARY: The Financial Management Service, as part of...

  5. Development of system design and seismic performance evaluation for reactor pool working platform of a research reactor

    International Nuclear Information System (INIS)

    Kwag, Shinyoung; Lee, Jong-Min; Oh, Jinho; Ryu, Jeong-Soo

    2014-01-01

    Highlights: • Design of reactor pool working platform (RPWP) is newly proposed for an open-tank-in-pool type research reactor. • Main concept of RPWP is to minimize the pool top radiation level. • Framework for seismic performance evaluation of nuclear SSCs in a deterministic and a probabilistic manner is proposed. • Structural integrity, serviceability, and seismic margin of the RPWP are evaluated during and after seismic events. -- Abstract: The reactor pool working platform (RPWP) has been newly designed for an open-tank-in-pool type research reactor, and its seismic response, structural integrity, serviceability, and seismic margin have been evaluated during and after seismic events in this paper. The main important concept of the RPWP is to minimize the pool top radiation level by physically covering the reactor pool of the open-tank-in-pool type research reactor and suppressing the rise of flow induced by the primary cooling system. It is also to provide easy handling of the irradiated objects under the pool water by providing guide tubes and refueling cover to make the radioisotopes irradiated and protect the reactor structure assembly. For this concept, the new three dimensional design model of the RPWP is established for manufacturing, installation and operation, and the analytical model is developed to analyze the seismic performance. Since it is submerged under and influenced by water, the hydrodynamic effect is taken into account by using the hydrodynamic added mass method. To investigate the dynamic characteristics of the RPWP, a modal analysis of the developed analytical model is performed. To evaluate the structural integrity and serviceability of the RPWP, the response spectrum analysis and response time history analysis have been performed under the static load and the seismic load of a safe shutdown earthquake (SSE). Their stresses are analyzed for the structural integrity. The possibility of an impact between the RPWP and the most

  6. Numerical modeling of sodium fire – Part II: Pool combustion and combined spray and pool combustion

    International Nuclear Information System (INIS)

    Sathiah, Pratap; Roelofs, Ferry

    2014-01-01

    Highlights: • A CFD based method is proposed for the simulation of sodium pool combustion. • A sodium evaporation based model is proposed to model sodium pool evaporation. • The proposed method is validated against sodium pool experiments of Newman and Payne. • The results obtained using the proposed method are in good agreement with the experiments. - Abstract: The risk of sodium-air reaction has received considerable attention after the sodium-fire accident in Monju reactor. The fires resulting from the sodium-air reaction can be detrimental to the safety of a sodium fast reactor. Therefore, predicting the consequences of a sodium fire is important from a safety point of view. A computational method based on CFD is proposed here to simulate sodium pool fire and understand its characteristics. The method solves the Favre-averaged Navier-Stokes equation and uses a non-premixed mixture fraction based combustion model. The mass transfer of sodium vapor from the pool surface to the flame is obtained using a sodium evaporation model. The proposed method is then validated against well-known sodium pool experiments of Newman and Payne. The flame temperature and location predicted by the model are in good agreement with experiments. Furthermore, the trends of the mean burning rate with initial pool temperature and oxygen concentration are captured well. Additionally, parametric studies have been performed to understand the effects of pool diameter and initial air temperature on the mean burning rate. Furthermore, the sodium spray and sodium pool combustion models are combined to simulate simultaneous spray and pool combustion. Simulations were performed to demonstrate that the combined code could be applied to simulate this. Once sufficiently validated, the present code can be used for safety evaluation of a sodium fast reactor

  7. Numerical modeling of sodium fire – Part II: Pool combustion and combined spray and pool combustion

    Energy Technology Data Exchange (ETDEWEB)

    Sathiah, Pratap, E-mail: pratap.sathiah78@gmail.com [Shell Global Solutions Ltd., Brabazon House, Concord Business Park, Threapwood Road, Manchester M220RR (United Kingdom); Roelofs, Ferry, E-mail: roelofs@nrg.eu [Nuclear Research and Consultancy Group (NRG), Westerduinweg 3, 1755ZG Petten (Netherlands)

    2014-10-15

    Highlights: • A CFD based method is proposed for the simulation of sodium pool combustion. • A sodium evaporation based model is proposed to model sodium pool evaporation. • The proposed method is validated against sodium pool experiments of Newman and Payne. • The results obtained using the proposed method are in good agreement with the experiments. - Abstract: The risk of sodium-air reaction has received considerable attention after the sodium-fire accident in Monju reactor. The fires resulting from the sodium-air reaction can be detrimental to the safety of a sodium fast reactor. Therefore, predicting the consequences of a sodium fire is important from a safety point of view. A computational method based on CFD is proposed here to simulate sodium pool fire and understand its characteristics. The method solves the Favre-averaged Navier-Stokes equation and uses a non-premixed mixture fraction based combustion model. The mass transfer of sodium vapor from the pool surface to the flame is obtained using a sodium evaporation model. The proposed method is then validated against well-known sodium pool experiments of Newman and Payne. The flame temperature and location predicted by the model are in good agreement with experiments. Furthermore, the trends of the mean burning rate with initial pool temperature and oxygen concentration are captured well. Additionally, parametric studies have been performed to understand the effects of pool diameter and initial air temperature on the mean burning rate. Furthermore, the sodium spray and sodium pool combustion models are combined to simulate simultaneous spray and pool combustion. Simulations were performed to demonstrate that the combined code could be applied to simulate this. Once sufficiently validated, the present code can be used for safety evaluation of a sodium fast reactor.

  8. Reactor TRIGA PUSPATI (RTP) spent fuel pool conceptual design

    International Nuclear Information System (INIS)

    Mohd Fazli Zakaria; Tonny Lanyau; Ahmad Nabil Ab Rahim

    2010-01-01

    Reactor TRIGA PUSPATI (RTP) is the one and only research reactor in Malaysia that has been safely operated and maintained since 1982. In order to enhance technical capabilities and competencies especially in nuclear reactor engineering a feasibility study on RTP power upgrading was proposed to serve future needs for advance nuclear science and technology in the country with the capability of designing and develop reactor system. The need of a Spent Fuel Pool begins with the discharge of spent fuel elements from RTP for temporary storage that includes all activities related to the storage of fuel until it is either sent for reprocessed or sent for final disposal. To support RTP power upgrading there will be major RTP systems replacement such as reactor components and a new temporary storage pool for fuel elements. The spent fuel pool is needed for temporarily store the irradiated fuel elements to accommodate a new reactor core structure. Spent fuel management has always been one of the most important stages in the nuclear fuel cycle and considered among the most common problems to all countries with nuclear reactors. The output of this paper will provide sufficient information to show the Spent Fuel Pool can be design and build with the adequate and reasonable safety assurance to support newly upgraded TRIGA PUSPATI TRIGA Research Reactor. (author)

  9. Fully Automated Lipid Pool Detection Using Near Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Elżbieta Pociask

    2016-01-01

    Full Text Available Background. Detecting and identifying vulnerable plaque, which is prone to rupture, is still a challenge for cardiologist. Such lipid core-containing plaque is still not identifiable by everyday angiography, thus triggering the need to develop a new tool where NIRS-IVUS can visualize plaque characterization in terms of its chemical and morphologic characteristic. The new tool can lead to the development of new methods of interpreting the newly obtained data. In this study, the algorithm to fully automated lipid pool detection on NIRS images is proposed. Method. Designed algorithm is divided into four stages: preprocessing (image enhancement, segmentation of artifacts, detection of lipid areas, and calculation of Lipid Core Burden Index. Results. A total of 31 NIRS chemograms were analyzed by two methods. The metrics, total LCBI, maximal LCBI in 4 mm blocks, and maximal LCBI in 2 mm blocks, were calculated to compare presented algorithm with commercial available system. Both intraclass correlation (ICC and Bland-Altman plots showed good agreement and correlation between used methods. Conclusions. Proposed algorithm is fully automated lipid pool detection on near infrared spectroscopy images. It is a tool developed for offline data analysis, which could be easily augmented for newer functions and projects.

  10. 13 CFR 120.1705 - Pool formation requirements.

    Science.gov (United States)

    2010-01-01

    ... requirements. SBA may adjust the Pool characteristics periodically based on program experience and market... a Pool involving a Pool Loan it does not own, it must purchase the Loan Interest it proposes to pool... purchase the Loan Interest and take it into inventory or settle the purchase of the Loan Interest through...

  11. Generalizing Pooling Functions in CNNs: Mixed, Gated, and Tree.

    Science.gov (United States)

    Lee, Chen-Yu; Gallagher, Patrick; Tu, Zhuowen

    2018-04-01

    In this paper, we seek to improve deep neural networks by generalizing the pooling operations that play a central role in the current architectures. We pursue a careful exploration of approaches to allow pooling to learn and to adapt to complex and variable patterns. The two primary directions lie in: (1) learning a pooling function via (two strategies of) combining of max and average pooling, and (2) learning a pooling function in the form of a tree-structured fusion of pooling filters that are themselves learned. In our experiments every generalized pooling operation we explore improves performance when used in place of average or max pooling. We experimentally demonstrate that the proposed pooling operations provide a boost in invariance properties relative to conventional pooling and set the state of the art on several widely adopted benchmark datasets. These benefits come with only a light increase in computational overhead during training (ranging from additional 5 to 15 percent in time complexity) and a very modest increase in the number of model parameters (e.g., additional 1, 9, and 27 parameters for mixed, gated, and 2-level tree pooling operators, respectively). To gain more insights about our proposed pooling methods, we also visualize the learned pooling masks and the embeddings of the internal feature responses for different pooling operations. Our proposed pooling operations are easy to implement and can be applied within various deep neural network architectures.

  12. Collaborative Car Pooling System

    OpenAIRE

    João Ferreira; Paulo Trigo; Porfírio Filipe

    2009-01-01

    This paper describes the architecture for a collaborative Car Pooling System based on a credits mechanism to motivate the cooperation among users. Users can spend the accumulated credits on parking facilities. For this, we propose a business model to support the collaboration between a car pooling system and parking facilities. The Portuguese Lisbon-s Metropolitan area is used as application scenario.

  13. Transformation of organic N newly added to red soil treated with different cultural practices

    Institute of Scientific and Technical Information of China (English)

    ZhangQin-Zheng; YeQing-Fu; 等

    1998-01-01

    By using 15N tracer method,transformation of organic N,which wqas newly added to red soil treated with different cultural practices,was studied under thelaboratory incubation condition.The experimental results showed that the transformation of N from newly added organic matter and soil native pool during incubation was influenced by cultural practice treatment beforeincubation.Fallow was favorable to the mineralization of newly added organic N and soil N compared with the planting wheat treatment.Planting wheat greatly increased the loss of soil N.Application of fertilizers stimulated the mineralization of newly added organic N and application of organic matter reduced the mineralization,but stimulated microbialtransformation of newly adde4d organic N.

  14. Detection of fission products release in the research reactor 'RA' spent fuel storage pool

    International Nuclear Information System (INIS)

    Matausek, M.V.; Vukadin, Z.; Pavlovic, S.; Maksin, T.; Idakovic, Z.; Marinkovic, N.

    1997-05-01

    Spent fuel resulting from 25 years of operating the 6.5/10 MW thermal heavy water moderated and cooled research reactor RA at the VINCA Institute is presently all stored in the temporary spent fuel storage pool in the basement of the reactor building. In 1984, the reactor was shut down for refurbishment, which for a number of reasons has not yet been completed. Recent investigations show that independent of the future status of the research reactor, safe disposal of the so far irradiated fuel must be the subject of primary concern. The present status of the research reactor RA spent fuel storage pool at the VINCA Institute presents a serious safety problem. Action is therefore initiated in two directions. First, safety of the existing spent fuel storage should be improved. Second, transferring spent fuel into another, presumably dry storage space should be considered. By storing the previously irradiated fuel of the research reactor RA in a newly built storage space, sufficient free space will be provided in the existing spent fuel storage pool for the newly irradiated fuel when the reactor starts operation again. In the case that it would be decided to decommission the research reactor RA, the newly built storage space would provide safe disposal for the fuel irradiated so far

  15. Distributed Technologies in a Data Pool

    Science.gov (United States)

    Keiser, K.; Conover, H.; Graves, S.; He, Y.; Regner, K.; Smith, M.

    2004-12-01

    A Data Pool is an on-line repository providing interactive and programmatic access to data products through a variety of services. The University of Alabama in Huntsville has developed and deployed such a Data Pool in conjunction with the DISCOVER project, a collaboration with NASA and Remote Sensing Systems. DISCOVER provides long-term ocean and climate data from a variety of passive microwave satellite instruments, including such products as sea-surface temperature and wind, air temperature, atmospheric water vapor, cloud water and rain rate. The Data Pool provides multiple methods to access and visualize these products, including conventional HTTP and FTP access, as well as data services that provide for enhanced usability and interoperability, such as GridFTP, OPeNDAP, OpenGIS-compliant web mapping and coverage services, and custom subsetting and packaging services. This paper will focus on the distributed service technologies used in the Data Pool, which spans heterogeneous machines at multiple locations. For example, in order to provide seamless access to data at multiple sites, the Data Pool provides catalog services for all data products at the various data server locations. Under development is an automated metadata generation tool that crawls the online data repositories regularly to dynamically update the Data Pool catalog with information about newly generated data files. For efficient handling of data orders across distributed repositories, the Data Pool also implements distributed data processing services on the file servers where the data resides. Ontologies are planned to support automated service chaining for custom user requests. The UAH Data Pool is based on a configurable technology framework that integrates distributed data services with a web interface and a set of centralized database services for catalogs and order tracking. While this instantiation of the Data Pool was implemented to meet the needs of the DISCOVER project, the framework was

  16. Review of the England and Wales trading arrangements: The proposal to cure the ills by euthanasia of the pool

    International Nuclear Information System (INIS)

    Neushloss, J.; Woolf, F.

    1999-01-01

    Rather than the extreme remedy that has been proposed, some fairly simple changes might go a long way toward reducing the possibilities of gaming, exercise of market power, and the problems associated with the interplay between gas and electricity markets. This article briefly describes the Pool and OFGEM's proposals. The authors then examine OFGEM's assertion that the suggested new trading arrangements will lead to better results and ask whether these arrangements are the only way to achieve the desired outcomes

  17. Compact fuel storage rack for fuel pools

    International Nuclear Information System (INIS)

    Parras, F.; Louvat, J.P.

    1986-01-01

    ETS LEMER and FRAMATOME propose a new compact storage rack. This rack permits a considerable increase of the storage capacity of cooling pools. A short description of the structure and the components is presented, to propose racks that are: . Inalterable, . Compact, . Insensitive to earthquakes. Installation in pools already in operation is simplified by their light structure and the bearing device [fr

  18. Review of the England and Wales trading arrangements: The proposal to cure the ills by euthanasia of the pool

    Energy Technology Data Exchange (ETDEWEB)

    Neushloss, J.; Woolf, F.

    1999-12-01

    Rather than the extreme remedy that has been proposed, some fairly simple changes might go a long way toward reducing the possibilities of gaming, exercise of market power, and the problems associated with the interplay between gas and electricity markets. This article briefly describes the Pool and OFGEM's proposals. The authors then examine OFGEM's assertion that the suggested new trading arrangements will lead to better results and ask whether these arrangements are the only way to achieve the desired outcomes.

  19. Crowd density estimation based on convolutional neural networks with mixed pooling

    Science.gov (United States)

    Zhang, Li; Zheng, Hong; Zhang, Ying; Zhang, Dongming

    2017-09-01

    Crowd density estimation is an important topic in the fields of machine learning and video surveillance. Existing methods do not provide satisfactory classification accuracy; moreover, they have difficulty in adapting to complex scenes. Therefore, we propose a method based on convolutional neural networks (CNNs). The proposed method improves performance of crowd density estimation in two key ways. First, we propose a feature pooling method named mixed pooling to regularize the CNNs. It replaces deterministic pooling operations with a parameter that, by studying the algorithm, could combine the conventional max pooling with average pooling methods. Second, we present a classification strategy, in which an image is divided into two cells and respectively categorized. The proposed approach was evaluated on three datasets: two ground truth image sequences and the University of California, San Diego, anomaly detection dataset. The results demonstrate that the proposed approach performs more effectively and easily than other methods.

  20. A Double Evolutionary Pool Memetic Algorithm for Examination Timetabling Problems

    Directory of Open Access Journals (Sweden)

    Yu Lei

    2014-01-01

    Full Text Available A double evolutionary pool memetic algorithm is proposed to solve the examination timetabling problem. To improve the performance of the proposed algorithm, two evolutionary pools, that is, the main evolutionary pool and the secondary evolutionary pool, are employed. The genetic operators have been specially designed to fit the examination timetabling problem. A simplified version of the simulated annealing strategy is designed to speed the convergence of the algorithm. A clonal mechanism is introduced to preserve population diversity. Extensive experiments carried out on 12 benchmark examination timetabling instances show that the proposed algorithm is able to produce promising results for the uncapacitated examination timetabling problem.

  1. Model of large pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Fay, J.A. [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)]. E-mail: jfay@mit.edu

    2006-08-21

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables.

  2. Model of large pool fires

    International Nuclear Information System (INIS)

    Fay, J.A.

    2006-01-01

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables

  3. Big city consultants shut down our pool : a shocking community pool gets checked for stray voltage

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, P. [Power Line Systems Engineering Inc., Markham, ON (Canada)

    2009-12-15

    This article discussed an investigation conducted at a community pool where swimmers complained of receiving electrical shocks both in the pool and on the pool's deck area. Electrical measurements taken at the pool revealed current flows from the pool water to various points around the deck area. Measured current flow in the pool area was 30 amps even when the main pool service breaker was opened to shut off power to the entire facility. Thirty amps of primary neutral current was then measured on the primary side aerial neutral in front of the pool. A 10 amp primary feeder from the pool joined up with the complex's primary neutral wire to increase the neutral current to 40 amps. The combined 40 amps current then returned to the secondary side of a nearby utility transformer substation. The study showed that the underground wet low-resistance grounded surface area of the pool was attracting the 30 amps of utility current from the surrounding ground area. The local utility disconnected the primary and secondary neutral interconnection at the pool's main 600-volt step-down transformer. The pool deck was removed in order to install additional copper bonding grounds. In order to avert serious injuries, many experts propose that all electric utilities should be required by law to reconfigure their power systems to prevent primary power neutral currents from entering private buildings. 1 tab., 2 figs.

  4. Determination of isotopomers in pools of molecules with polyisotopic elements

    International Nuclear Information System (INIS)

    Zyakun, A.M.; Brenninkmeijer, C.A.M.

    2002-01-01

    Polyisotopic element atoms that are present in a molecule form a pool of isotopomer molecules. Mono- and polyisotopomers are distinguished depending on the quantity of atoms of polyisotopic elements. Methodical approaches have been considered for the quantitative determination of the isotope composition of an element included in mono- and polyisotopic molecules. A possibility of the equally probable (homogeneous) and non-equally probable (non-homogeneous) distribution of isotopes of a polyisotopic element, the atoms of which have different positions in the molecule of polyisotopomer, has been shown. Factors disturbing the homogeneous distribution of isotopes of the element in the polyisotopomer pool have been revealed. When a polyisotopomer is involved in a mass-dependent process or reaction, the homogeneity of isotope distribution of the element is disturbed both in the residual and newly formed pools of polyisotopomer. By the example of CO 2 (polyisotopomer by oxygen) it has been shown that one can judge of the history of the analyzed pool formation by distribution of oxygen isotopes within this pool. The isotope content in the oxygen sites of polyisotopomer is a diagnostic feature of CO 2 involvement in the efflux from a reservoir or influx to the analyzed reservoir from an external source. (author)

  5. Presence and select determinants of organophosphate flame retardants in public swimming pools

    International Nuclear Information System (INIS)

    Teo, Tiffany L.L.; Coleman, Heather M.; Khan, Stuart J.

    2016-01-01

    The occurrence of five organophosphate flame retardants (PFRs) consisting of tributyl phosphate (TNBP), tris(2-chloroethyl) phosphate (TCEP), tris(1-chloro-2-propyl) phosphate (TCIPP), tris(1.3-dichloro-2-propyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) in swimming pools were investigated. Fifteen chlorinated public swimming pools were sampled, including indoor pools, outdoor pools and spa pools. The analyses were carried out using isotope dilution gas chromatography tandem mass spectrometry. All five PFRs were detected in swimming pool waters with concentrations ranging from 5–27 ng/L (TNBP), 7–293 ng/L (TCEP), 62–1180 ng/L (TCIPP), 10–670 ng/L (TDCIPP) and 8–132 ng/L (TPHP). The concentrations of PFRs were generally higher in indoor swimming pools compared to outdoor swimming pools. In municipal water supplies, used to fill the swimming pools in three of the sampling locations, the five PFRs were all below the limit of quantifications, eliminating this as the source. Potential leaching of PFRs from commonly used swimming equipment, including newly purchased kickboards and swimsuits was investigated. These experiments revealed that PFRs leached from swimsuits, and may be a source of PFRs in swimming pools. A quantitative risk assessment revealed that the health risk to PFRs via swimming pools was generally low and below commonly applied health risk benchmarks. - Highlights: • TNBP, TCEP, TCIPP, TDCIPP and TPHP were detected in chlorinated swimming pools. • PFRs were below the LOQ in fill water samples collected from 3 locations. • TCIPP was observed to have the highest concentrations in swimming pools. • PFRs are leaching from swimsuits and may be a source in swimming pools. • Health risks through oral and dermal exposure to PFRs in swimming pools were low.

  6. Presence and select determinants of organophosphate flame retardants in public swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Teo, Tiffany L.L., E-mail: tiffany.teo@unsw.edu.au [UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington NSW 2052 (Australia); Coleman, Heather M., E-mail: h.coleman@ulster.ac.uk [Nanotechnology and Integrated BioEngineering Centre, School of Engineering, University of Ulster, Jordanstown, County Antrim BT37 0QB, Northern Ireland (United Kingdom); Khan, Stuart J., E-mail: s.khan@unsw.edu.au [UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington NSW 2052 (Australia)

    2016-11-01

    The occurrence of five organophosphate flame retardants (PFRs) consisting of tributyl phosphate (TNBP), tris(2-chloroethyl) phosphate (TCEP), tris(1-chloro-2-propyl) phosphate (TCIPP), tris(1.3-dichloro-2-propyl) phosphate (TDCIPP) and triphenyl phosphate (TPHP) in swimming pools were investigated. Fifteen chlorinated public swimming pools were sampled, including indoor pools, outdoor pools and spa pools. The analyses were carried out using isotope dilution gas chromatography tandem mass spectrometry. All five PFRs were detected in swimming pool waters with concentrations ranging from 5–27 ng/L (TNBP), 7–293 ng/L (TCEP), 62–1180 ng/L (TCIPP), 10–670 ng/L (TDCIPP) and 8–132 ng/L (TPHP). The concentrations of PFRs were generally higher in indoor swimming pools compared to outdoor swimming pools. In municipal water supplies, used to fill the swimming pools in three of the sampling locations, the five PFRs were all below the limit of quantifications, eliminating this as the source. Potential leaching of PFRs from commonly used swimming equipment, including newly purchased kickboards and swimsuits was investigated. These experiments revealed that PFRs leached from swimsuits, and may be a source of PFRs in swimming pools. A quantitative risk assessment revealed that the health risk to PFRs via swimming pools was generally low and below commonly applied health risk benchmarks. - Highlights: • TNBP, TCEP, TCIPP, TDCIPP and TPHP were detected in chlorinated swimming pools. • PFRs were below the LOQ in fill water samples collected from 3 locations. • TCIPP was observed to have the highest concentrations in swimming pools. • PFRs are leaching from swimsuits and may be a source in swimming pools. • Health risks through oral and dermal exposure to PFRs in swimming pools were low.

  7. Analytical real-time measurement of a three-dimensional weld pool surface

    International Nuclear Information System (INIS)

    Zhang, WeiJie; Zhang, YuMing; Wang, XueWu

    2013-01-01

    The ability to observe and measure weld pool surfaces in real-time is the core of the foundation for next generation intelligent welding that can partially imitate skilled welders who observe the weld pool to acquire information on the welding process. This study aims at the real-time measurement of the specular three-dimensional (3D) weld pool surface under a strong arc in gas tungsten arc welding (GTAW). An innovative vision system is utilized in this study to project a dot-matrix laser pattern on the specular weld pool surface. Its reflection from the surface is intercepted at a distance from the arc by a diffuse plane. The intercepted laser dots illuminate this plane producing an image showing the reflection pattern. The deformation of this reflection pattern from the projected pattern (e.g. the dot matrix) is used to derive the 3D shape of the reflection surface, i.e., the weld pool surface. Based on careful analysis, the underlying reconstruction problem is formulated mathematically. An analytic solution is proposed to solve this formulated problem resulting in the weld pool surface being reconstructed on average in 3.04 ms during welding experiments. A vision-based monitoring system is thus established to measure the weld pool surface in GTAW in real-time. In order to verify the effectiveness of the proposed reconstruction algorithm, first numerical simulation is conducted. The proposed algorithm is then tested on a spherical convex mirror with a priori knowledge of its geometry. The detailed analysis of the measurement error validates the accuracy of the proposed algorithm. Results from the real-time experiments verify the robustness of the proposed reconstruction algorithm. (paper)

  8. A general framework for the regression analysis of pooled biomarker assessments.

    Science.gov (United States)

    Liu, Yan; McMahan, Christopher; Gallagher, Colin

    2017-07-10

    As a cost-efficient data collection mechanism, the process of assaying pooled biospecimens is becoming increasingly common in epidemiological research; for example, pooling has been proposed for the purpose of evaluating the diagnostic efficacy of biological markers (biomarkers). To this end, several authors have proposed techniques that allow for the analysis of continuous pooled biomarker assessments. Regretfully, most of these techniques proceed under restrictive assumptions, are unable to account for the effects of measurement error, and fail to control for confounding variables. These limitations are understandably attributable to the complex structure that is inherent to measurements taken on pooled specimens. Consequently, in order to provide practitioners with the tools necessary to accurately and efficiently analyze pooled biomarker assessments, herein, a general Monte Carlo maximum likelihood-based procedure is presented. The proposed approach allows for the regression analysis of pooled data under practically all parametric models and can be used to directly account for the effects of measurement error. Through simulation, it is shown that the proposed approach can accurately and efficiently estimate all unknown parameters and is more computational efficient than existing techniques. This new methodology is further illustrated using monocyte chemotactic protein-1 data collected by the Collaborative Perinatal Project in an effort to assess the relationship between this chemokine and the risk of miscarriage. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. 13 CFR 120.611 - Pools backing Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Pools backing Pool Certificates. 120.611 Section 120.611 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Certificates § 120.611 Pools backing Pool Certificates. (a) Pool characteristics. As set...

  10. Anticipated corrosion in the Vermont Yankee spent fuel pool

    International Nuclear Information System (INIS)

    Weeks, J.R.

    1977-06-01

    The report provides additional information relating to a proposed modification to the spent fuel pool at the Vermont Yankee Nuclear Power Station (VYNPS) and addresses corrosion of spent fuel pool storage materials and zircaloy, and provides an analysis of the effectiveness of the Boral sealing

  11. Boosting Active Contours for Weld Pool Visual Tracking in Automatic Arc Welding

    DEFF Research Database (Denmark)

    Liu, Jinchao; Fan, Zhun; Olsen, Søren Ingvor

    2015-01-01

    Detecting the shape of the non-rigid molten metal during welding, so-called weld pool visual sensing, is one of the central tasks for automating arc welding processes. It is challenging due to the strong interference of the high-intensity arc light and spatters as well as the lack of robust...... approaches to detect and represent the shape of the nonrigid weld pool. We propose a solution using active contours including an prior for the weld pool boundary composition. Also, we apply Adaboost to select a small set of features that captures the relevant information. The proposed method is applied...... to weld pool tracking and the presented results verified its feasibility....

  12. Environmental assessment, K Pool fish rearing, Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1996-12-01

    The US Department of Energy (DOE) has a need to respond to a request to lease facilities at the Hanford Site 100-KE and 100-KW filter plant pools (K Pools) for fish rearing activities. These fish rearing activities would be: (1) business ventures with public and private funds and (2) long-term enhancement and supplementation programs for game fish populations in the Columbia River Basin. The proposed action is to enter into a use permit or lease agreement with the YIN or other parties who would rear fish in the 100-K Area Pools. The proposed action would include necessary piping, pump, and electrical upgrades of the facility; cleaning and preparation of the pools; water withdrawal from the Columbia River, and any necessary water or wastewater treatment; and introduction, rearing and release of fish. Future commercial operations may be included

  13. Environmental assessment, K Pool fish rearing, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The US Department of Energy (DOE) has a need to respond to a request to lease facilities at the Hanford Site 100-KE and 100-KW filter plant pools (K Pools) for fish rearing activities. These fish rearing activities would be: (1) business ventures with public and private funds and (2) long-term enhancement and supplementation programs for game fish populations in the Columbia River Basin. The proposed action is to enter into a use permit or lease agreement with the YIN or other parties who would rear fish in the 100-K Area Pools. The proposed action would include necessary piping, pump, and electrical upgrades of the facility; cleaning and preparation of the pools; water withdrawal from the Columbia River, and any necessary water or wastewater treatment; and introduction, rearing and release of fish. Future commercial operations may be included.

  14. Pool scrubbing models for iodine components

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, K [Battelle Ingenieurtechnik GmbH, Eschborn (Germany)

    1996-12-01

    Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs.

  15. Pool scrubbing models for iodine components

    International Nuclear Information System (INIS)

    Fischer, K.

    1996-01-01

    Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs

  16. Seismic analysis of large pools

    Energy Technology Data Exchange (ETDEWEB)

    Dong, R.G.; Tokarz, F.J.

    1976-11-17

    Large pools for storing spent, nuclear fuel elements are being proposed to augment present storage capacity. To preserve the ability to isolate portions of these pools, a modularization requirement appears desirable. The purpose of this project was to investigate the effects of modularization on earthquake resistance and to assess the adequacy of current design methods for seismic loads. After determining probable representative pool geometries, three rectangular pool configurations, all 240 x 16 ft and 40 ft deep, were examined. One was unmodularized; two were modularized into 80 x 40 ft cells in one case and 80 x 80 ft cells in the other. Both embedded and above-ground installations for a hard site and embedded installations for an intermediate hard site were studied. It was found that modularization was unfavorable in terms of reducing the total structural load attributable to dynamic effects, principally because one or more cells could be left unfilled. The walls of unfilled cells would be subjected to significantly higher loads than the walls of a filled, unmodularized pool. Generally, embedded installations were preferable to above-ground installations, and the hard site was superior to the intermediate hard site. It was determined that Housner's theory was adequate for calculating hydrodynamic effects on spent fuel storage pools. Current design methods for seismic loads were found to be satisfactory when results from these methods were compared with those from LUSH analyses. As a design method for dynamic soil pressure, we found the Mononobe-Okabe theory, coupled with correction factors as suggested by Seed, to be acceptable. The factors we recommend for spent fuel storage pools are tabulated.

  17. Seismic analysis of large pools

    International Nuclear Information System (INIS)

    Dong, R.G.; Tokarz, F.J.

    1976-01-01

    Large pools for storing spent, nuclear fuel elements are being proposed to augment present storage capacity. To preserve the ability to isolate portions of these pools, a modularization requirement appears desirable. The purpose of this project was to investigate the effects of modularization on earthquake resistance and to assess the adequacy of current design methods for seismic loads. After determining probable representative pool geometries, three rectangular pool configurations, all 240 x 16 ft and 40 ft deep, were examined. One was unmodularized; two were modularized into 80 x 40 ft cells in one case and 80 x 80 ft cells in the other. Both embedded and above-ground installations for a hard site and embedded installations for an intermediate hard site were studied. It was found that modularization was unfavorable in terms of reducing the total structural load attributable to dynamic effects, principally because one or more cells could be left unfilled. The walls of unfilled cells would be subjected to significantly higher loads than the walls of a filled, unmodularized pool. Generally, embedded installations were preferable to above-ground installations, and the hard site was superior to the intermediate hard site. It was determined that Housner's theory was adequate for calculating hydrodynamic effects on spent fuel storage pools. Current design methods for seismic loads were found to be satisfactory when results from these methods were compared with those from LUSH analyses. As a design method for dynamic soil pressure, we found the Mononobe-Okabe theory, coupled with correction factors as suggested by Seed, to be acceptable. The factors we recommend for spent fuel storage pools are tabulated

  18. Tax credits and purchasing pools: will this marriage work?

    Science.gov (United States)

    Trude, S; Ginsburg, P B

    2001-04-01

    Bipartisan interest is growing in Congress for using federal tax credits to help low-income families buy health insurance. Regardless of the approach taken, tax credit policies must address risk selection issues to ensure coverage for the chronically ill. Proposals that link tax credits to purchasing pools would avoid risk selection by grouping risks similar to the way large employers do. Voluntary purchasing pools have had only limited success, however. This Issue Brief discusses linking tax credits to purchasing pools. It uses information from the Center for Studying Health System Change's (HSC) site visits to 12 communities as well as other research to assess the role of purchasing pools nationwide and the key issues and implications of linking tax credits and pools.

  19. Technical specification for fabrication of HANARO pool cover

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Woo, Sang Ik

    2001-06-01

    This technical specification details the requirements and the acceptance criteria for design, seismic analysis, function test, installation and quality assurance for HANARO pool cover which will be installed at the top of reactor pool. The pool cover is classified as non-nuclear safety, seismic category II and quality class T. The basic design of the pool cover for increasing HANARO applications has been carried out for supporting the driving devices which can load, unload and rotate the irradiation targets in the in-core and out-core vertical irradiation holes under on-power operation. The comments of HANARO user group related with irradiation tests have optimally considered in the process of design. The interference between fuel handling and control absorber units in the reactor pool and activities to load, unload and rotate the irradiation targets at the top of the reactor pool have been minimized. The pool cover can be moved for maintenance and can protect the reactor pool from unexpected drop of foreign materials. It provides the space to vertical access of driving devices for NTD, CT/IR and OR4/OR5 under on-power operation. And the pool cover assembly must maintain its structural integrity under seismic load. Based on the above design concept, the HANARO pool cover has been proposed as supporting structure of driving devices for NTD, fission moly and RI production under on-power operation.

  20. Longevity of Wood-Forced Pools in an Old-Growth Forest

    Science.gov (United States)

    Buffington, J. M.; Woodsmith, R. D.; Johnson, A. C.

    2009-12-01

    Wood debris plays an important role in scouring pools in forest channels and providing resultant habitat for aquatic organisms. We investigated the longevity of such pools in a gravel-bed river flowing through old-growth forest in southeastern Alaska by aging trees and “bear’s bread” fungi (Ganoderma applanatum, Fomitopsis pinicola) growing on pool-forming wood debris. Ages were determined by counting annual growth rings from cores and cross sections of trees and fungi growing on the wood debris. These ages are minimum values because they do not account for lag time between debris recruitment and seedling/spore establishment on the debris, nor do they account for flood scour that may periodically reset tree and fungi growth on the debris. The study stream has a gradient of about 1%, bankfull width and depth of 13.3 and 0.78 m, respectively, median grain size of 18 mm, a high wood loading (0.8 pieces/m), and a correspondingly low pool spacing (0.3 bankfull widths/pool), with 81% of the pools forced by wood debris. The size of wood debris in the study stream is large relative to the channel (average log length of 7.6 m and diameter of 0.35 m), rendering most debris immobile. Eighty-one pool-forming pieces of wood were dated over 1.2 km of stream length, with 28% of these pieces causing scour of more than one pool. In all, 122 wood-forced pools were dated, accounting for 38% of all pools at the site and 47% of the wood-forced pools. Fifty-three percent of the wood-forced pools lacked datable wood because these pieces either: were newly recruited; had been scoured by floods; or were contained below the active channel elevation, prohibiting vegetation establishment on the wood debris (the most common cause). The debris age distribution declined exponentially from 2 to 113 yrs., with a median value of 18 yrs. Similar exponential residence time distributions have been reported in other studies, but our analysis focused specifically on the ages of pool-forming wood

  1. Design of inventory pools in spare part support operation systems

    Science.gov (United States)

    Mo, Daniel Y.; Tseng, Mitchell M.; Cheung, Raymond K.

    2014-06-01

    The objective of a spare part support operation is to fulfill the part request order with different service contracts in the agreed response time. With this objective to achieve different service targets for multiple service contracts and the considerations of inventory investment, it is not only important to determine the inventory policy but also to design the structure of inventory pools and the order fulfilment strategies. In this research, we focused on two types of inventory pools: multiple inventory pool (MIP) and consolidated inventory pool (CIP). The idea of MIP is to maintain separated inventory pools based on the types of service contract, while CIP solely maintains a single inventory pool regardless of service contract. Our research aims to design the inventory pool analytically and propose reserve strategies to manage the order fulfilment risks in CIP. Mathematical models and simulation experiments would be applied for analysis and evaluation.

  2. Hawaii ESI: POOLS (Anchialine Pool Points)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains sensitive biological resource data for anchialine pools in Hawaii. Anchialine pools are small, relatively shallow coastal ponds that occur...

  3. Cash pooling

    OpenAIRE

    Lozovaya, Karina

    2009-01-01

    This work makes a mention of cash management. At next chapter describes two most known theoretical models of cash management -- Baumol Model and Miller-Orr Model. Principal part of work is about cash pooling, types of cash pooling, cash pooling at Czech Republic and influence of cash pooling over accounting and taxes.

  4. Extra-binomial variation approach for analysis of pooled DNA sequencing data

    Science.gov (United States)

    Wallace, Chris

    2012-01-01

    Motivation: The invention of next-generation sequencing technology has made it possible to study the rare variants that are more likely to pinpoint causal disease genes. To make such experiments financially viable, DNA samples from several subjects are often pooled before sequencing. This induces large between-pool variation which, together with other sources of experimental error, creates over-dispersed data. Statistical analysis of pooled sequencing data needs to appropriately model this additional variance to avoid inflating the false-positive rate. Results: We propose a new statistical method based on an extra-binomial model to address the over-dispersion and apply it to pooled case-control data. We demonstrate that our model provides a better fit to the data than either a standard binomial model or a traditional extra-binomial model proposed by Williams and can analyse both rare and common variants with lower or more variable pool depths compared to the other methods. Availability: Package ‘extraBinomial’ is on http://cran.r-project.org/ Contact: chris.wallace@cimr.cam.ac.uk Supplementary information: Supplementary data are available at Bioinformatics Online. PMID:22976083

  5. Temperature dependent fission product removal efficiency due to pool scrubbing

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Shunsuke, E-mail: suchida@iae.or.jp [Institute of Applied Energy, 1-14-2, Nishi-Shimbashi, Minato-ku, Tokyo 105-0003 (Japan); Itoh, Ayumi; Naitoh, Masanori; Okada, Hidetoshi; Suzuki, Hiroyuki [Institute of Applied Energy, 1-14-2, Nishi-Shimbashi, Minato-ku, Tokyo 105-0003 (Japan); Hanamoto, Yukio [KAKEN, Inc., 1044, Hori-machi, Mito 310-0903 (Japan); Osakabe, Masahiro [Tokyo University of Marine Science & Technology, Koutou-ku, Tokyo 135-8533 (Japan); Fujikawa, Masahiro [Japan Broadcasting Corporation, 2-2-1, Jinnan, Shibuya-ku, Tokyo 150-8001 (Japan)

    2016-03-15

    Highlights: • Pool temperature effects on the FP removal were not clearly concluded in the previous publications. • It was confirmed that the removal efficiency decreased with temperature around the boiling point. • A modified empirical formula for FP removal was proposed as a function of sub-cooling temperature. • DF could be predicted with an accuracy within a factor of 2 with the proposed formula. - Abstract: The wet-well of boiling water reactors plays important roles not only to suppress the pressure in the primary containment vessel due to steam scrubbing effects during severe accidents but also to mitigate release of radioactive fission products (FP), aerosols and particulates, into the environment. The effects of steam scrubbing in the wet-well on FP removal have been well studied and reported by changing major parameters determining the removal efficiencies, e.g., aerosol diameters, submergence (depth of scrubbing nozzles) and steam/non-condensable gas volume fraction. Unfortunately, the effects of pool temperature on the FP removal were not clearly concluded in the previous publications, though it would be easily expected that boiling in the pool resulted in reduced aerosol removal efficiency. In order to determine the temperature effects on FP removal efficiency, amounts of cesium in aerosols released from scrubbing pool were measured by changing pool temperature in mini and medium scale scrubbing experiments, and then, it was confirmed that the removal efficiency clearly decreased with temperature around the boiling point. Then, a modified empirical formula to express the FP removal around the boiling point temperature was proposed as a function of sub-cooling temperature by applying the effective steam volume fraction, which was designated as the volume ratio of condensed steam in the pool versus the sum of input steam and non-condensable gas. By comparing the measured removal efficiency with the calculated, it was validated that the

  6. Temperature dependent fission product removal efficiency due to pool scrubbing

    International Nuclear Information System (INIS)

    Uchida, Shunsuke; Itoh, Ayumi; Naitoh, Masanori; Okada, Hidetoshi; Suzuki, Hiroyuki; Hanamoto, Yukio; Osakabe, Masahiro; Fujikawa, Masahiro

    2016-01-01

    Highlights: • Pool temperature effects on the FP removal were not clearly concluded in the previous publications. • It was confirmed that the removal efficiency decreased with temperature around the boiling point. • A modified empirical formula for FP removal was proposed as a function of sub-cooling temperature. • DF could be predicted with an accuracy within a factor of 2 with the proposed formula. - Abstract: The wet-well of boiling water reactors plays important roles not only to suppress the pressure in the primary containment vessel due to steam scrubbing effects during severe accidents but also to mitigate release of radioactive fission products (FP), aerosols and particulates, into the environment. The effects of steam scrubbing in the wet-well on FP removal have been well studied and reported by changing major parameters determining the removal efficiencies, e.g., aerosol diameters, submergence (depth of scrubbing nozzles) and steam/non-condensable gas volume fraction. Unfortunately, the effects of pool temperature on the FP removal were not clearly concluded in the previous publications, though it would be easily expected that boiling in the pool resulted in reduced aerosol removal efficiency. In order to determine the temperature effects on FP removal efficiency, amounts of cesium in aerosols released from scrubbing pool were measured by changing pool temperature in mini and medium scale scrubbing experiments, and then, it was confirmed that the removal efficiency clearly decreased with temperature around the boiling point. Then, a modified empirical formula to express the FP removal around the boiling point temperature was proposed as a function of sub-cooling temperature by applying the effective steam volume fraction, which was designated as the volume ratio of condensed steam in the pool versus the sum of input steam and non-condensable gas. By comparing the measured removal efficiency with the calculated, it was validated that the

  7. Proposta do uso de pool de sangue total como controle interno de qualidade em hematologia Proposal for the use of a pool of whole blood as internal quality control in hematology

    Directory of Open Access Journals (Sweden)

    Carina Daniele Schons

    2010-06-01

    Full Text Available INTRODUÇÃO: A confiabilidade dos resultados do laboratório é garantida pela realização do controle de qualidade, que tem como funções básicas análise, pesquisa e prevenção da ocorrência de erros laboratoriais por meio de programas que abrangem tanto o controle interno quanto o externo. OBJETIVO: Propor a padronização de utilização de pool de sangue total como controle interno de qualidade no setor de hematologia. MÉTODO: Foram selecionadas amostras de sangue total, colhidas com ácido etilenodiaminotetracético (EDTA, de mesmos grupo sanguíneo e fator Rh, livres de interferentes, como hemólise, lipemia e icterícia. De um total de 30 ml de sangue total, obtiveram-se três alíquotas de 10 ml cada, às quais foram adicionados, respectivamente, 0 ml (sem adição, 1 ml e 5 ml de glicerol (conservante. As amostras foram avaliadas em contador automático ADVIA® 60. Após determinação dos valores de média e DP, todas as amostras foram avaliadas por um período de 45 dias úteis para confecção do gráfico de Levey-Jennings e verificação da estabilidade da amostra. RESULTADO E CONCLUSÃO: Podemos verificar que o pool de sangue total, preparado de acordo com a metodologia proposta, não apresenta estabilidade necessária para sua utilização, como controle interno alternativo no setor de hematologia.INTRODUCTION: The reliability of laboratory results is ensured by the implementation of quality control, which has basic functions, such as analysis, research and prevention of laboratory errors through programs that encompass both internal and external control. OBJECTIVE: To propose a standard method to use pooled whole blood as internal quality control in the Hematology division. METHOD: The selected whole blood samples were collected with EDTA, belonged to the same blood group and Rh factor and did not present interfering factors, such as hemolysis, lipemia and icterus. From a total of 30 ml of whole blood it was obtained 3

  8. Finding Biomarker Signatures in Pooled Sample Designs: A Simulation Framework for Methodological Comparisons

    Directory of Open Access Journals (Sweden)

    Anna Telaar

    2010-01-01

    Full Text Available Detection of discriminating patterns in gene expression data can be accomplished by using various methods of statistical learning. It has been proposed that sample pooling in this context would have negative effects; however, pooling cannot always be avoided. We propose a simulation framework to explicitly investigate the parameters of patterns, experimental design, noise, and choice of method in order to find out which effects on classification performance are to be expected. We use a two-group classification task and simulated gene expression data with independent differentially expressed genes as well as bivariate linear patterns and the combination of both. Our results show a clear increase of prediction error with pool size. For pooled training sets powered partial least squares discriminant analysis outperforms discriminance analysis, random forests, and support vector machines with linear or radial kernel for two of three simulated scenarios. The proposed simulation approach can be implemented to systematically investigate a number of additional scenarios of practical interest.

  9. Safety classification of systems, structures, and components for pool-type research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Ryong [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2016-08-15

    Structures, systems, and components (SSCs) important to safety of nuclear facilities shall be designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety functions. Although SSC classification guidelines for nuclear power plants have been well established and applied, those for research reactors have been only recently established by the International Atomic Energy Agency (IAEA). Korea has operated a pool-type research reactor (the High Flux Advanced Neutron Application Reactor) and has recently exported another pool-type reactor (Jordan Research and Training Reactor), which is being built in Jordan. Korea also has a plan to build one more pool-type reactor, the Kijang Research Reactor, in Kijang, Busan. The safety classification of SSCs for pool-type research reactors is proposed in this paper based on the IAEA methodology. The proposal recommends that the SSCs of pool-type research reactors be categorized and classified on basis of their safety functions and safety significance. Because the SSCs in pool-type research reactors are not the pressure-retaining components, codes and standards for design of the SSCs following the safety classification can be selected in a graded approach.

  10. 3D finite element simulation of TIG weld pool

    Science.gov (United States)

    Kong, X.; Asserin, O.; Gounand, S.; Gilles, P.; Bergheau, J. M.; Medale, M.

    2012-07-01

    The aim of this paper is to propose a three-dimensional weld pool model for the moving gas tungsten arc welding (GTAW) process, in order to understand the main factors that limit the weld quality and improve the productivity, especially with respect to the welding speed. Simulation is a very powerful tool to help in understanding the physical phenomena in the weld process. A 3D finite element model of heat and fluid flow in weld pool considering free surface of the pool and traveling speed has been developed for the GTAW process. Cast3M software is used to compute all the governing equations. The free surface of the weld pool is calculated by minimizing the total surface energy. The combined effects of surface tension gradient, buoyancy force, arc pressure, arc drag force to drive the fluid flow is included in our model. The deformation of the weld pool surface and the welding speed affect fluid flow, heat flow and thus temperature gradients and molten pool dimensions. Welding trials study is presented to compare our numerical results with macrograph of the molten pool.

  11. Solar swimming pool

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    This report examines the feasibility of using solar collectors to heat the water in a previously unheated outdoor swimming pool. The solar system is used in conjunction with a pool blanket, to conserve heat when the pool is not in use. Energy losses through evaporation can be reduced by as much as 70% by a pool blanket. A total of 130 m{sup 2} of highly durable black synthetic collectors were installed on a support structure at a 30{degree} angle from the horizontal, oriented to the south. Circulation of pool water though the collectors, which is controlled by a differential thermostat, was done with the existing pool pump. Before installation the pool temperature averaged 16{degree}C; after installation it ranged from 20{degree} to 26{degree}C. It was hard to distinguish how much pool heating was due to the solar system and how much heat was retained by the pool blanket. However, the pool season was extended by five weeks and attendance tripled. 2 figs.

  12. Welding pool measurement using thermal array sensor

    Science.gov (United States)

    Cho, Chia-Hung; Hsieh, Yi-Chen; Chen, Hsin-Yi

    2015-08-01

    Selective laser melting (SLM) is an additive manufacturing (AM) technology that uses a high-power laser beam to melt metal powder in chamber of inert gas. The process starts by slicing the 3D CAD data as a digital information source into layers to create a 2D image of each layer. Melting pool was formed by using laser irradiation on metal powders which then solidified to consolidated structure. In a selective laser melting process, the variation of melt pool affects the yield of a printed three-dimensional product. For three dimensional parts, the border conditions of the conductive heat transport have a very large influence on the melt pool dimensions. Therefore, melting pool is an important behavior that affects the final quality of the 3D object. To meet the temperature and geometry of the melting pool for monitoring in additive manufacturing technology. In this paper, we proposed the temperature sensing system which is composed of infrared photodiode, high speed camera, band-pass filter, dichroic beam splitter and focus lens. Since the infrared photodiode and high speed camera look at the process through the 2D galvanometer scanner and f-theta lens, the temperature sensing system can be used to observe the melting pool at any time, regardless of the movement of the laser spot. In order to obtain a wide temperature detecting range, 500 °C to 2500 °C, the radiation from the melting pool to be measured is filtered into a plurality of radiation portions, and since the intensity ratio distribution of the radiation portions is calculated by using black-body radiation. The experimental result shows that the system is suitable for melting pool to measure temperature.

  13. New set of convective heat transfer coefficients established for pools and validated against CLARA experiments for application to corium pools

    Energy Technology Data Exchange (ETDEWEB)

    Michel, B., E-mail: benedicte.michel@irsn.fr

    2015-05-15

    Highlights: • A new set of 2D convective heat transfer correlations is proposed. • It takes into account different horizontal and lateral superficial velocities. • It is based on previously established correlations. • It is validated against recent CLARA experiments. • It has to be implemented in a 0D MCCI (molten core concrete interaction) code. - Abstract: During an hypothetical Pressurized Water Reactor (PWR) or Boiling Water Reactor (BWR) severe accident with core meltdown and vessel failure, corium would fall directly on the concrete reactor pit basemat if no water is present. The high temperature of the corium pool maintained by the residual power would lead to the erosion of the concrete walls and basemat of this reactor pit. The thermal decomposition of concrete will lead to the release of a significant amount of gases that will modify the corium pool thermal hydraulics. In particular, it will affect heat transfers between the corium pool and the concrete which determine the reactor pit ablation kinetics. A new set of convective heat transfer coefficients in a pool with different lateral and horizontal superficial gas velocities is modeled and validated against the recent CLARA experimental program. 155 tests of this program, in two size configurations and a high range of investigated viscosity, have been used to validate the model. Then, a method to define different lateral and horizontal superficial gas velocities in a 0D code is proposed together with a discussion about the possible viscosity in the reactor case when the pool is semi-solid. This model is going to be implemented in the 0D ASTEC/MEDICIS code in order to determine the impact of the convective heat transfer in the concrete ablation by corium.

  14. Discussion on the Heat and Mass Transfer Model on the Pool Surface

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Soon-Joon; Choo, Yeon-Jun [FNC Tech., Yongin (Korea, Republic of); Ha, Sang-Jun [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Heat transfer on the pool surface involves the evaporation and condensation of steam in the presence of non-condensable gas. It is a kind of inter-phase heat transfer. This phenomenon has been regarded as less important on the thermal hydraulic behaviors such as pressure, temperature, hydrogen distribution, and so on in the nuclear reactor containment building. As a matter of fact, several RAIs (requests for additional information) during the licensing review of the developed CAP have been presented. And early in 2000s the steam condensation on the water surface of IRWST was a concern of APR1400 design. Such an increased concern is believed because it is a newly adopted system. This study discusses the pool surface heat transfer by reviewing the models of several well-known containment analysis codes, and conducting the sensitivities. This study discussed the pool surface heat transfer. The related models of CAP, GOTHIC, CONTEMPT-LT, and CONTEMPT4 were compared. The sensitivity of heat transfer coefficient for SKN3 and 4 using conventional code CONTEMPT-LT/028-A showed little effect. And the sensitivity of relative humidity and heat transfer area for latent heat transfer shows that CAP locates between GOTHIC and CONTEMPT4/MOD. The sensitivity for sensible heat transfer also shows similar trend. Conclusively, current CAP model of pool surface heat transfer has no fatal defect.

  15. Discussion on the Heat and Mass Transfer Model on the Pool Surface

    International Nuclear Information System (INIS)

    Hong, Soon-Joon; Choo, Yeon-Jun; Ha, Sang-Jun

    2016-01-01

    Heat transfer on the pool surface involves the evaporation and condensation of steam in the presence of non-condensable gas. It is a kind of inter-phase heat transfer. This phenomenon has been regarded as less important on the thermal hydraulic behaviors such as pressure, temperature, hydrogen distribution, and so on in the nuclear reactor containment building. As a matter of fact, several RAIs (requests for additional information) during the licensing review of the developed CAP have been presented. And early in 2000s the steam condensation on the water surface of IRWST was a concern of APR1400 design. Such an increased concern is believed because it is a newly adopted system. This study discusses the pool surface heat transfer by reviewing the models of several well-known containment analysis codes, and conducting the sensitivities. This study discussed the pool surface heat transfer. The related models of CAP, GOTHIC, CONTEMPT-LT, and CONTEMPT4 were compared. The sensitivity of heat transfer coefficient for SKN3 and 4 using conventional code CONTEMPT-LT/028-A showed little effect. And the sensitivity of relative humidity and heat transfer area for latent heat transfer shows that CAP locates between GOTHIC and CONTEMPT4/MOD. The sensitivity for sensible heat transfer also shows similar trend. Conclusively, current CAP model of pool surface heat transfer has no fatal defect

  16. Optimization of spent fuel pool weir gate driving mechanism

    Science.gov (United States)

    Liu, Chao; Du, Lin; Tao, Xinlei; Wang, Shijie; Shang, Ertao; Yu, Jianjiang

    2018-04-01

    Spent fuel pool is crucial facility for fuel storage and nuclear safety, and the spent fuel pool weir gate is the key related equipment. In order to achieve a goal of more efficient driving force transfer, loading during the opening/closing process is analyzed and an optimized calculation method for dimensions of driving mechanism is proposed. The result of optimizing example shows that the method can be applied to weir gates' design with similar driving mechanism.

  17. Sodium-water reaction in double pool LMFBR, (5)

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Kumagai, Hiromichi; Nishi, Yoshihisa; Uotani, Masaki

    1990-01-01

    Experiments were conducted using a 1/5 scale model of the Double Pool in order to evaluate a pressure rise caused by a large scale sodium-water reaction. The experiments were focused on the pressure rise caused by the piston motion of liquid sodium. It appeared from the results that the magnitude of this pressure rise depends on the depth of reaction point, and that a pressure rise more than 1 MPa would arise in the real Double Pool plant. A new design of steam generator is proposed to mitigate the pressure rise. (author)

  18. Competition and power pooling in the electricity industry

    International Nuclear Information System (INIS)

    Jasinski, P.; Yarrow, G.; Fusaro, P.

    1995-01-01

    Two contributions to the debate on power pooling and competition in the electricity supply industry are presented. In the first, the situation in England and Wales where power pooling was introduced shortly before privatization is analysed. Pooling has existed for many years in the USA but as an inter-generator arrangement designed to optimize production and costs. The British system sought in addition to establish a spot market in which bulk buyers as well as bulk suppliers could participate. There are however obvious weaknesses in the pool as a competitive market and it is argued that a combination of pooling arrangements and longer-term bilateral supply contracts are more likely to offer the prospect of workably competitive and efficient outcomes. The second contribution discusses how competitive markets will evolve in the USA under the new regime of less onerous regulation heralded by the Energy Policy Act if 1992 and the emergence of electricity trading markets which followed. In particular, the proposal by the California Public Utility commission favouring a mandatory Poolco is examined. Poolco would operate the transmission grid and dispatch generating plants while the utilities would retain ownership of transmission facilities and be required to supply the pool. This is seen as representing only partial deregulation and not to be consistent with moves to further competition and encourage free markets. (U.K.)

  19. Study of mixed convection in sodium pool

    International Nuclear Information System (INIS)

    Wang Zhou; Chen Yan

    1995-01-01

    The mixed convection phenomena in the sodium pool of fast reactor have been studied systematically by the two dimensional modeling method. A generalized concept of circumferential line in the cylindrical coordinates was proposed to overcome the three dimensional effect induced by the pool geometry in an analysis of two dimensional modeling. A method of sub-step in time was developed for solving the turbulent equations. The treatments on the boundary condition for the auxiliary velocity field have been proposed, and the explanation of allowing the flow function method to be used in the flow field in presence of a mass source term was given. As examples of verification, the experiments were conducted with water flow in a rectangular cavity. The results from theoretical analysis were applied to the numerical computation for the mixed convection in the cavity. The mechanism of stratified flow in the cavity was studied. A numerical calculation was carried out for the mixed convection in hot plenum of a typical fast reactor

  20. Stabilization of reactor fuel storage pool-TTP

    International Nuclear Information System (INIS)

    Sevigny, G.

    1994-10-01

    The proposed work includes evaluating standard and improved technologies an designing an integrated demonstration system to clean the water and sludge the fuel storage pools. The water released would meet drinking water standards and tritium standards. The volume of radioactive sludge would be reduced by partial separation of the sludge and radionuclides and eventual solidification of the hazardous and radioactive waste. The scope of the wo includes a survey of needs and applicable technologies, system engineering evaluation, conceptual design, detailed design, fabrication of the integrat demonstration system, and testing of the system. The survey task will locate potential specific customers within the DOE complex, and outside of the DOE complex throughout the United States, that be able to utilize the narrowly focused technology to stabilize/shutdown reactor fuel storage pools, responsible parties will be located and asked respond to a survey about their specific process requirements. Literature searches will be run through technical and scientific databases to locate technologies that may be an improvement over the standard baselined technol for cleanup of radioactively-contaminated pools. Systems engineering will provide decision analysis support for the development, evaluation, design, test functions of the treatment of pool water and sludge

  1. Stabilization of reactor fuel storage pool-TTP

    Energy Technology Data Exchange (ETDEWEB)

    Sevigny, G.

    1994-10-01

    The proposed work includes evaluating standard and improved technologies an designing an integrated demonstration system to clean the water and sludge the fuel storage pools. The water released would meet drinking water standards and tritium standards. The volume of radioactive sludge would be reduced by partial separation of the sludge and radionuclides and eventual solidification of the hazardous and radioactive waste. The scope of the wo includes a survey of needs and applicable technologies, system engineering evaluation, conceptual design, detailed design, fabrication of the integrat demonstration system, and testing of the system. The survey task will locate potential specific customers within the DOE complex, and outside of the DOE complex throughout the United States, that be able to utilize the narrowly focused technology to stabilize/shutdown reactor fuel storage pools, responsible parties will be located and asked respond to a survey about their specific process requirements. Literature searches will be run through technical and scientific databases to locate technologies that may be an improvement over the standard baselined technol for cleanup of radioactively-contaminated pools. Systems engineering will provide decision analysis support for the development, evaluation, design, test functions of the treatment of pool water and sludge.

  2. The Economic Benefits of Generation Revenue Assessment in Pool-Based Market Model for Restructured Electricity Supply Industry

    Directory of Open Access Journals (Sweden)

    Ngadiron Zuraidah

    2016-01-01

    Full Text Available The electricity supply industry had undergo deregulation and restructuring toward becoming a more transparent and competitive electricity market environment. The pool market model is amongst the most preferred electricity market model. Even though it is a safe option to be more competitive and transparent electricity supply industry, there are issues on the welfare of the generators involved. This paper addresses the pricing issue in the pool market by extending the capacity payment mechanism in the single auction power pool. In the proposed model, the approach of minimum capacity payment involving the efficiency of the generators is introduced. A case study is conducted to illustrate the proposed model. An economic analysis is performed to highlight the merits of the proposed model with the pure pool in term of generation revenue.

  3. Merging expert and empirical data for rare event frequency estimation: Pool homogenisation for empirical Bayes models

    International Nuclear Information System (INIS)

    Quigley, John; Hardman, Gavin; Bedford, Tim; Walls, Lesley

    2011-01-01

    Empirical Bayes provides one approach to estimating the frequency of rare events as a weighted average of the frequencies of an event and a pool of events. The pool will draw upon, for example, events with similar precursors. The higher the degree of homogeneity of the pool, then the Empirical Bayes estimator will be more accurate. We propose and evaluate a new method using homogenisation factors under the assumption that events are generated from a Homogeneous Poisson Process. The homogenisation factors are scaling constants, which can be elicited through structured expert judgement and used to align the frequencies of different events, hence homogenising the pool. The estimation error relative to the homogeneity of the pool is examined theoretically indicating that reduced error is associated with larger pool homogeneity. The effects of misspecified expert assessments of the homogenisation factors are examined theoretically and through simulation experiments. Our results show that the proposed Empirical Bayes method using homogenisation factors is robust under different degrees of misspecification.

  4. Pooling Objects for Recognizing Scenes without Examples

    NARCIS (Netherlands)

    Kordumova, S.; Mensink, T.; Snoek, C.G.M.

    2016-01-01

    In this paper we aim to recognize scenes in images without using any scene images as training data. Different from attribute based approaches, we do not carefully select the training classes to match the unseen scene classes. Instead, we propose a pooling over ten thousand of off-the-shelf object

  5. Test Area North Pool Stabilization Project: Environmental assessment

    International Nuclear Information System (INIS)

    1996-05-01

    The Test Area North (TAN) Pool is located within the fenced TAN facility boundaries on the Idaho National Engineering Laboratory (INEL). The TAN pool stores 344 canisters of core debris from the March, 1979, Three Mile Island (TMI) Unit 2 reactor accident; fuel assemblies from Loss-of-Fluid Tests (LOFT); and Government-owned commercial fuel rods and assemblies. The LOFT and government owned commercial fuel rods and assemblies are hereafter referred to collectively as open-quotes commercial fuelsclose quotes except where distinction between the two is important to the analysis. DOE proposes to remove the canisters of TMI core debris and commercial fuels from the TAN Pool and transfer them to the Idaho Chemical Processing Plant (ICPP) for interim dry storage until an alternate storage location other than at the INEL, or a permanent federal spent nuclear fuel (SNF) repository is available. The TAN Pool would be drained and placed in an industrially and radiologically safe condition for refurbishment or eventual decommissioning. This environmental assessment (EA) identifies and evaluates environmental impacts associated with (1) constructing an Interim Storage System (ISS) at ICPP; (2) removing the TMI and commercial fuels from the pool and transporting them to ICPP for placement in an ISS, and (3) draining and stabilizing the TAN Pool. Miscellaneous hardware would be removed and decontaminated or disposed of in the INEL Radioactive Waste Management Complex (RWMC). This EA also describes the environmental consequences of the no action alternative

  6. A scale model to evaluate water evaporation from indoor swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Asdrubali, F. [Department of Industrial Engineering, University of Perugia, Via G. Duranti 67, 06125 Perugia (Italy)

    2009-03-15

    The evaluation of water evaporation from indoor swimming pools is a topic of considerable practical interest, since evaporation may cause the highest energy consumption of the pool plant. A purposely designed experimental apparatus was used to measure the water evaporation rate from a pool scale model inserted into a climatic chamber to control environmental conditions. The experimental data were obtained varying various parameters such as water temperature, air temperature, relative humidity and air velocity. The results were used to propose a prediction model for water evaporation which was compared to other methods found in the literature, showing a good agreement. (author)

  7. Pricing Electricity in Pools With Wind Producers

    DEFF Research Database (Denmark)

    Morales González, Juan Miguel; Conejo, A. J.; Kai Liu

    2012-01-01

    This paper considers an electricity pool that includes a significant number of wind producers and is cleared through a network-constrained auction, one day in advance and on an hourly basis. The hourly auction is formulated as a two-stage stochastic programming problem, where the first stage...... represents the clearing of the market and the second stage models the system operation under a number of plausible wind production realizations. This formulation co-optimizes energy and reserve, and allows deriving both pool energy prices and balancing energy prices. These prices result in both cost recovery...... for producers and revenue reconciliation. A case study of realistic size is used to illustrate the functioning of the proposed pricing scheme....

  8. Addressing data privacy in matched studies via virtual pooling.

    Science.gov (United States)

    Saha-Chaudhuri, P; Weinberg, C R

    2017-09-07

    Data confidentiality and shared use of research data are two desirable but sometimes conflicting goals in research with multi-center studies and distributed data. While ideal for straightforward analysis, confidentiality restrictions forbid creation of a single dataset that includes covariate information of all participants. Current approaches such as aggregate data sharing, distributed regression, meta-analysis and score-based methods can have important limitations. We propose a novel application of an existing epidemiologic tool, specimen pooling, to enable confidentiality-preserving analysis of data arising from a matched case-control, multi-center design. Instead of pooling specimens prior to assay, we apply the methodology to virtually pool (aggregate) covariates within nodes. Such virtual pooling retains most of the information used in an analysis with individual data and since individual participant data is not shared externally, within-node virtual pooling preserves data confidentiality. We show that aggregated covariate levels can be used in a conditional logistic regression model to estimate individual-level odds ratios of interest. The parameter estimates from the standard conditional logistic regression are compared to the estimates based on a conditional logistic regression model with aggregated data. The parameter estimates are shown to be similar to those without pooling and to have comparable standard errors and confidence interval coverage. Virtual data pooling can be used to maintain confidentiality of data from multi-center study and can be particularly useful in research with large-scale distributed data.

  9. Congestion rents and FTR evaluations in mixed-pool-bilateral systems

    International Nuclear Information System (INIS)

    Liu, Minghai; Gross, George

    2008-01-01

    Evaluation of key metrics for congestion management, including the congestion rents and the financial transmission rights (FTR) payoffs, requires the efficient allocation of transmission services and the calculation of appropriate locational marginal prices (LMPs). This requirement is particularly acute when there are bilateral transactions coexisting with the centralized pool markets. We propose a new formulation for this purpose, which captures explicitly the contribution of the bilateral transactions to the social welfare. The proposed formulation effectively integrates the pool market and the bilateral transactions on a consistent basis and results in the more efficient allocation of the transmission resources than the conventional tool. We assess analytically the capabilities of the proposed formulation and solution and quantify the improvements in the evaluations over those done using the conventional approach. Such improvements are also illustrated using simulation results on a wide range of test systems including the IEEE 118-bus network. (author)

  10. Exciting Pools

    Science.gov (United States)

    Wright, Bradford L.

    1975-01-01

    Advocates the creation of swimming pool oscillations as part of a general investigation of mechanical oscillations. Presents the equations, procedure for deriving the slosh modes, and methods of period estimation for exciting swimming pool oscillations. (GS)

  11. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  12. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  13. Optimal Decision Making Framework of an Electric Vehicle Aggregator in Future and Pool markets

    DEFF Research Database (Denmark)

    Rashidizadeh-Kermani, Homa; Najafi, Hamid Reza; Anvari-Moghaddam, Amjad

    2018-01-01

    An electric vehicle (EV) aggregator, as an agent between power producers and EV owners, participates in the future and pool market to supply EVs’ requirement. Because of uncertain nature of pool prices and EVs’ behavior, this paper proposed a two stage scenario-based model to obtain optimal decis...... electricity markets, a sensitivity analysis over risk factor is performed. The numerical results demonstrate that with the application of the proposed model, the aggregator can supply EVs with lower purchases from markets....... decision making of an EV aggregator. To deal with mentioned uncertainties, the aggregator’s risk aversion is applied using conditional value at risk (CVaR) method in the proposed model. The proposed two stage risk-constrained decision making problem is applied to maximize EV aggregator’s expected profit...... in an uncertain environment. The aggregator can participate in the future and pool market to buy required energy of EVs and offer optimal charge/discharge prices to the EV owners. In this model, in order to assess the effects of EVs owners’ reaction to the aggregator’s offered prices on the purchases from...

  14. Parallel Algorithm of Geometrical Hashing Based on NumPy Package and Processes Pool

    Directory of Open Access Journals (Sweden)

    Klyachin Vladimir Aleksandrovich

    2015-10-01

    Full Text Available The article considers the problem of multi-dimensional geometric hashing. The paper describes a mathematical model of geometric hashing and considers an example of its use in localization problems for the point. A method of constructing the corresponding hash matrix by parallel algorithm is considered. In this paper an algorithm of parallel geometric hashing using a development pattern «pool processes» is proposed. The implementation of the algorithm is executed using the Python programming language and NumPy package for manipulating multidimensional data. To implement the process pool it is proposed to use a class Process Pool Executor imported from module concurrent.futures, which is included in the distribution of the interpreter Python since version 3.2. All the solutions are presented in the paper by corresponding UML class diagrams. Designed GeomNash package includes classes Data, Result, GeomHash, Job. The results of the developed program presents the corresponding graphs. Also, the article presents the theoretical justification for the application process pool for the implementation of parallel algorithms. It is obtained condition t2 > (p/(p-1*t1 of the appropriateness of process pool. Here t1 - the time of transmission unit of data between processes, and t2 - the time of processing unit data by one processor.

  15. Deep CNNs Along the Time Axis With Intermap Pooling for Robustness to Spectral Variations

    Science.gov (United States)

    Lee, Hwaran; Kim, Geonmin; Kim, Ho-Gyeong; Oh, Sang-Hoon; Lee, Soo-Young

    2016-10-01

    Convolutional neural networks (CNNs) with convolutional and pooling operations along the frequency axis have been proposed to attain invariance to frequency shifts of features. However, this is inappropriate with regard to the fact that acoustic features vary in frequency. In this paper, we contend that convolution along the time axis is more effective. We also propose the addition of an intermap pooling (IMP) layer to deep CNNs. In this layer, filters in each group extract common but spectrally variant features, then the layer pools the feature maps of each group. As a result, the proposed IMP CNN can achieve insensitivity to spectral variations characteristic of different speakers and utterances. The effectiveness of the IMP CNN architecture is demonstrated on several LVCSR tasks. Even without speaker adaptation techniques, the architecture achieved a WER of 12.7% on the SWB part of the Hub5'2000 evaluation test set, which is competitive with other state-of-the-art methods.

  16. Swimming-pool piles

    International Nuclear Information System (INIS)

    Trioulaire, M.

    1959-01-01

    In France two swimming-pool piles, Melusine and Triton, have just been set in operation. The swimming-pool pile is the ideal research tool for neutron fluxes of the order of 10 13 . This type of pile can be of immediate interest to many research centres, but its cost must be reduced and a break with tradition should be observed in its design. It would be an advantage: - to bury the swimming-pool; - to reject the experimental channel; - to concentrate the cooling circuit in the swimming-pool; - to carry out all manipulations in the water; - to double the core. (author) [fr

  17. The accuracy of newly proposed warning signs in the third edition of Malaysian guideline on the management of dengue infection in adult

    Directory of Open Access Journals (Sweden)

    Gary Kim Kuan Low

    2016-08-01

    Full Text Available Objective: To evaluate the accuracy of persistent vomiting and persistent diarrhoea proposed in the Malaysian dengue guideline. Methods: The eligibility criteria were dengue patients with vomiting or/and diarrhoea at the earliest day of illness without other warning signs. Vomiting and diarrhoea categorised by three or more episodes over 24 h were considered as warning signs. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Results: There were a total of 479 patients, of whom 36 (7.5% got severe dengue and 443 (92.5% got dengue with warning signs. The overall accuracy ranged from 33.3% to 72.7% for sensitivity, 28.8% to 56.5% for specificity, 1.8% to 14.5% for positive predictive value and 88.5% to 96.3% for negative predictive value. There were 16 false negative. Conclusions: The newly proposed warning signs in the third edition of Malaysian dengue guideline may not be effective in predicting severe dengue.

  18. Spent fuel storage pool

    International Nuclear Information System (INIS)

    Murakami, Naoshi.

    1996-01-01

    Fences are disposed to a fuel exchange floor surrounding the upper surface of a fuel pool for preventing overflow of pool water. The fences comprise a plurality of flat boards arranged in parallel with each other in the longitudinal direction while being vertically inclined, and slits are disposed between the boards for looking down the pool. Further, the fences comprise wide boards and are constituted so as to be laid horizontally on the fuel exchange floor in a normal state and uprisen by means of the signals from an earthquake sensing device. Even if pool water is overflow from the fuel pool by the vibrations occurred upon earthquake and flown out to the floor of the fuel exchange floor, the overflow from the fuel exchange floor is prevented by the fences. An operator who monitors the fuel pool can observe the inside of the fuel pool through the slits formed to the fences during normal operation. The fences act as resistance against overflowing water upon occurrence of an earthquake thereby capable of reducing the overflowing amount of water due to the vibrations of pool water. The effect of preventing overflowing water can be enhanced. (N.H.)

  19. Effective Momentum and heat flux models for simulation of stratification and mixing in a large pool of water

    Energy Technology Data Exchange (ETDEWEB)

    Hua Li; Villanueva, W.; Kudinov, P. [Royal Institute of Technology (KTH). Div. of Nuclear Power Safety, Stockholm (Sweden)

    2012-06-15

    Performance of a boiling water reactor (BWR) containment is mostly determined by reliable operation of pressure suppression pool which serves as a heat sink to cool and condense steam released from the core vessel. Thermal stratification in the pool can significantly impede the pool's pressure suppression capacity. A source of momentum is required in order to break stratification and mix the pool. It is important to have reliable prediction of transient development of stratification and mixing in the pool in different regimes of steam injection. Previously, we have proposed to model the effect of steam injection on the mixing and stratification with the Effective Heat Source (EHS) and the Effective Momentum Source (EMS) models. The EHS model is used to provide thermal effect of steam injection on the pool, preserving heat and mass balance. The EMS model is used to simulate momentum induced by steam injection in different flow regimes. The EMS model is based on the combination of (1) synthetic jet theory, which predicts effective momentum if amplitude and frequency of flow oscillations in the pipe are given, and (2) model proposed by Aya and Nariai for prediction of the amplitude and frequency of oscillations at a given pool temperature and steam mass flux. The complete EHS/EMS models only require the steam mass flux, initial pool bulk temperature, and design-specific parameters, to predict thermal stratification and mixing in a pressure suppression pool. In this work we use EHS/EMS models implemented in containment thermal hydraulic code GOTHIC. The POOLEX/PPOOLEX experiments (Lappeenranta University of Technology, Finland) are utilized, to (a) quantify errors due to GOTHIC's physical models and numerical schemes, (b) propose necessary improvements in GOTHIC sub-grid scale modeling, and (c) validate our proposed models. Specifically the data from POOLEX STB-21 and PPOOLEX STR-03 and STR-04 tests are used for validation of the EHS and EMS models in this

  20. Effective Momentum and heat flux models for simulation of stratification and mixing in a large pool of water

    International Nuclear Information System (INIS)

    Hua Li; Villanueva, W.; Kudinov, P.

    2012-06-01

    Performance of a boiling water reactor (BWR) containment is mostly determined by reliable operation of pressure suppression pool which serves as a heat sink to cool and condense steam released from the core vessel. Thermal stratification in the pool can significantly impede the pool's pressure suppression capacity. A source of momentum is required in order to break stratification and mix the pool. It is important to have reliable prediction of transient development of stratification and mixing in the pool in different regimes of steam injection. Previously, we have proposed to model the effect of steam injection on the mixing and stratification with the Effective Heat Source (EHS) and the Effective Momentum Source (EMS) models. The EHS model is used to provide thermal effect of steam injection on the pool, preserving heat and mass balance. The EMS model is used to simulate momentum induced by steam injection in different flow regimes. The EMS model is based on the combination of (1) synthetic jet theory, which predicts effective momentum if amplitude and frequency of flow oscillations in the pipe are given, and (2) model proposed by Aya and Nariai for prediction of the amplitude and frequency of oscillations at a given pool temperature and steam mass flux. The complete EHS/EMS models only require the steam mass flux, initial pool bulk temperature, and design-specific parameters, to predict thermal stratification and mixing in a pressure suppression pool. In this work we use EHS/EMS models implemented in containment thermal hydraulic code GOTHIC. The POOLEX/PPOOLEX experiments (Lappeenranta University of Technology, Finland) are utilized, to (a) quantify errors due to GOTHIC's physical models and numerical schemes, (b) propose necessary improvements in GOTHIC sub-grid scale modeling, and (c) validate our proposed models. Specifically the data from POOLEX STB-21 and PPOOLEX STR-03 and STR-04 tests are used for validation of the EHS and EMS models in this work. We

  1. Simulation and optimization methods for logistics pooling in the outbound supply chain

    OpenAIRE

    Jesus Gonzalez-Feliu; Carlos Peris-Pla; Dina Rakotonarivo

    2010-01-01

    International audience; Logistics pooling and collaborative transportation systems are relatively new concepts in logistics research, but are very popular in practice. This communication proposes a conceptual framework for logistics and transportation pooling systems, as well as a simulation method for strategic planning optimization. This method is based on a twostep constructive heuristic in order to estimate for big instances the transportation and storage costs at a macroscopic level. Fou...

  2. Dynamic simulation and thermo-economic analysis of a PhotoVoltaic/Thermal collector heating system for an indoor–outdoor swimming pool

    International Nuclear Information System (INIS)

    Buonomano, Annamaria; De Luca, Giuseppina; Figaj, Rafal Damian; Vanoli, Laura

    2015-01-01

    Highlights: • A PV/T heating system for indoor–outdoor swimming pools is proposed. • A comparison among some thermal pool models available in literature is carried out. • Dynamic simulations of the thermal behavior of the swimming-pools are performed. • PV/T thermal energy is used to heat the swimming pool and for DHW production. • Energy and economic parametric analyses of the proposed system are presented. - Abstract: This paper presents an analysis of an innovative renewable energy plant serving an existing indoor/outdoor swimming pool located in Naples. The proposed solar hybrid system is designed in order to balance the remarkable energy demand of the swimming pool facility and to ensure suitable comfort conditions for swimmers. With the aim to accomplish such goals, the dynamic thermal behavior of the swimming pool was analyzed as a function of the thermo-hygrometric conditions of the indoor space and on the meteorological conditions of the pool site. In order to properly design and size the proposed renewable energy system, different thermal pool loss formulations for the calculation of the swimming pool thermal balance, in indoor and outdoor regimes, are adopted. The solar hybrid system consists of a water cooled photovoltaic/thermal collectors plant (PV/T), designed to meet a part of the facility demands of electricity and heat. Electricity is completely utilized by the facility, while the produced thermal energy is primarily used to meet the pool thermal demand and secondarily for sanitary hot water scopes. In order to carry out dynamic simulations and sensitivity analyses, the system performance is designed and dynamically simulated in TRNSYS environment. The developed simulation model enables the calculation of both the indoor and outdoor swimming pool thermal losses and the overall energy and economic system performance. Such results are obtained as a function of the thermo-hygrometric conditions of the environment, of the occupants and the

  3. Experimental investigation of tube length effect on nucleate pool boiling heat transfer

    International Nuclear Information System (INIS)

    Kang, Myeong-Gie

    1998-01-01

    The effect of a vertically installed tube length on the nucleate pool boiling heat transfer coefficient under atmospheric pressure has been empirically obtained using various combination of major parameters for application to advanced light water reactor design. The experimental data for q'' versus ΔT test are counted as 1,063 points and can cover the extent of D = 9.7 ∼ 25.4 mm, ε = 15.1 ∼ 60.9 nm, H = 5.25 ∼ 30.93, and q'' ≤ 160 kW/m 2 . The experimental results show that a shorter tube is more efficient to increase heat transfer rate due to smaller bubble slug formation on the tube surface. The effect of tube length is greatly observed before H(= L/D) gets 50. After that, the heat flux decreases linearly with H increase. To quantify tube length effect, a new empirical correlation has been developed based on the experimental data bank for pool boiling heat transfer and some parametric studies have been done using the newly developed empirical correlation to broaden its applicability. The newly developed empirical correlation has the form of q'' 0.019ε 0.570 ΔT 4.676 /(D 1.238 H 0.072 ) and can predict the experimental data within ± 20% bound. Heat transfer characteristics can be changed with tube length variation and the transition point is H ∼ 50. Before the transition point, bubble coalescence is active and heat transfer rate gets rapidly decreased with increasing tube length. After that, heat transfer gets somewhat slowly decreased since bubble coalescence effect gets nearly equilibrium with liquid agitation effect

  4. Reracking Possibilities of the NPP Krsko Spent Fuel Pool

    International Nuclear Information System (INIS)

    Bace, M.; Pevec, D.; Smuc, T.

    1998-01-01

    Using the SCALE-4 code package reracking possibilities of the NPP Krsko spent fuel pool were analyzed. Two cases were considered: the first case assuming the 40 years lifetime of the plant, and the second case assuming the 50 years lifetime of the plant. It was shown that it is possible to design the additional racks in free space of the spent fuel pool with the sufficient total capacity to store all the spent fuel generated during the 40 years lifetime of the plant. In the case of 50 years plant lifetime, completely new racks (capacity of 1890 spent fuel assemblies), containing 4mm boral in storage cell walls, were proposed for the NPP Krsko spent fuel pool. The effective multiplication factor of the spent fuel pool fully loaded with new racks containing spent fuel assemblies of initial enrichment 4.3 w/o, burned to 40 GWd/tU and cooled 2 years is lower than the value required by standard. It showed the possibility of the safe disposal of all spent fuel accumulated during more than 50 years lifetime of the plant. (author)

  5. Study on Dynamic Development of Three-dimensional Weld Pool Surface in Stationary GTAW

    Science.gov (United States)

    Huang, Jiankang; He, Jing; He, Xiaoying; Shi, Yu; Fan, Ding

    2018-04-01

    The weld pool contains abundant information about the welding process. In particular, the type of the weld pool surface shape, i. e., convex or concave, is determined by the weld penetration. To detect it, an innovative laser-vision-based sensing method is employed to observe the weld pool surface of the gas tungsten arc welding (GTAW). A low-power laser dots pattern is projected onto the entire weld pool surface. Its reflection is intercepted by a screen and captured by a camera. Then the dynamic development process of the weld pool surface can be detected. By observing and analyzing, the change of the reflected laser dots reflection pattern, for shape of the weld pool surface shape, was found to closely correlate to the penetration of weld pool in the welding process. A mathematical model was proposed to correlate the incident ray, reflected ray, screen and surface of weld pool based on structured laser specular reflection. The dynamic variation of the weld pool surface and its corresponding dots laser pattern were simulated and analyzed. By combining the experimental data and the mathematical analysis, the results show that the pattern of the reflected laser dots pattern is closely correlated to the development of weld pool, such as the weld penetration. The concavity of the pool surface was found to increase rapidly after the surface shape was changed from convex to concave during the stationary GTAW process.

  6. Operation and maintenance techniques of pool and pool water purification system in IMEF

    Energy Technology Data Exchange (ETDEWEB)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs.

  7. Operation and maintenance techniques of pool and pool water purification system in IMEF

    International Nuclear Information System (INIS)

    Soong, Woong Sup

    1999-03-01

    IMEF pool is used pass way between pool and hot cell in order to inlet and outlet of fuel pin in cask. All operation is performed conforming with naked eyes. Therefore floating matter is filtered so as to easy under water handling. Also radioactivity in pool water is controlled according to the nuclear law, radioactivity ration maintained less than 15mR/hr on pool side. Perfect operation and maintenance can be achieved well trained operator. Result obtained from the perfection can give more influence over restrain, spreading contamination of radioactivity materials. This report describes operation and maintenance technique of pool water purification system in IMEF. (Author). 7 refs., 13 figs

  8. Direct Numerical Simulation and Visualization of Subcooled Pool Boiling

    Directory of Open Access Journals (Sweden)

    Tomoaki Kunugi

    2014-01-01

    Full Text Available A direct numerical simulation of the boiling phenomena is one of the promising approaches in order to clarify their heat transfer characteristics and discuss the mechanism. During these decades, many DNS procedures have been developed according to the recent high performance computers and computational technologies. In this paper, the state of the art of direct numerical simulation of the pool boiling phenomena during mostly two decades is briefly summarized at first, and then the nonempirical boiling and condensation model proposed by the authors is introduced into the MARS (MultiInterface Advection and Reconstruction Solver developed by the authors. On the other hand, in order to clarify the boiling bubble behaviors under the subcooled conditions, the subcooled pool boiling experiments are also performed by using a high speed and high spatial resolution camera with a highly magnified telescope. Resulting from the numerical simulations of the subcooled pool boiling phenomena, the numerical results obtained by the MARS are validated by being compared to the experimental ones and the existing analytical solutions. The numerical results regarding the time evolution of the boiling bubble departure process under the subcooled conditions show a very good agreement with the experimental results. In conclusion, it can be said that the proposed nonempirical boiling and condensation model combined with the MARS has been validated.

  9. Swimming pool granuloma

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001357.htm Swimming pool granuloma To use the sharing features on this page, please enable JavaScript. A swimming pool granuloma is a long-term (chronic) skin ...

  10. Visual attention and flexible normalization pools

    Science.gov (United States)

    Schwartz, Odelia; Coen-Cagli, Ruben

    2013-01-01

    Attention to a spatial location or feature in a visual scene can modulate the responses of cortical neurons and affect perceptual biases in illusions. We add attention to a cortical model of spatial context based on a well-founded account of natural scene statistics. The cortical model amounts to a generalized form of divisive normalization, in which the surround is in the normalization pool of the center target only if they are considered statistically dependent. Here we propose that attention influences this computation by accentuating the neural unit activations at the attended location, and that the amount of attentional influence of the surround on the center thus depends on whether center and surround are deemed in the same normalization pool. The resulting form of model extends a recent divisive normalization model of attention (Reynolds & Heeger, 2009). We simulate cortical surround orientation experiments with attention and show that the flexible model is suitable for capturing additional data and makes nontrivial testable predictions. PMID:23345413

  11. Swimming pool hydraulics and their significance for public pools. Bedeutung der Beckenhydraulik in oeffentlichen Schwimmbaedern

    Energy Technology Data Exchange (ETDEWEB)

    Gansloser, G

    1989-11-01

    The term of swimming pool hydraulics means the process of letting in and drawing off water to and from the pool while ensuring that no inadmissible water-borne contaminant concentrations will occur anywhere within the pool. Measurements were performed on a pool to study the significance of correct pool hydraulics. The author points out that a wrong water recirculation design will bring to nought the effects of an elaborate water treatment system; by contrast, poor pool water quality can be greatly improved by redesigning the pool water hydraulics approach. In principle, systems with with water inlet at one side and water outlet at the far side will fall short of hygienic requirements. (BWI).

  12. Modeling of condensation, stratification, and mixing phenomena in a pool of water

    Energy Technology Data Exchange (ETDEWEB)

    Li, H.; Kudinov, P.; Villanueva, W. (Royal Institute of Technology (KTH). Div. of Nuclear Power Safety, Stockholm (Sweden))

    2010-12-15

    ) propose necessary improvements in GOTHIC sub-grid scale modeling. The study performed on thermal stratification in a water pool indicates that GOTHIC CFD-like model is fit for reactor applications in complex fluidphysics scenarios that avoids both over-simplification (as in single lumpedparameter model) and over-complication (as in CFD models). However, simulation of direct steam injection into a subcooled pool cannot be predicted reliably with the existing models. Thus we develop 'effective heat source' and 'effective momentum' approaches, and provide feasibility study for the prediction of thermal stratification and mixing in a BWR pressure suppression pool. The results are encouraging and further activity on the development and implementation of the proposed models in GOTHIC is currently underway. (Author)

  13. PDA: Pooled DNA analyzer

    Directory of Open Access Journals (Sweden)

    Lin Chin-Yu

    2006-04-01

    Full Text Available Abstract Background Association mapping using abundant single nucleotide polymorphisms is a powerful tool for identifying disease susceptibility genes for complex traits and exploring possible genetic diversity. Genotyping large numbers of SNPs individually is performed routinely but is cost prohibitive for large-scale genetic studies. DNA pooling is a reliable and cost-saving alternative genotyping method. However, no software has been developed for complete pooled-DNA analyses, including data standardization, allele frequency estimation, and single/multipoint DNA pooling association tests. This motivated the development of the software, 'PDA' (Pooled DNA Analyzer, to analyze pooled DNA data. Results We develop the software, PDA, for the analysis of pooled-DNA data. PDA is originally implemented with the MATLAB® language, but it can also be executed on a Windows system without installing the MATLAB®. PDA provides estimates of the coefficient of preferential amplification and allele frequency. PDA considers an extended single-point association test, which can compare allele frequencies between two DNA pools constructed under different experimental conditions. Moreover, PDA also provides novel chromosome-wide multipoint association tests based on p-value combinations and a sliding-window concept. This new multipoint testing procedure overcomes a computational bottleneck of conventional haplotype-oriented multipoint methods in DNA pooling analyses and can handle data sets having a large pool size and/or large numbers of polymorphic markers. All of the PDA functions are illustrated in the four bona fide examples. Conclusion PDA is simple to operate and does not require that users have a strong statistical background. The software is available at http://www.ibms.sinica.edu.tw/%7Ecsjfann/first%20flow/pda.htm.

  14. Localization and movement of newly synthesized cholesterol in rat ovarian granulosa cells

    International Nuclear Information System (INIS)

    Lange, Y.; Schmit, V.M.; Schreiber, J.R.

    1988-01-01

    The distribution and movement of cholesterol were studied in granulosa cells from the ovaries of estrogen-stimulated hypophysectomized immature rats cultured in serum-free medium. Plasma membrane cholesterol was distinguished from intracellular cholesterol with cholesterol oxidase, an enzyme that converts cell surface cholesterol to cholestenone, leaving intracellular cholesterol untouched. Using this approach we showed that 82% of unesterified cholesterol was associated with the plasma membrane in granulosa cells cultured for 48 h in serum-free medium in both the presence and absence of added androstenedione and FSH. FSH and androstenedione stimulated a marked increase in steroid hormone (progestin) production. The movement of newly synthesized cholesterol to the plasma membrane also was followed using cholesterol oxidase. Newly synthesized cholesterol reached the plasma membrane too rapidly to be measured in unstimulated cells (t1/2 less than 20 min); however, in cells stimulated by FSH and androstenedione, this rate was considerably slower (t1/2 approximately 2h). Therefore, cholesterol movement to the plasma membrane appears to be regulated by gonadotropins in these cells. We tested whether steroid biosynthesis used all cell cholesterol pools equally. To this end we administered [3H]acetate and [14C]acetate at different times and determined their relative specific contents in various steroids after defined intervals. The relative ages of the steroids (youngest to oldest) were: lanosterol, progestins, intracellular cholesterol, and plasma membrane cholesterol. This finding suggests that progestins use newly synthesized intracellular cholesterol in preference to preexisting intracellular or cell surface cholesterol

  15. 13 CFR 120.1706 - Pool Originator's retained interest in Pool.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Pool Originator's retained interest in Pool. 120.1706 Section 120.1706 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan...

  16. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    Science.gov (United States)

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  17. Validation of effective momentum and heat flux models for stratification and mixing in a water pool

    Energy Technology Data Exchange (ETDEWEB)

    Hua Li; Villanueva, W.; Kudinov, P. [Royal Institute of Technology (KTH), Div. of Nuclear Power Safety, Stockholm (Sweden)

    2013-06-15

    The pressure suppression pool is the most important feature of the pressure suppression system in a Boiling Water Reactor (BWR) that acts primarily as a passive heat sink during a loss of coolant accident (LOCA) or when the reactor is isolated from the main heat sink. The steam injection into the pool through the blowdown pipes can lead to short term dynamic phenomena and long term thermal transient in the pool. The development of thermal stratification or mixing in the pool is a transient phenomenon that can influence the pool's pressure suppression capacity. Different condensation regimes depending on the pool's bulk temperature and steam flow rates determine the onset of thermal stratification or erosion of stratified layers. Previously, we have proposed to model the effect of steam injection on the mixing and stratification with the Effective Heat Source (EHS) and the Effective Momentum Source (EMS) models. The EHS model is used to provide thermal effect of steam injection on the pool, preserving heat and mass balance. The EMS model is used to simulate momentum induced by steam injection in different flow regimes. The EMS model is based on the combination of (i) synthetic jet theory, which predicts effective momentum if amplitude and frequency of flow oscillations in the pipe are given, and (ii) model proposed by Aya and Nariai for prediction of the amplitude and frequency of oscillations at a given pool temperature and steam mass flux. The complete EHS/EMS models only require the steam mass flux, initial pool bulk temperature, and design-specific parameters, to predict thermal stratification and mixing in a pressure suppression pool. In this work we use EHS/EMS models implemented in containment thermal hydraulic code GOTHIC. The PPOOLEX experiments (Lappeenranta University of Technology, Finland) are utilized to (a) quantify errors due to GOTHIC's physical models and numerical schemes, (b) propose necessary improvements in GOTHIC sub-grid scale

  18. Experimental investigation of particulate debris spreading in a pool

    Energy Technology Data Exchange (ETDEWEB)

    Konovalenko, A., E-mail: kono@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Basso, S., E-mail: simoneb@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Kudinov, P., E-mail: pkudinov@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology (KTH) , Roslagstullsbacken 21, Stockholm 106 91 (Sweden); Yakush, S.E., E-mail: yakush@ipmnet.ru [Institute for Problems in Mechanics of the Russian Academy of Sciences, Ave. Vernadskogo 101 Bldg 1, Moscow 119526 (Russian Federation)

    2016-02-15

    Termination of severe accident progression by core debris cooling in a deep pool of water under reactor vessel is considered in several designs of light water reactors. However, success of this accident mitigation strategy is contingent upon the effectiveness of heat removal by natural circulation from the debris bed. It is assumed that a porous bed will be formed in the pool in the process of core melt fragmentation and quenching. Debris bed coolability depends on its properties and system conditions. The properties of the bed, including its geometry are the outcomes of the debris bed formation process. Spreading of the debris particles in the pool by two-phase turbulent flows induced by the heat generated in the bed can affect the shape of the bed and thus influence its coolability. The goal of this work is to provide experimental data on spreading of solid particles in the pool by large-scale two-phase flow. The aim is to provide data necessary for understanding of separate effects and for development and validation of models and codes. Validated codes can be then used for prediction of debris bed formation under prototypic severe accident conditions. In PDS-P (Particulate Debris Spreading in the Pool) experiments, air injection at the bottom of the test section is employed as a means to create large-scale flow in the pool in isothermal conditions. The test section is a rectangular tank with a 2D slice geometry, it has fixed width (72 mm), adjustable length (up to 1.5 m) and allows water filling to the depth of up to 1 m. Variable pool length and depth allows studying two-phase circulating flows of different characteristic sizes and patterns. The average void fraction in the pool is determined by video recording and subsequent image processing. Particles are supplied from the top of the facility above the water surface. Results of several series of PDS-P experiments are reported in this paper. The influence of the gas flow rate, pool dimensions, particle density

  19. Flagellation of Pseudomonas aeruginosa in newly divided cells

    Science.gov (United States)

    Zhao, Kun; Lee, Calvin; Anda, Jaime; Wong, Gerard

    2015-03-01

    For monotrichous bacteria, Pseudomonas aeruginosa, after cell division, one daughter cell inherits the old flagellum from its mother cell, and the other grows a new flagellum during or after cell division. It had been shown that the new flagellum grows at the distal pole of the dividing cell when the two daughter cells haven't completely separated. However, for those daughter cells who grow new flagella after division, it still remains unknown at which pole the new flagellum will grow. Here, by combining our newly developed bacteria family tree tracking techniques with genetic manipulation method, we showed that for the daughter cell who did not inherit the old flagellum, a new flagellum has about 90% chances to grow at the newly formed pole. We proposed a model for flagellation of P. aeruginosa.

  20. Benthic assemblages of rock pools in northern Portugal: seasonal and between-pool variability

    Directory of Open Access Journals (Sweden)

    Iacopo Bertocci

    2012-11-01

    Full Text Available We investigated the seasonal (winter vs summer and within season and spatial (between-pool variability of benthic assemblages of rock pools at mid-intertidal level along the shore of Viana do Castelo (North Portugal. Physical traits of rock pools, including size, depth and position along the shore, were also compared between pools. While pools did not differ for any of the examined physical traits, results indicated a clear seasonal difference in the structure of assemblages, including a total of 49 macroalgal and 13 animal taxa. This finding was driven by six taxa that are more abundant in winter (the reef-forming polychaete Sabellaria alveolata, the articulated coralline algae Corallina spp., the brown alga Bifurcaria bifurcata, the encrusting coralline alga Lithophyllum incrustans, the red alga Chondracanthus acicularis and the grazing snails Gibbula spp. and four algal taxa that are more abundant in summer (the invasive brown Sargassum muticum, the green Ulva spp., the kelp Laminaria ochroleuca and the filamentous red Ceramium spp.. These data provide a new contribution to the knowledge of rock pool systems and have potential implications for monitoring programmes aimed at assessing ecological modifications related to natural and anthropogenic disturbances and for identifying processes responsible for the variability of rock pool assemblages.

  1. Vision-based weld pool boundary extraction and width measurement during keyhole fiber laser welding

    Science.gov (United States)

    Luo, Masiyang; Shin, Yung C.

    2015-01-01

    In keyhole fiber laser welding processes, the weld pool behavior is essential to determining welding quality. To better observe and control the welding process, the accurate extraction of the weld pool boundary as well as the width is required. This work presents a weld pool edge detection technique based on an off axial green illumination laser and a coaxial image capturing system that consists of a CMOS camera and optic filters. According to the difference of image quality, a complete developed edge detection algorithm is proposed based on the local maximum gradient of greyness searching approach and linear interpolation. The extracted weld pool geometry and the width are validated by the actual welding width measurement and predictions by a numerical multi-phase model.

  2. poolHiTS: A Shifted Transversal Design based pooling strategy for high-throughput drug screening

    Directory of Open Access Journals (Sweden)

    Woolf Peter J

    2008-05-01

    Full Text Available Abstract Background A key goal of drug discovery is to increase the throughput of small molecule screens without sacrificing screening accuracy. High-throughput screening (HTS in drug discovery involves testing a large number of compounds in a biological assay to identify active compounds. Normally, molecules from a large compound library are tested individually to identify the activity of each molecule. Usually a small number of compounds are found to be active, however the presence of false positive and negative testing errors suggests that this one-drug one-assay screening strategy can be significantly improved. Pooling designs are testing schemes that test mixtures of compounds in each assay, thereby generating a screen of the whole compound library in fewer tests. By repeatedly testing compounds in different combinations, pooling designs also allow for error-correction. These pooled designs, for specific experiment parameters, can be simply and efficiently created using the Shifted Transversal Design (STD pooling algorithm. However, drug screening contains a number of key constraints that require specific modifications if this pooling approach is to be useful for practical screen designs. Results In this paper, we introduce a pooling strategy called poolHiTS (Pooled High-Throughput Screening which is based on the STD algorithm. In poolHiTS, we implement a limit on the number of compounds that can be mixed in a single assay. In addition, we show that the STD-based pooling strategy is limited in the error-correction that it can achieve. Due to the mixing constraint, we show that it is more efficient to split a large library into smaller blocks of compounds, which are then tested using an optimized strategy repeated for each block. We package the optimal block selection algorithm into poolHiTS. The MATLAB codes for the poolHiTS algorithm and the corresponding decoding strategy are also provided. Conclusion We have produced a practical version

  3. An accurate clone-based haplotyping method by overlapping pool sequencing.

    Science.gov (United States)

    Li, Cheng; Cao, Changchang; Tu, Jing; Sun, Xiao

    2016-07-08

    Chromosome-long haplotyping of human genomes is important to identify genetic variants with differing gene expression, in human evolution studies, clinical diagnosis, and other biological and medical fields. Although several methods have realized haplotyping based on sequencing technologies or population statistics, accuracy and cost are factors that prohibit their wide use. Borrowing ideas from group testing theories, we proposed a clone-based haplotyping method by overlapping pool sequencing. The clones from a single individual were pooled combinatorially and then sequenced. According to the distinct pooling pattern for each clone in the overlapping pool sequencing, alleles for the recovered variants could be assigned to their original clones precisely. Subsequently, the clone sequences could be reconstructed by linking these alleles accordingly and assembling them into haplotypes with high accuracy. To verify the utility of our method, we constructed 130 110 clones in silico for the individual NA12878 and simulated the pooling and sequencing process. Ultimately, 99.9% of variants on chromosome 1 that were covered by clones from both parental chromosomes were recovered correctly, and 112 haplotype contigs were assembled with an N50 length of 3.4 Mb and no switch errors. A comparison with current clone-based haplotyping methods indicated our method was more accurate. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  4. Depth-variable settlement patterns and predation influence on newly settled reef fishes (Haemulon spp., Haemulidae.

    Directory of Open Access Journals (Sweden)

    Lance K B Jordan

    Full Text Available During early demersal ontogeny, many marine fishes display complex habitat-use patterns. Grunts of the speciose genus Haemulon are among the most abundant fishes on western North Atlantic coral reefs, with most species settling to shallow habitats (≤12 m. To gain understanding into cross-shelf distributional patterns exhibited by newly settled stages of grunts (<2 cm total length, we examined: 1 depth-specific distributions of congeners at settlement among sites at 8 m, 12 m, and 21 m, and 2 depth-variable predation pressure on newly settled individuals (species pooled. Of the six species identified from collections of newly settled specimens (n = 2125, Haemulon aurolineatum (tomtate, H. flavolineatum (French grunt, and H. striatum (striped grunt comprised 98% of the total abundance; with the first two species present at all sites. Prevalence of H. aurolineatum and H. flavolineatum decreased substantially from the 8-m site to the two deeper sites. In contrast, H. striatum was absent from the 8-m site and exhibited its highest frequency at the 21-m site. Comparison of newly settled grunt delta density for all species on caged (predator exclusion and control artificial reefs at the shallowest site (8-m revealed no difference, while the 12-m and 21-m sites exhibited significantly greater delta densities on the caged treatment. This result, along with significantly higher abundances of co-occurring piscivorous fishes at the deeper sites, indicated lower predation pressure at the 8-m site. This study suggests habitat-use patterns of newly settled stages of some coral reef fishes that undergo ontogenetic shifts are a function of depth-variable predation pressure while, for at least one deeper-water species, proximity to adult habitat appears to be an important factor affecting settlement distribution.

  5. Pool scrubbing

    International Nuclear Information System (INIS)

    Lopez-Jimenez, J.; Herranz, J.; Escudero, M.J.; Espigares, M.M.; Peyres, V.; Polo, J.; Kortz, Ch.; Koch, M.K.; Brockmeier, U.; Unger, H.; Dutton, L.M.C.; Smedley, Ch.; Trow, W.; Jones, A.V.; Bonanni, E.; Calvo, M.; Alonso, A.

    1996-12-01

    The Source Term Project in the Third Frame Work Programme of the European Union Was conducted under and important joined effort on pool scrubbing research. CIEMAT was the Task Manager of the project and several other organizations participated in it: JRC-Ispra, NNC Limited, RUB-NES and UPM. The project was divided into several tasks. A peer review of the models in the pool scrubbing codes SPARC90 and BUSCA-AUG92 was made, considering the different aspects in the hydrodynamic phenomenology, particle retention and fission product vapor abortions. Several dominant risk accident sequences were analyzed with MAAP, SPARC90 and BUSCA-AUG92 codes, and the predictions were compared. A churn-turbulent model was developed for the hydrodynamic behaviour of the pool. Finally, an experimental programme in the PECA facility of CIEMAT was conducted in order to study the decontamination factor under jet injection regime, and the experimental observations were compared with the SPARC and BUSCA codes. (Author)

  6. Characterization of PCBs from computers and mobile phones, and the proposal of newly developed materials for substitution of gold, lead and arsenic.

    Science.gov (United States)

    Dervišević, Irma; Minić, Duško; Kamberović, Željko; Ćosović, Vladan; Ristić, Mirjana

    2013-06-01

    In this paper, we have analyzed parts of printed circuit board (PCB) and liquid crystal display (LCD) screens of mobile phones and computers, quantitative and qualitative chemical compositions of individual components, and complete PCBs were determined. Differential thermal analysis (DTA) and differential scanning calorimetry (DSC) methods were used to determine the temperatures of phase transformations, whereas qualitative and quantitative compositions of the samples were determined by X-ray fluorescence spectrometry (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and scanning electron microscopy (SEM)-energy dispersive X-ray spectrometry (EDS) analyses. The microstructure of samples was studied by optical microscopy. Based on results of the analysis, a procedure for recycling PCBs is proposed. The emphasis was on the effects that can be achieved in the recycling process by extraction of some parts before the melting process. In addition, newly developed materials can be an adequate substitute for some of the dangerous and harmful materials, such as lead and arsenic are proposed, which is in accordance with the European Union (EU) Restriction of the use of certain hazardous substances (RoHS) directive as well as some alternative materials for use in the electronics industry instead of gold and gold alloys.

  7. Distinguishing Newly Born Strange Stars from Neutron Stars with g-Mode Oscillations

    International Nuclear Information System (INIS)

    Fu Weijie; Wei Haiqing; Liu Yuxin

    2008-01-01

    The gravity-mode (g-mode) eigenfrequencies of newly born strange quark stars (SQSs) and neutron stars (NSs) are studied. It is found that the eigenfrequencies in SQSs are much lower than those in NSs by almost 1 order of magnitude, since the components of a SQS are all extremely relativistic particles while nucleons in a NS are nonrelativistic. We therefore propose that newly born SQSs can be distinguished from the NSs by detecting the eigenfrequencies of the g-mode pulsations of supernovae cores through gravitational radiation by LIGO-class detectors

  8. Design report on SCDAP/RELAP5 model improvements - debris bed and molten pool behavior

    International Nuclear Information System (INIS)

    Allison, C.M.; Rempe, J.L.; Chavez, S.A.

    1994-11-01

    The SCDAP/RELAP5/MOD3 computer code is designed to describe the overall reactor coolant system thermal-hydraulic response, core damage progression, and in combination with VICTORIA, fission product release and transport during severe accidents. Improvements for existing debris bed and molten pool models in the SCDAP/RELAP5/MOD3.1 code are described in this report. Model improvements to address (a) debris bed formation, heating, and melting; (b) molten pool formation and growth; and (c) molten pool crust failure are discussed. Relevant data, existing models, proposed modeling changes, and the anticipated impact of the changes are discussed. Recommendations for the assessment of improved models are provided

  9. The risk of contracting infectious diseases in public swimming pools: a review

    Directory of Open Access Journals (Sweden)

    Zsófia Barna

    2012-12-01

    Full Text Available A review of pathogenic microorganisms presenting risk of infection in pool based artificial recreational water venues is extracted from the available scientific literature. The microorganisms are grouped both according to their way of spread and their survival and growth strategies and their characteristics relevant for the pool and spa based recreation are discussed. In order to put the proposed risks on a solid basis, among others a ten year excerpt of the waterborne disease statistics of the Centers for Disease Control and Prevention (CDC is used throughout the article.

  10. Design of hydrotherapy exercise pools.

    Science.gov (United States)

    Edlich, R F; Abidin, M R; Becker, D G; Pavlovich, L J; Dang, M T

    1988-01-01

    Several hydrotherapy pools have been designed specifically for a variety of aquatic exercise. Aqua-Ark positions the exerciser in the center of the pool for deep-water exercise. Aqua-Trex is a shallow underwater treadmill system for water walking or jogging. Swim-Ex generates an adjustable laminar flow that permits swimming without turning. Musculoskeletal conditioning can be accomplished in the above-ground Arjo shallow-water exercise pool. A hydrotherapy pool also can be custom designed for musculoskeletal conditioning in its shallow part and cardiovascular conditioning in a deeper portion of the pool. Regardless of the type of exercise, there is general agreement that the specific exercise conducted in water requires significantly more energy expenditure than when the same exercise is performed on land.

  11. Increasing the pool of deceased donor organs for kidney transplantation.

    Science.gov (United States)

    Schold, Jesse D; Segev, Dorry L

    2012-03-27

    Expanding the pool of available deceased donor kidneys is critical for improving the outcomes of prospective and current renal transplant candidates. A number of interventions have been proposed that may increase the pool of donors in the US. However, these interventions have variable levels of empirical evidence supporting their potential beneficial impact. Proposed interventions include the instigation of policies for presumed donor consent, the expansion of donor registration, increased quality oversight of transplant providers, financial incentives for donors, increased reimbursement for higher risk donors, alterations in organ allocation policies and distribution, and the selective use of donors with potential or known risk for disease transmission. Many of these interventions have contentious elements that may have delayed or impeded their implementation; however, these options should be considered in the context of the diminishing prognoses for prospective transplant patients, given the increasing scarcity of donor organs relative to the population need. In this Review, we outline the proposed interventions and briefly discuss salient issues that characterize the debates concerning their implementation and effectiveness. Ultimately, any intervention must be based on the best evidence available, with consideration of numerous stakeholders and in conjunction with a careful evaluation of long-term and potential unintended consequences.

  12. Swimming pool cleaner poisoning

    Science.gov (United States)

    Swimming pool cleaner poisoning occurs when someone swallows this type of cleaner, touches it, or breathes in ... The harmful substances in swimming pool cleaner are: Bromine ... copper Chlorine Soda ash Sodium bicarbonate Various mild acids

  13. Efficient pooling designs for library screening

    OpenAIRE

    Bruno, William J.; Knill, Emanuel; Balding, David J.; Bruce, D. C.; Doggett, N. A.; Sawhill, W. W.; Stallings, R. L.; Whittaker, Craig C.; Torney, David C.

    1994-01-01

    We describe efficient methods for screening clone libraries, based on pooling schemes which we call ``random $k$-sets designs''. In these designs, the pools in which any clone occurs are equally likely to be any possible selection of $k$ from the $v$ pools. The values of $k$ and $v$ can be chosen to optimize desirable properties. Random $k$-sets designs have substantial advantages over alternative pooling schemes: they are efficient, flexible, easy to specify, require fewer pools, and have er...

  14. Novel transmission pricing scheme based on point-to-point tariff and transaction pair matching for pool market

    International Nuclear Information System (INIS)

    Chen, Qixin; Xia, Qing; Kang, Chongqing

    2010-01-01

    Transmission pricing scheme is a key component in the infrastructure of power market, and pool is an indispensable pattern of market organization; meanwhile, pay-as-bid (PAB) serves as a main option to determine market prices in pool. In this paper, a novel transmission pricing scheme is proposed for pool power market based on PAB. The new scheme is developed by utilizing point-to-point (PTP) tariff and introducing an approach of transaction pair matching (TPM). The model and procedure of the new scheme are presented in detail. Apart from the advantages of existing transmission pricing schemes, such as ensuing open, fair and non-discriminatory access, proper recovery for investment as well as transparency, the new scheme provides economic signals to promote the maximum use of the existing transmission network, encourages appropriate bidding behaviors in pool, and helps to reduce the possibility of the enforcement of market power and the appearing of price spikes; thus improves market operation efficiency and trading effects. In order to testify the effectiveness of the proposed scheme, a case based on IEEE 30-bus system is studied. (author)

  15. Novel transmission pricing scheme based on point-to-point tariff and transaction pair matching for pool market

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Qixin; Xia, Qing; Kang, Chongqing [State Key Lab. of Power System, Dept. of Electrical Engineering, Tsinghua University, Beijing 100084 (China)

    2010-04-15

    Transmission pricing scheme is a key component in the infrastructure of power market, and pool is an indispensable pattern of market organization; meanwhile, pay-as-bid (PAB) serves as a main option to determine market prices in pool. In this paper, a novel transmission pricing scheme is proposed for pool power market based on PAB. The new scheme is developed by utilizing point-to-point (PTP) tariff and introducing an approach of transaction pair matching (TPM). The model and procedure of the new scheme are presented in detail. Apart from the advantages of existing transmission pricing schemes, such as ensuing open, fair and non-discriminatory access, proper recovery for investment as well as transparency, the new scheme provides economic signals to promote the maximum use of the existing transmission network, encourages appropriate bidding behaviors in pool, and helps to reduce the possibility of the enforcement of market power and the appearing of price spikes; thus improves market operation efficiency and trading effects. In order to testify the effectiveness of the proposed scheme, a case based on IEEE 30-bus system is studied. (author)

  16. 21 CFR 1250.89 - Swimming pools.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Swimming pools. 1250.89 Section 1250.89 Food and... SANITATION Sanitation Facilities and Conditions on Vessels § 1250.89 Swimming pools. (a) Fill and draw swimming pools shall not be installed or used. (b) Swimming pools of the recirculation type shall be...

  17. Mandatory high-risk pooling: an approach to reducing incentives for cream skimming.

    Science.gov (United States)

    van Barneveld, E M; van Vliet, R C; van de Ven, W P

    1996-01-01

    Risk-adjusted capitation payments (RACPs) to competing health insurers are an essential element of market-oriented health care reforms in The Netherlands. Crude RACPs are inadequate, especially because they encourage insurers to select against people expected to be unprofitable--a practice called cream skimming. However, implementing improved RACPs does not appear to be straightforward. This paper analyzes an approach that, given a system of crude RACPs, reduces insurers' incentives for cream skimming in the market for individual health insurance, while preserving incentives for efficiency and cost containment. Under the proposed system of Mandatory High-Risk Pooling (MHRP), each insurer would be allowed to periodically predetermine a small fraction of its members whose costs would be (partially) pooled. The pool would be financed with mandatory, flat-rate contributions. The results suggest that MHRP is a promising supplement to RACPs.

  18. Nucleotide Pool Depletion Induces G-Quadruplex-Dependent Perturbation of Gene Expression

    Directory of Open Access Journals (Sweden)

    Charikleia Papadopoulou

    2015-12-01

    Full Text Available Nucleotide pool imbalance has been proposed to drive genetic instability in cancer. Here, we show that slowing replication forks by depleting nucleotide pools with hydroxyurea (HU can also give rise to both transient and permanent epigenetic instability of a reporter locus, BU-1, in DT40 cells. HU induces stochastic formation of Bu-1low variants in dividing cells, which have lost the H3K4me3 present in untreated cells. This instability is potentiated by an intragenic G quadruplex, which also promotes local H2Ax phosphorylation and transient heterochromatinization. Genome-wide, gene expression changes induced by HU significantly overlap with those resulting from loss of the G4-helicases FANCJ, WRN, and BLM. Thus, the effects of global replication stress induced by nucleotide pool depletion can be focused by local replication impediments caused by G quadruplex formation to induce epigenetic instability and changes in gene expression, a mechanism that may contribute to selectable transcriptional changes in cancer.

  19. Modal analysis of pool door in water tank

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Soo; Jeong, Kyeong Hoon; Park, Chan Gook; Koo, In Soo [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    A pool door is installed at the chase of the pool gate by means of an overhead crane in the building of a research reactor. The principal function of the pool door, which is located between the reactor pool and service pool, is to separate the reactor pool from the service pool for the maintenance and/or the removal of the equipment either in the reactor pool or service pool. The pool door consists of stainless steel plates supported by structural steel frames and sealing components. The pool door is equipped with double inflatable gaskets. The configuration of the pool door is shown in Figure 1. The FEM analysis and theoretical calculation by the formula were performed to evaluate the natural frequency for the pool door in the water. The results from the two methods were compared.

  20. 75 FR 65263 - Virginia Graeme Baker Pool and Spa Safety Act; Public Accommodation; Withdrawal of Proposed Rule

    Science.gov (United States)

    2010-10-22

    ...'' or ``Act'') as ``an inn, hotel, motel, or other place of lodging, except for an establishment located... interpretive rule to interpret ``public accommodations facility'' in the VGB Act as ``an inn, hotel, motel, or... CONSUMER PRODUCT SAFETY COMMISSION 16 CFR Part 1450 Virginia Graeme Baker Pool and Spa Safety Act...

  1. 10 CFR 36.63 - Pool water purity.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Pool water purity. 36.63 Section 36.63 Energy NUCLEAR... § 36.63 Pool water purity. (a) Pool water purification system must be run sufficiently to maintain the conductivity of the pool water below 20 microsiemens per centimeter under normal circumstances. If pool water...

  2. Fuzzy pool balance: An algorithm to achieve a two dimensional balance in distribute storage systems

    International Nuclear Information System (INIS)

    Wu, Wenjing; Chen, Gang

    2014-01-01

    The limitation of scheduling modules and the gradual addition of disk pools in distributed storage systems often result in imbalances among their disk pools in terms of both disk usage and file count. This can cause various problems to the storage system such as single point of failure, low system throughput and imbalanced resource utilization and system loads. An algorithm named Fuzzy Pool Balance (FPB) is proposed here to solve this problem. The input of FPB is the current file distribution among disk pools and the output is a file migration plan indicating what files are to be migrated to which pools. FPB uses an array to classify the files by their sizes. The file classification array is dynamically calculated with a defined threshold named T max that defines the allowed pool disk usage deviations. File classification is the basis of file migration. FPB also defines the Immigration Pool (IP) and Emigration Pool (EP) according to the pool disk usage and File Quantity Ratio (FQR) that indicates the percentage of each category of files in each disk pool, so files with higher FQR in an EP will be migrated to IP(s) with a lower FQR of this file category. To verify this algorithm, we implemented FPB on an ATLAS Tier2 dCache production system. The results show that FPB can achieve a very good balance in both free space and file counts, and adjusting the threshold value T max and the correction factor to the average FQR can achieve a tradeoff between free space and file count.

  3. POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    King, V.

    2000-01-01

    The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of the Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous

  4. Mathematical model development of heat and mass exchange processes in the outdoor swimming pool

    Directory of Open Access Journals (Sweden)

    M. V. Shaptala

    2014-12-01

    Full Text Available Purpose. Currently exploitation of outdoor swimming pools is often not cost-effective and, despite of their relevance, such pools are closed in large quantities. At this time there is no the whole mathematical model which would allow assessing qualitatively the effect of energy-saving measures. The aim of this work is to develop a mathematical model of heat and mass exchange processes for calculating basic heat and mass losses that occur during its exploitation. Methodology. The method for determination of heat and mass loses based on the theory of similarity criteria equations is used. Findings. The main types of heat and mass losses of outdoor pool were analyzed. The most significant types were allocated and mathematically described. Namely: by evaporation of water from the surface of the pool, by natural and forced convection, by radiation to the environment, heat consumption for water heating. Originality. The mathematical model of heat and mass exchange process of the outdoor swimming pool was developed, which allows calculating the basic heat and mass loses that occur during its exploitation. Practical value. The method of determining heat and mass loses of outdoor swimming pool as a software system was developed and implemented. It is based on the mathematical model proposed by the authors. This method can be used for the conceptual design of energy-efficient structures of outdoor pools, to assess their use of energy-intensive and selecting the optimum energy-saving measures. A further step in research in this area is the experimental validation of the method of calculation of heat losses in outdoor swimming pools with its use as an example the pool of Dnipropetrovsk National University of Railway Transport named after Academician V. Lazaryan. The outdoor pool, with water heating- up from the boiler room of the university, is operated year-round.

  5. Research on Optimization of Pooling System and Its Application in Drug Supply Chain Based on Big Data Analysis.

    Science.gov (United States)

    Wu, DengFeng; Mao, Hongyi

    2017-01-01

    Reform of drug procurement is being extensively implemented and expanded in China, especially in today's big data environment. However, the pattern of supply mode innovation lags behind procurement improvement. Problems in financial strain and supply break frequently occur, which affect the stability of drug supply. Drug Pooling System is proposed and applied in a few pilot cities to resolve these problems. From the perspective of supply chain, this study analyzes the process of setting important parameters and sets out the tasks of involved parties in a pooling system according to the issues identified in the pilot run. The approach is based on big data analysis and simulation using system dynamic theory and modeling of Vensim software to optimize system performance. This study proposes a theoretical framework to resolve problems and attempts to provide a valuable reference for future application of pooling systems.

  6. Self-formed waterfall plunge pools in homogeneous rock

    Science.gov (United States)

    Scheingross, Joel S.; Lo, Daniel Y.; Lamb, Michael P.

    2017-01-01

    Waterfalls are ubiquitous, and their upstream propagation can set the pace of landscape evolution, yet no experimental studies have examined waterfall plunge pool erosion in homogeneous rock. We performed laboratory experiments, using synthetic foam as a bedrock simulant, to produce self-formed waterfall plunge pools via particle impact abrasion. Plunge pool vertical incision exceeded lateral erosion by approximately tenfold until pools deepened to the point that the supplied sediment could not be evacuated and deposition armored the pool bedrock floor. Lateral erosion of plunge pool sidewalls continued after sediment deposition, but primarily at the downstream pool wall, which might lead to undermining of the plunge pool lip, sediment evacuation, and continued vertical pool floor incision in natural streams. Undercutting of the upstream pool wall was absent, and our results suggest that vertical drilling of successive plunge pools is a more efficient waterfall retreat mechanism than the classic model of headwall undercutting and collapse in homogeneous rock.

  7. Patent pools: Intellectual property rights and competition.

    NARCIS (Netherlands)

    Rodriguez, V.F.

    2010-01-01

    Patent pools do not correct all problems associated with patent thickets. In this respect, patent pools might not stop the outsider problem from striking pools. Moreover, patent pools can be expensive to negotiate, can exclude patent holders with smaller numbers of patents or enable a group of major

  8. Subclassification of newly diagnosed glioblastomas through an immunohistochemical approach.

    Directory of Open Access Journals (Sweden)

    Siobhan Conroy

    Full Text Available Molecular signatures in Glioblastoma (GBM have been described that correlate with clinical outcome and response to therapy. The Proneural (PN and Mesenchymal (MES signatures have been identified most consistently, but others including Classical (CLAS have also been reported. The molecular signatures have been detected by array techniques at RNA and DNA level, but these methods are costly and cannot take into account individual contributions of different cells within a tumor. Therefore, the aim of this study was to investigate whether subclasses of newly diagnosed GBMs could be assessed and assigned by application of standard pathology laboratory procedures. 123 newly diagnosed GBMs were analyzed for the tumor cell expression of 23 pre-identified proteins and EGFR amplification, together allowing for the subclassification of 65% of the tumors. Immunohistochemistry (IHC-based profiling was found to be analogous to transcription-based profiling using a 9-gene transcriptional signature for PN and MES subclasses. Based on these data a novel, minimal IHC-based scheme for subclass assignment for GBMs is proposed. Positive staining for IDH1R132H can be used for PN subclass assignment, high EGFR expression for the CLAS subtype and a combined high expression of PTEN, VIM and/or YKL40 for the MES subclass. The application of the proposed scheme was evaluated in an independent tumor set, which resulted in similar subclass assignment rates as those observed in the training set. The IHC-based subclassification scheme proposed in this study therefore could provide very useful in future studies for stratification of individual patient samples.

  9. Biosynthesis of N-glycolyneuraminic acid. The primary site of hydroxylation of N-acetylneuraminic acid is the cytosolic sugar nucleotide pool

    Energy Technology Data Exchange (ETDEWEB)

    Muchmore, E.A.; Milewski, M.; Varki, A.; Diaz, S. (San Diego Veterans Administration Medical Center, CA (USA))

    1989-12-05

    N-Glycolylneuraminic acid (Neu5Gc) is an oncofetal antigen in humans and is developmentally regulated in rodents. We have explored the biology of N-acetylneuraminic acid hydroxylase, the enzyme responsible for conversion of the parent sialic acid, N-acetylneuraminic acid (Neu5Ac) to Neu5Gc. We show that the major sialic acid in all compartments of murine myeloma cell lines is Neu5Gc. Pulse-chase analysis in these cells with the sialic acid precursor (6-3H)N-acetylmannosamine demonstrates that most of the newly synthesized Neu5Gc appears initially in the cytosolic low-molecular weight pool bound to CMP. The percentage of Neu5Gc on membrane-bound sialic acids closely parallels that in the CMP-bound pool at various times of chase, whereas that in the free sialic acid pool is very low initially, and rises only later during the chase. This implies that conversion from Neu5Ac to Neu5Gc occurs primarily while Neu5Ac is in its sugar nucleotide form. In support of this, the hydroxylase enzyme from a variety of tissues and cells converted CMP-Neu5Ac to CMP-Neu5Gc, but showed no activity towards free or alpha-glycosidically bound Neu5Ac. Furthermore, the majority of the enzyme activity is found in the cytosol. Studies with isolated intact Golgi vesicles indicate that CMP-Neu5Gc can be transported and utilized for transfer of Neu5Gc to glycoconjugates. The general properties of the enzyme have also been investigated. The Km for CMP-Neu5Ac is in the range of 0.6-2.5 microM. No activity can be detected against the beta-methylglycoside of Neu5Ac. On the other hand, inhibition studies suggest that the enzyme recognizes both the 5'-phosphate group and the pyrimidine base of the substrate. Taken together, the data allow us to propose pathways for the biosynthesis and reutilization of Neu5Gc.

  10. Analysis of sodium pool fire in SFEF for assessing the limiting pool fire

    International Nuclear Information System (INIS)

    Mangarjuna Rao, P.; Ramesh, S.S.; Nashine, B.K.; Kasinathan, N.; Chellapandi, P.

    2011-01-01

    Accidental sodium leaks and resultant sodium fires in Liquid Metal Fast Breeder Reactor (LMFBR) systems can create a threat to the safe operation of the plant. To avoid this defence-in depth approach is implemented from the design stage of reactor itself. Rapid detection of sodium leak and fast dumping of the sodium into the storage tank of a defective circuit, leak collection trays, adequate lining of load bearing structural concrete and extinguishment of the sodium fire are the important defensive measures in the design, construction and operation of a LMFBR for protection against sodium leaks and their resultant fires. Evaluation of sodium leak events and their consequences by conducting large scale engineering experiments is very essential for effective implementation of the above protection measures for sodium fire safety. For this purpose a Sodium Fire Experimental Facility (SFEF) is constructed at SED, IGCAR. SFEF is having an experimental hall of size 9 m x 6 m x 10 m with 540 m 3 volume and its design pressure is 50 kPa. It is a concrete structure and provided with SS 304 liner, which is fixed to the inside surfaces of walls, ceiling and floor. A leak tight door of size (1.8 m x 2.0 m) is provided to the experimental hall and the facility is provided with a sodium equipment hall and a control room. Experimental evaluation of sodium pool fire consequences is an important activity in the LMFBR sodium fire safety related studies. An experimental program has been planned for different types of sodium fire studies in SFEF. A prior to that numerical analysis have been carried out for enclosed sodium pool fires using SOFIRE-II sodium pool fire code for SFEF experimental hall configuration to evaluate the limiting pool fire. This paper brings out results of the analysis carried out for this purpose. Limiting pool fire of SFEF depends on the exposed surface area of the pool, amount of sodium in the pool, oxygen concentration and initial sodium temperature. Limiting

  11. Conjugated heat transfer of natural convection in pool with internal heat sources and convection in the tube

    International Nuclear Information System (INIS)

    Li Longjian; Liu Hongtao; Cui Wenzhi

    2007-01-01

    The conjugated heat transfer of natural convection in pool with internal heat source and the forced convection in the tube was analyzed, and the corresponding three-dimensional physical and mathematical model was proposed. A control volume based finite element method was employed to solve numerically the problem. The computations were performed for different internal heat source intensity of the pool and the different flow velocity in the tube. The computed heat transfer coefficients on the inner and outer wall showed well consistency of those calculated with the empirical correlations. Compared with the measured total heat transfer coefficients between the fluids in and out of the tube, the computed ones showed also the well consistency, which implied that the numerical model proposed in this paper was reliable. The research results revealed that the total heat transfer coefficients between the fluids were strongly affected by the internal heat source intensity of the pool liquid and the flow velocity in the tube. (authors)

  12. 1968 Listing of Swimming Pool Equipment.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  13. A strategy for optimizing item-pool management

    NARCIS (Netherlands)

    Ariel, A.; van der Linden, Willem J.; Veldkamp, Bernard P.

    2006-01-01

    Item-pool management requires a balancing act between the input of new items into the pool and the output of tests assembled from it. A strategy for optimizing item-pool management is presented that is based on the idea of a periodic update of an optimal blueprint for the item pool to tune item

  14. Swimming Pools and Molluscum Contagiosum

    Science.gov (United States)

    ... Travelers’ Health: Smallpox & Other Orthopoxvirus-Associated Infections Poxvirus Swimming Pools Recommend on Facebook Tweet Share Compartir The ... often ask if molluscum virus can spread in swimming pools. There is also concern that it can ...

  15. Pooling and correlated neural activity

    Directory of Open Access Journals (Sweden)

    Robert Rosenbaum

    2010-04-01

    Full Text Available Correlations between spike trains can strongly modulate neuronal activity and affect the ability of neurons to encode information. Neurons integrate inputs from thousands of afferents. Similarly, a number of experimental techniques are designed to record pooled cell activity. We review and generalize a number of previous results that show how correlations between cells in a population can be amplified and distorted in signals that reflect their collective activity. The structure of the underlying neuronal response can significantly impact correlations between such pooled signals. Therefore care needs to be taken when interpreting pooled recordings, or modeling networks of cells that receive inputs from large presynaptic populations. We also show that the frequently observed runaway synchrony in feedforward chains is primarily due to the pooling of correlated inputs.

  16. In-service inspection of pool type research reactors

    International Nuclear Information System (INIS)

    Rajamani, K.

    2002-01-01

    In the case of Apsara Reactor, it has been proposed to carry out major modifications in the near future. It is planned to modify the core suitably with a heavy water reflector tank to demonstrate the Multiple Purpose Research Reactor concept. The core structure will be a stationary one and will be located at the 'B' position of the pool. The modified reactor will be operated at 1 MW power level. Suitable methodologies are evolved for carrying out a planned ISI for this modified reactor

  17. Method of measuring a liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.

    1991-03-19

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.

  18. Design and Construction of Pool Door for Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door.

  19. Design and Construction of Pool Door for Research Reactor

    International Nuclear Information System (INIS)

    Jung, Kwangsub; Lee, Sangjin; Choi, Jinbok; Oh, Jinho; Lee, Jongmin

    2016-01-01

    The pool door is a structure to isolate the reactor pool from the service pool for maintenance. The pool door is installed before the reactor pool is drained. The pool door consists of structural component and sealing component. The main structures of the pool door are stainless steel plates and side frames. The plates and frames are assembled by welded joints. Lug is welded at the top of the plate. The pool door is submerged in the pool water when it is used. Materials of the pool door should be resistive to corrosion and radiation. Stainless steel is used in structural components and air nozzle assemblies. Features of design and construction of the pool door for the research reactor are introduced. The pool door is designed to isolate the reactor pool for maintenance. Structural analysis is performed to evaluate the structural integrity during earthquake. Tests and inspections are also carried out during construction to identify the safety and function of the pool door

  20. Structural integrity assessment of HANARO pool cover

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo

    2001-11-01

    This report is for the seismic analysis and the structural integrity evaluation of HANARO Pool Cover in accordances with the requirement of the Technical Specification for Seismic Analysis of HANARO Pool Cover. For performing the seismic analysis and evaluating the structural integrity for HANARO Pool Cover, the finite element analysis model using ANSYS 5.7 was developed and the dynamic characteristics were analyzed. The seismic response spectrum analyses of HANARO Pool Cover under the design floor response spectrum loads of OBE and SSE were performed. The analysis results show that the stress values in HANARO Pool Cover for the seismic loads are within the ASME Code limits. It is also confirmed that the fatigue usage factor is less than 1.0. Therefore any damage on structural integrity is not expected when an HANARO Pool Cover is installed in the upper part of the reactor pool

  1. Clinical Prediction Model for Time in Therapeutic Range While on Warfarin in Newly Diagnosed Atrial Fibrillation.

    Science.gov (United States)

    Williams, Brent A; Evans, Michael A; Honushefsky, Ashley M; Berger, Peter B

    2017-10-12

    Though warfarin has historically been the primary oral anticoagulant for stroke prevention in newly diagnosed atrial fibrillation (AF), several new direct oral anticoagulants may be preferred when anticoagulation control with warfarin is expected to be poor. This study developed a prediction model for time in therapeutic range (TTR) among newly diagnosed AF patients on newly initiated warfarin as a tool to assist decision making between warfarin and direct oral anticoagulants. This electronic medical record-based, retrospective study included newly diagnosed, nonvalvular AF patients with no recent warfarin exposure receiving primary care services through a large healthcare system in rural Pennsylvania. TTR was estimated as the percentage of time international normalized ratio measurements were between 2.0 and 3.0 during the first year following warfarin initiation. Candidate predictors of TTR were chosen from data elements collected during usual clinical care. A TTR prediction model was developed and temporally validated and its predictive performance was compared with the SAMe-TT 2 R 2 score (sex, age, medical history, treatment, tobacco, race) using R 2 and c-statistics. A total of 7877 newly diagnosed AF patients met study inclusion criteria. Median (interquartile range) TTR within the first year of starting warfarin was 51% (32, 67). Of 85 candidate predictors evaluated, 15 were included in the final validated model with an R 2 of 15.4%. The proposed model showed better predictive performance than the SAMe-TT 2 R 2 score ( R 2 =3.0%). The proposed prediction model may assist decision making on the proper mode of oral anticoagulant among newly diagnosed AF patients. However, predicting TTR on warfarin remains challenging. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  2. Life cycle environmental implications of residential swimming pools.

    Science.gov (United States)

    Forrest, Nigel; Williams, Eric

    2010-07-15

    Ownership of private swimming pools in the U.S. grew 2 to 4% per annum from 1997 to 2007. The environmental implications of pool ownership are analyzed by hybrid life cycle assessment (LCA) for nine U.S. cities. An operational model is constructed estimating consumption of chemicals, water, and energy for a typical residential pool. The model incorporates geographical climatic variations and upstream water and energy use from electricity and water supply networks. Results vary considerably by city: a factor of 5-6 for both water and energy use. Water use is driven by aridness and length of the swimming season, while energy use is mainly driven by length of the swimming season. Water and energy impacts of pools are significant, particularly in arid climates. In Phoenix for example pools account for 22% and 13% of a household's electricity and water use, respectively. Measures to reduce water and energy use in pools such as optimizing the pump schedule and covering the pool in winter can realize greater savings than many common household efficiency improvements. Private versus community pools are also compared. Community pools in Phoenix use 60% less swimming pool water and energy per household than subdivisions without community pools.

  3. Heat and mass transfer in a liquid pool with wall ablation and composition effects

    International Nuclear Information System (INIS)

    Pham, Q.T.

    2013-01-01

    This work deals with the thermal-hydraulics of a melt pool coupled with the physical chemistry for the purpose of describing the behaviour of mixtures of materials (non-eutectic). Evolution of transient temperature in a liquid melt pool heated by volumetric power dissipation has been described with solidification on the cooled wall. The model has been developed and is validated for the experimental results given by LIVE experiment, performed at Karlsruhe Institute of Technology (KIT) in Germany. Under the conditions of these tests, it is shown that the interface temperature follows the liquidus temperature (corresponding to the composition of the liquid bath) during the whole transient. Assumption of interface temperature as liquidus temperature allows recalculating the evolution of the maximum melt temperature as well as the local crust thickness. Furthermore, we propose a model for describing the interaction between a non-eutectic liquid melt pool (subjected to volumetric power dissipation) and an ablated wall whose melting point is below the liquidus temperature of the melt. The model predictions are compared with results of ARTEMIS 2D tests. A new formulation of the interface temperature between the liquid melt and the solid wall (below liquidus temperature) has been proposed. (author) [fr

  4. Occurrence and simulation of trihalomethanes in swimming pool water: A simple prediction method based on DOC and mass balance.

    Science.gov (United States)

    Peng, Di; Saravia, Florencia; Abbt-Braun, Gudrun; Horn, Harald

    2016-01-01

    Trihalomethanes (THM) are the most typical disinfection by-products (DBPs) found in public swimming pool water. DBPs are produced when organic and inorganic matter in water reacts with chemical disinfectants. The irregular contribution of substances from pool visitors and long contact time with disinfectant make the forecast of THM in pool water a challenge. In this work occurrence of THM in a public indoor swimming pool was investigated and correlated with the dissolved organic carbon (DOC). Daily sampling of pool water for 26 days showed a positive correlation between DOC and THM with a time delay of about two days, while THM and DOC didn't directly correlate with the number of visitors. Based on the results and mass-balance in the pool water, a simple simulation model for estimating THM concentration in indoor swimming pool water was proposed. Formation of THM from DOC, volatilization into air and elimination by pool water treatment were included in the simulation. Formation ratio of THM gained from laboratory analysis using native pool water and information from field study in an indoor swimming pool reduced the uncertainty of the simulation. The simulation was validated by measurements in the swimming pool for 50 days. The simulated results were in good compliance with measured results. This work provides a useful and simple method for predicting THM concentration and its accumulation trend for long term in indoor swimming pool water. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Practicing on Newly Dead

    Directory of Open Access Journals (Sweden)

    Jewel Abraham

    2015-07-01

    Full Text Available A newly dead cadaver simulation is practiced on the physical remains of the dead before the onset of rigor mortis. This technique has potential benefits for providing real-life in-situ experience for novice providers in health care practices. Evolving ethical views in health care brings into question some of the ethical aspects associated with newly dead cadaver simulation in terms of justification for practice, autonomy, consent, and the need of disclosure. A clear statement of policies and procedures on newly dead cadaver simulation has yet to be implemented. Although there are benefits and disadvantages to an in-situ cadaver simulation, such practices should not be carried out in secrecy as there is no compelling evidence that suggests such training as imperative. Secrecy in these practices is a violation of honor code of nursing ethics. As health care providers, practitioners are obliged to be ethically honest and trustworthy to their patients. The author explores the ethical aspects of using newly dead cadaver simulation in training novice nursing providers to gain competency in various lifesaving skills, which otherwise cannot be practiced on a living individual. The author explores multiple views on cadaver simulation in relation to ethical theories and practices such as consent and disclosure to family.

  6. Structure for nuclear fuel storage pools

    International Nuclear Information System (INIS)

    Ebata, Sakae; Nichiei, Shinji.

    1979-01-01

    Purpose: To enable leak detection in nuclear fuel storage pools, as well as prevent external leakages while keeping the strength of the constructional structures. Constitution: Protection plates are provided around pool linear plates and a leak reception is provided to the bottom. Leakages are detected by leak detecting pipeways and the external leakages are prevented by collecting them in a detection area provided in the intermediate layer. Since ferro-reinforcements at the bottom wall of the pool are disconnected by the protection plate making it impossible to form the constructional body, body hunches are provided to the bottom wall of the pool for processing the ferro-reinforcements. (Yoshino, Y.)

  7. Development and validation of effective models for simulation of stratification and mixing phenomena in a pool of water

    Energy Technology Data Exchange (ETDEWEB)

    Li, H.; Kudinov, P.; Villanueva, W. (Royal Institute of Technology (KTH). Div. of Nuclear Power Safety (Sweden))

    2011-06-15

    This work pertains to the research program on Containment Thermal-Hydraulics at KTH. The objective is to evaluate and improve performance of methods, which are used to analyze thermal-hydraulics of steam suppression pools in a BWR plant under different abnormal transient and accident conditions. The pressure suppression pool was designed to have the capability as a heat sink to cool and condense steam released from the core vessel and/or main steam line during loss of coolant accident (LOCA) or opening of safety relief valve in normal operation of BWRs. For the case of small flow rates of steam influx, thermal stratification could develop on the part above the blowdown pipe exit and significantly impede the pool's pressure suppression capacity. Once steam flow rate increases significantly, momentum introduced by the steam injection and/or periodic expansion and collapse of large steam bubbles due to direct contact condensation can destroy stratified layers and lead to mixing of the pool water. We use CFD-like model of the general purpose thermal-hydraulic code GOTHIC for addressing the issues of stratification and mixing in the pool. In the previous works we have demonstrated that accurate and computationally efficient prediction of the pool thermal-hydraulics in the scenarios with transition between thermal stratification and mixing, presents a computational challenge. The reason is that direct contact condensation phenomena, which drive oscillatory motion of the water in the blowdown pipes, are difficult to simulate with original GOTHIC models because of appearance of artificial oscillations due to numerical disturbances. To resolve this problem we propose to model the effect of steam injection on the mixing and stratification with the Effective Heat Source (EHS) model and the Effective Momentum Source (EMS) model. We use POOLEX/PPOOLEX experiment (Lappeenranta University of Technology in Finland), in order to (a) quantify errors due to GOTHIC

  8. Development and validation of effective models for simulation of stratification and mixing phenomena in a pool of water

    International Nuclear Information System (INIS)

    Li, H.; Kudinov, P.; Villanueva, W.

    2011-06-01

    This work pertains to the research program on Containment Thermal-Hydraulics at KTH. The objective is to evaluate and improve performance of methods, which are used to analyze thermal-hydraulics of steam suppression pools in a BWR plant under different abnormal transient and accident conditions. The pressure suppression pool was designed to have the capability as a heat sink to cool and condense steam released from the core vessel and/or main steam line during loss of coolant accident (LOCA) or opening of safety relief valve in normal operation of BWRs. For the case of small flow rates of steam influx, thermal stratification could develop on the part above the blowdown pipe exit and significantly impede the pool's pressure suppression capacity. Once steam flow rate increases significantly, momentum introduced by the steam injection and/or periodic expansion and collapse of large steam bubbles due to direct contact condensation can destroy stratified layers and lead to mixing of the pool water. We use CFD-like model of the general purpose thermal-hydraulic code GOTHIC for addressing the issues of stratification and mixing in the pool. In the previous works we have demonstrated that accurate and computationally efficient prediction of the pool thermal-hydraulics in the scenarios with transition between thermal stratification and mixing, presents a computational challenge. The reason is that direct contact condensation phenomena, which drive oscillatory motion of the water in the blowdown pipes, are difficult to simulate with original GOTHIC models because of appearance of artificial oscillations due to numerical disturbances. To resolve this problem we propose to model the effect of steam injection on the mixing and stratification with the Effective Heat Source (EHS) model and the Effective Momentum Source (EMS) model. We use POOLEX/PPOOLEX experiment (Lappeenranta University of Technology in Finland), in order to (a) quantify errors due to GOTHIC's physical models

  9. The Study of Pallet Pooling Information Platform Based on Cloud Computing

    Directory of Open Access Journals (Sweden)

    Jia-bin Li

    2018-01-01

    Full Text Available Effective implementation of pallet pooling system needs a strong information platform to support. Through the analysis of existing pallet pooling information platform (PPIP, the paper pointed out that the existing studies of PPIP are mainly based on traditional IT infrastructures and technologies which have software, hardware, resource utilization, and process restrictions. Because of the advantages of cloud computing technology like strong computing power, high flexibility, and low cost which meet the requirements of the PPIP well, this paper gave a PPIP architecture of two parts based on cloud computing: the users client and the cloud services. The cloud services include three layers, which are IaaS, PaaS, and SaaS. The method of how to deploy PPIP based on cloud computing is proposed finally.

  10. Spent fuel pool cleanup and stabilization

    International Nuclear Information System (INIS)

    Miller, R.L.

    1987-06-01

    Each of the plutonium production reactors at Hanford had a large water-filled spent fuel pool to provide interim storage of irradiated fuel while awaiting shipment to the separation facilities. After cessation of reactor operations the fuel was removed from the pools and the water levels were drawn down to a 5- to 10-foot depth. The pools were maintained with the water to provide shielding and radiological control. What appeared to be a straightforward project to process the water, remove the sediments from the basin, and stabilize the contamination on the floors and walls became a very complex and time consuming operation. The sediment characteristics varied from pool to pool, the ion exchange system required modification, areas of hard-pack sediments were discovered on the floors, special arrangements to handle and package high dose rate items for shipment were required, and contract problems ensued with the subcontractor. The original schedule to complete the project from preliminary engineering to final stabilization of the pools was 15 months. The actual time required was about 25 months. The original cost estimate to perform the work was $2,651,000. The actual cost of the project was $5,120,000, which included $150,000 for payment of claims to the subcontractor. This paper summarizes the experiences associated with the cleanup and radiological stabilization of the 100-B, -C, -D, and -DR spent fuel pools, and discusses a number of lessons learned items

  11. Evaporation-preventive device for nuclear reactor pool water

    International Nuclear Information System (INIS)

    Kurusu, Yoshihisa; Akabori, Shiro.

    1986-01-01

    Purpose: To prevent pool water from evaporating by a great amount in a reactor pool such as a spent fuel storing pool. Constitution: Air discharge and in-take ports are disposed just above the surface of the pool water and charge and discharge of airs are forcively carried out to form air curtains above the pool water. Water vapor evaporated from the surface of the pool water does not diffuse above the air curtains due to the air stream of the curtains, but is intaken into the intake port and then condensated into water by a steam condensator and re-supplied to the pool. Since diffusion of water vapor and radioactive materials are suppressed above the air curtains, the working circumstance in the pool chamber can be maintained desirably thereby keeping the radioactivity dose in the atmosphere. Further, incorporation of dusts from above into the pool can also be prevented by the air curtains to provide an effect for the prevention of radioactive contamination. Further, since covers are not used, visual observation can be insured. (Kawakami, Y.)

  12. Ripples in a superconducting tidal pool

    CERN Document Server

    Hudson, E

    2003-01-01

    The behaviour of electrons in a metal is often compared to that of water in a pool. An empty pool is like a material that has all of its electrons removed. As electrons are 'poured' into the metal, they first occupy the lowest energies available - the bottom of the pool - and eventually fill up to the Fermi energy, the top of the pool. At this point we no longer discuss electrons but quasiparticles. These are electrons that have modified properties due to their interactions within the material. Waves in a pool can be excited, and their properties will depend on the depth of the water. Similarly in a metal, quasiparticles behave like waves that have a material-dependent dispersion relation between their energy and their wavevector, which specifies their direction and wavelength. This simple analogy also hints at an indirect method of measuring the dispersion relation of a metal, and hence the myriad of properties that depend on it. (U.K.)

  13. Biosynthesis of N-glycolyneuraminic acid. The primary site of hydroxylation of N-acetylneuraminic acid is the cytosolic sugar nucleotide pool.

    Science.gov (United States)

    Muchmore, E A; Milewski, M; Varki, A; Diaz, S

    1989-12-05

    N-Glycolylneuraminic acid (Neu5Gc) is an oncofetal antigen in humans and is developmentally regulated in rodents. We have explored the biology of N-acetylneuraminic acid hydroxylase, the enzyme responsible for conversion of the parent sialic acid, N-acetylneuraminic acid (Neu5Ac) to Neu5Gc. We show that the major sialic acid in all compartments of murine myeloma cell lines is Neu5Gc. Pulse-chase analysis in these cells with the sialic acid precursor [6-3H]N-acetylmannosamine demonstrates that most of the newly synthesized Neu5Gc appears initially in the cytosolic low-molecular weight pool bound to CMP. The percentage of Neu5Gc on membrane-bound sialic acids closely parallels that in the CMP-bound pool at various times of chase, whereas that in the free sialic acid pool is very low initially, and rises only later during the chase. This implies that conversion from Neu5Ac to Neu5Gc occurs primarily while Neu5Ac is in its sugar nucleotide form. In support of this, the hydroxylase enzyme from a variety of tissues and cells converted CMP-Neu5Ac to CMP-Neu5Gc, but showed no activity towards free or alpha-glycosidically bound Neu5Ac. Furthermore, the majority of the enzyme activity is found in the cytosol. Studies with isolated intact Golgi vesicles indicate that CMP-Neu5Gc can be transported and utilized for transfer of Neu5Gc to glycoconjugates. The general properties of the enzyme have also been investigated. The Km for CMP-Neu5Ac is in the range of 0.6-2.5 microM. No activity can be detected against the beta-methylglycoside of Neu5Ac. On the other hand, inhibition studies suggest that the enzyme recognizes both the 5'-phosphate group and the pyrimidine base of the substrate. Taken together, the data allow us to propose pathways for the biosynthesis and reutilization of Neu5Gc, with initial conversion from Neu5Ac occurring primarily at the level of the sugar nucleotide. Subsequent release and reutilization of Neu5Gc could then account for the higher steady-state level

  14. Swimming pools as heat sinks for air conditioners: Model design and experimental validation for natural thermal behavior of the pool

    Energy Technology Data Exchange (ETDEWEB)

    Woolley, Jonathan; Harrington, Curtis; Modera, Mark [University of California Davis, Western Cooling Efficiency Center, 1450 Drew Avenue, Suite 100, Davis, CA 95618 (United States)

    2011-01-15

    Swimming pools as thermal sinks for air conditioners could save approximately 40% on peak cooling power and 30% of overall cooling energy, compared to standard residential air conditioning. Heat dissipation from pools in semi-arid climates with large diurnal temperature shifts is such that pool heating and space cooling may occur concurrently; in which case heat rejected from cooling equipment could directly displace pool heating energy, while also improving space cooling efficiency. The performance of such a system relies on the natural temperature regulation of swimming pools governed by evaporative and convective heat exchange with the air, radiative heat exchange with the sky, and conductive heat exchange with the ground. This paper describes and validates a model that uses meteorological data to accurately predict the hourly temperature of a swimming pool to within 1.1 C maximum error over the period of observation. A thorough review of literature guided our choice of the most appropriate set of equations to describe the natural mass and energy exchange between a swimming pool and the environment. Monitoring of a pool in Davis, CA, was used to confirm the resulting simulations. Comparison of predicted and observed pool temperature for all hours over a 56 day experimental period shows an R-squared relatedness of 0.967. (author)

  15. Payroll System in Swimming Pool Tasa Using Visual Basic .Net 2003

    OpenAIRE

    Parcel Natalnael Hutabarat; Rahayu Noveandini, SKom, MM

    2008-01-01

    With the proposed payroll system built on this design, it can replace the manual system to process payroll, and expect to be able to overcome the weaknesses that have been faced by TASA and the swimming pool is also a way to simplify payroll activities TASA which during the many weaknesses . With the system that uses computer services is expected to help TASA employee wage freeze.

  16. Cold pool organization and the merging of convective updrafts in a Large Eddy Simulation

    Science.gov (United States)

    Glenn, I. B.; Krueger, S. K.

    2016-12-01

    Cold pool organization is a process that accelerates the transition from shallow to deep cumulus convection, and leads to higher deep convective cloud top heights. The mechanism by which cold pool organization enhances convection remains not well understood, but the basic idea is that since precipitation evaporation and a low equivalent potential temperature in the mid-troposphere lead to strong cold pools, the net cold pool effect can be accounted for in a cumulus parameterization as a relationship involving those factors. Understanding the actual physical mechanism at work will help quantify the strength of the relationship between cold pools and enhanced deep convection. One proposed mechanism of enhancement is that cold pool organization leads to reduced distances between updrafts, creating a local environment more conducive to convection as updrafts entrain parcels of air recently detrained by their neighbors. We take this hypothesis one step further and propose that convective updrafts actually merge, not just exchange recently processed air. Because entrainment and detrainment around an updraft draws nearby air in or pushes it out, respectively, they act like dynamic flow sources and sinks, drawing each other in or pushing each other away. The acceleration is proportional to the inverse square of the distance between two updrafts, so a small reduction in distance can make a big difference in the rate of merging. We have shown in previous research how merging can be seen as collisions between different updraft air parcels using Lagrangian Parcel Trajectories (LPTs) released in a Large Eddy Simulation (LES) during a period with organized deep convection. Now we use a Eulerian frame of reference to examine the updraft merging process during the transition from shallow to organized deep convection. We use a case based on the Large-Scale Biosphere-Atmosphere Experiment in Amazonia (LBA) for our LES. We directly measure the rate of entrainment and the properties

  17. Effect of turbulent natural convection on sodium pool combustion in the steam generator building of a fast breeder reactor

    International Nuclear Information System (INIS)

    Karthikeyan, S.; Sundararajan, T.; Shet, U.S.P.; Selvaraj, P.

    2009-01-01

    A computational model is proposed to simulate sodium pool combustion considering the effect of turbulent natural convection in a vented enclosure of the steam generator building (SGB) of a fast breeder reactor. The model is validated by comparing the simulated results with the experimental results available in literature for sodium pool combustion in a CSTF vessel. After validation, the effects of vents and the location of the pool on the burning rate of sodium and the associated heat transfer to the walls are studied in an enclosure comparable in size to one floor of the steam generator building. In the presence of ventilation, the burning rate of sodium increases, but the total heat transferred to the walls of the enclosure is reduced. It is also found that the burning rate of sodium pool and the heat transfer to the walls of the enclosures vary significantly with the location of sodium pool.

  18. Newly graduated nurses' use of knowledge sources

    DEFF Research Database (Denmark)

    Voldbjerg, Siri Lygum; Grønkjaer, Mette; Sørensen, Erik Elgaard

    2016-01-01

    AIM: To advance evidence on newly graduated nurses' use of knowledge sources. BACKGROUND: Clinical decisions need to be evidence-based and understanding the knowledge sources that newly graduated nurses use will inform both education and practice. Qualitative studies on newly graduated nurses' use...... underscoring progression in knowledge use and perception of competence and confidence among newly graduated nurses. CONCLUSION: The transition phase, feeling of confidence and ability to use critical thinking and reflection, has a great impact on knowledge sources incorporated in clinical decisions....... The synthesis accentuates that for use of newly graduated nurses' qualifications and skills in evidence-based practice, clinical practice needs to provide a supportive environment which nurtures critical thinking and questions and articulates use of multiple knowledge sources....

  19. Decontamination of outdoor school swimming pools in Fukushima

    International Nuclear Information System (INIS)

    Saegusa, Jun

    2013-01-01

    After the Fukushima Daiichi NPP accident following the Great East Japan Earthquake, many school swimming pools in Fukushima have suspended water discharge, due to concerns that pool water which contains radioactive fallout is discharged into a river or waterway for agricultural use. The Japan Atomic Energy Agency conducted researches and examinations on the existing absorbent method and the flocculation method as ways for decontaminating pool water. By reviewing and improving these methods through decontamination demonstrations at eight pools in Fukushima, a practical decontamination method for outdoor pools has been established. This report summarizes the methods and results of the decontamination demonstrations carried out at the schools. Also, the surface density of fallout estimated at one of the pools is also presented and discussed in connection with the overall collection ratio of radiocesium at the pool. (author)

  20. 48 CFR 873.114 - Best value pool.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Best value pool. 873.114... SUPPLEMENTARY REGULATIONS SIMPLIFIED ACQUISITION PROCEDURES FOR HEALTH-CARE RESOURCES 873.114 Best value pool... solicitation. These vendors constitute the best value pool. This determination is within the sole discretion of...

  1. Solid particle effects on heat transfer in a multi-layered molten pool with gas injection

    International Nuclear Information System (INIS)

    Bilbao y Leon, Rosa Marina; Corradini, Michael L.

    2006-01-01

    In the very unlikely event of a severe reactor accident involving core melt and pressure vessel failure, it is important to identify the circumstances that would allow the molten core material to cool down and resolidify, bringing core debris to a stable coolable state. To achieve this, it has been proposed to flood the cavity with water from above forming a layered structure where upward heat loss from the molten pool to the water will cause the core material to quench and solidify. In this situation the molten pool would become a three-phase mixture: e.g., a solid and liquid slurry formed by the molten pool as it cools to a temperature below the temperature of liquidus, agitated by the gases formed in the concrete ablation process. The present work quantifies the partition of the heat losses upward and downward in this multi-layered configuration, considering the influence of the viscosity and the solid fraction in the pool, from test data obtained from intermediate scale experiments at the University of Wisconsin-Madison. These experimental results show heat transfer behavior for multi-layered pools for a range of viscosities and solid fractions. These results are compared to previous experimental studies and well known correlations and models

  2. Osmotic Control of opuA Expression in Bacillus subtilis and Its Modulation in Response to Intracellular Glycine Betaine and Proline Pools

    Science.gov (United States)

    Hoffmann, Tamara; Wensing, Annette; Brosius, Margot; Steil, Leif; Völker, Uwe

    2013-01-01

    Glycine betaine is an effective osmoprotectant for Bacillus subtilis. Its import into osmotically stressed cells led to the buildup of large pools, whose size was sensitively determined by the degree of the osmotic stress imposed. The amassing of glycine betaine caused repression of the formation of an osmostress-adaptive pool of proline, the only osmoprotectant that B. subtilis can synthesize de novo. The ABC transporter OpuA is the main glycine betaine uptake system of B. subtilis. Expression of opuA was upregulated in response to both sudden and sustained increases in the external osmolarity. Nonionic osmolytes exerted a stronger inducing effect on transcription than ionic osmolytes, and this was reflected in the development of corresponding OpuA-mediated glycine betaine pools. Primer extension analysis and site-directed mutagenesis pinpointed the osmotically controlled opuA promoter. Deviations from the consensus sequence of SigA-type promoters serve to keep the transcriptional activity of the opuA promoter low in the absence of osmotic stress. opuA expression was downregulated in a finely tuned manner in response to increases in the intracellular glycine betaine pool, regardless of whether this osmoprotectant was imported or was newly synthesized from choline. Such an effect was also exerted by carnitine, an effective osmoprotectant for B. subtilis that is not a substrate for the OpuA transporter. opuA expression was upregulated in a B. subtilis mutant that was unable to synthesize proline in response to osmotic stress. Collectively, our data suggest that the intracellular solute pool is a key determinant for the osmotic control of opuA expression. PMID:23175650

  3. Delineating probabilistic species pools in ecology and biogeography

    OpenAIRE

    Karger, Dirk Nikolaus; Cord, Anna F; Kessler, Michael; Kreft, Holger; Kühn, Ingolf; Pompe, Sven; Sandel, Brody; Sarmento Cabral, Juliano; Smith, Adam B; Svenning, Jens-Christian; Tuomisto, Hanna; Weigelt, Patrick; Wesche, Karsten

    2016-01-01

    Aim To provide a mechanistic and probabilistic framework for defining the species pool based on species-specific probabilities of dispersal, environmental suitability and biotic interactions within a specific temporal extent, and to show how probabilistic species pools can help disentangle the geographical structure of different community assembly processes. Innovation Probabilistic species pools provide an improved species pool definition based on probabilities in conjuncti...

  4. Pool water cleaning facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro [Hitachi Ltd., Tokyo (Japan); Asano, Takashi

    1998-05-29

    Only one system comprising a suppression poor water cleaning system (SPCU) and a filtration desalting tower (F/D) is connected for a plurality of nuclear power plants. Pipelines/valves for connecting the one system of the SPCU pump, the F/D and the plurality of nuclear power plants are disposed, and the system is used in common with the plurality of nuclear power plants. Pipelines/valves for connecting a pipeline for passing SP water to the commonly used SPCU pump and a skimmer surge tank are disposed, and fuel pool water is cooled and cleaned by the commonly used SPCU pump and the commonly used F/D. The number of SPCU pumps and the F/D facilities can be reduced, and a fuel pool water cooling operation mode and a fuel pool water cleaning operation mode which were conducted by an FPC pump so far are conducted by the SPCU pump. (N.H.)

  5. Current operating practices of nuclear insurance pools

    International Nuclear Information System (INIS)

    O'Connell, J.M.

    1993-01-01

    This paper discusses the nuclear pooling system and co-operation between the pools, present practice and capacity, with a breakdown of the limits for third party liability and material damage. The author also describes the relationship between the pools and the nuclear operators (the policyholders), and concludes that the nuclear pools have been successful in serving the interests of their member companies, their policyholders and the governments as they have provided a stable insurance market by making available capacity in amounts that had never before been assembled and placed at risk in a single location. 2 tabs

  6. Heat transfer from internally heated hemispherical pools

    International Nuclear Information System (INIS)

    Gabor, J.D.; Ellsion, P.G.; Cassulo, J.C.

    1980-01-01

    Experiments were conducted on heat transfer from internally heated ZnSO 4 -H 2 O pools to the walls of hemispherical containers. This experimental technique provides data for a heat transfer system that has to date been only theoretically treated. Three different sizes of copper hemispherical containers were used: 240, 280, 320 mm in diameter. The pool container served both as a heat transfer surface and as an electrode. The opposing electrode was a copper disk, 50 mm in diameter located at the top of the pool in the center. The top surface of the pool was open to the atmosphere

  7. Study on the Safety Classification Criteria of Mechanical Systems and Components for Open Pool-Type Research Reactors

    International Nuclear Information System (INIS)

    Belal, Al Momani; Jo, Jong Chull

    2013-01-01

    This paper describes a new compromised safety classification approach based on the comparative study of the different practices in safety classification of mechanical systems and components of open pool-type RRs, which have been adopted by several developed countries in the nuclear power area. It is hoped that the proposed safety classification criteria will be used to develop a harmonized consensus international standard. Different safety classification criteria for systems, structures, and components (SSCs) of nuclear reactors are used among the countries that export or import nuclear reactor technology, which may make the nuclear technology trade and exchange difficult. Thus, such various different approaches of safety classification need to be compromised to establish a global standard. This article proposes practicable optimized criteria for safety classification of SSCs for open pool-type research reactors (RRs)

  8. Study on the Safety Classification Criteria of Mechanical Systems and Components for Open Pool-Type Research Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Belal, Al Momani [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Jo, Jong Chull [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    This paper describes a new compromised safety classification approach based on the comparative study of the different practices in safety classification of mechanical systems and components of open pool-type RRs, which have been adopted by several developed countries in the nuclear power area. It is hoped that the proposed safety classification criteria will be used to develop a harmonized consensus international standard. Different safety classification criteria for systems, structures, and components (SSCs) of nuclear reactors are used among the countries that export or import nuclear reactor technology, which may make the nuclear technology trade and exchange difficult. Thus, such various different approaches of safety classification need to be compromised to establish a global standard. This article proposes practicable optimized criteria for safety classification of SSCs for open pool-type research reactors (RRs)

  9. Cooling device for reactor suppression pool

    International Nuclear Information System (INIS)

    Togasaki, Susumu; Kato, Kiyoshi.

    1994-01-01

    In a cooling device of a reactor suppression pool, when a temperature of pool water is abnormally increased and a heat absorbing portion is heated by, for example, occurrence of an accident, coolants are sent to the outside of the reactor container to actuates a thermally operating portion by the heat energy of coolants and drive heat exchanging fluids of a secondary cooling system. If the heat exchanging fluids are sent to a cooling portion, the coolants are cooled and returned to the heat absorbing portion of the suppression pool water. If the heat absorbing portion is heat pipes, the coolants are evaporated by heat absorbed from the suppression pool water, steams are sent to the thermally operating portion, then coolants are liquefied and caused to return to the heat absorbing portion. If the thermal operation portion is a gas turbine, the gas turbine is operated by the coolants, and it is converted to a rotational force to drive heat exchanging fluids by pumps. By constituting the cooling portion with a condensator, the coolants are condensed and liquefied and returned to the heat absorbing portion of the suppression pool water. (N.H.)

  10. Structure of pool in reactor building

    International Nuclear Information System (INIS)

    Yokoyama, Shigeki.

    1997-01-01

    Shielding walls made of iron-reinforced concrete having a metal liner including two body walls rigidly combined to the upper surface of a reactor container are disposed at least to one of an equipment pool or spent fuel storage pool in a reactor building. A rack for temporarily placing an upper lattice plate is detachably attached at least above one of a steam dryer or a gas/liquid separator temporarily placed in the temporary pool, and the height from the bottom portion to the upper end of the shielding wall is determined based on the height of an upper lattice plate temporary placed on the rack and the water depth required for shielding radiation from the upper lattice plate. An operator's exposure on the operation floor can be reduced by the shielding wall, and radiation dose from the spent fuels is reduced. The increase of the height of a pool guarder enhances bending resistance as a ceiling. In addition, the total height of them is made identical with the depth of the spent fuel storage pool thereby enabling to increase storage area for spent fuels. (N.H.)

  11. Understanding newly discovered oscillation modes in magnetically shielded Hall thrusters utilizing state of the art high speed diagnostics.

    Data.gov (United States)

    National Aeronautics and Space Administration — I propose to investigate the newly discovered oscillation modes specific to Magnetically Shied (MS) Hall Effect Thrusters (HET). Although HETs are classified as a...

  12. Pool gateway seal

    International Nuclear Information System (INIS)

    Starr, J.A.; Steinert, L.A.

    1983-01-01

    A device for sealing a gateway between interconnectable pools in a nuclear facility comprising a frame supporting a liquid impermeable sheet positioned in a u-shaped gateway between the pools. An inflatable tube carried in a channel in the periphery of the frame and adjoining the gateway provides a seal therebetween when inflated. A restraining arrangement on the bottom edge of the frame is releasably engagable with an adjacent portion of the gateway to restrict the movement of the frame in the u-shaped gateway upon inflation of the tube, thereby enhancing the seal. The impermeable sheet is formed of an elastomer and thus is conformable to a liquid permeable supportive wall upon application of liquid pressure to the side of the sheet opposite the wall

  13. Recent advances in probabilistic species pool delineations

    Directory of Open Access Journals (Sweden)

    Dirk Nikolaus Karger

    2016-07-01

    Full Text Available A species pool is the set of species that could potentially colonize and establish within a community. It has been a commonly used concept in biogeography since the early days of MacArthur and Wilson’s work on Island Biogeography. Despite their simple and appealing definition, an operational application of species pools is bundled with a multitude of problems, which have often resulted in arbitrary decisions and workarounds when defining species pools. Two recently published papers address the operational problems of species pool delineations, and show ways of delineating them in a probabilistic fashion. In both papers, species pools were delineated using a process-based, mechanistical approach, which opens the door for a multitude of new applications in biogeography. Such applications include detecting the hidden signature of biotic interactions, disentangling the geographical structure of community assembly processes, and incorporating a temporal extent into species pools. Although similar in their conclusions, both ‘probabilistic approaches’ differ in their implementation and definitions. Here I give a brief overview of the differences and similarities of both approaches, and identify the challenges and advantages in their application.

  14. Influence of corium oxidation on fission product release from molten pool

    Energy Technology Data Exchange (ETDEWEB)

    Bechta, S.V., E-mail: bechta@sbor.spb.s [Alexandrov Scientific-Research Institute of Technology (NITI), Sosnovy Bor (Russian Federation); Krushinov, E.V.; Vitol, S.A.; Khabensky, V.B.; Kotova, S.Yu.; Sulatsky, A.A. [Alexandrov Scientific-Research Institute of Technology (NITI), Sosnovy Bor (Russian Federation); Gusarov, V.V.; Almyashev, V.I. [Grebenschikov Institute of Silicate Chemistry of the Russian Academy of Sciences (ISC RAS), St. Petersburg (Russian Federation); Ducros, G.; Journeau, C. [CEA, DEN, Cadarache, F-13108 St. Paul lez Durance (France); Bottomley, D. [Joint Research Centre Institut fuer Transurane (ITU), Karlsruhe (Germany); Clement, B. [Institut de Radioprotection et Surete Nucleaire (IRSN), St. Paul lez Durance (France); Herranz, L. [CIEMAT, Madrid (Spain); Guentay, S. [PSI, Wuerenlingen (Switzerland); Trambauer, K. [GRS, Muenchen (Germany); Auvinen, A. [VTT, Espoo (Finland); Bezlepkin, V.V. [SPbAEP, St. Petersburg (Russian Federation)

    2010-05-15

    Qualitative and quantitative determination of the release of low-volatile fission products and core materials from molten oxidic corium was investigated in the EVAN project under the auspices of ISTC. The experiments carried out in a cold crucible with induction heating and RASPLAV test facility are described. The results are discussed in terms of reactor application; in particular, pool configuration, melt oxidation kinetics, critical influence of melt surface temperature and oxidation index on the fission product release rate, aerosol particle composition and size distribution. The relevance of measured high release of Sr from the molten pool for the reactor application is highlighted. Comparisons of the experimental data with those from the COLIMA CA-U3 test and the VERCORS tests, as well as with predictions from IVTANTHERMO and GEMINI/NUCLEA codes are made. Recommendations for further investigations are proposed following the major observations and discussions.

  15. Chinese nuclear insurance and Chinese nuclear insurance pool

    International Nuclear Information System (INIS)

    Gong Zhiqi

    2000-01-01

    Chinese Nuclear Insurance Started with Daya Bay Nuclear Power Station, PICC issued the insurance policy. Nuclear insurance cooperation between Chinese and international pool's organizations was set up in 1989. In 1996, the Chinese Nuclear Insurance Pool was prepared. The Chinese Nuclear Insurance Pool was approved by The Chinese Insurance Regulatory Committee in May of 1999. The principal aim is to centralize maximum the insurance capacity for nuclear insurance from local individual insurers and to strengthen the reinsurance relations with international insurance pools so as to provide the high quality insurance service for Chinese nuclear industry. The Member Company of Chinese Nuclear Pool and its roles are introduced in this article

  16. Guide for decontaminating swimming pool at schools

    International Nuclear Information System (INIS)

    Matsuhashi, Shimpei; Kurikami, Hiroshi; Yasuda, Ryo; Takano, Takao; Seko, Noriaki; Naganawa, Hirochika; Kuroki, Ryota; Saegusa, Jun

    2012-07-01

    Because of TEPCO Fukushima Dai-ichi Nuclear Power Plant accident due to the Great East Japan Earthquake, a huge amount of radioactive materials was widely dispersed and precipitated into the environment. Swimming pools in Fukushima prefectures were contaminated with the radioactives. We JAEA carried out several demonstration tests to decontaminate the radioactives and discharge the pool water safely. We concluded the results obtained from the tests as 'Guide for decontaminating Swimming Pool at School' and released it quickly. Following this, we also released the guide in English. This manuscript, as an experimental report of the swimming pool water decontamination, is consisted from the guide in Japanese and English prepared. (author)

  17. Guide for decontaminating swimming pool at schools

    Energy Technology Data Exchange (ETDEWEB)

    Matsuhashi, Shimpei; Kurikami, Hiroshi; Yasuda, Ryo; Takano, Takao; Seko, Noriaki; Naganawa, Hirochika; Kuroki, Ryota; Saegusa, Jun

    2012-07-15

    Because of TEPCO Fukushima Dai-ichi Nuclear Power Plant accident due to the Great East Japan Earthquake, a huge amount of radioactive materials was widely dispersed and precipitated into the environment. Swimming pools in Fukushima prefectures were contaminated with the radioactives. We JAEA carried out several demonstration tests to decontaminate the radioactives and discharge the pool water safely. We concluded the results obtained from the tests as 'Guide for decontaminating Swimming Pool at School' and released it quickly. Following this, we also released the guide in English. This manuscript, as an experimental report of the swimming pool water decontamination, is consisted from the guide in Japanese and English prepared. (author)

  18. (Important hygienic aspects for swimming pools (author's transl))

    Energy Technology Data Exchange (ETDEWEB)

    Somosi, G

    1981-01-01

    The major epidemics which occurred in Hungary and originated from water in swimming pools are reported. The difficulties encountered in producing epidemiological evidence and in monitoring infections originating from water in swimming pools are mentioned. The possibilities of controlling the water quality in swimming pools and of preventing infections are discussed. Reference is made to the existing bacteriological limit values in Hungary to be observed in the recirculation of water in swimming pools.

  19. Application of pooled genotyping to scan candidate regions for association with HDL cholesterol levels

    Directory of Open Access Journals (Sweden)

    Hinds David A

    2004-11-01

    Full Text Available Abstract Association studies are used to identify genetic determinants of complex human traits of medical interest. With the large number of validated single nucleotide polymorphisms (SNPs currently available, two limiting factors in association studies are genotyping capability and costs. Pooled DNA genotyping has been proposed as an efficient means of screening SNPs for allele frequency differences in case-control studies and for prioritising them for subsequent individual genotyping analysis. Here, we apply quantitative pooled genotyping followed by individual genotyping and replication to identify associations with human serum high-density lipoprotein (HDL cholesterol levels. The DNA from individuals with low and high HDL cholesterol levels was pooled separately, each pool was amplified by polymerase chain reaction in triplicate and each amplified product was separately hybridised to a high-density oligonucleotide array. Allele frequency differences between case and control groups with low and high HDL cholesterol levels were estimated for 7,283 SNPs distributed across 71 candidate gene regions spanning a total of 17.1 megabases. A novel method was developed to take advantage of independently derived haplotype map information to improve the pooled estimates of allele frequency differences. A subset of SNPs with the largest estimated allele frequency differences between low and high HDL cholesterol groups was chosen for individual genotyping in the study population, as well as in a separate replication population. Four SNPs in a single haplotype block within the cholesteryl ester transfer protein (CETP gene interval were significantly associated with HDL cholesterol levels in both populations. Our study is among the first to demonstrate the application of pooled genotyping followed by confirmation with individual genotyping to identify genetic determinants of a complex trait.

  20. An Innovative Hybrid Loop-Pool SFR Design and Safety Analysis Methods: Today and Tomorrow

    International Nuclear Information System (INIS)

    Hongbin Zhang; Haihua Zhao; Vincent Mousseau

    2008-01-01

    Investment in commercial sodium cooled fast reactor (SFR) power plants will become possible only if SFRs achieve economic competitiveness as compared to light water reactors and other Generation IV reactors. Toward that end, we have launched efforts to improve the economics and safety of SFRs from the thermal design and safety analyses perspectives at Idaho National Laboratory. From the thermal design perspective, an innovative hybrid loop-pool SFR design has been proposed. This design takes advantage of the inherent safety of a pool design and the compactness of a loop design to further improve economics and safety. From the safety analyses perspective, we have initiated an effort to develop a high fidelity reactor system safety code

  1. The effect of preceptor role effectiveness on newly licensed registered nurses' perceived psychological empowerment and professional autonomy.

    Science.gov (United States)

    Watkins, Chanell; Hart, Patricia L; Mareno, Nicole

    2016-03-01

    The first year turnover rate for newly licensed registered nurses is roughly 30% and increases to about 57% in the second year (Twibell et al., 2012). An effective preceptorship has been shown to better facilitate the first year transition (Hodges et al., 2008) and increase retention rates (Pine and Tart, 2007). The purpose of this study was to examine the relationships between newly licensed registered nurses' perceived preceptor role effectiveness, psychological empowerment and professional autonomy. A prospective, cross-sectional, descriptive research design was used. Sixty-nine newly licensed registered nurses were recruited and surveyed. Newly licensed registered nurses were found to have moderately high levels of perceived preceptor role effectiveness, psychological empowerment, and professional autonomy. Preceptor role effectiveness had significant, moderately, positive relationships with professional autonomy and psychological empowerment. There was also a significant relationship found between professional autonomy and psychological empowerment. Results show that preceptor role effectiveness is linked to increased professional autonomy and psychological empowerment. Therefore, effective preceptorships are necessary in easing the newly licensed registered nurse's transition to practice. Strategies to ensure effective preceptorships and enhance the NRLN's transition to practice are proposed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Studies of thermal stratification in water pool

    International Nuclear Information System (INIS)

    Verma, P.K.; Chandraker, D.K.; Nayak, A.K.; Vijayan, P.K.

    2015-01-01

    Large water pools are used as a heat sink for various cooling systems used in industry. In context of advance nuclear reactors like AHWR, it is used as ultimate heat sink for passive systems for decay heat removal and containment cooling. This system incorporates heat exchangers submerged in the large water pool. However, heat transfer by natural convection in pool poses a problem of thermal stratification. Due to thermal stratification hot layers of water accumulate over the relatively cold one. The heat transfer performance of heat exchanger gets deteriorated as a hot fluid envelops it. In the nuclear reactors, the walls of the pool are made of concrete and it may subject to high temperature due to thermal stratification which is not desirable. In this paper, a concept of employing shrouds around the heat source is studied. These shrouds provide a bulk flow in the water pool, thereby facilitating mixing of hot and cold fluid, which eliminate stratification. The concept has been applied to the a scaled model of Gravity Driven Water Pool (GDWP) of AHWR in which Isolation Condensers (IC) tubes are submerged for decay heat removal of AHWR using ICS and thermal stratification phenomenon was predicted with and without shrouds. To demonstrate the adequacy of the effectiveness of shroud arrangement and to validate the simulation methodology of RELAP5/Mod3.2, experiments has been conducted on a scaled model of the pool with and without shroud. (author)

  3. Thermal analyses of solar swimming pool heating in Pakistan

    International Nuclear Information System (INIS)

    Ahmad, I.

    2011-01-01

    Hotels and swimming clubs in Pakistan pay huge gas bills for heating Swimming pools in winter. Winter days in most parts of Pakistan remain sunny and unglazed low cost solar collectors may be used to extend the swimming season. Installing the pool in a wind-protected area, which receives unobstructed solar radiation, may further reduce the size of the solar collectors required to heat the swimming pools. The pools should be covered with plastic sheet to eliminate evaporative heat losses and to prevent dust and tree leaves falling in the pool. The results of the thermal analysis show that in some parts of the country, a solar exposed pool can maintain comfortable temperature simply by using a plastic sheet on the pool surface. On the other hand, there are cities where solar collector array equal to twice the surface area of the pool is required to keep desired temperature in winter. (author)

  4. Reduction of the pool-top radiation level in HANARO

    International Nuclear Information System (INIS)

    Lee, Choong-Sung; Park, Sang-Jun; Kim, Heonil; Park, Yong-Chul; Choi, Young-San

    1999-01-01

    HANARO is an open-tank-in-pool type reactor. Pool water is the only shielding to minimize the pool top radiation level. During the power ascension test of HANARO, the measured pool top radiation level was higher than the design value because some of the activation products in the coolant reached the pool surface. In order to suppress this rising coolant, the hot water layer system (HWL) was designed and installed to maintain l.2 meter-deep hot water layer whose temperature is 5degC higher than that of the underneath pool surface. After the installation of the HWL system, however, the radiation level of the pool-top did not satisfy the design value. The operation modes of the hot water layer system and the other systems in the reactor pool, which had an effect on the formation of the hot water layer, were changed to reduce pool-top radiation level. After the above efforts, the temperature and the radioactivity distribution in the pool was measured to confirm whether this system blocked the rising coolant. The radiation level at the pool-top was significantly reduced below one tenth of that before installing the HWL and satisfied the design value. It was also confirmed by calculation that this hot water layer system would significantly reduce the release of fission gases to the reactor hall and the environment during the hypothetical accident as well. (author)

  5. 17 CFR 4.22 - Reporting to pool participants.

    Science.gov (United States)

    2010-04-01

    ..., the financial statements are not required to include consolidated information for all series. (7) For... event that the International Financial Reporting Standards require consolidated financial statements for... reporting pool's consolidated financial statements. (ii) The commodity pool operator of a pool that meets...

  6. Behavior of spent nuclear fuel in water pool storage

    International Nuclear Information System (INIS)

    Johnson, A.B. Jr.

    1977-09-01

    Storage of irradiated nuclear fuel in water pools (basins) has been standard practice since nuclear reactors first began operation approximately 34 years ago. Pool storage is the starting point for all other fuel storage candidate processes and is a candidate for extended interim fuel storage until policy questions regarding reprocessing and ultimate disposal have been resolved. This report assesses the current performance of nuclear fuel in pool storage, the range of storage conditions, and the prospects for extending residence times. The assessment is based on visits to five U.S. and Canadian fuel storage sites, representing nine storage pools, and on discussions with operators of an additional 21 storage pools. Spent fuel storage experience from British pools at Winfrith and Windscale and from a German pool at Karlsruhe (WAK) also is summarized

  7. Design of the Demineralized Water Make-up Line to Maintain the Normal Pool Water Level of the Reactor Pool in the Research Reactor

    International Nuclear Information System (INIS)

    Yoon, Hyun Gi; Choi, Jung Woon; Yoon, Ju Hyeon; Chi, Dae Young

    2012-01-01

    In many research reactors, hot water layer system (HWLS) is used to minimize the pool top radiation level. Reactor pool divided into the hot water layer at the upper part of pool and the cold part below the hot water layer with lower temperature during normal operation. Water mixing between these layers is minimized because the hot water layer is formed above cold water. Therefore the hot water layer suppresses floatation of cold water and reduces the pool top radiation level. Pool water is evaporated form the surface to the building hall because of high temperature of the hot water layer; consequently the pool level is continuously fallen. Therefore, make-up water is necessary to maintain the normal pool level. There are two way to supply demineralized water to the pool, continuous and intermittent methods. In this system design, the continuous water make-up method is adopted to minimize the disturbance of the reactor pool flow. Also, demineralized water make-up is connected to the suction line of the hot water layer system to raise the temperature of make-up water. In conclusion, make-up demineralized water with high temperature is continuously supplied to the hot water layer in the pool

  8. Condensation in a two-phase pool

    International Nuclear Information System (INIS)

    Duffey, R.B.; Hughes, E.D.

    1991-01-01

    We consider the case of vapor condensation in a liquid pool, when the heat transfer is controlled by heat losses through the walls. The analysis is based on drift flux theory for phase separation in the pool, and determines the two-phase mixture height for the pool. To our knowledge this is the first analytical treatment of this classic problem that gives an explicit result, previous work having established the result for the evaporative case. From conservation of mass and energy in a one-dimensional steady flow, together with a void relation between the liquid and vapor fluxes, we determine the increase in the mixture level from the base level of the pool. It can be seen that the thermal and hydrodynamic influences are separable. Thus, the thermal influence of the wall heat transfer appears through its effect on the condensing length L*, so that at high condensation rates the pool is all liquid, and at low rates overflows (the level swell or foaming effect). Similarly, the phase separation effect hydrodynamically determines the height via the relative velocity of the mixture to the entering flux. We examine some practical applications of this result to level swell in condensing flows, and also examine some limits in ideal cases

  9. Role of work overload toward turnover intention among newly hired public accountants

    OpenAIRE

    Pradana, Andika; Salehudin, Imam

    2013-01-01

    This paper aims to analyze how work overload influences turnover intentions of newly hired public accountants. Job satisfaction, work related stress and work life conflicts are used as mediating variable between work overload and turnover intention. This study employed 141 auditors from several accounting firms operating in the Greater Jakarta region. Six proposed hypotheses was tested using Structural Equation Modeling (SEM). Results showed that work overload has significant effect in increa...

  10. A skeleton for distributed work pools in Eden

    DEFF Research Database (Denmark)

    Dieterle, Mischa; Berthold, Jost; Loogen, Rita

    2010-01-01

    We present a flexible skeleton for implementing distributed work pools in our parallel functional language Eden. The skeleton manages a pool of tasks (work pool) in a distributed manner using a demand-driven work stealing approach for load balancing. All coordination is done locally within...

  11. Sustainability of common pool resources

    OpenAIRE

    Timilsina, Raja Rajendra; Kotani, Koji; Kamijo, Yoshio

    2017-01-01

    Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as "capitalism," affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepales...

  12. The Nuclear Insurance Pools: Operations and Covers

    International Nuclear Information System (INIS)

    Tetley, M.

    2008-01-01

    Nuclear insurance pools have provided insurance for the nuclear industry for over fifty years and it is fair to say that the development of civil nuclear power would not have been possible without the support of the commercial insurance market. The unknown risks presented by the nascent nuclear power industry in the 1950s required a leap of faith by insurers who developed specialist pooled insurance capacity to ensure adequate capacity to back up the operators' compensation obligations. Since then, nuclear insurance pools have evolved to become comprehensive suppliers of most types of insurance for nuclear plant globally. This paper will outline the structure, development, products and current operations of nuclear insurance pools.(author)

  13. Shedding Light on Dark Liquidity Pools

    NARCIS (Netherlands)

    Degryse, H.A.; van Achter, M.; Wuyts, G.

    2008-01-01

    This article reviews the recent developments on dark liquidity pools starting from the theoretical and empirical academic literature. The number of dark liquidity pools as well as their trading volume has grown substantially in the last couple of years. We highlight the incentives of providers as

  14. NACUBO's Guide to Unitizing Investment Pools. Second Edition

    Science.gov (United States)

    Wheeler, Mary S.

    2011-01-01

    The National Association of College and University Business Officers' (NACUBO's) "Guide to Unitizing Investment Pools" addresses the principles and concepts for administering a consolidated investment pool. Unitization is the mechanism by which investment funds are pooled to maximize investment efficiencies and provide information for donors,…

  15. Investigation of the condition of spent-fuel pool components

    International Nuclear Information System (INIS)

    Kustas, F.M.; Bates, S.O.; Opitz, B.E.; Johnson, A.B. Jr.; Perez, J.M. Jr.; Farnsworth, R.K.

    1981-09-01

    It is currently projected that spent nuclear fuel, which is discharged from the reactor and then stored in water pools, may remain in those pools for several decades. Other studies have addressed the expected integrity of the spent fuel during extended water storage; this study assesses the integrity of metallic spent fuel pool components. Results from metallurgical examinations of specimens taken from stainless steel and aluminum components exposed in spent fuel pools are presented. Licensee Event Reports (LERs) relating to problems with spent fuel components were assessed and are summarized to define the types of operational problems that have occurred. The major conclusions of this study are: aluminum and stainless steel spent fuel pool components have a good history of performance in both deionized and borated water pools. Although some operational problems involving pool components have occurred, these problems have had minimal impacts

  16. Investigation of the condition of spent-fuel pool components

    Energy Technology Data Exchange (ETDEWEB)

    Kustas, F.M.; Bates, S.O.; Opitz, B.E.; Johnson, A.B. Jr.; Perez, J.M. Jr.; Farnsworth, R.K.

    1981-09-01

    It is currently projected that spent nuclear fuel, which is discharged from the reactor and then stored in water pools, may remain in those pools for several decades. Other studies have addressed the expected integrity of the spent fuel during extended water storage; this study assesses the integrity of metallic spent fuel pool components. Results from metallurgical examinations of specimens taken from stainless steel and aluminum components exposed in spent fuel pools are presented. Licensee Event Reports (LERs) relating to problems with spent fuel components were assessed and are summarized to define the types of operational problems that have occurred. The major conclusions of this study are: aluminum and stainless steel spent fuel pool components have a good history of performance in both deionized and borated water pools. Although some operational problems involving pool components have occurred, these problems have had minimal impacts.

  17. Analysis of the loss of pool cooling accident in a PWR spent fuel pool with MAAP5

    International Nuclear Information System (INIS)

    Wu, Xiaoli; Li, Wei; Zhang, Yapei; Tian, Wenxi; Su, Guanghui; Qiu, Suizheng

    2014-01-01

    Highlights: • A PWR spent fuel pool was modeled by using MAAP5. • Loss of pool cooling severe accident scenarios were studied. • Loss of pool cooling accidents with two mitigation measures were analyzed. - Abstract: The Fukushima Daiichi nuclear accident shows that it is necessary to study potential severe accidents and corresponding mitigation measures for the spent fuel pool (SFP) of a nuclear power plant (NPP). This paper presents the analysis of loss of pool cooling accident scenarios and the discussion of mitigation measures for the SFP at a pressurized water reactor (PWR) NPP with the MAAP5 code. Analysis of uncompensated loss of water due to the loss of pool cooling with different initial pool water levels of 12.2 m (designated as a reference case) and 10.7 m have been performed based on a MAAP5 input model. Scenarios of the accident such as overheating of uncovered fuel assemblies, oxidation of claddings and hydrogen generation, loss of intactness of fuel rod claddings, and release of radioactive fission products were predicted with the assumption that mitigation measures were unavailable. The results covered a broad spectrum of severe accident evaluations in the SFP. Furthermore, as important mitigation measures, the effects of recovering the SFP cooling system and makeup water in SFP on the accident progressions have also been investigated respectively based on the events of pool water boiling and spent fuels uncovery. Based upon the reference case, three cases with the recovery of SFP cooling system and three other cases with makeup water in SFP have been studied. The results showed that, severe accident might happen if SFP cooling system was not restored timely before the spent fuels started to become uncovered; spent fuels could be completely submerged and severe accident might be avoided if SFP makeup water system provided water with a mass flow rate larger than the average evaporation rate defined as the division of pool water mass above the

  18. Framework for the analysis of reactive power dispatch in energy pools

    International Nuclear Information System (INIS)

    Salgado, R.S.; Irving, M.R.

    2004-01-01

    This paper proposes a framework for the simulation and analysis of the reactive power distribution in electric energy markets of the pool type. Firstly, the analytical formulation of the OPF problem, with three optional performance indexes for the reactive power dispatch, is discussed. These OPF objectives are used to determine the reactive power distribution for a given active power dispatch (obtained through merit-order strategy, for instance). An allocation strategy is used to assess the participation of each power system agent in the loss/reactive power distribution. This strategy uses the premise of co-operative game theory. Numerical results obtained with the Ward-Hale 6-bus test system illustrate the main aspects of the proposed methodology. (author)

  19. Classification of Alzheimer's Disease Based on Eight-Layer Convolutional Neural Network with Leaky Rectified Linear Unit and Max Pooling.

    Science.gov (United States)

    Wang, Shui-Hua; Phillips, Preetha; Sui, Yuxiu; Liu, Bin; Yang, Ming; Cheng, Hong

    2018-03-26

    Alzheimer's disease (AD) is a progressive brain disease. The goal of this study is to provide a new computer-vision based technique to detect it in an efficient way. The brain-imaging data of 98 AD patients and 98 healthy controls was collected using data augmentation method. Then, convolutional neural network (CNN) was used, CNN is the most successful tool in deep learning. An 8-layer CNN was created with optimal structure obtained by experiences. Three activation functions (AFs): sigmoid, rectified linear unit (ReLU), and leaky ReLU. The three pooling-functions were also tested: average pooling, max pooling, and stochastic pooling. The numerical experiments demonstrated that leaky ReLU and max pooling gave the greatest result in terms of performance. It achieved a sensitivity of 97.96%, a specificity of 97.35%, and an accuracy of 97.65%, respectively. In addition, the proposed approach was compared with eight state-of-the-art approaches. The method increased the classification accuracy by approximately 5% compared to state-of-the-art methods.

  20. Swimming-pool piles; Piles piscines

    Energy Technology Data Exchange (ETDEWEB)

    Trioulaire, M [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In France two swimming-pool piles, Melusine and Triton, have just been set in operation. The swimming-pool pile is the ideal research tool for neutron fluxes of the order of 10{sup 13}. This type of pile can be of immediate interest to many research centres, but its cost must be reduced and a break with tradition should be observed in its design. It would be an advantage: - to bury the swimming-pool; - to reject the experimental channel; - to concentrate the cooling circuit in the swimming-pool; - to carry out all manipulations in the water; - to double the core. (author) [French] En France, deux piles piscines, Melusine et Triton, viennent d'entrer en service. La pile piscine est l'outil de recherche ideal pour des flux de neutrons de l'ordre de 10{sup 13}. Ce type de pile peut interesser des maintenant de nombreux centres de recherches mais il faut reduire son prix de revient et rompre avec le conformisme de sa conception. Il y a avantage: - a enterrer la piscine; - a supprimer les canaux experimentaux; - a concentrer le circuit de refrigeration dans la piscine; - a effectuer toutes les manipulations dans l'eau; - a doubler le coeur. (auteur)

  1. A novel intracellular pool of LFA-1 is critical for asymmetric CD8+ T cell activation and differentiation.

    Science.gov (United States)

    Capece, Tara; Walling, Brandon L; Lim, Kihong; Kim, Kyun-Do; Bae, Seyeon; Chung, Hung-Li; Topham, David J; Kim, Minsoo

    2017-11-06

    The integrin lymphocyte function-associated antigen 1 (LFA-1; CD11a/CD18) is a key T cell adhesion receptor that mediates stable interactions with antigen-presenting cell (APC), as well as chemokine-mediated migration. Using our newly generated CD11a-mYFP knock-in mice, we discovered that naive CD8 + T cells reserve a significant intracellular pool of LFA-1 in the uropod during migration. Intracellular LFA-1 quickly translocated to the cell surface with antigenic stimulus. Importantly, the redistribution of intracellular LFA-1 at the contact with APC was maintained during cell division and led to an unequal inheritance of LFA-1 in divided T cells. The daughter CD8 + T cells with disparate LFA-1 expression showed different patterns of migration on ICAM-1, APC interactions, and tissue retention, as well as altered effector functions. In addition, we identified Rab27 as an important regulator of the intracellular LFA-1 translocation. Collectively, our data demonstrate that an intracellular pool of LFA-1 in naive CD8 + T cells plays a key role in T cell activation and differentiation. © 2017 Capece et al.

  2. Plant diversity associated with pools in natural and restored peatlands

    Directory of Open Access Journals (Sweden)

    N. Fontaine

    2007-06-01

    Full Text Available This study describes plant assemblages associated with the edges of peatland pools. We conducted inventories in six natural peatlands in the province of Québec (Canada in order to measure the contribution of pools to species diversity in climatic regions where peatlands are used for peat extraction. We also carried out vegetation surveys in a peatland that has been restored after peat extraction/harvesting to determine whether pool vegetation establishes along the edges of created pools when dry surface restoration techniques only are used. Pools enhanced plant species richness in natural peatlands. Around created pools, species associated with natural pools were still absent, and non-bog species were present, six years after restoration. On this basis, we emphasise the importance of preserving natural peatlands with pools. In order to restore fully the plant diversity associated with peatlands at harvested sites, it may be necessary to modify pool excavation techniques so that created pools resemble more closely those in natural peatlands. Active introduction of the plant species or communities associated with natural pools may also be needed; candidate species for North America include Andromeda glaucophylla, Cladopodiella fluitans, Carex limosa, Eriophorum virginicum, Rhynchospora alba and Sphagnum cuspidatum.

  3. Cross-Linking Mast Cell Specific Gangliosides Stimulates the Release of Newly Formed Lipid Mediators and Newly Synthesized Cytokines

    Directory of Open Access Journals (Sweden)

    Edismauro Garcia Freitas Filho

    2016-01-01

    Full Text Available Mast cells are immunoregulatory cells that participate in inflammatory processes. Cross-linking mast cell specific GD1b derived gangliosides by mAbAA4 results in partial activation of mast cells without the release of preformed mediators. The present study examines the release of newly formed and newly synthesized mediators following ganglioside cross-linking. Cross-linking the gangliosides with mAbAA4 released the newly formed lipid mediators, prostaglandins D2 and E2, without release of leukotrienes B4 and C4. The effect of cross-linking these gangliosides on the activation of enzymes in the arachidonate cascade was then investigated. Ganglioside cross-linking resulted in phosphorylation of cytosolic phospholipase A2 and increased expression of cyclooxygenase-2. Translocation of 5-lipoxygenase from the cytosol to the nucleus was not induced by ganglioside cross-linking. Cross-linking of GD1b derived gangliosides also resulted in the release of the newly synthesized mediators, interleukin-4, interleukin-6, and TNF-α. The effect of cross-linking the gangliosides on the MAP kinase pathway was then investigated. Cross-linking the gangliosides induced the phosphorylation of ERK1/2, JNK1/2, and p38 as well as activating both NFκB and NFAT in a Syk-dependent manner. Therefore, cross-linking the mast cell specific GD1b derived gangliosides results in the activation of signaling pathways that culminate with the release of newly formed and newly synthesized mediators.

  4. Grundfoss: Chlorination of Swimming Pools

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Hogan, John; Andreassen, Viggo

    1998-01-01

    Grundfos asked for a model, describing the problem of mixing chemicals, being dosed into water systems, to be developed. The application of the model should be dedicated to dosing aqueous solution of chlorine into swimming pools.......Grundfos asked for a model, describing the problem of mixing chemicals, being dosed into water systems, to be developed. The application of the model should be dedicated to dosing aqueous solution of chlorine into swimming pools....

  5. Livestock Grazing as a Driver of Vernal Pool Ecohydrology

    Science.gov (United States)

    Michaels, J.; McCarten, N. F.

    2017-12-01

    Vernal pools are seasonal wetlands that host rare plant communities of high conservation priority. Plant community composition is largely driven by pool hydroperiod. A previous study found that vernal pools grazed by livestock had longer hydroperiods compared with pools excluded from grazing for 10 years, and suggests that livestock grazing can be used to protect plant diversity. It is important to assess whether observed differences are due to the grazing or due to water balance variables including upland discharge into or out of the pools since no a priori measurements were made of the hydrology prior to grazing. To address this question, in 2016 we compared 15 pools that have been grazed continuously and 15 pools that have been fenced off for over 40 years at a site in Sacramento County. We paired pools based on abiotic characteristics (size, shape, slope, soil type) to minimize natural variation. We sampled vegetation and water depth using Solinst level loggers. We found that plant diversity and average hydroperiod was significantly higher in the grazed pools. We are currently measuring groundwater connectivity and upland inputs in order to compare the relative strength of livestock grazing as a driver of hydroperiod to these other drivers.

  6. Newly Homeless Youth Typically Return Home

    OpenAIRE

    Milburn, Norweeta G.; Rosenthal, Doreen; Rotheram-Borus, Mary Jane; Mallett, Shelley; Batterham, Philip; Rice, Eric; Solorio, Rosa

    2007-01-01

    165 newly homeless adolescents from Melbourne, Australia and 261 from Los Angeles, United States were surveyed and followed for two years. Most newly homeless adolescents returned home (70% U.S., 47% Australia) for significant amounts of time (39% U.S., 17% Australia more than 12 months) within two years of becoming homeless.

  7. The Role of Nuclear Insurance Pools

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    2006-01-01

    Since fifty years insurers respond to the need of both governments and the electricity industry to provide financial protection to cover the perils presented by the use of nuclear energy for peaceful purposes. This paper aims at explaining what difficulties had to be solved in order to enable insurers to provide such protection, that as a solution to these difficulties Nuclear Insurance Pools were formed, how such pools operate and what security they provide. Thereby not only a number of universal principles underlying nuclear pool insurance will be explained, but also some differences in the characteristics of such insurance per group of countries. (author)

  8. Swimming Pool Safety

    Science.gov (United States)

    ... Spread the Word Shop AAP Find a Pediatrician Safety & Prevention Immunizations All Around At Home At Play ... Español Text Size Email Print Share Swimming Pool Safety Page Content ​What is the best way to ...

  9. Nuclear Insurance Pools: World-wide Practice and Prospective

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    2000-01-01

    The following paper explains why Nuclear Insurance Pools were established, how they operate and what insurance protection they offer to the operations of nuclear installations. It will be shown that the clear interrelationship of the Pool-insurance operations, both on a national and an international level, has resulted in a transparency of each individual Pool-Member's exposure, which enables him to make the highest possible commitment to nuclear risks. Finally, some views will be given as regards the future prospective for the long proven method of pooling this particularly sensitive class of business. (author)

  10. Study of void fraction and mixing of immiscible liquids in a pool configuration by an upward gas flow

    International Nuclear Information System (INIS)

    Casas, J.C.; Corradini, M.L.

    1992-01-01

    In this paper, investigations are performed to study the mixing between immiscible liquids in a pool configuration due to an upward gas flow. A water-R113 system is sued in the bubbly/churn-turbulent regimes to determine the effects of the unagitated pool depth on layer mixing. The superficial gas velocity at which full mixing is attained is observed to increase with the pool depth, although it is concluded that this is a weak dependency. Mixing in the churn-turbulent regime is studied with Wood's metal-water and Wood's metal-silicone fluid (100 cS) as pairs of fluids. Additional past mixing data from six other fluids are also included in the data base. A criterion is proposed to determine if two liquids will entrain in bubbly or churn-turbulent flow. Correlations are derived that, for a set of given conditions, allow prediction of the mixing state (mixed or segregated) of a system. Because of the indirect method of measuring the mixed layer thickness, pool void fraction experiments are also performed. For the case of water and R113, the effect of unagitated pool depth on the void fraction is studied

  11. 13 CFR 120.1708 - Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... United States. (c) SBA purchase of a Loan Interest. SBA will determine whether to purchase a Loan... reserves the right to purchase a Loan Interest from a Pool at any time. (d) Self-liquidating. A Pool... market conditions and program experience, and will publish any such change in the Federal Register. (h...

  12. ENERGY SAVING AT OPERATION OF OUTDOOR SWIMMING POOLS

    Directory of Open Access Journals (Sweden)

    V. F. Ivin

    2013-09-01

    Full Text Available Purpose. Energy saving is a major problem in modern power engineering and various energy-consuming devices. They include outdoor swimming pools. In order to maintain them in working condition, especially in winter period, it takes significant amount of thermal energy. Task of heat loss substantial decrease in open swimming pools is considered in the article (on DNURT example. Methodology. The method of determining the mass and heat loss on the basis of criteria equations of heat and mass transfer theory is used. Findings. Calculations of the actual DNURT pool heat loss for different seasons, as for natural convection both for air forced motion above the free water surface are performed. It is shown that for the adiabatic evaporation conditions of water from the pool in winter during blow-off with wind the heat loss can be up to 2 kW/m2 on surface. To reduce these losses it is offered to cover water surface in a pool with a special material with low thermal conductivity on the basis of porous polyethylene during the time when the pool is not used for other purposes. It is shown that the implementation of these standards will reduce the actual heat loss, at least 5-6 times. Originality. The solution of important environmental and energy problem thanks to reducing heat losses by the pool in different times of a year and correspondingly lower emissions of power generating enterprises. Practical value. It is shown that the coating surface of the pool with poorly heat-conducting and easy to install coating will let, at a minimum, to reduce the actual heat loss on 5-6 times and reduce the emissions of power plants generating energy for pool heating.

  13. Numerical analysis of weld pool oscillation in laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung Ho [Chungbuk National University, Cheongju (Korea, Republic of); Farson, Dave F [The Ohio State University, Columbus (United States); Hollis, Kendall; Milewski, John O. [Los Alamos National Laboratory, Los Alamos (United States)

    2015-04-15

    Volume of fluid (VOF) numerical simulation was used to investigate melt flow and volumetric oscillation of conduction-mode pulsed laser weld pools. The result is compared to high speed video stream of titanium laser spot welding experiment. The total simulation time is 10ms with the first 5 ms being heating and melting under constant laser irradiation and the remaining 5 ms corresponding to resolidification of the weld pool. During the melting process, the liquid pool did not exhibit periodic oscillation but was continually depressed by the evaporation recoil pressure. After the laser pulse, the weld pool was excited into volumetric oscillation by the release of pressure on its surface and oscillation of the weld pool surface was analyzed. The simulation model suggested adjusting thermal diffusivity to match cooling rate and puddle diameter during solidification which is distinguishable from previous weld pool simulation. The frequency continuously increased from several thousand cycles per second to tens of thousands of cycles per second as the weld pool solidified and its diameter decreased. The result is the first trial of investigation of small weld pool oscillation in laser welding although there have been several reports about arc welding.

  14. Blanketing effect of expansion foam on liquefied natural gas (LNG) spillage pool

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bin; Liu, Yi [Mary Kay O’Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States); Olewski, Tomasz; Vechot, Luc [Mary Kay O’Connor Process Safety Center - Qatar, Texas A and M University at Qatar, PO Box 23874, Doha (Qatar); Mannan, M. Sam, E-mail: mannan@tamu.edu [Mary Kay O’Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States)

    2014-09-15

    Highlights: • Reveal the existence of blocking effect of high expansion foam on an LNG pool. • Study the blanketing effect of high expansion foam quantitatively. • Correlate heat flux for vaporization with foam breaking rate. • Propose the physical mechanism of blanketing effect. - Abstract: With increasing consumption of natural gas, the safety of liquefied natural gas (LNG) utilization has become an issue that requires a comprehensive study on the risk of LNG spillage in facilities with mitigation measures. The immediate hazard associated with an LNG spill is the vapor hazard, i.e., a flammable vapor cloud at the ground level, due to rapid vaporization and dense gas behavior. It was believed that high expansion foam mitigated LNG vapor hazard through warming effect (raising vapor buoyancy), but the boil-off effect increased vaporization rate due to the heat from water drainage of foam. This work reveals the existence of blocking effect (blocking convection and radiation to the pool) to reduce vaporization rate. The blanketing effect on source term (vaporization rate) is a combination of boil-off and blocking effect, which was quantitatively studied through seven tests conducted in a wind tunnel with liquid nitrogen. Since the blocking effect reduces more heat to the pool than the boil-off effect adds, the blanketing effect contributes to the net reduction of heat convection and radiation to the pool by 70%. Water drainage rate of high expansion foam is essential to determine the effectiveness of blanketing effect, since water provides the boil-off effect.

  15. Blanketing effect of expansion foam on liquefied natural gas (LNG) spillage pool

    International Nuclear Information System (INIS)

    Zhang, Bin; Liu, Yi; Olewski, Tomasz; Vechot, Luc; Mannan, M. Sam

    2014-01-01

    Highlights: • Reveal the existence of blocking effect of high expansion foam on an LNG pool. • Study the blanketing effect of high expansion foam quantitatively. • Correlate heat flux for vaporization with foam breaking rate. • Propose the physical mechanism of blanketing effect. - Abstract: With increasing consumption of natural gas, the safety of liquefied natural gas (LNG) utilization has become an issue that requires a comprehensive study on the risk of LNG spillage in facilities with mitigation measures. The immediate hazard associated with an LNG spill is the vapor hazard, i.e., a flammable vapor cloud at the ground level, due to rapid vaporization and dense gas behavior. It was believed that high expansion foam mitigated LNG vapor hazard through warming effect (raising vapor buoyancy), but the boil-off effect increased vaporization rate due to the heat from water drainage of foam. This work reveals the existence of blocking effect (blocking convection and radiation to the pool) to reduce vaporization rate. The blanketing effect on source term (vaporization rate) is a combination of boil-off and blocking effect, which was quantitatively studied through seven tests conducted in a wind tunnel with liquid nitrogen. Since the blocking effect reduces more heat to the pool than the boil-off effect adds, the blanketing effect contributes to the net reduction of heat convection and radiation to the pool by 70%. Water drainage rate of high expansion foam is essential to determine the effectiveness of blanketing effect, since water provides the boil-off effect

  16. Degradation of Organic UV filters in Chlorinated Seawater Swimming Pools: Transformation Pathways and Bromoform Formation.

    Science.gov (United States)

    Manasfi, Tarek; Coulomb, Bruno; Ravier, Sylvain; Boudenne, Jean-Luc

    2017-12-05

    Organic ultraviolet (UV) filters are used in sunscreens and other personal-care products to protect against harmful effects of exposure to UV solar radiation. Little is known about the fate of UV filters in seawater swimming pools disinfected with chlorine. The present study investigated the occurrence and fate of five commonly used organic UV filters, namely dioxybenzone, oxybenzone, avobenzone, 2-ethylhexyl-4-methoxycinnamate, and octocrylene, in chlorinated seawater swimming pools. Pool samples were collected to monitor the variation of UV filter concentrations during pool opening hours. Furthermore, laboratory-controlled chlorination experiments were conducted in seawater spiked with UV filters to investigate the reactivity of UV filters. Extracts of chlorination reaction samples were analyzed using high-resolution mass spectrometry and electron-capture detection to identify the potentially formed byproducts. In the collected pool samples, all the UV filters except dioxybenzone were detected. Chlorination reactions showed that only octocrylene was stable in chlorinated seawater. The four reactive UV filters generated brominated transformation products and disinfection byproducts. This formation of brominated products resulted from reactions between the reactive UV filters and bromine, which is formed rapidly when chlorine is added to seawater. Based on the identified byproducts, the transformation pathways of the reactive UV filters were proposed for the first time. Bromoform was generated by all the reactive UV filters at different yields. Bromal hydrate was also detected as one of the byproducts generated by oxybenzone and dioxybenzone.

  17. CDC Study Finds Fecal Contamination in Pools

    Science.gov (United States)

    ... Communication (404) 639-3286 CDC study finds fecal contamination in pools A study of public pools done ... The E. coli is a marker for fecal contamination. Finding a high percentage of E. coli-positive ...

  18. Sediment transport through self-adjusting, bedrock-walled waterfall plunge pools

    Science.gov (United States)

    Scheingross, Joel S.; Lamb, Michael P.

    2016-05-01

    Many waterfalls have deep plunge pools that are often partially or fully filled with sediment. Sediment fill may control plunge-pool bedrock erosion rates, partially determine habitat availability for aquatic organisms, and affect sediment routing and debris flow initiation. Currently, there exists no mechanistic model to describe sediment transport through waterfall plunge pools. Here we develop an analytical model to predict steady-state plunge-pool depth and sediment-transport capacity by combining existing jet theory with sediment transport mechanics. Our model predicts plunge-pool sediment-transport capacity increases with increasing river discharge, flow velocity, and waterfall drop height and decreases with increasing plunge-pool depth, radius, and grain size. We tested the model using flume experiments under varying waterfall and plunge-pool geometries, flow hydraulics, and sediment size. The model and experiments show that through morphodynamic feedbacks, plunge pools aggrade to reach shallower equilibrium pool depths in response to increases in imposed sediment supply. Our theory for steady-state pool depth matches the experiments with an R2 value of 0.8, with discrepancies likely due to model simplifications of the hydraulics and sediment transport. Analysis of 75 waterfalls suggests that the water depths in natural plunge pools are strongly influenced by upstream sediment supply, and our model provides a mass-conserving framework to predict sediment and water storage in waterfall plunge pools for sediment routing, habitat assessment, and bedrock erosion modeling.

  19. Pool scrubbing and hydrodynamic experiments on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez-Jimenez, J.

    1995-01-01

    Plant analyses have shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination ofboundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanisms acting at the pool entrance. As a consequence, a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei the pool were measured and fitted to a long normal distribution. Particularly, size was found to be quite sensitive to inletgas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major highlights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  20. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  1. Pool scrubbing and hydrodynamic experiment on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-01-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  2. Turbulence model for melt pool natural convection heat transfer

    International Nuclear Information System (INIS)

    Kelkar, K.M.; Patankar, S.V.

    1994-01-01

    Under severe reactor accident scenarios, pools of molten core material may form in the reactor core or in the hemispherically shaped lower plenum of the reactor vessel. Such molten pools are internally heated due to the radioactive decay heat that gives rise to buoyant flows in the molten pool. The flow in such pools is strongly influenced by the turbulent mixing because the expected Rayleigh numbers under accidents scenarios are very high. The variation of the local heat flux over the boundaries of the molten pools are important in determining the subsequent melt progression behavior. This study reports results of an ongoing effort towards providing a well validated mathematical model for the prediction of buoyant flow and heat transfer in internally heated pool under conditions expected in severe accident scenarios

  3. Controls on Filling and Evacuation of Sediment in Waterfall Plunge Pools

    Science.gov (United States)

    Scheingross, J. S.; Lamb, M. P.

    2014-12-01

    Many waterfalls are characterized by the presence of deep plunge pools that experience periods of sediment fill and evacuation. These cycles of sediment fill are a first order control on the relative magnitude of lateral versus vertical erosion at the base of waterfalls, as vertical incision requires cover-free plunge pools to expose the bedrock floor, while lateral erosion can occur when pools are partially filled and plunge-pool walls are exposed. Currently, there exists no mechanistic model describing sediment transport through waterfall plunge pools, limiting our ability to predict waterfall retreat. To address this knowledge gap, we performed detailed laboratory experiments measuring plunge-pool sediment transport capacity (Qsc_pool) under varying waterfall and plunge-pool geometries, flow hydraulics, and sediment size. Our experimental plunge-pool sediment transport capacity measurements match well with a mechanistic model we developed which combines existing waterfall jet theory with a modified Rouse profile to predict sediment transport capacity as a function of water discharge and suspended sediment concentration at the plunge-pool lip. Comparing the transport capacity of plunge pools to lower gradient portions of rivers (Qsc_river) shows that, for transport limited conditions, plunge pools fill with sediment under modest water discharges when Qsc_river > Qsc_pool, and empty to bedrock under high discharges when Qsc_pool > Qsc_river. These results are consistent with field observations of sand-filled plunge pools with downstream boulder rims, implying filling and excavation of plunge pools over single-storm timescales. Thus, partial filling of waterfall plunge pools may provide a mechanism to promote lateral undercutting and retreat of waterfalls in homogeneous rock in which plunge-pool vertical incision occurs during brief large floods that expose bedrock, whereas lateral erosion may prevail during smaller events.

  4. Applications of Artificial Neural Network for the Prediction of Pool Boiling Curves

    International Nuclear Information System (INIS)

    Su, Guanghui; Fukuda, K.; Morita, K.

    2002-01-01

    Artificial neural network (ANN) has the advantage that the best-fit correlations of experimental data will no longer be necessary for predicting unknowns from the known parameters. The ANN was applied to predict the pool boiling curves in this paper. The database of experimental data presented by Berenson, Dhuga et al., and Bui and Dhir etc. were used in the analysis. The database is subdivided in two subsets. The first subset is used to train the network and the second one is used to test the network after the training process. The input parameters of the ANN are: wall superheat ΔT w , surface roughness, steady/transient heating/transient cooling, subcooling, Surface inclination and pressure. The output parameter is heat flux q. The proposed methodology allows us to achieve the accuracy that satisfies the user's convergence criterion and it is suitable for pool boiling curve data processing. (authors)

  5. Use of Flood Seasonality in Pooling-Group Formation and Quantile Estimation: An Application in Great Britain

    Science.gov (United States)

    Formetta, Giuseppe; Bell, Victoria; Stewart, Elizabeth

    2018-02-01

    Regional flood frequency analysis is one of the most commonly applied methods for estimating extreme flood events at ungauged sites or locations with short measurement records. It is based on: (i) the definition of a homogeneous group (pooling-group) of catchments, and on (ii) the use of the pooling-group data to estimate flood quantiles. Although many methods to define a pooling-group (pooling schemes, PS) are based on catchment physiographic similarity measures, in the last decade methods based on flood seasonality similarity have been contemplated. In this paper, two seasonality-based PS are proposed and tested both in terms of the homogeneity of the pooling-groups they generate and in terms of the accuracy in estimating extreme flood events. The method has been applied in 420 catchments in Great Britain (considered as both gauged and ungauged) and compared against the current Flood Estimation Handbook (FEH) PS. Results for gauged sites show that, compared to the current PS, the seasonality-based PS performs better both in terms of homogeneity of the pooling-group and in terms of the accuracy of flood quantile estimates. For ungauged locations, a national-scale hydrological model has been used for the first time to quantify flood seasonality. Results show that in 75% of the tested locations the seasonality-based PS provides an improvement in the accuracy of the flood quantile estimates. The remaining 25% were located in highly urbanized, groundwater-dependent catchments. The promising results support the aspiration that large-scale hydrological models complement traditional methods for estimating design floods.

  6. (Microbiological studies of small hot-bath-pools and hot-whirl-pools (author's transl))

    Energy Technology Data Exchange (ETDEWEB)

    Exner, M; Havenith, N

    1981-01-01

    Hot small bathing pools and hot whirl-pools have the following characteristics: small watervolume, thick squeeze of swimmers, high water temperature (37-40 degrees C) and small dimension of filters. By this, the quality of bathing-water is influenced detrimentally. To elaborate the hygienic problems, bathing-water samples were taken before, during and after the visiting-hours and were tested for facultative-pathogenic microorganisms. During this investigation E. coli was isolated in 25 degrees, Coliforms and Proteus species in 37.3%, P. aeruginosa in 36%, S. aureus in 26.3%, Enterococci in 42.3 %, Candida albicans in 3.6% and yeast totally in 8.3%.

  7. Environmental controls of C, N and P biogeochemistry in peatland pools.

    Science.gov (United States)

    Arsenault, Julien; Talbot, Julie; Moore, Tim R

    2018-08-01

    Pools are common in northern peatlands but studies have seldom focused on their nutrient biogeochemistry, especially in relation to their morphological characteristics and through seasons. We determined the environmental characteristics controlling carbon (C), nitrogen (N) and phosphorus (P) biogeochemistry in pools and assessed their evolution over the course of the 2016 growing season in a subboreal ombrotrophic peatland of eastern Canada. We showed that water chemistry variations in 62 pools were significantly explained by depth (81.9%) and the surrounding vegetation type (14.8%), but not by pool area or shape. Shallow pools had larger dissolved organic carbon (DOC) and total nitrogen (TN) concentrations and lower pH than deep pools, while pools surrounded by coniferous trees had more recalcitrant DOC than pools where vegetation was dominated by mosses. The influence of depth on pool biogeochemistry was confirmed by the seasonal survey of pools of different sizes with 47.1% of the variation in pool water chemistry over time significantly explained. Of this, 67.3% was explained by the interaction between time and pool size and 32.7% by pool size alone. P concentrations were small in all pools all summer long and combined with high N:P ratios, are indicative of P-limitation. Our results show that pool biogeochemistry is influenced by internal processes and highlight the spatial and temporal heterogeneity of nutrient biogeochemistry in ombrotrophic peatlands. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Reserve growth in oil pools of Alberta : model and forecast

    Energy Technology Data Exchange (ETDEWEB)

    Verma, M.; Cook, T. [United States Geological Survey, Denver, CO (United States). Central Region

    2010-09-15

    This paper presented a reserve growth study that was conducted on oil pools in Alberta, Canada. Historical oil reserve data were evaluated to assess the potential for future reserve growth in both pools and fields, and reserve growth models and functions were developed to better forecast hydrocarbon volumes. The study also considered the sensitivity of reserve growth to such factors as pool size, porosity, and oil gravity. From 1960 to 2005, the reported known recoverable oil in Alberta, excluding the Athabasca oil sands and including only pools with adequate data, increased from 4.2 to 13.9 billion barrels of oil (BBO). New discoveries contributed 3.7 BBO and reserve growth added 6 BBO. Most reserve growth occurred in pools with more than 125,000 barrels of oil. Light-oil pools account for most of the total known oil volume and consequently showed the lowest growth. Pools with greater than 30 percent porosity grew more than pools with lower porosity reservoirs. Oil field growth was found to be almost twice that of pool growth, possibly because the analysis evaluated fields with two or more pools discovered in different years. The growth in oil volumes in Alberta pools is projected to be about 454 million barrels of oil in the period from 2006 to 2010. Over a 25-year period, the cumulative reserve growth in Alberta oil pools was substantially lower than other major petroleum-producing regions, but the growth at the field level compares well. 8 refs., 2 tabs., 9 figs.

  9. Numerical modelling of methanol liquid pool fires

    Science.gov (United States)

    Prasad, Kuldeep; Li, Chiping; Kailasanath, K.; Ndubizu, Chuka; Ananth, Ramagopal; Tatem, P. A.

    1999-12-01

    The focus of this paper is on numerical modelling of methanol liquid pool fires. A mathematical model is first developed to describe the evaporation and burning of a two-dimensional or axisymmetric pool containing pure liquid methanol. Then, the complete set of unsteady, compressible Navier-Stokes equations for reactive flows are solved in the gas phase to describe the convection of the fuel gases away from the pool surface, diffusion of the gases into the surrounding air and the oxidation of the fuel into product species. Heat transfer into the liquid pool and the metal container through conduction, convection and radiation are modelled by solving a modified form of the energy equation. Clausius-Clapeyron relationships are invoked to model the evaporation rate of a two-dimensional pool of pure liquid methanol. The governing equations along with appropriate boundary and interface conditions are solved using the flux-corrected transport algorithm. Numerical results exhibit a flame structure that compares well with experimental observations. Temperature profiles and burning rates were found to compare favourably with experimental data from single- and three-compartment laboratory burners. The model predicts a puffing frequency of approximately 12 Hz for a 1 cm diameter methanol pool in the absence of any air co-flow. It is also observed that increasing the air co-flow velocity helps in stabilizing the diffusion flame, by pushing the vortical structures away from the flame region.

  10. Immunoparesis in newly diagnosed Multiple Myeloma patients

    DEFF Research Database (Denmark)

    Sorrig, Rasmus; Klausen, Tobias W.; Salomo, Morten

    2017-01-01

    Immunoparesis (hypogammaglobulinemia) is associated to an unfavorable prognosis in newly diagnosed Multiple myeloma (MM) patients. However, this finding has not been validated in an unselected population-based cohort. We analyzed 2558 newly diagnosed MM patients in the Danish Multiple Myeloma...

  11. Robotic cleaning of a spent fuel pool

    International Nuclear Information System (INIS)

    Roman, H.T.; Marian, F.A.; Silverman, E.B.; Barkley, V.P.

    1987-01-01

    Spent fuel pools at nuclear power plants are not cleaned routinely, other than by purifying the water that they contain. Yet, debris can collect on the bottom of a pool and should be removed prior to fuel transfer. At Public Service Electric and Gas Company's Hope Creek Nuclear Power Plant, a submersible mobile robot - ARD Corporation's SCAVENGER - was used to clean the bottom of the spent fuel pool prior to initial fuel loading. The robotic device was operated remotely (as opposed to autonomously) with a simple forward/reverse control, and it cleaned 70-80% of the pool bottom. This paper reports that a simple cost-benefit analysis shows that the robotic device would be less expensive, on a per mission basis, than other cleaning alternatives, especially if it were used for other similar cleaning operations throughout the plant

  12. Controlling pool depth during VAR of Alloy 718

    Science.gov (United States)

    Lopez, F.; Beaman, J.; Williamson, R.; Evans, D.

    2016-07-01

    A longtime goal of superalloy producers has been to control the geometry of the liquid pool in solidifying ingots. Accurate pool depth control at appropriate values is expected to result in ingots free of segregation defects. This article describes an industrial VAR experiment in which a 430mm (17 in) diameter Alloy 718 electrode was melted into a 510mm (20 in) ingot. In the experiment, the depth of the liquid pool at the mid-radius was controlled to three different set-points: 137 mm (nominal), 193 mm (deep) and 118 mm (shallow). At each level, the pool depth was marked by a power cutback of several minutes. The ingot was sectioned and longitudinal slices were cut out. Analysis of the photographed ingot revealed that accurate control was obtained for both the nominal and deep pool cases, while the third one was not conclusive.

  13. Estimated environmental radionuclide transfer and deposition into outdoor swimming pools

    International Nuclear Information System (INIS)

    Tagami, Kazumi; Nagata, Izumi; Sueki, Keisuke

    2014-01-01

    In 2011, a large radioactive discharge occurred at the Fukushima Daiichi nuclear power plant. This plant is located within a climatically temperate region where outdoor swimming pools are popular. Although it is relatively easy to decontaminate pools by refilling them with fresh water, it is difficult to maintain safe conditions given highly contaminated diurnal dust falls from the surrounding contaminated ground. Our objectives in this paper were to conduct daily radioactivity measurements, to determine the quantity of radioactive contaminants from the surrounding environment that invade outdoor pools, and to investigate the efficacy of traditional pool cleaners in removing radioactive contaminants. The depositions in the paper filterable particulates ranged from 0 to 62,5 Bq/m 2 /day, with the highest levels found in the southern Tohoku District containing Fukushima Prefecture and in the Kanto District containing Tokyo Metro. They were approximately correlated with the ground contamination. Traditional pool cleaners eliminated 99% of contaminants at the bottom of the pool, reducing the concentration to 41 Bq/m 2 after cleaning. Authors recommended the deposition or the blown radionuclides into outdoor swimming pools must be considered into pool regulations when the environments exactly polluted with radionuclides. - Highlights: • Deposition into outdoor swimming pool in a habitable areas estimated 72 Bq/m 2 /day. • More than 500 Bq/m 2 /day deposition will exceed our national guideline (10 Bq/l) of swimming pool. • Vacuum pool cleaner eliminates 99% radionuclides deposition

  14. HLM fuel pin bundle experiments in the CIRCE pool facility

    Energy Technology Data Exchange (ETDEWEB)

    Martelli, Daniele, E-mail: daniele.martelli@ing.unipi.it [University of Pisa, Department of Civil and Industrial Engineering, Pisa (Italy); Forgione, Nicola [University of Pisa, Department of Civil and Industrial Engineering, Pisa (Italy); Di Piazza, Ivan; Tarantino, Mariano [Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone (Italy)

    2015-10-15

    Highlights: • The experimental results represent the first set of values for LBE pool facility. • Heat transfer is investigated for a 37-pin electrical bundle cooled by LBE. • Experimental data are presented together with a detailed error analysis. • Nu is computed as a function of the Pe and compared with correlations. • Experimental Nu is about 25% lower than Nu derived from correlations. - Abstract: Since Lead-cooled Fast Reactors (LFR) have been conceptualized in the frame of GEN IV International Forum (GIF), great interest has focused on the development and testing of new technologies related to HLM nuclear reactors. In this frame the Integral Circulation Experiment (ICE) test section has been installed into the CIRCE pool facility and suitable experiments have been carried out aiming to fully investigate the heat transfer phenomena in grid spaced fuel pin bundles providing experimental data in support of European fast reactor development. In particular, the fuel pin bundle simulator (FPS) cooled by lead bismuth eutectic (LBE), has been conceived with a thermal power of about 1 MW and a uniform linear power up to 25 kW/m, relevant values for a LFR. It consists of 37 fuel pins (electrically simulated) placed on a hexagonal lattice with a pitch to diameter ratio of 1.8. The FPS was deeply instrumented by several thermocouples. In particular, two sections of the FPS were instrumented in order to evaluate the heat transfer coefficient along the bundle as well as the cladding temperature in different ranks of sub-channels. Nusselt number in the central sub-channel was therefore calculated as a function of the Peclet number and the obtained results were compared to Nusselt numbers obtained from convective heat transfer correlations available in literature on Heavy Liquid Metals (HLM). Results reported in the present work, represent the first set of experimental data concerning fuel pin bundle behaviour in a heavy liquid metal pool, both in forced and

  15. Macroinvertebrate community assembly in pools created during peatland restoration

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Lee E., E-mail: l.brown@leeds.ac.uk; Ramchunder, Sorain J.; Beadle, Jeannie M.; Holden, Joseph

    2016-11-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  16. Macroinvertebrate community assembly in pools created during peatland restoration

    International Nuclear Information System (INIS)

    Brown, Lee E.; Ramchunder, Sorain J.; Beadle, Jeannie M.; Holden, Joseph

    2016-01-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  17. Macroinvertebrate community assembly in pools created during peatland restoration.

    Science.gov (United States)

    Brown, Lee E; Ramchunder, Sorain J; Beadle, Jeannie M; Holden, Joseph

    2016-11-01

    Many degraded ecosystems are subject to restoration attempts, providing new opportunities to unravel the processes of ecological community assembly. Restoration of previously drained northern peatlands, primarily to promote peat and carbon accumulation, has created hundreds of thousands of new open water pools. We assessed the potential benefits of this wetland restoration for aquatic biodiversity, and how communities reassemble, by comparing pool ecosystems in regions of the UK Pennines on intact (never drained) versus restored (blocked drainage-ditches) peatland. We also evaluated the conceptual idea that comparing reference ecosystems in terms of their compositional similarity to null assemblages (and thus the relative importance of stochastic versus deterministic assembly) can guide evaluations of restoration success better than analyses of community composition or diversity. Community composition data highlighted some differences in the macroinvertebrate composition of restored pools compared to undisturbed peatland pools, which could be used to suggest that alternative end-points to restoration were influenced by stochastic processes. However, widely used diversity metrics indicated no differences between undisturbed and restored pools. Novel evaluations of restoration using null models confirmed the similarity of deterministic assembly processes from the national species pool across all pools. Stochastic elements were important drivers of between-pool differences at the regional-scale but the scale of these effects was also similar across most of the pools studied. The amalgamation of assembly theory into ecosystem restoration monitoring allows us to conclude with more certainty that restoration has been successful from an ecological perspective in these systems. Evaluation of these UK findings compared to those from peatlands across Europe and North America further suggests that restoring peatland pools delivers significant benefits for aquatic fauna by

  18. Sharing as risk pooling in a social dilemma experiment

    Directory of Open Access Journals (Sweden)

    Todd L. Cherry

    2015-03-01

    Full Text Available In rural economies with missing or incomplete markets, idiosyncratic risk is frequently pooled through informal networks. Idiosyncratic shocks, however, are not limited to private goods but can also restrict an individual from partaking in or benefiting from a collective activity. In these situations, a group must decide whether to provide insurance to the affected member. We describe results of a laboratory experiment designed to test whether a simple sharing institution can sustain risk pooling in a social dilemma with idiosyncratic risk. We tested whether risk could be pooled without a commitment device and, separately, whether effective risk pooling induced greater cooperation in the social dilemma. We found that even in the absence of a commitment device or reputational considerations, subjects voluntarily pooled risk, thereby reducing variance in individual earnings. In spite of effective risk pooling, however, cooperation in the social dilemma was unaffected.

  19. Softwareland Chronicles: A Software Development Meta-Process Proposal

    Directory of Open Access Journals (Sweden)

    Bolanos Sandro

    2016-05-01

    Full Text Available This paper presents the software development meta-process (SD-MP as a proposal to set up software projects. Within this proposal we offer conceptual elements that help solve the war of methodologies and processes in favor of an integrating viewpoint, where the main flaws associated with conventional and agile approaches are removed. Our newly developed software platform to support the meta-process is also presented together with three case studies involving projects currently in progress, where the framework proposed in SD-MP has been applied.

  20. Experimental Study on Boiling Crisis in Pool Boiling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Satbyoul; Kim, Hyungdae [Kyung Hee University, Yongin (Korea, Republic of)

    2016-10-15

    They postulated that failure in re-wetting of a dry patch by a cooling liquid is governed by microhydrodynamics near the wall. Chu et al. commonly observed that active coalescence of newly generated bubbles with preexisting bubbles results in a residual dry patch and prevents the complete rewetting of the dry patch, leading to CHF. In this work, to reveal the key physical mechanism of CHF during the rewetting process of a dry patch, dynamics of dry patches and thermal pattern of a boiling surface are simultaneously observed using TR and IR thermometry techniques. Local dynamics of dry patch and thermal pattern on a boiling surface in synchronized manner for both space and time using TR and IR thermometry were measured during pool boiling of water. Observation and quantitative examination of CHF was performed. - The hydrodynamic and thermal behaviors of irreversible dry patch were observed. The dry patches coalesce into a large dry patch and it locally dried out. Due to the failure of liquid rewetting, the dry patch is not completely rewetted, resulting in the burn out at which temperature is -140°C. - When temperature of a dry patch rises beyond the instantaneous nucleation temperature, several bubbles nucleate at the head of the advancing liquid meniscus and prevents the liquid front, and eventually the overheated dry patch remains alive after the departure of the massive bubble.

  1. Nuclear Insurance Pools: Worldwide Practice and Development

    International Nuclear Information System (INIS)

    Reitsma, S. M. S.

    1998-01-01

    The development of nuclear installations to produce electricity led to the establishment of Nuclear Insurance Pools and the introduction of international Conventions on Third Party Liability. Nuclear Pools offer both Third Party Liability insurance, reflecting the Conventions' principles, and other insurance products. They are market-wide, providing a facility for participation by insurers who could not otherwise write the insurance for the particularly sensitive nuclear risk. All acceptances are for the net retention of each Member without recourse to individual reinsurance protection. Common account reinsurance is arranged with other Nuclear Pools all over the world. Thus, a transparency is created, which ensures the highest degree of reinsurance security and imposes a known finite limit to each participating insurer's commitment. Therefore, Pool-members are prepared to make a greater commitment to nuclear risks than would be case where they felt uncertain as regards their total exposure following a significant loss. (author)

  2. Opportunities and challenges when pooling milk samples using ELISA

    DEFF Research Database (Denmark)

    Græsbøll, Kaare; Andresen, Lars Ole; Hisham Beshara Halasa, Tariq

    2017-01-01

    -positive samples by pooling. To illustrate this, the sensitivity of antibody ELISA on pooled samples of bovine milk for Salmonella Dublin, Mycobacterium avium spp. paratuberculosis, and bovine virus diarrhea was tested. For these milk assays, the analytical sensitivity decreased rapidly with increasing pool sizes...

  3. Microscopic bubble behaviour in suppression pool during wetwell venting

    Science.gov (United States)

    Zablackaite, G.; Nagasaka, H.; Kikura, H.

    2017-10-01

    During a severe accident PCV failure should be avoided and fission products inside PCV should be confined as much as possible. In order to minimize FPs release, Wetwell venting is conducted by releasing steam-non-condensable gas mixture carrying FPs from the Drywell to Suppression Pool. Steam is condensed by subcooled water in the pool, and most of FPs are retained into water. The removal of FP in the water pool is referred to as “Pool Scrubbing effect”. Hydrodynamic parameters of bubbles have impact on pool scrubbing effect. However, there is only few data available to evaluate quantitatively the bubble behaviour under depressurization and/or thermal stratification conditions. Series of experiments were conducted to evaluate the influence of temperature distribution, non-condensable gas content and pressure in the Wetwell on bubble behaviour. Bubbles were visualized using High Speed Camera and adopting shadowgraphy technique. Applying Particle Tracking Velocimetry, bubble velocity and size distribution were obtained from recorded images. Experimental results show that with increasing suppression pool temperature, bubbles reaching the pool surface decreased in size and traveling velocity became slower. In pressurized wetwell, bubble behaviour was similar to that in the heated up suppression pool case, although bubble parameters were similar to the low temperature case. Higher air content induced water surface movement and bubbles were smaller due to break up.

  4. Draft environmental assessment -- Test Area North pool stabilization project update

    International Nuclear Information System (INIS)

    1997-06-01

    The purpose of this Environmental Assessment (EA) is to update the ''Test Area North Pool Stabilization Project'' EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped form the Ea/FONSI issued May 6, 1996. The origin and nature of the TMI core debris and the proposed drying process are described and analyzed in detail in this EA. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN

  5. Liquid-liquid mixing by gas injection in a pool configuration

    International Nuclear Information System (INIS)

    Corradini, M.L.

    1994-02-01

    An experimental apparatus was designed and constructed to study the mixing process of two immiscible liquids, in a pool configuration, by bottom gas injection. The apparatus consisted of a vertical pyrex conduit of 15.2 centimeters of internal diameter. To the lower part of the conduit was attached a porous plate through which the gas was injected. The experiments were photographically recorded. The pictures were digitized and a method was developed to quantify the mixing region thickness. This method requires knowledge of the void fraction, for each liquid, as a function of the superficial gas velocity. Because of this, void fraction was measured for the bubbly and churn flow regimes, in a pool configuration for every liquid. A new correlation, based on the drift flux model, is proposed for void fraction as a function of superficial gas velocity. It has been observed that mixing can start either in bubbly or churn flow regimes, depending on the liquid pair properties. Three mechanistic models were derived to aid in correlating the data, two for bubbly flow and one for churn flow. A transition region between these two flow regimes, was deduced, but not directly measured. A set of correlations was developed from the models and it is proposed to be implemented in current codes that model Molten Core Concrete Interactions (MCCI). The implications that the present work has on MCCI have been described. It can be deduced that mixing between the oxidic and the metallic phases will occur during the interaction

  6. Beta-Binomial Model for the Detection of Rare Mutations in Pooled Next-Generation Sequencing Experiments.

    Science.gov (United States)

    Jakaitiene, Audrone; Avino, Mariano; Guarracino, Mario Rosario

    2017-04-01

    Against diminishing costs, next-generation sequencing (NGS) still remains expensive for studies with a large number of individuals. As cost saving, sequencing genome of pools containing multiple samples might be used. Currently, there are many software available for the detection of single-nucleotide polymorphisms (SNPs). Sensitivity and specificity depend on the model used and data analyzed, indicating that all software have space for improvement. We use beta-binomial model to detect rare mutations in untagged pooled NGS experiments. We propose a multireference framework for pooled data with ability being specific up to two patients affected by neuromuscular disorders (NMD). We assessed the results comparing with The Genome Analysis Toolkit (GATK), CRISP, SNVer, and FreeBayes. Our results show that the multireference approach applying beta-binomial model is accurate in predicting rare mutations at 0.01 fraction. Finally, we explored the concordance of mutations between the model and software, checking their involvement in any NMD-related gene. We detected seven novel SNPs, for which the functional analysis produced enriched terms related to locomotion and musculature.

  7. 48 CFR 28.304 - Risk-pooling arrangements.

    Science.gov (United States)

    2010-10-01

    ... CONTRACTING REQUIREMENTS BONDS AND INSURANCE Insurance 28.304 Risk-pooling arrangements. Agencies may establish risk-pooling arrangements. These arrangements are designed to use the services of the insurance industry for safety engineering and the handling of claims at minimum cost to the Government. The agency...

  8. Experimental study on heat pipe heat removal capacity for passive cooling of spent fuel pool

    International Nuclear Information System (INIS)

    Xiong, Zhenqin; Wang, Minglu; Gu, Hanyang; Ye, Cheng

    2015-01-01

    Highlights: • A passively cooling SFP heat pipe with an 8.2 m high evaporator was tested. • Heat removed by the heat pipe is in the range of 3.1–16.8 kW. • The heat transfer coefficient of the evaporator is 214–414 W/m 2 /K. • The heat pipe performance is sensitive to the hot water temperature. - Abstract: A loop-type heat pipe system uses natural flow with no electrically driven components. Therefore, such a system was proposed to passively cool spent fuel pools during accidents to improve nuclear power station safety especially for station blackouts such as those in Fukushima. The heat pipe used for a spent fuel pool is large due to the spent fuel pool size. An experimental heat pipe test loop was developed to estimate its heat removal capacity from the spent fuel pool during an accident. The 7.6 m high evaporator is heated by hot water flowing vertically down in an assistant tube with a 207-mm inner diameter. R134a was used as the potential heat pipe working fluid. The liquid R134a level was 3.6 m. The tests were performed for water velocities from 0.7 to 2.1 × 10 −2 m/s with water temperatures from 50 to 90 °C and air velocities from 0.5 m/s to 2.5 m/s. The results indicate significant heat is removed by the heat pipe under conditions that may occur in the spent fuel pool

  9. Generational differences among newly licensed registered nurses.

    Science.gov (United States)

    Keepnews, David M; Brewer, Carol S; Kovner, Christine T; Shin, Juh Hyun

    2010-01-01

    Responses of 2369 newly licensed registered nurses from 3 generational cohorts-Baby Boomers, Generation X, and Generation Y-were studied to identify differences in their characteristics, work-related experiences, and attitudes. These responses revealed significant differences among generations in: job satisfaction, organizational commitment, work motivation, work-to-family conflict, family-to-work conflict, distributive justice, promotional opportunities, supervisory support, mentor support, procedural justice, and perceptions of local job opportunities. Health organizations and their leaders need to anticipate intergenerational differences among newly licensed nurses and should provide for supportive working environments that recognize those differences. Orientation and residency programs for newly licensed nurses should be tailored to the varying needs of different generations. Future research should focus on evaluating the effectiveness of orientation and residency programs with regard to different generations so that these programs can be tailored to meet the varying needs of newly licensed nurses at the start of their careers. Copyright 2010 Mosby, Inc. All rights reserved.

  10. Indoor swimming pools. Humidity caused problems and suggested solutions

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    Reports have been received from across Canada on premature deterioration and other problems of indoor swimming pool buildings. This technical paper has been prepared to assist pool managers to solve these problems, which typically include leaking roofs, condensation on inside walls, peeling paint, efflorescence, rusting of metal elements, deterioration of concrete block structures, and high costs for pool heating. An effective insulation and vapor barrier system for a swimming pool roof is described, and the high relative humidity of the typical pool building is discussed as the primary cause of most problems. Proper sealing to cut down air infiltration is recommended, along with proper maintenance and painting. High energy costs are often due to low insulation values and to excessive ventilation used for decreasing the humidity. By using dehumidifiers capable of heat recovery, and by placing an insulating blanket on the pool after operating hours, it is shown that substantial cost savings are possible. 10 figs.

  11. Detection of 41Ar diffusion from a TRIGA pool

    International Nuclear Information System (INIS)

    Foss, Scott; Nelson, George

    1990-01-01

    Argon-41 levels in very low concentrations in the reactor room air can be inferred from the rate of escape from the pool water surface. The rate of Argon-41 diffusion from pool water to room air was determined by the measurement of the activity buildup in containers of air in contact with the pool surface. The Argon-41 concentration in each container was measured by gamma-ray spectrometry with a calibrated GeLi detector. At 100 KW power with the water temperature at 10 deg. Celsius the total release of Argon-41 was determined to be 3.5e10±15% atoms for 80 minutes of operation. The corresponding activity released from the pool was 98.6 microcuries, while the total activity produced in the pool was 4900 microcuries. The diffusion coefficient of Argon-41 from the pool water surface to the air at this temperature was measured to be 3.14e-14 sec-cm 2 . (author)

  12. Expanding the live kidney donor pool: ethical considerations regarding altruistic donors, paired and pooled programs.

    Science.gov (United States)

    Patel, Shaneel Rajendra; Chadha, Priyanka; Papalois, Vassilios

    2011-06-01

    In renal transplant, there is a well-known deficiency in organ supply relative to demand. Live donation provides superior results when compared with deceased donation including a better rate of graft success and fewer immunologic complications. This deficiency in organs leads to significant morbidity and mortality rates. Alternative avenues have been extensively explored that may expand the live donor pool. They include altruistic donation as well as paired and pooled exchange programs. Altruistic donation is a truly selfless act from a donor unknown to the recipient. Kidney paired donation involves 2 incompatible donor-recipient pairs swapping donors to produce compatibility. Pooled donation involves at least 2 pairs, and can take the form of domino chains in which altruistic input sets up a chain of transplants, in which each recipient's incompatible donor makes a donation for the next recipient. Despite application of these various methods, there lie extensive ethical issues surrounding them. Misconceptions frequently occur; for instance, the perceived benefit that donating an organ to a loved one is greater for a related donor than for an altruistic one. Additionally, it is frequently believed that immunologic incompatibility offers coerced donors liberation from surgery, and that overcoming these barriers by introducing exchange programs provides vulnerable donors less protection. This article explores these and other complex ethical issues surrounding the various methods of expanding the donor pool. The authors offer opinions that challenge the ethical issues and attempt to overcome those views that hinder progress in the field.

  13. Restoration of oligodendrocyte pools in a mouse model of chronic cerebral hypoperfusion.

    Directory of Open Access Journals (Sweden)

    Jamie McQueen

    Full Text Available Chronic cerebral hypoperfusion, a sustained modest reduction in cerebral blood flow, is associated with damage to myelinated axons and cognitive decline with ageing. Oligodendrocytes (the myelin producing cells and their precursor cells (OPCs may be vulnerable to the effects of hypoperfusion and in some forms of injury OPCs have the potential to respond and repair damage by increased proliferation and differentiation. Using a mouse model of cerebral hypoperfusion we have characterised the acute and long term responses of oligodendrocytes and OPCs to hypoperfusion in the corpus callosum. Following 3 days of hypoperfusion, numbers of OPCs and mature oligodendrocytes were significantly decreased compared to controls. However following 1 month of hypoperfusion, the OPC pool was restored and increased numbers of oligodendrocytes were observed. Assessment of proliferation using PCNA showed no significant differences between groups at either time point but showed reduced numbers of proliferating oligodendroglia at 3 days consistent with the loss of OPCs. Cumulative BrdU labelling experiments revealed higher numbers of proliferating cells in hypoperfused animals compared to controls and showed a proportion of these newly generated cells had differentiated into oligodendrocytes in a subset of animals. Expression of GPR17, a receptor important for the regulation of OPC differentiation following injury, was decreased following short term hypoperfusion. Despite changes to oligodendrocyte numbers there were no changes to the myelin sheath as revealed by ultrastructural assessment and fluoromyelin however axon-glial integrity was disrupted after both 3 days and 1 month hypoperfusion. Taken together, our results demonstrate the initial vulnerability of oligodendroglial pools to modest reductions in blood flow and highlight the regenerative capacity of these cells.

  14. LNG pool fire simulation for domino effect analysis

    International Nuclear Information System (INIS)

    Masum Jujuly, Muhammad; Rahman, Aziz; Ahmed, Salim; Khan, Faisal

    2015-01-01

    A three-dimensional computational fluid dynamics (CFD) simulation of liquefied natural gas (LNG) pool fire has been performed using ANSYS CFX-14. The CFD model solves the fundamental governing equations of fluid dynamics, namely, the continuity, momentum and energy equations. Several built-in sub-models are used to capture the characteristics of pool fire. The Reynolds-averaged Navier–Stokes (RANS) equation for turbulence and the eddy-dissipation model for non-premixed combustion are used. For thermal radiation, the Monte Carlo (MC) radiation model is used with the Magnussen soot model. The CFD results are compared with a set of experimental data for validation; the results are consistent with experimental data. CFD results show that the wind speed has significant contribution on the behavior of pool fire and its domino effects. The radiation contours are also obtained from CFD post processing, which can be applied for risk analysis. The outcome of this study will be helpful for better understanding of the domino effects of pool fire in complex geometrical settings of process industries. - Highlights: • Simulation of pool fire using computational fluid dynamics (CFD) model. • Integration of CFD based pool fire model with domino effect. • Application of the integrated CFD based domino effect analysis

  15. A method of measuring a molten metal liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M., Donaldson, A.D.

    1990-12-12

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figs.

  16. Automated management of engineering infrastructure of pools of different purpose

    Directory of Open Access Journals (Sweden)

    Shirokov Lev Alekseevich

    2016-10-01

    Full Text Available Pools play an important role in people’s life. They answer people’s demand in rest and improve their health. At the same time pools are rather important for industrial use, for example in construction industry. In order to solve different construction problems it is essential to investigate the influence of microclimatic parameters on construction materials and structures. For this aim pools are in demand as special test sites for construction materials and structures in different environmental conditions including the case of a direct water impact. The efficient use of pools presupposes the necessity of constant hydroclimatic contro: air humidity and temperature, water temperature, chemical composition of water and air. Classification of pools of different purposes is presented in the article. The author considers the main problems of operation of pools as objects with complicated air-and-water environment. The questions of maintaining optimal microclimatic parameters in a pool are considered. The necessity of use of the control system of a microclimate, its efficiency, profitability and social effect of its implementation is described. A mathematical model of the thermal mode of a pool area is constructed. The process of indoor temperature regulation in the pool is considered.

  17. Crust formation and its effect on the molten pool coolability

    Energy Technology Data Exchange (ETDEWEB)

    Park, R.J.; Lee, S.J.; Sim, S.K. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-09-01

    Experimental and analytical studies of the crust formation and its effect on the molten pool coolability have been performed to examine the crust formation process as a function of boundary temperatures as well as to investigate heat transfer characteristics between molten pool and overlying water in order to evaluate coolability of the molten pool. The experimental test results have shown that the surface temperature of the bottom plate is a dominant parameter in the crust formation process of the molten pool. It is also found that the crust thickness of the case with direct coolant injection into the molten pool is greater than that of the case with a heat exchanger. Increasing mass flow rate of direct coolant injection to the molten pool does not affect the temperature of molten pool after the crust has been formed in the molten pool because the crust behaves as a thermal barrier. The Nusselt number between the molten pool and the coolant of the case with no crust formation is greater than that of the case with crust formation. The results of FLOW-3D analyses have shown that the temperature distribution contributes to the crust formation process due to Rayleigh-Benard natural convection flow.

  18. Backfitting swimming pool reactors

    International Nuclear Information System (INIS)

    Roebert, G.A.

    1978-01-01

    Calculations based on measurements in a critical assembly, and experiments to disclose fuel element surface temperatures in case of accidents like stopping of primary coolant flow during full power operation, have shown that the power of the swimming pool type research reactor FRG-2 (15 MW, operating since 1967) might be raised to 21 MW within the present rules of science and technology, without major alterations of the pool buildings and the cooling systems. A backfitting program is carried through to adjust the reactor control systems of FRG-2 and FRG-1 (5 MW, housed in the same reactor hall) to the present safety rules and recommendations, to ensure FRG-2 operation at 21 MW for the next decade. (author)

  19. Flashing oscillation in pool water

    International Nuclear Information System (INIS)

    Takamasa, Tomoji; Kondo, Koichi; Hazuku, Tatsuya

    1996-01-01

    This paper presents an experimental study of high-pressure saturated water discharging into the pool water. The purpose of the experiment is to clarify the phenomena that occur in blow-down of high-pressure saturated water from the pressure vessel into the water-filled containment in the case of a wall-crack accident or a LOCA in an advanced reactor. The results revealed that a flashing oscillation (FO) occurs when high-pressure saturated water discharges into the pool water, under specified experimental settings. The range of the flashing oscillates between a point very close to and some distance from the vent hole. The pressures in the vent tube and pool water vary according to the flashing oscillation. The pressure oscillation and frequency of flashing position might be caused by the balancing action between the supply of saturated water, flashing at the control volume and its condensation on the steam-water interface. A linear analysis was conducted using a spherical flashing bubble model. The period of the flashing oscillation in the experiments can be explained by theoretical analysis

  20. Willingness to join and pay for the newly proposed social health insurance among teachers in Wolaita Sodo Town, South Ethiopia.

    Science.gov (United States)

    Agago, Tesfamichael Alaro; Woldie, Mirkuzie; Ololo, Shimeles

    2014-07-01

    Cost-sharing between beneficiaries and governments is critical to achieve universal health care coverage. To address this, Ethiopia is currently introducing Social Health Insurance. However, there has been limited evidence on willingness to join the newly proposed insurance scheme in the country. The purpose of this study is to assess willingness to join and pay for the scheme among teachers in Wolaita Sodo Town government educational institutions, South Ethiopia. A cross-sectional study was conducted from February 5 to March 10, 2012 on 335 teachers. Stratified simple random sampling technique was used and data were collected using structured interviewer administered questionnaire. Binary and multiple logistic regressions were used to estimate the crude and adjusted odds ratios for willingness to pay. Three hundred twenty-eight teachers participated in the study with response rate of 98%. About 55% of the teachers had never heard of any type of health insurance scheme. However, 74.4% of them were willing to pay for the suggested insurance scheme. About 47% of those who were willing to pay agreed to contribute greater than or equal to 4% of their monthly salaries. Willingness to pay was more likely among those who had heard about health insurance, had previous history of inability to pay for medical bills and achieved higher educational status. The majority of the teachers were willing to join social health insurance; however, adequate awareness creation and discussion should be made with all employees at various levels for the successful implementation of the scheme.

  1. A pooling-LiNGAM algorithm for effective connectivity analysis of fMRI data

    Directory of Open Access Journals (Sweden)

    Lele eXu

    2014-10-01

    Full Text Available The Independent Component Analysis - linear non-Gaussian acyclic model (LiNGAM, an algorithm that can be used to estimate the causal relationship among non-Gaussian distributed data, has the potential value to detect the effective connectivity of human brain areas. Under the assumptions that (a: the data generating process is linear, (b there are no unobserved confounders, and (c data have non-Gaussian distributions, LiNGAM can be used to discover the complete causal structure of data. Previous studies reveal that the algorithm could perform well when the data points being analyzed is relatively long. However, there are too few data points in most neuroimaging recordings, especially functional magnetic resonance imaging (fMRI, to allow the algorithm to converge. Smith’s study speculates a method by pooling data points across subjects may be useful to address this issue (Smith et al., 2011. Thus this study focus on validating Smith’s proposal of pooling data points across subjects for the use of LiNGAM, and this method is named as pooling-LiNGAM (pLiNGAM. Using both simulated and real fMRI data, our current study demonstrates the feasibility and efficiency of the pLiNGAM on the effective connectivity estimation.

  2. Vitamin D Pooling Project

    Science.gov (United States)

    The Vitamin D Pooling Project of Rarer Cancers brought together investigators from 10 cohorts to conduct a large prospective epidemiologic study of the association between vitamin D status and seven rarer cancers.

  3. The role of Gliadel wafers in the treatment of newly diagnosed GBM: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Xing WK

    2015-06-01

    Full Text Available Wei-kang Xing,1 Chuan Shao,2 Zhen-yu Qi,1 Chao Yang,1 Zhong Wang1 1Department of Neurosurgery, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 2Department of Neurosurgery, The Second Clinical Medical College of North Sichuan Medical College, Nanchong, Sichuan, People’s Republic of China Background: Standard treatment for high-grade glioma (HGG includes surgery followed by radiotherapy and/or chemotherapy. Insertion of carmustine wafers into the resection cavity as a treatment for malignant glioma is currently a controversial topic among neurosurgeons. Our meta-analysis focused on whether carmustine wafer treatment could significantly benefit the survival of patients with newly diagnosed glioblastoma multiforme (GBM.Method: We searched the PubMed and Web of Science databases without any restrictions on language using the keywords “Gliadel wafers”, “carmustine wafers”, “BCNU wafers”, or “interstitial chemotherapy” in newly diagnosed GBM for the period from January 1990 to March 2015. Randomized controlled trials (RCTs and cohort studies/clinical trials that compared treatments designed with and without carmustine wafers and which reported overall survival or hazard ratio (HR or survival curves were included in this study. Moreover, the statistical analysis was conducted by the STATA 12.0 software.Results: Six studies including two RCTs and four cohort studies, enrolling a total of 513 patients (223 with and 290 without carmustine wafers, matched the selection criteria. Carmustine wafers showed a strong advantage when pooling all the included studies (HR =0.63, 95% confidence interval (CI =0.49–0.81; P=0.019. However, the two RCTs did not show a statistical increase in survival in the group with carmustine wafer compared to the group without it (HR =0.51, 95% CI =0.18–1.41; P=0.426, while the cohort studies demonstrated a significant survival increase (HR =0.59, 95% CI =0.44–0.79; P<0.0001.Conclusion

  4. Pooled versus separate measurements of tree-ring stable isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dorado Linan, Isabel, E-mail: isabel@gfz-potsdam.de [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Gutierrez, Emilia, E-mail: emgutierrez@ub.edu [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Helle, Gerhard, E-mail: ghelle@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Heinrich, Ingo, E-mail: heinrich@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Andreu-Hayles, Laia, E-mail: laiandreu@ub.edu [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Tree-Ring Laboratory, Lamont-Doherty Earth Observatory of Columbia University, Palisades NY (United States); Planells, Octavi, E-mail: leocarpus@hotmail.com [Universitat de Barcelona, Departament d' Ecologia, Diagonal 645, 08028, Barcelona (Spain); Leuenberger, Markus, E-mail: leuenberger@climate.unibe.ch [Climate and Environmental Physics, Physics Institute, University of Bern, Sidlerstrasse 5, 3012 Bern (Switzerland); Oeschger Centre of Climate Change Research, University of Bern, Zaehringerstrasse 25, 3012 Bern (Switzerland); Buerger, Carmen, E-mail: buerger@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany); Schleser, Gerhard, E-mail: schleser@gfz-potsdam.de [German Centre for Geosciences, Climate Dynamics and Landscape Evolution, Dendro Laboratory, Telegrafenberg, 14473, Potsdam (Germany)

    2011-05-01

    {delta}{sup 13}C and {delta}{sup 18}O of tree rings contain time integrated information about the environmental conditions weighted by seasonal growth dynamics and are well established as sources of palaeoclimatic and ecophysiological data. Annually resolved isotope chronologies are frequently produced by pooling dated growth rings from several trees prior to the isotopic analyses. This procedure has the advantage of saving time and resources, but precludes from defining the isotopic error or statistical uncertainty related to the inter-tree variability. Up to now only a few studies have compared isotope series from pooled tree rings with isotopic measurements from individual trees. We tested whether or not the {delta}{sup 13}C and the {delta}{sup 18}O chronologies derived from pooled and from individual tree rings display significant differences at two locations from the Iberian Peninsula to assess advantages and constraints of both methodologies. The comparisons along the period 1900-2003 reveal a good agreement between pooled chronologies and the two mean master series which were created by averaging raw individual values (Mean) or by generating a mass calibrated mean (MassC). In most of the cases, pooled chronologies show high synchronicity with averaged individual samples at interannual scale but some differences also show up especially when comparing {delta}{sup 18}O decadal to multi-decadal variations. Moreover, differences in the first order autocorrelation among individuals may be obscured by pooling strategies. The lack of replication of pooled chronologies prevents detection of a bias due to a higher mass contribution of one sample but uncertainties associated with the analytical process itself, as sample inhomogeneity, seems to account for the observed differences. - Research Highlights: {yields} Pooled {delta}{sup 13}C and {delta}{sup 18}O chronologies are expected to be similar to the mean. {yields} Empirical pooled chronologies {delta}{sup 13}C and

  5. Pooled versus separate measurements of tree-ring stable isotopes

    International Nuclear Information System (INIS)

    Dorado Linan, Isabel; Gutierrez, Emilia; Helle, Gerhard; Heinrich, Ingo; Andreu-Hayles, Laia; Planells, Octavi; Leuenberger, Markus; Buerger, Carmen; Schleser, Gerhard

    2011-01-01

    δ 13 C and δ 18 O of tree rings contain time integrated information about the environmental conditions weighted by seasonal growth dynamics and are well established as sources of palaeoclimatic and ecophysiological data. Annually resolved isotope chronologies are frequently produced by pooling dated growth rings from several trees prior to the isotopic analyses. This procedure has the advantage of saving time and resources, but precludes from defining the isotopic error or statistical uncertainty related to the inter-tree variability. Up to now only a few studies have compared isotope series from pooled tree rings with isotopic measurements from individual trees. We tested whether or not the δ 13 C and the δ 18 O chronologies derived from pooled and from individual tree rings display significant differences at two locations from the Iberian Peninsula to assess advantages and constraints of both methodologies. The comparisons along the period 1900-2003 reveal a good agreement between pooled chronologies and the two mean master series which were created by averaging raw individual values (Mean) or by generating a mass calibrated mean (MassC). In most of the cases, pooled chronologies show high synchronicity with averaged individual samples at interannual scale but some differences also show up especially when comparing δ 18 O decadal to multi-decadal variations. Moreover, differences in the first order autocorrelation among individuals may be obscured by pooling strategies. The lack of replication of pooled chronologies prevents detection of a bias due to a higher mass contribution of one sample but uncertainties associated with the analytical process itself, as sample inhomogeneity, seems to account for the observed differences. - Research Highlights: → Pooled δ 13 C and δ 18 O chronologies are expected to be similar to the mean. → Empirical pooled chronologies δ 13 C and δ 18 O and the mean show a high synchronicity. → Pooled chronologies differ

  6. Suncatcher and cool pool. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, J.

    1981-03-01

    The Suncatcher is a simple, conical solar concentrating device that captures light entering clerestory windows and directs it onto thermal storage elements at the back of a south facing living space. The cone shape and inclination are designed to capture low angle winter sunlight and to reflect away higher angle summer sunlight. It is found that winter radiation through a Suncatcher window is 40 to 50% higher than through an ordinary window, and that the average solar fraction is 59%. Water-filled steal culvert pipes used for thermal storage are found to undergo less stratification, and thus to be more effective, when located where sunlight strikes the bottom rather than the top. Five Suncatcher buildings are described. Designs are considered for 32/sup 0/, 40/sup 0/ and 48/sup 0/ north latitude, and as the latitude increases, the inclination angle of the cone should be lowered. The Cool Pool is an evaporating, shaded roof pond which thermosiphons cool water into water-filled columns within a building. Preliminary experiments indicate that the best shade design has unimpeded north sky view, good ventilation, complete summer shading, a low architectural profile, and low cost attic vent lowers work. Another series of experiments established the satisfactory performance of the Cool Pool on a test building using four water-filled cylinders, two cylinders, and two cylinders connected to the Cool Pool through a heat exchanger. Although an unshaded pool cools better at night than a shaded one, daytime heat gain far offsets this advantage. A vinyl waterbag heat exchanger was developed for use with the Cool Pool. (LEW)

  7. Flow dynamics of volume-heated boiling pools

    International Nuclear Information System (INIS)

    Ginsberg, T.; Jones, O.C.; Chen, J.C.

    1979-01-01

    Safety analyses of fast breeder reactors require understanding of the two-phase fluid dynamic and heat transfer characteristics of volume-heated boiling pool systems. Design of direct contact three-phase boilers, of practical interest in the chemical industries also requires understanding of the fundamental two-phase flow and heat transfer behavior of volume boiling systems. Several experiments have been recently reported relevant to the boundary heat-loss mechanisms of boiling pool systems. Considerably less is known about the two-phase fluid dynamic behavior of such systems. This paper describes an experimental investigation of the steady-state flow dynamics of volume-heated boiling pool systems

  8. Laser surveillance systems for fuel storage pools

    International Nuclear Information System (INIS)

    Boeck, H.

    1985-06-01

    A Laser Surveillance System (LASSY) as a new safeguards device has been developed under the IAEA research contract No. 3458/RB at the Atominstitut Wien using earlier results by S. Fiarman. This system is designed to act as a sheet of light covering spent fuel assemblies in spent fuel storage pools. When movement of assemblies takes place, LASSY detects and locates the position of the movement in the pool and when interrogated, presents a list of pool positions and times of movement to the safeguards inspector. A complete prototype system was developed and built. Full scale tests showed the principal working capabilities of a LASSY underwater

  9. Thermophysical modeling of volatile fission product release from a debris pool

    International Nuclear Information System (INIS)

    Yun, J. I.; Suh, K. Y.; Kang, C. S.

    1999-01-01

    A model is described for fission product release from the debris pool in the lower plenum of the reactor pressure vessel. In the pool, turbulent natural convection flow is formed due to homogeneous internal heat generation. Using the best-known correlations, heat transfer at the curved bottom and the top of the pool may be calculated. Volatile fission product gases in the pool nucleate and diffuse to bubbles. Both the homogeneous nucleation and heterogeneous nucleation are considered. The bubble nucleation, growth, coalescence and loss due to rise is modeled pursuant to bubble dynamics. If the pressure and temperature of the pool are very high, homogeneous nucleation that accounts for effect of decrease in the pool pressure can occur. The effect of the bubble-to-pool interfacial tension and the pool pressure on the nucleation rate is investigated in this work

  10. Unmet information needs and limited health literacy in newly diagnosed breast cancer patients over the course of cancer treatment.

    Science.gov (United States)

    Halbach, Sarah Maria; Ernstmann, Nicole; Kowalski, Christoph; Pfaff, Holger; Pförtner, Timo-Kolja; Wesselmann, Simone; Enders, Anna

    2016-09-01

    To investigate unmet information needs in newly diagnosed breast cancer patients over the course of cancer treatment and its association with health literacy. We present results from a prospective, multicenter cohort study (PIAT). Newly diagnosed breast cancer patients (N=1060) were surveyed directly after breast cancer surgery, 10 and 40 weeks later. Pooled linear regression modeling was employed analyzing changes in unmet information needs over time and its association with health literacy. Unmet information needs on side effects and medication and medical examination results and treatment options were high and increased during the first 10 weeks after breast cancer surgery. Considering health promotion and social issues, unmet information needs started high and decreased during post-treatment. Patients with limited health literacy had higher unmet information needs. Our results indicate a mismatch in information provision and breast cancer patients' information needs. Patients with limited health literacy may be at a distinct disadvantage in having their information needs met over the course of breast cancer treatment. Strategies are needed to reduce unmet information needs in breast cancer patients considering treatment-phase and health literacy and thereby enable them to better cope with their diseases. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Review of steam jet condensation in a water pool

    International Nuclear Information System (INIS)

    Kim, Y. S.; Song, C. H.; Park, C. K.; Kang, H. S.; Jeon, H. G.; Yoon, Y. J.

    2002-01-01

    In the advanced nuclear power plants including APR1400, the SDVS is adopted to increase the plant safety using the concept of feed-and-bleed operation. In the case of the TLOFW, the POSRV located at the top of the pressurizer is expected to open due to the pressurization of the reactor coolant system and discharges steam and/or water mixture into the water pool, where the mixture is condensed. During the condensation of the mixture, thermal-hydraulic loads such as pressure and temperature variations are induced to the pool structure. For the pool structure design, such thermal-hydraulic aspects should be considered. Understanding the phenomena of the submerged steam jet condensation in a water pool is helpful for system designers to design proper pool structure, sparger, and supports etc. This paper reviews and evaluates the steam jet condensation in a water pool on the physical phenomena of the steam condensation including condensation regime map, heat transfer coefficient, steam plume, steam jet condensation load, and steam jet induced flow

  12. 76 FR 79262 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Order Granting Approval of Proposed...

    Science.gov (United States)

    2011-12-21

    ... as the Board committees' charters and the company's code of ethics, with a retail value of... proposed rule change to describe services offered by NASDAQ to certain newly listing companies on NASDAQ's... new Section IM-5900-7 to describe products that are offered to certain newly listing companies. As...

  13. Code Development of Radioactive Aerosol Scrubbing in Pool-Injection Zone

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyun Joung; Ha, Kwang Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Jang, Dong Soon [Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the injection zone. The developed code has been verified using the experimental results and evaluated parametrically on the input variables. In injection zone, the initial steam condensation was most effective mechanism for the aerosol removal, and the steam fraction and pool temperature were highly affected on the decontamination factor by initial steam condensation. The aerosol scrubbing code will be updated to evaluate the decontamination factor at rise zone and finally whole pool scrubber phenomena. If a severe accident occurs in a nuclear power plant (NPP), the aerosol and gaseous fission products might be produced in the reactor vessel, and then released to the environment after the containment failure. FCVS (Filtered Containment Venting System) is one of the severe accident mitigation systems for retaining the containment integrity by discharging the high-temperature and high-pressure fission products to the environment after passing through the filtration system. In general, the FCVS is categorized into two types, wet and dry types. The scrubbing pool could play an important role in the wet type FCVS because a large amount of aerosol is captured in the water pool. The pool scrubbing phenomena have been modelled and embedded in several computer codes, such as SPARC (Suppression Pool Aerosol Removal Code), BUSCA (BUbble Scrubbing Algorithm) and SUPRA (Suppression Pool Retention Analysis). These codes aim at simulating the pool scrubbing process and estimating the decontamination factors (DFs) of the radioactive aerosol and iodine gas in the water pool, which is defined as the ratio of initial mass of the specific radioactive material to final massy after passing through the water pool. The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the injection

  14. Pooling strategies for St Petersburg gamblers

    OpenAIRE

    Csörgö, Sandor; Simons, Gordon

    2006-01-01

    Peter offers to play exactly one St Petersburg game with each of [math] players, Paul [math] , [math] , Paul [math] , whose conceivable pooling strategies are described by all possible probability distributions [math] . Comparing infinite expectations, we characterize among all [math] those admissible strategies for which the pooled winnings, each distributed as [math] , yield a finite added value for each and every one of Paul [math] , [math] , Paul [math] in comparison with their individual...

  15. Swimming pool special; Zwembadspecial

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-05-15

    This issue includes a few articles and messages on the use of heat pump systems in swimming pools. [Dutch] Dit nummer bevat onder meer een paar artikelen over het gebruik van warmtepompsystemen in zwembaden.

  16. Establishment probability in newly founded populations

    Directory of Open Access Journals (Sweden)

    Gusset Markus

    2012-06-01

    Full Text Available Abstract Background Establishment success in newly founded populations relies on reaching the established phase, which is defined by characteristic fluctuations of the population’s state variables. Stochastic population models can be used to quantify the establishment probability of newly founded populations; however, so far no simple but robust method for doing so existed. To determine a critical initial number of individuals that need to be released to reach the established phase, we used a novel application of the “Wissel plot”, where –ln(1 – P0(t is plotted against time t. This plot is based on the equation P0t=1–c1e–ω1t, which relates the probability of extinction by time t, P0(t, to two constants: c1 describes the probability of a newly founded population to reach the established phase, whereas ω1 describes the population’s probability of extinction per short time interval once established. Results For illustration, we applied the method to a previously developed stochastic population model of the endangered African wild dog (Lycaon pictus. A newly founded population reaches the established phase if the intercept of the (extrapolated linear parts of the “Wissel plot” with the y-axis, which is –ln(c1, is negative. For wild dogs in our model, this is the case if a critical initial number of four packs, consisting of eight individuals each, are released. Conclusions The method we present to quantify the establishment probability of newly founded populations is generic and inferences thus are transferable to other systems across the field of conservation biology. In contrast to other methods, our approach disaggregates the components of a population’s viability by distinguishing establishment from persistence.

  17. The warm pool in the Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Vinayachandran, P.N.; Shetye, S.R.

    is larger and warmer, a peculiarity of the pool in the Indian Ocean is its seasonal variation. The surface area of the pool changes from 24 x 106 km2 in April to 8 x 106 km2 in September due to interaction with the southwest monsoon. The annual cycles of sea...

  18. Steam blowdown experiments with the condensation pool test rig

    International Nuclear Information System (INIS)

    Purhonen, H.; Puustinen, M.; Laine, J.; Raesaenen, A.; Kyrki-Rajamaeki, R.; Vihavainen, J.

    2005-01-01

    During a possible loss-of-coolant accident (Local) a large amount of non-condensable (nitrogen) and condensable (steam) gas is blown from the upper drywell of the containment to the condensation pool through the blowdown pipes at the boiling water reactors (BWRs). The wet well pool serves as the major heat sink for condensation of steam. The blowdown causes both dynamic and structural loads to the condensation pool. There might also be a risk that the gas discharging to the pool could push its way to the emergency core cooling systems (ECCS) and undermine their performance. (author)

  19. Simulation of pool scrubbing experiments using BUSCA

    International Nuclear Information System (INIS)

    Dehbi, A.; Guentay, S.

    1994-01-01

    BUSCA-PSI is a computer code which predicts the aerosol scrubbing taking place when gas bubbles containing fission products rise through stagnant pools of water after a postulated severe accident. A Lagrangian formulation is adopted to follow the path of a bubble as it rises toward the surface of the pool. The BUSCA model includes most aerosol removal mechanisms which are thought to be significant, namely: Jet Impaction at tile orifice, Convection/Diffusiophoresis during steam condensation, Thermophoresis, Sedimentation, Centrifugal Impaction during bubble rise, and Brownian Diffusion. The hydraulic modelling offers a variety of options for the initial globule volume, the stable bubble size, tile bubble rise velocity, and the bubble shape. The heat and mass transfer part of tile model uses correlations found in the relevant literature. BUSCA simulations were performed to determine the decontamination factor (DF) dependence on key aerosol and thermal hydraulic parameters. The decontamination factor increases with height, pool temperature subcooling, and steam content. The decontamination factor exhibits a parabolic dependence on the particle radius. At low particle sizes, the DF is high due to Brownian Diffusion which is the dominant removal mechanism. The DF hits a minimum and then increases with particle size as Centrifugal Impaction and Sedimentation become important. In separate calculations, BUSCA was used to the simulate the aerosol scrubbing experiments performed by EPRI. For cold pool tests, the predicted scrubbing efficiencies were in a good, conservative agreement with the data for both Tin and CsI, and the discrepancies were within the reported measurement errors. For hot pool tests, the code systematically underpredicted the scrubbing DF's; this is potentially due to condensation in the gas space above the pool, a situation not currently modelled by BUSCA. The code was also tested against data produced by the Tepco-Toshiba-Hitachi experiments. The

  20. Study on water evaporation rate from indoor swimming pools

    Directory of Open Access Journals (Sweden)

    Rzeźnik Ilona

    2017-01-01

    Full Text Available The air relative humidity in closed spaces of indoor swimming pools influences significantly on users thermal comfort and the stability of the building structure, so its preservation on suitable level is very important. For this purpose, buildings are equipped with HVAC systems which provide adequate level of humidity. The selection of devices and their technical parameters is made using the mathematical models of water evaporation rate in the unoccupied and occupied indoor swimming pool. In the literature, there are many papers describing this phenomena but the results differ from each other. The aim of the study was the experimental verification of published models of evaporation rate in the pool. The tests carried out on a laboratory scale, using model of indoor swimming pool, measuring 99cm/68cm/22cm. The model was equipped with water spray installation with six nozzles to simulate conditions during the use of the swimming pool. The measurements were made for conditions of sports pools (water temperature 24°C and recreational swimming pool (water temperature 34°C. According to the recommendations the air temperature was about 2°C higher than water temperature, and the relative humidity ranged from 40% to 55%. Models Shah and Biasin & Krumm were characterized by the best fit to the results of measurements on a laboratory scale.

  1. Peatland Open-water Pool Biogeochemistry: The Influence of Hydrology and Vegetation

    Science.gov (United States)

    Arsenault, J.; Talbot, J.; Moore, T. R.

    2017-12-01

    Peatland open-water pools are net sources of carbon to the atmosphere. However, their interaction with the surrounding peat remains poorly known. In a previous study, we showed that shallow pools are richer in nutrients than deep pools. While depth was the main driver of biogeochemistry variations across time and space, analyses also showed that pool's adjacent vegetation may have an influence on water chemistry. Our goal is to understand the relationship between the biogeochemistry of open-water pools and their surroundings in a subboreal ombrotrophic peatland of southern Quebec (Canada). To assess the influence of vegetation on pool water chemistry, we compare two areas covered with different types of vegetation: a forested zone dominated by spruce trees and an open area mostly covered by Sphagnum spp. To evaluate the direction of water (in or out of the pools), we installed capacitance water level probes in transects linking pools in the two zones. Wells were also installed next to each probe to collect peat pore water samples. Samples were taken every month during summer 2017 and analyzed for dissolved organic carbon, nitrogen and phosphorus, pH and specific UV absorbance. Preliminary results show differences in peat water chemistry depending on the dominant vegetation. In both zones, water levels fluctuations are disconnected between peat and the pools, suggesting poor horizontal water movement. Pool water chemistry may be mostly influenced by the immediate surrounding vegetation than by the local vegetation pattern. Climate and land-use change may affect the vegetation structure of peatlands, thus affecting pool biogeochemistry. Considering the impact of pools on the overall peatland capacity to accumulate carbon, our results show that more focus must be placed on pools to better understand peatland stability over time.

  2. The atmospheric wet pool: definition and comparison with the oceanic warm pool

    Institute of Scientific and Technical Information of China (English)

    ZHANG Caiyun; CHEN Ge

    2008-01-01

    The oceanic warm pool (OWP) defined by sea surface temperature (SST) is known as the "heat reservoir" in the ocean. The warmest portion in the ocean mirrors the fact that the wettest region with the largest accumulation of water vapor (WV) in the atmosphere, termed atmospheric wet pool (AWP), should be identified because of the well-known Clausius-Clapeyron relationship between SST and WV. In this study, we used 14-year simultaneous observations of WV and SST from January 1988 to December 2001 to define the AWP and investigate its coupling and co-variations with the OWP. The joint examination of the area variations, centroid locations, and zonal migrations of the AWP and OWP lead to a number of interesting findings. The results hopefully can contribute to our understanding of the air-sea interaction in general and characterization of El Nifio/La Nina events in particular.

  3. Loss of spent fuel pool cooling PRA: Model and results

    International Nuclear Information System (INIS)

    Siu, N.; Khericha, S.; Conroy, S.; Beck, S.; Blackman, H.

    1996-09-01

    This letter report documents models for quantifying the likelihood of loss of spent fuel pool cooling; models for identifying post-boiling scenarios that lead to core damage; qualitative and quantitative results generated for a selected plant that account for plant design and operational practices; a comparison of these results and those generated from earlier studies; and a review of available data on spent fuel pool accidents. The results of this study show that for a representative two-unit boiling water reactor, the annual probability of spent fuel pool boiling is 5 x 10 -5 and the annual probability of flooding associated with loss of spent fuel pool cooling scenarios is 1 x 10 -3 . Qualitative arguments are provided to show that the likelihood of core damage due to spent fuel pool boiling accidents is low for most US commercial nuclear power plants. It is also shown that, depending on the design characteristics of a given plant, the likelihood of either: (a) core damage due to spent fuel pool-associated flooding, or (b) spent fuel damage due to pool dryout, may not be negligible

  4. Infections Unlikely to be Spread Through Swimming Pools

    Science.gov (United States)

    ... Water Home Infections Unlikely to be Spread Through Swimming Pools Language: English (US) Español (Spanish) Recommend on ... included below. Infections Unlikely to be Spread by Swimming Pools Head Lice Head lice are unlikely to ...

  5. Regional variation in the biogeochemical and physical characteristics of natural peatland pools.

    Science.gov (United States)

    Turner, T Edward; Billett, Michael F; Baird, Andy J; Chapman, Pippa J; Dinsmore, Kerry J; Holden, Joseph

    2016-03-01

    Natural open-water pools are a common feature of northern peatlands and are known to be an important source of atmospheric methane (CH4). Pool environmental variables, particularly water chemistry, vegetation community and physical characteristics, have the potential to exert strong controls on carbon cycling in pools. A total of 66 peatland pools were studied across three regions of the UK (northern Scotland, south-west Scotland, and Northern Ireland). We found that within-region variability of pool water chemistry was low; however, for many pool variables measured there were significant differences between regions. PCA analysis showed that pools in SW Scotland were strongly associated with greater vegetative cover and shallower water depth which is likely to increase dissolved organic carbon (DOC) mineralisation rates, whereas pools in N Scotland were more open and deeper. Pool water DOC, particulate organic carbon and dissolved CH4 concentrations were significantly different between regions. Pools in Northern Ireland had the highest concentrations of DOC (mean=14.5 mg L(-1)) and CH4 (mean=20.6 μg C L(-1)). Chloride and sulphate concentrations were significantly higher in the pools in N Scotland (mean values 26.3 and 2.40 mg L(-1), respectively) than elsewhere, due to a stronger marine influence. The ratio of UV absorbance at 465 nm to absorbance at 665 nm for pools in Northern Ireland indicated that DOC was sourced from poorly humified peat, potentially increasing the bioavailability and mineralisation of organic carbon in pools compared to the pools elsewhere. This study, which specifically aims to address a lack of basic biogeochemical knowledge about pool water chemistry, clearly shows that peatland pools are highly regionally variable. This is likely to be a reflection of significant regional-scale differences in peatland C cycling. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Pressure supression pool thermal mixing

    International Nuclear Information System (INIS)

    Cook, D.H.

    1984-10-01

    A model is developed and verified to describe the thermal mixing that occurs in the pressure suppression pool (PSP) of a commercial BWR. The model is designed specifically for a Mark-I containment and is intended for use in severe accident sequence analyses. The model developed in this work produces space and time dependent temperature results throughout the PSP and is useful for evaluating the bulk PSP thermal mixing, the condensation effectiveness of the PSP, and the long-term containment integrity. The model is designed to accommodate single or multiple discharging T-quenchers, a PSP circumferential circulation induced by the residual heat removal system discharge, and the thermal stratification of the pool that occurs immediately after the relief valves close. The PSP thermal mixing is verified by comparing the model-predicted temperatures to experimental temperatures that were measured in an operating BWR suppression pool. The model is then used to investigate several PSP thermal mixing problems that include the time to saturate at full relief valve flow, the temperature response to a typical stuck open relief valve scenario, and the effect of operator rotation of the relief valve discharge point

  7. Pressure suppression pool thermal mixing

    International Nuclear Information System (INIS)

    Cook, D.H.

    1984-01-01

    A model is developed and verified to describe the thermal mixing that occurs in the pressure suppression pool (PSP) of a commercial BWR. The model is designed specifically for a Mark-I containment and is intended for use in severe accident sequence analyses. The model produces space and time dependent temperature results throughout the PSP and is useful for evaluating the bulk PSP thermal mixing, the condensation effectiveness of the PSP, and the long-term containment integrity. The model is designed to accommodate single or multiple discharging T-quenchers, a PSP circumferential circulation induced by the residual heat removal system discharge, and the thermal stratification of the pool that occurs immediately after the relief valves close. The PSP thermal mixing model is verified by comparing the model predicted temperatures to experimental temperatures that were measured in an operating BWR suppression pool. The model is then used to investigate several PSP thermal mixing problems that include the time to saturate at full relief valve flow, the temperature response to a typical stuck open relief valve scenario, and the effect of operator rotation of the relief valve discharge point

  8. Thermal analyses for the rack design with spent fuel pool during the loss of cooling accident

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, C-L.; Chen, Y-S.; Chen, B-Y., E-mail: clinyeh@iner.gov.tw, E-mail: yschen@iner.gov.tw, E-mail: onepicemine@iner.gov.tw [Inst. of Nuclear Energy Research, Taoyuan County, Taiwan (China); Tseng, Y-S., E-mail: ystseng@mx.nthu.edu.tw [National Tsing Hua Univ., Engineering and System Science, Hsinchu, Taiwan (China); Wei, W-C., E-mail: hn150456@iner.gov.tw [Inst. of Nuclear Energy Research, Taoyuan County, Taiwan (China)

    2014-07-01

    Alternative fuel arrangements separating the latest fuels discharge from the reactor core are proposed, such as the 1x4 configuration in which the hot assembly is surrounded by 4 assemblies with much lower decay heat. For the rack design in the BWR spent fuel pool design, the lateral flow is eliminated by solid walls. In this study, cooling enhancement of splitting fuel rack is investigated using Computational Fluid Dynamics (CFD). The fuels in the pool are modeled by porous medium. Separating the fuel rack by a distance of 10 cm can lower the peak cladding temperature and the natural convection between the fuels and then earns more response time for the site people to implement necessary mitigation actions. (author)

  9. Planning for the Management and Disposition of Newly Generated TRU Waste from REDC

    International Nuclear Information System (INIS)

    Coffey, D. E.; Forrester, T. W.; Krause, T.

    2002-01-01

    This paper describes the waste characteristics of newly generated transuranic waste from the Radiochemical Engineering and Development Center at the Oak Ridge National Laboratory and the basic certification structure that will be proposed by the University of Tennessee-Battelle and Bechtel Jacobs Company LLC to the Waste Isolation Pilot Plant for this waste stream. The characterization approach uses information derived from the active production operations as acceptable knowledge for the Radiochemical Engineering and Development Center transuranic waste. The characterization approach includes smear data taken from processing and waste staging hot cells, as well as analytical data on product and liquid waste streams going to liquid waste disposal. Bechtel Jacobs Company and University of Tennessee-Battelle are currently developing the elements of a Waste Isolation Pilot Plant-compliant program with a plan to be certified by the Waste Isolation Pilot Plant for shipment of newly generated transuranic waste in the next few years. The current activities include developing interface plans, program documents, and waste stream specific procedures

  10. Structural analysis of the reactor pool for the RRRP

    International Nuclear Information System (INIS)

    Alberro, J.G.; Abbate, A.D.

    2005-01-01

    The purpose of the present document is to describe the structural design of the Reactor Pool relevant to the RRRP (Replacement Research Reactor Project) for the Australian Nuclear Science and Technology Organisation. The structural analysis required coordinated design, engineering, analysis, and fabrication efforts. The pool has been designed, manufactured, and inspected following as guideline the ASME Boiler and Pressure Vessel Code, which defines the requirements for the pool to withstand hydrostatic and mechanical forces, ensuring its integrity throughout its lifetime. Standard off-the-shelf finite element programs (Nastran and Ansys codes) were used to evaluate the pool and further qualify the design and its construction. Both global and local effect analyses were carried out. The global analysis covers the structural integrity of the pool wall (6 mm thick) considering the different load states acting on it, namely hydrostatic pressure, thermal expansion, and seismic event. The local analysis evaluates the structural behaviour of the pool at specific points resulting from the interaction among components. It is confirmed that maximum stresses and displacements fall below the allowable values required by the ASME Boiler and Pressure Vessel Code. The water pressure analysis was validated by means of a hydrostatic test. (authors)

  11. PIV measurements of turbulent jet and pool mixing produced by a steam jet discharge in a subcooled water pool

    International Nuclear Information System (INIS)

    Choo, Yeon Jun; Song, Chul-Hwa

    2010-01-01

    This experimental research is on the fluid-dynamic features produced by a steam injection into a subcooled water pool. The relevant phenomena could often be encountered in water cooled nuclear power plants. Two major topics, a turbulent jet and the internal circulation produced by a steam injection, were investigated separately using a particle image velocimetry (PIV) as a non-intrusive optical measurement technique. Physical domains of both experiments have a two-dimensional axi-symmetric geometry of which the boundary and initial conditions can be readily and well defined. The turbulent jet experiments with the upward discharging configuration provide the parametric values for quantitatively describing a turbulent jet such as the self-similar velocity profile, central velocity decay, spreading rate, etc. And in the internal circulation experiments with the downward discharging configuration, typical flow patterns in a whole pool region are measured in detail, which reveals both the local and macroscopic characteristics of the mixing behavior in a pool. This quantitative data on the condensing jet-induced mixing behavior in a pool could be utilized as benchmarking for a CFD simulation of relevant phenomena.

  12. Experience on Maintenance of Thai Research Reactor's 'Small-Section' Pool

    International Nuclear Information System (INIS)

    Tippayakul, Chanatip

    2013-01-01

    The reactor pool of TRR-1/M1 has been used since 1962 when the reactor building was constructed. Periodic maintenance of the reactor pool has been conducted by cleaning the pool surface and re-painting with epoxy coating. The TRR-1/M1 pool basically consists of two sections referred as 'large-section' and 'small-section'. The latest re-painting activity of the 'large-section' pool was performed in 2006 but the 'small-section' pool had not been re-painted for more than 10 years. Therefore, to assure that the 'small-section' pool can maintain leak-proof condition, the re-painting of the 'small-section' pool was performed in the early 2012. A project team was organized specially for this project and a detailed execution plan was developed. The project activities include removing foreign objects and highly activated materials from the pool section, cleaning, inspecting, re-painting the pool surface and testing for water leaks. Preparation of the repainting activities had begun 2 years in advance. During the time, the reactor core had been relocated to operate in the large-section pool away from the working area in order to minimize radioactivity. The challenge of this project was to handle 4 sets of highly radioactive bolts and nuts which support the weight of the 'void tank' irradiation facility. These bolts and nuts were made from stainless steel and had been in the flux region since the installation of the 'void tank' irradiation facility approximately 30 years ago. Dose rate measurement at the contacts of these bolts and nuts were found to be in the range of 10 . 20 R/hr. The strategy to minimize the dose rate of the workers to conduct the pool repainting in the area was to remove the bolts and nuts and replace with new ones before entering the area. Special tools were improvised in order to remove the bolts and nuts under water. During the execution of the project, close radiation monitoring was performed by the radiation protection team. The project was conducted

  13. Phytobenthic communities of intertidal rock pools in the eastern islands of Azores and their relation to position on shore and pool morphology

    OpenAIRE

    Wallenstein, Francisco; Peres, Sara D.; Xavier, Emanuel D.; Neto, Ana I.

    2010-01-01

    This study aimed to characterize algal composition inside rock-pools from two islands of the Azores archipelago (São Miguel and Santa Maria) and relate it to shore height and pool morphology. Pools were categorized as upper, medium and lower intertidal according to the surrounding communities. Maximum depth and surface area were used to reflect morphology and qualitative sampling to evaluate algal species richness. PRIMER software assessed the similarity across islands, sites, shore height...

  14. 16 CFR 1633.5 - Prototype pooling and confirmation testing requirements.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Prototype pooling and confirmation testing... Prototype pooling and confirmation testing requirements. (a) Prototype pooling. One or more manufacturers may rely on a qualified prototype produced by another manufacturer or prototype developer provided...

  15. Non-electric applications of pool-type nuclear reactors

    International Nuclear Information System (INIS)

    Adamov, E.O.; Cherkashov, Yu.M.; Romenkov, A.A.

    1997-01-01

    This paper recommends the use of pool-type light water reactors for thermal energy production. Safety and reliability of these reactors were already demonstrated to the public by the long-term operation of swimming pool research reactors. The paper presents the design experience of two projects: Apatity Underground Nuclear Heating Plant and Nuclear Sea-Water Desalination Plant. The simplicity of pool-type reactors, the ease of their manufacturing and maintenance make this type of a heat source attractive to the countries without a developed nuclear industry. (author). 6 figs, 1 tab

  16. Effect of pool turbulence on direct contact condensation at a steam/water interface

    International Nuclear Information System (INIS)

    Jackson, J.D.; Zhao, C.L.; Doerffer, S.; Byrne, J.E.; Falaki, H.

    2000-01-01

    Measurements of direct contact condensation beat transfer have been made for the case where the process takes place at the horizontal interface between saturated steam and a pool of water in a vertical cylindrical test section. A submerged vertical jet of subcooled water was injected upwards on the axis to promote the condensation and water was withdrawn at the same rate from the bottom of the pool. In conjunction with the above study, measurements of the turbulent velocity fluctuations just below a free surface produced by the injection of a vertical submerged jet have been measured using hot film anemometry on an isothermal air-water test facility of similar geometry for similar flow conditions at ambient temperature. A correlation is proposed in terms of a Stanton number based on turbulent velocity fluctuation near the interface on the liquid-side. Our results are in good agreement with those of others for similar configurations when compared in terms of condensation Stanton number. (author)

  17. Assessment of Newly Proposed Clinical Criteria to Identify HNF1A MODY in Patients with an Initial Diagnosis of Type 1 or Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Malgorzata Grzanka

    2016-01-01

    Full Text Available The most common form of maturity-onset diabetes of the young (MODY is caused by mutations in the hepatocyte nuclear factor 1A (HNF1A gene. However, most HNF1A mutation-carriers are initially misdiagnosed with type 1 (T1DM or type 2 (T2DM diabetes mellitus; hence, they often receive nonoptimal treatment. The aim of our study was to test newly proposed clinical criteria for the identification of HNF1A MODY in patients with a diagnosis of T1DM or T2DM. To achieve this, the following criteria to preselect patients for screening were used: for T1DM: TDIR (total daily insulin requirement > 0.3 IU of insulin/kg and the percentage of basal insulin > 30% of TDIR; for T2DM: sulphonylurea- (SU- based oral treatment (monotherapy or combined with Metformin > 15 years and BMI < 30 kg/m2. We reviewed the clinical data of 140 patients with T1DM and 524 clinically diagnosed with T2DM. On the basis of these criteria, we found a HNF1A mutation in 1 out of 2 individuals with a diagnosis of T1DM and 1 out of 11 selected individuals with a diagnosis of T2DM. We believe that the simplicity of the proposed criteria might prove useful in clinical practice, as an alternative to more time-consuming classical diagnostic techniques.

  18. Assessment of Newly Proposed Clinical Criteria to Identify HNF1A MODY in Patients with an Initial Diagnosis of Type 1 or Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Grzanka, Malgorzata; Matejko, Bartlomiej; Szopa, Magdalena; Kiec-Wilk, Beata; Malecki, Maciej T; Klupa, Tomasz

    2016-01-01

    The most common form of maturity-onset diabetes of the young (MODY) is caused by mutations in the hepatocyte nuclear factor 1A (HNF1A) gene. However, most HNF1A mutation-carriers are initially misdiagnosed with type 1 (T1DM) or type 2 (T2DM) diabetes mellitus; hence, they often receive nonoptimal treatment. The aim of our study was to test newly proposed clinical criteria for the identification of HNF1A MODY in patients with a diagnosis of T1DM or T2DM. To achieve this, the following criteria to preselect patients for screening were used: for T1DM: TDIR (total daily insulin requirement) > 0.3 IU of insulin/kg and the percentage of basal insulin > 30% of TDIR; for T2DM: sulphonylurea- (SU-) based oral treatment (monotherapy or combined with Metformin) > 15 years and BMI < 30 kg/m(2). We reviewed the clinical data of 140 patients with T1DM and 524 clinically diagnosed with T2DM. On the basis of these criteria, we found a HNF1A mutation in 1 out of 2 individuals with a diagnosis of T1DM and 1 out of 11 selected individuals with a diagnosis of T2DM. We believe that the simplicity of the proposed criteria might prove useful in clinical practice, as an alternative to more time-consuming classical diagnostic techniques.

  19. Dry patch formed boiling and burnout in potassium pool boiling

    International Nuclear Information System (INIS)

    Michiyoshi, I.; Takenaka, N.; Takahashi, O.

    1986-01-01

    Experimental results are presented on dry patch formed boiling and burnout in saturated potassium pool boiling on a horizontal plane heater for system pressures from 30 to 760 torr and liquid levels from 5 to 50 mm. The dry patch formation occurs in the intermittent boiling which is often encountered when liquid alkali metals are used under relatively low pressure conditions. Burnout is caused from both continuous nucleate and dry patch formed boiling. The burnout heat flux together with nucleate boiling heat transfer coefficients are empirically correlated with system pressures. A model is also proposed to predict the minimum heat flux to form the dry patch. (author)

  20. Electricity prices and generator behaviour in gross pool electricity markets

    International Nuclear Information System (INIS)

    O'Mahoney, Amy; Denny, Eleanor

    2013-01-01

    Electricity market liberalisation has become common practice internationally. The justification for this process has been to enhance competition in a market traditionally characterised by statutory monopolies in an attempt to reduce costs to end-users. This paper endeavours to see whether a pool market achieves this goal of increasing competition and reducing electricity prices. Here the electricity market is set up as a sealed bid second price auction. Theory predicts that such markets should result with firms bidding their marginal cost, thereby resulting in an efficient outcome and lower costs to consumers. The Irish electricity system with a gross pool market experiences among the highest electricity prices in Europe. Thus, we analyse the Irish pool system econometrically in order to test if the high electricity prices seen there are due to participants bidding outside of market rules or out of line with theory. Overall we do not find any evidence that the interaction between generator and the pool in the Irish electricity market is not efficient. Thus, the pool element of the market structure does not explain the high electricity prices experienced in Ireland. - Highlights: • We consider whether a gross pool achieves competitive behaviour. • We analyse the Irish pool system econometrically. • Results indicate the Irish pool system appears to work efficiently. • Generators appear to be bidding appropriately

  1. Comparison of swimming pools alternative passive and active heating systems based on renewable energy sources in Southern Europe

    International Nuclear Information System (INIS)

    Katsaprakakis, Dimitris Al.

    2015-01-01

    This article examines different passive and active heating systems for swimming pools. The passive systems introduced in this article are: * The swimming pools' enclosure. * The placement of floating insulating covers on the pools' surfaces whenever they are not used. The examined active systems in this article are: * A biomass heater. * A biomass heater and solar collectors combi-system. * Vertical geothermal heat exchangers (GHE) co-operating with geothermal heat pumps (GHP). The methodology employed for the introduced systems' evaluation is the arithmetic computational simulation of the swimming pools' annual heating, using annual time series of averaged hourly values for the available solar radiation and the calculated pools' thermal power demand (heating loads). The dimensioning of the active systems aims at the maximisation of the heating production from R.E.S. (renewable energy sources). and the optimisation of the corresponding investments' economic indexes. The examined systems are evaluated technically and economically versus fundamental criteria. It is proved that significant reduction of the heating loads is achieved with the introduced passive systems. The reduced swimming pools' heating loads can be successfully covered by the proposed R.E.S. active systems. The fossil fuels consumption is eliminated. The corresponding investments' payback periods can be lower than 5 years. - Highlights: • The passive solar systems reduce the swimming pools heating loads more than 90%. • The examined active heating system exhibit payback periods lower than 3.5 years. • The energy saving is maximised with a biomass heater – solar collectors system. • Single biomass heaters exhibits the shortest payback period. • GHE–GHP can be used in cases of low solar radiation and lack of biomass fuels

  2. Mathematical modeling of the energy consumption of heated swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Le Bel, C.; Millette, J. [LTE Shawinigan, Shawinigan, PQ (Canada)

    2007-07-01

    A mathematical model was developed to estimate the water temperature of a residential swimming pool. The model can compare 2 different situations and, if local climatic conditions are known, it can accurately predict energy costs of the pool relative to the total energy consumption of the house. When used with the appropriate energy transfer coefficient and weather file, the model can estimate the water temperature of a residential swimming pool having specific characteristics, such as in-ground, above-ground, heated or non-heated. The model is suitable for determining residential loads. It can be applied to different pool types and sizes, for different water heating scenarios and different climatic regions. Data obtained from the monitoring of water temperature and electricity use of 57 residential swimming pools was used to validate the model. In addition, 5 above-ground pools were installed on the property of LTE Shawinigan to allow for a more detailed study of the parameters involved in the thermal balance of a pool. The mathematical model, based on a global heat transfer coefficient, can determine the effect of a solar blanket and the effect of water volume. 14 refs., 5 tabs., 11 figs.

  3. Mycobacterium arupense, Mycobacterium heraklionense, and a Newly Proposed Species, "Mycobacterium virginiense" sp. nov., but Not Mycobacterium nonchromogenicum, as Species of the Mycobacterium terrae Complex Causing Tenosynovitis and Osteomyelitis.

    Science.gov (United States)

    Vasireddy, Ravikiran; Vasireddy, Sruthi; Brown-Elliott, Barbara A; Wengenack, Nancy L; Eke, Uzoamaka A; Benwill, Jeana L; Turenne, Christine; Wallace, Richard J

    2016-05-01

    Mycobacterium terrae complex has been recognized as a cause of tenosynovitis, with M. terrae and Mycobacterium nonchromogenicum reported as the primary etiologic pathogens. The molecular taxonomy of the M. terrae complex causing tenosynovitis has not been established despite approximately 50 previously reported cases. We evaluated 26 isolates of the M. terrae complex associated with tenosynovitis or osteomyelitis recovered between 1984 and 2014 from 13 states, including 5 isolates reported in 1991 as M. nonchromogenicum by nonmolecular methods. The isolates belonged to three validated species, one new proposed species, and two novel related strains. The majority of isolates (20/26, or 77%) belonged to two recently described species: Mycobacterium arupense (10 isolates, or 38%) and Mycobacterium heraklionense (10 isolates, or 38%). Three isolates (12%) had 100% sequence identity to each other by 16S rRNA and 99.3 to 100% identity by rpoB gene region V sequencing and represent a previously undescribed species within the M. terrae complex. There were no isolates of M. terrae or M. nonchromogenicum, including among the five isolates reported in 1991. The 26 isolates were susceptible to clarithromycin (100%), rifabutin (100%), ethambutol (92%), and sulfamethoxazole or trimethoprim-sulfamethoxazole (70%). The current study suggests that M. arupense, M. heraklionense, and a newly proposed species ("M. virginiense" sp. nov.; proposed type strain MO-233 [DSM 100883, CIP 110918]) within the M. terrae complex are the major causes of tenosynovitis and osteomyelitis in the United States, with little change over 20 years. Species identification within this complex requires sequencing methods. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  4. Income pooling within families

    DEFF Research Database (Denmark)

    Bonke, Jens; Uldall-Poulsen, Hans

    This paper analyses the phenomenon of income-pooling by applying the Danish household expenditure survey, merged with authoritative register information. Responses to additional questions on income sharing among 1696 couples also allows us to analyses whether the intra-household distribution...

  5. Influence of Welding Parameters on the Weld Pool Dimensions and Shape in a TIG Configuration

    Directory of Open Access Journals (Sweden)

    Marine Stadler

    2017-04-01

    Full Text Available The weld pool shape created by the plasma arc interaction on a workpiece depends on many geometrical and physical parameters and on the operating conditions. Theoretical models are developed in such a way as to predict and to characterize the material. However, these models first need to be validated. Experimental results are hence proposed with parametric studies. Nevertheless, the interaction time is often short and the weld pool shape evolution not presented. In this work, the experimental setup and the diagnostic methods characterizing the workpiece are presented. The weld pool shape was evaluated versus time according to several parameters such as the current intensity value, the distance between the two electrodes, the cathode tip angle or the plasma gas nature. The results show that the depth-to-width ratio alone is not enough to compare the impact of the parameters. The analysis points out the great influence of the current intensity on the increase of the width and depth compared to the influence of the value of the cathode tip angle. The rise of the arc length leads to an increase of the power through a higher arc voltage; nevertheless, for distances of three and five millimeters and a characteristic time of the welding process of one second, this parameter has a weak influence on the energy transferred. The use of helium leads to a bigger volume of the weld pool due to an increase of width and depth.

  6. Health impact of disinfection by-products in swimming pools

    Directory of Open Access Journals (Sweden)

    Cristina M. Villanueva

    2012-12-01

    Full Text Available This article is focused on the epidemiological evidence on the health impacts related to disinfection by-products (DBPs in swimming pools, which is a chemical hazard generated as an undesired consequence to reduce the microbial pathogens. Specific DBPs are carcinogenic, fetotoxic and/or irritant to the airways according to experimental studies. Epidemiological evidence shows that swimming in pools during pregnancy is not associated with an increased risk of reproductive outcomes. An epidemiological study suggested an increased risk of bladder cancer with swimming pool attendance, although evidence is inconclusive. A higher prevalence of respiratory symptoms including asthma is found among swimming pool workers and elite swimmers, although the causality of this association is unclear. The body of evidence in children indicates that asthma is not increased by swimming pool attendance. Overall, the available knowledge suggests that the health benefits of swimming outweigh the potential health risks of chemical contamination. However, the positive effects of swimming should be enhanced by minimising potential risks.

  7. Characteristics of fission product release from a molten pool

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2001-01-01

    The volatile fission products are released from the debris pool, while the less volatile fission products tend to remain as condensed phases because of their low vapor pressure. The release of noble gases and the volatile fission products is dominated by bubble dynamics. The release of the less volatile fission products from the pool can be analyzed based on mass transport through a liquid with the convection flow. The physico-numerical models were orchestrated from existing submodels in various disciplines of engineering to estimate the released fraction of fission products from a molten pool. It was assumed that the pool has partially filled hemispherical geometry. For the high pool pressure, the diameter of the bubbles at detachment was calculated utilizing the Cole and Shulman correlation with the effect of system pressure. Sensitivity analyses were performed and results of the numerical calculations were compared with analysis results for the TMI-2 accident. (author)

  8. 13 CFR 120.631 - Suspension or termination of Pool Assembler.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Suspension or termination of Pool Assembler. 120.631 Section 120.631 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Pool Assemblers § 120.631 Suspension or termination of Pool Assembler. (a...

  9. Estimation of heat transfer and heat source in a molten pool

    Energy Technology Data Exchange (ETDEWEB)

    Yun, J.I.; Suh, K.Y.; Kang, C.S. [Seoul National Univ., Dept. of Nuclear Engineering (Korea, Republic of)

    2001-07-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine (29) elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry, 1.45 m in radius and 32,700 kg in mass. The change of pool geometry during the numerical calculation was neglected. The peak temperature sizably decreased by about 60 K as the fission products were released from the pool. (author)

  10. Estimation of heat transfer and heat source in a molten pool

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2001-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine (29) elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry, 1.45 m in radius and 32,700 kg in mass. The change of pool geometry during the numerical calculation was neglected. The peak temperature sizably decreased by about 60 K as the fission products were released from the pool. (author)

  11. Conditional estimation of local pooled dispersion parameter in small-sample RNA-Seq data improves differential expression test.

    Science.gov (United States)

    Gim, Jungsoo; Won, Sungho; Park, Taesung

    2016-10-01

    High throughput sequencing technology in transcriptomics studies contribute to the understanding of gene regulation mechanism and its cellular function, but also increases a need for accurate statistical methods to assess quantitative differences between experiments. Many methods have been developed to account for the specifics of count data: non-normality, a dependence of the variance on the mean, and small sample size. Among them, the small number of samples in typical experiments is still a challenge. Here we present a method for differential analysis of count data, using conditional estimation of local pooled dispersion parameters. A comprehensive evaluation of our proposed method in the aspect of differential gene expression analysis using both simulated and real data sets shows that the proposed method is more powerful than other existing methods while controlling the false discovery rates. By introducing conditional estimation of local pooled dispersion parameters, we successfully overcome the limitation of small power and enable a powerful quantitative analysis focused on differential expression test with the small number of samples.

  12. DATA-POOL : a direct-access data base for large-scale nuclear codes

    International Nuclear Information System (INIS)

    Yamano, Naoki; Koyama, Kinji; Naito, Yoshitaka; Minami, Kazuyoshi.

    1991-12-01

    A direct-access data base DATA-POOL has been developed for large-scale nuclear codes. The data can be stored and retrieved with specifications of simple node names, by using the DATA-POOL access package written in the FORTRAN 77 language. A management utility POOL for the DATA-POOL is also provided. A typical application of the DATA-POOL is shown to the RADHEAT-V4 code system developed for performing safety analyses of radiation shielding. Many samples and error messages are also noted to apply the DATA-POOL for the other code systems. This report is provided for a manual of DATA-POOL. (author)

  13. Pool boiling with high heat flux enabled by a porous artery structure

    Science.gov (United States)

    Bai, Lizhan; Zhang, Lianpei; Lin, Guiping; Peterson, G. P.

    2016-06-01

    A porous artery structure utilizing the concept of "phase separation and modulation" is proposed to enhance the critical heat flux of pool boiling. A series of experiments were conducted on a range of test articles in which multiple rectangular arteries were machined directly into the top surface of a 10.0 mm diameter copper rod. The arteries were then covered by a 2.0 mm thickness microporous copper plate through silver brazing. The pool wall was fabricated from transparent Pyrex glass to allow a visualization study, and water was used as the working fluid. Experimental results confirmed that the porous artery structure provided individual flow paths for the liquid supply and vapor venting, and avoided the detrimental effects of the liquid/vapor counter flow. As a result, a maximum heat flux of 610 W/cm2 over a heating area of 0.78 cm2 was achieved with no indication of dryout, prior to reaching the heater design temperature limit. Following the experimental tests, the mechanisms responsible for the boiling critical heat flux and performance enhancement of the porous artery structure were analyzed.

  14. Proposal for a verification facility of ADS in China

    International Nuclear Information System (INIS)

    Guan Xialing; Luo Zhanglin

    1999-01-01

    The concept, general layout and some specifications of a proposed verification facility of the accelerator driven radioactive clean nuclear power system (AD-RCNPS) in China are described. It is composed of a 150 MeV/3 mA low energy accelerator, a swimming pool reactor and some basic research facilities. The 150 MeV accelerator consists of an ECR proton source, LEBT, RFQ, CCDTL and SCC. As the sub-critical reactor, the swimming pool reactor is an existing research reactor at the China Institute of Atomic Energy, whose maximum output power is 3.5 MW. The effect of the instability of proton beam and possibility of simulation tests on the verification facility have been analysed. (author)

  15. Proposal for a verification facility of ADS in China

    International Nuclear Information System (INIS)

    Guan Xialing; Luo Zhanglin

    2000-01-01

    The concept, the general layout and some specifications of a proposed verification facility of the accelerator driven radioactive clean nuclear power system (AD-RCNPS) in China has been described. It is composed of a 150 MeV/3 mA low energy accelerator, a swimming pool reactor and some basic research facility. The 150 MeV accelerator consists of an ECR proton source, LEBT, RFQ, CCDTL and SCC. As the sub-critical reactor, the swimming pool reactor is an existing research reactor in China Institute of Atomic Energy, its maximum output power is 3.5 MW. The effect of the instability of proton beam and possibility of simulation test on the verification facility have been analyzed

  16. Seasonal variation in Chironomid emergence from coastal pools

    Directory of Open Access Journals (Sweden)

    Alexander T. Egan

    2015-07-01

    Full Text Available Understanding the phenology of emergences can be useful in determining seasonal chironomid life cycle patterns, which are often influenced by ice cover and temperature in cold climates. Lake Superior is the largest lake in North America and with a mean surface temperature of 3.9 °C influences regional climate. Coastal pools at Isle Royale, a wilderness archipelago in the northern part of the lake, occur in dense patches on low-gradient volcanic bedrock between the lakeshore and forest, creating variable microhabitats for Chironomidae. Four sites were sampled monthly from April to October, 2010. Surface-floating pupal exuviae were collected from a series of pools in two zones: a lower zone near the lake influenced by wave splash, and an upper zone near the forest and influenced by upland runoff. We used Jaccard’s and Whittaker’s diversity indexes to test community similarity across months. Temperature loggers in pools collected hourly readings for most of the study. Assemblage emergences were stable in upper pools, with significant similarity across late spring and summer months. Assemblages were seasonally variable in lower pools, with significant dissimilarity across spring, summer, and fall months. Few species in either zone were unique to spring or fall months. However, many summer species in the splash zone had a narrow emergence period occurring during calm weather following distinct increases in mean water temperature. Regardless of input of cold lake water to the lower zone, pools from both zones generally had corresponding temperature trends.

  17. Sodium/water pool-deposit bed model of the CONACS code

    International Nuclear Information System (INIS)

    Peak, R.D.

    1983-01-01

    A new Pool-Bed model of the CONACS (Containment Analysis Code System) code represents a major advance over the pool models of other containment analysis code (NABE code of France, CEDAN code of Japan and CACECO and CONTAIN codes of the United States). This new model advances pool-bed modeling because of the number of significant materials and processes which are included with appropriate rigor. This CONACS pool-bed model maintains material balances for eight chemical species (C, H 2 O, Na, NaH, Na 2 O, Na 2 O 2 , Na 2 CO 3 and NaOH) that collect in the stationary liquid pool on the floor and in the desposit bed on the elevated shelf of the standard CONACS analysis cell

  18. Natural convection heat transfer in the molten metal pool

    International Nuclear Information System (INIS)

    Park, R.J.; Kim, S.B.; Kim, H.D.; Choi, S.M.

    1997-01-01

    Analytical studies using the FLOW-3D computer program have been performed on natural convection heat transfer of a high density molten metal pool, in order to evaluate the coolability of the corium pool. The FLOW-3D results on the temperature distribution and the heat transfer rate in the molten metal pool region have been compared and evaluated with the experimental data. The FLOW-3D results have shown that the developed natural convection flow contributes to the solidified crust formation of the high density molten metal pool. The present FLOW-3D results, on the relationship between the Nusselt number and the Rayleigh number in the molten metal pool region, are more similar to the calculated results of Globe and Dropkin's correlation than any others. The natural convection heat transfer in the low aspect ratio case is more substantial than that in the high aspect ratio case. The FLOW-3D results, on the temperature profile and on the heat transfer rate in the molten metal pool region, are very similar to the experimental data. The heat transfer rate of the internal heat generation case is higher than that of the bottom heating case at the same heat supply condition. (author)

  19. Measurement of argon concentrations in a TRIGA Mark-III pool

    Energy Technology Data Exchange (ETDEWEB)

    Simms, R [California State University, Northridge, CA (United States)

    1974-07-01

    Argon-41, the principal radioactive effluent from a pool type reactor during normal operation, is produced by the {sup 40}A (n,{gamma}) reaction. The reactant, {sup 40}A, is introduced into the pool water by contact with the air. Reduction in radioactive argon release can be accomplished by reducing the concentration of dissolved {sup 40}A and retaining the {sup 41}A within the pool. However, little data were available concerning the mechanisms of argon introduction, production, retention, and release from a reactor pool. Experiments have therefore been performed at the Torrey Pines TRIGA Mark-III Reactor to develop techniques to sample dissolved argon and to provide data on argon concentrations in the pool for release modeling studies. Significant results for argon dissolved at different pool depths can only be obtained if the water samples are sealed at the point of collection. A special handling tool was developed to perform this remote operation. Pool samples were counted for {sup 41}A soon after collection with a NaI spectrometer. After allowing one day for decay of {sup 41}A, the concentration of {sup 40}A in the water sample was determined by neutron activation analysis. In each case, the 1.29 MeV gamma-ray peak of {sup 41}A was used. Interference from the 1.37 MeV {sup 24}Na peak was considered and its effect subtracted after determining {sup 24}Na content from the 2.75 MeV {sup 24}Na peak and a sodium standard. A Ge(Li) detector was tried and found to eliminate the problem, but it introduced an unacceptable geometrical effect dependent on bubble size within the sample bottles. Samples were taken from the 27 ft deep TRIGA pool at various locations. Results were obtained for samples taken on several different days along the same vertical line about 3-1/2 ft from the reactor centerline. Temperature measurements along this vertical traverse indicated a sharp temperature gradient at about 15 ft below the surface ({approx}6 ft above the top of the reactor). The

  20. Mathematical-programming approaches to test item pool design

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; van der Linden, Willem J.; Ariel, A.

    2002-01-01

    This paper presents an approach to item pool design that has the potential to improve on the quality of current item pools in educational and psychological testing andhence to increase both measurement precision and validity. The approach consists of the application of mathematical programming

  1. Horizontal above-rack pool storage

    International Nuclear Information System (INIS)

    Moscardini, R.L.

    1993-08-01

    This report describes a unique method for storing spent, six year out of core, fuel at a prototypical PWR nuclear power station. The study describes a conceptual design, with favorable structural, thermal and criticality technical evaluations. However, economic considerations and licensing risks are judged to be less favorable. The concept study prescribes a fuel over fuel arrangement in an existing Spent Fuel Pool (SFP) with full maintenance of ALARA principles. This concept study is specific to a prototypical pool design, but may easily be projected to other nuclear facilities with other SFP conditions. For the prototypical PWR, the conceptual fuel bridge design will store over 200 additional fuel assemblies without significant facility modifications and for an indefinite time period

  2. Pool swell sub-scale testing and code comparison

    International Nuclear Information System (INIS)

    Elisson, K.

    1981-01-01

    The main objective of the experiment was to investigate the pool swell dynamics in general and the forces on the lowered central part of the diaphragm between drywell and wetwell in particular. Apart from the high speed camera pressure transducers and strain gauges were used to monitor the transient. Data was recorded on a 14 channel FM recorder and then digitalised and plotted. In total more than one hundred tests were performed including parametric variations of for example geometry, break flow, initial drywell pressure and initial water level. In parallel to this experiment pool swell calculations have been performed with the computer codes COPTA and STEALTH. COPTA which is a lumped mass code for pressure suppression containment analysis has a slug pool swell mode. STEALTH which is a general purpose lagrangian hydrodynamics code has been used in a 2-D axisymmetric version. The STEALTH code has been used to calculate the radial variations in the vertical displacement and velocity of the pool surface and to predict the load on the lowered central part of the diaphragm. A comparison between the calculations and the experimental data indicates that both codes are sufficiently correct in their description of the pool swell transient. (orig.)

  3. Validation of Effective Models for Simulation of Thermal Stratification and Mixing Induced by Steam Injection into a Large Pool of Water

    Directory of Open Access Journals (Sweden)

    Hua Li

    2014-01-01

    Full Text Available The Effective Heat Source (EHS and Effective Momentum Source (EMS models have been proposed to predict the development of thermal stratification and mixing during a steam injection into a large pool of water. These effective models are implemented in GOTHIC software and validated against the POOLEX STB-20 and STB-21 tests and the PPOOLEX MIX-01 test. First, the EHS model is validated against STB-20 test which shows the development of thermal stratification. Different numerical schemes and grid resolutions have been tested. A 48×114 grid with second order scheme is sufficient to capture the vertical temperature distribution in the pool. Next, the EHS and EMS models are validated against STB-21 test. Effective momentum is estimated based on the water level oscillations in the blowdown pipe. An effective momentum selected within the experimental measurement uncertainty can reproduce the mixing details. Finally, the EHS-EMS models are validated against MIX-01 test which has improved space and time resolution of temperature measurements inside the blowdown pipe. Excellent agreement in averaged pool temperature and water level in the pool between the experiment and simulation has been achieved. The development of thermal stratification in the pool is also well captured in the simulation as well as the thermal behavior of the pool during the mixing phase.

  4. Observations of Cold Pool Properties during GoAmazon2014/5

    Science.gov (United States)

    Mayne, S. L.; Schumacher, C.; MacDonald, L.; Turner, D. D.

    2017-12-01

    Convectively generated cold pools are instrumental in both the development of the sub-cloud layer and the organization of deep convection. Despite this, analyses of cold pools in the tropics are constrained by a lack of observational data; insight into the phenomena therefore relies heavily on numerical models. GoAmazon2014/5, a 2-year DOE-sponsored field campaign centered on Manacapuru, Brazil in the central Amazon, provides a unique opportunity to characterize tropical cold pools and allows for the comparison of observational data with theoretical results from model cold pool simulations and parameterizations. This investigation analyzes radar, disdrometer, and profiler measurements at the DOE mobile facility site to study tropical cold pool characteristics. The Brazilian military (SIPAM) operational S-band radar in Manaus is used to provide a broad context of convective systems, while measurements from Parsivel disdrometers are used to assess drop-size distributions (DSDs) at the surface. A unique aspect of this research is the use of the Atmospheric Emitted Radiance Interferometer (AERI) instrument, which utilizes down-welling IR measurements to obtain vertical profiles of thermodynamic quantities such as temperature and water vapor in the lowest few km of the atmosphere. Combined with surface observations and sounding data, these datasets will result in a thorough investigation of the horizontal and vertical characteristics of cold pools over the tropical rain forest. Preliminary analyses of 20 events reveal a mean cold pool height of 220 m and a mean radius of approximately 8.5 km. The average cold pool experienced a temperature (specific humidity) decrease of approximately 1 K (0.4 g/kg) at the surface. The temperature decrease is consistent with modeling studies and limited observations from previous studies over the tropics. The small decrease in specific humidity is attributed to the high moisture content within the cold pools. AERI retrievals of

  5. Sustainability of common pool resources.

    Science.gov (United States)

    Timilsina, Raja Rajendra; Kotani, Koji; Kamijo, Yoshio

    2017-01-01

    Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as "capitalism," affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepalese areas: (i) rural (non-capitalistic) and (ii) urban (capitalistic) areas. We find that a proportion of prosocial individuals in urban areas is lower than that in rural areas, and urban residents deplete resources more quickly than rural residents. The composition of proself and prosocial individuals in a group and the degree of capitalism are crucial in that an increase in prosocial members in a group and the rural dummy positively affect resource sustainability by 65% and 63%, respectively. Overall, this paper shows that when societies move toward more capitalistic environments, the sustainability of common pool resources tends to decrease with the changes in individual preferences, social norms, customs and views to others through human interactions. This result implies that individuals may be losing their coordination abilities for social dilemmas of resource sustainability in capitalistic societies.

  6. Single-Track Melt-Pool Measurements and Microstructures in Inconel 625

    Science.gov (United States)

    Ghosh, Supriyo; Ma, Li; Levine, Lyle E.; Ricker, Richard E.; Stoudt, Mark R.; Heigel, Jarred C.; Guyer, Jonathan E.

    2018-02-01

    We use single-track laser melting experiments and simulations on Inconel 625 to estimate the dimensions and microstructure of the resulting melt pool. Our work is based on a design-of-experiments approach which uses multiple laser power and scan speed combinations. Single-track experiments generated melt pools of certain dimensions that showed reasonable agreement with our finite-element calculations. Phase-field simulations were used to predict the size and segregation of the cellular microstructure that formed along the melt-pool boundaries for the solidification conditions that changed as a function of melt-pool dimensions.

  7. Single-Track Melt-Pool Measurements and Microstructures in Inconel 625

    Science.gov (United States)

    Ghosh, Supriyo; Ma, Li; Levine, Lyle E.; Ricker, Richard E.; Stoudt, Mark R.; Heigel, Jarred C.; Guyer, Jonathan E.

    2018-06-01

    We use single-track laser melting experiments and simulations on Inconel 625 to estimate the dimensions and microstructure of the resulting melt pool. Our work is based on a design-of-experiments approach which uses multiple laser power and scan speed combinations. Single-track experiments generated melt pools of certain dimensions that showed reasonable agreement with our finite-element calculations. Phase-field simulations were used to predict the size and segregation of the cellular microstructure that formed along the melt-pool boundaries for the solidification conditions that changed as a function of melt-pool dimensions.

  8. Designing remote connectedness between parents and their premature newly born : a design proposal

    NARCIS (Netherlands)

    Croes, M.J.G.; Bambang Oetomo, S.; Feijs, L.M.G.; Chen, W.; Bambang Oetomo, S.; Feijs, L.M.G.

    2012-01-01

    During a 6 month graduation project a design concept is proposed and developed that is expected to support the parent-child bonding while parents are at home and their child is in the NICU. In collaboration with medical practitioners from the Maxima Medical Centere Veldhoven (MMC) the new system for

  9. 3-dimensional thermohydraulic analysis of KALIMER reactor pool during unprotected accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Hahn Do Hee

    2003-01-01

    During a normal reactor scram, the heat generation is reduced almost instantaneously while the coolant flow rate follows the pump coastdown. This mismatch between power and flow results in a situation where the core flow entering the hot pool is at a lower temperature than the temperature of the bulk pool sodium. This temperature difference leads to thermal stratification. Thermal stratification can occur in the hot pool region if the entering coolant is colder than the existing hot pool coolant and the flow momentum is not large enough to overcome the negative buoyancy force. Since the fluid of hot pool enters IHXs, the temperature distribution of hot pool can alter the overall system response. Hence, it is necessary to predict the pool coolant temperature distribution with sufficient accuracy to determine the inlet temperature conditions for the IHXs and its contribution to the net buoyancy head. Therefore, two-dimensional hot pool thermohydraulic model named HP2D has been developed. In this report code-to-code comparison analysis between HP2D and COMMIX-1AR/P has been performed in the case of steady-state and UTOP.

  10. Volcanic glass signatures in spectroscopic survey of newly proposed lunar pyroclastic deposits

    Science.gov (United States)

    Besse, S.; Sunshine, J.M.; Gaddis, L.R.

    2014-01-01

    Moon Mineralogy Mapper spectroscopic observations are used to assess the mineralogy of five sites that have recently been proposed to include lunar dark mantle deposits (DMDs). Volcanic glasses have, for the first time, clearly been identified at the location of three of the proposed pyroclastic deposits. This is the first time that volcanic glasses have been identified at such a small scale on the lunar surface from remote sensing observations. Deposits at Birt E, Schluter, and Walther A appear to be glassy DMDs. Deposits at Birt E and Schluter show (1) morphological evidence suggesting a likely vent and (2) mineralogical evidence indicative of the presence of volcanic glasses. The Walther A deposits, although they show no morphological evidence of vents, have the spectroscopic characteristics diagnostic of volcanic glasses. The deposits of the Freundlich-Sharonov basin are separated in two areas: (1) the Buys-Ballot deposits lack mineralogical and morphological evidence and thus are found to be associated with mare volcanism not with DMDs and (2) the Anderson crater deposits, which do not exhibit glassy DMD signatures, but they appear to be associated with possible vent structures and so may be classifiable as DMDs. Finally, dark deposits near the crater Kopff are found to be associated with likely mare volcanism and not associated with DMDs. The spectral identification of volcanic glass seen in many of the potential DMDs is a strong indicator of their pyroclastic origin.

  11. Preliminary Calculation on a Spent Fuel Pool Accident using GOTHIC

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jaehwan; Choi, Yu Jung; Hong, Tae Hyub; Kim, Hyeong-Taek [KHNP-CRI, Daejeon (Korea, Republic of)

    2015-10-15

    The probability of an accident happening at the spent fuel pool was believed to be quite low until the 2011 Fukushima accident occurred. Notably, large amount of spent fuel are normally stored in the spent fuel pool for a long time compared to the amount of fuel in the reactor core and the total heat released from the spent fuel is high enough to boil the water of the spent fuel pool when the cooling system does not operate. In addition, the enrichment and the burnup of the fuel have both increased in the past decade and heat generation from the spent fuel thereby has also increased. The failure of the cooling system at the spent fuel pool (hereafter, a loss-of-cooling accident) is one of the principal hypothetical causes of an accident that could occur at the spent fuel pool. In this paper, the preliminary calculation of a loss-of-cooling accident was performed. In this paper, the preliminary calculation of a loss-of cooling accident was performed with GOTHIC. The calculation results show boiling away of water in the spent fuel pool due to the loss-of-cooling accident and similar thermal performance of the spent fuel pool with previous research results.

  12. Study on velocity distribution in a pool by submersible mixers

    International Nuclear Information System (INIS)

    Tian, F; Shi, W D; Lu, X N; Chen, B; Jiang, H

    2012-01-01

    To study the distribution of submersible mixers and agitating effect in the sewage treatment pool, Pro/E software was utilized to build the three-dimensional model. Then, the large-scale computational fluid dynamics software FLUENT6.3 was used. ICEM software was used to build unstructured grid of sewage treatment pool. After that, the sewage treatment pool was numerically simulated by dynamic coordinate system technology and RNG k-ε turbulent model and PIOS algorithm. The macro fluid field and each section velocity flow field distribution were analyzed to observe the efficiency of each submersible mixer. The average velocity and mixing area in the sewage pool were studied simultaneously. Results show that: the preferred project B, two submersible mixers speed is 980 r/min, and setting angles are all 30°. Fluid mixing area in the pool has reached more than 95%. Under the action of two mixers, the fluid in the sewage pool form a continuous circulating water flow. The fluid is mixed adequately and average velocity of fluid in the pool is at around 0.241m/s, which agreed with the work requirements. Consequently it can provide a reference basis for practical engineering application of submersible mixers by using this method.

  13. Pool Boiling CHF in Inclined Narrow Annuli

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2010-01-01

    Pool boiling heat transfer has been studied extensively since it is frequently encountered in various heat transfer equipment. Recently, it has been widely investigated in nuclear power plants for application to the advanced light water reactors designs. Through the review on the published results it can be concluded that knowledge on the combined effects of the surface orientation and a confined space on pool boiling heat transfer is of great practical importance and also of great academic interest. Fujita et al. investigated pool boiling heat transfer, from boiling inception to the critical heat flux (CHF, q' CHF ), in a confined narrow space between heated and unheated parallel rectangular plates. They identified that both the confined space and the surface orientation changed heat transfer much. Kim and Suh changed the surface orientation angles of a downward heating rectangular channel having a narrow gap from the downward-facing position (180 .deg.) to the vertical position (90 .deg.). They observed that the CHF generally decreased as the inclination angle (θ ) increased. Yao and Chang studied pool boiling heat transfer in a confined heat transfer for vertical narrow annuli with closed bottoms. They observed that when the gap size ( s ) of the annulus was decreased the effect of space confinement to boiling heat transfer increased. The CHF was occurred at much lower value for the confined space comparing to the unconfined pool boiling. Pool boiling heat transfer in narrow horizontal annular crevices was studied by Hung and Yao. They concluded that the CHF decreased with decreasing gap size of the annuli and described the importance of the thin film evaporation to explain the lower CHF of narrow crevices. The effect of the inclination angle on the CHF on countercurrent boiling in an inclined uniformly heated tube with closed bottoms was also studied by Liu et al. They concluded that the CHF reduced with the inclination angle decrease. A study was carried out

  14. Microbial diversity in acidic thermal pools in the Uzon Caldera, Kamchatka.

    Science.gov (United States)

    Mardanov, Andrey V; Gumerov, Vadim M; Beletsky, Alexey V; Ravin, Nikolai V

    2018-01-01

    Microbial communities of four acidic thermal pools in the Uzon Caldera, Kamchatka, Russia, were studied using amplification and pyrosequencing of 16S rRNA gene fragments. The sites differed in temperature and pH: 1805 (60 °C, pH 3.7), 1810 (90 °C, pH 4.1), 1818 (80 °C, pH 3.5), and 1807 (86 °C, pH 5.6). Archaea of the order Sulfolobales were present among the dominant groups in all four pools. Acidilobales dominated in pool 1818 but were a minor fraction at the higher temperature in pool 1810. Uncultivated Archaea of the Hot Thaumarchaeota-related clade were present in significant quantities in pools 1805 and 1807, but they were not abundant in pools 1810 and 1818, where high temperatures were combined with low pH. Nanoarchaeota were present in all pools, but were more abundant in pools 1810 and 1818. A similar abundance pattern was observed for Halobacteriales. Thermophilic Bacteria were less diverse and were mostly represented by aerobic hydrogen- and sulfur-oxidizers of the phylum Aquificae and sulfur-oxidising Proteobacteria of the genus Acidithiobacillus. Thus we showed that extremely acidic hot pools contain diverse microbial communities comprising different metabolic groups of prokaryotes, including putative lithoautotrophs using energy sources of volcanic origin, and various facultative and obligate heterotrophs.

  15. Effect of pool rotation on three-dimensional flow in a shallow annular pool of silicon melt with bidirectional temperature gradients

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Quan-Zhuang; Peng, Lan; Liu, Jia [Key Laboratory of Low-grade Energy Utilization Technologies and Systems of Ministry of Education, College of Power Engineering, Chongqing University, Chongqing, 400044 (China); Wang, Fei, E-mail: penglan@cqu.edu.cn [Chongqing Special Equipment Inspection and Research Institute, Chongqing, 401121 (China)

    2016-08-15

    In order to understand the effect of pool rotation on silicon melt flow with the bidirectional temperature gradients, we conducted a series of unsteady three-dimensional (3D) numerical simulations in a shallow annular pool. The bidirectional temperature gradients are produced by the temperature difference between outer and inner walls as well as a constant heat flux at the bottom. Results show that when Marangoni number is small, a 3D steady flow is common without pool rotation. But it bifurcates to a 3D oscillatory flow at a low rotation Reynolds number. Subsequently, the flow becomes steady and axisymmetric at a high rotation Reynolds number. When the Marangoni number is large, pool rotation can effectively suppress the temperature fluctuation on the free surface, meanwhile, it improves the flow stability. The critical heat flux density diagrams are mapped, and the effects of radial and vertical temperature gradients on the flow are discussed. Additionally, the transition process from the flow dominated by the radial temperature gradient to the one dominated by the vertical temperature gradient is presented. (paper)

  16. 13 CFR 120.1709 - Transfers of Pool Certificates.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Transfers of Pool Certificates. 120.1709 Section 120.1709 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1709...

  17. 13 CFR 120.1714 - Seller's Pool Loan servicing.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan servicing. 120.1714 Section 120.1714 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1714 Seller...

  18. 13 CFR 120.1715 - Seller's Pool Loan liquidation.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan liquidation. 120.1715 Section 120.1715 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1715 Seller...

  19. 13 CFR 120.1713 - Seller's Pool Loan origination.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan origination. 120.1713 Section 120.1713 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1713 Seller...

  20. 13 CFR 120.1717 - Seller's Pool Loan deferments.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's Pool Loan deferments. 120.1717 Section 120.1717 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1717 Seller...

  1. The pool chlorine hypothesis and asthma among boys.

    LENUS (Irish Health Repository)

    Cotter, A

    2012-01-31

    Swimming pool sanitation has largely been concerned with the microbiological quality of pool water, which is normally treated using a number of chlorine products. Recent studies have pointed to the potential hazards of chlorine by-products to the respiratory epithelium, particularly in indoor, poorly ventilated, pools. The aim of our study was to elucidate whether chronic exposure to indoor chlorinated swimming pools was associated with an increased likelihood of the development of asthma in boys. METHODS: The subjects were boys aged between 6 and 12 years. Data was collected by means of parental responses to a standardized asthma questionnaire (ISAAC: International Study of Asthma and Allergies in Childhood), supplemented with additional questions regarding frequency of attendance, number of years attendance, whether the child is a swimming team member. The questionnaire return rate was 71\\/% (n = 121). 23 boys were excluded on the basis that they had asthma before they started swimming (n = 97). There was a significant association between number of years a boy had been swimming and the likelihood of wheezing in the last 12 months (p = 0.009; OR = 1.351; 95% CI = 1.077-1.693) and diagnosed asthma (p = 0.046; OR = 1.299; 95% CI = 1.004-1.506). The greater the number the number of years a boy had been attending an indoor, chlorinated pool, the greater the likelihood of wheezing in the last 12 months or "had asthma". Age, parental smoking habits and being a swimming team member had no association with any of the asthma variables examined. Swimming pool attendance may be a risk factor in asthma in boys.

  2. Video quality pooling adaptive to perceptual distortion severity.

    Science.gov (United States)

    Park, Jincheol; Seshadrinathan, Kalpana; Lee, Sanghoon; Bovik, Alan Conrad

    2013-02-01

    It is generally recognized that severe video distortions that are transient in space and/or time have a large effect on overall perceived video quality. In order to understand this phenomena, we study the distribution of spatio-temporally local quality scores obtained from several video quality assessment (VQA) algorithms on videos suffering from compression and lossy transmission over communication channels. We propose a content adaptive spatial and temporal pooling strategy based on the observed distribution. Our method adaptively emphasizes "worst" scores along both the spatial and temporal dimensions of a video sequence and also considers the perceptual effect of large-area cohesive motion flow such as egomotion. We demonstrate the efficacy of the method by testing it using three different VQA algorithms on the LIVE Video Quality database and the EPFL-PoliMI video quality database.

  3. Seismic isolation structure for pool-type LMFBR - isolation building with vertically isolated floor for NSSS

    International Nuclear Information System (INIS)

    Sakurai, A.; Shiojiri, H.; Aoyagi, S.; Matsuda, T.; Fujimoto, S.; Sasaki, Y.; Hirayama, H.

    1987-01-01

    The NSSS isolation floor vibration characteristics were made clear. Especially, the side support bearing (rubber bearing) is effective for horizontal floor motion restraint and rocking motion control. Seismic isolation effects for responses of the reactor components can be sufficiently expected, using the vertical seismic isolation floor. From the analytical and experimental studies, the following has been concluded: (1) Seismic isolation structure, which is suitable for large pool-type LMFBR, were proposed. (2) Seismic response characteristics of the seismic isolation structure were investigated. It was made clear that the proposed seismic isolation (Combination of the isolated building and the isolated NSSS floor) was effective. (orig./HP)

  4. Evaporation rate measurement in the pool of IEAR-1 reactor

    International Nuclear Information System (INIS)

    Torres, Walmir Maximo; Cegalla, Miriam A.; Baptista Filho, Benedito Dias

    2000-01-01

    The surface water evaporation in pool type reactors affects the ventilation system operation and the ambient conditions and dose rates in the operation room. This paper shows the results of evaporation rate experiment in the pool of IEA-R1 research reactor. The experiment is based on the demineralized water mass variation inside cylindrical metallic recipients during a time interval. Other parameters were measured, such as: barometric pressure, relative humidity, environmental temperature, water temperature inside the recipients and water temperature in the reactor pool. The pool level variation due to water contraction/expansion was calculated. (author)

  5. Evaluation of alternatives for power system coordination and pooling in a competitive environment

    International Nuclear Information System (INIS)

    Rudnick, H.; Varela, R.; Hogan, W.

    1997-01-01

    The paper defines and classifies essential issues that relate the need for electric power system coordination with the increasing development of competition. Principles are formulated and a coordination model and a market structure are proposed, emphasizing the need for economic dispatch in the wholesale market. A detailed comparison is made of the market and pooling implementations developed in Argentina and Chile, countries that have pioneered the creation of competitive markets in the electric energy sector. An evaluation of strengths and weaknesses of those two implementations is included

  6. Phase analysis in gated blood pool tomography

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Tada, Akira; Taki, Junichi; Nanbu, Ichiro

    1984-01-01

    Phase analysis of gated blood pool study has been applied to detect the site of accessory conduction pathway (ACP) in the Wolff-Parkinson-White (WPW) syndrome; however, there was a limitation to detect the precise location of ACP by phase analysis alone. In this study, we applied phase analysis to gated blood pool tomography using seven pin hole tomography (7PT) and gated emission computed tomography (GECT) in 21 patients with WPW syndrome and 3 normal subjects. In 17 patients, the sites of ACPs were confirmed by epicardial mapping and the result of the surgical division of ACP. In 7PT, the site of ACP grossly agreed to the abnormal initial phase in phase image in 5 out of 6 patients with left cardiac type. In GECT, phase images were generated in short axial, vertical and horizontal long axial sections. In 8 out of 9 patients, the site of ACP was correctly identified by phase images, and in a patient who had two ACPs, initial phase corresponded to one of the two locations. Phase analysis of gated blood pool tomography has advantages for avoiding overlap of blood pools and for estimating three-dimensional propagation of the contraction, and can be a good adjunctive method in patients with WPW syndrome. (author)

  7. Reflection of illumination laser from gas metal arc weld pool surface

    International Nuclear Information System (INIS)

    Ma, Xiaoji; Zhang, YuMing

    2009-01-01

    The weld pool is the core of the welding process where complex welding phenomena originate. Skilled welders acquire their process feedback primarily from the weld pool. Observation and measurement of the three-dimensional weld pool surface thus play a fundamental role in understanding and future control of complex welding processes. To this end, a laser line is projected onto the weld pool surface in pulsed gas metal arc welding (GMAW) and an imaging plane is used to intercept its reflection from the weld pool surface. Resultant images of the reflected laser are analyzed and it is found that the weld pool surface in GMAW does specularly reflect the projected laser as in gas tungsten arc welding (GTAW). Hence, the weld pool surface in GMAW is also specular and it is in principle possible that it may be observed and measured by projecting a laser pattern and then intercepting and imaging the reflection from it. Due to high frequencies of surface fluctuations, GMAW requires a relatively short time to image the reflected laser

  8. SBWR PCCS vent phenomena and suppression pool mixing

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, P. [Thermal-Hydraulics Lab., Paul Scherrer Institute, Villigen (Switzerland); Andreani, M. [Nuclear Engineering Lab., Swiss Federal Institute of Technology, Zurich (Switzerland)

    1995-09-01

    The most important phenomena influencing the effectiveness of the pressure suppression capability of the water pool within the Wetwell compartment of the SBWR Containment, during the period of Passive Containment Cooling System (PCCS) venting, have been critically reviewed. In addition, calculations have been carried-out to determine the condensation of the vented steam and the distribution of the energy deposited in the liquid pool. It has been found that a large contribution to the vapour suppression is due to condensation inside the vent pipe. The condensation rate of the steam inside the bubbles, produced at the vent exit, during their rise to the surface, may however be rather low, because of the large size bubbles. This can lead to vapour channelling to the Wetwell gas space. The above comments are likely to be ameliorated if the vent exit is a distributed source or sparger. Due to the large water flow rates within the {open_quotes}bubbly two-phase plume{close_quotes} generated by the gas injection, the water in the pool above the vent exit is likely to be heated nearly isothermally (perfect mixing). The effect of the suppression pool walls would be to enhance the recirculation and, consequently to promote mixing. The large size of the bubbles therein and of the walls on pool mixing are the most severe difficulties in extrapolating the results from scaled experiments to prototypical conditions.

  9. The management of the Spend Fuel Pool Water Quality (1996-2007)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Lee, Eui Gyu; Choi, Ho Young; Choi, Mun Jo; Kim, Hyung Wook; Lee, Mun; Lee, Choong Sung; Hur, Soon Ock; Ahn, Guk Hun

    2008-12-15

    The water quality management of spent fuel storage pool water quality in HANARO is important to prevent the corrosion of nuclear fuel and reactor structure material. The condition of the spent fuel storage pool water has been monitored by measuring the electrical conductivity of the spent fuel storage pool purification system and pH periodically. The status of the spent fuel storage pool water quality management was investigated by using the measured data. taken from 1996 to 2007. In general, the electrical conductivity of the spent fuel storage pool water have been managed within 1 {mu}S/cm which is an operation target of HANARO.

  10. Predicting the emissive power of hydrocarbon pool fires

    International Nuclear Information System (INIS)

    Munoz, Miguel; Planas, Eulalia; Ferrero, Fabio; Casal, Joaquim

    2007-01-01

    The emissive power (E) of a flame depends on the size of the fire and the type of fuel. In fact, it changes significantly over the flame surface: the zones of luminous flame have high emittance, while those covered by smoke have low E values. The emissive power of each zone (that is, the luminous or clear flame and the non-luminous or smoky flame) and the portion of total flame area they occupy must be assessed when a two-zone model is used. In this study, data obtained from an experimental set-up were used to estimate the emissive power of fires and its behaviour as a function of pool size. The experiments were performed using gasoline and diesel oil as fuel. Five concentric circular pools (1.5, 3, 4, 5 and 6 m in diameter) were used. Appropriate instruments were employed to determine the main features of the fires. By superimposing IR and VHS images it was possible to accurately identify the luminous and non-luminous zones of the fire. Mathematical expressions were obtained that give a more accurate prediction of E lum , E soot and the average emissive power of a fire as a function of its luminous and smoky zones. These expressions can be used in a two-zone model to obtain a better prediction of the thermal radiation. The value of the radiative fraction was determined from the thermal flux measured with radiometers. An expression is also proposed for estimating the radiative fraction

  11. Biomass and carbon pools of disturbed riparian forests

    Science.gov (United States)

    Laura A. B. Giese; W. M. Aust; Randall K. Kolka; Carl C. Trettin

    2003-01-01

    Quantification of carbon pools as affected by forest age/development can facilitate riparian restoration and increase awareness of the potential for forests to sequester global carbon. Riparian forest biomass and carbon pools were quantified for four riparian forests representing different seral stages in the South Carolina Upper Coastal Plain. Three of the riparian...

  12. Solar collectors for swimming pools still going strong

    Energy Technology Data Exchange (ETDEWEB)

    1975-01-01

    According to the opinion of the experts, solar energy heating may be technically 'mature' but the profitability is by no means that far. However, solar systems are a good alternative for heating the water in swimming pools. Four solar collector systems developed by different firms to heat swimming pools, including prices, are presented.

  13. Mycobacterium arupense, Mycobacterium heraklionense, and a Newly Proposed Species, “Mycobacterium virginiense” sp. nov., but Not Mycobacterium nonchromogenicum, as Species of the Mycobacterium terrae Complex Causing Tenosynovitis and Osteomyelitis

    Science.gov (United States)

    Vasireddy, Sruthi; Brown-Elliott, Barbara A.; Wengenack, Nancy L.; Eke, Uzoamaka A.; Benwill, Jeana L.; Turenne, Christine; Wallace, Richard J.

    2016-01-01

    Mycobacterium terrae complex has been recognized as a cause of tenosynovitis, with M. terrae and Mycobacterium nonchromogenicum reported as the primary etiologic pathogens. The molecular taxonomy of the M. terrae complex causing tenosynovitis has not been established despite approximately 50 previously reported cases. We evaluated 26 isolates of the M. terrae complex associated with tenosynovitis or osteomyelitis recovered between 1984 and 2014 from 13 states, including 5 isolates reported in 1991 as M. nonchromogenicum by nonmolecular methods. The isolates belonged to three validated species, one new proposed species, and two novel related strains. The majority of isolates (20/26, or 77%) belonged to two recently described species: Mycobacterium arupense (10 isolates, or 38%) and Mycobacterium heraklionense (10 isolates, or 38%). Three isolates (12%) had 100% sequence identity to each other by 16S rRNA and 99.3 to 100% identity by rpoB gene region V sequencing and represent a previously undescribed species within the M. terrae complex. There were no isolates of M. terrae or M. nonchromogenicum, including among the five isolates reported in 1991. The 26 isolates were susceptible to clarithromycin (100%), rifabutin (100%), ethambutol (92%), and sulfamethoxazole or trimethoprim-sulfamethoxazole (70%). The current study suggests that M. arupense, M. heraklionense, and a newly proposed species (“M. virginiense” sp. nov.; proposed type strain MO-233 [DSM 100883, CIP 110918]) within the M. terrae complex are the major causes of tenosynovitis and osteomyelitis in the United States, with little change over 20 years. Species identification within this complex requires sequencing methods. PMID:26962085

  14. Cytoplasmic assembly of snRNP particles from stored proteins and newly transcribed snRNA's in L929 mouse fibroblasts

    International Nuclear Information System (INIS)

    Sauterer, R.A.; Feeney, R.J.; Zieve, G.W.

    1988-01-01

    Newly synthesized snRNAs appear transiently in the cytoplasm where they assemble into ribonucleoprotein particles, the snRNP particles, before returning permanently to the interphase nucleus. In this report, bona fide cytoplasmic fractions, prepared by cell enucleation, are used for a quantitative analysis of snRNP assembly in growing mouse fibroblasts. The half-lives and abundances of the snRNP precursors in the cytoplasm and the rates of snRNP assembly are calculated in L929 cells. With the exception of U6, the major snRNAs are stable RNA species; U1 is almost totally stable while U2 has a half-life of about two cell cycles. In contrast, the majority of newly synthesized U6 decays with a half-life of about 15 h. The relative abundances of the newly synthesized snRNA species U1, U2, U3, U4 and U6 in the cytoplasm are determined by Northern hybridization using cloned probes and are approximately 2% of their nuclear abundance. The half-lives of the two major snRNA precursors in the cytoplasm (U1 and U2) are approximately 20 min as determined by labeling to steady state. The relative abundance of the snRNP B protein in the cytoplasm is determined by Western blotting with the Sm class of autoantibodies and is approximately 25% of the nuclear abundance. Kinetic studies, using the Sm antiserum to immunoprecipitate the methionine-labeled snRNP proteins, suggest that the B protein has a half-life of 90 to 120 min in the cytoplasm. These data are discussed and suggest that there is a large pool of more stable snRNP proteins in the cytoplasm available for assembly with the less abundant but more rapidly turning-over snRNAs

  15. Lip and tooth injuries at public swimming pools in Austria.

    Science.gov (United States)

    Lechner, Katharina; Connert, Thomas; Kühl, Sebastian; Filippi, Andreas

    2017-06-01

    There is an increased risk of orofacial injuries in swimming pool facilities. Nevertheless, only a few studies have addressed this issue. The aim of this study was to identify the frequency of lip and tooth injuries at public swimming pools in Austria. A further aim was to examine which gender and age groups were affected, where and why these injuries occurred, and whether pool attendants had sufficient knowledge of dental first-aid measures. A total of 764 pool attendants in Austria were contacted by telephone and 689 participated in the study (90.2%). The attendants were interviewed retrospectively about accident occurrences in 2014 by a standardized questionnaire. Responses to the provision of first aid and choice of storage medium for avulsed teeth were subsequently evaluated. The frequency of lip injuries was 19.0%, and tooth injuries were 11.3%. Male bathers (P < .05) and children under 12 years (P < .001) most frequently suffered injuries. The waterslide was the most common accident site. The most common cause of lip injuries was slipping on wet surfaces (39.0%), and for tooth injuries it was collisions with other persons or objects (each 28.1%). The pool attendants' responses were predominantly good or sufficient on first aid, with the exception of what storage medium to choose. Tooth rescue boxes were available in only 8.6% of all pool facilities. Orofacial injuries are a frequently occurring problem in swimming pool facilities. The pool attendants' knowledge on first-aid care of tooth injuries could still be improved. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Branchipodopsis species — specialists of ephemeral rock pools ...

    African Journals Online (AJOL)

    Such rock pools were studied in the Drakensberg region, in the eastern Free State and in south-eastern Botswana. Common features ... While short-range dispersal of floating eggs by overflows is common, long-range dispersal (e.g. by wind) seems to be rare and to be restricted to shallow pools with little vegetation. Limited ...

  17. CO{sub 2} flooding performance prediction for Alberta oil pools

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, J.C. [Adams Pearson Associates Inc., Calgary, AB (Canada); Bachu, S. [Alberta Energy and Utilities Board, Calgary, AB (Canada)

    2002-06-01

    An advanced technical screening program was used to successfully screen and rank a very large number of Alberta oil pools for enhanced oil recovery using carbon dioxide (CO{sub 2}) flooding. This paper is a continuation paper describing the results of using the Microsoft Excel program with VBA to estimate production forecasts for several candidate pools in Alberta. A total of 6 ranking parameters were used, including API gravity of oil, residual oil saturation, ratio between reservoir pressure and minimum miscibility pressure, reservoir temperature, net pay thickness and porosity. The screening program provides a technical ranking of approximately 8,000 Alberta pools. After compilation of the Alberta oil pools, it was determined that most of the deep carbonate oil pools are excellent candidates for CO{sub 2} miscible flooding. Other Devonian carbonate pools are also ranked as having high potential for the process. An environmental benefit of CO{sub 2} miscible flooding process is that carbon sequestration has the potential to reduce anthropogenic carbon dioxide emissions from reaching the atmosphere. Ongoing studies are currently addressing CO{sub 2} capture and transportation, making EOR technology viable for maintaining light oil production in western Canada. 11 refs., 2 tabs., 2 figs.

  18. AE/VCE Unconfirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  19. AE/VCE Confirmed Vernal Pools

    Data.gov (United States)

    Vermont Center for Geographic Information — This dataset is derived from a project by the Vermont Center for Ecostudies(VCE) and Arrowwood Environmental(AE) to map vernal pools throughout the state of Vermont....

  20. Energy Pooling Upconversion in Free Space and Optical Cavities

    Science.gov (United States)

    LaCount, Michael D.

    The ability to efficiently convert the wavelength of light has value in a wide range of disciplines that include the fields of photovoltaics, plant growth, optics and medicine. The processes by which such transformations are carried out are known as upconversions and downconversions. There are several ways to up/down convert light, each with its own attributes, issues, and competing mechanisms. Most are associated with one-body or two-body processes. Three-body dynamics are also possible though, going by the names of quantum cutting (downconversion) and energy pooling (upconversion). These use virtual excited electronic states to mediate conversions as has been experimentally realized using lanthanide ions embedded in wide bandgap materials. The use of lanthanides to convert light is not ideal due to their relative scarcity, toxicity, and the limited range of light frequencies that can be absorbed and emitted. Organic molecules, on the other hand, are typically non-toxic, are made up of abundant elements, and can be designed with tailored spectral properties. At issue is whether or not they can be used to carry out efficient energy pooling, the central question to be answered in this thesis. The research presented here draws on a perturbative quantum electrodynamics framework previously established for generic energy pooling. It was used to develop a computational methodology for determining the rate of energy pooling and its competing processes. This, in turn, draws on a combination of time-dependent density functional theory, quantum electrodynamics, and perturbation theory to generate the requisite material property data. This computational model was applied to two test systems consisting of stilbene-fluorescein and hexabenzocoronene-oligothiophene. The stilbene-fluorescein system was found to have a maximum energy pooling rate efficiency (as compared to competing processes) of 17% and the hexabenzocoronene-oligothiophene system was found to have a maximum

  1. Inferring local ecological processes amid species pool influences

    DEFF Research Database (Denmark)

    Lessard, Jean-Philippe; Belmaker, Jonathan; Myers, Jonathan A.

    2012-01-01

    studies, null models of community structure, and ecologically explicit definitions of the species pool as a means to compare predominant ecological processes among regions. By uniting concepts and tools from community ecology and macroecology, this approach might facilitate synthesis and resolve many......Resolving contingencies in community ecology requires comparative studies of local communities along broad-scale environmental gradients and in different biogeographic regions. However, comparisons of local ecological processes among regions require a synthetic understanding of how the species pool...... of potential community members influences the structure of ecological communities. Here, we outline an integrative approach for quantifying local ecological processes while explicitly accounting for species pool influences. Specifically, we highlight the utility of combining geographically replicated local...

  2. Alcoholism Detection by Data Augmentation and Convolutional Neural Network with Stochastic Pooling.

    Science.gov (United States)

    Wang, Shui-Hua; Lv, Yi-Ding; Sui, Yuxiu; Liu, Shuai; Wang, Su-Jing; Zhang, Yu-Dong

    2017-11-17

    Alcohol use disorder (AUD) is an important brain disease. It alters the brain structure. Recently, scholars tend to use computer vision based techniques to detect AUD. We collected 235 subjects, 114 alcoholic and 121 non-alcoholic. Among the 235 image, 100 images were used as training set, and data augmentation method was used. The rest 135 images were used as test set. Further, we chose the latest powerful technique-convolutional neural network (CNN) based on convolutional layer, rectified linear unit layer, pooling layer, fully connected layer, and softmax layer. We also compared three different pooling techniques: max pooling, average pooling, and stochastic pooling. The results showed that our method achieved a sensitivity of 96.88%, a specificity of 97.18%, and an accuracy of 97.04%. Our method was better than three state-of-the-art approaches. Besides, stochastic pooling performed better than other max pooling and average pooling. We validated CNN with five convolution layers and two fully connected layers performed the best. The GPU yielded a 149× acceleration in training and a 166× acceleration in test, compared to CPU.

  3. Is energy pooling necessary in ultraviolet matrix-assisted laser desorption/ionization?

    Science.gov (United States)

    Lin, Hou-Yu; Song, Botao; Lu, I-Chung; Hsu, Kuo-Tung; Liao, Chih-Yu; Lee, Yin-Yu; Tseng, Chien-Ming; Lee, Yuan-Tseh; Ni, Chi-Kung

    2014-01-15

    Energy pooling has been suggested as the key process for generating the primary ions during ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI). In previous studies, decreases in fluorescence quantum yields as laser fluence increased for 2-aminobenzoic acid, 2,5-dihydroxybenzoic acid (2,5-DHB), and 3-hydroxypicolinic acid were used as evidence of energy pooling. This work extends the research to other matrices and addresses whether energy pooling is a universal property in UV-MALDI. Energy pooling was investigated in a time-resolved fluorescence experiment by using a short laser pulse (355 nm, 20 ps pulse width) for excitation and a streak camera (1 ps time resolution) for fluorescence detection. The excited-state lifetime of 2,5-DHB decreased with increases in laser fluence. This suggests that a reaction occurs between two excited molecules, and that energy pooling may be one of the possible reactions. However, the excited-state lifetime of 2,4,6-trihydroxyacetophenone (THAP) did not change with increases in laser fluence. The upper limit of the energy pooling rate constant for THAP is estimated to be approximately 100-500 times smaller than that of 2,5-DHB. The small energy pooling rate constant for THAP indicates that the potential contribution of the energy pooling mechanism to the generation of THAP matrix primary ions should be reconsidered. Copyright © 2013 John Wiley & Sons, Ltd.

  4. ENERGY STAR Certified Pool Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.1 ENERGY STAR Program Requirements for Pool Pumps that are effective as of February 15,...

  5. Conception of a sub aquatic lighting system for nuclear fuels storage pools

    International Nuclear Information System (INIS)

    Bracco, P.; Rosenthal, E.

    1990-01-01

    Restrictions like contaminated water, irradiated fuel elements in racks located on the bottom of the pool and the impossibility of removing the water, require a non conventional design of pool lamps. The model developed is independent of the pool, permitting easily fabrication and maintenance. They are made of stainless steel tubes with borosilicate windows, where floodlight or light are located. The lamp assembly is fixed at the border of the pool. The system offers advantages over the conventional pool lighting systems in fabrication, operation and maintenance. (author)

  6. Strategies for chemically healthy public swimming pools

    DEFF Research Database (Denmark)

    Hansen, Kamilla Marie Speht

    spreading of pathogens between swimmers because of its residual disinfection effect. In addition to potential contamination of pathogenic microorganisms, swimming pool water is polluted by organic matter deposited from the bathers such as saliva, urine, sweat, hair and personal care products. Since chlorine...... is a strong oxidant it oxidizes the organic matter in the pool water and forms disinfection byproducts (DBPs). More than 100 different DBPs have been identified. Some of these have been found to be genotoxic and may pose an increased cancer risk for the bathers. The aim of this thesis was to give an overview...... of the strategies which can be used to achieve microbiological safe water with low levels of DBPs to ensure healthy environment for bathers. There are different approaches to achieve healthy environment in public swimming pools which in this thesis are divided into three strategies: alternatives to chlorination...

  7. Citizen science and natural resource governance: program design for vernal pool policy innovation

    Directory of Open Access Journals (Sweden)

    Bridie McGreavy

    2016-06-01

    Full Text Available Effective natural resource policy depends on knowing what is needed to sustain a resource and building the capacity to identify, develop, and implement flexible policies. This retrospective case study applies resilience concepts to a 16-year citizen science program and vernal pool regulatory development process in Maine, USA. We describe how citizen science improved adaptive capacities for innovative and effective policies to regulate vernal pools. We identified two core program elements that allowed people to act within narrow windows of opportunity for policy transformation, including (1 the simultaneous generation of useful, credible scientific knowledge and construction of networks among diverse institutions, and (2 the formation of diverse leadership that promoted individual and collective abilities to identify problems and propose policy solutions. If citizen science program leaders want to promote social-ecological systems resilience and natural resource policies as outcomes, we recommend they create a system for internal project evaluation, publish scientific studies using citizen science data, pursue resources for program sustainability, and plan for leadership diversity and informal networks to foster adaptive governance.

  8. Corium quench in deep pool mixing experiments

    International Nuclear Information System (INIS)

    Spencer, B.W.; McUmber, L.; Gregorash, D.; Aeschlimann, R.; Sienicki, J.J.

    1985-01-01

    The results of two recent corium-water thermal interaction (CWTI) tests are described in which a stream of molten corium was poured into a deep pool of water in order to determine the mixing behavior, the corium-to-water heat transfer rates, and the characteristic sizes of the quenched debris. The corium composition was 60% UO 2 , 16% ZrO 2 , and 24% stainless steel by weight; its initial temperature was 3080 K, approx.160 K above the oxide phase liquidus temperature. The corium pour stream was a single-phase 2.2 cm dia liquid column which entered the water pool in film boiling at approx.4 m/s. The water subcooling was 6 and 75C in the two tests. Test results showed that with low subcooling, rapid steam generation caused the pool to boil up into a high void fraction regime. In contrast, with large subcooling no net steam generation occurred, and the pool remained relatively quiescent. Breakup of the jet appeared to occur by surface stripping. In neither test was the breakup complete during transit through the 32 cm deep water pool, and molten corium channeled to the base where it formed a melt layer. The characteristic heat transfer rates measured 3.5 MJ/s and 2.7 MJ/s during the fall stage for small and large subcooling, respectively; during the initial stage of bed quench, the surface heat fluxes measured 2.4 MW/m 2 and 3.7 MW/m 2 , respectively. A small mass of particles was formed in each test, measuring typically 0.1 to 1 mm and 1 to 5 mm dia for the large and small subcooling conditions, respectively. 9 refs., 13 figs., 1 tab

  9. Assessing urban logistics pooling sustainability via a hierarchic dashboard from a group decision perspective

    OpenAIRE

    Gonzalez-Feliu, Jesus; Morana, Joëlle

    2014-01-01

    This paper aims to propose, via an experimental collaborative decision support method, to define a grid of indicators and a reference situation database to measure the sustainable performance of urban logistics pooling systems. To do this, we start by defining the notion of sustainability in the 4As approach, after what we identify the main sustainability indicators from an overview of the literature, and class them into four categories (one for each A of the approach). Then, a group of 20 ex...

  10. Association studies using family pools of outcrossing crops based on allele-frequency estimates from DNA sequencing

    DEFF Research Database (Denmark)

    Ashraf, Bilal; Jensen, Just; Asp, Torben

    2014-01-01

    effect from F2-family pools was verified and it was shown that the underestimation of the allele effect is correctly described. The optimal design for an association study when sequencing budget would be fixed is obtained using large sample size and lower sequence depth, and using higher SNP density......F2 families are frequently used in breeding of outcrossing species, for instance to obtain trait measurements on plots. We propose to perform association studies by obtaining a matching “family genotype” from sequencing a pooled sample of the family, and to directly use allele frequencies computed...... (resulting in higher LD with causative mutations) and lower sequencing depth. Therefore, association studies using genotyping by sequencing are optimal and use low sequencing depth per sample. The developed framework for association studies using allele frequencies from sequencing can be modified for other...

  11. Confidence in leadership among the newly qualified.

    Science.gov (United States)

    Bayliss-Pratt, Lisa; Morley, Mary; Bagley, Liz; Alderson, Steven

    2013-10-23

    The Francis report highlighted the importance of strong leadership from health professionals but it is unclear how prepared those who are newly qualified feel to take on a leadership role. We aimed to assess the confidence of newly qualified health professionals working in the West Midlands in the different competencies of the NHS Leadership Framework. Most respondents felt confident in their abilities to demonstrate personal qualities and work with others, but less so at managing or improving services or setting direction.

  12. Assessment of a volume-dependent dynamic respiratory system compliance in ALI/ARDS by pooling breathing cycles

    International Nuclear Information System (INIS)

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    New methods were developed to calculate the volume-dependent dynamic respiratory system compliance (C rs ) in mechanically ventilated patients. Due to noise in respiratory signals and different characteristics of the methods, their results can considerably differ. The aim of the study was to establish a practical procedure to validate the estimation of intratidal dynamic C rs . A total of 28 patients from intensive care units of eight German university hospitals with acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) were studied retrospectively. Dynamic volume-dependent C rs was determined during ongoing mechanical ventilation with the SLICE method, dynostatic algorithm and adaptive slice method. Conventional two-point compliance C 2P was calculated for comparison. A number of consecutive breathing cycles were pooled to reduce noise in the respiratory signals. C rs -volume curves produced with different methods converged when the number of pooling cycles increased (n ≥ 7). The mean volume-dependent C rs of 20 breaths was highly correlated with mean C 2P (C 2P,mean = 0.945 × C rs,mean − 0.053, r 2 = 0.968, p < 0.0001). The Bland–Altman analysis indicated that C 2P,mean was lower than C rs,mean (−2.4 ± 6.4 ml cm −1 H 2 O, mean bias ± 2 SD), but not significant according to the paired t-test (p > 0.05). Methods for analyzing dynamic respiratory mechanics are sensitive to noise and will converge to a unique solution when the number of pooled cycles increases. Under steady-state conditions, assessment of the volume-dependent C rs in ALI/ARDS patients can be validated by pooling respiratory data of consecutive breaths regardless of which method is applied. Confidence in dynamic C rs determination may be increased with the proposed pooling. (note)

  13. Liquid sodium pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Casselman, C [DSN/SESTR, Centre de Cadarache, Saint-Paul-lez-Durance (France)

    1979-03-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  14. Liquid sodium pool fires

    International Nuclear Information System (INIS)

    Casselman, C.

    1979-01-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  15. Hydrodynamics and heat transfer characteristics of liquid pools with bubble agitation

    International Nuclear Information System (INIS)

    Blottner, F.G.

    1979-11-01

    Estimates are given for the heat transfer coefficients at various interfaces which occur in molten pools on concrete. Previous simulant experiments and correlations are used to determine the hydrodynamic behavior of the pool and heat transfer coefficients for the liquids of interest. Other studies assume a gas film occurs between the concrete and molten pool, but the results of this investigation do not confirm this assumption. The results also indicate the significant influence the very viscous concrete slag has on the properties of the molten pool. Additional experiments and analysis are needed to improve the accuracy of the heat transfer coefficients estimated and to understand the behavior of the concrete slag at the interface between the pool and decomposing concrete

  16. SAR target recognition and posture estimation using spatial pyramid pooling within CNN

    Science.gov (United States)

    Peng, Lijiang; Liu, Xiaohua; Liu, Ming; Dong, Liquan; Hui, Mei; Zhao, Yuejin

    2018-01-01

    Many convolution neural networks(CNN) architectures have been proposed to strengthen the performance on synthetic aperture radar automatic target recognition (SAR-ATR) and obtained state-of-art results on targets classification on MSTAR database, but few methods concern about the estimation of depression angle and azimuth angle of targets. To get better effect on learning representation of hierarchies of features on both 10-class target classification task and target posture estimation tasks, we propose a new CNN architecture with spatial pyramid pooling(SPP) which can build high hierarchy of features map by dividing the convolved feature maps from finer to coarser levels to aggregate local features of SAR images. Experimental results on MSTAR database show that the proposed architecture can get high recognition accuracy as 99.57% on 10-class target classification task as the most current state-of-art methods, and also get excellent performance on target posture estimation tasks which pays attention to depression angle variety and azimuth angle variety. What's more, the results inspire us the application of deep learning on SAR target posture description.

  17. Investigation to radioactive contamination of pool water in IMEF

    International Nuclear Information System (INIS)

    Song, Ung Sup; Jung, Yang Hong; Lee, J. H.; Lee, H. K.

    2003-06-01

    The pool (3x6x10) in irradiated materials examination facility is usually used for the purpose of taking the specimen out of cask loaded into the pool, and carrying in/out the specimen to/ from the hot cell. Always, it must be cared for the water into the pool to be fine condition because all operation are worked with the naked eye during taking an irradiated materials out of the cask and plunging them in the bucket-elevator. In the aspects of the radioactive remained substances in the water must be controlled so that the amount of substances to be lower than the standard amount prescribed by RCA Korea Activity in a part of radioactive contamination control. In consequence, an expertness of status and a practical use of skill make possible the prevention of radioactive material's diffusion or the radioactive contamination of pool water and safety work

  18. CAREM 25: Suppression pool cooling and purification system

    International Nuclear Information System (INIS)

    Carlevaris, Rodolfo; Patrignani, Alberto; Vindrola, Carlos; Palmerio, Hector D.; Quiroz, Horacio; Ramilo, Lucia B.

    2000-01-01

    The suppression pool cooling and purification system has the following main functions: purify and cool water from the suppression pool, cool and send water to the residual heat extraction system, and transfer water to the fuel element transference channel. In case of Loss of Coolant Accident (LOCA), the system sends water from the suppression pool to the spray network, thus cooling and reducing pressure in the primary containment. The system has been designed in accordance with the requirements of the following standards: ANSI/ANS 52.1; ANSI/ANS 57.2; ANSI/ANS 56.2; ANSI/ANS 59.1; ANSI/ANS 58.3; ANSI/ANS 58.9; and ANSI/ANS 56.5. The design of the system fulfils all the assigned functions. (author)

  19. Topography Battles Surface Texture: An Experimental Study of Pool-riffle Formation

    Science.gov (United States)

    Chartrand, S. M.; Hassan, M. A.; Jellinek, M.

    2016-12-01

    Pool-riffles are perhaps the most common streambed shape found in streams and rivers, and not surprisingly, they are essential to salmon ecology, and are a central focus of many restoration actions. Yet, when an applied earth scientist or engineer is faced with developing a pool-riffle design, there is a lack of clear and rigorously developed design guidelines. Given the volumes of money spent annually within the restoration industry, this is a real problem. Recognition of this problem is growing, however, and an increasing level of attention has been directed to questions of pool-riffle formation in the past decade. At this point and given certain landscape characteristics, it is well established that streamwise gradients in channel width are associated with pool-riffles. Specifically, pools are associated with negative gradients in width, and riffles with positive gradients. Importantly, these associations have now been documented from field-derived data, as well as via experimental and numerical investigations. There is much to build from the present knowledge base, and central to this are questions related to (a) how pool-riffles evolve during the formative process, (b) what are the basic set of ingredients necessary for pool-riffle formation within systems characterized by relatively non-erodible channel margins, and (c) do pool-riffles persist, once formed, under a broad range of forcing conditions? We have completed four physical experiments examining the process and evolution of pool-riffle formation under a large range of upstream boundary, as well as physical channel conditions. We will report on two of the completed experiments. Our work will highlight two new non-dimensional channel evolution numbers, derived to help describe and characterize bedform development, as well as response to perturbations from near-equilibrium conditions. The channel evolution numbers lay the foundation for development of a new regime diagram, which quantifies the basic

  20. Laboratory investigation and simulation of breakthrough curves in karst conduits with pools

    Science.gov (United States)

    Zhao, Xiaoer; Chang, Yong; Wu, Jichun; Peng, Fu

    2017-12-01

    A series of laboratory experiments are performed under various hydrological conditions to analyze the effect of pools in pipes on breakthrough curves (BTCs). The BTCs are generated after instantaneous injections of NaCl tracer solution. In order to test the feasibility of reproducing the BTCs and obtain transport parameters, three modeling approaches have been applied: the equilibrium model, the linear graphical method and the two-region nonequilibrium model. The investigation results show that pools induce tailing of the BTCs, and the shapes of BTCs depend on pool geometries and hydrological conditions. The simulations reveal that the two-region nonequilibrium model yields the best fits to experimental BTCs because the model can describe the transient storage in pools by the partition coefficient and the mass transfer coefficient. The model parameters indicate that pools produce high dispersion. The increased tailing occurs mainly because the partition coefficient decreases, as the number of pools increases. When comparing the tracer BTCs obtained using the two types of pools with the same size, the more appreciable BTC tails that occur for symmetrical pools likely result mainly from the less intense exchange between the water in the pools and the water in the pipe, because the partition coefficients for the two types of pools are virtually identical. Dispersivity values decrease as flow rates increase; however, the trend in dispersion is not clear. The reduced tailing is attributed to a decrease in immobile water with increasing flow rate. It provides evidence for hydrodynamically controlled tailing effects.

  1. 17 CFR 275.206(4)-8 - Pooled investment vehicles.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Pooled investment vehicles... COMMISSION (CONTINUED) RULES AND REGULATIONS, INVESTMENT ADVISERS ACT OF 1940 § 275.206(4)-8 Pooled investment vehicles. (a) Prohibition. It shall constitute a fraudulent, deceptive, or manipulative act...

  2. The construction of social identity in newly recruited nuclear engineering staff: A longitudinal study

    International Nuclear Information System (INIS)

    Nguyen, Lynda; Murphy, Glen; Chang, Artemis

    2014-01-01

    This study examines the process by which newly recruited nuclear engineering and technical staff came to understand, define, think, feel and behave within a distinct group that has a direct contribution to the organization's overall emphasis on a culture of reliability and system safety. In the field of organizational behavior the interactive model of social identity formation has been recently proposed to explain the process by which the internalization of shared norms and values occurs, an element critical in identity formation. Using this rich model of organizational behavior we analyzed multiple sources of data from nine new hires over a period of three years. This was done from the time they were employed to investigate the construction of social identity by new entrants entering into a complex organizational setting reflected in the context of a nuclear facility. Informed by our data analyses, we found support for the interactive model of social identity development and report the unexpected finding that a newly appointed member's age and level of experience appears to influence the manner in which they adapt, and assimilate into their surroundings. This study represents an important contribution to the safety and reliability literature as it provides a rich insight into the way newly recruited employees enact the process by which their identities are formed and hence act, particularly under conditions of duress or significant organizational disruption in complex organizational settings. - Highlights: • We examined how newly recruited nuclear engineer staff develop their social identity. • The study empirically examined the interactive model of social identity formation. • Innovative research strategies were used to capture rich primary data for all case studies. • Age and experience moderated internalization route and the social identity formation process

  3. A Mechanistic Model of Waterfall Plunge Pool Erosion into Bedrock

    Science.gov (United States)

    Scheingross, Joel S.; Lamb, Michael P.

    2017-11-01

    Landscapes often respond to changes in climate and tectonics through the formation and upstream propagation of knickzones composed of waterfalls. Little work has been done on the mechanics of waterfall erosion, and instead most landscape-scale models neglect waterfalls or use rules for river erosion, such as stream power, that may not be applicable to waterfalls. Here we develop a physically based model to predict waterfall plunge pool erosion into rock by abrasion from particle impacts and test the model against flume experiments. Both the model and experiments show that evolving plunge pools have initially high vertical erosion rates due to energetic particle impacts, and erosion slows and eventually ceases as pools deepen and deposition protects the pool floor from further erosion. Lateral erosion can continue after deposition on the pool floor, but it occurs at slow rates that become negligible as pools widen. Our work points to the importance of vertical drilling of successive plunge pools to drive upstream knickzone propagation in homogenous rock, rather than the classic mechanism of headwall undercutting. For a series of vertically drilling waterfalls, we find that upstream knickzone propagation is faster under higher combined water and sediment fluxes and for knickzones composed of many waterfalls that are closely spaced. Our model differs significantly from stream-power-based erosion rules in that steeper knickzones can retreat faster or more slowly depending on the number and spacing of waterfalls within a knickzone, which has implications for interpreting climatic and tectonic history through analysis of river longitudinal profiles.

  4. Mitochondrial deoxyribonucleoside triphosphate pools in thymidine kinase 2 deficiency.

    Science.gov (United States)

    Saada, Ann; Ben-Shalom, Efrat; Zyslin, Rivka; Miller, Chaya; Mandel, Hanna; Elpeleg, Orly

    2003-10-24

    Deficiency of mitochondrial thymidine kinase (TK2) is associated with mitochondrial DNA (mtDNA) depletion and manifests by severe skeletal myopathy in infancy. In order to elucidate the pathophysiology of this condition, mitochondrial deoxyribonucleoside triphosphate (dNTP) pools were determined in patients' fibroblasts. Despite normal mtDNA content and cytochrome c oxidase (COX) activity, mitochondrial dNTP pools were imbalanced. Specifically, deoxythymidine triphosphate (dTTP) content was markedly decreased, resulting in reduced dTTP:deoxycytidine triphosphate ratio. These findings underline the importance of balanced mitochondrial dNTP pools for mtDNA synthesis and may serve as the basis for future therapeutic interventions.

  5. Core-concrete molten pool dynamics and interfacial heat transfer

    International Nuclear Information System (INIS)

    Benjamin, A.S.

    1980-01-01

    Theoretical models are derived for the heat transfer from molten oxide pools to an underlying concrete surface and from molten steel pools to a general concrete containment. To accomplish this, two separate effects models are first developed, one emphasizing the vigorous agitation of the molten pool by gases evolving from the concrete and the other considering the insulating effect of a slag layer produced by concrete melting. The resulting algebraic expressions, combined into a general core-concrete heat transfer representation, are shown to provide very good agreement with experiments involving molten steel pours into concrete crucibles

  6. Gene Pools and the Genetic Architecture of Domesticated Cowpea

    Directory of Open Access Journals (Sweden)

    Bao-Lam Huynh

    2013-11-01

    Full Text Available Cowpea [ (L. Walp.] is a major tropical legume crop grown in warm to hot areas throughout the world and especially important to the people of sub-Saharan Africa where the crop was domesticated. To date, relatively little is understood about its domestication origins and patterns of genetic variation. In this study, a worldwide collection of cowpea landraces and African ancestral wild cowpea was genotyped with more than 1200 single nucleotide polymorphism markers. Bayesian inference revealed the presence of two major gene pools in cultivated cowpea in Africa. Landraces from gene pool 1 are mostly distributed in western Africa while the majority of gene pool 2 are located in eastern Africa. Each gene pool is most closely related to wild cowpea in the same geographic region, indicating divergent domestication processes leading to the formation of two gene pools. The total genetic variation within landraces from countries outside Africa was slightly greater than within African landraces. Accessions from Asia and Europe were more related to those from western Africa while accessions from the Americas appeared more closely related to those from eastern Africa. This delineation of cowpea germplasm into groups of genetic relatedness will be valuable for guiding introgression efforts in breeding programs and for improving the efficiency of germplasm management.

  7. Problems faced by newly diagnosed diabetes mellitus patients at ...

    African Journals Online (AJOL)

    Diabetes mellitus can be a frightening experience for newly diagnosed patients. The aim of this study was to determine and describe the problems faced by newly diagnosed diabetes mellitus patients at primary healthcare facilities at Mopani district, Limpopo Province. A qualitative, descriptive and contextual research ...

  8. Newly graduated nurses' use of knowledge sources in clinical decision-making

    DEFF Research Database (Denmark)

    Voldbjerg, Siri Lygum; Grønkjaer, Mette; Wiechula, Rick

    2017-01-01

    AIMS AND OBJECTIVES: To explore which knowledge sources newly graduated nurses' use in clinical decision-making and why and how they are used. BACKGROUND: In spite of an increased educational focus on skills and competencies within evidence based practice newly graduated nurses' ability to use...... approaches to strengthen the knowledgebase used in clinical decision-making. DESIGN AND METHODS: Ethnographic study using participant-observation and individual semi-structured interviews of nine Danish newly graduated nurses in medical and surgical hospital settings. RESULTS: Newly graduates use...... in clinical decision-making. If newly graduates are to be supported in an articulate and reflective use of a variety of sources, they have to be allocated to experienced nurses who model a reflective, articulate and balanced use of knowledge sources. This article is protected by copyright. All rights reserved....

  9. Experimental studies on condensation of steam mixed with noncondensable gas inside the vertical tube in a pool filled with subcooled water

    International Nuclear Information System (INIS)

    Maheshwari, N.K.; Saha, D.; Sinha, R.K.; Aritomi, M.

    2003-01-01

    A passive containment cooling system with immersed condensers has been proposed as one of the alternatives for the advanced heavy water reactor (AHWR) being designed in India. The system removes residual/decay heat released into the containment through the immersed condensers kept in a pool of water following loss of coolant accident. An important aspect of the immersed condensers is the potential degradation of its performance due to the presence of noncondensable gases. Experiments are performed to obtain reliable data on condensation phenomena in presence of air. These experiments are conducted on full-scale tubes of condensers immersed in a pool of water maintaining similar conditions as in the prototype of AHWR. A method has been proposed for the determination of the local heat transfer rate using correlations given in literature. The parametric effects of air mass fraction, pressure, steam flow, etc. on condensation heat transfer in presence of noncondensable gas have been studied. The experimental results are compared with the correlations given in literature. (orig.)

  10. Value of a newly sequenced bacterial genome

    DEFF Research Database (Denmark)

    Barbosa, Eudes; Aburjaile, Flavia F; Ramos, Rommel Tj

    2014-01-01

    and annotation will not be undertaken. It is important to know what is lost when we settle for a draft genome and to determine the "scientific value" of a newly sequenced genome. This review addresses the expected impact of newly sequenced genomes on antibacterial discovery and vaccinology. Also, it discusses...... heightened expectations that NGS would boost antibacterial discovery and vaccine development. Although many possible drug and vaccine targets have been discovered, the success rate of genome-based analysis has remained below expectations. Furthermore, NGS has had consequences for genome quality, resulting...

  11. Crimpy enables discrimination of pre and postsynaptic pools of a BMP at the Drosophila NMJ

    Science.gov (United States)

    James, Rebecca E.; Hoover, Kendall M.; Bulgari, Dinara; McLaughlin, Colleen N.; Wilson, Christopher G.; Wharton, Kristi A.; Levitan, Edwin S.; Broihier, Heather T.

    2014-01-01

    Summary Distinct pools of the BMP Glass bottom boat (Gbb) control structure and function of the Drosophila neuromuscular junction. Specifically, motoneuron-derived Gbb regulates baseline neurotransmitter release, while muscle-derived Gbb regulates NMJ growth. Yet how cells differentiate between these ligand pools is not known. Here we present evidence that the neuronal Gbb-binding protein Crimpy (Cmpy) permits discrimination of pre and postsynaptic ligand by serving sequential functions in Gbb signaling. Cmpy first delivers Gbb to dense core vesicles (DCVs) for activity-dependent release from presynaptic terminals. In the absence of Cmpy, Gbb is no longer associated with DCVs and is not released by activity. Electrophysiological analyses demonstrate that Cmpy promotes Gbb's pro-neurotransmission function. Surprisingly, the Cmpy ectodomain is itself released upon DCV exocytosis, arguing that Cmpy serves a second function in BMP signaling. In addition to trafficking Gbb to DCVs, we propose that Gbb/Cmpy co-release from presynaptic terminals defines a neuronal pro-transmission signal. PMID:25453556

  12. LCG Persistency Framework (POOL, CORAL, COOL) - Status and Outlook

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The LCG Persistency Framework consists of three software packages (POOL, CORAL and COOL) that address the data access requirements of the LHC experiments in several different areas. The project is the result of the collaboration between the CERN IT Department and the three experiments (ATLAS, CMS and LHCb) that are using some or all of the Persistency Framework components to access their data. The POOL package is a hybrid technology store for C++ objects, using a mixture of streaming and relational technologies to implement both object persistency and object metadata catalogs and collections. POOL provides generic components that can be used by the experiments to store both their event data and their conditions data. The CORAL package is an abstraction layer with an SQL-free API for accessing data stored using relational database technologies. It is used directly by experiment-specific applications and internally by both COOL and POOL. The COOL package provides specific software components and tools for the h...

  13. The burning and smoke release rates of sodium pool fires

    International Nuclear Information System (INIS)

    Newman, R.N.; Payne, J.F.B.

    1976-10-01

    The burning rates and smoke release fractions of sodium pool fires have been measured over the pool temperature range 250 0 C to 750 0 C. A theoretical model is derived which satisfactorily predicts the burning rate over the above temperature range. The theory further predicts that the burning rate should be independent of pool diameter, a prediction supported by a comparison of burning rate data from this study and available data from other studies. (author)

  14. Biophysical Interactions within Step-Pool Mountain Streams Following Wildfire

    Science.gov (United States)

    Parker, A.; Chin, A.; O'Dowd, A. P.

    2014-12-01

    Recovery of riverine ecosystems following disturbance is driven by a variety of interacting processes. Wildfires pose increasing disturbances to riverine landscapes, with rising frequencies and magnitudes owing to warming climates and increased fuel loads. The effects of wildfire include loss of vegetation, elevated runoff and flash floods, erosion and deposition, and changing biological habitats and communities. Understanding process interactions in post-fire landscapes is increasingly urgent for successful management and restoration of affected ecosystems. In steep channels, steps and pools provide prominent habitats for organisms and structural integrity in high energy environments. Step-pools are typically stable, responding to extreme events with recurrence intervals often exceeding 50 years. Once wildfire occurs, however, intensification of post-fire flood events can potentially overpower the inherent stability of these systems, with significant consequences for aquatic life and human well-being downstream. This study examined the short-term response of step-pool streams following the 2012 Waldo Canyon Fire in Colorado. We explored interacting feedbacks among geomorphology, hydrology, and ecology in the post-fire environment. At selected sites with varying burn severity, we established baseline conditions immediately after the fire with channel surveys, biological assessment using benthic macroinvertebrates, sediment analysis including pebble counts, and precipitation gauging. Repeat measurements after major storm events over several years enabled analysis of the interacting feedbacks among post-fire processes. We found that channels able to retain the step-pool structure changed less and facilitated recovery more readily. Step habitats maintained higher percentages of sensitive macroinvertebrate taxa compared to pools through post-fire floods. Sites burned with high severity experienced greater reduction in the percentage of sensitive taxa. The decimation of

  15. Wastewater treatment in a compact intensified wetland system at the Badboot: a floating swimming pool in Belgium.

    Science.gov (United States)

    Van Oirschot, D; Wallace, S; Van Deun, R

    2015-09-01

    The Badboot (Dutch for swimming pool boat) is a floating swimming pool located in the city center of Antwerp in Belgium. The overall design consists of a recycled ferry boat that serves as a restaurant and next to that a newly built ship that harbours an Olympic size swimming pool, sun decks, locker rooms with showers, and a party space. A major design goal of the project was to make the ship as environmentally friendly as possible. To avoid discharge of contaminated waste water in the Antwerp docks, the ship includes onsite treatment of wastewater in a compact constructed wetland. The treatment wetland system was designed to treat wastewater from visitor locker rooms, showers, toilets, two bars, and the wastewater from the restaurant kitchen. Due to the limited space on board the ship, only 188 m(2) could be allocated to a wetland treatment system. As a result, part of the design included intensification of the wetland treatment process through the use of Forced Bed Aeration, which injects small quantities of air in a very uniform grid pattern throughout the wetland with a mechanical air compressor. The system was monitored between August 2012 and March 2013 (with additional sampling in the autumn of 2014). Flows and loads to the wetland were highly variable, but removal efficiency was extremely high; 99.5 % for chemical oxygen demand (COD), 88.6 % for total nitrogen and 97.2 % for ammonia. The treatment performance was assessed using a first-order, tanks-in-series model (the P-k-C* model) and found to be roughly equivalent to similar intensified wetlands operating in Germany. However, treatment performance was substantially better than data reported on passive wetlands, likely as a result of intensification. Even with mechanically assisted aeration, the total oxygen delivered to the treatment wetlands was insufficient to support conventional nitrification and denitrification, so it is likely that alternate nitrogen removal pathways, such as anammox, are

  16. Fragmentation of a single molten copper and silver droplets penetrating a sodium pool with solid crust

    International Nuclear Information System (INIS)

    Wataru Itagaki; Ken-ichiro Sugiyama; Satoshi Nishimura; Izumi Kinoshita

    2005-01-01

    As a basic study of molten fuel-coolant interaction in liquid metal fast cooled reactors, we carried out a series of experiments for the fragmentation of molten copper droplet penetrating sodium pool at instantaneous contact interface temperatures below its freezing point. A single molten copper droplet with 5g in weight and with superheating varied from 0 degree C to 131 degree C was dropped into a sodium pool in a wide range of ambient Weber numbers 24 to 228. In addition to the experiment of molten copper droplet, molten silver droplet with 5gs in weight and with superheating varied from 3 degree C to 174 degree C was dropped into the sodium pool at an ambient Weber number of about 80. From the observation of the cross section of solidified silver droplet without fragmentation, it was clearly confirmed that sodium micro jet is driven into the inside from the upper surface of molten droplet keeping liquid phase, which is clear evidence for the thermal fragmentation mechanism proposed in the previous paper. Large scattering in the values of dimensionless mass median diameter observed in the present experimental study is recognized to be dependent on whether latent heat instantaneously released due to the injection of sodium micro jet can be effectively utilized for fragmentation. (authors)

  17. Research progresses and future directions on pool boiling heat transfer

    Directory of Open Access Journals (Sweden)

    M. Kumar

    2015-12-01

    Full Text Available This paper reviews the previous work carried on pool boiling heat transfer during heating of various liquids and commodities categorized as refrigerants and dielectric fluids, pure liquids, nanofluids, hydrocarbons and additive mixtures, as well as natural and synthetic colloidal solutions. Nucleate pool boiling is an efficient and effective method of boiling because high heat fluxes are possible with moderate temperature differences. It is characterized by the growth of bubbles on a heated surface. It occurs during boiling of liquids for excess temperature ranging from 5 to 30 °C in various processes related to high vaporization of liquid for specific purposes like sugarcane juice heating for jaggery making, milk heating for khoa making, steam generation, cooling of electronic equipments, refrigeration and etcetera. In this review paper, pool boiling method during heating of liquids for specific purpose is depicted. It is inferred that enhancement in pool boiling heat transfer is a challenging and complex task. Also, recent research and use of various correlations for natural convection pool boiling is reviewed.

  18. A cross-sectional study of leukopenia and thrombocytopenia among Chinese adults with newly diagnosed HIV/AIDS.

    Science.gov (United States)

    Shen, Yinzhong; Wang, Jiangrong; Wang, Zhenyan; Shen, Jiayin; Tangkai Qi; Song, Wei; Tang, Yang; Liu, Li; Zhang, Renfang; Zeng, Yi; Lu, Hongzhou

    2015-04-01

    We conducted a cross-sectional study to determine the prevalence and risk factors of leukopenia and thrombocytopenia among Chinese adults with newly diagnosed HIV/AIDS. One thousand nine hundred and forty-eight newly diagnosed HIV-infected patients were enrolled between 2009 and 2010. Serum samples obtained from each individual were collected for complete blood count. Factors associated with the presence of leukopenia and thrombocytopenia were analyzed by multiple logistic regression. The overall prevalence of leukopenia and of thrombocytopenia was 33.2% and 15.6%, respectively. The prevalence of leukopenia was higher among females than among males (39.4% versus 31.2%). The prevalence of leukopenia increased with decreasing CD4 count (8.2%, 26.5%, 33.4%, and 41.5% among patients with CD4 count of ≥ 350, 200-349, 50-199, and risk of leukopenia, and that lower CD4 count, and HIV transmission by blood were significantly associated with an increased risk of thrombocytopenia. The study reflects that leukopenia and thrombocytopenia are common among Chinese adults with newly diagnosed HIV/AIDS; and lower CD4 count is associated with an increased risk of both leukopenia and thrombocytopenia. We propose that a routine assessment of these parameters is necessary for timely and adequate clinical management.

  19. Safety analysis of a pool Genesis II irradiator

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de A.

    2011-01-01

    The Genesis II Irradiator manufactured by GRAT * STAR Inc. (USA) is a category III gamma irradiator in which the sealed source is contained in a water filled storage pool and is shielded permanently, i.e. the material has to move down to the source. Even though the pool is 5.6 m deep, what would happen if the water level lowered? There are a series of safety devices that will avoid this situation and calculations show that the water level has to be very low in order to deliver a significant dose; moreover, only in case a person remains at the border of the pool for a long time this would be risky. In conclusion, it is practically impossible for someone to be exposed to radiation from a Genesis II Irradiator source. (author)

  20. CAREM-25. Suppression Pool Cooling and Purification System

    International Nuclear Information System (INIS)

    Carlevaris, Rodolfo; Palmerio, D.; Patrignani, A.; Quiroz, H.; Ramilo, L.; Vindrola, C.

    2000-01-01

    The Suppression Pool Cooling and Purification System has the following main functions: purify and cool water from the Suppression Pool, cool and send water to the Residual Heat Extraction System, and transfer water to the Fuel Element Transference Channel. In case of Loss of Coolant Accident (LOCA), the system sends water from the Suppression Pool to the spray network, thus cooling and reducing pressure in the primary containment.The system has been designed in accordance with the requirements of the following standards ANSI/ANS 52.1 [1], ANSI/ANS 57.2 [2], ANSI/ANS 56.2 [3], ANSI/ANS 59.1 [4] ANSI/ANS 58.3 [5], ANSI/ANS 58.9 [6], and ANSI/ANS 56.5 [7]. The design of the system fulfils all the assigned functions

  1. Pooled biological specimens for human biomonitoring of environmental chemicals: opportunities and limitations.

    Science.gov (United States)

    Heffernan, Amy L; Aylward, Lesa L; Toms, Leisa-Maree L; Sly, Peter D; Macleod, Matthew; Mueller, Jochen F

    2014-01-01

    Biomonitoring has become the "gold standard" in assessing chemical exposures, and has an important role in risk assessment. The pooling of biological specimens-combining multiple individual specimens into a single sample-can be used in biomonitoring studies to monitor levels of exposure and identify exposure trends or to identify susceptible populations in a cost-effective manner. Pooled samples provide an estimate of central tendency and may also reveal information about variation within the population. The development of a pooling strategy requires careful consideration of the type and number of samples collected, the number of pools required and the number of specimens to combine per pool in order to maximise the type and robustness of the data. Creative pooling strategies can be used to explore exposure-outcome associations, and extrapolation from other larger studies can be useful in identifying elevated exposures in specific individuals. The use of pooled specimens is advantageous as it saves significantly on analytical costs, may reduce the time and resources required for recruitment and, in certain circumstances, allows quantification of samples approaching the limit of detection. In addition, the use of pooled samples can provide population estimates while avoiding ethical difficulties that may be associated with reporting individual results.

  2. High-Order Local Pooling and Encoding Gaussians Over a Dictionary of Gaussians.

    Science.gov (United States)

    Li, Peihua; Zeng, Hui; Wang, Qilong; Shiu, Simon C K; Zhang, Lei

    2017-07-01

    Local pooling (LP) in configuration (feature) space proposed by Boureau et al. explicitly restricts similar features to be aggregated, which can preserve as much discriminative information as possible. At the time it appeared, this method combined with sparse coding achieved competitive classification results with only a small dictionary. However, its performance lags far behind the state-of-the-art results as only the zero-order information is exploited. Inspired by the success of high-order statistical information in existing advanced feature coding or pooling methods, we make an attempt to address the limitation of LP. To this end, we present a novel method called high-order LP (HO-LP) to leverage the information higher than the zero-order one. Our idea is intuitively simple: we compute the first- and second-order statistics per configuration bin and model them as a Gaussian. Accordingly, we employ a collection of Gaussians as visual words to represent the universal probability distribution of features from all classes. Our problem is naturally formulated as encoding Gaussians over a dictionary of Gaussians as visual words. This problem, however, is challenging since the space of Gaussians is not a Euclidean space but forms a Riemannian manifold. We address this challenge by mapping Gaussians into the Euclidean space, which enables us to perform coding with common Euclidean operations rather than complex and often expensive Riemannian operations. Our HO-LP preserves the advantages of the original LP: pooling only similar features and using a small dictionary. Meanwhile, it achieves very promising performance on standard benchmarks, with either conventional, hand-engineered features or deep learning-based features.

  3. Phytomass carbon pool of trees and forests in India

    NARCIS (Netherlands)

    Kaul, M.; Mohren, G.M.J.; Dadhwal, V.K.

    2011-01-01

    The study reports estimates of above ground phytomass carbon pools in Indian forests for 1992 and 2002 using two different methodologies. The first estimate was derived from remote sensing based forest area and crown density estimates, and growing stock data for 1992 and 2002 and the estimated pool

  4. Experimental characterization of the weld pool flow in a TIG configuration

    Science.gov (United States)

    Stadler, M.; Masquère, M.; Freton, P.; Franceries, X.; Gonzalez, J. J.

    2014-11-01

    Tungsten Inert Gas (TIG) welding process relies on heat transfer between plasma and work piece leading to a metallic weld pool. Combination of different forces produces movements on the molten pool surface. One of our aims is to determine the velocity on the weld pool surface. This provides a set of data that leads to a deeper comprehension of the flow behavior and allows us to validate numerical models used to study TIG parameters. In this paper, two diagnostic methods developed with high speed imaging for the determination of velocity of an AISI 304L stainless steel molten pool are presented. Application of the two methods to a metallic weld pool under helium with a current intensity of 100 A provides velocity values around 0.70 m/s which are in good agreement with literature works.

  5. Zooplankton at deep Red Sea brine pools

    KAUST Repository

    Kaartvedt, Stein

    2016-03-02

    The deep-sea anoxic brines of the Red Sea comprise unique, complex and extreme habitats. These environments are too harsh for metazoans, while the brine–seawater interface harbors dense microbial populations. We investigated the adjacent pelagic fauna at two brine pools using net tows, video records from a remotely operated vehicle and submerged echosounders. Waters just above the brine pool of Atlantis II Deep (2000 m depth) appeared depleted of macrofauna. In contrast, the fauna appeared to be enriched at the Kebrit Deep brine–seawater interface (1466 m).

  6. Mathematical modelling and simulation of the thermal performance of a solar heated indoor swimming pool

    Directory of Open Access Journals (Sweden)

    Mančić Marko V.

    2014-01-01

    Full Text Available Buildings with indoor swimming pools have a large energy footprint. The source of major energy loss is the swimming pool hall where air humidity is increased by evaporation from the pool water surface. This increases energy consumption for heating and ventilation of the pool hall, fresh water supply loss and heat demand for pool water heating. In this paper, a mathematical model of the swimming pool was made to assess energy demands of an indoor swimming pool building. The mathematical model of the swimming pool is used with the created multi-zone building model in TRNSYS software to determine pool hall energy demand and pool losses. Energy loss for pool water and pool hall heating and ventilation are analyzed for different target pool water and air temperatures. The simulation showed that pool water heating accounts for around 22%, whereas heating and ventilation of the pool hall for around 60% of the total pool hall heat demand. With a change of preset controller air and water temperatures in simulations, evaporation loss was in the range 46-54% of the total pool losses. A solar thermal sanitary hot water system was modelled and simulated to analyze it's potential for energy savings of the presented demand side model. The simulation showed that up to 87% of water heating demands could be met by the solar thermal system, while avoiding stagnation. [Projekat Ministarstva nauke Republike Srbije, br. III 42006: Research and development of energy and environmentally highly effective polygeneration systems based on using renewable energy sources

  7. High efficiency pool filtering systems utilising variable frequency drives

    Energy Technology Data Exchange (ETDEWEB)

    Hameiri, Z.; Sproul, A.B. [School of Photovoltaic and Renewable Energy Engineering, UNSW, Sydney, NSW 2052 (Australia); Spooner, T. [School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia)

    2009-02-15

    Over 1 year, private swimming pools in Australia will typically consume 1680 GWh of electricity, producing 2130 kt of CO{sub 2}. Redesigning a pool's filtration system and using it more efficiently can reduce the energy use, and hence the CO{sub 2} production, by a significant amount. This paper describes experimental measurements carried out on a new design of pool pump system. Initial experiments using a variable frequency drive (VFD) with a standard, single phase pump/motor system have achieved energy savings of 40%. Utilising a VFD and a three phase pump/motor energy savings of 61% have been achieved, without degrading the system performance. (author)

  8. Cryptosporidium and Giardia in Swimming Pools, Atlanta, Georgia

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dan Rutz speaks with Dr. Joan Shields, a guest researcher with the Healthy Swimming Program at CDC, about an article in June 2008 issue of Emerging Infectious Diseases reporting on the results of a test of swimming pools in the greater Atlanta, Georgia area. Dr. Shields tested 160 pools in metro Atlanta last year for Cryptosporidium and Giardia. These germs cause most recreational water associated outbreaks.

  9. Interfacial energies of aqueous mixtures and porous coverings for enhancing pool boiling heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Melendez, Elva [CIICAp, Universidad Autonoma del Estado de Morelos, 62210 (Mexico); Reyes, Rene [Departamento de Ingenieria Quimica y Alimentos, Universidad de las Americas Puebla, Santa Catarina Martir Cholula, Puebla 72820 (Mexico)

    2006-08-15

    The interfacial energies effects on pool boiling were measured for combinations of aqueous ethanol mixtures and cationic surfactants. The mixture with 16% ethanol by weight had the lowest contact angle (associated to the highest wettability) and produced the highest convective heat transfer coefficient, h, among the aqueous ethanol mixtures. The surfactant sodium-lauryl-sulfate added at 100 ppm (its calculated critical micelle concentration CMC) to the 16% ethanol aqueous mixture produced an additional increment of the wettability of the mixture and of the h values; other concentrations of the surfactant reduced de contact angle and h values. The effect of these interfacial energies represents a mass-transfer contribution to pool boiling and the proposal of mixture effects both as increased spreadability and as micelle states. Several randomly constructed porous coverings, contributing to the breakage of vapor slugs around the heater, were tested; produced the highest h values for average pore diameters of 0.5 mm, and covering thickness of 0.972 mm. The synergistic effect on h of the interfacial energies of mixtures at their critical micelle concentration, and porous coverings was measured. Therefore, the independent driving forces combined in this study for increasing pool boiling heat transfer are (a) spreadability of the liquid on the solid; (b) the bubble's size reduction, achieved by micelle states; and (c) the bubble's breakage, induced by the porous coverings, for vapor flow not under pressure drop control. (author)

  10. Comparison of fecal pooling strategies for detection of Mycobacterium avium ssp. paratuberculosis in cattle.

    Science.gov (United States)

    McKenna, S L B; Ritter, C; Dohoo, I; Keefe, G P; Barkema, H W

    2018-05-23

    In herds with typical moderate to low within-herd prevalence, testing for Mycobacterium avium ssp. paratuberculosis (MAP), the infectious agent of Johne's disease, will be more cost-effective if individual fecal samples are cultured in composite pools. However, sensitivity to classify a pool containing 1 or more positive individual samples as positive may depend on pool size and number of individual positive samples within a pool. Fecal samples collected from 994 dairy cows sampled at slaughter were cultured to detect MAP. Culturing was done both individually and as composite pooled samples using the TREK ESP Culture System II broth medium (Thermo Fisher Scientific, Trek Diagnostic Systems Inc., Cleveland, OH). Composite samples consisted of pools containing feces from 3, 5, 8, 10, or 15 cows. The number of individual fecal culture-positive cows within each pool ranged from 0 to 4. Culture of individual fecal samples detected MAP in 36 (3.6%) of the 994 cows. Individual samples that were detected within the first 50 d by TREK ESP Culture System II were more likely to lead to a positive pool result. In total, 840 pooled fecal samples were examined for presence of MAP, and of those, 272 pools actually contained feces from fecal culture-positive cows. The crude sensitivity (proportion of pools that contained at least 1 fecal-positive cow that tested positive) for pools of 3, 5, 8, 10, and 15 was 47, 67, 44, 59, and 39%, respectively. Across pools, an increase of the number of fecal culture-positive samples from 1 to 2 enhanced overall crude sensitivity from 44 to 71%. However, sensitivity did not further increase for pools with 3 or 4 fecal culture-positive samples (63 and 60%, respectively). Additionally, a simulation analysis assessing probability of pooled fecal samples being positive in herds of 50 and 100 cows was conducted. The simulation assumed that 1, 2, or 5 cows per herd were MAP fecal culture-positive and that pools of 5 and 10 were used. This low

  11. Ecologically sustainable but unjust? Negotiating equity and authority in common-pool marine resource management

    Directory of Open Access Journals (Sweden)

    Sarah C. Klain

    2014-12-01

    Full Text Available Under appropriate conditions, community-based fisheries management can support sound resource stewardship, with positive social and environmental outcomes. Evaluating indigenous peoples' involvement in commercial sea cucumber and geoduck fisheries on the central coast of British Columbia, Canada, we found that the current social-ecological system configuration is relatively ecologically sustainable according to stock assessments. However, the current system also results in perceived inequities in decision-making processes, harvesting allocations, and socioeconomic benefits. As a result, local coastal resource managers envision a transformation of sea cucumber and geoduck fisheries governance and management institutions. We assessed the potential robustness of the proposed institutions using Elinor Ostrom's common-pool resource design principles. Grounded in the region's legal, political, and historical context, our analysis suggests that greater local involvement in these invertebrate fisheries and their management could provide more benefits to local communities than the status quo while maintaining an ecologically sustainable resource. Our research highlights the importance of explicitly addressing historical context and equity considerations in social-ecological system analyses and when renegotiating the institutions governing common-pool resources.

  12. Strong influence of regional species pools on continent-wide structuring of local communities

    DEFF Research Database (Denmark)

    Lessard, Jean-Philippe; Borregaard, Michael Krabbe; Fordyce, James A.

    2012-01-01

    pool, to examine the interplay between broad-scale evolutionary and fine-scale ecological processes. Finally, a renewed interest in the influence of species source pools on communities has shown that the definition of the source pool influences interpretations of patterns of community structure. We use...... of communities along climatic gradients. We find that the average phylogenetic relatedness of species in ant communities decreases from tropical to temperate regions, but the strength of this relationship depends on the level of ecological realism in the definition of source pools. We conclude that the evolution...... of climatic niches influences the phylogenetic structure of regional source pools and that the influence of regional source pools on local community structure is strong....

  13. Heat and fission product transport in molten core material pool with crust

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2005-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the reactor vessel during a severe accident. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool is estimated by product of the mass concentration and energy conversion factor of each fission product. Twenty-nine elements are chosen and classified by their chemical properties to calculate heat generation rate in the pool. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis is performed for heat and fission product transport in a molten core material pool during the Three Mile Island Unit 2 (TMI-2) accident. The pool is assumed to be a partially filled hemisphere, whose change in geometry is neglected during the numerical calculation. Calculated results indicate that the peak temperature in the molten pool is significantly lowered, since a substantial amount of the volatile fission products is released from the molten pool during progression of the accident. The results may directly be applied to the existing severe accident analysis codes to more mechanistically determine the thermal load to the reactor vessel lower head during the in-vessel retention

  14. A protocol for measuring spatial variables in soft-sediment tide pools

    Directory of Open Access Journals (Sweden)

    Marina R. Brenha-Nunes

    2016-01-01

    Full Text Available ABSTRACT We present a protocol for measuring spatial variables in large (>50 m2 soft-sediment tide pool. Secondarily, we present the fish capture efficiency of a sampling protocol that based on such spatial variables to calculate relative abundances. The area of the pool is estimated by summing areas of basic geometric forms; the depth, by taken representative measurements of the depth variability of each pool's sector, previously determined according to its perimeter; and the volume, by considering the pool as a prism. These procedures were a trade-off between the acquisition of reliable estimates and the minimization of both the cost of operating and the time spent in field. The fish sampling protocol is based on two con secutive stages: 1 two people search for fishes under structures (e.g., rocks and litters on the pool and capture them with hand seines; 2 these structures are removed and then a beach-seine is hauled over the whole pool. Our method is cheaper than others and fast to operate considering the time in low tides. The method to sample fish is quite efficient resulting in a capture efficiency of 89%.

  15. Afterlife of a Drop Impacting a Liquid Pool

    Science.gov (United States)

    Saha, Abhishek; Wei, Yanju; Tang, Xiaoyu; Law, Chung K.

    2017-11-01

    Drop impact on liquid pool is ubiquitous in industrial processes, such as inkjet printing and spray coating. While merging of drop with the impacted liquid surface is essential to facilitate the printing and coating processes, it is the afterlife of this merged drop and associated mixing which control the quality of the printed or coated surface. In this talk we will report an experimental study on the structural evolution of the merged droplet inside the liquid pool. First, we will analyze the depth of the crater created on the pool surface by the impacted drop for a range of impact inertia, and we will derive a scaling relation and the associated characteristic time-scale. Next, we will focus on the toroidal vortex formed by the moving drop inside the liquid pool and assess the characteristic time and length scales of the penetration process. The geometry of the vortex structure which qualitatively indicates the degree of mixedness will also be discussed. Finally, we will present the results from experiments with various viscosities to demonstrate the role of viscous dissipation on the geometry and structure formed by the drop. This work is supported by the Army Research Office and the Xerox Corporation.

  16. Native Seed Supply and the Restoration Species Pool.

    Science.gov (United States)

    Ladouceur, Emma; Jiménez-Alfaro, Borja; Marin, Maria; De Vitis, Marcello; Abbandonato, Holly; Iannetta, Pietro P M; Bonomi, Costantino; Pritchard, Hugh W

    2018-01-01

    Globally, annual expenditure on ecological restoration of degraded areas for habitat improvement and biodiversity conservation is approximately $18bn. Seed farming of native plant species is crucial to meet restoration goals, but may be stymied by the disconnection of academic research in seed science and the lack of effective policies that regulate native seed production/supply. To illustrate this problem, we identified 1,122 plant species important for European grasslands of conservation concern and found that only 32% have both fundamental seed germination data available and can be purchased as seed. The " restoration species pool," or set of species available in practice, acts as a significant biodiversity selection filter for species use in restoration projects. For improvement, we propose: (1) substantial expansion of research and development on native seed quality, viability, and production; (2) open-source knowledge transfer between sectors; and (3) creation of supportive policy intended to stimulate demand for biodiverse seed.

  17. Strong influence of regional species pools on continent-wide structuring of local communities.

    Science.gov (United States)

    Lessard, Jean-Philippe; Borregaard, Michael K; Fordyce, James A; Rahbek, Carsten; Weiser, Michael D; Dunn, Robert R; Sanders, Nathan J

    2012-01-22

    There is a long tradition in ecology of evaluating the relative contribution of the regional species pool and local interactions on the structure of local communities. Similarly, a growing number of studies assess the phylogenetic structure of communities, relative to that in the regional species pool, to examine the interplay between broad-scale evolutionary and fine-scale ecological processes. Finally, a renewed interest in the influence of species source pools on communities has shown that the definition of the source pool influences interpretations of patterns of community structure. We use a continent-wide dataset of local ant communities and implement ecologically explicit source pool definitions to examine the relative importance of regional species pools and local interactions for shaping community structure. Then we assess which factors underlie systematic variation in the structure of communities along climatic gradients. We find that the average phylogenetic relatedness of species in ant communities decreases from tropical to temperate regions, but the strength of this relationship depends on the level of ecological realism in the definition of source pools. We conclude that the evolution of climatic niches influences the phylogenetic structure of regional source pools and that the influence of regional source pools on local community structure is strong.

  18. Gene pool conservation of teak in Myanmar

    International Nuclear Information System (INIS)

    Tin-Tun

    1995-01-01

    Myanmar with an area of 261, 228 Sq. miles is endowed with various types of forests which occupied nearly 50% of the country. Teak (Tectona grandis Linn. f.) is one of the most valuable timber species for its excellent wood quality and properties which are not observed with other timbers. Gene pool can be defined as a group of individual trees growing over a wide range of environmental conditions, and constituting different genetic complexes which can be transmitted to the offsprings. Topics such as: objectives of gene pool conservation, genetically improved seeds for large scale forest plantations, methodology of conservation, are discussed in the article. Myanmar teak dominates the world's teak market, and thus it is crucial to maintain the superiority in the conservation of gene complexes of teak. To some extent, the conservation of gene pools of teak and tree improvements are being undertaken by the Forest Research Institute of Myanmar. It is felt that the dissemination of the philosophy and concept of gene conservation to the personal involved in the forestry activities of the country are still inadequate

  19. Frozen gene pools - A future for species otherwise destined for extinction

    Science.gov (United States)

    Gee, G.F.

    1986-01-01

    Conclusion: Semen banks and ova and embryo banks can be practical methods to maintain gene pools. Gene pool preservation is desperately needed today due to the rapid decline in number of species and their habitat, a matter that is of concern to.biologists, economists, and politicians worldwide. Techniques are available for the cryopreservation of semen from many animals (and embryos from a few mammals) and adaptations of these techniques to other animals should be possible. A frozen gene pool in conjunction with existing programs makes it possible to preserve gene pools at less cost or in.some cases where no other alternative to extinction existed.

  20. Sculpting the Barnyard Gene Pool

    Science.gov (United States)

    Childers, Gina; Wolfe, Kim; Dupree, Alan; Young, Sheila; Caver, Jessica; Quintanilla, Ruby; Thornton, Laura

    2016-01-01

    Project-based learning (PBL) takes student engagement to a higher level through reflective collaboration, inquiry, critical thinking, problem solving, and personal relevance. This article explains how six high school teachers developed an interconnected, interdisciplinary STEM-focused PBL called "Sculpting the Barnyard Gene Pool." The…

  1. Newly Generated Liquid Waste Processing Alternatives Study, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Landman, William Henry; Bates, Steven Odum; Bonnema, Bruce Edward; Palmer, Stanley Leland; Podgorney, Anna Kristine; Walsh, Stephanie

    2002-09-01

    This report identifies and evaluates three options for treating newly generated liquid waste at the Idaho Nuclear Technology and Engineering Center of the Idaho National Engineering and Environmental Laboratory. The three options are: (a) treat the waste using processing facilities designed for treating sodium-bearing waste, (b) treat the waste using subcontractor-supplied mobile systems, or (c) treat the waste using a special facility designed and constructed for that purpose. In studying these options, engineers concluded that the best approach is to store the newly generated liquid waste until a sodium-bearing waste treatment facility is available and then to co-process the stored inventory of the newly generated waste with the sodium-bearing waste. After the sodium-bearing waste facility completes its mission, two paths are available. The newly generated liquid waste could be treated using the subcontractor-supplied system or the sodium-bearing waste facility or a portion of it. The final decision depends on the design of the sodium-bearing waste treatment facility, which will be completed in coming years.

  2. Melanocortin-1 receptor, skin cancer and phenotypic characteristics (M-SKIP project: study design and methods for pooling results of genetic epidemiological studies

    Directory of Open Access Journals (Sweden)

    Raimondi Sara

    2012-08-01

    Full Text Available Abstract Background For complex diseases like cancer, pooled-analysis of individual data represents a powerful tool to investigate the joint contribution of genetic, phenotypic and environmental factors to the development of a disease. Pooled-analysis of epidemiological studies has many advantages over meta-analysis, and preliminary results may be obtained faster and with lower costs than with prospective consortia. Design and methods Based on our experience with the study design of the Melanocortin-1 receptor (MC1R gene, SKin cancer and Phenotypic characteristics (M-SKIP project, we describe the most important steps in planning and conducting a pooled-analysis of genetic epidemiological studies. We then present the statistical analysis plan that we are going to apply, giving particular attention to methods of analysis recently proposed to account for between-study heterogeneity and to explore the joint contribution of genetic, phenotypic and environmental factors in the development of a disease. Within the M-SKIP project, data on 10,959 skin cancer cases and 14,785 controls from 31 international investigators were checked for quality and recoded for standardization. We first proposed to fit the aggregated data with random-effects logistic regression models. However, for the M-SKIP project, a two-stage analysis will be preferred to overcome the problem regarding the availability of different study covariates. The joint contribution of MC1R variants and phenotypic characteristics to skin cancer development will be studied via logic regression modeling. Discussion Methodological guidelines to correctly design and conduct pooled-analyses are needed to facilitate application of such methods, thus providing a better summary of the actual findings on specific fields.

  3. Melanocortin-1 receptor, skin cancer and phenotypic characteristics (M-SKIP) project: study design and methods for pooling results of genetic epidemiological studies

    Science.gov (United States)

    2012-01-01

    Background For complex diseases like cancer, pooled-analysis of individual data represents a powerful tool to investigate the joint contribution of genetic, phenotypic and environmental factors to the development of a disease. Pooled-analysis of epidemiological studies has many advantages over meta-analysis, and preliminary results may be obtained faster and with lower costs than with prospective consortia. Design and methods Based on our experience with the study design of the Melanocortin-1 receptor (MC1R) gene, SKin cancer and Phenotypic characteristics (M-SKIP) project, we describe the most important steps in planning and conducting a pooled-analysis of genetic epidemiological studies. We then present the statistical analysis plan that we are going to apply, giving particular attention to methods of analysis recently proposed to account for between-study heterogeneity and to explore the joint contribution of genetic, phenotypic and environmental factors in the development of a disease. Within the M-SKIP project, data on 10,959 skin cancer cases and 14,785 controls from 31 international investigators were checked for quality and recoded for standardization. We first proposed to fit the aggregated data with random-effects logistic regression models. However, for the M-SKIP project, a two-stage analysis will be preferred to overcome the problem regarding the availability of different study covariates. The joint contribution of MC1R variants and phenotypic characteristics to skin cancer development will be studied via logic regression modeling. Discussion Methodological guidelines to correctly design and conduct pooled-analyses are needed to facilitate application of such methods, thus providing a better summary of the actual findings on specific fields. PMID:22862891

  4. Survey of bacterial contamination of environment of swimming pools in Yazd city, in 2013

    Directory of Open Access Journals (Sweden)

    Hossein Jafari Mansoorian

    2015-09-01

    Full Text Available Background: Infections are readily transmitted as a result of bacterial contamination of swimming pools. Therefore, hygiene and preventing the contamination of swimming pools is of particular importance. The objective of this study was to determine the amount of bacterial contamination in indoor pools of Yazd in 2013. Methods: In this descriptive and analytical study, all indoor swimming pools of Yazd (12 pools were evaluated during the spring and summer of 2013, in terms of bacterial contamination. In order to determine contamination, a sterile cotton swab was used for sampling. On average, 45 samples were taken from different surfaces in each pool (shower, dressing room, sitting places in sauna, platforms and around the pool. In total, about 540 samples from all pools were tested for bacterial contamination. Results: The results show that from 540 samples, bacterial contamination was observed in about 93 samples (17.22%; and was seen more in showers, edges of the pool and jacuzzis, and the slippers used in swimming pools. The most important isolated bacteria types were E. coli, Actinobacteria, Pseudomonas alcaligenes, Pseudomonas aeruginosa and Klebsiella pneumonia. Conclusion: The results indicate the presence of bacterial contamination on the surface of these places. It is recommended that health authorities should pay more attention to cleaning and disinfecting surfaces around the pool, showers, dressing rooms etc, to prevent infectious disease transfer as a result of contact with contaminated swimming pool surfaces.

  5. UPDG: Utilities package for data analysis of Pooled DNA GWAS

    Directory of Open Access Journals (Sweden)

    Ho Daniel WH

    2012-01-01

    Full Text Available Abstract Background Despite being a well-established strategy for cost reduction in disease gene mapping, pooled DNA association study is much less popular than the individual DNA approach. This situation is especially true for pooled DNA genomewide association study (GWAS, for which very few computer resources have been developed for its data analysis. This motivates the development of UPDG (Utilities package for data analysis of Pooled DNA GWAS. Results UPDG represents a generalized framework for data analysis of pooled DNA GWAS with the integration of Unix/Linux shell operations, Perl programs and R scripts. With the input of raw intensity data from GWAS, UPDG performs the following tasks in a stepwise manner: raw data manipulation, correction for allelic preferential amplification, normalization, nested analysis of variance for genetic association testing, and summarization of analysis results. Detailed instructions, procedures and commands are provided in the comprehensive user manual describing the whole process from preliminary preparation of software installation to final outcome acquisition. An example dataset (input files and sample output files is also included in the package so that users can easily familiarize themselves with the data file formats, working procedures and expected output. Therefore, UPDG is especially useful for users with some computer knowledge, but without a sophisticated programming background. Conclusions UPDG provides a free, simple and platform-independent one-stop service to scientists working on pooled DNA GWAS data analysis, but with less advanced programming knowledge. It is our vision and mission to reduce the hindrance for performing data analysis of pooled DNA GWAS through our contribution of UPDG. More importantly, we hope to promote the popularity of pooled DNA GWAS, which is a very useful research strategy.

  6. A three-dimensional sharp interface model for self-consistent keyhole and weld pool dynamics in deep penetration laser welding

    International Nuclear Information System (INIS)

    Pang Shengyong; Chen Liliang; Zhou Jianxin; Yin Yajun; Chen Tao

    2011-01-01

    A three-dimensional sharp interface model is proposed to investigate the self-consistent keyhole and weld pool dynamics in deep penetration laser welding. The coupling of three-dimensional heat transfer, fluid flow and keyhole free surface evolutions in the welding process is simulated. It is theoretically confirmed that under certain low heat input welding conditions deep penetration laser welding with a collapsing free keyhole could be obtained and the flow directions near the keyhole wall are upwards and approximately parallel to the keyhole wall. However, significantly different weld pool dynamics in a welding process with an unstable keyhole are numerically found. Many flow patterns in the welding process with an unstable keyhole, verified by x-ray transmission experiments, were successfully simulated and analysed. Periodical keyhole collapsing and bubble formation processes are also successfully simulated and believed to be in good agreement with experiments. The mechanisms of keyhole instability are found to be closely associated with the behaviour of humps on the keyhole wall, and it is found that the welding speed and surface tension are closely related to the formation of humps on the keyhole wall. It is also shown that the weld pool dynamics in laser welding with an unstable keyhole are closely associated with the transient keyhole instability and therefore modelling keyhole and weld pool in a self-consistent way is significant to understand the physics of laser welding.

  7. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  8. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  9. Water inventory management in condenser pool of boiling water reactor

    International Nuclear Information System (INIS)

    Gluntz, D.M.

    1996-01-01

    An improved system for managing the water inventory in the condenser pool of a boiling water reactor has means for raising the level of the upper surface of the condenser pool water without adding water to the isolation pool. A tank filled with water is installed in a chamber of the condenser pool. The water-filled tank contains one or more holes or openings at its lowermost periphery and is connected via piping and a passive-type valve (e.g., squib valve) to a high-pressure gas-charged pneumatic tank of appropriate volume. The valve is normally closed, but can be opened at an appropriate time following a loss-of-coolant accident. When the valve opens, high-pressure gas inside the pneumatic tank is released to flow passively through the piping to pressurize the interior of the water-filled tank. In so doing, the initial water contents of the tank are expelled through the openings, causing the water level in the condenser pool to rise. This increases the volume of water available to be boiled off by heat conducted from the passive containment cooling heat exchangers. 4 figs

  10. Plasma non-esterified docosahexaenoic acid is the major pool supplying the brain.

    Science.gov (United States)

    Chen, Chuck T; Kitson, Alex P; Hopperton, Kathryn E; Domenichiello, Anthony F; Trépanier, Marc-Olivier; Lin, Lauren E; Ermini, Leonardo; Post, Martin; Thies, Frank; Bazinet, Richard P

    2015-10-29

    Despite being critical for normal brain function, the pools that supply docosahexaenoic acid (DHA) to the brain are not agreed upon. Using multiple kinetic models in free-living adult rats, we first demonstrate that DHA uptake from the plasma non-esterified fatty acid (NEFA) pool predicts brain uptake of DHA upon oral administration, which enters the plasma NEFA pool as well as multiple plasma esterified pools. The rate of DHA loss by the brain is similar to the uptake from the plasma NEFA pool. Furthermore, upon acute iv administration, although more radiolabeled lysophosphatidylcholine (LPC)-DHA enters the brain than NEFA-DHA, this is due to the longer plasma half-life and exposure to the brain. Direct comparison of the uptake rate of LPC-DHA and NEFA-DHA demonstrates that uptake of NEFA-DHA into the brain is 10-fold greater than LPC-DHA. In conclusion, plasma NEFA-DHA is the major plasma pool supplying the brain.

  11. Generation Expansion Planning in pool market: A hybrid modified game theory and improved genetic algorithm

    International Nuclear Information System (INIS)

    Shayanfar, H.A.; Lahiji, A. Saliminia; Aghaei, J.; Rabiee, A.

    2009-01-01

    Unlike the traditional policy, Generation Expansion Planning (GEP) problem in competitive framework is complicated. In the new policy, each Generation Company (GENCO) decides to invest in such a way that obtains as much profit as possible. This paper presents a new hybrid algorithm to determine GEP in a Pool market. The proposed algorithm is divided in two programming levels: master and slave. In the master level a Modified Game Theory (MGT) is proposed to evaluate the contrast of GENCOs by the Independent System Operator (ISO). In the slave level, an Improved Genetic Algorithm (IGA) method is used to find the best solution of each GENCO for decision-making of investment. The validity of the proposed method is examined in the case study including three GENCOs with multi-type of power plants. The results show that the presented method is both satisfactory and consistent with expectation. (author)

  12. Generation expansion planning in Pool market: A hybrid modified game theory and particle swarm optimization

    International Nuclear Information System (INIS)

    Moghddas-Tafreshi, S.M.; Shayanfar, H.A.; Saliminia Lahiji, A.; Rabiee, A.; Aghaei, J.

    2011-01-01

    Unlike the traditional policy, Generation Expansion Planning (GEP) problem in competitive framework is complicated. In the new policy, each GENeration COmpany (GENCO) decides to invest in such a way that obtains as much profit as possible. This paper presents a new hybrid algorithm to determine GEP in a Pool market. The proposed algorithm is divided in two programming levels: master and slave. In the master level a modified game theory (MGT) is proposed to evaluate the contrast of GENCOs by the Independent System Operator (ISO). In the slave level, a particle swarm optimization (PSO) method is used to find the best solution of each GENCO for decision-making of investment. The validity of the proposed method is examined in the case study including three GENCOs with multi-types of power plants. The results show that the presented method is both satisfactory and consistent with expectation.

  13. Titanium distribution in swimming pool water is dominated by dissolved species

    International Nuclear Information System (INIS)

    David Holbrook, R.; Motabar, Donna; Quiñones, Oscar; Stanford, Benjamin; Vanderford, Brett; Moss, Donna

    2013-01-01

    The increased use of titanium dioxide nanoparticles (nano-TiO 2 ) in consumer products such as sunscreen has raised concerns about their possible risk to human and environmental health. In this work, we report the occurrence, size fractionation and behavior of titanium (Ti) in a children's swimming pool. Size-fractionated samples were analyzed for Ti using ICP-MS. Total titanium concentrations ([Ti]) in the pool water ranged between 21 μg/L and 60 μg/L and increased throughout the 101-day sampling period while [Ti] in tap water remained relatively constant. The majority of [Ti] was found in the dissolved phase (<1 kDa), with only a minor fraction of total [Ti] being considered either particulate or microparticulate. Simple models suggest that evaporation may account for the observed variation in [Ti], while sunscreen may be a relevant source of particulate and microparticule Ti. Compared to diet, incidental ingestion of nano-Ti from swimming pool water is minimal. -- Highlights: •Total titanium concentrations in unfiltered swimming pool water ranged between 21 and 60 μg/L. •Evaporation of the swimming pool water is suspected of causing a temporal increase in [Ti]. •The vast majority of Ti is found in the dissolved phase (<1 kD). •Swimming pools are not a significant Ti source for human exposure via ingestion. -- In children's swimming pool water, the majority of titanium is found in the dissolved phase

  14. 76 FR 64085 - Post-2014 Resource Pool-Loveland Area Projects, Final Power Allocation

    Science.gov (United States)

    2011-10-17

    ... Resource Pool; Loveland Area Projects, General Eligibility Criteria. The resource pool for capacity and... transmission in Kansas. Final allocation of the Post-2014 Resource Pool; Loveland Area Projects, is contingent...

  15. Numerical simulation of pool boiling of a Lennard-Jones liquid

    KAUST Repository

    Inaoka, Hajime; Ito, Nobuyasu

    2013-01-01

    We performed a numerical simulation of pool boiling by a molecular dynamics model. In the simulation, a liquid composed of Lennard-Jones particles in a uniform gravitational field is heated by a heat source at the bottom of the system. The model successfully reproduces the change in regimes of boiling from nucleate boiling to film boiling with the increase of the heat source temperature. We present the pool boiling curve by the model, whose general behavior is consistent with those observed in experiments of pool boiling. © 2013 Elsevier B.V. All rights reserved.

  16. Numerical simulation of pool boiling of a Lennard-Jones liquid

    KAUST Repository

    Inaoka, Hajime

    2013-09-01

    We performed a numerical simulation of pool boiling by a molecular dynamics model. In the simulation, a liquid composed of Lennard-Jones particles in a uniform gravitational field is heated by a heat source at the bottom of the system. The model successfully reproduces the change in regimes of boiling from nucleate boiling to film boiling with the increase of the heat source temperature. We present the pool boiling curve by the model, whose general behavior is consistent with those observed in experiments of pool boiling. © 2013 Elsevier B.V. All rights reserved.

  17. A Mobile, Dynamic, and Privacy-Preserving Matching System for Car and Taxi Pools

    Directory of Open Access Journals (Sweden)

    Shin-Yan Chiou

    2014-01-01

    Full Text Available Recently, rates of vehicle ownership have risen globally, exacerbating problems including air pollution, lack of parking, and traffic congestion. While many solutions to these problems have been proposed, carpooling remains one of the most effective approaches. Recently, several carpooling platforms have been built on cloud computing systems, with originators posting online list of departure/arrival points and schedules from which participants can search for rides that match their needs. However, it can be difficult to make matches quickly and the systems are subject to privacy concerns in that they may disclose private information such as names, registration data, and departure/arrival schedules. This paper proposes a dynamic matching method for car/taxi pools for use in mobile devices via ad hoc Wi-Fi networks. The proposed method also preserves user privacy including names and departure/arrival schedules. Moreover, the system does not require the user to register any personal data, so such data cannot be leaked. The system was implemented on the Android mobile platform, allowing users to immediately and securely access the system via their smart phones.

  18. One component, volume heated, boiling pool thermohydraulics

    International Nuclear Information System (INIS)

    Bede, M.; Perret, C.; Pretrel, H.; Seiler, J.M.

    1993-01-01

    Prior work on boiling pools provided heat exchange correlations valid for bubbly flow with laminar or turbulent boundary layers. New experiments performed with water (SEBULON) and UO 2 (SCARABEE BF2) in a churn-turbulent flow configuration show unexpected heat flux distributions for which the maximum heat flux may be situated well below the pool surface. The origin of this behaviour is attributed to condensation effects, very unstable boundary layer flow and surface oscillation. A calculation model is discussed which permits to approach the experimental heat flux distribution with reasonable accuracy. (authors). 7 figs., 2 appendix., 14 refs

  19. Volume-heated boiling pool behavior and application to transition phase accident conditions

    International Nuclear Information System (INIS)

    Ginsberg, T.; Jones, O.C. Jr.; Chen, J.C.

    1978-01-01

    Observations of two-phase flow fields in volume-heated boiling pools are reported. Photographic observations, together with pool-average void fraction measurements are presented. Flow regime transition criterial derived from the measurements are discussed. The churn-turbulent flow regime was the dominant regime for superficial vapor velocity. Within this range of conditions, a churn-turbulent drift flux model provides a reasonable prediction of the pool-average void fraction data. The results of the experiment and analysis are extrapolated to transition phase conditions. It is shown that intense pool boil-up could occur where the pool-average void fraction would be greater than 0.6 for steel vaporization rates equivalent to power levels greater than one percent of nominal LMFBR power density. (author)

  20. AUS burnup module CHAR and the associated data pool

    International Nuclear Information System (INIS)

    Robinson, G.S.

    1975-12-01

    The CHAR module of the AUS reactor neutronics scheme solves the multiregion nuclide depletion equations using an analytic method. The module obtains cross section, flux and geometry data from AUS data pools, and uses the STATUS data pool which has been designed for the storage of nuclide compositions, spatial smearing factors and other miscellaneous information. (author)

  1. Inter-progenitor pool wiring: An evolutionarily conserved strategy that expands neural circuit diversity.

    Science.gov (United States)

    Suzuki, Takumi; Sato, Makoto

    2017-11-15

    Diversification of neuronal types is key to establishing functional variations in neural circuits. The first critical step to generate neuronal diversity is to organize the compartmental domains of developing brains into spatially distinct neural progenitor pools. Neural progenitors in each pool then generate a unique set of diverse neurons through specific spatiotemporal specification processes. In this review article, we focus on an additional mechanism, 'inter-progenitor pool wiring', that further expands the diversity of neural circuits. After diverse types of neurons are generated in one progenitor pool, a fraction of these neurons start migrating toward a remote brain region containing neurons that originate from another progenitor pool. Finally, neurons of different origins are intermingled and eventually form complex but precise neural circuits. The developing cerebral cortex of mammalian brains is one of the best examples of inter-progenitor pool wiring. However, Drosophila visual system development has revealed similar mechanisms in invertebrate brains, suggesting that inter-progenitor pool wiring is an evolutionarily conserved strategy that expands neural circuit diversity. Here, we will discuss how inter-progenitor pool wiring is accomplished in mammalian and fly brain systems. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Impacts of exotic mangroves and mangrove control on tide pool fish assemblages

    Science.gov (United States)

    Richard A. MacKenzie; Cailtin L. Kryss

    2013-01-01

    Fish were sampled from tide pools in Hawaii to determine how exotic mangroves Rhizophora mangle and the use of herbicides to chemically eradicate them are impacting tide pool fish assemblages. Ecological parameters were compared among mangrove-invaded, native vegetated, and non-vegetated tide pools before and after mangroves had been chemically...

  3. Experimental investigation on the weld pool formation process in plasma keyhole arc welding

    Science.gov (United States)

    Van Anh, Nguyen; Tashiro, Shinichi; Van Hanh, Bui; Tanaka, Manabu

    2018-01-01

    This paper seeks to clarify the weld pool formation process in plasma keyhole arc welding (PKAW). We adopted, for the first time, the measurement of the 3D convection inside the weld pool in PKAW by stereo synchronous imaging of tungsten tracer particles using two sets of x-ray transmission systems. The 2D convection on the weld pool surface was also measured using zirconia tracer particles. Through these measurements, the convection in a wide range of weld pools from the vicinity of the keyhole to the rear region was successfully visualized. In order to discuss the heat transport process in a weld pool, the 2D temperature distribution on the weld pool surface was also measured by two-color pyrometry. The results of the comprehensive experimental measurement indicate that the shear force due to plasma flow is found to be the dominant driving force in the weld pool formation process in PKAW. Thus, heat transport in a weld pool is considered to be governed by two large convective patterns near the keyhole: (1) eddy pairs on the surface (perpendicular to the torch axis), and (2) eddy pairs on the bulk of the weld pool (on the plane of the torch). They are formed with an equal velocity of approximately 0.35 m s-1 and are mainly driven by shear force. Furthermore, the flow velocity of the weld pool convection becomes considerably higher than that of other welding processes, such as TIG welding and GMA welding, due to larger plasma flow velocity.

  4. Observation of the bone mineral density of newly formed bone using rabbits. Compared with newly formed bone around implants and cortical bone

    International Nuclear Information System (INIS)

    Nakada, Hiroshi; Numata, Yasuko; Sakae, Toshiro; Tamaki, Hiroyuki; Kato, Takao

    2009-01-01

    There have been many studies reporting that newly formed bone around implants is spongy bone. However, although the morphology is reported as being like spongy bone, it is difficult to discriminate whether the bone quality of newly formed bone appears similar to osteoid or cortical bone; therefore, evaluation of bone quality is required. The aims of this study were to measure the bone mineral density (BMD) values of newly formed bone around implants after 4, 8, 16, 24 and 48 weeks, to represent these values on three-dimensional color mapping (3Dmap), and to evaluate the change in bone quality associated with newly formed bone around implants. The animal experimental protocol of this study was approved by the Ethics Committee for Animal Experiments of our University. This experiment used 20 surface treatment implants (Ti-6Al-4V alloy: 3.1 mm in diameter and 30.0 mm in length) by grit-blasting. They were embedded into surgically created flaws in femurs of 20 New Zealand white rabbits (16 weeks old, male). The rabbits were sacrificed with an ear intravenous overdose of pentobarbital sodium under general anesthesia each period, and the femurs were resected. We measured BMD of newly formed bone around implants and cortical bone using Micro-CT, and the BMD distribution map of 3Dmap (TRI/3D Bon BMD, Ratoc System Engineering). The BMD of cortical bone was 1,026.3±44.3 mg/cm 3 at 4 weeks, 1,023.8±40.9 mg/cm 3 at 8 weeks, 1,048.2±45.6 mg/cm 3 at 16 weeks, 1,067.2±60.2 mg/cm 3 at 24 weeks, and 1,069.3±50.7 mg/cm 3 at 48 weeks after implantation, showing a non-significant increase each period. The BMD of newly formed bone around implants was 296.8±25.6 mg/cm 3 at 4 weeks, 525.0±72.4 mg/cm 3 at 8 weeks, 691.2±26.0 mg/cm 3 at 16 weeks, 776.9±27.7 mg/cm 3 at 24 weeks, and 845.2±23.1 mg/cm 3 at 48 weeks after implantation, showing a significant increase after each period. It was revealed that the color scale of newly formed bone was Low level at 4 weeks, and then it

  5. A hierarchic sustainability dashboard to evaluate logistics pooling

    OpenAIRE

    Morana, Joëlle; Gonzalez-Feliu, Jesus

    2014-01-01

    Logistics pooling is now a major challenge in supply chain management, though it remains a little known activity in which the different actors involved use different approaches whose objectives are not always the same and with sometimes conflicting standpoints. This purpose of this article is to define, on the basis of a detailed analysis of the literature, a grid for interpreting and a dashboard for evaluating the sustainable performance of pooled delivery systems. Firstly, an analysis of th...

  6. Models for Pooled Time-Series Cross-Section Data

    Directory of Open Access Journals (Sweden)

    Lawrence E Raffalovich

    2015-07-01

    Full Text Available Several models are available for the analysis of pooled time-series cross-section (TSCS data, defined as “repeated observations on fixed units” (Beck and Katz 1995. In this paper, we run the following models: (1 a completely pooled model, (2 fixed effects models, and (3 multi-level/hierarchical linear models. To illustrate these models, we use a Generalized Least Squares (GLS estimator with cross-section weights and panel-corrected standard errors (with EViews 8 on the cross-national homicide trends data of forty countries from 1950 to 2005, which we source from published research (Messner et al. 2011. We describe and discuss the similarities and differences between the models, and what information each can contribute to help answer substantive research questions. We conclude with a discussion of how the models we present may help to mitigate validity threats inherent in pooled time-series cross-section data analysis.

  7. Crimpy enables discrimination of presynaptic and postsynaptic pools of a BMP at the Drosophila neuromuscular junction.

    Science.gov (United States)

    James, Rebecca E; Hoover, Kendall M; Bulgari, Dinara; McLaughlin, Colleen N; Wilson, Christopher G; Wharton, Kristi A; Levitan, Edwin S; Broihier, Heather T

    2014-12-08

    Distinct pools of the bone morphogenetic protein (BMP) Glass bottom boat (Gbb) control structure and function of the Drosophila neuromuscular junction. Specifically, motoneuron-derived Gbb regulates baseline neurotransmitter release, whereas muscle-derived Gbb regulates neuromuscular junction growth. Yet how cells differentiate between these ligand pools is not known. Here we present evidence that the neuronal Gbb-binding protein Crimpy (Cmpy) permits discrimination of pre- and postsynaptic ligand by serving sequential functions in Gbb signaling. Cmpy first delivers Gbb to dense core vesicles (DCVs) for activity-dependent release from presynaptic terminals. In the absence of Cmpy, Gbb is no longer associated with DCVs and is not released by activity. Electrophysiological analyses demonstrate that Cmpy promotes Gbb's proneurotransmission function. Surprisingly, the Cmpy ectodomain is itself released upon DCV exocytosis, arguing that Cmpy serves a second function in BMP signaling. In addition to trafficking Gbb to DCVs, we propose that Gbb/Cmpy corelease from presynaptic terminals defines a neuronal protransmission signal. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Evaluation of Decontamination Factor of Aerosol in Pool Scrubber according to Bubble Shape and Size

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyun Joung; Ha, Kwang Soon; Jang, Dong Soon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The scrubbing pool could play an important role in the wet type FCVS because a large amount of aerosol is captured in the water pool. The pool scrubbing phenomena have been modelled and embedded in several computer codes, such as SPARC (Suppression Pool Aerosol Removal Code), BUSCA (BUbble Scrubbing Algorithm) and SUPRA (Suppression Pool Retention Analysis). These codes aim at simulating the pool scrubbing process and estimating the decontamination factors (DFs) of the radioactive aerosol and iodine gas in the water pool, which is defined as the ratio of initial mass of the specific radioactive material to final massy after passing through the water pool. The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the pool. The developed code has been verified using the experimental results and parametric studies the decontamination factor according to bubble shape and size. To evaluate the decontamination factor more accurate whole pool scrubber phenomena, the code was improved to consider the variety shape and size of bubbles. The decontamination factor were largely evaluated in ellipsoid bubble rather than in sphere bubble. The pool scrubbing models will be enhanced to apply more various model such as aerosol condensation of hygroscopic. And, it is need to experiment to measure to bubble shape and size distribution in pool to improve bubble model.

  9. Heat and Fission Product Transport in a Molten U-Zr-O Pool With Crust

    International Nuclear Information System (INIS)

    Yun, J.I.; Suh, K.Y.; Kang, C.S.

    2002-01-01

    Heat transfer and fluid flow in a molten pool are influenced by internal volumetric heat generated from the radioactive decay of fission product species retained in the pool. The pool superheat is determined based on the overall energy balance that equates the heat production rate to the heat loss rate. Decay heat of fission products in the pool was estimated by product of the mass concentration and energy conversion factor of each fission product. For the calculation of heat generation rate in the pool, twenty-nine elements were chosen and classified by their chemical properties. The mass concentration of a fission product is obtained from released fraction and the tabular output of the ORIGEN 2 code. The initial core and pool inventories at each time can also be estimated using ORIGEN 2. The released fraction of each fission product is calculated based on the bubble dynamics and mass transport. Numerical analysis was performed for the TMI-2 accident. The pool is assumed to be a partially filled hemispherical geometry and the change of pool geometry during the numerical calculation was neglected. Results of the numerical calculation revealed that the peak temperature of the molten pool significantly decreased and most of the volatile fission products were released from the molten pool during the accident. (authors)

  10. The practical skills of newly qualified nurses.

    Science.gov (United States)

    Danbjørg, Dorthe Boe; Birkelund, Regner

    2011-02-01

    This paper reports the findings from a study of newly qualified nurses and which subjects the nurses regarded as the most important in order to be able to live up to the requirements of clinical practice, and how they experience their potential for developing practical and moral skills, after the decrease in practical training. A qualitative approach guided the research process and the analysis of the data. The data was collected by participant observation and qualitative interviews with four nurses as informants. The conclusions made in this study are based on the statements and the observations of the newly qualified nurses. Our findings are discussed in relation to the Aristotelian concept and other relevant literature. The main message is that the newly qualified nurses did not feel equipped when they finished their training. This could be interpreted as a direct consequence of the decrease in practical training. Our study also underlines that the way nursing theory is perceived and taught is problematic. The interviews revealed that the nurses think that nursing theories should be applied directly in practice. This misunderstanding is probably also applicable to the teachers of the theories. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Greenland Tidal Pools as Hot Spots for Ecosystem Metabolism and Calcification

    KAUST Repository

    Duarte, Carlos M.; Krause-Jensen, Dorte

    2018-01-01

    The hypothesis that Arctic tidal pools provide environmental conditions suitable for calcifiers during summer, thereby potentially providing refugia for calcifiers in an acidifying Arctic Ocean, was tested on the basis of measurements conducted during two midsummers (2014 and 2016) in tidal pools colonised by a community composed of macroalgae and calcifiers in Disko Bay, Greenland (69° N). The tidal pools exhibited steep diurnal variations in temperature from a minimum of about 6 °C during the night to a maximum of almost 18 °C in the afternoon, while the temperature of the surrounding shore water was much lower, typically in the range 3 to 8 °C. O2 concentrations in the tidal pools were elevated relative to those in the adjacent open waters, by up to 11 mg O2 L−1, and exhibited heavy super-saturation (up to > 240%) during daytime emersion, reflecting intense and sustained photosynthetic rates of the tidal macroalgae. The intense photosynthetic activity of the seaweeds resulted in the drawdown of pCO2 concentrations in the pools during the day to levels down to average (±SE) values of 66 ± 18 ppm, and a minimum recorded value of 14.7 ppm, corresponding to pH levels as high as 8.69 ± 0.08, as compared to CO2 levels of 256 ± 4 and pH levels of 8.14 ± 0.01 in the water flooding the pools during high tide. The corresponding Ωarag reached 5.04 ± 0.49 in the pools as compared to 1.55 ± 0.02 in the coastal waters flooding the pools. Net calcification averaged 9.6 ± 5.6 μmol C kg−1 h−1 and was strongly and positively correlated with calculated net ecosystem production rates, which averaged 27.5 ± 8.6 μmol C kg−1 h−1. Arctic tidal pools promote intense metabolism, creating conditions suitable for calcification during the Arctic summer, and can, therefore, provide refugia from ocean acidification to vulnerable calcifiers as extended periods of continuous light during summer are conducive to suitable conditions

  12. Greenland Tidal Pools as Hot Spots for Ecosystem Metabolism and Calcification

    KAUST Repository

    Duarte, Carlos M.

    2018-01-18

    The hypothesis that Arctic tidal pools provide environmental conditions suitable for calcifiers during summer, thereby potentially providing refugia for calcifiers in an acidifying Arctic Ocean, was tested on the basis of measurements conducted during two midsummers (2014 and 2016) in tidal pools colonised by a community composed of macroalgae and calcifiers in Disko Bay, Greenland (69° N). The tidal pools exhibited steep diurnal variations in temperature from a minimum of about 6 °C during the night to a maximum of almost 18 °C in the afternoon, while the temperature of the surrounding shore water was much lower, typically in the range 3 to 8 °C. O2 concentrations in the tidal pools were elevated relative to those in the adjacent open waters, by up to 11 mg O2 L−1, and exhibited heavy super-saturation (up to > 240%) during daytime emersion, reflecting intense and sustained photosynthetic rates of the tidal macroalgae. The intense photosynthetic activity of the seaweeds resulted in the drawdown of pCO2 concentrations in the pools during the day to levels down to average (±SE) values of 66 ± 18 ppm, and a minimum recorded value of 14.7 ppm, corresponding to pH levels as high as 8.69 ± 0.08, as compared to CO2 levels of 256 ± 4 and pH levels of 8.14 ± 0.01 in the water flooding the pools during high tide. The corresponding Ωarag reached 5.04 ± 0.49 in the pools as compared to 1.55 ± 0.02 in the coastal waters flooding the pools. Net calcification averaged 9.6 ± 5.6 μmol C kg−1 h−1 and was strongly and positively correlated with calculated net ecosystem production rates, which averaged 27.5 ± 8.6 μmol C kg−1 h−1. Arctic tidal pools promote intense metabolism, creating conditions suitable for calcification during the Arctic summer, and can, therefore, provide refugia from ocean acidification to vulnerable calcifiers as extended periods of continuous light during summer are conducive to suitable conditions

  13. Dynamics of inorganic nutrients in intertidal sediments: porewater, exchangeable and intracellular pools

    Directory of Open Access Journals (Sweden)

    Emilio eGarcia-Robledo

    2016-05-01

    Full Text Available The study of inorganic nutrients dynamics in shallow sediments usually focuses on two main pools: the porewater (PW nutrients and the exchangeable (EX ammonium and phosphate. Recently, it has been found that microphytobenthos (MPB and other microorganisms can accumulate large amounts of nutrients intracellularly (IC, highlighting the biogeochemical importance of this nutrient pool. Storing nutrients could support the growth of autotrophs when nutrients are not available, and could also provide alternative electron acceptors for dissimilatory processes such as nitrate reduction. Here, we studied the magnitude and relative importance of these three nutrient pools (PW, IC and EX and their relation to chlorophylls (used as a proxy for MPB abundance and organic matter (OM contents in an intertidal mudflat of Cadiz Bay (Spain. MPB was localized in the first 4 mm of the sediment and showed a clear seasonal pattern; highest chlorophylls content was found during autumn and lowest during spring-summer. The temporal and spatial distribution of nutrients pools and MPB were largely correlated. Ammonium was higher in the IC and EX fractions, representing on average 59 and 37% of the total ammonium pool, respectively. Similarly, phosphate in the IC and EX fractions accounted on average for 40 and 31% of the total phosphate pool, respectively. Nitrate in the PW was low, suggesting low nitrification activity and rapid consumption. Nitrate accumulated in the IC pool during periods of moderate MPB abundance, being up to 66% of the total nitrate pool, whereas it decreased when chlorophyll concentration peaked likely due to a high nitrogen demand. EX-Nitrate accounted for the largest fraction of total sediment nitrate, 66% on average. The distribution of EX-Nitrate was significantly correlated with chlorophyll and OM, which probably indicates a relation of this pool to an increased availability of sites for ionic adsorption. This EX-Nitrate pool could represent an

  14. 7 CFR 1126.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ... excluded from the supply plant's shipments in computing the plant's shipping percentage. (d) A plant... part, or the plant has automatic pooling status under the other Federal order; and (7) That portion of...

  15. Equilibrium blood pool scanning in the evaluation of hemophilic arthropathy

    International Nuclear Information System (INIS)

    Spies, S.; Green, D.; Rana, N.A.; Milgram, J.W.; Mintzer, R.

    1978-01-01

    Arthropathy was evaluated in six patients with severe hemophilia (factor VIII<1%) using the technique of blood pool scanning. Employing an in vivo method for erythrocyte labelling with technetium-99m, a dynamic perfusion sequence was obtained using a scintillation camera over the joint(s) to be examined. Subsequently, equilibrium blood pool images of the joints were obtained to determine regional blood volume. In young patients with repeated episodes of acute hemarthrosis, increased vascularity and increased blood pool in the affected joints were demonstrated. In older patients with fixed, contracted joints and degenerative arthropathy, vascularity and regional blood volume were not abnormal. Blood pool scanning is a safe, non-invasive technique that augments the clinical and radiographic examination of the joints. The method is helpful in distinguishing acute joint bleeding from chronic synovitis and arthritis, and may prove useful in selecting patients for synovectomy. (author)

  16. Newly graduated nurses' use of knowledge sources: a meta-ethnography.

    Science.gov (United States)

    Voldbjerg, Siri Lygum; Grønkjaer, Mette; Sørensen, Erik Elgaard; Hall, Elisabeth O C

    2016-08-01

    To advance evidence on newly graduated nurses' use of knowledge sources. Clinical decisions need to be evidence-based and understanding the knowledge sources that newly graduated nurses use will inform both education and practice. Qualitative studies on newly graduated nurses' use of knowledge sources are increasing though generated from scattered healthcare contexts. Therefore, a metasynthesis of qualitative research on what knowledge sources new graduates use in decision-making was conducted. Meta-ethnography. Nineteen reports, representing 17 studies, published from 2000-2014 were identified from iterative searches in relevant databases from May 2013-May 2014. Included reports were appraised for quality and Noblit and Hare's meta-ethnography guided the interpretation and synthesis of data. Newly graduated nurses' use of knowledge sources during their first 2-year postgraduation were interpreted in the main theme 'self and others as knowledge sources,' with two subthemes 'doing and following' and 'knowing and doing,' each with several elucidating categories. The metasynthesis revealed a line of argument among the report findings underscoring progression in knowledge use and perception of competence and confidence among newly graduated nurses. The transition phase, feeling of confidence and ability to use critical thinking and reflection, has a great impact on knowledge sources incorporated in clinical decisions. The synthesis accentuates that for use of newly graduated nurses' qualifications and skills in evidence-based practice, clinical practice needs to provide a supportive environment which nurtures critical thinking and questions and articulates use of multiple knowledge sources. © 2016 John Wiley & Sons Ltd.

  17. Clean-up system for pool water in pressure suppression chamber and operation method therefor

    Energy Technology Data Exchange (ETDEWEB)

    Hirabayashi, Kentaro; Kinoshita, Shoichiro

    1996-09-17

    Pool water in a pressure suppression chamber of a BWR type reactor is sucked by a pump of an after-heat removing system. The pool water pressurized here is sent to the pressure suppression chamber by way of a heat exchanger and a test line backwarding pipeline to stir the pool water in the pressure suppression chamber. Further, the pool water pressurized by the pump is sent to the pressure suppression chamber by way of a filtration desalting device and an exit pipe to purify the pool water. Upon cleaning of pipelines before the start of a periodical test, the pool water sucked by the pump is sent to the filtration desalting device and recovered to the pressure suppression chamber. This can reduce the amount of impurities carried to the suppression chamber. After the cleaning of the pipelines, pool water is passed through the test line backwarding pipeline, so that the pool water can be stirred at the same time. (I.N.)

  18. Pump/heat exchanger assembly for pool-type reactor

    International Nuclear Information System (INIS)

    Nathenson, R.D.; Slepian, R.M.

    1987-01-01

    A heat exchanger and pump assembly comprising a heat exchanger including a housing for defining an annularly shaped cavity and supporting therein a plurality of heat transfer tubes. A pump is disposed beneath the heat exchanger and is comprised of a plurality of flow couplers disposed in a circular array. Each flow coupler is comprised of a pump duct for receiving a first electrically conductive fluid, i.e. the primary liquid metal, from a pool thereof, and a generator duct for receiving a second electrically conductive fluid, i.e. the intermediate liquid metal. The primary liquid metal is introduced from the reactor pool into the top, inlet ends of the tubes, flowing downward therethrough to be discharged from the tubes' bottom ends directly into the reactor pool. The primary liquid metal is variously introduced into the pump ducts directly from the reactor pool, either from the bottom or top end of the flow coupler. The intermediate fluid introduced into the generator ducts via the inlet duct and inlet plenum and after leaving the generator ducts passes through the annular cavity of the exchanger to cool the primary liquid in the tubes. The annular magnetic field of the pump is produced by a circular array of electromagnets having hollow windings cooled by a flow of the intermediate metal. (author)

  19. Convective cooling in a pool-type research reactor

    Science.gov (United States)

    Sipaun, Susan; Usman, Shoaib

    2016-01-01

    A reactor produces heat arising from fission reactions in the nuclear core. In the Missouri University of Science and Technology research reactor (MSTR), this heat is removed by natural convection where the coolant/moderator is demineralised water. Heat energy is transferred from the core into the coolant, and the heated water eventually evaporates from the open pool surface. A secondary cooling system was installed to actively remove excess heat arising from prolonged reactor operations. The nuclear core consists of uranium silicide aluminium dispersion fuel (U3Si2Al) in the form of rectangular plates. Gaps between the plates allow coolant to pass through and carry away heat. A study was carried out to map out heat flow as well as to predict the system's performance via STAR-CCM+ simulation. The core was approximated as porous media with porosity of 0.7027. The reactor is rated 200kW and total heat density is approximately 1.07+E7 Wm-3. An MSTR model consisting of 20% of MSTR's nuclear core in a third of the reactor pool was developed. At 35% pump capacity, the simulation results for the MSTR model showed that water is drawn out of the pool at a rate 1.28 kg s-1 from the 4" pipe, and predicted pool surface temperature not exceeding 30°C.

  20. Vibro-acoustic performance of newly designed tram track structures

    Science.gov (United States)

    Haladin, Ivo; Lakušić, Stjepan; Ahac, Maja

    2017-09-01

    Rail vehicles in interaction with a railway structure induce vibrations that are propagating to surrounding structures and cause noise disturbance in the surrounding areas. Since tram tracks in urban areas often share the running surface with road vehicles one of top priorities is to achieve low maintenance and long lasting structure. Research conducted in scope of this paper gives an overview of newly designed tram track structures designated for use on Zagreb tram network and their performance in terms of noise and vibration mitigation. Research has been conducted on a 150 m long test section consisted of three tram track types: standard tram track structure commonly used on tram lines in Zagreb, optimized tram structure for better noise and vibration mitigation and a slab track with double sleepers embedded in a concrete slab, which presents an entirely new approach of tram track construction in Zagreb. Track has been instrumented with acceleration sensors, strain gauges and revision shafts for inspection. Relative deformations give an insight into track structure dynamic load distribution through the exploitation period. Further the paper describes vibro-acoustic measurements conducted at the test site. To evaluate the track performance from the vibro-acoustical standpoint, detailed analysis of track decay rate has been analysed. Opposed to measurement technique using impact hammer for track decay rate measurements, newly developed measuring technique using vehicle pass by vibrations as a source of excitation has been proposed and analysed. Paper gives overview of the method, it’s benefits compared to standard method of track decay rate measurements and method evaluation based on noise measurements of the vehicle pass by.

  1. Proposing the lymphatic target volume for elective radiation therapy for pancreatic cancer: a pooled analysis of clinical evidence

    Directory of Open Access Journals (Sweden)

    Lu Jiade J

    2010-04-01

    Full Text Available Abstract Background Radiation therapy is an important cancer treatment modality in both adjuvant and definitive setting, however, the use of radiation therapy for elective treatment of regional lymph nodes is controversial for pancreatic cancer. No consensus on proper selection and delineation of subclinical lymph nodal areas in adjuvant or definitive radiation therapy has been suggested either conclusively or proposed for further investigation. This analysis aims to study the pattern of lymph node metastasis through a pooled analysis of published results after radical tumor and lymph nodal resection with histological study in pancreatic cancer. Methods Literature search using electronic databases including MEDLINE, EMBASE, and CANCERLIT from January 1970 to June 2009 was performed, supplemented by review of references. Eighteen original researches and a total of 5954 pancreatic cancer patients underwent radical surgical resection were included in this analysis. The probability of metastasis in regional lymph nodal stations (using Japan Pancreas Society [JPS] Classification was calculated and analyzed based on the location and other characteristics of the primary disease. Results Commonly involved nodal regions in patients with pancreatic head tumor include lymph nodes around the common hepatic artery (Group 8, 9.79%, posterior pancreaticoduodenal lymph nodes (Group 13, 32.31%, lymph nodes around the superior mesenteric artery (Group 14, 15.85%, paraaortic lymph nodes (Group 16, 10.92%, and anterior pancreaticoduodenal lymph nodes (Group 17, 19.78%; The probability of metastasis in other lymph nodal regions were Commonly involved nodal regions in patients with pancreatic body/tail tumor include lymph nodes around the common hepatic artery (Group 8, 15.07%, lymph nodes around the celiac trunk (Group 9, 9.59%, lymph nodes along the splenic artery (Group 11, 35.62%, lymph nodes around the superior mesenteric artery (Group 14, 9.59%, paraaortic

  2. Validation analysis of pool fire experiment (Run-F7) using SPHINCS code

    International Nuclear Information System (INIS)

    Yamaguchi, Akira; Tajima, Yuji

    1998-04-01

    SPHINCS (Sodium Fire Phenomenology IN multi-Cell System) code has been developed for the safety analysis of sodium fire accident in a Fast Breeder Reactor. The main features of the SPHINCS code with respect to the sodium pool fire phenomena are multi-dimensional modeling of the thermal behavior in sodium pool and steel liner, modeling of the extension of sodium pool area based on the sodium mass conservation, and equilibrium model for the chemical reaction of pool fire on the flame sheet at the surface of sodium pool during. Therefore, the SPHINCS code is capable of temperature evaluation of the steel liner in detail during the small and/or medium scale sodium leakage accidents. In this study, Run-F7 experiment in which the sodium leakage rate is 11.8 kg/hour has been analyzed. In the experiment the diameter of the sodium pool is approximately 60 cm and the maximum steel liner temperature was 616 degree C. The analytical results tell us the agreement between the SPHINCS analysis and the experiment is excellent with respect to the time history and spatial distribution of the liner temperature, sodium pool extension behavior, as well as atmosphere gas temperature. It is concluded that the pool fire modeling of the SPHINCS code has been validated for this experiment. The SPHINCS code is currently applicable to the sodium pool fire phenomena and the temperature evaluation of the steel liner. The experiment series are continued to check some parameters, i.e., sodium leakage rate and the height of sodium leakage. Thus, the author will analyze the subsequent experiments to check the influence of the parameters and applies SPHINCS to the sodium fire consequence analysis of fast reactor. (author)

  3. Analysis of radiation shields of BNPP spent fuel pool

    International Nuclear Information System (INIS)

    Ayoobian, N.; Hadad, K.; Nematollahi, M. R.

    2007-01-01

    Radioactive protection is one of the most important subjects in nuclear power plants safety. Analysis of BNPP spent fuel pool shielding , as a main source of energetic γ-rays was the main goal of this project. Firstly, we simulated the reactor core using WIMSD-4 neutronic code and the amount of fission product in the fuel assembly (FA) was calculated during the reactor operation. Then, by obtaining the results from the previous calculation and by using MCNP4C nuclear code , the intensity of γ-rays was obtained in layers of spent fuel pool shields. The results have shown that no significant γ-rays passed through these shields. Finally, an accident and resulting exposure dose above the pool was analyzed

  4. Analyzing data distribution on disk pools for dCache

    Energy Technology Data Exchange (ETDEWEB)

    Halstenberg, S; Jung, C; Ressmann, D [Forschungszentrum Karlsruhe, Steinbuch Centre for Computing, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2010-04-01

    Most Tier-1 centers of LHC Computing Grid are using dCache as their storage system. dCache uses a cost model incorporating CPU and space costs for the distribution of data on its disk pools. Storage resources at Tier-1 centers are usually upgraded once or twice a year according to given milestones. One of the effects of this procedure is the accumulation of heterogeneous hardware resources. For a dCache system, a heterogeneous set of disk pools complicates the process of weighting CPU and space costs for an efficient distribution of data. In order to evaluate the data distribution on the disk pools, the distribution is simulated in Java. The results are discussed and suggestions for improving the weight scheme are given.

  5. Removal of volatile iodine from gas bubbles rising in water pools: review and assessment of pool scrubbing codes

    Energy Technology Data Exchange (ETDEWEB)

    Polo, J; Herranz, L E; Peyres, V; Escudero, M [CIEMAT, Nuclear Technology Institute, Madrid (Spain)

    1996-12-01

    During a hypothetical nuclear reactor accident with core damage the fission products released from the degrading fuel bundles often pass through aqueous beds before entering the containment, mitigating in part the source term. Several computer codes have been developed for predicting the fission product and aerosols removal in pool scrubbing scenarios. In addition to particle removal, these codes simulate the retention of some volatile iodine compounds. In this work a review of volatile iodine removal models included in SPARC and BUSCA codes is presented. Besides, the results and discussions of a validation of both codes against the available experimental data are summarized. SPARC and BUSCA codes model the diffusion of iodine toward the bubble interface by using the film penetration theory, which assumes a double layer gas-liquid at the interface. However, there are some differences between the two models, mainly related to the boundary conditions in the aqueous volume for the diffusion of molecular iodine. In SPARC, a set of fast reactions in the liquid phase control both the molecular iodine concentration in the pool and the partition coefficient of iodine at the interface. Thus, the aqueous chemistry plays an important role in the boundary conditions for the diffusion process. On the contrary, the BUSCA model has no chemical considerations at all, and assumes a null iodine concentration in the water bulk. Several sensitivity studies have been made in order to weight the effect of these differences. The variables examined in these studies were the pool temperature and the incoming iodine concentration in the pool. Additionally, sensitivity studies focused on the steam mass fraction of the injected gas were performed to study the effect of the different approach of both models for the condensation process. The results showed a different sensitivity of SPARC and BUSCA to the incoming concentration. (author) 5 tabs., 26 refs.

  6. 7 CFR 1001.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ... excluded from the supply plant's shipments in computing the percentages in paragraphs (c)(1) and (2) of... plant has automatic pooling status under the other Federal order. [64 FR 47954, Sept. 1, 1999, as...

  7. Disinfection by-product formation of UV treated swimming pool water

    DEFF Research Database (Denmark)

    Spiliotopoulou, Aikaterini; Hansen, Kamilla Marie Speht; Andersen, Henrik Rasmus

    2015-01-01

    Water samples from 3 indoor swimming pool facilities were tested to evaluate UV-induced effects on swimming pool water chemistry. Concentration change of several DBPs was investigated in experiments including medium pressure UV treatment with and without chlorine and post-UV chlorination. Post-UV...

  8. Fuel assembly storage pool

    International Nuclear Information System (INIS)

    Hiranuma, Hiroshi.

    1976-01-01

    Object: To remove limitation of the number of storage of fuel assemblies to increase the number of storage thereof so as to relatively reduce the water depth required for shielding radioactive rays. Structure: Fuel assembly storage rack containers for receiving a plurality of spent fuel assembly racks are stacked in multi-layer fashion within a storage pool filled with water for shielding radioactive rays and removing heat. (Furukawa, Y.)

  9. Development of INSPCT-S for inspection of spent fuel pool

    Energy Technology Data Exchange (ETDEWEB)

    Walters, W.; Haghighat, A. [Nuclear Engineering Program, Mechanical Engineering Dept., Virginia Tech., Blacksburg, VA 24061 (United States); Sitaraman, S.; Ham, Y. [Lawrence Livermore National Laboratory, 7000 East Ave., Livermore, CA 94550 (United States)

    2011-07-01

    In this paper, we discuss an accurate and fast software tool (INSPCT-S, Inspection of Nuclear Spent fuel-Pool Calculation Tool, version Spreadsheet) developed for calculation of the response of fission chambers placed in a spent fuel pool, such as Atucha-I. INSPCT-S is developed for identification of suspicious regions of the pool that may have missing or substitute assemblies. INSPCT-S uses a hybrid algorithm based on the adjoint function methodology. The neutron source is comprised of spontaneous fission, ({alpha}, n) interactions, and subcritical multiplication. The former is evaluated using the ORIGEN-ARP code, and the latter is obtained with the fission matrix (FM) formulation. The FM coefficients are determined using the MCNP Monte Carlo code, and the importance function is determined using the PENTRAN 3-D parallel Sn code. Three databases for the neutron source, FM elements, and adjoint flux are prepared as functions of different parameters including burnup, cooling time, enrichment, and pool lattice size. INSPCT-S uses the aforementioned databases and systems of equations to calculate detector responses, which are subsequently compared with normalized experimental data. If this comparison is not satisfied, INSPCT-S utilizes color coding to identify the suspicious regions of a spent fuel pool. (authors)

  10. Mathematical modelling and simulation of the thermal performance of a solar heated indoor swimming pool

    OpenAIRE

    Mančić Marko V.; Živković Dragoljub S.; Milosavljević Peđa M.; Todorović Milena N.

    2014-01-01

    Buildings with indoor swimming pools have a large energy footprint. The source of major energy loss is the swimming pool hall where air humidity is increased by evaporation from the pool water surface. This increases energy consumption for heating and ventilation of the pool hall, fresh water supply loss and heat demand for pool water heating. In this paper, a mathematical model of the swimming pool was made to assess energy demands of an indoor swimming po...

  11. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  12. Spent fuel pool thermal-hydraulic analysis using RELAP5-3D

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, M. C.; Fernandes, G.H.N.; Costa, A.L.; Pereira, F.; Pereira, C., E-mail: marc5663@gmail.com, E-mail: ghnfernandes@pq.cnpq.br, E-mail: claubia@nuclear.ufmg.br, E-mail: antonella@nuclear.ufmg.br [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    In order to analyze the thermo-hydraulic behavior of spent fuel pools, and taking as reference a hypothetic PWR nuclear plant, a model of RELAP-3D for a spent fuel pool has been built. This model has been used to simulate a loss of coolant in SPF. This study focuses on the loss of coolant flow accident in spent fuel storage pool which is modelled by using RELAP5-3D code to observe the coolant level reduction and fuel uncovery because of decay heat generation of the spent fuel in the pool. The results have been compared with the available data. The developed model demonstrated that the RELAP5-3D is capable of reproduce the thermal behavior of SPF in a transient scenario. (author)

  13. Condensation of vapor bubble in subcooled pool

    Science.gov (United States)

    Horiuchi, K.; Koiwa, Y.; Kaneko, T.; Ueno, I.

    2017-02-01

    We focus on condensation process of vapor bubble exposed to a pooled liquid of subcooled conditions. Two different geometries are employed in the present research; one is the evaporation on the heated surface, that is, subcooled pool boiling, and the other the injection of vapor into the subcooled pool. The test fluid is water, and all series of the experiments are conducted under the atmospheric pressure condition. The degree of subcooling is ranged from 10 to 40 K. Through the boiling experiment, unique phenomenon known as microbubble emission boiling (MEB) is introduced; this phenomenon realizes heat flux about 10 times higher than the critical heat flux. Condensation of the vapor bubble is the key phenomenon to supply ambient cold liquid to the heated surface. In order to understand the condensing process in the MEB, we prepare vapor in the vapor generator instead of the evaporation on the heated surface, and inject the vapor to expose the vapor bubble to the subcooled liquid. Special attention is paid to the dynamics of the vapor bubble detected by the high-speed video camera, and on the enhancement of the heat transfer due to the variation of interface area driven by the condensation.

  14. The impact of organisational culture on the adaptation of newly ...

    African Journals Online (AJOL)

    Usually newly employed nurses find adjusting to a work setting a challenging experience. Their successful adaptation to their work situation is greatly influenced by the socialisation process inherent in the organisational culture. The newly employed nurse often finds that the norms are unclear, confusing and restrictive.

  15. Proposing a Technical Solution for Restoring Longitudinal Connectivity in the Brădeni/Retiş Accumulation Area on Hârtibaciu River

    Directory of Open Access Journals (Sweden)

    Voicu Răzvan

    2016-04-01

    Full Text Available The fish fauna of the Hârtibaciu River has experienced a disrupted connectivity due to the hydrotechnical works and the Brădeni/Retiş Dam located across the Hârtibaciu watercourse being one of this significant obstacles. The newly proposed constructed wetlands can improve the habitat quality for the fish species of conservative interest sampled in the Brădeni/Retiş Dam proximity Rhodeus amarus, and can increase the individuals’ number of this population. Also can benefit the local populations of Phoxinus phoxinus and Gobio obtusirostris. Using gravitational force and also the underground layout, a proposed technical solution gives maximum safety regarding the water supply for the newly proposed to be created wetlands.

  16. Spent nuclear fuel storage pool thermal-hydraulic analysis

    International Nuclear Information System (INIS)

    Gay, R.R.

    1984-01-01

    Storage methods and requirements for spent nuclear fuel at U.S. commercial light water reactors are reviewed in Section 1. Methods of increasing current at-reactor storage capabilities are also outlined. In Section 2 the development of analytical methods for the thermal-hydraulic analysis of spent fuel pools is chronicled, leading up to a discussion of the GFLOW code which is described in Section 3. In Section 4 the verification of GFLOW by comparisons of the code's predictions to experimental data taken inside the fuel storage pool at the Maine Yankee nuclear power plant is presented. The predictions of GFLOW using 72, 224, and 1584 node models of the storage pool are compared to each other and to the experimental data. An example of thermal licensing analysis for Maine Yankee using the GFLOW code is given in Section 5. The GFLOW licensing analysis is compared to previous licensing analysis performed by Yankee Atomic using the RELAP-4 computer code

  17. 13 CFR 120.1703 - Qualifications to be a Pool Originator.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Qualifications to be a Pool Originator. 120.1703 Section 120.1703 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools...

  18. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  19. Molten pool characterization of laser lap welded copper and aluminum

    Science.gov (United States)

    Xue, Zhiqing; Hu, Shengsun; Zuo, Di; Cai, Wayne; Lee, Dongkyun; Elijah, Kannatey-Asibu, Jr.

    2013-12-01

    A 3D finite volume simulation model for laser welding of a Cu-Al lap joint was developed using ANSYS FLUENT to predict the weld pool temperature distribution, velocity field, geometry, alloying element distribution and transition layer thickness—all key attributes and performance characteristics for a laser-welded joint. Melting and solidification of the weld pool was simulated with an enthalpy-porosity formulation. Laser welding experiments and metallographic examination by SEM and EDX were performed to investigate the weld pool features and validate the simulated results. A bowl-shaped temperature field and molten pool, and a unique maximum fusion zone width were observed near the Cu-Al interface. Both the numerical simulation and experimental results indicate an arch-shaped intermediate layer of Cu and Al, and a gradual transition of Cu concentration from the aluminum plate to the copper plate with high composition gradient. For the conditions used, welding with Cu on top was found to result in a better weld joint.

  20. Molten pool characterization of laser lap welded copper and aluminum

    International Nuclear Information System (INIS)

    Xue, Zhiqing; Hu, Shengsun; Zuo, Di; Cai, Wayne; Lee, Dongkyun; Elijah, Kannatey-Asibu Jr

    2013-01-01

    A 3D finite volume simulation model for laser welding of a Cu–Al lap joint was developed using ANSYS FLUENT to predict the weld pool temperature distribution, velocity field, geometry, alloying element distribution and transition layer thickness—all key attributes and performance characteristics for a laser-welded joint. Melting and solidification of the weld pool was simulated with an enthalpy-porosity formulation. Laser welding experiments and metallographic examination by SEM and EDX were performed to investigate the weld pool features and validate the simulated results. A bowl-shaped temperature field and molten pool, and a unique maximum fusion zone width were observed near the Cu–Al interface. Both the numerical simulation and experimental results indicate an arch-shaped intermediate layer of Cu and Al, and a gradual transition of Cu concentration from the aluminum plate to the copper plate with high composition gradient. For the conditions used, welding with Cu on top was found to result in a better weld joint. (paper)

  1. Cells Lacking mtDNA Display Increased dNTP Pools upon DNA Damage

    DEFF Research Database (Denmark)

    Skovgaard, Tine; Rasmussen, Lene Juel; Munch-Petersen, Birgitte

    Imbalanced dNTP pools are highly mutagenic due to a deleterious effect on DNA polymerase fidelity. Mitochondrial DNA defects, including mutations and deletions, are commonly found in a wide variety of different cancer types. In order to further study the interconnection between dNTP pools...... and mitochondrial function we have examined the effect of DNA damage on dNTP pools in cells deficient of mtDNA. We show that DNA damage induced by UV irradiation, in a dose corresponding to LD50, induces an S phase delay in different human osteosarcoma cell lines. The UV pulse also has a destabilizing effect...... shows that normal mitochondrial function is prerequisite for retaining stable dNTP pools upon DNA damage. Therefore it is likely that mitochondrial deficiency defects may cause an increase in DNA mutations by disrupting dNTP pool balance....

  2. Convective Cold Pool Structure and Boundary Layer Recovery in DYNAMO

    Science.gov (United States)

    Savarin, A.; Chen, S. S.; Kerns, B. W.; Lee, C.; Jorgensen, D. P.

    2012-12-01

    One of the key factors controlling convective cloud systems in the Madden-Julian Oscillation (MJO) over the tropical Indian Ocean is the property of the atmospheric boundary layer. Convective downdrafts and precipitation from the cloud systems produce cold pools in the boundary layer, which can inhibit subsequent development of convection. The recovery time is the time it takes for the boundary layer to return to pre convective conditions. It may affect the variability of the convection on various time scales during the initiation of MJO. This study examines the convective cold pool structure and boundary layer recovery using the NOAA WP-3D aircraft observations, include the flight-level, Doppler radar, and GPS dropsonde data, collected during the Dynamics of MJO (DYNAMO) field campaign from November-December 2011. The depth and strength of convective cold pools are defined by the negative buoyancy, which can be computed from the dropsonde data. Convective downdraft can be affected by environmental water vapor due to entrainment. Mid-level dry air observed during the convectively suppressed phase of MJO seems to enhance convective downdraft, making the cold pools stronger and deeper. Recovery of the cold pools in the boundary layer is determined by the strength and depth of the cold pools and also the air-sea heat and moisture fluxes. Given that the water vapor and surface winds are distinct for the convectively active and suppressed phases of MJO over the Indian Ocean, the aircraft data are stratified by the two different large-scale regimes of MJO. Preliminary results show that the strength and depth of the cold pools are inversely correlated with the surrounding mid-level moisture. During the convectively suppressed phase, the recovery time is ~5-20 hours in relative weak wind condition with small air-sea fluxes. The recovery time is generally less than 6 hours during the active phase of MJO with moist mid-levels and stronger surface wind and air-sea fluxes.

  3. Laboratory model study of newly deposited dredger fills using improved multiple-vacuum preloading technique

    Directory of Open Access Journals (Sweden)

    Jingjin Liu

    2017-10-01

    Full Text Available Problems continue to be encountered concerning the traditional vacuum preloading method in field during the treatment of newly deposited dredger fills. In this paper, an improved multiple-vacuum preloading method was developed to consolidate newly dredger fills that are hydraulically placed in seawater for land reclamation in Lingang Industrial Zone of Tianjin City, China. With this multiple-vacuum preloading method, the newly deposited dredger fills could be treated effectively by adopting a novel moisture separator and a rapid improvement technique without sand cushion. A series of model tests was conducted in the laboratory for comparing the results from the multiple-vacuum preloading method and the traditional one. Ten piezometers and settlement plates were installed to measure the variations in excess pore water pressures and moisture content, and vane shear strength was measured at different positions. The testing results indicate that water discharge–time curves obtained by the traditional vacuum preloading method can be divided into three phases: rapid growth phase, slow growth phase, and steady phase. According to the process of fluid flow concentrated along tiny ripples and building of larger channels inside soils during the whole vacuum loading process, the fluctuations of pore water pressure during each loading step are divided into three phases: steady phase, rapid dissipation phase, and slow dissipation phase. An optimal loading pattern which could have a best treatment effect was proposed for calculating the water discharge and pore water pressure of soil using the improved multiple-vacuum preloading method. For the newly deposited dredger fills at Lingang Industrial Zone of Tianjin City, the best loading step was 20 kPa and the loading of 40–50 kPa produced the highest drainage consolidation. The measured moisture content and vane shear strength were discussed in terms of the effect of reinforcement, both of which indicate

  4. A swimming pool array for ultra high energy showers

    Science.gov (United States)

    Yodh, Gaurang B.; Shoup, Anthony; Barwick, Steve; Goodman, Jordan A.

    1992-11-01

    A very preliminary design concept for an array using water Cherenkov counters, built out of commercially available backyard swimming pools, to sample the electromagnetic and muonic components of ultra high energy showers at large lateral distances is presented. The expected performance of the pools is estimated using the observed lateral distributions by scintillator and water Cherenkov arrays at energies above 1019 eV and simulations.

  5. Impact and quantification of the sources of error in DNA pooling designs.

    Science.gov (United States)

    Jawaid, A; Sham, P

    2009-01-01

    The analysis of genome wide variation offers the possibility of unravelling the genes involved in the pathogenesis of disease. Genome wide association studies are also particularly useful for identifying and validating targets for therapeutic intervention as well as for detecting markers for drug efficacy and side effects. The cost of such large-scale genetic association studies may be reduced substantially by the analysis of pooled DNA from multiple individuals. However, experimental errors inherent in pooling studies lead to a potential increase in the false positive rate and a loss in power compared to individual genotyping. Here we quantify various sources of experimental error using empirical data from typical pooling experiments and corresponding individual genotyping counts using two statistical methods. We provide analytical formulas for calculating these different errors in the absence of complete information, such as replicate pool formation, and for adjusting for the errors in the statistical analysis. We demonstrate that DNA pooling has the potential of estimating allele frequencies accurately, and adjusting the pooled allele frequency estimates for differential allelic amplification considerably improves accuracy. Estimates of the components of error show that differential allelic amplification is the most important contributor to the error variance in absolute allele frequency estimation, followed by allele frequency measurement and pool formation errors. Our results emphasise the importance of minimising experimental errors and obtaining correct error estimates in genetic association studies.

  6. Spent fuel and fuel pool component integrity. Annual report, FY 1979

    International Nuclear Information System (INIS)

    Johnson, A.B. Jr.; Bailey, W.J.; Schreiber, R.E.; Kustas, F.M.

    1980-05-01

    International meetings under the BEFAST program and under INFCE Working Group No. 6 during 1978 and 1979 continue to indicate that no cases of fuel cladding degradation have developed on pool-stored fuel from water reactors. A section from a spent fuel rack stand, exposed for 1.5 y in the Yankee Rowe (PWR) pool had 0.001- to 0.003-in.-deep (25- to 75-μm) intergranular corrosion in weld heat-affected zones but no evidence of stress corrosion cracking. A section of a 304 stainless steel spent fuel storage rack exposed 6.67 y in the Point Beach reactor (PWR) spent fuel pool showed no significant corrosion. A section of 304 stainless steel 8-in.-dia pipe from the Three Mile Island No. 1 (PWR) spent fuel pool heat exchanger plumbing developed a through-wall crack. The crack was intergranular, initiating from the inside surface in a weld heat-affected zone. The zone where the crack occurred was severely sensitized during field welding. The Kraftwerk Union (Erlangen, GFR) disassembled a stainless-steel fuel-handling machine that operated for 12 y in a PWR (boric acid) spent fuel pool. There was no evidence of deterioration, and the fuel-handling machine was reassembled for further use. A spent fuel pool at a Swedish PWR was decontaminated. The procedure is outlined in this report

  7. Research program on the feasibility of pool type LMFBR in Japan

    International Nuclear Information System (INIS)

    Hattori, Sadao

    1982-01-01

    The Central Research Institute of Electric Power Industry has started the feasibility study to evaluate the possiblity of existence of large pool type FBR plants in Japan as the three-year project from fiscal 1981. The development of FBRs is indispensable for the effective use of nuclear fuel and the establishment of energy security. The knowledge on the characteristics of FBR core, sodium technology and others has advanced rapidly in Japan. At the stage of the practical reactors with large capacity, the pool type is naturally considered as the object of selection, but the aseismatic capability and safety of the large containment vessels for the pool type and the qualitative and quantitative acceptability of the research and development for the pool type are the problems. The difference between the loop type and the pool type is only the structural change arising from the difference in the arrangement of equipment. The pool type reactors have been operated already in the UK and France. The objective of the research and main subjects, the total plan and research organization, the fundamental condition of investigation, the research procedure for respective subjects, and the outline of model test are discribed. The change of design and safety standards in the future must be predicted and taken in consideration in the research. (Kako, I.)

  8. Assessment for markers of nephropathy in newly diagnosed type 2 ...

    African Journals Online (AJOL)

    Objective: To assess for markers of nephropathy in newly diagnosed type 2 diabetics, using blood pressure levels, endogenous creatinine clearance and urinary protein excretion as markers of renal disease. Study design: Ninety newly diagnosed type 2 diabetics were studied within 6 weeks of diagnosis. They were in ...

  9. Cryptosporidium and Giardia in Swimming Pools, Atlanta, Georgia

    Centers for Disease Control (CDC) Podcasts

    2008-05-29

    In this podcast, Dan Rutz speaks with Dr. Joan Shields, a guest researcher with the Healthy Swimming Program at CDC, about an article in June 2008 issue of Emerging Infectious Diseases reporting on the results of a test of swimming pools in the greater Atlanta, Georgia area. Dr. Shields tested 160 pools in metro Atlanta last year for Cryptosporidium and Giardia. These germs cause most recreational water associated outbreaks.  Created: 5/29/2008 by Emerging Infectious Diseases.   Date Released: 5/29/2008.

  10. 76 FR 72923 - Pool Corporation; Analysis To Aid Public Comment

    Science.gov (United States)

    2011-11-28

    ... manufacturers, warehouse them, and then resell the products to pool retail stores, pool service companies and.... ADDRESSES: Interested parties may file a comment online or on paper, by following the instructions in the... 0115'' on your comment, and file your comment online at https://ftcpublic.commentworks.com/ftc...

  11. 7 CFR 1007.7 - Pool plant.

    Science.gov (United States)

    2010-01-01

    ...-upon use other than Class I shall be excluded from the supply plant's shipments in computing the plant... under the order in this part, or such plant has automatic pooling status under such other order. (h) Any...

  12. Analysis of implementing phase change materials in open-air swimming pools

    OpenAIRE

    Zsembinszki, Gabriel; Farid, Mohammed M.; Cabeza, Luisa F.

    2012-01-01

    Open-air swimming pools in Mediterranean climate regions are heated by direct solar radiation with no auxiliary heating systems. In order to extend the swimming season or improve comfort conditions, solar collectors or pool coverings may be used. In this paper, another approach was followed through the use of phase change materials (PCM). Two methods of introducing the PCM were considered: (1) encapsulated in the sidewalls and bottom of the pool, and (2) use the PCM in an external he...

  13. Characteristics of pools used by adult summer steelhead oversummering in the New River, California

    Science.gov (United States)

    Rodney J. Nakamoto

    1994-01-01

    Abstract - I assessed characteristics of pools used by oversummering adults of summer steelhead Oncorhynchus mykiss between July and October 1991 in the New River, northwestern California. Most fish occupied channel confluence pools and other pools of moderate size (200-1,200 m 2); these pools had less than 35% substrate embeddedness and mean water depths of about 1.0...

  14. CERN Electronics Pool presentations

    CERN Multimedia

    2011-01-01

    The CERN Electronics Pool has organised a series of presentations in collaboration with oscilloscope manufacturers. The last one will take place according to the schedule below.   Time will be available at the end of the presentation to discuss your personal needs. The Agilent presentation had to be postponed and will be organised later. -     Lecroy: Thursday, 24 November 2011, in 530-R-030, 14:00 to 16:30.

  15. Induced venous pooling and cardiorespiratory responses to exercise after bed rest

    Science.gov (United States)

    Convertino, V. A.; Sandler, H.; Webb, P.; Annis, J. F.

    1982-01-01

    Venous pooling induced by a specially constructed garment is investigated as a possible means for reversing the reduction in maximal oxygen uptake regularly observed following bed rest. Experiments involved a 15-day period of bed rest during which four healthy male subjects, while remaining recumbent in bed, received daily 210-min venous pooling treatments from a reverse gradient garment supplying counterpressure to the torso. Results of exercise testing indicate that while maximal oxygen uptake endurance time and plasma volume were reduced and maximal heart rate increased after bed rest in the control group, those parameters remained essentially unchanged for the group undergoing venous pooling treatment. Results demonstrate the importance of fluid shifts and venous pooling within the cardiovascular system in addition to physical activity to the maintenance of cardiovascular conditioning.

  16. 14 CFR 26.39 - Newly produced airplanes: Fuel tank flammability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Newly produced airplanes: Fuel tank... Tank Flammability § 26.39 Newly produced airplanes: Fuel tank flammability. (a) Applicability: This... Series 767 Series (b) Any fuel tank meeting all of the criteria stated in paragraphs (b)(1), (b)(2) and...

  17. Expansion of the known Klebsiella pneumoniae species gene pool by characterization of novel alien DNA islands integrated into tmRNA gene sites.

    Science.gov (United States)

    Zhang, Jie; van Aartsen, Jon Jurriaan; Jiang, Xiaofei; Shao, Yucheng; Tai, Cui; He, Xinyi; Tan, Zhilei; Deng, Zixin; Jia, Shiru; Rajakumar, Kumar; Ou, Hong-Yu

    2011-02-01

    Klebsiella pneumoniae is an important bacterial pathogen of man that is commonly associated with opportunistic and hospital-associated infections. Increasing levels of multiple-antibiotic resistance associated with this species pose a major emerging clinical problem. This organism also occurs naturally in other diverse environments, including the soil. Consistent with its varied lifestyle and membership of the Enterobacteriaceae family, K. pneumoniae genomes exhibit highly plastic architecture comprising a core genome backbone interspersed with numerous and varied alien genomic islands. In this study the size of the presently known K. pneumoniae pan-genome gene pool was estimated through analysis of complete sequences of three chromosomes and 31 plasmids belonging to K. pneumoniae strains. In addition, using a PCR-based strategy the genomic content of eight tRNA/tmRNA gene sites that serve as DNA insertion hotspots were investigated in 28 diverse environmental and clinical strains of K. pneumoniae. Sequencing and characterization of five newly identified horizontally-acquired tmRNA-associated islands further expanded the archived K. pneumoniae gene pool to a total of 7648 unique gene members. Large-scale investigation of the content of tRNA/tmRNA hotspots will be useful to identify and/or survey accessory sequences dispersed amongst hundreds to thousands of members of many key bacterial species. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. A sequential vesicle pool model with a single release sensor and a ca(2+)-dependent priming catalyst effectively explains ca(2+)-dependent properties of neurosecretion

    DEFF Research Database (Denmark)

    Walter, Alexander M; da Silva Pinheiro, Paulo César; Verhage, Matthijs

    2013-01-01

    identified. We here propose a Sequential Pool Model (SPM), assuming a novel Ca(2+)-dependent action: a Ca(2+)-dependent catalyst that accelerates both forward and reverse priming reactions. While both models account for fast fusion from the Readily-Releasable Pool (RRP) under control of synaptotagmin-1...... the simultaneous changes in release rate and amplitude seen when mutating the SNARE-complex. Finally, it can account for the loss of fast- and the persistence of slow release in the synaptotagmin-1 knockout by assuming that the RRP is depleted, leading to slow and Ca(2+)-dependent fusion from the NRP. We conclude...... that the elusive 'alternative Ca(2+) sensor' for slow release might be the upstream priming catalyst, and that a sequential model effectively explains Ca(2+)-dependent properties of secretion without assuming parallel pools or sensors....

  19. ATAD2 is an epigenetic reader of newly synthesized histone marks during DNA replication.

    Science.gov (United States)

    Koo, Seong Joo; Fernández-Montalván, Amaury E; Badock, Volker; Ott, Christopher J; Holton, Simon J; von Ahsen, Oliver; Toedling, Joern; Vittori, Sarah; Bradner, James E; Gorjánácz, Mátyás

    2016-10-25

    ATAD2 (ATPase family AAA domain-containing protein 2) is a chromatin regulator harboring an AAA+ ATPase domain and a bromodomain, previously proposed to function as an oncogenic transcription co-factor. Here we suggest that ATAD2 is also required for DNA replication. ATAD2 is co-expressed with genes involved in DNA replication in various cancer types and predominantly expressed in S phase cells where it localized on nascent chromatin (replication sites). Our extensive biochemical and cellular analyses revealed that ATAD2 is recruited to replication sites through a direct interaction with di-acetylated histone H4 at K5 and K12, indicative of newly synthesized histones during replication-coupled chromatin reassembly. Similar to ATAD2-depletion, ectopic expression of ATAD2 mutants that are deficient in binding to these di-acetylation marks resulted in reduced DNA replication and impaired loading of PCNA onto chromatin, suggesting relevance of ATAD2 in DNA replication. Taken together, our data show a novel function of ATAD2 in cancer and for the first time identify a reader of newly synthesized histone di-acetylation-marks during replication.

  20. Trophic interactions among the heterotrophic components of plankton in man-made peat pools

    Directory of Open Access Journals (Sweden)

    Michał Niedźwiecki

    2017-03-01

    Full Text Available Man-made peat pools are permanent freshwater habitats developed due to non-commercial man-made peat extraction. Yet, they have not been widely surveyed in terms of ecosystem functioning, mainly regarding the complexity of heterotrophic components of the plankton. In this study we analysed distribution and trophic interrelations among heterotrophic plankton in man-made peat pools located in different types of peatbogs. We found that peat pools showed extreme differences in environmental conditions that occurred to be important drivers of distribution of microplankton and metazooplankton. Abundance of bacteria and protozoa showed significant differences, whereas metazooplankton was less differentiated in density among peat pools. In all peat pools stress-tolerant species of protozoa and metazoa were dominant. In each peat pool five trophic functional groups were distinguished. The abundance of lower functional trophic groups (bacteria, heterotrophic nanoflagellates (HNF and ciliates feeding on bacteria and HNF was weakly influenced by environmental drivers and was highly stable in all peat pool types. Higher functional trophic groups (naupli, omnivorous and carnivorous ciliates, cladocerans, adult copepods and copepodites were strongly influenced by environmental variables and exhibited lower stability. Our study contributes to comprehensive knowledge of the functioning of peat bogs, as our results have shown that peat pools are characterized by high stability of the lowest trophic levels, which can be crucial for energy transfer and carbon flux through food webs.