WorldWideScience

Sample records for neutron field dosimetry

  1. Neutron personal dosimetry: state-of-art

    International Nuclear Information System (INIS)

    Spurný, František

    2005-03-01

    State-of-art of the personal neutron dosimetry is presented, analysed and discussed. Particular attention is devoted to the problems of this type of the dosimetry of external exposure for radiation fields at nuclear power plants. A review of general problems of neutron dosimetry is given and the active individual dosimetry methods available and/or in the stage of development are briefly reviewed. Main attention is devoted to the analysis of the methods available for passive individual neutron dosimetry. The characteristics of these dosemeters were studied and are compared: their energy response functions, detection thresholds and the highest detection limits, the linearity of response, the influence of environmental factors, etc. Particular attention is devoted to their behavior in reactor neutron fields. It is concluded that the choice of the neutron personal dosemeter depends largely on the conditions in which the instrument should be used (neutron spectrum, the level of exposure and the exposure rate, etc.). The results obtained with some of these dosemeters during international intercomparisons are also presented. Particular attention is paid to the personal neutron dosimeter developed and routinely used by National Personal Dosimetry Service Ltd. in the Czech Republic. (author)

  2. EPR dosimetry in a mixed neutron and gamma radiation field.

    Science.gov (United States)

    Trompier, F; Fattibene, P; Tikunov, D; Bartolotta, A; Carosi, A; Doca, M C

    2004-01-01

    Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident absorbed dose, analyzed results show the EPR potentiality and complementarity with regular criticality techniques.

  3. Biological dosimetry for mixed gamma-neutron field

    International Nuclear Information System (INIS)

    Brandao, J.O.C.; Santos, J.A.L.; Souza, P.L.G.; Lima, F.F.; Vilela, E.C.; Calixto, M.S.; Santos, N.

    2011-01-01

    There is increasing concern about airline crew members (about one million worldwide) exposed to measurable neutrons doses. Historically, cytogenetic biodosimetry assays have been based on quantifying asymmetrical chromosome alterations (dicentrics, centric rings and acentric fragments) in mitogen-stimulated T-lymphocytes in their first mitosis after radiation exposure. Increased levels of chromosome damage in peripheral blood lymphocytes are a sensitive indicator of radiation exposure and they are routinely exploited for assessing radiation absorbed dose after accidental or occupational exposure. Since radiological accidents are not common, not all nations feel that it is economically justified to maintain biodosimetry competence. However, dependable access to biological dosimetry capabilities is completely critical in event of an accident. In this paper the dose-response curve was measured for the induction of chromosomal alterations in peripheral blood lymphocytes after chronic exposure in vitro to mixed gamma-neutron field. Blood was obtained from one healthy donor and exposed to two mixed gamma-neutron field from sources 241 AmBe (20 Ci) at the Neutron Calibration Laboratory (NCL - CRCN/NE - PE - Brazil). The evaluated absorbed doses were 0.2 Gy; 1.0 Gy and 2.5 Gy. The dicentric chromosomes were observed at metaphase, following colcemide accumulation and 1000 well-spread metaphases were analyzed for the presence of dicentrics by two experts after painted by giemsa 5%. The preliminary results showed a linear dependence between radiations absorbed dose and dicentric chromosomes frequencies. Dose-response curve described in this paper will contribute to the construction of calibration curve that will be used in our laboratory for biological dosimetry. (author)

  4. Review of microscopic integral cross section data in fundamental reactor dosimetry benchmark neutron fields

    International Nuclear Information System (INIS)

    Fabry, A.; McElroy, W.N.; Kellogg, L.S.; Lippincott, E.P.; Grundl, J.A.; Gilliam, D.M.; Hansen, G.E.

    1976-01-01

    This paper is intended to review and critically discuss microscopic integral cross section measurement and calculation data for fundamental reactor dosimetry benchmark neutron fields. Specifically the review covers the following fundamental benchmarks: the spontaneous californium-252 fission neutron spectrum standard field; the thermal-neutron induced uranium-235 fission neutron spectrum standard field; the (secondary) intermediate-energy standard neutron field at the center of the Mol-ΣΣ, NISUS, and ITN-ΣΣ facilities; the reference neutron field at the center of the Coupled Fast Reactor Measurement Facility; the reference neutron field at the center of the 10% enriched uranium metal, cylindrical, fast critical; the (primary) Intermediate-Energy Standard Neutron Field

  5. Discussions in symposium 'neutron dosimetry in neutron fields - from detection techniques to medical applications'

    International Nuclear Information System (INIS)

    Tanimura, Y.; Sato, T.; Kumada, H.; Terunuma, T.; Sakae, T.; Harano, H.; Matsumoto, T.; Suzuki, T.; Matsufuji, N.

    2008-01-01

    Recently the traceability system (JCSS) of neutron standard based on the Japanese law 'Measurement Act' has been instituted. In addition, importance of the neutron dose evaluation has been increasing in not only the neutron capture medical treatment but also the proton or heavy particle therapy. Against such a background, a symposium 'Neutron dosimetry in neutron fields - From detection techniques to medical applications-' was held on March 29, 2008 and recent topics on the measuring instruments and their calibration, the traceability system, the simulation technique and the medical applications were introduced. This article summarizes the key points in the discussion at the symposium. (author)

  6. Review of microscopic integral cross section data in fundamental reactor dosimetry benchmark neutron fields

    International Nuclear Information System (INIS)

    Fabry, A.; McElroy, W.N.; Kellogg, L.S.; Lippincott, E.P.; Grundl, J.A.; Gilliam, D.M.; Hansen, G.E.

    1976-10-01

    The paper is intended to review and critically discuss microscopic integral cross section measurement and calculation data for fundamental reactor dosimetry benchmark neutron fields. Specifically the review covers the following fundamental benchmarks: (1) the spontaneous californium-252 fission neutron spectrum standard field; (2) the thermal-neutron induced uranium-235 fission neutron spectrum standard field; (3) the (secondary) intermediate-energy standard neutron field at the center of the Mol-ΣΣ, NISUS, and ITN--ΣΣ facilities; (4) the reference neutron field at the center of the Coupled Fast Reactor Measurement Facility (CFRMF); (5) the reference neutron field at the center of the 10 percent enriched uranium metal, cylindrical, fast critical; and (6) the (primary) Intermediate-Energy Standard Neutron Field

  7. Proceedings of the 5. symposium on neutron dosimetry. Beam dosimetry

    International Nuclear Information System (INIS)

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantitites, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  8. Neutron dosimetry - A review

    Energy Technology Data Exchange (ETDEWEB)

    Baum, J W

    1955-03-29

    This review summarizes information on the following subjects: (1) physical processes of importance in neutron dosimetry; (2) biological effects of neutrons; (3) neutron sources; and (4) instruments and methods used in neutron dosimetry. Also, possible improvements in dosimetry instrumentation are outlined and discussed. (author)

  9. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  10. Dosimetry of the Embalse nuclear power plant neutron/gamma mixed fields

    International Nuclear Information System (INIS)

    Salas, C.A.

    1990-01-01

    The aim of this work is to describe the method used at the Embalse nuclear power plant for carrying out personal dosimetry of the agents affected to the tasks on the Embalse nuclear power plant neutron-gamma mixed fields. (Author) [es

  11. 5th symposium on neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Spurny, F

    1985-03-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of /sup 252/Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.).

  12. 5th symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.

    1985-01-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of 252 Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.)

  13. Intercomparison of personnel dosimetry for thermal neutron dose equivalent in neutron and gamma-ray mixed fields

    International Nuclear Information System (INIS)

    Ogawa, Yoshihiro

    1985-01-01

    In order to consider the problems concerned with personnel dosimetry using film badges and TLDs, an intercomparison of personnel dosimetry, especially dose equivalent responses of personnel dosimeters to thermal neutron, was carried out in five different neutron and gamma-ray mixed fields at KUR and UTR-KINKI from the practical point of view. For the estimation of thermal neutron dose equivalent, it may be concluded that each personnel dosimeter has good performances in the precision, that is, the standard deviations in the measured values by individual dosimeter were within 24 %, and the dose equivalent responses to thermal neutron were almost independent on cadmium ratio and gamma-ray contamination. However, the relative thermal neutron dose equivalent of individual dosimeter normalized to the ICRP recommended value varied considerably and a difference of about 4 times was observed among the dosimeters. From the results obtained, it is suggested that the standardization of calibration factors and procedures is required from the practical point of radiation protection and safety. (author)

  14. Status of neutron cross sections for reactor dosimetry

    International Nuclear Information System (INIS)

    Vlasov, M.F.; Fabry, A.; McElroy, W.N.

    1977-03-01

    The status of current international efforts to develop standardized sets of evaluated energy-dependent (differential) neutron cross sections for reactor dosimetry is reviewed. The status and availability of differential data are considered, some recent results of the data testing of the ENDF/B-IV dosimetry file using 252 Cf and 235 U benchmark reference neutron fields are presented, and a brief review is given of the current efforts to characterize and identify dosimetry benchmark radiation fields

  15. Benchmark referencing of neutron dosimetry measurements

    International Nuclear Information System (INIS)

    Eisenhauer, C.M.; Grundl, J.A.; Gilliam, D.M.; McGarry, E.D.; Spiegel, V.

    1980-01-01

    The concept of benchmark referencing involves interpretation of dosimetry measurements in applied neutron fields in terms of similar measurements in benchmark fields whose neutron spectra and intensity are well known. The main advantage of benchmark referencing is that it minimizes or eliminates many types of experimental uncertainties such as those associated with absolute detection efficiencies and cross sections. In this paper we consider the cavity external to the pressure vessel of a power reactor as an example of an applied field. The pressure vessel cavity is an accessible location for exploratory dosimetry measurements aimed at understanding embrittlement of pressure vessel steel. Comparisons with calculated predictions of neutron fluence and spectra in the cavity provide a valuable check of the computational methods used to estimate pressure vessel safety margins for pressure vessel lifetimes

  16. Performance of neutron and gamma personnel dosimetry in mixed radiation fields

    International Nuclear Information System (INIS)

    Swaja, R.E.; Sims, C.S.

    1981-01-01

    From 1974 to 1980, six personnel dosimetry intercomparison studies (PDIS) were conducted at the Oak Ridge National Laboratory (ORNL) to evaluate the performance of personnel dosimeters in a variety of neutron and gamma fields produced by operating the Health Physics Research Reactor (HPRR) in the steady state mode with and without spectral modifying shields. A total of 58 different organizations participated in these studies which produced approximately 2000 measurements of neutron and gamma dose equivalents on anthropomorphic phantoms for five different reactor spectra. Based on these data, the relative performance of three basic types of neutron dosimeters [nuclear emulsion film, thermoluminescent (TLD), and track-etch] and two basic types of gamma dosimeters (film and TLD) in mixed radiation fields was assessed

  17. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  18. Measurements of Integral Cross Section Ratios in Two Dosimetry Benchmark Neutron Fields

    International Nuclear Information System (INIS)

    Fabry, A.; Czock, K.H.

    1974-12-01

    In the frame of a current interlaboratory effort devoted to the standardization of fuels and materials neutron dosimetry, the 103 Rh(n,n') 103m Rh and 58 Ni(n,p) 58 Co integral cross sections have been accurately measured relatively to the 115 In(n,n') 115m In cross section in the 235 U thermal dission neutron spectrum and in the MOLΣΣ Intermediate-Energy Standard Neutron field. In this last neutron field, the data are related also to the 235 U(n,f) cross section. The measurements are extensively documented and the results briefly compared to literature. Most noticeably, decisive support is provided for the selection of a specific 103 Rh(n,n') 103m Rh differential-energy cross section among the existing, conflicting data. (author)

  19. Measurements of integral cross section ratios in two dosimetry benchmark neutron fields

    International Nuclear Information System (INIS)

    Fabry, A.; Czock, K.H.

    1974-12-01

    In the frame of a current interlaboratory effort devoted to the standardization of fuels and materials neutron dosimetry, the 103 Rh(n,n') 103m Rh and 58 Ni(n,p) 58 Co integral cross sections have been accurately measured relatively to the 115 In(n,n') 115m In cross section in the 235 U thermal fission neutron spectrum and in the MOL-ΣΣ intermediate-energy standard neutron field. In this last neutron field, the data are related also to the 235 U(n,f) cross section. The measurements are extensively documented and the results briefly compared to literature. Most noticeably, decisive support is provided for the selection of a specific 103 Rh(n,n') 103m Rh differential-energy cross section among the existing, conflicting data. (author)

  20. Individual neutron dosimetry

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  1. ESR-dosimetry in thermal and epithermal neutron fields for application in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, Tobias

    2016-01-22

    Dosimetry is essential for every form of radiotherapy. In Boron Neutron Capture Therapy (BNCT) mixed neutron and gamma fields have to be considered. Dose is deposited in different neutron interactions with elements in the penetrated tissue and by gamma particles, which are always part of a neutron field. The therapeutic dose in BNCT is deposited by densely ionising particles, originating from the fragmentation of the isotope boron-10 after capture of a thermal neutron. Despite being investigated for decades, dosimetry in neutron beams or fields for BNCT remains complex, due to the variety in type and energy of the secondary particles. Today usually ionisation chambers combined with metal foils are used. The applied techniques require extensive effort and are time consuming, while the resulting uncertainties remain high. Consequently, the investigation of more effective techniques or alternative dosimeters is an important field of research. In this work the possibilities of ESR-dosimeters in those fields have been investigated. Certain materials, such as alanine, generate stable radicals upon irradiation. Using Electron Spin Resonance (ESR) spectrometry the amount of radicals, which is proportional to absorbed dose, can be quantified. Different ESR detector materials have been irradiated in the thermal neutron field of the research reactor TRIGA research reactor in Mainz, Germany, with five setups, generating different secondary particle spectra. Further irradiations have been conducted in two epithermal neutron beams. The detector response, however, strongly depends on the dose depositing particle type and energy. It is hence necessary to accompany measurements by computational modelling and simulation. In this work the Monte Carlo code FLUKA was used to calculate absorbed doses and dose components. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using amorphous track models. For the simulation, detailed models of

  2. Fast neutron dosimetry

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Pearson, D.W.

    1992-01-01

    This progress report concentrates on two major areas of dosimetry research: measurement of fast neutron kerma factors for several elements for monochromatic and white spectrum neutron fields and determination of the response of thermoluminescent phosphors to various ultra-soft X-ray energies and beta-rays. Dr. Zhixin Zhou from the Shanghai Institute of Radiation Medicine, People's Republic of China brought with him special expertise in the fabrication and use of ultra-thin TLD materials. Such materials are not available in the USA. The rather unique properties of these materials were investigated during this grant period

  3. Mixed field dosimetry with paired ionization chambers

    International Nuclear Information System (INIS)

    Coppola, M.; Porro, F.

    1977-01-01

    This report describes the results of neutron and gamma mixed-field dosimetry obtained by the Ispra Group in the framework of the European Neutron Dosimetry intercomparison Project (ENDIP). The experimental method and the formulation employed for the derivation of Kerma results are also present

  4. Measurements of integral cross section ratios in two dosimetry benchmark neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Fabry, A [CEN-SCK, Mol (Belgium); Czock, K H [International Atomic Energy Agency, Laboratory Seibersdorf, Vienna (Austria)

    1974-12-01

    In the frame of a current interlaboratory effort devoted to the standardization of fuels and materials neutron dosimetry, the {sup 103}Rh(n,n'){sup 103m}Rh and {sup 58}Ni(n,p){sup 58}Co integral cross sections have been accurately measured relatively to the {sup 115}In(n,n'){sup 115m} In cross section in the {sup 235}U thermal fission neutron spectrum and in the MOL-{sigma}{sigma} intermediate-energy standard neutron field. In this last neutron field, the data are related also to the {sup 235}U(n,f) cross section. The measurements are extensively documented and the results briefly compared to literature. Most noticeably, decisive support is provided for the selection of a specific {sup 103}Rh(n,n'){sup 103m}Rh differential-energy cross section among the existing, conflicting data. (author)

  5. Measurements of Integral Cross Section Ratios in Two Dosimetry Benchmark Neutron Fields

    Energy Technology Data Exchange (ETDEWEB)

    Fabry, A. [CEN-SCK, Mol (Belgium); Czock, K. H. [International Atomic Energy Agency, Vienna (Austria)

    1974-12-15

    In the frame of a current interlaboratory effort devoted to the standardization of fuels and materials neutron dosimetry, the {sup 103}Rh(n,n'){sup 103m}Rh and {sup 58}Ni(n,p){sup 58}Co integral cross sections have been accurately measured relatively to the {sup 115}In(n,n'){sup 115m}In cross section in the {sup 235}U thermal dission neutron spectrum and in the MOL{Sigma}{Sigma} Intermediate-Energy Standard Neutron field. In this last neutron field, the data are related also to the {sup 235}U(n,f) cross section. The measurements are extensively documented and the results briefly compared to literature. Most noticeably, decisive support is provided for the selection of a specific {sup 103}Rh(n,n'){sup 103m}Rh differential-energy cross section among the existing, conflicting data. (author)

  6. Personnel neutron dose assessment upgrade: Volume 1, Personnel neutron dosimetry assessment: [Final report

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Brackenbush, L.W.; Griffith, R.V.; Hankins, D.E.; Parkhurst, M.A.; Stroud, C.M.; Faust, L.G.; Vallario, E.J.

    1988-07-01

    This report provides guidance on the characteristics, use, and calibration criteria for personnel neutron dosimeters. The report is applicable for neutrons with energies ranging from thermal to less than 20 MeV. Background for general neutron dosimetry requirements is provided, as is relevant federal regulations and other standards. The characteristics of personnel neutron dosimeters are discussed, with particular attention paid to passive neutron dosimetry systems. Two of the systems discussed are used at DOE and DOE-contractor facilities (nuclear track emulsion and thermoluminescent-albedo) and another (the combination TLD/TED) was recently developed. Topics discussed in the field applications of these dosimeters include their theory of operation, their processing, readout, and interpretation, and their advantages and disadvantages for field use. The procedures required for occupational neutron dosimetry are discussed, including radiation monitoring and the wearing of dosimeters, their exchange periods, dose equivalent evaluations, and the documenting of neutron exposures. The coverage of dosimeter testing, maintenance, and calibration includes guidance on the selection of calibration sources, the effects of irradiation geometries, lower limits of detectability, fading, frequency of calibration, spectrometry, and quality control. 49 refs., 6 figs., 8 tabs

  7. Fast neutron spectrometry and dosimetry; Spectrometrie et dosimetrie des neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Blaize, S; Ailloud, J; Mariani, J; Millot, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author)Fren. [French] Nous avons etudie la spectrometrie et la dosimetrie des neutrons rapides en utilisant les protons de recul qu'ils produisent dans une matiere hydrogenee. En spectrometrie, nous avons employe des emulsions nucleaires, en dosimetrie, du polyethylene recouvert de sulfure de zinc place devant un photomultiplicateur. (auteur)

  8. European protocol for neutron dosimetry for external beam therapy

    International Nuclear Information System (INIS)

    Broerse, J.J.; Mijnheer, B.J.; Williams, J.R.

    1981-01-01

    The paper attempts to serve the needs of European centres participating in the High LET Therapy Project Group set up under the sponsorship of The European Organization for Research on Treatment of Cancer, to promote cooperation between physicists involved in fast neutron therapy and establish a common basis for neutron dosimetry. Differences in dosimetry procedures between European and American Groups are indicated if relevant. The subject is dealt with under the following main headings: principles of dosimetry of neutron fields, dosimetric methods, physical parameters, determination of absorbed dose at a reference point, determination of absorbed dose at any point, check of absorbed dose given to a patient, dosimetry intercomparisons between institutes. There is an ample bibliography. (U.K.)

  9. The calibration method for personal dosimetry system in photon and neutron radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J; Plichta, J [CSOD, Prague (Czech Republic); Nikodemova, D [SOD, Bratislava (Slovakia)

    1996-12-31

    The type testing of dosimetry system was performed with standard photon radiation fields within the energy range 15 keV to 1.25 MeV and electron radiation fields within the range 0.2 MeV to 3 MeV. For type testing of neutron dosimeters {sup 252}Cf and {sup 241}Am-Be radionuclide neutron sources was used, as well as a 14 MeV neutron generator. The neutron sources moderated by various moderating and absorbing materials was also used. The routine calibration of individual photon dosemeters was carried out using a {sup 137}Cs calibration source in the air kerma quality in the dose range 0.2 mGy to 6 Gy. The type testing of neutron dosemeters was performed in collaboration with Nueherberg laboratory on neutron generator with neutron energies -.57; 1.0;; 5.3 and 15.1 MeV. The fading and angular dependence testing was also included in the tests of both dosemeter systems. (J.K.).

  10. Neutron dosimetry: problems, solutions, prospects and the role of trace detectors

    International Nuclear Information System (INIS)

    Fernandez, F.

    2009-10-01

    It is present in schematic way, the origin of the neutrons; their interaction with matter, until its application in the field of dosimetry. It describes some measuring instruments based on thermoluminescence dosimetry, some activation detectors and trace detectors. Finally, it summarizes the work in neutron dosimetry have been carried out at the Autonomous University of Barcelona. (Author)

  11. Status report on dosimetry benchmark neutron field development, characterization, and application

    International Nuclear Information System (INIS)

    Fabry, A.; Grundl, J.A.; McElroy, W.N.; Lippincott, E.P.; Farrar, H. IV.

    1977-01-01

    The report attempts to present a brief, but comprehensive review of the status and future directions of benchmark neutron field development, characterization and application in perspective with two major objectives of reactor dosimetry: (1) fuel fission rate and burn-up passive monitoring, and (2) correlation of materials irradiation damage effects and projection to commercial power plants. The report focuses on the Light Water Reactor and Fast Breeder Reactor program needs

  12. Eurados trial performance test for neutron personal dosimetry

    DEFF Research Database (Denmark)

    Bordy, J.M.; Stadtmann, H.; Ambrosi, P.

    2001-01-01

    This paper reports on the results of a neutron trial performance test sponsored by the European Commission and organised by EURADOS. As anticipated, neutron dosimetry results were very dependent on the dosemeter type and the dose calculation algorithm. Fast neutron fields were generally well...

  13. Personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  14. Improving neutron dosimetry using bubble detector technology

    International Nuclear Information System (INIS)

    Buckner, M.A.

    1993-02-01

    Providing accurate neutron dosimetry for a variety of neutron energy spectra is a formidable task for any dosimetry system. Unless something is known about the neutron spectrum prior to processing the dosimeter, the calculated dose may vary greatly from that actually encountered; that is until now. The entrance of bubble detector technology into the field of neutron dosimetry has eliminated the necessity of having an a priori knowledge of the neutron energy spectra. Recently, a new approach in measuring personnel neutron dose equivalent was developed at Oak Ridge National Laboratory. By using bubble detectors in combination with current thermoluminescent dosimeters (TLDs) as a Combination Personnel Neutron Dosimeter (CPND), not only is it possible to provide accurate dose equivalent results, but a simple four-interval neutron energy spectrum is obtained as well. The components of the CPND are a Harshaw albedo TLD and two bubble detectors with theoretical energy thresholds of 100 key and 1500 keV. Presented are (1) a synoptic history surrounding emergence of bubble detector technology, (2) a brief overview of the current theory on mechanisms of interaction, (3) the data and analysis process involved in refining the response functions, (4) performance evaluation of the original CPND and a reevaluation of the same data under the modified method, (5) the procedure used to determine the reference values of component fluence and dose equivalent for field assessment, (6) analysis of the after-modification results, (7) a critique of some currently held assumptions, offering some alternative explanations, and (8) thoughts concerning potential applications and directions for future research

  15. Neutron Dosimetry

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2001-01-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding

  16. Bubble detectors as a tool of the dosimetry and microdosimetry in neutron fields

    International Nuclear Information System (INIS)

    Spurny, F.; Vlcek, B.; Rannou, A.

    1998-01-01

    Two types of bubble detector were studied: the Bubble Damage Neutron Detector (BDND) and the Superheated Drop Detector (SDD). The detectors were tested in neutron beams and fields. The relative response of the detectors varied with the average neutron energy. The response of SDD 100 started to decrease at higher energies than for BDND's, at 100 keV it was only about 1/4 of the response to AmBe neutrons. The responses of SDD 1000 and SDD 6000 decreased with the average neutron energy in a rather similar way. Starting from the AmLi source they represented less than 0.1 of the response to AmBe neutrons. Their response to high energy neutrons was practically the same as to AmBe neutrons. This is important for individual air crew dosimetry on board aircraft. (M.D.)

  17. Neutron Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Vanhavere, F

    2001-04-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding.

  18. Using track detectors in neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The usage of track detectors of charged particles provides a new possibility of neutron dosimetry. Presented is a comparison of the main dosimetric characteristics of three various types of track detectots of fast neutrons, i.e. glass in the contact with 232 Th; KODAK LR115 cellulose nitrate; MAKROFOL E polycarbonate. Results of studing energy dependences of detectors are presented. Results obtained using phantoms under radiation fields of various sources of complex gamma-neutron radiation are discussed [ru

  19. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1982-01-01

    The measurement of neutron exposures to personnel is an issue that has received increased attention in the last few years. It is important to consider key aspects of the whole dosimetry system when developing dose estimates. This begins with selection of proper dosimeters and survey instruments, and extends through the calibration methods. One must match the spectral response and sensitivity of the dosimeter to the spectral characteristics of the neutron fields. Threshold detectors that are insensitive to large fractions of neutrons in the lower energy portion of reactor spectra should be avoided. Use of two or more detectors with responses that complement each other will improve measurement quality. It is important to understand the spectral response of survey instruments, so that spectra which result in significant overresponse do not lead to overestimation of dose. Calibration sources that do not match operational field spectra can contribute to highly erroneous results. In those situations, in-field calibration techniques should be employed. Although some detection developments have been made in recent years, a lot can be done with existing technology until fully satisfactory, long term solutions are obtained

  20. Neutron dosimetry in biology

    International Nuclear Information System (INIS)

    Sigurbjoernsson, B.; Smith, H.H.; Gustafsson, A.

    1965-01-01

    To study adequately the biological effects of different energy neutrons it is necessary to have high-intensity sources which are not contaminated by other radiations, the most serious of which are gamma rays. An effective dosimetry must provide an accurate measure of the absorbed dose, in biological materials, of each type of radiation at any reactor facility involved in radiobiological research. A standardized biological dosimetry, in addition to physical and chemical methods, may be desirable. The ideal data needed to achieve a fully documented dosimetry has been compiled by H. Glubrecht: (1) Energy spectrum and intensity of neutrons; (2) Angular distribution of neutrons on the whole surface of the irradiated object; (3) Additional undesired radiation accompanying the neutrons; (4) Physical state and chemical composition of the irradiated object. It is not sufficient to note only an integral dose value (e.g. in 'rad') as the biological effect depends on the above data

  1. Eleventh DOE workshop on personnel neutron dosimetry

    International Nuclear Information System (INIS)

    1991-01-01

    Since its formation, the Office of Health (EH-40) has stressed the importance of the exchange of information related to and improvements in neutron dosimetry. This Workshop was the eleventh in the series sponsored by the Department of Energy (DOE). It provided a forum for operational personnel at DOE facilities to discuss current issues related to neutron dosimetry and for leading investigators in the field to discuss promising approaches for future research. A total of 26 papers were presented including the keynote address by Dr. Warren K. Sinclair, who spoke on, ''The 1990 Recommendations of the ICRP and their Biological Background.'' The first several papers discussed difficulties in measuring neutrons of different energies and ways of compensating or deriving correction factors at individual facilities. Presentations were also given by the US Navy and Air Force. Current research in neutron dosimeter development was the subject of the largest number of papers. These included a number on the development of neutron spectrometers

  2. High sensitivity MOSFET-based neutron dosimetry

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Konstantakos, V.; Zamani, M.; Siskos, S.; Laopoulos, T.; Sarrabayrouse, G.

    2010-01-01

    A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS Laboratory, Toulouse, France. In order to be used for neutron dosimetry, a thin film of lithium fluoride was deposited on the surface of the gate of the device. The characteristics of the dosemeter, such as the dependence of its response to neutron dose and dose rate, were investigated. The studied dosemeter was very sensitive to gamma rays compared to other dosemeters proposed in the literature. Its response in thermal neutrons was found to be much higher than in fast neutrons and gamma rays.

  3. Proceedings of the 5. Symposium on neutron dosimetry. Radiation protection aspects

    International Nuclear Information System (INIS)

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantities, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  4. Workplace monitoring of mixed neutron-photon radiation fields and its contribution to external dosimetry

    International Nuclear Information System (INIS)

    Schuhmacher, H.

    2011-01-01

    Workplace monitoring is a common procedure for determining measures for routine radiation protection in a particular working environment. For mixed radiation fields consisting of neutrons and photons, it is of increased importance because it contributes to the improved accuracy of individual monitoring. An example is the determination of field-specific correction factors, which can be applied to the readings of personal dosemeters. This paper explains the general problems associated with individual dosimetry of neutron radiation, and describes the various options for workplace monitoring. These options cover a range from the elaborate field characterisation using transport calculations or spectrometers to the simpler approach using area monitors. Examples are given for workplaces in nuclear industry, at particle accelerators and at flight altitudes. (authors)

  5. Neutron dosimetry for radiation damage in fission and fusion reactors

    International Nuclear Information System (INIS)

    Smith, D.L.

    1979-01-01

    The properties of materials subjected to the intense neutron radiation fields characteristic of fission power reactors or proposed fusion energy devices is a field of extensive current research. These investigations seek important information relevant to the safety and economics of nuclear energy. In high-level radiation environments, neutron metrology is accomplished predominantly with passive techniques which require detailed knowledge about many nuclear reactions. The quality of neutron dosimetry has increased noticeably during the past decade owing to the availability of new data and evaluations for both integral and differential cross sections, better quantitative understanding of radioactive decay processes, improvements in radiation detection technology, and the development of reliable spectrum unfolding procedures. However, there are problems caused by the persistence of serious integral-differential discrepancies for several important reactions. There is a need to further develop the data base for exothermic and low-threshold reactions needed in thermal and fast-fission dosimetry, and for high-threshold reactions needed in fusion-energy dosimetry. The unsatisfied data requirements for fission reactor dosimetry appear to be relatively modest and well defined, while the needs for fusion are extensive and less well defined because of the immature state of fusion technology. These various data requirements are examined with the goal of providing suggestions for continued dosimetry-related nuclear data research

  6. Personnel neutron dosimetry at Department of Energy facilities

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.; Selby, J.M.; Vallario, E.J.

    1980-08-01

    This study assesses the state of personnel neutron dosimetry at DOE facilities. A survey of the personnel dosimetry systems in use at major DOE facilities was conducted, a literature search was made to determine recent advances in neutron dosimetry, and several dosimetry experts were interviewed. It was concluded that personnel neutron dosimeters do not meet current needs and that serious problems exist now and will increase in the future if neutron quality factors are increased and/or dose limits are lowered

  7. Neutron personnel dosimetry considerations for fusion reactors

    International Nuclear Information System (INIS)

    Barton, T.P.; Easterly, C.E.

    1979-07-01

    The increasing development of fusion reactor technology warrants an evaluation of personnel neutron dosimetry systems to aid in the concurrent development of a radiation protection program. For this reason, current state of knowledge neutron dosimeters have been reviewed with emphasis placed on practical utilization and the problems inherent in each type of dosimetry system. Evaluations of salient parameters such as energy response, latent image instability, and minimum detectable dose equivalent are presented for nuclear emulsion films, track etch techniques, albedo and other thermoluminescent dosimetry techniques, electrical conductivity damage effects, lyoluminescence, thermocurrent, and thermally stimulated exoelectron emission. Brief summaries of dosimetry regulatory requirements and intercomparison study results help to establish compliance and recent trends, respectively. Spectrum modeling data generated by the Neutron Physics Division of Oak Ridge National Laboratory for the Princeton Tokamak Fusion Test Reactor (TFTR) Facility have been analyzed by both International Commission on Radiological Protection fluence to dose conversion factors and an adjoint technique of radiation dosimetry, in an attempt to determine the applicability of current neutron dosimetry systems to deuterium and tritium fusion reactor leakage spectra. Based on the modeling data, a wide range of neutron energies will probably be present in the leakage spectra of the TFTR facility, and no appreciable risk of somatic injury to occupationally exposed workers is expected. The relative dose contributions due to high energy and thermal neutrons indicate that neutron dosimetry will probably not be a serious limitation in the development of fusion power

  8. Neutron Dosimetry and Irradiation of Solids; Dosimetrie des neutrons et irradiation des solides

    Energy Technology Data Exchange (ETDEWEB)

    Perriot, G; Schmitt, A P [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1962-07-01

    Results of work at C.E.A. from 1958 to 1960 are reviewed. The possibilities offered by classical dosimetry methods are discussed. The tests which led to the utilization, for fast neutron dosimetry, of resistivity variations induced in solid W by such neutrons are described. Experimental W irradiation results led to a definition of neutron efficiency which describes the relations between neutron energy and their effects on materials. Possibilities offered by detectors which make use of radiation damage and are sensitive to neutrons at keV energies were explored. In other work, the principal French reactors were classified according to their ability to produce damage in materials such as W. (authors) [French] Dans ce rapport on a presente les resultats essentiels de travaux qui ont ete effectues de 1958 a 1980 par des chercheurs du CEA issus de differents services. En meme temps qu'une revue des possibilites offertes a l'epoque par les methodes classiques de dosimetrie (utilisation des detecteurs par activation), on a decrit les essais qui devaient permettre d'utiliser, a la dosimetrie les neutrons rapides, les variations de resistivite qu'ils creent dans un corps solide (tungstene). L'irradiation du tungstene a montre l'importance qu'il y avait a definir 'l'efficacite' des neutrons, c'est-a-dire leur aptitude plus ou moins grande, selon leur energie, a creer des defauts dans les materiaux. L'efficacite d'un emplacement d'irradiation se trouvant liee au spectre neutronique, on a vu les difficultes qu'il y avait a utiliser les detecteurs par activation des qu'on n'avait plus affaire a un spectre en 1/E ou de fission et on a pu entrevoir les possibilites offertes par les detecteurs utilisant la creation des defauts qui repondent a tous les neutrons d'energies, superieures a quelques keV. Enfin, on a classe les principaux types de Piles Francaises selon leur aptitude a creer plus ou moins rapidement des dommages dans des materiaux comme le tungstene. (auteur)

  9. Mixed field dosimetry with the twin chamber technique

    International Nuclear Information System (INIS)

    Burger, G.; Maier, E.

    1974-04-01

    For the separate dosimetry of the neutron- and gamma-component in a mixed beam it is principally possible to use two ionization chambers with different ratios of neutron- to gamma sensitivity. Several authors proposed for this purpose the use of a homogenious TE-chamber filled with the TE-gas and of a carbon-chamber filled with CO 2 -gas. This chamber combination is also commercially available in several countries. The chambers are normally equipped with a continuous gas-flow provision and with a waterproof-housing for the use within liquid phantoms. The application of such chambers for mixed field dosimetry in the intercomparison project of the ICRU at the RARAF-facility in Brookhaven (International Neutron Dosimetry Intercomparison - INDI) is described. (orig./HP) [de

  10. EVIDOS: Individual dosimetry in mixed neutron and photon radiation fields

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2006-01-01

    The EVIDOS project (partly funded by the European Commission RTD Programme: Nuclear Energy, Euratom Framework Programme V, 1998-2002, Contract No FIKR-CT-2001-00175) aimed at improving individual monitoring in mixed neutron-photon radiation fields by evaluating the performance of routine and novel personal dosimeters for mixed radiation, and by giving guidelines for deriving sufficiently accurate values of personal dose equivalent from the readings of area survey instruments and dosimeters. The main objective of EVIDOS was to evaluate different methods for individual dosimetry in mixed neutron-photon work-places in nuclear industry. This implied a determination of the capabilities and limitations of personal dosimeters and the establishment of methods to enable sufficiently accurate values of personal dose equivalent from spectrometers, area survey instruments and routine personal dosimeters. Also novel electronic personal dosimeters were investigated. To this end spectrometric and dosimetric investigations in selected representative workplaces in nuclear industry where workers can receive significant neutron doses were performed. As part of this project, a number of tasks were executed, in particular: (1) the determination of the energy and direction distribution of the neutron fluence; (2) the derivation of the (conventionally true) values of radiation protection quantities; (3) the determination of the readings of routine and innovative personal dosimeters and of area monitors; and (4) the comparison between dosimeter readings and values of the radiation protection quantities

  11. Reactor dosimetry integral reaction rate data in LMFBR Benchmark and standard neutron fields: status, accuracy and implications

    International Nuclear Information System (INIS)

    Fabry, A.; Ceulemans, H.; Vandeplas, P.; McElroy, W.N.; Lippincott, E.P.

    1977-01-01

    This paper provides conclusions that may be drawn regarding the consistency and accuracy of dosimetry cross-section files on the basis of integral reaction rate data measured in U.S. and European benchmark and standard neutron fields. In a discussion of the major experimental facilities CFRMF (Idaho Falls), BIGTEN (Los Alamos), ΣΣ (Mol, Bucharest), NISUS (London), TAPIRO (Roma), FISSION SPECTRA (NBS, Mol, PTB), attention is paid to quantifying the sensitivity of computed integral data relative to the presently evaluated accuracy of the various neutron spectral distributions. The status of available integral data is reviewed and the assigned uncertainties are appraised, including experience gained by interlaboratory comparisons. For all reactions studied and for the various neutron fields, the measured integral data are compared to the ones computed from the ENDF/B-IV and the SAND-II dosimetry cross-section libraries as well as to some other differential data in relevant cases. This comparison, together with the proposed sensitivity and accuracy assessments, is used, whenever possible, to establish how well the best cross-sections evaluated on the basis of differential measurements (category I dosimetry reactions) are reliable in terms of integral reaction rates prediction and, for those reactions for which discrepancies are indicated, in which energy range it is presumed that additional differential measurements might help. For the other reactions (category II), the inconsistencies and trends are examined. The need for further integral measurements and interlaboratory comparisons is also considered

  12. Fast neutron dosimetry: Progress summary

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.

    1988-01-01

    The purpose was to investigate the radiological physics and biology of very low energy photons derived from a 1-GeV electron synchrotron storage ring. An extensive beam line and irradiation apparatus was designed, developed, and constructed. Dosimetry measurements required invention and testing of a miniature absolute calorimeter and a cell irradiation fixture suitable for scanning exposures under computer control. Measurements of the kerma factors of oxygen, aluminum and silicon for 14-20 MeV neutrons. Custom designed miniature proportional counters of cylindrical symmetry were employed in these determinations. The oxygen kerma factor was found significantly lower than values calculated from microscopic cross sections. We also tested Mg and Fe walled conventional spherical counters. The direct neutron-counting gas interaction is significant enough for these counters that a correction is needed. We also investigated the application of Nuclear Magnetic Resonance spectroscopy to radiation dosimetry. Our purpose was to take advantage of recent development of very high-field magnets, complex RF-pulse techniques for solvent suppression, and improved spectral analysis techniques

  13. The Martin Marietta Energy Systems personnel neutron dosimetry program

    International Nuclear Information System (INIS)

    McMahan, K.L.

    1991-01-01

    Martin Marietta Energy Systems, Inc. (Energy Systems), manages five sites for the US Department of Energy. Personnel dosimetry for four of the five sites is coordinated through a Centralized External Dosimetry System (CEDS). These four sites are the Oak Ridge National Laboratory (ORNL), the Oak Ridge Y-12 Plant (Y-12), the Oak Ridge K-25 Site (K-25), and the Paducah Gaseous Diffusion Plant (PGDP). The fifth Energy Systems site, Portsmouth Gaseous Diffusion Plant, has an independent personnel dosimetry program. The current CEDS personnel neutron dosimeter was first issued in January 1989, after an evaluation and characterization of the dosimeters' response in the workplaces was performed. For the workplace characterization, Energy Systems contracted with Pacific Northwest Laboratory (PNL) to perform neutron measurements at selected locations at ORNL and Y-12. K-25 and PGDP were not included because their neutron radiation fields were similar to others already planned for characterization at ORNL and Y-12. Since the initial characterization, PNL has returned to Oak Ridge twice to perform follow up measurements, and another visit is planned in the near future

  14. Dosimetry of clinical neutron and proton beams: An overview of recommendations

    International Nuclear Information System (INIS)

    Vynckier, S.

    2004-01-01

    Neutron therapy beams are obtained by accelerating protons or deuterons on Beryllium. These neutron therapy beams present comparable dosimetric characteristics as those for photon beams obtained with linear accelerators; for instance, the penetration of a p(65) + Be neutron beam is comparable with the penetration of an 8 MV photon beam. In order to be competitive with conventional photon beam therapy, the dosimetric characteristics of the neutron beam should therefore not deviate too much from the photon beam characteristics. This paper presents a brief summary of the neutron beams used in radiotherapy. The dosimetry of the clinical neutron beams is described. Finally, recent and future developments in the field of physics for neutron therapy is mentioned. In the last two decades, a considerable number of centres have established radiotherapy treatment facilities using proton beams with energies between 50 and 250 MeV. Clinical applications require a relatively uniform dose to be delivered to the volume to be treated, and for this purpose the proton beam has to be spread out, both laterally and in depth. The technique is called 'beam modulation' and creates a region of high dose uniformity referred to as the 'spread-out Bragg peak'. Meanwhile, reference dosimetry in these beams had to catch up with photon and electron beams for which a much longer tradition of dosimetry exists. Proton beam dosimetry can be performed using different types of dosemeters, such as calorimeters, Faraday cups, track detectors and ionisation chambers. National standard dosimetry laboratories will, however, not provide a standard for the dosimetry of proton beams. To achieve uniformity on an international level, the use of an ionisation chamber should be considered. This paper reviews and summarises the basic principles and recommendations for the absorbed dose determination in a proton beam, utilising ionisation chambers calibrated in terms of absorbed dose to water. These recommendations

  15. Dosimetry methods in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D. [Universita degli Studi di Milano, Department of Physics, Via Festa del Patrono 7, 20122 Milano (Italy); Agosteo, S.; Barcaglioni, L. [Istituto Nazionale di Fisica Nucleare, Milano (Italy); Campi, F.; Garlati, L. [Politecnico di Milano, Energy Department, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); De Errico, F. [Universita degli Studi di Pisa, Department of Civil and Industrial Engineering, Lungamo Pacinotti 43, 56126 Pisa (Italy); Borroni, M.; Carrara, M. [Fondazione IRCCS Istituto Nazionale Tumori, Medical Physics Unit, Via Venezian 1, 20133 Milano (Italy); Burian, J.; Klupak, V.; Viererbl, L.; Marek, M. [Research Centre Rez, Department of Neutron Physics, 250-68 Husinec-Rez (Czech Republic)

    2014-08-15

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  16. Dosimetry methods in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D.; Agosteo, S.; Barcaglioni, L.; Campi, F.; Garlati, L.; De Errico, F.; Borroni, M.; Carrara, M.; Burian, J.; Klupak, V.; Viererbl, L.; Marek, M.

    2014-08-01

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  17. Personal dosimetry in a mixed field of high energy muons and neutrons

    International Nuclear Information System (INIS)

    Cossairt, J.D.; Elwyn, A.J.

    1986-11-01

    High energy accelerators quite often emit muons. These particles behave in matter as would heavy electrons and are thus difficult to attenuate with shielding in many situations. Hence, these muons can be a source of radiation exposure to personnel and suitable methods of measuring the absorbed dose received to these people is obviously required. In practical situations, such muon radiation fields are often mixed with neutrons, well-known to be an even more troublesome particle species with respect to dosimetry. In this paper, we report on fluence measurements made in such a mixed radiation field and a comparison of dosimeter responses. We conclude that commercial self-reading dosimeters and film badges provided an adequate measure of the absorbed dose due to muons

  18. Sixth symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    1987-01-01

    This booklet contains all abstracts of papers presented in 13 sessions. Main topics: Cross sections and Kerma factors; analytical radiobiology; detectors for personnel monitoring; secondary charged particles and microdosimetric basis of q-value for neutrons; personnel dosimetry; concepts for radiation protection; ambient monitoring; TEPC and ion chambers in radiation protection; beam dosimetry; track detectors (CR-39); dosimetry at biomedical irradiation facilities; health physics at therapy facilities; calibration for radiation protection; devices for beam dosimetry (TLD and miscellaneous); therapy and biomedical irradiation facilities; treatment planning. (HP)

  19. Some aspects on neutron dosimetry

    International Nuclear Information System (INIS)

    Henaish, B.A.; Youssef, S.K.

    1988-01-01

    The American National Council on Radiation Protection and measurements (1) has recently issued a statement regarding dose limitation system for neutrons. The changes proposed in that statement presented substantial problems regarding the personnel exposure to neutrons and had pointed out the need to reassess an adequate current neutron dosimetry practice. Generally, the same types of dosimeters i.e. Nuclear Track (NTA films) and TLD-Albedo, have been used at major nuclear facilities over the past 15 years. here recently, other dosimetry methods such as track etch with polycarbonates such as CR-39 have been developed. However these should be recognized as local systems aiming to the development of better and more applicable dosimeters. 4 tab

  20. New laser technique revives old ideas for thermoluminescence neutron dosimetry

    International Nuclear Information System (INIS)

    Braeunlich, P.; Brown, M.; Gasiot, J.; Fillard, J.P.

    1982-01-01

    Laser heating is discussed as a means to evaluate thermoluminescence dosimeters in neutron dosimetry. Direct energy coupling from the photon beam to the phonons of the TL material permits heating of thin layers with rates of temperature increase exceeding 10 4 Ks - 1 . Rapid TLD evaluation will allow the design of dosimetry badges containing a number of different small thin film TLD elements in various orientations and behind appropriate filters, hydrogenous radiators, etc. Desired redundance is readily possible by using back-up TLDs for every specific task. Reading occurs with a scanning laser beam rather than by mechanically manipulating the TLD toward a fixed heat source. Improvements in the signal-to-noise ratio of up to a factor of 1000 are readily obtained. Thus, sensitive thin-film TLDs can be designed with negligible self-shielding for thermal neutrons in albedo applications and with known, nearly energy dependent cavity correction factors for dosimetry in mixed n-#betta# fields. Due to the greatly increased sensitivity possible with fast laser heating, significant advances are expected in the fast neutron dosimetry techniques which are based on hydrogeneous proton radiators or LET-dependent slow peak formation

  1. Neutron beam measurement dosimetry

    International Nuclear Information System (INIS)

    Amaro, C.R.

    1995-01-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR

  2. Automatic neutron dosimetry system based on fluorescent nuclear track detector technology

    International Nuclear Information System (INIS)

    Akselrod, M.S.; Fomenko, V.V.; Bartz, J.A.; Haslett, T.L.

    2014-01-01

    For the first time, the authors are describing an automatic fluorescent nuclear track detector (FNTD) reader for neutron dosimetry. FNTD is a luminescent integrating type of detector made of aluminium oxide crystals that does not require electronics or batteries during irradiation. Non-destructive optical readout of the detector is performed using a confocal laser scanning fluorescence imaging with near-diffraction limited resolution. The fully automatic table-top reader allows one to load up to 216 detectors on a tray, read their engraved IDs using a CCD camera and optical character recognition, scan and process simultaneously two types of images in fluorescent and reflected laser light contrast to eliminate false-positive tracks related to surface and volume crystal imperfections. The FNTD dosimetry system allows one to measure neutron doses from 0.1 mSv to 20 Sv and covers neutron energies from thermal to 20 MeV. The reader is characterised by a robust, compact optical design, fast data processing electronics and user-friendly software. The first table-top automatic FNTD neutron dosimetry system was successfully tested for LLD, linearity and ability to measure neutrons in mixed neutron-photon fields satisfying US and ISO standards. This new neutron dosimetry system provides advantages over other technologies including environmental stability of the detector material, wide range of detectable neutron energies and doses, detector re-readability and re-usability and all-optical readout. A new adaptive image processing algorithm reliably removes false-positive tracks associated with surface and bulk crystal imperfections. (authors)

  3. Safeguards and Physics Measurements: Neutron Dosimetry

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2000-01-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations as well as to investigate the charcteristics of bubble detectors in order to be able to use them as direct-readiong neutron dosemeters

  4. Dosimetry of fast neutrons

    International Nuclear Information System (INIS)

    Jahr, R.

    1975-03-01

    Following an explanation of the physical fundamentals of neutron dosimetry, the special needs in medicine and biology are gone into. It is shown that the dose equivalent used in radiation protection simplifies in an undue manner the complicated dependence of the biological effects. The reason for this is the fact that the RBE for heavy recoil nuclei, amongst others, depends on the energy and sort of particle, whereas it is approximately equal to one for electrons independent of the energy. It is thus necessary in the fields of biology and medicine to have additional information on energy spectra of the neutrons as well as of all charged secondary particles as a function of the position in the phantom. These are obtained partly by calculation and partly by special dosemeters. The accuracy achieved so far is 5%. (ORU/LH) [de

  5. Tenth DOE workshop on personnel neutron dosimetry

    International Nuclear Information System (INIS)

    1984-06-01

    The purpose of this workshop is to promote the international exchange of information on neutron dosimetry. The development of an accurate real-time dosemeter is an immediate need which must be met. Assessment of the neutron dose equivalent at low doses with a reasonable degree of accuracy must be accomplished to provide validity to exposure records. These and other aspects of personal neutron dosimetry are discussed. Separate abstracts have been prepared for each paper for inclusion in the Energy Data Base

  6. Future developments in etched track detectors for neutron dosimetry

    International Nuclear Information System (INIS)

    Tommasino, L.

    1987-01-01

    Many laboratories engaged in the field of personal neutron dosimetry are interested in developing better etching processes and improving the CR-39 detecting materials. To know how much effort must still be devoted to the development of etch track dosimetry, it is necessary to understand the advantages. limitations and degree of exploitation of the currently available techniques. So much has been learned about the chemical and electrochemical etching processes that an optimised combination of etching processes could make possible the elimination of many of the existing shortcomings. Limitations of etched track detectors for neutron dosimetry arise mainly because the registration occurs only on the detector surface. These damage type detectors are based on radiation induced chain scission processes in polymers, which result in hole-type tracks in solids. The converse approach, yet to be discovered, would be the development of cure-track detectors, where radiation induced cross linking between organic polymer chains could result in solid tracks in liquids. (author)

  7. Fast neutron dosimetry and spectrometry using radioactivation (1963); Dosimetrie et spectrometrie des neutrons rapides par radioactivation (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Lamberieux, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The author first recalls rapidly a few generalities concerning induced radioactivity detectors and gives, in an appendix, tables summarizing the properties of detector elements which may be used in radioprotection. The excitation functions found in the literature and also given. The technological characteristics of the detectors used are given, together with the counting methods. The many advantages of activation dosimetry for strong or periodic neutron fluxes and for those in the presence of {gamma}-radiation are stressed. The main problem in activation dosimetry is, however, the calculation of the dose absorbed from the results of the measurements. It is shown how the dose is expressed, fairly accurately, as a function of the radioactivities induced in a series of detectors. As an example, the spectrometry and the dosimetry of the neutron flux emitted by a Po-Be source are presented. (author) [French] L'auteur fait d'abord un bref rappel des generalites sur les detecteurs a radioactivite induite, accompagne, en annexe, des tableaux resumant les proprietes d'elements detecteurs utilisables en radioprotection. Les fonctions d'excitation trouvees dans la litterature y sont egalement annexees. On donne ensuite les caracteristiques technologiques des detecteurs employes ainsi que les methodes de comptage utilisees. On souligne les nombreux avantages de la dosimetrie par activation dans les flux de neutrons intenses ou periodiques et en presence de rayonnement {gamma}. Il reste que le probleme central de la dosimetrie par activation est le calcul de la dose absorbee a partir des resultats de mesure. On montre comment la dose s'exprime, de maniere approchee, en fonction des radioactivites induites dans une serie de detecteurs. A titre d'exemple, la spectrometrie et la dosimetrie du flux de neutrons emis par une source de Po-Be sont presentees. (auteur)

  8. Neutron Reference Benchmark Field Specification: ACRR Free-Field Environment (ACRR-FF-CC-32-CL).

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Richard Manuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Parma, Edward J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffin, Patrick J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vehar, David W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity free-field reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

  9. Field calibration of PADC track etch detectors for local neutron dosimetry in man using different radiation qualities

    Energy Technology Data Exchange (ETDEWEB)

    Haelg, Roger A., E-mail: rhaelg@phys.ethz.ch [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Besserer, Juergen [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Boschung, Markus; Mayer, Sabine [Division for Radiation Safety and Security, Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Clasie, Benjamin [Department of Radiation Oncology, Massachusetts General Hospital, 30 Fruit Street, Boston, MA 02114 (United States); Kry, Stephen F. [Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Schneider, Uwe [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 204, CH-8057 Zurich (Switzerland)

    2012-12-01

    In order to quantify the dose from neutrons to a patient for contemporary radiation treatment techniques, measurements inside phantoms, representing the patient, are necessary. Published reports on neutron dose measurements cover measurements performed free in air or on the surface of phantoms and the doses are expressed in terms of personal dose equivalent or ambient dose equivalent. This study focuses on measurements of local neutron doses inside a radiotherapy phantom and presents a field calibration procedure for PADC track etch detectors. An initial absolute calibration factor in terms of H{sub p}(10) for personal dosimetry is converted into neutron dose equivalent and additional calibration factors are derived to account for the spectral changes in the neutron fluence for different radiation therapy beam qualities and depths in the phantom. The neutron spectra used for the calculation of the calibration factors are determined in different depths by Monte Carlo simulations for the investigated radiation qualities. These spectra are used together with the energy dependent response function of the PADC detectors to account for the spectral changes in the neutron fluence. The resulting total calibration factors are 0.76 for a photon beam (in- and out-of-field), 1.00 (in-field) and 0.84 (out-of-field) for an active proton beam and 1.05 (in-field) and 0.91 (out-of-field) for a passive proton beam, respectively. The uncertainty for neutron dose measurements using this field calibration method is less than 40%. The extended calibration procedure presented in this work showed that it is possible to use PADC track etch detectors for measurements of local neutron dose equivalent inside anthropomorphic phantoms by accounting for spectral changes in the neutron fluence.

  10. Dosimetry and biological effects of fast neutrons

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1981-01-01

    This thesis contains studies on two types of cellular damage: cell reproductive death and chromosome aberrations induced by irradiation with X rays, gamma rays and fast neutrons of different energies. A prerequisite for the performance of radiobiological experiments is the determination of the absorbed dose with a sufficient degree of accuracy and precision. Basic concepts of energy deposition by ionizing radiation and practical aspects of neutron dosimetry for biomedical purposes are discussed. Information on the relative neutron sensitivity of GM counters and on the effective point of measurement of ionization chambers for dosimetry of neutron and photon beams under free-in-air conditions and inside phantoms which are used to simulate the biological objects is presented. Different methods for neutron dosimetry are compared and the experimental techniques used for the investigations of cell reproductive death and chromosome aberrations induced by ionizing radiation of different qualities are presented. Dose-effect relations for induction cell inactivation and chromsome aberrations in three cultured cell lines for different radiation qualities are presented. (Auth.)

  11. Neutron dosimetry at SLAC: Neutron sources and instrumentation

    International Nuclear Information System (INIS)

    Liu, J.C.; Jenkins, T.M.; McCall, R.C.; Ipe, N.E.

    1991-10-01

    This report summarizes in detail the dosimetric characteristics of the five radioisotopic type neutron sources ( 238 PuBe, 252 Cf, 238 PuB, 238 PuF 4 , and 238 PuLi) and the neutron instrumentation (moderated BF 3 detector, Anderson-Braun (AB) detector, AB remmeter, Victoreen 488 Neutron Survey Meter, Beam Shut-Off Ionization Chamber, 12 C plastic scintillator detector, moderated indium foil detector, and moderated and bare TLDs) that are commonly used for neutron dosimetry at the Stanford Linear Accelerator Center (SLAC). 36 refs,. 19 figs

  12. Neutron dosimetry program at Mound - problems and solutions

    International Nuclear Information System (INIS)

    Winegardner, M.K.

    1991-01-01

    The Mound personnel neutron dosimetry program utilizes TLD albedo technology. The neutron dosimeter design incorporates a two-element spectrometer for site-specific neutron quality determination and empirical application of field neutron calibration factors. Design elements feature two Li(6)F (TLD- 600) chips for neutron detection and one Li(7)F (TLD-700) chip for gamma compensation of the TLD- 600 chips. One TLD-600 chip is Cadmium shielded on the front side of the dosimeter, the other is Cadmium shielded from the back side. Tin filters are placed opposite of the Cadmium shield on each of the TLD-600 chips and on both sides of the TLD-700 chip for symmetrically equivalent gamma absorption characteristics. Neutron quality determination is accomplished by the albedo neutron-to- incident thermal neutron response ratio above the Cadmium cutoff. This front Cadmium shielded-to-back Cadmium shielded response ratio, compensated for the presence of gamma radiation, provides the basis for neutron energy calibration via the albedo response curve

  13. Neutron dosimetry at SLAC: Neutron sources and instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J.C.; Jenkins, T.M.; McCall, R.C.; Ipe, N.E.

    1991-10-01

    This report summarizes in detail the dosimetric characteristics of the five radioisotopic type neutron sources ({sup 238}PuBe, {sup 252}Cf, {sup 238}PuB, {sup 238}PuF{sub 4}, and {sup 238}PuLi) and the neutron instrumentation (moderated BF{sub 3} detector, Anderson-Braun (AB) detector, AB remmeter, Victoreen 488 Neutron Survey Meter, Beam Shut-Off Ionization Chamber, {sup 12}C plastic scintillator detector, moderated indium foil detector, and moderated and bare TLDs) that are commonly used for neutron dosimetry at the Stanford Linear Accelerator Center (SLAC). 36 refs,. 19 figs.

  14. Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications

    International Nuclear Information System (INIS)

    Zoetelief, J.; Broerse, J.J.

    1983-01-01

    The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation chamber employing a number of physical parameters. To arrive at the charge produced in the cavity several correction factors have to be introduced which are related to the operational characteristics of the chambers. Information on the operational characteristics of four TE ionisation chambers is presented in relation to ion collection, density and composition of gas in the cavity, wall thickness and effective point of measurement. In addition, some recent results from an ionisation chamber operated at high gas pressures are presented. The total absorbed doses derived from TE ionisation chambers show agreement within the uncertainty limits with results from other independent dosimetry methods, i.e., differential fluence measurements and a TE calorimeter. Conscientious experimentation and a common data base can provide dosimetry results with TE ionisation chambers with variations of less than +-2%. (author)

  15. Dosimetry techniques of thermal neutrons and {gamma} radiation in reactor cores; Techniques de dosimetrie des neutrons thermiques et du rayonnement {gamma} dans les piles

    Energy Technology Data Exchange (ETDEWEB)

    Sutton, J; Draganic, I; Hering, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    Chemical studies under radiation done in the reactor cores require to be followed by dosimetry. When the irradiations are done in the reflector, one can limit to the measure of the {gamma} and the neutron radiation. For the dosimetry of the {gamma} radiation, a dosimeter of ferrous sulfate is convenient until doses of about 10{sup 6} rep. The use of aired oxalic acid solutions permits to reach 10{sup 7} rep. The dosimetry of thermal neutrons has been made with solutions of cobalt sulphate or paper filter impregnated with this salt. The total chemical effect of the {gamma} and of the slow neutrons radiation is obtained with solutions of ferrous sulfate added with lithium sulphate. (M.B.) [French] Les etudes de chimie sous radiation faites dans les piles exigent d'etre suivies par dosimetrie. Lorsque les irradiations sont effectues dans le reflecteur, on peut se limiter a doser le rayonnement {gamma} et les neutrons. Pour la dosimetrie du rayonnement {gamma}, un dosimetre a sulfate ferreux convient jusqu'a des doses d'environ 10{sup 6} rep. L'emploi de solutions aerees d'acide oxalique permet d'atteindre 10{sup 7} rep. La dosimetrie des neutrons thermiques a ete faite avec des solutions de sulfate de cotalt ou du papier filtre impregne de ce sel. L'effet chimique total du rayonnement {gamma} et des neutrons lents est obtenu avec des solutions de sulfate ferreux additionne de sulfate de lithium. (M.B.)

  16. Personnel neutron dosimetry using electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.; Westermark, J.

    1986-01-01

    A personnel neutron dosimetry system has been developed based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This Cr-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. The dosimetry system employs an electrochemical etch procedure that be used to process large numbers of Cr-39 dosimeters. The etch procedure is suitable for operations where the number of personnel requires that many CR-39 dosimeters be processed. Experience shows that one full-time technician can etch and evaluate 2000 foils per month. The energy response to neutrons is fairly flat from about 80 keV to 3.5 MeV, but drops by about a factor of three in the 13 to 16 MeV range. The sensitivity of the dosimetry system is about 7 tracks/cm 2 /mrem, with a background equivalent to about 8 mrem for new CR-39 foils. The limit of sensitivity is approximately 10 mrem. The dosimeter has a significant variation in directional dependence, dropping to about 20% at 90 0 . This dosimeter has been used for personnel neutron dosimetry at the Lawrence Livermore National Laboratory for more tha 18 months. 6 refs., 23 figs., 2 tabs

  17. Fast neutron dosimetry

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Pearson, D.W.

    1991-01-01

    During 1988--1990 the magnetic resonance dosimetry project was completed, as were the 250 MeV proton shielding measurements. The first cellular experiment using human cells in vitro at the 1 GeV electron storage ring was also accomplished. More detail may be found in DOE Report number-sign DOE/EV/60417-002 and the open literature cited in the individual progress subsections. We report Kinetic Energy Released in Matter (KERMA), factor measurements in several elements of critical importance to neutron radiation therapy and radiation protection for space habitation and exploration for neutron energies below 30 MeV. The results of this effort provide the only direct measurements of the oxygen and magnesium kerma factors above 20 MeV neutron energy, and the only measurements of the iron kerma factor above 15 MeV. They provide data of immediate relevance to neutron radiotherapy and impose strict criteria for normalizing and testing nuclear models used to calculate kerma factors at higher neutron energies

  18. Investigations of CR39 dosimeters for neutron routine dosimetry

    International Nuclear Information System (INIS)

    Weinstein, M.; Abraham, A.; Tshuva, A.; German, U.

    2004-01-01

    CR-39 is a polymeric nuclear track detector which is widely used for neutron dosimetry. CR-39 detector development was conducted at a number of laboratories throughout the world(1,2) , and was accepted also for routine dosimetry. However, there are shortcomings which must be taken into consideration the lack of a dosimetry grade material which causes batch variations, significant angular dependence and a moderate sensitivity. CR-39 also under-responds for certain classes of neutron spectra (lower energy neutrons from reactors or high energy accelerator-produced neutrons).In order to introduce CR-39 as a routine dosimeter at NRCN, a series of checks were performed. The present work describes the results of some of our checks, to characterize the main properties of CR-39 dosimeters

  19. Neutron dosimetry; Dosimetria de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Fratin, Luciano

    1993-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is

  20. Neutron dosimetry; Dosimetria de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Fratin, Luciano

    1994-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is

  1. Individual Dosimetry for High Energy Radiation Fields

    International Nuclear Information System (INIS)

    Spurny, F.

    1999-01-01

    The exposure of individuals on board aircraft increased interest in individual dosimetry in high energy radiation fields. These fields, both in the case of cosmic rays as primary radiation and at high energy particle accelerators are complex, with a large diversity of particle types, their energies, and linear energy transfer (LET). Several already existing individual dosemeters have been tested in such fields. For the component with high LET (mostly neutrons) etched track detectors were tested with and without fissile radiators, nuclear emulsions, bubble detectors for both types available and an albedo dosemeter. Individual dosimetry for the low LET component has been performed with thermoluminescent detectors (TLDs), photographic film dosemeters and two types of electronic individual dosemeters. It was found that individual dosimetry for the low LET component was satisfactory with the dosemeters tested. As far as the high LET component is concerned, there are problems with both the sensitivity and the energy response. (author)

  2. Application of solid state track detector to neutron dosimetry

    International Nuclear Information System (INIS)

    Tsuruta, Takao

    1979-01-01

    Though solid state track detectors (SSTD) are radiation measuring instrument for heavy charged particles by itself, it can be used as radiation measuring instrument for neutrons, if nuclear reactions such as (n, f) or (n, α) reaction are utilized. Since the means was found, which permits to observe the tracks of heavy charged particles in a solid with an optical microscope by chemically etching the tracks to enlarge them to etch pits, various types of detectors have been developed for the purpose of measuring neutron dose. The paper is described on the materials and construction of the SSTDs for neutron dosimetry, and the sensitivity is explained with mathematical equations. The features of neutron dosimetry with SSTDs are as follows: They are compact, and scarcely disturb neutron field, thus delicate dose distribution can be known; integration measurement is possible regardless of dose rate values because of integrating type detectors; it is not influenced by β-ray or γ-ray except the case when there is high energy radiation such as causing photonuclear reactions or high dose such as degrading solids, it has pretty high sensitivity; track fading is negligible during the normal measuring time around room temperature; and the etching images of tracks are relatively clear, and various automatic counting systems can be employed. (Wakatsuki, Y.)

  3. Tissue equivalence in neutron dosimetry

    International Nuclear Information System (INIS)

    Nutton, D.H.; Harris, S.J.

    1980-01-01

    A brief review is presented of the essential features of neutron tissue equivalence for radiotherapy and gives the results of a computation of relative absorbed dose for 14 MeV neutrons, using various tissue models. It is concluded that for the Bragg-Gray equation for ionometric dosimetry it is not sufficient to define the value of W to high accuracy and that it is essential that, for dosimetric measurements to be applicable to real body tissue to an accuracy of better than several per cent, a correction to the total absorbed dose must be made according to the test and tissue atomic composition, although variations in patient anatomy and other radiotherapy parameters will often limit the benefits of such detailed dosimetry. (U.K.)

  4. The Hiroshima neutron dosimetry enigma: Missing puzzle piece No. 6

    International Nuclear Information System (INIS)

    Gold, Raymond

    1999-01-01

    More than a decade has elapsed since the serious nature of the discrepancy between neutron dosimetry experiments (E) and neutron transport calculations (C) for the Hiroshima site was identified. Since that time extensive efforts to resolve this Hiroshima neutron dosimetry enigma have not only failed, but now demonstrate that the magnitude of this discrepancy is much greater than initially estimated. The currently evaluated E/C ratio for thermal neutron fluence at the Hiroshima site increases rapidly with increasing slant range from the epicenter. In the slant range region beyond 1000 m, E/C exceeds unity by one to two orders of magnitude depending on the specific dosimetry data that are utilized. Principal features that characterize the Hiroshima neutron dosimetry enigma are summarized. Puzzle Piece No. 6: In-situ production and Prompt fallout of radionuclides from Little Boy is advanced as a possible contributory phenomenon to this enigma. (The atom bomb detonated over Hiroshima was called Little Boy.) Measurements of 60 Co and 152 Eu specific activity at the Hiroshima site are used to obtain order of magnitude numerical estimates that show this conjecture is plausible. Comparison of different 60 Co measurements at the Hiroshima site reveals that the variation of E/C with slant range depends on the method used to quantify 60 Co specific activity as well as the type of dosimetry samples that are employed. These 60 Co comparisons lend additional qualitative credence to this conjecture. Within the limits of presently available data, these assessments show that Puzzle Piece No. 6 qualitatively satisfies the principal features that characterize the Hiroshima neutron dosimetry enigma. Nevertheless, current lack of data prevent this conjecture from being conclusively confirmed or refuted. Consequently, specific recommendations are advanced to resolve the Hiroshima neutron dosimetry enigma with emphasis on experimental tests that can quantitatively evaluate Puzzle Piece

  5. Neutron dosimetry at a high-energy electron-positron collider

    Science.gov (United States)

    Bedogni, Roberto

    Electron-positron colliders with energy of hundreds of MeV per beam have been employed for studies in the domain of nuclear and sub-nuclear physics. The typical structure of such a collider includes an LINAC, able to produce both types of particles, an accumulator ring and a main ring, whose diameter ranges from several tens to hundred meters and allows circulating particle currents of several amperes per beam. As a consequence of the interaction of the primary particles with targets, shutters, structures and barriers, a complex radiation environment is produced. This paper addresses the neutron dosimetry issues associated with the operation of such accelerators, referring in particular to the DAΦ NE complex, operative since 1997 at INFN-Frascati National Laboratory (Italy). Special attention is given to the active and passive techniques used for the spectrometric and dosimetric characterization of the workplace neutron fields, for radiation protection dosimetry purposes.

  6. DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    Science.gov (United States)

    Forouzan, Faezeh; Waker, Anthony J

    2018-01-10

    The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was investigated over a range of 20 keV (X-ray) to 0.661 MeV (Cs-137 gamma ray). Then, with both the counters used simultaneously, the neutron and gamma ray doses produced by a P385 Neutron Generator (Thermo Fisher Scientific) together with a Cs-137 gamma source were determined. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Dosimetry of an accident in mixed field (neutrons, photons) using the spectrometry by electronic paramagnetic resonance(EPR)

    International Nuclear Information System (INIS)

    Herve, M.L.

    2006-03-01

    In a radiological accident, the assessment of the dose received by the victim is relevant information for the therapeutic strategy. Two complementary dosimetric techniques based on physical means are used in routine practice in the laboratory: EPR spectroscopy performed on materials removed from the victim or gathered from the vicinity of the victim and Monte Carlo calculations. EPR dosimetry, has been used successfully several times in cases of photon or electron overexposures. Accidental exposure may also occur with a neutron component. The aim of this work is to investigate the potentiality of EPR dosimetry for mixed photon and neutron field exposure with different organic materials (ascorbic acid, sorbitol, glucose, galactose, fructose, mannose, lactose and sucrose). The influence of irradiation parameters (dose, dose rate, photon energy) and of environmental parameters (temperature of heating, light exposure) on the EPR signal amplitude was studied. To assess the neutron sensitivity, the materials were exposed to a mixed radiation field of experimental reactors with different neutron to photon ratios. The relative neutron sensitivity was found to range from 10% to 43% according to the materials. Prior knowledge of the ratio between the dose in samples measured by EPR spectrometry and organ or whole body dose obtained by calculations previously performed for these different configurations, makes it possible to give a first estimation of the dose received by the victim in a short delay. The second aim of this work is to provide data relevant for a quick assessment of the dose distribution in case of accidental overexposure based on EPR measurements performed on one or several points of the body. The study consists in determining by calculation the relation between the dose to the organs and whole body and the dose to specific points of the body, like teeth, bones or samples located in the pockets of victim clothes, for different external exposures corresponding

  8. Review on individual neutron dosimetry

    International Nuclear Information System (INIS)

    Portal, M.

    1983-01-01

    Up to now, nuclear energy workers in relation to neutron radiations were few. Fast development of nuclear energy lead us to study, for future, individual dosimetry techniques which are autonomous, more accurate and cheaper. The future dosemeter will be a couple: fast neutron dosemeter and slow neutron dosemeter. The different current studies concerning this ''composite'' dosemeter are described. In 1984-1985, operation of a ''non-homogeneous, composite'' dosemeter is foreseen; later on, an ''homogeneous composite'' dosemeter that is to say a dosemeter which needs same basis techniques [fr

  9. Integral test of JENDL dosimetry file using fast neutron field in the Experimental Fast Reactor JOYO

    International Nuclear Information System (INIS)

    Aoyama, Takafumi; Sekine, Takashi

    1999-09-01

    In order to evaluate the applicability of the JENDL dosimetry file, an integral test using a fast neutron spectrum field in the Experimental Fast Reactor JOYO Mark-II core was performed. The dosimeter set consisting of eight reactions of 46 Ti(n,p) 46 Sc, 54 Fe(n,p) 54 Mn, 58 Fe(n,γ) 59 Fe, 58 Ni(n,p) 58 Co, 59 Co(n,γ) 60 Co, 63 Cu(n,α) 60 Co, 238 U fission and 237 Np fission was irradiated for approximately 30 days near the core center of the JOYO Mk-II. Neutron flux at the dosimeter position was calculated using the two dimensional discrete ordinate transport code 'DORT'. The core configuration was modeled in XY geometry, and the 100 group cross section set of JSD-J2 / JFT-J2, which was processed from JENDL-2, was utilized. The absolute value of neutron flux was normalized so that the 235 U fission rate using the calculated neutron spectrum agreed with the measured reaction rate. The 103 group cross section data were processed by 'NJOY' code for nuclides to be used in the JOYO dosimetry. As the results of integral test for JENDL/D-99 (new file) and JENDL/D-91 (previous file), calculated values by JENDL/D-99 agreed well with the experimental values, and the C/E ratios ranged from 0.95 to 1.22. By comparing the results between JENDL/D-99 and JENDL/D-91, small differences exist, except for 58 Fe(n, γ) 59 Fe reaction, which was improved significantly in JENDL/D-99. (author)

  10. JENDL Dosimetry File

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu; Iguchi, Tetsuo; Kobayashi, Katsuhei; Iwasaki, Shin; Sakurai, Kiyoshi; Ikeda, Yujiro; Nakagawa, Tsuneo.

    1992-03-01

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d, n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form. (author) 76 refs

  11. JENDL Dosimetry File

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Masaharu; Iguchi, Tetsuo [Tokyo Univ. (Japan). Faculty of Engineering; Kobayashi, Katsuhei [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Iwasaki, Shin [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sakurai, Kiyoshi; Ikeda, Yujior; Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1992-03-15

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d,n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form.

  12. Fast neutron spectrometry and dosimetry

    International Nuclear Information System (INIS)

    Blaize, S.; Ailloud, J.; Mariani, J.; Millot, J.P.

    1958-01-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author) [fr

  13. Thermoelectric neutron dosimetry: a short introduction

    International Nuclear Information System (INIS)

    Mathieu, F.; Meier, R.; Debrue, J.; Leonard, F.; Schubert, W.

    1977-01-01

    The paper gives a short introduction and state-of-the-art account of an unconventional, non destructive neutron dosimetry method based on monitoring the neutron fluence dependent changes of the thermoelectric properties of base metals and alloys. The basic principles are exposed and illustrated with experimental data obtained during an exploratory irradiation in the BR2 reactor

  14. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Directory of Open Access Journals (Sweden)

    Hu J.-P.

    2016-01-01

    Full Text Available Radiation dosimetry for Neutron Capture Therapy (NCT has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR. In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1 in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2 out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3 beam shutter upgrade to reduce strayed neutrons and gamma dose, (4 beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5 beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates to reduce prompt gamma and fast neutron doses, (6 sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7 holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4–7

  15. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J. P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Holden, N. E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Reciniello, R. N.

    2014-05-23

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7

  16. Neutron dosimetry in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Fairchild, R.G.; Miola, U.J.; Ettinger, K.V.

    1981-01-01

    The recent development of various borated compounds and the utilization of one of these (Na 2 B 12 H 11 SH) to treat brain tumors in clinical studies in Japan has renewed interest in neutron capture therapy. In these procedures thermal neutrons interact with 10 B in boron containing cells through the 10 B(n,α) 7 Li reaction producing charged particles with a maximum range of approx. 10μm in tissue. Borated analogs of chlorpromazine, porphyrin, thiouracil and deoxyuridine promise improved tumor uptake and blood clearance. The therapy beam from the Medical Research Reactor in Brookhaven contains neutrons from a modified and filtered fission spectrum and dosimetric consequences of the use of the above mentioned compounds in conjunction with thermal and epithermal fluxes are discussed in the paper. One of the important problems of radiation dosimetry in capture therapy is determination of the flux profile and, hence, the dose profile in the brain. This has been achieved by constructing a brain phantom made of TE plastic. The lyoluminescence technique provides a convenient way of monitoring the neutron flux distributions; the detectors for this purpose utilize 6 Li and 10 B compounds. Such compounds have been synthesized specially for the purpose of dosimetry of thermal and epithermal beams. In addition, standard lyoluminescent phosphors, like glutamine, could be used to determine the collisional component of the dose as well as the contribution of the 14 N(n,p) 14 C reaction. Measurements of thermal flux were compared with calculations and with measurements done with activation foils

  17. Recombination methods for boron neutron capture therapy dosimetry

    International Nuclear Information System (INIS)

    Golnik, N.; Tulik, P.; Zielczynski, M.

    2003-01-01

    The radiation effects of boron neutron capture therapy (BNCT) are associated with four-dose-compartment radiation field - boron dose (from 10 B(n,α) 7 Li) reaction), proton dose from 14 N(n,p) 14 C reaction, neutron dose (mainly fast and epithermal neutrons) and gamma-ray dose (external and from capture reaction 1 H(n,γ) 2 D). Because of this the relation between the absorbed dose and the biological effects is very complex and all the above mentioned absorbed dose components should be determined. From this point of view, the recombination chambers can be very useful instruments for characterization of the BNCT beams. They can be used for determination of gamma and high-LET dose components for the characterization of radiation quality of mixed radiation fields by recombination microdosimetric method (RMM). In present work, a graphite high-pressure recombination chamber filled with nitrogen, 10 BF 3 and tissue equivalent gas was used for studies on application of RMM for BNCT dosimetry. The use of these gases or their mixtures opens a possibility to design a recombination chamber for determination of the dose fractions due to gamma radiation, fast neutrons, neutron capture on nitrogen and high LET particles from (n, 10 B) reaction in simulated tissue with different content of 10 B. (author)

  18. Least squares analysis of fission neutron standard fields

    International Nuclear Information System (INIS)

    Griffin, P.J.; Williams, J.G.

    1997-01-01

    A least squares analysis of fission neutron standard fields has been performed using the latest dosimetry cross sections. Discrepant nuclear data are identified and adjusted spectra for 252 Cf spontaneous fission and 235 U thermal fission fields are presented

  19. Topics in radiation dosimetry radiation dosimetry

    CERN Document Server

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  20. Dosimetry of an accident in mixed field (neutrons, photons) using the spectrometry by electronic paramagnetic resonance(EPR); Dosimetrie d'accident en champ mixte (neutrons, photons) utilisant la spectrometrie par resonance paramagnetique electronique (RPE)

    Energy Technology Data Exchange (ETDEWEB)

    Herve, M.L

    2006-03-15

    In a radiological accident, the assessment of the dose received by the victim is relevant information for the therapeutic strategy. Two complementary dosimetric techniques based on physical means are used in routine practice in the laboratory: EPR spectroscopy performed on materials removed from the victim or gathered from the vicinity of the victim and Monte Carlo calculations. EPR dosimetry, has been used successfully several times in cases of photon or electron overexposures. Accidental exposure may also occur with a neutron component. The aim of this work is to investigate the potentiality of EPR dosimetry for mixed photon and neutron field exposure with different organic materials (ascorbic acid, sorbitol, glucose, galactose, fructose, mannose, lactose and sucrose). The influence of irradiation parameters (dose, dose rate, photon energy) and of environmental parameters (temperature of heating, light exposure) on the EPR signal amplitude was studied. To assess the neutron sensitivity, the materials were exposed to a mixed radiation field of experimental reactors with different neutron to photon ratios. The relative neutron sensitivity was found to range from 10% to 43% according to the materials. Prior knowledge of the ratio between the dose in samples measured by EPR spectrometry and organ or whole body dose obtained by calculations previously performed for these different configurations, makes it possible to give a first estimation of the dose received by the victim in a short delay. The second aim of this work is to provide data relevant for a quick assessment of the dose distribution in case of accidental overexposure based on EPR measurements performed on one or several points of the body. The study consists in determining by calculation the relation between the dose to the organs and whole body and the dose to specific points of the body, like teeth, bones or samples located in the pockets of victim clothes, for different external exposures corresponding

  1. Calibration of SSTR neutron dosimetry for TMI-2 applications

    International Nuclear Information System (INIS)

    Gold, R.; Ruddy, F.H.; Roberts, J.H.; Preston, C.C.; Ulseth, J.A.; McElroy, W.N.; Leitz, F.J.; Hayward, B.R.; Schmittroth, F.A.

    1982-01-01

    Application of neutron dosimetry for assessment of fuel distribution throughout the Three Mile Island-2 (TMI-2) reactor-core region and the primary-coolant system is advanced. Neutron dosimetry in the reactor cavity, i.e. the cavity between the pressure vessel and the biological shield, could provide data for the assessment of the core fuel distribution. A more immediate task entails locating and quantifying the amount of fuel debris in the ex-core primary coolant system; in the range of 1 to 1000 kg. Solid-state track-recorder (SSTR) neutron dosimetry is considered for such exploratory scoping experiments at TMI-2. The sensitivity of mica- 235 U (asymptotically thick) SSTR has been ascertained for such environments. It has been demonstrated that the SSTR method has adequate sensitivity to properly respond and detect fuel quantities of the order of 1 kg in the ex-core primary coolant system. 21 figures

  2. Review of unfolding methods for neutron flux dosimetry

    International Nuclear Information System (INIS)

    Stallmann, F.W.; Kam, F.B.K.

    1975-01-01

    The primary method in reactor dosimetry is the foil activation technique. To translate the activation measurements into neutron fluxes, a special data processing technique called unfolding is needed. Some general observations about the problems and the reliability of this approach to reactor dosimetry are presented. Current unfolding methods are reviewed. 12 references. (auth)

  3. Report on high energy neutron dosimetry workshop

    International Nuclear Information System (INIS)

    Alvar, K.R.; Gavron, A.

    1993-01-01

    The workshop was called to assess the performance of neutron dosimetry per the responses from ten DOE accelerator facilities to an Office of Energy Research questionnaire regarding implementation of a personnel dosimetry requirement in DRAFT DOE 5480.ACC, ''Safety of Accelerator Facilities''. The goals of the workshop were to assess the state of dosimetry at high energy accelerators and if such dosimetry requires improvement, to reach consensus on how to proceed with such improvements. There were 22 attendees, from DOE Programs and contract facilities, DOE, Office of Energy Research (ER), Office of Environmental Safety and Health (EH), Office of Fusion Energy, and the DOE high energy accelerator facilities. A list of attendees and the meeting agenda are attached. Copies of the presentations are also attached

  4. Semiconductor dosimetry system for gamma and neutron radiation

    International Nuclear Information System (INIS)

    Savic, Z.; Pavlovic, Z.

    1995-01-01

    The semiconductor dosimetry system for gamma and neutron radiation based on pMOS transistor and PIN diode is described. It is intended for tactical or accidental personal dosimetry. The production steps are given. The temperature, dose and time (fading) response are reported. Hardware and software requirements which are needed for obtaining the desired measurement error are pointed. (author)

  5. Verification of dosimetry cross sections above 10 MeV based on measurement of activation reaction rates in fission neutron field

    International Nuclear Information System (INIS)

    Odano, Naoteru; Miura, Toshimasa; Yamaji, Akio.

    1996-01-01

    To validate the dosimetry cross sections in fast neutron energy range, activation reaction rates were measured for 5 types of dosimetry cross sections which have sensitivity in the energy rage above 10 MeV utilizing JRR-4 reactor of JAERI. The measured reaction rates were compared with the calculations reaction rates by a continuous energy monte carlo code MVP. The calculated reaction rates were based on two dosimetry files, JENDL Dosimetry File and IRDF-90.2. (author)

  6. Neutron excitation function guide for reactor dosimetry

    International Nuclear Information System (INIS)

    Gritzay, O.; Vlasov, M.; Chervonna, L.; Klimova, N.; Kolota, G.; Zerkin, V.

    2002-01-01

    Neutron Excitation Function Guide for Reactor Dosimetry (NEFGRD) has been prepared in the Ukrainian Nuclear Data Center (UKRNDC) using ZVV 9.2 code for graphical data presentation. The data can be retrieved through Web or obtained on CD-ROM or as hard copy report. NEFGRD contains graphical and text information for 56 nuclides (81 dosimetry reactions). Each reaction is provided by the information part and several graphical function blocks (from one to nine). (author)

  7. Li-Ion Batteries for Forensic Neutron Dosimetry

    Science.gov (United States)

    2016-03-01

    Li-Ion Batteries for Forensic Neutron Dosimetry Distribution Statement A. Approved for public release, distribution is unlimited. March...ion batteries are the common technology for powering portable electronics. The nuclear reactions within the batteries are sensitive to neutrons. By...and chemical changes within the battery . These changes can be determined by mass spectrometry or gamma and beta spectroscopy of long-lived

  8. Neutron dosimetry using aqueous solutions of lithium acetate

    International Nuclear Information System (INIS)

    Rakovan, L.J.

    1996-01-01

    A thermal neutron dosimetry system using the 6 Li(n,α) 3 H reaction and liquid scintillation counting of tritium was developed. Lithium acetate was chosen to supply the 6 Li in the aqueous dosimetry solutions. Neutron irradiations were completed using The Ohio State University Research Reactor. After two sets of samples were irradiated, variables in the system such as the mass of lithium acetate in the solutions and the counting window of the liquid scintillation counter used to analyze the sample were chosen. The system was evaluated by completing two sets of 23 minute irradiations with the reactor at 500 kW, 50 kW, 5 kW, and one irradiation at 500 W. The samples irradiated at 500 W were below the threshold of the system, and could not be used. Prompt analysis was essential due to loss of detectable emissions in the dosimetry solutions over time. The thermal neutron fluences calculated with the data from the samples were compared to the fluences determined from gold wire irradiations. The fluence values differed at most by 6%. The fluence values calculated from the samples were consistently less than those determined from the gold wires

  9. Neutron dosimetry of the Little Boy device

    International Nuclear Information System (INIS)

    Pederson, R.A.; Plassmann, E.A.

    1984-01-01

    Neutron dose rates at several angular locations and at distances out to 0.5 mile have been measured during critical operation of the Little Boy replica. We used modified remmetes and thermoluminescent dosimetry techniques for the measurements. The present status of our analysis is presented including estimates of the neutron-dose-relaxation length in air and the variation of the neutron-to-gamma-ray dose ratio with distance from the replica. These results are preliminary and are subject to detector calibration measurements

  10. Helium production measurements for neutron dosimetry and damage correlations

    International Nuclear Information System (INIS)

    Farrar, H. IV; Lippincott, E.P.

    1978-01-01

    Helium accumulation fluence monitors (HAFM's), consisting of miniature vanadium capsules containing small, accurately-known amounts of 10 B or 6 Li, are being used routinely for neutron dosimetry measurements in breeder reactor environments. Additionally, solid wires of Al, Fe and Cu have been irradiated by 14.8-MeV neutrons from the d-T reaction, and measurements of the helium production along these wires have given detailed neutron fluence profiles. Additional materials with relatively high (n,α) cross sections are being tested in a wide variety of neutron environments to select HAFM sets that will provide spectral information by unfolding techniques. The mass spectrometric helium measurement technique has been demonstrated to produce results with better than 2% (1 sigma) absolute accuracy. Intercomparisons with other laboratories have demonstrated good correlations with radiometric and fission chamber dosimetry results

  11. Establishing personal dosimetry procedure using optically stimulated luminescence dosimeters in photon and mixed photon-neutron radiation fields

    International Nuclear Information System (INIS)

    Le Ngoc Thiem; Bui Duc Ky; Trinh Van Giap; Nguyen Huu Quyet; Ho Quang Tuan; Vu Manh Khoi; Chu Vu Long

    2017-01-01

    According to Vietnamese Law on Atomic Energy, personal dosimetry (PD) for radiation workers is required periodically in order to fulfil the national legal requirements on occupational radiation dose management. Since the radiation applications have become popular in Vietnamese society, the thermal luminescence dosimeters (TLDs) have been used as passive dosimeters for occupational monitoring in the nation. Together with the quick increase in radiation applications and the number of personnel working in radiation fields, the Optically Stimulated Luminescence Dosimeters (OSLDs) have been first introduced since 2015. This work presents the establishment of PD measuring procedure using OSLDs which are used for measuring photons and betas known as Inlight model 2 OSL (OSLDs-p,e) and for measuring mixed radiations of neutrons, photons and betas known as Inlight LDR model 2 (OSLDs-n,p,e). Such following features of OSLDs are investigated: detection limit, energy response, linearity, reproducibility, angular dependency and fading with both types of OSLDs-p,e and OSLDs-n,p,e. The result of an intercomparison in PD using OSLDs is also presented in the work. The research work also indicates that OSL dosimetry can be an alternative method applied in PD and possibly become one of the most popular personal dosimetry method in the future. (author)

  12. Energy dependence of fast neutron dosimetry using electrochemical etching

    International Nuclear Information System (INIS)

    Su, S.J.; Morgan, K.Z.

    1978-01-01

    Registration of fast-neutron induced recoil tracks by the electrochemical etching technique as applied to sensitive Lexan polycarbonate foils provides a simple and inexpensive means of fast neutron personnel dosimetry. The sensitivity (tracks/neutron) of recoil particle registration is given as a function of neutron energy. Neutrons of 7 Li (p,n) 7 Be, 3 T (d,n) 4 He and 9 B, respectively. Results are compared with other studies using other neutron sources and conventional etching method

  13. Fast neutron dosimetry. Progress report, July 1, 1979-June 30, 1980

    International Nuclear Information System (INIS)

    Attix, F.H.

    1980-01-01

    Progress is reported in: the development and testing of new gas mixtures more suitable for fast neutron dosimetry using the common A150-type Tissue-equivalent plastic ion chambers; comparison of photon doses determined with a graphite-walled proportional counter and with paired dosimeters irradiated by 14.8-MeV neutrons; a detector for the direct measurement of LET distributions from irradiation with fast neutrons; LET distributions from fast neutron irradiation of TE-plastic and graphite measured in a cylindrically symmetric geometry; progress in development of a tandem fast neutron and 60 Co gamma ray source irradiation facility; an approach to the correlation of cellular response with lineal energy; calculated and measured HTO atmospheric dispersion rates within meters of a release site; application of cavity theory to fast neutrons; and fast neutron dosimetry by thermally stimulated currents in Al 2 O 3

  14. Neutron spectrum determination of d(20)+Be source reaction by the dosimetry foils method

    Science.gov (United States)

    Stefanik, Milan; Bem, Pavel; Majerle, Mitja; Novak, Jan; Simeckova, Eva

    2017-11-01

    The cyclotron-based fast neutron generator with the thick beryllium target operated at the NPI Rez Fast Neutron Facility is primarily designed for the fast neutron production in the p+Be source reaction at 35 MeV. Besides the proton beam, the isochronous cyclotron U-120M at the NPI provides the deuterons in the energy range of 10-20 MeV. The experiments for neutron field investigation from the deuteron bombardment of thick beryllium target at 20 MeV were performed just recently. For the neutron spectrum measurement of the d(20)+Be source reaction, the dosimetry foils activation method was utilized. Neutron spectrum reconstruction from resulting reaction rates was performed using the SAND-II unfolding code and neutron cross-sections from the EAF-2010 nuclear data library. Obtained high-flux white neutron field from the d(20)+Be source is useful for the intensive irradiation experiments and cross-section data validation.

  15. Dose Determination using alanine detectors in a Mixed Neutron and Gamma Field for Boron Neutron Capture Therapy of Liver Malignancies

    DEFF Research Database (Denmark)

    Schmitz, T.; Blaickner, M.; Ziegner, M.

    2011-01-01

    Introduction Boron Neutron Capture Therapy for liver malignancies is being investigated at the University of Mainz. One important aim is the set-up of a reliable dosimetry system. Alanine dosimeters have previously been applied for dosimetry of mixed radiation fields in antiproton therapy, and ma...

  16. Neutron dosimetry. Environmental monitoring in a BWR type reactor

    International Nuclear Information System (INIS)

    Tavera D, L.; Camacho L, M.E.

    1991-01-01

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  17. Integral test of International Reactor Dosimetry and Fusion File with Li{sub 2}O assembly and DT neutron source at JAEA/FNS

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Satoshi, E-mail: sato.satoshi92@jaea.go.jp [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan); Kwon, Saerom; Ohta, Masayuki [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan); Ochiai, Kentaro [Japan Atomic Energy Agency, Rokkasho-mura, Kamikita-gun, Aomori-ken (Japan); Konno, Chikara [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan)

    2016-11-01

    In order to validate a new library of dosimetry cross section data, International Reactor Dosimetry and Fusion File release 1.0 (IRDFF 1.0), not only for DT neutrons but also for neutrons with energy of less than 14 MeV, we perform an integral test with a Li{sub 2}O rectangular assembly of 60.7 cm in thickness and a DT neutron source at JAEA/FNS. We place a lot of activation foils at depths of 10.1 cm and 30.4 cm for measurements of dosimetry reaction rates in small space along the central axis in the assembly, measure decay gamma-rays from the activation foils with high-purity Ge detectors after the DT neutron irradiation by the foil activation technique, and deduce a variety of dosimetry reaction rates. We calculate the reaction rates by using a Monte Carlo code MCNP5-1.40 and the nuclear data library ENDF/B-VII.1 with the IRDFF-v.1.05 as the response functions for the dosimetry reactions. The calculation results generally show good agreements with the measured ones, and it can be confirmed that most of the data in IRDFF-v.1.05 are valid for the neutron field in the Li{sub 2}O assembly with the DT neutrons.

  18. Development of a new software tool, based on ANN technology, in neutron spectrometry and dosimetry research

    International Nuclear Information System (INIS)

    Ortiz R, J.M.; Martinez B, M.R.; Vega C, H.R.

    2007-01-01

    Artificial Intelligence is a branch of study which enhances the capability of computers by giving them human-like intelligence. The brain architecture has been extensively studied and attempts have been made to emulate it as in the Artificial Neural Network technology. A large variety of neural network architectures have been developed and they have gained wide-spread popularity over the last few decades. Their application is considered as a substitute for many classical techniques that have been used for many years, as in the case of neutron spectrometry and dosimetry research areas. In previous works, a new approach called Robust Design of Artificial Neural network was applied to build an ANN topology capable to solve the neutron spectrometry and dosimetry problems within the Mat lab programming environment. In this work, the knowledge stored at Mat lab ANN's synaptic weights was extracted in order to develop for first time a customized software application based on ANN technology, which is proposed to be used in the neutron spectrometry and simultaneous dosimetry fields. (Author)

  19. Development of a new software tool, based on ANN technology, in neutron spectrometry and dosimetry research

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz R, J.M.; Martinez B, M.R.; Vega C, H.R. [Universidad Autonoma de Zacatecas, Av. Ramon Lopez Velarde 801, A.P. 336, 98000 Zacatecas (Mexico)

    2007-07-01

    Artificial Intelligence is a branch of study which enhances the capability of computers by giving them human-like intelligence. The brain architecture has been extensively studied and attempts have been made to emulate it as in the Artificial Neural Network technology. A large variety of neural network architectures have been developed and they have gained wide-spread popularity over the last few decades. Their application is considered as a substitute for many classical techniques that have been used for many years, as in the case of neutron spectrometry and dosimetry research areas. In previous works, a new approach called Robust Design of Artificial Neural network was applied to build an ANN topology capable to solve the neutron spectrometry and dosimetry problems within the Mat lab programming environment. In this work, the knowledge stored at Mat lab ANN's synaptic weights was extracted in order to develop for first time a customized software application based on ANN technology, which is proposed to be used in the neutron spectrometry and simultaneous dosimetry fields. (Author)

  20. Fast neutron dosimetry. Progress report, July 1, 1979-June 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Attix, F.H.

    1980-01-01

    Progress is reported in: the development and testing of new gas mixtures more suitable for fast neutron dosimetry using the common A150-type Tissue-equivalent plastic ion chambers; comparison of photon doses determined with a graphite-walled proportional counter and with paired dosimeters irradiated by 14.8-MeV neutrons; a detector for the direct measurement of LET distributions from irradiation with fast neutrons; LET distributions from fast neutron irradiation of TE-plastic and graphite measured in a cylindrically symmetric geometry; progress in development of a tandem fast neutron and /sup 60/Co gamma ray source irradiation facility; an approach to the correlation of cellular response with lineal energy; calculated and measured HTO atmospheric dispersion rates within meters of a release site; application of cavity theory to fast neutrons; and fast neutron dosimetry by thermally stimulated currents in Al/sub 2/O/sub 3/. (GHT)

  1. Neutron generator (HIRRAC) and dosimetry study.

    Science.gov (United States)

    Endo, S; Hoshi, M; Takada, J; Tauchi, H; Matsuura, S; Takeoka, S; Kitagawa, K; Suga, S; Komatsu, K

    1999-12-01

    Dosimetry studies have been made for neutrons from a neutron generator at Hiroshima University (HIRRAC) which is designed for radiobiological research. Neutrons in an energy range from 0.07 to 2.7 MeV are available for biological irradiations. The produced neutron energies were measured and evaluated by a 3He-gas proportional counter. Energy spread was made certain to be small enough for radiobiological studies. Dose evaluations were performed by two different methods, namely use of tissue equivalent paired ionization chambers and activation of method with indium foils. Moreover, energy deposition spectra in small targets of tissue equivalent materials, so-called lineal energy spectrum, were also measured and are discussed. Specifications for biological irradiation are presented in terms of monoenergetic beam conditions, dose rates and deposited energy spectra.

  2. Investigation of the response characteristics of OSL albedo neutron dosimeters in a 241AmBe reference neutron field

    Science.gov (United States)

    Liamsuwan, T.; Wonglee, S.; Channuie, J.; Esoa, J.; Monthonwattana, S.

    2017-06-01

    The objective of this work was to systematically investigate the response characteristics of optically stimulated luminescence Albedo neutron (OSLN) dosimeters to ensure reliable personal dosimetry service provided by Thailand Institute of Nuclear Technology (TINT). Several batches of InLight® OSLN dosimeters were irradiated in a reference neutron field generated by the in-house 241AmBe neutron irradiator. The OSL signals were typically measured 24 hours after irradiation using the InLight® Auto 200 Reader. Based on known values of delivered neutron dose equivalent, the reading correction factor to be used by the reader was evaluated. Subsequently, batch homogeneity, dose linearity, lower limit of detection and fading of the OSLN dosimeters were examined. Batch homogeneity was evaluated to be 0.12 ± 0.05. The neutron dose response exhibited a linear relationship (R2=0.9974) within the detectable neutron dose equivalent range under test (0.4-3 mSv). For this neutron field, the lower limit of detection was between 0.2 and 0.4 mSv. Over different post-irradiation storage times of up to 180 days, the readings fluctuated within ±5%. Personal dosimetry based on the investigated OSLN dosimeter is considered to be reliable under similar neutron exposure conditions, i.e. similar neutron energy spectra and dose equivalent values.

  3. Achievements in workplace neutron dosimetry in the last decade: Lessons learned from the EVIDOS project

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bolognese-Milsztajn, T.; Boschung, M.; Coeck, M.; Curzio, G.; D'Errico, F.; Fiechtner, A.; Lillhoek, J. E.; Lacoste, V.; Lindborg, L.; Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Vanhavere, F.

    2007-01-01

    The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters can be made in calibration facilities, but these can never replicate the conditions under which the dosemeter is used in the workplace. Consequently, it is necessary to assess their performance in the workplace, which requires the field in the workplace to be fully characterised in terms of the energy and direction dependence of the fluence. This paper presents an overview of developments in workplace neutron dosimetry but concentrates on the outcomes of the EVIDOS project, which has made significant advances in the characterisation of workplace fields and the analysis of dosemeter responses in those fields. (authors)

  4. High energy neutron dosimetry for the fusion program

    International Nuclear Information System (INIS)

    Barr, D.W.; Norris, A.E.

    1977-01-01

    Neutron dosimetry by the foil activation method offers a flexible technique for characterizing neutron spectra ranging from thermal energies to 30 MeV with the potential for extension to higher neutron energies as investigated by the Los Alamos Radiochemistry Group at the Los Alamos Meson Physics Facility and in the Apollo-Soyuz Test Project. The use of this method for the neutron flux description in thermal, resonance, and fission spectrum assemblies has been demonstrated. An extension of the method to environments involving thermonuclear processes was developed at Los Alamos in the early 1950's to characterize mixed fission-thermonuclear systems

  5. Artificial neural networks in neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Hernandez D, V.M.; Manzanares A, E.; Mercado, G.A.; Perales M, W.A.; Robles R, J.A. [Unidades Academicas de Estudios Nucleares, UAZ, A.P. 336, 98000 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Depto. de Ingenieria Nuclear, Universidad Politecnica de Madrid, (Spain)

    2005-07-01

    An artificial neural network has been designed to obtain the neutron doses using only the Bonner spheres spectrometer's count rates. Ambient, personal and effective neutron doses were included. 187 neutron spectra were utilized to calculate the Bonner count rates and the neutron doses. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. Re-binned spectra, UTA4 response matrix and fluence-to-dose coefficients were used to calculate the count rates in Bonner spheres spectrometer and the doses. Count rates were used as input and the respective doses were used as output during neural network training. Training and testing was carried out in Mat lab environment. The artificial neural network performance was evaluated using the {chi}{sup 2}- test, where the original and calculated doses were compared. The use of Artificial Neural Networks in neutron dosimetry is an alternative procedure that overcomes the drawbacks associated in this ill-conditioned problem. (Author)

  6. Artificial neural networks in neutron dosimetry

    International Nuclear Information System (INIS)

    Vega C, H.R.; Hernandez D, V.M.; Manzanares A, E.; Mercado, G.A.; Perales M, W.A.; Robles R, J.A.; Gallego, E.; Lorente, A.

    2005-01-01

    An artificial neural network has been designed to obtain the neutron doses using only the Bonner spheres spectrometer's count rates. Ambient, personal and effective neutron doses were included. 187 neutron spectra were utilized to calculate the Bonner count rates and the neutron doses. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. Re-binned spectra, UTA4 response matrix and fluence-to-dose coefficients were used to calculate the count rates in Bonner spheres spectrometer and the doses. Count rates were used as input and the respective doses were used as output during neural network training. Training and testing was carried out in Mat lab environment. The artificial neural network performance was evaluated using the χ 2 - test, where the original and calculated doses were compared. The use of Artificial Neural Networks in neutron dosimetry is an alternative procedure that overcomes the drawbacks associated in this ill-conditioned problem. (Author)

  7. Dating by fission track method: study of neutron dosimetry with natural uranium thin films

    International Nuclear Information System (INIS)

    Iunes, P.J.

    1990-06-01

    Fission track dating is described, focalizing the problem of the decay constant for spontaneous fission of 238 U and the use of neutron dosimetry in fission track analysis. Experimental procedures using thin films of natural uranium as neutron dosimeters and its results are presented. The author shows a intercomparison between different thin films and between the dosimetry with thin film and other dosimetries. (M.V.M.). 52 refs, 12 figs, 9 tabs

  8. Bench mark spectra for high-energy neutron dosimetry

    International Nuclear Information System (INIS)

    Dierckx, R.

    1986-01-01

    To monitor radiation damage experiments, activation detectors are commonly used. The precision of the results obtained by the multiple foil analysis is largely increased by the intercalibration in bench-mark spectra. This technique is already used in dosimetry measurements for fission reactors. To produce neutron spectra similar to fusion reactor and high-energy high-intensity neutron sources (d-Li or spallation), accelerators can be used. Some possible solutions as p-Be and d-D 2 O neutron sources, useful as bench-mark spectra are described. (author)

  9. Dosimetry intercomparisons between fast neutron radiotherapy facilities

    International Nuclear Information System (INIS)

    Almond, P.R.; Smith, A.R.; Smathers, J.B.; Otte, V.A.

    1975-01-01

    Neutron dosimetry intercomparisons have been made between M.D. Anderson Hospital and Tumor Institute, Naval Research Laboratory, University of Washington Hospital, and Hammersmith Hospital. The parameters that are measured during these visits are: tissue kerma in air, tissue dose at depth of dose maximum, depth dose, beam profiles, neutron/gamma ratios and photon calibrations of ionization chambers. A preliminary report of these intercomparisons will be given including a comparison of the calculation and statement of tumor doses for each institution

  10. A method for neutron dosimetry in ultrahigh flux environments

    International Nuclear Information System (INIS)

    Ougouag, A.M.; Wemple, C.A.; Rogers, J.W.

    1996-01-01

    A method for neutron dosimetry in ultrahigh flux environments is developed, and devices embodying it are proposed and simulated using a Monte Carlo code. The new approach no longer assumes a linear relationship between the fluence and the activity of the nuclides formed by irradiation. It accounts for depletion of the original ''foil'' material and for decay and depletion of the formed nuclides. In facilities where very high fluences are possible, the fluences inferred by activity measurements may be ambiguous. A method for resolving these ambiguities is also proposed and simulated. The new method and proposed devices should make possible the use of materials not traditionally considered desirable for neutron activation dosimetry

  11. Albedo neutron dosimetry in Germany: regulations and performance

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Zimbal, A.; Busch, F.; Jordan, M.; Eichelberger, A.; Engelhardt, J.; Martini, E.; Figel, M.; Haninger, T.; Frasch, G.; Guenther, K.; Seifert, R.; Rimpler, A.

    2014-01-01

    Personal neutron dosimetry has been performed in Germany using albedo dosemeters for >20 y. This paper describes the main principles, the national standards, regulations and recommendations, the quality management and the overall performance, giving some examples. (authors)

  12. Photon and fast neutron dosimetry using aluminium oxide thermoluminescence dosemeters in a pool-type research reactor

    International Nuclear Information System (INIS)

    Santos, J.P.; Marques, J.G.; Fernandes, A.C.; Osvay, M.

    2007-01-01

    Al 2 O 3 :Mg,Y thermoluminescence (TL) dosemeters were used to measure photon and fast neutron doses in the mixed radiation field of the Portuguese Research Reactor. The dosemeters were irradiated in core positions under a photon dose rate of the order of 10 4 Gy/h and a fast neutron flux in the range of 10 9 -10 11 n/cm 2 /s. In order to evaluate the ability of the TL dosemeters for mixed field dosimetry at the research reactor, the measurements were compared with results obtained via conventional methods. The agreement between the different methods is better than 13% for the determination of photon doses and within 5% for the determination of neutron fluxes in mixed fields

  13. A solution for neutron personal dosimetry in the absence of workplace spectrometry

    International Nuclear Information System (INIS)

    Hajek, M.; Cruz Suarez, R.

    2016-01-01

    In view of the widely varying energy spectra encountered in practical situations, accuracy of neutron dose assessment requires detailed knowledge of detector responses and workplace conditions to achieve an adequate level of protection. If the neutron spectrum should be a priori unknown and no measurement of the workplace spectrum is available, the 'Compendium of Neutron Spectra and Detector Responses for Radiation Protection Purposes' published in the International Atomic Energy Agency Technical Report Series offers a broad range of reference spectra that may be appropriate for many applications. The proposed approach applies a correction factor based on the ratio of 'personal dose equivalent indices' for a particular workplace spectrum and a reference field used for calibration of the dosemeter response. Amendments in the definition of operational quantities as well as introduction of new modalities that, for example, may be expected to give increased importance to high-energy neutrons necessitate frequent revision of the Compendium. Results from the European Radiation Dosimetry Group Intercomparison 2012 for neutron personal dosemeters provide evidence that workplace fields are insufficiently reflected. This is proposed to be considered as an improvement opportunity. (authors)

  14. Neutron spectrometry and dosimetry using NSDAAN

    International Nuclear Information System (INIS)

    Martinez B, M. R.; Vega C, H. R.; Ortiz R, J. M.

    2009-10-01

    The reconstruction of neutron spectra from count rates of a Bonner spheres spectrometric system is performed using various methods such as Monte Carlo methods, the parameterization and iterative methods. The weight of the Bonner spheres spectrometric system, the procedure for the reconstruction of the spectra, the need of an experienced user, the high consumer of time, the need of use a reconstruction code as the BUNKI, SAND, among others, and the resolution of the spectrum are some problems that this system presents. This has motivated the development of complementary procedures such as maximum entropy, genetic algorithms and artificial neural networks. In previous work, has reported a new method called robust design methodology of artificial neural networks, to construct various network topologies capable of solving the problems of neutron spectrometry and dosimetry, however, due to the newness of this technology, be noted that there are not tools to end-user that allow test and validate the designed networks. This paper presents a software for the neutron spectrometry and dosimetry, designed from the information extracted of an artificial neural network designed by robust design methodology of artificial neural networks. This tool has the following characteristics: was designed in a user graphical interface easy to use, requires not knowledge of neural networks or neutron spectrometry by the user; execution speed of the application; unlike the deconvolution codes are not required to select an initial spectrum for the spectrum reconstruction; as an additional element to this tool, besides the spectrum, the calculation is performed simultaneous to H(10), E, H p , s (10,θ) from just counting rates from a Bonner spheres spectrometric system. (author)

  15. Neutron spectrometry and dosimetry with ANNs

    International Nuclear Information System (INIS)

    Vega C, H. R.; Hernandez D, V. M.; Gallego, E.; Lorente, A.

    2009-10-01

    Artificial neural networks technology has been applied to unfold the neutron spectra and to calculate the effective dose, the ambient equivalent dose, and the personal dose equivalent for 252 Cf and 241 AmBe neutron sources. A Bonner sphere spectrometry with a 6 LiI(Eu) scintillator was utilized to measure the count rates of the spheres that were utilized as input in two artificial neural networks, one for spectrometry and another for dosimetry. Spectra and the ambient dose equivalent were also obtained with BUNKIUT code and the UTA4 response matrix. With both procedures spectra and ambient dose equivalent agrees in less than 10%. (author)

  16. Artificial neural networks in neutron dosimetry

    International Nuclear Information System (INIS)

    Vega-Carrillo, H. R.; Hernandez-Davila, V. M.; Manzanares-Acuna, E.; Mercado, G. A.; Gallego, E.; Lorente, A.; Perales-Munoz, W. A.; Robles-Rodriguez, J. A.

    2006-01-01

    An artificial neural network (ANN) has been designed to obtain neutron doses using only the count rates of a Bonner spheres spectrometer (BSS). Ambient, personal and effective neutron doses were included. One hundred and eighty-one neutron spectra were utilised to calculate the Bonner count rates and the neutron doses. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. Re-binned spectra, UTA4 response matrix and fluence-to-dose coefficients were used to calculate the count rates in the BSS and the doses. Count rates were used as input and the respective doses were used as output during neural network training. Training and testing were carried out in the MATLAB R environment. The impact of uncertainties in BSS count rates upon the dose quantities calculated with the ANN was investigated by modifying by ±5% the BSS count rates used in the training set. The use of ANNs in neutron dosimetry is an alternative procedure that overcomes the drawbacks associated with this ill-conditioned problem. (authors)

  17. The Efficiency of the BC-720 Scintillator in a High-Energy (20--800 MeV) Accelerator Neutron Field

    Energy Technology Data Exchange (ETDEWEB)

    Miles, Leslie H. [Univ. of Missouri, Columbia, MO (United States)

    2005-12-01

    High-energy neutron doses (>20 MeV) are of little importance to most radiation workers. However, space and flight crews, and people working around medical and scientific accelerators receive over half of their radiation dose from high-energy neutrons. Unfortunately, neutrons are difficult to measure, and no suitable dosimetry has yet been developed to measure this radiation. In this paper, basic high-energy neutron interactions, characteristics of high-energy neutron environments, present neutron dosimetry, and quantities used in neutron dosimetry are discussed before looking into the potential of the BC-720 scintillator to improve dosimetry. This research utilized 800 MeV protons impinging upon the WNR Facility spallation neutron source at Los Alamos National Laboratory. Time-of-flight methods and a U-238 Fission Chamber were used to aid evaluation of the efficiency of the BC-720. Results showed that the efficiency is finite over the 20–650 MeV energy region studied, although it decreases by a factor of ten between 40 and 100 MeV. This limits the use of this dosimeter to measure doses at sitespecific locations. It also encourages modifications to use this dosimeter for any unknown neutron field. As such, this dosimeter has the potential for a small, lightweight, real-time dose measurement, which could impact neutron dosimetry in all high-energy neutron environments.

  18. The Neutron Personal Dosimetry Service of the Centre for Radiation, Chemical and Environmental Hazards, PHE-UK

    International Nuclear Information System (INIS)

    Campo Blanco, X.

    2015-01-01

    The Centre for Radiation, Chemical and Environmental Hazards (CRCEH), that belongs to Public Health England (PHE), hosts the official Neutron Personal Dosimetry Service of the United Kingdom. They use etched-track detectors, made of a material called PADC (poly-allyl diglycol carbonate), to determinate de neutron personal dose. A two weeks visit has been made to this center, in order to learn about the facilities, the methods employed and the legislative framework of the Neutron Personal Dosimetry Service. In this work the main results of this visits are shown, which are interesting for the future development of an official neutron personal dosimetry service in Spain.

  19. Neutron Reference Benchmark Field Specifications: ACRR Polyethylene-Lead-Graphite (PLG) Bucket Environment (ACRR-PLG-CC-32-CL).

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Richard Manuel [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Parm, Edward J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Griffin, Patrick J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Vehar, David W. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity with the Polyethylene-Lead-Graphite (PLG) bucket, reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 37 integral dosimetry measurements in the neutron field are reported.

  20. Research activities on dosimetry for high energy neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Yasuhiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    The external dosimetry research group of JAERI has been calculating dose conversion coefficients for high-energy radiations using particle transport simulation codes. The group has also been developing radiation dose measurement techniques for high-energy neutrons in collaboration with some university groups. (author)

  1. The determination of the thermal neutron and gamma fluxes at the Maryland University Training Reactor using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Karceski, Jeffrey David; Ebert, David D.; Munno, Frank J.

    1988-01-01

    Determination of the dose received by a material in a mixed gamma and neutron field is of paramount concern to any research reactor owner. This dose can be separated into three distinguishable parts using standard thermoluminescent dosimetry (TLD) responses: 1) thermal neutron dose, 2) fission gamma dose, and 3) fission product gamma dose. For the Maryland University Training Reactor (MUTR), these respective fluences were determined for each of the associated experimental facilities. Quantifying the magnitude of the gamma and thermal neutron exposures at various reactor power levels was accomplished using Li-6F and Li-7F TLDs, respectively. These two types of dosimetry were chosen given the following considerations: 1) there is no existing standard established for fluence determination in a mixed field, 2) the LiF TLDs have a wide range of sensitivity to radiation, from 0.01 mR to 10,000 R, and 3) LiF TLDs are easy to read given the proper equipment. Standardization of the gamma/neutron doses was accomplished using the 500,000 Rad/hr Co-60 gamma source also located at the University of Maryland. (author)

  2. A report on the fourth symposium on neutron dosimetry, 1st - 5th June 1981, G.S.F. [Gesellschaft fuer Strahlen und Umweltforschung] Munich - Neuherberg

    International Nuclear Information System (INIS)

    Harvey, J.R.

    1982-01-01

    At this international conference, papers were presented on neutron dosimetry applied to the fields of radiotherapy, radiobiology and radiological protection. Papers relating to: quantities and units, radiotherapy, microdosimetry, radiobiology, quality factors, doses in nuclear power stations, instrumentation, sources and fields are discussed. It is concluded that there is a growing awareness of the importance of neutron dosimetry, particularly in the USA. A paper presented by the author, describing the present status of a proposed international filtered team project is given as an Appendix in the form in which it will appear in the Proceedings. (author)

  3. Neutron dosimetry using optically stimulated luminescence

    International Nuclear Information System (INIS)

    Miller, S.D.; Eschbach, P.A.

    1991-06-01

    The addition of thermoluminescent (TL) materials within hydrogenous matrices to detect neutron-induced proton recoils for radiation dosimetry is a well-known concept. Previous attempts to implement this technique have met with limited success, primarily due to the high temperatures required for TL readout and the low melting temperatures of hydrogen-rich plastics. Research in recent years at Pacific Northwest laboratories (PNL) has produced a new Optically Stimulated Luminescence (OSL) technique known as the Cooled Optically Stimulated Luminescence (COSL) that offers, for the first time, the capability of performing extremely sensitive radiation dosimetry at low temperatures. In addition to its extreme sensitivity, the COSL technique offers multiple readout capability, limited fading in a one-year period, and the capability of analyzing single grains within a hydrogenous matrix. 4 refs., 10 figs

  4. The DS86 neutron dosimetry enigma: Some missing pieces to the puzzle

    International Nuclear Information System (INIS)

    Gold, R.

    1994-01-01

    International programs have been conducted over the last four decades to quantify the exposure of atom bomb survivors from Hiroshima and Nagasaki. Unfortunately, the quest for accurate gamma-ray and neutron exposure doses of atom bomb survivors has proven illusive. Efforts in the most recent of these programs, designated as Dosimetry System 1986 (DS86), have revealed a serious and persistent discrepancy between neutron transport calculations and thermal neutron activation measurements at the Hiroshima site, which will be called the DS86 neutron dosimetry enigma. It is established that this enigma is a complex puzzle that precludes simple solutions. This conclusion is deduced through the identification of a number of missing pieces to the puzzle. Implications and conclusions that can be inferred from these missing puzzle pieces are advanced

  5. SEVENTH DOE WORKSHOP ON PERSONNEL NEUTRON DOSIMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Vallario, E J

    1978-10-24

    This workshop was the seventh of a series and was held on October 23-24. 1978, at the Central Electricity Generating Board, HQ, London, England. Typically~ attendees at the Workshop were concerned with one of three activities: studying and refining existing techniques in an attempt to quantify already-known parameters with greater precision, looking for ways to apply existing neutron dosirr:etry techniques to a specific local problem, identifying the needs and weaknesses of existing systems, with the goal of improving and passibly simplifying field measurements. The types of neutron dosimetry techniques discussed by participants included albedo dosimeters, track etch, and TLD. One speaker reported on NTA film, noting that fading could be eliminated by drying the emulsion in dry nitrogen before field use. There were no reports on tissue equivalent proportional counters or activation analysis. One participant discussed a metal oxide silicon dosimeter. The need to develop a consistent standard terminology, as well as calibration sources and techniques, on both the national and international level was evident. The need for standardization is particularly acute in the U.S. Techniques for evaluating dosimeter response in the field should he standardized, since several different instruments with widely different response characteristics are currently being used. The choice of instruments is often parochial. Also. the type and use of phantoms should be standardized. Neutron dose assignment is significantly affected by the position of the dosimeter on the body. for example, a typical albedo dosimeter may give differences of up to 20% depending on whether it is worn on the belt or chest. Larger errors are encountered with front-to-back (angular} orientation. 1n an attempt to minimize such errors~ at least two European facilities are using neutron dosimeter belts, which provide dosimeters both in front and in back of the wearer. The gamma-to-neutron ratio around nuclear power

  6. Cross sections required for FMIT dosimetry

    International Nuclear Information System (INIS)

    Gold, R.; McElroy, W.N.; Lippincott, E.P.; Mann, F.M.; Oberg, D.L.; Roberts, J.H.; Ruddy, F.H.

    1980-01-01

    The Fusion Materials Irradiation Test (FMIT) facility, currently under construction, is designed to produce a high flux of high energy neutrons for irradiation effects experiments on fusion reactor materials. Characterization of the flux-fluence-spectrum in this rapidly varying neutron field requires adaptation and extension of currently available dosimetry techniques. This characterization will be carried out by a combination of active, passive, and calculational dosimetry. The goal is to provide the experimenter with accurate neutron flux-fluence-spectra at all positions in the test cell. Plans have been completed for a number of experimental dosimetry stations and provision for these facilities has been incorporated into the FMIT design. Overall needs of the FMIT irradiation damage program delineate goal accuracies for dosimetry that, in turn, create new requirements for high energy neutron cross section data. Recommendations based on these needs have been derived for required cross section data and accuracies

  7. Retrospective assessment of personnel neutron dosimetry for workers at the Hanford Site

    International Nuclear Information System (INIS)

    Fix, J.J.; Wilson, R.H.; Baumgartner, W.B.

    1996-09-01

    This report was prepared to examine the specific issue of the potential for unrecorded neutron dose for Hanford workers, particularly in comparison with the recorded whole body (neutron plus photon) dose. During the past several years, historical personnel dosimetry practices at Hanford have been documented in several technical reports. This documentation provides a detailed history of the technology, radiation fields, and administrative practices used to measure and record dose for Hanford workers. Importantly, documentation has been prepared by personnel whose collective experience spans nearly the entire history of Hanford operations beginning in the mid-1940s. Evaluations of selected Hanford radiation dose records have been conducted along with statistical profiles of the recorded dose data. The history of Hanford personnel dosimetry is complex, spanning substantial evolution in radiation protection technology, concepts, and standards. Epidemiologic assessments of Hanford worker mortality and radiation dose data were initiated in the early 1960s. In recent years, Hanford data have been included in combined analyses of worker cohorts from several Department of Energy (DOE) sites and from several countries through the International Agency for Research on Cancer (IARC). Hanford data have also been included in the DOE Comprehensive Epidemiologic Data Resource (CEDR). In the analysis of Hanford, and other site data, the question of comparability of recorded dose through time and across the respective sites has arisen. DOE formed a dosimetry working group composed of dosimetrists and epidemiologists to evaluate data and documentation requirements of CEDR. This working group included in its recommendations the high priority for documentation of site-specific radiation dosimetry practices used to measure and record worker dose by the respective DOE sites

  8. Neutron dosimetry using proportional counters with tissue equivalent walls

    International Nuclear Information System (INIS)

    Kerviller, H. de

    1965-01-01

    The author reminds the calculation method of the neutron absorbed dose in a material and deduce of it the conditions what this material have to fill to be equivalent to biological tissues. Various proportional counters are mode with walls in new tissue equivalent material and filled with various gases. The multiplication factor and neutron energy response of these counters are investigated and compared with those obtained with ethylene lined polyethylene counters. The conditions of working of such proportional counters for neutron dosimetry in energy range 10 -2 to 15 MeV are specified. (author) [fr

  9. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kosunen, A

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?){sup water} {sub air}, in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in {sup 60}Co gamma beams. In photon beam dosimetry (S I ?){sup water} {sub air} can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation

  10. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    International Nuclear Information System (INIS)

    Kosunen, A.

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?) water air , in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in 60 Co gamma beams. In photon beam dosimetry (S I ?) water air can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation). To improve the accuracy

  11. Personal dosimetry and area monitoring for neutrons and radon in workplaces

    International Nuclear Information System (INIS)

    Tommasino, L.

    2001-01-01

    The first successful applications of damage track detectors in radiation protection have been made in the early 1970s in personal dosimetry of neutrons, radon and its progenies. Most of the scientists actively engaged in the solution of the complex problem of personal neutron dosimetry by damage track detectors-SSNTD, have attempted to develop individual radon monitoring for exposure in mines by using the same SSNTDs. In late 1970s and the early 1980s, new radon monitoring devices based on SSNTDs have been developed to measure radon in soil, mainly for applications in uranium prospecting or more generally in earth sciences. Most of the radon monitors, developed since then for completely different applications in mind, have been used later for large scale survey of indoor radon. With the current implementation within Europe of the European Union Directive 96/29, applications of damage track detectors will increase drastically, specially for the assessment of the exposure of the workers to natural sources of radiation. In this case, the early work on personal neutron/radon dosimetry, is highly valuable to tackle these new problems of individual monitoring

  12. Neutron dosimetry using electrochemical etching

    International Nuclear Information System (INIS)

    Su, S.J.; Stillwagon, G.B.; Morgan, K.Z.

    1977-01-01

    Registration of α-tracks and fast-neutron-induced recoils tracks by the electrochemical etching technique as applied to sensitive polymer foils (e.g., polycarbonate) provides a simple, sensitive and inexpensive means of fast neutron personnel dosimetry as well as a valuable research tool for microdosimetry. When tracks were amplified by our electrochemical technique and the etching results compared with conventional etching technique a striking difference was noted. The electrochemically etched tracks were of much larger diameter (approx. 100 μm) and gave superior contrast. Two optical devices--the transparency projector and microfiche reader--were adapted to facilitate counting of the tracks appearing on our polycarbonate foils. The projector produced a magnification of 14X for a screen to projector distance of 5.0 meter and read's magnification was 50X. A Poisson distribution was determined for the number of tracks located in a particular area of the foil and experimentally verified by random counting of quarter sections of the microfiche reader screen. Finally, in an effort to determine dose equivalent (rem), a conversion factor is being determined by finding the sensitivity response (tracks/neutron) of recoil particle induced tracks as a function of monoenergetic fast neutrons and comparing results with those obtained by others

  13. Personnel neutron dose assessment upgrade: Volume 2, Field neutron spectrometer for health physics applications

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Reece, W.D.; Miller, S.D.

    1988-07-01

    Both the (ICRP) and the (NCPR) have recommended an increase in neutron quality factors and the adoption of effective dose equivalent methods. The series of reports entitled Personnel Neutron Dose Assessment Upgrade (PNL-6620) addresses these changes. Volume 1 in this series of reports (Personnel Neutron Dosimetry Assessment) provided guidance on the characteristics, use, and calibration of personnel neutron dosimeters in order to meet the new recommendations. This report, Volume 2: Field Neutron Spectrometer for Health Physics Applications describes the development of a portable field spectrometer which can be set up for use in a few minutes by a single person. The field spectrometer described herein represents a significant advance in improving the accuracy of neutron dose assessment. It permits an immediate analysis of the energy spectral distribution associated with the radiation from which neutron quality factor can be determined. It is now possible to depart from the use of maximum Q by determining and realistically applying a lower Q based on spectral data. The field spectrometer is made up of two modules: a detector module with built-in electronics and an analysis module with a IBM PC/reg sign/-compatible computer to control the data acquisition and analysis of data in the field. The unit is simple enough to allow the operator to perform spectral measurements with minimal training. The instrument is intended for use in steady-state radiation fields with neutrons energies covering the fission spectrum range. The prototype field spectrometer has been field tested in plutonium processing facilities, and has been proven to operate satisfactorily. The prototype field spectrometer uses a 3 He proportional counter to measure the neutron energy spectrum between 50 keV and 5 MeV and a tissue equivalent proportional counter (TEPC) to measure absorbed neutron dose

  14. Interactive and automated systems for nuclear track measurements with applications to fast neutron dosimetry

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; McNeece, J.P.; Preston, C.C.; Ruddy, F.H.

    1983-12-01

    Interactive and automatic track measuring systems have been developed primarily for fast neutron dosimetry in and around reactors. The interactive system is used for proton recoil measurements in nuclear research emulsions and the automatic systems for counting fission fragment tracks in Muscovite mica. The status of these systems, along with illustrative applications, are presented, particularly with regard to their relationship to neutron personnel dosimetry. 16 references, 12 figures

  15. Special methods used in neutron dosimetry

    International Nuclear Information System (INIS)

    Mas, P.

    1975-01-01

    The methods used in radiation reactor dosimetry which do not depend on fission reaction nor foil activation are reviewed. These other techniques are especially the following: the different types of self-powered detectors, with fast or slow response, their characteristics of noise and temperature effect, their practical uses: the damage detectors, considering the variations of their physical properties (resistivity, density, ...) and their use for characterizing the neutron spectra; the little loop with circulating fluids (air, nitrogen, helium, water) [fr

  16. Experimental possibilities and fast neutron dose map of the fast neutron fields at the RB reactor facility

    International Nuclear Information System (INIS)

    Sokcic-Kostic, M.; Pesic, M.; Antic, D.; Ninkovic, M.

    1993-01-01

    The RB is an unshielded, zero power nuclear facility with natural and enriched uranium fuel (2% and 80%) and D 2 O as moderator. It is possible to create different configurations of non-reflected and partially reflected critical systems and to make experiments in the fields of thermal neutrons. The fields of fast neutrons with 'softened' fission spectrum are made by modifying the system: modified experimental fuel channel EFC, coupled fast-thermal system in two configurations CFTS-1 and CFTS-2, coupled fast-thermal core HERBE. The intermediate and fast neutron absorbed doses in fast neutron fields are given. In first configuration of RB reactor it was almost impossible to perform dosimetric and other experiments. By creating these fields, with in our circumstances available fuel elements, the possibilities for different experiments are greatly improved. Now we can irradiate food samples, soil samples, electronic devices, study material properties, perform various dosimetry experiments, etc. (1 tab.)

  17. Neutron Reference Benchmark Field Specification: ACRR 44 Inch Lead-Boron (LB44) Bucket Environment (ACRR-LB44-CC-32-CL).

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Richard Manuel [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Parma, Edward J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Griffin, Patrick J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Vehar, David W. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity with the 44 inch Lead-Boron (LB44) bucket, reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

  18. Dosimetry; La dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  19. A feasibility study using radiochromic films for fast neutron 2D passive dosimetry

    International Nuclear Information System (INIS)

    Brady, Samuel L; Fallin, Brent; Gunasingha, Rathnayaka; Yoshizumi, Terry T; Howell, Calvin R; Crowell, Alexander S; Tonchev, Anton P; Dewhirst, Mark W

    2010-01-01

    The objective of this paper is threefold: (1) to establish sensitivity of XRQA and EBT radiochromic films to fast neutron exposure; (2) to develop a film response to radiation dose calibration curve and (3) to investigate a two-dimensional (2D) film dosimetry technique for use in establishing an experimental setup for a radiobiological irradiation of mice and to assess the dose to the mice in this setup. The films were exposed to a 10 MeV neutron beam via the 2 H(d,n) 3 He reaction. The XRQA film response was a factor of 1.39 greater than EBT film response to the 10 MeV neutron beam when exposed to a neutron dose of 165 cGy. A film response-to-soft tissue dose calibration function was established over a range of 0-10 Gy and had a goodness of fit of 0.9926 with the calibration data. The 2D film dosimetry technique estimated the neutron dose to the mice by measuring the dose using a mouse phantom and by placing a piece of film on the exterior of the experimental mouse setup. The film results were benchmarked using Monte Carlo and aluminum (Al) foil activation measurements. The radiochromic film, Monte Carlo and Al foil dose measurements were strongly correlated, and the film within the mouse phantom agreed to better than 7% of the externally mounted films. These results demonstrated the potential application of radiochromic films for passive 2D neutron dosimetry.

  20. Development of a transfer instrument for neutron dosimetry intercomparison

    International Nuclear Information System (INIS)

    Greene, D.; Miles, J.

    1974-01-01

    Comparisons are reported for fast neutron dosemeters which were designed to be transportable so as to enable intercomparisons between institutions using neutrons for radiotherapy or radiobiology. The systems considered are : 1) the ferrous sulphate dosemeter, 2) the lithium fluoride thermoluminescent dosemeter, 3) ionization chambers with various walls and gases. Work on photographic film dosimetry indicated that the system was not suitable and was not pursued. The sources used were 60 Co, the cyclotron at Hammersmith Hospital in London and 252 Cf

  1. Microscopic integral cross section measurements in the Be(d,n) neutron spectrum for applications in neutron dosimetry, radiation damage and the production of long-lived radionuclides

    International Nuclear Information System (INIS)

    Smith, D.L.; Meadows, J.W.; Greenwood, L.R.

    1990-01-01

    Integral neutron-reaction cross sections have been measured, relative to the U-238 neutron fission cross-section standard, for 27 reactions which are of contemporary interest in various nuclear applications (e.g., fast-neutron dosimetry, neutron radiation damage and the production of long-lived activities which affect nuclear waste disposal). The neutron radiation field employed in this study was produced by bombarding a thick Be-metal target with 7-MeV deuterons from an accelerator. The experimental results are reported along with detailed information on the associated measurement uncertainties and their correlations. These data are also compared with corresponding calculated values, based on contemporary knowledge of the differential cross sections and of the Be(d,n) neutron spectrum. Some conclusions are reached on the utility of this procedure for neutron-reaction data testing

  2. A European neutron dosimetry intercomparison project (ENDIP). Results and evaluation

    International Nuclear Information System (INIS)

    Broerse, J.J.; Burger, G.; Coppola, M.

    1978-01-01

    A total of twenty groups from nine countries participated in sessions of the European Neutron Dosimetry Intercomparison Project (ENDIP) which were held during 1975 at GSF, Munich-Neuherberg and TNO, Rijswijk. The data of all participants are collected, the analysis and evaluation of the results are given in the present report. Specific chapters deal with the experimental arrangements and monitoring results at GSF and TNO, characteristics of the dosimetry systems employed by the paticipating groups and the basic physical data and correction factors employed for the determination of kerma and absorbed dose. In general, the participants in ENDIP quote systematic uncertainties of 7 to 8% in the neutron and total kerma or absorbed dose, which are mainly attributed to inadequate knowledge of basic constants. The variations in the results obtained by different participants seem to be in accordance with the relative large systematic uncertainties quoted. In order to determine the influence of the use of different values for the physical parameters, the relative responses of the participants' dosimeters have also been compared. The variances of quoted kerma and dose values are of the same order of magnitude as those of instrument responses. This result indicates inconsistencies in experimental techniques employed by the participants for the determination of kerma and absorbed dose. A separate nonparametric analysis of the ENDIP results confirmed that there are considerable systematic differences. Recommendations for future studies on neutron dosimetry for biological and medical applications are given at the end of the report

  3. Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part II: conclusions and recommendations

    International Nuclear Information System (INIS)

    Schuhmacher, H.; Luszik-Bhadra, M.; Reginatto, M.; Bartlett, D.; Tanner, R.; Bolognese-Milsztajn, T.; Lacoste, V.; Boschung, M.; Fiechtner, A.; Coeck, M.; Vanhavere, F.; Curzio, G.; Errico d', F.; Kylloenen, J.-E.; Lindborg, L.

    2005-01-01

    Full text: The EVIDOS project, supported by the European Commission within the 5th Framework Programme, aims at evaluating state of the art dosimetry techniques in representative work-places of the nuclear industry. Seven European institutes with recognized expertise in radiation protection instruments and methods joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A particular task of the project was to develop methods to characterize the neutron component of mixed radiation fields at workplaces and to derive reference values of radiation protection quantities from energy and direction distributions of the neutron fluence. While other presentations at this workshop describe the methods developed and the instruments used, this presentation will summarize the main results, draw conclusions and discuss recommendations relevant to routine monitoring. The final results from the project include a catalogue with spectra and dosimetric data for 14 different workplace fields (boiling water reactor, pressurized water reactor, research reactor, fuel processing, storage of spent fuel), instruments and procedures to derive reference values for personal dose equivalent and other radiation protection quantities, and novel personal dosemeters for mixed radiation and results on their dosimetric and technical performance. A number of questions will be addressed in the presentation, including: which methods allow to determine H*(10) and H p (10) in complex mixed n/γ radiation fields with acceptable uncertainty?; what is the influence of the energy and direction distributions of neutrons on the ratios between H*(10), H p (10) and E?; how much do the readings of area monitors deviate from H*(10) and do they give conservative estimates of H p (10) and E?; how much do the readings of personal dosemeters deviate from H p (10) and do they give conservative estimates of E?; do new active (electronic

  4. Multisphere system neutron spectrometry applied to dosimetry for the personnel

    International Nuclear Information System (INIS)

    Allinei, P.G.

    1992-01-01

    Neutron dosimetry is a necessity that must be dealt with in order to ensure efficient monitoring of all personnel regarding radiology safety. Dosimetric variables are difficult to measure for they are dependent on complex functions evolving with the energy of neutrons, which forces us to determine their energetic distribution. We have chosen to use the multisphere system associated to an unfolding code in order to perform neutron spectrometry, our purpose being to determine these dosimetric variables. The initial stage consists in modifying a research code, the code SOHO, in order to adapt it to our needs. The resulting new version was subsequently tested and proven successful by means of computerized simulations. Afterwards, we used reference dosimetric and spectral beams to confirm the position results previously obtained. At the time of this test, the code SOHO yielded results coherent with the theoretical values, and even allowed the quantity of radiation diffused by the laboratory structures to be estimated. The final part of this study consists in applying the previously perfected technique to authentic situations. The results thus obtained are compared to those obtained by conventional methods in order to reveal the interest of neutron spectrometry used for dosimetry of the personnel

  5. Radiation dosimetry by neutron or X ray fluorescence activation of residual silver in ionographic emulsions

    International Nuclear Information System (INIS)

    Heilmann, C.

    1987-01-01

    A global measuring technique which is sensitive enough to detect small silver contents in films for dosimetry applications is presented. The applications studied are neutron dosimetry by measuring residual silver due to recoil protons in developed emulsions and high dose dosimetry by the detection of photolytic silver in fixed emulsions. An individual fast neutron dosimeter which can be used in radiation protection was developed, along with an automatic data analysis and readout system. Application of this technique to the measurement of high radiation doses (100 to 1 million Gy) via the measurement of photolytic silver in fixed, but undeveloped, emulsions confirms the usefulness of the method [fr

  6. Electrochemical etching amplification of low-let recoil particle tracks in polymers for fast neutron dosimetry

    International Nuclear Information System (INIS)

    Sohrabi, M.; Morgan, K.Z.

    1975-11-01

    An electrochemical etching method for the amplification of fast-neutron-induced recoil particle tracks in polymers was investigated. The technique gave superior results over those obtained by conventional etching methods especially when polycarbonate foils were used for recoil particle track amplification. Electrochemical etching systems capable of multi-foil processing were designed and constructed to demonstrate the feasibility of the techniques for large-scale neutron dosimetry. Electrochemical etching parameters were studied including the nature or type of the polymer foil used, foil thickness and its effect on etching time, the applied voltage and its frequency, the chemical composition, concentration, and temperature of the etchant, distance and angle between the electrodes, and the type of particles such as recoil particles including protons. Recoil particle track density, mean track diameter, and optical density as functions of the mentioned parameters were determined. Each parameter was found to have a distinct effect on the etching results in terms of the measured responses. Several new characteristics of this fast neutron dosimetry method were studied especially for personnel dosimetry using various radiation sources such as nuclear reactors, medical cyclotrons, and isotopic neutron sources. The dose range, neutron energy dependence, directional response, fading characteristics, neutron threshold energy, etc. were investigated

  7. Nevada test site neutron dosimetry-problems/solutions

    International Nuclear Information System (INIS)

    Sygitowicz, L.S.; Bastian, C.T.; Wells, I.J.; Koch, P.N.

    1991-01-01

    Historically, neutron dosimetry at the NTS was done using NTA film and albedo LiF TLD's. In 1987 the dosimeter type was changed from the albedo TLD based system to a CR-39 track etch based system modeled after the program developed by D. Hankins at LLNL. Routine issue and return is performed quarterly for selected personnel using bar-code readers at permanent locations. The capability exists for work site issue as-needed. Issue data are transmitted by telephone to a central computer where it is stored until the dosimeter is returned, processed and read, and the dose calculation is performed. Dose equivalent calculations are performed using LOTUS 123 and the results are printed as a hard copy record. The issue and dose information are hand-entered into the Dosimetry database. An application is currently being developed to automate this sequence

  8. JENDL dosimetry file 99 (JENDL/D-99)

    International Nuclear Information System (INIS)

    Kobayashi, Katsuhei; Iwasaki, Shin

    2002-01-01

    The JENDL Dosimetry File 99 (JENDL/D-99), which is a revised version of the JENDL Dosimetry File 91 (JENDL/D-91), has been compiled and released for the determination of neutron flux and energy spectra. This work was undertaken to remove the inconsistency between the cross sections and their covariances in JENDL/D-91 since the covariances were mainly taken from IRDF-85 although the cross sections were based on JENDL-3. Dosimetry cross sections have been evaluated for 67 reactions on 47 nuclides together with covariances. The cross sections for 34 major reactions and their covariances were simultaneously generated, and the remaining 33 reaction data were mainly taken from JENDL/D-91. Latest measurements were taken into account in the evaluation. The resultant evaluated data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-6 format. In order to confirm the reliability of the evaluated data, several integral tests have been carried out: comparisons with average cross sections measured in fission neutron fields, fast/thermal reactor spectra, DT neutron fields and Li(d,n) neutron fields. It was found from the comparisons that the cross sections calculated from JENDL/D-99 are generally in good agreement with the measured data. The contents of JENDL/D-99 and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form in the Appendix. (author)

  9. The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    Science.gov (United States)

    Schmitz, T; Bassler, N; Blaickner, M; Ziegner, M; Hsiao, M C; Liu, Y H; Koivunoro, H; Auterinen, I; Serén, T; Kotiluoto, P; Palmans, H; Sharpe, P; Langguth, P; Hampel, G

    2015-01-01

    The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a (60)Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes fluka and mcnp. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen & Olsen alanine response model. The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. The alanine detector can be used without

  10. BASACF, Integral Neutron Spectra Adjustment and Dosimetry

    International Nuclear Information System (INIS)

    Tichy, Milos

    1996-01-01

    1 - Description of program or function: Adjustment of a neutron spectrum based on integral detector measurements and calculation of an integral dosimetric quantity (integral flux, d.p.a., dose equivalent) and its variance. The program requires measured data (activities and their covariance matrix) and a priori information (spectrum, dosimetry cross sections, integral quantity conversion factor and their covariance matrices). All a priori covariance matrices can be read in from a file prepared by some other code or can be generated by means of three different methods (by subroutines included in the program). A subroutine which can normalize the a priori flux to measured data is also included. The program provides also adjusted dosimetry cross sections (with covariance matrix) so that it can be used for an adjustment of cross sections (or response functions of e.g. Bonner balls) by measurements in well-known neutron spectra. 2 - Method of solution: Bayesian theorem on conditional probability applied to linearized relation between activities, dosimetry cross sections and flux. All probability distributions are supposed to be normal and this supposition leads to minimizing of the same functional as least squares method (STAY'SL). This task is solved by a covariance filter method which avoids any matrix inversion and is numerically robust and stable. 3 - Restrictions on the complexity of the problem: This version can use 45 energy groups and 5 detectors and occupies 310 kB of main memory. This restriction can be modified according to available memory. The covariance matrix of activities is supposed diagonal. A solution is produced for any set of input data but in the case of non-consistent data, when measured activities do not match the a priori flux, the solution is not very meaningful

  11. Standard Practice for Application and Analysis of Nuclear Research Emulsions for Fast Neutron Dosimetry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 Nuclear Research Emulsions (NRE) have a long and illustrious history of applications in the physical sciences, earth sciences and biological sciences (1,2) . In the physical sciences, NRE experiments have led to many fundamental discoveries in such diverse disciplines as nuclear physics, cosmic ray physics and high energy physics. In the applied physical sciences, NRE have been used in neutron physics experiments in both fission and fusion reactor environments (3-6). Numerous NRE neutron experiments can be found in other applied disciplines, such as nuclear engineering, environmental monitoring and health physics. Given the breadth of NRE applications, there exist many textbooks and handbooks that provide considerable detail on the techniques used in the NRE method. As a consequence, this practice will be restricted to the application of the NRE method for neutron measurements in reactor physics and nuclear engineering with particular emphasis on neutron dosimetry in benchmark fields (see Matrix E706). 1...

  12. Direct ion storage dosimetry systems for photon, beta and neutron radiation with instant readout capabilities

    International Nuclear Information System (INIS)

    Wernli, C.; Kahilainen, J.

    2001-01-01

    The direct ion storage (DIS) dosemeter is a new type of electronic dosemeter from which the dose information for both H p (10) and H p (0.07) can be obtained instantly at the workplace by using an electronic reader unit. The number of readouts is unlimited and the stored information is not affected by the readout procedure. The accumulated dose can also be electronically reset by authorised personnel. The DIS dosemeter represents a potential alternative for replacing the existing film and thermoluminescence dosemeters (TLDs) used in occupational monitoring due to its ease of use and low operating costs. The standard version for normal photon and beta dosimetry, as well as a developmental version for neutron dosimetry, have been characterised in several field studies. Two new small size variations are also introduced including a contactless readout device and a militarised version optimised for field use. (author)

  13. Neutron dosimetry. Environmental monitoring in a BWR type reactor; Dosimetria de neutrones. Monitoreo ambiental en un reactor del tipo BWR

    Energy Technology Data Exchange (ETDEWEB)

    Tavera D, L; Camacho L, M E

    1991-01-15

    The measurements carried out on reactor dosimetry are applied mainly to the study on the effects of the radiation in 108 materials of the reactor; little is on the environmental dosimetry outside of the primary container of BWR reactors. In this work the application of a neutron spectrometer formed by plastic detectors of nuclear traces manufactured in the ININ, for the environmental monitoring in penetrations around the primary container of the unit I of the Laguna Verde central is presented. The neutron monitoring carries out with purposes of radiological protection, during the operational tests of the reactor. (Author)

  14. Differences in TLD 600 and TLD 700 glow curves derived from distict mixed gamma/neutron field irradiations

    International Nuclear Information System (INIS)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D.

    2013-01-01

    In Neutron Capture Therapy, a thermal neutron beam shall impinge on a specific nuclide, such as 10 B, to promote a nuclear reaction which releases the useful therapeutic energy. A nuclear reactor is usually used as the neutron source, and therefore field contaminants such as gamma and high energy neutrons are also present in the field. However, mixed field dosimetry still stands as a challenge in some cases, due to the difficulty to experimentally discriminate the dose from each field component. For the mixed field dosimetry, the International Commission on Radiation end Units (ICRU) recommends the use of detector pairs with different responses for each beam component. The TLD 600/700 pair meets this need, because these LiF detectors have different Li isotopes concentration, with distinct thermal neutron responses because 6 Li presents a much higher neutron capture cross section than does 7 Li for low energy neutrons. TLD 600 is 6 Li enriched while TLD 700 is 7 Li enriched. However, depending on the neutron spectrum presented in the mixed field, TLD 700 response to thermal neutrons cannot be disregarded. This work aims to study the difference in TLD 600 and TLD 700 glow curves when these TLDs are submitted to mixed fields of different energy spectra and components balance. The TLDs were irradiated in a pure gamma source, and in mixed fields from an AmBe sealed source and from the IPEN/MB-01 reactor. These TLDs were read and had their two main dosimetric regions analyzed to observe the differences in the glow curves of these TLDs in each irradiation. Field components discrimination was achieved through Monte Carlo simulations run with MCNP radiation transport code. (author)

  15. Reproducibility of TL measurements in a mixed field of thermal neutrons and photons

    International Nuclear Information System (INIS)

    Fernandes, A.C.; Goncalves, I.C.; Ferro Carvalho, A.; Santos, J.; Cardoso, J.; Santos, L.; Osvay, M.

    2002-01-01

    The reproducibility of measurements performed with GR-100 (LiF:Mg,Ti) from the Solid Dosimetric Detector and Method Laboratory (DML) China, GR-107 ( 7 LiF:Mg,Ti, DML), TLD-700H ( 7 LiF:Mg,Cu,P, Harshaw) and Al 2 O 3 :Mg,Y (Hungary) in photon and mixed photon-neutron fields was investigated. Mixed-field irradiations were performed in a thermal neutron field generated at a nuclear reactor. GR-100 sensitivity decreased after mixed-field irradiations, while no significant change was found for the other materials. Using GR-100 for the dosimetry of mixed and high-intensity fields requires careful procedures. (author)

  16. Fast Neutron Dosimetry Using CR-39 Nuclear Track Detector

    International Nuclear Information System (INIS)

    ZAKI, M.; ABDEL-NABY, A.; MORSY, A.

    2010-01-01

    Measurement of the neutron dose in and around the neutron sources is important for the purpose of personnel and environmental neutron dosimetry. In the present study, a method for the measurement of neutron dose using the UV-Vis spectra of CR-39 plastic track detector was investigated. A set of CR-39 plastic detectors was exposed to 252 Cf neutron source, which had the yield of 0.68x10 8 /s, and neutron dose equivalent rate 1m apart from the source is equal to 3.8 mrem/h. The samples were etched for 10 h in 6.25 N NaOH at 70 o C. The absorbance of the etched samples was measured using UV-visible spectrophotometer as a function of neutron dose. It was observed that there was a linear relationship between the optical absorption of these detectors and neutron dose. This means that the exposure dose of neutron can be determined by knowing the optical absorption of the sample. These results were compared with previous study. It was found that there was a matching and good agreement with their investigations.

  17. Reactor Dosimetry State of the Art 2008

    Science.gov (United States)

    Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan

    2009-08-01

    . Williams, A. P. Ribaric and T. Schnauber. Agile high-fidelity MCNP model development techniques for rapid mechanical design iteration / J. A. Kulesza.Extension of Raptor-M3G to r-8-z geometry for use in reactor dosimetry applications / M. A. Hunter, G. Longoni and S. L. Anderson. In vessel exposure distributions evaluated with MCNP5 for Atucha II / J. M. Longhino, H. Blaumann and G. Zamonsky. Atucha I nuclear power plant azimutal ex-vessel flux profile evaluation / J. M. Longhino ... [et al.]. UFTR thermal column characterization and redesign for maximized thermal flux / C. Polit and A. Haghighat. Activation counter using liquid light-guide for dosimetry of neutron burst / M. Hayashi ... [et al.]. Control rod reactivity curves for the annular core research reactor / K. R. DePriest ... [et al.]. Specification of irradiation conditions in VVER-440 surveillance positions / V. Kochkin ... [et al.]. Simulations of Mg-Ar ionisation and TE-TE ionisation chambers with MCNPX in a straightforward gamma and beta irradiation field / S. Nievaart ... [et al.]. The change of austenitic stainless steel elements content in the inner parts of VVER-440 reactor during operation / V. Smutný, J. Hep and P. Novosad. Fast neutron environmental spectrometry using disk activation / G. Lövestam ... [et al.]. Optimization of the neutron activation detector location scheme for VVER-lOOO ex-vessel dosimetry / V. N. Bukanov ... [et al.]. Irradiation conditions for surveillance specimens located into plane containers installed in the WWER-lOOO reactor of unit 2 of the South-Ukrainian NPP / O. V. Grytsenko. V. N. Bukanov and S. M. Pugach. Conformity between LRO mock-ups and VVERS NPP RPV neutron flux attenuation / S. Belousov. Kr. Ilieva and D. Kirilova. FLUOLE: a new relevant experiment for PWR pressure vessel surveillance / D. Beretz ... [et al.]. Transport of neutrons and photons through the iron and water layers / M. J. Kost'ál ... [et al.]. Condition evaluation of spent nuclear fuel assemblies

  18. Application of fission track detectors to californium-252 neutron dosimetry in tissue near the radiation source

    International Nuclear Information System (INIS)

    Oswald, R.A.; Lanzl, L.H.; Rozenfeld, M.

    1981-01-01

    Fission track detectors were applied to a unique problem in neutron dosimetry. Measurements of neutron doses were required at locations within a tumor of 1 cm diameter implanted on the back of a mouse and surrounded by a square array of four 252 Cf medical sources. Measurements made in a tissue-equivalent mouse phantom showed that the neutron dose rate to the center of the tumor was 2.18 rads mg -1 h -1 +- 8.4%. The spatial variation of neutron dose to the tumor ranged from 1.88 to 2.55 rads mg -1 h -1 . These measurements agree with calculated values of neutron dose to those locations in the phantom. Fission track detectors have been found to be a reliable tool for neutron dosimetry for geometries in which one wishes to know neutron dose values which may vary considerably over distances of 1 cm or less

  19. Application of fission track detectors to californium-252 neutron dosimetry in tissue near the radiation source

    International Nuclear Information System (INIS)

    Oswald, R.A.; Lanzl, L.H.; Rozenfeld, M.

    1981-01-01

    Fission track detectors were applied to a unique problem in neutron dosimetry. Measurements of neutron doses were required at locations within a tumor of 1 cm diameter implanted on the back of a mouse and surrounded by a square array of four 252 Cf medical sources. Measurements made in a tissue-equivalent mouse phantom showed that the neutron dose rate to the center of the tumor was 2.18 rads micrograms-1 h-1 +/- 8.4%. The spatial variation of neutron dose to the tumor ranged from 1.88 to 2.55 rads micrograms-1 h-1. These measurements agree with calculated values of neutron dose to those locations in the phantom. Fission track detectors have been found to be a reliable tool for neutron dosimetry for geometries in which one wishes to know neutron dose values which may vary considerably over distances of 1 cm or less

  20. Optimization of electret ionization chambers for dosimetry in mixed neutron-gamma fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Pretzsch, G.

    1984-01-01

    The properties of combination dosemeters consisting of two air-filled electret ionization chambers in mixed neutron-gamma fields have been investigated. The first chamber, polyethylene-walled, is sensitive to neutrons and gamma rays, the second, having walls of teflon, is sensitive to gamma rays only. The properties of the dosemeters are determined by the resulting errors and the measuring range. As both properties depend on the dimensions of the electret ionization chambers they have been taken into account in optimizing the dimensions. The results show that with the use of the dosemeters the effective dose equivalent in mixed neutron-gamma fields can be determined nearly independently of the spectra. The lower detection limit is less than 1 mSv and the maximum uncertainty of dose measurements about 12%. (author)

  1. Preliminary study about frequencies of unstable chromosome alterations induced by gamma beam and neutron-gamma mixed field

    International Nuclear Information System (INIS)

    Mendes, Mariana E.; Souza, Priscilla L.G.; Brandao, Jose Odinilson de C.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F.; Calixto, Merilane S.; Santos, Neide

    2011-01-01

    The estimate on approximate dose in exposed individual can be made through conventional cytogenetic analysis of dicentric, this technique has been used to support physical dosimetry. It is important to estimate the absorbed dose in case of accidents with the aim of developing an appropriate treatment and biological dosimetry can be very useful in case where the dosimetry is unavailable. Exposure to gamma and neutron radiation leads to the same biological effects such as chromosomal alterations and cancer. However, neutrons cause more genetic damage, such as mutation or more structural damage, such as chromosome alterations. The aim of research is to compare frequencies of unstable chromosome alterations induced by a gamma beam with those from neutron-gamma mixed field. Two blood samples were obtained from one healthy donor and irradiated at different sources. The first sample was exposed to mixed field neutron-gamma sources 241 AmBe at the Neutron Calibration Laboratory (NCL - CRCN/NE - PE - Brazil) and the second one was exposed to 137 Cs gamma rays at 137 Cs Laboratory (CRCN/NE - PE - Brazil), both exposures resulting in an absorbed dose of 0.66Gy. Mitotic metaphase cells were obtained by lymphocyte culture for chromosomal analysis and slides were stained with Giemsa 5%. These preliminary results showed a similarity in associated dicentrics frequency per cell (0.041 and 0.048) after 137 Cs and 241 AmBe sources irradiations, respectively. However, it was not observed centric rings frequency per cell (0.0 and 0.027). This study will be continue to verify the frequencies of unstable chromosome alterations induced by only gamma beam and neutron-gamma mixed field. (author)

  2. Preliminary study about frequencies of unstable chromosome alterations induced by gamma beam and neutron-gamma mixed field

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Mariana E.; Souza, Priscilla L.G.; Brandao, Jose Odinilson de C.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F. [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Calixto, Merilane S.; Santos, Neide [Universidade Federal de Pernanmbuco (CCB/UFPE), Recife, PE (Brazil). Centro de Ciencias Biologicas. Dept. de Genetica

    2011-07-01

    The estimate on approximate dose in exposed individual can be made through conventional cytogenetic analysis of dicentric, this technique has been used to support physical dosimetry. It is important to estimate the absorbed dose in case of accidents with the aim of developing an appropriate treatment and biological dosimetry can be very useful in case where the dosimetry is unavailable. Exposure to gamma and neutron radiation leads to the same biological effects such as chromosomal alterations and cancer. However, neutrons cause more genetic damage, such as mutation or more structural damage, such as chromosome alterations. The aim of research is to compare frequencies of unstable chromosome alterations induced by a gamma beam with those from neutron-gamma mixed field. Two blood samples were obtained from one healthy donor and irradiated at different sources. The first sample was exposed to mixed field neutron-gamma sources {sup 241}AmBe at the Neutron Calibration Laboratory (NCL - CRCN/NE - PE - Brazil) and the second one was exposed to {sup 137}Cs gamma rays at {sup 137}Cs Laboratory (CRCN/NE - PE - Brazil), both exposures resulting in an absorbed dose of 0.66Gy. Mitotic metaphase cells were obtained by lymphocyte culture for chromosomal analysis and slides were stained with Giemsa 5%. These preliminary results showed a similarity in associated dicentrics frequency per cell (0.041 and 0.048) after {sup 137}Cs and {sup 241}AmBe sources irradiations, respectively. However, it was not observed centric rings frequency per cell (0.0 and 0.027). This study will be continue to verify the frequencies of unstable chromosome alterations induced by only gamma beam and neutron-gamma mixed field. (author)

  3. Optimization of CR-39 for fast neutron dosimetry applications

    International Nuclear Information System (INIS)

    Vilela, E.; Fantuzzi, E.; Giacomelli, G.; Giorgini, M.; Morelli, B.; Patrizii, L.; Serra, P.; Togo, V.

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: 241 Am-Be, 252 Cf and 238 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose

  4. Boron dose determination for BNCT using Fricke and EPR dosimetry

    International Nuclear Information System (INIS)

    Wielopolski, L.; Ciesielski, B.

    1995-01-01

    In Boron Neutron Capture Therapy (BNCT) the dominant dose delivered to the tumor is due to α and 7 Li charged particles resulting from a neutron capture by 10 B and is referred to herein as the boron dose. Boron dose is directly attributable to the following two independent factors, one boron concentration and the neutron capture energy dependent cross section of boron, and two the energy spectrum of the neutrons that interact with boron. The neutron energy distribution at a given point is dictated by the incident neutron energy distribution, the depth in tissue, geometrical factors such as beam size and patient's dimensions. To account for these factors can be accommodated by using Monte Carlo theoretical simulations. However, in conventional experimental BNCT dosimetry, e.g., using TLDs or ionization chambers, it is only possible to estimate the boron dose. To overcome some of the limitations in the conventional dosimetry, modifications in ferrous sulfate dosimetry (Fricke) and Electron Paramagnetic Resonance (EPR) dosimetry in alanine, enable to measure specifically boron dose in a mixed gamma neutron radiation fields. The boron dose, in either of the dosimeters, is obtained as a difference between measurements with boronated and unboronated dosimeters. Since boron participates directly in the measurements, the boron dosimetry reflects the true contribution, integral of the neutron energy spectrum with boron cross section, of the boron dose to the total dose. Both methods are well established and used extensively in dosimetry, they are presented briefly here

  5. Fiscal year 1976 DT fusion neutron irradiations and dosimetry at the LLL rotating target neutron source

    International Nuclear Information System (INIS)

    MacLean, S.C.

    1977-01-01

    The DT fusion neutron irradiation of 319 samples during 19 irradiation periods (beam-on time of more than 1026 hours) is described. Experiments from 24 individuals representing 11 institutions are summarized. The numbers of the UCID dosimetry reports detailing each of the irradiations are given

  6. Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry

    International Nuclear Information System (INIS)

    Fiechtner, A.; Boschung, M.; Wernli, C.

    2007-01-01

    In the framework of the EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields) project, funded by the EC, measurements with PADC personal neutron dosemeters were carried out at several workplace fields of the nuclear industry and at simulated workplace fields. The measured personal neutron dose equivalents of the PADC personal neutron dosemeter are compared with values that were assessed within the EVIDOS project by other partners. The detection limits for different spectra types are given. In cases were the neutron dose was too low to be measured by the PADC personal neutron dosemeter, the response is estimated by convoluting the responses to monoenergetic neutrons with the dose energy distribution measured within EVIDOS. The advantages and limitations of the PADC personal neutron dosemeter are discussed. (authors)

  7. Neutron-photon mixed field dosimetry by TLD-700 glow curve analysis and its implementation in dose monitoring for Boron Neutron Capture Therapy (BNCT) treatments

    Energy Technology Data Exchange (ETDEWEB)

    Boggio, E. F.; Longhino, J. M. [Centro Atomico Bariloche, Departamento de Fisica de Reactores y Radiaciones / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina); Andres, P. A., E-mail: efboggio@cab.cnea.gov.ar [Centro Atomico Bariloche, Division Proteccion Radiologica / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina)

    2015-10-15

    BNCT is a cancerous cells selective, non-conventional radiotherapy modality to treat malignant tumors such as glioblastoma, melanoma and recurrent head and neck cancer. It consists of a two-step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope (Boron-10) with high slow neutron capture cross-section. In a second step, the patient is irradiated with neutrons, which are absorbed by the Boron-10 agent with the subsequently nuclear reaction B- 10(n,a)Li-7, thereby resulting in dose at cellular level due to the high-Let particles. The neutron fields suitable for BNCT are characterized by high neutron fluxes and low gamma dose. Determination of each component is not an easy task, especially when the volume of measurement is quite small or inaccessible for a miniature ionization chamber, for example. A method of measuring the photon and slow neutron dose(mainly by N-14 and B-10) from the glow curve (GC) analysis of a single {sup 7}LiF thermoluminescence detector is evaluated. This method was suggested by the group headed by Dr. Grazia Gambarini. The dosemeters used were TLD-600 ({sup 6}LiF:Mg,Ti with 95.6% {sup 6}Li) and TLD-700 ({sup 7}LiF:Mg,Ti with 99.9% {sup 7}LiF) from Harshaw. Photon dose measurement using the GC analysis method with TLD-700 in mixed fields requires the relation of the two main peaks of a TLD-600 GC shape obtained from an exposition to the same neutron field, and a photon calibrated GC with TLD-700. The requirements for slow neutron dose measurements are similar. In order to properly apply the GC analysis method at the Ra-6 Research Reactor BNCT facility, measurements were carried out in a standard water phantom, fully characterized on the BNCT beam by conventional techniques (activation detectors and paired ionization chambers technique). Next, the method was implemented in whole body dose monitoring of a patient undergoing a BNCT treatment, using a Bo MAb (Bottle Manikin Absorption) phantom

  8. Biological dosimetry studies for boron neutron capture therapy at the RA-1 research reactor facility

    International Nuclear Information System (INIS)

    Trivillin, Veronica A.; Heber, Elisa M.; Itoiz, Maria E.; Schwint, Amanda E.; Castillo, Jorge

    2004-01-01

    Initial physical dosimetry measurements have been completed using activation spectrometry and thermoluminescent dosimeters to characterize the BNCT facility developed at the RA-1 research reactor operated by the National Atomic Energy Commission in Buenos Aires. Biological dosimetry was performed employing the hamster cheek pouch oral cancer model previously validated for BNCT studies by our group. Results indicate that the RA-1 neutron source produces useful dose rates for BNCT studies but that some improvements in the initial configuration will be needed to optimize the spectrum for thermal-neutron BNCT research applications. (author)

  9. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  10. Final report for the 1st ex-vessel neutron dosimetry installations and evaluations for Kori unit 2 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 2 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 20 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 20.

  11. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Li, Nam Jin; Hong, Joon Wha

    2007-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  12. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  13. Final report for the 1st ex-vessel neutron dosimetry installation and evaluations for Kori unit 4 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 4 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 16 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 4 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 16.

  14. Fast-neutron dosimetry in the seed-irradiation facility, ASTRA reactor, Seibersdorf

    International Nuclear Information System (INIS)

    Ahnstroem, G.; Burtscher, A.; Casta, J.

    1967-01-01

    An important part of the co-ordinated programme on the neutron irradiation of seeds has been the construction of a fast-neutron irradiation facility for swimming-pool reactors. This facility was installed around 70 cm from the core in the ASTRA reactor swimming-pool at the end of December, 1966. Also, for this programme a pair of constant potential ionization chambers have been constructed at the Institute of Biochemistry, Stockholm University. These chambes are of the type described in the technical annex and are the same size as the seed-irradiation vials to be used in the seed-irradiation container (diam. =15 mm, length = 60 mm). Some preliminary dosimetry experiments were undertaken to test the irradiation facility and the ionization chambers, and to investigate the usefulness of the dosimetry instructions in the Technical Annex. The results of these experiments are discussed in this paper. 3 refs, 6 figs, 7 tabs

  15. The Bristol University neutron dosimetry system

    International Nuclear Information System (INIS)

    Worley, A.; Fews, A.P.; Henshaw, D.L.

    1987-01-01

    The neutron dosimetry system developed at Bristol is based on recording recoil proton tracks in conventionally etched PADC plastic using a fully automated image analysis system. Two features contribute to the achievement of a low dose threshold: high quality plastic is manufactured and undergoes extensive quality control tests prior to acceptance for use in dosimetry, and a readout system with high efficiency for rejecting background events is used. The principal dosemeter that has been developed consists of three orthogonal elements, each containing two 3 cm x 1 cm plastics on either side of a polyethylene radiator. On each plastic an area of 0.15 cm 2 is scanned giving a total active area of 0.90 cm 2 . Each plastic is coded for manual identification and for computer recognition. The track counts from the six plastics are added with different weightings to achieve a measure of dose which is independent of irradiation direction when worn on the body. The device has been calibrated using monoenergetic neutrons in the range 100 keV to 14.7 MeV at NPL, and using the recent CENDOS exposure. If the track counts are added without weighting, the device has a nominal response of 120 tracks cm -2 .mSv -1 and an energy threshold at 200 keV. Taken together with a background of 20 track cm -2 , a dose threshold of around 80μSv is implied. A simpler dosemeter, using a single plastic/radiator combination, may also be considered. If a 1 cm 2 device is used for normal incidence exposure, the dose threshold is calculated to be 25 μSv. (author)

  16. Practical neutron dosimetry at high energies

    International Nuclear Information System (INIS)

    McCaslin, J.B.; Thomas, R.H.

    1980-10-01

    Dosimetry at high energy particle accelerators is discussed with emphasis on physical measurements which define the radiation environment and provide an immutable basis for the derivation of any quantities subsequently required for risk evaluation. Results of inter-laboratory dosimetric comparisons are reviewed and it is concluded that a well-supported systematic program is needed which would make possible detailed evaluations and inter-comparisons of instruments and techniques in well characterized high energy radiation fields. High-energy dosimetry is so coupled with radiation transport that it is clear their study should proceed concurrently

  17. Applicability of thermoluminescent dosimeters in X-ray organ dose determination and in the dosimetry of systemic and boron neutron capture radiotherapy

    International Nuclear Information System (INIS)

    Aschan, C.

    1999-01-01

    The main detectors used for clinical dosimetry are ionisation chambers and semiconductors. Thermoluminescent (TL) dosimeters are also of interest because of their following advantages: (i) wide useful dose range, (ii) small physical size, (iii) no need for high voltage or cables, i.e. stand alone character, and (iv) tissue equivalence (LiF) for most radiation types. TL detectors can particularly be used for the absorbed dose measurements performed with the aim to investigate cases where dose prediction is difficult and not as part of a routine verification procedure. In this thesis, the applicability of TL detectors was studied in different clinical applications. Particularly, the major phenomena (e.g. energy dependence, sensitivity to high LET radiation, reproducibility) affecting on the precision and accuracy of TL detectors in the dose estimations were considered in this work. In organ dose determinations of diagnostic X-ray examinations, the TL detectors were found to be accurate within 5% (1 S.D.). For in viva studies using internal irradiation source, i.e. for systemic radiation therapy, a method for determining the absorbed doses to organs was introduced. The TL method developed was found to be able to estimate the absorbed doses to those critical organs near the body surface within 50%. In the mixed neutron-gamma field of boron neutron capture therapy (BNCT), TL detectors were used for gamma dose and neutron fluence measurements. They were found able to measure the neutron dose component with the accuracy of 16%, and therefore to be a useful addition to the activation foils in BNCT neutron dosimetry. The absorbed gamma doses can be measured with TL detectors within 20% in the mixed neutron-gamma field, which enables in viva measurements at BNCT beams with approximately the same accuracy. In this study, the uncertainties of TL dosimeters were found to be high but not essentially greater than those in other measurement techniques used for clinical dosimetry

  18. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    CERN Document Server

    Kumada, H; Matsumura, A; Nakagawa, Y; Nose, T; Torii, Y; Uchiyama, J; Yamamoto, K; Yamamoto, T

    2003-01-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is...

  19. Investigation of dose distribution in mixed neutron-gamma field of boron neutron capture therapy using N isopropylacrylamide gel

    Energy Technology Data Exchange (ETDEWEB)

    Bavarmegin, Elham; Sadremomtaz, Alireza [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Khalafi, Hossein; Kasesaz, Yaser [Dept. of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Khajeali, Azim [Medical Education Research Center, Tabriz (Iran, Islamic Republic of)

    2017-02-15

    Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the R2 maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

  20. Calibration of activation detectors in a monoenergetic neutron beam. Contribution to criticality dosimetry

    International Nuclear Information System (INIS)

    Massoutie, Martine.

    1981-05-01

    Activation detectors have been calibrated for critical dosimetry applications. Measurements are made using a monoenergetic neutron flux. 14 MeV neutrons obtained par (D-T) reaction are produced by 150 kV accelerator. Neutron flux determined by different methods leads us to obtain an accuracy better than 6%. The present dosimetric system (Activation Neutron Spectrometer - SNAC) gives few informations in the (10 keV - 2 MeV) energetic range. The system has been improved and modified so that SNAC detectors must be read out by gamma spectrometer [fr

  1. High energy dosimetry

    International Nuclear Information System (INIS)

    Ruhm, W.

    2010-01-01

    Full text: Currently, quantification of doses from high-energy radiation fields is a topical issue. This is so because high-energy neutrons play an important role for radiation exposure of air crew members and personnel outside the shielding of ion therapy facilities. In an effort to study air crew exposure from cosmic radiation in detail, two Bonner Sphere Spectrometers (BSSs) have recently been installed to measure secondary neutrons from cosmic radiation, one at the environmental research station 'Schneefernerhaus' at an altitude of 2650 m on the Zugspitze mountain, Germany, the other at the Koldewey station close to the North Pole on Spitsbergen. Based on the measured neutron fluence distributions and on fluence-to-dose conversion coefficients, mean ambient dose equivalent rate values of 75.0 ± 2.9 nSv/h and 8.7 ± 0.6 nSv/h were obtained for October 2008, respectively. Neutrons with energies above about 20 MeV contribute about 50% to dose, at 2650 m. Ambient dose equivalent rates measured by means of a standard rem counter and an extended rem counter at the Schneefernerhaus confirm this result. In order to study the response of state-of-the-art radiation instrumentation in such a high-energy radiation field, a benchmark exercise that included both measurements in and simulation of the stray neutron radiation field at the high-energy particle accelerator at GSI, Germany, were performed. This CONRAD (COordinated Network for RAdiation Dosimetry) project was funded by the European Commission, and the organizational framework was provided by the European Radiation Dosimetry Group, EURADOS. The Monte Carlo simulations of the radiation field and the experimental determination of the neutron spectra with various Bonner Sphere Spectrometers suggest the neutron fluence distributions to be very similar to those of secondary neutrons from cosmic radiation. The results of this intercomparison exercise in terms of ambient dose equivalent are also discussed

  2. Training of reverse propagation neural networks applied to neutron dosimetry

    International Nuclear Information System (INIS)

    Hernandez P, C. F.; Martinez B, M. R.; Leon P, A. A.; Espinoza G, J. G.; Castaneda M, V. H.; Solis S, L. O.; Castaneda M, R.; Ortiz R, M.; Vega C, H. R.; Mendez V, R.; Gallego, E.; De Sousa L, M. A.

    2016-10-01

    Neutron dosimetry is of great importance in radiation protection as aims to provide dosimetric quantities to assess the magnitude of detrimental health effects due to exposure of neutron radiation. To quantify detriment to health is necessary to evaluate the dose received by the occupationally exposed personnel using different detection systems called dosimeters, which have very dependent responses to the energy distribution of neutrons. The neutron detection is a much more complex problem than the detection of charged particles, since it does not carry an electric charge, does not cause direct ionization and has a greater penetration power giving the possibility of interacting with matter in a different way. Because of this, various neutron detection systems have been developed, among which the Bonner spheres spectrometric system stands out due to the advantages that possesses, such as a wide range of energy, high sensitivity and easy operation. However, once obtained the counting rates, the problem lies in the neutron spectrum deconvolution, necessary for the calculation of the doses, using different mathematical methods such as Monte Carlo, maximum entropy, iterative methods among others, which present various difficulties that have motivated the development of new technologies. Nowadays, methods based on artificial intelligence technologies are being used to perform neutron dosimetry, mainly using the theory of artificial neural networks. In these new methods the need for spectrum reconstruction can be eliminated for the calculation of the doses. In this work an artificial neural network or reverse propagation was trained for the calculation of 15 equivalent doses from the counting rates of the Bonner spheres spectrometric system using a set of 7 spheres, one of 2 spheres and two of a single sphere of different sizes, testing different error values until finding the most appropriate. The optimum network topology was obtained through the robust design

  3. Monte Carlo simulation of mixed neutron-gamma radiation fields and dosimetry devices

    International Nuclear Information System (INIS)

    Zhang, Guoqing

    2011-01-01

    Monte Carlo methods based on random sampling are widely used in different fields for the capability of solving problems with a large number of coupled degrees of freedom. In this work, Monte Carlos methods are successfully applied for the simulation of the mixed neutron-gamma field in an interim storage facility and neutron dosimeters of different types. Details are discussed in two parts: In the first part, the method of simulating an interim storage facility loaded with CASTORs is presented. The size of a CASTOR is rather large (several meters) and the CASTOR wall is very thick (tens of centimeters). Obtaining the results of dose rates outside a CASTOR with reasonable errors costs usually hours or even days. For the simulation of a large amount of CASTORs in an interim storage facility, it needs weeks or even months to finish a calculation. Variance reduction techniques were used to reduce the calculation time and to achieve reasonable relative errors. Source clones were applied to avoid unnecessary repeated calculations. In addition, the simulations were performed on a cluster system. With the calculation techniques discussed above, the efficiencies of calculations can be improved evidently. In the second part, the methods of simulating the response of neutron dosimeters are presented. An Alnor albedo dosimeter was modelled in MCNP, and it has been simulated in the facility to calculate the calibration factor to get the evaluated response to a Cf-252 source. The angular response of Makrofol detectors to fast neutrons has also been investigated. As a kind of SSNTD, Makrofol can detect fast neutrons by recording the neutron induced heavy charged recoils. To obtain the information of charged recoils, general-purpose Monte Carlo codes were used for transporting incident neutrons. The response of Makrofol to fast neutrons is dependent on several factors. Based on the parameters which affect the track revealing, the formation of visible tracks was determined. For

  4. Monte Carlo simulation of mixed neutron-gamma radiation fields and dosimetry devices

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Guoqing

    2011-12-22

    Monte Carlo methods based on random sampling are widely used in different fields for the capability of solving problems with a large number of coupled degrees of freedom. In this work, Monte Carlos methods are successfully applied for the simulation of the mixed neutron-gamma field in an interim storage facility and neutron dosimeters of different types. Details are discussed in two parts: In the first part, the method of simulating an interim storage facility loaded with CASTORs is presented. The size of a CASTOR is rather large (several meters) and the CASTOR wall is very thick (tens of centimeters). Obtaining the results of dose rates outside a CASTOR with reasonable errors costs usually hours or even days. For the simulation of a large amount of CASTORs in an interim storage facility, it needs weeks or even months to finish a calculation. Variance reduction techniques were used to reduce the calculation time and to achieve reasonable relative errors. Source clones were applied to avoid unnecessary repeated calculations. In addition, the simulations were performed on a cluster system. With the calculation techniques discussed above, the efficiencies of calculations can be improved evidently. In the second part, the methods of simulating the response of neutron dosimeters are presented. An Alnor albedo dosimeter was modelled in MCNP, and it has been simulated in the facility to calculate the calibration factor to get the evaluated response to a Cf-252 source. The angular response of Makrofol detectors to fast neutrons has also been investigated. As a kind of SSNTD, Makrofol can detect fast neutrons by recording the neutron induced heavy charged recoils. To obtain the information of charged recoils, general-purpose Monte Carlo codes were used for transporting incident neutrons. The response of Makrofol to fast neutrons is dependent on several factors. Based on the parameters which affect the track revealing, the formation of visible tracks was determined. For

  5. NSDUAZ unfolding package for neutron spectrometry and dosimetry with Bonner spheres

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Martinez B, M. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Ortiz R, J. M., E-mail: fermineutron@yahoo.com [Universidad Autonoma de Zacatecas, Unidad Academica de Ingenieria Electrica, Av. Ramon Lopez Velarde 801, Col. Centro, 98000 Zacatecas (Mexico)

    2011-10-15

    NSDUAZ (Neutron Spectrometry and Dosimetry for the Universidad Autonoma de Zacatecas) is a user friendly neutron unfolding package for Bonner sphere spectrometer with {sup 6}Lil(Eu) developed under Lab View environment. Unfolding is carried out using a recursive iterative procedure with the SPUNIT algorithm, where the starting spectrum is obtained from a library initial guess spectrum to start the iterations, the package include a statistical procedure based on the count rates relative to the count rate in the 8 inches-diameter sphere to select the initial spectrum. Neutron spectrum is unfolded in 32 energy groups ranging from 10{sup -8} up to 231.2 MeV. (Author)

  6. Dose-equivalent response CR-39 track detector for personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Oda, K.; Ito, M.; Yoneda, H.; Miyake, H.; Yamamoto, J.; Tsuruta, T.

    1991-01-01

    A dose-equivalent response detector based on CR-39 has been designed to be applied for personnel neutron dosimetry. The intrinsic detection efficiency of bare CR-39 was first evaluated from irradiation experiments with monoenergetic neutrons and theoretical calculations. In the second step, the radiator effect was investigated for the purpose of sensitization to fast neutrons. A two-layer radiator consisting of deuterized dotriacontane (C 32 D 66 ) and polyethylene (CH 2 ) was designed. Finally, we made the CR-39 detector sensitive to thermal neutrons by doping with orthocarbone (B 10 H 12 C 2 ), and also estimated the contribution of albedo neutrons. It was found that the new detector - boron-doped CR-39 with the two-layer radiator - would have a flat response with an error of about 70% in a wide energy region, ranging from thermal to 15 MeV. (orig.)

  7. Fast neutron dosimetry: [Progress report, 1986-1987

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Gould, M.N.; Meisner, L.F.; Pearson, D.W.

    1987-01-01

    A new research area was initiated in ultrasoft x-rays with the University of Wisconsin 1-GeV electron storage ring used as a radiation source. A new beam line and irradiation apparatus was designed and constructed. Amongst the distinguishing features are an irradiation vessel of considerable generality allowing many types of radiological/biological experiments to be performed; the ability to maintain low-pressure, high humidity environments with good control; and a computer controlled sample slide for [X,Y,Z] motions of high precision that allows fully controlled velocities and accelerations for complex sample irradiations. Work in the area of chromosomal aberration studies has continued after the completion of the investigation into the possible synergistic effects of mixed beams of neutrons and photons. Of special interest is the damage dependence on absorbed dose and dose rate for low-dose and low-dose rate exposures to high LET radiation. A unique microdosimetric instrument was employed in the continuing effort to measure dose distribution in LET from fast neutron irradiation of metal-metal oxide walls. Our purpose is to determine this distribution for oxygen, an element of critical importance to fast neutron dosimetry. 31 refs., 7 figs., 2 tabs

  8. Optimization of CR-39 for fast neutron dosimetry applications

    CERN Document Server

    Vilela, E; Giacomelli, G; Giorgini, M; Morelli, B; Patrizii, L; Serra, P; Togo, V

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: sup 2 sup 4 sup 1 Am-Be, sup 2 sup 5 sup 2 Cf and sup 2 sup 3 sup 8 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose.

  9. Individual neutron monitoring in workplaces with mixed neutron/proton radiation

    International Nuclear Information System (INIS)

    Bolognese-Milsztajn, T.; Bartlett, D.; Boschung, M.; Coeck, M.; Curzio, G.; D'Errico, F.; Fiechtner, A.; Giusti, V.; Gressier, V.; Kylloenen, J.; Lacoste, V.; Lindborg, L.; Luszik-Bhadra, M.; Molinos, C.; Pelcot, G.; Reginatto, M.; Schuhmacher, H.; Tanner, R.; Vanhavere, F.; Derdau, D.

    2004-01-01

    EVIDOS ('evaluation of individual dosimetry in mixed neutron and photon radiation fields') is an European Commission (EC)-sponsored project that aims at a significant improvement of radiation protection dosimetry in mixed neutron/photon fields via spectrometric and dosimetric investigations in representative workplaces of the nuclear industry. In particular, new spectrometry methods are developed that provide the energy and direction distribution of the neutron fluence from which the reference dosimetric quantities are derived and compared to the readings of dosemeters. The final results of the project will be a comprehensive set of spectrometric and dosimetric data for the workplaces and an analysis of the performance of dosemeters, including novel electronic dosemeters. This paper gives an overview of the project and focuses on the results from measurements performed in calibration fields with broad energy distributions (simulated workplace fields) and on the first results from workplaces in the nuclear industry, inside a boiling water reactor and around a spent fuel transport cask. (authors)

  10. Neutron dosimetry in containment of a pressurized water reactor utilizing the Panasonic UD-802 dosimetry system

    International Nuclear Information System (INIS)

    Kralick, S.C.

    1984-01-01

    The Panasonic UD-802 dosimeter was evaluated as a potential neutron dosimeter for use in containment of a PWR. The Panasonic UD-802 dosimeter, although designed as a beta and gamma dosimeter, is also sensitive to neutrons. UD-802 dosimeters were mounted on polyethylene phantoms and irradiated to known doses at selected locations in containment. The known neutron dose equivalents were determined based on remmeter dose rate measurements and stay times. The thermoluminescent response of the dosimeters and the known neutron dose equivalents were used to obtain a calibration factor at each location. The average calibration factor was 3.7 (unit of dosimeter response per mrem) and all calibration factors were within +-30% of this mean value. The dosimeter distance from the phantom was found to have minimal effect on the response but the system was directionally dependent, necessitating a correction in the calibration factor. The minimum significant dosimeter response was determined independent of any calibration factor. The minimum significant response of the UD-802 to neutrons is a function of the corresponding gamma exposure rate. It is concluded that the Panasonic UD-802 dosimeter can be used for neutron dosimetry in PWR containment

  11. Light-water-reactor pressure-vessel surveillance dosimetry using solid-state track recorders

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Roberts, J.H.; Gold, R.; Preston, C.C.

    1983-07-01

    The accumulation of neutron dose by the pressure vessel of an operating nuclear power plant results in damage in the form of steel embrittlement. In order to ascertain the safe operating lifetime of the reactor pressure vessel, dosimetric measurements must be made to evaluate the neutron dose to the pressure vessel and relate this dose to the cumulative radiation damage. Advanced dosimetry techniques are being evaluated for surveillance of operating reactors. Solid-state track recorder (SSTR) techniques are included among these advanced dosimetry techniques. Described herein are low neutron fluence calibration and standardization measurements that are being carried out in pressure vessel mockup benchmark neutron fields in the USA, Belgium, and England. In addition, high fluence SSTR dosimetry capsules have been irradiated with metallurgical specimens in a pressure vessel mockup facility. The design and deployment of advances SSTR dosimetry capsules in operating power reactors are also described

  12. Survivor dosimetry. Part D. Graphical comparisons of measurements and calculations for neutrons and gamma rays

    International Nuclear Information System (INIS)

    Egbert, Stephen D.; Cullings, Harry M.

    2005-01-01

    An important part of validating the DS02 dosimetry system is the comparison of calculated initial neutron and gamma-ray radiation activation from the atomic bombs with all measurements that have been made, both before and during this current dosimetry reevaluation. All measurements that were made before the year 2002 are listed in Table 5 of Chapter 4. Many of these measurements have been compared to previous versions of the dosimetry systems for Hiroshima and Nagasaki. In this section the measurements are compared to the new dosimetry system DS02. For the purposes of showing historical context, they are also compared to the previous dosimetry system DS86. References for these measurements are found in Chapter 4. (J.P.N.)

  13. Benchmark calculations with simple phantom for neutron dosimetry (2)

    International Nuclear Information System (INIS)

    Yukio, Sakamoto; Shuichi, Tsuda; Tatsuhiko, Sato; Nobuaki, Yoshizawa; Hideo, Hirayama

    2004-01-01

    Benchmark calculations for high-energy neutron dosimetry were undertaken after SATIF-5. Energy deposition in a cylindrical phantom with 100 cm radius and 30 cm depth was calculated for the irradiation of neutrons from 100 MeV to 10 GeV. Using the ICRU four-element loft tissue phantom and four single-element (hydrogen, carbon, nitrogen and oxygen) phantoms, the depth distributions of deposition energy and those total at the central region of phantoms within l cm radius and at the whole region of phantoms within 100 cm radius were calculated. The calculated results of FLUKA, MCNPX, MARS, HETC-3STEP and NMTC/JAM codes were compared. It was found that FLUKA, MARS and NMTC/JAM showed almost the same results. For the high-energy neutron incident, the MCNP-X results showed the largest ones in the total deposition energy and the HETC-3STEP results show'ed smallest ones. (author)

  14. Patient dosimetry improvements in longitudinal field MRI linear accelerators

    International Nuclear Information System (INIS)

    Oborn, B.M.; Metcalfe, P.E.; Butson, M.J.; Keall, P.

    2010-01-01

    Full text: Many studies exist of the often undesirable dosimetry changes in transverse field MRI-Linacs. Currently there are plans by different groups around the world to develop longitudinal MRT-Linac systems as dosimetry is potentially superior to transverse field sy tems. The objective of this study is to investigate via Monte Carlo simulations, the potential dosimetry improvements expected in lo gitudinal MRI-Linac designs over transverse field designs for advanced image-guided radiotherapy (IGRT). Geant4 Monte Carlo simulations have been performed of the dosimetry from a Varian 2100c 6 MV photon beam in lo gitudinal magnetic field typical of expected MRI-Linac designs. A 30 x 30 x 20 cm' phantom has been simulated in magnetic fields between 0 and 3 T. Beam profiles and skin dose calculations have been performed and compared with transverse field systems. Results The longitudinal magnetic field acts to reduce lateral dose spread in all locations within a patient. As well as this, the electron return effcct is absent. This equates to reductions in penumbral widths and reductions in skin dose. When compared with transverse field systems the dosimetry is superior. This will also allow for further reductions in trcatment margins as compared to transverse field MRI Linac designs.

  15. Experimental study and Monte Carlo modeling of operational quantities in metrology of ionizing radiation: application to neutrons dosimetry by radio-photoluminescence

    International Nuclear Information System (INIS)

    Salem, Youbba-Ould

    2014-01-01

    We characterize a passive dosimeter capable of measuring both fast and thermal neutrons for ambient and personal dosimetry. These neutrons can be detected in a mixed neutron-gamma field with appropriate converters (polyethylene for fast neutrons, cadmium for thermal neutrons). Monte Carlo simulations with MCNPX helped with the geometrical conception of the dosimeter and the choice of materials. The responses of the RPL dosimeter to these neutrons are linear in H * (10) and H p (10) with detection limits of 2 mSv for fast neutrons and 0.19 mSv for thermal neutrons. The angular dependencies are satisfactory according to the ISO 21909 norm. A calibration factor of (9.5 ± 0.5)*10 -2 mSv.cm 2 /RPL signal is obtained to the fast neutrons of the IPHC's 241 Am-Be calibrator. This factor is (9.7 ± 0.3)*10 -3 mSv.cm 2 /RPL signal for the thermalized neutrons. (author)

  16. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  17. Application of Monte Carlo codes to neutron dosimetry

    International Nuclear Information System (INIS)

    Prevo, C.T.

    1982-01-01

    In neutron dosimetry, calculations enable one to predict the response of a proposed dosimeter before effort is expended to design and fabricate the neutron instrument or dosimeter. The nature of these calculations requires the use of computer programs that implement mathematical models representing the transport of radiation through attenuating media. Numerical, and in some cases analytical, solutions of these models can be obtained by one of several calculational techniques. All of these techniques are either approximate solutions to the well-known Boltzmann equation or are based on kernels obtained from solutions to the equation. The Boltzmann equation is a precise mathematical description of neutron behavior in terms of position, energy, direction, and time. The solution of the transport equation represents the average value of the particle flux density. Integral forms of the transport equation are generally regarded as the formal basis for the Monte Carlo method, the results of which can in principle be made to approach the exact solution. This paper focuses on the Monte Carlo technique

  18. OPTIMIZATION OF A NEUTRON BEAM SHAPING ASSEMBLY DESIGN FOR BNCT AND ITS DOSIMETRY SIMULATION BASED ON MCNPX

    Directory of Open Access Journals (Sweden)

    I Made Ardana

    2017-10-01

    OPTIMASI DESAIN KOLIMATOR NEUTRON UNTUK SISTEM BNCT DAN UJI DOSIMETRINYA MENGGUNAKAN PROGRAM MCNPX. Telah dilakukan penelitian tentang sistem BNCT yang meliputi dua tahapan simulasi dengan menggunakan program MCNPX yaitu uji simulasi untuk optimasi desain kolimator neutron untuk sistem BNCT berbasis Siklotron 30 MeV dan uji simulasi untuk menghitung fluks neutron dan dosimetri radiasi pada kanker sarkoma jaringan lunak pada leher dan kepala. Tujuan simulasi untuk mendapatkan desain kolimator yang paling optimal dalam memoderasi fluks neutron cepat yang dihasilkan dari sistem target berilium sehingga dapat dihasilkan fluks neutron yang sesuai untuk sistem BNCT. Uji optimasi dilakukan dengan cara memvariasikan bahan dan ketebalan masing-masing komponen dalam kolimator seperi reflektor, moderator, filter neutron cepat, filter neutron thermal, filter radiasi gamma dan lubang keluaran. Desain kolimator yang diperoleh dari hasil optimasi tersusun atas moderator berbahan Al dengan ketebalan 39 cm, filter neutron cepat berbahan LiF2 setebal 8,2 cm, dan filter neutron thermal berbahan B4C setebal 0,5 cm. Untuk reflektor, filter radiasi gamma dan lubang keluaran masing-masing menggunakan bahan PbF2, Pb dan Bi. Fluks neutron epithermal yang dihasilkan dari kolimator yang didesain adalah sebesar 2,83 x 109 n/s cm-2 dan telah memenuhi seluruh parameter fluks neutron yang sesuai untuk sistem BNCT. Selanjutnya uji simulasi dosimetri pada kanker sarkoma jaringan lunak pada leher dan kepala dilakukan dengan cara memvariasikan konsentrasi senyawa boron pada model phantom leher manusia (ORNL. Selanjutnya model phantom tersebut diiradiasi dengan fluks neutron yang berasal dari kolimator yang telah didesain sebelumnya. Hasilnya, fluks neutron thermal mencapai nilai tertinggi pada kedalaman 4,8 cm di dalam model phantom leher ORNL dengan laju dosis tertinggi terletak pada area jaringan kanker. Untuk masing-masing variasi konsentrasi senyawa boron pada model phantom leher ORNL supaya

  19. Characterization of fuel distribution in the Three Mile Island Unit 2 (TMI-2) reactor system by neutron and gamma-ray dosimetry

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Ruddy, F.H.; Preston, C.C.; McNeece, J.P.; Kaiser, B.J.; McElroy, W.N.

    1984-01-01

    Neutron and gamma-ray dosimetry are being used for nondestructive assessment of the fuel distribution throughout the Three Mile Island Unit 2 (TMI-2) reactor core region and primary cooling system. The fuel content of TMI-2 makeup and purification Demineralizer A has been quantified with Si(Li) continuous gamma-ray spectrometry and solid-state track recorder (SSTR) neutron dosimetry. For fuel distribution characterization in the core region, results from SSTR neutron dosimetry exposures in the TMI-2 reactor cavity are presented. These SSTR results are consistent with the presence of a significant amount of fuel debris, equivalent to several fuel assemblies or more, lying at the bottom of the reactor vessel. (Auth.)

  20. U and Th thin film neutron dosimetry for fission-track dating: application to the age standard Moldavite

    International Nuclear Information System (INIS)

    Iunes, P.J.; Bigazzi, G.; Hadler Neto, J.C.; Laurenzi, M.A.; Balestrieri, M.L.; Norelli, P.; Osorio Araya, A.M.; Guedes, S.; Tello S, C.A.; Paulo, S.R.; Moreira, P.A.F.P.; Palissari, R.; Curvo, E.A.C.

    2005-01-01

    Neutron dosimetry based on U and Th thin films was used for fission-track dating of the age standard Moldavite, the central European tektite, from the Middle Miocene deposit of Jankov (southern Bohemia, Czech Republic). Our fission-track age (13.98+/-0.58Ma) agrees with a recent 40 Ar/ 39 Ar age, 14.34+/-0.04Ma, based on several determinations on Moldavites from different sediments, including the Jankov deposit. This result indicates that the U and Th thin film neutron dosimetry represents a reliable alternative for an absolute approach in fission-track dating

  1. Dosimetry Characterization of the Neutron Fields of the Intermediate Temporary Storage of the Trillo Nuclear Power Plant

    International Nuclear Information System (INIS)

    Campo Blanco, X.

    2015-01-01

    The Neutron Standards Laboratory of CIEMAT, in collaboration with the Trillo Nuclear Power Plant, has conducted a detailed dosimetric and spectrometric characterization of the neutron fields at the Intermediate Temporary Storage of the Trillo Nuclear Power Plant, as well as the neutron fields of ENSA-DPT spent fuel casks. For neutron measurements, neutron monitors and a Bonner spheres spectrometry system have been used. In addition, a Monte Carlo model of the installation and the cask has been developed and validated.

  2. Dating by fission track method: study of neutron dosimetry with natural uranium thin films; Datacao com o metodo dos tracos de fissao: estudo da dosimetria de neutrons com filmes finos de uranio natural

    Energy Technology Data Exchange (ETDEWEB)

    Iunes, P J

    1990-06-01

    Fission track dating is described, focalizing the problem of the decay constant for spontaneous fission of {sup 238} U and the use of neutron dosimetry in fission track analysis. Experimental procedures using thin films of natural uranium as neutron dosimeters and its results are presented. The author shows a intercomparison between different thin films and between the dosimetry with thin film and other dosimetries. (M.V.M.). 52 refs, 12 figs, 9 tabs.

  3. Development of improved procedures for evaluation of neutron cross sections for reactor neutron dosimetry

    International Nuclear Information System (INIS)

    Vonach, H.

    1980-06-01

    The cross-sections for the four important neutron dosimetry reactions 19 F(n,2n) 18 F, 31 P(n,p) 31 Si, 93 Nb(n,n')sup(93m)Nb and 103 Rh(n,n')sup(103m)Rh were evaluated in the neutron energy range from threshold to 20 MeV. For the 19 F(n,2n) reaction the evaluation could be based entirely on experimental data; for the reactions 31 P(n,p) 31 Si and 103 Rh(n,n')sup(103m)Rh large gaps in the experimental excitation functions and large discrepancies between the existing data made it necessary to supplement the experimental data by cross-section calculations and to give about equal weight to the experimental and calculated cross-sections. For the 93 Nb(n,n')sup(93m)Nb reaction the evaluation had to be based entirely on the theoretically calculated cross-sections. The cross-section calculations were performed using the statistical model of nuclear reactions allowing for precompound processes in the first reaction step and errors of the calculated cross-sections were estimated from their sensitivity to the various input parameters. Cross-section values were evaluated for energy groups between 0.1 MeV and 1 MeV wide, the width depending on both the slope of the excitation functions and the density of the available data. For each evaluated cross-section also an uncertainty (on a 1 sigma confidence level) was derived taking into account the errors given by the experimentalists, the general consistency of the experimental data and the estimated errors of the theoretically calculated cross-sections. In addition relative correlation matrices were derived for each evaluated excitation function describing the correlations between the uncertainties of the cross-sections at different energies. The correlations between the cross-section uncertainties for different reactions were found to be negligible. The results of this evaluation as well as those of Ref. 1 will be combined with the ENDF/B-V dosimetry file into an international neutron dosimetry file by the nuclear data section of

  4. Comparison of different PADC materials and etching conditions for fast neutron dosimetry

    International Nuclear Information System (INIS)

    Assenmacher, F.; Boschung, M.; Hohmann, E.; Mayer, S.

    2016-01-01

    Etched-track polyallyl diglycol carbonate (PADC) dosemeters have been in use at the Paul Scherrer Institute since 1998 in neutron dosimetry for individual monitoring. In the last years, the availability of PADC materials from different manufacturers has grown, and different etching conditions were proposed, with the intention to improve the quality and overall performance of PADC in individual neutron monitoring. The goal of the present study was to compare the performance of different PADC materials and to investigate the influence of different etching conditions on sensitivity to fast neutrons and lower detection limit. The comparison covers six different PADC materials and eight different etching conditions. (authors)

  5. Fast neutron dosimetry by means of different solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The comparative study of three different types of fast neutron dosimeters based on solid state nuclear track detectors is presented; the dosimeters studied were: - microscopic soda glass in contact with 232 Th; - polycarbonate Makrofol E; and - cellulose nitrate Kodak LR 115. All detectors were evaluated by visual counting in a microscope. The authors have studied such properties as the background, angular as well as energetical dependences of detectors. The results obtained show that all studied detectors are suitable for fast neutron dosimetry; their application depends however on the concrete experimental conditions (neutron spectrum, fluence etc.). Both advantages and disadvantages of each of them are presented. (Auth.)

  6. The implications of the publication 92 of the ICRP for the neutron dosimetry

    International Nuclear Information System (INIS)

    Thomas, R.H.

    2004-01-01

    This article gives some comments on the neutron dosimetry in the publication 92 called 'Relative Biological Effectiveness, Quality factor and Radiation weighting factor'. the accent is put on the question of the weighting factor given to the radiation. (N.C.)

  7. Neutron metrology file NMF-90. An integrated database for performing neutron spectrum adjustment calculations

    International Nuclear Information System (INIS)

    Kocherov, N.P.

    1996-01-01

    The Neutron Metrology File NMF-90 is an integrated database for performing neutron spectrum adjustment (unfolding) calculations. It contains 4 different adjustment codes, the dosimetry reaction cross-section library IRDF-90/NMF-G with covariances files, 6 input data sets for reactor benchmark neutron fields and a number of utility codes for processing and plotting the input and output data. The package consists of 9 PC HD diskettes and manuals for the codes. It is distributed by the Nuclear Data Section of the IAEA on request free of charge. About 10 MB of diskspace is needed to install and run a typical reactor neutron dosimetry unfolding problem. (author). 8 refs

  8. Characterisation of neutron fields: challenges in assessing the directional distribution

    International Nuclear Information System (INIS)

    Cauwels, Vanessa; Vanhavere, Filip; Reginatto, Marcel

    2014-01-01

    The SCK.CEN has carried out neutron field characterisation campaigns at several nuclear reactors. The main goal of these measurement campaigns was to evaluate the performance of different neutron personal dosemeters. To be able to evaluate the performance of neutron personal dosemeters in terms of H p (10), knowledge of the directional distribution is indispensable. This distribution was estimated by placing several personal dosemeters on all six sides of a slab phantom. The interpretation and conversion of this information into a reliable value for H p (10) requires great care. The data were analysed using three methods. In the first approach, a linear interpolation was performed on three perpendicular axes. In the other two approaches, an icosahedron was used to model the angle of incidence of the neutrons and a linear interpolation or a Bayesian analysis was performed. This study describes the limitations and advantages of each of these methods and provides recommendations for their use to estimate the personal dose equivalent H p (10) for neutron dosimetry. Neutron personal dosimetry is complicated by the fact that the neutron dose quantity H p (10) is strongly energy and angular dependent. Instead of simply assuming that the fluence is unidirectional or that the fluence is isotropic, an attempt was made to estimate the directional distribution of the neutron field using a relatively simple measurement procedure. A number of active and passive personal dosemeters were placed on the six faces of a slab phantom and the results were analysed via different algorithms to obtain partial fluences in several directions of incidence. The results from all calculations in this study show the importance of introducing information about the directional distribution of the neutron fluence for the estimation of the personal dose equivalent H p (10). The difference between H p (10) dose estimates carried out using a unidirectional or an isotropic distribution can be of up

  9. Fast neutron personnel dosimetry by CR-39 plastics a new electrochemical etching procedure

    International Nuclear Information System (INIS)

    Djeffal, S.

    1984-07-01

    In the first part of this work a brief description of solid state nuclear track detectors, the principles of track registration and the different reading techniques are given. In the experimental part of the present work we systematically analysed different etching procedures and set a new electrochemical etching method, which enables us to develop a new fast neutron dosimeter. This fast neutron dosimeter makes possible the measurement of low neutron doses in the energy range from 10 Kev to 20 Mev with a reasonably flat energy response. These new developments are very attractive in personnel neutron dosimetry where nuclear emulsions are still used despite their insensitivity to neutron energies down to 500 Kev (i.e. the energy range one often encounters around nuclear facilities)

  10. Improvement of JCDS, a computational dosimetry system in JAEA for neutron capture therapy

    International Nuclear Information System (INIS)

    Kumada, Hiroaki; Yamamoto, Kazuyoshi; Matsumura, Akira; Yamamoto, Tetsuya; Nakagawa, Yoshinobu; Kageji, Teruyoshi

    2006-01-01

    JCDS, a computational dosimetry system for neutron capture therapy, was developed by Japan Atomic Energy Agency. The system has been sophisticated to facilitate dose planning so far. In dosimetry with JCDS for BNCT clinical trials at JRR-4, several absorbed doses and the dose distributions are determined by a voxel model consisted of 2x2x2mm 3 voxel cells. By using the detailed voxel model, accuracy of the dosimetry can be improved. Clinical trials for melanoma and head-and-neck cancer as well as brain tumor were started using hot version of JCDS in 2005. JCDS is also being of improved so as to enable a JCDS application to dosimetry by PHITS as well as dosimetry by MCNP. By using PHITS, total doses of a patient by a combined modality therapy, for example a combination of BNCT and proton therapy, can be estimated consistently. Moreover, PET images can be adopted in combination with CT and MRI images as a farsighted approach. JCDS became able to identify target regions by using the PET values. (author)

  11. Evidos: optimisation of individual monitoring in mixed neutron/photon fields at workplaces of the nuclear fuel cycle

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Lacoste, V.; Muller, M.; Boschung, M.; Fiechtner, A.; Coeck, M.; Vanhavere, F.; Curzio, G.; D'errico, F.; Kyllonen, J.E.; Lindborg, L.; Molinos, C.; Tanner, R.; Derdau, D.; Lahaye, Th.

    2005-01-01

    Within its 5. Framework Programme, the EC is funding the project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The aim of this project is the optimisation of individual monitoring at workplaces of the nuclear fuel cycle with special regard to neutrons. Various dosemeters for mixed field application - passive and new electronic devices - are tested in selected workplace fields in nuclear installations in Europe. The fields are characterised using a series of spectrometers that provide the energy distribution of neutron fluence (Bonner spheres) and newly developed devices that provide the energy and directional distribution of the neutron fluence. Results from the first measurement campaign, carried out in simulated workplace fields (IRSN, Cadarache. France), and those of a second measurement campaign, carried out at workplaces at a boiling water reactor and at a storage cask with used fuel elements (Kernkraftwerk Kriimmel, Germany), are described. (authors)

  12. Introduction to dosimetry and risk estimation of second cancer induction following radiotherapy

    International Nuclear Information System (INIS)

    Harrison, R.M.

    2013-01-01

    This brief review of dosimetry in second cancer dosimetry introduces work carried out by Working Group 9 (Radiation Protection Dosimetry in Medicine) of the European Radiation Dosimetry Group (EURADOS). The work described in the following papers in this edition was presented at a Workshop on Dosimetry for Second Cancer Risk Estimation given at the EURADOS Annual meeting in Vienna on February 8th 2012. The work concentrates on the measurement of out-of-field doses in water tanks and BOMAB-like phantoms using a variety of dosimeters to measure photon and neutron doses. These include optically stimulated luminescence (OSL), radiophotoluminescence (RPL) and thermoluminescence (TLD) dosimeters for photon dosimetry (together with ion chambers for reference measurements traceable to primary standards) and track etch and bubble detectors for neutron measurements. A discussion of the various phantoms available for these measurements is presented together with a brief introduction to a model for the relationship between organ doses and the risk of induction of second cancers. The estimation of second cancer risks is not trivial and involves processes which are currently incompletely understood. However, progress in this field requires a robust foundation and methodology for the measurement or calculation of organ doses following radiotherapy, so that risks can be placed in perspective, algorithms for out-of-field doses can be compared with measured data, and future epidemiological studies may have a reliable foundation of organ dosimetry for retrospective dosimetry studies. -- Highlights: ► Brief review of second cancer induction following radiotherapy. ► Out-of-field doses for estimating risks to remote organs. ► Introduction to dosimetry techniques and dosimeters used. ► Out-of-field dose measurements in phantoms

  13. Simulation of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation

    International Nuclear Information System (INIS)

    Kluson, J.; Jansky, B.

    2009-01-01

    Reference mixed neutron-gamma fields are used for test and calibration of dosimetric and spectrometric systems, intercomparison measurements, and benchmark tests and represent experimental base for reactor studies. Set of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation was build in the NRI Rez. Extended sets of measurements and simulation calculations were done to describe the reference mixed field dosimetry and spectral characteristics with best achievable precision. The Monte Carlo technique was used for different experimental setups models description, comparison and verification and field characteristics simulation. Effects (hardly distinguishable experimentally) were also studied ( contributions from individual parts of experimental setup, field individual components and next effects as shadow shield cones transparency, etc.). Some results and main conclusions of these studies and calculations are presented and discussed. (authors)

  14. Simulation of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation

    International Nuclear Information System (INIS)

    Kluson, J.; Jansky, B.

    2008-01-01

    Reference mixed neutron-gamma fields are used for test and calibration of dosimetric and spectrometric systems, intercomparison measurements, and benchmark tests and represent experimental base for reactor studies. Set of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation was build in the NRI Rez. Extended sets of measurements and simulation calculations were done to describe the reference mixed field dosimetry and spectral characteristics with best achievable precision. The Monte Carlo technique was used for different experimental setups models description, comparison and verification and field characteristics simulation. Effects (hardly distinguishable experimentally) were also studied ( contributions from individual parts of experimental setup, field individual components and next effects as shadow shield cones transparency, etc.). Some results and main conclusions of these studies and calculations are presented and discussed. (authors)

  15. Integrating techniques for neutron dosimetry in Linac 18 MV

    International Nuclear Information System (INIS)

    Ceron R, P. V.; Diaz G, J. A. I.; Rivera M, T.; Paredes G, L. C.; Vega C, H. R.

    2015-10-01

    In this paper thermoluminescent dosimetry, analytical techniques and Monte Carlo calculations were used to estimate the neutron dose equivalent in a radiotherapy room with a linear electron accelerator of 18 MV. The equivalent dose was measured at isocenter to 1.42 m of target and at the entrance of the labyrinth of the room of a Novalis Tx. The neutron detectors were constructed with pairs of thermoluminescent dosimeters TLD 600 ( 6 LiF: Mg, Ti) and TLD 700 ( 7 LiF: Mg, Ti) which are placed inside a paraffin sphere of 20 cm in diameter. These measurements enabled the calculation of equivalent dose in the gate and the source term, using the relationships contained in the NCRP-151. Through the models carried out with the code MCNPX the absorbed dose distribution with regard to depth in a paraffin phantom are included and the neutron spectrum produced by the head, taking into account the geometry and component materials. The results are in the order of neutron milli sievert by gray of X-rays (mSv/Gy x) which are in the same order as those found in other reports for different accelerators. (Author)

  16. Minutes of the 13th light water reactor pressure vessel surveillance dosimetry improvement program (LWR-PV-SDIP) meeting

    International Nuclear Information System (INIS)

    1984-04-01

    Information is presented concerning ASTM LWR standards and program documentation; trend curves, PSF, and other test reactor metallurgical programs; PSF dosimetry and metallurgical capsule neutron and gamma environment characterization and metallurgical studies; PVS characterization program; other neutron fields; surveillance dosimetry measurement facility (SDMF) and perturbation studies; transport theory calculations; gamma field benchmarks and photo-reaction studies; and fission and non-fission sensor inventories and quality assurance

  17. Research Laboratory of Mixed Radiation Dosimetry

    International Nuclear Information System (INIS)

    2002-01-01

    Full text: Two main topics of the research work in the Laboratory of Mixed Radiation Dosimetry in 2001 were: development of recombination methods for dosimetry of mixed radiation fields and maintenance and development of unique in Poland reference neutron fields. Additionally research project on internal dosimetry were carried out in collaboration with Division of Radiation Protection Service. RECOMBINATION METHODS Recombination methods make use of the fact that the initial recombination of ions in the gas cavity of the ionization chamber depends on local ionization density. The later can be related to linear energy transfer (LET) and provides information on radiation quality of the investigated radiation fields. Another key feature of the initial recombination is that it does not depend of dose rate. Conditions of initial (local) recombination can be achieved in specially designed high pressure tissue-equivalent ionization chambers, called the recombination chambers. They are usually parallel-plate ionization chambers filled with a tissue-equivalent gas mixture under a pressure of order 1 MPa. The spacing between electrodes is of order of millimeters. At larger spacing, the volume recombination limits the maximum dose rate at which the chamber can be properly operated. The output of the chamber is the ionization current (or collected charge) as a function of collecting voltage. All the recombination methods require the measurement of the ionization current (or charge) at least at two values of the collecting voltage applied to the chamber. The highest voltage should provide the conditions close to saturation (but below discharge or multiplication). The ionization current measured at maximum applied voltage is proportional to the absorbed dose, D, (some small corrections for lack of saturation can be introduced when needed). Measurements at other voltages are needed for the determination of radiation quality. The total dose equivalent in a mixed radiation field is

  18. The dielectric track and thermoluminescent detectors applied to neutron dosimetry in personnel monitoring

    International Nuclear Information System (INIS)

    Mebhah, D.

    1984-03-01

    The personnal dosimeter for neutron based on the detection of fission fragments from 237 Np and 232 Th by a polycarbonate 10 gm, and lithium fluorite 6 LIF/ 7 LIF, allow to cover an energy spectrum from 0.05 eV to 14 MeV with a easy neutron gamma discrimination. In criticality dosimetry, the energy spectrum of the incident neutrons can be defined by two components: the fast component by E b exp(-ae) with E between 0.1 and 14 MeV, a and b determined by a combination of 237 Np and 232 Th track detector responses, and the epithermal component in 1/E, the thermal component having a minor contribution to the total equivalent dose. We took into account the body influence on the detectors response by introducing effective cross section. The equivalent dose obtained by this dosimeter is 20% overestimated in low doses dosimetry. The interpretation of the detectors responses is based on the definition of a factor and a calibration parameter for each zone in which the spectrum is constant. The knowledge of this parameter for individual dosimeters allows to account for the variations of the conditions of calibration

  19. Application of the alanine detector to gamma-ray, X-ray and fast neutron dosimetry

    International Nuclear Information System (INIS)

    Waligorski, M.P.R.; Hansen, J.W.; Byrski, E.

    1987-01-01

    A dosimeter based on alanine has been developed at the INP in Krakow and at Risoe National Laboratory. Due to its near tissue-equivalence and stability of signal, measured using ESR spectrometry at room temperature, this free-radical amino-acid dosimetric system is particularly suitable for measuring X-ray, gamma-ray and fast neutron doses in the range 10-10 5 Gy. The relative effectiveness (with respect to 60 Co γ-rays) of the alanine dosimeter to 250 kVp X-rays and to cyclotron-produced fast neutrons (mean neutron energy 5.6 MeV) is measured to be 0.76± 0.06 and 0.60±0.05, respectively. The suitability of the alanine dosimeter for intercomparison gamma-ray dosimetry is also shown. The estimated absolute difference between 60 Co dosimetry at Risoe National Laboratory and at the Centre of Oncology in Krakow is about 5%, somewhat more than the experimental uncertainty. These results are based on ESR measurements performed in Krakow on about 25% of the exposed detectors. 28 refs., 2 figs., 3 tabs. (author)

  20. Detector for imaging and dosimetry of laser-driven epithermal neutrons by alpha conversion

    Science.gov (United States)

    Mirfayzi, S. R.; Alejo, A.; Ahmed, H.; Wilson, L. A.; Ansell, S.; Armstrong, C.; Butler, N. M. H.; Clarke, R. J.; Higginson, A.; Notley, M.; Raspino, D.; Rusby, D. R.; Borghesi, M.; Rhodes, N. J.; McKenna, P.; Neely, D.; Brenner, C. M.; Kar, S.

    2016-10-01

    An epithermal neutron imager based on detecting alpha particles created via boron neutron capture mechanism is discussed. The diagnostic mainly consists of a mm thick Boron Nitride (BN) sheet (as an alpha converter) in contact with a non-borated cellulose nitride film (LR115 type-II) detector. While the BN absorbs the neutrons in the thermal and epithermal ranges, the fast neutrons register insignificantly on the detector due to their low neutron capture and recoil cross-sections. The use of solid-state nuclear track detectors (SSNTD), unlike image plates, micro-channel plates and scintillators, provide safeguard from the x-rays, gamma-rays and electrons. The diagnostic was tested on a proof-of-principle basis, in front of a laser driven source of moderated neutrons, which suggests the potential of using this diagnostic (BN+SSNTD) for dosimetry and imaging applications.

  1. Calculation of dosimetry parameters for fast neutron radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wells, A.H.

    1978-05-01

    A computer simulation of the interactions of 50 MeV d/sup +/ on Be and 42 MeV p/sup +/ on Be neutron spectra with ICRU muscle tissue and Shonka A-150 tissue equivalent plastic was performed to allow computation of the charged particle spectra that result. Nuclear data were obtained from the Evaluated Nuclear Data File (ENDF) whenever possible and from the Intranuclear Cascade and Evaporation models otherwise. The dosimetry parameters calculated are: the kerma ratio, K/sub A-150//K/sub tissue/; the energy required to form an ion pair, W; and the stopping power ratio, S/sub g//sup W/.

  2. Calculation of dosimetry parameters for fast neutron radiotherapy

    International Nuclear Information System (INIS)

    Wells, A.H.

    1978-05-01

    A computer simulation of the interactions of 50 MeV d + on Be and 42 MeV p + on Be neutron spectra with ICRU muscle tissue and Shonka A-150 tissue equivalent plastic was performed to allow computation of the charged particle spectra that result. Nuclear data were obtained from the Evaluated Nuclear Data File (ENDF) whenever possible and from the Intranuclear Cascade and Evaporation models otherwise. The dosimetry parameters calculated are: the kerma ratio, K/sub A-150//K/sub tissue/; the energy required to form an ion pair, W; and the stopping power ratio, S/sub g//sup W/

  3. Experimental facilities for calibrations at the dosimetry facility of group 6.5 'Neutron dosimetry' at the Physikalisch-Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Strzelczyk, H.

    1986-07-01

    The mechanical and electrical layout of the ''Dosimetriemessplatz'', a low scattering target area at the accelerator facility is described. Monoenergetic neutrons are generated at the irradiation facility for the research on neutron detectors and dosimeters for radiation protection. The report is aimed to inform dosimetry in particular for those guest's coming from other laboratories. For that purpose a detailed description is given of the mechanical construction, of cable connections and of the monitor system. The feasibitity of data transfer from the system at the target position to the user's system and the mode of acceptance of external data are explained. (orig./HP) [de

  4. Testing and linearity calibration of films of phenol compounds exposed to thermal neutron field for EPR dosimetry.

    Science.gov (United States)

    Gallo, S; Panzeca, S; Longo, A; Altieri, S; Bentivoglio, A; Dondi, D; Marconi, R P; Protti, N; Zeffiro, A; Marrale, M

    2015-12-01

    This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was found and the signal was compared with that of commercial alanine films. Our analysis showed that gadolinium oxide (5% by weight) can enhance the thermal neutron sensitivity more than 18 times. Irradiated dosimetric films of phenolic compound exhibited EPR signal fading of about 4% after 10 days from irradiation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Neutron measuring instruments for radiation protection

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Schneider, W.; Hoefert, M.; Kuehn, H.; Jahr, R.; Wagner, S.; Piesch, E.

    1979-09-01

    The present report deals with selected topics from the field of neutron dosimetry for radiation protection connected with the work of the subcommittee 6802 in the Standards Committee on Radiology (NAR) of the German Standards Institute (DIN). It is a sort of material collection. The topics are: 1. Measurement of the absorbed-energy dose by a) ionization chambers in fields of mixed radiation and b) recoil-proton proportional counting tubes. 2. Measurement of the equivalent dose, neutron monitors, combination methods by a) rem-meters, b) recoil-proton counting tubes, c) recombination method, tissue-equivalent proportional counters, activation methods for high energies in fields of mixed radiation, d) personnel dosimetry by means of ionization chambers and counting tubes, e) dosimetry by means of activation methods, nuclear track films, nonphotographic nuclear track detectors and solid-state dosimeters. (orig./HP) [de

  6. Average cross sections calculated in various neutron fields

    International Nuclear Information System (INIS)

    Shibata, Keiichi

    2002-01-01

    Average cross sections have been calculated for the reactions contained in the dosimetry files, JENDL/D-99, IRDF-90V2, and RRDF-98 in order to select the best data for the new library IRDF-2002. The neutron spectra used in the calculations are as follows: 1) 252 Cf spontaneous fission spectrum (NBS evaluation), 2) 235 U thermal fission spectrum (NBS evaluation), 3) Intermediate-energy Standard Neutron Field (ISNF), 4) Coupled Fast Reactivity Measurement Facility (CFRMF), 5) Coupled thermal/fast uranium and boron carbide spherical assembly (ΣΣ), 6) Fast neutron source reactor (YAYOI), 7) Experimental fast reactor (JOYO), 8) Japan Material Testing Reactor (JMTR), 9) d-Li neutron spectrum with a 2-MeV deuteron beam. The items 3)-7) represent fast neutron spectra, while JMTR is a light water reactor. The Q-value for the d-Li reaction mentioned above is 15.02 MeV. Therefore, neutrons with energies up to 17 MeV can be produced in the d-Li reaction. The calculated average cross sections were compared with the measurements. Figures 1-9 show the ratios of the calculations to the experimental data which are given. It is found from these figures that the 58 Fe(n, γ) cross section in JENDL/D-99 reproduces the measurements in the thermal and fast reactor spectra better than that in IRDF-90V2. (author)

  7. 6LiF sandwich type detectors for low dose individual monitoring in mixed neutron-photon fields

    International Nuclear Information System (INIS)

    Olko, P.; Budzanowski, M.; Bilski, P.; Burgkhardt, B.; Piesch, E.

    1994-01-01

    ICRP Publication 60 recommends the reduction of the annual dose limit for occupational exposure from 50 to 20 mSv and a doubling of the quality factor for medium energy neutrons. If occupational doses are evaluated every month (which is obligatory e.g. in Germany and in Poland), the individual neutron dosemeter will have to measure neutron doses in the range of 100 μSv. No commercially available, automatic individual dosimetry monitoring system exists that fulfils this requirement. Some of the parameters which influence the evaluation of the neutron dose from readings of TL dosemeters have been studied in order to decrease the variance of the measured neutron signal. In mixed neutron-photon fields, clear separation of the neutron component from the total reading depends also on the uncertainty of the gamma dose measurements. While the thermal albedo neutrons are absorbed mostly at the surface of the 6 LiF detector, the reduction of the detector thickness results in a decrease of its photon sensitivity, while its neutron sensitivity is almost principally maintained. As a consequence, the uncertainty of gamma dose contributes with lower weight to the variance of the evaluated neutron signal. First tests of an optimised 200 μm thick sandwich detector and 0.9 mm thick standard LiF chips were made at low neutron and photon dose ranges using different readers, in order to determine the uncertainty versus dose for different neutron-photon combinations. The conditions under which the new sandwich type detectors may improve albedo neutron dosimetry are demonstrated. (Author)

  8. New solid-state effects used in neutron detection and dosimetry. 1

    International Nuclear Information System (INIS)

    Doerschel, B.; Hahn, G.

    1981-01-01

    A review is given of radiation effects on solids and their usability for personnel neutron dosimetry. Part 1 covers mechanical effects on the crystal lattice of solids (dislocations in copper foils and changes in the bulk modulus, unclear effects in quartz connected with changes in the oscillation frequency), thermal effects of metals embedded in type I superconductors (superheated colloid detectors) or other materials (superheated drop detectors)

  9. Computational methods in several fields of radiation dosimetry

    International Nuclear Information System (INIS)

    Paretzke, Herwig G.

    2010-01-01

    Full text: Radiation dosimetry has to cope with a wide spectrum of applications and requirements in time and size. The ubiquitous presence of various radiation fields or radionuclides in the human home, working, urban or agricultural environment can lead to various dosimetric tasks starting from radioecology, retrospective and predictive dosimetry, personal dosimetry, up to measurements of radionuclide concentrations in environmental and food product and, finally in persons and their excreta. In all these fields measurements and computational models for the interpretation or understanding of observations are employed explicitly or implicitly. In this lecture some examples of own computational models will be given from the various dosimetric fields, including a) Radioecology (e.g. with the code systems based on ECOSYS, which was developed far before the Chernobyl reactor accident, and tested thoroughly afterwards), b) Internal dosimetry (improved metabolism models based on our own data), c) External dosimetry (with the new ICRU-ICRP-Voxelphantom developed by our lab), d) Radiation therapy (with GEANT IV as applied to mixed reactor radiation incident on individualized voxel phantoms), e) Some aspects of nanodosimetric track structure computations (not dealt with in the other presentation of this author). Finally, some general remarks will be made on the high explicit or implicit importance of computational models in radiation protection and other research field dealing with large systems, as well as on good scientific practices which should generally be followed when developing and applying such computational models

  10. FNTD radiation dosimetry system enhanced with dual-color wide-field imaging

    International Nuclear Information System (INIS)

    Akselrod, M.S.; Fomenko, V.V.; Bartz, J.A.; Ding, F.

    2014-01-01

    At high neutron and photon doses Fluorescent Nuclear Track Detectors (FNTDs) require operation in analog mode and the measurement results depend on individual crystal color center concentration (coloration). We describe a new method for radiation dosimetry using FNTDs, which includes non-destructive, automatic sensitivity calibration for each individual FNTD. In the method presented, confocal laser scanning fluorescent imaging of FNTDs is combined with dual-color wide field imaging of the FNTD. The calibration is achieved by measuring the color center concentration in the detector through fluorescence imaging and reducing the effect of diffuse reflection on the lapped surface of the FNTD by imaging with infra-red (IR) light. The dual-color imaging of FNTDs is shown to provide a good estimation of the detector sensitivity at high doses of photons and neutrons, where conventional track counting is impeded by track overlap. - Highlights: • New method and optical imaging head was developed for FNTD used at high doses. • Dual-color wide-field imaging used for color center concentration measurement. • Green fluorescence corrected by diffuse reflection used for sensitivity correction. • FNTD dose measurements performed in analog processing mode

  11. Practical applications of the new ICRP recommendation to external dosimetry

    International Nuclear Information System (INIS)

    Kraus, W.

    1992-01-01

    Focussing on external dosimetry for occupational exposure the consequences of the new quantities equivalent dose (radiation weighting factor), effective dose (tissue weighting factor) and the ICRU operational quantities for individual and area dosimetry are discussed. Despite some arguments against the new quantities they should be introduced as rapidly as possible to keep international uniformity in radiation protection monitoring. It is shown that they provide a conservative estimate of the effective dose for photons and neutrons. In photon dosimetry only minor changes of the conversion factors relating operational quantities to effective dose is observed. In neutron dosimetry the conversion factors change by a factor of up to 2. It is pointed out that there is a urgent need to calculate standardized conversion factors for field quantities -operational quantities- organ and effective dose in a joint effort of ICRP and ICRU. This includes standardization of calibration methods for individual dosimetry using suitable phantoms instead of the sphere. (author)

  12. Evaluation of cross sections for 14 important neutron-dosimetry reactions

    International Nuclear Information System (INIS)

    Wagner, M.; Vonach, H.; Pavlik, A.; Strohmaier, B.; Tagesen, S.; Martinez-Rico, J.

    1990-01-01

    The evaluation of the cross sections for the neutron dosimetry reactions 24 Mg(n,p) 24 Na, 27 Al(n,α) 24 Na, 58 Ni(n,2n) 57 Ni, 64 Zn(n,p) 64 Cu, 90 Zr(n,2n) 89 Zr and 93 Nb(n,n') 93m Nb carried out at the IRK about ten years ago were updated taking into account recent experimental results. Besides, new evaluations were performed for four additional dosimetry reactions, namely 52 Cr(n,2n) 51 Cr, 59 Co(n,2n) 58 Co, 93 Nb(n,2n) 92m Nb and 197 Au(n,2n) 196 Au. The deadlines for the retrieval of data for the different reactions lay between March 1989 and February 1990. The evaluations comprise the neutron energy range from threshold to 20 MeV, in a few cases this range is extended up to 21 MeV or 30 MeV. Cross sections and their uncertainties were evaluated in energy groups with widths of 0.1 MeV to 2.0 MeV, and relative correlation matrices of the evaluated cross sections at different energies were derived. The results of the evaluations are compared to the previous ones and to other recent evaluations reported in the literature. The main results of our previous evaluations for the reactiosn 19 F(n,2n) 18 F, 31 P(n,p) 31 Si, 63 Cu(n,2n) 62 Cu and 103 Rh(n,n') 103m Rh which remain unchanged are also given for completeness. The evaluations reported in this work will be included in the new version of the IRDF (International Reactor Dosimetry File) of the IAEA in ENDF/B-VI format. (orig.)

  13. Advances in electron dosimetry of irregular fields

    International Nuclear Information System (INIS)

    Mendez V, J.

    1998-01-01

    In this work it is presented an advance in Electron dosimetry of irregular fields for beams emitted by linear accelerators. At present diverse methods exist which are coming to apply in the Radiotherapy centers. In this work it is proposed a method for irregular fields dosimetry. It will be allow to calculate the dose rate absorbed required for evaluating the time for the treatment of cancer patients. Utilizing the results obtained by the dosimetric system, it has been possible to prove the validity of the method describe for 12 MeV energy and for square field 7.5 x 7.5 cm 2 with percentile error less than 1 % . (Author)

  14. Neutron dosimetry system SAIPS: Manual for users and programmers (Version 87-02)

    International Nuclear Information System (INIS)

    Berzonis, M.A.; Bondars, Kh.Ya.; Niedritis, A.M.

    1988-07-01

    SAIPS is a system used for neutron dosimetry by foil activation, containing a package of programs and a data base of neutron activation cross-sections. A description is given of the SAIPS indexed procedures and users language, which are designed for producing input data for programs unfolding neutron spectra from reaction rate measurements, for carrying out calculations and processing and comparing the results obtained, for utilizing the additional capabilities of the system, and for setting up a working version of the system from the magnetic tapes used for distribution. A description is given of the logical structure of the data sets containing the libraries of neutron cross-section and a priori spectra and also the libraries of calculated spectra. The annexes give examples of SAIPS in use, of the contents of the a priori spectra and neutron cross-section libraries, and of the contents of the SAIPS distribution tapes. SAIPS contains programs in PL/1 (opt), FORTRAN IV(H) and ASSEMBLER. 25 refs

  15. ATR neutron spectral characterization

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J.W.; Anderl, R.A.

    1995-11-01

    The Advanced Test Reactor (ATR) at INEL provides intense neutron fields for irradiation-effects testing of reactor material samples, for production of radionuclides used in industrial and medical applications, and for scientific research. Characterization of the neutron environments in the irradiation locations of the ATR has been done by means of neutronics calculations and by means of neutron dosimetry based on the use of neutron activation monitors that are placed in the various irradiation locations. The primary purpose of this report is to present the results of an extensive characterization of several ATR irradiation locations based on neutron dosimetry measurements and on least-squares-adjustment analyses that utilize both neutron dosimetry measurements and neutronics calculations. This report builds upon the previous publications, especially the reference 4 paper. Section 2 provides a brief description of the ATR and it tabulates neutron spectral information for typical irradiation locations, as derived from the more historical neutron dosimetry measurements. Relevant details that pertain to the multigroup neutron spectral characterization are covered in section 3. This discussion includes a presentation on the dosimeter irradiation and analyses and a development of the least-squares adjustment methodology, along with a summary of the results of these analyses. Spectrum-averaged cross sections for neutron monitoring and for displacement-damage prediction in Fe, Cr, and Ni are given in section 4. In addition, section4 includes estimates of damage generation rates for these materials in selected ATR irradiation locations. In section 5, the authors present a brief discussion of the most significant conclusions of this work and comment on its relevance to the present ATR core configuration. Finally, detailed numerical and graphical results for the spectrum-characterization analyses in each irradiation location are provided in the Appendix.

  16. Fiscal year 1976T (add-on quarter) DT fusion neutron irradiations and dosimetry at the LLL rotating target neutron source

    International Nuclear Information System (INIS)

    MacLean, S.C.

    1977-01-01

    The DT fusion neutron irradiation of more than 90 samples during seven irradiation periods (beam-on time of more than 430.9 hours) is described. Experiments from 15 individuals representing six institutions are summarized. The numbers of UCID dosimetry reports detailing each of the irradiations is given

  17. Current situation for exoelectron dosimeters of BeO ceramic in neutron dosimetry

    International Nuclear Information System (INIS)

    Gammage, R.B.

    1977-01-01

    Much of the early enthusiasm for using exoelectron dosimeters (ceramic BeO Thermalox 995) in neutron dosimetry was predicted on the belief that the response to fast neutrons, relative to gamma rays, was 0.18 to 0.28 on a R/sub γ/ equiv/tissue rad n/sub f/ basis for neutron energies between 0.1 and 16 MeV. Pairs of BeO disks had to be used, one covered with a polyethylene radiator for producing recoil protons, and the other covered with Teflon. More recent studies indicated a considerably lower ratio of 0.11 for Health Physics Reactor Research fission neutrons. In the earlier work the BeO was coated with gold to enhance the surface conductivity during reading of the thermally stimulated exoelectron emission (TSEE). No metallic coating is now deemed to be necessary. Perhaps thermal neutron contamination of the fast neutron beams due to some thermalization within the hydrogenous radiator was sufficient to cause the high apparent fast neutron sensitivity via n, γ reactions. Whatever the cause, however, the lower value of 0.11 has caused a marked subsidence of enthusiasm in this technique of fast neutron monitoring

  18. Measurement of neutron and gamma absorbed doses in phantoms exposed to mixed fields

    International Nuclear Information System (INIS)

    Beraud-Sudreau, E.; Lemaire, G.; Maas, J.

    1985-01-01

    In order to study the dosimetric characteristics of PIN junctions, the absorbed doses measured by junctions and FLi7 in air and water phantoms were compared with the doses measured by classical neutron dosimetry in mixed fields. The validity of the experimental responses of PIN junctions being thus checked and established, neutron and gamma dose distributions in tissue equivalent plastic phantoms (plastinaut) and mammals (piglets) were evaluated as well as the absorbed dose distributions in the pig bone-marrow producing areas. By using correlatively a Monte-Carlo calculation method and applying some simplifying assumptions, the absorbed doses were derived from the spectrum of SILENE's neutrons at various depths inside a cubic water phantom and the results were compared with some from the literature [fr

  19. Neutron personal dosimetry in criticality accidents

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Mauricio, C.L.P.

    1996-01-01

    In the present work an innovating method is proposed to estimate the absorbed dose received by individuals irradiated with neutrons in an accident, even in the case that the victim is not using any kind of neutron dosemeter. The method combines direct measurements of 24 Na and 32 P activated in the human body. The calculation method was developed using data taken from previously published papers and experimental measurements. Other irradiations results in different neutron spectra prove the validity of the method here proposed. Using a whole body counter to measure 24 Na activity, it is possible to evaluate neutron absorbed doses in the order of 140 μ Gy of very soft (thermal) spectra. For fast neutron fields, the lower limit for neutron dose detection increases, but the present method continues to be very useful in accidents, with higher neutron doses. (author)

  20. Minutes of the 14th Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Program (LWR-PV-SDIP) meeting, October 1-5, 1984

    International Nuclear Information System (INIS)

    1984-01-01

    Topics discussed include: ASTM LWR standards; trend curves, PSF, and other test reactor metallurgical programs; PSF dosimetry and metallurgical capsule neutron and gamma characterization and metallurgical studies; PVS characterization program; other neutron fields; Surveillance Dosimetry Measurement Facility (SDMF) and perturbation studies; transport theory calculations; gamma field benchmarks and photo-reaction studies; and fission and non-fission sensor inventories and quality assurance

  1. Personnel dosimetry of fast neutrons by silver activation in nuclear emulsions

    International Nuclear Information System (INIS)

    Francois, H.; Heilmann, C.; Jung, M.; Kappler, A.; Oppel, R.; Demoulin, R.

    1982-01-01

    This neutron dosimetry method may be extended to the radiological monitoring of a large number of workers. It uses photographic emulsion, a detector with long-established properties. The reproducibility of the detection characteristics is guaranteed by industrial manufacture. The method has been thoroughly tested and is now sufficiently under control for the application stage to be contemplated. The activation method has shown moreover that the optical counting technique accounts for only half the signal available. Owing to its sensitivity, energy response from 100 keV onwards, capacity to measure the neutron and electromagnetic (γ or X) doses simultaneously and complete automation the method may now be considered ready for extensive use in radioprotection [fr

  2. Neutron dosimetry at commercial nuclear plants. Final report of Subtask B: dosimeter response

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, F.M.; Endres, G.W.R.; Brackenbush, L.W.

    1983-03-01

    As part of a larger program to evaluate personnel neutron dosimetry at commercial nuclear power plants, this study was designed to characterize neutron dosimeter responses inside the containment structure of commercial nuclear plants. In order to characterize those responses, dosimeters were irradiated inside containment at 2 pressurized water reactors and at pipe penetrations outside the biological shield at two boiling water reactors. The reactors were operating at full power during the irradiations. Measurements were also performed with electronic instruments, the tissue equivalent proportional counter (TEPC), and portable remmeters, SNOOPY, RASCAL and PNR-4.

  3. Neutron dosimetry at commercial nuclear plants. Final report of Subtask B: dosimeter response

    International Nuclear Information System (INIS)

    Cummings, F.M.; Endres, G.W.R.; Brackenbush, L.W.

    1983-03-01

    As part of a larger program to evaluate personnel neutron dosimetry at commercial nuclear power plants, this study was designed to characterize neutron dosimeter responses inside the containment structure of commercial nuclear plants. In order to characterize those responses, dosimeters were irradiated inside containment at 2 pressurized water reactors and at pipe penetrations outside the biological shield at two boiling water reactors. The reactors were operating at full power during the irradiations. Measurements were also performed with electronic instruments, the tissue equivalent proportional counter (TEPC), and portable remmeters, SNOOPY, RASCAL and PNR-4

  4. Field neutron spectrometer using 3He, TEPC, and multisphere detectors

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1991-01-01

    Since the last DOE Neutron Dosimetry Workshop, there have been a number of changes in radiation protection standards proposed by national and international advisory bodies. These changes include: increasing quality factors for neutrons by a factor of two, defining quality factors as a function of lineal energy rather than linear energy transfer (see ACCRUE-40; Joint Task Group 1986), and adoption of effective dose equivalent methodologies. In order to determine the effects of these proposed changes, it is necessary to know the neutron energy spectrum in the work place. In response to the possible adoption of these proposals, the Department of Energy (DOE) initiated a program to develop practical neutron spectrometry systems for use by health physicists. One part of this program was the development of a truly portable, battery operated liquid scintillator spectrometer using proprietary electronics developed at Lawrence Livermore National Laboratory (LLNL); this instrument will be described in the following paper. The second part was the development at PNL of a simple transportable spectrometer based on commercially available electronics. This open-quotes field neutron spectrometerclose quotes described in this paper is intended to be used over a range of neutron energies extending from thermal to 20 MeV

  5. Range and energy functions of interest in neutron dosimetry

    International Nuclear Information System (INIS)

    Bhatia, D.P.; Nagarajan, P.S.

    1978-01-01

    This report documents the energy and range functions generated and used in fast neutron interface dosimetry studies. The basic data of stopping power employed are the most recent. The present report covers a number of media mainly air, oxygen, nitrogen, polythene, graphite, bone and tissue, and a number of charged particles, namely protons, alphas, 9 Be, 11 B, 12 C, 13 C, 14 N and 16 O. These functions would be useful for generation of energy and range values for any of the above particles in any of the above media within +- 1% in any dosimetric calculations. (author)

  6. Small field electron beam dosimetry using MOSFET detector.

    Science.gov (United States)

    Amin, Md Nurul; Heaton, Robert; Norrlinger, Bern; Islam, Mohammad K

    2010-10-04

    The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becoming filmless in favor of electronic imaging, an alternate and readily available clinical dosimeter needs to be explored. We have studied the performance of MOSFET as a relative dosimeter in small field electron beams. The reproducibility, linearity and sensitivity of a high-sensitivity microMOSFET were investigated for clinical electron beams. In addition, the percent depth doses, output factors and profiles have been measured in a water tank with MOSFET and compared with those measured by an ion chamber for a range of field sizes from 1 cm diameter to 10 cm × 10 cm for 6, 12, 16 and 20 MeV beams. Similar comparative measurements were also per-formed with MOSFET and films in solid water phantom. The MOSFET sensitivity was found to be practically constant over the range of field sizes investigated. The dose response was found to be linear and reproducible (within ± 1% for 100 cGy). An excellent agreement was observed among the central axis depth dose curves measured using MOSFET, film and ion chamber. The output factors measured with MOSFET for small fields agreed to within 3% with those measured by film dosimetry. Overall results indicate that MOSFET can be utilized to perform dosimetry for small field electron beam.

  7. Applications of Bonner sphere detectors in neutron field dosimetry

    International Nuclear Information System (INIS)

    Awschalom, M.; Sanna, R.S.

    1983-09-01

    The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed

  8. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Yamamoto, Kazuyoshi; Torii, Yoshiya; Uchiyama, Junzo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Matsumura, Akira; Yamamoto, Tetsuya; Nose, Tadao [Tsukuba Univ., Tsukuba, Ibaraki (Japan); Nakagawa, Yoshinobu [National Sanatorium Kagawa-Children' s Hospital, Kagawa (Japan); Kageji, Teruyoshi [Tokushima Univ., Tokushima (Japan)

    2003-03-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal in the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System which can support to set the patient to an actual irradiation position swiftly and accurately. This report describes basic design of JCDS and functions in several processing, calculation methods, characteristics and performance of JCDS. (author)

  9. Neutron field characterization and dosimetry at the TRIUMF proton therapy facility

    International Nuclear Information System (INIS)

    Mukherjee, B.

    2002-01-01

    Full text: In 1972 the 500 MeV H' Cyclotron of the TRIUMF (Tri University Meson Factory) located in Vancouver, Canada became operational. Beside Meson Physics, high-energy protons of various energy and beam current levels from the TRIUMF Cyclotron are used for scientific research and biomedical applications. Recently, a 500 MeV proton beam from the cyclotron was used as the booster beam for the radioactive ion beam facility, ISAC (Isotope Separator Accelerator) and a second beam as primary irradiation source for the Proton Irradiation Facility (PIF). The major commercial applications of the PIF are the provision of high-energy proton beams for radiation hardness testing of electronic components used in space applications (NASA) and proton therapy of ocular tumors (British Columbia Proton Therapy Facility). The PIF vault was constructed within the main accelerator hall of the TRIUMF using stacks of large concrete blocks. An intense field of fast neutrons is produced during the interaction of high-energy proton beam with target materials, such as, beam stops, collimators and beam energy degraders. The leakage of such neutrons due to insufficient radiological shielding or through the shielding discontinuities may constitute a major share of the personnel radiation exposure of the radiation workers. The neutron energy distribution and dose equivalent near a lead beam stopper bombarded with 116 MeV and 65 MeV collimated proton beams at the Ocular Tumor irradiation facility were evaluated using a Bonner-Sphere Spectrometer and a REM counter respectively. The results were utilized to investigate efficacy of the existing radiological shielding of the PIF. This paper highlights experimental methods to analyze the high-energy accelerator produced neutron beam and basic guideline for the radiological shielding designs of irradiation vault of Proton Therapy facilities

  10. Lithium Blanket Module dosimetry measurements at the LOTUS 14-MeV neutron source facility

    International Nuclear Information System (INIS)

    Tsang, F.Y.; Leo, W.R.; Sahraoui, C.; Wuthrich, S.; Harker, Y.D.

    1986-01-01

    This paper describes the measurements and results of the dosimeter material reaction rates inside the Lithium Blanket Module (LBM) after irradiation by the LOTUS 14-MeV neutron source at the Ecole Polytechnique Federale de Lausanne. The measurement program has been designed to utilize sets of passive dosimeter materials in the form of foils and wires. The dosimetry materials reaction thresholds and interaction response ranges chosen for this series of measurements encompass the entire neutron spectra along the full length of the LBM fuel rods

  11. Analytical dosimetry for spontaneous tumor dogs receiving boron neutron capture therapy

    International Nuclear Information System (INIS)

    Wheeler, F.J.; Atkinson, C.A.; Gavin, P.R.

    1992-01-01

    The dog irradiation project of the Power Burst Facility/Boron Neutron Capture Therapy (PBF/BNCT) Program is administered by Washington State University (WSU) with analytical and physical dosimetry provided by the Idaho National Engineering Laboratory (INEL). One subtask of this project includes BNCT safety studies for dogs with spontaneously-occurring brain tumors. The boron compound (Na 2 B 12 H 11 SH or BSH) was administered and single irradiations performed using the epithermal-neutron beam at the Brookhaven Medical Research Reactor (BMRR). The main goal of the study was not to provide therapy, but to determine tumorcidal effect while administering a subtolerance dose to healthy tissue. Irradiation times were based on delivery of 19 Gy peak physical dose to the blood

  12. Assessment of neutronic parameter's uncertainties obtained within the reactor dosimetry framework: Development and application of the stochastic methods of analysis

    Energy Technology Data Exchange (ETDEWEB)

    Destouches, C.; Beretz, D. [Service de Physique Experimentale, CEA-CAD/DEN/DER/SPEx, Departement d' Etudes des Reacteurs, 13108 St-Paul lez Durance Cedex (France); Devictor, N. [Service d' Etude des Systemes Innovant, CEA-CAD/DEN/DER/SESI, Departement d' Etudes des Reacteurs, 13108 St-Paul lez Durance Cedex (France); Gregoire, G. [Service de Physique Experimentale, CEA-CAD/DEN/DER/SPEx, Departement d' Etudes des Reacteurs, 13108 St-Paul lez Durance Cedex (France)

    2006-07-01

    One of the main objectives of reactor dosimetry is the determination of the physical parameters characterizing the neutronic field in which the studied sample is irradiated. The knowledge of the associated uncertainties represents a significant stake for nuclear industry as shows the high uncertainty value of 15% (k=1) commonly allowed for the calculated neutron flux (E> 1 MeV) on the vessel and internal structures. The study presented in this paper aims at determining then reducing uncertainties associated with the reactor dosimetry interpretation process. After a brief presentation of the interpretation process, input data uncertainties identification and quantification are performed in particular with regard to covariances. Then uncertainties propagation is carried out and analyzed by deterministic and stochastic methods on a representative case. Finally, a Monte Carlo sensitivity study based on Sobol indices is achieved on a case leading to derive the most penalizing input uncertainties. This paper concludes rising improvement axes to be studied for the input data knowledge. It highlights for example the need for having realistic variance-covariance matrices associated with input data (cross sections libraries, neutron computation code's outputs, ...). Lastly, the methodology principle presented in this paper is enough general to be easily transposable for other measurements data interpretation processes. (authors)

  13. Dose-response curve for blood exposed to gamma-neutron mixed field by conventional cytogenetic method

    International Nuclear Information System (INIS)

    Brandao, Jose Odinilson de C.; Souza, Priscilla L.G.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F.; Calixto, Merilane S.; Santos, Neide

    2009-01-01

    There is increasing concern about airline crew members (about one million worldwide) are exposed to measurable neutrons doses. Historically, cytogenetic biodosimetry assays have been based on quantifying asymmetrical chromosome alterations (dicentrics, centric rings and acentric fragments) in mytogen-stimulated T-lymphocytes in their first mitosis after radiation exposure. Increased levels of chromosome damage in peripheral blood lymphocytes are a sensitive indicator of radiation exposure and they are routinely exploited for assessing radiation absorbed dose after accidental or occupational exposure. Since radiological accidents are not common, not all nations feel that it is economically justified to maintain biodosimetry competence. However, dependable access to biological dosimetry capabilities is completely critical in event of an accident. In this paper the dose-response curve was measured for the induction of chromosomal alterations in peripheral blood lymphocytes after chronic exposure in vitro to neutron-gamma mixes field. Blood was obtained from one healthy donor and exposed to two neutron-gamma mixed field from sources 241 AmBe (20 Ci) at the Neutron Calibration Laboratory (NCL-CRCN/NE-PE-Brazil). The evaluated absorbed doses were 0.2 Gy; 1.0 Gy and 2.5 Gy. The dicentric chromosomes were observed at metaphase, following colcemid accumulation and 1000 well-spread metaphase figures were analyzed for the presence of dicentrics by two experienced scorers after painted by giemsa 5%. Our preliminary results showed a linear dependence between radiations absorbed dose and dicentric chromosomes frequencies. Dose-response curve described in this paper will contribute to the construction of calibration curve that will be used in our laboratory for biological dosimetry. (author)

  14. Dose-response curve for blood exposed to gamma-neutron mixed field by conventional cytogenetic method

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Jose Odinilson de C.; Souza, Priscilla L.G.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F., E-mail: jodinilson@cnen.gov.b, E-mail: fflima@cnen.gov.b, E-mail: jasantos@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Calixto, Merilane S.; Santos, Neide, E-mail: santos_neide@yahoo.com.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Genetica

    2009-07-01

    There is increasing concern about airline crew members (about one million worldwide) are exposed to measurable neutrons doses. Historically, cytogenetic biodosimetry assays have been based on quantifying asymmetrical chromosome alterations (dicentrics, centric rings and acentric fragments) in mytogen-stimulated T-lymphocytes in their first mitosis after radiation exposure. Increased levels of chromosome damage in peripheral blood lymphocytes are a sensitive indicator of radiation exposure and they are routinely exploited for assessing radiation absorbed dose after accidental or occupational exposure. Since radiological accidents are not common, not all nations feel that it is economically justified to maintain biodosimetry competence. However, dependable access to biological dosimetry capabilities is completely critical in event of an accident. In this paper the dose-response curve was measured for the induction of chromosomal alterations in peripheral blood lymphocytes after chronic exposure in vitro to neutron-gamma mixes field. Blood was obtained from one healthy donor and exposed to two neutron-gamma mixed field from sources {sup 241}AmBe (20 Ci) at the Neutron Calibration Laboratory (NCL-CRCN/NE-PE-Brazil). The evaluated absorbed doses were 0.2 Gy; 1.0 Gy and 2.5 Gy. The dicentric chromosomes were observed at metaphase, following colcemid accumulation and 1000 well-spread metaphase figures were analyzed for the presence of dicentrics by two experienced scorers after painted by giemsa 5%. Our preliminary results showed a linear dependence between radiations absorbed dose and dicentric chromosomes frequencies. Dose-response curve described in this paper will contribute to the construction of calibration curve that will be used in our laboratory for biological dosimetry. (author)

  15. Criticality accident dosimetry with ESR spectroscopy.

    Science.gov (United States)

    d'Errico, F; Fattibene, P; Onori, S; Pantaloni, M

    1996-01-01

    The suitability of the ESR alanine and sugar detectors for criticality accident dosimetry was experimentally investigated during an intercomparison of dosimetry techniques. Tests were performed irradiating detectors both free-in-air and on-phantom during controlled critcality excursions at the SILENE reactor in Valduc, France. Several grays of absorbed dose were imparted in neutron gamma-ray fields of various relative intensities and spectral distributions. Analysed results confirmed the potential of these systems which can immediately provide an acute dose assessment with an average underestimate of 30%in the various fields. This performance allows for the screening of severely exposed individuals and meets the IAEA recommendations on the early estimate of accident absorbed doses.

  16. Reactor IPEN/MB-01 dosimetry using TLDs

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tássio A.; Siqueira, Paulo T.D.; Yoriyaz, Hélio, E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energética s e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    This paper is a preliminary study on the use of reactor IPEN/MB-01 as standard radiation source for mixed field dosimetry studies. As a first step on this attempt, simulations and experiments, evaluating the neutron and gamma field distributions, were performed and compared. TLDs are widely employed in dose measurements and the TLD 100 / TLD 700 pair conforms with ICRU recommendations for mixed field dosimetry. In this study, TLD irradiations were performed in the IPEN/MB-01 nuclear reactor. IPEN/MB-01 reactor is zero power reactor widely used to perform reactor physics experiments. Its neutron flux distribution is well known for a variety of reactor core configurations. However, the photon fluxes are unknown. A series of experiments with TLD 100 and TLD 700 were performed for two different core configurations (rectangular and cylindrical with a central flux trap). Simulations with MCNP5 for these two configurations were also done, and neutron and gamma fluxes distributions along the core were computed. The responses of TLD 100 and TLD 700 were compared with simulated fluxes and showing a good agreement between them. This paper presents the results of the experiments done so far given the status of the study under way in order to couple IPEN/MB-01 and TLD 100 / 700 pair into a mixed field calibration methodology. (author)

  17. Monte Carlo based dosimetry and treatment planning for neutron capture therapy of brain tumors

    International Nuclear Information System (INIS)

    Zamenhof, R.G.; Brenner, J.F.; Wazer, D.E.; Madoc-Jones, H.; Clement, S.D.; Harling, O.K.; Yanch, J.C.

    1990-01-01

    Monte Carlo based dosimetry and computer-aided treatment planning for neutron capture therapy have been developed to provide the necessary link between physical dosimetric measurements performed on the MITR-II epithermal-neutron beams and the need of the radiation oncologist to synthesize large amounts of dosimetric data into a clinically meaningful treatment plan for each individual patient. Monte Carlo simulation has been employed to characterize the spatial dose distributions within a skull/brain model irradiated by an epithermal-neutron beam designed for neutron capture therapy applications. The geometry and elemental composition employed for the mathematical skull/brain model and the neutron and photon fluence-to-dose conversion formalism are presented. A treatment planning program, NCTPLAN, developed specifically for neutron capture therapy, is described. Examples are presented illustrating both one and two-dimensional dose distributions obtainable within the brain with an experimental epithermal-neutron beam, together with beam quality and treatment plan efficacy criteria which have been formulated for neutron capture therapy. The incorporation of three-dimensional computed tomographic image data into the treatment planning procedure is illustrated

  18. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    International Nuclear Information System (INIS)

    Kumada, Hiroaki; Torii, Yoshiya

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  19. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    CERN Document Server

    Kumada, H

    2002-01-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to ...

  20. Status of neutron dosimetry cross sections

    International Nuclear Information System (INIS)

    Griffin, P.J.; Kelly, J.G.

    1992-01-01

    Several new cross section libraries, such as ENDF/B-VI(release 2), IRDF-90,JEF-2.2, and JENDL-3 Dosimetry, have recently been made available to the dosimetry community. the Sandia National Laboratories (SNL) Radiation Metrology Laboratory (RML) has worked with these libraries since pre-release versions were available. this paper summarizes the results of the intercomparison and testing of dosimetry cross sections. As a result of this analysis, a compendium of the best dosimetry cross sections was assembled from the available libraries for use within the SNL RML. this library, referred to as the SNLRML Library, contains 66 general dosimetry sensors and 3 special dosimeters unique to the RML sensor inventory. The SNLRML cross sections have been put into a format compatible with commonly used spectrum determination codes

  1. Individual monitoring dosimetry in Europe

    International Nuclear Information System (INIS)

    Menzel, H.G.

    1991-01-01

    This report discusses the various types of individual monitoring systems presently in use within the European community and neutron dosimetry research being coordinated by the EURADOS working group. Research is currently being conducted on nuclear track dosimeters, primarily with CR-39 (TM), and TLD-albedo dosimeters. Studies are being conducted on the energy and angular response of each type of dosimeter. Because the response of dosimeters depends on the energy of the neutrons, it is necessary to have spectral information to accurately assess the dose. Neutron energy spectrum measurements are being performed in typical work place environments. Work is also progressing on development of calibration sources which will be representative of the neutron energy spectrum found in typical neutron exposure situations. This work utilizes 14 MeV neutrons incident on a uranium block with various other filters. Research is also continuing on neutron dosimetry using tissue equivalent proportional counters and microdosimetric techniques. The results of intercomparisons between several different instruments are discussed. In addition to personnel dosimetry, these systems are being used to record the dose to passengers and flight crews aboard commercial aircraft

  2. Study on neutron dosimetry in JNC Tokai Works

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan). Tokai Works

    2003-03-01

    The author developed the neutron reference calibration fields using a {sup 252}Cf standard source surrounded with PMMA (polymethylmethacrylates) moderators at the Japan Nuclear Cycle Development Institute (JNC), Tokai Works. The moderators are concentric, annular cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the {sup 252}Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO{sub 2}-UO{sub 2} mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments. (author)

  3. Neutron response study

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Fix, J.J.; Thorson, M.R.; Nichols, L.L.

    1981-01-01

    Neutron response of the albedo type dosimeter is strongly dependent on the energy of the incident neutrons as well as the moderating material on the backside of the dosimeter. This study characterizes the response of the Hanford dosimeter for a variety of neutron energies for both a water and Rando phantom (a simulated human body consisting of an actual human skeleton with plastic for body muscles and certain organs). The Hanford dosimeter response to neutrons of different energies is typical of albedo type dosimeters. An approximate two orders of magnitude difference in response is observed between neutron energies of 100 keV and 10 MeV. Methods were described to compensate for the difference in dosimeter response between a laboratory neutron spectrum and the different spectra encountered at various facilities in the field. Generally, substantial field support is necessary for accurate neutron dosimetry

  4. Textbook of dosimetry. 4. ed.

    International Nuclear Information System (INIS)

    Ivanov, V.I.

    1999-01-01

    This textbook of dosimetry is devoted to the students in physics and technical physics of high education institutions, confronted with different application of atomic energy as well as with protection of population and environment against ionizing radiations. Atomic energy is highly beneficial for man but unfortunately incorporates potential dangers which manifest in accidents, the source of which is either insufficient training of the personnel, a criminal negligence or insufficient reliability of the nuclear facilities. The majority of the incident and accident events have had as origin the personnel errors. This was the case with both the 'Three Miles Island' (1979) and Chernobyl (1986) NPP accidents. The dosimetry science acquires a vital significance in accident situations since the data obtained by its procedures are essential in choosing the correct immediate actions, behaviour tactics, orientation of liquidation of accident consequences as well as in ensuring the health of population. An important accent is placed in this manual on clarification of the nature of physical processes taken place in dosimetric detectors, in establishing the relation between radiation field characteristics and the detector response as well as in defining different dosimetric quantities. The terminology and the units of physical quantities is based on the international system of units. The book contains the following 15 chapters: 1. Ionizing radiation field; 2. Radiation doses; 3. Physical bases of gamma radiation dosimetry; 4. Ionization dosimetric detectors; 5. Semiconductor dosimetric detectors; 6. Scintillation detection in the gamma radiation dosimetry; 7. Luminescent methods in dosimetry; 8. The photographic and chemical methods of gamma radiation dosimetry; 9. Neutron dosimetry; 10. Dosimetry of high intensity radiation; 11. Dosimetry of high energy Bremsstrahlung; 12. Measurement of the linear energy transfer; 13. Microdosimetry; 14. Dosimetry of incorporated

  5. Intercomparison of radiation protection devices in a high-energy stray neutron field. Part III: Instrument response

    CERN Document Server

    Silari, M; Beck, P; Bedogni, R; Cale, E; Caresana, M; Domingo, C; Donadille, L; Dubourg, N; Esposito, A; Fehrenbacher, G; Fernández, F; Ferrarini, M; Fiechtner, A; Fuchs, A; García, M J; Golnik, N; Gutermuth, F; Khurana, S; Klages, Th; Latocha, M; Mares, V; Mayer, S; Radon, T; Reithmeier, H; Rollet, S; Roos, H; Rühm, W; Sandri, S; Schardt, D; Simmer, G; Spurný, F; Trompier, F; Villa-Grasa, C; Weitzenegger, E; Wiegel, B; Wielunski, M; Wissmann, F; Zechner, A; Zielczyński, M

    2009-01-01

    The European Commission has funded within its 6th Framework Programme a three-year project (2005–2007) called CONRAD, COordinated Network for RAdiation Dosimetry. The organizational framework for this project was provided by the European radiation Dosimetry Group EURADOS. Work Package 6 of CONRAD dealt with “complex mixed radiation fields at workplaces” and in this context it organised a benchmark exercise, which included both measurements and calculations, in a stray radiation field at a high-energy particle accelerator at GSI, Germany. The aim was to intercompare the response of several types of active detectors and passive dosemeters in a well-characterised workplace field. The Monte Carlo simulations of the radiation field and the experimental determination of the neutron spectra with various Bonner Sphere Spectrometers are discussed in Rollet et al. (2008) and in Wiegel et al. (2008). This paper focuses on the intercomparison of the response of the dosemeters in terms of ambient dose equivalent. Th...

  6. Introduction [International Reactor Dosimetry File 2002 (IRDF-2002)

    International Nuclear Information System (INIS)

    Paviotti-Corcuera, R.; Zolnay, E.M.

    2006-01-01

    service life of reactor pressure vessels. Accurate cross-section data are also essential in other neutron metrology applications such as boron neutron capture therapy, therapeutic uses of medical radioisotopes, nuclear physics measurements and reactor safety studies. The work undertaken within the project included the following tasks: Detailed analyses and comparisons of the cross-section data and the related uncertainty information present in different reactor dosimetry and general purpose libraries, including IRDF-90.2, JENDL/D-99 and 2 RRDF-98, and the most recent releases of ENDF/B-VI, JEFF-3.0 and CENDL-2. Comparisons were also made of the calculated integral cross section data with experimental reaction rates in standard neutron fields; Selection of the best quality cross-section information based on the above comparisons; Evaluation and testing of new reaction cross-sections, as requested by the reactor dosimetry community for extension of the library; Selection of evaluated and up to date nuclear decay characteristics and isotopic abundances; Testing of important dosimetry cross-sections in reference benchmark neutron fields. Although the release of IRDF-2002 and publication of the related documentation occurred after 2002, participants attending the second Technical Meeting decided to retain the title IRDF-2002, since the library has been referred to as this in the open literature. A CD-ROM containing the full contents of IRDF-2002 accompanies this report. Updated versions of this library will also be released by the IAEA on CD-ROM (author)

  7. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed

  8. Simulated workplace neutron fields

    International Nuclear Information System (INIS)

    Lacoste, V.; Taylor, G.; Rottger, S.

    2011-01-01

    The use of simulated workplace neutron fields, which aim at replicating radiation fields at practical workplaces, is an alternative solution for the calibration of neutron dosemeters. They offer more appropriate calibration coefficients when the mean fluence-to-dose equivalent conversion coefficients of the simulated and practical fields are comparable. Intensive Monte Carlo modelling work has become quite indispensable for the design and/or the characterization of the produced mixed neutron/photon fields, and the use of Bonner sphere systems and proton recoil spectrometers is also mandatory for a reliable experimental determination of the neutron fluence energy distribution over the whole energy range. The establishment of a calibration capability with a simulated workplace neutron field is not an easy task; to date only few facilities are available as standard calibration fields. (authors)

  9. CaSO{sub 4}:Dy microphosphor for thermal neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bhadane, Mahesh S. [Microtron Accelerator Laboratory, Department of Physics, Savitribai Phule Pune University, Pune 411007 (India); Mandlik, Nandkumar [Department of Physics, Fergusson College, Savitribai Phule Pune University, Pune 411007 (India); Patil, B.J. [Department of Physics, Abasaheb Garware College, Pune 411004 (India); Dahiwale, S.S.; Sature, K.R.; Bhoraskar, V.N. [Microtron Accelerator Laboratory, Department of Physics, Savitribai Phule Pune University, Pune 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Microtron Accelerator Laboratory, Department of Physics, Savitribai Phule Pune University, Pune 411007 (India)

    2016-02-15

    Dysprosium-doped calcium sulphate (CaSO{sub 4}:Dy) microphosphor was synthesized by acid re-crystallization method and its thermoluminescence (TL) properties irradiated with thermal neutrons was studied. Structural and morphological characteristics have been studied using X-ray diffraction and SEM which mainly exhibits a orthorhombic structure with particle size of 200 to 250 µm. Moreover, thermal neutron dosimetric characteristics of the microphosphor such as thermoluminescence glow curve, TL dose–response have been studied. This microphosphor powder represents a TL glow peak (T{sub max}) centered at around 240 °C. The TL response of CaSO{sub 4}:Dy microphosphor as a function of thermal neutron fluence is observed to be very linear upto the fluence of 52×10{sup 11} n/cm{sup 2} and further saturates. In addition, TL glow curves were deconvoluted by computerized glow curve deconvolution (CGCD) method and corresponding trapping parameters have been determined. It has been found that for every deconvoluted peak there is change in the order of kinetics. Overall, the experimental results show that the CaSO{sub 4}:Dy microphosphor can have potential to be an effective thermal neutron dosimetry. - Highlights: • Acid-recrystallization method is used to prepare CaSO{sub 4}:Dy microphosphor • CaSO{sub 4}:Dy phosphor irradiated thermal neutrons for dosimetric application. • TL response curve showed to be a perfect linear. • Trapping parameters has been calculated using CGCD curve fitting.

  10. Assessment and comparison of different multigroup neutron cross section libraries for dosimetry purposes

    International Nuclear Information System (INIS)

    Erradi, L.; Karouani, K.

    1994-01-01

    Many multigroup neutron cross section libraries have been processed from basic evaluated nuclear data for use in neutron dosimetry, reactor shielding calculation and in the development of fusion reactors. Most of these libraries have been tested only for fission spectra and were not validated for fusion spectra. Fifteen of these libraries such as DOSCROS84, IRDF85 and ENDFB5 have been used along with the neutron spectra unfolding code SAND II to evaluate about fifteen threshold detector saturated activities. The comparison between these computed activities and the measured ones of a set of foils placed in different places along the axis of a paraffin cylinder and irradiated by 14 MeV neutrons generated by a D-T source, hence giving rise to complex spectra, leads to different types of discrepancies. The analysis of these discrepancies allows to select from these libraries the ones that can be recommended. 1 fig., 4 refs. (author)

  11. The neutron and low-energy gamma operational dosimetry in Melox plant

    International Nuclear Information System (INIS)

    Devita, A.D.

    2006-01-01

    M.E.L.O.X., subsidiary of A.R.E.V.A., produce M.O.X. fuels, a mixture of uranium and plutonium oxides. With the use in the process of plutonium oxide, there is a risk of external exposure to neutrons and low -energy gamma rays. By their characteristics, both these types of radiation are difficult to measure. The difficulty in measuring neutron doses lies in the fact that the fluence -to-dose equivalent conversion factor varies with the neutron energy level. In low -energy gamma (between 20 and 60 keV) dose measurement, the problem is detection using an electronic system. Just some years ago, very few industrial players were tempted to develop dosimeters in these areas in view of the poor demand and market prospects. Furthermore, radiation protection specialists needed a highly functional and robust direct reading dosimeters or, in other words, a device that was simple, reliable, inexpensive, small, and quick and easy to use in a wide range of working environments that could vary in terms of both the workstation and external exposure. In addition, at sites such as Melox, where company employees work alongside personnel from outside companies, the same types of dosimeters must be used so that dose -related data can be managed globally in one data base. Two technical solutions are available for neutron operational dosimetry - spectrometer-dosimeters and calibration dosimeters. Melox has opted for the use of calibration dosimeters. The reasons for this choice (technical, financial and organizational criteria) are given in this presentation. Before and during the various campaigns of M.O.X. fuels, the spectral characteristics relating to neutron fluence at different workstations and representative of personnel exposure levels were determined. A reference spectrometer was then used to determine the transfer function between fluence and dose in order to calibrate passive and operational dosimeters appropriately.The methodology to be set up should guarantee good

  12. Recent developments in neutron dosimetry and radiation damage calculations for fusion-materials studies

    International Nuclear Information System (INIS)

    Greenwood, L.R.

    1983-01-01

    This paper is intended as an overview of activities designed to characterize neutron irradiation facilities in terms of neutron flux and energy spectrum and to use these data to calculate atomic displacements, gas production, and transmutation during fusion materials irradiations. A new computerized data file, called DOSFILE, has recently been developed to record dosimetry and damage data from a wide variety of materials test facilities. At present data are included from 20 different irradiations at fast and mixed-spectrum reactors, T(d,n) 14 MeV neutron sources, Be(d,n) broad-spectrum sources, and spallation neutron sources. Each file entry includes activation data, adjusted neutron flux and spectral data, and calculated atomic displacements and gas production. Such data will be used by materials experimenters to determine the exposure of their samples during specific irradiations. This data base will play an important role in correlating property changes between different facilities and, eventually, in predicting materials performance in fusion reactors. All known uncertainties and covariances are listed for each data record and explicit references are given to nuclear decay data and cross sections

  13. Dosimetry-adjusted reactor physics parameters for pressure vessel neutron exposure assessment

    International Nuclear Information System (INIS)

    McElroy, W.N.; Kellogg, L.S.

    1988-01-01

    The ASTM E706 master matrix standard describes a series of 20 American Society for Testing and Materials (ASTM) standard practices, guides, and methods for use in the prediction of neutron-induced changes in light water reactor (LWR) pressure vessel (PV) and support structure steels throughout a PV's service life. Some of these are existing ASTM standards, some are ASTM standards that have been modified, and some are new ASTM standards. These standards are periodically revised to assume their applicability during the 40-yr (32 effective full-power years) design license period for a nuclear power plant. They are now under review by two new ASTM plant life extension task groups: E10.05.11 on physics dosimetry and E10.02.11 on metallurgy. A brief review on the current application of these standards and a discussion of the status of work to verify the accuracy of derived physics-dosimetry parameter values is presented in this paper

  14. Personnel dosimetry methods introduced in the Czechoslovak national laboratories

    International Nuclear Information System (INIS)

    Trousil, J.; Singer, J.; Kokta, L.; Prouza, Z.

    1979-01-01

    Personnel dosimetry methods are described that were developed in the Institute for Research, Production and Application of Radioisotopes and that have been or will be introduced in the national personnel dosimetry service. In Czechoslovakia, workers exposed to a radiation risk are divided into two groups, according to the level of the risk. The criterion is the possibility of exceeding one tenth of the MPD. For the higher risk group, a complex dose meter is usually used for dosimetry of photon and beta radiation; it contains a film dose meter and a radiothermoluminescent (RTL) glass dose meter. The RTL glass dose meter also serves as an accident dose meter. For neutron dosimetry, a dose meter comprising a solid-state track detector in combination with fissionable foils has been introduced. For accident dosimetry, a silicon diode of Czechoslovak production is used. For the lower risk group, only the introduction of an RTL dose meter is foreseen. There will be a three month control period; for neutron dosimetry, the track detector in combination with fissionable foils is retained. For measurements of hand doses, a themoluminescent ring dose meter has been introduced. The dose meters are described, giving information on the types of detectors employed, measurement techniques and descriptions of the basic characteristics of the instruments, their basic dosimetric parameters and the dose and energy ranges which can be measured. The results of international comparisons are presented; these have served to confirm the measurement precision. In conclusion, some questions of dose-meter calibration are summarized, and the problems of dose measurement in mixed fields of neutrons and gamma rays are discussed. (author)

  15. A practical proposal for neutron dosimetry in radiation protection

    International Nuclear Information System (INIS)

    Busuoli, G.; Pelliccioni, M.

    1985-01-01

    The innovations recommended in ICRP Publication 26 give rise to questionable consequences for current radiation protection practice. One of the most efficient is a proliferation of quantities for external exposure, the so called ''operational quantities'', devoid of any physical basis and scientifically undesirable. This risks undermining the unitary order given to the formulation of the limits. Moreover, as soon as an agreement is reached, then most of the instrumentation used at present should be replaced or modified. In the case of neutron dosimetry, at the moment, changes would be inappropriate. This is because one must take into account the results from the reassessment of the doses received by Japanese who were exposed at Hiroshima and Nagasaki, and the recent rumours about an increase of the quality factor at low doses. While awaiting further reflection on the matter, the way to continue to use the most popular neutron environmental instrument, the rem-counter is explained. The proposed solution, which is as open to question as any other, should at least allow considerable economical advantages and secure the continuity of current practice. (author)

  16. The response of the BTI bubble detectors in mixed gamma-neutron workplace fields

    International Nuclear Information System (INIS)

    Vanhavere, F.; Coeck, M.; Lievens, B.; Reginatto, M.

    2005-01-01

    Full text: Bubble detectors have become a mature technology and are used as neutron dosemeters in a wide range of applications. At the SCK-CEN and Belgonucleaire they are used as official personal neutron dosemeter for the personnel. Two types are commercially available from Bubble Technology Industries: the BD-PND, which has a neutron energy threshold of around 100 keV, and the BDT, which is mainly sensitive to thermal neutrons. At Belgonucleaire only the BD-PND is worn, and the results are corrected with a site specific factor. At the SCK-CEN both the BD-PND and BDT are worn and a combination of both results is applied for the dose records. In the EC project EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields), a whole range of neutron dosemeters were irradiated in workplace fields in nuclear installations in Europe, including both types of bubble detectors. The bubble detectors were exposed on a phantom with different angles towards the reference directions in the workplace fields. We will report the bubble detectors' results in the simulated workplace fields at Cadarache (CANEL and Sigma), in the workplaces at Kruemmel (boiling water reactor, transport cask), at Mol (Venus research reactor SCK-CEN, MOX-fuel facility Belgonucleaire) and Ringhals (pressurized water reactor, transport cask). The responses of the bubble detectors and the combination of both will be compared to the reference values determined with Bonner Spheres and a novel directional spectrometer. The dosemeter readings were checked for consistency by folding the dosemeter response functions with the corresponding workplace fluence spectra in the same workplace. (author)

  17. Reactor neutron dosimetry

    International Nuclear Information System (INIS)

    Najzer, M.; Pauko, M.; Glumac, B.; Acquah, I.N.; Moskon, F.

    1977-01-01

    An analysis of requirements and possibilities for experimental neutron spectrum determination during the reactor pressure vessel surveil lance programme is given. Fast neutron spectrum and neutron dose rate were measured in the Fast neutron irradiation facility of our TRIGA reactor. It was shown that the facility can be used for calibration of neutron dosimeters and for irradiation of samples sensitive to neutron radiation. The investigation of the unfolding algorithm ITER was continued. Based on this investigations are two specialized unfolding program packages ITERAD and ITERGS written this year. They are able to unfold data from activation detectors and NaI(T1) gamma spectrometer respectively

  18. Field dosimetry on sterilization area of medical-hospitable materials

    International Nuclear Information System (INIS)

    Mariano, C.S.T.P.; Campos, L.L.

    1992-01-01

    The calcium sulfate doped with dysprosium, used in high dose dosimetry by electron paramagnetic resonance (EPR), is studied on field dosimetry for medical-hospitable materials sterilization. The calibration curves of EPR signal in function of absorbed dose in air and the thermal decay of EPR signal at room temperature are also presented. (C.G.C)

  19. Distributions of neutron and gamma doses in phantom under a mixed field

    International Nuclear Information System (INIS)

    Beraud-Sudreau, E.

    1982-06-01

    A calculation program, based on Monte Carlo method, allowed to estimate the absorbed doses relatives to the reactor primary radiation, in a water cubic phantom and in cylindrical phantoms modelized from tissue compositions. This calculation is a theoretical approach of gamma and neutron dose gradient study in an animal phantom. PIN junction dosimetric characteristics have been studied experimentally. Air and water phantom radiation doses measured by PIN junction and lithium 7 fluoride, in reactor field have been compared to doses given by dosimetry classical techniques as tissue equivalent plastic and aluminium ionization chambers. Dosimeter responses have been employed to evaluate neutron and gamma doses in plastinaut (tissue equivalent plastic) and animal (piglet). Dose repartition in the piglet bone medulla has been also determined. This work has been completed by comparisons with Doerschell, Dousset and Brown results and by neutron dose calculations; the dose distribution related to lineic energy transfer in Auxier phantom has been also calculated [fr

  20. Consistency between data from the ENDF/B-V dosimetry file and corresponding experimental data for some fast neutron reference spectra

    International Nuclear Information System (INIS)

    Nolthenius, H.J.; Zijp, W.L.

    1981-11-01

    Results are given of a study on the consistency between 'integral' and 'differential' cross sections data for four benchmark neutron spectra and 36 neutron reactions of importance for reactor neutron metrology. The energy dependent cross section data and their uncertainty data are obtained from the ENDF/B-V dosimetry file. The reactions have been considered with respect to the following quantities: 1. the precision of the averaged cross sections, for a specified spectrum; 2. the discrepancy between the measured and the calculated average cross section values; 3. the consistency between the measured and calculated average cross section values, described by the chi 2 -parameter. It was possible to take into account the available cross section covariance information present in the ENDF/B-V dosimetry file. Covariance information on the benchmark flux density spectra was not taken into account in this study

  1. Applied physics of external radiation exposure dosimetry and radiation protection

    CERN Document Server

    Antoni, Rodolphe

    2017-01-01

    This book describes the interaction of living matter with photons, neutrons, charged particles, electrons and ions. The authors are specialists in the field of radiation protection. The book synthesizes many years of experiments with external radiation exposure in the fields of dosimetry and radiation shielding in medical, industrial and research fields. It presents the basic physical concepts including dosimetry and offers a number of tools to be used by students, engineers and technicians to assess the radiological risk and the means to avoid them by calculating the appropriate shields. The theory of radiation interaction in matter is presented together with empirical formulas and abacus. Numerous numerical applications are treated to illustrate the different topics. The state of the art in radiation protection and dosimetry is presented in detail, especially in the field of simulation codes for external exposure to radiation, medical projects and advanced research. Moreover, important data spread in differ...

  2. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Otto, T.

    1997-01-01

    In 1996, the Dosimetry and Calibration Section was, as in previous years, mainly engaged in routine tasks: the distribution of over 6000 dosimeters (with a total of more than 10,000 films) every two months and the calibration of about 900 fixed and mobile instruments used in the radiation survey sections of RP group. These tasks were, thanks to an experienced team, well mastered. Special efforts had to be made in a number of areas to modernize the service or to keep it in line with new prescriptions. The Individual Dosimetry Service had to assure that CERN's contracting firms comply with the prescriptions in the Radiation Safety Manual (1996) that had been inspired by the Swiss Ordinance of 1994: Companies must file for authorizations with the Swiss Federal Office for Public Health requiring that in every company an 'Expert in Radiation Protection' be nominated and subsequently trained. CERN's Individual Dosimetry Service is accredited by the Swiss Federal Authorities and works closely together with other, similar services on a rigorous quality assurance programme. Within this framework, CERN was mandated to organize this year the annual Swiss 'Intercomparison of Dosimeters'. All ten accredited dosimetry services - among others those of the Paul Scherrer Institute (PSI) in Villigen and of the four Swiss nuclear power stations - sent dosimeters to CERN, where they were irradiated in CERN's calibration facility with precise photon doses. After return to their origin they were processed and evaluated. The results were communicated to CERN and were compared with the originally given doses. A report on the results was subsequently prepared and submitted to the Swiss 'Group of Experts on Personal Dosimetry'. Reference monitors for photon and neutron radiation were brought to standard laboratories to assure the traceability of CERN's calibration service to the fundamental quantities. For photon radiation, a set of ionization chambers was calibrated in the reference field

  3. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

    International Nuclear Information System (INIS)

    Mangueira, Thyago Fressatti

    2009-01-01

    In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams. (author)

  4. Neutron monitoring for radiological protection

    International Nuclear Information System (INIS)

    Gibson, J.A.B.

    1985-01-01

    Neutron monitoring is a subject of increasing general interest and considerable attention is being paid to the development of improved techniques and methods for neutron monitoring. The Agency, therefore, considered it important to prepare a guide on the subject of neutron monitoring for radiation protection purposes. The present Manual is intended for those persons or authorities in Member States, particularly developing countries, who are responsible for the organization of neutron monitoring programmes and practical neutron monitoring. This Manual consequently, deals with topics such as neutron dosimetry, sources of neutrons and neutron detection as well as field instruments and operational systems used in this context

  5. Verification of the computational dosimetry system in JAERI (JCDS) for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Kumada, H; Yamamoto, K; Matsumura, A; Yamamoto, T; Nakagawa, Y; Nakai, K; Kageji, T

    2004-01-01

    Clinical trials for boron neutron capture therapy (BNCT) by using the medical irradiation facility installed in Japan Research Reactor No. 4 (JRR-4) at Japan Atomic Energy Research Institute (JAERI) have been performed since 1999. To carry out the BNCT procedure based on proper treatment planning and its precise implementation, the JAERI computational dosimetry system (JCDS) which is applicable to dose planning has been developed in JAERI. The aim of this study was to verify the performance of JCDS. The experimental data with a cylindrical water phantom were compared with the calculation results using JCDS. Data of measurements obtained from IOBNCT cases at JRR-4 were also compared with retrospective evaluation data with JCDS. In comparison with phantom experiments, the calculations and the measurements for thermal neutron flux and gamma-ray dose were in a good agreement, except at the surface of the phantom. Against the measurements of clinical cases, the discrepancy of JCDS's calculations was approximately 10%. These basic and clinical verifications demonstrated that JCDS has enough performance for the BNCT dosimetry. Further investigations are recommended for precise dose distribution and faster calculation environment

  6. Neutron spectrometry for protection dosimetry at very low levels

    International Nuclear Information System (INIS)

    Bardell, A.G.; Thomas, D.J.

    1996-01-01

    Dose limits for exposure of members of the public are significantly lower than those for designated radiation workers. The new ICRP 60 recommendation for critical groups of the general public is an effective dose limit of 1 mSv per year which requires a measurement capability at levels down to about 100 nSv h - 1. Radiation protection dosimetry for neutrons at these levels is problematical, nevertheless, operators of nuclear sites are still required to demonstrate acceptably low radiation levels in areas accessible to the public. In addition to the known poor dose equivalent response of available dosemeters, there is an added problem at low levels of inadequate sensitivity. Personal dosemeters are certainly not sufficiently sensitive, and the sensitivity of area survey instruments is such that they can only be used in integral mode Even then, the statistical uncertainties are likely to be large. One further problem concerns the quantity measured. Survey instruments are designed to measure the operational quantity ambient dose equivalent, H*(10), which always tends to be an overestimate of the present limiting quantity effective dose equivalent. If in any situation exposure is near the limit, an estimate of H*(10) may not be sufficient to prove conclusively that levels are less than the statutory limit, and a direct estimate of effective dose equivalent may need to be made. The only way of estimating effective dose equivalent is via an absolute spectral measurement. From such a spectrum any relevant dosimetric quantity can be estimated via tabulated fluence to dose equivalent conversion factors. (Certain quantities also require information about the angular dependence of the field - see later text). Spectrometry at such low neutron fluence levels is difficult, however, there is one instrument available which can perform the required measurements, and this is a well characterised Bonner sphere (BS) set. (author)

  7. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Torii, Yoshiya [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  8. Solid-state track recorder neutron dosimetry in the Three-Mile Island Unit-2 reactor cavity

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Ruddy, F.H.; Preston, C.C.; McElroy, W.N.

    1985-04-01

    Solid-state track recorder (SSTR) neutron dosimetry has been conducted in the Three-Mile Island Unit (TMI-2) reactor cavity (i.e., the annular gap between the pressure vessel and the biological shield) for nondestructive assessment of the fuel distribution. Two axial stringers were deployed in the annular gap with 17 SSTR dosimeters located on each stringer. SSTR experimental results reveal that neutron streaming, upward from the bottom of the reactor cavity region, dominates the observed neutron intensity. These absolute thermal neutron flux observations are consistent with the presence of a significant amount of fuel debris lying at the bottom of the reactor vessel. A conservative lower bound estimated from these SSTR data implies that there are at least 2 tonnes of fuel, which is roughly 4 fuel assemblies, at the bottom of the vessel. The existence of significant neutron streaming also explains the high count rate observed with the source range monitors (SRMs) that are located in the TMI-2 reactor cavity

  9. Experimental verification of a new neutron spectrometer for environmental dosimetry and area; Verficiacion experimental de un nuevo espectrometro de neutrones para dosimetria ambiental y de area

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Ros, J. M.; Romero, A.; Begogini, R.; Esposito, A.; Moraleda, M.; Lagares, J. I.; Sansaloni, F.; Arce, P.; Llop, J.

    2011-07-01

    In this communication, we present experimental results with a new neutron spectrometer, developed jointly by the Radiation Dosimetry Unit of CIEMAT Unita di Fisica and INFN-LNF Sanitary (Italy), consisting of a polyethylene moderating sphere detectors thermal neutrons (paired thermoluminescent dosimeters and activation foils) located in different positions. The device configuration and distribution of dosimeters are designed to elicit a response in a nearly isotropic up to 20 MeV energy range. (Author)

  10. Evaluation of neutron dosimetry techniques for well-logging operations

    International Nuclear Information System (INIS)

    Cummings, F.M.; Haggard, D.L.; Endres, G.W.R.

    1985-07-01

    Neutron dose and energy spectral measurements from 241 AmBe and a 14 MeV neutron generator were performed at a well-logging laboratory. The measurement technique included the tissue equivalent proportional counter, multisphere, two types of remmeters and five types of personnel neutron dosimeters. Several source configurations were used to attempt to relate data to field situations. The results of the measurements indicated that the thermoluminescent albedo dosimeter was the most appropriate personnel neutron dosimeter, and that the most appropriate calibration source would be the source normally employed in the field with the calibration source being used in the unmoderated configuration. 7 refs., 35 figs., 14 tabs

  11. Present status of fast neutron personnel dosimetry system based on CR-39 solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Pal, Rupali; Sathian, Deepa; Jayalakshmi, V.; Bakshi, A.K.; Chougaonkar, M.P.; Mayya, Y.S.; Kumar, Valli; Babu, Rajesh; Kar, S.; Joshi, V.M.

    2011-08-01

    Neutron sources are of different types depending upon the method of production such as nuclear reactors, particle accelerators and laboratory sources. Neutron sources depending upon their energy, flux, size etc. are used for variety of applications in basic and applied sciences, neutron scattering experiments and in industry such as oil well - digging, coal mining and processing, ore processing etc. Personnel working in nuclear installations such as reactors, accelerators, spent fuel processing plants, nuclear fuel cycle operations and those working in various industries such as oil refining, oil well-digging, coal mining and processing, ore processing, etc. need to be monitored for neutron exposures, if any. Neutron monitoring is especially necessary in view of the fact that the radiation weighting factor for neutron is much higher than gamma rays and also it varies with energy. Radiological Physics and Advisory Division is involved in monitoring of personnel working in neutron fields. Around 2100 workers from 70 institutions (DAE and Non-DAE) are monitored on a quarterly basis. Neutron personnel monitoring, carried out in the country is based on Solid State Nuclear Track Detection (SSNTD) technique. In this technique, neutrons interact with hydrogen in CR-39 polymer to produce recoil protons. These protons create damages in the polymer, which are enlarged and appear as tracks when subjected to electrochemical etching (ECE). These tracks are counted in an optical system to evaluate the neutron dose. The neutron dosimetry system based on SSNTD has undergone a significant development, since it was started in 1990. The development includes upgradation of image analysis system for counting tracks, introduction of chemical etching (CE) at elevated temperatures for evaluation of dose equivalents above 10 mSv and use of carbon laser for cutting of CR-39 detectors. The entire dose evaluation process has been standardized, which includes calibration and performance tests

  12. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    Standardized Physics-Dosimetry procedures and data are being developed and tested for monitoring the neutron doses accumulated by reactor pressure vessels (PV) and their support structures. These procedures and data are governed by a set of 21 ASTM standard practices, guides, and methods for the prediction of neutron-induced changes in light water reactor (LWR) PVs and support structure steels throughout the service life of the PV. This paper summarizes the applications of these standards to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and deployment of advanced dosimetry sets for commercial reactors is also summarized

  13. LWR-PV Surveillance Dosimetry Improvement Program review graphics

    International Nuclear Information System (INIS)

    McElroy, W.N.; Gold, R.; Gutherie, G.L.

    1979-10-01

    A primary objective of the multilaboratory program is to prepare an updated and improved set of dosimetry, damage correlation, and the associated reactor analysis ASTM standards for LWR-PV irradiation surveillance programs. Supporting this objective are a series of analytical and experimental validation and calibration studies in Benchmark Neutron Fields, reactor Test Regions, and operating power reactor Surveillance Positions. These studies will establish and certify the precision and accuracy of the measurement and predictive methods which are recommended for use in these standards. Consistent and accurate measurement and data analysis techniques and methods, therefore, will have been developed and validated along with guidelines for required neutron field calculations that are used to (1) correlate changes in material properties with the characteristics of the neutron radiation field and (2) predict pressure vessel steel toughness and embrittlement from power reactor surveillance data

  14. Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain

    International Nuclear Information System (INIS)

    Seppaelae, Tiina; Auterinen, Iiro; Aschan, Carita; Seren, Tom; Benczik, Judit; Snellman, Marjatta; Huiskamp, Rene; Ramadan, Usama Abo; Kankaanranta, Leena; Joensuu, Heikki; Savolainen, Sauli

    2002-01-01

    Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the brain of dogs before starting the clinical trials. A dose planning procedure was developed and uncertainties of the epithermal neutron-induced doses were estimated. The accuracy of the method of computing physical doses was assessed by comparing with in vivo dosimetry. Individual radiation dose plans were computed using magnetic resonance images of the heads of 15 Beagle dogs and the computational model of the FiR 1 epithermal neutron beam. For in vivo dosimetry, the thermal neutron fluences were measured using Mn activation foils and the gamma-ray doses with MCP-7s type thermoluminescent detectors placed both on the skin surface of the head and in the oral cavity. The degree of uncertainty of the reference doses at the thermal neutron maximum was estimated using a dose-planning program. The estimated uncertainty (±1 standard deviation) in the total physical reference dose was ±8.9%. The calculated and the measured dose values agreed within the uncertainties at the point of beam entry. The conclusion is that the dose delivery to the tissue can be verified in a practical and reliable fashion by placing an activation dosimeter and a TL detector at the beam entry point on the skin surface with homogeneous tissues below. However, the point doses cannot be calculated correctly in the inhomogeneous area near air cavities of the head model with this type of dose-planning program. This calls for attention in dose planning in human clinical trials in the corresponding areas

  15. The 235U Prompt Fission Neutron Spectrum in the BR1 Reactor at SCK•CEN

    Science.gov (United States)

    Wagemans, Jan; Malambu, Edouard; Borms, Luc; Fiorito, Luca

    2016-02-01

    The BR1 research reactor at SCK•CEN has a spherical cavity in the graphite above the reactor core. In this cavity an accurately characterised Maxwellian thermal neutron field is present. Different converters can be loaded in the cavity in order to obtain other types of neutron (and gamma) irradiation fields. Inside the so-called MARK III converter a fast 235U(n,f) prompt fission neutron field can be obtained. With the support of MCNP calculations, irradiations in MARK III can be directly related to the pure 235U(n,f) prompt fission neutron spectrum. For this purpose MARK III spectrum averaged cross sections for the most relevant fluence dosimetry reactions have been determined. A calibration factor for absolute measurements has been determined applying activation dosimetry following ISO/IEC 17025 standards.

  16. The 235U Prompt Fission Neutron Spectrum in the BR1 Reactor at SCK•CEN

    Directory of Open Access Journals (Sweden)

    Wagemans Jan

    2016-01-01

    Full Text Available The BR1 research reactor at SCK•CEN has a spherical cavity in the graphite above the reactor core. In this cavity an accurately characterised Maxwellian thermal neutron field is present. Different converters can be loaded in the cavity in order to obtain other types of neutron (and gamma irradiation fields. Inside the so-called MARK III converter a fast 235U(n,f prompt fission neutron field can be obtained. With the support of MCNP calculations, irradiations in MARK III can be directly related to the pure 235U(n,f prompt fission neutron spectrum. For this purpose MARK III spectrum averaged cross sections for the most relevant fluence dosimetry reactions have been determined. A calibration factor for absolute measurements has been determined applying activation dosimetry following ISO/IEC 17025 standards.

  17. Neutron optics using transverse field neutron spin echo method

    International Nuclear Information System (INIS)

    Achiwa, Norio; Hino, Masahiro; Yamauchi, Yoshihiro; Takakura, Hiroyuki; Tasaki, Seiji; Akiyoshi, Tsunekazu; Ebisawa, Toru.

    1993-01-01

    A neutron spin echo (NSE) spectrometer with perpendicular magnetic field to the neutron scattering plane, using an iron yoke type electro-magnet has been developed. A combination of cold neutron guider, supermirror neutron polarizer of double reflection type and supermirror neutron analyser was adopted for the spectrometer. The first application of the NSE spectrometer to neutron optics by passing Larmor precessing neutrons through gas, solid and liquid materials of several different lengths which are inserted in one of the precession field have been examined. Preliminary NSE spectra of this sample geometry are discussed. (author)

  18. Training of reverse propagation neural networks applied to neutron dosimetry; Entrenamiento de redes neuronales de propagacion inversa aplicadas a la dosimetria de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez P, C. F.; Martinez B, M. R.; Leon P, A. A.; Espinoza G, J. G.; Castaneda M, V. H.; Solis S, L. O.; Castaneda M, R.; Ortiz R, M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Av. Ramon Lopez Velarde 801, Col. Centro, 98000 Zacatecas, Zac. (Mexico); Mendez V, R. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Laboratorio de Patrones Neutronicos, Av. Complutense 22, 28040 Madrid (Spain); Gallego, E. [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, ETSI Industriales, Jose Gutierrez Abascal 2, 28006 Madrid (Spain); De Sousa L, M. A. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Neutron dosimetry is of great importance in radiation protection as aims to provide dosimetric quantities to assess the magnitude of detrimental health effects due to exposure of neutron radiation. To quantify detriment to health is necessary to evaluate the dose received by the occupationally exposed personnel using different detection systems called dosimeters, which have very dependent responses to the energy distribution of neutrons. The neutron detection is a much more complex problem than the detection of charged particles, since it does not carry an electric charge, does not cause direct ionization and has a greater penetration power giving the possibility of interacting with matter in a different way. Because of this, various neutron detection systems have been developed, among which the Bonner spheres spectrometric system stands out due to the advantages that possesses, such as a wide range of energy, high sensitivity and easy operation. However, once obtained the counting rates, the problem lies in the neutron spectrum deconvolution, necessary for the calculation of the doses, using different mathematical methods such as Monte Carlo, maximum entropy, iterative methods among others, which present various difficulties that have motivated the development of new technologies. Nowadays, methods based on artificial intelligence technologies are being used to perform neutron dosimetry, mainly using the theory of artificial neural networks. In these new methods the need for spectrum reconstruction can be eliminated for the calculation of the doses. In this work an artificial neural network or reverse propagation was trained for the calculation of 15 equivalent doses from the counting rates of the Bonner spheres spectrometric system using a set of 7 spheres, one of 2 spheres and two of a single sphere of different sizes, testing different error values until finding the most appropriate. The optimum network topology was obtained through the robust design

  19. Feasibility study of extremity dosemeter based on polyallyl-diglycol-carbonate (CR-39) for neutron exposure

    International Nuclear Information System (INIS)

    Chau, Q.; Bruguier, P.

    2007-01-01

    In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyl-diglycol-carbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces. (authors)

  20. Personal fast neutrons dosimetry using radiophotoluminescent glass

    International Nuclear Information System (INIS)

    Salem, Y. O.; Nachab, A.; Nourreddine, A.; Roy, C.

    2013-06-01

    In a previous paper we described a new ambient RPL dosimeter that detects fast neutrons in a mixed n-γ field via (n, p) reactions in a polyethylene converter. In the present study, a personal dosimeter is introduced to enable evaluating the individual dose equivalent H p (10) taking into account the albedo. A calibration factor for estimating H p (10) has been determined from the diminishing angular response as the angle of neutron incidence increases to 60 deg from the normal. MCNPX simulations for 241 Am-Be and 252 Cf neutrons, together with a series of monoenergetic neutron beams from 0.144 to 5 MeV, have been used to characterize the dosimeter response, which agrees well with the experimental 241 Am-Be response. (authors)

  1. Personnel neutron dosimetry using TLD elements at PNC

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu

    1985-01-01

    The evaluation method of neutron dose equivalent was studied on the basis of the albedo type neutron dosimetory to design the personnel dosimeter. The dosimeter was composed of three 6 Li 2 10 B 4 O 7 (Cu) TL elements and one 7 Li 2 11 B 4 O 7 (Cu) element. The equations for assessing thermal, epithermal and fast neutron dose equivalents were derived by 252 Cf, 241 Am-Be and PuO 2 neutron sources. The minimum detectable amount of 6 Li 2 10 B 4 O 7 (Cu) element to thermal neutron was 0.02 m rem. The neutron dose equivalent and the gamma one were evaluated separately within about 20 % error in the mixed radiation field. (author)

  2. Investigation of the thermoluminescent response of K2GdF5:Dy3+ crystals to photon radiation and neutron fields

    International Nuclear Information System (INIS)

    Silva, Edna C.; Faria, Luiz O.; Santos, Joelan A.L.; Vilela, Eudice C.

    2009-01-01

    The thermoluminescent (TL) properties of undoped and Dy 3+ doped K 2 GdF 5 crystals were investigated from the point of view of gamma and neutron dosimetry. Crystalline K 2 GdF 5 platelets with thickness of about 1 mm and doped with 0.0, 0.2, 1.0, 5.0 and 10.0 at.% Dy 3+ ions, synthesized under hydrothermal conditions, were irradiated in order to study TL sensitivity, as well as dose and energy response, reproducibility and fading. As it has been turned out, crystals doped with 5.0 at% Dy 3+ show the most efficient TL response and demonstrate a linear response to doses for all the radiation fields. TL glow curves from Dy 3+ doped K 2 GdF 5 crystals can be deconvoluted into four individual TL peaks centered at 153, 185, 216 and 234 deg C. Concerning the photon fields studied, the maximum TL response has been found for the 52.5 keV photons. The intensity is 15 times more than that of the response for the 662 keV photons from a Cs-137 source. On the other hand, the K 2 GdF 5 crystals doped with 5.0 at % Dy 3+ have also been found to have the better TL response for fast neutron radiation, among all dopants studied. For fast neutron radiation produced by a 241 Am-Be source, the TL responses for doses were also linear and comparable to that of commercial TLD-600, irradiated at same conditions. It has been established that the gamma sensitivity of the crystals is about 0.07% of the neutron sensitivity and the fast neutron sensitivity is about 4.5 % of the thermal neutron sensitivity. These results points out that K 2 Gd 0.95 Dy 0.05 F 5 crystals are good candidates for use in neutron dosimetry applications. (author)

  3. Radiation hygiene aspects of mixed neutron-gamma field dosimetry

    International Nuclear Information System (INIS)

    Nikodemova, O.; Hrabovcova, A.

    1982-01-01

    Various possibilities are analyzed of determining the dose equivalent of neutrons, as is the reliability of the techniques and the correct interpretation for the purposes of radiation hygiene. (author)

  4. Fast neutrons dosimetry

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1977-01-01

    A proton recoil technique has been developed for inducing thermoluminescence with incident fast neutrons. CaF 2 was used as the TL phosphor, and cane sugar and polyethylene were used as proton radiators. The phosphor and the hydrogeneous material powders were well mixed, encapsulated in glass tubes and exposed to Am-Be sources, resulting in recoils from incident fast neutrons of energy between 0,25 and 11,25 MeV. The intrinsic response of pure CaF 2 to fast neutrons without a hydrogeneous radiator was checked by using LiF (TLD-700). Glow curves were recorded from room temperature up to 350 0 C after different doses of neutrons and gamma rays of 60 Co. First collision dose due to fast neutrons in tissue like materials such as cane sugar and polyethylene was also calculated [pt

  5. Neutron dosimetry in the Three-Mile Island Unit 2 reactor cavity with solid-state track recorders

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Ruddy, F.H.; Preston, C.C.; McElroy, W.N.; Rao, S.V.; Greenborg, J.; Fricke, V.R.

    1986-01-01

    Solid-state track recorder (SSTR) neutron dosimetry has been conducted in the Three-Mile Island Unit 2 (TMI-2) reactor cavity, for nondestructive assessment of the fuel distribution. Two axial stringers were deployed in the annular gap with 17 SSTR dosimeters located on each stringer. SSTR experimental results reveal that neutron streaming, upward from the bottom of the reactor cavity region, dominates the observed neutron intensity. These absolute thermal neutron flux observations are consistent with the presence of a significant amount of fuel debris lying at the bottom of the reactor vessel. A conservative lower bound estimated from these SSTR data implies that at least 2 tonnes of fuel, which is roughly 4 fuel assemblies, is lying at the bottom of the vessel. This existence of significant neutron streaming also explains the high count rate observed with the source range monitors that are located in the TMI-2 reactor cavity. (author)

  6. Neutron spectrum adjustment using reaction rate data acquired with a liquid dosimetry system

    International Nuclear Information System (INIS)

    Smith, D.L.; Ikeda, Y.; Uno, Y.; Maekawa, F.

    1997-01-01

    A dosimetry technique based on neutron activation of circulating water with dissolved salts is discussed. The neutron source was the FNS accelerator at JAERI, Tokai, Japan. Yttrium chloride hexahydrate (YCl 3· 6H 2 O) was the salt (264.9 grams dissolved in 16.094 liters of water). Gamma-ray yields were measured with an intrinsic Ge detector. The following reactions were examined: (1) 16 O(n,p) 16 N (E thresh = 10.245 MeV, t 1/2 = 7.13 sec, E γ = 6.129 MeV); (2) 37 Cl(n,p) 37 S (E thresh = 4.194 MeV, t 1/2 = 5.05 min, E γ = 3.104 MeV); (3) 89 Y(n,n') 89m Y (E thresh = 0.919 MeV, t 1/2 = 16.06 sec, E γ = 0.909 MeV). This paper describes use of the generalized least-squares (GLS) method to adjust the neutron spectrum

  7. Design, construction and characterization of a dosimeter for neutron radiation

    International Nuclear Information System (INIS)

    Souto, Eduardo de Brito

    2007-01-01

    An individual dosimeter for neutron-gamma mixed field dosimetry was design and developed aiming monitoring the increasing number of workers potentially exposed to neutrons. The proposed dosimeter was characterized to an Americium-Beryllium source spectrum and dose range of radiation protection interest (up to 20 mSv). Thermoluminescent albedo dosimetry and nuclear tracks dosimetry, traditional techniques found in the international literature, with materials of low cost and national production, were used. A commercial polycarbonate, named SS-1, was characterized for solid state tack detector application. The chemical etching parameters and the methodology of detectors evaluation were determined. The response of TLD-600, TLD-700 and SS-1 were studied and algorithms for dose calculation of neutron and gamma radiation of Americium- Beryllium sources were proposed. The ratio between thermal, albedo and fast neutrons responses, allows analyzing the spectrum to which the dosimeter was submitted and correcting the track detector response to variations in the radiation incidence angle. The new dosimeter is fully characterized, having sufficient performance to be applied as neutron dosimeter in Brazil. (author)

  8. Neutron spectrometry and dosimetry in the environment and at workplaces

    International Nuclear Information System (INIS)

    Alevra, A.V.; Klein, H.; Knauf, K.; Wittstock, J.; Wolber, G.

    1998-01-01

    Results obtained in diverse environments (including workplaces) using both spectrometric and dosimetric instrumentation were compared. The following topics are included: PTB Bonner sphere spectrometers; natural cosmic ray-induced neutron background; neutron fields at the Dukovany nuclear power plant (Czech Republic); neutron fields at the isochronous cyclotron of the German Cancer Research center in Heidelberg; and accuracy of the integral results obtained with Bonner spheres. (P.A.)

  9. A new computation tool for neutron spectrometry and dosimetry; Una nueva herramiento de computo para la espectrometria y dosimetria de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Martinez B, M. R.; Ortiz R, J. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Av. Ramon Lopez Velarde No. 801, Col. Centro, Zacatecas (Mexico)], e-mail: mrosariomb@yahoo.com.mx

    2009-10-15

    By using the integrated accounts of spectrometric system of Bonner spheres is possible to reconstruct the neutron spectrum using various methods such as: Monte Carlo, the parameterization and iterative methods. The response matrix, counting rates and neutron spectrum are intimately related through the integral-differential of Fredholm of first type. however, the weight of Bonner spheres system, the procedure of spectra reconstruction, the need of a expert user, the high time consumption, the need to use a reconstruction code (BUNKI, SAND, among others) and the spectrum resolution, are some of problems that this system presents. The above difficulties have motivated the development of complementary procedures such as maximum entropy, genetic algorithms and artificial neural networks. In recent years, using neural network technology has become an alternative procedure in the nuclear science research area, considering a replacement for classical techniques used for years. In previous works, was used a new method called robust design methodology of artificial neural networks, to construct various network topologies capable of solving the problems of neutron spectrometry and dosimetry, however noted that not exist tools for end-user that allow test and validate the designed networks. This paper presents the development of a software for neutronic spectrometry and dosimetry, based on information extracted from an artificial neural network designed in previous work, through the robust design methodology of artificial neural networks with the following characteristics: was designed in a user graphical interface easy to use, speed on the application execution, unlike other deconvolution codes, not is necessary to select and initial spectrum for spectrum reconstruction, as an additional element to this tool, besides spectrum, the calculation is performed simultaneous of 13 equivalent dose from just counting rates from a spectrometric system of Bonner spheres. (Author)

  10. Twenty-first nuclear accident dosimetry intercomparison study, August 6-10, 1984

    International Nuclear Information System (INIS)

    Swaja, R.E.; Ragan, G.E.; Sims, C.S.

    1985-05-01

    The twenty-first in a series of nuclear accident dosimetry (NAD) intercomparison (NAD) studies was conducted at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during August 6-10, 1984. The Health Physics Research Reactor operated in the pulse mode was used to simulate three criticality accidents with different radiation fields. Participants from five organizations measured neutron doses between 0.53 and 4.36 Gy and gamma doses between 0.19 and 1.01 Gy at area monitoring stations and on phantoms. About 75% of all neutron dose estimates based on foil activation, hair activation, simulated blood sodium activation, and thermoluminescent methods were within +-25% of reference values. Approximately 86% of all gamma results measured using thermoluminescent (TLD-700 or CaSO 4 ) systems were within +-20% of reference doses which represents a significant improvement over previous studies. Improvements observed in the ability of intercomparison participants to estimate neutron and gamma doses under criticality accident conditions can be partly attributed to experience in previous NAD studies which have provided practical tests of dosimetry systems, enabled participants to improve evaluation methods, and standardized dose reporting conventions. 16 refs., 15 tabs

  11. Use of CR-39 foils for personnel neutron dosimetry: improved electrochemical etching chambers and procedures

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1986-01-01

    The electrochemical etching procedures for the new dosimetry system that uses foils of CR-39 plastic has been improved. During 1985, the etching chambers were modified to correct several problems and the changes to the etching procedures were studied, which gave a more uniform track density and size. The currently recommended etch parameters are given. A new generation of CR-39 material from the manufacturer proved to have a considerably lower background track density and a higher sensitivity; the new foils are also more uniform in thickness, which eliminates the need to numerically compensate for thickness variations. The energy dependence of the CR-39 using monoenergetic neutrons from accelerators at Battelle Northwest Laboratories and at Los Alamos National Laboratory was determined. Some variation was found in the energy dependence, but it is believed this was caused by changes in the etching procedures and by uncertainties in the fluences of the neutrons from the accelerators. A means by which the counting of CR-39 tracks may be automated is suggested; this would be very useful in adapting the CR-39 dosimetry system to large-scale use

  12. Collaborative Physical and Biological Dosimetry Studies for Neutron Capture Therapy at the RA-1 Research Reactor Facility

    Energy Technology Data Exchange (ETDEWEB)

    David W. Nigg; Amanda E. Schwint; John K. Hartwell; Elisa M. Heber; Veronica Trivillin; Jorge Castillo; Luis Wentzeis; Patrick Sloan; Charles A. Wemple

    2004-10-01

    Initial physical dosimetry measurements have been completed using activation spectrometry and thermoluminiscent dosimeters to characterize the BNCT irradiation facility developed at the RA-1 research reactor operated by the Argentine National Atomic Energy Commission in Buenos Aires. Some biological scoping irradiations have also been completed using a small-animal (hamster) oral mucosa tumor model. Results indicate that the RA-1 neutron source produces useful dose rates but that some improvements in the initial configuration will be needed to optimize the spectrum for thermal-neutron BNCT research applications.

  13. Collaborative Physical and Biological Dosimetry Studies for Neutron Capture Therapy at the RA-1 Research Reactor Facility

    Energy Technology Data Exchange (ETDEWEB)

    Nigg, D.W.; Schwint, A.E.; Hartwell, J.K.; Heber, E.M.; Trivillin, V.; Castillo, J.; Wentzeis, L.; Sloan, P.; Wemple, C.A.

    2004-10-04

    Initial physical dosimetry measurements have been completed using activation spectrometry and thermoluminiscent dosimeters to characterize the BNCT irradiation facility developed at the RA-1 research reactor operated by the Argentine National Atomic Energy Commission in Buenos Aires. Some biological scoping irradiations have also been completed using a small-animal (hamster) oral mucosa tumor model. Results indicate that the RA-1 neutron source produces useful dose rates but that some improvements in the initial configuration will be needed to optimize the spectrum for thermal-neutron BNCT research applications.

  14. Development of a hand-held fast neutron survey meter

    International Nuclear Information System (INIS)

    Yoshida, T.; Tsujimura, N.; Yamano, T.

    2011-01-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ∼2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters. (authors)

  15. Neutron dosimetry in the Three-Mile Island Unit 2 reactor cavity with solid-state track recorders

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Ruddy, F.H.; Preston, C.C.; McElroy, W.N.; Rao, S.V.; Greenborg, J.; Fricke, V.R.

    1985-01-01

    Solid-state track recorder (SSTR) neutron dosimetry has been conducted in the Three-Mile Island Unit 2 (TMI-2) reactor cavity (i.e., the annular gap between the pressure vessel and the biological shield) for nondestructive assessment of the fuel distribution. Two axial stringers were deployed in the annular gap with 17 SSTR dosimeters located on each stringer. SSTR experimental results reveal that neutron streaming, upward from the bottom of the reactor cavity region, dominates the observed neutron intensity. These absolute thermal neutron flux observations are consistent with the presence of a significant amount of fuel debris lying at the bottom of the reactor vessel. A conservative lower bound estimated from these SSTR data implies that at least 2 tonnes of fuel, which is roughly 4 fuel assemblies, is lying at the bottom of the vessel. The existence of significant neutron streaming also explains the high count rate observed with the source range monitors (SRMs) that are located in the TMI-2 reactor cavity

  16. A broad-group cross-section library based on ENDF/B-VII.0 for fast neutron dosimetry Applications

    Energy Technology Data Exchange (ETDEWEB)

    Alpan, F.A. [Westinghouse Electric Company, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2011-07-01

    A new ENDF/B-VII.0-based coupled 44-neutron, 20-gamma-ray-group cross-section library was developed to investigate the latest evaluated nuclear data file (ENDF) ,in comparison to ENDF/B-VI.3 used in BUGLE-96, as well as to generate an objective-specific library. The objectives selected for this work consisted of dosimetry calculations for in-vessel and ex-vessel reactor locations, iron atom displacement calculations for reactor internals and pressure vessel, and {sup 58}Ni(n,{gamma}) calculation that is important for gas generation in the baffle plate. The new library was generated based on the contribution and point-wise cross-section-driven (CPXSD) methodology and was applied to one of the most widely used benchmarks, the Oak Ridge National Laboratory Pool Critical Assembly benchmark problem. In addition to the new library, BUGLE-96 and an ENDF/B-VII.0-based coupled 47-neutron, 20-gamma-ray-group cross-section library was generated and used with both SNLRML and IRDF dosimetry cross sections to compute reaction rates. All reaction rates computed by the multigroup libraries are within {+-} 20 % of measurement data and meet the U. S. Nuclear Regulatory Commission acceptance criterion for reactor vessel neutron exposure evaluations specified in Regulatory Guide 1.190. (authors)

  17. Need of Reactor Dosimetry Preservation

    International Nuclear Information System (INIS)

    Ilieva, Krassimira

    2011-01-01

    The nuclear safety requirements and philosophy have changed by the development of new nuclear systems and this imposes special research and development activity. Reactor dosimetry which is applied for determination of neutron field parameters and neutron flux responses in different regions of the reactor system plays an important role in determining of radiation exposure on reactor system elements as reactor vessel, internals, shielding; dose determination for material damage study; for conditioning of irradiation; dose determination for medicine and industry application; induced activity determination for decommissioning purposes. The management of nuclear knowledge has emerged as a growing challenge in recent years. The need to preserve and transfer nuclear knowledge is compounded by recent trends such as ageing of the nuclear workforce, declining student numbers in nuclear related fields, and the threat of losing accumulated nuclear knowledge. (author)

  18. Neutron field for activation experiments in horizontal channel of training reactor VR-1

    Czech Academy of Sciences Publication Activity Database

    Štefánik, Milan; Katovsky, K.; Vinš, M.; Šoltéš, J.; Závorka, L.

    2014-01-01

    Roč. 104, NOV (2014), s. 302-305 ISSN 0969-806X. [1st International Conference on Dosimetry and its Applications (ICDA). Prague, 23.6.2013-28.6.2013] R&D Projects: GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : spectral index * neutron spectrometry * dosimetry-foils activation technique * irradiation channel * reaction rate * Gamma -spectroscopy Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.380, year: 2014

  19. Energy response study of modified CR-39 neutron personnel dosimeter

    International Nuclear Information System (INIS)

    Sathian, Deepa; Bakshi, A.K.; Datta, D.; Nair, Sreejith S.; Sathian, V.; Mishra, Jitendra; Sen, Meghnath

    2018-01-01

    Personnel neutron dosimetry is an integral part of radiation protection. No single dosimeter provides the satisfactory energy response, sensitivity, angular dependence characteristics and accuracy necessary to meet the requirement of an ideal personnel neutron dosimeter. The response of a personnel neutron dosimeter is critically dependent upon the energy distribution of the neutron field. CR-39 personnel neutron dosimeters were typically calibrated in the standard neutron field of 252 Cf and 241 Am-Be in our laboratory, although actual neutron fields may vary from the calibration neutron spectrum. Recently the badge cassette of the personnel neutron dosimeter was changed due to frequent damage of the PVC badge used earlier. This paper discusses energy response of CR-39 solid state nuclear track detector loaded in this modified badge cassette as per latest ISO recommendation

  20. Guide for selection and calibration of dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    2002-01-01

    This guide covers the basis for selecting and calibrating dosimetry systems used to measure absorbed dose in gamma ray or X-ray fields and in electron beams used for radiation processing. It discusses the types of dosimetry systems that may be employed during calibration or on a routine basis as part of quality assurance in commercial radiation processing of products. This guide also discusses interpretation of absorbed dose and briefly outlines measurements of the uncertainties associated with the dosimetry. The details of the calibration of the analytical instrumentation are addressed in individual dosimetry system standard practices. The absorbed-dose range covered is up to 1 MGy (100 Mrad). Source energies covered are from 0.1 to 50 MeV photons and electrons. This guide should be used along with standard practices and guides for specific dosimetry systems and applications covered in other standards. Dosimetry for radiation processing with neutrons or heavy charged particles is not covered in this guide

  1. Dosimetry issues for an ultra-high flux beam and multipurpose research reactor design

    International Nuclear Information System (INIS)

    West, C.D.

    1993-01-01

    The Advanced Neutron Source is a new user facility for all fields of neutron research, including neutron beam experiments, materials analysis, materials testing, and isotope production. The complement and layout of the experimental facilities have been determined sufficiently, at a conceptual design level, to make reliable cost and schedule estimates. The source of neutrons will be a heavy water reactor, constructed largely of aluminum, with an available thermal neutron flux 5--10 times higher than existing research reactors. Among the dosimetry issues to be faced are damage prediction and surveillance for component life attainment; measurement of fluence and spectra in regions where both change substantially over a distance of a few centimeters; and characterization and measurement of the radiation field in the research areas around the neutron beam experiments

  2. MO-D-BRD-02: In Memoriam of Bengt Bjarngard: SBRT II: Small Field Dosimetry - TG155

    International Nuclear Information System (INIS)

    Das, I; Reft, C

    2014-01-01

    Specialized radiation treatment such as SRS/SRT. SBRT, IMRT, VMAT, Tomotherapy, CyberKnife and Gamma Knife use small fields or combination of small fields where dosimetry is challenging and uncertain due to non-equilibrium conditions such as longitudinal and lateral disequilibrium. Additionally the primary photon fluence is greatly affected by the obstruction of the source size by the jaws creating a large dose gradient across the field. Electronic equilibrium is a phenomenon associated with the range of secondary particles which depend on the beam energy, photon spectrum and the composition of the medium. Additionally, the finite size of detectors creates volume averaging and fluence perturbations especially in small fields. The IAEA/AAPM has provided a frame work for non-compliant reference dosimetry in small fields1. The AAPM TG-1552 has adopted this frame work to provide guidelines in relative dosimetry. This course provides the insight of TG-155 that defines small field, provides recommendations for suitable detectors and associated correction factors to convert reading to dose. Recommendations of a good working practice for relative dosimetry measurements (PDD, TMR, output factor, etc.) and dose calculations based on the new formulation is are elaborated. It also discusses beam modeling and dose calculations as a critical step in clinical utilization of small field radiotherapy. Small errors in beam data, approximations in dose algorithms, or misaligned of detectors and field settings can propagate into large errors in planned and delivered dose. The modeling and treatment planning aspects of small field dosimetry are reviewed with emphasis on the most critical parts for ensuring accurate and safe radiation therapy. Discussion on k(fmsr, fclin) for commercially available detectors are also provided.1 P. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjall, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich and S. Vatnitsky, “A new

  3. Intercomparison of radiation protection devices in a high-energy stray neutron field. Part III: Instrument response

    International Nuclear Information System (INIS)

    Silari, M.; Agosteo, S.; Beck, P.; Bedogni, R.; Cale, E.; Caresana, M.; Domingo, C.; Donadille, L.; Dubourg, N.; Esposito, A.; Fehrenbacher, G.; Fernandez, F.; Ferrarini, M.; Fiechtner, A.; Fuchs, A.; Garcia, M.J.; Golnik, N.; Gutermuth, F.; Khurana, S.; Klages, Th.

    2009-01-01

    The European Commission has funded within its 6th Framework Programme a three-year project (2005-2007) called CONRAD, COordinated Network for RAdiation Dosimetry. The organizational framework for this project was provided by the European radiation Dosimetry Group EURADOS. Work Package 6 of CONRAD dealt with 'complex mixed radiation fields at workplaces' and in this context it organised a benchmark exercise, which included both measurements and calculations, in a stray radiation field at a high-energy particle accelerator at GSI, Germany. The aim was to intercompare the response of several types of active detectors and passive dosemeters in a well-characterised workplace field. The Monte Carlo simulations of the radiation field and the experimental determination of the neutron spectra with various Bonner Sphere Spectrometers are discussed in Rollet et al. (2008) and in Wiegel et al. (2008). This paper focuses on the intercomparison of the response of the dosemeters in terms of ambient dose equivalent. The paper describes in detail the detectors employed in the experiment, followed by a discussion of the results. A comparison is also made with the H*(10) values predicted by the Monte Carlo simulations and those measured by the BSS systems.

  4. Out‐of‐field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators

    Science.gov (United States)

    Cardenas, Carlos E.; Nitsch, Paige L.; Kudchadker, Rajat J.; Howell, Rebecca M.

    2016-01-01

    Out‐of‐field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high‐energy electron beams. To better understand the extent of these exposures, we measured out‐of‐field dose characteristics of electron applicators for high‐energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out‐of‐field dose profiles and percent depth‐dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out‐of‐field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out‐of‐field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central‐axis, which was found to be higher than typical out‐of‐field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for

  5. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

    Science.gov (United States)

    Cardenas, Carlos E; Nitsch, Paige L; Kudchadker, Rajat J; Howell, Rebecca M; Kry, Stephen F

    2016-07-08

    Out-of-field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high-energy electron beams. To better understand the extent of these exposures, we measured out-of-field dose characteristics of electron applicators for high-energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out-of-field dose profiles and percent depth-dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out-of-field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out-of-field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central-axis, which was found to be higher than typical out-of-field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for special cases.

  6. Reassessment of the RERF dosimetry system - overview of the new dosimetry system DS02

    International Nuclear Information System (INIS)

    Young, R.W.

    2003-01-01

    This paper describes a major reassessment of the system used at the Radiation Effects Research Foundation (RERF) to determine radiation doses for atomic-bomb survivors. This effort has resolved the neutron discrepancy in RERF dosimetry, and has defined the parameters for a replacement system for survivor dose calculation. A Joint US-Japan Working Group undertook a comprehensive evaluation of the calculations that comprise the RERF dosimetry system and the measurements used to verify those calculations. During the course of this reassessment, the working groups, with members from American, German and Japanese universities and national laboratories, have recomputed all of the Hiroshima and Nagasaki radiation calculations, made fast-neutron and low-background thermal-neutron measurements, upgraded the calculation of the radiation shielding provided by terrain and large buildings, and conducted a comprehensive reassessment of all radiation measurements. The new calculations produced during this reassessment agree with both gamma and neutron measurements out to distances from the detonations at which in-situ measurements become indistinguishable from background, effectively resolving the long-standing neutron dose discrepancy. The calculations that produce this agreement are the basis for the new DS02 dosimetry system. New calculations and measurements confirmed the yield and epicenter for the Nagasaki detonation while refining both these values for Hiroshima. Current measurements and calculations confirm a 21-kiloton-yield for the Nagasaki bomb and a burst point to within two meters of previous assessments. In Hiroshima, the estimated yield has been increased from 15 kt to 16 kt and the epicenter has been repositioned 20 meters higher and 15 meters to the west. While these refined parameters make the dosimetry system more accurate and users of the system more confident in the results, the calculated dose to survivors will change only about ten percent

  7. DOE personnel neutron dosimetry evaluation and upgrade program

    International Nuclear Information System (INIS)

    Faust, L.G.; Stroud, C.M.; Vallario, E.J.

    1988-01-01

    The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the absorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is being developed to provide guidance in implementing the January 1987 Presidential Directive to determine effective dose equivalent. Superheated Drop Detectors are being investigated for their potential as real time neutron dosimeters. This paper includes discussions of these improvements brought about by the DOE research program

  8. Neutron converter at reactor RB; Konvertor neutrona na reaktoru RB

    Energy Technology Data Exchange (ETDEWEB)

    Strugar, P; Sotic, P; Ninkovic, M; Pesic, M [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)

    1977-07-01

    A neutron converter at Reactor RB in the 'Boris Kidric' Institute of Nuclear Sciences - Vinca has been constructed. Preliminary measurements have been shown that the converted neutron spectrum is very similar to the fission neutron spectrum. For the same integral reactor power, the measured neutron radiation dose has been for about ten times larger with the neutron converter. The neutron converter offers wide possibilities, as in investigations in the reactor physics, where the fission neutron spectra have been required, as well as in the field of neutron dosimetry and biological irradiations (author)

  9. The JENDL-3 Sublibrary for Dosimetry. Summary of contents

    International Nuclear Information System (INIS)

    Nakazawa, M.; Kobayashi, K.; Iwasaki, S.; Iguchi, T.; Sakurai, K.; Ikeda, Y.; Nakagawa, T.

    1992-01-01

    This document summarizes the contents of the JENDL-3 Sublibrary for Dosimetry. This nuclear data library contains neutron activation cross-sections for selected materials that are used for reactor neutron dosimetry by foil activation. The library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section upon request. (author)

  10. Comparative measurements on different thermoluminescence materials for the dosimetry in mixed radiation fields; Vergleichende Messungen an unterschiedlichen Thermolumineszenzmaterialien fuer die Dosimetrie in gemischten Strahlenfeldern

    Energy Technology Data Exchange (ETDEWEB)

    Pillath, J.; Uray, I.

    2006-05-15

    LiF-based thermoluminescence materials (TL materials) have proved efficient and become established for dosimetry for many years now. In combination with suitable filtrations or moderators, they permit high-precision measurements of the radiation doses of all types of radiation relevant in radiation protection. The development of highly sensitive LiF materials with a doping of Mg, P and Cu has made it possible to measure doses down to one {mu}Sv. The measurements presented here specifically serve to phenomenologically analyse the glow curve structure of normally and highly sensitive LiF-TL materials in mixed gamma-neutron radiation fields. The sensitivity of the different TL materials to different types of radiation and the influence of the radiation types and of the evaluation parameters on the structure of the glow curves is examined. It is made apparent how information about the composition and doses of the individual components of a radiation field can be obtained by decomposing the glow curve into its individual peaks. (orig.)

  11. Determination of natural radioactive elements in building materials by gamma spectroscopy, trace dosimetry and neutron activation analysis

    International Nuclear Information System (INIS)

    Perez, G.; Desdin, L.F.; Hernandez, A.T.; Gonzalez, D.; Labrada, A.; Tenreiro, J.J.; Capote, G.; Perelyguin, V.P.; Herrera, H.; Tellez, E.

    1993-01-01

    Five types of Cuban concretes and their main components (minerals aggregates and cement) were investigated in order to analyze the content of uranium, thorium, radium, potassium and radon 220,222, using gamma spectroscopy, trace dosimetry and neutron activation analysis. The comparative evaluation of different concretes, aggregates and two types of cements according to natural radioactivity is shown

  12. Study of neutron fields around an intense neutron generator.

    Science.gov (United States)

    Kicka, L; Machrafi, R; Miller, A

    2017-12-01

    Neutron fields in the vicinity of the newly built neutron facility, at the University of Ontario Institute of Technology (UOIT), have been investigated in a series of Monte Carlo simulations and measurements. The facility hosts a P-385 neutron generator based on a deuterium-deuterium fusion reaction. The neutron fluence at different locations around the neutron generator facility has been simulated using MCNPX 2.7E Monte Carlo particle transport program. To characterize neutron fields, three neutron sources were modeled with distributions corresponding to different incident deuteron energies of 90kV, 110kV, and 130kV. Measurements have been carried out to determine the dose rate at locations adjacent to the generator using bubble detectors (BDs). The neutron intensity was evaluated and the total dose rates corresponding to different applied acceleration potentials were estimated at various locations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Field arrangement and dosimetry verification for concave target

    International Nuclear Information System (INIS)

    Chen Liang; Wang Huankun; Li Yumin

    2005-01-01

    Objective: To provide a method of radiotherapy field arrangement for concave paraspinal target. Methods: Plan was designed for concave target in wax phantom and the selected patients by the guidance of beam eye view (BEV) provided by a 3D treatment planning system (CREAT EXPERT). In BEV, the inner border of all tangential fields was 2 mm out of the organ at risk (OAR) and the outer border was 5 mm beyond the target. Dosimetry films and ion chamber were used to verify the dose distribution and point dose in the wax phantom. Results: Dose distribution in phantom and patient was homogeneous. The mean dose of OAR in phantom did not exceed 16% of the prescribed dose. Isodose curves dropped more than 8% per mm between the target and OAR in the phantom. Film dosimetry coincided well with the calculated results. Position error in high dose region was with- in 4 mm and absolute dose errors were no more than 5%. Conclusion: Tangential field arrangement is valuable and practical in radiotherapy for concave paraspinal targets. (authors)

  14. Dosimetry

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The purpose of ionizing radiation dosimetry is the measurement of the physical and biological consequences of exposure to radiation. As these consequences are proportional to the local absorption of energy, the dosimetry of ionizing radiation is based on the measurement of this quantity. Owing to the size of the effects of ionizing radiation on materials in all of these area, dosimetry plays an essential role in the prevention and the control of radiation exposure. Its use is of great importance in two areas in particular where the employment of ionizing radiation relates to human health: radiation protection, and medical applications. Dosimetry is different for various reasons: owing to the diversity of the physical characteristics produced by different kinds of radiation according to their nature (X- and γ-photons, electrons, neutrons,...), their energy (from several keV to several MeV), the orders of magnitude of the doses being estimated (a factor of about 10 5 between diagnostic and therapeutic applications); and the temporal and spatial variation of the biological parameters entering into the calculations. On the practical level, dosimetry poses two distinct yet closely related problems: the determination of the absorbed dose received by a subject exposed to radiation from a source external to his body (external dosimetry); and the determination of the absorbed dose received by a subject owing to the presence within his body of some radioactive substance (internal dosimetry)

  15. Reactor dosimetry knowledge preservation and development

    International Nuclear Information System (INIS)

    Ilieva, K.D.; Belousov, S.I.; Mitev, M.R.

    2010-01-01

    The nuclear safety requirements and philosophy have changed by the development of new nuclear systems and this imposes special research and development activity. Reactor dosimetry which is applied for determination of neutron field parameters and neutron flux responses in different regions of the reactor system plays an important role in determining of radiation exposure on reactor system elements as reactor vessel, internals, shielding; dose determination for material damage study; in dose determination and conditioning of irradiation for medicine and industry application as well as in induced activity determination for decommissioning purposes. The management of nuclear knowledge has emerged as a growing challenge in recent years. The need to preserve and transfer nuclear knowledge is compounded by recent trends such as ageing of the nuclear workforce, declining student numbers in nuclear related fields, and the threat of losing accumulated nuclear knowledge. (authors)

  16. Neutron dosimetry at nuclear power plants with light water reactors (LWR)

    International Nuclear Information System (INIS)

    Hofmann, B.; Schwarz, W.; Burgkhardt, B.; Piesch, E.

    1989-02-01

    During nuclear start-up of the Muelheim-Kaerlich nuclear power plant in 1986 the neutron radiation fields in the primary and auxiliary component rooms of the containment were investigated using the Single Sphere Albedo Technique and additional measurement techniques. For personnel monitoring albedo neutron dosemeters were used consisting of thermoluminescent detectors and track etch detectors combined with boron converters. Results: (1) The neutron radiation fields reach dose rate values up to 1000 mSv/h at the sleeves of the reactor coolant pipes, in the refuelling pool and the reactor cavity sump. The neutron component varies between 10% in the steam generator rooms up to 92% in the refuelling pool. (2) The mean value of the effective neutron energy at the different locations was found to be about 100 keV. Thermal neutrons contribute with about 10% to the area dose. (3) By direct intercomparisons and different evaluation methods of the Single Sphere Albedo Dosemeter it was shown, that rem-counters used within routine monitoring in the mixed radiation fields of the LWR overestimate the neutron dose rate only insignificantly (+20%) and are therefore usable for practical radiation protection work. (4) The sensitivity of albedo neutron dosemeters allows the detection of neutrons above 10 μSv. The contribution of neutrons to the total personnel dose was 25% in maximum. For the evaluation of albedo detectors a constant calibration factor can be applied. (orig./HP) [de

  17. Neutron dosimetry and spectrometry with Bonner spheres. Working out a log-normal reference matrix

    International Nuclear Information System (INIS)

    Zaborowski, Henrick.

    1981-11-01

    From the experimental and theoretical studies made upon the BONNER's spheres System with a I 6 Li(Eu) crystal and with a miniaturized 3 He counter we get the normalized energy response functions R*sub(i)(E). This normalization is obtained by the mathematization of the Resolution Function R*(i,E) in the Log-Normal distribution hypothesis to mono energetic neutrons given in April 1976 to the International Symposium on Californium 252. The fit of the Log-Normal Hypothesis with the experimental and Theoretical data is very satisfactory. The parameter's tabulated values allow a precise interpolation, at all energies between 0.4 eV and 15 MeV and for all spheres diameters between 2 and 12 inches, of the discretized R*sub(ij) Reference Matrix for the applications to neutron dosimetry and spectrometry [fr

  18. The LLNL CR-39 personnel neutron dosimeter

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.; Westermark, J.

    1987-01-01

    We developed a personnel neutron dosimetry system based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This CR-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. 3 refs., 4 figs

  19. Integrating techniques for neutron dosimetry in Linac 18 MV; Integrando tecnicas para dosimetria de neutrones en un Linac de 18 MV

    Energy Technology Data Exchange (ETDEWEB)

    Ceron R, P. V.; Diaz G, J. A. I.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico); Paredes G, L. C. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-10-15

    In this paper thermoluminescent dosimetry, analytical techniques and Monte Carlo calculations were used to estimate the neutron dose equivalent in a radiotherapy room with a linear electron accelerator of 18 MV. The equivalent dose was measured at isocenter to 1.42 m of target and at the entrance of the labyrinth of the room of a Novalis Tx. The neutron detectors were constructed with pairs of thermoluminescent dosimeters TLD 600 ({sup 6}LiF: Mg, Ti) and TLD 700 ({sup 7}LiF: Mg, Ti) which are placed inside a paraffin sphere of 20 cm in diameter. These measurements enabled the calculation of equivalent dose in the gate and the source term, using the relationships contained in the NCRP-151. Through the models carried out with the code MCNPX the absorbed dose distribution with regard to depth in a paraffin phantom are included and the neutron spectrum produced by the head, taking into account the geometry and component materials. The results are in the order of neutron milli sievert by gray of X-rays (mSv/Gy x) which are in the same order as those found in other reports for different accelerators. (Author)

  20. Eurados trial performance test for photon dosimetry

    DEFF Research Database (Denmark)

    Stadtmann, H.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    Within the framework of the EURADOS Action entitled Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation, trial performance tests for whole-body and extremity personal dosemeters were carried out. Photon, beta and neutron dosemeters were considered....... This paper summarises the results of the whole-body photon dosemeter test. Twenty-six dosimetry services from all EU Member States and Switzerland participated. Twelve different radiation fields were used to simulate various workplace irradiation fields. Dose values from 0.4 mSv to 80 mSv were chosen. From...

  1. Results from the CDE phase activity on neutron dosimetry for the international fusion materials irradiation facility test cell

    CERN Document Server

    Esposito, B; Maruccia, G; Petrizzi, L; Bignon, G; Blandin, C; Chauffriat, S; Lebrun, A; Recroix, H; Trapp, J P; Kaschuck, Y

    2000-01-01

    The international fusion materials irradiation facility (IFMIF) project deals with the study of an accelerator-based, deuterium-lithium source, producing high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials for fusion energy reactors. IFMIF would also provide calibration and validation of data from fission reactor and other accelerator based irradiation tests. This paper describes the activity on neutron/gamma dosimetry (necessary for the characterization of the specimens' irradiation) performed in the frame of the IFMIF conceptual design evaluation (CDE) neutronics tasks. During the previous phase (conceptual design activity (CDA)) the multifoil activation method was proposed for the measurement of the neutron fluence and spectrum and a set of suitable foils was defined. The cross section variances and covariances of this set of foils have now been used for tests on the sensitivity of the IFMIF neutron spectrum determination to cross section uncertainties...

  2. Beam shaping assembly of a D–T neutron source for BNCT and its dosimetry simulation in deeply-seated tumor

    International Nuclear Information System (INIS)

    Faghihi, F.; Khalili, S.

    2013-01-01

    This article involves two aims for BNCT. First case includes a beam shaping assembly estimation for a D–T neutron source to find epi-thermal neutrons which are the goal in the BNCT. Second issue is the percent depth dose calculation in the adult Snyder head phantom. Monte-Carlo simulations and verification of a suggested beam shaping assembly (including internal neutron multiplier, moderator, filter, external neutron multiplier, collimator, and reflector dimensions) for thermalizing a D–T neutron source as well as increasing neutron flux are carried out and our results are given herein. Finally, we have simulated its corresponding doses for treatment planning of a deeply-seated tumor. - Highlights: ► An assembly for the D–T neutron source including many regions is given herein. ► Dosimetry simulations in the Snyder head phantom for a deeply-seated tumor are carried out. ► Brief literatures conclusions on the recent BNCT studies are presented herein

  3. The application of calorimetrical methods in nuclear technology and dosimetry

    International Nuclear Information System (INIS)

    Kott, J.; Krett, V.; Novotny, J.; Kovar, Z.; Jirousek, V.

    1985-01-01

    The report reviews theoretical as well as experimental research activities devoted to the possibilities of measuring reactor neutron and photon fields using thermic detectors based on calorimetric principle. There have been worked out theoretical principles of a reactor measuring probe intended in the first place to measuring neutron fluxes under operational temperatures inside power and research reactors, and a new philosophy of measurement has been elaborated. In addition, the report presents the experimental results as obtained on research reactors WWR-S, WWR-SM, RA, and Czechoslovak power reactor A-1 and GDR power reactor WWR-2. These results are given in connection with a newly proposed technique of reactor neutron field detection. The second part of the report presents results of works concerning beam dosimetry with the use of calorimeters

  4. Irradiation test of HAFM and tag gas samples at the standard neutron field of 'YAYOI'

    International Nuclear Information System (INIS)

    Iguchi, Tetsuo

    1997-03-01

    To check the accuracy of helium accumulation neutron fluence monitors (HAFM) as new technique for fast reactor neutron dosimetry and the applicability of tag gas activation analysis to fast reactor failed fuel detection, their samples were irradiated at the standard neutron field of the fast neutron source reactor 'YAYOI' (Nuclear Engineering Research Laboratory, University of Tokyo). Since October in 1996, the HAFM samples such as 93% enriched boron (B) powders of 1 mg and natural B powders of 10 mg contained in vanadium (V) capsule were intermittently irradiated at the reactor core center (Glory hole: Gy) and/or under the leakage neutron field from the reactor core (Fast column: FC). In addition, new V capsules filled with enriched B of 40 mg and Be of 100 mg, respectively, were put into an experimental hole through the blanket surrounding the core. These neutron fields were monitored by the activation foils consisting of Fe, Co, Ni, Au, 235 U, 237 Np etc., mainly to confirm the results obtained from 1995's preliminary works. In particular, neutron flux distributions in the vicinity of irradiated samples were measured in more detail. At the end of March in 1997, the irradiated neutron fluence have reached the goal necessary to produce the detectable number of He atoms more than ∼10 13 in each HAFM sample. Six kinds of tag gas samples, which are the mixed gases of isotopically adjusted Xe and Kr contained in SUS capsules, were separately irradiated three times at Gy under the neutron fluence of ∼10 16 n/cm 2 in average. After irradiation, γ-ray spectra were measured for each sample. Depending on the composition of tag gas mixtures, the different patterns of γ-ray peak spectra from 79 Kr, 125 Xe, etc. produced through tag gas activation were able to be clearly identified. These experimental data will be very useful for the benchmark test of tag gas activation calculation applied to the fast reactor failed fuel detection. (author)

  5. Optically stimulated luminescence of MgB{sub 4}O{sub 7}:Ce,Li for gamma and neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Yukihara, E.G.; Doull, B.A.; Gustafson, T. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); Oliveira, L.C. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); Departamento de Física, FFCLRP-Universidade de São Paulo, 14040-901 Ribeirão Preto-SP (Brazil); Kurt, K. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); Mersin University Science and Letter Faculty Physics Department 33343 Mersin (Turkey); Milliken, E.D. [Physics Department, Oklahoma State University, Stillwater, OK 74078 (United States); R& D Pigments, Ferro Corporation, 251 W. Wylie Ave, Washington, PA 15301 (United States)

    2017-03-15

    The objective of this work was to develop a new optically stimulated luminescence (OSL) material for dosimetry applications that is tissue equivalent and has high sensitivity to ionizing radiation, fast luminescence lifetime, and intrinsic neutron sensitivity. To achieve this combination of properties, we started with a host material with low effective atomic number, MgB{sub 4}O{sub 7} (Z{sub eff}=8.2){sub ,} with an appropriate dopant characterized by short luminescence lifetime (Ce{sup 3+}). The samples were synthesized using Solution Combustion Synthesis with excess boric acid to achieve the correct crystallographic phase and Li co-doping to enhance its sensitivity. We investigated the thermoluminescence (TL) and OSL properties as a function of annealing temperature, radiation dose, dopant concentration, and time elapsed after irradiation (i.e., signal fading). We also applied a step-annealing procedure to investigate the depth of the trapping centers associated with the OSL signal. The samples obtained are characterized by a dominant TL peak at ~210 °C with intensity comparable to LiF:Mg,Ti. The OSL intensity is ~50% of that from Al{sub 2}O{sub 3}:C when using Hoya U-340 filters and shows no saturation up to almost 1 kGy. The OSL signal seems to originate from trapping center with stability > 150 °C, which means that the OSL fading is expected to be small. After the first day, in which fading associated with shallow traps is observed, fading of the total OSL signal was <4% within 6 days. The possibility of enhancing the neutron sensitivity was also demonstrated by synthesizing the material with enriched {sup 10}B. Although further development and characterization of the material may be needed, this work demonstrates that this host/dopant combination can be a viable alternative in OSL dosimetry, particularly for 2D dose mapping and neutron dosimetry applications.

  6. The Neutron Personal Dosimetry Service of the Centre for Radiation, Chemical and Environmental Hazards, PHE-UK; Servicio de Dosimetría Personal Neutrónica del Centro para Emergencias Radiológicas, Químicas y Medioambientales, PHE-UK

    Energy Technology Data Exchange (ETDEWEB)

    Campo Blanco, X.

    2015-07-01

    The Centre for Radiation, Chemical and Environmental Hazards (CRCEH), that belongs to Public Health England (PHE), hosts the official Neutron Personal Dosimetry Service of the United Kingdom. They use etched-track detectors, made of a material called PADC (poly-allyl diglycol carbonate), to determinate de neutron personal dose. A two weeks visit has been made to this center, in order to learn about the facilities, the methods employed and the legislative framework of the Neutron Personal Dosimetry Service. In this work the main results of this visits are shown, which are interesting for the future development of an official neutron personal dosimetry service in Spain.

  7. Validation of IRDFF in 252Cf Standard and IRDF-2002 Reference Neutron Fields

    Directory of Open Access Journals (Sweden)

    Simakov Stanislav

    2016-01-01

    Full Text Available The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f. and reference 235U(nth,f neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm IRDFF-1.03 in the 252Cf standard spontaneous fission spectrum; that was not the case for the current recommended spectra for 235U(nth,f. IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF-2002 collection. The ISNF facility was re-simulated to remove unphysical oscillations in the spectrum. IRDFF-1.03 was shown to reproduce reasonably well the spectrum-averaged data measured in these fields except for the case of YAYOI.

  8. Bubble detector's evaluation for neutron field measurement in a very known source

    Energy Technology Data Exchange (ETDEWEB)

    Ramalho, Eduardo; Silva, Ademir X. da, E-mail: ademir@nuclear.ufrj.b, E-mail: jdantas@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Reina, Luiz, E-mail: reina@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Facure, Alessandro, E-mail: facure@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Measurements on neutron fields, mainly for dosimetric purposes, have been a major concern for ionizing radiation workers, because of the radiation protection issues. The present work aims to study the using of bubble detectors in neutron dosimetry and the Bubble Detector Spectrometer (BDS) was chosen for this task. Several experiments were performed in order to obtain spectra from such devices and their respective analysis and then they were compared to those which were obtained by other ways. An Am-Be calibration neutron source from Instituto de Radioprotecao e Dosimetria/Comissao Nacional de Energia Nuclear (IRD/CNEN) was used and its spectrum was compared to the one obtained by BDS. The possibility of the use of such devices as ambient dosimeters was also evaluated. Despite the uncertainties, especially in the lowest energy thresholds, the spectrum from BDS is in good agreement with the known ones and the use of BDS as a dosimeter demands a more detailed study due to some characteristics of the Am-Be source that produce high uncertainties in low energy thresholds. (author)

  9. Response of six neutron survey meters in mixed fields of fast and thermal neutrons.

    Science.gov (United States)

    Kim, S I; Kim, B H; Chang, I; Lee, J I; Kim, J L; Pradhan, A S

    2013-10-01

    Calibration neutron fields have been developed at KAERI (Korea Atomic Energy Research Institute) to study the responses of commonly used neutron survey meters in the presence of fast neutrons of energy around 10 MeV. The neutron fields were produced by using neutrons from the (241)Am-Be sources held in a graphite pile and a DT neutron generator. The spectral details and the ambient dose equivalent rates of the calibration fields were established, and the responses of six neutron survey meters were evaluated. Four single-moderator-based survey meters exhibited an under-responses ranging from ∼9 to 55 %. DINEUTRUN, commonly used in fields around nuclear reactors, exhibited an over-response by a factor of three in the thermal neutron field and an under-response of ∼85 % in the mixed fields. REM-500 (tissue-equivalent proportional counter) exhibited a response close to 1.0 in the fast neutron fields and an under-response of ∼50 % in the thermal neutron field.

  10. Major upgrade of the reactor dosimetry interpretation methodology used at CEA. Architecture description

    International Nuclear Information System (INIS)

    Gregoire, Gilles; Destouches, Christophe; Beretz, Daniel; Bourganel, Stephane

    2009-01-01

    One of the main objectives of reactor dosimetry is the determination of the physical parameters characterizing the neutron field in which studied samples are irradiated. These values, from neutron spectrum to reaction rates are used on the one hand in experimental reactors to carry out the follow-up of the irradiation and to qualify the neutron calculation (modeling scheme for the experiment) and, on the other hand in power reactors for the follow-up of the damaging of vessel and internals. Neutron parameters are obtained from the treatment of dosimeter's activities which have suitable reactions (response functions and radioactive emissions). Then, activities are analyzed using nuclear data, neutron computation results and data characterizing the conditions of irradiation (temporal and technological data, changes of location...). This current interpretation process presents limitations coming mainly from the calculations tools and the nuclear data knowledge. But nowadays due to, first the improvement of the neutron calculation tools, a full 3D Monte Carlo reactor modeling providing reaction in a point wise format is now possible in a reasonable time, and second, recent releases of the international nuclear data libraries, JEFF3.1, ENDFB7 for transport calculation and IRDF2002 and EAF2007 for dosimetry libraries, a deep renewal of the reactor dosimetry interpretation process has been engaged. In addition, uncertainties associated to the results are derived in a rigorous way using simulation methods. This paper lists the main improvements of the neutron calculation codes and of the international nuclear data libraries. The principle of new interpretation process is then detailed. The general software architecture is then described, especially open-source tools chosen for the implementation. The paper finally analyzes expected improvements. (author)

  11. Neutron dosimetry for the TFTR Lithium-Blanket-Module program

    International Nuclear Information System (INIS)

    Harker, Y.D.; Tsang, F.Y.; Caffrey, A.J.; Homeyer, W.G.; Engholm, B.A.

    1981-01-01

    The Tokamak Fusion Test Reactor (TFTR) Lithium Blanket Module (LBM) program is a first-of-a-kind neutronics experiment involving a prototypical fusion reactor blanket module with a distributed neutron source from the plasma of the TFTR at Princeton Plasma Physics Laboratory. The objectives of the LBM program are: (1) to test the capabilities of neutron transport codes when applied to fusion test reactor blanket conditions, and (2) to obtain tritium breeding performance data on a typical design concept of a fusion-reactor blanket. This paper addresses the issues relative to the measurement of neutron fields in the LBM, presents the results of preliminary design studies concerning neutron measurements and also presents the results of blanket mockup experiments performed at the Idaho National Engineering Laboratory

  12. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  13. Reactor Dosimetry Aspects of the Service Life Extension of the Hungarian Paks NPP

    Directory of Open Access Journals (Sweden)

    Zsolnay Eva M.

    2016-01-01

    Full Text Available The service life of the Hungarian Paks Nuclear Power Plant (NPP will be extended from the originally planned 30 years to 50 years. To improve the reliability of the results obtained in frame of the old reactor pressure vessel (RPV surveillance programme, new methods have been developed, and based on them, the old exposition data have been re-evaluated for all the four reactor units. At the same time, a new RPV surveillance programme has been developed and introduced, and long term irradiations have been performed to determine the radiation damage of the surveillance specimens due to the high fast neutron exposition. Neutron transport calculations have been performed with a validated neutron transport code system to determine the fast neutron exposition of the RPVs during the extended service life. The cavity dosimetry is in the introductory phase. This paper presents the new developments in the field of the RPV surveillance dosimetry and summarises the results obtained. According to the results the service life of the NPP can safely be extended for the planned 50 years.

  14. Personnel-dosimetry intercomparison studies at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Sims, C.S.

    1982-01-01

    Since 1974, seven annual personnel dosimetry intercomparison studies have been conducted at the Oak Ridge National Laboratory using the Health Physics Reactor. These studies have produced more than 2000 measurements by 72 participating organizations of neutron and gamma dose equivalents between 0.1 to 15.0 mSv in six mixed radiation fields. The relative performance of three basic types of personnel neutron dosimeters (nuclear emulsion film, thermoluminescent, and track-etch) and two basic types of gamma dosimeters (film and thermoluminescent) was assessed based on experimental results obtained during the seven intercomparisons

  15. Study and development of radiothermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Portal, Guy.

    1978-11-01

    After briefly reviewing bibliography concerning the mechanism of radiothermoluminescence and its use in dosimetry, we have concentrated on studies of three thermoluminescent products: magnesium activated lithium fluoride, alumina and calcium sulfate activated with either dysprosium or thulium. In particular, the preparation and singular properties of a new type of lithium fluoride stabilised with sodium, created especially for dosimetric purposes, is described. The physical characteristics of these three products, their emission spectra and their trap parameters, have been studied and we have analysed, both theoretically and experimentally, their dosimetric properties, paying particular attention to their relative chromatic sensitivity to photons and neutrons. It is shown that alumina exhibits an exceptional neutron thermoluminescent yield which points to a potential interest in this material which is little used to date. The deep trapping levels of these products have been studied and some levels found appearing at temperatures above 600 0 C: these can be used for radiation dosimetry in enclosures at temperatures between 400 and 450 0 C. Finally, a brief outline of radiothermoluminescent applications of these products in the radioprotection, medical, biological, archeological and industrial fields is presented [fr

  16. Stereotactic radiosurgery photon field profile dosimetry using conventional dosimeters and polymer gel dosimetry. Analysis and inter-comparison

    Energy Technology Data Exchange (ETDEWEB)

    Pappas, E; Maris, T G; Zacharopoulou, F; Papadakis, A [Department of Medical Physics, Faculty of Medicine, University of Crete, 711 10 Stavrakia-Heraklion, Crete (Greece); Manolopoulos, S; Green, S [Queen Elizabeth Medical Centre, University Hospital Birmingham NHS Trust, Birmingham B15 2TH (United Kingdom); Wojnecki, C, E-mail: epappas@edu.med.uoc.gr

    2009-05-01

    Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. Accurate beam profile measurements of such beams are crucial for a precise and effective treatment. In this work four different dosimetric methods have been used for profile measurements of three small 6 MV circular fields having diameters of 7.5, 15.0 and 30.0 mm. A small sensitive volume air ion chamber, a diamond detector, a novel silicon-diode array and Vinyl-Pyrrolidone based polymer gel dosimetry. The results of this work reveal the well-known disadvantages and/or problems of the conventional dosimeters for this kind of measurements and support that polymer gel dosimetry may overcome these problems. Conclusively, it is estimated that polymer gels could play an important role towards the minimization of the total SRS/SRT treatment error that is related with small field profile measurements.

  17. Development of a silicon calorimeter for dosimetry applications in a water-moderated reactor

    International Nuclear Information System (INIS)

    DePriest, Kendall Russell; King, Donald Bryan; Naranjo, Gerald E.; Luker, Spencer Michael; Keltner, Ned R.; Suo-Anttila, Ahti Jorma; Griffin, Patrick Joseph

    2005-01-01

    High fidelity active dosimetry in the mixed neutron/gamma field of a research reactor is a very complex issue. For passive dosimetry applications, the use of activation foils addresses the neutron environment while the use of low neutron response CaF 2 :Mn thermoluminescent dosimeters (TLDs) addresses the gamma environment. While radiation-hardened diamond photoconducting detectors (PCD) have been developed that provide a very precise fast response (picosecond) dosimeter and can provide a time-dependent profile for the radiation environment, the mixed field response of the PCD is still uncertain and this interferes with the calibration of the PCD response. In order to address the research reactor experimenter's need for a dosimeter that reports silicon dose and dose rate at a test location during a pulsed reactor operation, a silicon calorimeter has been developed. This dosimeter can be used by itself to provide a dose in rad(Si) up to a point in a reactor pulsed operation, or, in conjunction with the diamond PCD, to provide a dose rate. This paper reports on the development, testing, and validation of this silicon calorimeter for applications in water-moderated research reactors.

  18. Test and validation of the iterative code for the neutrons spectrometry and dosimetry: NSDUAZ

    International Nuclear Information System (INIS)

    Reyes H, A.; Ortiz R, J. M.; Reyes A, A.; Castaneda M, R.; Solis S, L. O.; Vega C, H. R.

    2014-08-01

    In this work was realized the test and validation of an iterative code for neutronic spectrometry known as Neutron Spectrometry and Dosimetry of the Universidad Autonoma de Zacatecas (NSDUAZ). This code was designed in a user graph interface, friendly and intuitive in the environment programming of LabVIEW using the iterative algorithm known as SPUNIT. The main characteristics of the program are: the automatic selection of the initial spectrum starting from the neutrons spectra catalog compiled by the International Atomic Energy Agency, the possibility to generate a report in HTML format that shows in graph and numeric way the neutrons flowing and calculates the ambient dose equivalent with base to this. To prove the designed code, the count rates of a spectrometer system of Bonner spheres were used with a detector of 6 LiI(Eu) with 7 polyethylene spheres with diameter of 0, 2, 3, 5, 8, 10 and 12. The count rates measured with two neutron sources: 252 Cf and 239 PuBe were used to validate the code, the obtained results were compared against those obtained using the BUNKIUT code. We find that the reconstructed spectra present an error that is inside the limit reported in the literature that oscillates around 15%. Therefore, it was concluded that the designed code presents similar results to those techniques used at the present time. (Author)

  19. Personnel neutron dosimetry applications of track-size distributions on electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1988-01-01

    The track-size distribution on electrochemically etched CR-39 foils can be used to obtain some limited information on the incident neutron spectra. Track-size distributions on CR-39 foils can also be used to determine if the tracks were caused by neutrons or if they are merely background tracks (which have a significantly different track-size distribution). Identifying and discarding the high-background foils reduces the number of foils that must be etched. This also lowers the detection limit of the dosimetry system. We have developed an image analyzer program that can more efficiently determine the track density and track-size distribution, as well as read the laser-cut identification numbers on each foil. This new image analyzer makes the routine application of track-size distributions on CR-39 foils feasible. 2 refs., 3 figs

  20. Dosimetry of irregular shaped fields of β rays

    International Nuclear Information System (INIS)

    Supe, S.J.; Datta, S.

    1976-01-01

    The feasibility of using various shapes and sizes of field limiting devices and collimators with β-ray eye applicators has necessitated the study of dosimetry for these fields. A method of calculating surface and depth doses for any shaped field from the data for circular fields is presented. The depth dose evaluation is based on a measured dose function which is defined as the dose rate at a particular depth for a particular circular field. The evaluated values for the surface and depth dose were compared with experimentally obtained values for three non-circular fields. The good agreement in these data indicates the practicability of the method suggested. (author)

  1. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    Science.gov (United States)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the

  2. Test of an albedo neutron dosimetry system: TLD calibration and readout procedure, neutron calibration, dosimetry properties, routine application

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1988-03-01

    The two-component albedo dosemeter in use consists of an universal boron-loaded plastic encapsulation, the beta and albedo neutron windows of which are adopted to the corresponding TLD system of the manufacturers Alnor, Harshaw, Panasonic and Vinten. Beside the TLD detectors the capsule may contain also track etch detectors. Within a BMU project the system was investigated by four governmental measurement services in the FRG with respect to its qualification for personnel monitoring with emphasis in the readout and calibration procedures for the TLD system, the evaluation technique for the estimation of the photon and neutron dose equivalent in routine monitoring and the calibration of the personnel dosemeter in stray neutron fields. The test has shown the readiness of the system to act in the application areas of nuclear power reactors and linacs behind heavy shieldings, in the fuel element cycle, use of fissile materials, criticality, use of radionuclide sources, high energy particle accelerators. The uncertainty due to energy dependence was found to be within a factor of 2 for a single application area. In the case of irradiations from the front half space the dose equivalent H'(10) is indicated sufficiently independent of the direction of the radiation incidence. After completion of the test the albedo dosemeter became the official neutron personnel dosemeter in the FRG. It allows the separate estimation of the dose equivalent of hard beta radiation, photon radiation and neutrons. (orig./HP) [de

  3. Organisation of a laboratory of photographic dosimetry

    International Nuclear Information System (INIS)

    Soudain, Georges

    1961-01-01

    After a recall of the main properties of photographic dosimetry, the author describes the principle of this method, and comments the issue of chromatic sensitivity of photographic emulsions. He discusses the calibration process for gamma radiation, X rays, and thermal neutrons. He describes how fast neutron dosimetry is performed. In the next part, he describes the organisation of the photometry laboratory which has to prepare and distribute dosimeters, to collect and exploit them, and to prepare a publication of results. These different missions and tasks are described

  4. Design characteristics of a three-component AEOI Neutriran Albedo Neutron Personnel Dosimeter

    International Nuclear Information System (INIS)

    Sohrabi, M.; Katouzi, M.

    1991-01-01

    In establishing a national personnel neutron dosimetry service in Iran, different parameters of the AEOI Neutriran Albedo Neutron Personnel Dosimeter (NANPD) have been optimized. A NANPD was designed with three dosimetry components to measure (a) direct thermal neutrons, (b) direct fast neutrons and (C) direct neutrons by the detection of the albedo neutrons reflected from the body. The dosimeter consists of one or more Lexan polycarbonate and/or CR-39 foils and two 10 B (n,α) 7 Li converters in a cadmium cover so arranged as to efficiently measure the three neutron dose components separately. The boron converter thickness, its position relative to the beam direction and its distance from the PC foil were studied and the results were incorporated into the design. The dose response of the dosimeter, its lower detection limit as well as the correction factors related to the field neutrons and albedo neutrons were also determined for a 238 Pu-Be, an 241 Am-Be and a 252 Cf sources. In this paper, the dosimeter design and its dosimetric characteristics are presented and discussed. (author)

  5. Monte Carlo based dosimetry and treatment planning for neutron capture therapy of brain tumors

    International Nuclear Information System (INIS)

    Zamenhof, R.G.; Clement, S.D.; Harling, O.K.; Brenner, J.F.; Wazer, D.E.; Madoc-Jones, H.; Yanch, J.C.

    1990-01-01

    Monte Carlo based dosimetry and computer-aided treatment planning for neutron capture therapy have been developed to provide the necessary link between physical dosimetric measurements performed on the MITR-II epithermal-neutron beams and the need of the radiation oncologist to synthesize large amounts of dosimetric data into a clinically meaningful treatment plan for each individual patient. Monte Carlo simulation has been employed to characterize the spatial dose distributions within a skull/brain model irradiated by an epithermal-neutron beam designed for neutron capture therapy applications. The geometry and elemental composition employed for the mathematical skull/brain model and the neutron and photon fluence-to-dose conversion formalism are presented. A treatment planning program, NCTPLAN, developed specifically for neutron capture therapy, is described. Examples are presented illustrating both one and two-dimensional dose distributions obtainable within the brain with an experimental epithermal-neutron beam, together with beam quality and treatment plan efficacy criteria which have been formulated for neutron capture therapy. The incorporation of three-dimensional computed tomographic image data into the treatment planning procedure is illustrated. The experimental epithermal-neutron beam has a maximum usable circular diameter of 20 cm, and with 30 ppm of B-10 in tumor and 3 ppm of B-10 in blood, it produces a beam-axis advantage depth of 7.4 cm, a beam-axis advantage ratio of 1.83, a global advantage ratio of 1.70, and an advantage depth RBE-dose rate to tumor of 20.6 RBE-cGy/min (cJ/kg-min). These characteristics make this beam well suited for clinical applications, enabling an RBE-dose of 2,000 RBE-cGy/min (cJ/kg-min) to be delivered to tumor at brain midline in six fractions with a treatment time of approximately 16 minutes per fraction

  6. Calibration of a TLD system to estimate personal doses in fields of gamma-neutrons radiation

    International Nuclear Information System (INIS)

    Villegas, E.N.; Somarriba, S.I.

    2016-01-01

    Currently Nicaragua has no personal neutron dosimetry system. The calibration of a batch of albedo neutron dosimeters consisting of two pairs of "6LiF and "7LiF (Mg, Ti) detectors was done. The dosimeter and reader sensitivities were obtained using a "1"3"7Cs source, and a neutron calibration factor was found with a "2"4"1AmBe source. Reproducibility and homogeneity tests were performed, and the detection limit of the system was determined. This calibration will allow the beginning of neutron personal monitoring in the country. (author)

  7. Thermoluminescence fast neutron dosimetry by laser heating

    International Nuclear Information System (INIS)

    Mathur, V.K.; Brown, M.D.; Braeunlich, P.

    1984-01-01

    Heating rates in excess of 10 4 K.sec -1 have been achieved for thin layers of TL dosemeters by laser heating. The high heating rate improves the signal to noise ratio up to a factor of 10 3 . Thus sensitive thin film fast neutron dosemeters with negligible self-shielding have become a practical reality. Thin samples of CaSO 4 :Dy have been investigated for their response to fast neutrons from a Pu-Be source and a 14.6 MeV neutron generator by using a hydrogenous radiator. A 15 watt CO 2 laser was focussed on the thin TLD layer to a spot size of less than 1 mm to heat it. An exposure of a few tens of milliseconds was sufficient to obtain a TLD curve, which was displayed and processed by a wave form digitiser. The laser spot could be scanned over the TLD sample by a x-y positioner and a large number of observations were obtained on each sample. Preliminary results show that it is possible to obtain a figure of merit of approx. 5% in a mixed n, γ field. A practical design for a fast neutron dosemeter is proposed. (author)

  8. Evaluation of area monitor response for neutrons in radiation field generated by a 15 MV clinic accelerator

    International Nuclear Information System (INIS)

    Salgado, Ana Paula

    2011-01-01

    The clinical importance and usage of linear accelerators in cancer treatment increased significantly in the last years. Coupled with this growth came the concern about the use of accelerators with energies over to 10 MeV which produce therapeutic beam contaminated with neutrons generated when high-energy photons interact with high-atomic-number materials such as tungsten and lead present in the accelerator itself. At these facilities, measurements of the ambient dose equivalent for neutrons present difficulties owing to the existence of a mixed radiation field and possible electromagnetic interference near the accelerator. The Neutron Laboratory of the IRD - Brazilian Institute for Radioprotection and Dosimetry, aiming to evaluate the survey meters performance at these facilities, initiated studies of instrumentation response in the presence of different neutron spectra. Neutrons sources with average energies ranging from 0.55 to 4.2 MeV, four different survey meters and one ionization chamber to obtain the ratio between the dose due to neutrons and gamma radiation were used in this work. The evaluation of these measurements, performed in a 15 MV linear accelerator room is presented. This work presents results that demonstrate the complexity and care needed to make neutrons measurements in radiotherapy treatment rooms containing high energy clinical accelerators. (author)

  9. Polarized neutron reflectometry in high magnetic fields

    International Nuclear Information System (INIS)

    Fritzsche, H.

    2005-01-01

    A simple method is described to maintain the polarization of a neutron beam on its way through the large magnetic stray fields produced by a vertical field of a cryomagnet with a split-coil geometry. The two key issues are the proper shielding of the neutron spin flippers and an additional radial field component in order to guide the neutron spin through the region of the null point (i.e., point of reversal for the vertical field component). Calculations of the neutron's spin rotation as well as polarized neutron reflectometry experiments on an ErFe 2 /DyFe 2 multilayer show the perfect performance of the used setup. The recently commissioned cryomagnet M5 with a maximum vertical field of up to 7.2 T in asymmetric mode for polarized neutrons and 9 T in symmetric mode for unpolarized neutrons was used on the C5 spectrometer in reflectometry mode, at the NRU reactor in Chalk River, Canada

  10. High-energy quasi-monoenergetic neutron fields: existing facilities and future needs

    CERN Document Server

    Pomp, S; Mayer, S; Reitz, G; Rottger, S; Silari, M; Smit, F D; Vincke, H; Yasuda, H

    2014-01-01

    The argument that well-characterised quasi-monoenergetic neutron (QMN) sources reaching into the energy domain >20 MeV are needed is presented. A brief overview of the existing facilities is given, and a list of key factors that an ideal QMN source for dosimetry and spectrometry should offer is presented. The authors conclude that all of the six QMN facilities currently in existence worldwide operate in sub-optimal conditions for dosimetry. The only currently available QMN facility in Europe capable of operating at energies >40 MeV, TSL in Uppsala, Sweden, is threatened with shutdown in the immediate future. One facility, NFS at GANIL, France, is currently under construction. NFS could deliver QMN beams up to about 30 MeV. It is, however, so far not clear if and when NFS will be able to offer QMN beams or operate with only so-called white neutron beams. It is likely that by 2016, QMN beams with energies >40 MeV will be available only in South Africa and Japan, with none in Europe.

  11. Fast neutron dosimetry. Progress report, July 1, 1978-June 30, 1979. Wisconsin Medical Physics report No. WMP-109

    International Nuclear Information System (INIS)

    Attix, F.H.

    1979-01-01

    Research activities relating to neutron dosimetry at the University of Wisconsin conducted between 1961 and 1979 are comprehensively reviewed. Former principal investigators discuss the activities and accomplishments which occurred during their tenure, and the current principal investigator discusses future plans. Seven reprints of papers dealing with specific aspects of the program are included in the report, but have not been indexed separately

  12. Guidelines on calibration of neutron measuring devices

    International Nuclear Information System (INIS)

    Burger, G.

    1988-01-01

    The International Atomic Energy Agency and the World Health Organization have agreed to establish an IAEA/WHO Network of Secondary Standard Dosimetry Laboratories (SSDLs) in order to improve accuracy in applied radiation dosimetry throughout the world. These SSDLs must be equipped with, and maintain, secondary standard instruments, which have been calibrated against primary standards, and must be nominated by their governments for membership of the network. The majority of the existing SSDLs were established primarily to work with photon radiation (X-rays and gamma rays). Neutron sources are, however, increasingly being applied in industrial processes, research, nuclear power development and radiation biology and medicine. Thus, it is desirable that the SSDLs in countries using neutron sources on a regular basis should also fulfil the minimum requirements to calibrate neutron measuring devices. It is the primary purpose of this handbook to provide guidance on calibration of instruments for radiation protection. A calibration laboratory should also be in a position to calibrate instrumentation being used for the measurement of kerma and absorbed dose and their corresponding rates. This calibration is generally done with photons. In addition, since each neutron field is usually contaminated by photons produced in the source or by scatter in the surrounding media, neutron protection instrumentation has to be tested with respect to its intrinsic photon response. The laboratory will therefore need to possess equipment for photon calibration. This publication deals primarily with methods of applying radioactive neutron sources for calibration of instrumentation, and gives an indication of the space, manpower and facilities needed to fulfil the minimum requirements of a calibration laboratory for neutron work. It is intended to serve as a guide for centres about to start on neutron dosimetry standardization and calibration. 94 refs, 8 figs, 12 tabs

  13. Dosimetry of fission neutrons in a 1-W reactor, UTR-KINKI

    CERN Document Server

    Endo, S; Yoshitake, Y

    2002-01-01

    The energy spectrum of fission neutrons in the biological irradiation field of the Kinki University reactor, UTR-KINKI, has been determined by a multi-foil activation analysis coupled with artificial neural network techniques and a Au-foil activation method. The mean neutron energy was estimated to be 1.26+-0.05 MeV from the experimentally determined spectrum. Based on this energy value and other information, the neutron dose rate was estimated to be 19.7+-1.4 cGy/hr. Since this dose rate agrees with that measured by a pair of ionizing chambers (21.4 cGy/hr), we conclude that the mean neutron energy could be estimated with reasonable accuracy in the irradiation field of UTR-KINKI. (author)

  14. Pressure-vessel surveillance dosimetry using solid-state track recorders

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Gold, R.; Roberts, J.H.

    1981-01-01

    In addition to radiometric and SSTR dosimetry sets, helium accumulation fluence monitors, damage monitors, and temperature monitors are being studied. The ideal dosimetry set would monitor neutron fluence, damage, and temperature with as few materials as possible in order to reduce costs and required space. It is hoped that materials such as quartz SSTR and sapphire damage monitors can be developed as multipurpose materials. Sapphire for instance, might be used as a combined fluence and damage monitor (for example, analyzed for helium accumulation, Np 237 fissions, and direct neutron damage). Continuing research will result in the optimization of dosimetry packages for use in long term surveillance of LWR Pressure Vessels

  15. To the use of bubble detectors in personal neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Spurny, F; Vlcek, B [Academy of the Sciences of Czech Republic, Prague (Czech Republic). Nuclear Physics Institute, Department of Radiation Dosimetry

    1996-12-31

    In this paper the commercially available bubble neutron detectors (bubble damage neutron detectors (BDNDs*) from Bubble Technology Industries, Chalk River; and superheated drop detectors (SDDs*) from APFEL Industries, New Haven) for lowest limit of detection of an individual neutron dosimeter were tested. They were tested with the different neutron sources. BDNDs* tested had the sensitivity about 1 bubble per 1 Sv of H*(10) of AmBe neutrons, they were evaluated by eye counting (20 to 30 bubbles per detector). Two types of reusable BDNDs* were tested: BD-100R without and with temperature compensation, both with neutron energy threshold about 100 keV. SDDs* tested had the sensitivity about 3 bubbles per 1 {mu}Sv of H*10 from AmBe neutrons, they were evaluated using APFEL Survey Meter Model 202. SDDs* with three different energy thresholds have been used: 0.1, 1 and 6 MeV. For energetical dependence of BDNDs* the general conclusions were formulated in the following way: (1) With the exception of thermal neutron source SIGMA (50% of H*(10) from thermal neutrons) and high energy reference fields there is a reasonable agreement of data measured with BDNDs* and expected values; (2) the new lots to have a little different energetic dependence. The relative responses for `soft` fields are for them systematically higher than for previous samples. The response to energies between 0.01 and 1 MeV is for these lots relatively higher. (3) The underestimation of high energy neutrons is typical for any LET-threshold type detectors.It should be kept in mind when BDNDs* are used as dosemeters in high energy neutron environment. For energetical dependence of SDDs* was concluded: (1) The energetical dependence of SDD 100 is comparable with the dependencies of BD-100R and PND, the underestimation of high energy neutrons included; (2) The use of SDD with different energy thresholds can provide interesting spectrometric information; (Abstract Truncated)

  16. Development of a TPC for energy and fluence references in low energies neutronic fields (from 8 keV to 5 MeV)

    International Nuclear Information System (INIS)

    Maire, Donovan

    2015-01-01

    In order to judge the measurement reliability, metrology requires to measure quantities with their uncertainties, in relation to a reference through a documented and unbroken chain of calibrations. In neutron radiation field, instrument response has to be known as a function of the neutron energy. Then detector calibrations are required using reference neutron fields. In France, primary reference neutron fields are held by the LNE-IRSN, at the Laboratory for Neutron Metrology and Dosimetry (LMDN). In order to improve reference neutron field characterization, the LNE-IRSN MIMAC μTPC has been developed. This detector is a Time Projection Chamber (TPC), using a gas at low pressure (30 mbar abs. to 1 bar abs.). Nuclear recoils are generated by neutron elastic scattering onto gas atoms. By measuring the nuclear recoil energy and scattering angle, the μTPC detector is able to measure the energy distribution of the neutron fluence between 8 keV and 5 MeV. The main challenge was to perform accurate spectrometry of neutron fields in the keV range, following a primary procedure. First of all, a metrological approach was followed in order to master every physical process taking part in the neutron detection. This approach led to develop the direct and inverse models, representing the detector response function and its inverse function respectively. Using this detailed characterization, the energy distribution of the neutron fluence has been measured for a continuous neutron field of 27 keV. The reconstructed energy is 28,2 ± 4,5 keV, the difference between μTPC integral fluence measurement and other measurement methods is less than 6%. The LNE-IRSN MIMAC μTPC system becomes the only one system able to measure simultaneously energy and fluence at energies lower than 100 keV, following a primary procedure. The project goal is then reached. These measurements at energies lower than 100 keV shows also a non-linearity between the ionization charge and the ion kinetic energy

  17. EURADOS intercomparison 2012 for neutron dosemeters

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Chevallier, M.A.; Cruz-Suarez, R.; Luszik-Bhadra, M.; Mayer, S.; Thomas, D.J.; Tanner, R.; Vanhavere, F.

    2014-11-01

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ( 252 Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ( 252 Cf at 45 ) or for simulated workplace fields ( 252 Cf(D 2 O) or 252 Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection principle on which the

  18. SU-E-T-75: Commissioning Optically Stimulated Luminescence Dosimeters for Fast Neutron Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Young, L [UniversityWashington, Seattle, WA (United States); Yang, F; Sandison, G [University of Washington, Seattle, WA (United States); Woodworth, D [University of California, Santa Barbara, Santa Barbara, CA (United States); McCormick, Z [University of Nevada - Reno, Reno, Nevada (United States)

    2014-06-01

    Purpose: Fast neutrons therapy used at the University of Washington is clinically proven to be more effective than photon therapy in treating salivary gland and other cancers. A nanodot optically stimulated luminescence (OSL) system was chosen to be commissioned for patient in vivo dosimetry for neutron therapy. The OSL-based radiation detectors are not susceptible to radiation damage caused by neutrons compared to diodes or MOSFET systems. Methods: An In-Light microStar OSL system was commissioned for in vivo use by radiating Landauer nanodots with neutrons generated from 50.0 MeV protons accelerated onto a beryllium target. The OSLs were calibrated the depth of maximum dose in solid water localized to 150 cm SAD isocenter in a 10.3 cm square field. Linearity was tested over a typical clinical dose fractionation range i.e. 0 to 150 neutron-cGy. Correction factors for transient signal fading, trap depletion, gantry angle, field size, and wedge factor dependencies were also evaluated. The OSLs were photo-bleached between radiations using a tungsten-halogen lamp. Results: Landauer sensitivity factors published for each nanodot are valid for measuring photon and electron doses but do not apply for neutron irradiation. Individually calculated nanodot calibration factors exhibited a 2–5% improvement over calibration factors computed by the microStar InLight software. Transient fading effects had a significant impact on neutron dose reading accuracy compared to photon and electron in vivo dosimetry. Greater accuracy can be achieved by calibrating and reading each dosimeter within 1–2 hours after irradiation. No additional OSL correction factors were needed for field size, gantry angle, or wedge factors in solid water phantom measurements. Conclusion: OSL detectors are a useful for neutron beam in vivo dosimetry verification. Dosimetric accuracy comparable to conventional diode systems can be achieved. Accounting for transient fading effects during the neutron beam

  19. Hyper-thermal neutron irradiation field for neutron capture therapy

    International Nuclear Information System (INIS)

    Sakurai, Yoshinori; Kobayashi, Tooru; Kanda, Keiji

    1994-01-01

    The utilization of hyper-thermal neutrons, which have an energy spectrum of a Maxwell distribution higher than the room temperature of 300 K, has been studied in order to improve the thermal neutron flux distribution in a living body for a deep-seated tumor in neutron capture therapy (NCT). Simulation calculations using MCNP-V3 were carried out in order to investigate the characteristics of the hyper-thermal neutron irradiation field. From the results of simulation calculations, the following were confirmed: (i) The irradiation field of the hyper-thermal neutrons is feasible by using some scattering materials with high temperature, such as Be, BeO, C, SiC and ZrH 1.7 . Especially, ZrH 1.7 is thought to be the best material because of good characteristics of up-scattering for thermal neutrons. (ii) The ZrH 1.7 of 1200 K yields the hyper-thermal neutrons of a Maxwell-like distribution at about 2000 K and the treatable depth is about 1.5 cm larger comparing with the irradiation of the thermal neutrons of 300 K. (iii) The contamination by the secondary gamma-rays from the scattering materials can be sufficiently eliminated to the tolerance level for NCT through the bismuth layer, without the larger change of the energy spectrum of hyper-thermal neutrons. ((orig.))

  20. Next decade in external dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1988-01-01

    In recent years, a number of external dosimetry problems have been solved. However, changes in standards and legal concepts relating to the application of dosimetry results will require further enhancements in measurement techniques and philosophy in the next 10 y. The introduction of effective dose equivalent and the legal use of probability of causation will require that much greater attention be given to determination of weighted organ dose from external exposure. An imminent change--an increase in the fast neutron quality factor--will require a new round of technology development in a field that has just received a decade of close scrutiny. For the future, we must take advantage of developments in microelectronics. The use of random access memory (RAM) and metal-on-silicon (MOS) devices as detector elements, particularly for neutron dosimetry, has exciting possibilities that are just beginning to be explored. Advances in microcircuitry are leading, and will continue to lead, in the development of a new generation of small, rugged and smart radiation survey instruments that will make the most of detector data. It has become possible with very compact instruments to obtain energy spectra, linear-energy-transfer (LET) spectra, and quality factors in addition to the usual integrated dosimetric quantities: exposure, absorbed dose, and dose equivalent. These instruments will be reliable and easy to use. The user will be able to select the level of sophistication that is required for any specific application. Moreover, since the processing algorithms can be changed, changes in conversion factors can be accommodated with relative ease. During the next decade, the use of computers will continue to grow in value to the health physicist

  1. Solid-state track recorder neutron dosimetry in light water reactor pressure vessel surveillance mockups

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Roberts, J.H.; Gold, R.; Preston, C.C.

    1984-09-01

    Solid-State Track Recorder (SSTR) measurements of neutron-induced fission rates have been made in several pressure vessel mockup facilities as part of the US Nuclear Regulatory Commission's (NRC) Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Program (LWR-PV-SDIP). The results of extensive physics-dosimetry measurements made at the Pool Critical Assembly (PCA) at Oak Ridge National Laboratory (ORNL) in Oak Ridge, TN are summarized. Included are 235 U, 238 U, 237 Np and 232 Th fission rates in the PCA 12/13, 8/7, and 4/12 SSC configurations. Additional low power measurements have been made in an engineering mockup at the VENUS critical assembly at CEN-SCK, Mol, Belgium. 237 Np and 238 U fission rates were made at selected locations in the VENUS mockup, which models the in-core and near-core regions of a pressurized water reactor (PWR). Absolute core power measurements were made at VENUS by exposing solid-state track recorders (SSTRs) to polished fuel pellets within in-core fuel pins. 8 references, 4 figures, 10 tables

  2. Evaluation of room-scattered neutrons at the JNC Tokai neutron reference field

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Tadayoshi; Tsujimura, Norio [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan). Tokai Works; Oyanagi, Katsumi [Japan Radiation Engineering Co., Ltd., Hitachi, Ibaraki (Japan)

    2002-09-01

    Neutron reference fields for calibrating neutron-measuring devices in JNC Tokai Works are produced by using radionuclide neutron sources, {sup 241}Am-Be and {sup 252}Cf sources. The reference field for calibration includes scattered neutrons from the material surrounding sources, wall, floor and ceiling of the irradiation room. It is, therefore, necessary to evaluate the scattered neutrons contribution and their energy spectra at reference points. Spectral measurements were performed with a set of Bonner multi-sphere spectrometers and the reference fields were characterized in terms of spectral composition and the fractions of room-scattered neutrons. In addition, two techniques stated in ISO 10647, the shadow-cone method and the polynomial fit method, for correcting the contributions from the room-scattered neutrons to the readings of neutron survey instruments were compared. It was found that the two methods gave an equivalent result within a deviation of 3.3% at a source-to-detector distance from 50cm to 500cm. (author)

  3. Evaluation of room-scattered neutrons at the JNC Tokai neutron reference field

    International Nuclear Information System (INIS)

    Yoshida, Tadayoshi; Tsujimura, Norio

    2002-01-01

    Neutron reference fields for calibrating neutron-measuring devices in JNC Tokai Works are produced by using radionuclide neutron sources, 241 Am-Be and 252 Cf sources. The reference field for calibration includes scattered neutrons from the material surrounding sources, wall, floor and ceiling of the irradiation room. It is, therefore, necessary to evaluate the scattered neutrons contribution and their energy spectra at reference points. Spectral measurements were performed with a set of Bonner multi-sphere spectrometers and the reference fields were characterized in terms of spectral composition and the fractions of room-scattered neutrons. In addition, two techniques stated in ISO 10647, the shadow-cone method and the polynomial fit method, for correcting the contributions from the room-scattered neutrons to the readings of neutron survey instruments were compared. It was found that the two methods gave an equivalent result within a deviation of 3.3% at a source-to-detector distance from 50cm to 500cm. (author)

  4. Remarks concerning the accurate measurement of differential cross sections for threshold reactions used in fast-neutron dosimetry for fission reactors

    International Nuclear Information System (INIS)

    Smith, D.L.

    1976-12-01

    Some remarks are submitted concerning the measurement of differential cross sections for threshold reactions which are used in fast-neutron dosimetry for fission reactors. The objective is to familiarize the reader with some of the problems associated with these measurements and, in the process, to explain why the existence of large discrepancies in the data sets for many of these reactions is not surprising. Limits to the accuracy which can be expected for these cross sections in the near future--using current technology and available resources--are examined in a general way and recommendations for improving the accuracy of the differential data base for dosimetry reactions are presented

  5. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector.

    Science.gov (United States)

    Morales, Johnny E; Crowe, Scott B; Hill, Robin; Freeman, Nigel; Trapp, J V

    2014-11-01

    Small field x-ray beam dosimetry is difficult due to lack of lateral electronic equilibrium, source occlusion, high dose gradients, and detector volume averaging. Currently, there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Small field sizes were defined by BrainLAB circular cones (4-30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses (PDDs) were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated by Monte Carlo methods using BEAMnrc and correction factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. For the small fields of 4-30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. The authors conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.

  6. Tenth ORNL Personnel Dosimetry Intercomparison Study

    International Nuclear Information System (INIS)

    Swaja, R.E.; Chou, T.L.; Sims, C.S.; Greene, R.T.

    1985-03-01

    The Tenth Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory during April 9-11, 1984. Dosemeter badges from 31 participating organizations were mounted on 40cm Lucite phantoms and exposed to a range of dose equivalents which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor served as the only source of radiation for eight of the ten irradiations which included a low (approx. 0.50 mSv) and high (approx. 10.00 mSv) neutron dose equivalent run for each of four shield conditions. Two irradiations were also conducted for which concrete- and Lucite-shield reactor irradiations were gamma-enhanced using a 137 Cs source. Results indicated that some participants had difficulty obtaining measurable indication of neutron and gamma exposures at dose equivalents less than about 0.50 mSv and 0.20 mSv, respectively. Albedo dosemeters provided the best overall accuracy and precision for the neutron measurements. Direct interaction TLD systems showed significant variation in accuracy with incident spectrum, and threshold neutron dosemeters (film and recoil track) underestimated reference values by more than 50%. Gamma dose equivalents estimated in the mixed fields were higher than reference values with TL gamma dosemeters generally yielding more accurate results than film. Under the conditions of this study in which participants had information concerning exposure conditions and radiation field characteristics prior to dosemeter evaluation, only slightly more than half of all reported results met regulatory standards for neutron and gamma accuracy. 19 refs., 2 figs., 29 tabs

  7. Albedo Neutron Dosimetry in a Deep Geological Disposal Repository for High-Level Nuclear Waste.

    Science.gov (United States)

    Pang, Bo; Becker, Frank

    2017-04-28

    Albedo neutron dosemeter is the German official personal neutron dosemeter in mixed radiation fields where neutrons contribute to personal dose. In deep geological repositories for high-level nuclear waste, where neutrons can dominate the radiation field, it is of interest to investigate the performance of albedo neutron dosemeter in such facilities. In this study, the deep geological repository is represented by a shielding cask loaded with spent nuclear fuel placed inside a rock salt emplacement drift. Due to the backscattering of neutrons in the drift, issues concerning calibration of the dosemeter arise. Field-specific calibration of the albedo neutron dosemeter was hence performed with Monte Carlo simulations. In order to assess the applicability of the albedo neutron dosemeter in a deep geological repository over a long time scale, spent nuclear fuel with different ages of 50, 100 and 500 years were investigated. It was found out, that the neutron radiation field in a deep geological repository can be assigned to the application area 'N1' of the albedo neutron dosemeter, which is typical in reactors and accelerators with heavy shielding. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Electron paramagnetic resonance biophysical radiation dosimetry with tooth enamel

    International Nuclear Information System (INIS)

    Khan, Rao F.H.

    2003-01-01

    This thesis deals with the advancements made in the field of Electron Paramagnetic Resonance (EPR) for biophysical dosimetry with tooth enamel for accident, emergency, and retrospective radiation dose reconstruction. A methodology has been developed to measure retrospective radiation exposures in human tooth enamel. This entails novel sample preparation procedures with minimum mechanical treatment to reduce the preparation induced uncertainties, establish optimum measurement conditions inside the EPR cavity, post-process the measured spectrum with functional simulation of dosimetric and other interfering signals, and reconstruct dose. By using this technique, retrospective gamma exposures as low as 80±30 mGy have been successfully deciphered. The notion of dose modifier was introduced in EPR biodosimetry for low dose measurements. It has been demonstrated that by using the modified zero added dose (MZAD) technique for low radiation exposures, doses in 100 mGy ranges can be easily reconstructed in teeth that were previously thought useless for EPR dosimetry. Also, the use of a dose modifier makes robust dose reconstruction possible for higher radiation exposures. The EPR dosimetry technique was also developed for tooth samples extracted from rodents, which represent small tooth sizing. EPR doses in the molars, extracted from the mice irradiated with whole body exposures, were reassessed and shown to be correct within the experimental uncertainty. The sensitivity of human tooth enamel for neutron irradiation, obtained from the 3 MV McMaster K.N. Van de Graaff accelerator, was also studied. For the first time this work has shown that the neutron sensitivity of the tooth enamel is approximately 1/10th of the equivalent gamma sensitivity. Parametric studies for neutron dose rate and neutron energy within the available range of the accelerator, showed no impact on the sensitivity of the tooth enamel. Therefore, tooth enamel can be used as a dosimeter for both neutrons

  9. Certification of a copper metal reference material for neutron dosimetry. (EC nuclear reference material 522)

    International Nuclear Information System (INIS)

    Ingelbrecht, C.; Pauwels, J.; Lievens, F.

    1993-01-01

    Copper metal of ≥ 99.995% nominal purity in the form of 0.1 and 1.0 mm thick foil and 0.5 and 1.0 mm diameter wire has been certified for its cobalt and silver mass fractions. The certified values are -1 and 0.95 ± 0.04 mg.kg -1 respectively, based on 66 results for cobalt and 88 results for silver obtained by nine laboratories using three methods. This reference material, EC-NRM 522, is intended for reactor neutron dosimetry. (authors). 14 refs., 1 annexe, 10 tabs., 2 figs

  10. Results from 2010 Caliban Criticality Dosimetry Intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K. G.

    2011-10-12

    The external dosimetry program participated in a criticality dosimetry intercomparison conducted at the Caliban facility in Valduc, France in 2010. Representatives from the dosimetry and instrumentation groups were present during testing which included irradiations of whole-body beta/gamma (HBGT) and neutron thermoluminescent dosimeters (TLDs), a fixed nuclear accident dosimeter (FNAD), electronic alarming dosimeters, and a humanoid phantom filled with reference man concentrations of sodium. This report reviews the testing procedures, preparations, irradiations, and presents results of the tests.

  11. Scientific days on electromagnetic fields: from dosimetry to human health - Conference proceedings

    International Nuclear Information System (INIS)

    Wiart, J.; Ghanmi, A.; Picon, O.; Conil, E.; Varsier, N.; Hadjem, A.; Sudret, B.; Magne, I.; Souques, M.; Gaudaire, F.; De Seze, R.; Jawad, O.; Lautru, D.; Dricot, J.M.; Horlin, F.; De Doncker, P.; Drissaoui, A.; Musy, F.; Nicolas, L.; Perrussel, R.; Scorretti, R.; Voyer, D.; Jala, M.; Moulines, E.; Levy-Leduc, C.; Mahfouz, Z.; Gati, A.; Fouad Hanna, V.; Leveque, P.; Arnaud-Cormos, D.; Zhadobov, M.; Jarrige, P.; Gaborit, G.; Kohler, S.; Ticaud, N.; Duvillaret, L.; Guelilia, Z.; Loison, R.; Gillard, R.; Laisne, A.; Favet, D.; Benadhira, R.; Mir, L.; Nadi, M.; Kourtiche, D.; Gazeau, F.; Wilhelm, C.; Delemotte, L.; Breton, M.; Tarek, M.; Marc-Vergnes, J.P.; Yardin, C.; Perrin, A.; Le Drean, Y.; Sauleau, R.; Lambrozo, J.; Selmaoui, B.; Ghosn, R.; Thuroczy, G.; Villegier, A.S.; Loos, N.; Brenet-Dufour, V.; Liabeuf, S.; Bach, V.; Moretti, D.; Lewis, N.; Garenne, A.; Poulletier De Gannes, F.; Haro, E.; Lagroye, I.; Bornat, Y.; Boutaib, Y.; Saighi, S.; Renaud, S.; Veyre, B.; Schuz, J.; Deltour, I.; Van Deventer, E.; Vecchia, P.; Merckel, O.; Bellaouel, A.; Demaret, P.; Donati, P.; Jovanovic, D.; Chauvin, S.; Desreumaux, J.P.; Fouquet, L.; Picard, D.; Massardier-Pilonchery, A.; Hours, M.; Bergeret, A.; Person, C.; Toutain, Y.; Butet, R.; Berrahma, K.; Balderelli, I.; Stelmaszyk, V.; Cretallaz, C.; Lamproglou, I.; Amourette, C.; Diserbo, M.; Fauquette, W.; Martigne, P.; Collin, A.; Lagroye, I.; Ait Aissa, S.; Hurtier, A.; Taxile, M.; Le Montagner, L.; Athane, A.; Duleu, S.; Percherancier, Y.; Geffard, M.; Ruffie, G.; Billaudel, B.; Veyret, B.; Pelletier, A.; Delanaud, S.; Libert, J.P.; Schunck, T.; Bieth, F.; Soubere Mahamoud, Y.; Le Quement, C.; Ferrand, G.; Le Guevel, R.; Carton, P.H.; Luong, M.; Tanvir, S.; Selmaoui, B.; Silva Pires-Antonietti, V.; Sonnet, P.; Pulvin, S.; Kuster, O.; Tetelin, C.

    2012-04-01

    This document brings together the available presentations (articles and slides) given at the URSI scientific days on electromagnetic fields: dosimetry, peoples' exposure, biological and health risks, risk management, and medical uses. 48 presentations are compiled in this document and deal with: 1 - Stochastic dosimetry: variability challenge; 2 - How to estimate the exposure to 50/60 Hz magnetic field in an epidemiological study?; 3 - Joint analysis of population exposure and radio coverage of GSM and UMTS mobile phone networks; 4 - Study of the specific energy absorption rate (SAR) sensitiveness to phone positions near the head for 2 GSM mobile phones; 5 - Statistical Study of SAR under Wireless Channel - Exposure in Indoor Environment; 6 - Uncertainty propagation in numerical dosimetry: how to reduce calculation costs?; 7 - Use of a simplified pregnant woman model for foetus exposure analysis; 8 - SAR estimation using multi-exposure with a mobile phone; 9 - State-of-the-art in experimental dosimetry (RF and pulses); 10 - Mm-waves dosimetry: issues, stakes and actual solutions; 11 - Use of DG-FDTD for a dosimetry calculation in a strongly multi-scale problem: determination of the eye-SAR near a HF/VHF vehicle-borne source; 12 - Dosimetric measurements with a fiber-type electro-optical sensor; 13 - Partial experimental evaluation of basic restrictions in the HF/VHF range; 14 - Repetitive trans-cranial magnetic stimulation Stimulation (rTMS) in psychiatry: present day situation and perspectives; 15 - Medical applications of electric fields; 16 - Measurements for life: new perspectives? 17 - Nano-particles and magnetic stimuli for medical imaging and therapy; 18 - Molecular Insights into electroporation and siRNA electro-transfer through model cell membranes; 19 - State of knowledge on electromagnetic fields hypersensitivity (HS-CEM); 20 - Experimentation methodology: from results to interpretation; 22 - Mm waves - update on biological effects at 40-60 GHz; 23

  12. Comparison of calculations with neutron dosimetry measurements performed at the Oak Ridge Poolside Facility

    Energy Technology Data Exchange (ETDEWEB)

    Maerker, R.E.; Williams, M.L.

    1981-01-01

    The Oak Ridge Poolside Facility (PSF), like the Pool Critical Assembly (PCA), is used for benchmark dosimetry measurements which can serve to validate the transport methods used in calculating the high-energy neutron fluences (> 0.1 MeV) in LWR pressure vessels required to estimate the neutron damage to the pressure vessels in the form of embrittlement. The PSF consists of an arrangement of two water gaps of 4 and 12 cm thickness separated by a simulated thermal shield and followed by a simulated pressure vessel wall and then a void box to represent a reactor cavity. The PSF is driven by the 30 MW ORR reactor, whereas the geometrically similar core of the PCA has a maximum power of only 10 KW. This paper reports the results of some calculated activities and compares them with published PSF measurements performed by HEDL and other laboratories on the so-called Westinghouse surveillance capsule perturbation experiment.

  13. Comparison of calculations with neutron dosimetry measurements performed at the Oak Ridge Poolside Facility

    International Nuclear Information System (INIS)

    Maerker, R.E.; Williams, M.L.

    1981-01-01

    The Oak Ridge Poolside Facility (PSF), like the Pool Critical Assembly (PCA), is used for benchmark dosimetry measurements which can serve to validate the transport methods used in calculating the high-energy neutron fluences (> 0.1 MeV) in LWR pressure vessels required to estimate the neutron damage to the pressure vessels in the form of embrittlement. The PSF consists of an arrangement of two water gaps of 4 and 12 cm thickness separated by a simulated thermal shield and followed by a simulated pressure vessel wall and then a void box to represent a reactor cavity. The PSF is driven by the 30 MW ORR reactor, whereas the geometrically similar core of the PCA has a maximum power of only 10 KW. This paper reports the results of some calculated activities and compares them with published PSF measurements performed by HEDL and other laboratories on the so-called Westinghouse surveillance capsule perturbation experiment

  14. Apparatus to measure low level helium for neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Shuji; Takao, Yoshiyuki; Muramasu, Masatomo; Hida, Tomoya; Sou, Hirofumi; Nakashima, Hideki [Kyushu Univ., Fukuoka (Japan); Kanda, Yukinori

    1998-03-01

    An apparatus to measure low level helium in a solid sample for neutron dosimetry in the practical use such as area monitoring in the long-term and reactor surveillance was reported. In our previous work, the helium atoms measurement system (HAMS) was developed. A sample was evaporated in the furnace and the released gas from the sample was analyzed with the mass spectrometer of the system to determine the amount of helium contained in it. The system has been improved to advance the lower helium measurement limit in a solid sample for its application to an area monitoring system. The mass of a solid is up to 100mg. Two important points should be considered to advance the lower limit. One was to produce a high quality vacuum in the system chamber for suppressing background gases during the sample measurement. The other important point was to detect very small output from the mass spectrometer. A pulse counting system was used to get high sensitivity in the mass 4 analyzing. (author)

  15. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  16. Czech results at criticality dosimetry intercomparison 2002.

    Science.gov (United States)

    Frantisek, Spurný; Jaroslav, Trousil

    2004-01-01

    Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.

  17. Fast neutron dosimetry

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Pearson, D.W.

    1993-01-01

    Research concentrated on three major areas during the last twelve months: (1) investigations of energy fluence and absorbed dose measurements using crystalline and hot pressed TLD materials exposes to ultrasoft beams of photons, (2) fast neutron kerma factor measurements for several important elements as well as NE-213 scintillation material response function determinations at the intense ''white'' source available at the WNR facility at LAMPF, and (3) kerma factor ratio determinations for carbon and oxygen to A-150 tissue equivalent plastic at the clinical fast neutron radiation facility at Harper Hospital, Detroit, MI. Progress summary reports of these efforts are given in this report

  18. Internal exposure to neutron-activated {sup 56}Mn dioxide powder in Wistar rats. Pt. 1. Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Stepanenko, Valeriy; Kaprin, Andrey; Galkin, Vsevolod; Ivanov, Sergey; Kolyzhenkov, Timofey; Petukhov, Aleksey; Yaskova, Elena; Belukha, Irina; Khailov, Artem; Skvortsov, Valeriy; Ivannikov, Alexander; Akhmedova, Umukusum; Bogacheva, Viktoria [Medical Radiological Research Center (MRRC) named after A.F. Tsyb - National Medical Research Radiological Center of the Health Ministry of the Russian Federation, Obninsk, Kaluga Region (Russian Federation); Rakhypbekov, Tolebay; Dyussupov, Altay; Chaizhunusova, Nailya; Sayakenov, Nurlan; Uzbekov, Darkhan; Saimova, Aisulu; Shabdarbaeva, Dariya; Kairkhanova, Yankar [Semey State Medical University, Semey (Kazakhstan); Otani, Keiko; Endo, Satoru; Satoh, Kenichi; Kawano, Noriyuki; Fujimoto, Nariaki; Hoshi, Masaharu [Hiroshima University, Hiroshima (Japan); Shichijo, Kazuko; Nakashima, Masahiro; Takatsuji, Toshihiro [Nagasaki University, Nagasaki (Japan); Sakaguchi, Aya; Kato, Hiroaki; Onda, Yuichi [University of Tsukuba, Ibaraki (Japan); Toyoda, Shin [Okayama University of Science, Okayama (Japan); Sato, Hitoshi [Ibaraki Prefectural University of Health Science, Ibaraki (Japan); Skakov, Mazhin; Vurim, Alexandr; Gnyrya, Vyacheslav; Azimkhanov, Almas; Kolbayenkov, Alexander [National Nuclear Center of the Republic of Kazakhstan, Kurchatov (Kazakhstan); Zhumadilov, Kasym [Eurasian National University named after L.N. Gumilyov, Astana (Kazakhstan)

    2017-03-15

    There were two sources of ionizing irradiation after the atomic bombings of Hiroshima and Nagasaki: (1) initial gamma-neutron irradiation at the moment of detonation and (2) residual radioactivity. Residual radioactivity consisted of two components: radioactive fallout containing fission products, including radioactive fissile materials from nuclear device, and neutron-activated radioisotopes from materials on the ground. The dosimetry systems DS86 and DS02 were mainly devoted to the assessment of initial radiation exposure to neutrons and gamma rays, while only brief considerations were given for the estimation of doses caused by residual radiation exposure. Currently, estimation of internal exposure of atomic bomb survivors due to dispersed radioactivity and neutron-activated radioisotopes from materials on the ground is a matter of some interest, in Japan. The main neutron-activated radionuclides in soil dust were {sup 24}Na, {sup 28}Al, {sup 31}Si, {sup 32}P, {sup 38}Cl, {sup 42}K, {sup 45}Ca, {sup 46}Sc, {sup 56}Mn, {sup 59}Fe, {sup 60}Co, and {sup 134}Cs. The radionuclide {sup 56}Mn (T{sub 1/2} = 2.58 h) is known as one of the dominant beta- and gamma emitters during the first few hours after neutron irradiation of soil and other materials on ground, dispersed in the form of dust after a nuclear explosion in the atmosphere. To investigate the peculiarities of biological effects of internal exposure to {sup 56}Mn in comparison with external gamma irradiation, a dedicated experiment with Wistar rats exposed to neutron-activated {sup 56}Mn dioxide powder was performed recently by Shichijo and coworkers. The dosimetry required for this experiment is described here. Assessment of internal radiation doses was performed on the basis of measured {sup 56}Mn activity in the organs and tissues of the rats and of absorbed fractions of internal exposure to photons and electrons calculated with the MCNP-4C Monte Carlo using a mathematical rat phantom. The first results of

  19. Eleventh ORNL personnel dosimetry intercomparison study, May 22-23, 1985

    International Nuclear Information System (INIS)

    Swaja, R.E.; Oyan, R.; Sims, C.S.

    1986-07-01

    The Eleventh Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory (ORNL) during May 22-23, 1985. Dosimeter badges from 44 participating organizations were mounted on Lucite block phantoms and exposed to four mixed-radiation fields with neutron dose equivalents around 5 mSv and gamma dose equivalents between 0.1 and 0.7 mSv. Results of this study indicated that no participants had difficulty obtaining measurable indication of neutron exposure at the provided dose equivalent levels, and very few had difficulty obtaining indication of gamma exposure at dose equivalents as low as 0.10 mSv. Average neutron results for all dosimeter types were within 20% of reference values with no obvious spectrum dependence. Different dosimeter types (albedo, direct interaction TLD, film, recoil track, and combination albedo-track) with 10 or more reported measurements provided average results within 35% of reference values for all spectra. With regard to precision, about 80% of the reported neutron results had single standard deviations within 10% at the means which indicates that precision is not a problem relative to accuracy for most participants. Average gamma results were greater than reference values by factors of 1.07 to 1.52 for the four exposures with TLD systems being more accurate than film. About 80% of all neutron results and 67% of all gamma results met regulatory standards for measurement accuracy and approximately 70% of all neutron data satisfied national dosimetry accreditation criteria for accuracy plus precision. In general, neutron dosimeter performance observed in this intercomparison was much improved compared to that observed in the prior studies while gamma dosimeter performance was about the same

  20. Neutron measurements at nuclear power reactors [55

    CERN Document Server

    Scherpelz, R I

    2002-01-01

    Staff from the Pacific Northwest National Laboratory (operated by Battelle Memorial Institute), have performed neutron measurements at a number of commercial nuclear power plants in the United States. Neutron radiation fields at light water reactor (LWR) power plants are typically characterized by low-energy distributions due to the presence of large amounts of scattering material such as water and concrete. These low-energy distributions make it difficult to accurately monitor personnel exposures, since most survey meters and dosimeters are calibrated to higher-energy fields such as those produced by bare or D sub 2 O-moderated sup 2 sup 5 sup 2 Cf sources. Commercial plants typically use thermoluminescent dosimeters in an albedo configuration for personnel dosimetry and survey meters based on a thermal-neutron detector inside a cylindrical or spherical moderator for dose rate assessment, so their methods of routine monitoring are highly dependent on the energy of the neutron fields. Battelle has participate...

  1. 100 years of solid state dosimetry and radiation protection dosimetry

    International Nuclear Information System (INIS)

    Bartlett, David T.

    2008-01-01

    The use of solid state detectors in radiation dosimetry has passed its 100th anniversary. The major applications of these detectors in radiation dosimetry have been in personal dosimetry, retrospective dosimetry, dating, medical dosimetry, the characterization of radiation fields, and also in microdosimetry and radiobiology research. In this introductory paper for the 15th International Conference, I shall speak of the history of solid state dosimetry and of the radiation measurement quantities that developed at the same time, mention some landmark developments in detectors and applications, speak a bit more about dosimetry and measurement quantities, and briefly look at the past and future

  2. Accuracy of helium accumulation fluence monitor for fast reactor dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Chikara; Aoyama, Takafumi [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-03-01

    A helium (He) accumulation fluence monitor (HAFM) has been developed for fast reactor dosimetry. In order to evaluate the measurement accuracy of neutron fluence by the HAFM method, the HAFMs of enriched boron (B) and beryllium (Be) were irradiated in the Fast Neutron Source Reactor `YAYOI`. The number of He atoms produced in the HAFMs were measured and compared with the calculated values. As a result of this study, it was confirmed that the neutron fluence could be measured within 5 % by the HAFM method, and that met the required accuracy for fast reactor dosimetry. (author)

  3. Introduction to radiological physics and radiation dosimetry

    CERN Document Server

    Attix, Frank Herbert

    2004-01-01

    A straightforward presentation of the broad concepts underlying radiological physics and radiation dosimetry for the graduate-level student. Covers photon and neutron attenuation, radiation and charged particle equilibrium, interactions of photons and charged particles with matter, radiotherapy dosimetry, as well as photographic, calorimetric, chemical, and thermoluminescence dosimetry. Includes many new derivations, such as Kramers X-ray spectrum, as well as topics that have not been thoroughly analyzed in other texts, such as broad-beam attenuation and geometrics, and the reciprocity theorem

  4. Experimentals on the energy-deposition of fast neutrons in phantoms

    International Nuclear Information System (INIS)

    Maier, E.

    1978-01-01

    The relative neutron sensitivities of a tissue-equivalent chamber and a carbon chamber with correction factors are given for four neutron energies and a 252 Cf-source. The necessary experimental and technical conditions for an application of the multi-detector mixed-field dosimetry with proportional counters are presented. The corrections accounting for charge recombination or the intensity decrease due to the chamber well are put on a theoretical basis. (DG) [de

  5. Method and apparatus for producing ultralowmass fissionable deposits for reactor neutron dosimetry by recoil ion-implantation

    International Nuclear Information System (INIS)

    Ruddy, F.H.

    1988-01-01

    A method for producing a fissionable deposit of selectively ultralow mass for neutron dosimetry is described comprising the steps of: (a) spacing in opposing relation a substrate and an alpha-emitting parent source which decays to implant into the substrate of fissionable daughter ejected from the parent source as a result of the decay; and (b) holding the opposing relation for a period of time until the parent source decays to form a corresponding mass of isotopically pure fissionable daughter uniformly on the substrate

  6. Passive detectors for neutron fluence measurement

    International Nuclear Information System (INIS)

    Holt, P.D.

    1985-01-01

    The use of neutron activation detectors (slow neutron detectors and threshold detectors) and fission track detectors for radiological protection purposes, principally in criticality dosimetry, dosimetry of pulsed accelerators and calibration of neutron fluxes is discussed. References are given to compilations of cross sections. For the determination of the activity induced, either beta ray or gamma ray counting may be used. For beta-ray counting, thin foils are usually necessary which result in low neutron sensitivity. When fission track detectors are used, it is necessary to know the efficiency of track registration. Alternatively, a detector-counter system may be calibrated by exposure to a known flux of monoenergetic neutrons. Usually, the sensitivity of activation detectors is low because small foils are used. For criticality dosimetry, calibration work and shielding studies on accelerators, low sensitivity is acceptable. However, there are some instances where, by the use of long integration times, or very large quantities of detector material with gamma ray detection, neutron fluences in operational areas have been measured. (author)

  7. Trends of personal dosimetry at atomic power plants

    International Nuclear Information System (INIS)

    Yamamura, Seini

    1998-01-01

    The individual dosimetry at the atomic power station is sorted for monthly dosimetry, daily dosimetry and special job dosimetry in high dose circumstance. Film badge (passive dosimeter) can measure gamma dose, beta dose and neutron dose respectively lower than about 0.1 mSv. While workers are in the radiation controlled area, they have to wear the dosimeters and the individual dose is accumulated for every one month. Recently the Silicon semiconductors detecting beta ray and neutron have been developed. With microcircuit technology and these new sensors, new multiple function dosimeter of the card size had been put to practical use. The result of dose measurement obtained by the electronic dosimeter is consistent well with the measurement of usual film badge and new dosimeter can determine the dose as low as 0.01 mSv. The result is stored in the non-volatile memory in the electronic personal dosimeter and held for more than one year without the power supply. The function to read data directly from the memory improves the reliability of the data protection. The realization of the unified radiation control system that uses the electronic personal dosimeter for monthly dosimetry is expected. (J.P.N.)

  8. Summary report of the technical meeting on 'International Reactor Dosimetry File: IRDF-2002'

    International Nuclear Information System (INIS)

    Greenwood, L.R.; Paviotti-Corcuera, R.

    2002-09-01

    This report summarizes the presentations, recommendations and conclusions of the Technical Meeting on 'International Reactor Dosimetry File: IRDF-2002.' The purpose of this meeting was to discuss scientific and technical matters related to the subject and coordinate related tasks. Discussions were held and recommendations were given for the preparation of the files on topics related to: reactions to be included, need for new evaluations or revisions, decay data, radiation damage data, integral testing in benchmark fields, and computer codes to be included. Tasks were assigned and deadlines were set. The participants emphasized that accurate and complete knowledge of nuclear data for reactor dosimetry are essential for improving the accuracy of the reactor pressure vessel service life assessment of nuclear power plants as well as in other neutron metrology applications such as boron neutron capture therapy, therapeutic use of medical isotopes, nuclear physics measurements, and reactor safety applications. (author)

  9. Hair {sup 32}P measurement for body dose mapping in non-fatal exposures to fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Mianji, Fereidoun A. [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Jafari, Sheyda; Zaryouni, Saiedeh [Bu-Ali Sina University, Faculty of Science, Hamedan (Iran, Islamic Republic of); Hajizadeh, Bardia [Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of)

    2015-03-15

    Dosimetry bioassay methods are the backbone of a personal dosimetry in criticality accidents. Although methods like hair dosimetry and the use of activation foils (e.g., {sup 32}S) have been employed for decades, capabilities of different techniques, effects of hair type and neutron spectrum on the dose response, sensitivity and uncertainties of different techniques, etc., need more investigations. For this reason, the use of the {sup 32}S(n,p){sup 32}P reaction and hair samples for estimating non-fatal doses from fast neutrons was studied. The experiments were carried out with the hair samples attached on a RANDO phantom in a Cf-252 neutron field, in the dose range of about 0.05-1.15 Gy. In addition, the adequate post-accident preparation for hair samples including optimum conditioning and timing were investigated. Experimental results prove the good sensitivity and merit of the method for neutron quantification in the mentioned dose range for which other bioassay methods are of poor resolution and sensitivity. A rough estimation of the dose-response curve for Iranian hair was also derived. (orig.)

  10. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    This paper summarizes the applications of ASTM standard methods, guides and practices to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and development of advanced dosimetry sets for commercial reactors is also summarized. (Auth.)

  11. Neutron stars velocities and magnetic fields

    Science.gov (United States)

    Paret, Daryel Manreza; Martinez, A. Perez; Ayala, Alejandro.; Piccinelli, G.; Sanchez, A.

    2018-01-01

    We study a model that explain neutron stars velocities due to the anisotropic emission of neutrinos. Strong magnetic fields present in neutron stars are the source of the anisotropy in the system. To compute the velocity of the neutron star we model its core as composed by strange quark matter and analice the properties of a magnetized quark gas at finite temperature and density. Specifically we have obtained the electron polarization and the specific heat of magnetized fermions as a functions of the temperature, chemical potential and magnetic field which allow us to study the velocity of the neutron star as a function of these parameters.

  12. Radiological Protection Dosimetry Section report of work done and list of publications during 1981-1982

    International Nuclear Information System (INIS)

    Krishnan, D.; Venkataraman, G.

    1983-01-01

    Radiological Protection Dosimetry Section has as its objective development of dosimetric techniques, theoretical as well as experimental. To this end in view, research and development work on chemical and neutron dosimetry systems, computational dosimetry and dosimetry associated with protection problems is being done. Work is also carried out on radiobiological investigations at cellular level to understand radiation damage and interpret the basis of radiation exposure limits and attendant safety standards. These topics are covered by five groups in the section viz. Neutron Dosimetry, Chemical Dosimetry, Radiation Biophysics, Radium Hazards Evaluation and Control, and Theoretical studies. A brief outline of the activities of each of the above groups is given along with a list of publications for the last two years. (author)

  13. Reference dosimetry and small-field dosimetry in external beam radiotherapy: Results from a Danish intercomparison study

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, Claus F.; Sibolt, Patrik

    methods was performed by DTU Nutech at six Danish clinics. The first part of the intercompa-rison regarded the consistency of reference dosimetry. Absorbed dose to water under reference conditions was measured using a Farmer ionization chamber, and was found to agree within 1 % with the daily dose checks......-specific correction factors for non-reference fields....

  14. Neutron spectrum survey around the cyclotron of IEN/Brazilian CNEN: calibration of neutron personnel dosemeter

    International Nuclear Information System (INIS)

    Fajardo, P.W.

    1991-01-01

    The albedo neutron dosimeter is calibrated directly at the work place due to its high energy dependence. This thesis deals with the study, analysis and application of neutron measurement techniques in order to obtain information about the neutron spectrum and neutron dose equivalent at several representative working places of the cyclotron laboratory of the Nuclear Engineering Institute (IEN). These data are employed mainly in the calibration of the brazilian albedo neutron dosimeter. Bonner spheres and foil activation were used in neutron spectra measurements and the neutron dose equivalents were measured with the single sphere albedo technique. BF 3 and 3 He proportional detectors and 6 LiI scintillation detector were also used in these measurements. The single sphere technique turned out to be more appropriate for neutron dosimetry for calibrating the albedo dosimeter in the varying fields of the cyclotron. Calibration the albedo dosimeter in the varying fields of the cyclotron. Calibration factors were found for routine applications, when the workers are protected by shielding and for radiological accident applications, in the case that a worker is exposed inside the cyclotron room. In all situations the performance of the brazilian albedo dosimeter is compared with that of the german albedo dosimeters. (author)

  15. EURADOS intercomparison 2012 for neutron dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Fantuzzi, E. [ENEA-Radiation Protection Institute, Bologna (Italy); Chevallier, M.A. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France); Cruz-Suarez, R. [International Atomic Energy Agency, Vienna (Austria); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Mayer, S. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Thomas, D.J. [National Physical Laboratory (NPL), Teddington (United Kingdom); Tanner, R. [Public Health England, Oxon (United Kingdom); Vanhavere, F. [SCK-CEN, Belgian Nuclear Research Centre, Mol (Belgium)

    2014-11-15

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ({sup 252}Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ({sup 252}Cf at 45 ) or for simulated workplace fields ({sup 252}Cf(D{sub 2}O) or {sup 252}Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection

  16. Dosimetry considerations in the head and retina for extremely low frequency electric fields

    International Nuclear Information System (INIS)

    Taki, M.; Suzuki, Y.; Wake, K.

    2003-01-01

    Magnetophosphenes are investigated from the viewpoint of electromagnetic dosimetry. Induced current density and internal electric fields at the threshold of perception are estimated by analytical and numerical calculations, assuming different models. Dosimetry for electrophoshenes is also discussed and compared with that for magnetophosphenes. The distribution of current density and internal electric fields is consistent with the experimental observation that flashing sensations reach their greatest intensity at the periphery of the visual field, for both electro and magnetophosphenes. The estimated thresholds in internal electric fields are consistent for magnetophosphenes and for electrophosphenes, respectively. The magnitudes of the thresholds, however, differ by about 10-fold. The thresholds in induced current density are critically dependent on the conductivity of the eye assumed for the calculations. The effect of thin membrane structure is also discussed with regard to the difference between electric field and magnetic field exposures. (author)

  17. Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-01

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, {gamma}) process in Na{sup 23}, giving rise to Na{sup 24}, which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na{sup 24}, is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na{sup 23} in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na{sup 24}/Na{sup 23} in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R{sub B} reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzman transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given. A summary of the 4{pi

  18. Neutron stars, magnetic fields, and gravitational waves

    International Nuclear Information System (INIS)

    Lamb, F.K.

    2001-01-01

    The r-modes of rapidly spinning young neutron stars have recently attracted attention as a promising source of detectable gravitational radiation. These neutron stars are expected to have magnetic fields ∼ 10 12 G. The r-mode velocity perturbation causes differential motion of the fluid in the star; this is a kinematic effect. In addition, the radiation-reaction associated with emission of gravitational radiation by r-waves drives additional differential fluid motions; this is a dynamic effect. These differential fluid motions distort the magnetic fields of neutron stars and may therefore play an important role in determining the structure of neutron star magnetic fields. If the stellar field is ∼ 10 16 (Ω/Ω B ) G or stronger, the usual r-modes are no longer normal modes of the star; here Ω and Ω B are the angular velocities of the star and at which mass shedding occurs. Much weaker magnetic fields can prevent gravitational radiation from amplifying the r-modes or damp existing r-mode oscillations on a relatively short timescale by extracting energy from the modes faster than gravitational wave emission can pump energy into them. The onset of proton superconductivity in the cores of newly formed magnetic neutron stars typically increases the effect on the r-modes of the magnetic field in the core by many orders of magnitude. Once the core has become superconducting, magnetic fields of the order of 10 12 G or greater are usually sufficient to damp r-modes that have been excited by emission of gravitational radiation and to suppress any further emission. A rapid drop in the strength of r-mode gravitational radiation from young neutron stars may therefore signal the onset of superconductivity in the core and provide a lower bound on the strength of the magnetic field there. Hence, measurements of r-mode gravitational waves from newly formed neutron stars may provide valuable diagnostic information about magnetic field strengths, cooling processes, and the

  19. Testing of the IRDF-90 cross-section library in benchmark neutron spectra

    International Nuclear Information System (INIS)

    Nolthenius, H.J.; Zsolnay, E.M.; Szondi, E.J.

    1993-09-01

    The new version of the International Reactor Dosimetry File IRDF-90 (called ''Version April 1993'') has been tested by calculation of average cross-sections and their uncertainties in a coarse three energy group structure and by neutron spectrum adjustments in reference neutron spectra. This paper presents the results obtained and compares them with the corresponding ones of the old IRDF-85 and with the data of the Nuclear Data Guide for Reactor Neutron Metrology. The applicability of the new library in the field of neutron metrology is discussed. (orig.)

  20. Further developments and applications of layer gel dosimetry

    International Nuclear Information System (INIS)

    Gambarini, G; Carrara, M; Colli, V; Gay, S; Tomatis, S

    2004-01-01

    The method used to perform dosimetry with Fricke-xylenol orange-infused gels in form of layers remains the most reliable method for in-phantom dose profiling and imaging in high fluxes of thermal and epithermal neutrons. Gel-dosimeters in form of layers really give the possibility not only of obtaining spatial dose distributions but also of achieving measurements of each dose contribution in neutron fields. These advantages arise from the layer-geometry thanks to which neutron transport is not sensibly altered, even if the elemental gel composition is changed adding particular isotopes (for example 10 B), as necessary to perform the separation of dose contributions. The gel matrix composition and the experimental procedures, adopted for both dosimeter preparation and analysis, have been already described in previous works. In the present work, the improvements of the method employed for gel analysis, dose imaging and gel applications are illustrated

  1. Calorimetric dosimetry in neutron and charged particle beams

    International Nuclear Information System (INIS)

    McDonald, J.C.; Ma, I.C.; Laughlin, J.S.

    1978-01-01

    A portable tissue-equivalent (TE) calorimetric, constructed of A-150 plastic, has been employed for the measurement of absorbed dose in several neutron radiotherapy fields. Comparisons of spherical, cylindrical, and thimble shaped TE ionization chambers have been carried out using either air, or a flow of TE gas in the chamber

  2. Group: radiation dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.

    1990-01-01

    The main activities of the radiation dosimetry group is described, including the calibration of instruments, sources and radioactive solutions and the determination of neutron flux; development, production and market dosimetric materials; development radiation sensor make the control of radiation dose received by IPEN workers; development new techniques for monitoring, etc. (C.G.C.)

  3. Prompt gamma-based neutron dosimetry for Am-Be and other workplace neutron spectra

    International Nuclear Information System (INIS)

    Udupi, Ashwini; Panikkath, Priyada; Sarkar, P.K.

    2016-01-01

    A new field-deployable technique for estimating the neutron ambient dose equivalent H*(10) by using the measured prompt gamma intensities emitted from borated high-density polyethylene (BHDPE) and the combination of normal HDPE and BHDPE with different configurations have been evaluated in this work. Monte Carlo simulations using the FLUKA code has been employed to calculate the responses from the prompt gammas emitted due to the monoenergetic neutrons interacting with boron, hydrogen, and carbon nuclei. A suitable linear combination of these prompt gamma responses (dose conversion coefficient (DCC)-estimated) is generated to approximate the International Commission on Radiological Protection provided DCC using the cross-entropy minimization technique. In addition, the shape and configurations of the HDPE and BHDPE combined system are optimized using the FLUKA code simulation results. The proposed method is validated experimentally, as well as theoretically, using different workplace neutron spectra with a satisfactory outcome. (author)

  4. Revue of some dosimetry and dose assessment European projects

    International Nuclear Information System (INIS)

    Bolognese-Milsztajn, T.; Frank, D.; Lacoste, V.; Pihet, P.

    2006-01-01

    Full text of publication follows: Within the 5. Framework Programme of the European Commission several project dealing with dosimetry and dose assessment for internal and external exposure have been supported. A revue of the results of some of them is presented in this paper. The EURADOS network which involved 50 dosimetry institutes in EUROPE has coordinated the project DOSIMETRY NETWORK: the main results achieved within this action are the following: - The release on the World Wide Web of the EURADOS Database of Dosimetry Research Facilities; - The realisation of the report 'Harmonization of Individual Monitoring (IM) in Europe'; - The continuation of the intercomparisons programme of environmental radiation monitoring systems; - The realisation of the report Cosmic radiation exposure of aircraft crew. The EVIDOS project aimed at evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry with complex mixed neutron-photon radiation fields. This paper summarises the main findings from a practical point of view. Conclusions and recommendations will be given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosimeters results. The IDEA project aimed to improve the assessment of incorporated radionuclides through developments of advanced in-vivo and bioassay monitoring techniques and making use of such enhancements for improvements in routine monitoring. The primary goal was to categorize those new developments regarding their potential and eligibility for the routine monitoring community. The costs of monitoring for internal exposures in the workplace are usually significantly greater than the equivalent costs for external exposures. There is therefore a need to ensure that resources are employed with maximum effectiveness. The EC-funded OMINEX (Optimisation of Monitoring for Internal Exposure) project has developed methods for optimising the design and implementation of

  5. Dosimetry measurements for a criticality exercise based on moderated 2.5 MeV accelerator neutrons

    International Nuclear Information System (INIS)

    Delafield, H.J.; Harrison, K.G.; Harvey, J.R.; Hudd, W.H.R.

    1979-02-01

    A joint criticality exercise between BNL and Harwell was held on 22 March 1978 to test criticality dosimetry procedures, and to establish an irradiation technique which could be used to simulate the irradiation of criticality dosimeters in a criticality excursion. Dosimeters were irradiated on a phantom by moderated 2.5 MeV accelerator neutrons using facilities at BNL, and then transported rapidly to Harwell for assessment. This exercise showed that despite the limited dose rate available from the accelerator, such an irradiation could be used successfully to simulate a criticality incident. The induced dosimeter activities were adequate for the initial monitoring at BNL and a subsequent full dose assessment at Harwell. Neutron dose assessments obtained by different methods of interpretation were both self-consistent (1.7 +- 0.2 rad), and in good agreement with an independent estimate of dose (2.0 +- 1.0 rad) based on measurements made with a De Pangher Long counter at BNL. (author)

  6. A Neutron Radiography System for Field Use

    Science.gov (United States)

    1989-06-01

    provoked a major renewal of interest in neutron radiography because it promises to bring neutron radiography to the workplace , a convenience provided...II I~F I C II i IiH i ii MTL TR 89-52 I-AD A NEUTRON RADIOGRAPHY SYSTEM N FOR FIELD USE e~m JOHN J. ANTAL and ALFRED S. MAROTTA, and LOUIS J. FARESE...COVERED A NEUTRON RADIOGRAPHY SYSTEM FOR FIELD USE Final Report 6. PERFORMING OR1. REPORT NUMBER 7. AUTHOR(s) S. CONTRACT OR GRANT NUMBER(s) John J

  7. Survey of international personnel radiation dosimetry programs

    International Nuclear Information System (INIS)

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables

  8. A comparison of the BUGLE-80, SAILOR, and ELXSIR neutron cross-section libraries for PWR pressure vessels surveillance dosimetry and shielding applications

    International Nuclear Information System (INIS)

    Basha, H.S.; Manahan, M.P.

    1992-01-01

    In this paper three multigroup neutron cross-section libraries are used in synthesized three-dimensional discrete ordinates transport analyses to investigate their similarities, differences, and results for pressurized water reactor (PWR) pressure vessel surveillance dosimetry and shielding applications. The calculated-to-experimental (C/E) rations and the calculated reaction rates of several fast reactions are compared for the BUGLE-80, SAILOR, and ELXSIR cross-section libraries at the 97-deg surveillance capsule of the San Onofre Nuclear Generation Station Unit 2 (SONGS-2) and at the 90- and 97-deg (C/E ratios only) cavity dosimetry locations for another PWR (referred to as Reactor X)

  9. Measurement of the neutron fields produced by a 62 MeV proton beam on a PMMA phantom using extended range Bonner sphere spectrometers

    International Nuclear Information System (INIS)

    Amgarou, K.; Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; Carinci, G.; Russo, S.

    2011-01-01

    The experimental characterization of the neutron fields produced as parasitic effect in medical accelerators is assuming an increased importance for either the patient protection or the facility design aspects. Medical accelerators are diverse in terms of particle type (electrons or hadrons) and energy, but the radiation fields around them have in common (provided that a given threshold energy is reached) the presence of neutrons with energy span over several orders of magnitude. Due to the large variability of neutron energy, field or dosimetry measurements in these workplaces are very complex, and in general, cannot be performed with ready-to-use commercial instruments. In spite of its poor energy resolution, the Bonner Sphere Spectrometer (BSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. The energy range of this instrument is limited to E o and 90 o with respect to the beam-line. Here the ERBSS of UAB (Universidad Autonoma de Barcelona-Grup de Fisica de les Radiacions) and INFN (Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Frascati) were exposed to characterize the 'forward' and 'sideward' proton-induced neutron fields. The use of two ERBSS characterized by different set of spheres, central detectors, and independently established and calibrated, is important for guaranteeing the robustness of the measured spectra and estimating their overall uncertainties.

  10. Characteristics of thermal neutron calibration fields using a graphite pile

    International Nuclear Information System (INIS)

    Uchita, Yoshiaki; Saegusa, Jun; Kajimoto, Yoichi; Tanimura, Yoshihiko; Shimizu, Shigeru; Yoshizawa, Michio

    2005-03-01

    The Facility of Radiation Standards of Japan Atomic Energy Research Institute is equipped with thermal neutron fields for calibrating area and personal neutron dosemeters. The fields use moderated neutrons leaked from a graphite pile in which radionuclide sources are placed. In January 2003, we have renewed the pile with some modifications in its size. In accordance with the renewal, we measured and calculated thermal neutron fluence rates, neutron energy distributions and angular distributions of the fields. The thermal neutron fluence rates of the ''inside-pile fields'' and the outside-pile fields'' were determined by the gold foil activation method. The neutron energy distributions of the outside-pile fields were also measured with the Bonner multi-sphere spectrometer system. The contributions of epithermal and fast neutrons to the total dose-equivalents were 9% in the southern outside-pile field and 12% in the western outside-pile field. The personal dose-equivalents, H p,slab (10, α), in the outside-pile fields are evaluated by considering the calculated angular distributions of incoming neutrons. The H p,slab (10, α) was found to be about 40% higher than the value in assuming the unidirectional neutron between the pile and the test point. (author)

  11. Radiation resistance of elastomeric O-rings in mixed neutron and gamma fields: Testing methodology and experimental results

    Science.gov (United States)

    Zenoni, A.; Bignotti, F.; Donzella, A.; Donzella, G.; Ferrari, M.; Pandini, S.; Andrighetto, A.; Ballan, M.; Corradetti, S.; Manzolaro, M.; Monetti, A.; Rossignoli, M.; Scarpa, D.; Alloni, D.; Prata, M.; Salvini, A.; Zelaschi, F.

    2017-11-01

    Materials and components employed in the presence of intense neutron and gamma fields are expected to absorb high dose levels that may induce deep modifications of their physical and mechanical properties, possibly causing loss of their function. A protocol for irradiating elastomeric materials in reactor mixed neutron and gamma fields and for testing the evolution of their main mechanical and physical properties with absorbed dose has been developed. Four elastomeric compounds used for vacuum O-rings, one fluoroelastomer polymer (FPM) based and three ethylene propylene diene monomer rubber (EPDM) based, presently available on the market have been selected for the test. One EPDM is rated as radiation resistant in gamma fields, while the other elastomers are general purpose products. Particular care has been devoted to dosimetry calculations, since absorbed dose in neutron fields, unlike pure gamma fields, is strongly dependent on the material composition and, in particular, on the hydrogen content. The products have been tested up to about 2 MGy absorbed dose. The FPM based elastomer, in spite of its lower dose absorption in fast neutron fields, features the largest variations of properties, with a dramatic increase in stiffness and brittleness. Out of the three EPDM based compounds, one shows large and rapid changes in the main mechanical properties, whereas the other two feature more stable behaviors. The performance of the EPDM rated as radiation resistant in pure gamma fields does not appear significantly better than that of the standard product. The predictive capability of the accelerated irradiation tests performed as well as the applicable concepts of threshold of radiation damage is discussed in view of the use of the examined products in the selective production of exotic species facility, now under construction at the Legnaro National Laboratories of the Italian Istituto Nazionale di Fisica Nucleare. It results that a careful account of dose rate effects

  12. Environmental dosimetry

    International Nuclear Information System (INIS)

    Gold, R.

    1977-01-01

    For more than 60 years, natural radiation has offered broad opportunities for basic research as evidenced by many fundamental discoveries. Within the last decade, however, dramatic changes have occurred in the motivation and direction of this research. The urgent need for economical energy sources entailing acceptably low levels of environmental impact has compelled the applied aspects of our radiation environment to become overriding considerations. It is within this general framework that state-of-the-art environmental dosimetry techniques are reviewed. Although applied motivation and relevance underscores the current milieu for both reactor and environmental dosimetry, a perhaps even more unifying force is the broad similarity of reactor and environmental radiation fields. In this review, a comparison of these two mixed radiation fields is presented stressing the underlying similarities that exist. On this basis, the evolution of a strong inner bond between dosimetry methods for both reactor and environmental radiation fields is described. The existence of this bond will be illustrated using representative examples of observed spectra. Dosimetry methods of particularly high applicability for both of these fields are described. Special emphasis is placed on techniques of high sensitivity and absolute accuracy which are capable of resolving the components of these mixed radiation fields

  13. Calculation of Multisphere Neutron Spectrometer Response Functions in Energy Range up to 20 MeV

    CERN Document Server

    Martinkovic, J

    2005-01-01

    Multisphere neutron spectrometer is a basic instrument of neutron measurements in the scattered radiation field at charged-particles accelerators for radiation protection and dosimetry purposes. The precise calculation of the spectrometer response functions is a necessary condition of the propriety of neutron spectra unfolding. The results of the response functions calculation for the JINR spectrometer with LiI(Eu) detector (a set of 6 homogeneous and 1 heterogeneous moderators, "bare" detector within cadmium cover and without it) at two geometries of the spectrometer irradiation - in uniform monodirectional and uniform isotropic neutron fields - are given. The calculation was carried out by the code MCNP in the neutron energy range 10$^{-8}$-20 MeV.

  14. Compilation of neutron flux density spectra and reaction rates in different neutron fields

    International Nuclear Information System (INIS)

    Ertek, C.

    1979-07-01

    Upon the recommendation of International Working Group of Reactor Radiation Measurements (IWGRRM), the compilation of neutron flux density spectra and the reaction rates obtained by activation and fission foils in different neutron fields is presented. The neutron fields considered are as follows: 1/E; iron block; LWR core and pressure vessel; LMFBR core and blanket; CTR first wall and blanket; fission spectrum

  15. Small Field Dosimetry Comparing Measured Data Versus the ADAC Pinnacle 3 Model

    National Research Council Canada - National Science Library

    Ludolph, Daniel

    2004-01-01

    .... While this method can optimize conformity to tumors and provide better sparing of surrounding tissue, it also presents a host of challenges due to reliance on dosimetry data for small field sizes...

  16. Intercomparison measurements with albedo neutron dosimeters

    International Nuclear Information System (INIS)

    Alberts, W.G.; Kluge, H.

    1994-01-01

    Since the introduction of the albedo dosimeter as the official personal neutron dosimeter the dosimetry services concerned have participated in intercomparison measurements at the PTB. Their albedo dosimeters were irradiated in reference fields produced by unmoderated and D 2 O-moderated 252 Cf neutron sources in the standard irradiation facility of the PTB. Six fields with fluences different in energy and angle distribution could be realised in order to determine the response of the albedo dosimeter. The dose equivalent values evaluated by the services were compared with the reference values of the PTB for the directional dose equivalent H'(10). The results turned out to be essentially dependent on the evaluation method and the choice of the calibration factors. (orig.) [de

  17. Certification of an iron metal reference material for neutron dosimetry (EC nuclear reference material 524)

    International Nuclear Information System (INIS)

    Ingelbrecht, C.; Pauwels, J.; Lievens, F.

    1993-01-01

    Iron metal, of > 99.996% nominal purity, in the form of 0.1 mm thick foil and of 0.5 mm diameter wire has been certified for its manganese and cobalt mass fractions. The certified value of the cobalt mass fraction ( -1 ) is based on 39 accepted results from five laboratories using two different methods. The certified value of the manganese mass fraction ( -1 ) is based on 41 accepted results from five laboratories using three different methods. The overall purity was also verified. The material is intended to be used as a reference material in neutron dosimetry. (authors). 8 refs., 9 tabs., 2 figs

  18. Development of neutron calibration field using accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Mamoru [Tohoku Univ., Cyclotron and Radioisotope Center, Sendai, Miyagi (Japan)

    2003-03-01

    A brief summary is given on the fast neutron calibration fields for 1) 8 keV to 15 MeV range, and 2) 30-80 MeV range. The field for 8 keV to 15 MeV range was developed at the Fast Neutron Laboratory (FNL) at Tohoku University using a 4.5 MV pulsed Dynamitron accelerator and neutron production reactions, {sup 45}Sc(p, n), {sup 7}Li(p, n), {sup 3}H(p, n), D(d, n) and T(d, n). The latter 30-80 MeV fields are setup at TIARA of Takasaki Establishment of Japan Atomic Energy Research Institute, and at Cyclotron Radio Isotope Center (CYRIC) of Tohoku University using a 90 MeV AVF cyclotron and the {sup 7}Li(p, n) reaction. These fields have been applied for various calibration of neutron spectrometers and dosimeters, and for irradiation purposes. (author)

  19. Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Maldonado-Velázquez, M. [Posgrado en Ciencias Físicas, Universidad Nacional Autónoma de México, 04510 (Mexico); Barrón-Palos, L., E-mail: libertad@fisica.unam.mx [Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, 01000 (Mexico); Crawford, C. [University of Kentucky, Lexington, KY 40506 (United States); Snow, W.M. [Indiana University, Bloomington, IN 47405 (United States)

    2017-05-11

    The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10{sup −7} rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

  20. Evaluation of the neutrons spectrum near the Venus reactor: use of MCNPX-2.5C

    International Nuclear Information System (INIS)

    Verboomen, B.; Coeck, M.; Baeten, P.

    2003-01-01

    The present study has been justified by the choice of the Venus reactor (SCK-CEN) as a true work environment for the project of the fifth programme - frame E.V.I.D.O.S.. The objective of this programme is the evaluation, in neutron-photon combined field, and in true environment (nuclear industry), of the different methods of measurement used in neutron dosimetry. The project aims to the determination of abilities and limits of dosemeters and to establish methods to get doses equivalents from data gotten by spectrometry, personal and ambient dosimetry. For each environment, reference values have to be determined by spectrometry (energy and angle). The knowledge of the distribution in energy and in angle of neutrons allows then the calculation of the different doses equivalents. The determination of these references values by direct neutron calculation allows the validation of the Monte Carlo model. (N.C.)

  1. Dosimetry Characteristics of Coupled Fast-Thermal Core 'HERBE'

    International Nuclear Information System (INIS)

    Pesic, M.; Milosevic, M.; Milovanovic, S.

    1996-01-01

    The 'HERBE' is new coupled fast-thermal core, designed in 1991, at the 'RB' reactor in the 'Vinca' Institute. It is used for verification of designed oriented computer codes developed in the Institute, training and sample irradiation in fast neutron field. For the last purpose a vertical experimental channel (VCH) is placed in the central axis of the fast core. Neutron spectrum in the centre of the VCR is calculated in 44 energy groups. Space distributions of two energy group neutron flux in the 'HERBE' are measured using gold foils and converted into the neutron absorbed dose (in air and tissue) using group flux-dose conversion factors. Gamma absorption doses in the air in the centre of the VCH are measured using calibrated small ionisation chamber filled with air. Determined dose rates are related to the reactor power. The first preliminary irradiations of silicon diodes (designed for production of the neutron dosemeters) in the centre of the VCH of the 'HERBE' fast core are carried out in 1994 and 1995. This paper describes calculation methods and measurement techniques applied to determination of the irradiation performance and dosimetry characteristics of the 'HERBE' system. (author)

  2. CERN’s neutrons fly higher

    CERN Multimedia

    Antonella Del Rosso

    2012-01-01

    The construction of a second experimental area for n_TOF – CERN’s neutron source – has just been approved by the CERN Council. The new facility will provide the scientific community with a higher neutron flux, which translates into a higher sensitivity for the experiments. The new neutron beam line will open the way to a wider variety of research fields including nuclear energy applications, nuclear astrophysics, basic nuclear physics, dosimetry and radiation damage.   The 4π calorimeter inside the n_TOF experimental area. Image courtesy of the n_TOF Collaboration. The project involves building a vertical flight path roughly 20 m above the current neutron target and a new experimental hall – Experimental Area 2 (EAR-2) – in the current Building 559. EAR-2 will be located on top of the neutron production target and partially on top of the ISR building (see the image below of a model of the facility). “The hall will be housed i...

  3. Dosimetry, instrumentation and exposure chambers for dc magnetic field studies

    International Nuclear Information System (INIS)

    Tenforde, T.S.

    1979-03-01

    The principal objective of this report is to describe in detail an exposure chamber that was developed at the Lawrence Berkeley Laboratory for automated, noninvasive studies of rodent physiology during exposure to high DC magnetic fields. A second objective is to discuss some of the unique instrumentation problems that must be overcome in order to record bioelectric signals from laboratory animals in the presence of a magnetic field. Finally, a description will be given of the various dosimetry techniques that can be employed for quantitation of magnetic field strength

  4. Neutron Scattering and High Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Winn, Barry L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Stone, Matthew B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-11-01

    The workshop “Neutron Scattering and High Magnetic Fields” was held September 4-5, 2014 at the Oak Ridge National Laboratory (ORNL). The workshop was held in response to a recent report by the National Research Council of the National Academy of Sciences entitled “High Magnetic Field Science and Its Application in the United States: Current Status and Future Directions.”1 This report highlights the fact that neutron scattering measurements carried out in high magnetic fields provide important opportunities for new science. The workshop explored the range of the scientific discoveries that could be enabled with neutron scattering measurements at high fields (25 Tesla or larger), the various technologies that might be utilized to build specialized instruments and sample environment equipment to enable this research at ORNL, and possible routes to funding and constructing these facilities and portable high field sample environments.

  5. The sensitivity of RTL, RPL and photographic detectors to 14.7MeV neutrons

    International Nuclear Information System (INIS)

    Spurny, Frantisek; Medioni, Roger; Portal, Guy.

    1975-08-01

    The sensitivity of various types of γ detectors to neutrons should be known for a better dosimetry of electromagnetic radiations in neutron fields. The sensitivity of various types of detectors to 14.7MeV neutrons was studied using RTL (LiF, 7 LiF, Ca SO 4 : Dy Al 2 O) RPL (C.E.C. glasses) and photographic detectors (Kodak-Pathe dosemeters). The methods used for the determination of the neutron and photon mixed field are described and the effect of containers and packing on the accuracy of results was investigated. For each detector studied the specific sensitivity to neutrons (sensitivity of the product alone) and the apparent sensitivity in usual operating conditions (action of surrounding materials) is given [fr

  6. Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-15

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, gamma) process in Na sup 2 sup 3 , giving rise to Na sup 2 sup 4 , which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na sup 2 sup 4 , is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na sup 2 sup 3 in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na sup 2 sup 4 /Na sup 2 sup 3 in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R sub B reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzmann transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given

  7. Research and innovation in radiation dosimetry

    International Nuclear Information System (INIS)

    Delgado, A.

    1999-01-01

    In this article some relevant lines of research in radiation dosimetry are presented. In some of them innovative approaches have been recently proposed in recent years. In others innovation is still to come as it is necessary in view of the insufficiency of the actual methods and techniques. mention is made to Thermoluminescence Dosimetry an to the improvement produced by new computational methods for the analysis of the usually complex TL signals. A solid state dosimetric technique recently proposed, Optically Stimulated Luminescence, OSL, is briefly presented. This technique promises advantages over TLD for personal and environmental dosimetry. The necessity of improving the measurement characteristics of neutron personal dosemeters is commented, making reference to some very recent developments. The situation of the dosimetry in connection with radiobiology research is overviewed, commenting the controversy on the adequacy and utility of the quality absorbed dose for these activities. Finally the special problematic of internal dosimetry is discussed. (Author) 25 refs

  8. Supralinear detectors in neutron dosimetry

    International Nuclear Information System (INIS)

    Larsson, L.; Roth, R.A.; Katz, R.

    1977-01-01

    Dose-response curves for nuclear emulsions exposed to x-rays and neutrons are presented and discussed. Ilford K.5 plates were used to mimic an initial slope model of biological cell survival curves, and Ilford K-2.5 plates were used to mimic the multi-target survival model after gamma-ray irradiation. The plates were exposed to x-rays from a Torrex-150 x-ray unit and fission neutrons at the 18 kW Triga Mark I reactor. Representative calculations for the response of model detectors to 14 MeV neutrons were made for comparison with experimental findings. Results are presented and discussed

  9. Techniques of in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Chettle, D.R.; Fremlin, J.H.

    1984-01-01

    This review is dealt with under the following headings, intended to reflect the different factors affecting the measurement sensitivity, starting with the choice of neutron source and proceeding, through the reaction characteristics, to the detection system, the questions of dosimetry and ethical constraints being also discussed: 1) neutron sources, slowing down and interaction processes, energy spectrum and flux uniformity, timing 2) neutron reactions used for in vivo analyses 3) detectors, choice, geometrical considerations and detector shielding 4) data collection and processing 5) interpretation, major elements, absolute or sequential measurements, relationship to other parameters 6) dosimetry, framework for dose levels, biological effects of neutron interactions, neutron doses in practice 7) implications for measurement of calcium, nitrogen and cadmium. (U.K.)

  10. Problem Oriented Neutron-Gamma Cross Sections Libraries for WWER-440 and WWER-1000 Shielding and Reactor Vessel Dosimetry Application

    International Nuclear Information System (INIS)

    Belousov, S.; Antonov, S.; Ilieva, K.

    1997-01-01

    The 47 neutron and 20 gamma group libraries BGL-440 and BGL-1000 for the shielding and reactor vessel dosimetry application have been generated for WWER-440 and WWER-1000 by collapsing the VITAMIN-B6 library (199 neutron and 42 gamma groups on the base of ENDF/B-6). The first parts of the libraries for neutron-gamma transport calculation, BGL-440-1 (150 nuclides) and BGL-1000-1 (140 nuclides), have been generated by a modified version of SAS1X control module of the SCALE system. The appropriate zone-average neutron flux had been used for these sub-libraries collapsing. The BGL-440-2 and BGL-1000-2 sub-libraries consist of cross sections for all 120 nuclides of VITAMIN-B6, for calculation of the transport through non-reactor materials of dosimeters, capsules, specimens which may be placed in the cavity behind the reactor vessel. The neutron spectrum just beyond the RPV had been used for this collapsing. As the first test the comparative calculations of the neutron flux on/behind the WWER-1000 reactor vessel have been realised using the libraries BGL-1000 and BUGLE, intended for the American PWR reactors. The integral neutron flux values by BGL-1000 and BUGLE differ by 3% onto the vessel, and 5% behind the vessel. This result shows that the calculations of the neutron flux responses for the WWER vessel surveillance, especially in locations behind the WWER vessel have to be done by the appropriate BGL library. Key words: neutron transport, multigroup neutron cross section libraries

  11. Mixed field dosimetry in the FRN exposure-room

    International Nuclear Information System (INIS)

    Jentzsch, U.

    1976-01-01

    The twin ionization chamber technique, chemical dosimeter systems and silicon diodes have been used to determine the neutron and gamma components of the reactor field in the FRN exposure-room. The knowledge of these components are of fundamental importance for irradiation experiments in the biological research program started at the FRN. The chemical systems and silicon diodes have the advantage of low cost and simple handling. Furthermore, silicon diodes have negligible gamma response and the shift of neutron response with variation of neutron energy spectrum is small. The results of measurements with the different methods have been compared and discussed. (author)

  12. The US Department of Energy Personnel Dosimetry Evaluation and Upgrade Program

    International Nuclear Information System (INIS)

    Faust, L.G.; Stroud, C.M.; Swinth, K.L.; Vallario, E.J.

    1987-11-01

    The US Department of Energy (DOE) Personnel Dosimetry Evaluation and Upgrade Program is designed to identify and evaluate dosimetry deficiencies and to conduct innovative research and development programs that will improve overall capabilities, thus ensuring that DOE can comply with applicable standards and regulations for dose measurement. To achieve these goals, two programs were initiated to evaluate and upgrade beta measurement and neutron dosimetry. 3 refs

  13. Correction factors for clinical dosemeters used in dosimetry of large fields

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.

    1989-01-01

    A method for using by physicist for evaluation of irradiation effect in cables connectors of ionization chambers, and the consequent determination of adequate conection factors, for each measure the geometric system, during the realization of large fields radiation dosimetry are studied. (C.G.C.) [pt

  14. Advances in biomedical dosimetry

    International Nuclear Information System (INIS)

    1981-01-01

    Full text: Radiation dosimetry, the accurate determination of the absorbed dose within an irradiated body or a piece of material, is a prerequisite for all applications of ionizing radiation. This has been known since the very first radiation applications in medicine and biology, and increasing efforts are being made by radiation researchers to develop more reliable, effective and safe instruments, and to further improve dosimetric accuracy for all types of radiation used. Development of new techniques and instrumentation was particularly fast in the field of both medical diagnostic and therapeutic radiology. Thus, in Paris in October the IAEA held the latest symposium in its continuing series on dosimetry in medicine and biology. The last one was held in Vienna in 1975. High-quality dosimetry is obviously of great importance for human health, whether the objectives lie in the prevention and control of risks associated with the nuclear industry, in medical uses of radioactive substances or X-ray beams for diagnostic purposes, or in the application of photon, electron or neutron beams in radiotherapy. The symposium dealt with the following subjects: General aspects of dosimetry; Special physical and biomedical aspects; Determination of absorbed dose; Standardization and calibration of dosimetric systems; and Development of dosimetric systems. The forty or so papers presented and the discussions that followed them brought out a certain number of dominant themes, among which three deserve particular mention. - The recent generalization of the International System of Units having prompted a fundamental reassessment of the dosimetric quantities to be considered in calibrating measuring instruments, various proposals were advanced by the representatives of national metrology laboratories to replace the quantity 'exposure' (SI unit = coulomb/kg) by 'Kerma' or 'absorbed dose' (unit joule/kg, the special name of which is 'gray'), this latter being closer to the practical

  15. Advances in electron dosimetry of irregular fields; Avances en dosimetria de electrones de campos irregulares

    Energy Technology Data Exchange (ETDEWEB)

    Mendez V, J. [Departamento de Radioterapia, Instituto de Enfermedades Neoplasicas, Avenida Angamos Este 2520, Lima 34 (Peru)

    1998-12-31

    In this work it is presented an advance in Electron dosimetry of irregular fields for beams emitted by linear accelerators. At present diverse methods exist which are coming to apply in the Radiotherapy centers. In this work it is proposed a method for irregular fields dosimetry. It will be allow to calculate the dose rate absorbed required for evaluating the time for the treatment of cancer patients. Utilizing the results obtained by the dosimetric system, it has been possible to prove the validity of the method describe for 12 MeV energy and for square field 7.5 x 7.5 cm{sup 2} with percentile error less than 1 % . (Author)

  16. SU-E-T-594: Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

    International Nuclear Information System (INIS)

    Chen, Y; Lin, Y; Chen, H; Tsai, H

    2015-01-01

    Purpose: Secondary fast neutrons and gamma rays are mainly produced due to the interaction of the primary proton beam with the beam delivery nozzle. These secondary radiation dose to patients and radiation workers are unwanted. The purpose of this study is to estimate the neutron and gamma dose equivalent out of the treatment volume during the wobbling proton therapy system. Methods: Two types of thermoluminescent (TL) dosimeters, TLD-600 ( 6 LiF: Mg, Ti) and TLD-700 ( 7 LiF: Mg, Ti) were used in this study. They were calibrated in the standard neutron and gamma sources at National Standards Laboratory. Annealing procedure is 400°C for 1 hour, 100°C for 2 hours and spontaneously cooling down to the room temperature in a programmable oven. Two-peak method (a kind of glow curve analysis technique) was used to evaluate the TL response corresponding to the neutron and gamma dose. The TLD pairs were placed outside the treatment field at the neutron-gamma mixed field with 190-MeV proton beam produced by the wobbling system through the polyethylene plate phantom. The results of TLD measurement were compared to the Monte Carlo simulation. Results: The initial experiment results of calculated dose equivalents are 0.63, 0.38, 0.21 and 0.13 mSv per Gy outside the field at the distance of 50, 100, 150 and 200 cm. Conclusion: The TLD-600 and TLD-700 pairs are convenient to estimate neutron and gamma dosimetry during proton therapy. However, an accurate and suitable glow curve analysis technique is necessary. During the wobbling system proton therapy, our results showed that the neutron and gamma doses outside the treatment field are noticeable. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)

  17. SU-E-T-594: Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Lin, Y [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Medical Physics Research Center, Institute for Radiological Research, Chang Gung University / Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan (China); Chen, H [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan (China); Tsai, H [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Medical Physics Research Center, Institute for Radiological Research, Chang Gung University / Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan (China); Healthy Aging Research Center, Chang Gung University, Linkou, Taoyuan, Taiwan (China)

    2015-06-15

    Purpose: Secondary fast neutrons and gamma rays are mainly produced due to the interaction of the primary proton beam with the beam delivery nozzle. These secondary radiation dose to patients and radiation workers are unwanted. The purpose of this study is to estimate the neutron and gamma dose equivalent out of the treatment volume during the wobbling proton therapy system. Methods: Two types of thermoluminescent (TL) dosimeters, TLD-600 ({sup 6}LiF: Mg, Ti) and TLD-700 ({sup 7}LiF: Mg, Ti) were used in this study. They were calibrated in the standard neutron and gamma sources at National Standards Laboratory. Annealing procedure is 400°C for 1 hour, 100°C for 2 hours and spontaneously cooling down to the room temperature in a programmable oven. Two-peak method (a kind of glow curve analysis technique) was used to evaluate the TL response corresponding to the neutron and gamma dose. The TLD pairs were placed outside the treatment field at the neutron-gamma mixed field with 190-MeV proton beam produced by the wobbling system through the polyethylene plate phantom. The results of TLD measurement were compared to the Monte Carlo simulation. Results: The initial experiment results of calculated dose equivalents are 0.63, 0.38, 0.21 and 0.13 mSv per Gy outside the field at the distance of 50, 100, 150 and 200 cm. Conclusion: The TLD-600 and TLD-700 pairs are convenient to estimate neutron and gamma dosimetry during proton therapy. However, an accurate and suitable glow curve analysis technique is necessary. During the wobbling system proton therapy, our results showed that the neutron and gamma doses outside the treatment field are noticeable. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)

  18. Development of advanced radiation monitors for pulsed neutron fields

    CERN Document Server

    AUTHOR|(CDS)2081895

    The need of radiation detectors capable of efficiently measuring in pulsed neutron fields is attracting widespread interest since the 60s. The efforts of the scientific community substantially increased in the last decade due to the increasing number of applications in which this radiation field is encountered. This is a major issue especially at particle accelerator facilities, where pulsed neutron fields are present because of beam losses at targets, collimators and beam dumps, and where the correct assessment of the intensity of the neutron fields is fundamental for radiation protection monitoring. LUPIN is a neutron detector that combines an innovative acquisition electronics based on logarithmic amplification of the collected current signal and a special technique used to derive the total number of detected neutron interactions, which has been specifically conceived to work in pulsed neutron fields. Due to its special working principle, it is capable of overcoming the typical saturation issues encountere...

  19. Neutron stars. [quantum mechanical processes associated with magnetic fields

    Science.gov (United States)

    Canuto, V.

    1978-01-01

    Quantum-mechanical processes associated with the presence of high magnetic fields and the effect of such fields on the evolution of neutron stars are reviewed. A technical description of the interior of a neutron star is presented. The neutron star-pulsar relation is reviewed and consideration is given to supernovae explosions, flux conservation in neutron stars, gauge-invariant derivation of the equation of state for a strongly magnetized gas, neutron beta-decay, and the stability condition for a neutron star.

  20. New Neutron Dosimeter

    CERN Multimedia

    2001-01-01

    CERN has been operating an Individual Dosimetry Service for neutrons for about 35 years. The service was based on nuclear emulsions in the form of film packages which were developed and scanned in the Service. In 1999, the supplier of theses packages informed CERN that they will discontinue production of this material. TIS-RP decided to look for an external service provider for individual neutron dosimetry. After an extensive market survey and an invitation for tender, a supplier that met the stringent technical requirements set up by CERN's host states for personal dosimeters was identified. The new dosimeter is based on a track-etching technique. Neutrons have the capability of damaging plastic material. The microscopic damage centres are revealed by etching them in a strong acid. The resulting etch pits can be automatically counted and their density is proportional to dose equivalent from neutrons. On the technical side, the new dosimeter provides an improved independence of its response from energy and th...

  1. Measurement of fast neutrons in emergency dosimetry by means of plastic badges

    International Nuclear Information System (INIS)

    Lommler, B.; Pitt, E.; Scharmann, A.; Simmer, R.

    1990-01-01

    Over the last few yeas plastic cards have increasingly been introduced as membership and other identity cards. As a rule, they consist of an information carrier wrapped in synthetic material. If such synthetic cover is made of a suitable material, it should be possible to use it for detecting fast neutrons, and to make their traces visible by means of the nuclear track etching method. The properties of the material and angle dependence as well as the influence of wear and tear on the detection behaviour were experimentally studied and evaluated in view of the requirements of emergency dosimetry. Since those plastic cards are normally carried on one's body, they offer the possibility to determine the individual dose. The evaluation of the dosemeters requires a rather long etching process (> 1 h) and the counting of nuclear tracks (manually 10 - 20 minutes). (orig./HP) [de

  2. Geiger-Mueller counter for mixed neutron-gamma beam dosimetry

    International Nuclear Information System (INIS)

    McDonald, J.C.; Ma, I.-C.

    1978-01-01

    A Geiger-Mueller (G-M) dosimeter has been constructed and employed to measure the gamma-ray component of absorbed dose in a cyclotron produced fast neutron field. This instrument is waterproof for measurements in a liquid medium, and read-out is accompanied with any standard scaler. (Auth.)

  3. Nineteenth nuclear accident dosimetry intercomparison study, August 9-13, 1982

    International Nuclear Information System (INIS)

    Greene, R.T.; Sims, C.C.; Swaja, R.E.

    1983-11-01

    The Nineteenth Nuclear Accident Dosimetry Intercomparison Study was held August 9 to 13, 1982, at the Oak Ridge National Laboratory using the Health Physics Research Reactor operated in the pulse mode to simulate nuclear criticality accidents. Participants from eight organizations measured neutron and gamma doses at air stations and on phantoms for three different shielding conditions. Measured results were compared to nuclear industry guidelines for criticality accident dosimeters which suggest accuracies of +-25% for neutron dose and +-20% for gamma dose. Seventy-two percent of the neutron dose measurements using foil activation, sodium activation, hair sulfur activation, and thermoluminescent methods met the guidelines while less than 40% of the gamma dose measurements were within +-20% of reference values. The softest neutron energy spectrum (also lowest neutron/gamma dose ratio) provided the most difficulty in measuring neutron and gamma doses. Results of this study indicate the need for continued intercomparison and testing of nuclear accident dosimetry systems and for training of evaluating personnel. 14 references, 7 figures, 16 tables

  4. Microdosimetry of intermediate energy neutrons in fast neutron fields

    International Nuclear Information System (INIS)

    Saion, E.B.; Watt, D.E.

    1988-01-01

    A coaxial double cylindrical proportional counter has been constructed for microdosimetry of intermediate energy neutrons in mixed fields. Details are given of the measured gas gain and resolution characteristics of the counter for a wide range of anode voltages. Event spectra due to intermediate neutrons in any desired energy band is achieved by an appropriate choice of thickness of the common dividing wall in the counter and by appropriate use of the coincidence, anticoincidence pulse counting arrangements. Calculated estimates indicate that the dose contribution by fast neutrons to the energy deposition events in the intermediate neutron range may be as large as 25%. Empirical procedures being investigated aim to determine the necessary corrections to be applied to the microdose distributions, with a precision of 10%. (author)

  5. Realisation and qualification of a tissue equivalent proportional counter with a multi-cellular geometry for the individual neutron dosimetry

    International Nuclear Information System (INIS)

    Hoflack, Ch.

    1999-01-01

    The present day dosimetry means for radiations with a strong ionization density cannot fulfill the future radioprotection regulations which will require an individual dosimetry with active dosemeters. The aim of this work is the study and development of an individual dosemeter based on a tissue equivalent proportional counter and with a multi-cellular geometry allowing to reach a sensibility equivalent to environmental dosemeters. A pressure regulation bench has been added to the detector in order to reduce the degassing of the detector parts and to reach a sufficient service life for the implementation of the characterization tests. The hole counter system has been adopted for the first prototypes in order to reduce the sensibility of the wires multiplication system with respect to mechanical vibrations. Tests performed with an internal alpha source have shown that a better electrical efficiency can be reached when more severe mechanical limits are adopted during the construction. The dose equivalent response of the prototype for mono-energy neutrons of 144 keV to 2.5 MeV is analyzed experimentally and by simulation. During experiments with normal incidence neutrons, the prototype fulfills the requirements of the CEI N O 1323 standard for energies comprised between 400 keV and 2.5 MeV, while the simulation indicates a satisfactory response up to 200 keV. A preliminary study of the behaviour of the detector with respect to the neutrons incidence indicates that the multi-cellular geometry is efficient for large angles (the sensibility of the prototype is increased by a factor 3). Finally, simulation studies have to be made to optimize the electrical operation and the geometry of the next prototype. (J.S.)

  6. Dosimetry of small electron fields shaped by lead

    International Nuclear Information System (INIS)

    Perez, M.; Hill, R.; Whitaker, M.; Greig, L.; West, M.; Jones, L.

    2000-01-01

    Full text: Electron fields can be used to treat superficial cancers. Field shaping can be achieved by placing lead on the patient surface to minimise the dose to surrounding areas and may improve beam penumbra compared to using standard applicators. However, significant dosimetry changes under high density material edges for electron fields have been reported (W Pohlit and KH Manegold, cited in The Physics of Radiation Therapy, P.M. Khan, 1994). This project evaluated the dosimetry of small dimension electron fields shaped with lead placed on the surface. Comparisons were made between circular lead cutouts (3 and 5cm diameters) and an open electron applicator (5cm diameter). For each of these fields depth doses and profiles were measured using a diode detector in a water phantom, and isodoses were measured using X-Omat film sandwiched within a Solid water phantom. Output factors were measured in the Solid water using a Markus parallel plate ionisation chamber. The effect of the lead thickness on the profiles and output was quantified and the thickness used for the final measurements selected so as to give less than 5% transmission of the primary dose. Penumbral widths for 6MeV and 8MeV using the lead cutouts showed distinct differences compared with the open applicator. At depths of the 90% relative dose the profiles for lead shaped fields showed tighter penumbra widths by an average of 2 mm. This became more pronounced nearer the surface where, at 2mm depth, the difference in penumbral widths was an average of 4mm. The 3cm lead cutouts showed surface dose increases of 6% and 9% for 6MeV and 8 MeV respectively. Depth dose parameters (D max and R 90 ) varied by no more than 2mm between the lead cutouts and the open applicator measurements. Lead can be used to shape electron fields for radiotherapy treatments. Depth dose characteristics do not vary significantly with a 5 cm circular applicator. The penumbral width indicates less isodose spread for the lead cutout

  7. Quality assurance manual for the Department of Energy laboratory accreditation program for personnel dosimetry systems

    International Nuclear Information System (INIS)

    1987-02-01

    The overall purpose of this document is to establish a uniform approach to quality assurance. This will ensure that uniform, high-quality personnel dosimetry practices are followed by the participating testing laboratories. The document presents guidelines for calibrating and maintaining measurement and test equipment (M and TE), calibrating radiation fields, and subsequently irradiating and handling personnel dosimeters in laboratories involved in the DOE dosimetry systems testing program. Radiation energies for which the test procedures apply are photons with approximately 15 keV to 2 MeV, beta particles above 0.3 MeV, neutrons with approximately 1 keV to 2 MeV. 12 refs., 4 tabs

  8. Feasibility study on using imaging plates to estimate thermal neutron fluence in neutron-gamma mixed fields

    International Nuclear Information System (INIS)

    Fujibuchi, T.; Tanabe, Y.; Sakae, T.; Terunuma, T.; Isobe, T.; Kawamura, H.; Yasuoka, K.; Matsumoto, T.; Harano, H.; Nishiyama, J.; Masuda, A.; Nohtomi, A.

    2011-01-01

    In current radiotherapy, neutrons are produced in a photonuclear reaction when incident photon energy is higher than the threshold. In the present study, a method of discriminating the neutron component was investigated using an imaging plate (IP) in the neutron-gamma-ray mixed field. Two types of IP were used: a conventional IP for beta- and gamma rays, and an IP doped with Gd for detecting neutrons. IPs were irradiated in the mixed field, and the photo-stimulated luminescence (PSL) intensity of the thermal neutron component was discriminated using an expression proposed herein. The PSL intensity of the thermal neutron component was proportional to thermal neutron fluence. When additional irradiation of photons was added to constant neutron irradiation, the PSL intensity of the thermal neutron component was not affected. The uncertainty of PSL intensities was approximately 11.4 %. This method provides a simple and effective means of discriminating the neutron component in a mixed field. (authors)

  9. Technical recommendations for the use of thermoluminescence for dosimetry in individual monitoring for photons and electrons from external sources

    International Nuclear Information System (INIS)

    1975-01-01

    The principles of thermoluminescence dosimetry and the role it may play in the field of personnel dosimetry are presented. Technical recommendations are made as an indication of what is generally regarded as good practice and they are intended to be of assistance in avoiding the common sources of error. Errors due to: the detector; the evaluation procedure; the thermal treatment; at the sensitivity of the detector to neutrons. The recommendations are concerned with: the choice of detector material; design of thermoluminescent dosemeters; read-out procedure; reader; handling procedures; dose evaluations; automation; documentation and data handling

  10. Evolution of Neutron Star Magnetic Fields

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    in nuclei. The neutrons are expected to form a 3P superfluid and the protons a 1S ... crust are expected to form a lattice; the electrons are free and highly degenerate, .... the reduced magnetic fields in neutron stars processed in binaries,.

  11. Radiation dosimetry and spectrometry with superheated emulsions

    International Nuclear Information System (INIS)

    D'Errico, Francesco

    2001-01-01

    Detectors based on emulsions of overexpanded halocarbon droplets in tissue equivalent aqueous gels or soft polymers, known as 'superheated drop detectors' or 'bubble (damage) detectors', have been used in radiation detection, dosimetry and spectrometry for over two decades. Recent technological advances have led to the introduction of several instruments for individual and area monitoring: passive integrating meters based on the optical or volumetric registration of the bubbles, and active counters detecting bubble nucleations acoustically. These advances in the instrumentation have been matched by the progress made in the production of stable and well-specified emulsions of superheated droplets. A variety of halocarbons are employed in the formulation of the detectors, and this permits a wide range of applications. In particular, halocarbons with a moderate degree of superheat, i.e. a relatively small difference between their operating temperature and boiling point, can be used in neutron dosimetry and spectrometry since they are only nucleated by energetic heavy ions such as those produced by fast neutrons. More recently, halocarbons with an elevated degree of superheat have been utilised to produce emulsions that nucleate with much smaller energy deposition and detect low linear energy transfer radiations, such as photons and electrons. This paper reviews the detector physics of superheated emulsions and their applications in radiation measurements, particularly in neutron dosimetry and spectrometry

  12. Dosimetry and stability studies of the boron neutron capture therapy agent F-BPA-Fr using PET and MRI

    Science.gov (United States)

    Dyke, Jonathan Paul

    The treatment of deep seated brain tumors such as glioblastoma Multiforme has been unsuccessful for many patients. Surgical debulking, chemotherapy and standard radiotherapy have met with limited success. Boron neutron capture therapy offers a binary mode brachytherapy based on the following capture reaction that may provide an innovative alternative to standard forms of treatment:10B + n /to/ 11B /to 7Li + 4He + 2.31 MeVBoron is chemically attached to a tumor binding compound creating a non-toxic neutron absorber. A dose of epithermal neutrons provides the catalyst to produce the lithium and alpha particles which destroy any tissue within a length of one cell diameter from the boron compound. This dissertation uses 19F-MRI and 18F-PET to provide answers to the localization and biodistribution questions that arise in such a treatment modality. Practical patient dosimetry and actual treatment planning using the PET data is also examined. Finally, theoretical work done in the areas of compartmental modelling dealing with pharmacokinetic uptake of the PET radiotracer and dose analysis in microdosimetry is also presented.

  13. Simultaneous neutron and gamma spectrum adjustment

    International Nuclear Information System (INIS)

    Remec, I.

    1996-01-01

    The spectrum adjustment procedure was extended to simultaneous neutron and gamma spectrum adjustment, and the feasibility of this technique is demonstrated in the analysis of HFIR dosimetry experiments. Conditions in which gamma rays may contribute considerably to radiation damage in steels are discussed. Beryllium helium accumulation fluence monitors (HAFMs) were found to be good monitors in gamma fields of intensities high enough to contribute to steel embrittlement. Use of 237 Np, 238 U, and 9 Be HAFM as gamma dosimeters is proposed for high-dose irradiations in high-energy, high-intensity gamma fields

  14. Numerical and experimental results of the operational neutron dosemeter 'Saphydose-N'

    International Nuclear Information System (INIS)

    Lahaye, T.; Chau, Q.; Menard, S.; Ndontcheung-Moyo, M.; Bolognese-Milsztajn, T.; Rannou, A.

    2004-01-01

    Since 1993, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricite de France (EDF), a R and D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics. (authors)

  15. Review of radiation dosimetry research at the University of Wisconsin during 1961-1982

    International Nuclear Information System (INIS)

    Cameron, J.R.; Moran, P.R.; Attix, F.H.

    1982-01-01

    The report provides a comprehensive review of the overall activities in this program since 1961. Research areas have included the development and use of lithium fluoride for thermoluminescent dosimetry, solid state neutron dosimetry, and ionization chamber research

  16. Dosimetric properties of the fast neutron therapy beams at TAMVEC

    International Nuclear Information System (INIS)

    Almond, P.R.; Smith, A.R.; Smathers, J.R.; Otte, V.A.

    1975-01-01

    In October 1972, M.D. Anderson Hospital and Tumor Institute of the University of Texas System Cancer Center initiated a clinical trial of fast neutron radiotherapy using the cyclotron at Texas A and M University. Initially, the study used neutrons produced by bombarding beryllium with 16 MeV deuterons, but since March, 1973, neutrons from 50 MeV deuterons have been used. The dosimetric properties of the 30 MeV beams have also been measured for comparison with the neutron beams from D-T generators. The three beams are compared in terms of dose rate, skin sparing, depth dose and field flatness. Isodose curves for treatment planning were generated using the decrement line method and compared to curves measured by a computer controlled isodose plotter. This system was also used to measure the isodose curves for wedge fields. Dosimetry checks on various patients were made using silicon diodes as in vivo fast neutron dosimeters

  17. A new Recoil Proton Telescope for energy and fluence measurement of fast neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Lebreton, Lena; Bachaalany, Mario [IRSN / LMDN (Institut de Radioprotection et de Surete nucleaire / Laboratoire de Metrologie et de dosimetrie des neutrons), Cadarache Bat.159, 13115 Saint Paul-lez-Durance, (France); Husson, Daniel; Higueret, Stephane [IPHC / RaMsEs (Institut Pluridisciplinaire Hubert Curien / Radioprotection et Mesures Environnementales), 23 rue du loess - BP28, 67037 Strasbourg cedex 2, (France)

    2015-07-01

    The spectrometer ATHENA (Accurate Telescope for High Energy Neutron metrology Applications), is being developed at the IRSN / LMDN (Institut de Radioprotection et de Surete nucleaire / Laboratoire de Metrologie et de dosimetrie des neutrons) and aims at characterizing energy and fluence of fast neutron fields. The detector is a Recoil Proton Telescope and measures neutron fields in the range of 5 to 20 MeV. This telescope is intended to become a primary standard for both energy and fluence measurements. The neutron detection is achieved by a polyethylene radiator for n-p conversion, three 50{sub m} thick silicon sensors that use CMOS technology for the proton tracking and a 3 mm thick silicon diode to measure the residual proton energy. This first prototype used CMOS sensors called MIMOSTAR, initially developed for heavy ion physics. The use of CMOS sensors and silicon diode increases the intrinsic efficiency of the detector by a factor of ten compared with conventional designs. The first prototype has already been done and was a successful study giving the results it offered in terms of energy and fluence measurements. For mono energetic beams going from 5 to 19 MeV, the telescope offered an energy resolution between 5 and 11% and fluence difference going from 5 to 7% compared to other home standards. A second and final prototype of the detector is being designed. It will hold upgraded CMOS sensors called FastPixN. These CMOS sensors are supposed to run 400 times faster than the older version and therefore give the telescope the ability to support neutron flux in the order of 107 to 108cm{sup 2}:s{sup 1}. The first prototypes results showed that a 50 m pixel size is enough for a precise scattering angle reconstruction. Simulations using MCNPX and GEANT4 are already in place for further improvements. A DeltaE diode will replace the third CMOS sensor and will be installed right before the silicon diode for a better recoil proton selection. The final prototype with

  18. Fifteenth nuclear accident dosimetry intercomparison study: August 14--22, 1978

    International Nuclear Information System (INIS)

    Sims, C.S.

    1979-05-01

    The fifteenth in the continuing series of Nuclear Accident Dosimetry Intercomparison Studies was held August 14--22, 1978 at the Oak Ridge National Laboratory. The Health Physics Research Reactor, operated in the pulse mode, served as the radiation source. Using different shielding configurations, nuclear accidents with three different neutron and gamma spectra were simulated. Participants from 19 organizations, the most in the history of the studies, exposed dosimeters set up as area monitors as well as dosimeters mounted on phantoms for personnel monitoring. Although many participants performed accurate measurements, the composite dose results, in the majority of cases, failed to meet established nuclear criticality accident dosimetry guidelines which suggest accuracies of +- 25% for neutron dose and +- 20% for gamma dose. This indicates that many participants need to improve their dosimetry systems, their analytical techniques, or both

  19. Summary report of technical meeting on neutron cross section covariances

    International Nuclear Information System (INIS)

    Trkov, A.; Smith, D.L.; Capote Noy, R.

    2011-01-01

    A summary is given of the Technical Meeting on Neutron Cross Section Covariances. The meeting goal was to assess covariance data needs and recommend appropriate methodologies to address those needs. Discussions on covariance data focused on three general topics: 1) Resonance and unresolved resonance regions; 2) Fast neutron region; and 3) Users' perspective: benchmarks' uncertainty and reactor dosimetry. A number of recommendations for further work were generated and the important work that remains to be done in the field of covariances was identified. (author)

  20. New neutron cross sections for fusion materials studies

    International Nuclear Information System (INIS)

    Greenwood, L.R.; Smither, R.K.

    1985-01-01

    Neutron cross sections are being developed for a variety of fusion-related applications including neutron dosimetry, fusion plasma diagnostics, the activation of very long-lived isotopes, and high-energy accelerator neutron sources