WorldWideScience

Sample records for neutron collar calibration

  1. Prototype Stilbene Neutron Collar

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, M. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shumaker, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Snyderman, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Verbeke, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wong, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-26

    A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation of list mode neutron correlation data on various fuel assemblies including some with neutron absorbers (burnable Gd poisons). Calibration curves (doubles vs 235U linear mass density) are presented for both thermal and fast (with Cd lining) modes of operation. It is shown that the stilbene collar meets or exceeds the current capabilities of He-3 based neutron collars. A self-consistent assay methodology, uniquely suited to the stilbene collar, using triples is described which complements traditional assay based on doubles calibration curves.

  2. Neutron collar calibration for assay of LWR [light-water reactor] fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Pieper, J.E.

    1987-03-01

    The neutron-coincidence collar is used for the verification of the uranium content in light-water reactor fuel assemblies. An AmLi neutron source is used to give an active interrogation of the fuel assembly to measure the 235 U content, and the 238 U content is verified from a passive neutron-coincidence measurement. This report gives the collar calibration data of pressurized-water reactor and boiling-water reactor fuel assemblies. Calibration curves and correction factors are presented for neutron absorbers (burnable poisons) and different fuel assembly sizes. The data were collected at Exxon Nuclear, Franco-Belge de Fabrication de Combustibles, ASEA-Atom, and other nuclear fuel fabrication facilities

  3. Effect of double false pulses in calibrated neutron coincidence collar during measuring time-correlated neutrons from PuBe neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Tam Cong, E-mail: tam.nguyen.cong@energia.mta.hu; Huszti, Jozsef; Nguyen, Quan Van

    2015-09-01

    Effect of double false pulses of preamplifiers in neutron coincidence collar was investigated to explain non-parallel shape of calibrated D/S–M{sub Pu} curves of two commercial neutron coincidence collars, JCC-31 and JCC-13. Two curves, which were constructed from D/S ratio (doubles and singles count rate), and Pu content M{sub Pu}, of the same set of secondary standard PuBe neutron sources, should be parallel. Non-parallelism rises doubt about usability of the method based on this curve for determination of Pu content in PuBe neutron sources. We have shown in three steps that the problem originates from double false pulses of preamplifiers in JCC-13. First we used a pulse train diagram for analyzing the non-parallel shape, second we used Rossi-Alpha distribution measured by pulse train recorder developed in our institute and finally, we investigated the effect of inserted noise pulses. This implies a new type of QA test option in traditional multiplicity shift registers for excluding presence of double false pulses.

  4. Neutron Collar Evolution and Fresh PWR Assembly Measurements with a New Fast Neutron Passive Collar

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Geist, William H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Root, Margaret A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rael, Carlos D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Belian, Anthony P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-02

    The passive neutron collar approach removes the effect of poison rods when using a 1mm Gd liner. This project sets out to solve the following challenges: BWR fuel assemblies have less mass and less neutron multiplication than PWR; and effective removal of cosmic ray spallation neutron bursts needed via QC tests.

  5. Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

    International Nuclear Information System (INIS)

    Hu, Jianwei; Croft, Stephen; McElroy, Robert Dennis

    2017-01-01

    The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non- 3 He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235 U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

  6. Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-01-01

    The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non-3He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

  7. Determination of U-235 quantity in fresh fuel elements by neutron coincidence collar technique

    International Nuclear Information System (INIS)

    Almeida, M.C.M. de; Almeida, S.G. de; Marzo, M.A.S.; Moita, L.P.M.

    1990-01-01

    The U-235 quantity per lenght of fresh fuel assemblies of the Angra-I first recharge was determined by Neutron Coincidence Collar technique (N.C.C.). This technique is well-founded in fresh fuel assemblies activation by thermal neutrons from AmLi source to generate U-235 fission neutrons. These neutrons are detected by coincidence method in polyethylene structure where 18 He-3 detectors were placed. The coincidence counting results, in active mode (AmLi), showed 0,7% to standard deviation and equal to 1,49% to mass in 1000s of counting. The accuracies of different calibration methods were evaluated and compared. The results showed that the operator declared values are consistent. This evaluation was part of technical-exchange program between Safeguards Laboratory from C.N.E.N. and Los Alamos National Lab., United States. (author)

  8. Simulations of a PSD Plastic Neutron Collar for Assaying Fresh Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Hausladen, Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    The potential performance of a notional active coincidence collar for assaying uranium fuel based on segmented detectors constructed from the new PSD plastic fast organic scintillator with pulse shape discrimination capability was investigated in simulation. Like the International Atomic Energy Agency's present Uranium Neutron Collar for LEU (UNCL), the PSD plastic collar would also function by stimulating fission in the 235U content of the fuel with a moderated 241Am/Li neutron source and detecting instances of induced fission via neutron coincidence counting. In contrast to the moderated detectors of the UNCL, the fast time scale of detection in the scintillator eliminates statistical errors due to accidental coincidences that limit the performance of the UNCL. However, the potential to detect a single neutron multiple times historically has been one of the properties of organic scintillator detectors that has prevented their adoption for international safeguards applications. Consequently, as part of the analysis of simulated data, a method was developed by which true neutron-neutron coincidences can be distinguished from inter-detector scatter that takes advantage of the position and timing resolution of segmented detectors. Then, the performance of the notional simulated coincidence collar was evaluated for assaying a variety of fresh fuels, including some containing burnable poisons and partial defects. In these simulations, particular attention was paid to the analysis of fast mode measurements. In fast mode, a Cd liner is placed inside the collar to shield the fuel from the interrogating source and detector moderators, thereby eliminating the thermal neutron flux that is most sensitive to the presence of burnable poisons that are ubiquitous in modern nuclear fuels. The simulations indicate that the predicted precision of fast mode measurements is similar to what can be achieved by the present UNCL in thermal mode. For example, the

  9. Description and performance characteristics for the neutron Coincidence Collar for the verification of reactor fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1981-08-01

    An active neutron interrogation method has been developed for the measurement of 235 U content in fresh fuel assemblies. The neutron Coincidence Collar uses neutron interrogation with an AmLi neutron source and coincidence counting the induced fission reaction neutrons from the 235 U. This manual describes the system components, operation, and performance characteristics. Applications of the Coincidence Collar to PWR and BWR types of reactor fuel assemblies are described

  10. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-01-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next

  11. A new fast neutron collar for safeguards inspection measurements of fresh low enriched uranium fuel assemblies containing burnable poison rods

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Louise G., E-mail: evanslg@ornl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Swinhoe, Martyn T.; Menlove, Howard O. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Schwalbach, Peter; Baere, Paul De [European Commission, Euratom Safeguards Office (Luxembourg); Browne, Michael C. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-11-21

    Safeguards inspection measurements must be performed in a timely manner in order to detect the diversion of significant quantities of nuclear material. A shorter measurement time can increase the number of items that a nuclear safeguards inspector can reliably measure during a period of access to a nuclear facility. In turn, this improves the reliability of the acquired statistical sample, which is used to inform decisions regarding compliance. Safeguards inspection measurements should also maintain independence from facility operator declarations. Existing neutron collars employ thermal neutron interrogation for safeguards inspection measurements of fresh fuel assemblies. A new fast neutron collar has been developed for safeguards inspection measurements of fresh low-enriched uranium (LEU) fuel assemblies containing gadolinia (Gd{sub 2}O{sub 3}) burnable poison rods. The Euratom Fast Collar (EFC) was designed with high neutron detection efficiency to make a fast (Cd) mode measurement viable whilst meeting the high counting precision and short assay time requirements of the Euratom safeguards inspectorate. A fast mode measurement reduces the instrument sensitivity to burnable poison rod content and therefore reduces the applied poison correction, consequently reducing the dependence on the operator declaration of the poison content within an assembly. The EFC non-destructive assay (NDA) of typical modern European pressurized water reactor (PWR) fresh fuel assembly designs have been simulated using Monte Carlo N-particle extended transport code (MCNPX) simulations. Simulations predict that the EFC can achieve 2% relative statistical uncertainty on the doubles neutron counting rate for a fast mode measurement in an assay time of 600 s (10 min) with the available {sup 241}AmLi (α,n) interrogation source strength of 5.7×10{sup 4} s{sup −1}. Furthermore, the calibration range of the new collar has been extended to verify {sup 235}U content in variable PWR fuel

  12. A new fast neutron collar for safeguards inspection measurements of fresh low enriched uranium fuel assemblies containing burnable poison rods

    International Nuclear Information System (INIS)

    Evans, Louise G.; Swinhoe, Martyn T.; Menlove, Howard O.; Schwalbach, Peter; Baere, Paul De; Browne, Michael C.

    2013-01-01

    Safeguards inspection measurements must be performed in a timely manner in order to detect the diversion of significant quantities of nuclear material. A shorter measurement time can increase the number of items that a nuclear safeguards inspector can reliably measure during a period of access to a nuclear facility. In turn, this improves the reliability of the acquired statistical sample, which is used to inform decisions regarding compliance. Safeguards inspection measurements should also maintain independence from facility operator declarations. Existing neutron collars employ thermal neutron interrogation for safeguards inspection measurements of fresh fuel assemblies. A new fast neutron collar has been developed for safeguards inspection measurements of fresh low-enriched uranium (LEU) fuel assemblies containing gadolinia (Gd 2 O 3 ) burnable poison rods. The Euratom Fast Collar (EFC) was designed with high neutron detection efficiency to make a fast (Cd) mode measurement viable whilst meeting the high counting precision and short assay time requirements of the Euratom safeguards inspectorate. A fast mode measurement reduces the instrument sensitivity to burnable poison rod content and therefore reduces the applied poison correction, consequently reducing the dependence on the operator declaration of the poison content within an assembly. The EFC non-destructive assay (NDA) of typical modern European pressurized water reactor (PWR) fresh fuel assembly designs have been simulated using Monte Carlo N-particle extended transport code (MCNPX) simulations. Simulations predict that the EFC can achieve 2% relative statistical uncertainty on the doubles neutron counting rate for a fast mode measurement in an assay time of 600 s (10 min) with the available 241 AmLi (α,n) interrogation source strength of 5.7×10 4 s −1 . Furthermore, the calibration range of the new collar has been extended to verify 235 U content in variable PWR fuel designs in the presence of up to

  13. In-plant test and evaluation of the neutron collar for verification of PWR fuel assemblies at Resende, Brazil

    International Nuclear Information System (INIS)

    Menlove, H.O.; Marzo, M.A.S.; de Almeida, S.G.; de Almeida, M.C.; Moitta, L.P.M.; Conti, L.F.; de Paiva, J.R.T.

    1985-11-01

    The neutron-coincidence collar has been evaluated for the measurement of pressurized-water reactor (PWR) fuel assemblies at the Fabrica de Elementos Combustiveis plant in Resende, Brazil. This evaluation was part of the cooperative-bilateral-safeguards technical-exchange program between the United States and Brazil. The neutron collar measures the 235 U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The 238 U content is measured in the passive mode without the AmLi neutron-interrogation source. The extended evaluation took place over a period of 6 months with both scanning and single-zone measurements. The results of the tests gave a coincidence-response standard deviation of 0.7% (sigma = 1.49% for mass) for the active case and 2.5% for the passive case in 1000-s measurement times. The length measurement in the scanning mode was accurate to 0.77%. The accuracies of different calibration methods were evaluated and compared

  14. 1987 calibration of the TFTR neutron spectrometers

    International Nuclear Information System (INIS)

    Barnes, C.W.; Strachan, J.D.; Princeton Univ., NJ

    1989-12-01

    The 3 He neutron spectrometer used for measuring ion temperatures and the NE213 proton recoil spectrometer used for triton burnup measurements were absolutely calibrated with DT and DD neutron generators placed inside the TFTR vacuum vessel. The details of the detector response and calibration are presented. Comparisons are made to the neutron source strengths measured from other calibrated systems. 23 refs., 19 figs., 6 tabs

  15. Calibration of detector efficiency of neutron detector

    International Nuclear Information System (INIS)

    Guo Hongsheng; He Xijun; Xu Rongkun; Peng Taiping

    2001-01-01

    BF 3 neutron detector has been set up. Detector efficiency is calibrated by associated particle technique. It is about 3.17 x 10 -4 (1 +- 18%). Neutron yield of neutron generator per pulse (10 7 /pulse) is measured by using the detector

  16. Guidelines on calibration of neutron measuring devices

    International Nuclear Information System (INIS)

    Burger, G.

    1988-01-01

    The International Atomic Energy Agency and the World Health Organization have agreed to establish an IAEA/WHO Network of Secondary Standard Dosimetry Laboratories (SSDLs) in order to improve accuracy in applied radiation dosimetry throughout the world. These SSDLs must be equipped with, and maintain, secondary standard instruments, which have been calibrated against primary standards, and must be nominated by their governments for membership of the network. The majority of the existing SSDLs were established primarily to work with photon radiation (X-rays and gamma rays). Neutron sources are, however, increasingly being applied in industrial processes, research, nuclear power development and radiation biology and medicine. Thus, it is desirable that the SSDLs in countries using neutron sources on a regular basis should also fulfil the minimum requirements to calibrate neutron measuring devices. It is the primary purpose of this handbook to provide guidance on calibration of instruments for radiation protection. A calibration laboratory should also be in a position to calibrate instrumentation being used for the measurement of kerma and absorbed dose and their corresponding rates. This calibration is generally done with photons. In addition, since each neutron field is usually contaminated by photons produced in the source or by scatter in the surrounding media, neutron protection instrumentation has to be tested with respect to its intrinsic photon response. The laboratory will therefore need to possess equipment for photon calibration. This publication deals primarily with methods of applying radioactive neutron sources for calibration of instrumentation, and gives an indication of the space, manpower and facilities needed to fulfil the minimum requirements of a calibration laboratory for neutron work. It is intended to serve as a guide for centres about to start on neutron dosimetry standardization and calibration. 94 refs, 8 figs, 12 tabs

  17. Calibration and evaluation of neutron moisturemeter

    International Nuclear Information System (INIS)

    Tang Zhangxiong; Hu Jiangchao; Sun Laiyan; Wang Huaihui; Wu Weixue

    1992-02-01

    Factors influencing the calibration curve of neutron moisture meter, such as soil type, texture, volume weight and depth, were studied. When the soil bulk density water content is between 15% to 45%, the calibration curve is approximately a straight line, and the intercept and slope are only influenced by the above factors. The growing plants also influence the calibration curve slightly. The measuring error for top soil (< 20 cm) is larger. The relative error between neutron method and weighing method is about 8%. The neutron method has many advantages such as non-interfering, simple, fast and non-time-delay

  18. Quality of the neutron probe calibration curve

    International Nuclear Information System (INIS)

    Libardi, Paulo Leonel; Moraes, Sergio Oliveira

    1997-01-01

    An experiment of neutron probe calibration has been performed, involving various volume size samples and collected at various distances from the access tubes. The experiment aimed to give some answers to questions such as suitable sample physical volume, always use of the same volume and sample distance from the neutron probe access tube

  19. Calibration of an electron volt neutron spectrometer

    International Nuclear Information System (INIS)

    Mayers, J.; Adams, M.A.

    2011-01-01

    The procedure for calibrating the VESUVIO eV neutron spectrometer at the ISIS neutron source is described. VESUVIO is used primarily to measure the momentum distribution n(p) of atoms, by inelastic scattering of very high energy (5-150 eV) neutrons. The results of the calibrations show that measurements of n(p) in atoms with masses lower than 16 amu can be measured with a resolution width ∼25% of the intrinsic peak widths in the current instrument configuration. Some suggestions as to how the instrument resolution could be significantly improved are made.

  20. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  1. Development of neutron calibration field using accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Mamoru [Tohoku Univ., Cyclotron and Radioisotope Center, Sendai, Miyagi (Japan)

    2003-03-01

    A brief summary is given on the fast neutron calibration fields for 1) 8 keV to 15 MeV range, and 2) 30-80 MeV range. The field for 8 keV to 15 MeV range was developed at the Fast Neutron Laboratory (FNL) at Tohoku University using a 4.5 MV pulsed Dynamitron accelerator and neutron production reactions, {sup 45}Sc(p, n), {sup 7}Li(p, n), {sup 3}H(p, n), D(d, n) and T(d, n). The latter 30-80 MeV fields are setup at TIARA of Takasaki Establishment of Japan Atomic Energy Research Institute, and at Cyclotron Radio Isotope Center (CYRIC) of Tohoku University using a 90 MeV AVF cyclotron and the {sup 7}Li(p, n) reaction. These fields have been applied for various calibration of neutron spectrometers and dosimeters, and for irradiation purposes. (author)

  2. In situ calibration of TFTR neutron detectors

    International Nuclear Information System (INIS)

    Hendel, H.W.; Palladino, R.W.; Barnes, C.W.; Diesso, M.; Felt, J.S.; Jassby, D.L.; Johnson, L.C.; Ku, L.; Liu, Q.P.; Motley, R.W.; Murphy, H.B.; Murphy, J.; Nieschmidt, E.B.; Roberts, J.A.; Saito, T.; Strachan, J.D.; Waszazak, R.J.; Young, K.M.

    1990-01-01

    We report results of the TFTR fission detector calibration performed in December 1988. A NBS-traceable, remotely controlled 252 Cf neutron source was moved toroidally through the TFTR vacuum vessel. Detection efficiencies for two 235 U detectors were measured for 930 locations of the neutron point source in toroidal scans at 16 different major radii and vertical heights. These scans effectively simulated the volume-distributed plasma neutron source and the volume-integrated detection efficiency was found to be insensitive to plasma position. The Campbell mode is useful due to its large overlap with the count rate mode and large dynamic range. The resulting absolute plasma neutron source calibration has an uncertainty of ±13%

  3. Pulsed neutron activation calibration technique

    International Nuclear Information System (INIS)

    Kehler, P.

    1979-01-01

    A pulsed neutron activation (PNA) for measurement of two-phase flow consists of a pulsed source of fast neutron to activate the oxygen in a steam-water mixture. Flow is measured downstream by an NaI detector. Measured counts are sorted by a multiscaler into different time channels. A counts vs. time distribution typical for two-phase flow with slip between the two phases is obtained. Proper evaluation for the counts/time distribution leads to flow-regime independent equations for the average of the inverse transil time and the average density. After calculation of the average mass flow velocity, the true mass flow is derived

  4. Field test and evaluation of the passive neutron coincidence collar for prototype fast reactor fuel subassemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-08-01

    The passive neutron Coincidence Collar, which was developed for the verification of plutonium content in fast reactor fuel subassemblies, has been field tested using Prototype Fast Reactor fuel. For passive applications, the system measures the 240 Pu-effective mass from the spontaneous fission rate, and in addition, a self-interrogation technique is used to determine the fissile content in the subassembly. Both the passive and active modes were evaluated at the Windscale Works in the United Kingdom. The results of the tests gave a standard deviation 0.75% for the passive count and 3 to 7% for the active measurement for a 1000-s counting time. The unit will be used in the future for the verification of plutonium in fresh fuel assemblies

  5. Calibration of the neutron scintillation counter threshold

    International Nuclear Information System (INIS)

    Noga, V.I.; Ranyuk, Yu.N.; Telegin, Yu.N.

    1978-01-01

    A method for calibrating the threshold of a neutron counter in the form of a 10x10x40 cm plastic scintillator is described. The method is based on the evaluation of the Compton boundary of γ-spectrum from the discrimination curve of counter loading. The results of calibration using 60 Co and 24 Na γ-sources are given. In order to eValuate the Compton edge rapidly, linear extrapolation of the linear part of the discrimination curve towards its intersection with the X axis is recommended. Special measurements have shown that the calibration results do not practically depend on the distance between the cathode of a photomultiplier and the place where collimated γ-radiation of the calibration source reaches the scintillator

  6. Fiber optic neutron imaging system: calibration

    International Nuclear Information System (INIS)

    Malone, R.M.; Gow, C.E.; Thayer, D.R.

    1981-01-01

    Two neutron imaging experiments using fiber optics have been performed at the Nevada Test Site. In each experiment, an array of scintillator fluor tubes is exposed to neutrons. Light is coupled out through radiation resistant PCS fibers (8-m long) into high-bandwidth, graded index fibers. For image reconstruction to be accurate, common timing differences and transmission variations between fiber optic channels are needed. The calibration system featured a scanning pulsed dye laser, a specially designed fiber optic star coupler, a tektronix 7912AD transient digitizer, and a DEC PDP 11/34 computing system

  7. Measurements for the energy calibration of the TANSY neutron detectors

    International Nuclear Information System (INIS)

    Drozdowicz, K.; Hoek, M.; Aronsson, D.

    1990-05-01

    The report describes measurements performed for the energy calibration of the TANSY neutron detectors (two arrays of 16 detectors each one). The calibration procedure determines four calibration parameters for each detector. Results of the calibration measurements are given and test measurements are presented. A relation of the neutron detector calibration parameters to producer's data for the photomulipliers is analysed. Also the tests necessary during normal operation of the TANSY neutron spectrometer are elaborated (passive and active tests). A method how to quickly get the calibration parameters for a spare detector in an array of the neutron detectors is included

  8. Calibration and intercomparison of neutron moderation spectrometers

    International Nuclear Information System (INIS)

    Rimpler, A.; Hermanska, J.; Prouza, Z.

    1989-01-01

    Results have been reported of comparative measurements of neutron fields from bare PuBe and Cf sources using multisphere (Bonner) spectrometers. The experiments were carried out by the Institute of Biophysics and Nuclear Medicine at Charles University in Prague and the National Board for Atomic Safety and Radiation Protection in Berlin. Both sides agreed upon uniform measuring conditions and calibration factors thus rendering possible the comparability of the dosimetric parameters which have been determined and verified, respectively, to an accuracy of ± 10%. 20 refs., 10 tabs., 2 figs. (author)

  9. 14 MeV calibration of JET neutron detectors—phase 1: calibration and characterization of the neutron source

    Science.gov (United States)

    Batistoni, P.; Popovichev, S.; Cufar, A.; Ghani, Z.; Giacomelli, L.; Jednorog, S.; Klix, A.; Lilley, S.; Laszynska, E.; Loreti, S.; Packer, L.; Peacock, A.; Pillon, M.; Price, R.; Rebai, M.; Rigamonti, D.; Roberts, N.; Tardocchi, M.; Thomas, D.; Contributors, JET

    2018-02-01

    In view of the planned DT operations at JET, a calibration of the JET neutron monitors at 14 MeV neutron energy is needed using a 14 MeV neutron generator deployed inside the vacuum vessel by the JET remote handling system. The target accuracy of this calibration is  ±10% as also required by ITER, where a precise neutron yield measurement is important, e.g. for tritium accountancy. To achieve this accuracy, the 14 MeV neutron generator selected as the calibration source has been fully characterised and calibrated prior to the in-vessel calibration of the JET monitors. This paper describes the measurements performed using different types of neutron detectors, spectrometers, calibrated long counters and activation foils which allowed us to obtain the neutron emission rate and the anisotropy of the neutron generator, i.e. the neutron flux and energy spectrum dependence on emission angle, and to derive the absolute emission rate in 4π sr. The use of high resolution diamond spectrometers made it possible to resolve the complex features of the neutron energy spectra resulting from the mixed D/T beam ions reacting with the D/T nuclei present in the neutron generator target. As the neutron generator is not a stable neutron source, several monitoring detectors were attached to it by means of an ad hoc mechanical structure to continuously monitor the neutron emission rate during the in-vessel calibration. These monitoring detectors, two diamond diodes and activation foils, have been calibrated in terms of neutrons/counts within  ±5% total uncertainty. A neutron source routine has been developed, able to produce the neutron spectra resulting from all possible reactions occurring with the D/T ions in the beam impinging on the Ti D/T target. The neutron energy spectra calculated by combining the source routine with a MCNP model of the neutron generator have been validated by the measurements. These numerical tools will be key in analysing the results from the in

  10. Design of calibration method in neutron and individual dosimeter

    International Nuclear Information System (INIS)

    Belkhodia, M.

    1984-12-01

    Usually albedo dosemeters are calibrated with beam of monoenergetic neutrons. Since neutron energy around neutron sources varies greatly, we applied the calibration method to a mixed field whose energy spectrum lies between 0.025 ev and 10 Mev. The method is based on a mathematical model that deals with the dosimeter response as a function at the neutron energy. The measurements carried out with solid state nuclear track detectors show the dosimeter practical aspect. The albedo dosimeter calibration gave results on good agreement with the international institution recommendations

  11. Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

    Science.gov (United States)

    Gaganov, V. V.; Usenko, P. L.; Kryzhanovskaja, M. A.

    2017-12-01

    Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

  12. Calibration of a compact magnetic proton recoil neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jianfu, E-mail: zhang_jianfu@163.com [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an 710049 (China); Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Ouyang, Xiaoping; Zhang, Xianpeng [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an 710049 (China); Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Ruan, Jinlu [Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Zhang, Guoguang [Applied Institute of Nuclear Technology, China Institute of Atomic Energy, Beijing 102413 (China); Zhang, Xiaodong [Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Qiu, Suizheng, E-mail: szqiu@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an 710049 (China); Chen, Liang; Liu, Jinliang; Song, Jiwen; Liu, Linyue; Yang, Shaohua [Northwest Institute of Nuclear Technology, Xi' an 710024 (China)

    2016-04-21

    Magnetic proton recoil (MPR) neutron spectrometer is considered as a powerful instrument to measure deuterium–tritium (DT) neutron spectrum, as it is currently used in inertial confinement fusion facilities and large Tokamak devices. The energy resolution (ER) and neutron detection efficiency (NDE) are the two most important parameters to characterize a neutron spectrometer. In this work, the ER calibration for the MPR spectrometer was performed by using the HI-13 tandem accelerator at China Institute of Atomic Energy (CIAE), and the NDE calibration was performed by using the neutron generator at CIAE. The specific calibration techniques used in this work and the associated accuracies were discussed in details in this paper. The calibration results were presented along with Monte Carlo simulation results.

  13. Calibration of neutron detectors on the Joint European Torus.

    Science.gov (United States)

    Batistoni, Paola; Popovichev, S; Conroy, S; Lengar, I; Čufar, A; Abhangi, M; Snoj, L; Horton, L

    2017-10-01

    The present paper describes the findings of the calibration of the neutron yield monitors on the Joint European Torus (JET) performed in 2013 using a 252 Cf source deployed inside the torus by the remote handling system, with particular regard to the calibration of fission chambers which provide the time resolved neutron yield from JET plasmas. The experimental data obtained in toroidal, radial, and vertical scans are presented. These data are first analysed following an analytical approach adopted in the previous neutron calibrations at JET. In this way, a calibration function for the volumetric plasma source is derived which allows us to understand the importance of the different plasma regions and of different spatial profiles of neutron emissivity on fission chamber response. Neutronics analyses have also been performed to calculate the correction factors needed to derive the plasma calibration factors taking into account the different energy spectrum and angular emission distribution of the calibrating (point) 252 Cf source, the discrete positions compared to the plasma volumetric source, and the calibration circumstances. All correction factors are presented and discussed. We discuss also the lessons learnt which are the basis for the on-going 14 MeV neutron calibration at JET and for ITER.

  14. Fusion neutron detector calibration using a table-top laser generated plasma neutron source

    International Nuclear Information System (INIS)

    Hartke, R.; Symes, D.R.; Buersgens, F.; Ruggles, L.E.; Porter, J.L.; Ditmire, T.

    2005-01-01

    Using a high intensity, femtosecond laser driven neutron source, a high-sensitivity neutron detector was calibrated. This detector is designed for observing fusion neutrons at the Z accelerator in Sandia National Laboratories. Nuclear fusion from laser driven deuterium cluster explosions was used to generate a clean source of nearly monoenergetic 2.45 MeV neutrons at a well-defined time. This source can run at 10 Hz and was used to build up a clean pulse-height spectrum on scintillating neutron detectors giving a very accurate calibration for neutron yields at 2.45 MeV

  15. Calibration technique for the neutron surface moisture measurement system

    International Nuclear Information System (INIS)

    Watson, W.T.; Shreve, D.C.

    1996-01-01

    A technique for calibrating the response of a surface neutron moisture measurement probe to material moisture concentration has been devised. Tests to ensure that the probe will function in the expected in-tank operating environment are also outlined

  16. Calibration of a detector for pulsed neutron sources

    International Nuclear Information System (INIS)

    Veeser, L.R.; Hemmendinger, A.; Shunk, E.R.

    1978-02-01

    A plastic scintillator detector for measuring the strength of a pulsed neutron source is described and the problems of calibration and discrimination against x-ray background for both pulsed and steady-state detectors are discussed

  17. On the calibration methods for neutron moisture gauges

    International Nuclear Information System (INIS)

    Apostol, I.

    1975-01-01

    Theoretical and experimental calibration methods for devices using neutron sources to measure the water content in subsurface soil and other samples are investigated. Neutron flux density is evaluated by means of the two and three group diffusion and Fermi age theories. The correction criteria for the calibration curves are presented. The agreement of the theoretical curves with the determined experimental data may be considered as excellent. (author)

  18. The calibration of the MAST neutron yield monitors

    International Nuclear Information System (INIS)

    Stammers, Keith; Loughlin, M.J.

    2006-01-01

    Several neutron detectors have been installed on MAST to monitor the temporal production of neutrons during neutral beam injection. This paper describes the detectors, their calibration and applications of the data. The main neutron diagnostic is a guarded fission chamber, with processing electronics that allow data collection in three modes of operation, and covers the whole range of neutron production rate to be expected from current operations and future upgrades. The scalar mode of operation is calibrated with a 252 Cf source inside the vacuum vessel and then MCNP modelling is used to relate this calibration to an extended plasma source. Plasma neutron data are used to extend the calibration to the Campbell and ion-current modes, with final uncertainties of approximately 8% in each case. Corroborative evidence for the accuracy of the calibration, obtained from neutron activation, indicates that the method is satisfactory. The neutron data are used routinely to keep track of the radio-activation of key components of the MAST tokamak

  19. Neutron calibration sources in the Daya Bay experiment

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J., E-mail: jianglai.liu@sjtu.edu.cn [Department of Physics, Shanghai Jiao Tong University, Shanghai (China); Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Carr, R. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Dwyer, D.A. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Gu, W.Q. [Department of Physics, Shanghai Jiao Tong University, Shanghai (China); Li, G.S., E-mail: lgs1029@sjtu.edu.cn [Department of Physics, Shanghai Jiao Tong University, Shanghai (China); McKeown, R.D. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Department of Physics, College of William and Mary, Williamsburg, VA (United States); Qian, X. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Brookhaven National Laboratory, Upton, NY (United States); Tsang, R.H.M. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Department of Physics and Astronomy, University of Alabama, Tuscaloosa, AL 35487 (United States); Wu, F.F. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Zhang, C. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA (United States); Brookhaven National Laboratory, Upton, NY (United States)

    2015-10-11

    We describe the design and construction of the low rate neutron calibration sources used in the Daya Bay Reactor Anti-neutrino Experiment. Such sources are free of correlated gamma-neutron emission, which is essential in minimizing induced background in the anti-neutrino detector. The design characteristics have been validated in the Daya Bay anti-neutrino detector.

  20. Neutron calibration sources in the Daya Bay experiment

    International Nuclear Information System (INIS)

    Liu, J.; Carr, R.; Dwyer, D.A.; Gu, W.Q.; Li, G.S.; McKeown, R.D.; Qian, X.; Tsang, R.H.M.; Wu, F.F.; Zhang, C.

    2015-01-01

    We describe the design and construction of the low rate neutron calibration sources used in the Daya Bay Reactor Anti-neutrino Experiment. Such sources are free of correlated gamma-neutron emission, which is essential in minimizing induced background in the anti-neutrino detector. The design characteristics have been validated in the Daya Bay anti-neutrino detector

  1. Monoenergetic neutron fields for the calibration of neutron dosemeters at the accelerator facility of the PTB

    International Nuclear Information System (INIS)

    Lesiecki, H.; Cosack, M.; Schoelermann, H.

    1987-01-01

    The present state in the realization of monoenergetic standard neutron fields and the possibility of calibrating neutron dose- and doserate meters at the accelerator facility of the PTB are described. There are excellent conditions for the performance of irradiations in the neutron energy range of 1 keV to 14.8 MeV. (orig.) [de

  2. Tests and calibration of NIF neutron time of flight detectors.

    Science.gov (United States)

    Ali, Z A; Glebov, V Yu; Cruz, M; Duffy, T; Stoeckl, C; Roberts, S; Sangster, T C; Tommasini, R; Throop, A; Moran, M; Dauffy, L; Horsefield, C

    2008-10-01

    The National Ignition Facility (NIF) neutron time of flight (NTOF) diagnostic will measure neutron yield and ion temperature in all NIF campaigns in DD, DT, and THD(*) implosions. The NIF NTOF diagnostic is designed to measure neutron yield from 1x10(9) to 2x10(19). The NTOF consists of several detectors of varying sensitivity located on the NIF at about 5 and 20 m from the target. Production, testing, and calibration of the NIF NTOF detectors have begun at the Laboratory for Laser Energetics (LLE). Operational tests of the NTOF detectors were performed on several facilities including the OMEGA laser at LLE and the Titan laser at Lawrence Livermore National Laboratory. Neutron calibrations were carried out on the OMEGA laser. Results of the NTOF detector tests and calibration will be presented.

  3. Alternative technique to neutron probe calibration in situ

    International Nuclear Information System (INIS)

    Encarnacao, F.; Carneiro, C.; Dall'Olio, A.

    1990-01-01

    An alternative technique of neutron probe calibration in situ was applied for Podzolic soil. Under field condition, the neutron probe calibration was performed using a special arrangement that prevented the lateral movement of water around the access tube of the neutron probe. During the experiments, successive amounts of water were uniformly infiltrated through the soil profile. Two plots were set to study the effect of the plot dimension on the slope of the calibration curve. The results obtained shown that the amounts of water transferred to the soil profile were significantly correlated to the integrals of count ratio along the soil profile on both plots. In consequence, the slope of calibration curve in field condition was determined. (author)

  4. Calculations to support JET neutron yield calibration: Modelling of neutron emission from a compact DT neutron generator

    Science.gov (United States)

    Čufar, Aljaž; Batistoni, Paola; Conroy, Sean; Ghani, Zamir; Lengar, Igor; Milocco, Alberto; Packer, Lee; Pillon, Mario; Popovichev, Sergey; Snoj, Luka; JET Contributors

    2017-03-01

    At the Joint European Torus (JET) the ex-vessel fission chambers and in-vessel activation detectors are used as the neutron production rate and neutron yield monitors respectively. In order to ensure that these detectors produce accurate measurements they need to be experimentally calibrated. A new calibration of neutron detectors to 14 MeV neutrons, resulting from deuterium-tritium (DT) plasmas, is planned at JET using a compact accelerator based neutron generator (NG) in which a D/T beam impinges on a solid target containing T/D, producing neutrons by DT fusion reactions. This paper presents the analysis that was performed to model the neutron source characteristics in terms of energy spectrum, angle-energy distribution and the effect of the neutron generator geometry. Different codes capable of simulating the accelerator based DT neutron sources are compared and sensitivities to uncertainties in the generator's internal structure analysed. The analysis was performed to support preparation to the experimental measurements performed to characterize the NG as a calibration source. Further extensive neutronics analyses, performed with this model of the NG, will be needed to support the neutron calibration experiments and take into account various differences between the calibration experiment and experiments using the plasma as a source of neutrons.

  5. Calculations to support JET neutron yield calibration: Modelling of neutron emission from a compact DT neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Čufar, Aljaž, E-mail: aljaz.cufar@ijs.si [Reactor Physics Department, Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Batistoni, Paola [ENEA, Department of Fusion and Nuclear Safety Technology, I-00044 Frascati, Rome (Italy); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Conroy, Sean [Uppsala University, Department of Physics and Astronomy, PO Box 516, SE-75120 Uppsala (Sweden); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Ghani, Zamir [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Lengar, Igor [Reactor Physics Department, Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Milocco, Alberto; Packer, Lee [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Pillon, Mario [ENEA, Department of Fusion and Nuclear Safety Technology, I-00044 Frascati, Rome (Italy); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Popovichev, Sergey [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Snoj, Luka [Reactor Physics Department, Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)

    2017-03-01

    At the Joint European Torus (JET) the ex-vessel fission chambers and in-vessel activation detectors are used as the neutron production rate and neutron yield monitors respectively. In order to ensure that these detectors produce accurate measurements they need to be experimentally calibrated. A new calibration of neutron detectors to 14 MeV neutrons, resulting from deuterium–tritium (DT) plasmas, is planned at JET using a compact accelerator based neutron generator (NG) in which a D/T beam impinges on a solid target containing T/D, producing neutrons by DT fusion reactions. This paper presents the analysis that was performed to model the neutron source characteristics in terms of energy spectrum, angle–energy distribution and the effect of the neutron generator geometry. Different codes capable of simulating the accelerator based DT neutron sources are compared and sensitivities to uncertainties in the generator's internal structure analysed. The analysis was performed to support preparation to the experimental measurements performed to characterize the NG as a calibration source. Further extensive neutronics analyses, performed with this model of the NG, will be needed to support the neutron calibration experiments and take into account various differences between the calibration experiment and experiments using the plasma as a source of neutrons.

  6. Calibration issues of the TFTR multichannel neutron collimator

    International Nuclear Information System (INIS)

    Goeler, S. von; Johnson, L.C.; Bitter, M.; Efthimion, P.C.; Roquemore, A.L.

    1996-01-01

    The calibration procedures for the detectors in the Neutron Collimator are reviewed. The absolute calibration was performed for the NE451 detectors, in situ, by moving a DT neutron generator in the TFTR vacuum vessel across each sight line. This calibration was transferred to other detectors in the same channel. Four new sight lines have been installed at a different toroidal location, which view the plasma through the vacuum vessel port cover rather than through thinned windows. The new detectors are cross-calibrated to the NE451 detectors with a jog shot procedure, where the plasma is quickly shifted in major radius over a distance of 30 cm. The jog shot procedure shows that scattered neutrons account approximately for 30% of the signal of the new central channels. The neutron source strength from the collimator agrees within 10% with the source strength from global neutron monitors in the TFTR test cell. Detector non-linearity is discussed. Another special issue is the behavior of the detectors during T-puffs, where the DD/DT neutron ratio changes rapidly

  7. Neutron spectrum survey around the cyclotron of IEN/Brazilian CNEN: calibration of neutron personnel dosemeter

    International Nuclear Information System (INIS)

    Fajardo, P.W.

    1991-01-01

    The albedo neutron dosimeter is calibrated directly at the work place due to its high energy dependence. This thesis deals with the study, analysis and application of neutron measurement techniques in order to obtain information about the neutron spectrum and neutron dose equivalent at several representative working places of the cyclotron laboratory of the Nuclear Engineering Institute (IEN). These data are employed mainly in the calibration of the brazilian albedo neutron dosimeter. Bonner spheres and foil activation were used in neutron spectra measurements and the neutron dose equivalents were measured with the single sphere albedo technique. BF 3 and 3 He proportional detectors and 6 LiI scintillation detector were also used in these measurements. The single sphere technique turned out to be more appropriate for neutron dosimetry for calibrating the albedo dosimeter in the varying fields of the cyclotron. Calibration the albedo dosimeter in the varying fields of the cyclotron. Calibration factors were found for routine applications, when the workers are protected by shielding and for radiological accident applications, in the case that a worker is exposed inside the cyclotron room. In all situations the performance of the brazilian albedo dosimeter is compared with that of the german albedo dosimeters. (author)

  8. Calibrating the neutron moisture meter: Precision and economy

    International Nuclear Information System (INIS)

    Akhter, J.; Waheed, R.A.; Hignett, C.T.; Greacen, E.L.

    2000-01-01

    Established laboratory and field calibration procedures for the neutron moisture meter are demonstrated on a uniform soil and alternative, low cost procedures on a duplex, less uniform soil. The effect of field variability on the calibration methodology is discussed with the aim of optimising calibration reliability at minimal cost. The difference between calibration for a soil material, or for a field (a range of soil materials) is considered. In particular, calibration for the estimation of water content change is shown to be a different problem from calibration for the estimation of water content in a variable field. Techniques aimed at detecting field variability problems during calibration are suggested, and methods for optimising the results for the intended use of the instrument are outlined. Pairing of calibration tubes, alternative methods of analysis of calibration data, and use of other information from the field to measure its variability, can improve the precision of calibration procedures to the point where minimal calibration effort, with careful analysis, can provide reliable results. (author)

  9. Site-specific calibration of the Hanford personnel neutron dosimeter

    International Nuclear Information System (INIS)

    Endres, A.W.; Brackenbush, L.W.; Baumgartner, W.V.; Rathbone, B.A.

    1994-10-01

    A new personnel dosimetry system, employing a standard Hanford thermoluminescent dosimeter (TLD) and a combination dosimeter with both CR-39 nuclear track and TLD-albedo elements, is being implemented at Hanford. Measurements were made in workplace environments in order to verify the accuracy of the system and establish site-specific factors to account for the differences in dosimeter response between the workplace and calibration laboratory. Neutron measurements were performed using sources at Hanford's Plutonium Finishing Plant under high-scatter conditions to calibrate the new neutron dosimeter design to site-specific neutron spectra. The dosimeter was also calibrated using bare and moderated 252 Cf sources under low-scatter conditions available in the Hanford Calibration Laboratory. Dose equivalent rates in the workplace were calculated from spectrometer measurements using tissue equivalent proportional counter (TEPC) and multisphere spectrometers. The accuracy of the spectrometers was verified by measurements on neutron sources with calibrations directly traceable to the National Institute of Standards and Technology (NIST)

  10. Neutron field features in a calibration hall

    International Nuclear Information System (INIS)

    Vega C, H.R.; Gallego, E.; Lorente, A.

    2004-01-01

    A new source facility ( 241 Am-Be) has been installed in a large size bunker-type room. To characterize the neutron fields in the facility, detailed calculations have been made with MCNP-4C, showing the different components of the neutron radiation reaching the reference points (direct, in scattered, backscattered). The contribution from neutrons scattered in the walls to the total ambient dose equivalent remains reasonably low ( 6 LiI(Eu) scintillator (0.4 cm 0 x 0.4 cm), UTA4 response matrix and BUNKIUT unfolding code. The calculated and experimentally obtained spectra are compared, with small differences found in the epithermal and thermal region, attributable to the concrete composition used in the calculations. The H*(10) rate has been determined from the spectra, and then compared to the reading of an active dosemeter (LB 6411), with differences found lower than 8%. (Author)

  11. Characteristics of thermal neutron calibration fields using a graphite pile

    International Nuclear Information System (INIS)

    Uchita, Yoshiaki; Saegusa, Jun; Kajimoto, Yoichi; Tanimura, Yoshihiko; Shimizu, Shigeru; Yoshizawa, Michio

    2005-03-01

    The Facility of Radiation Standards of Japan Atomic Energy Research Institute is equipped with thermal neutron fields for calibrating area and personal neutron dosemeters. The fields use moderated neutrons leaked from a graphite pile in which radionuclide sources are placed. In January 2003, we have renewed the pile with some modifications in its size. In accordance with the renewal, we measured and calculated thermal neutron fluence rates, neutron energy distributions and angular distributions of the fields. The thermal neutron fluence rates of the ''inside-pile fields'' and the outside-pile fields'' were determined by the gold foil activation method. The neutron energy distributions of the outside-pile fields were also measured with the Bonner multi-sphere spectrometer system. The contributions of epithermal and fast neutrons to the total dose-equivalents were 9% in the southern outside-pile field and 12% in the western outside-pile field. The personal dose-equivalents, H p,slab (10, α), in the outside-pile fields are evaluated by considering the calculated angular distributions of incoming neutrons. The H p,slab (10, α) was found to be about 40% higher than the value in assuming the unidirectional neutron between the pile and the test point. (author)

  12. Neutron dosemeter responses in workplace fields and the implications of using realistic neutron calibration fields

    International Nuclear Information System (INIS)

    Thomas, D.J.; Horwood, N.; Taylor, G.C.

    1999-01-01

    The use of realistic neutron calibration fields to overcome some of the problems associated with the response functions of presently available dosemeters, both area survey instruments and personal dosemeters, has been investigated. Realistic calibration fields have spectra which, compared to conventional radionuclide source based calibration fields, more closely match those of the workplace fields in which dosemeters are used. Monte Carlo simulations were performed to identify laboratory systems which would produce appropriate workplace-like calibration fields. A detailed analysis was then undertaken of the predicted under- and over-responses of dosemeters in a wide selection of measured workplace field spectra assuming calibration in a selection of calibration fields. These included both conventional radionuclide source calibration fields, and also several proposed realistic calibration fields. The present state of the art for dosemeter performance, and the possibilities of improving accuracy by using realistic calibration fields are both presented. (author)

  13. Preliminary calibration of the ACP safeguards neutron counter

    Science.gov (United States)

    Lee, T. H.; Kim, H. D.; Yoon, J. S.; Lee, S. Y.; Swinhoe, M.; Menlove, H. O.

    2007-10-01

    The Advanced Spent Fuel Conditioning Process (ACP), a kind of pyroprocess, has been developed at the Korea Atomic Energy Research Institute (KAERI). Since there is no IAEA safeguards criteria for this process, KAERI has developed a neutron coincidence counter to make it possible to perform a material control and accounting (MC&A) for its ACP materials for the purpose of a transparency in the peaceful uses of nuclear materials at KAERI. The test results of the ACP Safeguards Neutron Counter (ASNC) show a satisfactory performance for the Doubles count measurement with a low measurement error for its cylindrical sample cavity. The neutron detection efficiency is about 21% with an error of ±1.32% along the axial direction of the cavity. Using two 252Cf neutron sources, we obtained various parameters for the Singles and Doubles rates for the ASNC. The Singles, Doubles, and Triples rates for a 252Cf point source were obtained by using the MCNPX code and the results for the ft8 cap multiplicity tally option with the values of ɛ, fd, and ft measured with a strong source most closely match the measurement results to within a 1% error. A preliminary calibration curve for the ASNC was generated by using the point model equation relationship between 244Cm and 252Cf and the calibration coefficient for the non-multiplying sample is 2.78×10 5 (Doubles counts/s/g 244Cm). The preliminary calibration curves for the ACP samples were also obtained by using an MCNPX simulation. A neutron multiplication influence on an increase of the Doubles rate for a metal ingot and UO2 powder is clearly observed. These calibration curves will be modified and complemented, when hot calibration samples become available. To verify the validity of this calibration curve, a measurement of spent fuel standards for a known 244Cm mass will be performed in the near future.

  14. Calibration of neutron yield activation measurements at JET using MCNP and furnace neutron transport codes

    International Nuclear Information System (INIS)

    Pillon, M.; Martone, M.; Verschuur, K.A.; Jarvis, O.N.; Kaellne, J.

    1989-01-01

    Neutron transport calculations have been performed using fluence ray tracing (FURNACE code) and Monte Carlo particle trajectory sampling methods (MCNP code) in order to determine the neutron fluence and energy distributions at different locations in the JET tokamak. These calculations were used to calibrate the activation measurements used in the determination of the absolute fusion neutron yields from the JET plasma. We present here the neutron activation response coefficients calculated for three different materials. Comparison of the MCNP and FURNACE results helps identify the sources of error in these neutron transport calculations. The accuracy of these calculations was tested by comparing the total 2.5 MeV neutron yields derived from the activation measurements with those obtained with calibrated fission chambers; agreement at the ±15% level was demonstrate. (orig.)

  15. In situ neutron moisture meter calibration in lateritic soils

    International Nuclear Information System (INIS)

    Ruprecht, J.K.; Schofield, N.J.

    1990-01-01

    An in situ calibration procedure for complex lateritic soils of the jarrah forest of Western Australia is described. The calibration is based on non-destructive sampling of each access tube and on a regression of change in water content on change in neutron count ratio at 'wet' and 'dry' times of the year. Calibration equations with adequate precision were produced. However, there were high residual errors in the calibration equations which were due to a number of factors including soil water variability, the presence of a duricrust layer, soil sampling of gravelly soils and the variability of the cement slurry annulus surrounding each access tube. The calibration equations derived did not compare well with those from other studies in south-west Western Australia, but there was reasonable agreement with the general equations obtained by the Institute of Hydrology, U.K. 15 refs., 6 figs., 2 tabs

  16. Calibration of the delayed-gamma neutron activation facility

    International Nuclear Information System (INIS)

    Ma, R.; Zhao, X.; Rarback, H.M.; Yasumura, S.; Dilmanian, F.A.; Moore, R.I.; Lo Monte, A.F.; Vodopia, K.A.; Liu, H.B.; Economos, C.D.; Nelson, M.E.; Aloia, J.F.; Vaswani, A.N.; Weber, D.A.; Pierson, R.N. Jr.; Joel, D.D.

    1996-01-01

    The delayed-gamma neutron activation facility at Brookhaven National Laboratory was originally calibrated using an anthropomorphic hollow phantom filled with solutions containing predetermined amounts of Ca. However, 99% of the total Ca in the human body is not homogeneously distributed but contained within the skeleton. Recently, an artificial skeleton was designed, constructed, and placed in a bottle phantom to better represent the Ca distribution in the human body. Neutron activation measurements of an anthropomorphic and a bottle (with no skeleton) phantom demonstrate that the difference in size and shape between the two phantoms changes the total body calcium results by less than 1%. To test the artificial skeleton, two small polyethylene jerry-can phantoms were made, one with a femur from a cadaver and one with an artificial bone in exactly the same geometry. The femur was ashed following the neutron activation measurements for chemical analysis of Ca. Results indicate that the artificial bone closely simulates the real bone in neutron activation analysis and provides accurate calibration for Ca measurements. Therefore, the calibration of the delayed-gamma neutron activation system is now based on the new bottle phantom containing an artificial skeleton. This change has improved the accuracy of measurement for total body calcium. Also, the simple geometry of this phantom and the artificial skeleton allows us to simulate the neutron activation process using a Monte Carlo code, which enables us to calibrate the system for human subjects larger and smaller than the phantoms used as standards. copyright 1996 American Association of Physicists in Medicine

  17. Calibration of quantitative neutron radiography method for moisture measurement

    International Nuclear Information System (INIS)

    Nemec, T.; Jeraj, R.

    1999-01-01

    Quantitative measurements of moisture and hydrogenous matter in building materials by neutron radiography (NR) are regularly performed at TRIGA Mark II research of 'Jozef Stefan' Institute in Ljubljana. Calibration of quantitative method is performed using standard brick samples with known moisture content and also with a secondary standard, plexiglas step wedge. In general, the contribution of scattered neutrons to the neutron image is not determined explicitly what introduces an error to the measured signal. Influence of scattered neutrons is significant in regions with high gradients of moisture concentrations, where the build up of scattered neutrons causes distortion of the moisture concentration profile. In this paper detailed analysis of validity of our calibration method for different geometrical parameters is presented. The error in the measured hydrogen concentration is evaluated by an experiment and compared with results obtained by Monte Carlo calculation with computer code MCNP 4B. Optimal conditions are determined for quantitative moisture measurements in order to minimize the error due to scattered neutrons. The method is tested on concrete samples with high moisture content.(author)

  18. Calibration

    International Nuclear Information System (INIS)

    Greacen, E.L.; Correll, R.L.; Cunningham, R.B.; Johns, G.G.; Nicolls, K.D.

    1981-01-01

    Procedures common to different methods of calibration of neutron moisture meters are outlined and laboratory and field calibration methods compared. Gross errors which arise from faulty calibration techniques are described. The count rate can be affected by the dry bulk density of the soil, the volumetric content of constitutional hydrogen and other chemical components of the soil and soil solution. Calibration is further complicated by the fact that the neutron meter responds more strongly to the soil properties close to the detector and source. The differences in slope of calibration curves for different soils can be as much as 40%

  19. Comparison of methods of calibration of a neutron probe by gravimetry or neutron-capture model

    International Nuclear Information System (INIS)

    Vachaud, G.; Royer, J.M.; Cooper, J.D.

    1977-01-01

    This paper presents a systematic analysis of two methods used for determining calibration curves of neutron probes. The uncertainties resulting from the use of the gravimetric method, with a linear correlation between count rates and water content of soil samples, are considered first. Particular care is given to the determination of errors in the values of water content and count rates, and to the difficulties arising from the choice of the correlation technique. The neutron-calibration curve of the soil was also obtained with a technique based on the determination of neutron thermal adsorption and diffusion constants. The importance of errors associated with this method is also analyzed. Different field examples are then presented. It appears that the neutron-capture technique should be particularly well suited for determining the calibration curve of clay soils or heterogeneous materials for which the gravimetric calibration technique cannot be applied with confidence. On the other hand, it is also shown that for a soil with a very well-defined gravimetric calibration curve, the neutron-capture technique gives results still at least as good as with the former method

  20. New thermal neutron calibration channel at LNMRI/IRD

    Energy Technology Data Exchange (ETDEWEB)

    Astuto, A.; Lopes, R.T., E-mail: achillesbr@gmail.com [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil); Patrao, K.C.S.; Fonseca, E.S.; Pereira, W.W. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ/LNMRI), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes

    2015-07-01

    A new standard thermal neutron flux unit was designed in the National Ionizing Radiation Metrology Laboratory (LNMRI) for calibration of neutron detectors. Fluence is achieved by moderation of four {sup 241}Am-Be sources with 596 GBq each, in a facility built with graphite and paraffin blocks. The study was divided into two stages. First, simulations were performed using MCNPX code in different geometric arrangements, seeking the best performance in terms of fluence and their uncertainties. Last, the system was assembled based on the results obtained on the simulations. The simulation results indicate quasi-homogeneous fluence (less than 1%) in the central chamber. (author)

  1. New thermal neutron calibration channel at LNMRI/IRD

    International Nuclear Information System (INIS)

    Astuto, A.; Lopes, R.T.; Patrao, K.C.S.; Fonseca, E.S.; Pereira, W.W.

    2015-01-01

    A new standard thermal neutron flux unit was designed in the National Ionizing Radiation Metrology Laboratory (LNMRI) for calibration of neutron detectors. Fluence is achieved by moderation of four 241 Am-Be sources with 596 GBq each, in a facility built with graphite and paraffin blocks. The study was divided into two stages. First, simulations were performed using MCNPX code in different geometric arrangements, seeking the best performance in terms of fluence and their uncertainties. Last, the system was assembled based on the results obtained on the simulations. The simulation results indicate quasi-homogeneous fluence (less than 1%) in the central chamber. (author)

  2. Thermal neutron calibration channel at LNMRI/IRD

    International Nuclear Information System (INIS)

    Astuto, A.; Salgado, A.P.; Lopes, R.T.; Leite, S.P.; Patrao, K.C.S.; Fonseca, E.S.; Pereira, W.W.

    2014-01-01

    The Brazilian Metrology Laboratory of Ionizing Radiations (LNMRI) standard thermal neutron flux facility was designed to provide uniform neutron fluence for calibration of small neutron detectors and individual dosemeters. This fluence is obtained by neutron moderation from four 241 Am-Be sources, each with 596 GBq, in a facility built with blocks of graphite/paraffin compound and high-purity carbon graphite. This study was carried out in two steps. In the first step, simulations using the MCNPX code on different geometric arrangements of moderator materials and neutron sources were performed. The quality of the resulting neutron fluence in terms of spectrum, cadmium ratio and gamma-neutron ratio was evaluated. In the second step, the system was assembled based on the results obtained on the simulations, and new measurements are being made. These measurements will validate the system, and other intercomparisons will ensure traceability to the International System of Units. The pile construction form using blocks allows distinct arrangements for new studies and possibilities of other LNMRI reference fields. The results can be predicted by the simulation used in this work. Different number of each type of blocks and sources can be used. The main difference observed between the final measurement and simulation results might be due to the difference in composition of paraffin blocks used in assembling the pile. In order to confirm the thermal neutron field and fluence rate in the central chamber (inside the channel) that will be used to irradiate small neutron detectors, it is necessary to use another quantification method such as the gold foils activation with measurement traceability. It will be performed in a future stage. (authors)

  3. Test of an albedo neutron dosimetry system: TLD calibration and readout procedure, neutron calibration, dosimetry properties, routine application

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1988-03-01

    The two-component albedo dosemeter in use consists of an universal boron-loaded plastic encapsulation, the beta and albedo neutron windows of which are adopted to the corresponding TLD system of the manufacturers Alnor, Harshaw, Panasonic and Vinten. Beside the TLD detectors the capsule may contain also track etch detectors. Within a BMU project the system was investigated by four governmental measurement services in the FRG with respect to its qualification for personnel monitoring with emphasis in the readout and calibration procedures for the TLD system, the evaluation technique for the estimation of the photon and neutron dose equivalent in routine monitoring and the calibration of the personnel dosemeter in stray neutron fields. The test has shown the readiness of the system to act in the application areas of nuclear power reactors and linacs behind heavy shieldings, in the fuel element cycle, use of fissile materials, criticality, use of radionuclide sources, high energy particle accelerators. The uncertainty due to energy dependence was found to be within a factor of 2 for a single application area. In the case of irradiations from the front half space the dose equivalent H'(10) is indicated sufficiently independent of the direction of the radiation incidence. After completion of the test the albedo dosemeter became the official neutron personnel dosemeter in the FRG. It allows the separate estimation of the dose equivalent of hard beta radiation, photon radiation and neutrons. (orig./HP) [de

  4. Calibration of a NE213 detector for neutron spectroscopy

    International Nuclear Information System (INIS)

    Blazquez Martinez, J.; Butragueno Casado, J. L.

    1974-01-01

    This work describes the experimental way followed for getting the calibration of a NE213 detector with a beam of neutrons from the J.E.N. 2 MeV Van de Graaff and using at once pulse shape discrimination. Detector has been used for measuring the spectrum of the fast reactor CORAL-1. There is also included an experimental method in order to get with precision where the Compton edge is placed on the electron spectrum. (Author) 9 refs

  5. Soil texture and depth influence on the neutron probe calibration

    International Nuclear Information System (INIS)

    Santos, Reginaldo Ferreira; Carlesso, Reimar

    1998-01-01

    The neutron probe is an equipment used on determination of the soil water content, based on the fast neutron attenuation. Therefore, there is a calibration need in the field and, consequently, to verify the soil texture and depth influence for to determining the calibration curves in relation to the water content. The study was developed at Santa Maria's Federal University in a lisimeter group, protected from the rains with transparent plastic. There different soil textures, three depths (10, 30 and 50 cm from the soil surface) and four replicates were used. Linear regression equations between neutron counts and soil water contents were made. The results showed that there was interference of the texture and depth of the soil, analyzed jointly, on the calibration curves, and the observed and estimated values varied form o,02 to 0,06 cm3/cm3 of the soil water content and the correlation coefficients were 0,86 0,95 and 0,89 for clayray, franc-silt-clayey and franc-sandy, respectively. For soil texture and depth, analyzed separately, the differences among the values observed in the field and the estimated ones, varied from 0,0 to 0,02 cm3/cm3 soil water content and presented correlation coefficients between 0,97 and 1,0. (author)

  6. Calibration procedure and wavelength correction for neutron depolarization experiments

    International Nuclear Information System (INIS)

    Roest, W.; Rekveldt, M.T.

    1992-01-01

    The neutron polarimeter, for which an extended calibration procedure is described here, enables one to investigate magnetic properties of materials. Such an investigation is carried out by offering a polarized neutron beam in the x-, y- and z-direction successively and, after transmission through the sample, by analysing the polarization in all three directions. The result is a 3x3 depolarization matrix. After the polarizer, the neutron beam has a polarization along the z-direction. Two coil systems creating a magnetic field in the yz-plane perpendicular to the beam direction provide the possibility to direct the polarization in the x-, y- and z-direction by means of Larmor precession of the polarization in these fields. New research areas, where small depolarization effects together with considerable polarization rotation are measured, have caused a need for more accuracy in, and better knowledge of the calibration of the polarimeter. The calibration procedure use up to now and the improvements made on it are described. (orig.)

  7. A neutron calibration technique for detectors with low neutron/high photon sensitivity

    International Nuclear Information System (INIS)

    Jahr, R.; Guldbakke, S.; Cosack, M.; Dietze, G.; Klein, H.

    1978-03-01

    The neutron response of a detector with low neutron-/high photon sensitivity is given by the difference of two terms: the response to the mixed neutron-photon field, measured directly, and the response to the photons, deduced from additional measurements with a photon spectrometer. The technique is particularly suited for use in connection with targets which consist of a thick backing and thin layer of neutron producing material such as T, D, Li nuclei. Then the photon component of the mixed field is very nearly the same as the pure photon field from a 'phantom target', being identical with the neutron producing target except for the missing neutron producing material. Using this technique in connection with a T target (Ti-T-layer on silver backing) and the corresponding phantom target (Ti-layer on silver backing), a GM counter was calibrated at a neutron energy of 2.5 MeV. Possibilities are discussed to subsequently calibrate the GM counter at other neutron energies without the use of the photon spectrometer. (orig./HP) [de

  8. Calibration of a spectrometry multisphere system for neutron fields

    International Nuclear Information System (INIS)

    Carelli, Jorge L.; Cruzate, Juan A.; Papadopulos, Susana B.; Gregori, Beatriz N.; Ciocci Brazzano, Ligia

    2005-01-01

    In this work it is presented the calibration of the neutrons spectrometric system of the Nuclear Regulatory Authority (ARN) in the Institut de Protection et Sure te Nucleaires (Ipn), Labourite dadaist et de Recherche s en Dosimetric Extern e, Cadarache, France. The multisphere system is composed of 9 polyethylene spheres of high density, with a gaseous detector of 3 He and associate electronics. The matrix of energy response to the system neutrons was obtained applying the MCNPX code for the range of energies between thermal and 100 MeV with cross sections taken from library ENDF/B-VI. The neutron spectra of the multisphere system were obtained applying the deconvolution code LOUHI82. The relationship between the theoretical responses and the experiences obtained with the AmBe and 252 Cf sources are also presented in this work [es

  9. Calibration experiments of neutron source identification and detection in soil

    International Nuclear Information System (INIS)

    Gorin, N. V.; Lipilina, E. N.; Rukavishnikov, G. V.; Shmakov, D. V.; Ulyanov, A. I.

    2007-01-01

    In the course of detection of fissile materials in soil, series of calibration experiments were carried out on in laboratory conditions on an experimental installation, presenting a mock-up of an endless soil with various heterogeneous bodies in it, fissile material, measuring boreholes. A design of detecting device, methods of neutrons detection are described. Conditions of neutron background measuring are given. Soil density, humidity, chemical composition of soil was measured. Sensitivity of methods of fissile materials detection and identification in soil was estimated in the calibration experiments. Minimal detectable activity and the distance at which it can be detected were defined. Characteristics of neutron radiation in a borehole mock-up were measured; dependences of method sensitivities from water content in soil, source-detector distance and presence of heterogeneous bodies were examined. Possibility of direction detection to a fissile material as neutron source from a borehole using a collimator is shown. Identification of fissile material was carried out by measuring the gamma-spectrum. Mathematical modeling was carried out using the PRIZMA code (Developed in RFNC-VNIITF) and MCNP code (Developed in LANL). Good correlation of calculational and experimental values was shown. The methodic were shown to be applicable in the field conditions

  10. A review of neutron scattering correction for the calibration of neutron survey meters using the shadow cone method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang In; Kim, Bong Hwan; Kim, Jang Lyul; Lee, Jung Il [Health Physics Team, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a {sup 252}Californium ({sup 252}Cf) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1 - 9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered.

  11. A review of neutron scattering correction for the calibration of neutron survey meters using the shadow cone method

    International Nuclear Information System (INIS)

    Kim, Sang In; Kim, Bong Hwan; Kim, Jang Lyul; Lee, Jung Il

    2015-01-01

    The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a 252 Californium ( 252 Cf) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1 - 9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered

  12. Calibration of neutrons monitors with moderators and application in the calibration factors of albedo dosemeters

    International Nuclear Information System (INIS)

    Schuch, L.A.

    1978-11-01

    The calibration factors and the reproducibility of an Albedo Dosimeter designed for personal neutron monitoring were determined. These factor were obtained simulating the dosimeter reading and the equivalent dose in the locality by a convenient combination of responses of the Bonner Sphere Spectrometer. The results obtained in the simulation were verified experimentally for different spectra employing the Am-Be, bare 252 Cf source and 253 Cf source with graphite sields of varying thickness. Different standards were used in the procedures necessary for the determination of the calibration factors. An Am-Be neutron source, standardized by the activation of a manganese sulphate bath was used as a primary standard. As a secondary standard, for the measurement of the neutron fluence, a De Pangher Long Counter was used and the scattering effects were determined using the shadow cone method. The other monitors such as the Rem-Counter and the Bonner Sphere Spectrometer were also calibrated with reference to the secondary standard with a view to comparing the results obtained with those furnished by the Albedo Dosimeter. (Author) [pt

  13. Definition and production of calibration standard neutron sources for radiation protection device calibration

    International Nuclear Information System (INIS)

    De Matos, E.

    1987-01-01

    To improve the characterization of radioprotection devices performances, it would be advisable to calibrate these devices in neutron spectra which are nearly like those met in practice (nuclear reactors, plutonium technology laboratories...). The purpose of this work is, in a first time, to choose the nature and the dimensions of the different shields used to achieve broad typical neutron spectra extending to lower energies from a 14.8 MeV neutron beam. The second step is the evaluation of spectral distribution and calculation of associated dosimetric quantities. For that, several spectrometric techniques are employed: on one hand, activation detectors and Bonner spheres method named rough spectrometry; on the other hand, an accurate spectrometry which uses recoil proton counters. The dosimetric quantities, especially the value of kerma deduced from these spectra must be in good agreement with those measured with a tissue equivalent ionization chamber [fr

  14. Calibration of a special neutron dosemeter based on solid-state track detectors and fission radiators in various neutron fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Krusche, M.; Schuricht, V.

    1980-01-01

    The calibration of a personnel neutron dosemeter in different neutron fields is described. The badge-like dosemeter contains 5 detectors: polycarbonate foil (10 μm, Makrofol KG), 232 Th, natural uranium, natural uranium with boron, and natural uranium with cadmium. Detector sensitivity and calibration factors have been calculated and measured in radiation fields of 252 Cf fission neutrons, WWR-S reactor neutrons with and without Cd and Fe shielding, 3-MeV (d,t) generator neutrons, and 238 PuBe neutrons. Measurement range and achievable accuracy are discussed from the point of view of applying the dosemeter in routine and emergency uses

  15. Calibration and automatic counting in a neutrons dosimeter

    International Nuclear Information System (INIS)

    Tavera-Davila, M.L.

    1991-01-01

    Over the past decade, the majority of improvements in spectrometry have not come from improved detectors but from better computing facilities, in Folding codes, and nuclear data. However several types of passive neutron detectors have the potential for development into crude, low resolution spectrometers, to be worn by individuals, making them attractive to be subject of more time of investigation. This thesis contributes to the understanding of the properties of solid state nuclear tracks (SSNTD) in order to use them in neutron dosimetry and spectrometry. In the first chapter the basic principles on neutron interaction with matter and some relevant considerations about detection and dosimetry are presented. The third chapter deals with detection properties of solid state nuclear track detectors (SSNTD). Calibration methods are presented for three different applications, detection of heavy ions, radon and neutrons. In chapter 4, some equations are derived which predict the whole efficiency formation of thin plastic detectors as a function of range, angle, and type of inciding particle as well as residual thickness. Using experimental data on proton registration properties in thin plastic detectors and the former derived equations, mathematical expressions are developed to predict the sparking counting efficiency for recoll protons and trions produced by neutrons in SSNTD. Chapter five deals with the comparison between experimental results and theoretical results of chapter 4. In chapter 6 experimental optimum parameters for electrochemical etching of thin plastic detectors are presented. The electrochemical etching efficiency is compared with the spark countering efficiency obtained in chapter 5. In chapter 7, general comments on applications to neutron dosimetry are presented. (Author)

  16. Development of moderated neutron calibration fields simulating workplaces of MOX fuel facilities

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Takada, Chie

    2005-01-01

    It is important for the MOX fuel facilities to control neutrons produced by the spontaneous fission of plutonium isotopes and those from (α,n) reactions between 18 O and α particles emitted by 238 Pu. Neutron dose meters should be calibrated for measuring these neutrons. We have developed moderated-neutron calibration fields employing a 252 Cf neutron source and moderators mainly for the characteristics evaluation and the calibration of neutron detectors used in MOX fuel facilities. Neutron energy spectrum can be adjusted by changing the position of the 252 Cf neutron source and combining different moderators to simulate the neutron field of the MOX fuel facility. This performance is realized owing to using an existing neutron irradiation room. (K. Yoshida)

  17. Design, construction, and calibration of a nonfocusing neutron spectrometer

    International Nuclear Information System (INIS)

    Storey, W.

    1974-12-01

    A fourteen-channel time-resolved neutron spectrometer with associated Faraday cup has been designed and constructed for use in the field. A neutron energy range of 9.5 to 15 MeV is covered. Both instruments detect protons elastically scattered from a thin hydrogenous foil in interaction with the neutron beam, with magnetic analysis of the protons by the spectrometer. The design requirements of small size and weight and 0.6 to 0.7 MeV resolution have been met. Following a description of the instrument and of its geometry, there is a detailed presentation of the design and construction of the instrument. The section on instrument performance is concerned with the comparison between predicted performance based upon computation, in which the magnet is of primary interest, and upon measured performance based upon a calibration experiment, which is given a general description in Appendix A. Software used mainly for signal prediction and unfolding, for both the neutron spectrometer and Faraday cup, is described

  18. Method of energy calibration of the TANSY neutron detectors

    International Nuclear Information System (INIS)

    Hoek, M.; Drozdowicz, K.; Aronsson, D.

    1990-03-01

    A method to calibrate an array of scintillation neutron detectors, using a γ source, is presented. The count rate is measured as a function of high voltage at a given discrimination level. The obtained distribution is differentiated and a maximum value is determined which corresponds to the voltage at which the gamma peak passes through the discrimination level. By repeating the measurement at different discrimination levels the experimental dependence between the discrimination level and the high voltage is found as a straight line in a log-log diagram. Two calibration parameter for each detector are determined from a fit of these straight lines. A recalculation from the energy of the used γ source to any other energy is then possible and the obtained relation can be used to calculate discrimination levels and high voltages for each detector. Verification procedures are described. (authors)

  19. Dose Calibration of the ISS-RAD Fast Neutron Detector

    Science.gov (United States)

    Zeitlin, C.

    2015-01-01

    The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of ?10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

  20. Total body neutron activation analysis of calcium: calibration and normalisation

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, N S.J.; Eastell, R; Ferrington, C M; Simpson, J D; Strong, J A [Western General Hospital, Edinburgh (UK); Smith, M A; Tothill, P [Royal Infirmary, Edinburgh (UK)

    1982-05-01

    An irradiation system has been designed, using a neutron beam from a cyclotron, which optimises the uniformity of activation of calcium. Induced activity is measured in a scanning, shadow-shield whole-body counter. Calibration has been effected and reproducibility assessed with three different types of phantom. Corrections were derived for variations in body height, depth and fat thickness. The coefficient of variation for repeated measurements of an anthropomorphic phantom was 1.8% for an absorbed dose equivalent of 13 mSv (1.3 rem). Measurements of total body calcium in 40 normal adults were used to derive normalisation factors which predict the normal calcium in a subject of given size and age. The coefficient of variation of normalised calcium was 6.2% in men and 6.6% in women, with the demonstration of an annual loss of 1.5% after the menopause. The narrow range should make single measurements useful for diagnostic purposes.

  1. Calibration of a TLD system to estimate personal doses in fields of gamma-neutrons radiation

    International Nuclear Information System (INIS)

    Villegas, E.N.; Somarriba, S.I.

    2016-01-01

    Currently Nicaragua has no personal neutron dosimetry system. The calibration of a batch of albedo neutron dosimeters consisting of two pairs of "6LiF and "7LiF (Mg, Ti) detectors was done. The dosimeter and reader sensitivities were obtained using a "1"3"7Cs source, and a neutron calibration factor was found with a "2"4"1AmBe source. Reproducibility and homogeneity tests were performed, and the detection limit of the system was determined. This calibration will allow the beginning of neutron personal monitoring in the country. (author)

  2. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  3. Calibration Of A 14 MeV Neutron Generator With Reference To NBS-1

    International Nuclear Information System (INIS)

    Heimbach, Craig R.

    2011-01-01

    NBS-1 is the US national neutron reference source. It has a neutron emission rate (June 1961) of 1.257x10 6 n/s 1,2,3 with an uncertainty of 0.85%(k = 1). Neutron emission-rate calibrations performed at the National Institute of Standards and Technology (NIST) are made in comparison to this source, either directly or indirectly. To calibrate a commercial 14 MeV neutron generator, NIST performed a set of comparison measurements to evaluate the neutron output relative to NBS-1. The neutron output of the generator was determined with an uncertainty of about 7%(k = 1). The 15-hour half-life of one of the reactions used also makes possible off-site measurements. Consideration is given to similar calibrations for a 2.5 MeV neutron generator.

  4. Calibration of a neutron probe for determining the humidity in deep alluvial soils

    International Nuclear Information System (INIS)

    Ferrer, A.; Rivero, H.; Lopez, F.; Cantillo, O.

    1993-01-01

    Preliminary data for the calibration of a neutron probe in deep alluvial soils for determining the humidity are reported. Comparisons of Neutron flow behaviour with the depth of the land are established. A characteristic curve of amount of detected neutrons according to the humidity percentage (from 50 to 100 % of the field humidity) is obtained

  5. The characteristic calibration of the plastic scintillation detector for neutron diagnostic

    CERN Document Server

    Chen Hong Su

    2002-01-01

    The author presents the characteristic of the plastic scintillation detector used for pulse neutron diagnostic. The detection efficiency and sensitivity of the detector to DT neutron have been calibrated by the K-400 accelerator and by the pulse neutron tube, separately. The detection efficiency from the experiment is in agreement with that from calculation in the range of experimental errors

  6. Neutron activation procedures used for the calibration of a nitrogen-16 reactor power monitor

    International Nuclear Information System (INIS)

    Jester, W.A.; Daubenspeck, T.

    2000-01-01

    Personnel from the Pennsylvania State University's Breazeale Nuclear Reactor assisted NRC (Nuclear Research Corporation) personnel in calibrating a new MSL/ 16 N Nitrogen-16 Monitor. Neutron flux calibration procedures utilized and the results obtained for the production of a nitrogen-16 source of known activity for a BGO detector calibration are described. (author)

  7. Semi-empirical neutron tool calibration (one and two-group approximation)

    International Nuclear Information System (INIS)

    Czubek, J.A.

    1988-01-01

    The physical principles of the new method of calibration of neutron tools for the rock porosity determination are given. A short description of the physics of neutron transport in the matter is presented together with some remarks on the elementary interactions of neutrons with nuclei (cross sections, group cross sections etc.). The definitions of the main integral parameters characterizing the neutron transport in the rock media are given. The three main approaches to the calibration problem: empirical, theoretical and semi-empirical are presented with some more detailed description of the latter one. The new semi-empirical approach is described. The method is based on the definition of the apparent slowing down or migration length for neutrons sensed by the neutron tool situated in the real borehole-rock conditions. To calculate this apparent slowing down or migration lengths the ratio of the proper space moments of the neutron distribution along the borehole axis is used. Theoretical results are given for one- and two-group diffusion approximations in the rock-borehole geometrical conditions when the tool is in the sidewall position. The physical and chemical parameters are given for the calibration blocks of the Logging Company in Zielona Gora. Using these data the neutron parameters of the calibration blocks have been calculated. An example, how to determine the calibration curve for the dual detector tool applying this new method and using the neutron parameters mentioned above together with the measurements performed in the calibration blocks, is given. The most important advantage of the new semi-empirical method of calibration is the possibility of setting on the unique calibration curve all experimental calibration data obtained for a given neutron tool for different porosities, lithologies and borehole diameters. 52 refs., 21 figs., 21 tabs. (author)

  8. Study on calibration of neutron efficiency and relative photo-yield of plastic scintillator

    International Nuclear Information System (INIS)

    Peng Taiping; Zhang Chuanfei; Li Rurong; Zhang Jianhua; Luo Xiaobing; Xia Yijun; Yang Zhihua

    2002-01-01

    A method used for the calibration of neutron efficiency and the relative photo yield of plastic scintillator is studied. T(p, n) and D(d, n) reactions are used as neutron resources. The neutron efficiencies and the relative photo yields of plastic scintillators 1421 (40 mm in diameter and 5 mm in thickness) and determined in the neutron energy range of 0.655-5 MeV

  9. Technical preparations for the in-vessel 14 MeV neutron calibration at JET

    International Nuclear Information System (INIS)

    Batistoni, P.; Popovichev, S.; Crowe, R.; Cufar, A.; Ghani, Z.; Keogh, K.; Peacock, A.; Price, R.; Baranov, A.; Korotkov, S.; Lykin, P.; Samoshin, A.

    2017-01-01

    Highlights: • The JET 14 MeV neutron calibration requires a neutron generator to be deployed inside the vacuum vessel by means of the remote handling system. • A neutron generator of suitable intensity and compliant with physics, remote handling and safety requirements has been identified and procured.The scientific programme of the preparatory phase devoted to fully characterizing the selected 14 MeV neutron generator is discussed. • The aim is to measure the absolute neutron emission rate within (± 5%) and the energy spectrum of emitted neutron as a function of angles. • The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are discussed. - Abstract: The power output of fusion devices is measured from their neutron yields which relate directly to the fusion yield. In this paper we describe the devices and methods that have been prepared to perform a new in situ 14 MeV neutron calibration at JET in view of the new DT campaign planned at JET in the next years. The target accuracy of this calibration is ±10% as required for ITER, where a precise neutron yield measurement is important, e.g., for tritium accountancy. In this paper, the constraints and early decisions which defined the main calibration approach are discussed, e.g., the choice of 14 MeV neutron source and the deployment method. The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are also discussed. The existing JET remote-handling system will be used to deploy the neutron source inside the JET vessel. For this purpose, compatible tooling and systems necessary to ensure safe and efficient deployment have been developed. The scientific programme of the preparatory phase is devoted to fully characterizing the selected 14 MeV neutron generator to be used as the calibrating source, obtain a better understanding of the limitations of the

  10. Technical preparations for the in-vessel 14 MeV neutron calibration at JET

    Energy Technology Data Exchange (ETDEWEB)

    Batistoni, P., E-mail: paola.batistoni@enea.it [ENEA, Department of Fusion and Nuclear Safety Technology, I-00044, Frascati, Rome (Italy); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Popovichev, S. [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Crowe, R. [Remote Applications in Challenging Environments (RACE), Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Cufar, A. [Reactor Physics Division, Jožef Stefan Institute, Jamova cesta 39, SI-1000, Ljubljana (Slovenia); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Ghani, Z. [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Keogh, K. [Remote Applications in Challenging Environments (RACE), Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Peacock, A. [JET Exploitation Unit, Abingdon, Oxon, OX14 3DB (United Kingdom); Price, R. [Remote Applications in Challenging Environments (RACE), Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Baranov, A.; Korotkov, S.; Lykin, P.; Samoshin, A. [All-Russia Research Institute of Automatics (VNIIA), 22, Sushchevskaya str., 127055, Moscow (Russian Federation)

    2017-04-15

    Highlights: • The JET 14 MeV neutron calibration requires a neutron generator to be deployed inside the vacuum vessel by means of the remote handling system. • A neutron generator of suitable intensity and compliant with physics, remote handling and safety requirements has been identified and procured.The scientific programme of the preparatory phase devoted to fully characterizing the selected 14 MeV neutron generator is discussed. • The aim is to measure the absolute neutron emission rate within (± 5%) and the energy spectrum of emitted neutron as a function of angles. • The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are discussed. - Abstract: The power output of fusion devices is measured from their neutron yields which relate directly to the fusion yield. In this paper we describe the devices and methods that have been prepared to perform a new in situ 14 MeV neutron calibration at JET in view of the new DT campaign planned at JET in the next years. The target accuracy of this calibration is ±10% as required for ITER, where a precise neutron yield measurement is important, e.g., for tritium accountancy. In this paper, the constraints and early decisions which defined the main calibration approach are discussed, e.g., the choice of 14 MeV neutron source and the deployment method. The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are also discussed. The existing JET remote-handling system will be used to deploy the neutron source inside the JET vessel. For this purpose, compatible tooling and systems necessary to ensure safe and efficient deployment have been developed. The scientific programme of the preparatory phase is devoted to fully characterizing the selected 14 MeV neutron generator to be used as the calibrating source, obtain a better understanding of the limitations of the

  11. Absolute calibration of the neutron yield measurement on JT-60 Upgrade

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Takeuchi, Hiroshi; Barnes, C.W.

    1991-10-01

    Absolutely calibrated measurements of the neutron yield are important for the evaluation of the plasma performance such as the fusion gain Q in DD operating tokamaks. Total neutron yield is measured with 235 U and 238 U fission chambers and 3 He proportional counters in JT-60 Upgrade. The in situ calibration was performed by moving the 252 Cf neutron source toroidally through the JT-60 vacuum vessel. Detection efficiencies of three 235 U and two 3 He detectors were measured for 92 locations of the neutron point source in toroidal scans at two different major radii. The total detection efficiency for the torus neutron source was obtained by averaging the point efficiencies over the whole toroidal angle. The uncertainty of the resulting absolute plasma neutron source calibration is estimated to be ± 10%. (author)

  12. Calibration of time of flight detectors using laser-driven neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Mirfayzi, S. R.; Kar, S., E-mail: s.kar@qub.ac.uk; Ahmed, H.; Green, A.; Alejo, A.; Jung, D. [Centre for Plasma Physics, School of Mathematics and Physics, Queen’s University Belfast, Belfast BT7 1NN (United Kingdom); Krygier, A. G.; Freeman, R. R. [Department of Physics, The Ohio State University, Columbus, Ohio 43210 (United States); Clarke, R. [Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom); Fuchs, J.; Vassura, L. [LULI, Ecole Polytechnique, CNRS, Route de Saclay, 91128 Palaiseau Cedex (France); Kleinschmidt, A.; Roth, M. [Institut für Kernphysik, Technische Universität Darmstadt, Schloßgartenstrasse 9, D-64289 Darmstadt,Germany (Germany); Morrison, J. T. [Propulsion Systems Directorate, Air Force Research Lab, Wright Patterson Air Force Base, Ohio 45433 (United States); Najmudin, Z.; Nakamura, H. [Blackett Laboratory, Department of Physics, Imperial College, London SW7 2AZ (United Kingdom); Norreys, P. [Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom); Department of Physics, University of Oxford, Oxford OX1 3PU (United Kingdom); Oliver, M. [Department of Physics, University of Oxford, Oxford OX1 3PU (United Kingdom); Zepf, M. [Centre for Plasma Physics, School of Mathematics and Physics, Queen’s University Belfast, Belfast BT7 1NN (United Kingdom); Helmholtz Institut Jena, D-07743 Jena (Germany); Borghesi, M. [Centre for Plasma Physics, School of Mathematics and Physics, Queen’s University Belfast, Belfast BT7 1NN (United Kingdom); Institute of Physics of the ASCR, ELI-Beamlines Project, Na Slovance 2, 18221 Prague (Czech Republic)

    2015-07-15

    Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

  13. Calibration of time of flight detectors using laser-driven neutron source

    Science.gov (United States)

    Mirfayzi, S. R.; Kar, S.; Ahmed, H.; Krygier, A. G.; Green, A.; Alejo, A.; Clarke, R.; Freeman, R. R.; Fuchs, J.; Jung, D.; Kleinschmidt, A.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.; Norreys, P.; Oliver, M.; Roth, M.; Vassura, L.; Zepf, M.; Borghesi, M.

    2015-07-01

    Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

  14. Calibration of time of flight detectors using laser-driven neutron source

    International Nuclear Information System (INIS)

    Mirfayzi, S. R.; Kar, S.; Ahmed, H.; Green, A.; Alejo, A.; Jung, D.; Krygier, A. G.; Freeman, R. R.; Clarke, R.; Fuchs, J.; Vassura, L.; Kleinschmidt, A.; Roth, M.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.; Norreys, P.; Oliver, M.; Zepf, M.; Borghesi, M.

    2015-01-01

    Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil

  15. Calibration and evaluation of neutron survey meters used at linac facility

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, A.P. [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Pereira, W.W., E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Fonseca, E.S. da; Patrao, K.C.S. [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Batista, D.V.S. [Instituto Nacional do Cancer - INCa, Praca Cruz Vermelha, 23 - centro, CEP 20230-130 Rio de Janeiro (Brazil)

    2010-12-15

    Calibrated survey meters from the Neutron Laboratory of the Instituto de Radioprotecao e Dosimetria (IRD) were used to determine the ambient dose-equivalent rate in a 15 MV linear accelerator treatment room at the Instituto Nacional do Cancer (INCa). Three different models of neutron survey meters were calibrated using four neutron radionuclide neutron sources: {sup 241}AmBe({alpha},n), {sup 252}Cf(f,n), heavy-water moderated {sup 252}Cf(f,n), and {sup 238}PuBe({alpha},n). All neutron sources were standardized in a Manganese Sulphate Bath (MSB) absolute primary system. The response of each of these instruments was compared with reference values of ambient dose-equivalent rate. The results demonstrate the complexity of making measurements in the mixed neutron/photon field produced in electron linear accelerator radiotherapy treatment rooms.

  16. A new technique for the calibration of neutron probes by volumetric method

    International Nuclear Information System (INIS)

    Encarnacao, F.A.F. da.

    1988-01-01

    Laboratory and field studies were performed for the determination of a calibration curve of a neutron probe in three different kinds of soils: Red Yellow PODZOLIC, LITOLIC and ALLUVIAL, in the last one laboratory studies were done to determine local humidity on the calibration curve parameters. (A.C.A.S.) [pt

  17. Characterization of thermal neutron fields for calibration of neutron monitors in accordance with great equivalent dose environment H⁎(10)

    International Nuclear Information System (INIS)

    Silva, Larissa P. S. da; Silva, Felipe S.; Fonseca, Evaldo S.; Patrao, Karla C.S.; Pereira, Walsan W.

    2017-01-01

    The Laboratório Brasileiro de Nêutrons do Instituto de Radioproteção e Dosimetria (IRD/CNEN) has developed and built a thermal neutron flux facility to provide neutron fluence for dosimeters (Astuto, 2014). This fluency is obtained by four 16 Ci sources 241 AmBe (α, n) positioned around the channel positioned in the center of the Thermal Flow Unit (UFT). The UFT was built with blocks of paraffin with graphite addition and graphite blocks of high purity to obtain a central field with a homogeneous thermal neutron fluence for calibration purposes with the following measurements: 1.2 x 1.2 x 1.2 m 3 . The objective of this work is to characterize several points, in the thermal energy range, in terms of the equivalent ambient dose quantity H⁎(10) for calibration and irradiation of monitors neutrons

  18. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    International Nuclear Information System (INIS)

    Tarifeño-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo; Mayer, Roberto E

    2015-01-01

    This work introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from detection of the burst of neutrons. An improvement of more than one order of magnitude in the accuracy of a paraffin wax moderated 3 He-filled tube is obtained by using this methodology with respect to previous calibration methods. (paper)

  19. Experiences in troubleshooting of neutron rem monitor electronics and its subsequent calibration

    International Nuclear Information System (INIS)

    Maithani, Atul; Dash, Amit Kumar; Vijayasekaran, P.; Mathews, Geo; Ajoy, K.C.; Dhanasekaran, A.

    2014-01-01

    This paper deals with the troubleshooting of the signal processing and counting electronics of two no's of Neutron Rem monitors and its subsequent calibration. Electronics servicing with respect to detection of fault in the circuit board, replacement of faulty ICs, circuits (Analog and Digital) tracing and installation of new rechargeable battery pack was done. Electronic calibration using Test pulse generator was carried out for dose rate measurements, amplitude measurements and discriminator level setting. Serial communication settings were checked with both HyperTerminal and software for the monitors. Neutron Source calibration was also carried out for both the monitors. (author)

  20. Calibration of a neutron log in partially saturated media. Part II. Error analysis

    International Nuclear Information System (INIS)

    Hearst, J.R.; Kasameyer, P.W.; Dreiling, L.A.

    1981-01-01

    Four sources or error (uncertainty) are studied in water content obtained from neutron logs calibrated in partially saturated media for holes up to 3 m. For this calibration a special facility was built and an algorithm for a commercial epithermal neutron log was developed that obtains water content from count rate, bulk density, and gap between the neutron sonde and the borehole wall. The algorithm contained errors due to the calibration and lack of fit, while the field measurements included uncertainties in the count rate (caused by statistics and a short time constant), gap, and density. There can be inhomogeneity in the material surrounding the borehole. Under normal field conditions the hole-size-corrected water content obtained from such neutron logs can have an uncertainty as large as 15% of its value

  1. Tests and Calibration of the NIF Neutron Time of Flight Detectors

    International Nuclear Information System (INIS)

    Ali, Z.A.; Glebov, V.Yu.; Cruz, M.; Duffy, T.; Stoeckl, C.; Roberts, S.; Sangster, T.C.; Tommasini, R.; Throop, A; Moran, M.; Dauffy, L.; Horsefield, C.

    2008-01-01

    The National Ignition Facility (NIF) Neutron Time of Flight (NTOF) diagnostic will measure neutron yield and ion temperature in all NIF campaigns in DD, DT, and THD (D = deuterium, T = tritium, H = hydrogen) implosions. The NIF NTOF diagnostic is designed to measure neutron yield from 10 9 to 2 x 10 19 . The NTOF consists of several detectors of varying sensitivity located on the NIF at about 5 m and 20 m from the target. Production, testing, and calibration of the NIF NTOF detectors have begun at the Laboratory for Laser Energetics (LLE). Operational tests of the NTOF detectors were performed on several facilities including the OMEGA laser at LLE and the Titan laser at Lawrence Livermore National Laboratory (LLNL). Neutron calibrations were carried out on the OMEGA laser. Results of the NTOF detectors tests and calibration will be presented

  2. Reference radiation fields - Simulated workplace neutron fields - Part 2: Calibration fundamentals related to the basic quantities

    International Nuclear Information System (INIS)

    2008-01-01

    ISO 8529-1, ISO 8529-2 and ISO 8529-3, deal with the production, characterization and use of neutron fields for the calibration of personal dosimeters and area survey meters. These International Standards describe reference radiations with neutron energy spectra that are well defined and well suited for use in the calibration laboratory. However, the neutron spectra commonly encountered in routine radiation protection situations are, in many cases, quite different from those produced by the sources specified in the International Standards. Since personal neutron dosimeters, and to a lesser extent survey meters, are generally quite energy dependent in their dose equivalent response, it might not be possible to achieve an appropriate calibration for a device that is used in a workplace where the neutron energy spectrum and angular distribution differ significantly from those of the reference radiation used for calibration. ISO 8529-1 describes four radionuclide based neutron reference radiations in detail. This part of ISO 12789 includes the specification of neutron reference radiations that were developed to closely resemble radiation that is encountered in practice

  3. Recent developments in the specification and achievement of realistic neutron calibration fields

    International Nuclear Information System (INIS)

    Chartier, J.L.; Kluges, H.; Wiegel, B.; Schraube, H.

    1997-01-01

    In order to calibrate more accurately the neutron dosemeters involved in radiation protection, the concept of 'Realistic Neutron Calibration Fields' is considered as an appropriate alternative solution, making necessary new irradiation facilities which generate well-characterised neutron fields with energy and angular distribution replicating more closely practical workplace conditions. Several experienced laboratories have collaborated on a European project and proposed various approaches which are reviewed in this paper. A short description of the facilities currently in operation is given as well as a few characteristics of the available radiation fields. This description of the state of art is followed by a discussion of the problems to be solved for using such facilities for calibration purposes according to well-specified calibration procedures. (author)

  4. Absolute calibration of neutron detectors on the C-2U advanced beam-driven FRC

    Energy Technology Data Exchange (ETDEWEB)

    Magee, R. M., E-mail: rmagee@trialphaenergy.com; Clary, R.; Korepanov, S.; Jauregui, F.; Allfrey, I.; Garate, E.; Valentine, T.; Smirnov, A. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    In the C-2U fusion energy experiment, high power neutral beam injection creates a large fast ion population that sustains a field-reversed configuration (FRC) plasma. The diagnosis of the fast ion pressure in these high-performance plasmas is therefore critical, and the measurement of the flux of neutrons from the deuterium-deuterium (D-D) fusion reaction is well suited to the task. Here we describe the absolute, in situ calibration of scintillation neutron detectors via two independent methods: firing deuterium beams into a high density gas target and calibration with a 2 × 10{sup 7} n/s AmBe source. The practical issues of each method are discussed and the resulting calibration factors are shown to be in good agreement. Finally, the calibration factor is applied to C-2U experimental data where the measured neutron rate is found to exceed the classical expectation.

  5. Water calibration measurements for neutron radiography: Application to water content quantification in porous media

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M., E-mail: kangm@ornl.gov [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bilheux, H.Z., E-mail: bilheuxhn@ornl.gov [Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Voisin, S. [Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Cheng, C.L.; Perfect, E. [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Horita, J. [Department of Geosciences, Texas Tech University, Lubbock, TX (United States); Warren, J.M. [Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2013-04-21

    Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 0.2 cm when the water calibration cells were positioned close to the face of the detector/scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

  6. Calibration of ITER Instant Power Neutron Monitors: Recommended Scenario of Experiments at the Reactor

    Science.gov (United States)

    Borisov, A. A.; Deryabina, N. A.; Markovskij, D. V.

    2017-12-01

    Instant power is a key parameter of the ITER. Its monitoring with an accuracy of a few percent is an urgent and challenging aspect of neutron diagnostics. In a series of works published in Problems of Atomic Science and Technology, Series: Thermonuclear Fusion under a common title, the step-by-step neutronics analysis was given to substantiate a calibration technique for the DT and DD modes of the ITER. A Gauss quadrature scheme, optimal for processing "expensive" experiments, is used for numerical integration of 235U and 238U detector responses to the point sources of 14-MeV neutrons. This approach allows controlling the integration accuracy in relation to the number of coordinate mesh points and thus minimizing the number of irradiations at the given uncertainty of the full monitor response. In the previous works, responses of the divertor and blanket monitors to the isotropic point sources of DT and DD neutrons in the plasma profile and to the models of real sources were calculated within the ITER model using the MCNP code. The neutronics analyses have allowed formulating the basic principles of calibration that are optimal for having the maximum accuracy at the minimum duration of in situ experiments at the reactor. In this work, scenarios of the preliminary and basic experimental ITER runs are suggested on the basis of those principles. It is proposed to calibrate the monitors only with DT neutrons and use correction factors to the DT mode calibration for the DD mode. It is reasonable to perform full calibration only with 235U chambers and calibrate 238U chambers by responses of the 235U chambers during reactor operation (cross-calibration). The divertor monitor can be calibrated using both direct measurement of responses at the Gauss positions of a point source and simplified techniques based on the concepts of equivalent ring sources and inverse response distributions, which will considerably reduce the amount of measurements. It is shown that the monitor

  7. Calibration and correction procedures for cosmic-ray neutron soil moisture probes located across Australia

    Science.gov (United States)

    Hawdon, Aaron; McJannet, David; Wallace, Jim

    2014-06-01

    The cosmic-ray probe (CRP) provides continuous estimates of soil moisture over an area of ˜30 ha by counting fast neutrons produced from cosmic rays which are predominantly moderated by water molecules in the soil. This paper describes the setup, measurement correction procedures, and field calibration of CRPs at nine locations across Australia with contrasting soil type, climate, and land cover. These probes form the inaugural Australian CRP network, which is known as CosmOz. CRP measurements require neutron count rates to be corrected for effects of atmospheric pressure, water vapor pressure changes, and variations in incoming neutron intensity. We assess the magnitude and importance of these corrections and present standardized approaches for network-wide analysis. In particular, we present a new approach to correct for incoming neutron intensity variations and test its performance against existing procedures used in other studies. Our field calibration results indicate that a generalized calibration function for relating neutron counts to soil moisture is suitable for all soil types, with the possible exception of very sandy soils with low water content. Using multiple calibration data sets, we demonstrate that the generalized calibration function only applies after accounting for persistent sources of hydrogen in the soil profile. Finally, we demonstrate that by following standardized correction procedures and scaling neutron counting rates of all CRPs to a single reference location, differences in calibrations between sites are related to site biomass. This observation provides a means for estimating biomass at a given location or for deriving coefficients for the calibration function in the absence of field calibration data.

  8. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    Energy Technology Data Exchange (ETDEWEB)

    Tarifeño-Saldivia, Ariel, E-mail: atarifeno@cchen.cl, E-mail: atarisal@gmail.com; Pavez, Cristian; Soto, Leopoldo [Comisión Chilena de Energía Nuclear, Casilla 188-D, Santiago (Chile); Center for Research and Applications in Plasma Physics and Pulsed Power, P4, Santiago (Chile); Departamento de Ciencias Fisicas, Facultad de Ciencias Exactas, Universidad Andres Bello, Republica 220, Santiago (Chile); Mayer, Roberto E. [Instituto Balseiro and Centro Atómico Bariloche, Comisión Nacional de Energía Atómica and Universidad Nacional de Cuyo, San Carlos de Bariloche R8402AGP (Argentina)

    2014-01-15

    This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods.

  9. Calibration methodology for proportional counters applied to yield measurements of a neutron burst

    International Nuclear Information System (INIS)

    Tarifeño-Saldivia, Ariel; Pavez, Cristian; Soto, Leopoldo; Mayer, Roberto E.

    2014-01-01

    This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods

  10. Shielding calculations for neutron calibration bunker using Monte Carlo code MCNP-4C

    International Nuclear Information System (INIS)

    Suman, H.; Kharita, M. H.; Yousef, S.

    2008-02-01

    In this work, the dose arising from an Am-Be source of 10 8 neutron/sec strength located inside the newly constructed neutron calibration bunker in the National Radiation Metrology Laboratories, was calculated using MCNP-4C code. It was found that the shielding of the neutron calibration bunker is sufficient. As the calculated dose is not expected to exceed in inhabited areas 0.183 μSv/hr, which is 10 times smaller than the regulatory dose constraints. Hence, it can be concluded that the calibration bunker can house - from the external exposure point of view - an Am-Be neutron source of 10 9 neutron/sec strength. It turned out that the neutron dose from the source is few times greater than the photon dose. The sky shine was found to contribute significantly to the total dose. This contribution was estimated to be 60% of the neutron dose and 10% of the photon dose. The systematic uncertainties due to various factors have been assessed and was found to be between 4 and 10% due to concrete density variations; 15% due to the dose estimation method; 4 -10% due to weather variations (temperature and moisture). The calculated dose was highly sensitive to the changes in source spectra. The uncertainty due to the use of two different neutron spectra is about 70%.(author)

  11. Calibration of activation detectors in a monoenergetic neutron beam. Contribution to criticality dosimetry

    International Nuclear Information System (INIS)

    Massoutie, Martine.

    1981-05-01

    Activation detectors have been calibrated for critical dosimetry applications. Measurements are made using a monoenergetic neutron flux. 14 MeV neutrons obtained par (D-T) reaction are produced by 150 kV accelerator. Neutron flux determined by different methods leads us to obtain an accuracy better than 6%. The present dosimetric system (Activation Neutron Spectrometer - SNAC) gives few informations in the (10 keV - 2 MeV) energetic range. The system has been improved and modified so that SNAC detectors must be read out by gamma spectrometer [fr

  12. Distinguishing new science from calibration effects in the electron-volt neutron spectrometer VESUVIO at ISIS

    Energy Technology Data Exchange (ETDEWEB)

    Chatzidimitriou-Dreismann, C.A., E-mail: dreismann@chem.tu-berlin.de [Institute of Chemistry (Sekr. C2), Technical University of Berlin, D-10623 Berlin (Germany); Gray, E. MacA., E-mail: e.gray@griffith.edu.au [Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane 4111 (Australia); Blach, T.P., E-mail: t.blach@griffith.edu.au [Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane 4111 (Australia)

    2012-06-01

    The 'standard' procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument's scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron-proton scattering results that together called into question the validity of the 'standard' calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron-deuteron scattering from D{sub 2} in the backscattering angular range ({theta}>90 Degree-Sign ) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the 'standard' calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present 'standard' calibration procedure is seriously deficient and leads to artificial outcomes. For Case (A), we allude to the topic of attosecond quantum dynamical phenomena and our recent neutron scattering experiments from H{sub 2} molecules. For Case (B), some suggestions as to how the 'standard' calibration could be considerably improved are made.

  13. Distinguishing new science from calibration effects in the electron-volt neutron spectrometer VESUVIO at ISIS

    Science.gov (United States)

    Chatzidimitriou-Dreismann, C. A.; Gray, E. MacA.; Blach, T. P.

    2012-06-01

    The "standard" procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument's scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron-proton scattering results that together called into question the validity of the "standard" calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron-deuteron scattering from D2 in the backscattering angular range (θ>90°) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the "standard" calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present "standard" calibration procedure is seriously deficient and leads to artificial outcomes. For Case (A), we allude to the topic of attosecond quantum dynamical phenomena and our recent neutron scattering experiments from H2 molecules. For Case (B), some suggestions as to how the "standard" calibration could be considerably improved are made.

  14. Absolute calibration of TFTR neutron detectors for D-T plasma operation

    International Nuclear Information System (INIS)

    Jassby, D.L.; Johnson, L.C.; Roquemore, A.L.; Strachan, J.D.; Johnson, D.W.; Medley, S.S.; Young, K.M.

    1995-03-01

    The two most sensitive TFTR fission-chamber detectors were absolutely calibrated in situ by a D-T neutron generator (∼5 x 10 7 n/s) rotated once around the torus in each direction, with data taken at about 45 positions. The combined uncertainty for determining fusion neutron rates, including the uncertainty in the total neutron generator output (±9%), counting statistics, the effect of coil coolant, detector stability, cross-calibration to the current mode or log Campbell mode and to other fission chambers, and plasma position variation, is about ±13%. The NE-451 (ZnS) scintillators and 4 He proportional counters that view the plasma in up to 10 collimated sightlines were calibrated by scanning. the neutron generator radially and toroidally in the horizontal midplane across the flight tubes of 7 cm diameter. Spatial integration of the detector responses using the calibrated signal per unit chord-integrated neutron emission gives the global neutron source strength with an overall uncertainty of ±14% for the scintillators and ±15% for the 4 He counters

  15. Rock models at Zielona Gora, Poland applied to the semi-empirical neutron tool calibration

    International Nuclear Information System (INIS)

    Czubek, J.A.; Ossowski, A.; Zorski, T.; Massalski, T.

    1995-01-01

    The semi-empirical calibration method applied to the neutron porosity tool is presented in this paper. It was used with the ODSN-102 tool of 70 mm diameter and equipped with an Am-Be neutron source at the calibration facility of Zielona Gora, Poland, inside natural and artificial rocks: four sandstone, four limestone and one dolomite block with borehole diameters of 143 and 216 mm, and three artificial ceramic blocks with borehole diameters of 90 and 180 mm. All blocks were saturated with fresh water, and fresh water was also inside all boreholes. In five blocks mineralized water (200,000 ppm NaCl) was introduced inside the boreholes. All neutron characteristics of the calibration blocks are given in this paper. The semi-empirical method of calibration correlates the tool readings observed experimentally with the general neutron parameter (GNP). This results in a general calibration curve, where the tool readings (TR) vs GNP are situated at one curve irrespective of their origin, i.e. of the formation lithology, borehole diameter, tool stand-off, brine salinity, etc. The n and m power coefficients are obtained experimentally during the calibration procedure. The apparent neutron parameters are defined as those sensed by a neutron tool situated inside the borehole and in real environmental conditions. When they are known, the GNP parameter can be computed analytically for the whole range of porosity at any kind of borehole diameter, formation lithology (including variable rock matrix absorption cross-section and density), borehole and formation salinity, tool stand-off and drilling fluid physical parameters. By this approach all porosity corrections with respect to the standard (e.g. limestone) calibration curve can be generated. (author)

  16. Safety analyses in support of neutron detector calibration operations at JET

    Energy Technology Data Exchange (ETDEWEB)

    Stankunas, G., E-mail: gediminas@mail.lei.lt [EURATOM-LEI Association, Laboratory of Nuclear Installation Safety, Breslaujos Str. 3, LT-44403 Kaunas (Lithuania); Syme, D.B.; Popovichev, S. [EURATOM-CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Conroy, S. [EURATOM-VR Association, Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Batistoni, P. [JET-EFDA Culham Science Centre, OX14 3DB Abingdon (United Kingdom); EURATOM-ENEA Association, Via E. Fermi, 40, 00044 Frascati (Italy)

    2014-10-15

    Highlights: •Neutron calculations to evaluate the dose rate leakage from the shields which contain the neutron source. •The differences on calculated dose rates using different flux-to-dose conversion factors have been investigated. •The experimental values were compared to the MCNPX calculations. -- Abstract: Neutron detectors in fusion devices need to be calibrated to provide the absolute neutron yield and the fusion power produced in fusion reactions. A new in situ calibration of the JET neutron detectors was recently performed using a {sup 252}Cf neutron source with intensity of about 2.7 × 10{sup 8} n/s. The source was delivered to the JET facility within a transport flask and the surface radiation levels must fall within transport regulations. Some contingency scenarios required transfer of the source into special shields: the operational shield and the auxiliary shield. In this paper we describe the neutron calculations that have been carried out to evaluate the dose rate leakage from the shields which may contain the neutron source. The calculations have been performed using accurate modelling of the neutron and gamma ray emission from the {sup 252}Cf source, and from the three shields. The differences on calculated dose rates deriving from the use of different flux-to-dose conversion factors have also been investigated. A comparison of dose rates calculated and measured is presented from the bare source (in cell) and with the source within its transport flask.

  17. Calibration Curve of Neutron Moisture Meter for Sandy Soil under Drip Irrigation System

    International Nuclear Information System (INIS)

    Mohammad, Abd El- Moniem M.; Gendy, R. W.; Bedaiwy, M. N.

    2004-01-01

    The aim of this work is to construct a neutron calibration curve in order to be able to use the neutron probe in sandy soils under drip irrigation systems. The experimental work was conducted at the Soil and Water Department of the Nuclear Research Center, Atomic Energy Authority. Three replicates were used along the lateral lines of the drip irrigation system. For each dripper, ten neutron access tubes were installed to 100-cm depth at distances of 5, 15 and 25 cm from the dripper location around the drippers on the lateral line, as well as between lateral lines. The neutron calibrations were determined at 30, 45, and 60-cm depths. Determining coefficients as well as t-test in pairs were employed to detect the accuracy of the calibrations. Results indicated that in order for the neutron calibration curve to express the whole wet area around the emitter; three-access tubes must be installed at distances of 5, 15, and 25 cm from the emitter. This calibration curve will be correlating the average count ratio (CR) at the studied soil depth of the three locations (5, 15, and 25-cm distances from the emitter) to the average moisture content (θ) for this soil depth of the entire wetted area. This procedure should be repeated at different times in order to obtain different θ and C.R values, so that the regression equation of calibration curve at this soil depth can be obtained. To determine the soil moisture content, the average CR of the three locations must be taken and substituted into the regression equation representing the neutron calibration curve. Results taken from access tubes placed at distances of 15 cm from the emitter, showed good agreement with the average calibration curve both for the 45- and the 60-cm depths, suggesting that the 15-cm distance may provide a suitable substitute for the simultaneous use of the three different distances of 5, 15 and 25 cm. However, the obtained results show also that the neutron calibration curves of the 30-cm depth for

  18. Simulation of a room for neutron instrument calibration at LCR/UERJ

    International Nuclear Information System (INIS)

    Medeiros, M.P.C.; Estrada, J.J.S.; Gomes, R.G.; Santos, R.F.G.; Leite, S.P.; Alves, C.F.E.; Rebello, W.F.; Almeida, C.E. de

    2013-01-01

    In this work the MCNPX code was used to design a calibrating room for neutron detectors to be implemented in the Laboratorio de Ciencias Radiologicas of UERJ. The calibration room containing a neutron irradiator with a 241 Am-Be source, a linear positioning system, radiation detectors and a shadow cone was modeled. The ambient dose equivalent rate, ııı ∗ ı10ı, in adjacent to the calibration room areas, as well as neutron scattering caused by the room itself were calculated. Using an occupancy factor of 1/16 for all adjacent areas, 3.8 cm of 5% borated polyethylene or 5.5 cm of concrete for shielding is enough to satisfy radiation safety requirements. (author)

  19. In-situ calibration of TFTR [Tokamak Fusion Test Reactor] neutron detectors

    International Nuclear Information System (INIS)

    Hendel, H.W.; Palladino, R.W.; Barnes, C.W.; Diesso, M.; Felt, J.S.; Jassby, D.L.; Johnson, L.C.; Ku, L.P.; Liu, Q.P.; Motley, R.W.; Murphy, H.B.; Murphy, J.; Nieschmidt, E.B.; Roberts, J.A.; Saito, T.; Strachan, J.D.; Waszazak, R.J.; Young, K.

    1990-03-01

    We report results of the TFTR fission detector calibration performed in December 1988. A NBS-traceable, remotely controlled 252 Cf neutron source was moved toroidally through the TFTR vacuum vessel. Detection efficiencies for two 235 U detectors were measured for 930 locations of the neutron point source in toroidal scans at 16 different major radii and vertical heights. These scans effectively simulated the volume-distributed plasma neutron source, and the volume-integrated detection efficiency was found to be insensitive to plasma position. The Campbell mode is useful due to its large overlap with the count rate mode and large dynamic range. The resulting absolute plasma neutron source calibration has an uncertainty of ± 13%. 21 refs., 23 figs., 4 tabs

  20. Field calibration of a TLD albedo dosemeter in the high-energy neutron field of CERF

    International Nuclear Information System (INIS)

    Haninger, T.; Kleinau, P.; Haninger, S.

    2017-01-01

    The new albedo dosemeter-type AWST-TL-GD 04 has been calibrated in the CERF neutron field (CERN-EU high-energy Reference Field). This type of albedo dosemeter is based on thermoluminescent detectors (TLDs) and used by the individual monitoring service of the Helmholtz Zentrum Muenchen (AWST) since 2015 for monitoring persons, who are exposed occupationally against photon and neutron radiation. The motivation for this experiment was to gain a field specific neutron correction factor N n for workplaces at high-energy particle accelerators. N n is a dimensionless factor relative to a basic detector calibration with 137 Cs and is used to calculate the personal neutron dose in terms of H p (10) from the neutron albedo signal. The results show that the sensitivity of the albedo dosemeter for this specific neutron field is not significantly lower as for fast neutrons of a radionuclide source like 252 Cf. The neutron correction factor varies between 0.73 and 1.16 with a midrange value of 0.94. The albedo dosemeter is therefore appropriate to monitor persons, which are exposed at high-energy particle accelerators. (authors)

  1. A new philosophy for calibrating oil well logging tools based on neutron transport codes

    International Nuclear Information System (INIS)

    Butler, J.; Clayton, C.G.

    1984-01-01

    The current practice of calibrating neutron borehole logging probes is limited by an inability to match calibration conditions to those which pertain in an operational situation. In addition, test boreholes are expensive to construct and, when natural materials are used, rely on an exact correspondence in composition and in structure between the materials of the test facility and representative samples which may not be valid. Now that neutron tansport codes have been developed to a point at which they are able to cope with realistic, complex situations an alternative approach to calibration can be considered. The basis of this philosophy is the construction of a limited number of calibration facilities which are composed of artificial rocks of controlled but variable porosity and accurately known nuclear characteristics

  2. An in-situ check of the epithermal neutron log calibration

    International Nuclear Information System (INIS)

    Burkhard, N.R.

    1993-01-01

    The epithermal neutron log is used to measure the water content of the formation. The large hole epithermal neutron sonde (ENS) utilized at the Nevada Test Site (NTS) has been calibrated in the Hydrogen Content Test Facility (HCTF). These calibrations are used to correct the measured neutron count rate for the effects of tool stand-off and density. For some time, the suspicion has existed that the water contents that are calculated from the ENS data are too large. Hole U2gj represented a unique opportunity to check the validity of the ENS calibration under realistic logging conditions; a portion of the hole had been cemented and redrilled and then logged. The cements have a known water content and can be used as an in-situ calibration check. The author found that the water contents from the log data after processing with the existing calibrations are consistent with these known cement water contents. In addition, the study indicates that the raw neutron data might be more appropriately smoothed by using a median smoother rather than the currently utilized mean smoother

  3. An in-situ check of the epithermal neutron log calibration

    International Nuclear Information System (INIS)

    Burkhard, N.R.

    1993-09-01

    The epithermal neutron log is used to measure the water content of the formation. The large hole epithermal neutron sonde (ENS) that we utilize at the Nevada Test Site (NTS) has been calibrated in the Hydrogen Content Test Facility (HCTF). These calibrations are used to correct the measured neutron count rate for the effects of tool stand-off and density. For sometime, the suspicion has existed that the water contents that are calculated from the ENS data are too large. Hole U2gj represented a unique opportunity to check the validity of the ENS calibration under realistic logging conditions; a portion of the hole had been cemented and re drilled and then logged. The cements have a known water content and can be used as an in situ calibration check. I found that the water contents from the log data after processing with the existing calibrations are consistent with these known cement water contents. In addition, the study indicates that the raw neutron data might be more appropriately smoothed by using a median smoother rather than the currently utilized mean smoother

  4. Calibration of SSTR neutron dosimetry for TMI-2 applications

    International Nuclear Information System (INIS)

    Gold, R.; Ruddy, F.H.; Roberts, J.H.; Preston, C.C.; Ulseth, J.A.; McElroy, W.N.; Leitz, F.J.; Hayward, B.R.; Schmittroth, F.A.

    1982-01-01

    Application of neutron dosimetry for assessment of fuel distribution throughout the Three Mile Island-2 (TMI-2) reactor-core region and the primary-coolant system is advanced. Neutron dosimetry in the reactor cavity, i.e. the cavity between the pressure vessel and the biological shield, could provide data for the assessment of the core fuel distribution. A more immediate task entails locating and quantifying the amount of fuel debris in the ex-core primary coolant system; in the range of 1 to 1000 kg. Solid-state track-recorder (SSTR) neutron dosimetry is considered for such exploratory scoping experiments at TMI-2. The sensitivity of mica- 235 U (asymptotically thick) SSTR has been ascertained for such environments. It has been demonstrated that the SSTR method has adequate sensitivity to properly respond and detect fuel quantities of the order of 1 kg in the ex-core primary coolant system. 21 figures

  5. Initial absolute calibration factors for some neutron sensitive self-powered detectors

    International Nuclear Information System (INIS)

    Kroon, J.

    1975-01-01

    Self-powered flux detectors have found extensive use as monitoring devices in PWR (Pressurized Water Reactor) cores and CANDU (Canada Deuterium Uranium) type power reactors. The detectors measure fuel power distributions and indicate trip parameters for reactor control and safety requirements. Both applications demand accurate absolute initial calibration factors. Experimental results obtained in calibrating some neutron sensitive self-powered detectors is presented. (author)

  6. Determination of the scattered radiation at the Neutron Calibration Laboratory of IPEN, SP, Brazil

    International Nuclear Information System (INIS)

    Alvarenga, Tallyson; Valeriano, Caio C.S.; Caldas, Linda V.E.; Federico, Claudio A.

    2016-01-01

    With the increased use of techniques using neutron radiation, there has been a considerable growth in the number of detectors for this kind of radiation. A neutron calibration laboratory with neutron radiation ("2"4"1AmBe) was designed. In practical situations of this type of laboratory, one of the main problems is related to the knowledge of scattered radiation. In order to evaluate this scattered radiation, simulations were carried out without the presence of structural elements and with the complete room. Fourteen measuring points were evaluated in different directions at various distances. (author)

  7. Bayesian calibration of reactor neutron flux spectrum using activation detectors measurements: Application to CALIBAN reactor

    International Nuclear Information System (INIS)

    Cartier, J.; Casoli, P.; Chappert, F.

    2013-01-01

    In this paper, we present calibration methods in order to estimate reactor neutron flux spectrum and its uncertainties by using integral activation measurements. These techniques are performed using Bayesian and MCMC framework. These methods are applied to integral activation experiments in the cavity of the CALIBAN reactor. We estimate the neutron flux and its related uncertainties. The originality of this work is that these uncertainties take into account measurements uncertainties, cross-sections uncertainties and model error. In particular, our results give a very good approximation of the total flux and indicate that neutron flux from MCNP simulation for energies above about 5 MeV seems to overestimate the 'real flux'. (authors)

  8. Calibration of the time response functions of a quenched plastic scintillator for neutron time of flight

    CERN Document Server

    Chen, J B; Peng, H S; Tang, C H; Zhang, B H; Ding, Y K; Chen, M; Chen, H S; Li, C G; Wen, T S; Yu, R Z

    2002-01-01

    The time response functions of an ultrafast quenched plastic scintillation detector used to measure neutron time of flight spectra were calibrated by utilizing cosmic rays and implosion neutrons from DT-filled capsules at the Shenguang II laser facility. These sources could be regarded as delta function pulses due to their much narrower time widths than those of the time response functions of the detection system. The results showed that the detector responses to DT neutrons and to cosmic rays were 1.18 and 0.96 ns FWHM, respectively.

  9. The calibration method for personal dosimetry system in photon and neutron radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J; Plichta, J [CSOD, Prague (Czech Republic); Nikodemova, D [SOD, Bratislava (Slovakia)

    1996-12-31

    The type testing of dosimetry system was performed with standard photon radiation fields within the energy range 15 keV to 1.25 MeV and electron radiation fields within the range 0.2 MeV to 3 MeV. For type testing of neutron dosimeters {sup 252}Cf and {sup 241}Am-Be radionuclide neutron sources was used, as well as a 14 MeV neutron generator. The neutron sources moderated by various moderating and absorbing materials was also used. The routine calibration of individual photon dosemeters was carried out using a {sup 137}Cs calibration source in the air kerma quality in the dose range 0.2 mGy to 6 Gy. The type testing of neutron dosemeters was performed in collaboration with Nueherberg laboratory on neutron generator with neutron energies -.57; 1.0;; 5.3 and 15.1 MeV. The fading and angular dependence testing was also included in the tests of both dosemeter systems. (J.K.).

  10. Neutron Arm Study and Calibration for the GEn Experiment at Thomas Jefferson National Laboratory

    International Nuclear Information System (INIS)

    Timothy Ngo

    2007-01-01

    The measurement of the neutron electric form factor, GEn, will allow us to solve indirectly for the quark charge distribution inside of the neutron. With the equipment at Jefferson Lab we have measured GEn at four momentum transfer values of Q**2 at 1.3, 2.4 and 3.4 (GeV/c)**2 using a polarized electron beam and polarized Helium target. The scattered electrons off of the Helium target are detected in the BigBite spectrometer and the recoiling neutrons from the Helium are detected in the Neutron Arm, which is composed of an array of scintillators. The main focus of this thesis will be devoted to the geometry, timing and energy calibrations of the Neutron Arm

  11. Calibration of LiBaF sub 3 Ce scintillator for fission spectrum neutrons

    CERN Document Server

    Reeder, P L

    2002-01-01

    The scintillator LiBaF sub 3 doped with small amounts of Ce sup + sup 3 has the ability to distinguish heavy charged particles (p, d, t, or alpha) from beta and/or gamma radiation based on the presence or absence of nanosecond components in the scintillation light output. Since the neutron capture reaction on sup 6 Li produces recoil alphas and tritons, this scintillator also discriminates between neutron induced events and beta or gamma interactions. An experimental technique using a time-tagged sup 2 sup 5 sup 2 Cf source has been used to measure the efficiency of this scintillator for neutron capture, the calibration of neutron capture pulse height, and the pulse height resolution--all as a function of incident neutron energy.

  12. Construction of monoenergetic neutron calibration fields using 45Sc(p, n)45Ti reaction at JAEA.

    Science.gov (United States)

    Tanimura, Y; Saegusa, J; Shikaze, Y; Tsutsumi, M; Shimizu, S; Yoshizawa, M

    2007-01-01

    The 8 and 27 keV monoenergetic neutron calibration fields have been developed by using (45)Sc(p, n)(45)Ti reaction. Protons from a 4-MV Pelletron accelerator are used to bombard a thin scandium target evaporated onto a platinum disc. The proton energies are finely adjusted to the resonance to generate the 8 and 27 keV neutrons by applying a high voltage to the target assemblies. The neutron energies were measured using the time-of-flight method with a lithium glass scintillation detector. The neutron fluences at a calibration point located at 50 cm from the target were evaluated using Bonner spheres. A long counter was placed at 2.2 m from the target and at 60 degrees to the direction of the proton beam in order to monitor the fluence at the calibration point. Fluence and dose equivalent rates at the calibration point are sufficient to calibrate many types of the neutron survey metres.

  13. Calibration and Monte Carlo modelling of neutron long counters

    CERN Document Server

    Tagziria, H

    2000-01-01

    The Monte Carlo technique has become a very powerful tool in radiation transport as full advantage is taken of enhanced cross-section data, more powerful computers and statistical techniques, together with better characterisation of neutron and photon source spectra. At the National Physical Laboratory, calculations using the Monte Carlo radiation transport code MCNP-4B have been combined with accurate measurements to characterise two long counters routinely used to standardise monoenergetic neutron fields. New and more accurate response function curves have been produced for both long counters. A novel approach using Monte Carlo methods has been developed, validated and used to model the response function of the counters and determine more accurately their effective centres, which have always been difficult to establish experimentally. Calculations and measurements agree well, especially for the De Pangher long counter for which details of the design and constructional material are well known. The sensitivit...

  14. Neutron activation analysis for calibration of phosphorus implantation dose

    International Nuclear Information System (INIS)

    Paul, Rick L.; Simons, David S.

    2001-01-01

    A feasibility study was undertaken to determine if radiochemical neutron activation analysis (RNAA) can be used to certify the retained dose of phosphorus implanted in silicon, with the goal of producing a phosphorus SRM. Six pieces of silicon, implanted with a nominal phosphorus dose of 8.5x10 14 atoms·cm -2 were irradiated at a neutron flux of 1.05x10 14 cm -2 ·s -1 . The samples were mixed with carrier, dissolved in acid, the phosphorus isolated by chemical separation, and 32 P measured using a beta proportional counter. A mean phosphorus concentration of (8.35±0.20)x10 14 atoms·cm -2 (uncertainty=1 standard deviation) was determined for the six samples, in agreement with the nominal implanted dose

  15. Calibration of the JET neutron yield monitors using the delayed neutron counting technique

    International Nuclear Information System (INIS)

    van Belle, P.; Jarvis, O.N.; Sadler, G.; de Leeuw, S.; D'Hondt, P.; Pillon, M.

    1990-01-01

    The time-resolved neutron yield is routinely measured on the JET tokamak using a set of fission chambers. At present, the preferred technique is to employ activation reactions to determine the neutron fluence at a well-chosen position and to relate the measured fluence to the total neutron emission by means of neutron transport calculations. The delayed neutron counting method is a particularly convenient method of performing the activation measurement and the fission cross sections are accurately known. This paper outlines the measurement technique as used on JET

  16. Calibration of a D-T neutron generator

    International Nuclear Information System (INIS)

    Ito, Tadayuki

    1980-01-01

    The energy and production rate of neutrons from a thick target are discussed. The production rate of D-T neutrons is estimated by counting alpha particles with a silicon detector. In this case, it is necessary to evaluate a correction factor from the energy of deuteron, the reaction cross section, the stopping power of target materials and others. The factor was calculated and is shown in a figure. The energy spectrum of emitted neutrons is also estimated, where the atomic ratio of T and Ti is taken as a parameter. The shape of the spectrum is determined by the reaction cross section, and is not dependent on the ratio T/Ti. The errors due to competitive reactions, such as D(d, n) and D(d, p), are negligible. It is necessary for mutual comparison to take care of the target thickness, the acceleration voltage of D beam, the alpha-detector position, and the gain fluctuation of electronic circuits. (Kato, T.)

  17. Field test and calibration of neutron coincidence counters for high-mass plutonium samples

    International Nuclear Information System (INIS)

    Menlove, H.O.; Dickinson, R.J.; Douglas, I.

    1987-02-01

    Five different neutron coincidence systems were evaluated and calibrated for high-mass PuO 2 samples. The samples were from 2 to 7.2 kg of PuO 2 in mass, with a large range of burnup. This report compares the equipment and the results, with an evaluation of deadtime and multiplication corrections

  18. Calibration of a Neutron Hydroprobe for Moisture Measurements in Small-Diameter Steel-Cased Boreholes

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Anderson L.; Wittman, Richard S.

    2009-08-01

    Computation of soil moisture content from thermalized neutron counts for the T-Farm Interim cover requires a calibration relationship but none exists for 2-in tubes. A number of calibration options are available for the neutron probe, including vendor calibration, field calibration, but none of these methods were deemed appropriate for the configuration of interest. The objective of this work was to develop a calibration relation for converting neutron counts measured in 2-in access tubes to soil water content. The calibration method chosen for this study was a computational approach using the Monte Carlo N-Particle Transport Code (MCNP). Model calibration was performed using field measurements in the Hanford calibration models with 6-in access tubes, in air and in the probe shield. The bet-fit model relating known water content to measured neutron counts was an exponential model that was essentially equivalent to that currently being used for 6-in steel cased wells. The MCNP simulations successfully predicted the neutron count rate for the neutron shield and the three calibration models for which data were collected in the field. However, predictions for air were about 65% lower than the measured counts . This discrepancy can be attributed to uncertainties in the configuration used for the air measurements. MCNP-simulated counts for the physical models were essentially equal to the measured counts with values. Accurate prediction of the response in 6-in casings in the three calibration models was motivation to predict the response in 2-in access tubes. Simulations were performed for six of the seven calibration models as well as 4 virtual models with the entire set covering a moisture range of 0 to 40%. Predicted counts for the calibration models with 2-in access tubes were 40 to 50% higher than in the 6-inch tubes. Predicted counts for water were about 60% higher in the 2-in tube than in the 6-in tube. The discrepancy between the 2-in and 6-in tube can be

  19. Calibration of a NE213 detector for neutron spectroscopy; Calibracion de un detector de NE213 para espectroscopia de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Blazquez Martinez, J; Butragueno Casado, J L

    1974-07-01

    This work describes the experimental way followed for getting the calibration of a NE213 detector with a beam of neutrons from the J.E.N. 2 MeV Van de Graaff and using at once pulse shape discrimination. Detector has been used for measuring the spectrum of the fast reactor CORAL-1. There is also included an experimental method in order to get with precision where the Compton edge is placed on the electron spectrum. (Author) 9 refs.

  20. Distinguishing new science from calibration effects in the electron-volt neutron spectrometer VESUVIO at ISIS

    International Nuclear Information System (INIS)

    Chatzidimitriou-Dreismann, C.A.; Gray, E. MacA.; Blach, T.P.

    2012-01-01

    The “standard” procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument's scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron–proton scattering results that together called into question the validity of the “standard” calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron–deuteron scattering from D 2 in the backscattering angular range (θ>90°) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the “standard” calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present “standard” calibration procedure is seriously deficient and leads to artificial outcomes. For Case (A), we allude to the topic of attosecond quantum dynamical phenomena and our recent neutron scattering experiments from H 2 molecules. For Case (B), some suggestions as to how the “standard” calibration could be considerably improved are made.

  1. High voltage calibration of the TANSY-KM5 neutron detectors

    International Nuclear Information System (INIS)

    Grosshoeg, G.; Belle, P. van; Wilson, D.

    1996-11-01

    We have developed a procedure for the high voltage calibration of the TANSY neutron detectors. The procedure is based on the work done during the construction of the spectrometer. A program is written for the measurement of the sensitivity of the neutron detectors as a function of the high voltage. The data are transferred to a PC for evaluation. We use a Cobalt source for the calibration. With the PC the voltage corresponding to the effective Compton edge is found. The voltage settings for the neutron detectors are calculated and stored in a file suitable for input to a program that is used to control the instrument. A measurement is reported that shows that the reproducibility of the measurement is good. 4 refs

  2. Establishment of calibration curve for water measurement in a bulky paper recycling by neutron device

    International Nuclear Information System (INIS)

    Norpaiza Mohamad Hasan; Glam Hadzir Patai Mohamad; Rasif Mohd Zain; Ismail Mustapha

    2010-01-01

    A bulk used paper supplied to recycling industry may contain water in their internal voids. This is because the price of the used paper is currently based on their weight and has a huge potential of suppliers to add with water in order to increase the price. Currently used methods for moisture content in a paper are restricted to sheet of paper only. This paper presents a non-intrusive method for quick and in-situ measurement of water content in a bulky used paper. A fast neutron source (Am-Be 241) and a portable backscattering neutron detector are used for water measurement. The experiment is carried out by measuring a series of wet paper that added with known amount of water. As consequent, a neutron calibration curve for water measurement in a bulky used paper is obtained. Six categories of calibration curve have been proposed for correction of weight measurement during purchasing of used paper. (author)

  3. The sensitivity calibration of the ultra-fast quench plastic scintillation detector for D-T neutrons

    International Nuclear Information System (INIS)

    Tang Changhuan; Yan Meiqiong; Xie Chaomei

    1998-01-01

    The authors introduce some characteristics of ultra-fast quench plastic scintillation detectors. When the detectors are composed of different scintillators, light guides and microchannel plate photomultiplier tube (MCP-PMT), their sensitivities to D-T neutrons are calibrated by a pulse neutron tube with a neutron pulse width about 10 ns

  4. Absolute efficiency calibration of 6LiF-based solid state thermal neutron detectors

    Science.gov (United States)

    Finocchiaro, Paolo; Cosentino, Luigi; Lo Meo, Sergio; Nolte, Ralf; Radeck, Desiree

    2018-03-01

    The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations of thermal neutron detectors, characterized by reasonable efficiency and gamma rejection comparable to 3He tubes. In this paper we show the state of the art of a promising low-cost technique, based on commercial solid state silicon detectors coupled with thin neutron converter layers of 6LiF deposited onto carbon fiber substrates. A few configurations were studied with the GEANT4 simulation code, and the intrinsic efficiency of the corresponding detectors was calibrated at the PTB Thermal Neutron Calibration Facility. The results show that the measured intrinsic detection efficiency is well reproduced by the simulations, therefore validating the simulation tool in view of new designs. These neutron detectors have also been tested at neutron beam facilities like ISIS (Rutherford Appleton Laboratory, UK) and n_TOF (CERN) where a few samples are already in operation for beam flux and 2D profile measurements. Forthcoming applications are foreseen for the online monitoring of spent nuclear fuel casks in interim storage sites.

  5. Calibration of the GNU and HSREM neutron survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    Eakins, J.S., E-mail: jonathan.eakins@phe.gov.uk [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Hager, L.G. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Leake, J.W.; Mason, R.S. [Sherwood Nutec Scientific Ltd., Kent (United Kingdom); Tanner, R.J. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2017-04-21

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  6. Calibration of the GNU and HSREM neutron survey instruments

    International Nuclear Information System (INIS)

    Eakins, J.S.; Hager, L.G.; Leake, J.W.; Mason, R.S.; Tanner, R.J.

    2017-01-01

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  7. The vein collar

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    Randomized studies evaluating the effect of a vein collar at the distal anastomosis of PTFE-grafts show conflicting results. The study of the Joint Vascular Research Group (JVRG) of UK found improved primary patency while the Scandinavian Miller Collar Study (SCAMICOS) found neither any effect...

  8. Neutron Irradiation Tests of Calibrated Cryogenic Sensors at Low Temperatures

    CERN Document Server

    Junquera, T; Thermeau, J P; Casas-Cubillos, J

    1998-01-01

    This paper presents the advancement of a program being carried out in view of selecting the cryogenic temperature sensors to be used in the LHC accelerator. About 10,000 sensors will be installed around the 26.6 km LHC ring, and most of them will be exposed to high radiation doses during the accelerator lifetime. The following thermometric sensors : carbon resistors, thin films, and platinum resistors, have been exposed to high neutron fluences (>10$^15$ n/cm$^2$) at the ISN (Grenoble, France) Cryogenic Irradiation Test Facility. A cryostat is placed in a shielded irradiation vault where a 20 MeV deuteron beam hits a Be target, resulting in a well collimated and intense neutron beam. The cryostat, the on-line acquisition system, the temperature references and the main characteristics of the irradiation facility are described. The main interest of this set-up is its ability to monitor online the evolution of the sensors by comparing its readout with temperature references that are in principle insensitive to t...

  9. Characterization of the neutron field of the 241AmBe in a calibration room

    International Nuclear Information System (INIS)

    Vega C, H.R.; Gallego, E.; Lorente, A.

    2003-01-01

    The field of neutrons produced by an isotopic source of neutrons of 241 Am Be had been characterized. The characterization was carried out modeling those relevant details of the calibration room and simulating the neutron transport at different distances of the source. The calculated spectra were used to determine the equivalent environmental dose rate. A series of experiments were carried out with the Bonner sphere spectrometric system to measure the spectra in the same points where the calculations were carried out and with these spectra the rates of environmental dose were calculated. By means of a one sphere dosemeter type Berthold the rates of environmental dose were measured. To the one to compare the calculated spectra and measured its were found small differences in the group of the thermal neutrons due to the elementary composition used during the simulation. When comparing the derived rates starting from the calculated spectra with those measured it was found a maxim difference smaller to 13%. (Author)

  10. Nanotubes based neutron generator for calibration of neutrino and dark matter detectors

    Science.gov (United States)

    Chepurnov, A. S.; Ionidi, V. Y.; Kirsanov, M. A.; Kitsyuk, E. P.; Klenin, A. A.; Kubankin, A. S.; Oleinik, A. N.; Pavlov, A. A.; Shchagin, A. V.

    2017-12-01

    The compact 2.45 MeV fast neutron generator with a reduced supply voltage for calibration of low-background neutrino and dark matter detectors was tested. The generator is based on an array of carbon nanotubes. Neutron generation is carried out by applying a high voltage in the range of +10 to + 25 kV to a nanotube array, which cause an ionization of deuterium molecules with the following acceleration of ions in the direction of the grounded target covered by a deuterated polyethylene film. The d(d,n)3He nuclear reaction happens as the result of ions collisions with the target. The dependences of the neutron yield as functions of the applied voltage were obtained for two different types of carbon nanotubes array. It is shown that the type of nanotubes array does not influence significantly on the neutron yield.

  11. Calibration of a detector by activation with a continuous neutron source used as a transfer standard for measuring pulsed neutron beams

    International Nuclear Information System (INIS)

    Moreno, Jose; Silva, Patricio; Birstein, Lipo; Soto, Leopoldo

    2002-01-01

    This paper presents a method for calibrating activation detectors. These detectors will be used as transfer standard in measuring neutron fluxes produced by pulsed plasma sources. A standard neutron source is used as a secondary standard. The activation detector is being shielded in order to substantially reduce detection of gamma emission coming from the source. The detector's calibration factor is obtained by considering also the standard neutron source as a free source of gamma radiation so that the measurements can be done without quickly withdrawing the neutron source as it is usually done. This will substantially simplify the traditionally established method (JM)

  12. Self-Powered Neutron Detector Calibration Using a Large Vertical Irradiation Hole of HANARO

    Directory of Open Access Journals (Sweden)

    Kim Myong-Seop

    2018-01-01

    Full Text Available A calibration technology of the self-powered neutron detectors (SPNDs using a large vertical irradiation hole of HANARO is developed. The 40 Rh-SPNDs are installed on the polycarbonate plastic support, and the gold wires with the same length as the effective length of the rhodium emitter of the SPND are also installed to measure the neutron flux on the SPND. They are irradiated at a low reactor power, and the SPND current is measured using the pico-ammeter. The external gamma-rays which affect the SPND current response are analyzed using the Monte Carlo simulation for various irradiation conditions in HANARO. It is confirmed that the effect of the external gamma-rays to the SPND current is dependent on the reactor characteristics, and that it is affected by materials around the detector. The current signals due to the external gamma-rays can be either positive or negative, in that the net flow of the current may be either in the same or the opposite direction as the neutron-induced current by the rhodium emitter. From the above procedure, the effective calibration methodology of multiple SPNDs using the large hole of HANARO is developed. It could be useful for the calibration experiment of the neutron detectors in the research reactors.

  13. Self-Powered Neutron Detector Calibration Using a Large Vertical Irradiation Hole of HANARO

    Science.gov (United States)

    Kim, Myong-Seop; Park, Byung-Gun; Kang, Gi-Doo

    2018-01-01

    A calibration technology of the self-powered neutron detectors (SPNDs) using a large vertical irradiation hole of HANARO is developed. The 40 Rh-SPNDs are installed on the polycarbonate plastic support, and the gold wires with the same length as the effective length of the rhodium emitter of the SPND are also installed to measure the neutron flux on the SPND. They are irradiated at a low reactor power, and the SPND current is measured using the pico-ammeter. The external gamma-rays which affect the SPND current response are analyzed using the Monte Carlo simulation for various irradiation conditions in HANARO. It is confirmed that the effect of the external gamma-rays to the SPND current is dependent on the reactor characteristics, and that it is affected by materials around the detector. The current signals due to the external gamma-rays can be either positive or negative, in that the net flow of the current may be either in the same or the opposite direction as the neutron-induced current by the rhodium emitter. From the above procedure, the effective calibration methodology of multiple SPNDs using the large hole of HANARO is developed. It could be useful for the calibration experiment of the neutron detectors in the research reactors.

  14. Determination of the scattered radiation at the Neutron Calibration Laboratory of IPEN using the shadow cone method

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Tallyson S.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Freitas, Bruno M. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Fonseca, Evaldo S.; Pereira, Walsan W., E-mail: talvarenga@ipen.br, E-mail: lcaldas@ipen.br, E-mail: bfreitas@con.ufrj.br, E-mail: walsan@ird.gov.br, E-mail: evaldo@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Because of the increase in the demand for the calibration of neutron detectors, there is a need for new calibration services. In this context, the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (IPEN), São Paulo, which already offers calibration services of radiation detectors with standard X, gamma, beta and alpha beams, has recently projected a new test laboratory for neutron detectors. This work evaluated the contribution of dispersed neutron radiation in this laboratory, using the cone shadow method and a Bonner sphere spectrometer to take the measurements at a distance of 100 cm from the neutron source. The dosimetric quantities H⁎(10) and H⁎(10) were obtained at the laboratory, allowing the calibration of detectors. (author)

  15. Determination of the scattered radiation at the Neutron Calibration Laboratory of IPEN using the shadow cone method

    International Nuclear Information System (INIS)

    Alvarenga, Tallyson S.; Caldas, Linda V.E.; Freitas, Bruno M.

    2017-01-01

    Because of the increase in the demand for the calibration of neutron detectors, there is a need for new calibration services. In this context, the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (IPEN), São Paulo, which already offers calibration services of radiation detectors with standard X, gamma, beta and alpha beams, has recently projected a new test laboratory for neutron detectors. This work evaluated the contribution of dispersed neutron radiation in this laboratory, using the cone shadow method and a Bonner sphere spectrometer to take the measurements at a distance of 100 cm from the neutron source. The dosimetric quantities H⁎(10) and H⁎(10) were obtained at the laboratory, allowing the calibration of detectors. (author)

  16. Investigation of Workplace-like Calibration Fields via a Deuterium-Tritium (D-T) Neutron Generator.

    Science.gov (United States)

    Mozhayev, Andrey V; Piper, Roman K; Rathbone, Bruce A; McDonald, Joseph C

    2017-04-01

    Radiation survey meters and personal dosimeters are typically calibrated in reference neutron fields based on conventional radionuclide sources, such as americium-beryllium (Am-Be) or californium-252 (Cf), either unmodified or heavy-water moderated. However, these calibration neutron fields differ significantly from the workplace fields in which most of these survey meters and dosimeters are being used. Although some detectors are designed to yield an approximately dose-equivalent response over a particular neutron energy range, the response of other detectors is highly dependent upon neutron energy. This, in turn, can result in significant over- or underestimation of the intensity of neutron radiation and/or personal dose equivalent determined in the work environment. The use of simulated workplace neutron calibration fields that more closely match those present at the workplace could improve the accuracy of worker, and workplace, neutron dose assessment. This work provides an overview of the neutron fields found around nuclear power reactors and interim spent fuel storage installations based on available data. The feasibility of producing workplace-like calibration fields in an existing calibration facility has been investigated via Monte Carlo simulations. Several moderating assembly configurations, paired with a neutron generator using the deuterium tritium (D-T) fusion reaction, were explored.

  17. Estimation of scattering contribution in the calibration of neutron devices with radionuclide sources in rooms of different sizes

    Directory of Open Access Journals (Sweden)

    Khabaz Rahim

    2015-01-01

    Full Text Available Calibrations of neutron devices used in area monitoring are often performed by radionuclide neutron sources. Device readings increase due to neutrons scattered by the surroundings and the air. The influence of said scattering effects have been investigated in this paper by performing Monte Carlo simulations for ten different radionuclide neutron sources inside several sizes of concrete wall spherical rooms (Rsp = 200 to 1500 cm. In order to obtain the parameters that relate the additional contribution from scattered neutrons, calculations using a polynomial fit model were evaluated. Obtained results show that the contribution of scattering is roughly independent of the geometric shape of the calibration room. The parameter that relates the room-return scattering has been fitted in terms of the spherical room radius, so as to reasonably accurately estimate the scattering value for each radionuclide neutron source in any geometry of the calibration room.

  18. Neutron calibration field of bare {sup 252}Cf source in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Le, Ngoc Thiem; Tran, Hoai Nam; Nguyen, Khai Tuan [Institute for Nuclear Science and Technology, Hanoi (Viet Nam); Trinh, Glap Van [Institute of Research and Development, Duy Tan University, Da Nang (Viet Nam)

    2017-02-15

    This paper presents the establishment and characterization of a neutron calibration field using a bare {sup 252}Cf source of low neutron source strength in Vietnam. The characterization of the field in terms of neutron flux spectra and neutron ambient dose equivalent rates were performed by Monte Carlo simulations using the MCNP5 code. The anisotropy effect of the source was also investigated. The neutron ambient dose equivalent rates at three reference distances of 75, 125, and 150 cm from the source were calculated and compared with the measurements using the Aloka TPS-451C neutron survey meters. The discrepancy between the calculated and measured values is found to be about 10%. To separate the scattered and the direct components from the total neutron flux spectra, an in-house shadow cone of 10% borated polyethylene was used. The shielding efficiency of the shadow cone was estimated using the MCNP5 code. The results confirmed that the shielding efficiency of the shadow cone is acceptable.

  19. Self-Powered Neutron Detector Calibration Using a Large Vertical Irradiation Hole of HANARO

    OpenAIRE

    Kim Myong-Seop; Park Byung-Gun; Kang Gi-Doo

    2018-01-01

    A calibration technology of the self-powered neutron detectors (SPNDs) using a large vertical irradiation hole of HANARO is developed. The 40 Rh-SPNDs are installed on the polycarbonate plastic support, and the gold wires with the same length as the effective length of the rhodium emitter of the SPND are also installed to measure the neutron flux on the SPND. They are irradiated at a low reactor power, and the SPND current is measured using the pico-ammeter. The external gamma-rays which affe...

  20. Importance of the metrological network for calibration of neutron logging methods

    International Nuclear Information System (INIS)

    Rysavy, F.

    1995-01-01

    The calibration characteristics of neutron logging instrumentation are discussed. The principles of the rock, plastics, and water models are briefly outlined. Indian limestone of 9% porosity is the primary standard in the neutron logging metrology network, from which secondary standards employed during certification measurements are derived. It is recommended that rock blocks should be used as national standards, and each secondary institution should possess a set of polyethylene cylinders, one of which would serve as the main standard for the institution in question. (J.B.)

  1. Characterization of a diamond detector to be used as neutron yield monitor during the in-vessel calibration of JET neutron detectors in preparation of the DT experiment

    International Nuclear Information System (INIS)

    Pillon, Mario; Angelone, Maurizio; Batistoni, Paola; Loreti, Stefano; Milocco, Alberto

    2016-01-01

    Highlights: • A diamond detector has been characterized for use as neutron yield monitor of a portable 14 MeV neutron generator. • The system will be used for the 14 MeV calibration of JET neutron detector. • The results and the performances of the monitor are very satisfactory in term of accuracy and reliability. - Abstract: A new Deuterium-Tritium (DT) campaign is planned at JET. An accurate calibration for the 14 MeV neutron yield monitors is necessary. In order to perform the calibration a 14 MeV Neutron Generator with suitable intensity (∼10 8 n/s) will be used. Due to the intensity change during the Neutron Generator lifetime it would be necessary to monitor continuously the neutron emission intensity during the calibration using a compact detector attached to it. A high quality diamond detector has been chosen as one of the monitors. This detector has been fully characterized at the 14 MeV Frascati Neutron Generator facility. The characterization procedure and the resulting 14 MeV neutron response of the detector are described in this paper together with the obtained uncertainties.

  2. Characteristics and calibration of the transmission-type fast neutron moisture meter

    International Nuclear Information System (INIS)

    Banzai, K.

    1984-01-01

    With the Transmission-type Fast Neutron Moisture Meter, we did some experiments for calibration and the effective range of fast neutron scattering, and observed soil moisture process before and after making artificial rainfall at a lysimeter filled by decomposed granite. A fast neutron source of this meter is 252 Cf and capacity of 100 μ Ci. The neutron detector is NE-213 liquid scintilator which recovers a little flux of neutron source. For the customary thermal neutron meter, the effective range of neutron scattering is variable by soil moisture values surrounding the observation point, but this fast neutron, insert and transmission-type meter shows soil moisture in small capacity between a source and a detector. Experimental Results; 1) The calibration curve, calculated statistically from the relation of soil moisture and the count ratio in a 200 l drum packed with beads, gravel, sand and Kanto loam, became only one line. The correlation coefficient of this curve was 0.996 and the standard error was 1.94% with volumetric water content. 2) Count ratio started to decrease as observation point approached soil surface from the boundary of 6 cm depth in soil. Volumetric water content increased more than fact with the previous calibration curve. 3) We limited the detectable range to fast neutron, but a little scattering was seen surrounding the soil of a observation point. The effective range of horizontal scattering was a width of 20 cm with the center line connected between a source and a detector, with a circle of 5 cm diameter surrounding the source, and a circle of 10-15 cm diameter surrounding the detector. 4) Soil moisture before and after artificial rainfall was observed with this meter and by the measurement of a 100 cm 3 oven dried sampling vessel. Volumetric water content by the latter measurement, was more variable because sampling points were at a distance from the center of observation site and sampling technique was bad. Otherwise soil moisture values

  3. Etude de la diagraphie neutron du granite de Beauvoir. Effet neutron des altérations et de la matrice du granite. Calibration granite. Porosité totale à l'eau et porosité neutron Analysis of the Beauvoir Granite Neutron Log. Neutron Effect of Alterations and of the Granite Matrix. Granite Calibration. Total Water Porosity and Neutron Porosity

    Directory of Open Access Journals (Sweden)

    Galle C.

    2006-11-01

    Full Text Available Cet article rend compte des travaux effectués sur la porosité du granite de Beauvoir (Sondage GPF 1 d'Echassières, Massif Central français. L'objectif de notre étude est de pouvoir obtenir des valeurs représentatives de la saturation en eau (porosité totale à l'eau n du granite de Beauvoir à partir des mesures de porosité neutron PorositéN (diagraphie neutron BRGM sans avoir recours aux mesures sur carottes. Notre démarche est expérimentale et nous avons tenté d'approfondir certains problèmes liés à l'utilisation de la diagraphie neutron dans une roche granitique. Deux facteurs principaux conditionnent la réponse neutron : la concentration en hydrogène de la formation (eau libre et eau de constitution de certains minéraux et la présence d'éléments absorbeurs à forte section de capture comme le gadolinium, le cadmium, le bore, . . . et dans le cas du granite de Beauvoir, le lithium. A partir des mesures de porosité totale à l'eau n sur carottes, des essais de pertes au feu sur poudre qui nous permettent de déterminer la porosité neutron liée à l'eau de constitution PorositéN(OH- et des analyses chimiques avec lesquelles nous évaluons la porosité neutron thermique PorositéN(ox (Programme SNUPAR, Schlumberger liée à la capture neutronique, nous reconstituons la porosité neutron totale PorositéNR du granite de Beauvoir. Pour 7 échantillons caractéristiques du granite de Beauvoir, nous réalisons grâce à ces résultats une nouvelle calibration du taux de comptage neutron initial corrigé du gradient thermique et de l'effet de trou. Grâce à cette opération, il est possible de déterminer, pour les échantillons traités, la porosité neutron du granite avec une calibration granite (PorositéNg et non calcaire (PorositéNc. La connaissance de l'effet neutron de la matrice nous permet enfin d'évaluer la teneur en eau du granite (porosité totale à l'eau et de comparer celle-ci avec la porosité mesurée sur

  4. Field calibration of PADC track etch detectors for local neutron dosimetry in man using different radiation qualities

    Energy Technology Data Exchange (ETDEWEB)

    Haelg, Roger A., E-mail: rhaelg@phys.ethz.ch [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Besserer, Juergen [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Boschung, Markus; Mayer, Sabine [Division for Radiation Safety and Security, Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Clasie, Benjamin [Department of Radiation Oncology, Massachusetts General Hospital, 30 Fruit Street, Boston, MA 02114 (United States); Kry, Stephen F. [Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Schneider, Uwe [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 204, CH-8057 Zurich (Switzerland)

    2012-12-01

    In order to quantify the dose from neutrons to a patient for contemporary radiation treatment techniques, measurements inside phantoms, representing the patient, are necessary. Published reports on neutron dose measurements cover measurements performed free in air or on the surface of phantoms and the doses are expressed in terms of personal dose equivalent or ambient dose equivalent. This study focuses on measurements of local neutron doses inside a radiotherapy phantom and presents a field calibration procedure for PADC track etch detectors. An initial absolute calibration factor in terms of H{sub p}(10) for personal dosimetry is converted into neutron dose equivalent and additional calibration factors are derived to account for the spectral changes in the neutron fluence for different radiation therapy beam qualities and depths in the phantom. The neutron spectra used for the calculation of the calibration factors are determined in different depths by Monte Carlo simulations for the investigated radiation qualities. These spectra are used together with the energy dependent response function of the PADC detectors to account for the spectral changes in the neutron fluence. The resulting total calibration factors are 0.76 for a photon beam (in- and out-of-field), 1.00 (in-field) and 0.84 (out-of-field) for an active proton beam and 1.05 (in-field) and 0.91 (out-of-field) for a passive proton beam, respectively. The uncertainty for neutron dose measurements using this field calibration method is less than 40%. The extended calibration procedure presented in this work showed that it is possible to use PADC track etch detectors for measurements of local neutron dose equivalent inside anthropomorphic phantoms by accounting for spectral changes in the neutron fluence.

  5. Calibration, checking and physical corrections for a new dual-spaced neutron porosity tool

    International Nuclear Information System (INIS)

    Smith, M.P.

    1986-01-01

    A new dual-spaced neutron tool has been developed that features high count rates and improved statistical precision and log repeatability. Environmental corrections including borehole diameter, standoff, and lithology are at acceptable levels for DSN-II. The effects of varying source-to-detector spacings and shielding are summarized. Porosity measurement resolution and statistical precision are discussed and it is indicated how tradeoffs between higher count rates and increased environmental corrections must be considered. The absolute calibration of a standard tool is based on its response to limestone test pits, field data, and theoretical calculations. Test data for actual manufactured tools are presented. Shop calibration and wellsite check procedures are discussed. The advantages of multiposition check operations are explained, including reduced sensitivity to check block positioning and external environment. An analysis is presented of errors from tool manufacturing, calibration, and check procedures. A generalized theory of neutron scattering and absorption has been developed to correct dual-spaced neutron logs for unusual minerals and fluids

  6. A new expression for determination of fluences from a spherical moderator neutron source for the calibration of spherical neutron measuring devices

    International Nuclear Information System (INIS)

    Khoshnoodi, M.; Sohrabi, M.

    1997-01-01

    A new expression modifying the inverse square law for determination of neutron fluences from spherical moderator neutron sources is reported. The formalism is based on the neutron fluence at a point outside the moderator as the summation of fluxes of two groups of neutrons: direct neutrons from the central region of the moderator, and moderated neutrons which, to a first approximation, are scattered from the outermost layers of the spherical moderator. The expression has been further developed for spherical neutron measuring devices with an appropriate geometry factor which corrects the reading of the device for non-uniform irradiation of the detector. The combination of the new fluence function and those of the air and room scattered components introduce a calibration model. The fluence relationship obtained for moderated sources may conveniently be used for calculating the more rapid change of neutron dose at close distances than that which is based on the inverse square dependence. (author)

  7. Bayesian calibration of reactor neutron flux spectrum using activation detectors measurements: Application to CALIBAN reactor

    Energy Technology Data Exchange (ETDEWEB)

    Cartier, J. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, DIF, F-91297 Arpajon (France); Casoli, P. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, Valduc, F-21120 Is sur Tille (France); Chappert, F. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, DIF, F-91297 Arpajon (France)

    2013-07-01

    In this paper, we present calibration methods in order to estimate reactor neutron flux spectrum and its uncertainties by using integral activation measurements. These techniques are performed using Bayesian and MCMC framework. These methods are applied to integral activation experiments in the cavity of the CALIBAN reactor. We estimate the neutron flux and its related uncertainties. The originality of this work is that these uncertainties take into account measurements uncertainties, cross-sections uncertainties and model error. In particular, our results give a very good approximation of the total flux and indicate that neutron flux from MCNP simulation for energies above about 5 MeV seems to overestimate the 'real flux'. (authors)

  8. On the absolute calibration of a DT fusion neutron yield diagnostic

    Directory of Open Access Journals (Sweden)

    Ruiz C.L.

    2013-11-01

    Full Text Available Recent advances in Inertial Confinement Fusion (ICF experiments at Lawrence Livermore National Laboratory's National Ignition Facility (NIF have underscored the need for accurate total yield measurements of DT neutrons because yield measurements provide a measure of the predicted performance of the experiments. Future gas-puff DT experiments at Sandia National Laboratory's Z facility will also require similar measurements. For ICF DT experiments, the standard technique for measuring the neutron (14.1 MeV yield, counts the activity (counts/minute induced in irradiated copper samples. This activity occurs by the 63Cu(n,2n62Cu reaction where 62Cu decays by positrons (β+ with a half-life of 9.67 minutes. The calibrations discussed here employ the associated-particle method (APM, where the α (4He particles from the T(d,n4He reaction are measured to infer neutron fluxes on a copper sample. The flux induces 62Cu activity, measured in a coincidence counting system. The method leads to a relationship between a DT neutron yield and copper activity known as the F-factor. The goal in future experiments is to apply this calibration to measure the yield at NIF with a combined uncertainty approaching 5%.

  9. Effects of gypsum and bulk density on neutron probe calibration curves

    International Nuclear Information System (INIS)

    Arslan, Awadis; Razzouk, A.K.

    1993-10-01

    The effects of gypsum and bulk density on the neutron probe calibration curve were studied in the laboratory and in the field. The effect of bulk density was negligible for the soil studied in the laboratory, while it was significant for the field calibration. An increase in the slope of moisture content on a volume basis vs. count ratio with increasing gypsum content at the soil was observed in the laboratory calibration. A simple method for correction of the calibration curve for gypsum content was adopted to obtain a specific curve for each layer. The adapted method requires the gypsum fraction to be estimated for each layer and then incorporated in the calibration curve to improve the coefficient of determination. A field calibration showed an improvement of the determination coefficient by introducing bulk density and gypsum fraction, in addition to count ratio using moisture content on a volume basis as a dependent variable in multi linear regression analysis. The same procedure was successful with variable gravel fractions. (author). 18 refs., 3 figs., 2 tabs

  10. Monte Carlo efficiency calibration of a neutron generator-based total-body irradiator

    International Nuclear Information System (INIS)

    Shypailo, R.J.; Ellis, K.J.

    2009-01-01

    Many body composition measurement systems are calibrated against a single-sized reference phantom. Prompt-gamma neutron activation (PGNA) provides the only direct measure of total body nitrogen (TBN), an index of the body's lean tissue mass. In PGNA systems, body size influences neutron flux attenuation, induced gamma signal distribution, and counting efficiency. Thus, calibration based on a single-sized phantom could result in inaccurate TBN values. We used Monte Carlo simulations (MCNP-5; Los Alamos National Laboratory) in order to map a system's response to the range of body weights (65-160 kg) and body fat distributions (25-60%) in obese humans. Calibration curves were constructed to derive body-size correction factors relative to a standard reference phantom, providing customized adjustments to account for differences in body habitus of obese adults. The use of MCNP-generated calibration curves should allow for a better estimate of the true changes in lean tissue mass that many occur during intervention programs focused only on weight loss. (author)

  11. Development, improvement and calibration of neutronic reaction rates measurements: elaboration of a standard techniques basis

    International Nuclear Information System (INIS)

    Hudelot, J.P.

    1998-06-01

    In order to improve and to validate the neutronics calculation schemes, perfecting integral measurements of neutronics parameters is necessary. This thesis focuses on the conception, the improvement and the development of neutronics reaction rates measurements, and aims at building a base of standard techniques. Two subjects are discussed. The first one deals with direct measurements by fission chambers. A short presentation of the different usual techniques is given. Then, those last ones are applied through the example of doubling time measurements on the EOLE facility during the MISTRAL 1 experimental programme. Two calibration devices of fission chambers are developed: a thermal column located in the central part of the MINERVE facility, and a calibration cell using a pulsed high flux neutron generator and based on the discrimination of the energy of the neutrons with a time-of-flight method. This second device will soon allow to measure the mass of fission chambers with a precision of about 1 %. Finally, the necessity of those calibrations will be shown through spectral indices measurements in core MISTRAL 1 (UO 2 ) and MISTRAL 2 (MOX) of the EOLE facility. In each case, the associated calculation schemes, performed using the Monte Carlo MCNP code with the ENDF-BV library, will be validated. Concerning the second one, the goal is to develop a method for measuring the modified conversion ratio of 238 U (defined as the ratio of 238 U capture rate to total fission rate) by gamma-ray spectrometry of fuel rods. Within the framework of the MISTRAL 1 and MISTRAL 2 programmes, the measurement device, the experimental results and the spectrometer calibration are described. Furthermore, the MCNP calculations of neutron self-shielding and gamma self-absorption are validated. It is finally shown that measurement uncertainties are better than 1 %. The extension of this technique to future modified conversion ratio measurements for 242 Pu (on MOX rods) and 232 Th (on

  12. Development, improvement and calibration of neutronic reaction rate measurements: elaboration of a base of standard techniques

    International Nuclear Information System (INIS)

    Hudelot, J.P.

    1998-01-01

    In order to improve and to validate the neutronic calculation schemes, perfecting integral measurements of neutronic parameters is necessary. This thesis focuses on the conception, the improvement and the development of neutronic reaction rates measurements, and aims at building a base of standard techniques. Two subjects are discussed. The first one deals with direct measurements by fission chambers. A short presentation of the different usual techniques is given. Then, those last ones are applied through the example of doubling time measurements on the EOLE facility during the MISTRAL 1 experimental programme. Two calibration devices of fission chambers are developed: a thermal column located in the central part of the MINERVE facility, and a calibration cell using a pulsed high flux neutron generator and based on the discrimination of the energy of the neutrons with a time-of-flight method. This second device will soon allow to measure the mass of fission chambers with a precision of about 1 %. Finally, the necessity of those calibrations will be shown through spectral indices measurements in core MISTRAL 1 (UO 2 ) and MISTRAL 2 (MOX) of the EOLE facility. In each case, the associated calculation schemes, performed using the Monte Carlo MCNP code with the ENDF-BV library, will be validated. Concerning the second one, the goal is to develop a method for measuring the modified conversion ratio of 238 U (defined as the ratio of 238 U capture rate to total fission rate) by gamma-ray spectrometry of fuel rods. Within the framework of the MISTRAL 1 and MISTRAL 2 programmes, the measurement device, the experimental results and the spectrometer calibration are described. Furthermore, the MCNP calculations of neutron self-shielding and gamma self-absorption are validated. It is finally shown that measurement uncertainties are better than 1 %. The extension of this technique to future modified conversion ratio measurements for 242 Pu (on MOX rods) and 232 Th (on Thorium

  13. Calibration of a large multi-element neutron counter in the energy range 85-430 MeV

    CERN Document Server

    Strong, J A; Esterling, R J; Garvey, J; Green, M G; Harnew, N; Jane, M R; Jobes, M; Mawson, J; McMahon, T; Robertson, A W; Thomas, D H

    1978-01-01

    Describes the calibration of a large 60 element neutron counter with a threshold of 2.7 MeV equivalent electron energy. The performance of the counter has been measured in the neutron kinetic energy range 8.5-430 MeV using a neutron beam at the CERN Synchrocyclotron. The results obtained for the efficiency as a function of energy are in reasonable agreement with a Monte Carlo calculation. (7 refs).

  14. Calibration of thermal neutron detection compound BN-1 and CR-39 in the exposure room of Triga Reactor in Ljubljana

    International Nuclear Information System (INIS)

    Kristof, E.; Ilic, R.; Skvarc, J.; Dijanosic, R.

    1994-01-01

    Description of determination of thermal neutron fluences in the range from 1.E+02 to 1.E+12 cm -2 for calibration of the neutron sensitive compound consisting of the neutron converter BN-1 and charged particle detector CR-39 is given. The method employs two proportional BF3 detectors supplemented by a Ge(Li) gamma spectometer utilizing gold foils. The results of the measurements are also presented. (author)

  15. Calibration of the proton detector used for the neutron life time experiment τSPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Kim; Haack, Jan; Heil, Werner; Karch, Jan [Johannes Gutenberg-Universitaet Mainz (Germany); Beck, Marcus [Johannes Gutenberg-Universitaet Mainz (Germany); Helmholtz-Institut Mainz (Germany)

    2016-07-01

    In order to measure the lifetime of free neutrons, a decay curve will be measured by detecting the decay products proton and electron. Their energies range up to 750 eV (protons) respectively 780 keV (electrons). The protons are accelerated onto 15 keV, in order to pass the dead layer of the detector and to be distinguishable from electronic noise. For the measurement a silicon drift detector is used which needs to be calibrated. This is achieved with a {sup 133}Ba source mounted on three source holders of different materials in a vacuum chamber. Thus not only four of the characteristic lines of the {sup 133}Ba source were measured but also the characteristic lines of the three source holders which yield four more calibration lines in the area of the proton energy in the spectrum. We report the implementation and results of the calibration of the silicon drift detector used for the neutron lifetime measurement τSPECT.

  16. Construction of 144, 565 keV and 5.0 MeV monoenergetic neutron calibration fields at JAERI.

    Science.gov (United States)

    Tanimura, Y; Yoshizawa, M; Saegusa, J; Fujii, K; Shimizu, S; Yoshida, M; Shibata, Y; Uritani, A; Kudo, K

    2004-01-01

    Monoenergetic neutron calibration fields of 144, 565 keV and 5.0 MeV have been developed at the Facility of Radiation Standards of JAERI using a 4 MV Pelletron accelerator. The 7Li(p,n)7Be and 2H(d,n)3He reactions are employed for neutron production. The neutron energy was measured by the time-of-flight method with a liquid scintillation detector and calculated with the MCNP-ANT code. A long counter is employed as a neutron monitor because of the flat response. The monitor is set up where the influence of inscattered neutrons from devices and their supporting materials at a calibration point is as small as possible. The calibration coefficients from the monitor counts to the neutron fluence at a calibration point were obtained from the reference fluence measured with the transfer instrument of the primary standard laboratory (AIST), a 24.13 cm phi Bonner sphere counter. The traceability of the fields to AIST was established through the calibration.

  17. Reference neutron radiations. Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field

    International Nuclear Information System (INIS)

    2000-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 2. of ISO 8529 takes as its starting point the neutron sources described in ISO 8529-1. It specifies the procedures to be used for realizing the calibration conditions of radiation protection devices in neutron fields produced by these calibration sources, with particular emphasis on the corrections for extraneous effects (e.g., the neutrons scattered from the walls of the calibration room). In this part of ISO 8529, particular emphasis is placed on calibrations using radionuclide sources (clauses 4 to 6) due to their widespread application, with less details given on the use of accelerator and reactor sources (8.2 and 8.3). This part of ISO 8529 then leads to ISO 8529-3 which gives conversion coefficients and the general rules and procedures for calibration

  18. Evaluation of influence by room-scattered neutrons and source-to-phantom geometrical effect for calibration of personal neutron dosemeters

    International Nuclear Information System (INIS)

    Yoshida, Tadayoshi; Tsujimura, Norio

    2005-01-01

    Correction for the influence of room-scattered neutrons in irradiation rooms is essential in the case of calibrating neutron dosemeters. The ISO8529-2 recommends some correction method such as the shadow-cone method and the generalized-fit method for the calibration of neutron ambient dose equivalent (rate) meters. However, the ISO standard does not describe the correction methods for personal neutron dosemeters in detail. The authors investigated the variation of responses of neutron detectors mounted on phantom as a function of source-to-phantom distance, and discussed the applicability of the shadow-cone method and generalized-fit method for calibrating personal neutron dosemeters. The measurements were carried out using 3 He and hydrogen-filled proportional counters as surrogates of albedo and recoil-proton type dosemeters, respectively, at different distances ranging from 30 cm to 400 cm. As a result, it was clarified that both correction methods are applicable for recoil-proton type detectors over any distance. Contrarily, for albedo-type detectors, the variation of response does not follow the curve predicted from the generalized fit method at distances smaller than 70 cm. This result strongly suggests that the correction for source-to-phantom geometry effect should be made for calibrating albedo-type detectors at smaller distances. (author)

  19. Improving calibration and validation of cosmic-ray neutron sensors in the light of spatial sensitivity

    Directory of Open Access Journals (Sweden)

    M. Schrön

    2017-10-01

    Full Text Available In the last few years the method of cosmic-ray neutron sensing (CRNS has gained popularity among hydrologists, physicists, and land-surface modelers. The sensor provides continuous soil moisture data, averaged over several hectares and tens of decimeters in depth. However, the signal still may contain unidentified features of hydrological processes, and many calibration datasets are often required in order to find reliable relations between neutron intensity and water dynamics. Recent insights into environmental neutrons accurately described the spatial sensitivity of the sensor and thus allowed one to quantify the contribution of individual sample locations to the CRNS signal. Consequently, data points of calibration and validation datasets are suggested to be averaged using a more physically based weighting approach. In this work, a revised sensitivity function is used to calculate weighted averages of point data. The function is different from the simple exponential convention by the extraordinary sensitivity to the first few meters around the probe, and by dependencies on air pressure, air humidity, soil moisture, and vegetation. The approach is extensively tested at six distinct monitoring sites: two sites with multiple calibration datasets and four sites with continuous time series datasets. In all cases, the revised averaging method improved the performance of the CRNS products. The revised approach further helped to reveal hidden hydrological processes which otherwise remained unexplained in the data or were lost in the process of overcalibration. The presented weighting approach increases the overall accuracy of CRNS products and will have an impact on all their applications in agriculture, hydrology, and modeling.

  20. Neutron Gauge Calibration Curve as Affected by Chloride Concentration and Bulk Density of Loam Soil

    International Nuclear Information System (INIS)

    AL-Hasani, A.A.; Fahad, A.A.; Shihab, R.M.

    2010-01-01

    chloride concentration and bulk density are considered among important factors affecting calibration curve of neutron gauge in the soil.The aim of this study was to investigate the effect of chloride concentration and bulk density of a loam soil on neutron gauge calibration curve.Sufficient amount of loam soil was air dried screened through a 2 mm sieve,and divided into three equal portions.Sodium chloride of 2.5 and 6.6g kg'-1 soil was added to the first and second portions,respectively.The third portion was left as a control.The soil then moistened and mixed well to make volumetric water content within the range of 0.01 to 0.24 cm 3 cm - 3. The moist soil was packed into an iron drum 0.80 m diameter and 1.00 m height to obtain bulk densities of 1.10 and 1.30 to 1.60 Mg m - 3 for uncompacted soil,respectively.Access tube 0.05 m inner diameter was installed in the center of the drum.Three readings from CPN 503 neutron gauge were taken at each 0.15,0.30, 0.45,and 0.75 m depth.Results indicated that the count (counts/standard count) for an aqueous solution decreased with the increase in chloride concentration.Similarly, the slope of the linear calibration curves of the investigated soil decreased with the increase in chloride concentration.Shifting of the curves was 9 to 10%for the uncompacted soil, whereas it was 12 to 14 % for the compacted of low and high concentration of chloride, respectively . Results of changing bulk density always reduced the slope value as compared with the uncorrected count ratio.

  1. Improving calibration and validation of cosmic-ray neutron sensors in the light of spatial sensitivity

    Science.gov (United States)

    Schrön, Martin; Köhli, Markus; Scheiffele, Lena; Iwema, Joost; Bogena, Heye R.; Lv, Ling; Martini, Edoardo; Baroni, Gabriele; Rosolem, Rafael; Weimar, Jannis; Mai, Juliane; Cuntz, Matthias; Rebmann, Corinna; Oswald, Sascha E.; Dietrich, Peter; Schmidt, Ulrich; Zacharias, Steffen

    2017-10-01

    In the last few years the method of cosmic-ray neutron sensing (CRNS) has gained popularity among hydrologists, physicists, and land-surface modelers. The sensor provides continuous soil moisture data, averaged over several hectares and tens of decimeters in depth. However, the signal still may contain unidentified features of hydrological processes, and many calibration datasets are often required in order to find reliable relations between neutron intensity and water dynamics. Recent insights into environmental neutrons accurately described the spatial sensitivity of the sensor and thus allowed one to quantify the contribution of individual sample locations to the CRNS signal. Consequently, data points of calibration and validation datasets are suggested to be averaged using a more physically based weighting approach. In this work, a revised sensitivity function is used to calculate weighted averages of point data. The function is different from the simple exponential convention by the extraordinary sensitivity to the first few meters around the probe, and by dependencies on air pressure, air humidity, soil moisture, and vegetation. The approach is extensively tested at six distinct monitoring sites: two sites with multiple calibration datasets and four sites with continuous time series datasets. In all cases, the revised averaging method improved the performance of the CRNS products. The revised approach further helped to reveal hidden hydrological processes which otherwise remained unexplained in the data or were lost in the process of overcalibration. The presented weighting approach increases the overall accuracy of CRNS products and will have an impact on all their applications in agriculture, hydrology, and modeling.

  2. CR-39 nuclear track detector used for neutron dosimetry: system calibration

    International Nuclear Information System (INIS)

    Saint Martin, G.; Lopez, F.; Bernaola, Omar A.

    2009-01-01

    Stacks composed by 1 mm thickness CR-39 foils and polyethylene and PVC films were evaluated to be used as neutron dosemeters. Irradiations were made with a calibrated 241 Am-Be source in a dose range from 0 to 3.1 mSv and the etching conditions were optimized. The measurements of number of tracks per surface unit in the CR-39 detectors showed a good linear behaviour as a function of the dose. The minimum detectable dose equivalent (MDDE) was calculated. (author)

  3. WHITE COLLAR CRIME - Investigations

    OpenAIRE

    Nyagudi, Nyagudi Musandu

    2014-01-01

    WHITE COLLAR CRIME - Investigations Presentation By  Dr. Nyagudi MusanduForensic Criminologist 2nd International Securityand Safety Conference and Exhibition, 16th April, 2010 a forum hosted by Events Management Solutions at the Sarit Centre, Nairobi, Kenya  

  4. Calibration of neutron moisture gauges and their ability to spatially determine soil water content in environmental studies

    International Nuclear Information System (INIS)

    Nyhan, J.W.; Martinez, J.L.; Langhorst, G.J.

    1994-10-01

    Several neutron moisture gauges were calibrated, and their ability to spatially determine soil water content was evaluated. In 1982, the midpoint of sensitivity of each neutron probe to the detection of hydrogen was determined, as well as the radius of investigation of each probe in crushed Bandelier Tuff with varying water contents. After determining the response of one of the moisture gauges to changes in soil water at the soil-air interface, a neutron transport model was successfully calibrated to predict spatial variations in soil water content. The model was then used to predict various shapes and volumes of crushed Bandelier Tuff interrogated by the neutron moisture gauge. From 1991 through 1994, six neutron moisture gauges were calibrated for soil water determinations in a local topsoil and crushed Bandelier Tuff, as well as for a sample of fine sand and soils from a field experiment at Hill Air Force Base. Statistical analysis of the calibration results is presented and summarized, and a final summary of practical implications for future neutron moisture gauge studies at Los Alamos is included

  5. Study for correction of neutron scattering in the calibration of the albedo individual monitor from the Neutron Laboratory (LN), IRD/CNEN-RJ, Brazil

    International Nuclear Information System (INIS)

    Freitas, B.M.; Silva, A.X. da

    2014-01-01

    The Instituto de Radioprotecao e Dosimetria (IRD) runs a neutron individual monitoring service with albedo type monitor and thermoluminescent detectors (TLD). Moreover the largest number of workers exposed to neutrons in Brazil is exposed to 241 Am-Be fields. Therefore a study of the response of albedo dosemeter due to neutron scattering from 241 Am-Be source is important for a proper calibration. In this work, it has been evaluated the influence of the scattering correction in two distances at the Low Scattering Laboratory of the Neutron Laboratory of the Brazilian National Laboratory (Lab. Nacional de Metrologia Brasileira de Radiacoes Ionizantes) in the calibration of that albedo dosemeter for a 241 Am-Be source. (author)

  6. Calibration of PADC-based neutron area dosemeters in the neutron field produced in the treatment room of a medical LINAC

    International Nuclear Information System (INIS)

    Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; García-Fusté, M.J.; San-Pedro, M. de; Tana, L.; D’Errico, F.; Ciolini, R.; Di Fulvio, A.

    2013-01-01

    PADC-based nuclear track detectors have been widely used as convenient ambient dosemeters in many working places. However, due to the large energy dependence of their response in terms of ambient dose equivalent (H ∗ (10)) and to the diversity of workplace fields in terms of energy distribution, the appropriate calibration of these dosemeters is a delicate task. These are among the reasons why ISO has introduced the 12789 Series of Standards, where the simulated workplace neutron fields are introduced and their use to calibrate neutron dosemeters is recommended. This approach was applied in the present work to the UAB PADC-based nuclear track detectors. As a suitable workplace, the treatment room of a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa), was chosen. Here the neutron spectra in two points of tests (1.5 m and 2 m from the isocenter) were determined with the INFN-LNF Bonner Sphere Spectrometer equipped with Dysprosium activation foils (Dy-BSS), and the values of H ∗ (10) were derived on this basis. The PADC dosemeters were exposed in these points. Their workplace specific H*(10) responses were determined and compared with those previously obtained in different simulated workplace or reference (ISO 8529) neutron fields. - Highlights: ► The neutron field of a medical LINAC was used to calibrate PADC neutron dosemeters. ► The neutron spectra were derived with a Dy-foil based Bonner Sphere Spectrometer. ► Workplace specific calibration factor were derived for the PADC dosemeters. ► These factors were compared with those obtained in reference neutron fields

  7. Beyond Californium-A Neutron Generator Alternative for Dosimetry and Instrument Calibration in the U.S.

    Science.gov (United States)

    Piper, Roman K; Mozhayev, Andrey V; Murphy, Mark K; Thompson, Alan K

    2017-09-01

    Evaluations of neutron survey instruments, area monitors, and personal dosimeters rely on reference neutron radiations, which have evolved from the heavy reliance on (α,n) sources to a shared reliance on (α,n) and the spontaneous fission neutrons of californium-252 (Cf). Capable of producing high dose equivalent rates from an almost point source geometry, the characteristics of Cf are generally more favorable when compared to the use of (α,n) and (γ,n) sources or reactor-produced reference neutron radiations. Californium-252 is typically used in two standardized configurations: unmoderated, to yield a fission energy spectrum; or with the capsule placed within a heavy-water moderating sphere to produce a softened spectrum that is generally considered more appropriate for evaluating devices used in nuclear power plant work environments. The U.S. Department of Energy Cf Loan/Lease Program, a longtime origin of affordable Cf sources for research, testing and calibration, was terminated in 2009. Since then, high-activity sources have become increasingly cost-prohibitive for laboratories that formerly benefited from that program. Neutron generators, based on the D-T and D-D fusion reactions, have become economically competitive with Cf and are recognized internationally as important calibration and test standards. Researchers from the National Institute of Standards and Technology and the Pacific Northwest National Laboratory are jointly considering the practicality and technical challenges of implementing neutron generators as calibration standards in the U.S. This article reviews the characteristics of isotope-based neutron sources, possible isotope alternatives to Cf, and the rationale behind the increasing favor of electronically generated neutron options. The evaluation of a D-T system at PNNL has revealed characteristics that must be considered in adapting generators to the task of calibration and testing where accurate determination of a dosimetric quantity is

  8. Neutron flux measurement and thermal power calibration of the IAN-R1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sarta Fuentes, Jose A.; Castiblanco Bohorquez, Luis A

    2008-10-29

    The IAN-R1 TRIGA reactor in Colombia was initially fueled with MTR-HEU enriched to 93% U-235, operated since 1965 at 10 kW, and was upgraded to 30 kW in 1980. General Atomics achieved in 1997 the conversion of HEU fuel to LEU fuel TRIGA type, and upgraded the reactor power to 100 kW. Since the IAN-R1 TRIGA reactor was in an extended shutdown during seven years, it was necessary to repeat some results of the commissioning test conducted in 1997. The thermal power calibration was carried out using the calorimetric method. The reactor was operated approximately at 20 kW during 3.5 hours, with manual power corrections since the automatic control system failed and with the forced refrigeration off. During the calorimetric experiment, the pool temperature was measured with a RTD which is installed near to the core. The dates were collected in intervals of 30 minutes. For establishing thermal power reactor, the water temperature versus the running were registered. For a calculated tank volume of 16 m{sup 3}, the tank constant calculated for the IAN-R1 TRIGA reactor is 0.0539 C/kW-hr. The reactor power determined was 19 kW. The core configuration is a rectangular grid plate that holds a combination of 4-rod and 3-rod clusters. The core contains 50 fuel rods with LEU fuel TRIGA (UZr H1.6) type enriched to 19.7%. The radial reflector consists of twenty graphite elements six of which are used for isotope production. The top an bottom reflectors are the cylindrical graphite end reflectors which are installed above and below of the active fuel section in each fuel rod. The spatial dependence of thermal neutron flux was measured axially in the 3-rod clusters 4C, 3D, 5E and in the 4F graphite element. The spatial distribution of the thermal neutron was determined using a self-powered detector and the absolute value of thermal neutron flux was determined by a gold activation detector. The (n, b- ) reaction is applied to determine the relative spatial distribution of thermal

  9. Absolute calibration system of neutron sources by the manganese sulphate bath

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Sachett, I.A.

    1990-01-01

    The calibration system consists of deep the neutron source, protected by plastic container, at the center of spherical polietilene tank, in a concentrated solution of manganese sulphate. The neutrons emitted by the source are moderated and when reach the termal energy are catched by manganese atoms activating the solution. After the saturation activity has been reached the source is removed and one scintilation detector (NaI(Tl) 3' x 3') is put in the same place to follow the decay activity. The gama couting rate (845 KeV 54 Mn photopeak), after the corrections is used to estimate the saturation activity, and calculate the neutron source emission rate. These calculations are executed by one computer program. The uncertainties in the final value of emission rate are about 2.5 - 3.0 % to AmBe sources in the 1.11 x 10 10 Bq (0,3 Ci) - 3.7 x 10 11 Bq (10 Ci) range. (author) [pt

  10. Production and characterization of 228Th calibration sources with low neutron emission for GERDA

    Science.gov (United States)

    Baudis, L.; Benato, G.; Carconi, P.; Cattadori, C.; De Felice, P.; Eberhardt, K.; Eichler, R.; Petrucci, A.; Tarka, M.; Walter, M.

    2015-12-01

    The GERDA experiment at the Laboratori Nazionali del Gran Sasso (LNGS) searches for the neutrinoless double beta decay of 76Ge. In view of the GERDA Phase II data collection, four new 228Th radioactive sources for the calibration of the germanium detectors enriched in 76Ge have been produced with a new technique, leading to a reduced neutron emission rate from (α, n) reactions. The gamma activities of the sources were determined with a total uncertainty of ~4% using an ultra-low background HPGe detector operated underground at LNGS. The neutron emission rate was determined using a low background LiI(Eu) detector and a 3He counter at LNGS. In both cases, the measured neutron activity is ~10-6 n/(sṡBq), with a reduction of about one order of magnitude with respect to commercially available 228Th sources. Additionally, a specific leak test with a sensitivity to leaks down to ~10 mBq was developed to investigate the tightness of the stainless steel capsules housing the sources after their use in cryogenic environment.

  11. Neutron calibration facility with an Am-Be source for pulse shape discrimination measurement of CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Lee, H.S.; Bhang, H.; Choi, J.H.; Choi, S.; Joo, H.W.; Kim, G.B.; Kim, K.W.; Kim, S.C.; Kim, S.K.; Lee, J.H.; Lee, J.K.; Myung, S.S.; Hahn, I.S.; Jeon, E.J.; Kang, W.G.; Kim, Y.D.; Kim, Y.H.; Li, J.; Kim, H.J.; Leonard, D.S.

    2014-01-01

    We constructed a neutron calibration facility based on a 300-mCi Am-Be source in conjunction with a search for weakly interacting massive particle candidates for dark matter. The facility is used to study the response of CsI(Tl) crystals to nuclear recoils induced by neutrons from the Am-Be source and comparing them with the response to electron recoils produced by Compton scattering of 662-keV γ-rays from a 137 Cs source. The measured results on pulse shape discrimination (PSD) between nuclear- and electron-recoil events are quantified in terms of quality factors. A comparison with our previous result from a neutron generator demonstrate the feasibility of performing calibrations of PSD measurements using neutrons from a Am-Be source

  12. Mathematical model and computer programme for theoretical calculation of calibration curves of neutron soil moisture probes with highly effective counters

    International Nuclear Information System (INIS)

    Kolev, N.A.

    1981-07-01

    A mathematical model based on the three group theory for theoretical calculation by means of computer of the calibration curves of neutron soil moisture probes with highly effective counters, is described. Methods for experimental correction of the mathematical model are discussed and proposed. The computer programme described allows the calibration of neutron probes with high or low effective counters, and central or end geometry, with or without linearizing of the calibration curve. The use of two calculation variants and printing of output data gives the possibility not only for calibration, but also for other researches. The separate data inputs for soil and probe temperature allow the temperature influence analysis. The computer programme and calculation examples are given. (author)

  13. Calibration of A Prompt Gamma Neutron Activation Analysis (PGNAA) Facility: Experience at the Oregon State University TRIGA Reactor

    International Nuclear Information System (INIS)

    Norlida Yussup

    2011-01-01

    A prompt gamma neutron activation analysis (PGNAA) facility at Oregon State University (OSU) TRIGA reactor has been built in year 2008 and been operated since then. PGNAA is a technique used to determine the presence and quantity of trace elements such as boron, hydrogen and carbon which are more difficult to detect with other neutron analysis method. A calibration is essential to ensure the system works as required and the output is valid and reliable. The calibration was carried out by using Standard Reference Material (SRM). Besides, background data was also acquired for comparisons and analysis. The results are analyzed and discussed in this paper. (author)

  14. Calibration of area monitors for neutrons used in clinical linear accelerators; Calibracao de monitores de area para neutrons usados em aceleradores lineares clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Ana Paula; Pereira, Walsan Wagner; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da, E-mail: asalgado@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Batista, Delano V.S. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This work demonstrates the complexity and the necessary cares for the realization of measurements of neutron fields in rooms for radiotherapy treatment containing clinical accelerators. The acquaintance of the technical characteristics of the monitors and the periodic calibration are actions and fundamental procedures to guarantee traceability and the reliability of measurements

  15. Experimental evaluation of scattered thermal neutrons from various jig materials for use in fixing detectors for the calibration

    International Nuclear Information System (INIS)

    Shimizu, Shigeru; Yoshizawa, Michio

    2000-05-01

    Some jigs to fix detectors are used when radiation measuring instruments are calibrated or reference fluence rates are measured in thermal neutron irradiation fields. In this case, scattered thermal neutrons from the jigs, in particular, which contain hydrogenous materials, may affect the results of the calibration and measurements. In this study, scattered thermal neutrons were measured and calculated to clarify the characteristics of the thermal neutron scattered from various materials which are frequently used for the jigs. A spherical BF 3 -counter of 2-inches in diameter was used in the experiment. Ratios of the fluence of scattered neutrons to primaries (hereinafter, scattering ratio) were evaluated as a function of thickness and size of the materials, as well as the distance from the surface of the materials. The scattering ratios of the jigs that were actually-used in the calibration were also measured in order to select appropriate materials and thickness for the jigs. It was found that the scattering ratios were saturated with increase of thickness and size of the materials. The higher values were observed in the case of PMMA (polymethylmethacrylates) and paraffin since these materials contain more number of hydrogen atoms than the others. The saturated value was obtained 130% for PMMA and paraffin with the thickness of more than 5 cm and the size of 40 cm x 40 cm. The results for the actually-used jigs show that the thinner plate of styrofoam and aluminum reduces the scattering ratio to the value of less than 1%. The obtained data will be useful to improve the accuracy of the calibration of thermal neutron detectors and the measurement of reference fluence rates in thermal neutron irradiation fields. (author)

  16. Experimental evaluation of scattered thermal neutrons from various jig materials for use in fixing detectors for the calibration

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Shigeru; Yoshizawa, Michio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nemoto, Hisashi; Kurosawa, Koji [Institute of Radiation Measurement, Tokai, Ibaraki (Japan)

    2000-05-01

    Some jigs to fix detectors are used when radiation measuring instruments are calibrated or reference fluence rates are measured in thermal neutron irradiation fields. In this case, scattered thermal neutrons from the jigs, in particular, which contain hydrogenous materials, may affect the results of the calibration and measurements. In this study, scattered thermal neutrons were measured and calculated to clarify the characteristics of the thermal neutron scattered from various materials which are frequently used for the jigs. A spherical BF{sub 3}-counter of 2-inches in diameter was used in the experiment. Ratios of the fluence of scattered neutrons to primaries (hereinafter, scattering ratio) were evaluated as a function of thickness and size of the materials, as well as the distance from the surface of the materials. The scattering ratios of the jigs that were actually-used in the calibration were also measured in order to select appropriate materials and thickness for the jigs. It was found that the scattering ratios were saturated with increase of thickness and size of the materials. The higher values were observed in the case of PMMA (polymethylmethacrylates) and paraffin since these materials contain more number of hydrogen atoms than the others. The saturated value was obtained 130% for PMMA and paraffin with the thickness of more than 5 cm and the size of 40 cm x 40 cm. The results for the actually-used jigs show that the thinner plate of styrofoam and aluminum reduces the scattering ratio to the value of less than 1%. The obtained data will be useful to improve the accuracy of the calibration of thermal neutron detectors and the measurement of reference fluence rates in thermal neutron irradiation fields. (author)

  17. A zero-to-few-hundred eV proton beam for calibrations of neutron beta decay experiments

    CERN Document Server

    Naab, F; Zech, W; García, A; Mumm, P

    2002-01-01

    We have constructed a system using a duoplasmatron source to produce a beam of low-energy (0 - few hundred eV) protons with the principal goal of testing and calibrating detectors used to detect protons from neutron beta decay. The system is stable and produces beams by simply turning on the associated power supplies without the need of careful tuning. As an example we show data from calibration of a surface barrier detector in the emiT apparatus. Protons from the system were scattered from an Al target and used to calibrate detectors in the emiT apparatus.

  18. Determination of Th and U by neutron activation for gamma spectrometry calibration in situ

    International Nuclear Information System (INIS)

    Nava M, F.; Rios M, C.; Mireles G, F.; Saucedo A, S.; Davila R, I.; Pinedo, J. L.; Landsberger, S.

    2012-10-01

    Using the analysis by neutron activation to determine the profile of the thorium and uranium concentration calibration factors were obtained for their use in the gamma spectrometry in situ. Three sites were selected (San Ramon, Villa de Cos y la Zacatecana) and the analysis by activation was development in the Laboratory of Nuclear Engineering Teaching of the Texas University in Austin with the nuclear reactor Ut-TRIGA. Starting from the gamma spectra in situ, the areas of normalized photo-pick of the radioisotopes were: 208 Tl and 228 Ac for the thorium series and 214 Pb and 214 Bi for the uranium series. The averages of the factors found in units of (cpm/Bq/Kg) are of 105.63±8.32 and 75.87±4.61 for the thorium and uranium, respectively. (Author)

  19. Cosmic Ray Neutron Sensing: Use, Calibration and Validation for Soil Moisture Estimation

    International Nuclear Information System (INIS)

    2017-03-01

    Nuclear and related techniques can help develop climate-smart agricultural practices by optimizing water use efficiency. The measurement of soil water content is essential to improve the use of this resource in agriculture. However, most sensors monitor small areas (less than 1m in radius), hence a large number of sensors are needed to obtain soil water content across a large area. This can be both costly and labour intensive and so larger scale measuring devices are needed as an alternative to traditional point-based soil moisture sensing techniques. The cosmic ray neutron sensor (CRNS) is such a device that monitors soil water content in a non-invasive and continuous way. This publication provides background information about this novel technique, and explains in detail the calibration and validation process.

  20. Precision of neutron scattering and capacitance type soil water content gauges from field calibration

    International Nuclear Information System (INIS)

    Evett, S.R.; Steiner, J.L.

    1995-01-01

    Soil water content gauges based on neutron scattering (NS) have been a valuable tool for soil water investigations for some 40 yr. However, licensing, training, and safety regulations pertaining to the radioactive source in these gauges makes their use expensive and prevents use in some situations such as unattended monitoring. A capacitance probe (CP) gauge has characteristics that would seem to make it an ideal replacement for NS gauges. We determined the relative precision of two brands of NS gauges (three gauges of each) and a brand of CP gauge (four gauges) in a field calibration exercise. Both brands of NS gauges were calibrated vs. volumetric soil water content with coefficients of determination (r2) ranging from 0.97 to 0.99 and root mean squared errors (RMSE) 0.012 m3 m-3 water content. Calibrations for the CP gauges resulted in r2 ranging from 0.68 to 0.71 and RMSE of 0.036 m3 m-3 water content. Average 95% confidence intervals on predictions were three to five times higher for the CP gauges than for the NS gauges, ranging from 0.153 to 0.161 and 0.032 to 0.052 m3 m-3, respectively. Although poorly correlated with soil water content, readings were reproducible among the four CP gauges. The poor correlation for CP gauges may be due to small-scale soil water content variations within the measurement volume of the gauge. The NS gauges provide acceptable precision but the CP gauge has poor precision and is unacceptable for routine soil water content measurements

  1. Well swab collar

    Energy Technology Data Exchange (ETDEWEB)

    1969-04-09

    A well swab collar which can be hoisted to bring well fluids upward through a pipe string is described. An elastic swab is used to swab a pipe having a predetermined diameter. The swab consists of a circular shaped elastomer body having an outer diameter a little smaller than the inner diameter of the pipe. The body is divided into multiple swab elements by ring-shaped grooves in the body. The swab element has truncated conical surfaces directed radially at an outward angle, then downward and consequently at an angle inward and then downward. (19 claims)

  2. Development of the neutron reference calibration field using a {sup 252}Cf standard source surrounded with PMMA moderators

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, T.; Kanai, K.; Tsujimura, N. [Japan Nuclear Cycle Development Institute, Ibaraki-ken (Japan)

    2002-07-01

    The authors developed the neutron reference calibration fields using a {sup 252} Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the {sup 252} Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO{sub 2}-UO{sub 2} mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments.

  3. Development of the neutron reference calibration field using a 252Cf standard source surrounded with PMMA moderators

    International Nuclear Information System (INIS)

    Yoshida, T.; Kanai, K.; Tsujimura, N.

    2002-01-01

    The authors developed the neutron reference calibration fields using a 252 Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the 252 Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments

  4. Photon contributions from the 252Cf and 241Am–Be neutron sources at the PSI Calibration Laboratory

    International Nuclear Information System (INIS)

    Hoedlmoser, H.; Boschung, M.; Meier, K.; Stadtmann, H.; Hranitzky, C.; Figel, M.; Mayer, S.

    2012-01-01

    At the accredited PSI Calibration Laboratory neutron reference fields traceable to the national standards of the Physikalisch-Technische Bundesanstalt (PTB) in Germany are available for the calibration of ambient and personal dose equivalent (rate) meters and passive dosimeters. The photon contribution to the ambient dose equivalent in the neutron fields of the 252 Cf and 241 Am–Be sources was measured using various photon dose rate meters and active and passive dosimeters. Measuring photons from a neutron source usually involves considerable uncertainties due to the presence of neutron induced photons in the room, due to a non-zero neutron sensitivity of the photon detector, and last but not least due to the energy response of the photon detectors. Therefore eight independent detectors and methods were used to obtain a reliable estimate for the photon contribution of the two sources as an average of the individual methods. For the 241 Am–Be source a photon contribution of approximately 4.9% was determined and for the 252 Cf source a contribution of 3.6%.

  5. Effect of some soil physical properties on water holding capacity, neutron probe calibration and salt movement

    International Nuclear Information System (INIS)

    Razzouk, A. K.

    2010-04-01

    This study was conducted in tow areas representing in silty soil in Southern Syria (Draa), loamy and sandy soil in Eastern Syria (Deir Al zour) to compare the soil effect on the calibration of the neutron probe, correlation coefficient, soil characteristics curve, soil solution content of nitrates, potassium and sodium for the estimation of the optimum sampling time of soil solution by porous ceramic cups. Regression analysis results showed that the three soils curves, in which the soil contained the lowest content of clay had a high correlation coefficient and decreased with increasing the clay content. Whereas, the correlation coefficient in sandy soil was 0.96 while decreased to 0.79 in silty soil. The hydraulic head increased with decreasing the water content, which was obvious in the three soils characteristic curves. The NO - 3 content decreased due to the plants roots absorption and leaching to deeper layers, while the NO - 3 content in the surfaces layer significantly decreased in the sandy soil. Results showed that equilibrium between the soil solution and the NO - 3 content in the solution in porous cups occurred within 8 days. (author)

  6. Monitoring Landscape Scale Soil Water Content with Cosmic-Ray Neutron Sensors: Validation and Calibration

    International Nuclear Information System (INIS)

    Wahbi, Ammar; Avery, William A.; Dercon, Gerd; Heng, Lee; Weltin, Georg; Franz, Trenton E.; Strauss, Peter; Oismueller, Markus; Desilets, Darin

    2017-01-01

    Increasing populations growth combined with climate change are putting pressure on water resources and agricultural systems around the world. The need for effective water management strategies designed to maximize water use efficiency has made access to soil water content (SWC) information crucial to the global community. This work builds upon ongoing research that began in December 2013 in which a stationary Cosmic-Ray Neutron Sensor (CRNS) was used to monitor SWC within an agricultural system located in north central Austria. Past work at this study site at Petzenkirchen, Austria (100 km west of Vienna) has focused on the calibration and validation of the CRNS technology, and has shown the CRNS to reliably estimate SWC on a large scale (circle with radius of cca. 250 m) when compared to other methods of estimating SWC. This was determined via comparisons of insitu soil sampling, time domain reflectometry (TDR), and time domain transmissivity (TDT) of SWC with estimates of SWC determined from the CRNS. However, questions remain regarding the effective use of the CRNS technology.

  7. Effect of some soil physical properties on water holding capacity, neutron probe calibration and salt movement

    International Nuclear Information System (INIS)

    Razzouk, A.

    2010-01-01

    This study was conducted in tow areas representing in silty soil in Southern Syria (Dra'a), loamy and sandy soil in Eastern Syria (Deir Al zour) to compare the soil effect on the calibration of the neutron probe, correlation coefficient, soil characteristics curve, soil solution content of nitrates, potassium and sodium for the estimation of the optimum sampling time of soil solution by porous ceramic cups. Regression analysis results showed that the three soils curves, in which the soil contained the lowest content of clay had a high correlation coefficient and decreased with increasing the clay content. Whereas, the correlation coefficient in sandy soil was 0.96 while decreased to 0.79 in silty soil. The hydraulic head increased with decreasing the water content, which was obvious in the three soils characteristic curves. The NO 3 content decreased due to the plants roots absorption and leaching to deeper layers, while the NO 3 content in the surfaces layer significantly decreased in the sandy soil. Results showed that equilibrium between the soil solution and the NO 3 content in the solution in porous cups occurred within 8 days. (author)

  8. Optimization of shadow cone length and mass for determination the amount of scattered radiation dose in the calibration laboratory of Am/Be neutron source

    International Nuclear Information System (INIS)

    Raisali, G.; Hamidi, S.; Hallajfard, E.; Shahvar, A.; Hajiloo, N.

    2007-01-01

    The shadow cone technique is one of the methods which is used for determining the contribution of scattered particles on the response of neutron detectors. This technique is used for neutron field calibration in Agriculture, Medicine and Industry Research School. In this investigation, we have designed and constructed an optimized shadow cone. According to the calculated neutron dose equivalent attenuation factors, a cone with 20 cm of iron and 30 cm of polyethylene has been found as optimum. For this cone, the neutron dose equivalent attenuation factor for 241 Am/Be neutron source, is 0.00035 for which the contribution of scattered neutrons in Agriculture, Medicine and Industry Research School neutron calibration laboratory according to the calculation and measurement results, can be evaluated with less than 0.5% of error

  9. 30 CFR 77.1010 - Collaring holes.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Collaring holes. 77.1010 Section 77.1010... Control § 77.1010 Collaring holes. (a) Starter steels shall be used when collaring holes with hand-held drills. (b) Men shall not hold the drill steel while collaring holes, or rest their hands on the chuck or...

  10. Augmented collar for assistance dog

    OpenAIRE

    Lemasson , Germain; Lucidarme , Philippe; Pesty , Sylvie; Duhaut , Dominique

    2014-01-01

    In this paper we present briefly our reflexion on how to communicate with a dog using embedded devices. We also present the prototype collar we made in order to improve the communication between an assistance dog and his disabled master.

  11. An Improved Nuclear Recoil Calibration in the LUX Detector Using a Pulsed D-D Neutron Generator

    Science.gov (United States)

    Huang, Dongqing

    2017-01-01

    The LUX dark matter search experiment is a 370 kg (250 kg active mass) two-_phase liquid/gas xenon time projection chamber located at the 4850 ft level of the Sanford Underground Research Facility in Lead, SD. The first absolute charge (Qy) and light (Ly) measurement performed in situ in the LUX detector with a D-D calibration technique for nuclear recoil spanning 0.7 to 74 keV and 1.1 to 74 keV respectively have been reported in. The D-D calibration has subsequently been further improved by incorporating pulsing technique, i.e. the D-D neutron production is concentrated within narrow pulses (20 us / 250 Hz) with the timing information recorded. This technique allows the suppression of accidental backgrounds in D-D neutron data and also provides increased sensitivity for the lower energy NR calibrations. I will report the improved NR absolute Qy and Ly measurements using the pulsed D-D calibration technique performed in situ in the LUX detector. Brown University, Large Underground Xenon(LUX) Collaboration.

  12. Calibration of a neutron polarimeter in the 0.2-1.1GeV region

    International Nuclear Information System (INIS)

    Semenov, A.Yu.; Zhang, W.M.; Madey, R.; Ahmidouch, A.; Anderson, B.D.; Assamagan, K.; Avery, S.; Baldwin, A.R.; Crowell, A.S.; Eden, T.; Manley, D.M.; Markowitz, P.; Milleret, G.; Prout, D.; Reichelt, T.; Semenova, I.A.; Ulmer, P.E.; Voutier, E.; Watson, J.W.; Wells, S.P.

    2006-01-01

    We measured the analyzing power and the efficiency of a neutron polarimeter at the Saturne National Laboratory in France with central energies of the neutron beam of 261,533,752,922, and 1057MeV. This polarimeter was a prototype designed to measure G E n , the neutron electric form factor, at the Thomas Jefferson National Accelerator Facility

  13. The measurement of thermal neutron constants of the soil; application to the calibration of neutron moisture gauges and to the pedological study of soil

    International Nuclear Information System (INIS)

    Couchat, P.; Marcesse, J.; Carre, C.; Le Ho, J.

    1975-01-01

    The neutronic method for measuring the water content of soils is more and more used by agronomists, hydrogeologists and pedologists. On the other hand the studies on the phenomena of slowing down and diffusion process have shown a narrow relation between the thermal absorption (Σ(a)) and diffusion (Σ(d)) constants and the thermal flux developed in the soil around a fast neutron source like Am-Be. Two original applications of the direct measurement of Σ(a) and Σ(d) are then presented. The method described consists in the measurement, in a cube of graphite with Am-Be source in the middle, on one side of the perturbation of the thermal flux, obtained by the introduction of 300g of soil, and on the other side of the transmitted thermal flux measured through the same sample of soil, on a side of the cube. After calibrating the device, these two parameters give Σ(a) and Σ(d) which are easily introduced in the calibration equation of neutron moisture gauge. Also these two values are useful for the pedologists because Σ(d) is connected to clay content in the soil and Σ(a) is connected to the type of clay by the way of rare earth contents [fr

  14. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, C. J., E-mail: cjwaugh@mit.edu; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D. [Plasma Science and Fusion Center, MIT, Cambridge, Massachusetts 02139 (United States); Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C. [Laboratory for Laser Energetics, Rochester, New York 14623 (United States)

    2015-05-15

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  15. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors.

    Science.gov (United States)

    Waugh, C J; Rosenberg, M J; Zylstra, A B; Frenje, J A; Séguin, F H; Petrasso, R D; Glebov, V Yu; Sangster, T C; Stoeckl, C

    2015-05-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  16. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    International Nuclear Information System (INIS)

    Waugh, C. J.; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D.; Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C.

    2015-01-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule

  17. Set-up and calibration of a method to measure {sup 10}B concentration in biological samples by neutron autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Gadan, M.A. [National Commission for Atomic Energy (CNEA), Buenos Aires (Argentina); Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Bortolussi, S., E-mail: silva.bortolussi@pv.infn.it [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); National Institute for Nuclear Physics (INFN), Section of Pavia, Pavia (Italy); Postuma, I. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Ballarini, F. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); National Institute for Nuclear Physics (INFN), Section of Pavia, Pavia (Italy); Bruschi, P. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Protti, N.; Santoro, D.; Stella, S. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); National Institute for Nuclear Physics (INFN), Section of Pavia, Pavia (Italy); Cansolino, L.; Clerici, A.; Ferrari, C.; Zonta, A.; Zonta, C. [Department of Experimental Surgery, University of Pavia, Pavia (Italy); Altieri, S. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); National Institute for Nuclear Physics (INFN), Section of Pavia, Pavia (Italy)

    2012-03-01

    A selective uptake of boron in the tumor is the base of Boron Neutron Capture Therapy, which can destroy the tumor substantially sparing the normal tissue. In order to deliver a lethal dose to the tumor, keeping the dose absorbed by normal tissues below the tolerance level, it is mandatory to know the {sup 10}B concentration present in each kind of tissue at the moment of irradiation. This work presents the calibration procedure adopted for a boron concentration measurement method based on neutron autoradiography, where biological samples are deposited on sensitive films and irradiated in the thermal column of the TRIGA reactor (University of Pavia). The latent tracks produced in the film by the charged particles coming from the neutron capture in {sup 10}B are made visible by a proper etching, allowing the measurement of the track density. A calibration procedure with standard samples provides curves of track density as a function of boron concentration, to be used in the measurement of biological samples. In this paper, the bulk etch rate parameter and the calibration curves obtained for both liquid samples and biological tissues with known boron concentration are presented. A bulk etch rate value of (1.64 {+-} 0.02) {mu}m/h and a linear dependence with etching time were found. The plots representing the track density versus the boron concentration in a range between 5 and 50 {mu}g/g (ppm) are linear, with an angular coefficient of (1.614 {+-} 0.169){center_dot}10{sup -3} tracks/({mu}m{sup 2} ppm) for liquids and (1.598 {+-} 0.097){center_dot}10{sup -2} tracks/({mu}m{sup 2} ppm) for tissues.

  18. Calibration of scintillation-light filters for neutron time-of-flight spectrometers at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sayre, D. B., E-mail: sayre4@llnl.gov; Barbosa, F.; Caggiano, J. A.; Eckart, M. J.; Grim, G. P.; Hartouni, E. P.; Hatarik, R. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); DiPuccio, V. N.; Weber, F. A. [National Security Technologies, Livermore, California 94551 (United States)

    2016-11-15

    Sixty-four neutral density filters constructed of metal plates with 88 apertures of varying diameter have been radiographed with a soft x-ray source and CCD camera at National Security Technologies, Livermore. An analysis of the radiographs fits the radial dependence of the apertures’ image intensities to sigmoid functions, which can describe the rapidly decreasing intensity towards the apertures’ edges. The fitted image intensities determine the relative attenuation value of each filter. Absolute attenuation values of several imaged filters, measured in situ during calibration experiments, normalize the relative quantities which are now used in analyses of neutron spectrometer data at the National Ignition Facility.

  19. Neutron spectrometry and dosimetry measurement at workplaces for calibration of individual PGP-DIN dosemeters

    International Nuclear Information System (INIS)

    Itie, C.; Muller, H.; Asselineau, B.; Medioni, R.; Crovisier, P.; Valier-Bradier, P.; Groetz, J.E.; Piot, J.

    2003-01-01

    Measurements to determine new coefficients for individual neutron dosimeters PGP-DIN complying with the ICRP 60 recommendations were performed at two workplaces at the CEA of Valduc: a storage room and a plutonium reprocessing plant. Two spectrometry campaigns were performed allowing a better assessment of doses received by operators working at these workplaces. Neutron energy fluence and ambient dose equivalent rate H * (10) distributions were measured as function of neutron energy by using the ROSPEC device and BONNER spheres spectrometer. The radiation field being mixed neutron and gamma, the gamma component was also evaluated: neutron and photon dose-rate meters were used to evaluate the ambient dose rate equivalent. Individual dosemeters were positioned on an ISO water slab phantom. In addition, calculations were performed using the MCNP simulation code for different configurations. (authors)

  20. A calibration method for realistic neutron dosimetry in radiobiological experiments assisted by MCNP simulation.

    Science.gov (United States)

    Shahmohammadi Beni, Mehrdad; Krstic, Dragana; Nikezic, Dragoslav; Yu, Kwan Ngok

    2016-09-01

    Many studies on biological effects of neutrons involve dose responses of neutrons, which rely on accurately determined absorbed doses in the irradiated cells or living organisms. Absorbed doses are difficult to measure, and are commonly surrogated with doses measured using separate detectors. The present work describes the determination of doses absorbed in the cell layer underneath a medium column (D A ) and the doses absorbed in an ionization chamber (D E ) from neutrons through computer simulations using the MCNP-5 code, and the subsequent determination of the conversion coefficients R (= D A /D E ). It was found that R in general decreased with increase in the medium thickness, which was due to elastic and inelastic scattering. For 2-MeV neutrons, conspicuous bulges in R values were observed at medium thicknesses of about 500, 1500, 2500 and 4000 μm, and these were attributed to carbon, oxygen and nitrogen nuclei, and were reflections of spikes in neutron interaction cross sections with these nuclei. For 0.1-MeV neutrons, no conspicuous bulges in R were observed (except one at ~2000 μm that was due to photon interactions), which was explained by the absence of prominent spikes in the interaction cross-sections with these nuclei for neutron energies <0.1 MeV. The ratio R could be increased by ~50% for small medium thickness if the incident neutron energy was reduced from 2 MeV to 0.1 MeV. As such, the absorbed doses in cells (D A ) would vary with the incident neutron energies, even when the absorbed doses shown on the detector were the same. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  1. Advisory Committee for the calibration standards of ionizing radiation measurement. Section 3. Neutron measurements

    International Nuclear Information System (INIS)

    1980-01-01

    Section III (Neutron measurements) of the Comite Consultatif pour les Etalons de Mesure des Rayonnements ionisants held its fourth meeting in April 1979. After discussing the final report on the fast neutron fluence rate intercomparison, it requested BIPM to submit it for publication in Metrologia. Section III studied the state-of-the-art of an international comparison of a 252 Cf (10 7 s -1 ) source which is in progress. A new fast neutron fluence rate intercomparison is scheduled for 1980; the energies and the methods to be used have been investigated. Finally, Section III studied carefully and rewrote a proposal for a 14-MeV neutron dosimetry facility at BIPM, and added a Recommendation for CCEMRI [fr

  2. Advisory Committee for the Calibration Standards of Ionizing Radiation Measurement: Section 3. Neutron measurements

    International Nuclear Information System (INIS)

    1982-01-01

    Section III (Mesures neutroniques) of the Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants held its fifth meeting in May 1981. Recent work carried out at BIPM in the field of neutron measurements was reported. The status of a full-scale 252 Cf neutron source intercomparison (10 7 s - 1 ) and of several restricted comparisons was discussed. Intercomparisons of fast neutron fluence rates are in progress ( 115 In(n,n') 115 Insup(m); NB/Zr) or will take place in the near future ( 115 n(n,#betta#) 116 Insup(m); 235 U and 238 U fission chambers). An intercomparison of neutron dosimetry standards by circulating tissue-equivalent ion chambers will be prepared and organized by BIPM. Finally, there was a broad exchange of information on work in progress at the various laboratories represented at the meeting [fr

  3. Neutron scattering facility for the calibration of the response to nuclear recoils

    International Nuclear Information System (INIS)

    Jochum, J.; Feilitzsch, F. von; Huber, M.; Jagemann, T.; Lachenmaier, T.; Lanfranchi, J.-C.; Potzel, W.; Ruedig, A.; Schnagl, J.; Stark, M.; Wulandari, H.; Chambon, B.; Drain, D.; Gascon, J.; Jesus, M. de; Martineau, O.; Simon, E.; Stern, M.

    2002-01-01

    A possibility to search for elementary particles as dark matter candidates is to detect elastic scattering with cryogenic detectors. For the interpretation of the data one has to determine the detector response to nuclear recoils, the so-called quenching factors. They can differ for the heat-, for the scintillation- and for the ionization-signal and can be measured by scattering of neutrons. The CRESST- and the EDELWEISS-collaborations have set up a neutron scattering facility for cryogenic detectors at the tandem-accelerator of the Munich 'Maier-Leibniz-Labor.' The scattering angle and the time-of-flight of the neutrons are measured by an array of liquid scintillator cells. The pulsed high energy (11 MeV) neutron beam is created by nuclear reaction of a 11 B on a H 2 -gas target. The set-up and the results of first tests are presented

  4. Optimized calibration of neutronic-thermodynamic simulator for low power fast reactors

    International Nuclear Information System (INIS)

    Jachic, J.; Waintraub, M.

    1986-01-01

    Aiming to a general optimization of the project, controlled fuel depletion and management and yet motivated the feasibility of application of the SIRZ simulator to solve such problem, we present here an optimized and systematic calibration of this simulator. Are shown explicitly the control variables and the corresponding calibration equations for the buckling factors. After iterative linearizations, the resultant Linear Programming Problems were solved by the SIMPLEX Method. The results show that the optimum calibration is easily obtained if convergence control parameters are adequately chosen. (Author) [pt

  5. Calibration facilities at Hanford for gamma-ray and fission-neutron well logging

    International Nuclear Information System (INIS)

    Stromswold, D.C.

    1994-07-01

    Well-logging tools that detect gamma rays emitted from earth formations need to be calibrated in appropriate facilities to provide quantitative assessments of concentrations o radionuclides based on detected gamma rays. These facilities are typically special models having a hole to insert tools and having sufficient physical size to simulate actual earth formations containing known amounts of radionuclides. The size, generally 3 to 5 feet in diameter and 4 to 6 feet tall, is such that the source of radiation appears infinite in extent to a tool detecting the radiation inside the model. Such models exist at Hanford as concrete cylinders having a central borehole and containing known, enhanced amounts of K, U, and Th. Data collected in these models allow calibration of the logging system to measure radionuclide concentrations in formations around boreholes in the field. The accuracy of the calculated field concentrations depends on the correctness of the original calibration, the statistical precision of the data, and the similarity of the logging conditions to the calibration conditions. Possible methods for analyzing the data collected in the calibration facilities are presented for both spectral and total-count gamma-ray systems. Corrections are typically needed for the effects of steel casing in boreholes and the presence of water rather than air in the holes. Data collected in the calibration models with various steel casings and borehole fluids allow such correction factors to be determined

  6. Collar of Lady's Wear in Qing Dynasty

    Institute of Scientific and Technical Information of China (English)

    LI Xiao-jun

    2007-01-01

    The research is started with a query that whether the width of collar in Qing Dynasty Is too small. The paper bases on the statistics which come from the collection of the Costume Museum of Donghua University. compares the results with the natlonal standard specification, then analyzes the structure and shape of collars in Qing Dynasty, and tells the relationship between collar and the garment. Furthermore, the paper discusses the function of lady's collar in Qing Dynasty and gives a suggestion that collar being an Indicator to distinguish women's wear from children's wear.

  7. Why Blue-Collar Blacks Help Less

    OpenAIRE

    Smith, Sandra Susan; Young, Kara Alexis

    2013-01-01

    Why are blue-collar blacks less likely to help jobseekers than jobholders from other ethnoracial groups or even than more affluent blacks? Drawing from in-depth, semi-structured interviews with 97 black and Latino workers at one large, public sector employer, we find that blue-collar black workers both helped less proactively and rejected more requests for assistance than did blue-collar Latino and white-collar black workers. We attribute blue-collar blacks’ more passive engagement to their...

  8. 37Ar based neutron source for calibration of the iodine solar neutrino detector

    International Nuclear Information System (INIS)

    Abdurashitov, D.N.; Gavrin, V.N.; Mirmov, I.N.; Veretenkin, E.P.; Yants, V.Eh.; Cleveland, B.T.; Davis, R. Jr.; Lande, K.; Wildenhain, P.; Khomyakov, Yu.S.

    2001-01-01

    The methodology of the creation of a compact neutrino source based on the 37 Ar isotope as well as the technique of calibration of an iodine detector of solar neutrinos is described. An important overall expected result is the creation of a prototype of the source with the intensity up to 400 kCi, delivery of this source to the Baksan neutrino observatory and the test calibration of the single module of the iodine detector. Simulation shows that at least 45-70 127 Xe atoms will be detected in the irradiation of ∼40 tons of methylene iodide by the source leading to ∼19% of the error on the measured production rate. This result should be considered as a test of the developed technology and will verify overall technical readiness for the creation of a full scale neutrino source and the full scale calibration of the iodine detector

  9. Feasibility of calibration of liquid sodium flowmeters by neutron activation techniques

    International Nuclear Information System (INIS)

    Kehler, P.

    1976-07-01

    Velocities of fluids in pipes can be measured by injecting radioactive tracers into the fluid and recording the activity downstream of the injection point. One convenient method of injecting radioactive tracers is by neutron activation of the fluid itself. The present report describes a FORTRAN program that can be used for the prediction of the counting rates of fluid flow tests performed with a pulsed neutron source and a scintillation detector. The program models the flow profile and the mixing of the fluid, the attenuation of neutrons and gamma rays in the fluid, and the geometric arrangement of the source and the detector. Using this program, an experiment for the measurement of the secondary sodium flow of the EBR-II was optimized. A pulsed D,T neutron source and a 5 in. x 5 in. NaI detector will be used in the EBR-II test. Under optimized conditions, the expected accuracy of the flow measurement is about 2 percent

  10. Monte carlo efficiency calibration of a neutron generator-based total-body irradiator

    Science.gov (United States)

    The increasing prevalence of obesity world-wide has focused attention on the need for accurate body composition assessments, especially of large subjects. However, many body composition measurement systems are calibrated against a single-sized phantom, often based on the standard Reference Man mode...

  11. A comparison of different neutron probes calibration method for the soil surface and their radiation effect on the users

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, A; Razzouk, A K; Al-Ain, F [Atomic Energy commission , Damascus (Syrian Arab Republic). Dept of Radiation Agriculture

    1996-08-01

    In situ calibration curves were installed for the soil surface using different models of depth neutron probes and different adaptors. depth beutron probe readings increased with increasing the number of teflon plastic blocks deposited on the soil surface. The intercept of the straight line regression analysis decreased with increasing of teflon plastics blocks deposited on the soil surface in all sites. The least exposure was with depth probe with surface reflectors. This study proves the possibility of measuring the moisture content of the soil surface by using a depth probe with a block laid on the surface, without a danger of receiving the thresgold of radiation dose. (author). 10 Refs., 2 Figs., 8 Tabs.

  12. Health and pink-collar work.

    Science.gov (United States)

    Basu, S; Ratcliffe, G; Green, M

    2015-10-01

    In recent years, there has been a decline in the manufacturing sector of the UK economy with a corresponding growth of service-orientated pink-collar jobs in some regions. While the health outcomes of white- and blue-collar workers are well-established, less is known about this emerging pink-collar group. To outline the health of pink-collar workers in comparison to their white-collar counterparts across a range of indicators. Area-level percentages for white-, pink- and blue-collar workers were derived from residents' routinely collected employment data in a northern English town. Area-level health data pertaining to male and female life expectancy, respiratory deaths and deaths from cardiovascular and circulatory causes (all age and under 75 years) were obtained from the local authority and public health observatory. Multivariate regression analyses were performed to assess relationships between job collar and health. When adjusted for deprivation, areas with higher percentages of pink-collar workers experienced lower rates of death from circulatory disease under the age of 75 in comparison to white-collar workers. Other relationships between collar status and health outcomes were not statistically significant. The reasons underlying the apparent protective effect of pink-collar status for deaths from circulatory disease are uncertain and merit further study. Possibilities include differences in age, exposure to occupational hazards and lifestyle behaviours. Our work has a number of limitations and longitudinal studies with detailed exposure data should assess the long-term health outcomes of these workers using agreed definitions. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. A Collar for Marking Big Game Animals

    Science.gov (United States)

    Robert L. Phillips

    1970-01-01

    A Simple, inexpensive collar made of Armor-tite (a vinyl-coated nylon fabric) was designed for marking white-tailed deer (Odocoileus virginianus) and moose (Alces alces). Field tests showed that the material is easily seen and extrememly durable. It may be suitable for use on other large mammals. The collar can be quickly fitted to individual animals under field...

  14. Characterization of the neutron field of the {sup 241}AmBe in a calibration room; Caracterizacion del campo de neutrones del {sup 241} AmBe en una sala para calibracion

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Universidad Politecnica de Madrid, C. Jose Gutierrez Abascal 2, 28006 Madrid (Spain)] e-mail: rvega@cantera.reduaz.mx

    2003-07-01

    The field of neutrons produced by an isotopic source of neutrons of {sup 241} Am Be had been characterized. The characterization was carried out modeling those relevant details of the calibration room and simulating the neutron transport at different distances of the source. The calculated spectra were used to determine the equivalent environmental dose rate. A series of experiments were carried out with the Bonner sphere spectrometric system to measure the spectra in the same points where the calculations were carried out and with these spectra the rates of environmental dose were calculated. By means of a one sphere dosemeter type Berthold the rates of environmental dose were measured. To the one to compare the calculated spectra and measured its were found small differences in the group of the thermal neutrons due to the elementary composition used during the simulation. When comparing the derived rates starting from the calculated spectra with those measured it was found a maxim difference smaller to 13%. (Author)

  15. Calibration Tools for Measurement of Highly Enriched Uranium in Oxide and Mixed Uranium-Plutonium Oxide with a Passive-Active Neutron Drum Shuffler

    International Nuclear Information System (INIS)

    Mount, M; O'Connell, W; Cochran, C; Rinard, P

    2003-01-01

    Lawrence Livermore National Laboratory (LLNL) has completed an extensive effort to calibrate the LLNL passive-active neutron drum (PAN) shuffler (Canberra Model JCC-92) for accountability measurement of highly enriched uranium (HEU) oxide and HEU in mixed uranium-plutonium (U-Pu) oxide. Earlier papers described the PAN shuffler calibration over a range of item properties by standards measurements and an extensive series of detailed simulation calculations. With a single normalization factor, the simulations agree with the HEU oxide standards measurements to within ±1.2% at one standard deviation. Measurement errors on mixed U-Pu oxide samples are in the ±2% to ±10% range, or ±20 g for the smaller items. The purpose of this paper is to facilitate transfer of the LLNL procedure and calibration algorithms to external users who possess an identical, or equivalent, PAN shuffler. Steps include (1) measurement of HEU standards or working reference materials (WRMs); (2) MCNP simulation calculations for the standards or WRMs and a range of possible masses in the same containers; (3) a normalization of the calibration algorithms using the standard or WRM measurements to account for differences in the 252 Cf source strength, the delayed-neutron nuclear data, effects of the irradiation protocol, and detector efficiency; and (4) a verification of the simulation series trends against like LLNL results. Tools include EXCEL/Visual Basic programs which pre- and post-process the simulations, control the normalization, and embody the calibration algorithms

  16. The final power calibration of the IPEN/MB-01 nuclear reactor for various configurations obtained from the measurements of the absolute average neutron flux

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alexandre Fonseca Povoa da, E-mail: alexandre.povoa@mar.mil.br [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil); Bitelli, Ulysses d' Utra; Mura, Luiz Ernesto Credidio; Lima, Ana Cecilia de Souza; Betti, Flavio; Santos, Diogo Feliciano dos, E-mail: ubitelli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The use of neutron activation foils is a widely spread technique applied to obtain nuclear parameters then comparing the results with those calculated using specific methodologies and available nuclear data. By irradiation of activation foils and subsequent measurement of its induced activity, it is possible to determine the neutron flux at the position of irradiation. The power level during operation of the reactor is a parameter which is directly proportional to the average neutron flux throughout the core. The objective of this work is to gather data from irradiation of gold foils symmetrically placed along a cylindrically configured core which presents only a small excess reactivity in order to derive the power generated throughout the spatial thermal and epithermal neutron flux distribution over the core of the IPEN/MB-01 Nuclear Reactor, eventually lending to a proper calibration of its nuclear channels. The foils are fixed in a Lucite plate then irradiated with and without cadmium sheaths so as to obtain the absolute thermal and epithermal neutron flux. The correlation between the average power neutron flux resulting from the gold foils irradiation, and the average power digitally indicated by the nuclear channel number 6, allows for the calibration of the nuclear channels of the reactor. The reactor power level obtained by thermal neutron flux mapping was (74.65 ± 2.45) watts to a mean counting per seconds of 37881 cps to nuclear channel number 10 a pulse detector, and 0.719.10{sup -5} ampere to nuclear linear channel number 6 (a non-compensated ionization chamber). (author)

  17. Development, improvement and calibration of neutronic reaction rate measurements: elaboration of a base of standard techniques; Developpement, amelioration et calibration des mesures de taux de reaction neutroniques: elaboration d`une base de techniques standards

    Energy Technology Data Exchange (ETDEWEB)

    Hudelot, J.P

    1998-06-19

    In order to improve and to validate the neutronic calculation schemes, perfecting integral measurements of neutronic parameters is necessary. This thesis focuses on the conception, the improvement and the development of neutronic reaction rates measurements, and aims at building a base of standard techniques. Two subjects are discussed. The first one deals with direct measurements by fission chambers. A short presentation of the different usual techniques is given. Then, those last ones are applied through the example of doubling time measurements on the EOLE facility during the MISTRAL 1 experimental programme. Two calibration devices of fission chambers are developed: a thermal column located in the central part of the MINERVE facility, and a calibration cell using a pulsed high flux neutron generator and based on the discrimination of the energy of the neutrons with a time-of-flight method. This second device will soon allow to measure the mass of fission chambers with a precision of about 1 %. Finally, the necessity of those calibrations will be shown through spectral indices measurements in core MISTRAL 1 (UO{sub 2}) and MISTRAL 2 (MOX) of the EOLE facility. In each case, the associated calculation schemes, performed using the Monte Carlo MCNP code with the ENDF-BV library, will be validated. Concerning the second one, the goal is to develop a method for measuring the modified conversion ratio of {sup 238}U (defined as the ratio of {sup 238}U capture rate to total fission rate) by gamma-ray spectrometry of fuel rods. Within the framework of the MISTRAL 1 and MISTRAL 2 programmes, the measurement device, the experimental results and the spectrometer calibration are described. Furthermore, the MCNP calculations of neutron self-shielding and gamma self-absorption are validated. It is finally shown that measurement uncertainties are better than 1 %. The extension of this technique to future modified conversion ratio measurements for {sup 242}Pu (on MOX rods) and

  18. Use of cervical collar after whiplash injuries.

    Science.gov (United States)

    Józefiak-Wójtowicz, Anna; Stolarczyk, Artur; Deszczyński, Jarosław Michał; Materek, Magdalena; Pietras, Marta; Bażant, Katarzyna

    2014-08-08

    Whiplash injuries, also known as neck sprains and strains, are currently some of the most common injuries of the cervical spine. Mechanism of injury is still controversial and current treatment methods do not provide satisfactory results. In this article we present QTF classification of related disorders, epidemiological data and treatment methods. We described basic principles of using a soft collar, goals and effects of collar use and potential complications ensuing from immobilization. Authors reviewed publications comparing the effects of collar use with other methods of treatment and physiotherapy following whiplash injury.

  19. Expert System for 3D Collar Intelligent Design

    Institute of Scientific and Technical Information of China (English)

    LIU Yan; GENG Zhao-feng

    2004-01-01

    A method to set up 3D collar prototype is developed in this paper by using the technique of cubic spline and bicubic surface patch. Then the relationship between the parameters of 3D collar prototype and different collar styles are studied. Based on the relationship, we can develop some algorithms of transferring style requirements to the parameters value of the collar prototype, and obtain some generation rules for the design of 3D collar style. As such, the knowledge base can be constructed, and the intelligent design system of 3D collar style is built. Using the system, various 3D collar styles can be designed automatically to satisfy various style requirements.

  20. [Factors associated with depressive symptoms in blue-collar and white-collar male workers].

    Science.gov (United States)

    Kawasaki, Yurika; Nishitani, Naoko; Sakakibara, Hisataka

    2015-01-01

    Mental disorders are increasing and their influence on productivity is a concern in the workplace. However, few studies have investigated depression among blue-collar and white-collar workers in the manufacturing industry. The purpose of this study was to clarify the factors associated with depressive symptoms, focusing on lifestyles and insomnia. A self-administered questionnaire survey was conducted of 1,963 workers at an annual health checkup in a manufacturing company. Of the 1,712 respondents (response rate: 87%), 1,258 male worker subjects (blue-collar 674; white-collar 584) were analyzed after excluding those with mental diseases. The questionnaire included items on basic attributes and lifestyle. The Athens Insomnia Scale (AIS) and The Center for Epidemiologic Studies for Depression Scale (CES-D) were used to evaluate insomnia and depressive symptoms. The incidence of depressive symptoms with CES-D scores of ≥16 was 15.1% in both the blue-collar and the white-collar workers. Insomnia with AIS scores of ≥6 were encountered in 18.8% of the blue-collar workers and 18.3% of the white-collar workers. Multiple logistic regression analyses showed that for the blue-collar workers, depressive symptoms were associated with "AIS scores ≥6" (Odds ratio (OR): 10.93; 95% confidence interval (CI): 6.12-19.15), "not get rid of fatigue with sleep" (OR: 3.36; 95%CI: 1.85-6.09), "skip breakfast over 3 times a week" (OR: 3.10; 95%CI:1.42-6.76), "no family living together" (OR: 2.08; 95%CI: 1.05-4.12), and "commuting time" (OR: 1.01; 95%CI: 1.00-1.02). For the white-collar workers, depressive symptoms were related to "AIS scores ≥6" (OR: 14.91; 95%CI: 7.54-29.49), and "no family living together" (OR: 2.54; 95%CI: 1.27-5.09). Sleep time was not associated with depression in both blue- and white-collar workers. Depressive symptoms were found in 51.6% of the blue-collar workers with insomnia with AIS scores ≥6 and 53.8% of white-collar workers. Depressive symptoms were

  1. Calibration of the Lawrence Livermore National Laboratory Passive-Active Neutron Drum Shuffler for Measurement of Highly Enriched Uranium in Mixed Oxide

    International Nuclear Information System (INIS)

    Mount, M.; O'Connell, W.; Cochran, C.; Rinard, P.; Dearborn, D.; Endres, E.

    2002-01-01

    As a follow-on to the Lawrence Livermore National Laboratory (LLNL) effort to calibrate the LLNL passive-active neutron drum (PAN) shuffler for measurement of highly enriched uranium (HEU) oxide, a method has been developed to extend the use of the PAN shuffler to the measurement of HEU in mixed uranium-plutonium (U-Pu) oxide. This method uses the current LLNL HEU oxide calibration algorithms, appropriately corrected for the mixed U-Pu oxide assay time, and recently developed PuO 2 calibration algorithms to yield the mass of 235 U present via differences between the expected count rate for the PuO 2 and the measured count rate of the mixed U-Pu oxide. This paper describes the LLNL effort to use PAN shuffler measurements of units of certified reference material (CRM) 149 (uranium (93% Enriched) Oxide - U 3 O 8 Standard for Neutron Counting Measurements) and CRM 146 (uranium Isotopic Standard for Gamma Spectrometry Measurements) and a selected set of LLNL PuO 2 -bearing containers in consort with Monte Carlo simulations of the PAN shuffler response to each to (1) establish and validate a correction to the HEU calibration algorithm for the mixed U-Pu oxide assay time, (2) develop a PuO 2 calibration algorithm that includes the effect of PuO 2 density (2.4 g/cm 3 to 4.8 g/cm 3 ) and container size (8.57 cm to 9.88 cm inside diameter and 9.60 cm to 13.29 cm inside height) on the PAN shuffler response, and (3) develop and validate the method for establishing the mass of 235 U present in an unknown of mixed U-Pu oxide.

  2. Detecting neutrons by forward recoil protons at the Energy & Transmutation facility: Detector development and calibration with 14.1-MeV neutrons

    Science.gov (United States)

    Afanasev, S.; Vishnevskiy, A.; Vishnevskiy, D.; Rogachev, A.; Tyutyunnikov, S.

    2017-05-01

    As part of the Energy & Transmutation project, we are developing a detector for neutrons with energies in the 10-100 MeV range emitted from the target irradiated by a charged-particle beam. The neutron is detected by measuring the time-of-flight and total kinetic energy of the forward-going recoil proton [1] knocked out at a small angle from a thin layer of plastic scintillator, which has to be selected against an intense background created by γ quanta, scattered neutrons, and charged particles. On the other hand, neutron energy has to be measured over the full range with no extra tuning of the detector operation regime. Initial measurements with a source of 14.1-MeV neutrons are reported.

  3. SYSTEMATIC UNCERTAINTIES IN THE SPECTROSCOPIC MEASUREMENTS OF NEUTRON STAR MASSES AND RADII FROM THERMONUCLEAR X-RAY BURSTS. III. ABSOLUTE FLUX CALIBRATION

    Energy Technology Data Exchange (ETDEWEB)

    Güver, Tolga [Istanbul University, Science Faculty, Department of Astronomy and Space Sciences, Beyazıt, 34119, Istanbul (Turkey); Özel, Feryal; Psaltis, Dimitrios [Department of Astronomy, University of Arizona, 933 N. Cherry Avenue, Tucson, AZ 85721 (United States); Marshall, Herman [Center for Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Guainazzi, Matteo [European Space Astronomy Centre of ESA, P.O. Box 78, Villanueva de la Cañada, E-28691 Madrid (Spain); Díaz-Trigo, Maria [ESO, Karl-Schwarzschild-Strasse 2, D-85748 Garching bei München (Germany)

    2016-09-20

    Many techniques for measuring neutron star radii rely on absolute flux measurements in the X-rays. As a result, one of the fundamental uncertainties in these spectroscopic measurements arises from the absolute flux calibrations of the detectors being used. Using the stable X-ray burster, GS 1826–238, and its simultaneous observations by Chandra HETG/ACIS-S and RXTE /PCA as well as by XMM-Newton EPIC-pn and RXTE /PCA, we quantify the degree of uncertainty in the flux calibration by assessing the differences between the measured fluxes during bursts. We find that the RXTE /PCA and the Chandra gratings measurements agree with each other within their formal uncertainties, increasing our confidence in these flux measurements. In contrast, XMM-Newton EPIC-pn measures 14.0 ± 0.3% less flux than the RXTE /PCA. This is consistent with the previously reported discrepancy with the flux measurements of EPIC-pn, compared with EPIC MOS1, MOS2, and ACIS-S detectors. We also show that any intrinsic time-dependent systematic uncertainty that may exist in the calibration of the satellites has already been implicity taken into account in the neutron star radius measurements.

  4. Trunnion Collar Removal Machine - Gap Analysis Table

    International Nuclear Information System (INIS)

    Johnson, M.

    2005-01-01

    The purpose of this document is to review the existing the trunnion collar removal machine against the ''Nuclear Safety Design Bases for License Application'' (NSDB) [Ref. 10] requirements and to identify codes and standards and supplemental requirements to meet these requirements. If these codes and standards can not fully meet these requirements then a ''gap'' is identified. These gaps will be identified here and addressed using the ''Trunnion Collar Removal Machine Design Development Plan'' [Ref. 15]. The codes and standards, supplemental requirements, and design development requirements for the trunnion collar removal machine are provided in the gap analysis table (Appendix A, Table 1). Because the trunnion collar removal machine is credited with performing functions important to safety (ITS) in the NSDB [Ref. 10], design basis requirements are applicable to ensure equipment is available and performs required safety functions when needed. The gap analysis table is used to identify design objectives and provide a means to satisfy safety requirements. To ensure that the trunnion collar removal machine performs required safety functions and meets performance criteria, this portion of the gap analysis tables supplies codes and standards sections and the supplemental requirements and identifies design development requirements, if needed

  5. Update on Calibration of the Lawrence Livermore National Laboratory Passive-Active Neutron Drum Shuffler for Measurement of Highly Enriched Uranium Oxide

    International Nuclear Information System (INIS)

    Mount, M.; O'Connell, W.; Cochran, C.; Rinard, P.; Dearborn, D.; Endres, E.

    2002-01-01

    In October of 1999, Lawrence Livermore National Laboratory (LLNL) began an effort to calibrate the LLNL passive-active neutron (PAN) drum shuffler for measurement of highly enriched uranium (HEU) oxide. A single unit of certified reference material (CRM) 149 (Uranium (93% Enriched) Oxide - U 3 O 8 Standard for Neutron Counting Measurements) was used to (1) develop a mass calibration curve for HEU oxide in the nominal range of 393 g to 3144 g 235 U, and (2) perform a detailed axial and radial mapping of the detector response over a wide region of the PAN shuffler counting chamber. Results from these efforts were reported at the Institute of Nuclear Materials Management 4lSt Annual Meeting in July 2000. This paper describes subsequent efforts by LLNL to use a unit of CRM 146 (Uranium Isotopic Standard for Gamma Spectrometry Measurements) in consort with Monte Carlo simulations of the PAN shuffler response to CRM 149 and CRM 146 units and a selected set of containers with CRM 149-equivalent U 3 O 8 to (1) extend the low range of the reported mass calibration curve to 10 g 235 U, (2) evaluate the effect of U 3 O 8 density (2.4 g/cm 3 to 4.8 g/cm 3 ) and container size (5.24 cm to 12.17 cm inside diameter and 6.35 cm to 17.72 cm inside height) on the PAN shuffler response, and (3) develop mass calibration curves for U 3 O 8 enriched to 20.1 wt% 235 U and 52.5 wt% 235 U.

  6. Calibration of the nuclear power channels for the cylindrical configuration of the IPEN/MB-01 reactor obtained from the measurements of the spatial neutron flux distribution in the reactor core through the irradiation of gold foils

    Energy Technology Data Exchange (ETDEWEB)

    Bitelli, Ulysses d' Utra; Silva, Alexandre F. Povoa da; Mura, Luiz Ernesto Credidio; Aredes, Vitor Ottoni Garcia; Santos, Diogo Feliciano dos, E-mail: ubitelli@ipen.br, E-mail: alexpovoa@yahoo.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The activation foil is one of the most used techniques to obtain and compare nuclear parameters from the nuclear data libraries, given by a gamma spectrometry system. Through the measurements of activity induced in the foils, it is possible to determine the neutron flux profile exactly where it has been irradiated. The power level operation of the reactor is a parameter directly proportional to the average neutron flux in the core. The objective of this work is to obtain, for a cylindrical configuration, the power generation through a spatial thermal neutron flux distribution in the core of IPEN/MB-01 Reactor, by irradiating gold foils positioned symmetrically into the core. They are put in a Lucite plate which will not interfere in the analysis of the neutron flux, because of its low microscopic absorption cross section for the analyzed neutrons. The foils are irradiated with and without cadmium covered small plates, to obtain the thermal and epithermal neutron flux, through specific equations. The correlation between the average power neutron flux, as a result of the foil's irradiation, and the average power digital neutron flux of the nuclear power channels, allows the calibration of the nuclear channels of the reactor. This same correlation was done in 2008 with the reactor in a rectangular configuration, which resulted in a specific calibration of the power level operation. This calibration cannot be used in the cylindrical configuration, because the nuclear parameters could change, which may lead to a different neutron profile. Furthermore, the precise knowledge of the power neutron flux in the core also validates the mathematics used to calculate the power neutron flux. (author)

  7. Characterisation of the IRSN CANEL/T400 facility producing realistic neutron fields for calibration and test purposes

    International Nuclear Information System (INIS)

    Gressier, V.; Lacoste, V.; Lebreton, L.; Muller, H.; Pelcot, G.; Bakali, M.; Fernandez, F.; Tomas, M.; Roberts, N. J.; Thomas, D. J.; Reginatto, M.; Wiegel, B.; Wittstock, J.

    2004-01-01

    The new CANEL/T400 facility has been set-up at the Inst. for Radiological Protection and Nuclear Safety (IRSN) to produce a realistic neutron field. The accurate characterisation of this neutron field is mandatory since this facility will be used as a reference neutron source. For this reason an international measuring campaign, involving four laboratories with extensive expertise in neutron metrology and spectrometry, was organised through a concerted EUROMET project. Measurements were performed with Bonner sphere (BS) systems to determine the energy distribution of the emitted neutrons over the whole energy range (from thermal energy up to a few MeV). Additional measurements were performed with proton recoil detectors to provide detailed information in the energy region above 90 keV. The results obtained by the four laboratories are in agreement with each other and are compared with a calculation performed with the MCNP4C Monte-Carlo code. As a conclusion of this exercise, a reliable characterisation of the CANEL/T400 neutron field is obtained. (authors)

  8. Criminal Trajectories of White-collar Offenders

    NARCIS (Netherlands)

    van Onna, J.; van der Geest, V.R.; Huisman, W.; Denkers, A.J.M.

    2014-01-01

    Objectives:This article analyzes the criminal development and sociodemographic and criminal profile of a sample of prosecuted white-collar offenders. It identifies trajectory groups and describes their profiles based on crime, sociodemographic, and selection offence characteristics.Methods:The

  9. Wolves, Canis lupus, carry and cache the collars of radio-collared White-tailed Deer, Odocoileus virginianus, they killed

    Science.gov (United States)

    Nelson, Michael E.; Mech, L. David

    2011-01-01

    Wolves (Canis lupus) in northeastern Minnesota cached six radio-collars (four in winter, two in spring-summer) of 202 radio-collared White-tailed Deer (Odocoileus virginianus) they killed or consumed from 1975 to 2010. A Wolf bedded on top of one collar cached in snow. We found one collar each at a Wolf den and Wolf rendezvous site, 2.5 km and 0.5 km respectively, from each deer's previous locations.

  10. Reducing Local Scouring at Bridge Piles Using Collars and Geobags

    Directory of Open Access Journals (Sweden)

    Shatirah Akib

    2014-01-01

    Full Text Available The present study examines the use of collars and geobags for reducing local scour around bridge piles. The efficiency of collars and geobags was studied experimentally. The data from the experiments were compared with data from earlier studies on the use of single piles with a collar and with a geobag. The results showed that using a combination of a steel collar and a geobag yields the most significant scour reduction for the front and rear piles, respectively. Moreover, the independent steel collar showed better efficiency than the independent geobag below the sediment level around the bridge piles.

  11. Biomedical and biophysical research and calibration projects: radiobiology. Chromosomal aberrations in human lymphocytes - response to mixed neutron/photon exposures

    International Nuclear Information System (INIS)

    Slabbert, J.P.; Hough, J.H.; Jansen, S.

    1991-01-01

    Whether synergistic interaction damage is realized when lymphocytes are exposed to mixed high/low LET radiation fields, and if so, how well these effects can be predicted, was investigated. Whole-blood samples were exposed, at 37 degrees C, to neutrons, 60 Co gamma-rays and a mixture of 25% neutrons and 75% photons. The mixture was delivered both sequentially and simultaneously. A significant difference between the sequential and simultaneous irradiations was evident. Both mixed-field exposures yield aberration frequencies in excess of the sum predicted for individual irradiations. 5 refs., 2 figs., 1 tab

  12. Field and laboratory calibration of neutron probes for soil moisture measurements on a deep loess chernozem soil

    International Nuclear Information System (INIS)

    Schaecke, B.; Schaecke, E.

    1979-01-01

    In the case of a varying profile structure it is necessary to use different calibration curves and adequate correction factors, respectively. The bulk density of the soil had the greatest influence on the calibration. An increase in bulk density by 0.2 g/cm 3 at a clay content of 18% resulted in an apparent increase in the values of moisture measurements by 1.5 to 2.0% of the volume of water. In naturally stratified soil the humus content of the chernozem horizon, being 3% higher than that of the underlying loess horizon, was found to influence the measuring results obtained by the probe. The calibration curves determined for chernozem and loess horizons in the laboratory agreed well with those obtained in the field. The measured values read from the probe and the gravimetrically determined values of the soil moisture were of great significance in all measured depths of the profile. (author)

  13. Generalized collar waves in acoustic logging while drilling

    International Nuclear Information System (INIS)

    Wang Xiu-Ming; He Xiao; Zhang Xiu-Mei

    2016-01-01

    Tool waves, also named collar waves, propagating along the drill collars in acoustic logging while drilling (ALWD), strongly interfere with the needed P- and S-waves of a penetrated formation, which is a key issue in picking up formation P- and S-wave velocities. Previous studies on physical insulation for the collar waves designed on the collar between the source and the receiver sections did not bring to a satisfactory solution. In this paper, we investigate the propagation features of collar waves in different models. It is confirmed that there exists an indirect collar wave in the synthetic full waves due to the coupling between the drill collar and the borehole, even there is a perfect isolator between the source and the receiver. The direct collar waves propagating all along the tool and the indirect ones produced by echoes from the borehole wall are summarized as the generalized collar waves. Further analyses show that the indirect collar waves could be relatively strong in the full wave data. This is why the collar waves cannot be eliminated with satisfactory effect in many cases by designing the physical isolators carved on the tool. (special topic)

  14. White-Collar Crimes and Financial Corruptions

    Directory of Open Access Journals (Sweden)

    Fatih ŞENTÜRK

    2013-12-01

    Full Text Available Crime, defined as act which is contrary to the law, creates negative influence in the society both economically and spiritually. There are various factors like professional experience as well as biological, psychological and sociological ones that make individuals turn to crime. Edwin Sutherland claim that life experiences and some facts learned from the environment account for occupational crimes in his study on the theory of crime in 1939. White-collar crime, which is perhaps the most important of types of crime in terms of havoc and committed by the superior contrary to common belief, has much more influence than conventional crime. This crime, which inflict significant financial loses and psychological collapse on states, communities, businesses and people, are committed by well-respected professionals in their business. In this study, white collar crimes are examined with conceptual view and detailed. Besides, this study explain this type of crime is so forceful, by giving remarkable examples on economic losses.

  15. LHC collars - 12 million high technology gems

    CERN Multimedia

    2001-01-01

    Some 12 million steel collars will keep the LHC dipole magnet structures rigid. Their production has just begun. A huge job began last week: the high speed manufacturing of twelve million steel collars for the 1250 dipole magnets of the future Large Hadron Collider, LHC. The challenge is not only a matter of quantity: these collars are very high technology components because of the important role they play in the way the collider works. One of the main difficulties with the accelerator is that the magnetic field that keeps particles in orbit must have the same configuration and intensity in all the dipoles. But when the 8.33 tesla magnetic field is on -100.000 times the earth magnetic field - it produces a very strong force that can deform the 'soft' parts of the magnets, such as superconducting coils. The force loading one metre of dipole is almost comparable with the weight of a Boeing 747 - about 400 tonnes - so a huge deformation would occur without a mechanical component to keep the whole structure rigid...

  16. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  17. Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?

    Science.gov (United States)

    Bonin, Nicolas; Gedouin, Jean-Emmanuel; Pibarot, Vincent; Bejui-Hughues, Jacques; Bothorel, Hugo; Saffarini, Mo; Batailler, Cécile

    2017-10-03

    Even if the benefits of collars are unclear, they remain widely used, in several femoral stem designs. This study aimed to determine whether collar size should be proportional to hip dimensions and morphology. The hypothesis was that the collar should be larger for greater stem sizes and for varus femoral necks. Computed Tomography scans of 204 healthy hips were digitally analysed and manually templated to determine principle dimensions, appropriate stem size and model, as well as cortical distance at the femoral calcar (ideal collar size). Univariable analysis revealed that cortical distance was moderately correlated with mediolateral offset (r = 0.572; p < 0.0001) and stem model (r = 0.520; p < 0.0001). Cortical distance was weakly correlated with head diameter (r = 0.399; p < 0.0001), stem size (r = 0.200; p = 0.017), and patient gender (r = 0.361; p < 0.0001). Multivariable analysis confirmed that stem model (p < 0.0001) and head diameter (p = 0.0162) are directly correlated to cortical distance. We found that cortical distance along the femoral calcar is directly correlated with the model of the stem implanted ('standard' or 'varus') and with the head diameter. This cortical distance indicates optimal collar size, which would grant maximum calcar coverage without prosthetic overhang. Collar size should be proportional to the size of the operated hip, and should be larger for 'varus' stem models than for 'standard' stem models.

  18. Characterization of thermal neutron fields for calibration of neutron monitors in accordance with great equivalent dose environment H⁎(10); Caracterização de campos de nêutrons térmicos para a calibração de monitores de nêutrons em termos da grandeza equivalente de dose ambiente H⁎(10)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Larissa P. S. da; Silva, Felipe S.; Fonseca, Evaldo S.; Patrao, Karla C.S.; Pereira, Walsan W. [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Laboratório Nacional de Metrologia das Radiações Ionizantes; Astuto, Achilles, E-mail: larissapaizante@poli.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Laboratório Brasileiro de Nêutrons do Instituto de Radioproteção e Dosimetria (IRD/CNEN) has developed and built a thermal neutron flux facility to provide neutron fluence for dosimeters (Astuto, 2014). This fluency is obtained by four 16 Ci sources {sup 241}AmBe (α, n) positioned around the channel positioned in the center of the Thermal Flow Unit (UFT). The UFT was built with blocks of paraffin with graphite addition and graphite blocks of high purity to obtain a central field with a homogeneous thermal neutron fluence for calibration purposes with the following measurements: 1.2 x 1.2 x 1.2 m{sup 3}. The objective of this work is to characterize several points, in the thermal energy range, in terms of the equivalent ambient dose quantity H⁎(10) for calibration and irradiation of monitors neutrons.

  19. Mechanical test results on Dipole model C-1 25 mm aluminum collars

    International Nuclear Information System (INIS)

    Peters, C.

    1985-02-01

    This report is a summary of procedures used in collaring the SSC Dipole model C-1. Included are descriptions of the collars, instrumentation, collar pack preparation, collaring procedures, and collar dimension and coil pressure data measurements taken during and testing of the magnet

  20. Testing and linearity calibration of films of phenol compounds exposed to thermal neutron field for EPR dosimetry.

    Science.gov (United States)

    Gallo, S; Panzeca, S; Longo, A; Altieri, S; Bentivoglio, A; Dondi, D; Marconi, R P; Protti, N; Zeffiro, A; Marrale, M

    2015-12-01

    This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was found and the signal was compared with that of commercial alanine films. Our analysis showed that gadolinium oxide (5% by weight) can enhance the thermal neutron sensitivity more than 18 times. Irradiated dosimetric films of phenolic compound exhibited EPR signal fading of about 4% after 10 days from irradiation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Minimum dimensions of rock models for calibration of radiometric probes for the neutron-gamma well logging

    International Nuclear Information System (INIS)

    Czubek, J.A.; Lenda, A.

    1979-01-01

    The minimum dimensions have been calculated assuring 91, 96 and 98 % of the probe response in respect to the infinite medium. The models are of cylindrical form, the probe (source-to-detector distance equal to 60 or 90 cm) being placed on the model axis, symmetrically with respect to the two end-faces. All the models are ''embedded'' in various media, such as: air, sand of 40% porosity and completely saturated with water, sand of 30 % porosity and of moisture content equal to 10 %, and water. The models are of three types of material: sandstone, limestone and dolomite, with various porosities, ranging from 0 to 100 %. The probe response is due to gamma rays arising from the radiativecapture of thermal neutrons. The calculations were carried out for the highest energy line of gamma rays arising in given litology. Gamma-ray flux from the neutron radiative capture has been calculated versus rock porosity and model dimensions and radiation migration lengths determined for given litologies. The minimum dimensions of cylindrical models are given as functions of: porosity, probe length (source-to-detector distance) lithology of model and type of medium surrounding our model. (author)

  2. Individual neutron dosimetry

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  3. Atmospheric neutrons

    International Nuclear Information System (INIS)

    Preszler, A.M.; Moon, S.; White, R.S.

    1976-01-01

    Additional calibrations of the University of California double-scatter neutron and additional analysis corrections lead to the slightly changed neutron fluxes reported here. The theoretical angular distributions of Merker (1975) are in general agreement with our experimental fluxes but do not give the peaks for vertical upward and downward moving neutrons. The theoretical neutron escape current J 2 /sub pi/ (Merker, 1972; Armstrong et al., 1973) is in agreement with the experimental values from 10 to 100 MeV. Our experimental fluxes agree with those of the Kanbach et al. (1974) in the overlap region from 70 to 100 MeV

  4. Neutron dosimetry; Dosimetria de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Fratin, Luciano

    1993-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is

  5. Neutron dosimetry; Dosimetria de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Fratin, Luciano

    1994-12-31

    A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosemeters. A 185 GBq {sup 241} Am Be source of known is used as a reference source. The irradiation facility using this source in the air provides neutron dose rates between 9 nSv s{sup -1} and 0,5 {sup {mu}}Sv s{sup -1}. A calibrated 50 nSv s{sup -1} thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the {sup 241} Am Be source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfold {sup 241} Am Be neutron spectrum was determined from the Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosemeter badge using a (n,{alpha}) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59 deg C, 20 kV{sub pp} cm{sup -1}, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosemeter. The sensitivities determined for the developed dosimetric system were (1,46{+-} 0,09) 10{sup 4} tracks cm{sup -2} mSv{sup -1} for thermal neutrons, (9{+-}3) 10{sup 2} tracks cm{sup -2} mSV{sup -1} for intermediate neutrons and (26{+-}4) tracks cm{sup -2} mSv{sup -1} for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990`s ICRP recommendations, it is possible to conclude that the personal dosemeter described in this work is

  6. A self-adjusting expandable GPS collar for male elk

    Science.gov (United States)

    Brian L. Dick; Scott L. Findholt; Bruce K. Johnson

    2013-01-01

    It is a challenge to use collars on male cervids because their neck size can increase substantially during the rut and also because of growth as the animal matures. We describe how to build a self-adjusting expandable collar for yearling or adult male Rocky Mountain elk (Cervus elaphus) to which very high frequency transmitters and global...

  7. Draining Collars and Lenses in Liquid-Lined Vertical Tubes.

    Science.gov (United States)

    Jensen

    2000-01-01

    The speed at which an annular liquid collar drains under gravity g in a vertical tube of radius a, when the tube has an otherwise thin viscous liquid lining on its interior, is determined by a balance between the collar's weight and viscous shear stresses confined to narrow regions in the neighborhood of the collar's effective contact lines. Whether a collar grows or shrinks in volume as it drains depends on the modified Bond number B=rho g a(2)/(sigmaepsilon), where rho is the fluid density, sigma is its surface tension, and epsilona is the thickness of the thin film immediately ahead of the collar. Asymptotic methods are used here to determine the following nonlinear stability criteria for an individual collar, valid in the limit of small epsilon. For 0draining collars grow in volume and, in sufficiently long tubes, ultimately "snap off" to form stable lenses. For 0.5960drain, so that any lens ultimately ruptures, unless stabilizing intermolecular forces allow the formation of a lamella supported by a macroscopic Plateau border. If surfactant immobilizes the liquid's free surface, these critical values of B are reduced by a factor of 2 but the distance a collar must travel before it snaps off is unchanged. Gravitationally driven snap off is therefore most likely to occur in long tubes with radii substantially less than the capillary lengthscale sigma/rhog)(1/2). Copyright 2000 Academic Press.

  8. Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?

    Directory of Open Access Journals (Sweden)

    B. Alper Gultekin

    2016-01-01

    Full Text Available Purpose. To compare marginal bone loss between subgingivally placed short-collar implants with machined collars and those with machined and laser-microtextured collars. Materials and Methods. The investigators used a retrospective study design and included patients who needed missing posterior teeth replaced with implants. Short-collar implants with identical geometries were divided into two groups: an M group, machined collar; and an L group, machined and laser-microtextured collar. Implants were evaluated according to marginal bone loss, implant success, and probing depth (PD at 3 years of follow-up. Results. Sixty-two patients received 103 implants (56 in the M group and 47 in the L group. The cumulative survival rate was 100%. All implants showed clinically acceptable marginal bone loss, although bone resorption was lower in the L group (0.49 mm than in the M group (1.38 mm at 3 years (p<0.01. A significantly shallower PD was found for the implants in the L group during follow-up (p<0.01. Conclusions. Our results suggest predictable outcomes with regard to bone loss for both groups; however, bone resorption was less in the L group than in the M group before and after loading. The laser-microtextured collar implant may provide a shallower PD than the machined collar implant.

  9. Calibration of the nuclear power channels of the IPEN/MB-01 reactor obtained from the measurements of the spatial thermal neutron flux distribution in the reactor core through the irradiation of infinitely diluted gold foils

    International Nuclear Information System (INIS)

    Goncalves, Lucas Batista

    2008-01-01

    Several nuclear parameters are obtained through the gamma spectrometry of targets irradiated in a research reactor core and this is the case of the activation foils which make possible, through the measurements of the activity induced, to determine the neutron flux in the place where they had been irradiated. The power level operation of the reactor is a parameter directly proportional to the average neutron flux in the core. This work aims to get the power operation of the reactor through of spatial neutron flux distribution in the core of IPEN/MB-01 reactor by the irradiation of infinitely diluted gold foils and prudently located in its interior. These foils were made in the form of metallic alloy in concentration levels such that the phenomena of flux disturbance, as the self-shielding factors to neutrons become worthless. These activation foils has only 1% of dispersed gold atoms in an aluminium matrix content of 99% of this element. The irradiations of foils have been carried through with and without cadmium plate. The total correlation between the average thermal neutron flux obtained by irradiation of infinitely diluted activation foils and the average digital value of current of the nuclear power channels 5 and 6 (non-compensated ionization chambers - CINC), allow the calibration of the nuclear channels of the IPEN/MB-01 reactor. (author)

  10. 1:100k Digital Raster Graphic - Collars Removed

    Data.gov (United States)

    Minnesota Department of Natural Resources — A digital raster graphic (DRG) is a scanned image of an U.S. Geological Survey (USGS) standard series topographic map, including all map collar information. The...

  11. Occupational contact dermatitis in blue-collar workers

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Menné, Torkil; Veien, Niels K

    2014-01-01

    BACKGROUND: Blue-collar workers have a high risk of occupational contact dermatitis, but epidemiological studies are scarce. OBJECTIVES: To investigate allergic contact dermatitis in blue-collar workers with dermatitis registered by the Danish Contact Dermatitis Group. METHODS: A retrospective...... analysis of patch test data from 1471 blue-collar workers and 1471 matched controls tested between 2003 and 2012 was performed. A logistic regression was used to test for associations. RESULTS: The blue-collar workers often had occupational hand dermatitis (p dermatitis was less commonly......, and methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI). The following occupations were additionally identified as risk factors for contact sensitization to MCI/MI and MI, epoxy resins, and potassium dichromate, respectively: painting, construction work, and tile setting/terrazzo work. CONCLUSION: Contact allergy...

  12. Calibration of SPND/Rhodium device for mapping the neutron fluence in the IEA-R1 reactor by means of the activation foil method; Calibracao de um dispositivo de mapeamento de fluxo de neutrons - SNPD/Rodio no reator IEA-R1, por meio do metodo de ativacao de folhas

    Energy Technology Data Exchange (ETDEWEB)

    Ricci Filho, Walter; Dias, Mauro S.; Tondin, Julio B.M.; Koskinas, Marina F. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2002-07-01

    The IEA-R1 reactor has undergone a modernization to increase its operating power to 5 MW, in order to allow a more efficient production of radioisotopes. The objective of this work is to provide the reactor with flux monitoring device using a rhodium Self-Powered Neutron Detector (SPND). The work presents the results obtained with Rhodium-SPND in several irradiation positions inside the reactor core. A calibration procedure has been performed by means of {sup 197} Au activation foils, with and without cadmium cover, in order do measure the thermal and epithermal neutron fluxes. (author)

  13. [Health impact assessment of "white-collar exemption" in Japan].

    Science.gov (United States)

    Fujino, Yoshihisa; Matsuda, Shinya

    2007-03-01

    This work conducted a health impact assessment (HIA) of the Japanese Government's proposal concerning the introduction of so called "white-collar exemption" into the Japanese labor market. We adopted the Merseyside model and performed a rapid health impact assessment to assess the potential health effects of white-collar exemption. In this HIA, several health determinants which may possibly be affected, both positively and negatively, were identified based on experts' judgments. Literature evidence was assessed using PubMed and other databases. In addition, we searched for the opinions of those affected by white-collar exemption from internet web sites, and six concerns were identified. Long working hours were identified as the most serious concern by both experts and those affected. White-collar exemption may increase irregular working patterns which may be related to sleep disorder, stress, and cardiovascular disease. Family function and social participation will also be affected by irregular working patterns. On the other hand, in terms of stress, white-collar exemption may benefit from a higher degree of job control. There are possibilities that white-collar exemption may enable an improved work-life balance and enable access of some groups of the population, such as people with disabilities or parents looking after children, greater access to the labour market. However, it is uncertain whether the benefits of white-collar exemption would overcome those of the current free-time or flex-time systems. The present work provides a wide range of health impacts of white-collar exemption, and will hopefully attract the attentions of decision-makers and those likely to be affected in order to contribute to policy-making.

  14. Comparison between {sup 241}AmBe (α, n) sources in the calibration of survey monitors for neutrons in magnitude H⁎(10); Comparação entre fontes de {sup 241}AmBe (α,n) na calibração de monitores de área para nêutrons na grandeza H⁎(10)

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, W.W.; Filho, C.A.L.S.; Silva, F.S.; Patrão, K.C.S., E-mail: walsanwagner@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Estrada, J.J.S. [Fundação Técnico Educacional Souza Marques, Rio de Janeiro, RJ (Brazil); Alves, C.F.E.; Magalhães, L.A.G.; Leite, S.P. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2017-07-01

    Recently the Laboratório de Ciências Radiológicas (LCR / UERJ) characterized a {sup 241}AmBe (α, n) neutron source for metrological use. This source comes from the Oil Company and it was originally used in well logging tools. In this work, this source was used in the calibration of an survey meter using procedures and facilities of the Laboratório Nacional de Metrologia das Radiações Ionizantes (LN/LNMRI). The results of the calibration with the LCR neutron source agreed with those obtained when the LN/LNMRI neutron source was used. (author)

  15. Testing VHF/GPS collar design and safety in the study of free-roaming horses.

    Directory of Open Access Journals (Sweden)

    Gail H Collins

    Full Text Available Effective and safe monitoring techniques are needed by U.S. land managers to understand free-roaming horse behavior and habitat use and to aid in making informed management decisions. Global positioning system (GPS and very high frequency (VHF radio collars can be used to provide high spatial and temporal resolution information for detecting free-roaming horse movement. GPS and VHF collars are a common tool used in wildlife management, but have rarely been used for free-roaming horse research and monitoring in the United States. The purpose of this study was to evaluate the design, safety, and detachment device on GPS/VHF collars used to collect free-roaming horse location and movement data. Between 2009 and 2010, 28 domestic and feral horses were marked with commercial and custom designed VHF/GPS collars. Individual horses were evaluated for damage caused by the collar placement, and following initial observations, collar design was modified to reduce the potential for injury. After collar modifications, which included the addition of collar length adjustments to both sides of the collar allowing for better alignment of collar and neck shapes, adding foam padding to the custom collars to replicate the commercial collar foam padding, and repositioning the detachment device to reduce wear along the jowl, we observed little to no evidence of collar wear on horses. Neither custom-built nor commercial collars caused injury to study horses, however, most of the custom-built collars failed to collect data. During the evaluation of collar detachment devices, we had an 89% success rate of collar devices detaching correctly. This study showed that free-roaming horses can be safely marked with GPS and/or VHF collars with minimal risk of injury, and that these collars can be a useful tool for monitoring horses without creating a risk to horse health and wellness.

  16. Simulated workplace neutron fields

    International Nuclear Information System (INIS)

    Lacoste, V.; Taylor, G.; Rottger, S.

    2011-01-01

    The use of simulated workplace neutron fields, which aim at replicating radiation fields at practical workplaces, is an alternative solution for the calibration of neutron dosemeters. They offer more appropriate calibration coefficients when the mean fluence-to-dose equivalent conversion coefficients of the simulated and practical fields are comparable. Intensive Monte Carlo modelling work has become quite indispensable for the design and/or the characterization of the produced mixed neutron/photon fields, and the use of Bonner sphere systems and proton recoil spectrometers is also mandatory for a reliable experimental determination of the neutron fluence energy distribution over the whole energy range. The establishment of a calibration capability with a simulated workplace neutron field is not an easy task; to date only few facilities are available as standard calibration fields. (authors)

  17. Thermal neutron calibration of a tritium extraction facility using the 6Li(n,t)4He/197Au(n,γ)198Au cross section ratio for standardization

    International Nuclear Information System (INIS)

    Bretscher, M.M.; Smith, D.L.

    1980-08-01

    Absolute tritium activities in a neutron-activated metallic lithium samples have been measured by liquid scintillation methods to provide data needed for the determination of capture-to-fission ratios in fast breeder reactor spectra and for recent measurements of the 7 Li(n,n't) 4 He cross section. The tritium extraction facility used for all these experiments has now been calibrated by measuring the 6 Li(n,t) 4 He/ 197 Au/n,γ) 198 Au activity ratio for thermal neutrons and comparing the result with the well-known cross sections. The calculated-to-measured activity ratio was found to be 1.033 +- 0.018. 2 figures, 20 tables

  18. Reactor neutron dosimetry

    International Nuclear Information System (INIS)

    Najzer, M.; Pauko, M.; Glumac, B.; Acquah, I.N.; Moskon, F.

    1977-01-01

    An analysis of requirements and possibilities for experimental neutron spectrum determination during the reactor pressure vessel surveil lance programme is given. Fast neutron spectrum and neutron dose rate were measured in the Fast neutron irradiation facility of our TRIGA reactor. It was shown that the facility can be used for calibration of neutron dosimeters and for irradiation of samples sensitive to neutron radiation. The investigation of the unfolding algorithm ITER was continued. Based on this investigations are two specialized unfolding program packages ITERAD and ITERGS written this year. They are able to unfold data from activation detectors and NaI(T1) gamma spectrometer respectively

  19. New pulsating casing collar to improve cementing quality

    Energy Technology Data Exchange (ETDEWEB)

    Chen, P. [Southwest Petroleum Inst., Nanchong, Sichuan (China); He, K. [JiangHan Petroleum Administration Bureau, Qianjiang, Hubei (China); Wu, J. [Chevron Petroleum Tech. Co., Houston, TX (United States)

    1998-12-31

    This paper presents the design and test results of a new pulsating casing collar which improves cementing quality. The new pulsating casing collar (PCC) is designed according to the Helmholtz oscillator to generate a pulsating jet flow by self-excitation in the cementing process. By placing this new pulsating casing collar at the bottom of casing string, the generated pulsating jet flow transmits vibrating pressure waves up through the annulus and helps remove drilling mud in the annulus. It can therefore improve cementing quality, especially when eccentric annulus exists due to casing eccentricity where the mud is difficult to remove. The new pulsating casing collar consists of a top nozzle, a resonant chamber, and a bottom nozzle. It can be manufactured easily and is easy to use in the field. It has been tested in Jianghan oil-field, P.R. China. The field-test results support the theoretical analysis and laboratory test, and the cementing quality is shown greatly improved by using the new pulsating casing collar.

  20. Tribological characterization of the drill collars and casing friction couples

    Science.gov (United States)

    Ripeanu, R. G.; Badicioiu, M.; Caltaru, M.; Dinita, A.; Laudacescu, E.

    2018-01-01

    Drill collars are special pipes used in the drilling of wells for weighting the drill bit, enabling it to drill through the rock. In the drilling process, the drill collars are exposed to an intensive wear due to friction on inner surface of casing wall. In order to evaluate the tribological behaviour of this friction couple, paper presents the drill collars parent material, reconditioned and casing pipe chemical composition, microstructures, hardness and friction tests. For friction tests were prepared samples extracted from new and reconditioned drill collars and from casing pipes and tested on a universal tribometer. Were used plane-on-disk surface friction couples and tests were conducted at two sliding speeds and three normal loads for each materials couple. Plane static partner samples were extracted from casing pipes and disks samples were extracted from new and reconditioned drill collars. Were obtained friction coefficients values and also the temperatures increasing values due to friction working tests parameters. The temperature increasing values were obtained by measuring it with an infrared thermographic camera.

  1. PFN tool test and calibration system

    International Nuclear Information System (INIS)

    Stephenson, W.A.

    1981-12-01

    A system has been developed for the functional testing and neutron output calibration of the PFN (Prompt Fission Neutron) Uranium Logging Tool. The system was designed primarily for field work and consists of a special vehicle as well as test apparatus. Only the pertinent instrumentation is described. This document will serve as an Instruction and Test Equipment service manual for those involved with calibration of the neutron output of the PFN tool

  2. Sickness benefit cuts mainly affect blue-collar workers.

    Science.gov (United States)

    Aaviksoo, E; Kiivet, R-A

    2014-08-01

    To analyse the impact of sick-pay cuts on the use of sickness absence by employees of different socioeconomic groups. In 2009 cuts in sick pay were implemented in reaction to an economic crisis in Estonia. Nationwide health survey data from the years 2004, 2006, 2008, and 2010 were used to evaluate sickness absence among blue-collar and white-collar workers. The dataset comprised 7,449 employees of 20-64 years of age. Difference in prevalence of absentees before and after the reform was assessed using the chi-squared test. Odds ratios (OR) for sickness absence were calculated in a multivariate logistic regression model. After the reform, the proportion of blue-collar workers who had been on sick leave decreased from 51% to 40% (pgender, age, self-rated health, and presence of chronic disease, especially among those with low incomes; in white-collar employees it reached statistical significance only in those with good self-rated health (p=0.033). In a multivariate model the odds of having lower sickness absence were highly significant only in blue-collar employees (OR 0.63; 95% confidence interval 0.51-0.77, p<0.001). The cuts in sickness benefits had a major impact on the use of sickness absence by blue-collar employees with low salaries. This indicates that lower income was a major factor hindering the use of sick leave as these employees are most vulnerable to the loss of income. © 2014 the Nordic Societies of Public Health.

  3. White-collar crime: corporate and securities and commodities fraud.

    Science.gov (United States)

    Price, Marilyn; Norris, Donna M

    2009-01-01

    In this era of increased interest in white-collar crime, forensic psychiatrists are in a key position to study the individual characteristics of offenders. While a comprehensive theory of high-level white-collar crime should consider societal and organizational contributions, there is value in understanding the personal traits that place an individual at high risk for offending. As the impact of the criminal acts of this group has been increasingly felt by larger groups from all socioeconomic strata, there is less willingness by the public to view these crimes as victimless and harmless.

  4. Sedentary Behavior of White Collar Office Workers-Review

    OpenAIRE

    Hopkin, T. J.; Sarkar, Swarjit

    2016-01-01

    Aim The aim of this systematic review is to evaluate the physical activity time (PAT) of white collar office workers in order to assess the levels of sedentary activity in an office environment. Analysing the office workers PAT will not only allow an insight into how an office based job could impact a person’s overall health and wellness status, but will also allow for the development of future office based inter ventions aimed at increasing the overall physical activity among white collar of...

  5. Personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  6. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  7. The tokamak as a neutron source

    International Nuclear Information System (INIS)

    Hendel, H.W.; Jassby, D.L.

    1989-11-01

    This paper describes the tokamak in its role as a neutron source, with emphasis on experimental results for D-D neutron production. The sections summarize tokamak operation, sources of fusion and non-fusion neutrons, principal neutron detection methods and their calibration, neutron energy spectra and fluxes outside the tokamak plasma chamber, history of neutron production in tokamaks, neutron emission and fusion power gain from JET and TFTR (the largest present-day tokamaks), and D-T neutron production from burnup of D-D tritons. This paper also discusses the prospects for future tokamak neutron production and potential applications of tokamak neutron sources. 100 refs., 16 figs., 4 tabs

  8. Work Identity and Marital Adjustment in Blue-Collar Men.

    Science.gov (United States)

    Gaesser, David L.; Whitbourne, Susan Krauss

    1985-01-01

    Investigated the relationship between work-identity and satisfaction and marital adjustment in 40 married male blue-collar workers, ages 25 to 41 years. Satisfaction with extrinsic work factors related to marital adjustment, while satisfaction with intrinsic work factors negatively related to secondary role salience. Age negatively related to…

  9. The Origin of Black Smock and White Collar

    Science.gov (United States)

    Hesapcioglu, Muhsin; Meseci Giorgetti, Filiz

    2009-01-01

    Although there are many empirical studies on the functions of school uniform, studies which focus on the origins of school uniform are neglected. Purpose of this study is to reveal historical origins of black smock and white collar. To achieve this purpose, a qualitative research method was adopted. As a result of the research, it was determined…

  10. The Single Needle Lockstitch Machine. [Setting a Collar.] Module 5.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on sewing collars, one in a series on the single needle lockstitch sewing machine for student self-study, contains three sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final checklist.…

  11. Method and apparatus for neutron radiation monitoring

    International Nuclear Information System (INIS)

    Schwarzmann, A.

    1985-01-01

    A self-calibrated neutron radiation monitor includes a flux responsive element comprised of intrinsic silicon neutron detectors and self-calibration resistors in a single structure. As the resistance of the flux responsive element increases to the value of successive calibration resistors, known increments of flux have been encountered

  12. Neutron Scattering

    International Nuclear Information System (INIS)

    Fayer, Michael J.; Gee, Glendon W.

    2005-01-01

    The neutron probe is a standard tool for measuring soil water content. This article provides an overview of the underlying theory, describes the methodology for its calibration and use, discusses example applications, and identifies the safety issues. Soil water makes land-based life possible by satisfying plant water requirements, serving as a medium for nutrient movement to plant roots and nutrient cycling, and controlling the fate and transport of contaminants in the soil environment. Therefore, a successful understanding of the dynamics of plant growth, nutrient cycling, and contaminant behavior in the soil requires knowledge of the soil water content as well as its spatial and temporal variability. After more than 50 years, neutron probes remain the most reliable tool available for field monitoring of soil water content. Neutron probes provide integrated measurements over relatively large volumes of soil and, with proper access, allow for repeated sampling of the subsurface at the same locations. The limitations of neutron probes include costly and time-consuming manual operation, lack of data automation, and costly regulatory requirements. As more non-radioactive systems for soil water monitoring are developed to provide automated profiling capabilities, neutron-probe usage will likely decrease. Until then, neutron probes will continue to be a standard for reliable measurements of field water contents in soils around the globe

  13. Experimental facilities for calibrations at the dosimetry facility of group 6.5 'Neutron dosimetry' at the Physikalisch-Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Strzelczyk, H.

    1986-07-01

    The mechanical and electrical layout of the ''Dosimetriemessplatz'', a low scattering target area at the accelerator facility is described. Monoenergetic neutrons are generated at the irradiation facility for the research on neutron detectors and dosimeters for radiation protection. The report is aimed to inform dosimetry in particular for those guest's coming from other laboratories. For that purpose a detailed description is given of the mechanical construction, of cable connections and of the monitor system. The feasibitity of data transfer from the system at the target position to the user's system and the mode of acceptance of external data are explained. (orig./HP) [de

  14. Comparison of Aerosol Delivery by Face Mask and Tracheostomy Collar.

    Science.gov (United States)

    Bugis, Alaa A; Sheard, Meryl M; Fink, James B; Harwood, Robert J; Ari, Arzu

    2015-09-01

    The purpose of this study was to compare the performance of a tracheostomy collar, Wright mask, and aerosol mask attached to a jet nebulizer in facilitating aerosolized medication delivery to the lungs. We also compared albuterol delivery with open versus closed fenestration and determined the effect of inspiratory-expiratory ratio (I:E) on aerosol delivery. Albuterol (2.5 mg/3 mL) was administered to an in vitro model consisting of an adult teaching mannequin extrathoracic and upper airway with stoma intubated with an 8-mm fenestrated tracheostomy tube. The cuff was deflated. A collecting filter at the level of the bronchi was connected to a breathing simulator at a tidal volume of 400 mL, breathing frequency of 20 breaths/min, and I:E of 2:1 and 1:2. A jet nebulizer was operated with O2 at 8 L/min. Each interface was tested in triplicate. The flow was discontinued at the end of nebulization. For each test, the nebulizer was attached to a tracheostomy collar with the fenestration open or closed, a Wright mask, or an aerosol mask. Drug was analyzed by spectrophotometry (276 nm). A paired t test and analysis of variance were performed (P mask (4.1 ± 0.6%) and aerosol mask (3.5 ± 0.04%) were both less than with the tracheostomy collar under either condition (P mask (7.2 ± 0.6%), and aerosol mask (6.1 ± 0.5%). In an adult tracheostomy model, the tracheostomy collar delivered more aerosol to the bronchi than the Wright or aerosol mask. An I:E of 2:1 caused greater aerosol deposition compared with an I:E of 1:2. During aerosol administration via a tracheostomy collar, closing the fenestration improved aerosol delivery. Copyright © 2015 by Daedalus Enterprises.

  15. Calculations of neutron spectra after neutron-neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, B E [Gettysburg College, Box 405, Gettysburg, PA 17325 (United States); Stephenson, S L [Gettysburg College, Box 405, Gettysburg, PA 17325 (United States); Howell, C R [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Mitchell, G E [North Carolina State University, Raleigh, NC 27695-8202 (United States); Tornow, W [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Furman, W I [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Lychagin, E V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Muzichka, A Yu [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Nekhaev, G V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Strelkov, A V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Sharapov, E I [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Shvetsov, V N [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation)

    2004-09-01

    A direct neutron-neutron scattering length, a{sub nn}, measurement with the goal of 3% accuracy (0.5 fm) is under preparation at the aperiodic pulsed reactor YAGUAR. A direct measurement of a{sub nn} will not only help resolve conflicting results of a{sub nn} by indirect means, but also in comparison to the proton-proton scattering length, a{sub pp}, shed light on the charge-symmetry of the nuclear force. We discuss in detail the analysis of the nn-scattering data in terms of a simple analytical expression. We also discuss calibration measurements using the time-of-flight spectra of neutrons scattered on He and Ar gases and the neutron activation technique. In particular, we calculate the neutron velocity and time-of-flight spectra after scattering neutrons on neutrons and after scattering neutrons on He and Ar atoms for the proposed experimental geometry, using a realistic neutron flux spectrum-Maxwellian plus epithermal tail. The shape of the neutron spectrum after scattering is appreciably different from the initial spectrum, due to collisions between thermal-thermal and thermal-epithermal neutrons. At the same time, the integral over the Maxwellian part of the realistic scattering spectrum differs by only about 6 per cent from that of a pure Maxwellian nn-scattering spectrum.

  16. Synthetic multi-element standards: a good tool for calibration and quality control of irradiation facilities used for neutron activation analysis

    International Nuclear Information System (INIS)

    Vermaercke, P.

    2007-01-01

    Neutron activation analysis (NAA) is a physical technique used for the absolute measurement of the concentration of substances in solids and liquids. The method uses neutron irradiation which is commonly realised using a nuclear reactor in order to activate (make radioactive) different isotopes of the elements present in the sample. The radionuclides produced in this way emit gamma-rays that are characteristic of the elements present in the sample. Using gamma-ray spectrometry these radionuclides can then be identified and quantified, and hence their concentration in the sample can be determined. Although NAA is a straightforward method it requires a sound control of the many physical parameters involved to obtain accurate results and to guarantee a set accuracy in routine analysis. The accuracy of NAA depends on the specific measurement method used. One can perform NAA in a relative way by co-irradiating a known standard and the unknown sample in the same conditions and by comparing the ratio of gamma-rays they emit. Relative NAA has limited applicability since it requires reference standards with a comparable composition as the unknown. A more generally applicable method is the k0-NAA method. In the k0-NAA method all measurements are relative to the element Au resulting in 198Au when irradiated. The k0-NAA method further relies on the fact that the neutron energy spectrum produced in a given position in the reactor can be parameterised with two parameters: the shape factor of the epithermal neutron flux, indicating the deviation of the epithermal neutron spectrum from the ideal 1/E shape approximated by a 1/E1+a distribution, with E the neutron energy; f: the thermal-to-epithermal neutron flux ratio. The parameters f and a are characteristic for the irradiation facility (reactor and irradiation channels) and may change or fluctuate in time according to the irradiation conditions. The way elements activate (become radioactive) when interacting with neutrons is

  17. Neutron detection technique

    International Nuclear Information System (INIS)

    Oblath, N.S.; Poon, A.W.P.

    2000-01-01

    The Sudbury Neutrino Observatory (SNO) has the ability to measure the total flux of all active flavors of neutrinos using the neutral current reaction, whose signature is a neutron. By comparing the rates of the neutral current reaction to the charged current reaction, which only detects electron neutrinos, one can test the neutrino oscillation hypothesis independent of solar models. It is necessary to understand the neutron detection efficiency of the detector to make use of the neutral current reaction. This report demonstrates a coincidence technique to identify neutrons emitted from the 252 Cf neutron calibration source. The source releases on average four neutrons when a 252 Cf nucleus spontaneously fissions. Each neutron is detected as a separate event when the neutron is captured by a deuteron, releasing a gamma ray of approximately 6.25 MeV. This gamma ray is in turn detected by the photomultiplier tube (PMT) array. By investigating the time and spatial separation between neutron-like events, it is possible to obtain a pure sample of neutrons for calibration study. Preliminary results of the technique applied to two calibration runs are presented

  18. A comparative study of the effect of soft and hard cervical collars on static postural

    Directory of Open Access Journals (Sweden)

    Minoo Khalkhali Zavieh

    2013-01-01

    Full Text Available AbstractBackground and Aim: Using cervical collars is one of the treatment methods for releaving cervical pain. The effect of limb orthotics on proprioception and postural stability has been suggested. There is not sufficient studies about the effect of cervical collars on static and dynamic stability, and the effect of soft and hard collars have not been compared with one another. The objective of this study is investigating and comparing the immediate effect of soft and hard cervical collars on static postural stability in healthy young subjects. Methods & Materials: In standing position on firm surface with closed eyes, both soft and hard collars decreased the stability and there was not any significant difference among collars. In standing positions on soft surface with closed and opened eyes, using none of the soft and hard collars did not change the stability. This quasi experimental study through repeated measure method has been conducted on 65 healthy young male and female college students. Static stability was evaluated by modified Clinical Test for Sensory Interaction and Balance (CTSIB in conditions without collar and by soft and hard cervical collars and were compared between the conditions. Results: Conclusion: Our results suggest that in static conditions, without vision, both collars decrease the stability in healthy young subjects. So considering the evaluation of stability and prevention of balance disturbance during the collar prescription seems to be necessary.

  19. Calibration uncertainty

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Anglov, Thomas

    2002-01-01

    Methods recommended by the International Standardization Organisation and Eurachem are not satisfactory for the correct estimation of calibration uncertainty. A novel approach is introduced and tested on actual calibration data for the determination of Pb by ICP-AES. The improved calibration...

  20. Dependence of Magnetic Field Quality on Collar Supplier and Dimensions in the Main LHC Dipole

    CERN Document Server

    Bellesia, B; Santoni, C; Todesco, E

    2006-01-01

    In order to keep the electro-magnetic forces and to minimize conductor movements, the superconducting coils of the main Large Hadron Collider dipoles are held in place by means of austenitic steel collars. Two suppliers provide the collars necessary for the whole LHC production, which has now reached more than 800 collared coils. In this paper we first assess if the different collar suppliers origin a noticeable difference in the magnetic field quality measured at room temperature. We then analyze the measurements of the collar dimensions carried out at the manufacturers, comparing them to the geometrical tolerances. Finally we use a magneto-static model to evaluate the expected spread in the field components induced by the actual collar dimensions. These spreads are compared to the magnetic measurements at room temperature over the magnet production in order to identify if the collars, rather than other components or assembly process, can account for the measured magnetic field effects. It has been found tha...

  1. Neutron spectra produced by moderating an isotopic neutron source

    International Nuclear Information System (INIS)

    Carrillo Nunnez, Aureliano; Vega Carrillo, Hector Rene

    2001-01-01

    A Monte Carlo study has been carried out to determine the neutron spectra produced by an isotopic neutron source inserted in moderating media. Most devices used for radiation protection have a response strongly dependent on neutron energy. ISO recommends several neutron sources and monoenergetic neutron radiations, but actual working situations have broad spectral neutron distributions extending from thermal to MeV energies, for instance, near nuclear power plants, medical applications accelerators and cosmic neutrons. To improve the evaluation of the dosimetric quantities, is recommended to calibrate the radiation protection devices in neutron spectra which are nearly like those met in practice. In order to complete the range of neutron calibrating sources, it seems useful to develop several wide spectral distributions representative of typical spectra down to thermal energies. The aim of this investigation was to use an isotopic neutron source in different moderating media to reproduce some of the neutron fields found in practice. MCNP code has been used during calculations, in these a 239PuBe neutron source was inserted in H2O, D2O and polyethylene moderators. Moderators were modeled as spheres and cylinders of different sizes. In the case of cylindrical geometry the anisotropy of resulting neutron spectra was calculated from 0 to 2 . From neutron spectra dosimetric features were calculated. MCNP calculations were validated by measuring the neutron spectra of a 239PuBe neutron source inserted in a H2O cylindrical moderator. The measurements were carried out with a multisphere neutron spectrometer with a 6LiI(Eu) scintillator. From the measurements the neutron spectrum was unfolded using the BUNKIUT code and the UTA4 response matrix. Some of the moderators with the source produce a neutron spectrum close to spectra found in actual applications, then can be used during the calibration of radiation protection devices

  2. Determination of Th and U by neutron activation for gamma spectrometry calibration in situ; Determinacion de Th y U por activacion neutronica para calibracion de espectrometria gamma in situ

    Energy Technology Data Exchange (ETDEWEB)

    Nava M, F.; Rios M, C.; Mireles G, F.; Saucedo A, S.; Davila R, I.; Pinedo, J. L. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas (Mexico); Landsberger, S., E-mail: iqnava@hotmail.com [University of Texas at Austin, Nuclear Engineering Teaching Laboratory, Pickle Research Campus, R9000 Austin, Texas 78712 (United States)

    2012-10-15

    Using the analysis by neutron activation to determine the profile of the thorium and uranium concentration calibration factors were obtained for their use in the gamma spectrometry in situ. Three sites were selected (San Ramon, Villa de Cos y la Zacatecana) and the analysis by activation was development in the Laboratory of Nuclear Engineering Teaching of the Texas University in Austin with the nuclear reactor Ut-TRIGA. Starting from the gamma spectra in situ, the areas of normalized photo-pick of the radioisotopes were: {sup 208}Tl and {sup 228}Ac for the thorium series and {sup 214}Pb and {sup 214}Bi for the uranium series. The averages of the factors found in units of (cpm/Bq/Kg) are of 105.63{+-}8.32 and 75.87{+-}4.61 for the thorium and uranium, respectively. (Author)

  3. Extension of the calibration of an NE-213 liquid scintillator based pulse height response spectrometer up to 18 MeV neutron energy and leakage spectrum measurements on bismuth at 8 MeV and 18 MeV neutron energies

    International Nuclear Information System (INIS)

    Fenyvesi, A.; Valastyan, I.; Olah, L.; Csikai, J.; Plompen, A.; Jaime, R.; Loevestam, G.; Semkova, V.

    2011-01-01

    Monoenergetic neutrons were produced at the Van de Graaff accelerator of the EC-JRC-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium). An air-jet cooled D_2-gas target (1.2 bar, ΔE_d = 448 keV) was bombarded with E_d =4976 keV deuterons to produce neutrons up to E_n = 8 MeV energy via the D(d,n)"3He reaction. Higher energy neutrons up to E_n = 18 MeV were produced via the T(d,n)"4He reaction by bombarding a TiT target with E_d =1968 keV deuterons. Pulse height spectra were measured at different neutron energies from E_n = 8 MeV up to E_n = 18 MeV with the NE-213 liquid scintillator based Pulse Height Response Spectrometer (PHRS) of UD-IEP. The energy calibration of the PHRS system has been extended up to E_n = 18 MeV. Pulse height spectra induced by gamma photons have been simulated by the GRESP7 code. Neutron induced pulse height spectra have been simulated by the NRESP7 and MCNP-POLIMI codes. Comparison of the results of measurements and simulations enables the improvement of the parameter set of the function used by us to describe the light output dependence of the resolution of the PHRS system at light outputs of L > 2 light units. Also, it has been shown that the derivation method for unfolding neutron spectra from measured pulse height spectra performs well when relative measurements are done up to E_n = 18 MeV neutron energy. For matrix unfolding purposes, the NRESP7 code has to be preferred to calculate the pulse height response matrix of the PHRS system. Leakage spectra of neutrons behind bismuth slabs of different thicknesses have been measured with the PHRS system by using monoenergetic neutrons. The maximum slab thickness was d = 14 cm. Simulations of the measurements have been carried out with the MCNP-4c code. The necessary nuclear cross-sections were taken from the from the ENDF/B-VII and JEFF.3.1 data libraries. For both libraries, the agreement of measured and simulated neutron spectra is good for the 5 MeV ≤ En ≤ 18 Me

  4. Calibration factor or calibration coefficient?

    International Nuclear Information System (INIS)

    Meghzifene, A.; Shortt, K.R.

    2002-01-01

    Full text: The IAEA/WHO network of SSDLs was set up in order to establish links between SSDL members and the international measurement system. At the end of 2001, there were 73 network members in 63 Member States. The SSDL network members provide calibration services to end-users at the national or regional level. The results of the calibrations are summarized in a document called calibration report or calibration certificate. The IAEA has been using the term calibration certificate and will continue using the same terminology. The most important information in a calibration certificate is a list of calibration factors and their related uncertainties that apply to the calibrated instrument for the well-defined irradiation and ambient conditions. The IAEA has recently decided to change the term calibration factor to calibration coefficient, to be fully in line with ISO [ISO 31-0], which recommends the use of the term coefficient when it links two quantities A and B (equation 1) that have different dimensions. The term factor should only be used for k when it is used to link the terms A and B that have the same dimensions A=k.B. However, in a typical calibration, an ion chamber is calibrated in terms of a physical quantity such as air kerma, dose to water, ambient dose equivalent, etc. If the chamber is calibrated together with its electrometer, then the calibration refers to the physical quantity to be measured per electrometer unit reading. In this case, the terms referred have different dimensions. The adoption by the Agency of the term coefficient to express the results of calibrations is consistent with the 'International vocabulary of basic and general terms in metrology' prepared jointly by the BIPM, IEC, ISO, OIML and other organizations. The BIPM has changed from factor to coefficient. The authors believe that this is more than just a matter of semantics and recommend that the SSDL network members adopt this change in terminology. (author)

  5. Habitat Selection and Activity Pattern of GPS Collared Sumateran Tigers

    Directory of Open Access Journals (Sweden)

    Dolly Priatna

    2012-12-01

    Full Text Available Although translocation has been used in mitigating human-carnivore conflict for decades, few studies have been conducted on the behavioral ecology of released animals. Such information is necessary in the context of sustainable forest management. In this study we determine the type of land cover used as main habitat and examine the activity pattern of translocated tigers. Between 2008 and 2010 we captured six conflict tigers and translocated them 74-1,350 km from their capture sites in Sumatera. All tigers were fitted with global positioning system (GPS collars. The collars were set to fix 24-48 location coordinates per day.  All translocated tigers showed a preference for a certain habitat type within their new home range, and tended to select the majority of natural land cover type within the landscape as their main habitat, but the availability of natural forest habitat within the landscape remains essensial for their survival. The activity of male translocated tigers differed significantly between the six time intervals of 24 hours, and their most active periods were in the afternoon (14:00-18:00 hours and in the evening (18:00-22:00 hours. Despite being preliminary, the findings of this study-which was the first such study conducted in Sumatera-highlight the conservation value of tiger translocation and provide valuable information for improving future management of conflict tigers.Keywords: activity pattern, GPS collars, habitat selection, sumateran tiger, translocation

  6. HDM model magnet mechanical behavior with high manganese steel collars

    International Nuclear Information System (INIS)

    Snyder, J.R.

    1994-01-01

    Westinghouse Electric Corporation (WEC) is presently under contract to the SSCL to design, develop, fabricate, and deliver superconducting dipole magnets for the High Energy Booster (HEB). As a first step toward these objectives SSCL supplied a design for short model magnets of 1.8 m in length (DSB). This design was used as a developmental tool for all phases of engineering and fabrication. Mechanical analysis of the HDM (High Energy Booster Dipole Magnets) model magnet design as specified by SSCL was performed with the following objectives: (1) to develop a thorough understanding of the design; (2) to review and verify through analytical and numerical analyses the SSCL model magnet design; (3) to identify any deficiencies that would violate design parameters specified in the HDM Design Requirements Document. A detailed analysis of the model magnet mechanical behavior was pursued by constructing a quarter section finite element model and solving with the ANSYS finite element code. Collar materials of Nitronic-40 and High-Manganese steel were both considered for the HEB model magnet program with the High-Manganese being the final selection. The primary mechanical difference in the two materials is the much lower thermal contraction of the High-Manganese steel. With this material the collars will contract less than the enclosing yoke producing an increased collar yoke interference during cooldown

  7. Microcomputerized neutron moisture gauge

    International Nuclear Information System (INIS)

    Liu Shengkang; Mei Yu

    1987-01-01

    A microcomputerized neutron moisture gauge is introduced. This gauge consists of a neutron moisture sensor and instruments. It is developed from the neutron moisture gauge for concrete mixer. A TECH-81 single card microcomputer is used for count, computation and display. It has the function of computing compensated quantity of sand. It can acquire the data from several neutron sensors by the multichanneling sampling, therefore it can measure moisture values of sand in several hoppers simultaneously. The precision of the static state calibration curve is 0.24% wt. The error limits of the dynamic state check is < 0.50% wt

  8. MESSENGER E/V/H GRNS 3 NEUTRON SPECTROMETER CDR V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER Neutron Spectrometer (NS) calibrated data records (CDRs). The NS experiment is a neutron spectrometer...

  9. Increased Executive Functioning, Attention, and Cortical Thickness in White-Collar Criminals

    Science.gov (United States)

    Raine, Adrian; Laufer, William S.; Yang, Yaling; Narr, Katherine L.; Thompson, Paul; Toga, Arthur W.

    2011-01-01

    Very little is known on white collar crime and how it differs to other forms of offending. This study tests the hypothesis that white collar criminals have better executive functioning, enhanced information processing, and structural brain superiorities compared to offender controls. Using a case-control design, executive functioning, orienting, and cortical thickness was assessed in 21 white collar criminals matched with 21 controls on age, gender, ethnicity, and general level of criminal offending. White collar criminals had significantly better executive functioning, increased electrodermal orienting, increased arousal, and increased cortical gray matter thickness in the ventromedial prefrontal cortex, inferior frontal gyrus, somatosensory cortex, and the temporal-parietal junction compared to controls. Results, while initial, constitute the first findings on neurobiological characteristics of white-collar criminals It is hypothesized that white collar criminals have information-processing and brain superiorities that give them an advantage in perpetrating criminal offenses in occupational settings. PMID:22002326

  10. Calibration of the Lawrence Livermore National Laboratory Passive-Active Neutron Drum Shuffler for Measurement of Highly Enriched Uranium in Oxides within DOE-STD-3013-2000 Containers

    International Nuclear Information System (INIS)

    Mount, M E; O'Connell, W J

    2005-01-01

    Lawrence Livermore National Laboratory (LLNL) uses the LLNL passive-active neutron drum (PAN) shuffler (Canberra Model JCC-92) for accountability measurement of highly enriched uranium (HEU) oxide and HEU in mixed uranium-plutonium (U-Pu) oxide. In June 2002, at the 43rd Annual Meeting of the Institute of Nuclear Material Management, LLNL reported on an extensive effort to calibrate this shuffler, based on standards measurements and extensive simulations, for HEU oxides and mixed U-Pu oxides in thin-walled primary and secondary containers. In August 2002, LLNL began to also use DOE-STD-3013-2000 containers for HEU oxide and mixed U-Pu oxide. These DOE-STD-3013-2000 containers are comprised of a stainless steel convenience can enclosed in welded stainless steel primary and secondary containers. Compared to the double thin-walled containers, the DOE-STD-3013-2000 containers have substantially thicker walls, and the density of materials in these containers was found to extend over a greater range (1.35 g/cm 3 to 4.62 g/cm 3 ) than foreseen for the double thin-walled containers. Further, the DOE-STD-3013-2000 Standard allows for oxides containing at least 30 wt% Pu plus U whereas the calibration algorithms for thin-walled containers were derived for virtually pure HEU or mixed U-Pu oxides. An initial series of Monte Carlo simulations of the PAN shuffler response to given quantities of HEU oxide and mixed U-Pu oxide in DOE-STD-3013-2000 containers was generated and compared with the response predicted by the calibration algorithms for thin-walled containers. Results showed a decrease on the order of 10% in the count rate, and hence a decrease in the calculated U mass for measured unknowns, with some varying trends versus U mass. Therefore a decision was made to develop a calibration algorithm for the PAN shuffler unique to the DOE-STD-3013-2000 container. This paper describes that effort and selected unknown item measurement results

  11. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Otto, T.

    1997-01-01

    In 1996, the Dosimetry and Calibration Section was, as in previous years, mainly engaged in routine tasks: the distribution of over 6000 dosimeters (with a total of more than 10,000 films) every two months and the calibration of about 900 fixed and mobile instruments used in the radiation survey sections of RP group. These tasks were, thanks to an experienced team, well mastered. Special efforts had to be made in a number of areas to modernize the service or to keep it in line with new prescriptions. The Individual Dosimetry Service had to assure that CERN's contracting firms comply with the prescriptions in the Radiation Safety Manual (1996) that had been inspired by the Swiss Ordinance of 1994: Companies must file for authorizations with the Swiss Federal Office for Public Health requiring that in every company an 'Expert in Radiation Protection' be nominated and subsequently trained. CERN's Individual Dosimetry Service is accredited by the Swiss Federal Authorities and works closely together with other, similar services on a rigorous quality assurance programme. Within this framework, CERN was mandated to organize this year the annual Swiss 'Intercomparison of Dosimeters'. All ten accredited dosimetry services - among others those of the Paul Scherrer Institute (PSI) in Villigen and of the four Swiss nuclear power stations - sent dosimeters to CERN, where they were irradiated in CERN's calibration facility with precise photon doses. After return to their origin they were processed and evaluated. The results were communicated to CERN and were compared with the originally given doses. A report on the results was subsequently prepared and submitted to the Swiss 'Group of Experts on Personal Dosimetry'. Reference monitors for photon and neutron radiation were brought to standard laboratories to assure the traceability of CERN's calibration service to the fundamental quantities. For photon radiation, a set of ionization chambers was calibrated in the reference field

  12. Neutron stars

    International Nuclear Information System (INIS)

    Irvine, J.M.

    1978-01-01

    The subject is covered in chapters entitled: introduction (resume of stellar evolution, gross characteristics of neutron stars); pulsars (pulsar characteristics, pulsars as neutron stars); neutron star temperatures (neutron star cooling, superfluidity and superconductivity in neutron stars); the exterior of neutron stars (the magnetosphere, the neutron star 'atmosphere', pulses); neutron star structure; neutron star equations of state. (U.K.)

  13. A beaded collar for dual micro GPS/VHF transmitter attachment to nutria

    Science.gov (United States)

    Haramis, G.M.; White, T.S.

    2011-01-01

    We report on the development of an approximately 85-g beaded collar for dual micro GPS/VHF transmitter attachment to semi-aquatic nutria (Myocastor coypus). Prototype collars were tested on captive nutria and refined during field trials. Central to the design was novel use of the VHF transmitter antenna as a collar. A circular collar was formed by passing the 44-cm antenna cable through a pre-made hole in the transmitter, leaving an approximately 16-cm upright antenna. GPS units were mounted separately via a hole in the base of each unit. For good satellite contact, GPS units (28 g) were maintained at the nape of the neck by counterbalance of the heavier VHF transmitters (50 g) positioned under the neck. To reduce friction, we lined the collar with alternate-sized plastic and, later, more durable nylon beads. The final collar configuration was worn for approximately 1 month deployments with only minor neck abrasion; one collar was worn successfully for 5 months. Foot entanglement remained the greatest risk of injury from the collar. By fitting collars tightly, we reduced the incidence of foot entanglement to 2 of 33 deployments (6%). Successful GPS tracks were acquired on 29 of 33 deployments (88%).

  14. Organizational justice is related to heart rate variability in white-collar workers, but not in blue-collar workers-findings from a cross-sectional study.

    Science.gov (United States)

    Herr, Raphael M; Bosch, Jos A; van Vianen, Annelies E M; Jarczok, Marc N; Thayer, Julian F; Li, Jian; Schmidt, Burkhard; Fischer, Joachim E; Loerbroks, Adrian

    2015-06-01

    Perceived injustice at work predicts coronary heart disease. Vagal dysregulation represents a potential psychobiological pathway. We examined associations between organizational justice and heart rate variability (HRV) indicators. Grounded in social exchange and psychological contract theory, we tested predictions that these associations are more pronounced among white-collar than among blue-collar workers. Cross-sectional data from 222 blue-collar and 179 white-collar men were used. Interactional and procedural justice were measured by questionnaire. Ambulatory HRV was assessed across 24 h. Standardized regression coefficients (β) were calculated. Among white-collar workers, interactional justice showed positive relationships with 24-h HRV, which were strongest during sleeping time (adjusted βs≥0.26; p values≤0.01). No associations were found for blue-collar workers. A comparable but attenuated pattern was observed for procedural justice. Both dimensions of organizational injustice were associated with lowered HRV among white-collar workers. The impact of justice and possibly its association with health seems to differ by occupational groups.

  15. Hypospadias repair with the glanular-frenular collar (GFC) technique.

    Science.gov (United States)

    Özbey, Hüseyin; Etker, Şeref

    2017-02-01

    In the normal human penis, the glans wings merge in the midline ventrally, but are separated by the 'septum glandis' in conjunction with the frenulum. The frenulum is also included in the formation of the distal (glanular and subcoronal) urethra, which has a special part known as the 'fossa navicularis'. This has inspired a hypospadias repair technique that simulates the development of the glanular and subcoronal urethra, which can be incorporated into the repair of all cases of hypospadias. A total of 121 patients with varying degrees of hypospadias underwent surgery with the described technique: a Y-V plasty was used to dissect the inner foreskin, in a fashion that allowed for its ventral mobilization as a frenular mucosal collar. After tubularization of the proximal urethra, a partial spongioplasty was performed that extended up to the subcoronal level. The glans wings were approximated only at their outermost convexities, with a couple of subepithelial sutures, leaving a slit for the meatus. The cleft-like area between the split wings of the glans penis was filled with the terminal ends of the spongiosum and the dartos of the mucosal collar, which converged to form a septum and a neo-frenulum (glanular-frenular collar, GFC). The midline skin closure of the ventral collar and the circumferential foreskin closure was completed as usual. At a mean follow-up of 10 months, two patients developed urethral fistula (2%), six had meatal stenosis (5%), and two had glans dehiscence (2%) that resulted in meatal retraction. Overall, patients had a cosmetically satisfying appearance (Figure). Forty-one received secondary circumcision; the parents of 80 (66%) patients were satisfied with the final foreskin appearance obtained with this method. The split wings of the glans penis or so-called ventral cleft between the glans wings that accommodate the frenulum is part of normal anatomy. Hence, in hypospadias surgery, the approximated glans wings should allow for ventral support

  16. White-collar workers' hemodynamic responses during working hours.

    Science.gov (United States)

    Liu, Xinxin; Iwakiri, Kazuyuki; Sotoyama, Midori

    2017-08-08

    In the present study, two investigations were conducted at a communication center, to examine white-collar workers' hemodynamic responses during working hours. In investigation I, hemodynamic responses were measured on a working day; and in investigation II, cardiovascular responses were verified on both working and non-working days. In investigation I, blood pressure, cardiac output, heart rate, stroke volume, and total peripheral resistance were measured in 15 workers during working hours (from 9:00 am to 18:00 pm) on one working day. Another 40 workers from the same workplace participated in investigation II, in which blood pressure and heart rate were measured between the time workers arose in the morning until they went to bed on 5 working days and 2 non-working days. The results showed that blood pressure increased and remained at the same level during working hours. The underlying hemodynamics of maintaining blood pressure, however, changed between the morning and the afternoon on working days. Cardiac responses increased in the afternoon, suggesting that cardiac burdens increase in the afternoon on working days. The present study suggested that taking underlying hemodynamic response into consideration is important for managing the work-related cardiovascular burden of white-collar workers.

  17. Neutron ion temperature measurement

    International Nuclear Information System (INIS)

    Strachan, J.D.; Hendel, H.W.; Lovberg, J.; Nieschmidt, E.B.

    1986-11-01

    One important use of fusion product diagnostics is in the determination of the deuterium ion temperature from the magnitude of the 2.5 MeV d(d,n) 3 He neutron emission. The detectors, calibration methods, and limitations of this technique are reviewed here with emphasis on procedures used at PPPL. In most tokamaks, the ion temperature deduced from neutrons is in reasonable agreement with the ion temperature deduced by other techniques

  18. Ovarian folliculogenesis in collared peccary: Pecari tajacu (Artiodactyla: Tayassuidae

    Directory of Open Access Journals (Sweden)

    Diva Anelie Guimarães

    2012-03-01

    Full Text Available The sustainability and production of collared peccary (Pecari tajacu has been studied in the last few years; however, further information on its reproduction is necessary for breeding systems success. Understanding folliculogenesis aspects will contribute to effective reproductive biotechniques, which are useful in the preservation and production of wildlife. The aim of this study was to evaluate the ovarian folliculogenesis in collared peccary. Ovaries from six adult females of collared peccary were obtained through ovariectomy and analyzed. These were fixed in aqueous Bouin’s solution and sectioned into 7μm slices, stained with hematoxilin-eosin and analyzed by light microscopy. The number of pre-antral and antral follicles per ovary was estimated using the Fractionator Method. The follicles, oocytes and oocyte nuclei were measured using an ocular micrometer. Results showed that the length, width, thickness, weight, and the gross anatomy of the right and left ovaries were not significantly different. However, the mean number of corpora lutea was different between the phases of the estrous cycle (pLa sustentabilidad y la producción de pecarí de collar (Pecari tajacu han sido estudiados en los últimos años, sin embargo, más información sobre su reproducción es necesaria para el éxito de los sistemas de crianza . La comprensión de los aspectos relacionados con la foliculogénesis contribuirá con la aplicación de biotécnicas de reproducción, las cuales son útiles en la preservación y la producción de la vida silvestre. El objetivo de este estudio fue obtener datos sobre la población folicular del ovario de pecarí de collar. En relación con la población folicular en el ovario derecho, los valores de los folículos primordiales y primarios fueron similares, pero se observó que había una diferencia significativa (p<0.05 con el secundario. En el ovario izquierdo, la fase folicular presentó diferencias significativas (p<0

  19. 78 FR 4167 - Certain Electronic Bark Control Collars; Notice of Receipt of Complaint; Solicitation of Comments...

    Science.gov (United States)

    2013-01-18

    ... INTERNATIONAL TRADE COMMISSION [Docket No. 2932] Certain Electronic Bark Control Collars; Notice.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International Trade Commission has received a complaint entitled Certain Electronic Bark Control Collars, DN 2932; the...

  20. Advantages of heavy metal collars in directional drilling and deviation control

    International Nuclear Information System (INIS)

    Bradley, W.B.; Murphey, C.E.; McLamore, R.T.; Dickson, L.L.

    1976-01-01

    A heavy, stiff-bottom drill collar can substantially improve deviation performance, theoretically increasing penetration rates by 50 to 100 percent in deviation-prone areas. This paper presents the underlying theory, practical charts on performance characteristics, and Shell Development Co.'s experience in fabricating and field testing two depleted-uranium alloy, heavy metal collars

  1. Does patency after a vein collar and PTFE-bypass depend on sex and age?

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    Randomized studies evaluating the effect of a vein collar at the distal anastomosis of PTFE-grafts show conflicting results. The study of the Joint Vascular Research Group (JVRG) of UK found improved primary patency while the Scandinavian Miller Collar Study (SCAMICOS) found neither any effect...

  2. GPS radio collar 3D performance as influenced by forest structure and topography

    Science.gov (United States)

    R. Scott Gamo; Mark A. Rumble; Fred Lindzey; Matt Stefanich

    2000-01-01

    Global Positioning System (GPS) telemetry enables biologists to obtain accurate and systematic locations of animals. Vegetation can block signals from satellites to GPS radio collars. Therefore, a vegetation dependent bias to telemetry data may occur which if quantified, could be accounted for. We evaluated the performance of GPS collars in 6 structural stage...

  3. Characterization of the neutron sources storage pool of the Neutron Standards Laboratory, using Montecarlo Techniques

    International Nuclear Information System (INIS)

    Campo Blanco, X.

    2015-01-01

    The development of irradiation damage resistant materials is one of the most important open fields in the design of experimental facilities and conceptual nucleoelectric fusion plants. The Neutron Standards Laboratory aims to contribute to this development by allowing the neutron irradiation of materials in its calibration neutron sources storage pool. For this purposes, it is essential to characterize the pool itself in terms of neutron fluence and spectra due to the calibration neutron sources. In this work, the main features of this facility are presented and the characterization of the storage pool is carried out. Finally, an application is shown of the obtained results to the neutron irradiation of material.

  4. Decent Work in the Chinese Apparel Industry: Comparative Analysis of Blue-Collar and White-Collar Garment Workers

    Directory of Open Access Journals (Sweden)

    Caixia Chen

    2017-08-01

    Full Text Available Addressing labor issues in the apparel industry is significantly important due to customers’ increasing awareness of poor working conditions and growing labor crises in apparel production locations worldwide. Decent work is a key element to achieving fair and harmonious employment, but is not always evident in global apparel production networks. This study examines the working conditions in China’s garment manufacturing industry, which employs more than 10 million workers. A survey was administered to 313 blue-collar workers and 228 white-collar workers on issues related to decent work, including workers’ concerns, satisfaction levels and attitudes towards decent work. Regression analysis showed that workers’ attitudes are significantly related to age, education level, service length and monthly wage. Gap analysis revealed poor understanding of decent work and low satisfaction with primary indicators of decent work. However, results suggest that workers increasingly value soft factors and the overall work experience, not only financial benefits. Cluster analysis identified four clusters of workers. This study contributes to understanding garment worker perceptions of decent work and provides implications for the operationalization of decent work in China’s garment manufacturing industry.

  5. CERN Radiation Protection (RP) calibration facilities

    CERN Document Server

    AUTHOR|(CDS)2082069; Macián-Juan, Rafael

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelera...

  6. Calibration device for wide range monitor

    International Nuclear Information System (INIS)

    Kodoku, Masaya; Sato, Toshifumi.

    1989-01-01

    The calibration device for a wide range monitor according to the present invention can continuously calibrate the entire counting regions of a wide range monitor. The wide range monitor detect the reactor power in the neutron source region by means of a pulse counting method and detects the reactor power in the intermediate region by means of a cambell method. A calibration signal outputting means is disposed for continuously outputting, as such calibration signals, pulse number varying signals in which the number of pulses per unit time varies depending on the reactor power in the neutron source region to be simulated and amplitude square means varying signal in which the mean square value of amplitude varies depending on the reactor power in the intermediate region to be simulated. By using both of the calibration signals, calibration can be conducted for the nuclear reactor power in the neutron source region and the intermediate region even if the calibration is made over two regions, further, calibration for the period present over the two region can be conducted easily as well. (I.S.)

  7. Neutronic analysis of JET external neutron monitor response

    Energy Technology Data Exchange (ETDEWEB)

    Snoj, Luka, E-mail: luka.snoj@ijs.si [Reactor Physics Division, Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Lengar, Igor; Čufar, Aljaž [Reactor Physics Division, Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Syme, Brian; Popovichev, Sergey [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, OX14 3DB, United Kingdom (United Kingdom); Batistoni, Paola [ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati, Roma (Italy); Conroy, Sean [VR Association, Uppsala University, Department of Physics and Astronomy, PO Box 516, SE-75120 Uppsala (Sweden)

    2016-11-01

    Highlights: • We model JET tokamak containing JET remote handling system. • We investigate effect of remote handling system on external neutron monitor response. • Remote handling system correction factors are calculated. • Integral correction factors are relatively small, i.e up to 8%. - Abstract: The power output of fusion devices is measured in terms of the neutron yield which relates directly to the fusion yield. JET made a transition from Carbon wall to ITER-Like Wall (Beryllium/Tungsten/Carbon) during 2010–11. Absolutely calibrated measurement of the neutron yield by JET neutron monitors was ensured by direct measurements using a calibrated {sup 252}Cf neutron source (NS) deployed by the in-vessel remote handling system (RHS) inside the JET vacuum vessel. Neutronic calculations were required in order to understand the neutron transport from the source in the vacuum vessel to the fission chamber detectors mounted outside the vessel on the transformer limbs of the tokamak. We developed a simplified computational model of JET and the JET RHS in Monte Carlo neutron transport code MCNP and analyzed the paths and structures through which neutrons reach the detectors and the effect of the JET RHS on the neutron monitor response. In addition we performed several sensitivity studies of the effect of substantial massive structures blocking the ports on the external neutron monitor response. As the simplified model provided a qualitative picture of the process only, some calculations were repeated using a more detailed full 3D model of the JET tokamak.

  8. Tracking maize pollen development by the Leaf Collar Method.

    Science.gov (United States)

    Begcy, Kevin; Dresselhaus, Thomas

    2017-12-01

    An easy and highly reproducible nondestructive method named the Leaf Collar Method is described to identify and characterize the different stages of pollen development in maize. In plants, many cellular events such as meiosis, asymmetric cell division, cell cycle regulation, cell fate determination, nucleus movement, vacuole formation, chromatin condensation and epigenetic modifications take place during pollen development. In maize, pollen development occurs in tassels that are confined within the internal stalk of the plant. Hence, identification of the different pollen developmental stages as a tool to investigate above biological processes is impossible without dissecting the entire plant. Therefore, an efficient and reproducible method is necessary to isolate homogeneous cell populations at individual stages throughout pollen development without destroying the plant. Here, we describe a method to identify the various stages of pollen development in maize. Using the Leaf Collar Method in the maize inbreed line B73, we have determined the duration of each stage from pollen mother cells before meiosis to mature tricellular pollen. Anther and tassel size as well as percentage of pollen stages were correlated with vegetative stages, which are easily recognized. The identification of stage-specific genes indicates the reproducibility of the method. In summary, we present an easy and highly reproducible nondestructive method to identify and characterize the different stages of pollen development in maize. This method now opens the way for many subsequent physiological, morphological and molecular analyses to study, for instance, transcriptomics, metabolomics, DNA methylation and chromatin patterns during normal and stressful conditions throughout pollen development in one of the economically most important grass species.

  9. Monitoring distances travelled by horses using GPS tracking collars.

    Science.gov (United States)

    Hampson, B A; Morton, J M; Mills, P C; Trotter, M G; Lamb, D W; Pollitt, C C

    2010-05-01

    The aims of this work were to (1) develop a low-cost equine movement tracking collar based on readily available components, (2) conduct preliminary studies assessing the effects of both paddock size and internal fence design on the movements of domestic horses, with and without foals at foot, and (3) describe distances moved by mares and their foals. Additional monitoring of free-ranging feral horses was conducted to allow preliminary comparisons with the movement of confined domestic horses. A lightweight global positioning system (GPS) data logger modified from a personal/vehicle tracker and mounted on a collar was used to monitor the movement of domestic horses in a range of paddock sizes and internal fence designs for 6.5-day periods. In the paddocks used (0.8-16 ha), groups of domestic horses exhibited a logarithmic response in mean daily distance travelled as a function of increasing paddock size, tending asymptotically towards approximately 7.5 km/day. The distance moved by newborn foals was similar to their dams, with total distance travelled also dependent on paddock size. Without altering available paddock area, paddock design, with the exception of a spiral design, did not significantly affect mean daily distance travelled. Feral horses (17.9 km/day) travelled substantially greater mean daily distances than domestic horses (7.2 km/day in 16-ha paddock), even when allowing for larger paddock size. Horses kept in stables or small yards and paddocks are quite sedentary in comparison with their feral relatives. For a given paddock area, most designs did not significantly affect mean daily distance travelled.

  10. Instrumentation calibration

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-08-01

    Procedures for the calibration of different types of laboratory equipment are described. Provisions for maintaining the integrity of reference and working standards traceable back to a national standard are discussed. Methods of validation and certification methods are included. An appendix lists available publications and services of national standardizing agencies

  11. Manufacturing Gender Inequality in the New Economy: High School Training for Work in Blue-Collar Communities.

    Science.gov (United States)

    Sutton, April; Bosky, Amanda; Muller, Chandra

    2016-08-01

    Tensions between the demands of the knowledge-based economy and remaining, blue-collar jobs underlie renewed debates about whether schools should emphasize career and technical training or college-preparatory curricula. We add a gendered lens to this issue, given the male-dominated nature of blue-collar jobs and women's greater returns to college. Using the ELS:2002, this study exploits spatial variation in school curricula and jobs to investigate local dynamics that shape gender stratification. Results suggest a link between high school training and jobs in blue-collar communities that structures patterns of gender inequality into early adulthood. Although high school training in blue-collar communities reduced both men's and women's odds of four-year college enrollment, it had gender-divergent labor market consequences. Men in blue-collar communities took more blue-collar courses, had higher rates of blue-collar employment, and earned similar wages relative to otherwise comparable men from non-blue-collar communities. Women were less likely to work and to be employed in professional occupations, and they suffered severe wage penalties relative to their male peers and women from non-blue-collar communities. These relationships were due partly to high schools in blue-collar communities offering more blue-collar and fewer advanced college-preparatory courses. This curricular tradeoff may benefit men, but it appears to disadvantage women.

  12. Polarized neutrons

    International Nuclear Information System (INIS)

    Williams, W.G.

    1988-01-01

    The book on 'polarized neutrons' is intended to inform researchers in condensed matter physics and chemistry of the diversity of scientific problems that can be investigated using polarized neutron beams. The contents include chapters on:- neutron polarizers and instrumentation, polarized neutron scattering, neutron polarization analysis experiments and precessing neutron polarization. (U.K.)

  13. Neutron--neutron logging

    International Nuclear Information System (INIS)

    Allen, L.S.

    1977-01-01

    A borehole logging tool includes a steady-state source of fast neutrons, two epithermal neutron detectors, and two thermal neutron detectors. A count rate meter is connected to each neutron detector. A first ratio detector provides an indication of the porosity of the formation surrounding the borehole by determining the ratio of the outputs of the two count rate meters connected to the two epithermal neutron detectors. A second ratio detector provides an indication of both porosity and macroscopic absorption cross section of the formation surrounding the borehole by determining the ratio of the outputs of the two count rate meters connected to the two thermal neutron detectors. By comparing the signals of the two ratio detectors, oil bearing zones and salt water bearing zones within the formation being logged can be distinguished and the amount of oil saturation can be determined. 6 claims, 2 figures

  14. HENC performance evaluation and plutonium calibration

    International Nuclear Information System (INIS)

    Menlove, H.O.; Baca, J.; Pecos, J.M.; Davidson, D.R.; McElroy, R.D.; Brochu, D.B.

    1997-10-01

    The authors have designed a high-efficiency neutron counter (HENC) to increase the plutonium content in 200-L waste drums. The counter uses totals neutron counting, coincidence counting, and multiplicity counting to determine the plutonium mass. The HENC was developed as part of a Cooperative Research and Development Agreement between the Department of Energy and Canberra Industries. This report presents the results of the detector modifications, the performance tests, the add-a-source calibration, and the plutonium calibration at Los Alamos National Laboratory (TA-35) in 1996

  15. Factors associated with blue-collar workers' risk perception of cardiovascular disease.

    Science.gov (United States)

    Hwang, Won Ju; Hong, Oisaeng; Kim, Mi Ja

    2012-12-01

    The purpose of this study was to investigate the contribution of actual cardiovascular disease (CVD) risk, as well as, individual, psychosocial, and work-related factors as predictors of CVD risk perception among Korean blue-collar workers. The participants were 238 Korean blue-collar workers who worked in small companies. Data were collected through a survey; anthropometric and blood pressure measures; and blood sampling for lipid levels. Blue-collar workers had high actual CVD risk and low CVD risk perception. The significant predictors of risk perception included perceived health status, alcohol consumption, knowledge of CVD risk, actual CVD risk, decision latitude, and shift work. The model explained 26% of the variance in CVD risk perception. The result suggests when occupational health nurses are giving routine health examination in small companies, they can enhance CVD risk perception in blue-collar workers by providing essential information about CVD risk factors and personal counseling on the individual worker's CVD risk status.

  16. An integrative review: work environment factors associated with physical activity among white-collar workers.

    Science.gov (United States)

    Lin, Yun-Ping; McCullagh, Marjorie C; Kao, Tsui-Sui; Larson, Janet L

    2014-02-01

    The purpose of this review is to synthesize the research evidence for the role of the work environment-workplace physical activity policies and resources and job strain factors-in explaining physical activity in white-collar workers. White-collar workers are at risk for developing a sedentary lifestyle, which contributes to all-cause mortality. Understanding how work environment can influence worker physical activity is important for the development of effective interventions. We reviewed 15 research articles that describe the relationship between work environment factors and physical activity in predominantly white-collar workers. Relatively consistent evidence was found for the effects of supportive workplace policies and resources. Weak evidence was found for the effects of job strain. Both work environment factors have the potential to influence physical activity but require further exploration to fully understand their contribution to physical activity in white-collar workers. Limitations and implications are discussed.

  17. Augmenting the osseointegration of endoprostheses using laser-sintered porous collars: an in vivo study.

    Science.gov (United States)

    Mumith, A; Coathup, M; Chimutengwende-Gordon, M; Aston, W; Briggs, T; Blunn, G

    2017-02-01

    Massive endoprostheses rely on extra-cortical bone bridging (ECBB) to enhance fixation. The aim of this study was to investigate the role of selective laser sintered (SLS) porous collars in augmenting the osseointegration of these prostheses. The two novel designs of porous SLS collars, one with small pores (Ø700 μm, SP) and one with large pores (Ø1500 μm, LP), were compared in an ovine tibial diaphyseal model. Osseointegration of these collars was compared with that of a clinically used solid, grooved design (G). At six months post-operatively, the ovine tibias were retrieved and underwent radiological and histological analysis. Porous collars provided a significantly greater surface (p direct ingrowth of more bone and are better than current designs which rely on surface ongrowth and ECBB. Cite this article: Bone Joint J 2017;99-B:276-82. ©2017 The British Editorial Society of Bone & Joint Surgery.

  18. Cervical collar or physiotherapy versus wait and see policy for recent onset cervical radiculopathy: randomised trial.

    NARCIS (Netherlands)

    B. Kuijper (Barbara); J.T. Tans; A. Beelen (Anita); F. Nollet (Frans); M. de Visser (Marianne)

    2009-01-01

    textabstractOBJECTIVE: To evaluate the effectiveness of treatment with collar or physiotherapy compared with a wait and see policy in recent onset cervical radiculopathy. DESIGN: Randomised controlled trial. SETTING: Neurology outpatient clinics in three Dutch hospitals. PARTICIPANTS: 205 patients

  19. Mechanical behaviour of a closed collar model for an 11.5 T dipole magnet

    International Nuclear Information System (INIS)

    Emden, W. van; Daum, C.; Geerinck, J.

    1992-03-01

    A 10 cm long model of an 11.5 T Nb 3 Sn accelerator dipole magnet, which will be built in the Netherlands, with a closed ring shaped collar has been constructed. Measurements of the collar deformation and the prestress at the poles have been made with a structural analysis using the Finite Element Method (FEM) of the code ANSYS. (author). 11 refs.; 18 figs.; 7 tabs

  20. The effect of nozzle collar on signle phase and boiling heat transfer by planar impinging jet

    International Nuclear Information System (INIS)

    Shin, Chang Hwan; Yim, Seong Hwan; Cho, Hyung Hee; Wu, Seong Je

    2005-01-01

    The water jet impingement cooling is one of the techniques to remove the heat from high heat flux equipment. Local heat transfer of the confined water impinging jet and the effect of nozzle collar to enhance the heat transfer are investigated in the free surface jet and submerged jet. Boiling is initiated from the farthest downstream and increase of the wall temperature is reduced with developing boiling, forming the flat temperature distributions. The reduction in the nozzle-to-surface distance for H/W≤1 causes significant increases and distribution changes of heat transfer. Developed boiling reduces the differences of heat transfer for various conditions. The nozzle collar is employed at the nozzle exit. The distances from heated surface to nozzle collar, H c are 0.25W, 0.5W and 1.0W. The liquid film thickness is reduced and the velocity of wall jet increases as decreased spacing of collar to heated surface. Heat transfer is enhanced for region from the stagnation to x/W∼8 in the free surface jet and to x/W∼5 in the submerged jet. For nucleate boiling region of further downstream, the heat transfer by the nozzle collar is decreased in submerged jet comparing with higher velocity condition. It is because the increased velocity by collar is de-accelerated downstream

  1. Influence of Austenitic Steel Collar Dimensions on Magnetic Field Harmonics in the LHC Main Dipole

    CERN Document Server

    Bellesia, B; Todesco, Ezio

    2005-01-01

    The influence of the geometry of the collars in the main LHC dipole on the magnetic field harmonics is analyzed. The study aims at finding if the collar geometry is the driving mechanism of field quality for some harmonics and if the two different collar suppliers give a special signature on the magnetic field. Data of more than 700 magnets of the LHC series dipoles are analyzed and discussed. The main result of the analysis is that the collar shape is the driving mechanism of the magnetic field harmonics only for b2 and a3 in one of the three Cold Mass Assemblers (Firm3), where only collars of the supplier S2 are used. Two independent observations support this fact: firstly, strong correlations between apertures of the same magnet as expected from the assembly procedure have been found. Secondly, the expected values based on the measured dimensions of the collars and on a magneto-static model agree with magnetic measurements both for the average and for the standard deviation.

  2. Horse-collar aurora: A frequent pattern of the aurora in quiet times

    International Nuclear Information System (INIS)

    Hones, E.W. Jr.; Craven, J.D.; Frank, L.A.; Evans, D.S.; Newell, P.T.

    1989-01-01

    Reported here are DE 1 auroral imager observations of an auroral configuration which is given the name ''horse-collar aurora.'' The horse-collar pattern comprises the total area of auroral emissions from a single hemisphere and derives its name from the shape of the emitting area. The pattern is found in images recorded during quiet geomagnetic conditions and is possibly related to the theta aurora, another quiet time configuration of the auroras. This initial report of the DE 1 observations illustrates the horse-collar aurora with a 2-hour images sequence that displays its basic features and shows an example of its evolution into a theta-like auroral pattern. The interplanetary magnetic field was northward during this image sequence and there is some evidence for IMF B/sub y/ influence of the temporal development of the horse-collar pattern. A preliminary statistical analysis found the horse-collar pattern appearing in one-third or more of image sequences recorded during quiet conditions; it did not appear during disturbed conditions. Further study is required to establish more fully the characteristics of the horse-collar aurora and to determine its implications concerning solar wind-magnetosphere coupling when the IMF B/sub z/ is northward. copyright American Geophysical Union 1989

  3. Cattle behaviour classification from collar, halter, and ear tag sensors

    Directory of Open Access Journals (Sweden)

    A. Rahman

    2018-03-01

    Full Text Available In this paper, we summarise the outcome of a set of experiments aimed at classifying cattle behaviour based on sensor data. Each animal carried sensors generating time series accelerometer data placed on a collar on the neck at the back of the head, on a halter positioned at the side of the head behind the mouth, or on the ear using a tag. The purpose of the study was to determine how sensor data from different placement can classify a range of typical cattle behaviours. Data were collected and animal behaviours (grazing, standing or ruminating were observed over a common time frame. Statistical features were computed from the sensor data and machine learning algorithms were trained to classify each behaviour. Classification accuracies were computed on separate independent test sets. The analysis based on behaviour classification experiments revealed that different sensor placement can achieve good classification accuracy if the feature space (representing motion patterns between the training and test animal is similar. The paper will discuss these analyses in detail and can act as a guide for future studies.

  4. Convenience in white-collar crime: A resource perspective

    Directory of Open Access Journals (Sweden)

    Petter Gottschalk

    2017-03-01

    Full Text Available White-collar offenders have access to resources that make financial crime convenient. In the rare case of crime suspicion, resources are available in terms of professional attorney work, control over internal investigations, and public relations support. Hiring private investigators at an early stage of potential crime disclosure enables the organization to control the investigation mandate and influence the investigation process and the investigation output. Getting an early start on reconstruction of the past in terms of a fraud examination makes it possible for the suspect and the organization to influence what facts are relevant and how facts might be assessed in terms of possible violations of the penal code. Convenience aspects of private investigations are discussed in this article in terms of five internal investigations, two in the United States (General Motors and Lehman Brothers and three in Norway (Telenor VimpelCom, DNB Bank, and Norwegian Football Association. The aim of this research is to contribute insights into convenience associated with internal private investigations.

  5. A Comperative Study on Perceptions and Reactions of Workers: A Resear ch on Blue and White Collar Workers

    Directory of Open Access Journals (Sweden)

    Fikret Ateş

    2014-06-01

    Full Text Available The purpose of this study is to examine perception of inequality and types of reaction of white and blue collar workers. The research was conducted over 120 white collar and 159 blue collar workers in an academic institution. It was determined with correlation analysis whether there is a relation between perception of inequality and reaction towards it for two groups. A significant and positive relation has been found between inequality perceptions and reaction towards inequality of blue collar workers. No significant relation has been found for white collar workers. Factor analysis was used to determine the dimensions of inequality perceptions andreactions towards inequality of blue and white collar workers. Results show that inequality perceptions and types of reactions towards inequality differ in terms of dimensions. Equity perceptions of blue collar workers are mostly based on comparisons with colleagues and nepotist behavior of their managers. White collar workers show sensitivity to the issues like salary, promotion and status. Blue collar workers prefer to report or to persuade their managers when they face with inequality. White collar workers decide to show their reactions by using more political methods.

  6. Ultracold neutrons

    International Nuclear Information System (INIS)

    Steenstrup, S.

    Briefly surveys recent developments in research work with ultracold neutrons (neutrons of very low velocity, up to 10 m/s at up to 10 -7 eV and 10 -3 K). Slow neutrons can be detected in an ionisation chamber filled with B 10 F 3 . Very slow neutrons can be used for investigations into the dipole moment of neutrons. Neutrons of large wave length have properties similar to those of light. The limit angle for total reflection is governed by the wave length and by the material. Total reflection can be used to filter ultracold neutrons out of the moderator material of a reactor. Total reflection can also be used to store ultracold neutrons but certain problems with storage have not yet been clarified. Slow neutrons can be made to lose speed in a neutron turbine, and come out as ultracold neutrons. A beam of ultracold neutrons could be used in a neutron microscope. (J.S.)

  7. Absolute calibration of TFTR helium proportional counters

    International Nuclear Information System (INIS)

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Loughlin, M.

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments

  8. CERN radiation protection (RP) calibration facilities

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Fabio

    2016-04-14

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelerators and at the CERN borders. A new state-of-the-art radiation protection calibration facility was designed, constructed and commissioned following the related ISO recommendations to replace the previous ageing (more than 30 years old) laboratory. In fact, the new laboratory aims also at the official accreditation according to the ISO standards in order to be able to release certified calibrations. Four radiation fields are provided: neutrons, photons and beta sources and an X-ray generator. Its construction did not only involve a pure civil engineering work; many radiation protection studies were performed to provide a facility that could answer the CERN calibration needs and fulfill all related safety requirements. Monte Carlo simulations have been confirmed to be a valuable tool for the optimization of the building design, the radiation protection aspects, e.g. shielding, and, as consequence, the overall cost. After the source and irradiator installation

  9. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-01-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane. Key points An increased shoe collar height effectively reduced ankle joint ROM in the sagittal plane in weight-bearing dorsiflexion maneuver. Shoe collar height did not affect sagittal plane ankle kinematics and had no effect on performance during realistic jumping. Shoe collar height can affect the ankle plantarflexion torque and peak power during the push-off phase in lay-up jump. PMID:29238255

  10. Job strain among blue-collar and white-collar employees as a determinant of total mortality: a 28-year population-based follow-up

    Science.gov (United States)

    Seitsamo, Jorma; von Bonsdorff, Monika E; Ilmarinen, Juhani; Nygård, Clas-Håkan; Rantanen, Taina

    2012-01-01

    Objectives To investigate the effect of job demand, job control and job strain on total mortality among white-collar and blue-collar employees working in the public sector. Design 28-year prospective population-based follow-up. Setting Several municipals in Finland. Participants 5731 public sector employees from the Finnish Longitudinal Study on Municipal Employees Study aged 44–58 years at baseline. Outcomes Total mortality from 1981 to 2009 among individuals with complete data on job strain in midlife, categorised according to job demand and job control: high job strain (high job demands and low job control), active job (high job demand and high job control), passive job (low job demand and low job control) and low job strain (low job demand and high job control). Results 1836 persons died during the follow-up. Low job control among men increased (age-adjusted HR 1.26, 95% CI 1.12 to 1.42) and high job demand among women decreased the risk for total mortality HR 0.82 (95% CI 0.71 to 0.95). Adjustment for occupational group, lifestyle and health factors attenuated the association for men. In the analyses stratified by occupational group, high job strain increased the risk of mortality among white-collar men (HR 1.52, 95% CI 1.09 to 2.13) and passive job among blue-collar men (HR 1.28, 95% CI 1.05 to 1.47) compared with men with low job strain. Adjustment for lifestyle and health factors attenuated the risks. Among white-collar women having an active job decreased the risk for mortality (HR 0.78, 95% CI 0.60 to 1.00). Conclusion The impact of job strain on mortality was different according to gender and occupational group among middle-aged public sector employees. PMID:22422919

  11. Hazard Prevention Regarding Occupational Accidents Involving Blue-Collar Foreign Workers: A Perspective of Taiwanese Manpower Agencies.

    Science.gov (United States)

    Chang, Huan-Cheng; Wang, Mei-Chin; Liao, Hung-Chang; Cheng, Shu-Fang; Wang, Ya-Huei

    2016-07-13

    Since 1989, blue-collar foreign workers have been permitted to work in Taiwanese industries. Most blue-collar foreign workers apply for jobs in Taiwan through blue-collar foreign workers' agencies. Because blue-collar foreign workers are not familiar with the language and culture in Taiwan, in occupational accident education and hazard prevention, the agencies play an important role in the coordination and translation between employees and blue-collar foreign workers. The purpose of this study is to establish the agencies' role in the occupational accidents education and hazard prevention for blue-collar foreign workers in Taiwan. This study uses a qualitative method-grounded theory-to collect, code, and analyze the data in order to understand the agencies' role in occupational accident education and hazard prevention for blue-collar foreign workers in Taiwan. The results show that the duty of agencies in occupational accident education and hazard prevention includes selecting appropriate blue-collar foreign workers, communicating between employees and blue-collar foreign workers, collecting occupational safety and health information, assisting in the training of occupational safety and health, and helping blue-collar foreign workers adapt to their lives in Taiwan. Finally, this study suggests seven important points and discusses the implementation process necessary to improve governmental policies. The government and employees should pay attention to the education/training of occupational safety and health for blue-collar foreign workers to eliminate unsafe behavior in order to protect the lives of blue-collar foreign workers.

  12. Hazard Prevention Regarding Occupational Accidents Involving Blue-Collar Foreign Workers: A Perspective of Taiwanese Manpower Agencies

    Directory of Open Access Journals (Sweden)

    Huan-Cheng Chang

    2016-07-01

    Full Text Available Since 1989, blue-collar foreign workers have been permitted to work in Taiwanese industries. Most blue-collar foreign workers apply for jobs in Taiwan through blue-collar foreign workers’ agencies. Because blue-collar foreign workers are not familiar with the language and culture in Taiwan, in occupational accident education and hazard prevention, the agencies play an important role in the coordination and translation between employees and blue-collar foreign workers. The purpose of this study is to establish the agencies’ role in the occupational accidents education and hazard prevention for blue-collar foreign workers in Taiwan. This study uses a qualitative method—grounded theory—to collect, code, and analyze the data in order to understand the agencies’ role in occupational accident education and hazard prevention for blue-collar foreign workers in Taiwan. The results show that the duty of agencies in occupational accident education and hazard prevention includes selecting appropriate blue-collar foreign workers, communicating between employees and blue-collar foreign workers, collecting occupational safety and health information, assisting in the training of occupational safety and health, and helping blue-collar foreign workers adapt to their lives in Taiwan. Finally, this study suggests seven important points and discusses the implementation process necessary to improve governmental policies. The government and employees should pay attention to the education/training of occupational safety and health for blue-collar foreign workers to eliminate unsafe behavior in order to protect the lives of blue-collar foreign workers.

  13. Core barrel motion calibration factor calculation

    International Nuclear Information System (INIS)

    Shahrokhi, F.; Robinson, J.C.

    1976-01-01

    Neutron transport theory calculations were performed to obtain a calibration factor for inferring core-barrel motion from spectral density data using excore ionization chambers in PWRs. The analysis of core-barrel movement was based on the postulate that the movement is a cantilevered type, with the preferred direction x-x'

  14. Neutron dosimetry intercomparison run for verification of the neutron fluence

    International Nuclear Information System (INIS)

    Penev, I.; Kinova, L.

    2001-01-01

    For the neutron fluence verification the intercomparison runs Balakovo and KORPUS have been carried out. The participation in the international intercomparison runs shows that in order to more precisely verify the calculated values of the neutron fluence more intercomparison exercises are necessary. Due to such exercises the results improved after calibration of Nb performed and are in a very good agreement with RIIAR results in spite of the different approaches in the determination of its activity

  15. Monitor for reactor neutron detector

    International Nuclear Information System (INIS)

    Shirakami, Hisayuki; Shibata, Masatoshi

    1992-01-01

    The device of the present invention judges as to whether a neutron detector is normal or not while considering the change of indication value depending on the power change of a reactor core. That is, the device of the present invention comprises a standard value setting device for setting the standard value for calibrating the neutron detector and an abnormality judging device for comparing the standard value with a measured value of the neutron detector and judging the abnormality when the difference is greater than a predetermined value. The measured value upon initialization of each of the neutron detectors is determined as a quasi-standard value. An average value of the difference between the measured value and the quasi-standard value of a plurality of effective neutron detectors at a same level for the height of the reactor core is multiplied to a power rate based on the reactor core power at a position where the neutron detector is disposed upon calibration. The value obtained by adding the multiplied value and the quasi-standard value is determined as a standard value. The abnormality judging device compares the standard value with the measured value of the neutron detector and, if the difference is greater than a predetermined value, the neutron detector is determined as abnormal. As a result, judgement can be conducted more accurately than conventional cases. (I.S.)

  16. Method and apparatus for determination of temperature, neutron absorption cross section and neutron moderating power

    Science.gov (United States)

    Vagelatos, Nicholas; Steinman, Donald K.; John, Joseph; Young, Jack C.

    1981-01-01

    A nuclear method and apparatus determines the temperature of a medium by injecting fast neutrons into the medium and detecting returning slow neutrons in three first energy ranges by producing three respective detection signals. The detection signals are combined to produce three derived indicia each systematically related to the population of slow neutrons returning from the medium in a respective one of three second energy ranges, specifically exclusively epithermal neutrons, exclusively substantially all thermal neutrons and exclusively a portion of the thermal neutron spectrum. The derived indicia are compared with calibration indicia similarly systematically related to the population of slow neutrons in the same three second energy ranges returning from similarly irradiated calibration media for which the relationships temperature, neutron absorption cross section and neutron moderating power to such calibration indicia are known. The comparison indicates the temperature at which the calibration indicia correspond to the derived indicia and consequently the temperature of the medium. The neutron absorption cross section and moderating power of the medium can be identified at the same time.

  17. NIF total neutron yield diagnostic

    International Nuclear Information System (INIS)

    Cooper, Gary W.; Ruiz, Carlos L.

    2001-01-01

    We have designed a total neutron yield diagnostic for the National Ignition Facility (NIF) which is based on the activation of In and Cu samples. The particular approach that we have chosen is one in which we calibrate the entire counting system and which we call the ''F factor'' method. In this method, In and/or Cu samples are exposed to known sources of DD and DT neutrons. The activated samples are then counted with an appropriate system: a high purity Ge detector for In and a NaI coincidence system for Cu. We can then calculate a calibration factor, which relates measured activity to total neutron yield. The advantage of this approach is that specific knowledge of such quantities as cross sections and detector efficiencies is not needed. Unless the actual scattering environment of the NIF can be mocked up in the calibration experiment, the F factor will have to be modified using the results of a numerical simulation of the NIF scattering environment. In this article, the calibration factor methodology will be discussed and experimental results for the calibration factors will be presented. Total NIF neutron yields of 10 9 --10 19 can be measured with this method assuming a 50 cm stand-off distance can be employed for the lower yields

  18. Dotted collar placed around carotid artery induces asymmetric neointimal lesion formation in rabbits without intravascular manipulations

    Directory of Open Access Journals (Sweden)

    Kivelä Antti

    2012-10-01

    Full Text Available Abstract Background Neointimal formation in atherosclerosis has been subject for intense research. However, good animal models mimicking asymmetrical lesion formation in human subjects have been difficult to establish. The aim of this study was to develop a model which would lead to the formation of eccentric lesions under macroscopically intact non-denuded endothelium. Methods We have developed a new collar model where we placed two cushions or dots inside the collar. Arterial lesions were characterized using histology and ultrasound methods. Results When this dotted collar was placed around carotid and femoral arteries it produced asymmetrical pressure on adventitia and a mild flow disturbance, and hence a change in shear stress. Our hypothesis was that this simple procedure would reproducibly produce asymmetrical lesions without any intraluminal manipulations. Intima/media ratio increased towards the distal end of the collar with the direction of blood flow under macroscopically intact endothelium. Macrophages preferentially accumulated in areas of the thickest neointima thus resembling early steps in human atherosclerotic plaque formation. Proliferating cells in these lesions and underlying media were scarce at eight weeks time point. Conclusion The improved dotted collar model produces asymmetrical human-like atherosclerotic lesions in rabbits. This model should be useful in studies regarding the pathogenesis and formation of eccentric atherosclerotic lesions.

  19. Occupational psychosocial hazards among the emerging U.S. green collar workforce

    Science.gov (United States)

    Fernandez, Cristina A.; Moore, Kevin; McClure, Laura A.; Caban-Martinez, Alberto J.; LeBlanc, William G.; Fleming, Lora E.; Cifuentes, Manuel; Lee, David J.

    2016-01-01

    Objective To compare occupational psychosocial hazards in green collar versus non-green collar workers. Methods Standard Occupational Classification codes were used to link the 2010 National Health Interview Survey to the 2010 Occupational Information Network Database. Multivariable logistic regressions were used to predict job insecurity, work-life imbalance, and workplace harassment in green versus non-green collar workers. Results Most participants were white, non-Hispanic, 25–64 years of age, and obtained greater than a high school education. The majority reported not being harassed at work, no work-life imbalance, and no job insecurity. Relative to non-green collar workers (n=12,217), green collar workers (n=2,588) were more likely to report job insecurity (OR=1.13; 95% CI=1.02–1.26) and work-life imbalance (1.19; 1.05–1.35), but less likely to experience workplace harassment (0.77; 0.62–0.95). Conclusions Continuous surveillance of occupational psychosocial hazards is recommended in this rapidly emerging workforce. PMID:28045790

  20. Energy response study of modified CR-39 neutron personnel dosimeter

    International Nuclear Information System (INIS)

    Sathian, Deepa; Bakshi, A.K.; Datta, D.; Nair, Sreejith S.; Sathian, V.; Mishra, Jitendra; Sen, Meghnath

    2018-01-01

    Personnel neutron dosimetry is an integral part of radiation protection. No single dosimeter provides the satisfactory energy response, sensitivity, angular dependence characteristics and accuracy necessary to meet the requirement of an ideal personnel neutron dosimeter. The response of a personnel neutron dosimeter is critically dependent upon the energy distribution of the neutron field. CR-39 personnel neutron dosimeters were typically calibrated in the standard neutron field of 252 Cf and 241 Am-Be in our laboratory, although actual neutron fields may vary from the calibration neutron spectrum. Recently the badge cassette of the personnel neutron dosimeter was changed due to frequent damage of the PVC badge used earlier. This paper discusses energy response of CR-39 solid state nuclear track detector loaded in this modified badge cassette as per latest ISO recommendation

  1. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1982-01-01

    The measurement of neutron exposures to personnel is an issue that has received increased attention in the last few years. It is important to consider key aspects of the whole dosimetry system when developing dose estimates. This begins with selection of proper dosimeters and survey instruments, and extends through the calibration methods. One must match the spectral response and sensitivity of the dosimeter to the spectral characteristics of the neutron fields. Threshold detectors that are insensitive to large fractions of neutrons in the lower energy portion of reactor spectra should be avoided. Use of two or more detectors with responses that complement each other will improve measurement quality. It is important to understand the spectral response of survey instruments, so that spectra which result in significant overresponse do not lead to overestimation of dose. Calibration sources that do not match operational field spectra can contribute to highly erroneous results. In those situations, in-field calibration techniques should be employed. Although some detection developments have been made in recent years, a lot can be done with existing technology until fully satisfactory, long term solutions are obtained

  2. Neutron energy response measurement of scintillation detectors

    International Nuclear Information System (INIS)

    Yang Hongqiong; Peng Taiping; Yang Jianlun; Tang Zhengyuan; Yang Gaozhao; Li Linbo; Hu Mengchun; Wang Zhentong; Zhang Jianhua; Li Zhongbao; Wang Lizong

    2004-01-01

    Neutron sensitivities of detectors composed of plastic scintillator ST401, ST1422, ST1423 and phyotomultiplier tube in primary energy range of fission neutron are calibrated by direct current. The energy response curve of the detectors is obtained in this experiment. The experimental result has been compared with the theoretical calculation and they are in agreement within measuring uncertainty. (authors)

  3. Postmortem findings in collared peccaries raised in captivity in northeastern Brazil

    Directory of Open Access Journals (Sweden)

    Jael S. Batista

    2014-11-01

    Full Text Available This study is a retrospective examination of diseases in collared peccaries that were diagnosed by the Veterinary Pathology Laboratory, Universidade Federal Rural do Semiárido. Necropsy and histological examination were performed from 2005 to 2010. Of the 50 necropsied collared peccaries, 24% died due to restraint and capture myopathy; 18% died from trauma; and the remainder was diagnosed with splenic hemangioma (6%, enterolithiasis (6%, gastritis (6%, gastric ulcer (4%, intestinal volvulus (4%, gastric volvulus (2%, mammary carcinoma (2%, polycystic kidney disease (2%, pyometra (2%, and suppurative bronchopneumonia (2%. Twelve animals remained undiagnosed, seven of which (14% were in advanced autolytic condition and five of which (10% had no gross or microscopic lesions that were compatible with disease. This paper describes illnesses that have not been reported in the collared peccary, focusing on their clinical and pathological aspects.

  4. Different spectra with the same neutron source

    International Nuclear Information System (INIS)

    Vega C, H. R.; Ortiz R, J. M.; Hernandez D, V. M.; Martinez B, M. R.; Hernandez A, B.; Ortiz H, A. A.; Mercado, G. A.

    2010-01-01

    Using as source term the spectrum of a 239 Pu-Be source several neutron spectra have been calculated using Monte Carlo methods. The source term was located in the centre of spherical moderators made of light water, heavy water and polyethylene of different diameters. Also a 239 Pu-Be source was used to measure its neutron spectrum, bare and moderated by water. The neutron spectra were measured at 100 cm with a Bonner spheres spectrometer. Monte Carlo calculations were used to calculate the neutron spectra of bare and water-moderated spectra that were compared with those measured with the spectrometer. Resulting spectra are similar to those found in power plants with PWR, BWR and Candu nuclear reactors. Beside the spectra the dosimetric features were determined. Using moderators and a single neutron source can be produced neutron spectra alike those found in workplaces, this neutron fields can be utilized to calibrate neutron dosimeters and area monitors. (Author)

  5. Neutron reflectometry

    International Nuclear Information System (INIS)

    Van Well, A.A.

    1999-01-01

    Neutron research where reflection, refraction, and interference play an essential role is generally referred to as 'neutron optics'. The neutron wavelength, the scattering length density and the magnetic properties of the material determine the critical angle for total reflection. The theoretical background of neutron reflection, experimental methods and the interpretation of reflection data are presented. (K.A.)

  6. Multidisk neutron velocity selectors

    International Nuclear Information System (INIS)

    Hammouda, B.

    1992-01-01

    Helical multidisk velocity selectors used for neutron scattering applications have been analyzed and tested experimentally. Design and performance considerations are discussed along with simple explanation of the basic concept. A simple progression is used for the inter-disk spacing in the 'Rosta' design. Ray tracing computer investigations are presented in order to assess the 'coverage' (how many absorbing layers are stacked along the path of 'wrong' wavelength neutrons) and the relative number of neutrons absorbed in each disk (and therefore the relative amount of gamma radiation emitted from each disk). We discuss whether a multidisk velocity selector can be operated in the 'reverse' configuration (i.e. the selector is turned by 180 0 around a vertical axis with the rotor spun in the reverse direction). Experimental tests and calibration of a multidisk selector are reported together with evidence that a multidisk selector can be operated in the 'reverse' configuration. (orig.)

  7. A neutron calorimeter as a fusion diagnostic

    International Nuclear Information System (INIS)

    Proctor, A.E.; Harker, Y.D.; Neischmidt, E.B.

    1986-01-01

    A calorimeter is described which is applicable as a fusion neutron diagnostic. The advantages of the device are discussed, including: low sensitivity to thermal neutrons, no heat loss to surroundings, large dynamic range, small mass resulting in fair time resolution, and small physical size. The heat generation is provided by neutron induced fissions in a foil of 238 U and a calorimeter is isothermal. The effects, advantages and disadvantages of other target materials are discussed. Also discussed are time resolution and calibration

  8. Portable system for periodical verification of area monitors for neutrons

    International Nuclear Information System (INIS)

    Souza, Luciane de R.; Leite, Sandro Passos; Lopes, Ricardo Tadeu; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da; Pereira, Walsan W.

    2009-01-01

    The Neutrons Laboratory develops a project viewing the construction of a portable test system for verification of functioning conditions of neutron area monitors. This device will allow to the users the verification of the calibration maintenance of his instruments at the use installations, avoiding the use of an inadequate equipment related to his answer to the neutron beam response

  9. A Correlation Study between Geometry of Collared Coils and Normal Quadrupole Multipole in the Main LHC Dipoles

    CERN Document Server

    Bertinelli, F; Berthollon-Vitte, S; Glaude, D; Vanenkov, I

    2006-01-01

    The quality control implemented at all LHC dipole assemblers includes precise mechanical measurements of the geometry of collared coils. A cross-analysis performed between mechanical and magnetic measurements data shows a correlation between collared coils outer dimensions and the normal quadrupole multipole (b2) for one dipole assembler. The profile geometry of the single collars - as determined from 3D measurements at the collar suppliers and CERN - could not account alone for the significant left – right aperture asymmetry observed. This triggered a deeper investigation on different elements of the geometry of single collars. The results of this work show that the relative positioning of the collaring holes, allowing a small bending deformation of collars under the effect of coil pre-stress, is an important effect that generates a b2 multipole at the limit of specification. The study has deepened the understanding of the factors affecting collared coil geometry and field quality. The precision of 3D m...

  10. Calibration of the TVO spent BWR reference fuel assembly

    International Nuclear Information System (INIS)

    Tarvainen, M.; Baecklin, A.; Haakanson, A.

    1992-02-01

    In 1989 the Support Programmes of Finland (FSP) and Sweden (SSP) initiated a joint task to cross calibrate the burnup of the IAEA spent BWR reference fuel assembly at the TVO AFR storage facility (TVO KPA-STORE) in Finland. The reference assembly, kept separately under the IAEA seal, is used for verification measurements of spent fuel by GBUV method (SG-NDA-38). The cross calibration was performed by establishing a calibration curve, 244 Cm neutron rate versus burnup, using passive neutron assay (PNA) measurements. The declared burnup of the reference assembly was compared with the burnup value deduced from the calibration curve. A calibration line was also established by using the GBUV method with the aid of high resolution gamma ray spectrometry (HRGS). Normalization between the two different facilities was performed using sealed neutron and gamma calibration sources. The results of the passive neutron assay show consistency, better than 1 %, between the declared mean burnup of the reference assembly and the burnup deduced from the calibration curve. The corresponding consistency is within +-2 % for the HRGS measurements

  11. Neutron radiography with ultracold neutrons

    International Nuclear Information System (INIS)

    Bates, J.C.

    1981-01-01

    The neutron transmission factor of very thin films may be low if the neutron energy is comparable to the pseudo-potential of the film material. Surprisingly, perhaps, it is relatively easy to obtain neutrons with such low energies in sufficient numbers to produce neutron radiographs. (orig.)

  12. Neutron Skins and Neutron Stars

    OpenAIRE

    Piekarewicz, J.

    2013-01-01

    The neutron-skin thickness of heavy nuclei provides a fundamental link to the equation of state of neutron-rich matter, and hence to the properties of neutron stars. The Lead Radius Experiment ("PREX") at Jefferson Laboratory has recently provided the first model-independence evidence on the existence of a neutron-rich skin in 208Pb. In this contribution we examine how the increased accuracy in the determination of neutron skins expected from the commissioning of intense polarized electron be...

  13. Two-channel neutron boron meter

    International Nuclear Information System (INIS)

    Chen Yongqing; Yin Guowei; Chai Songshan; Deng Zhaoping; Zhou Bin

    1993-09-01

    The two-channel neutron boron meter is a continuous on-line measuring device to measure boron concentration of primary cooling liquid of reactors. The neutron-leakage-compensation method is taken in the measuring mechanism. In the primary measuring configuration, the mini-boron-water annulus and two-channel and central calibration loop are adopted. The calibration ring and constant-temperature of boron-water can be remotely controlled by secondary instruments. With the microcomputer data processing system the boron concentration is automatically measured and calibrated in on-line mode. The meter has many advantages such as high accuracy, fast response, multi-applications, high reliability and convenience

  14. Neutron moisture measurement in materials

    International Nuclear Information System (INIS)

    Thony, J.L.

    1985-01-01

    This method is generally used for soil moisture determination but also for moisture in building materials. After a review of neutron interaction with matter (elastic and inelastic scattering, radiative capture and absorption with emission of charged particles) and of the equipment (source, detector and counting), gravimetric and chemical calibration are described and accuracy of measurement is discussed. 5 refs [fr

  15. The effect on patency of type, shape and volume of a vein collar used at the distal anastomis of PTFE-bypass to arteries below-knee

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    The aim of this paper was to study the effect on patency rate of different types of vein collar (Miller's original or St Mary's boot), different length/height shapes of vein collar, and different vein collar volumes at the distal anastomosis of PTFE-bypass grafts to below-knee arteries in patients...

  16. Portable neutron moisture gage for the moisture determination of structure parts

    International Nuclear Information System (INIS)

    Harnisch, M.

    1985-01-01

    For determining the moisture of structure parts during building or before repairing a portable neutron moisture gage consisting of a neutron probe and pulse analyzer has been developed. The measuring process, calibration, and prerequisites of application are briefly discussed

  17. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Sasao, M.; Krasilnikov, A.V.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Jarvis, O.N.; Iguchi, T.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be well measured by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include: radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors, neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The neutron flux monitors need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented. (author)

  18. Neutron Dosimetry

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2001-01-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding

  19. Neutron Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Vanhavere, F

    2001-04-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding.

  20. Exploring New York State Policy Expectations Pertaining to Energy Efficiency and Green Collar Workforce

    Science.gov (United States)

    Pauli, Felix Asher

    2012-01-01

    The Green Jobs Green New York (GJGNY) Act of 2009 was designed to reduce energy consumption by creating green collar workforce and providing energy efficiency audits to the public. The problem addressed in this study is the discrepancy between the expectations of Green Jobs Green New York Act of 2009 and the implementation of this policy. This…

  1. Blue-Collar Affluence in a Remote Mining Town: Challenging the Modernist Myth of Education

    Science.gov (United States)

    Forsey, Martin

    2015-01-01

    Based on research in Karratha, a remote resource town in Western Australia, this paper explores the ways in which blue-collar affluence disturbs the meritocratic mythology of formal education. In the opening decade of the twenty-first century Karratha was one of Australia's most affluent towns, yet its adult population was characterised by a level…

  2. Plectosphaerella species associated with root and collar rots of horticultural crops in southern Italy

    NARCIS (Netherlands)

    Carlucci, A.; Raimondo, M.L.; Santos, J.; Phillips, A.J.L.

    2012-01-01

    Plectosphaerella cucumerina, most frequently encountered in its Plectosporium state, is well known as a pathogen of several plant species causing fruit, root and collar rot, and collapse. It is considered to pose a serious threat to melon (Cucumis melo) production in Italy. In the present study, an

  3. The Association between Training and Organizational Commitment among White-Collar Workers in Malaysia.

    Science.gov (United States)

    Ahmad, Kamarul Zaman; Bakar, Raida Abu

    2003-01-01

    Responses from 204 of 300 Malaysian white-collar workers were analyzed for the association between training variables (availability of support, benefits, motivation, environment) and four types of organizational commitment. All training variables were significantly correlated with affective, normative, and overall commitment. Availability of…

  4. Why "Working Smarter" Isn't Working: White-Collar Productivity Improvement.

    Science.gov (United States)

    Shaw, Edward

    2001-01-01

    Discusses the productivity and work days of white collar workers. Topics include productivity improvement; task analysis; the amount of time spent reading, and how to reduce it by improving writing skills; time spent in meetings; empowered time management; and sustaining a climate for change. (LRW)

  5. Socializing Messages in Blue-Collar Families: Communicative Pathways to Social Mobility and Reproduction

    Science.gov (United States)

    Lucas, Kristen

    2011-01-01

    This study explicitly links processes of anticipatory socialization to social mobility and reproduction. An examination of the socializing messages exchanged between blue-collar parents (n = 41) and their children (n = 25) demonstrate that family-based messages about work and career seldom occur in straightforward, unambiguous ways. Instead,…

  6. Mind over matter: exploring job stress among female blue-collar workers.

    Science.gov (United States)

    Griffin-Blake, C Shannon; Tucker, Pattie J; Liburd, Leandris

    2006-12-01

    Although overall health has been defined holistically as the integration of a person's optimal mental, physical, social, intellectual, and spiritual well-being, a mental health focus remains on the fringe of many public health efforts. This report describes recent efforts by the Centers for Disease Control and Prevention (CDC) to explore job stress among female blue-collar workers. Using a more holistic approach to understand its impact on blue-collar women's overall health, health-related quality of life (HRQOL) was used to assess optimal human performance. Attempting to encapsulate how overall health affects one's ability to participate and fulfill daily personal/professional tasks, HRQOL yields a broader understanding of the interaction between psychological well-being (mind) and physical functioning (matter). Embedding CDC HRQOL-4 measures into a questionnaire used as part of a larger mixed methods project, blue-collar women responded to questions about their health, including both mental and physical. For these female workers, mental health appeared to be of greater consequence, which could be interpreted as mind being more significant than matter. This paper highlights the findings related to HRQOL issues experienced by these female blue-collar workers and summarizes recommendations for effective individual and organizational approaches to address job stress.

  7. "Blue-Collar Blues" uurib töösuhteid uutes oludes / Janar Ala

    Index Scriptorium Estoniae

    Ala, Janar, 1979-

    2009-01-01

    Tööproblemaatikat käsitlev näitus "Blue-Collar Blues" Tallinna Kunstihoones ja Tallinna Kunstihoone galeriis 31. jaanuarini 2010, kuraator Anders Härm. Lähemalt belgia-mehhiko kunstniku Francis Alys'e videost, austria kunstniku Oliver Ressleri ning venetsueela-saksa politoloogi Dario Azzelini videost "Viis tehast. Tööliste kontroll Venezuelas"

  8. Understanding workplace boredom among white collar employees : temporary reactions and individual differences

    NARCIS (Netherlands)

    Heijden, van der G.A.H.; Schepers, J.J.L.; Nijssen, E.J.

    2012-01-01

    The purpose of this study is to investigate white collar employees' temporary relief strategies to workplace boredom. Building on self-regulation theory we define two responses: engaging in distraction and work indifference. We also investigate whether some individuals are more likely to engage in

  9. Birds be safe: Can a novel cat collar reduce avian mortality by domestic cats (Felis catus?

    Directory of Open Access Journals (Sweden)

    S.K. Willson

    2015-01-01

    Full Text Available The domestic cat (Felis catus has been described as the largest anthropogenic threat to songbird populations in North America. We examined the effectiveness of a novel cat collar in reducing avian and small mammal mortality by cats. The 2-inch wide Birdsbesafe® collar cover (CC is worn over a nylon quick-release collar, and the bright colors and patterns of the CC are hypothesized to warn birds of approaching cats. We conducted two seasonal trials, each lasting 12 weeks, in autumn 2013 (n=54 cats and spring 2014 (n=19 cats. Cats were randomly assigned to two groups, and CCs with interior collars were removed or put on every two weeks, to control for weather fluctuations and seasonal change. Cats wearing Birdsbesafe® CCs killed 19 times fewer birds than uncollared cats in the spring trial, and 3.4 times fewer birds in the fall. Birdsbesafe® CCs were extremely effective at reducing predation on birds. Small mammal data were less clear, but did decrease predation by half in the fall. The Birdsbesafe® CC is a highly effective device for decreasing bird predation, especially in the spring season. We suggest that the CCs be used as a conservation tool for owned as well as feral cats.

  10. Original Paper Effects of oxen yoke and donkey collar on traction ...

    African Journals Online (AJOL)

    The realization of mechanized zaï with draft animal encounters the weakness of hitch traction capabilities. To overcome this issue, a study was conducted in three villages in the northern Burkina Faso with the aim at evaluating the effect of improved yoke and improved collar respectively with oxen and donkey harnessing on ...

  11. The development and validation of a job crafting measure for use with blue-collar workers

    DEFF Research Database (Denmark)

    Nielsen, Karina; Abildgaard, Johan Simonsen

    2012-01-01

    Abstract Job crafting describes a set of proactive behaviours in which employees may engage to shape their work in order to minimize hindering job demands and maximize resources and challenging demands. Such behaviours may be particularly important among blue-collar workers whose jobs are charact......Abstract Job crafting describes a set of proactive behaviours in which employees may engage to shape their work in order to minimize hindering job demands and maximize resources and challenging demands. Such behaviours may be particularly important among blue-collar workers whose jobs...... are characterized by poor working conditions and low well-being. We present the development and adaptation of a job crafting measure that may be used among blue-collar workers, based on an existing scale by Tims, Bakker, and Derks (2012) that was not specifically developed for blue-collar workers. We test......, increasing social job resources, increasing quantitative demands and decreasing hindering job demands. These can be reliably measured with 15 items. The measure shows acceptable discriminant and criterion validity, and test-retest reliability. The findings extend the application of the original questionnaire...

  12. An Examination of Blue- versus White-Collar Workers' Conceptualizations of Job Satisfaction Facets

    Science.gov (United States)

    Hu, Xiaoxiao; Kaplan, Seth; Dalal, Reeshad S.

    2010-01-01

    This study examined the degree to which blue- versus white-collar workers differentially conceptualize various job facets, namely the work itself, co-workers, supervisors, and pay. To examine these potential differences, we conducted a series of analyses on job satisfaction ratings from two samples of university workers. Consistent with the study…

  13. How Blue-Collar Workers on 4-Day Workweeks Use Their Time

    Science.gov (United States)

    Maklan, David Mark

    1977-01-01

    Describes a study of the behavior of male blue-collar workers on 4-day workweeks, revealing that they participate in the same activities as similar 5-day workers. Discussion focuses on the impact of the 4-day week on use of time and on the individual's satisfaction with leisure activities. (TA)

  14. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    Science.gov (United States)

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  15. Job Attitudes of Black and White Workers: Male Blue-Collar Workers in Six Companies

    Science.gov (United States)

    Katzell, Raymond A.; And Others

    1974-01-01

    A 74-item attitude questionnaire was administered in six companies to 101 black and 87 white male blue-collar employees holding similar jobs in the same company. Differences between the two ethnic groups were not marked, both in terms of job satisfaction and in other respects. (Author)

  16. Causes and consequences of timing errors associated with global positioning system collar accelerometer activity monitors

    Science.gov (United States)

    Adam J. Gaylord; Dana M. Sanchez

    2014-01-01

    Direct behavioral observations of multiple free-ranging animals over long periods of time and large geographic areas is prohibitively difficult. However, recent improvements in technology, such as Global Positioning System (GPS) collars equipped with motion-sensitive activity monitors, create the potential to remotely monitor animal behavior. Accelerometer-equipped...

  17. Job demands and health complaints in white and blue collar workers

    NARCIS (Netherlands)

    Schreuder, K. J.; Roelen, C. A. M.; Koopmans, P. C.; Groothoff, J. W.

    2008-01-01

    Background: General health in the working population is thought to depend on working conditions. Objective: This survey studied job demands and health complaints in working white and blue collar employees. We expect physical and psychological job demands to be differentially distributed among white

  18. Biometric monitor with electronics disposed on or in a neck collar

    NARCIS (Netherlands)

    2012-01-01

    A highly portable biometric monitor is disclosed. At least one remote sensor member (12, 12') includes one or more biometric sensors (20, 22, 24, 25) configured for operative coupling with a patient. A neck collar (14, 114, 214, 314, 414) includes electronics (36, 40, 42, 44, 46, 48) for operating

  19. Analysis of the collar-whisker structure of temperate lactococcal bacteriophage TP901-1

    DEFF Research Database (Denmark)

    Vegge, Christina Skovgaard; Neve, Horst; Brøndsted, Lone

    2006-01-01

    Proteins homologous to the protein NPS (neck passage structure) are widespread among lactococcal phages. We investigated the hypothesis that NPS is involved in the infection of phage TP901-1 by analysis of an NPS mutant. NPS was determined to form a collar-whisker complex but was shown to be none...

  20. Cervical collar or physiotherapy versus wait and see policy for recent onset cervical radiculopathy: randomised trial

    NARCIS (Netherlands)

    Kuijper, Barbara; Tans, Jos Th J.; Beelen, Anita; Nollet, Frans; de Visser, Marianne

    2009-01-01

    Objective To evaluate the effectiveness of treatment with collar or physiotherapy compared with a wait and see policy in recent onset cervical radiculopathy. Design Randomised controlled trial. Setting Neurology outpatient clinics in three Dutch hospitals. Participants 205 patients with symptoms and

  1. Discussions in symposium 'neutron dosimetry in neutron fields - from detection techniques to medical applications'

    International Nuclear Information System (INIS)

    Tanimura, Y.; Sato, T.; Kumada, H.; Terunuma, T.; Sakae, T.; Harano, H.; Matsumoto, T.; Suzuki, T.; Matsufuji, N.

    2008-01-01

    Recently the traceability system (JCSS) of neutron standard based on the Japanese law 'Measurement Act' has been instituted. In addition, importance of the neutron dose evaluation has been increasing in not only the neutron capture medical treatment but also the proton or heavy particle therapy. Against such a background, a symposium 'Neutron dosimetry in neutron fields - From detection techniques to medical applications-' was held on March 29, 2008 and recent topics on the measuring instruments and their calibration, the traceability system, the simulation technique and the medical applications were introduced. This article summarizes the key points in the discussion at the symposium. (author)

  2. Assessing neutron generator output using neutron activation of silicon

    International Nuclear Information System (INIS)

    Kehayias, Pauli M.; Kehayias, Joseph J.

    2007-01-01

    D-T neutron generators are used for elemental composition analysis and medical applications. Often composition is determined by examining elemental ratios in which the knowledge of the neutron flux is unnecessary. However, the absolute value of the neutron flux is required when the generator is used for neutron activation analysis, to study radiation damage to materials, to monitor the operation of the generator, and to measure radiation exposure. We describe a method for absolute neutron output and flux measurements of low output D-T neutron generators using delayed activation of silicon. We irradiated a series of silicon oxide samples with 14.1 MeV neutrons and counted the resulting gamma rays of the 28 Al nucleus with an efficiency-calibrated detector. To minimize the photon self-absorption effects within the samples, we used a zero-thickness extrapolation technique by repeating the measurement with samples of different thicknesses. The neutron flux measured 26 cm away from the tritium target of a Thermo Electron A-325 D-T generator (Thermo Electron Corporation, Colorado Springs, CO) was 6.2 x 10 3 n/s/cm 2 ± 5%, which is consistent with the manufacturer's specifications

  3. Assessing neutron generator output using neutron activation of silicon

    Energy Technology Data Exchange (ETDEWEB)

    Kehayias, Pauli M. [Body Composition Laboratory, Jean Mayer United States Department of Agriculture Human Nutrition Research Center on Aging, Tufts University, Boston, MA 02111 (United States); Kehayias, Joseph J. [Body Composition Laboratory, Jean Mayer United States Department of Agriculture Human Nutrition Research Center on Aging, Tufts University, Boston, MA 02111 (United States)]. E-mail: joseph.kehayias@tufts.edu

    2007-08-15

    D-T neutron generators are used for elemental composition analysis and medical applications. Often composition is determined by examining elemental ratios in which the knowledge of the neutron flux is unnecessary. However, the absolute value of the neutron flux is required when the generator is used for neutron activation analysis, to study radiation damage to materials, to monitor the operation of the generator, and to measure radiation exposure. We describe a method for absolute neutron output and flux measurements of low output D-T neutron generators using delayed activation of silicon. We irradiated a series of silicon oxide samples with 14.1 MeV neutrons and counted the resulting gamma rays of the {sup 28}Al nucleus with an efficiency-calibrated detector. To minimize the photon self-absorption effects within the samples, we used a zero-thickness extrapolation technique by repeating the measurement with samples of different thicknesses. The neutron flux measured 26 cm away from the tritium target of a Thermo Electron A-325 D-T generator (Thermo Electron Corporation, Colorado Springs, CO) was 6.2 x 10{sup 3} n/s/cm{sup 2} {+-} 5%, which is consistent with the manufacturer's specifications.

  4. Measurement of TLD Albedo response on various calibration phantoms

    International Nuclear Information System (INIS)

    Momose, T.; Tsujimura, N.; Shinohara, K.; Ishiguro, H.; Nakamura, T.

    1996-01-01

    The International Commission on Radiation Units and Measurements (ICRU) has recommended that individual dosemeter should be calibrated on a suitable phantom and has pointed out that the calibration factor of a neutron dosemeter is strongly influenced by the the exact size and shape of the body and the phantom to which the dosemeter is attached. As the principle of an albedo type thermoluminescent personal dosemeter (albedo TLD) is essentially based on a detection of scattered and moderated neutron from a human body, the sensitivity of albedo TLD is strongly influenced by the incident neutron energy and the calibration phantom. (1) Therefore for albedo type thermoluminescent personal dosemeter (albedo TLD), the information of neutron albedo response on the calibration phantom is important for appropriate dose estimation. In order to investigate the effect of phantom type on the reading of the albedo TLD, measurement of the TLD energy response and angular response on some typical calibration phantoms was performed using dynamitron accelerator and 252 Cf neutron source. (author)

  5. Design and testing of a GPS/GSM collar prototype to combat cattle rustling

    Directory of Open Access Journals (Sweden)

    Francesco M. Tangorra

    2013-10-01

    Full Text Available Rustling is an age-old practice that was widespread in Italy until the first half of the 20th century. Today, incidents of cattle rustling are again being reported. However, the problem is not only found in Italy. It is also becoming a plague for ranchers in the US and is still rampant in East Africa. In Italy, the cattle rustling phenomena have usually been limited through the direct control of the herdsmen. Global positioning system (GPS and geographic information system (GIS combined technologies are increasingly applied for tracking and monitoring livestock with greater spatial and temporal resolution. However, so far, no case studies of the use of GPS technology to combat cattle rustling have been reported in the literature. The aim of this research was to develop a GPS/GSM (global system for mobile communication collar, using commercial hardware and implementing a specific software [ARVAshepherd 1.0; ARVAtec Srl, Rescaldina (MI, Italy] to track animals’ movements outside their grazing area and to signal when animals are straying outside virtual perimeters. A phase I study was conducted from January to June 2011 to build the GPS/GSM collar and to assess its performances in terms of GPS accuracy and precision, while a phase II study was conducted in July 2011 to test the GPS collar under real-life operating conditions. The static GPS positioning error achieved a circular error probable (50% and horizontal 95% accuracy of 1.462 m and 4.501 m, respectively. This is comparable with values obtained by other authors in static tests of a commercial GPS collar for grazing studies. In field tests, the system was able to identify the incorrect position of the cattle and the warning messages were sent promptly to the farmer, continuing until the animals had been repositioned inside the fence, thus highlighting the potential of the GPS/GSM collar as an anti-theft system.

  6. Ergonomic assessment of enhanced protection under body armour combat shirt neck collars.

    Science.gov (United States)

    Breeze, John; Granger, C J; Pearkes, T D; Clasper, J C

    2014-03-01

    Combat neck injury due to explosively propelled fragments is a significant cause of mortality and long-term morbidity in UK soldiers deployed on current operations. Reinforcing the collar of the existing under body armour combat shirt (UBACS) has been suggested as a potential method for reducing the incidence of combat neck injury. 20 soldiers serving in Afghanistan objectively compared three designs of enhanced protection UBACS (EP-UBACS) using 10 representative military tasks against a baseline of a standard UBACS. Each EP-UBACS design was trialled using three constituent materials: two layers of para-aramid felt, one layer of ultra high molecule weight polyethylene (UHMWPE) felt or two layers of a silk fabric. Subjective assessment of these nine configurations in terms of comfort, heat dissipation and overall acceptability were compared with the standard UBACS using a χ² test. All military tasks could be performed with all nine configurations of EP-UBACS. Although silk was the most comfortable material, it was not functionally practical in any of the three designs. Crossover collars incorporating UHMWPE or para-aramid were the only two of the nine configurations to demonstrate similar user acceptability to a standard UBACS. The EP-UBACS has the potential to provide neck protection without reducing performance incorporating materials analogous to either of the felts assessed in this study. The collar should provide stand-off from the skin to improve heat dissipation and comfort, which can be maximised by changing the current UBACS collar shape to one that crosses over at the front. Should a zip be desired, it should be moved to one side of the midline to reduce rubbing on the chin and be covered with ballistic protective material. Additional semi-circles of silk beneath the collar at the front and back would improve protection without affecting comfort.

  7. Neutron generator instrumentation at the Department 2350 Neutron Generator Test Facility

    International Nuclear Information System (INIS)

    Bryant, T.C.; Mowrer, G.R.

    1979-06-01

    The computer and waveform digitizing capability at the test facility has allowed several changes in the techniques used to test neutron generators. These changes include methods used to calibrate the instrumentation and changes in the operation of the test facility. These changes have increased the efficiency of the test facility as well as increasing both timing and amplitude accuracy of neutron generator waveforms

  8. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  9. Neutron moisture gaging of agricultural soil

    International Nuclear Information System (INIS)

    Pospisil, S.; Janout, Z.; Kovacik, M.

    1987-01-01

    The design is described of a neutron moisture gage which consists of a measuring probe, neutron detector, small electronic recording device and a 241 Am-Be radionuclide source. The neutron detector consists of a surface barrier semiconductor silicon detector and a conversion layer of lithium fluoride. The detection of triton which is the reaction product of lithium with neutrons by the silicon detector is manifested as a voltage pulse. The detector has low sensitivity for fast neutrons and for gamma radiation and is suitable for determining moisture values in large volume samples. Verification and calibration measurements were carried out of chernozem, brown soil and podzolic soils in four series. The results are tabulated. Errors of measurement range between 0.8 to 1.0%. The precision of measurement could be improved by the calibration of the device for any type of soil. (E.S.). 4 tabs., 6 refs., 5 figs

  10. Calibration of RB reactor power

    International Nuclear Information System (INIS)

    Sotic, O.; Markovic, H.; Ninkovic, M.; Strugar, P.; Dimitrijevic, Z.; Takac, S.; Stefanovic, D.; Kocic, A.; Vranic, S.

    1976-09-01

    The first and only calibration of RB reactor power was done in 1962, and the obtained calibration ratio was used irrespective of the lattice pitch and core configuration. Since the RB reactor is being prepared for operation at higher power levels it was indispensable to reexamine the calibration ratio, estimate its dependence on the lattice pitch, critical level of heavy water and thickness of the side reflector. It was necessary to verify the reliability of control and dosimetry instruments, and establish neutron and gamma dose dependence on reactor power. Two series of experiments were done in June 1976. First series was devoted to tests of control and dosimetry instrumentation and measurements of radiation in the RB reactor building dependent on reactor power. Second series covered measurement of thermal and epithermal neuron fluxes in the reactor core and calculation of reactor power. Four different reactor cores were chosen for these experiments. Reactor pitches were 8, 8√2, and 16 cm with 40, 52 and 82 fuel channels containing 2% enriched fuel. Obtained results and analysis of these results are presented in this document with conclusions related to reactor safe operation

  11. Unskilled blue collar workers: Bourgeois and/or authoritarian? Results from a small scale survey in Belgium

    Directory of Open Access Journals (Sweden)

    Hans De Witte

    2007-04-01

    adopted the attitudes (and life style of white collar workers, from whom they can no longer be distinguished. Lipset’s hypothesis of the ‘authoritarianism of the working class’, on the other hand, states that blue collar workers more strongly endorse a conservative attitude on socio-cultural matters and a progressive stand concerning socio-economic issues. Both hypotheses are tested using data from a small scale survey (N = 135 among unskilled blue collar workers and lower- and mid-level white collar workers from different large companies in the region of Leuven, Belgium. The results indicate that the interviewed unskilled blue collar workers still hold a set of attitudes that distinguishes them from the interviewed white collar workers. So, the ‘embourgeoisement’ thesis was refuted. Instead, the unskilled blue collar workers were more conservative on a socio-cultural level, and more progressive concerning socio-economic issues. These results are in line with Lipset’s ‘authoritarianism of the working class’ hypothesis.

  12. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  13. The neutron

    International Nuclear Information System (INIS)

    Kredov, B.M.

    1979-01-01

    The history of the neutron is displayed on the basis of contributions by scientists who produced outstanding results in neutron research (part 1), of summarizing discoveries and theories which led to the discovery of the neutron and the resulting development of nuclear physics (part 2), and of fundamental papers written by Rutherford, Chadwick, Iwanenko, and others (appendix). Of interest to physicists, historians, and students

  14. Neutron techniques

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1986-01-01

    The way in which neutrons interact with matter such as slowing-down, diffusion, neutron absorption and moderation are described. The use of neutron techniques in industry, in moisture gages, level and interface measurements, the detection of blockages, boron analysis in ore feedstock and industrial radiography are discussed. (author)

  15. Personal neutron dosimetry at a research reactor facility

    International Nuclear Information System (INIS)

    Kamenopoulou, V.; Carinou, E.; Stamatelatos, I.E.

    2001-01-01

    Individual neutron monitoring presents several difficulties due to the differences in energy response of the dosemeters. In the present study, an individual dosemeter (TLD) calibration approach is attempted for the personnel of a research reactor facility. The neutron energy response function of the dosemeter was derived using the MCNP code. The results were verified by measurements to three different neutron spectra and were found to be in good agreement. Three different calibration curves were defined for thermal, intermediate and fast neutrons. At the different working positions around the reactor, neutron spectra were defined using the Monte Carlo technique and ambient dose rate measurements were performed. An estimation of the neutrons energy is provided by the ratio of the different TLD pellets of each dosemeter in combination with the information concerning the worker's position; then the dose equivalent is deduced according to the appropriate calibration curve. (author)

  16. Calibrations of a tritium extraction facility

    International Nuclear Information System (INIS)

    Bretscher, M.M.; Oliver, B.M.; Farrar, H. IV.

    1983-01-01

    A tritium extraction facility has been built for the purpose of measuring the absolute tritium concentration in neutron-irradiated lithium metal samples. Two independent calibration procedures have been used to determine what fraction, if any, of tritium is lost during the extraction process. The first procedure compares independently measured 4 He and 3 H concentrations from the 6 Li(n,α)T reaction. The second procedure compared measured 6 Li(n,α)T/ 197 Au (n,γ) 198 Au thermal neutron reaction rate ratios with those obtained from Monte Carlo calculations using well-known cross sections. Both calibration methods show that within experimental errors (approx. 1.5%) no tritium is lost during the extraction process

  17. Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments

    International Nuclear Information System (INIS)

    Lee, K.W.; Sheu, R.J.

    2015-01-01

    High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with 252 Cf neutron sources and are used in various workplace. A workplace-specific correction factor is suggested. In this study, the effect of the neutron spectrum on the accuracy of dose measurements was investigated. A set of neutron spectra representing various neutron environments was selected to study the dose responses of a series of Bonner spheres, including standard and extended-range spheres. By comparing 252 Cf-calibrated dose responses with reference values based on fluence-to-dose conversion coefficients, this paper presents recommendations for neutron field characterisation and appropriate correction factors for responses of conventional neutron dosemeters used in environments with high-energy neutrons. The correction depends on the estimated percentage of high-energy neutrons in the spectrum or the ratio between the measured responses of two Bonner spheres (the 4P6-8 extended-range sphere versus the 6'' standard sphere). (authors)

  18. Neutron yield measurements on a TMX endplug

    International Nuclear Information System (INIS)

    Slaughter, D.R.

    1980-01-01

    Neutron yield measurements were made on the east endplug of TMX using a calibrated recoil proton counter. The detector consists of a liquid scintillator (NE 213) with a pulse shape discrimination property that allows for identifying photon and neutron interactions. An energy threshold is established to suppress the response to scattered neutrons with energies lower than 1 to 2 MeV. Results indicate there are typical neutron yields of 2 to 3 x 10 11 n/s during a 25-ms discharge with 200 A of 20-keV neutral beam injection into the endplug

  19. Reference neutron radiations. Part 1: Characteristics and methods of production

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 1. of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV, for calibrating neutron-measuring devices used for radiation protection purposes and for determining their response as a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1x10 9 m 2 s-1 , corresponding, at a neutron energy of 1 MeV, to dose-equivalent rates of up to 100 mSv h -1 . This part of ISO 8529 is concerned only with the methods of producing and characterizing the neutron reference radiations. The procedures for applying these radiations for calibrations are described in ISO 8529-2 and ISO 8529-3. The reference radiations specified are the following: neutrons from radionuclide sources, including neutrons from sources in a moderator; neutrons produced by nuclear reactions with charged particles from accelerators; neutrons from reactors. In view of the methods of production and use of them, these reference radiations are divided, for the purposes of this part of ISO 8529, into the following two separate sections. In clause 4, radionuclide neutron sources with wide spectra are specified for the calibration of neutron measuring devices. These sources should be used by laboratories engaged in the routine calibration of neutron-measuring devices, the particular design of which has already been type tested. In clause 5, accelerator-produced monoenergetic neutrons and reactor-produced neutrons with wide or quasi monoenergetic spectra are specified for determining the response of neutron-measuring devices

  20. Neutron emissivity profile camera diagnostics considering present and future tokamaks

    International Nuclear Information System (INIS)

    Forsberg, S.

    2001-12-01

    This thesis describes the neutron profile camera situated at JET. The profile camera is one of the most important neutron emission diagnostic devices operating at JET. It gives useful information of the total neutron yield rate but also about the neutron emissivity distribution. Data analysis was performed in order to compare three different calibration methods. The data was collected from the deuterium campaign, C4, in the beginning of 2001. The thesis also includes a section about the implication of a neutron profile camera for ITER, where the issue regarding interface difficulties is in focus. The ITER JCT (Joint Central Team) proposal of a neutron camera for ITER is studied in some detail

  1. Neutron emissivity profile camera diagnostics considering present and future tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Forsberg, S. [EURATOM-VR Association, Uppsala (Sweden)

    2001-12-01

    This thesis describes the neutron profile camera situated at JET. The profile camera is one of the most important neutron emission diagnostic devices operating at JET. It gives useful information of the total neutron yield rate but also about the neutron emissivity distribution. Data analysis was performed in order to compare three different calibration methods. The data was collected from the deuterium campaign, C4, in the beginning of 2001. The thesis also includes a section about the implication of a neutron profile camera for ITER, where the issue regarding interface difficulties is in focus. The ITER JCT (Joint Central Team) proposal of a neutron camera for ITER is studied in some detail.

  2. Mechanics of log calibration

    International Nuclear Information System (INIS)

    Waller, W.C.; Cram, M.E.; Hall, J.E.

    1975-01-01

    For any measurement to have meaning, it must be related to generally accepted standard units by a valid and specified system of comparison. To calibrate well-logging tools, sensing systems are designed which produce consistent and repeatable indications over the range for which the tool was intended. The basics of calibration theory, procedures, and calibration record presentations are reviewed. Calibrations for induction, electrical, radioactivity, and sonic logging tools will be discussed. The authors' intent is to provide an understanding of the sources of errors, of the way errors are minimized in the calibration process, and of the significance of changes in recorded calibration data

  3. Status of ITER neutron diagnostic development

    Science.gov (United States)

    Krasilnikov, A. V.; Sasao, M.; Kaschuck, Yu. A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V. S.; Popovichev, S.; Iguchi, T.; Jarvis, O. N.; Källne, J.; Fiore, C. L.; Roquemore, A. L.; Heidbrink, W. W.; Fisher, R.; Gorini, G.; Prosvirin, D. V.; Tsutskikh, A. Yu.; Donné, A. J. H.; Costley, A. E.; Walker, C. I.

    2005-12-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented.

  4. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Krasilnikov, A.V.; Sasao, M.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Iguchi, T.; Jarvis, O.N.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Prosvirin, D.V.; Tsutskikh, A.Yu.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented

  5. Fire protection in Angra-2 nuclear power plant. The use of fire protection collars on plastic piping systems

    International Nuclear Information System (INIS)

    Oliveira Segabinaze, R. de

    1994-01-01

    The object of this paper is to briefly the use of fire protection collars on plastic piping systems passing through wall and floor penetration. The fire protection collars consist of a stainless steel housing, in which the leading edges of two pivoting plates are in constant pressure contact with the pipe. In case of fire these plates react on the softened pipe with a guillotine action, thereby stopping the flow; within the housing a foam material expands to fill the space when subject to the heat of the fire. The piping project has to be modified to permit the fixing of the collars to walls and floor penetrations. (author). 2 refs, 9 figs

  6. Calibration Technique of the Irradiated Thermocouple using Artificial Neural Network

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Tae; Joung, Chang Young; Ahn, Sung Ho; Yang, Tae Ho; Heo, Sung Ho; Jang, Seo Yoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    To correct the signals, the degradation rate of sensors needs to be analyzed, and re-calibration of sensors should be followed periodically. In particular, because thermocouples instrumented in the nuclear fuel rod are degraded owing to the high neutron fluence generated from the nuclear fuel, the periodic re-calibration process is necessary. However, despite the re-calibration of the thermocouple, the measurement error will be increased until next re-calibration. In this study, based on the periodically calibrated temperature - voltage data, an interpolation technique using the artificial neural network will be introduced to minimize the calibration error of the C-type thermocouple under the irradiation test. The test result shows that the calculated voltages derived from the interpolation function have good agreement with the experimental sampling data, and they also accurately interpolate the voltages at arbitrary temperature and neutron fluence. That is, once the reference data is obtained by experiments, it is possible to accurately calibrate the voltage signal at a certain neutron fluence and temperature using an artificial neural network.

  7. Investigation of factors affecting the calibration of strain gage based transducers (''Goodzeit gages'') for SSC magnets

    International Nuclear Information System (INIS)

    Davidson, M.; Gilbertson, A.; Dougherty, M.

    1991-03-01

    These transducers are designed to measure stresses on SSC collared coils. They are individually calibrated with a bonded ten-stack of SSC inner coil cable by applying a known load and reading corresponding output from the gages. The transducer is supported by a notched ''backing plate'' that allows for bending of the gage beam during calibration or in use with an actual coil. Several factors affecting the calibration and use of the transducers are: the number of times a ''backing plate'' is used, the similarities or difficulties between bonded ten-stacks, and the differences between the ten-stacks and the coil they represent. The latter is probably the most important because a calibration curve is a model of how a transducer should react within a coil. If the model is wrong, the calibration curve is wrong. Information will be presented regarding differences in calibrations between Brookhaven National Labs (also calibrating these transducers) and Fermilab -- what caused these differences, the investigation into the differences between coils and ten-stacks and how they relate to transducer calibration, and some suggestions for future calibrations

  8. Response characteristics of selected personnel neutron dosimeters

    International Nuclear Information System (INIS)

    McDonald, J.C.; Fix, J.J.; Hadley, R.T.; Holbrook, K.L.; Yoder, R.C.; Roberson, P.L.; Endres, G.W.R.; Nichols, L.L.; Schwartz, R.B.

    1983-09-01

    Performance characteristics of selected personnel neutron dosimeters in current use at Department of Energy (DOE) facilities were determined from their evaluation of neutron dose equivalent received after irradiations with specific neutron sources at either the National Bureau of Standards (NBS) or the Pacific Northwest Laboratory (PNL). The characteristics assessed included: lower detection level, energy response, precision and accuracy. It was found that when all of the laboratories employed a common set of calibrations, the overall accuracy was approximately +-20%, which is within uncertainty expected for these dosimeters. For doses above 80 mrem, the accuracy improved to better than 10% when a common calibration was used. Individual differences found in this study may reflect differences in calibration technique rather than differences in the dose rates of actual calibration standards. Second, at dose rates above 100 mrem, the precision for the best participants was generally below +-10% which is also within expected limits for these types of dosimeters. The poorest results had a standard deviation of about +-25%. At the lowest doses, which were sometimes below the lower detection limit, the precision often approached or exceeded +-100%. Third, the lower level of detection for free field 252 Cf neutrons generally ranged between 20 and 50 mrem. Fourth, the energy dependence study provided a characterization of the response of the dosimeters to neutron energies far from the calibration energy. 11 references, 22 figures, 26 tables

  9. Synthesis Polarimetry Calibration

    Science.gov (United States)

    Moellenbrock, George

    2017-10-01

    Synthesis instrumental polarization calibration fundamentals for both linear (ALMA) and circular (EVLA) feed bases are reviewed, with special attention to the calibration heuristics supported in CASA. Practical problems affecting modern instruments are also discussed.

  10. Evaluation of neutron dosimetry techniques for well-logging operations

    International Nuclear Information System (INIS)

    Cummings, F.M.; Haggard, D.L.; Endres, G.W.R.

    1985-07-01

    Neutron dose and energy spectral measurements from 241 AmBe and a 14 MeV neutron generator were performed at a well-logging laboratory. The measurement technique included the tissue equivalent proportional counter, multisphere, two types of remmeters and five types of personnel neutron dosimeters. Several source configurations were used to attempt to relate data to field situations. The results of the measurements indicated that the thermoluminescent albedo dosimeter was the most appropriate personnel neutron dosimeter, and that the most appropriate calibration source would be the source normally employed in the field with the calibration source being used in the unmoderated configuration. 7 refs., 35 figs., 14 tabs

  11. ORNL calibrations facility

    International Nuclear Information System (INIS)

    Berger, C.D.; Gupton, E.D.; Lane, B.H.; Miller, J.H.; Nichols, S.W.

    1982-08-01

    The ORNL Calibrations Facility is operated by the Instrumentation Group of the Industrial Safety and Applied Health Physics Division. Its primary purpose is to maintain radiation calibration standards for calibration of ORNL health physics instruments and personnel dosimeters. This report includes a discussion of the radioactive sources and ancillary equipment in use and a step-by-step procedure for calibration of those survey instruments and personnel dosimeters in routine use at ORNL

  12. Personnel neutron dose assessment upgrade: Volume 1, Personnel neutron dosimetry assessment: [Final report

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Brackenbush, L.W.; Griffith, R.V.; Hankins, D.E.; Parkhurst, M.A.; Stroud, C.M.; Faust, L.G.; Vallario, E.J.

    1988-07-01

    This report provides guidance on the characteristics, use, and calibration criteria for personnel neutron dosimeters. The report is applicable for neutrons with energies ranging from thermal to less than 20 MeV. Background for general neutron dosimetry requirements is provided, as is relevant federal regulations and other standards. The characteristics of personnel neutron dosimeters are discussed, with particular attention paid to passive neutron dosimetry systems. Two of the systems discussed are used at DOE and DOE-contractor facilities (nuclear track emulsion and thermoluminescent-albedo) and another (the combination TLD/TED) was recently developed. Topics discussed in the field applications of these dosimeters include their theory of operation, their processing, readout, and interpretation, and their advantages and disadvantages for field use. The procedures required for occupational neutron dosimetry are discussed, including radiation monitoring and the wearing of dosimeters, their exchange periods, dose equivalent evaluations, and the documenting of neutron exposures. The coverage of dosimeter testing, maintenance, and calibration includes guidance on the selection of calibration sources, the effects of irradiation geometries, lower limits of detectability, fading, frequency of calibration, spectrometry, and quality control. 49 refs., 6 figs., 8 tabs

  13. Offshoring White-Collar Work: An Explorative Investigation of the Processes and Mechanisms in Two Danish Manufacturing Firms

    DEFF Research Database (Denmark)

    Slepniov, Dmitrij; Larsen, Marcus Møller; Wæhrens, Brian Vejrum

    2010-01-01

    of this paper is two folded: to explain why knowledge-intensive service work in manufacturing firms is increasingly subject to offshoring and to understand the effects of this process on integration mechanisms for the firms involved. The empirical part of the study is based on two qualitative case studies...... of Danish manufacturers, and on the basis of these, we first argue that the drivers of white-collar work offshoring in many respects are parallel to those of the earlier wave of blue-collar work offshoring. However, the existing offshoring and outsourcing frameworks do not necessarily adequately address....... By relating white-collar work offshoring to integration means companies instigate to manage it, we attempt to bridge the existing knowledge gaps and advance understanding of the process of white-collar work offshoring and its implications....

  14. Gray Wolf (Canis lupus) movements and behavior around a kill site and implications for GPS collar studies

    Science.gov (United States)

    Mech, L. David

    2011-01-01

    Global Positioning System (GPS) radio-collars are increasingly used to estimate Gray Wolf (Canis lupus) kill rates. In interpreting results from this technology, researchers make various assumptions about wolf behavior around kills, yet no detailed description of this behavior has been published. This article describes the behavior of six wolves in an area of constant daylight during 30 hours, from when the pack killed a Muskox (Ovibos moschatus) calf and yearling on Ellesmere Island, Nunavut, Canada, to when they abandoned the kill remains. Although this is only a single incident, it demonstrates one possible scenario of pack behavior around a kill. Combined with the literature, this observation supports placing a radio-collar on the breeding male to maximize finding kills via GPS collars and qualifying results depending on whatever other information is available about the collared wolf's pack.

  15. Neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi

    1988-01-01

    The thermal neutron absorption coefficient is essentially different from the X-ray absorption coefficient. Each substance has a characteristic absorption coefficient regardless of its density. Neutron deams have the following features: (1) neutrons are not transmitted efficiently by low molecular weight substances, (2) they are transmitted efficiently by heavy metals, and (3) the transmittance differs among isotopes. Thus, neutron beams are suitable for cheking for foreign matters in heavy metals and testing of composites consisting of both heavy and light materials. A neutron source generates fast neutrons, which should be converted into thermal neutrons by reducing their energy. Major neutron souces include nuclear reactors, radioisotopes and particle accelerators. Photographic films and television systems are mainly used to observe neutron transmission images. Computers are employed for image processing, computerized tomography and three-dimensional analysis. The major applications of neutron radiography include inspection of neclear fuel; evaluation of material for airplane; observation of fuel in the engine and oil in the hydraulic systems in airplanes; testing of composite materials; etc. (Nogami, K.)

  16. FORTY PLUS CLUBS AND WHITE-COLLAR MANHOOD DURING THE GREAT DEPRESSION

    Directory of Open Access Journals (Sweden)

    Gregory Wood

    2008-01-01

    Full Text Available As scholars of gender and labor have argued, chronic unemployment during the Great Depression precipitated a “crisis” of masculinity, compelling men to turn towards new industrial unions and the New Deal as ways to affirm work, breadwinning, and patriarchy as bases for manhood. But did all men experience this crisis? During the late 1930s, white-collar men organized groups called “Forty Plus Clubs” in response to their worries about joblessness and manhood. The clubs made it possible for unemployed executives to find new jobs, while at the same time recreating the male-dominated culture of the white-collar office. For male executives, Forty Plus Clubs precluded the Depression-era crisis of manhood, challenging the idea that the absence ofpaid employment was synonymous with the loss of masculinity.

  17. Effects of Collar Permeability on the Field Quality of the Large Aperture Quadrupoles for the LHC

    CERN Document Server

    Catalan-Lasheras, N; Kirby, G; Mess, K H; Ostojic, R; Russenschuck, Stephan

    2008-01-01

    The LHC contains a number of large aperture quadrupoles (MQY) in the insertions. The acceptance of these magnets was based on warm magnetic measurements performed before delivery to CERN. During the series production of the MQY quadrupoles, the permeability of the collars drifted from the nominal value, and effects on the transfer function and multipole components became evident. To study the effects on the magnetic field, variable permeability of the stainless-steel collars as a function of local field and temperature was introduced into a numerical model. Comparing the results with measured data, we could isolate the contribution of permeability deviation on the magnetic field quality. The extrapolation of transfer function and field multipoles to operating temperature and current gives the necessary offsets, which are compared with measurements on a reduced set of magnets.

  18. Influence of recovery method and centrifugation on epididymal sperm from collared peccaries (Pecari tajacu Linnaeus, 1758).

    Science.gov (United States)

    Bezerra, José Artur Brilhante; da Silva, Andréia Maria; Peixoto, Gislayne Christianne Xavier; da Silva, Mariana de Araújo; Franco de Oliveira, Moacir; Silva, Alexandre Rodrigues

    2014-05-01

    In order to establish protocols for gamete recovery from accidentally killed wild animals, or to take advantage of those slaughtered by captive breeders, we assess the influence of two methods on the recovery of epididymal sperm from collared peccaries, and verify the effect of centrifugation on such gametes. Genitalia from nine animals were used. For each animal, one epididymis was processed by flotation and the other was processed by retrograde flushing, both using a buffered media based on Tris. Following recovery, sperm were evaluated for motility, vigor, viability, functional membrane integrity, and morphology. A 1-mL aliquot of each sample was centrifuged, the supernatant removed, and the pellet suspended and evaluated as fresh samples. The sperm characteristics did not differ between the samples collected by flotation or retrograde flushing (P methods was affected by centrifugation. In conclusion, epididymal sperm from collared peccaries can be efficiently collected through flotation or retrograde flushing, but not when either is followed by centrifugation.

  19. Comparison of risk factors for tooth loss between professional drivers and white-collar workers: an internet survey

    OpenAIRE

    SUZUKI, Seitaro; YOSHINO, Koichi; TAKAYANAGI, Atsushi; ISHIZUKA, Yoichi; SATOU, Ryouichi; KAMIJO, Hideyuki; SUGIHARA, Naoki

    2015-01-01

    This cross-sectional study was conducted to examine tooth loss and associated factors among professional drivers and white-collar workers. The participants were recruited by applying screening procedures to a pool of Japanese registrants in an online database. The participants were asked to complete a self-reported questionnaire. A total of 592 professional drivers and 328 white-collar workers (male, aged 30 to 69 years) were analyzed. A multiple logistic regression analysis was performed to ...

  20. Response of six neutron survey meters in mixed fields of fast and thermal neutrons.

    Science.gov (United States)

    Kim, S I; Kim, B H; Chang, I; Lee, J I; Kim, J L; Pradhan, A S

    2013-10-01

    Calibration neutron fields have been developed at KAERI (Korea Atomic Energy Research Institute) to study the responses of commonly used neutron survey meters in the presence of fast neutrons of energy around 10 MeV. The neutron fields were produced by using neutrons from the (241)Am-Be sources held in a graphite pile and a DT neutron generator. The spectral details and the ambient dose equivalent rates of the calibration fields were established, and the responses of six neutron survey meters were evaluated. Four single-moderator-based survey meters exhibited an under-responses ranging from ∼9 to 55 %. DINEUTRUN, commonly used in fields around nuclear reactors, exhibited an over-response by a factor of three in the thermal neutron field and an under-response of ∼85 % in the mixed fields. REM-500 (tissue-equivalent proportional counter) exhibited a response close to 1.0 in the fast neutron fields and an under-response of ∼50 % in the thermal neutron field.

  1. First results of feral cats (Felis catus) monitored with GPS collars in New Zealand

    CSIR Research Space (South Africa)

    Recio, MR

    2010-04-01

    Full Text Available -monitoring of feral cats injection of 0.12?0.20 ml of Antisedan? (Atipamezone hydrochloride) reversed the effect of Domitor. Individuals were weighed, sexed and visually inspected, and fitted with a GPS data-logger collar (Sirtrack, Havelock North, NZ, http.... __________________________________________________________________________________________________________________________________________________________________ Sex Capture Tracking period No. of No. of potential Fix rate No. of fixes % of fixes date (days) fixes fixes percentage HDOP < 9 used...

  2. The impact of long working hours on psychosocial stress response among white-collar workers

    OpenAIRE

    LEE, Kyungjin; SUH, Chunhui; KIM, Jong-Eun; PARK, Jae Oh

    2016-01-01

    This study examined the association between long working hours and psychosocial stress responses. In total, 1,122 white-collar workers from a company in Korea completed self-administered questionnaires following a lecture about the study aim, procedures, and confidentiality. Psychosocial stress responses were evaluated using the Psychosocial Well-being Index - Short Form (PWI-SF), and psychosocial working conditions were evaluated with the Korean Occupational Stress Scale - Short Form (KOSS-S...

  3. Changing Workplaces to Reduce Work-Family Conflict: Schedule Control in a White-Collar Organization

    OpenAIRE

    Kelly, Erin L.; Moen, Phyllis; Tranby, Eric

    2011-01-01

    Work-family conflicts are common and consequential for employees, their families, and work organizations. Can workplaces be changed to reduce work-family conflict? Previous research has not been able to assess whether workplace policies or initiatives succeed in reducing work-family conflict or increasing work-family fit. Using longitudinal data collected from 608 employees of a white-collar organization before and after a workplace initiative was implemented, we investigate whether the initi...

  4. Effect of psychosocial factors on metabolic syndrome in male and female blue-collar workers.

    Science.gov (United States)

    Hwang, Won Ju; Lee, Chung Yul

    2014-01-01

    The purposes of this study were to examine the relationship between psychosocial factors and metabolic syndrome among male and female blue-collar workers, and which factors influence their metabolic syndrome by sex. A cross-sectional study was completed of 154 men and 80 women working at small companies in Korea. The data were collected through a structured questionnaire, blood test, and anthropometric and blood pressure measure. Metabolic syndrome was diagnosed from the results of blood test and the measurements of waist circumference and blood pressure. The prevalence of metabolic syndrome among male and female blue-collar workers was 24.0% and 7.5%, respectively. Multiple logistic regression analysis was performed to examine factors of metabolic syndrome associated with sex. After controlling for age, marital status, smoking, alcohol drinking, shift work, overtime work, and physical exercise, job stress (odds ratio [OR] = 3.10, P = 0.005) and risk perception (OR = 1.12, P = 0.016) were influencing factors for men, and low job stress (OR = 0.05, P = 0.04), low social support (OR = 1.51, P = 0.009), and risk perception (OR = 1.27, P = 0.023) for women. Metabolic syndrome among blue-collar workers is closely related to psychosocial factors, such as job stress, social support, and risk perception, with the effect of job stress a point of difference between men and women. Occupational health nurses should be cognizant of the importance of assessing the effect of psychosocial factors on cardiovascular risk for blue-collar workers. © 2012 The Authors. Japan Journal of Nursing Science © 2012 Japan Academy of Nursing Science.

  5. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Directory of Open Access Journals (Sweden)

    Yang Yang, Ying Fang, Xini Zhang, Junliang He, Weijie Fu

    2017-12-01

    Full Text Available The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively performed a weight-bearing dorsiflexion (WB-DF maneuver, drop jumps (DJs, and lay-up jumps (LJs. Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041 was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028 and power (p = 0.022 were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  6. Using Collar worn Sensors to Forecast Thermal Strain in Military Working Dogs

    Science.gov (United States)

    2016-04-22

    Using Collar-worn Sensors to Forecast Thermal Strain in Military Working Dogs James R. Williamson, Austin R. Hess, Christopher J. Smalt, Delsey M...these estimates for forecasting and monitoring thermal strain is assessed based on performance in out of sample prediction of core temperature (Tc...time step (100 Hz) from the magnitude of the three- dimensional acceleration vector, ai , which is independent of sensor orientation. Next, the

  7. Factors associated with utilization of traditional Chinese medicine by white collar foreign workers living in Taiwan

    OpenAIRE

    Deng Chung-Yeh; Tai Chen-Jei; Daly Maria; Chien Li-Yin

    2009-01-01

    Abstract Background Traditional Chinese medicine (TCM) has remained an integral part of Chinese culture and society for thousands of years. In Taiwan TCM is a recognized element of its National Health Insurance Scheme. However, there is no knowledge about how TCM is accessed by foreign workers from a non-Asian cultural background. The objectives of this study were to investigate the prevalence and patterns of TCM use among non-Asian white-collar workers living in Taiwan, and examine factors l...

  8. Long working hours and risk for hypertension in Japanese male white collar workers

    OpenAIRE

    Nakanishi, N; Yoshida, H; Nagano, K; Kawashimo, H; Nakamura, K; Tatara, K

    2001-01-01

    STUDY OBJECTIVE—To evaluate the association of long working hours with the risk for hypertension.
DESIGN—A five year prospective cohort study.
SETTING—Work site in Osaka, Japan.
PARTICIPANTS—941 hypertension free Japanese male white collar workers aged 35-54 years were prospectively examined by serial annual health examinations. Men in whom borderline hypertension and hypertension were found during repeated surveys were defined as incidental cases of borderline hypertension and hypertension.
...

  9. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-12-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion-extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  10. Thermalization of monoenergetic neutrons in a concrete room

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado, G.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Iniguez, M.P.; Martin M, A. [Universidad de Valladolid, (Spain)

    2006-07-01

    The thermalization of neutrons from monoenergetic neutron sources in a concrete room has been studied. During calibration of neutron detectors it is mandatory to make corrections due to neutron scattering produced by the room walls, therefore this factor must be known in advance. The scattered neutrons are thermalized and produce a neutron field that is directly proportional to source strength and inversely proportional to room total wall-surfaces, the proportional coefficient has been calculated for neutrons whose energy goes from 1 eV to 20 MeV. This coefficient was calculated using Monte Carlo methods for 150, 200 and 300 cm-radius spherical cavity, where monoenergetic neutrons were located at the center, along the spherical cavity radius neutron spectra were calculated at several source-to-detector distances inside the cavity. The obtained coefficient is almost three times larger than the factor normally utilized. (Author)

  11. Increased lung function decline in blue-collar workers exposed to welding fumes.

    Science.gov (United States)

    Thaon, Isabelle; Demange, Valérie; Herin, Fabrice; Touranchet, Annie; Paris, Christophe

    2012-07-01

    There is no consensus at the present time about the effect of welding on lung function decline. This study compared lung function decline between blue-collar workers exposed and not exposed to welding fumes in a French longitudinal cohort of 21,238 subjects aged 37 to 52 years at inclusion. Medical data, occupation, sector of activity, and spirometry were recorded twice by occupational physicians in 1990 and 1995. A job-exposure matrix was used to identify 503 male blue-collar workers exposed to welding fumes and 709 control subjects and to define the weekly duration of exposure to welding fumes. Baseline lung function parameters were higher in workers exposed to welding fumes than in control subjects. After a 5-year follow-up, welding-fume exposure was associated with a nonsignificant decline in FVC (P = .06) and FEV(1) (P = .07) after adjustment for age, pack-years, BMI, and baseline value of the parameter. A significant accelerated decline in FEV(1) (P = .046) was also observed in never smokers exposed to welding fumes. An “exposure-response” relationship was observed between FEV(1) decline and weekly duration of exposure to welding fumes in nonsmokers but not in smokers. Blue-collar workers exposed to welding fumes showed accelerated decline in lung function, which, in nonsmokers, was related to weekly duration of exposure.

  12. Fatigue as prognostic risk marker of mental sickness absence in white collar employees.

    Science.gov (United States)

    Roelen, C A M; Heymans, M W; van Rhenen, W; Groothoff, J W; Twisk, J W R; Bültmann, U

    2014-06-01

    To investigate fatigue as prognostic risk marker for identifying working employees at risk of long-term sickness absence (SA). At baseline, fatigue was measured in 633 white collar employees with the checklist individual strength (CIS) including scales for fatigue severity, reduced concentration, reduced motivation, and reduced physical activity. SA was medically certified by an occupational physician in the 3rd or 4th SA week with diagnostic codes according to the 10th version of the International Classification of Diseases. Medically certified SA was retrieved at the individual level from an occupational health register after 1-year follow-up. CIS scores were investigated as prognostic risk markers predicting medically certified SA and particularly SA certified as mental SA. 614 employees (N = 378 men and N = 236 women) had complete data and were eligible for analysis; 63 (10 %) had medically certified SA of whom 39 (6 %) had mental SA. Fatigue severity and total CIS scores were associated with medically certified SA in men, but poorly discriminated between men with and without medically certified SA. Fatigue severity, reduced concentration, reduced motivation, and total CIS scores were also associated with mental SA in men. CIS and its reduced concentration scale were valid prognostic risk markers of mental SA. CONCLUSION Fatigue was a prognostic risk marker of mental SA in white collar men. The CIS should be further validated as a screening tool for the risk of mental SA in white collar working populations.

  13. Characterization of Newcastle disease virus isolates obtained from Eurasian collared doves (Streptopelia decaocto) in Italy.

    Science.gov (United States)

    Terregino, Calogero; Cattoli, Giovanni; Grossele, Barbara; Bertoli, Elena; Tisato, Ernesto; Capua, Ilaria

    2003-02-01

    Eurasian collared doves (Streptopelia decaocto) are thought to originate from India and they have colonized, throughout the centuries, the Middle East and, more recently, Mediterranean countries such as Italy and Spain. In the present paper we report of the isolation and characterization of Newcastle disease viruses (NDV) obtained from Eurasian collared doves during 2000-2001, and compare them to isolates obtained from feral pigeons (Columba livia) during the same period. All isolates could be classified as avian paramyxovirus type 1 (APMV1) and belonged to the pigeon variant group (PPMV1), as their haemagglutinating activity was inhibited by mAb 161/617 which is specific for PPMV1. The intracerebral pathogenicity indices ranged from 0.68 to 1.38 and all isolates contained multiple basic amino acids at the deduced cleavage site of the fusion protein, which is a typical feature of virulent viruses. Phylogenetic analysis of the isolates indicate that 18/20 of these form a separate cluster from the isolates obtained from pigeons in the same period. These findings suggest that different lineages are circulating in feral pigeon populations, and that a separate lineage affects Eurasian collared doves.

  14. Determination of the emission rate for the 14 MeV neutron generator with the use of radio-yttrium

    OpenAIRE

    Laszynska Ewa; Jednorog Slawomir; Ziolkowski Adam; Gierlik Michal; Rzadkiewicz Jacek

    2015-01-01

    The neutron emission rate is a crucial parameter for most of the radiation sources that emit neutrons. In the case of large fusion devices the determination of this parameter is necessary for a proper assessment of the power release and the prediction for the neutron budget. The 14 MeV neutron generator will be used for calibration of neutron diagnostics at JET and ITER facilities. The stability of the neutron generator working parameters like emission and angular homogeneity affects the accu...

  15. Neutron detector

    Science.gov (United States)

    Stephan, Andrew C [Knoxville, TN; Jardret,; Vincent, D [Powell, TN

    2011-04-05

    A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

  16. Fusion neutronics

    CERN Document Server

    Wu, Yican

    2017-01-01

    This book provides a systematic and comprehensive introduction to fusion neutronics, covering all key topics from the fundamental theories and methodologies, as well as a wide range of fusion system designs and experiments. It is the first-ever book focusing on the subject of fusion neutronics research. Compared with other nuclear devices such as fission reactors and accelerators, fusion systems are normally characterized by their complex geometry and nuclear physics, which entail new challenges for neutronics such as complicated modeling, deep penetration, low simulation efficiency, multi-physics coupling, etc. The book focuses on the neutronics characteristics of fusion systems and introduces a series of theories and methodologies that were developed to address the challenges of fusion neutronics, and which have since been widely applied all over the world. Further, it introduces readers to neutronics design’s unique principles and procedures, experimental methodologies and technologies for fusion systems...

  17. Neutron spectometers

    International Nuclear Information System (INIS)

    Poortmans, F.

    1977-01-01

    Experimental work in the field of low-energy neutron physics can be subdivided into two classes: 1)Study of the decay process of the compound-nucleus state as for example the study of the capture gamma rays and of the neutron induced fission process; 2)Study of the reaction mechanism, mainly by measuring the reaction cross-sections and resonance parameters. These neutron cross-sections and resonance parameters are also important data required for many technological applications especially for reactor development programmes. In general, the second class of experiments impose other requirements on the neutron spectrometer than the first class. In most cases, a better neutron energy resolution and a broader neutron energy range are required for the study of the reaction mechanism than for the study of various aspects of the decay process. (author)

  18. Dose Evaluation of Neutron within Containment Building of a CE type Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Wook; Han, Jae Mun; Kim, Kyung Doek; Yun, Cheol Whan; Suh, Jang Soo; Kim, Young Jae [Nuclear Environment Technology Institute, Daejeon (Korea, Republic of)

    2005-03-15

    From measured results of the neutron fields at some principal places within the containment building in a CE type nuclear power plant in operation, the radiation exposure of a worker to the neutron at there was evaluated and the equivalent dose reflecting new recommendation (ICRP 60) was compared with that doing the old one (ICRP 26). The measured neutron field was also compared with calibration neutron field. From the analysis, the following conclusion was obtained: the average neutron radiation weighting factor according to new recommendation is 2.41 to 2.71 times higher than the old one. The average neutron radiation weighting factor at the measured place was similar to that at calibration neutron field. The average neutron energy at measured place was between 42 and 158 keV and higher than that of calibration field of 500 keV. So, the measured equivalent dose in nuclear power plant could be overestimated compared to the real equivalent dose.

  19. Neutron Spectrometry for Radiation Protection Purposes

    International Nuclear Information System (INIS)

    McDonald, Joseph C.

    2001-01-01

    Determination of the dose equivalent is required for radiation protection purposes, however such a determination is quite difficult for neutron radiation. In order to perform accurate dosimetric determinations, it is necessary to acquire information about the neutron fluence spectrum in the workplace as well as the reference radiations used to calibrate dosimetric instruments. This information can then be used to select the appropriate dosimetric instrument, the optimum calibration condition or to establish correction factors that account for the differences in calibration and workplace conditions. For quite some time, neutron spectrometry has been used for these purposes. A brief review of the applications of spectrometers in radiation protection and some recommendations for further development are given here

  20. Neutron spectrometry for radiation protection purposes

    CERN Document Server

    McDonald, J C; Alberts, W G

    2002-01-01

    Determination of the dose equivalent is required for radiation protection purposes, however such a determination is quite difficult for neutron radiation. In order to perform accurate dosimetric determinations, it is advantageous to acquire information about the neutron fluence spectrum in the workplace as well as the reference radiations used to calibrate dosimetric instruments. This information can then be used to select the appropriate dosimetric instrument, the optimum calibration condition or to establish correction factors that account for the differences in calibration and workplace conditions. For quite some time, neutron spectrometry has been used for these purposes. A brief review of the applications of spectrometers in radiation protection and some recommendations for further development are given here.

  1. Neutron exposure

    International Nuclear Information System (INIS)

    Prillinger, G.; Konynenburg, R.A. van

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. In chapter 6, LWR-PV neutron transport calculations and dosimetry methods and how they are combined to evaluate the neutron exposure of the steel of pressure vessels are discussed. An effort to correlate neutron exposure parameters with damage is made

  2. Neutron Albedo

    CERN Document Server

    Ignatovich, V K

    2005-01-01

    A new, algebraic, method is applied to calculation of neutron albedo from substance to check the claim that use of ultradispersive fuel and moderator of an active core can help to gain in size and mass of the reactor. In a model of isotropic distribution of incident and reflected neutrons it is shown that coherent scattering on separate grains in the case of thermal neutrons increases transport cross section negligibly, however it decreases albedo from a wall of finite thickness because of decrease of substance density. A visible increase of albedo takes place only for neutrons with wave length of the order of the size of a single grain.

  3. Influence of density and chemical composition of soils in the neutrons probes answer

    International Nuclear Information System (INIS)

    Crispino, Marcos Luiz; Antonino, Antonio Celso Dantas; Dall'Olio, Attilio; Oliveira Lira, Carlos Alberto Brayner de; Carneiro, Clemente J. Gusmao

    1996-08-01

    The determination of soil humidity with neutron probes is based in the measure of the thermal neutron flux intensity and its behavior with the soil depend: soil's chemical composition; soils physical parameters; neutrons' energetic spectrum and neutron-source detector geometry.The objective of this paper is to apply the multigroup function theory to calculate a neutron probe calibration curve utilizing representatives parameters and coefficients of soils horizons in a experimental station in Zona da Mata, Pernambuco, Brazil

  4. Nigerian Journal of Chemical Research 22 Vol,15, 2010 Neutron ...

    African Journals Online (AJOL)

    Hp

    techniques based on thermal neutron from a nuclear reactor in combination with high resolution gamma-ray ... calibration and validation of analytical procedure. The techniques have ... 6,7,8. ; Inductively. Coupled Plasma Atomic Emission.

  5. Portable system for periodical verification of area monitors for neutrons; Sistema portatil para verificacao periodica de monitores de area para neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luciane de R.; Leite, Sandro Passos; Lopes, Ricardo Tadeu, E-mail: rluciane@ird.gov.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Energia Nuclear; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da; Pereira, Walsan W., E-mail: karla@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI). Lab. de Neutrons

    2009-07-01

    The Neutrons Laboratory develops a project viewing the construction of a portable test system for verification of functioning conditions of neutron area monitors. This device will allow to the users the verification of the calibration maintenance of his instruments at the use installations, avoiding the use of an inadequate equipment related to his answer to the neutron beam response

  6. Dosimetry intercomparisons between fast neutron radiotherapy facilities

    International Nuclear Information System (INIS)

    Almond, P.R.; Smith, A.R.; Smathers, J.B.; Otte, V.A.

    1975-01-01

    Neutron dosimetry intercomparisons have been made between M.D. Anderson Hospital and Tumor Institute, Naval Research Laboratory, University of Washington Hospital, and Hammersmith Hospital. The parameters that are measured during these visits are: tissue kerma in air, tissue dose at depth of dose maximum, depth dose, beam profiles, neutron/gamma ratios and photon calibrations of ionization chambers. A preliminary report of these intercomparisons will be given including a comparison of the calculation and statement of tumor doses for each institution

  7. Quantitative analysis of boron by neutron radiography

    International Nuclear Information System (INIS)

    Bayuelken, A.; Boeck, H.; Schachner, H.; Buchberger, T.

    1990-01-01

    The quantitative determination of boron in ores is a long process with chemical analysis techniques. As nuclear techniques like X-ray fluorescence and activation analysis are not applicable for boron, only the neutron radiography technique, using the high neutron absorption cross section of this element, can be applied for quantitative determinations. This paper describes preliminary tests and calibration experiments carried out at a 250 kW TRIGA reactor. (orig.) [de

  8. Neutronic reactor

    International Nuclear Information System (INIS)

    Wende, C.W.J.

    1976-01-01

    A safety rod for a nuclear reactor has an inner end portion having a gamma absorption coefficient and neutron capture cross section approximately equal to those of the adjacent shield, a central portion containing materials of high neutron capture cross section and an outer end portion having a gamma absorption coefficient at least equal to that of the adjacent shield

  9. Neutron polarization

    International Nuclear Information System (INIS)

    Firk, F.W.K.

    1976-01-01

    Some recent experiments involving polarized neutrons are discussed; they demonstrate how polarization studies provide information on fundamental aspects of nuclear structure that cannot be obtained from more traditional neutron studies. Until recently, neutron polarization studies tended to be limited either to very low energies or to restricted regions at higher energies, determined by the kinematics of favorable (p, vector n) and (d, vector n) reactions. With the advent of high intensity pulsed electron and proton accelerators and of beams of vector polarized deuterons, this is no longer the case. One has entered an era in which neutron polarization experiments are now being carried out, in a routine way, throughout the entire range from thermal energies to tens-of-MeV. The significance of neutron polarization studies is illustrated in discussions of a wide variety of experiments that include the measurement of T-invariance in the β-decay of polarized neutrons, a search for the effects of meson exchange currents in the photo-disintegration of the deuteron, the determination of quantum numbers of states in the fission of aligned 235 U and 237 Np induced by polarized neutrons, and the double- and triple-scattering of fast neutrons by light nuclei

  10. Neutron holography

    International Nuclear Information System (INIS)

    Beynon, T.D.

    1986-01-01

    the paper concerns neutron holography, which allows an image to be constructed of the surfaces, as well as the interiors, of objects. The technique of neutron holography and its applications are described. Present and future use of the method is briefly outlined. (U.K.)

  11. Neutron Stars and NuSTAR

    Science.gov (United States)

    Bhalerao, Varun

    2012-05-01

    My thesis centers around the study of neutron stars, especially those in massive binary systems. To this end, it has two distinct components: the observational study of neutron stars in massive binaries with a goal of measuring neutron star masses and participation in NuSTAR, the first imaging hard X-ray mission, one that is extremely well suited to the study of massive binaries and compact objects in our Galaxy. The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing high energy X-ray telescope to orbit. NuSTAR has an order-of-magnitude better angular resolution and has two orders of magnitude higher sensitivity than any currently orbiting hard X-ray telescope. I worked to develop, calibrate, and test CdZnTe detectors for NuSTAR. I describe the CdZnTe detectors in comprehensive detail here - from readout procedures to data analysis. Detailed calibration of detectors is necessary for analyzing astrophysical source data obtained by the NuSTAR. I discuss the design and implementation of an automated setup for calibrating flight detectors, followed by calibration procedures and results. Neutron stars are an excellent probe of fundamental physics. The maximum mass of a neutron star can put stringent constraints on the equation of state of matter at extreme pressures and densities. From an astrophysical perspective, there are several open questions in our understanding of neutron stars. What are the birth masses of neutron stars? How do they change in binary evolution? Are there multiple mechanisms for the formation of neutron stars? Measuring masses of neutron stars helps answer these questions. Neutron stars in high-mass X-ray binaries have masses close to their birth mass, providing an opportunity to disentangle the role of "nature" and "nurture" in the observed mass distributions. In 2006, masses had been measured for only six such objects, but this small sample showed the greatest diversity in masses

  12. Calibration of Flick standards

    International Nuclear Information System (INIS)

    Thalmann, Ruedi; Spiller, Jürg; Küng, Alain; Jusko, Otto

    2012-01-01

    Flick standards or magnification standards are widely used for an efficient and functional calibration of the sensitivity of form measuring instruments. The results of a recent measurement comparison have shown to be partially unsatisfactory and revealed problems related to the calibration of these standards. In this paper the influence factors for the calibration of Flick standards using roundness measurement instruments are discussed in detail, in particular the bandwidth of the measurement chain, residual form errors of the device under test, profile distortions due to the diameter of the probing element and questions related to the definition of the measurand. The different contributions are estimated using simulations and are experimentally verified. Also alternative methods to calibrate Flick standards are investigated. Finally the practical limitations of Flick standard calibration are shown and the usability of Flick standards both to calibrate the sensitivity of roundness instruments and to check the filter function of such instruments is analysed. (paper)

  13. Neutron source

    International Nuclear Information System (INIS)

    Cason, J.L. Jr.; Shaw, C.B.

    1975-01-01

    A neutron source which is particularly useful for neutron radiography consists of a vessel containing a moderating media of relatively low moderating ratio, a flux trap including a moderating media of relatively high moderating ratio at the center of the vessel, a shell of depleted uranium dioxide surrounding the moderating media of relatively high moderating ratio, a plurality of guide tubes each containing a movable source of neutrons surrounding the flux trap, a neutron shield surrounding one part of each guide tube, and at least one collimator extending from the flux trap to the exterior of the neutron source. The shell of depleted uranium dioxide has a window provided with depleted uranium dioxide shutters for each collimator. Reflectors are provided above and below the flux trap and on the guide tubes away from the flux trap

  14. Neutron transport

    International Nuclear Information System (INIS)

    Berthoud, Georges; Ducros, Gerard; Feron, Damien; Guerin, Yannick; Latge, Christian; Limoge, Yves; Santarini, Gerard; Seiler, Jean-Marie; Vernaz, Etienne; Coste-Delclaux, Mireille; M'Backe Diop, Cheikh; Nicolas, Anne; Andrieux, Catherine; Archier, Pascal; Baudron, Anne-Marie; Bernard, David; Biaise, Patrick; Blanc-Tranchant, Patrick; Bonin, Bernard; Bouland, Olivier; Bourganel, Stephane; Calvin, Christophe; Chiron, Maurice; Damian, Frederic; Dumonteil, Eric; Fausser, Clement; Fougeras, Philippe; Gabriel, Franck; Gagnier, Emmanuel; Gallo, Daniele; Hudelot, Jean-Pascal; Hugot, Francois-Xavier; Dat Huynh, Tan; Jouanne, Cedric; Lautard, Jean-Jacques; Laye, Frederic; Lee, Yi-Kang; Lenain, Richard; Leray, Sylvie; Litaize, Olivier; Magnaud, Christine; Malvagi, Fausto; Mijuin, Dominique; Mounier, Claude; Naury, Sylvie; Nicolas, Anne; Noguere, Gilles; Palau, Jean-Marc; Le Pallec, Jean-Charles; Peneliau, Yannick; Petit, Odile; Poinot-Salanon, Christine; Raepsaet, Xavier; Reuss, Paul; Richebois, Edwige; Roque, Benedicte; Royer, Eric; Saint-Jean, Cyrille de; Santamarina, Alain; Serot, Olivier; Soldevila, Michel; Tommasi, Jean; Trama, Jean-Christophe; Tsilanizara, Aime; Behar, Christophe; Provitina, Olivier; Lecomte, Michael; Forestier, Alain; Bender, Alexandra; Parisot, Jean-Francois; Finot, Pierre

    2013-10-01

    This bibliographical note presents a reference book which addresses the study of neutron transport in matter, the study of conditions for a chain reaction and the study of modifications of matter composition due to nuclear reactions. This book presents the main nuclear data, their measurement, assessment and processing, and the spallation. It proposes an overview of methods applied for the study of neutron transport: basic equations and their derived forms, deterministic methods and Monte Carlo method of resolution of the Boltzmann equation, methods of resolution of generalized Bateman equations, methods of time resolution of space kinetics coupled equations. It presents the main calculation codes, discusses the qualification and experimental aspects, and gives an overview of neutron transport applications: neutron transport calculation of reactors, neutron transport coupled with other disciplines, physics of fuel cycle, criticality

  15. Passive detectors for neutron fluence measurement

    International Nuclear Information System (INIS)

    Holt, P.D.

    1985-01-01

    The use of neutron activation detectors (slow neutron detectors and threshold detectors) and fission track detectors for radiological protection purposes, principally in criticality dosimetry, dosimetry of pulsed accelerators and calibration of neutron fluxes is discussed. References are given to compilations of cross sections. For the determination of the activity induced, either beta ray or gamma ray counting may be used. For beta-ray counting, thin foils are usually necessary which result in low neutron sensitivity. When fission track detectors are used, it is necessary to know the efficiency of track registration. Alternatively, a detector-counter system may be calibrated by exposure to a known flux of monoenergetic neutrons. Usually, the sensitivity of activation detectors is low because small foils are used. For criticality dosimetry, calibration work and shielding studies on accelerators, low sensitivity is acceptable. However, there are some instances where, by the use of long integration times, or very large quantities of detector material with gamma ray detection, neutron fluences in operational areas have been measured. (author)

  16. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  17. Occupational contact dermatitis in blue-collar workers: results from a multicentre study from the Danish Contact Dermatitis Group (2003-2012).

    Science.gov (United States)

    Schwensen, Jakob F; Menné, Torkil; Veien, Niels K; Funding, Anne T; Avnstorp, Christian; Østerballe, Morten; Andersen, Klaus E; Paulsen, Evy; Mørtz, Charlotte G; Sommerlund, Mette; Danielsen, Anne; Andersen, Bo L; Thormann, Jens; Kristensen, Ove; Kristensen, Berit; Vissing, Susanne; Nielsen, Niels H; Thyssen, Jacob P; Johansen, Jeanne D

    2014-12-01

    Blue-collar workers have a high risk of occupational contact dermatitis, but epidemiological studies are scarce. To investigate allergic contact dermatitis in blue-collar workers with dermatitis registered by the Danish Contact Dermatitis Group. A retrospective analysis of patch test data from 1471 blue-collar workers and 1471 matched controls tested between 2003 and 2012 was performed. A logistic regression was used to test for associations. The blue-collar workers often had occupational hand dermatitis (p dermatitis was less commonly observed among blue-collar workers (19.6%) than among controls (23.9%) (p = 0.005). Allergens with a statistically significant association with the occupational group of blue-collar workers were epoxy resins, methyldibromo glutaronitrile, 2-bromo-2-nitro-1,3-propanediol, potassium dichromate, and methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI). The following occupations were additionally identified as risk factors for contact sensitization to MCI/MI and MI, epoxy resins, and potassium dichromate, respectively: painting, construction work, and tile setting/terrazzo work. Contact allergy is a major problem among blue-collar workers. The data indicate a healthy worker effect among blue-collar workers diagnosed with dermatitis, as blue-collar workers were diagnosed significantly less often with atopic dermatitis than were controls. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Applications of Bonner sphere detectors in neutron field dosimetry

    International Nuclear Information System (INIS)

    Awschalom, M.; Sanna, R.S.

    1983-09-01

    The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed

  19. Preliminary results of neutron production in Sahand plasma focus device

    International Nuclear Information System (INIS)

    Siahpoush, V.; Mohammadi, M.A.; Khorram, S.; Shabani, I.; Borhanian, J.; Ashrafi, S.; Naghshara, H.; Moslehi-Fard, M.; Sobhanian, S.

    2004-01-01

    We report in this paper the preliminary results of neutron generation during fusion reaction in deuterium in the Sahand Filipov type plasma focus, recently installed and put in operation at Tabriz University. The special calibration procedure for neutron detection system, using activation method is described

  20. Conceptual design of neutron diagnostic systems for fusion experimental reactor

    International Nuclear Information System (INIS)

    Iguchi, T.; Kaneko, J.; Nakazawa, M.

    1994-01-01

    Neutron measurement in fusion experimental reactors is very important for burning plasma diagnostics and control, monitoring of irradiation effects on device components, neutron source characterization for in-situ engineering tests, etc. A conceptual design of neutron diagnostic systems for an ITER-like fusion experimental reactor has been made, which consists of a neutron yield monitor, a neutron emission profile monitor and a 14-MeV spectrometer. Each of them is based on a unique idea to meet the required performances for full power conditions assumed at ITER operation. Micro-fission chambers of 235 U (and 238 U) placed at several poloidal angles near the first wall are adopted as a promising neutron yield monitor. A collimated long counter system using a 235 U fission chamber and graphite neutron moderators is also proposed to improve the calibration accuracy of absolute neutron yield determination

  1. Using MCNP for in-core instrument calibration in CANDU

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, D.C. [Point Lepreau Generating Station, NB Power, Lepreau, New Brunswick (Canada); Anghel, V.N.P.; Sur, B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    2002-07-01

    The calibration of in-core instruments is important for safe and economical CANDU operation. However, in-core detectors are not normally suited to bench calibration procedures. This paper describes the use and validation of detailed neutron transport calculations for the purpose of calibrating the response of in-core neutron flux detectors. The Monte-Carlo transport code, MCNP, was used to model the thermal neutron flux distribution in the region around self-powered in-core flux detectors (ICFDs), and in the vicinity of the calandria edge. The ICFD model was used to evaluate the reduction in signal of a given detector (the 'detector shading factor') due to neutron absorption in surrounding materials, detectors, and lead-cables. The calandria edge model was used to infer the accuracy of the calandria edge position from flux scans performed by AECL's traveling flux detector (TFD) system. The MCNP results were checked against experimental results on ICFDs, and also against shading factors computed by other means. The use of improved in-core detector calibration factors obtained by this new methodology will improve the accuracy of spatial flux control performance in CANDU-6 reactors. The accurate determination of TFD based calandria edge position is useful in the quantitative measurement of changes in in-core component dimensions and position due to aging, such as pressure tube sag. (author)

  2. Neutron therapy

    International Nuclear Information System (INIS)

    Riesler, Rudi

    1995-01-01

    Standard radiotherapy uses Xrays or electrons which have low LET (linear energy transfer); in contrast, particles such as neutrons with high LET have different radiobiological responses. In the late 1960s, clinical trials by Mary Catterall at the Hammersmith Hospital in London indicated that fast neutron radiation had clinical advantages for certain malignant tumours. Following these early clinical trials, several cyclotron facilities were built in the 1980s for fast neutron therapy, for example at the University of Washington, Seattle, and at UCLA. Most of these newer machines use extracted cyclotron proton beams in the range 42 to 66 MeV with beam intensities of 15 to 60 microamps. The proton beams are transported to dedicated therapy rooms, where neutrons are produced from beryllium targets. Second-generation clinical trials showed that accurate neutron beam delivery to the tumour site is more critical than for photon therapy. In order to achieve precise beam geometries, the extracted proton beams have to be transported through a gantry which can rotate around the patient and deliver beams from any angle; also the neutron beam outline (''field shape'') must be adjusted to extremely irregular shapes using a flexible collimation system. A therapy procedure has to be appropriately organized, with physicians, radiotherapists, nurses, medical physicists and other staff in attendance; other specialized equipment, such as CT or MRI scanners and radiation simulators must be made available. Neutron therapy is usually performed only in radiation oncology departments of major medical centres

  3. Neutron radiography

    International Nuclear Information System (INIS)

    Alaa eldin, M.T.

    2011-01-01

    The digital processing of the neutron radiography images gives the possibility for data quantification. In this case an exact relation between the measured neutron attenuation and the real macroscopic attenuation coefficient for every point of the sample is required. The assumption that the attenuation of the neutron beam through the sample is exponential is valid only in an ideal case where a monochromatic beam, non scattering sample and non background contribution are assumed. In the real case these conditions are not fulfilled and in dependence on the sample material we have more or less deviation from the exponential attenuation law. Because of the high scattering cross-sections of hydrogen (σs=80.26 barn) for thermal neutrons, the problem with the scattered neutrons at quantitative radiography investigations of hydrogenous materials (as PE, Oil, H 2 O, etc) is not trivial. For these strong scattering materials the neutron beam attenuation is no longer exponential and a dependence of the macroscopic attenuation coefficient on the material thickness and on the distance between the sample and the detector appears. When quantitative radiography (2 D) or tomography investigations (3 D) are performed, some image correction procedures for a description of the scattering effect are required. This thesis presents a method that can be used to enhance the neutron radiography image for objects with high scattering materials like hydrogen, carbon and other light materials. This method uses the Monte Carlo code, MCNP5, to simulate the neutron radiography process and get the flux distribution for each pixel of the image and determine the scattered neutrons distribution that causes the image blur and then subtract it from the initial image to improve its quality.

  4. Neutron calorimeter as a fusion diagnostic

    International Nuclear Information System (INIS)

    Proctor, A.E.; Nieschmidt, E.B.

    1986-01-01

    A calorimeter is described which is applicable as a fusion neutron diagnostic. The device has the following distinct advantages: low sensitivity to thermal neutrons, large dynamic range, small mass resulting in fair time resolution, small physical size, independent calibration, little shielding required, no heat loss to surroundings, and low cost. The heat generation is provided by neutron induced fissions in a foil of 235 U or 238 U. The effects, advantages, and disadvantages of these target materials are discussed. The expected time resolution and dynamic range are estimated for both target materials

  5. Neutron dosimetry of the Little Boy device

    International Nuclear Information System (INIS)

    Pederson, R.A.; Plassmann, E.A.

    1984-01-01

    Neutron dose rates at several angular locations and at distances out to 0.5 mile have been measured during critical operation of the Little Boy replica. We used modified remmetes and thermoluminescent dosimetry techniques for the measurements. The present status of our analysis is presented including estimates of the neutron-dose-relaxation length in air and the variation of the neutron-to-gamma-ray dose ratio with distance from the replica. These results are preliminary and are subject to detector calibration measurements

  6. Remarks on some rock neutron parameters

    International Nuclear Information System (INIS)

    Czubek, J.A.

    1983-01-01

    A method to calculate the thermal neutron parameters (absorption cross-section, diffusion coefficient and diffusion length) of rocks is given. It is based on a proper energy averaging of cross-sections for all rock matrix and rock saturating liquid constituents. Special emphasis is given to the presence of hydrogen. The diffusion lengths in different lithologies in the function of the variable rock porosity have been calculated. An influence of the thermal neutron spectrum on the shape of the porosity calibration curves for the dual spacing neutron method is shown. This influence has been estimated on two porosity units, on average. (author)

  7. 5th symposium on neutron dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Spurny, F

    1985-03-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of /sup 252/Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.).

  8. 5th symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.

    1985-01-01

    The symposium was held in Neuherberg near Munich on September 17-20, 1984 and was attended by 200 specialists from 20 coutries. The participants discussed the following areas of neutron dosimetry: basic concept and analysis of irradiation, basic data, proportional counters in radiation protection, detector response and spectrometry, enviromental monitoring, radiobiology and biophysical models, analysis of neutron fields, thermoluminescent detectors, personnel monitoring, calibration, measurement in the environment of 252 Cf sources, analysis of fields and detector response, standardization dosimetry, ionization chambers, planning of therapeutical irradiation study of depth dose distribution, facilities for neutron therapy and international comparison. (E.S.)

  9. Neutronics codes

    International Nuclear Information System (INIS)

    Buckel, G.

    1983-01-01

    The objectives are the development, testing and cultivation of reliable, efficient and user-optimized neutron-physical calculation methods and conformity with users' requirements concerning design of power reactors, planning and analysis of experiments necessary for their protection as well as research on physical key problems. A short outline of available computing programmes for the following objectives is given: - Provision of macroscopic group constants, - Calculation of neutron flux distribution in transport theory and diffusion approximation, - Evaluation of neutron flux-distribution, - Execution of disturbance calculations for the determination reactivity coefficients, and - graphical representation of results. (orig./RW) [de

  10. Detailed investigation of a time-of-flight neutron spectrometer

    International Nuclear Information System (INIS)

    Elevant, T.; Trostell, B.

    1981-02-01

    Properties of a neutron spectrometer and telescope, based on double neutron interaction in hydrogen based scintillators and neutron time-of-flight technique, have been investigated in detail. Theoretical scaling of the resolutions with the flight path length and scattering angle have been confirmed by experimental results. Important parameters in connection with calibration of the spectrometer are discussed and calculated relative resolutions of the ion temperature are shown when applied to a fusion deuterium plasma. (Auth.)

  11. LANSA: A large neutron scintillator array for neutron spectroscopy at Nova

    International Nuclear Information System (INIS)

    Nelson, M.B.; Cable, M.D.; Bennett, C.K.; Mant, G.

    1992-01-01

    A very sensitive neutron time-of-flight spectrometer is now in use at Nova. LANSA consists of 960 channels of a neutron sensitive liquid scintillator (10 x lO x lO cm) coupled to a photomultiplier tube followed by a discriminator, TDC and ADC to allow the measurement of neutron arrival time as well as pulse size. LANSA is capable of measuring yields as low as 2.3 x 10 5 DT neutrons (100 detected hits) with resolution of 2.3 ns (170 key for 14 MeV neutrons with 20 m flight path). Shielding and collimation provide background levels low enough to allow measurement of secondary and tertiary reaction neutrons. Details of design, testing, calibration and experimental results will be presented. This work was performed under the auspices of the US Department of Energy by Lawrence Livermore National Laboratory under contract No. W-7405-ENG-48

  12. Calibration of moisture monitors

    International Nuclear Information System (INIS)

    Gutierrez, R.L.

    1979-02-01

    A method for calibrating an aluminum oxide hygrometer against an optical chilled mirror dew-point hygrometer has been established. A theoretical cross-point line of dew points from both hygrometers and a maximum moisture content of 10 ppM/sub v/ are used to define an area for calibrating the sensor probes of the aluminum oxide hygrometer

  13. Site Calibration report

    DEFF Research Database (Denmark)

    Yordanova, Ginka; Vesth, Allan

    The report describes site calibration measurements carried out on a site in Denmark. The measurements are carried out in accordance to Ref. [1]. The site calibration is carried out before a power performance measurement on a given turbine to clarify the influence from the terrain on the ratio...

  14. Topics in Statistical Calibration

    Science.gov (United States)

    2014-03-27

    Natural cubic spline speed di st 110 B.2 The calibrate function The most basic calibration problem, the one often encountered in more advanced ...0040-1706, 1537-2723. A. M. Mood, F. A. Graybill, and D. C. Boes. Introduction to the Theory of Statistics. McGraw-Hill, Auckland , U.A, 1974. ISBN

  15. Physical aspects on the neutron irradiation. 4. Dosimetry with ionization chamber

    International Nuclear Information System (INIS)

    Hiraoka, Takeshi; Takada, Masashi

    2008-01-01

    Absolute measurements of the absorbed dose for irradiation are generally made using ionization chambers, which should be calibrated by the standard radiation source. The neutron dose measurements are not simple since gamma rays always contaminate the neutron flux and a variety of charged particles are induced by neutrons. Following subjects are described: (1) The method by ICRU 45 to estimate total dose of neutrons and gamma ray, (2) The method to measure the neutron dose and the gamma ray dose separately using paired ionization-chambers, and (3) The calibration of ionization chambers. The stability of the standard ionization-chambers is also presented. (K.Y.)

  16. 454 sequencing reveals extreme complexity of the class II Major Histocompatibility Complex in the collared flycatcher

    Directory of Open Access Journals (Sweden)

    Gustafsson Lars

    2010-12-01

    Full Text Available Abstract Background Because of their functional significance, the Major Histocompatibility Complex (MHC class I and II genes have been the subject of continuous interest in the fields of ecology, evolution and conservation. In some vertebrate groups MHC consists of multiple loci with similar alleles; therefore, the multiple loci must be genotyped simultaneously. In such complex systems, understanding of the evolutionary patterns and their causes has been limited due to challenges posed by genotyping. Results Here we used 454 amplicon sequencing to characterize MHC class IIB exon 2 variation in the collared flycatcher, an important organism in evolutionary and immuno-ecological studies. On the basis of over 152,000 sequencing reads we identified 194 putative alleles in 237 individuals. We found an extreme complexity of the MHC class IIB in the collared flycatchers, with our estimates pointing to the presence of at least nine expressed loci and a large, though difficult to estimate precisely, number of pseudogene loci. Many similar alleles occurred in the pseudogenes indicating either a series of recent duplications or extensive concerted evolution. The expressed alleles showed unambiguous signals of historical selection and the occurrence of apparent interlocus exchange of alleles. Placing the collared flycatcher's MHC sequences in the context of passerine diversity revealed transspecific MHC class II evolution within the Muscicapidae family. Conclusions 454 amplicon sequencing is an effective tool for advancing our understanding of the MHC class II structure and evolutionary patterns in Passeriformes. We found a highly dynamic pattern of evolution of MHC class IIB genes with strong signals of selection and pronounced sequence divergence in expressed genes, in contrast to the apparent sequence homogenization in pseudogenes. We show that next generation sequencing offers a universal, affordable method for the characterization and, in perspective

  17. Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading?

    Science.gov (United States)

    Siadat, Hakimeh; Pirmoazen, Salma; Beyabanaki, Elaheh; Alikhasi, Marzieh

    2015-07-01

    A significant vertical space that is corrected with vertical ridge augmentation may necessitate selection of longer abutments, which would lead to an increased vertical cantilever. This study investigated the influence of different abutment collar heights on single-unit dental implant screw-loosening after cyclic loading. Fifteen implant-abutment assemblies each consisted of an internal hexagonal implant were randomly assigned to 3 groups: Group1, consisting of 5 abutments with 1.5 mm gingival height (GH); Group2, 5 abutments with 3.5 mm GH; and Group3, 5 abutments with 5.5 mm GH. Each specimen was mounted in transparent auto-polymerizing acrylic resin block, and the abutment screw was tightened to 35 Ncm with an electric torque wrench. After 5 minutes, initial torque loss (ITL) was recorded for all specimens. Metal crowns were fabricated with 45° occlusal surface and were placed on the abutments. A cyclic load of 75 N and frequency of 1 Hz were applied perpendicular to the long axis of each specimen. After 500 000 cycles, secondary torque loss (STL) was recorded. One-way ANOVA analysis was used to evaluate the effects of abutment collar height before and after cyclic loading. One-way ANOVA showed that ITL among the groups was not significantly different (P = .52), while STL was significantly different among the groups (P = .008). Post-hoc Tukey HSD tests showed that STL values were significantly different between the abutments with 1.5 mm GH (Group1) and with 5.5 mm GH (Group3) (P = .007). A paired comparison t-test showed that cyclic loading significantly influenced the STL in comparison with the ITL in each group. Within the limitations of this study, it can be concluded that increase in height of the abutment collar could adversely affect the torque loss of the abutment screw.

  18. Evaluating methods for estimating home ranges using GPS collars: A comparison using proboscis monkeys (Nasalis larvatus).

    Science.gov (United States)

    Stark, Danica J; Vaughan, Ian P; Ramirez Saldivar, Diana A; Nathan, Senthilvel K S S; Goossens, Benoit

    2017-01-01

    The development of GPS tags for tracking wildlife has revolutionised the study of home ranges, habitat use and behaviour. Concomitantly, there have been rapid developments in methods for estimating habitat use from GPS data. In combination, these changes can cause challenges in choosing the best methods for estimating home ranges. In primatology, this issue has received little attention, as there have been few GPS collar-based studies to date. However, as advancing technology is making collaring studies more feasible, there is a need for the analysis to advance alongside the technology. Here, using a high quality GPS collaring data set from 10 proboscis monkeys (Nasalis larvatus), we aimed to: 1) compare home range estimates from the most commonly used method in primatology, the grid-cell method, with three recent methods designed for large and/or temporally correlated GPS data sets; 2) evaluate how well these methods identify known physical barriers (e.g. rivers); and 3) test the robustness of the different methods to data containing either less frequent or random losses of GPS fixes. Biased random bridges had the best overall performance, combining a high level of agreement between the raw data and estimated utilisation distribution with a relatively low sensitivity to reduced fixed frequency or loss of data. It estimated the home range of proboscis monkeys to be 24-165 ha (mean 80.89 ha). The grid-cell method and approaches based on local convex hulls had some advantages including simplicity and excellent barrier identification, respectively, but lower overall performance. With the most suitable model, or combination of models, it is possible to understand more fully the patterns, causes, and potential consequences that disturbances could have on an animal, and accordingly be used to assist in the management and restoration of degraded landscapes.

  19. Evaluating methods for estimating home ranges using GPS collars: A comparison using proboscis monkeys (Nasalis larvatus.

    Directory of Open Access Journals (Sweden)

    Danica J Stark

    Full Text Available The development of GPS tags for tracking wildlife has revolutionised the study of home ranges, habitat use and behaviour. Concomitantly, there have been rapid developments in methods for estimating habitat use from GPS data. In combination, these changes can cause challenges in choosing the best methods for estimating home ranges. In primatology, this issue has received little attention, as there have been few GPS collar-based studies to date. However, as advancing technology is making collaring studies more feasible, there is a need for the analysis to advance alongside the technology. Here, using a high quality GPS collaring data set from 10 proboscis monkeys (Nasalis larvatus, we aimed to: 1 compare home range estimates from the most commonly used method in primatology, the grid-cell method, with three recent methods designed for large and/or temporally correlated GPS data sets; 2 evaluate how well these methods identify known physical barriers (e.g. rivers; and 3 test the robustness of the different methods to data containing either less frequent or random losses of GPS fixes. Biased random bridges had the best overall performance, combining a high level of agreement between the raw data and estimated utilisation distribution with a relatively low sensitivity to reduced fixed frequency or loss of data. It estimated the home range of proboscis monkeys to be 24-165 ha (mean 80.89 ha. The grid-cell method and approaches based on local convex hulls had some advantages including simplicity and excellent barrier identification, respectively, but lower overall performance. With the most suitable model, or combination of models, it is possible to understand more fully the patterns, causes, and potential consequences that disturbances could have on an animal, and accordingly be used to assist in the management and restoration of degraded landscapes.

  20. MtDNA genetic diversity and structure of Eurasian Collared Dove (Streptopelia decaocto).

    Science.gov (United States)

    Bagi, Zoltán; Dimopoulos, Evangelos Antonis; Loukovitis, Dimitrios; Eraud, Cyril; Kusza, Szilvia

    2018-01-01

    The Eurasian Collared Dove (Streptopelia decaocto) is one of the most successful biological invaders among terrestrial vertebrates. However, little information is available on the genetic diversity of the species. A total of 134 Eurasian Collared Doves from Europe, Asia and the Caribbean (n = 20) were studied by sequencing a 658-bp length of mitochondrial DNA (mtDNA) cytochrome oxidase I (COI). Fifty-two different haplotypes and relatively high haplotype and nucleotide diversities (Hd±SD = 0.843±0.037 and π±SD = 0.026±0.013) were detected. Haplotype Ht1 was particularly dominant: it included 44.03% of the studied individuals, and contained sequences from 75% of the studied countries. Various analyses (FST, AMOVA, STRUCTURE) distinguished 2 groups on the genetic level, designated 'A' and 'B'. Two groups were also separated in the median-joining network and the maximum likelihood tree. The results of the neutrality tests were negative (Fu FS = -25.914; Tajima D = -2.606) and significantly different from zero (P≤0.001) for group A, whereas both values for group B were positive (Fu FS = 1.811; Tajima D = 0.674) and not significant (P>0.05). Statistically significant positive autocorrelation was revealed among individuals located up to 2000 km apart (r = 0.124; P = 0.001). The present results provide the first information on the genetic diversity and structure of the Eurasian Collared Dove, and can thereby serve as a factual and comparative basis for similar studies in the future.