WorldWideScience

Sample records for neutron activation sensor

  1. A militarily fielded thermal neutron activation sensor for landmine detection

    Energy Technology Data Exchange (ETDEWEB)

    Clifford, E.T.H. [Bubble Technology Industries, Chalk River (Canada); McFee, J.E. [Defence R and D Canada-Suffield, Medicine Hat (Canada)], E-mail: john.mcfee@drdc-rddc.gc.ca; Ing, H.; Andrews, H.R.; Tennant, D.; Harper, E. [Bubble Technology Industries, Chalk River (Canada); Faust, A.A. [Defence R and D Canada-Suffield, Medicine Hat (Canada)

    2007-08-21

    The Canadian Department of National Defence has developed a teleoperated, vehicle-mounted, multi-sensor system to detect anti-tank landmines on roads and tracks in peacekeeping operations. A key part of the system is a thermal neutron activation (TNA) sensor which is placed above a suspect location to within a 30 cm radius and confirms the presence of explosives via detection of the 10.835 MeV gamma ray associated with thermal neutron capture on {sup 14}N. The TNA uses a 100{mu}g{sup 252}Cf neutron source surrounded by four 7.62cmx7.62cm NaI(Tl) detectors. The system, consisting of the TNA sensor head, including source, detectors and shielding, the high-rate, fast pulse processing electronics and the data processing methodology are described. Results of experiments to characterize detection performance are also described. The experiments have shown that anti-tank mines buried 10 cm or less can be detected in roughly a minute or less, but deeper mines and mines significantly displaced horizontally take considerably longer time. Mines as deep as 30 cm can be detected for long count times (1000 s). Four TNA detectors are now in service with the Canadian Forces as part of the four multi-sensor systems, making it the first militarily fielded TNA sensor and the first militarily fielded confirmation sensor for landmines. The ability to function well in adverse climatic conditions has been demonstrated, both in trials and operations.

  2. Effect and suppression of parasitic surface damage in neutron irradiated CMOS Monolithic Active Pixel Sensors

    CERN Document Server

    Deveaux, M; Scharrer, P; Stroth, J

    2016-01-01

    CMOS Monolithic Active Pixel Sensors (MAPS) were chosen as sensor technology for the vertex detectors of STAR, CBM and the upgraded ALICE-ITS. They also constitute a valuable option for tracking devices at future e+e- colliders. Those applications require a substantial tolerance to both, ionizing and non-ionizing radiation. To allow for a focused optimization of the radiation tolerance, prototypes are tested by irradiating the devices either with purely ionizing radiation (e.g. soft X-rays) or the most pure sources of non-ionizing radiation available (e.g. reactor neutrons). In the second case, it is typically assumed that the impact of the parasitic $\\gamma$-rays found in the neutron beams is negligible. We checked this assumption by irradiating MAPS with $\\gamma$-rays and comparing the radiation damage generated with the one in neutron irradiated sensors. We conclude that the parasitic radiation doses may cause non-negligible radiation damage. Based on the results we propose a procedure to recognize and to ...

  3. Neutron radiation of an electronic sensor using coincidence method for an active dosimeter

    CERN Document Server

    Ndoye, A; Barelaud, B; Celerier, A; Decossas, J L; Vareille, J C

    1999-01-01

    Results on the modeling and experimentation on a preliminary structure to be used in neutron dosimetry are presented. The structure consists of a thin reactive layer deposited on two facing diodes. The sensor has been developed mainly to solve the problem of neutron dosimetry in the intermediate energy range (0.5 eV to 500 keV) for which the existing electronic systems are ineffective. The use of a coincidence method for the detection of the nuclear reaction products allows the discrimination of the gamma interactions. The system can also be used down to thermal energies for which the sensitivity is considerably higher. The sensor response depends on the thickness of the reactive layer which defines the neutron sensitivity and has an influence on the slowing down and absorption of emitted particles, the depletion layer which has to be optimized for a given energy range, the thickness of the dead layer of each detector. For experimentations with an Am-Be source, we have chosen following parameters: 100 nm for ...

  4. Variety of neutron sensors based on scintillating glass waveguides

    Science.gov (United States)

    Bliss, Mary; Craig, Richard A.

    1995-04-01

    Pacific Northwest Laboratory (PNL) has fabricated cerium-activated lithium silicate glass scintillating fiber waveguide neutron sensors via a hot-downdraw process. These fibers typically have a transmission length (e-1 length) of greater than 2 meters. The underlying physics of, the properties of, and selected devices incorporating these fibers are described. These fibers constitute an enabling technology for a wide variety of neutron sensors.

  5. Use of Apollo 17 Epoch Neutron Spectrum as a Benchmark in Testing LEND Collimated Sensor

    Science.gov (United States)

    Chin, Gordon; Sagdeev, R.; Milikh, G.

    2011-01-01

    The Apollo 17 neutron experiment LPNE provided a unique set of data on production of neutrons in the Lunar soil bombarded by Galactic Cosmic Rays (GCR). It serves as valuable "ground-truth" in the age of orbital remote sensing. We used the neutron data attributed to Apollo 17 epoch as a benchmark for testing the LEND's collimated sensor, as introduced by the geometry of collimator and efficiency of He3 counters. The latter is defined by the size of gas counter and pressure inside it. The intensity and energy spectrum of neutrons escaping the lunar surface are dependent on incident flux of Galactic Cosmic Rays (GCR) whose variability is associated with Solar Cycle and its peculiarities. We obtain first the share of neutrons entering through the field of view of collimator as a fraction of the total neutron flux by using the angular distribution of neutron exiting the Moon described by our Monte Carlo code. We computed next the count rate of the 3He sensor by using the neutron energy spectrum from McKinney et al. [JGR, 2006] and by consider geometry and gas pressure of the LEND sensor. Finally the neutron count rate obtained for the Apollo 17 epoch characterized by intermediate solar activity was adjusted to the LRO epoch characterized by low solar activity. It has been done by taking into account solar modulation potential, which affects the GCR flux, and in turn changes the neutron albedo flux.

  6. Development of a thermal neutron sensor for Humanitarian Demining.

    Science.gov (United States)

    Cinausero, M; Lunardon, M; Nebbia, G; Pesente, S; Viesti, G; Filippini, V

    2004-07-01

    A thermal neutron sensor prototype for Humanitarian Demining has been developed, trying to minimize cost and complexity of the system as required in such application. A (252)Cf source or a sealed-tube neutron generator is employed to produce primary fast neutrons that are thermalized in a moderator designed to optimize the neutron capture reaction yield in buried samples. A description of the sensor, including the performances of the acquisition system based on a Flash ADC card and final tests with explosive simulants are reported. A comparison of the sensor performance when using a radioactive source to that when employing a sealed-tube neutron generator is presented. Limitations and possible applications of this technique are discussed.

  7. Development of a thermal neutron sensor for Humanitarian Demining

    Energy Technology Data Exchange (ETDEWEB)

    Cinausero, M.; Lunardon, M. E-mail: lunardon@pd.infn.it; Nebbia, G.; Pesente, S.; Viesti, G.; Filippini, V

    2004-07-01

    A thermal neutron sensor prototype for Humanitarian Demining has been developed, trying to minimize cost and complexity of the system as required in such application. A {sup 252}Cf source or a sealed-tube neutron generator is employed to produce primary fast neutrons that are thermalized in a moderator designed to optimize the neutron capture reaction yield in buried samples. A description of the sensor, including the performances of the acquisition system based on a Flash ADC card and final tests with explosive simulants are reported. A comparison of the sensor performance when using a radioactive source to that when employing a sealed-tube neutron generator is presented. Limitations and possible applications of this technique are discussed.

  8. Enhanced NIF neutron activation diagnostics.

    Science.gov (United States)

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  9. Optimization of Thermal Neutron Converter in SiC Sensors for Spectral Radiation Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Krolikowski, Igor; Cetnar, Jerzy [Department of Nuclear Energy, Faculty of Energy and Fuels at AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Issa, Fatima; Ferrone, Raffaello; Ottaviani, Laurent [IM2NP, UMR CNRS 7334, Aix-Marseille University, Case 231, 13397 Marseille Cedex 20 (France); Szalkai, Dora; Klix, Axel [KIT- Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology, Karlsruhe 76344 (Germany); Vermeeren, Ludo [SCK-CEN, Boeretang 200, B-2400 Mol (Belgium); Lyoussi, Abdalla [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France); Saenger, Richard [Etudes et Productions Schlumberger, Clamart (France)

    2015-07-01

    Optimization of the neutron converter in SiC sensors is presented. The sensors are used for spectral radiation measurements of thermal and fast neutrons and optionally gamma ray at elevated temperature in harsh radiation environment. The neutron converter, which is based on 10B, allows to detect thermal neutrons by means of neutron capture reaction. Two construction of the sensors were used to measure radiation in experiments. Sensor responses collected in experiments have been reproduced by the computer tool created by authors, it allows to validate the tool. The tool creates the response matrix function describing the characteristic of the sensors and it was used for detailed analyses of the sensor responses. Obtained results help to optimize the neutron converter in order to increase thermal neutron detection. Several enhanced construction of the sensors, which includes the neutron converter based on {sup 10}B or {sup 6}Li, were proposed. (authors)

  10. Stability of the Hall sensors performance under neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Duran, I.; Hron, M.; Stockel, J. [Institute of Plasma Physics, Association EURATOM/IPP.CR, Praha (Czech Republic); Viererbl, L.; Vsolak, R.; Cerva, V. [Nuclear Research Institute plc (Czech Republic); Bolshakova, I.; Holyaka, R. [Lviv Polytechnic National Univ. (Ukraine); Vayakis, G. [ITER International Team, Naka Joint Work Site, Naka, Ibaraki (Japan)

    2004-07-01

    A principally new diagnostic method must be developed for magnetic measurements in steady state regime of operation of fusion reactor. One of the options is the use of transducers based on Hall effect. The use of Hall sensors in ITER is presently limited by their questionable radiation and thermal stability. Issues of reliable operation in ITER like radiation and thermal environment are addressed in the paper. The results of irradiation tests of candidate Hall sensors in LVR-15 and IBR-2 experimental fission reactors are presented. Stable operation (deterioration of sensitivity below one percent) of the specially prepared sensors was demonstrated during irradiation by the total fluence of 3.10{sup 16} n/cm{sup 2} in IBR-2 reactor. Increasing the total neutron fluence up to 3.10{sup 17} n/cm{sup 2} resulted in deterioration of the best sensor's output still below 10% as demonstrated during irradiation in LVR-15 fission reactor. This level of neutron is already higher than the expected ITER life time neutron fluence for a sensor location just outside the ITER vessel. (authors)

  11. Neutron Activation Analysis of Water - A Review

    Science.gov (United States)

    Buchanan, John D.

    1971-01-01

    Recent developments in this field are emphasized. After a brief review of basic principles, topics discussed include sources of neutrons, pre-irradiation physical and chemical treatment of samples, neutron capture and gamma-ray analysis, and selected applications. Applications of neutron activation analysis of water have increased rapidly within the last few years and may be expected to increase in the future.

  12. Evaluation of using a phototransistor as a neutron sensor

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Fabio R.; Santos, Luiz A.P., E-mail: fbarros@cnen.gov.b, E-mail: lasantos@cnen.gov.b [Centro Regional de Ciencias Nucleares, (CRCN/NE-CNEN-PE), Recife, PE (Brazil); Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Antonio Filho, Joao, E-mail: jaf@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2011-07-01

    The purpose of this paper is to evaluate some effects on the TEKT5400S phototransistor about the electrical and optical characteristics when it is exposed to the radiation from a neutron source of {sup 241} Am-{sup 9}Be, and therefore the study aims to verify if the phototransistor can be used as a neutron sensor. The neutrons interact with the crystal structure of the device yielding displacement of atoms in the semiconductor, creating defects in the phototransistor and these defects can modify its electrical state. To have a triplicate sample, five sets of three phototransistor were irradiated: one of them in thermal neutrons, three sets in fast neutrons, and the latter one was irradiated in a {sup 60} Co source to verify the contribution of gamma radiation in the device response. To understand the changes in the crystal structure, it was measured the dark current of the device, I, and plotting its (IxV) curve which is known in instrumentation as the characteristic curve of the electronic device. This technique aims to check how the phototransistor response is: the effect of accumulated dose; optical properties changing; and its permanence over time. The results showed that the device has some changing in the electrical and optical properties. It was also found that the response depends on the dose, D; it is linear up to 0.64 Gy; and the damage caused by the irradiation process is irreversible. Actually, such a damage is the parameter that is used to estimate the received dose by the phototransistor. Then one can conclude that a phototransistor type works as a neutron sensor depending on the knowledge of the the electrical state of the device, i.e., it is a function of its calibration curve: D(I). (author)

  13. Fast neutron activation dosimetry with TLDS

    Energy Technology Data Exchange (ETDEWEB)

    Pearson, D.W.; Moran, P.R.

    1975-01-01

    Fast neutron activation using threshold reactions is the only neutron dosimetry method which offers complete discrimination against gamma-rays and preserves some information about the neutron energy. Conventional activation foil technique requires sensitive radiation detectors to count the decay of the neutron induced activity. For extensive measurements at low neutron fluences, vast outlays of counting equipment are required. TL dosimeters are inexpensive, extremely sensitive radiation detectors. The work of Mayhugh et al. (Proc. Third Int. Conf. on Luminescence Dosimetry, Riso Report 249, 1040, (1971)) showed that CaSO/sub 4/: DyTLDs could be used to measure the integrated dose from the decay of the radioactivity produced in the dosimeters by exposure to thermal neutrons. This neatly combines the activation detector and counter functions in one solid state device. This work has been expanded to fast neutron exposures and other TL phosphors. The reactions /sup 19/F(n, 2n)/sup 18/F, /sup 32/S(n,p)/sup 32/P, /sup 24/Mg(n,p)/sup 24/, and /sup 64/Zn(n,p)/sup 64/Cu were found useful for fast neutron activation in commercial TLDs. As each TLD is its own integrating decay particle counter, many activation measurements can be made at the same time. The subsequent readings of the TL signals can be done serially after the induced radioactivity has decayed, using only one TL reader. The neutron detection sensitivity is limited mainly by the number statistics of the neutron activations. The precision of the neutron measurement is within a factor of two of conventional foil activation for comparable mass detectors. Commercially available TLDs can measure neutron fluences of 10/sup 9/n/cm/sup 2/ with 10 percent precision.

  14. A review of nanostructured based radiation sensors for neutron

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Pervaiz; Mohamed, Norani Muti; Burhanudin, Zainal Arif [Center of Excellence in Nanotechnology Department of Fundamental and Applied Sciences, Department of Electrical and Electronic Engineering Universiti Teknologi PETRONAS (Malaysia)

    2012-09-26

    Currently radiation sensors with various mechanisms such as radio thermo luminescence, radiographic and radiochromic film, semiconductor and ionization have been used for the detection of nuclear radiation. Sensitivity, handling procedure, heating condition, energy response, nonlinearity, polarization, non-uniform electric field, high bias voltage and spatial resolution due to large physical size are some of the key issues faced by these sensors. Due to the excellent electrical and mechanical properties, nanostructured materials such as carbon nanotubes (CNTs) have been researched as sensing elements in the sensors to overcome the mentioned problems. However CNTs are found to pose different problems, arising from the uncontrolled helicity and small cross-sectional area. Therefore, alternative sensing elements are still been sought after and the possibility of using boron nitride nanotubes for sensing neutron is considered in this review.

  15. Phase-sensitive two-dimensional neutron shearing interferometer and Hartmann sensor

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Kevin

    2015-12-08

    A neutron imaging system detects both the phase shift and absorption of neutrons passing through an object. The neutron imaging system is based on either of two different neutron wavefront sensor techniques: 2-D shearing interferometry and Hartmann wavefront sensing. Both approaches measure an entire two-dimensional neutron complex field, including its amplitude and phase. Each measures the full-field, two-dimensional phase gradients and, concomitantly, the two-dimensional amplitude mapping, requiring only a single measurement.

  16. Irradiation tests of ITER candidate Hall sensors using two types of neutron spectra.

    Science.gov (United States)

    Ďuran, I; Bolshakova, I; Viererbl, L; Sentkerestiová, J; Holyaka, R; Lahodová, Z; Bém, P

    2010-10-01

    We report on irradiation tests of InSb based Hall sensors at two irradiation facilities with two distinct types of neutron spectra. One was a fission reactor neutron spectrum with a significant presence of thermal neutrons, while another one was purely fast neutron field. Total neutron fluence of the order of 10(16) cm(-2) was accumulated in both cases, leading to significant drop of Hall sensor sensitivity in case of fission reactor spectrum, while stable performance was observed at purely fast neutron spectrum. This finding suggests that performance of this particular type of Hall sensors is governed dominantly by transmutation. Additionally, it further stresses the need to test ITER candidate Hall sensors under neutron flux with ITER relevant spectrum.

  17. The synchronous active neutron detection assay system

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Kendall, P.K.

    1994-08-01

    We have begun to develop a novel technique for active neutron assay of fissile material in spent nuclear fuel. This approach will exploit a 14-MeV neutron generator developed by Schlumberger. The technique, termed synchronous active neutron detection (SAND), follows a method used routinely in other branches of physics to detect very small signals in presence of large backgrounds. Synchronous detection instruments are widely available commercially and are termed ``lock-in`` amplifiers. We have implemented a digital lock-in amplifier in conjunction with the Schlumberger neutron generator to explore the possibility of synchronous detection with active neutrons. The Schlumberger system can operate at up to a 50% duty factor, in effect, a square wave of neutron yield. Results are preliminary but promising. The system is capable of resolving the fissile material contained in a small fraction of the fuel rods in a cold fuel assembly; it also appears resilient to background neutron interference. The interrogating neutrons appear to be non-thermal and penetrating. Work remains to fully explore relevant physics and optimize instrument design.

  18. Neutron counter based on beryllium activation

    Energy Technology Data Exchange (ETDEWEB)

    Bienkowska, B.; Prokopowicz, R.; Kaczmarczyk, J.; Paducha, M. [Institute of Plasma Physics and Laser Microfusion (IPPLM), Hery 23, 01-497 Warsaw (Poland); Scholz, M.; Igielski, A. [Institute of Nuclear Physics PAS (IFJPAN), Radzikowskiego 152, 31-342 Krakow (Poland); Karpinski, L. [Faculty of Electrical Engineering, Rzeszow University of Technology, Pola 2, 35-959 Rzeszow (Poland); Pytel, K. [National Centre for Nuclear Research (NCBJ), Soltana 7, 05-400 Otwock - Swierk (Poland)

    2014-08-21

    The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction {sup 9}Be(n, α){sup 6}He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, {sup 6}He, decays with half-life T{sub 1/2} = 0.807 s emitting β{sup −} particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β–particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β–source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5–the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β{sup −} particles emitted from radioactive {sup 6}He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

  19. Neutron counter based on beryllium activation

    Science.gov (United States)

    Bienkowska, B.; Prokopowicz, R.; Scholz, M.; Kaczmarczyk, J.; Igielski, A.; Karpinski, L.; Paducha, M.; Pytel, K.

    2014-08-01

    The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction 9Be(n, α)6He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, 6He, decays with half-life T1/2 = 0.807 s emitting β- particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β-particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β-source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5-the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β- particles emitted from radioactive 6He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

  20. Active Interrogation Using Electronic Neutron Generators for Nuclear Safeguards Applications

    Energy Technology Data Exchange (ETDEWEB)

    David L. Chichester; Edward H. Seabury

    2008-08-01

    Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. The most commonly used technique for performing active interrogation is to use an electronic neutron generator as the probe radiation source. Exploiting the unique operating characteristics of these devices, including their monoenergetic neutron emissions and their ability to operate in pulsed modes, presents a number of options for performing prompt and delayed signature analyses using both photon and neutron sensors. A review of literature in this area shows multiple applications of the active neutron interrogation technique for performing nuclear nonproliferation measurements. Some examples include measuring the plutonium content of spent fuel, assaying plutonium residue in spent fuel hull claddings, assaying plutonium in aqueous fuel reprocessing process streams, and assaying nuclear fuel reprocessing facility waste streams to detect and quantify fissile material. This paper discusses the historical use of this technique and examines its context within the scope and challenges of next-generation nuclear fuel cycles and advanced concept nuclear fuel cycle facilities.

  1. Overview of Ignitor Neutronics and Activation

    Science.gov (United States)

    Rollet, S.; Batistoni, P.; Forrest, R.

    1999-11-01

    The Ignitor experiment is designed to produce D-T plasmas where ignition can take place and the physics of α-particles can be studied. After a first period of operation without significant neutron production, a second phase in deuterium with 2.5 MeV neutron production rate up to 10^17 n/s is planned. This will be followed by operations at increasing percentages of tritium, leading to short, but intense 14 MeV neutron production, up to ≈ 3 × 10^19 n/s. To calculate the neutron fluxes in all the machine components, including the streaming through the ports, a detailed description of the actual Ignitor machine is implemented in the MCNP-4B Monte Carlo code. These fluxes are then used as input for the FISPACT-97 code for the analysis of the activation at the end of life (EOL) and at intermediate times for safety assessment purposes. The estimated neutron emission pulse results in rather modest neutron fluences (≈ 10^18 n/cm^2 on the first wall at EOL). Therefore, radiation damage in the device components is not a concern, with the possible exception of the toroidal magnet insulator. On the other hand, the neutron flux on the first wall can be as high as that of a demonstration reactor (≈ 10^14 n/s/cm^2), inducing, in the absence of a blanket, considerable activation. The shielding strategy and possible solutions to prevent/reduce the activation of the cryostat are presented.

  2. Feasibility of culvert IED detection using thermal neutron activation

    Science.gov (United States)

    Faust, Anthony A.; McFee, John E.; Clifford, Edward T. H.; Andrews, Hugh Robert; Mosquera, Cristian; Roberts, William C.

    2012-06-01

    Bulk explosives hidden in culverts pose a serious threat to the Canadian and allied armies. Culverts provide an opportunity to conceal insurgent activity, avoid the need for detectable surface disturbances, and limit the applicability of conventional sub-surface sensing techniques. Further, in spite of the large masses of explosives that can be employed, the large sensor{target separation makes detection of the bulk explosive content challeng- ing. Defence R&D Canada { Sueld and Bubble Technology Industries have been developing thermal neutron activation (TNA) sensors for detection of buried bulk explosives for over 15 years. The next generation TNA sensor, known as TNA2, incorporates a number of improvements that allow for increased sensor-to-target dis- tances, making it potentially feasible to detect large improvised explosive devices (IEDs) in culverts using TNA. Experiments to determine the ability of TNA2 to detect improvised explosive devices in culverts are described, and the resulting signal levels observed for relevant quantities of explosives are presented. Observations conrm that bulk explosives detection using TNA against a culvert-IED is possible, with large charges posing a detection challenge at least as dicult as that of a deeply buried anti-tank landmine. Because of the prototype nature of the TNA sensor used, it is not yet possible to make denitive statements about the absolute sensitivity or detection time. Further investigation is warranted.

  3. Passive neutron dosemeter with activation detector

    Energy Technology Data Exchange (ETDEWEB)

    Valero L, C.; Banuelos F, A.; Guzman G, K. A.; Borja H, C. G.; Hernandez D, V. M.; Vega C, H. R., E-mail: fermineutron@yahoo.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-10-15

    A passive neutron dosemeter with {sup 197}Au activation detector has been developed. The area dosemeter was made as a 20.5 {phi} x 20.5 cm{sup 2} polyethylene moderator, with a polyethylene pug where a {sup 197}Au foil can be located either parallel or perpendicular to moderator axis. Using Monte Carlo methods, with the MCNP5 code. With the fluence response and the fluence-to-equivalent dose conversion coefficients from ICRP-74, responses to H*(10) were also calculated, these were compared against responses of commercially available neutron area monitors and dosemeters. (Author)

  4. Opportunities for innovation in neutron activation analysis

    NARCIS (Netherlands)

    Bode, P.

    2011-01-01

    Neutron activation laboratories worldwide are at a turning point at which new staff has to be found for the retiring pioneers from the 1960s–1970s. A scientific career in a well-understood technique, often characterized as ‘mature’ may only be attractive to young scientists if still challenges for f

  5. Sensor Activation and Radius Adaptation (SARA) in Heterogeneous Sensor Networks

    CERN Document Server

    Bartolini, Novella; la Porta, Thomas; Petrioli, Chiara; Silvestri, Simone

    2010-01-01

    In this paper we address the problem of prolonging the lifetime of wireless sensor networks (WSNs) deployed to monitor an area of interest. In this scenario, a helpful approach is to reduce coverage redundancy and therefore the energy expenditure due to coverage. We introduce the first algorithm which reduces coverage redundancy by means of Sensor Activation and sensing Radius Adaptation (SARA)in a general applicative scenario with two classes of devices: sensors that can adapt their sensing range (adjustable sensors) and sensors that cannot (fixed sensors). In particular, SARA activates only a subset of all the available sensors and reduces the sensing range of the adjustable sensors that have been activated. In doing so, SARA also takes possible heterogeneous coverage capabilities of sensors belonging to the same class into account. It specifically addresses device heterogeneity by modeling the coverage problem in the Laguerre geometry through Voronoi-Laguerre diagrams. SARA executes quickly and is guarante...

  6. A neutron activation spectrometer and neutronic experimental platform for the National Ignition Facility (invited)

    Science.gov (United States)

    Yeamans, C. B.; Gharibyan, N.

    2016-11-01

    At the National Ignition Facility, the diagnostic instrument manipulator-based neutron activation spectrometer is used as a diagnostic of implosion performance for inertial confinement fusion experiments. Additionally, it serves as a platform for independent neutronic experiments and may be connected to fast recording systems for neutron effect tests on active electronics. As an implosion diagnostic, the neutron activation spectrometers are used to quantify fluence of primary DT neutrons, downscattered neutrons, and neutrons above the primary DT neutron energy created by reactions of upscattered D and T in flight. At a primary neutron yield of 1015 and a downscattered fraction of neutrons in the 10-12 MeV energy range of 0.04, the downscattered neutron fraction can be measured to a relative uncertainty of 8%. Significant asymmetries in downscattered neutrons have been observed. Spectrometers have been designed and fielded to measure the tritium-tritium and deuterium-tritium neutron outputs simultaneously in experiments using DT/TT fusion ratio as a direct measure of mix of ablator into the gas.

  7. Particle Filter-Based Recursive Data Fusion With Sensor Indexing for Large Core Neutron Flux Estimation

    Science.gov (United States)

    Tamboli, Prakash Kumar; Duttagupta, Siddhartha P.; Roy, Kallol

    2017-06-01

    We introduce a sequential importance sampling particle filter (PF)-based multisensor multivariate nonlinear estimator for estimating the in-core neutron flux distribution for pressurized heavy water reactor core. Many critical applications such as reactor protection and control rely upon neutron flux information, and thus their reliability is of utmost importance. The point kinetic model based on neutron transport conveniently explains the dynamics of nuclear reactor. The neutron flux in the large core loosely coupled reactor is sensed by multiple sensors measuring point fluxes located at various locations inside the reactor core. The flux values are coupled to each other through diffusion equation. The coupling facilitates redundancy in the information. It is shown that multiple independent data about the localized flux can be fused together to enhance the estimation accuracy to a great extent. We also propose the sensor anomaly handling feature in multisensor PF to maintain the estimation process even when the sensor is faulty or generates data anomaly.

  8. Neutron and gamma radiation tests of the Analog Devices TMP37 temperature sensors

    CERN Document Server

    Mockett, P M; Twomey, M S

    2004-01-01

    The Analog Devices TMP37 temperature sensor is used to monitor the temperature gradients in the US ATLAS End Cap Muon Chambers. It was chosen because of its stability, linearity, high output signal, and especially the low self-heating. We have irradiated samples of these sensors with neutrons and gamma rays. The results of these measurements are presented.

  9. Performance of an improved thermal neutron activation detector for buried bulk explosives

    Energy Technology Data Exchange (ETDEWEB)

    McFee, J.E., E-mail: jemcfee@gmail.com [Defence R and D Canada – Suffield, Medicine Hat (Canada); Faust, A.A. [Defence R and D Canada – Suffield, Medicine Hat (Canada); Andrews, H.R.; Clifford, E.T.H. [Bubble Technology Industries Inc., Chalk River (Canada); Mosquera, C.M. [Defence R and D Canada – Suffield, Medicine Hat (Canada)

    2013-06-01

    First generation thermal neutron activation (TNA) sensors, employing an isotopic source and NaI(Tl) gamma ray detectors, were deployed by Canadian Forces in 2002 as confirmation sensors on multi-sensor landmine detection systems. The second generation TNA detector is being developed with a number of improvements aimed at increasing sensitivity and facilitating ease of operation. Among these are an electronic neutron generator to increase sensitivity for deeper and horizontally displaced explosives; LaBr{sub 3}(Ce) scintillators, to improve time response and energy resolution; improved thermal and electronic stability; improved sensor head geometry to minimize spatial response nonuniformity; and more robust data processing. The sensor is described, with emphasis on the improvements. Experiments to characterize the performance of the second generation TNA in detecting buried landmines and improvised explosive devices (IEDs) hidden in culverts are described. Performance results, including comparisons between the performance of the first and second generation systems are presented.

  10. Fast neutron activation analysis by means of low voltage neutron generator

    Science.gov (United States)

    Medhat, M. E.

    A description of D-T neutron generator (NG) is presented. This machine can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. Procedure of neutron flux determination and efficiency calculation is described. Examples of testing some Egyptian natural cosmetics are given.

  11. Results on photon and neutron irradiation of semitransparent amorphous-silicon sensors

    CERN Document Server

    Carabe, J; Ferrando, A; Fuentes, J; Gandia, J J; Josa-Mutuberria, I; Molinero, A; Oller, J C; Arce, P; Calvo, E; Figueroa, C F; García, N; Matorras, F; Rodrigo, T; Vila, I; Virto, A L; Fenyvesi, A; Molnár, J; Sohler, D

    2000-01-01

    Semitransparent amorphous-silicon sensors are basic elements for laser 2D position reconstruction in the CMS multipoint alignment link system. Some of the sensors have to work in a very hard radiation environment. Two different sensor types have been irradiated with /sup 60/Co photons (up to 100 kGy) and fast neutrons (up to 10/sup 15 / cm/sup -2/), and the subsequent change in their performance has been measured. (13 refs).

  12. A new neutron monitor with silver activation

    CERN Document Server

    Luszik-Bhadra, M; Hohmann, E

    2010-01-01

    A moderator-type neutron monitor has been developed, which registers delayed beta rays from neutron-induced silver activation and which is able to measure dose equivalent in pulsed fields with peak dose rates of several thousand Sv h(-1). The monitor uses four silicon diodes in the centre of a polyethylene moderator, 30 cm in diameter. Two of the diodes are covered by natural silver foils and two of them by tin foils. The latter are used to subtract photon-induced pulses. For registering signals, a pulse height threshold is set at 662 key, which minimizes the effect of Cs-137 and lower energy radiation and - in addition - enhances the detection of beta rays from the shorter half-life silver isotope Ag-110 (25 s) as compared to the longer half-life isotope Ag-108 (144 s). The results of measurements in neutron and photon calibration fields, of MCNPX neutron response calculations and of first measurements in a high-intensity pulsed field at the PSI accelerator are shown. (c) 2010 Elsevier Ltd. All rights reserv...

  13. Displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor

    Directory of Open Access Journals (Sweden)

    Zujun Wang

    2014-07-01

    Full Text Available The experiments of displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor are presented. The CMOS APS image sensors are manufactured in the standard 0.35 μm CMOS technology. The flux of neutron beams was about 1.33 × 108 n/cm2s. The three samples were exposed by 1 MeV neutron equivalent-fluence of 1 × 1011, 5 × 1011, and 1 × 1012 n/cm2, respectively. The mean dark signal (KD, dark signal spike, dark signal non-uniformity (DSNU, noise (VN, saturation output signal voltage (VS, and dynamic range (DR versus neutron fluence are investigated. The degradation mechanisms of CMOS APS image sensors are analyzed. The mean dark signal increase due to neutron displacement damage appears to be proportional to displacement damage dose. The dark images from CMOS APS image sensors irradiated by neutrons are presented to investigate the generation of dark signal spike.

  14. Characterization of neutron transmutation doped (NTD) Ge for low temperature sensor development

    CERN Document Server

    Mathimalar, S; Dokania, N; Nanal, V; Pillay, R G; Pal, S; Ramakrishnan, S; Shrivastava, A; Maheshwari, Priya; Pujari, P K; Ojha, S; Kanjilal, D; Jagadeesan, K C; Thakare, S V

    2014-01-01

    Development of NTD Ge sensors has been initiated for low temperature (mK) thermometry in The India-based Tin detector (TIN.TIN). NTD Ge sensors are prepared by thermal neutron irradiation of device grade Ge samples at Dhruva reactor, BARC, Mumbai. Detailed measurements have been carried out in irradiated samples for estimating the carrier concentration and fast neutron induced defects. The Positron Annihilation Lifetime Spectroscopy (PALS) measurements indicated monovacancy type defects for all irradiated samples, while Channeling studies employing RBS with 2 MeV alpha particles, revealed no significant defects in the samples exposed to fast neutron fluence of $\\sim 4\\times10^{16}/cm^2$. Both PALS and Channeling studies have shown that vacuum annealing at 600 $^\\circ$C for $\\sim2$ hours is sufficient to recover the damage in the irradiated samples, thereby making them suitable for the sensor development.

  15. Introduction of Prompt Gamma Thermal Neutron Activation Analysis at CARR

    Institute of Scientific and Technical Information of China (English)

    WANG; Xing-hua; XIAO; Cai-jin; ZHANG; Gui-ying; YAO; Yong-gang; JIN; Xiang-chun; WANG; Ping-sheng; HUA; Long; NI; Bang-fa

    2013-01-01

    CARR will provide with maximal neutron flux in Asia,the third of the world.By using the high quality neutron beam and the advanced international experience,Prompt Gamma Neutron Activation Analysis(PGNAA)facility will be setup at high level.PGNAA on CARR will promote the development of nuclear analysis technology and improve Chinese status in the nuclear analysis field.

  16. Development and characterization of the integrated fiber-optic radiation sensor for the simultaneous detection of neutrons and gamma rays.

    Science.gov (United States)

    Jang, Kyoung Won; Lee, Bong Soo; Moon, Joo Hyun

    2011-04-01

    Sometimes, detection of thermal neutrons in the presence of gamma rays is required. This study developed and characterized an integrated fiber-optic radiation sensor for the simultaneous detection of thermal neutrons and gamma rays in a mixed radiation field. The performance of the integrated sensor was verified by measuring the distributions of thermal neutrons and gamma rays released from a nuclear fuel rod at the Kyoto University Critical Assembly. The experimental results show that the integrated sensor produced similar distribution patterns to those of thermal neutrons and gamma rays released from a fuel rod.

  17. Preliminary engineering assessment of the HCLL and HCPB Neutron Activation System

    Energy Technology Data Exchange (ETDEWEB)

    Calderoni, Pattrick; Leichtle, Dieter [Fusion for Energy, Barcelona, (Spain); Angelone, Maurizio [ENEA, Unita Tecnica Fusione, Frascati, (Italy); Klix, Axel [KIT, Eggenstein-Leopoldshafen, (Germany)

    2015-07-01

    The Neutron Activation System (NAS) is one of the four types of neutronics sensors considered for the testing of the HCLL and HCPB Test Blanket Module (TBM) in ITER. It measures the absolute neutron flux intensity with information on the neutron spectrum in selected positions of the TBM. The working principle of the NAS is as follows: the system moves small activation probes (capsules) into selected positions in the TBM (irradiation ends) by means of pneumatic transport with pressurized helium gas; the capsules are irradiated for a selected period, depending on their materials composition (several tens of seconds up to the full plasma pulse length); immediately after the irradiation they are extracted and transported to a gamma spectrometer by means of the same pneumatic transport system; the gamma spectrometer determines the induced gamma activity; the neutron flux and neutron fluence is calculated from the measured gamma activity and the known activation cross section of the materials in the activation probe; after the measurement the capsule is sent either to a disposal or storage (for later measurement). This paper summarizes the results of the feasibility assessment of the TBM NAS in the conceptual design phase, including design justification, identification of requirements based on the expected operating conditions in ITER and preliminary engineering assessment of the activation materials, irradiation ends integration in the modules design and the counting station. (authors)

  18. Neutron activation analysis: Modelling studies to improve the neutron flux of Americium-Beryllium source

    Energy Technology Data Exchange (ETDEWEB)

    Didi, Abdessamad; Dadouch, Ahmed; Tajmouati, Jaouad; Bekkouri, Hassane [Advanced Technology and Integration System, Dept. of Physics, Faculty of Science Dhar Mehraz, University Sidi Mohamed Ben Abdellah, Fez (Morocco); Jai, Otman [Laboratory of Radiation and Nuclear Systems, Dept. of Physics, Faculty of Sciences, Tetouan (Morocco)

    2017-06-15

    Americium–beryllium (Am-Be; n, γ) is a neutron emitting source used in various research fields such as chemistry, physics, geology, archaeology, medicine, and environmental monitoring, as well as in the forensic sciences. It is a mobile source of neutron activity (20 Ci), yielding a small thermal neutron flux that is water moderated. The aim of this study is to develop a model to increase the neutron thermal flux of a source such as Am-Be. This study achieved multiple advantageous results: primarily, it will help us perform neutron activation analysis. Next, it will give us the opportunity to produce radio-elements with short half-lives. Am-Be single and multisource (5 sources) experiments were performed within an irradiation facility with a paraffin moderator. The resulting models mainly increase the thermal neutron flux compared to the traditional method with water moderator.

  19. Improved Fission Neutron Data Base for Active Interrogation of Actinides

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Sara; Czirr, J. Bart; Haight, Robert; Kovash, Michael; Tsvetkov, Pavel

    2013-11-06

    This project will develop an innovative neutron detection system for active interrogation measurements. Many active interrogation methods to detect fissionable material are based on the detection of neutrons from fission induced by fast neutrons or high-energy gamma rays. The energy spectrum of the fission neutrons provides data to identify the fissionable isotopes and materials such as shielding between the fissionable material and the detector. The proposed path for the project is as follows. First, the team will develop new neutron detection systems and algorithms by Monte Carlo simulations and bench-top experiments. Next, They will characterize and calibrate detection systems both with monoenergetic and white neutron sources. Finally, high-fidelity measurements of neutron emission from fissions induced by fast neutrons will be performed. Several existing fission chambers containing U-235, Pu-239, U-238, or Th-232 will be used to measure the neutron-induced fission neutron emission spectra. The challenge for making confident measurements is the detection of neutrons in the energy ranges of 0.01 – 1 MeV and above 8 MeV, regions where the basic data on the neutron energy spectrum emitted from fission is least well known. In addition, improvements in the specificity of neutron detectors are required throughout the complete energy range: they must be able to clearly distinguish neutrons from other radiations, in particular gamma rays and cosmic rays. The team believes that all of these challenges can be addressed successfully with emerging technologies under development by this collaboration. In particular, the collaboration will address the area of fission neutron emission spectra for isotopes of interest in the advanced fuel cycle initiative (AFCI).

  20. Characterization of a boron carbide-based polymer neutron sensor

    Science.gov (United States)

    Tan, Chuting; James, Robinson; Dong, Bin; Driver, M. Sky; Kelber, Jeffry A.; Downing, Greg; Cao, Lei R.

    2015-12-01

    Boron is used widely in thin-film solid-state devices for neutron detection. The film thickness and boron concentration are important parameters that relate to a device's detection efficiency and capacitance. Neutron depth profiling was used to determine the film thicknesses and boron-concentration profiles of boron carbide-based polymers grown by plasma enhanced chemical vapor deposition (PECVD) of ortho-carborane (1,2-B10C2H12), resulting in a pure boron carbide film, or of meta-carborane (1,7-B10C2H12) and pyridine (C5H5N), resulting in a pyridine composite film, or of pyrimidine (C4H4N2) resulting in a pure pyrimidine film. The pure boron carbide film had a uniform surface appearance and a constant thickness of 250 nm, whereas the thickness of the composite film was 250-350 nm, measured at three different locations. In the meta-carborane and pyridine composite film the boron concentration was found to increase with depth, which correlated with X-ray photoelectron spectroscopy (XPS)-derived atomic ratios. A proton peak from 14N (n,p)14C reaction was observed in the pure pyrimidine film, indicating an additional neutron sensitivity to nonthermal neutrons from the N atoms in the pyrimidine.

  1. Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

    CERN Document Server

    Davis, John R; Vetter, Kai

    2016-01-01

    In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. The expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate. Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. Three areas analyzed in San Francisco, Downtown Oakland, and Berkeley all demonstrated a suppression in the backg...

  2. Real-time detection of fast and thermal neutrons in radiotherapy with CMOS sensors

    Science.gov (United States)

    Arbor, Nicolas; Higueret, Stephane; Elazhar, Halima; Combe, Rodolphe; Meyer, Philippe; Dehaynin, Nicolas; Taupin, Florence; Husson, Daniel

    2017-03-01

    The peripheral dose distribution is a growing concern for the improvement of new external radiation modalities. Secondary particles, especially photo-neutrons produced by the accelerator, irradiate the patient more than tens of centimeters away from the tumor volume. However the out-of-field dose is still not estimated accurately by the treatment planning softwares. This study demonstrates the possibility of using a specially designed CMOS sensor for fast and thermal neutron monitoring in radiotherapy. The 14 microns-thick sensitive layer and the integrated electronic chain of the CMOS are particularly suitable for real-time measurements in γ/n mixed fields. An experimental field size dependency of the fast neutron production rate, supported by Monte Carlo simulations and CR-39 data, has been observed. This dependency points out the potential benefits of a real-time monitoring of fast and thermal neutron during beam intensity modulated radiation therapies.

  3. Chemical weapons detection by fast neutron activation analysis techniques

    Science.gov (United States)

    Bach, P.; Ma, J. L.; Froment, D.; Jaureguy, J. C.

    1993-06-01

    A neutron diagnostic experimental apparatus has been tested for nondestructive verification of sealed munitions. Designed to potentially satisfy a significant number of van-mobile requirements, this equipment is based on an easy to use industrial sealed tube neutron generator that interrogates the munitions of interest with 14 MeV neutrons. Gamma ray spectra are detected with a high purity germanium detector, especially shielded from neutrons and gamma ray background. A mobile shell holder has been used. Possible configurations allow the detection, in continuous or in pulsed modes, of gamma rays from neutron inelastic scattering, from thermal neutron capture, and from fast or thermal neutron activation. Tests on full scale sealed munitions with chemical simulants show that those with chlorine (old generation materials) are detectable in a few minutes, and those including phosphorus (new generation materials) in nearly the same time.

  4. Measurements of fusion neutron yields by neutron activation technique: Uncertainty due to the uncertainty on activation cross-sections

    Energy Technology Data Exchange (ETDEWEB)

    Stankunas, Gediminas, E-mail: gediminas.stankunas@lei.lt [Lithuanian Energy Institute, Laboratory of Nuclear Installation Safety, Breslaujos str. 3, LT-44403 Kaunas (Lithuania); EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Batistoni, Paola [ENEA, Via E. Fermi, 45, 00044 Frascati, Rome (Italy); EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Sjöstrand, Henrik; Conroy, Sean [Department of Physics and Astronomy, Uppsala University, PO Box 516, SE-75120 Uppsala (Sweden); EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2015-07-11

    The neutron activation technique is routinely used in fusion experiments to measure the neutron yields. This paper investigates the uncertainty on these measurements as due to the uncertainties on dosimetry and activation reactions. For this purpose, activation cross-sections were taken from the International Reactor Dosimetry and Fusion File (IRDFF-v1.05) in 640 groups ENDF-6 format for several reactions of interest for both 2.5 and 14 MeV neutrons. Activation coefficients (reaction rates) have been calculated using the neutron flux spectra at JET vacuum vessel, both for DD and DT plasmas, calculated by MCNP in the required 640-energy group format. The related uncertainties for the JET neutron spectra are evaluated as well using the covariance data available in the library. These uncertainties are in general small, but not negligible when high accuracy is required in the determination of the fusion neutron yields.

  5. Neutron Activation Analysis of Inhomogeneous Large Samples; An Explorative Study

    NARCIS (Netherlands)

    Baas, H.W.

    2004-01-01

    Neutron activation analysis is a powerful technique for the determination of trace-element concentrations. Since both neutrons that are used for activation and gamma rays that are detected have a high penetrating power, the technique can be applied for relatively large samples (up to 13 L), as demon

  6. Development of educational program for neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Ryel, Sung; Kang, Young Hwan; Lee, Kil Yong; Yeon, Yeon Yel; Cho, Seung Yeon

    2000-08-01

    This technical report is developed to apply an educational and training program for graduate student and analyst utilizing neutron activation analysis. The contents of guide book consists of five parts as follows; introduction, gamma-ray spectrometry and measurement statistics, its applications, to understand of comprehensive methodology and to utilize a relevant knowledge and information on neutron activation analysis.

  7. Activity report on neutron scattering research

    Energy Technology Data Exchange (ETDEWEB)

    Nagao, M.; Tawata, N.; Fujii, Y. [eds.] [Tokyo Univ. (Japan). Inst. for Solid State Physics

    1998-12-31

    The experiments performed on the thirteen university-owned spectrometers installed at JRR-3M of JAERI in the fiscal year of 1997 were described in this report. The latest ``Neutron News`` (vol. 9, issue 3, 1998) has featured highlights of the activities based on the JRR-3M and its cover displays a graph showing an endless increase of the number of proposals to the users program in the fiscal 1997. The university-owned spectrometers are available for general users all over Japan. The users` requirement for a higher flux beam reactor became larger and larger with time. Thus, JAERI has refurbished JRR-3 to satisfy these demands. In 1997, a joint project between Chiba University and Institute for Solid State Physics (ISSP) started to build a new 4-cycle diffractometer for crystal physics/chemistry at T{sub 2-2} beam port on a thermal guide. (M.N.)

  8. New Measurements and Calculations to Characterize the Caliban Pulsed Reactor Cavity Neutron Spectrum by the Foil Activation Method

    Energy Technology Data Exchange (ETDEWEB)

    Jacquet, X.; Casoli, P.; Authier, N.; Rousseau, G. [CEA, Centre de Valduc, 21120 Is-sur-Tille (France); Barsu, C. [Pl. de la fontaine, 25410 Corcelles-Ferrieres (France)

    2011-07-01

    Caliban is a cylindrical metallic core reactor mainly composed of uranium 235. It is operated by the Criticality and Neutron Science Research Laboratory located at the French Atomic Energy Commission research center in Valduc. As with other fast burst reactors, Caliban is used extensively for determining the responses of electronic parts or other objects and materials to neutron-induced displacements. Therefore, Caliban's irradiation characteristics, and especially its central cavity neutron spectrum, have to be very accurately evaluated. The foil activation method has been used in the past by the Criticality and Neutron Science Research Laboratory to evaluate the neutron spectrum of the different facilities it operated, and in particular to characterize the Caliban cavity spectrum. In order to strengthen and to improve our knowledge of the Caliban cavity neutron spectrum and to reduce the uncertainties associated with the available evaluations, new measurements have been performed on the reactor and interpreted by the foil activation method. A sensor set has been selected to sample adequately the studied spectrum. Experimental measured reaction rates have been compared to the results from UMG spectrum unfolding software and to values obtained with the activation code Fispact. Experimental and simulation results are overall in good agreement, although gaps exist for some sensors. UMG software has also been used to rebuild the Caliban cavity neutron spectrum from activation measurements. For this purpose, a default spectrum is needed, and one has been calculated with the Monte-Carlo transport code Tripoli 4 using the benchmarked Caliban description. (authors)

  9. A dosimetry study of deuterium-deuterium neutron generator-based in vivo neutron activation analysis

    Science.gov (United States)

    Sowers, Daniel A.

    A neutron irradiation cavity for in vivo Neutron Activation Analysis (IVNAA) to detect manganese, aluminum, and other potentially toxic elements in human hand bone has been designed and its dosimetric specifications measured. The neutron source is a customized deuterium-deuterium neutron generator which produces neutrons at 2.45 MeV by the fusion reaction 2H(d, n)3He at a calculated flux of 7 x 108 +/-30% s-1. A moderator/reflector/shielding (5 cm high density polyethylene (HDPE), 5.3 cm graphite & 5.7 cm borated HDPE) assembly has been designed and built to maximize the thermal neutron flux inside the hand irradiation cavity and to reduce the extremity dose and effective dose to the human subject. Lead sheets are used to attenuate bremsstrahlung x rays and activation gammas. A Monte Carlo simulation (MCNP6) was used to model the system and calculate extremity dose. The extremity dose was measured with neutron and photon sensitive film badges and Fuji electronic pocket dosimeter (EPD). The neutron ambient dose outside the shielding was measured by Fuji NSN3, and photon dose by a Bicron MicroREM scintillator. Neutron extremity dose was calculated to be 32.3 mSv using MCNP6 simulations given a 10 min IVNAA measurement of manganese. Measurements by EPD and film badge indicate hand dose to be 31.7 +/- 0.8 mSv for neutron and 4.2 +/- 0.2 mSv for photon for 10 mins; whole body effective dose was calculated conservatively to be 0.052 mSv. Experimental values closely match values obtained from MCNP6 simulations. These are acceptable doses to apply the technology for a manganese toxicity study in a human population.

  10. Neutron activation analysis (NAA), radioisotope production via neutron activation (PNA) and fission product gas-jet (GJA)

    Energy Technology Data Exchange (ETDEWEB)

    Gaeggeler, H.W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-11-01

    Three different non-diffractive applications of neutrons are outlined, neutron activation analysis, production of radionuclides, mostly for medical applications, and production of short-lived fission nuclides with a so-called gas-jet. It is shown that all three devices may be incorporated into one single insert at SINQ due to their different requests with respect to thermal neutron flux. Some applications of these three facilities are summarized. (author) 3 figs., 1 tab., 8 refs.

  11. Self-shielding effects in neutron spectra measurements for neutron capture therapy by means of activation foils.

    Science.gov (United States)

    Pytel, Krzysztof; Józefowicz, Krystyna; Pytel, Beatrycze; Koziel, Alina

    2004-01-01

    The design and optimisation of a neutron beam for neutron capture therapy (NCT) is accompanied by the neutron spectra measurements at the target position. The method of activation detectors was applied for the neutron spectra measurements. Epithermal neutron energy region imposes the resonance structure of activation cross sections resulting in strong self-shielding effects. The neutron self-shielding correction factor was calculated using a simple analytical model of a single absorption event. Such a procedure has been applied to individual cross sections from pointwise ENDF/B-VI library and new corrected activation cross sections were introduced to a spectra unfolding algorithm. The method has been verified experimentally both for isotropic and for parallel neutron beams. Two sets of diluted and non-diluted activation foils covered with cadmium were irradiated in the neutron field. The comparison of activation rates of diluted and non-diluted foils has demonstrated the correctness of the applied self-shielding model.

  12. Activities on Nuclear Data Measurements at Pohang Neutron Facility

    Science.gov (United States)

    Kim, Guinyun

    2009-03-01

    We report the activities of the Pohang Neutron Facility which consists of an electron linear accelerator, a water-cooled Ta target, and a 12-m time-of-flight path. It has been equipped with a four-position sample changer controlled remotely by a CAMAC data acquisition system, which allows simultaneous accumulation of the neutron time of flight spectra from 4 different detectors. It can be possible to measure the neutron total cross-sections in the neutron energy range from 0.1 eV to few hundreds eV by using the neutron time-of-flight method. A 6LiZnS(Ag) glass scintillator was used as a neutron detector. The neutron flight path from the water-cooled Ta target to the neutron detector was 12.1 m. The background level was determined by using notch-filters of Co, In, Ta, and Cd sheets. In order to reduce the gamma rays from bremsstrahlung and those from neutron capture, we employed a neutron-gamma separation system based on their different pulse shapes. The present measurements of several samples (Ta, Mo) are in general agreement with the evaluated data in ENDF/B-VI. We measured the thermal neutron capture cross-sections and the resonance integrals of the 186W(n,γ)187W reaction and the 98Mo(n,γ)99Mo reaction by the activation method using the 197Au(n,γ)198Au monitor reaction as a single comparator. We also report the isomeric yield ratios for the 44 m, gSc isomeric pairs produced from four different photonuclear reactions 45Sc(γ,n)44m,gSc, natTi(γ,xn1p)44m,gSc, natFe(γ,xn5p)52m,gMn, and 103Rh(γ,4n)99m,gRh by using the activation method.

  13. The synchronous active neutron detection system for spent fuel assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Kendall, P.K.

    1994-10-01

    The authors have begun to develop a novel technique for active neutron assay of fissile material in spent nuclear fuel. This approach will exploit the unique operating features of a 14-MeV neutron generator developed by Schlumberger. This generator and a novel detection system will be applied to the direct measurement of the fissile material content in spent fuel in place of the indirect measures used at present. The technique they are investigating is termed synchronous active neutron detection (SAND). It closely follows a method that has been used routinely in other branches of physics to detect very small signals in the presence of large backgrounds. Synchronous detection instruments are widely available commercially and are termed {open_quotes}lock-in{close_quotes} amplifiers. The authors have implemented a digital lock-in amplifier in conjunction with the Schlumberger neutron generator to explore the possibility of synchronous detection with active neutrons. This approach is possible because the Schlumberger system can operate at up to a 50% duty factor, in effect, a square wave of neutron yield. The results to date are preliminary but quite promising. The system is capable of resolving the fissile material contained in a small fraction of the fuel rods in a cold fuel assembly. It also appears to be quite resilient to background neutron interference. The interrogating neutrons appear to be nonthermal and penetrating. Although a significant amount of work remains to fully explore the relevant physics and optimize the instrument design, the underlying concept appears sound.

  14. Active evacuation guidance using sensor agent robot

    Science.gov (United States)

    Ise, Daiki; Mita, Akira

    2012-04-01

    Evacuation systems for buildings are designed based on event scenarios, so they are not prepared for unexpected events that are not included in the scenarios. In this paper, we propose a new active evacuation guidance system using sensor agent robots. We first introduce a Structural Health Monitoring (SHM) system to be used in conjunction with sensor agent robots for active evacuation guidance. Then the role of sensor agent robots is explained. An algorithm to immediately access the safety of the building after a large earthquake is also proposed using only the information taken by a sensor agent robot.

  15. Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

    Science.gov (United States)

    Davis, John R.; Brubaker, Erik; Vetter, Kai

    2017-06-01

    In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. The expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate. Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. Three areas analyzed in San Francisco, Downtown Oakland, and Berkeley all demonstrated a suppression in the background rate of over 50% for the range of sky-view factors measured. This effect, which is due to the shielding of cosmic-ray produced neutrons by surrounding buildings, was comparable to the pressure influence which yielded a 32% suppression in the count rate over the range of pressures measured.

  16. Progress in neutron activation analysis for uranium

    Institute of Scientific and Technical Information of China (English)

    杜鸿善; 李贵群; 董桂芝; 李俊兰; K.H.Chiu; C.M.Wai

    1996-01-01

    A new type of extractant, sym-dibenzo-16-crown-5-oxyhydroxamic acid (HL) is introduced. The extractions of UO22+, Na+, K+, Sr2+, Ba2+ and Br- were studied with HL in chloroform. The results obtained show that UO22+ can be quantitatively extracted at pH values above 5, whereas the extractions of K+, Na+, Sr2+, Ba2+ and Br- are negligible in the pH range of 2 - 7. The dependence of the distribution ratio of U(VI) on both the concentration of the HL and pH are linear, and they have the same slope of 2. This suggests that U(VI) appears to form a 1:2 complex with ligand. Uranium(VI) can be selectively separated and concentrated from interfering elements such as Na, K, Sr and Br by solvent extraction with HL under specific conditions. The recovery of uranium is nearly 100% and the radionudear purity of uranium is greater than 99.99%. Therefore, neutron activation analysis has greatly improved the sensitivity and accuracy for the detection of trace uranium from seawater.

  17. Measurements of DT and DD neutron yields by neutron activation on TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, C.W.; Larson, A.R. [Los Alamos National Lab., NM (United States); LeMunyan, G. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Loughlin, M.J. [JET Joint Undertaking, Abingdon (United Kingdom)

    1995-03-01

    A variety of elemental foils have been activated by neutron fluence from TFTR under conditions with the DT neutron yield per shot ranging from 10{sup 12} to over 10{sup 18}, and with the DT/(DD+DT) neutron ratio varying from 0.5% (from triton burnup) to unity. Linear response over this large dynamic range is obtained by reducing the mass of the foils and increasing the cooling time, all while accepting greatly improved counting statistics. Effects on background gamma-ray lines from foil-capsule-material contaminants, and the resulting lower limits on activation foil mass, have been determined. DT neutron yields from dosimetry standard reactions on aluminum, chromium, iron, nickel, zirconium, and indium are in agreement within the {+-}9% (one-sigma) accuracy of the measurements; also agreeing are yields from silicon foils using the ACTL library cross-section, while the ENDF/B-V library has too low a cross-section. Preliminary results from a variety of other threshold reactions are presented. Use of the {sup 115}In(n.n{prime}) {sup 115m}In reaction (0.42 times as sensitive to DT neutrons as DD neutrons) in conjunction with pure-DT reactions allows a determination of the DT/(DD+DT) ratio in trace tritium or low-power tritium beam experiments.

  18. Soil water content determination with cosmic-ray neutron sensor: Correcting aboveground hydrogen effects with thermal/fast neutron ratio

    Science.gov (United States)

    Tian, Zhengchao; Li, Zizhong; Liu, Gang; Li, Baoguo; Ren, Tusheng

    2016-09-01

    The cosmic-ray neutron sensor (CRNS), which estimates field scale soil water content, bridges the gap between point measurement and remote sensing. The accuracy of CRNS measurements, however, is affected by additional hydrogen pools (e.g., vegetation, snow, and rainfall interception). The objectives of this study are to: (i) evaluate the accuracy of CRNS estimates in a farmland system using depth and horizontal weighted point measurements, (ii) introduce a novel method for estimating the amounts of hydrogen from biomass and snow cover in CRNS data, and (iii) propose a simple approach for correcting the influences of aboveground hydrogen pool (expressed as aboveground water equivalent, AWE) on CRNS measurements. A field experiment was conducted in northeast China to compare soil water content results from CRNS to in-situ data with time domain reflectometry (TDR) and neutron probe (NP) in the 0-40 cm soil layers. The biomass water equivalent (BWE) and snow water equivalent (SWE) were observed to have separate linear relationships with the thermal/fast neutron ratio, and the dynamics of BWE and SWE were estimated correctly in the crop seasons and snow-covered seasons, respectively. A simple approach, which considered the AWE, AWE at calibration, and the effective measurement depth of CRNS, was introduced to correct the errors caused by BWE and SWE. After correction, the correlation coefficients between soil water contents determined by CRNS and TDR were 0.79 and 0.77 during the 2014 and 2015 crop seasons, respectively, and CRNS measurements had RMSEs of 0.028, 0.030, and 0.039 m3 m-3 in the 2014 and 2015 crop seasons and the snow-covered seasons, respectively. The experimental results also indicated that the accuracies of CRNS estimated BWE and SWE were affected by the distributions of aboveground hydrogen pools, which were related to the height of the CRNS device above ground surface.

  19. Intruder Activity Analysis under Unreliable Sensor Networks

    Energy Technology Data Exchange (ETDEWEB)

    Tae-Sic Yoo; Humberto E. Garcia

    2007-09-01

    This paper addresses the problem of counting intruder activities within a monitored domain by a sensor network. The deployed sensors are unreliable. We characterize imperfect sensors with misdetection and false-alarm probabilities. We model intruder activities with Markov Chains. A set of Hidden Markov Models (HMM) models the imperfect sensors and intruder activities to be monitored. A novel sequential change detection/isolation algorithm is developed to detect and isolate a change from an HMM representing no intruder activity to another HMM representing some intruder activities. Procedures for estimating the entry time and the trace of intruder activities are developed. A domain monitoring example is given to illustrate the presented concepts and computational procedures.

  20. Planetary Geochemistry Using Active Neutron and Gamma Ray Instrumentation

    Science.gov (United States)

    Parsons, A.; Bodnarik, J.; Evans, L.; Floyd, S.; Lim, L.; McClanahan, T.; Namkung, M.; Schweitzer, J.; Starr, R.; Trombka, J.

    2010-01-01

    The Pulsed Neutron Generator-Gamma Ray And Neutron Detector (PNG-GRAND) experiment is an innovative application of the active neutron-gamma ray technology so successfully used in oil field well logging and mineral exploration on Earth, The objective of our active neutron-gamma ray technology program at NASA Goddard Space Flight Center (NASA/GSFC) is to bring the PNG-GRAND instrument to the point where it can be flown on a variety of surface lander or rover missions to the Moon, Mars, Venus, asterOIds, comets and the satellites of the outer planets, Gamma-Ray Spectrometers have been incorporated into numerous orbital planetary science missions and, especially in the case of Mars Odyssey, have contributed detailed maps of the elemental composition over the entire surface of Mars, Neutron detectors have also been placed onboard orbital missions such as the Lunar Reconnaissance Orbiter and Lunar Prospector to measure the hydrogen content of the surface of the moon, The DAN in situ experiment on the Mars Science Laboratory not only includes neutron detectors, but also has its own neutron generator, However, no one has ever combined the three into one instrument PNG-GRAND combines a pulsed neutron generator (PNG) with gamma ray and neutron detectors to produce a landed instrument that can determine subsurface elemental composition without drilling. We are testing PNG-GRAND at a unique outdoor neutron instrumentation test facility recently constructed at NASA/GSFC that consists of a 2 m x 2 m x 1 m granite structure in an empty field, We will present data from the operation of PNG-GRAND in various experimental configurations on a known sample in a geometry that is identical to that which can be achieved on a planetary surface. We will also compare the material composition results inferred from our experiments to both an independent laboratory elemental composition analysis and MCNPX computer modeling results,

  1. Soil profile water content determination:Spatiotemporal variability of electromagnetic and neutron probe sensors in access tubes

    Science.gov (United States)

    Since the late 1980s, electromagnetic (EM) sensors for determination on of soil water content from within nonmetallic access tubes have been marketed as replacements for the neutron moisture meter (NMM); however, the accuracy, variability and physical significance of EM sensor field measurements hav...

  2. Neutron threshold activation detectors (TAD) for the detection of fissions

    Science.gov (United States)

    Gozani, Tsahi; Stevenson, John; King, Michael J.

    2011-10-01

    Prompt fission neutrons are one of the strongest signatures of the fission process. Depending on the fission inducing radiation, their average number ranges from 2.5 to 4 neutrons per fission. They are more energetic and abundant, by about 2 orders of magnitude, than the delayed neutrons (≈3 vs. ≈0.01) that are commonly used as indicators for the presence of fissionable materials. The detection of fission prompt neutrons, however, has to be done in the presence of extremely intense probing radiation that stimulated them. During irradiation, the fission stimulation radiation, X-rays or neutrons, overwhelms the neutron detectors and temporarily incapacitate them. Consequently, by the time the detectors recover from the source radiation, fission prompt neutrons are no longer emitted. In order to measure the prompt fission signatures under these circumstances, special measures are usually taken with the detectors such as heavy shielding with collimation, use of inefficient geometries, high pulse height bias and gamma-neutron separation via pulse-shape discrimination with an appropriate organic scintillator. These attempts to shield the detector from the flash of radiation result in a major loss of sensitivity. It can lead to a complete inability to detect the fission prompt neutrons. In order to overcome the blinding induced background from the source radiation, the detection of prompt fission neutrons needs to occur long after the fission event and after the detector has fully recovered from the source overload. A new approach to achieve this is to detect the delayed activation induced by the fission neutrons. The approach demonstrates a good sensitivity in adverse overload situations (gamma and neutron "flash") where fission prompt neutrons could normally not be detected. The new approach achieves the required temporal separation between the detection of prompt neutrons and the detector overload by the neutron activation of the detector material. The technique

  3. In vivo neutron activation facility at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ma, R.; Yasumura, Seiichi; Dilmanian, F.A.

    1997-11-01

    Seven important body elements, C, N, Ca, P, K, Na, and Cl, can be measured with great precision and accuracy in the in vivo neutron activation facilities at Brookhaven National Laboratory. The facilities include the delayed-gamma neutron activation, the prompt-gamma neutron activation, and the inelastic neutron scattering systems. In conjunction with measurements of total body water by the tritiated-water dilution method several body compartments can be defined from the contents of these elements, also with high precision. In particular, body fat mass is derived from total body carbon together with total body calcium and nitrogen; body protein mass is derived from total body nitrogen; extracellular fluid volume is derived from total body sodium and chlorine; lean body mass and body cell mass are derived from total body potassium; and, skeletal mass is derived from total body calcium. Thus, we suggest that neutron activation analysis may be valuable for calibrating some of the instruments routinely used in clinical studies of body composition. The instruments that would benefit from absolute calibration against neutron activation analysis are bioelectric impedance analysis, infrared interactance, transmission ultrasound, and dual energy x-ray/photon absorptiometry.

  4. Physical Activity Recognition from Smartphone Embedded Sensors

    DEFF Research Database (Denmark)

    Prudêncio, João; Aguiar, Ana; Roetter, Daniel Enrique Lucani

    2013-01-01

    The ubiquity of smartphones has motivated efforts to use the embedded sensors to detect various aspects of user context to transparently provide personalized and contextualized services to the user. One relevant piece of context is the physical activity of the smartphone user. In this paper, we...... propose a novel set of features for distinguishing five physical activities using only sensors embedded in the smartphone. Specifically, we introduce features that are normalized using the orientation sensor such that horizontal and vertical movements are explicitly computed. We evaluate a neural network...

  5. Physical Activity Recognition from Smartphone Embedded Sensors

    DEFF Research Database (Denmark)

    Prudêncio, João; Aguiar, Ana; Roetter, Daniel Enrique Lucani

    2013-01-01

    The ubiquity of smartphones has motivated efforts to use the embedded sensors to detect various aspects of user context to transparently provide personalized and contextualized services to the user. One relevant piece of context is the physical activity of the smartphone user. In this paper, we...... propose a novel set of features for distinguishing five physical activities using only sensors embedded in the smartphone. Specifically, we introduce features that are normalized using the orientation sensor such that horizontal and vertical movements are explicitly computed. We evaluate a neural network...

  6. Survey of Neutron Generators for Active Interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Calvin Elroy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, William L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sundby, Gary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chichester, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Johnson, James P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-05-02

    Some of these commercially available generators meet all of the requirements in Table 1, but there are other concerns. Most generators containing SF6 will be required to have the SF6 gas removed for shipping because of DOT regulations. However, Thermo Fisher has a DOT exemption. The P211 and B211 from Thermo Fisher meet the requirements listed in Table 1, but they are old designs and are no longer offered for sale. Also, they require 15 minutes or more of warmup before neutron output is available, and they lack a modern digital control. The nGen-300C from Starfire Industries is interesting because it is a portable system, but it uses the DD reaction for 2.5 MeV neutrons, which are not as penetrating as the 14 MeV neutrons from the DT reaction. The MP 320 from Thermo Fisher is another portable system, but the minimum pulse rate is 250 Hz, which is too fast for measurement of delayed neutrons and re-interrogation by delayed neutrons between pulses. The Genie 16 from Sodern (from France) probably meets the requirements, but the required power is probably too high for battery operation. The generators from Russia and China may be difficult to purchase, and service may not be available. The power required by some of these generators is low enough that batteries can be used. The portable units, nGen-300C and the MP320, could easily be operated with batteries. Other generators with low power requirements, as specified in the above vendors list, could possibly be operated with reason size batteries. The batteries do not need to be internal to the generator, but can be in a separate package. The availability of high capacity lithium batteries with sophisticated safety circuits makes battery operation more possible now than when lead acid batteries were used. The best path forward probably requires working with vendors of the existing systems. If Starfire Industries could be persuaded to put tritium in their nGen-300C generator, possibly in collaboration with a national

  7. Background by neutron activation in GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Meierhofer, Georg; Dietrich, Dennis; Freund, Kai; Grabmayr, Peter; Hegai, Alexander; Jochum, Josef; Knapp, Markus; Ritter, Florian [Kepler Center for Astro and Particle Physics, Universitaet Tuebingen (Germany); Canella, Lea [Institut fuer Radiochemie, Technische Universitaet Muenchen (Germany); Jolie, Jan [Institut fuer Kernphysik, Universitaet zu Koeln (Germany); Kudejova, Petra [FRM II, Technische Universitaet Muenchen (Germany)

    2010-07-01

    The observation of the neutrinoless double beta decay is a proof of the Majorana nature of the neutrino. The long half-life of this decay requires experiments of very low background rates in the region of interest at Q{sub {beta}}{sub {beta}}. Prompt {gamma}-rays after neutron capture on germanium and the {beta}-decay of {sup 77}Ge contribute to the background in experiments using {sup 76}Ge for the search of the neutrinoless double beta decay. The poorly known prompt {gamma}-ray spectra and the neutron capture cross sections for the (n,{gamma}) reactions of {sup 74}Ge and {sup 76}Ge were measured at the research reactor FRM II (Munich). The obtained data are needed in MC simulations for qualitative and quantitative background prediction in the Gerda experiment. The data and their implication on the background in Gerda are presented.

  8. Analysis of natural neutron flux in a seismically active zone

    Directory of Open Access Journals (Sweden)

    V. F. Ostapenko

    2003-01-01

    Full Text Available In a seismically active zone in the near Almaty area (Kazakhstan since 1996 observations of variations of a natural neutron flux have been conducted. Sometimes the neutron flux rises sharply within the one-hour interval in comparison with the background. It occurs on the eve of activation of seismic processes. Increase of the neutron flux level had taken place from 1 h to 10 days prior to earthquakes. It is also indicated a tendency of growth of the anomaly level in accordance with the growth of energetic class of the subsequent earthquake. A character of connection between the neutron flux and earthquakes is still not clear. It is proposed that the neutron flux anomalies caused by variations of cosmic radiation intensity under action of fluxes of solar material, which is burst into interplanetary space (solar wind during solar flares. Energy of the solar wind transferred to Earth puts into action a trigger mechanism of the process of initiation of earthquakes at those places where conditions have already been prepared for them. The neutron flux anomalies can be used as substantial additional information for classical geophysical methods of short-term earthquake prediction.

  9. Quantitative neutron capture resonance analysis verified with instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Blaauw, M. E-mail: blaauw@iri.tudelft.nl; Postma, H.; Mutti, P

    2003-06-01

    The newly developed elemental analysis technique Neutron Resonance Capture Analysis (NRCA) was verified by analyzing a prehistoric bronze arrowhead with both NRCA and Instrumental Activation Analysis (INAA). In NRCA, elements are identified through their neutron resonance capture energies as determined through detection of prompt capture gamma-rays as a function of time of flight. The quantification is obtained from the resonance peak areas. Corrections are required for neutron-energy-dependent dead time and self-shielding, the latter also depending on Doppler broadening. The analysis program REFIT, of which the intended use is the determination of the resonance parameters, was used to this end. The agreement observed between INAA and NRCA results indicates that the NRCA results obtained are accurate.

  10. A High Temperature-Tolerant and Radiation-Resistant In-Core Neutron Sensor for Advanced Reactors. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Lei [The Ohio State Univ., Columbus, OH (United States); Miller, Don [The Ohio State Univ., Columbus, OH (United States)

    2015-01-23

    The objectives of this project are to develop a small and reliable gallium nitride (GaN) neutron sensor that is capable of withstanding high neutron fluence and high temperature, isolating gamma background, and operating in a wide dynamic range. The first objective will be the understanding of the fundamental materials properties and electronic response of a GaN semiconductor materials and device in an environment of high temperature and intense neutron field. To achieve such goal, an in-situ study of electronic properties of GaN device such as I-V, leakage current, and charge collection efficiency (CCE) in high temperature using an external neutron beam will be designed and implemented. We will also perform in-core irradiation of GaN up to the highest yet fast neutron fluence and an off-line performance evaluation.

  11. Neutron-activation revisited: the depletion and depletion-activation models.

    Science.gov (United States)

    Abdel-Rahman, Wamied; Podgorsak, Ervin B

    2005-02-01

    The growth of a radioactive daughter in neutron activation is commonly described with the saturation model that ignores the consumption of parent nuclei during the radio-activation process. This approach is not valid when radioactive sources with high specific activities are produced or when the particle fluence rates used are very high. Assuming a constant neutron fluence rate throughout the activation target, a neutron-activation model that accounts for the depletion in parent nuclei is introduced. This depletion model is governed by relationships similar to those describing the parent-daughter-granddaughter decay series, and, in contrast to the saturation model, correctly predicts the practical limit of the daughter specific activity, irrespective of the particle fluence rate. Also introduced is a neutron-activation model that in addition to parent depletion accounts for the neutron activation of daughter nuclei in situations where the cross section for this effect is high. The model is referred to as the depletion-activation model and it provides the most realistic description for the daughter specific activity in neutron activation. Three specific neutron activation examples of interest to medical physics are presented: activation of molybdenum-98 into molybdenum-99 described by the saturation model; activation of cobalt-59 into cobalt-60 described by the depletion model; and activation of iridium-191 into iridium-192 described by the depletion-activation model.

  12. Intercomparison of Neutron Beam Guides for Cold Neutron Activation Station at HANARO using McStas/VITESS/RESTRAX Codes

    Energy Technology Data Exchange (ETDEWEB)

    Tuan, Hoang Sy Minh; Sun, Gwang Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    The HANARO (KAERI) research reactor has been developed a neutron guide system for cold neutron (CN) research facilities since July, 2003. The neutron guide system plays an important role in transporting cold neutrons from the CN source to the neutron facilities as CN-NDP, CN-PGAA, SANS, etc. The CN activation station is being installed in the HANARO cold-neutron research project. The CN-NDP and CN-PGAA were selected as two facilities using at this station. At the end position of CG1 and CG2B beam guides, the CN-NDP and CN-PGAA will be installed in the CN guide hall. In order to predict the neutron flux and intensity values at the CG1 and CG2B beam guides, the simulation results of neutron flux at the CG1 and CG2B beam guides are presented by using several Monte Carlo (MC) neutron ray-tracing simulation codes. The intercomparison of neutron flux values between McStas, VITESS and RESTRAX are performed for getting fairly correct results at two neutron beam guides

  13. Development of SERS active fibre sensors

    CERN Document Server

    Polwart, E

    2002-01-01

    Surface-enhanced Raman scattering (SERS) is sensitive and selective and when coupled with fibre-optics could potentially produce an effective chemical sensing system. This thesis concerns the development of a single-fibre-based sensor, with an integral SERS-active substrate. A number of different methods for the manufacture of SERS-active surfaces on glass substrates were investigated and compared. The immobilisation of metal nanoparticles on glass functionalised with (3-aminopropyl)trimethoxysilane emerged as a suitable approach for the production of sensors. Substrates prepared by this approach were characterised using UV-visible spectroscopy, electron microscopy and Raman mapping. It was found that exposure of substrates to laser radiation led to a decrease in the signal recorded from adsorbed analytes. This speed of the decrease was shown to depend on the analyte, and the exciting wavelength and power. SERS-active fibre sensors were produced by immobilisation of silver nanoparticles at the distal end of a...

  14. Triton burnup measurements in KSTAR using a neutron activation system

    Science.gov (United States)

    Jo, Jungmin; Cheon, MunSeong; Kim, Jun Young; Rhee, T.; Kim, Junghee; Shi, Yue-Jiang; Isobe, M.; Ogawa, K.; Chung, Kyoung-Jae; Hwang, Y. S.

    2016-11-01

    Measurements of the time-integrated triton burnup for deuterium plasma in Korea Superconducting Tokamak Advanced Research (KSTAR) have been performed following the simultaneous detection of the d-d and d-t neutrons. The d-d neutrons were measured using a 3He proportional counter, fission chamber, and activated indium sample, whereas the d-t neutrons were detected using activated silicon and copper samples. The triton burnup ratio from KSTAR discharges is found to be in the range 0.01%-0.50% depending on the plasma conditions. The measured burnup ratio is compared with the prompt loss fraction of tritons calculated with the Lorentz orbit code and the classical slowing-down time. The burnup ratio is found to increase as plasma current and classical slowing-down time increase.

  15. Active Interrogation of Sensitive Nuclear Material Using Laser Driven Neutron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Favalli, Andrea [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Roth, Markus [Technische Universitaet, Darmstadt (Germany)

    2015-05-01

    An investigation of the viability of a laser-driven neutron source for active interrogation is reported. The need is for a fast, movable, operationally safe neutron source which is energy tunable and has high-intensity, directional neutron production. Reasons for the choice of neutrons and lasers are set forth. Results from the interrogation of an enriched U sample are shown.

  16. Neutron activation analysis: Modelling studies to improve the neutron flux of Americium–Beryllium source

    Directory of Open Access Journals (Sweden)

    Abdessamad Didi

    2017-06-01

    Full Text Available Americium–beryllium (Am-Be; n, γ is a neutron emitting source used in various research fields such as chemistry, physics, geology, archaeology, medicine, and environmental monitoring, as well as in the forensic sciences. It is a mobile source of neutron activity (20 Ci, yielding a small thermal neutron flux that is water moderated. The aim of this study is to develop a model to increase the neutron thermal flux of a source such as Am-Be. This study achieved multiple advantageous results: primarily, it will help us perform neutron activation analysis. Next, it will give us the opportunity to produce radio-elements with short half-lives. Am-Be single and multisource (5 sources experiments were performed within an irradiation facility with a paraffin moderator. The resulting models mainly increase the thermal neutron flux compared to the traditional method with water moderator.

  17. Current status of neutron activation analysis in HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Moon, Jong Hwa; Sohn, Jae Min [Korea Atomic Energy Research Institute, Daejeon (Korea)

    2003-03-01

    The facilities for neutron activation analysis in the HANARO (Hi-flux Advanced Neutron Application Research Reactor) are described and the main applications of NAA (Neutron Activation Analysis) are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system were installed at three irradiation holes of HANARO at the end of 1995. The performance of the NAA facility was examined to identify the characteristics of the tube transfer system, irradiation sites and custom-made polyethylene irradiation capsule. The available thermal neutron fluxes at irradiation sites are in the range of 3 x 10{sup 13} - 1 x 10{sup 14} n/cm{sup 2}{center_dot}s and cadmium ratios are in 15 - 250. For an automatic sample changer for gamma-ray counting, a domestic product was designed and manufactured. An integrated computer program (Labview) to analyse the content was developed. In 2001, PGNAA (Prompt Gamma Neutron Activation Analysis) facility has been installed using a diffracted neutron beam of ST1. NAA has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials, and various polymers for research and development. The improvement of analytical procedures and establishment of an analytical quality control and assurance system were studied. Applied research and development for the environment, industry and human health by NAA and its standardization were carried out. For the application of the KOLAS (Korea Laboratory Accreditation Scheme), evaluation of measurement uncertainty and proficiency testing of reference materials were performed. Also to verify the reliability and to validate analytical results, intercomparison studies between laboratories were carried out. (author)

  18. Performance of active edge pixel sensors

    Science.gov (United States)

    Bomben, M.; Ducourthial, A.; Bagolini, A.; Boscardin, M.; Bosisio, L.; Calderini, G.; D'Eramo, L.; Giacomini, G.; Marchiori, G.; Zorzi, N.; Rummler, A.; Weingarten, J.

    2017-05-01

    To cope with the High Luminosity LHC harsh conditions, the ATLAS inner tracker has to be upgraded to meet requirements in terms of radiation hardness, pile up and geometrical acceptance. The active edge technology allows to reduce the insensitive area at the border of the sensor thanks to an ion etched trench which avoids the crystal damage produced by the standard mechanical dicing process. Thin planar n-on-p pixel sensors with active edge have been designed and produced by LPNHE and FBK foundry. Two detector module prototypes, consisting of pixel sensors connected to FE-I4B readout chips, have been tested with beams at CERN and DESY. In this paper the performance of these modules are reported. In particular the lateral extension of the detection volume, beyond the pixel region, is investigated and the results show high hit efficiency also at the detector edge, even in presence of guard rings.

  19. Neutron Field Measurements in Phantom with Foil Activation Methods.

    Science.gov (United States)

    1986-11-29

    jI25 Ii III uumu ullli~ S....- - Lb - w * .qJ’ AD-A 192 122 ulJ. IL (pj DNA-TR-87- 10 N EUTRON FIELD MEASUREMENTS IN PHANTOM WITH FOIL ACTIVATION...SAND II Measurements in Phantom 6 4 The 5-Foil Neutron Dosimetry Method 29 5 Comparison of SAND II and Simple 5-Foil Dosimetry Method 34 6 Thermal ...quite reasonable. The monkey phantom spectrum differs from the NBS U-235 fission spectrum in that the former has a I/E tail plus thermal -neutron peak

  20. Status report of CPHS and neutron activities at Tsinghua University

    Science.gov (United States)

    Wang, X.; Xing, Q.; Zheng, S.; Yang, Y.; Gong, H.; Xiao, Y.; Wu, H.; Guan, X.; Du, T.

    2016-11-01

    The Compact Pulsed Hadron Source (CPHS) project that was launched in September 2009 at Tsinghua University has reached a first commissioning stage in conjunction with ongoing activities to fulfill the eventual design goal of a ˜ 1013 n/s epithermal-to-cold neutron yield for education, instrumentation development, and industrial applications. Here, we report the latest progress on the commissioning and applications of 3MeV proton and neutron beam lines in the last one and half years, and the design, fabrication, engineering of the 13MeV/16kW proton accelerator system.

  1. Active helium target: Neutron scalar polarizability extraction via Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Meg, E-mail: mmorris@mta.ca; Hornidge, David [Mount Allison University, Sackville, New Brunswick (Canada); Annand, John; Strandberg, Bruno [University of Glasgow, Scotland (United Kingdom)

    2015-12-31

    Precise measurement of the neutron scalar polarizabilities has been a lasting challenge because of the lack of a free-neutron target. Led by the University of Glasgow and the Mount Allison University groups of the A2 collaboration in Mainz, Germany, preparations have begun to test a recent theoretical model with an active helium target with the hope of determining these elusive quantities with small statistical, systematic, and model-dependent errors. Apparatus testing and background-event simulations have been carried out, with the full experiment projected to run in 2015. Once determined, these values can be applied to help understand quantum chromodynamics in the nonperturbative region.

  2. Progress in small angle neutron scattering activities in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Abdul Aziz Bin Mohamed; Azali Bin Muhamad; Shukri Bin Mohd [Malaysian Institute for Nuclear Technology Research (MINT), Bangi, Kajang (Malaysia)

    1999-10-01

    The current status of SANS (Small Angle Neutron Scattering facility) activities in Malaysia has been presented. Many works need to be done for system improvement before the system can be confidently used as one of effective quality control tools in materials production and engineering sectors. (author)

  3. Applied research of environmental monitoring using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Young Sam; Moon, Jong Hwa; Chung, Young Ju

    1997-08-01

    This technical report is written as a guide book for applied research of environmental monitoring using Instrumental Neutron Activation Analysis. The contents are as followings; sampling and sample preparation as a airborne particulate matter, analytical methodologies, data evaluation and interpretation, basic statistical methods of data analysis applied in environmental pollution studies. (author). 23 refs., 7 tabs., 9 figs.

  4. Instrumental Neutron Activation Analysis Technique using Subsecond Radionuclides

    DEFF Research Database (Denmark)

    Nielsen, H.K.; Schmidt, J.O.

    1987-01-01

    The fast irradiation facility Mach-1 installed at the Danish DR 3 reactor has been used in boron determinations by means of Instrumental Neutron Activation Analysis using12B with 20-ms half-life. The performance characteristics of the system are presented and boron determinations of NBS standard...

  5. Instrumental neutron activation analysis of some ayurvedic medicines: Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Rajurkar, N.S.; Vinchurkar, M.S. (Poona Univ., Pune (India). Dept. of Chemistry)

    1992-12-01

    Several medicines have been manufactured and prescribed to overcome mineral deficiencies in the human body. Such medicines are mixtures of several components. The present work is undertaken to analyze various Ayurvedic medicines, mainly of herbal origin and used for different purposes, for their elemental contents, by neutron activation analysis. (author).

  6. BNL ACTIVITIES IN ADVANCED NEUTRON SOURCE DEVELOPMENT: PAST AND PRESENT

    Energy Technology Data Exchange (ETDEWEB)

    HASTINGS,J.B.; LUDEWIG,H.; MONTANEZ,P.; TODOSOW,M.; SMITH,G.C.; LARESE,J.Z.

    1998-06-14

    Brookhaven National Laboratory has been involved in advanced neutron sources almost from its inception in 1947. These efforts have mainly focused on steady state reactors beginning with the construction of the first research reactor for neutron beams, the Brookhaven Graphite Research Reactor. This was followed by the High Flux Beam Reactor that has served as the design standard for all the subsequent high flux reactors constructed worldwide. In parallel with the reactor developments BNL has focused on the construction and use of high energy proton accelerators. The first machine to operate over 1 GeV in the world was the Cosmotron. The machine that followed this, the AGS, is still operating and is the highest intensity proton machine in the world and has nucleated an international collaboration investigating liquid metal targets for next generation pulsed spallation sources. Early work using the Cosmotron focused on spallation product studies for both light and heavy elements into the several GeV proton energy region. These original studies are still important today. In the sections below the authors discuss the facilities and activities at BNL focused on advanced neutron sources. BNL is involved in the proton source for the Spallation Neutron source, spectrometer development at LANSCE, target studies using the AGS and state-of-the-art neutron detector development.

  7. BNL Activities in Advanced Neutron Source Development: Past and Present

    Energy Technology Data Exchange (ETDEWEB)

    Hastings, J.B.; Ludewig, H.; Montanez, P.; Todosow, M.; Smith, G.C.; Larese, J.Z.

    1998-06-14

    Brookhaven National Laboratory has been involved in advanced neutron sources almost from its inception in 1947. These efforts have mainly focused on steady state reactors beginning with the construction of the first research reactor for neutron beams, the Brookhaven Graphite Research Reactor. This was followed by the High Flux Beam Reactor that has served as the design standard for all the subsequent high flux reactors constructed worldwide. In parallel with the reactor developments BNL has focused on the construction and use of high energy proton accelerators. The first machine to operate over 1 GeV in the world was the Cosmotron. The machine that followed this, the AGS, is still operating and is the highest intensity proton machine in the world and has nucleated an international collaboration investigating liquid metal targets for next generation pulsed spallation sources. Early work using the Cosmotron focused on spallation product studies for both light and heavy elements into the several GeV proton energy region. These original studies are still important today. In this report we discuss the facilities and activities at BNL focused on advanced neutron sources. BNL is involved in the proton source for the Spallation Neutron source, spectrometer development at LANSCE, target studies using the AGS and state-of-the-art neutron detector development.

  8. Active neutron spectrometry with superheated drop (bubble) detectors

    Energy Technology Data Exchange (ETDEWEB)

    d`Errico, F.; Curzio, G. [Pisa Univ. (Italy). Dipt. di Costruzioni Meccaniche e Nucleari]|[Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Alberts, W.G.; Guldbakke, S.; Kluge, H.; Matzke, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1995-12-31

    A new approach to neutron spectrometry has been developed in a joint project by DCMN Pisa and PTB Braunschweig. The system relies on the use of superheated drop (bubble) detectors and the thermodynamic control of their detection thresholds. This is the result of investigations into the physics of these detectors combined with extensive experimental work on their response to neutrons. These studies indicate that the higher the degree of superheat of a detector, the lower the minimum energy that secondary charged particles, and therefore primary neutrons, must impart to the droplets in order to nucleate their evaporation. Therefore, by controlling the temperature of the detectors, accurately defined detection thresholds, virtually any desired one, can be generated in the 0.01-10 MeV neutron energy range. An active prototype instrument has been developed: bubbles are counted acoustically and temperature regulation is achieved by means of thin heating strips. Tests with reference neutron spectra show that the system is suitable for few-channel spectrometry and may be useful for radiation protection dosimetry. Appropriate unfolding algorithms are currently investigated, to be ultimately implemented in an automatic device. (author).

  9. Prototyping an Active Neutron Veto for SuperCDMS

    Energy Technology Data Exchange (ETDEWEB)

    Calkins, Robert [Southern Methodist U.; Loer, Ben [Fermilab

    2015-08-17

    Neutrons, originating cosmogenically or from radioactive decays, can produce signals in dark matter detectors that are indistinguishable from Weakly Interacting Massive Particles (WIMPs). To combat this background for the SuperCDMS SNOLAB experiment, we are investigating designs for an active neutron veto within the constrained space of the compact SuperCDMS passive shielding. The current design employs an organic liquid scintillator mixed with an agent to enhance thermal neutron captures, with the scintillation light collected using wavelength-shifting fibers and read out by silicon photo-multipliers. We will describe the proposed veto and its predicted efficiency in detail and give some recent results from our R&D and prototyping efforts.

  10. Prototyping an active neutron veto for SuperCDMS

    Science.gov (United States)

    Calkins, Robert; Loer, Ben

    2015-08-01

    Neutrons, originating cosmogenically or from radioactive decays, can produce signals in dark matter detectors that are indistinguishable from Weakly Interacting Massive Particles (WIMPs). To combat this background for the SuperCDMS SNOLAB experiment, we are investigating designs for an active neutron veto within the constrained space of the compact SuperCDMS passive shielding. The current design employs an organic liquid scintillator mixed with an agent to enhance thermal neutron captures, with the scintillation light collected using wavelength-shifting fibers and read out by silicon photo-multipliers. We will describe the proposed veto and its predicted efficiency in detail and give some recent results from our R&D and prototyping efforts.

  11. Prototyping an Active Neutron Veto for SuperCDMS

    CERN Document Server

    Calkins, Robert

    2015-01-01

    Neutrons, originating cosmogenically or from radioactive decays, can produce signals in dark matter detectors that are indistinguishable from Weakly Interacting Massive Particles (WIMPs). To combat this background for the SuperCDMS SNOLAB experiment, we are investigating designs for an active neutron veto within the constrained space of the compact SuperCDMS passive shielding. The current design employs an organic liquid scintillator mixed with an agent to enhance thermal neutron captures, with the scintillation light collected using wavelength-shifting fibers and read out by silicon photo-multipliers. We will describe the proposed veto and its predicted efficiency in detail and give some recent results from our R&D and prototyping efforts.

  12. Adaptive Sensor Activity Scheduling in Distributed Sensor Networks: A Statistical Mechanics Approach

    OpenAIRE

    Abhishek Srivastav; Asok Ray; Shashi Phoha

    2009-01-01

    This article presents an algorithm for adaptive sensor activity scheduling (A-SAS) in distributed sensor networks to enable detection and dynamic footprint tracking of spatial-temporal events. The sensor network is modeled as a Markov random field on a graph, where concepts of Statistical Mechanics are employed to stochastically activate the sensor nodes. Using an Ising-like formulation, the sleep and wake modes of a sensor node are modeled as spins with ferromagnetic neighborhood interaction...

  13. An improved prompt gamma neutron activation analysis facility using a focused diffracted neutron beam

    Science.gov (United States)

    Riley, Kent J.; Harling, Otto K.

    1998-09-01

    The performance of the prompt gamma neutron activation analysis (PGNAA) facility at the MIT Research Reactor has been improved by a series of modifications. These modifications have increased the flux by a factor of three at the sample position to 1.7 × 10 7 n/cm 2 s, and have increased the sensitivity, on average, by a factor of 2.5. The background for many samples of interest is dominated by unavoidable neutron interactions that occur in or near the sample. Other background components comprise only 20% of the total background count rate. The implementation of fast electronics has helped to keep dead time reasonable, in spite of the increased count rates. The PGNAA facility at the MIT Research Reactor continues to serve as a major analytical tool for quantifying 10B in biological samples for Boron Neutron Capture Therapy (BNCT) research. The sensitivity for boron-10 in water is 18 750 cps/mg. The sensitivity for pure elements suitable for PGNAA analysis is reported. Possible further improvements are discussed.

  14. Some Applications of Fast Neutron Activation Analysis of Oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Owrang, Farshid

    2003-07-01

    In this thesis we focus on applications of neutron activation of oxygen for several purposes: A) measuring the water level in a laboratory tank, B) measuring the water flow in a pipe system set-up, C) analysing the oxygen in combustion products formed in a modern gasoline SI engine, and D) measuring on-line the amount of oxygen in bulk liquids. A) Water level measurements. The purpose of this work was to perform radiation based water level measurements, aimed at nuclear reactor vessels, on a laboratory scale. A laboratory water tank was irradiated by fast neutrons from a neutron generator. The water was activated at different water levels and the water level was decreased. The produced gamma radiation was measured using two detectors at different heights. The results showed that the method is suitable for measurement of water level and that a relatively small experimental set-up can be used for developing methods for water level measurements in real boiling water reactors based on activated oxygen in the water. B) Water flows in pipe. The goal in this work was to investigate the asymmetric distribution of activity in flow measurements with pulsed neutron activation (PNA) in a laboratory piping system. Earlier investigations had shown a discrepancy between the measured velocity of the activated water by PNA and the true mean velocity in the pipe. This discrepancy decreased with larger distances from the activation point. It was speculated that the induced activity in the pipe did not distribute homogeneously. With inhomogeneous radial distribution of activity in combination with a velocity profile in the pipe, the activated water may not have the same velocity as the mean velocity of water in the pipe. To study this phenomenon, a water-soluble colour was injected into a transparent pipe for simulation of the transport of the activated water. The radial concentration of the colour, at different distances from the activation point, was determined. The result

  15. Neutron activation analysis applied to nutritional and foodstuff studies

    Energy Technology Data Exchange (ETDEWEB)

    Maihara, Vera A.; Santos, Paola S.; Moura, Patricia L.C.; Castro, Lilian P. de, E-mail: vmaihara@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Avegliano, Roseane P., E-mail: pagliaro@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Coordenadoria de Assistencia Social. Div. de Alimentacao

    2009-07-01

    Neutron Activation Analysis, NAA, has been successfully used on a regularly basis in several areas of nutrition and foodstuffs. NAA has become an important and useful research tool due to the methodology's advantages. These include high accuracy, small quantities of samples and no chemical treatment. This technique allows the determination of important elements directly related to human health. NAA also provides data concerning essential and toxic concentrations in foodstuffs and specific diets. In this paper some studies in the area of nutrition which have been carried out at the Neutron Activation Laboratory of IPEN/CNEN-SP will be presented: a Brazilian total diet study: nutritional element dietary intakes of Sao Paulo state population; a study of trace element in maternal milk and the determination of essential trace elements in some edible mushrooms. (author)

  16. Application of neutron activation tracer sediment technique on environmental science

    Institute of Scientific and Technical Information of China (English)

    YinYi; ZhongWei-Ni; 等

    1997-01-01

    Field and laboratory inverstigations were carried out to study the transport and dispersion law of polluted sediments near wastewater outlet using neutron activation tracer technique.The direction of transport and dispersion of polluted sediments,dispersion amount in different directions,sedimentary region of polluted sediment and evaluation of polluted risk are given.This provided a new test method for the study of environmental science and added a new forecasted content for the evaluation of environmental influence.

  17. Characterization of Phoenician pottery from Mothia by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cesana, A.; Terrani, M. (Politecnico di Milano (Italy). Centro Studi Nucleari E. Fermi); Ciasca, A. (Rome Univ. (Italy)); Cuomo di Caprio, N. (Venice Univ. (Italy)); Tusa, V. (Soprintendenza Archeologica della Sicilia Occidentale, Palermo (Italy))

    1983-01-01

    The concentration of 7 elements (Na, Al, Mg, Ti, Ca, V, Mn) was determined by neutron activation analysis in 35 samples of pottery and 14 samples of clay. The samples were collected in ancient Mothia (Sicily) and in its neighbourhoods. Cluster analysis of the data showed that most of the samples are homogeneous and confirmed the archaeological evidence that they are mostly local ware. The detailed results of the analyses are reported and the technique used for cluster analysis is described.

  18. Diagnostic Application of Absolute Neutron Activation Analysis in Hematology

    Energy Technology Data Exchange (ETDEWEB)

    Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.

    2004-10-03

    The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.

  19. Obsidian sources characterized by neutron-activation analysis.

    Science.gov (United States)

    Gordus, A A; Wright, G A; Griffin, J B

    1968-07-26

    Concentrations of elements such as manganese, scandium, lanthanum, rubidium, samarium, barium, and zirconium in obsidian samples from different flows show ranges of 1000 percent or more, whereas the variation in element content in obsidian samples from a single flow appears to be less than 40 percent. Neutron-activation analysis of these elements, as well as of sodium and iron, provides a means of identifying the geologic source of an archeological artifact of obsidian.

  20. {sup 4}H-SiC neutron sensors based on ion implanted {sup 10}B neutron converter layer

    Energy Technology Data Exchange (ETDEWEB)

    Issa, F.; Ottaviani, L.; Vervisch, V.; Ferone, R.; Palais, O. [Universite Aix-Marseille, Marseille 13397, (France); Szalkai, D.; Klix, A. [Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology, Karlsruhe 76344, (Germany); Vermeeren, L. [SCK-CEN, B-2400 Mol, (Belgium); Lyoussi, A. [Laboratoire Dosimetrie Capteurs Instrumentation, CEA, Cadarache 13108, (France); Kuznetsov, A. [University of Oslo, NO-0316 Oslo, (Norway); Lazar, M. [AMPERE, UMR 500, INSA de Lyon, 69621 Villeurbanne, (France); Hallen, A. [KTH, Electrum 229, 16440 Kista, (Sweden)

    2015-07-01

    In the framework of the I{sub S}MART project the main aim is to develop an innovative complete radiation detection system based on silicon carbide technology in view to detect neutrons (thermal and fast) and photons for harsh environments. In the present work two geometries have been realized based on ion implantation of boron. In the first geometry, {sup 10}B ions have been implanted into the Al metallic contact to create the neutron converter layer. In the second geometry one single process has been used to realize both the p+-layer and the neutron converter layer. The technological processes followed to fabricate these detectors, with a study of their electrical behavior and their responses under thermal neutron irradiations are addressed in this paper. (authors)

  1. NEUTRON ACTIVATION ANALYSIS APPLICATIONS AT THE SAVANNAH RIVER SITE USING AN ISOTOPIC NEUTRON SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Diprete, D; C Diprete, C; Raymond Sigg, R

    2006-08-14

    NAA using {sup 252}Cf is used to address important areas of applied interest at SRS. Sensitivity needs for many of the applications are not severe; analyses are accomplished using a 21 mg {sup 252}Cf NAA facility. Because NAA allows analysis of bulk samples, it offers strong advantages for samples in difficult-to-digest matrices when its sensitivity is sufficient. Following radiochemical separation with stable carrier addition, chemical yields for a number methods are determined by neutron activation of the stable carrier. In some of the cases where no suitable stable carriers exist, the source has been used to generate radioactive tracers to yield separations.

  2. Diagnosis of mucoviscidosis by neutron activation analysis. Part 1; Diagnostico da mucoviscidose utilizando analise por ativacao com neutrons. Parte 1

    Energy Technology Data Exchange (ETDEWEB)

    Bellido, Luis F.; Bellido, Alfredo V

    1997-02-01

    Symptoms pathology, incidence, and gravity of the inherent syndrome called mucoviscidosis, or cystic fibrosis are described in this Part I. The analytical methods used for its diagnosis, both the conventional chemical ones and by neutron activation analysis are also summarised. Finally, an analytical method to study the incidence of mucoviscidosis in Brazil is presented. This , essentially, consists in bromine determination, in fingernails, by resonance neutron activation analysis. (author) 33 refs., 13 figs.

  3. Radioactive waste caracterisation by neutron activation

    OpenAIRE

    Nicol, Tangi

    2016-01-01

    Nuclear activities produce radioactive wastes classified following their radioactive level and decay time. An accurate characterization is necessary for efficient classification and management. Medium and high level wastes containing long lived radioactive isotopes will be stored in deep geological storage for hundreds of thousands years. At the end of this period, it is essential to ensure that the wastes do not represent any risk for humans and environment, not only from radioactive point o...

  4. Provenience studies using neutron activation analysis: the role of standardization

    Energy Technology Data Exchange (ETDEWEB)

    Harbottle, G

    1980-01-01

    This paper covers the historical background of chemical analysis of archaeological artifacts which dates back to 1790 to the first application of neutron activation analysis to archaeological ceramics and goes on to elaborate on the present day status of neutron activation analysis in provenience studies, and the role of standardization. In principle, the concentrations of elements in a neutron-activated specimen can be calculated from an exact knowledge of neutron flux, its intensity, duration and spectral (energy) distribution, plus an exact gamma ray count calibrated for efficiency, corrected for branching rates, etc. However, in practice it is far easier to compare one's unknown to a standard of known or assumed composition. The practice has been for different laboratories to use different standards. With analyses being run in the thousands throughout the world, a great benefit would be derived if analyses could be exchanged among all users and/or generators of data. The emphasis of this paper is on interlaboratory comparability of ceramic data; how far are we from it, what has been proposed in the past to achieve this goal, and what is being proposed. All of this may be summarized under the general heading of Analytical Quality Control - i.e., how to achieve precise and accurate analysis. The author proposes that anyone wishing to analyze archaeological ceramics should simply use his own standard, but attempt to calibrate that standard as nearly as possible to absolute (i.e., accurate) concentration values. The relationship of Analytical Quality Control to provenience location is also examined.

  5. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    Science.gov (United States)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-11-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×108 cm-2 s-1 to 1014 cm-2 s-1. The 202Hg(n,γ)203Hg nuclear reaction was used for mercury mass evaluation. Activities of 203Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg2Cl2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps.

  6. Neutron shielding and activation of the MASTU device and surrounds

    CERN Document Server

    Taylor, David; Turner, Andrew; Davis, Andrew

    2014-01-01

    A significant functional upgrade is planned for the Mega Ampere Spherical Tokamak (MAST) device, located at Culham in the UK, including the implementation of a notably greater neutral beam injection power. This upgrade will cause the emission of a substantially increased intensity of neutron radiation for a substantially increased amount of time upon operation of the device. Existing shielding and activation precautions are shown to prove insufficient in some regards, and recommendations for improvements are made, including the following areas: shielding doors to MAST shielded facility enclosure (known as "the blockhouse"); north access tunnel; blockhouse roof; west cabling duct. In addition, some specific neutronic dose rate questions are addressed and answered; those discussed here relate to shielding penetrations and dose rate reflected from the air above the device ("skyshine").

  7. Evaluation of a cosmic-ray neutron sensor network for improved land surface model prediction

    Science.gov (United States)

    Baatz, Roland; Hendricks Franssen, Harrie-Jan; Han, Xujun; Hoar, Tim; Bogena, Heye; Vereecken, Harry

    2017-04-01

    Land surface models describe biogeophysical and biogeochemical processes at the land surface, and represent the lower boundary condition of atmospheric circulation models. Their key role is the quantification of mass and energy fluxes between the land surface and the atmosphere. Predictions with land surface models are affected by many unknown parameters, uncertain meteorological forcings and incomplete process understanding. Measurement data (e.g., soil moisture) can help to improve land surface model predictions. However, soil moisture products obtained from satellite remote sensing are normally available at a very coarse resolution and give information on the upper few centimetres of the soil only. Therefore, the recently developed Cosmic Ray Neutron Sensors (CRNS) are of high interest for predictions by land surface models, because they measure neutron count intensity, which is related to integral soil moisture content at the field scale (about 20 hectares). High resolution land surface models are also able to provide solutions at the same scale. In this study, we investigated whether the assimilation of soil moisture retrievals from CRNS data measured by a network of nine CRNS located in the Rur catchment in Germany (2354 km2) can improve land surface model prediction. The assimilation of soil moisture retrievals from neutron count intensity data was used to update model states and parameters of the land surface model CLM 4.5 over a two year time period, followed by a one year evaluation period without updates. This updating was done with the local ensemble transform Kalman filter. The real world experiment tested the value of CRNS using jackknifing experiments and three different initial soil maps. During the assimilation period, soil moisture predictions generally improved, for a biased soil map from an RMSE of 0.11 cm3/cm3 in the open loop run to 0.03 cm3/cm3 while during the evaluation period soil moisture predictions improved from 0.12 cm3/cm3 to 0.06 cm3

  8. Resource Discovery in Activity-Based Sensor Networks

    DEFF Research Database (Denmark)

    Bucur, Doina; Bardram, Jakob

    This paper proposes a service discovery protocol for sensor networks that is specifically tailored for use in humancentered pervasive environments. It uses the high-level concept of computational activities (as logical bundles of data and resources) to give sensors in Activity-Based Sensor Networ...

  9. Measurements of neutrons at JET by means of the activation methods

    Energy Technology Data Exchange (ETDEWEB)

    Prokopowicz, R., E-mail: prokopowicz@ifpilm.waw.p [EURATOM-IPPLM Association, 23, Hery St, Warsaw 01-497 (Poland); Bienkowska, B.; Drozdowicz, K.; Jednorog, S.; Kowalska-Strzeciwilk, E. [EURATOM-IPPLM Association, 23, Hery St, Warsaw 01-497 (Poland); Murari, A. [EURATOM-ENEA Fusion Association, Consorzio RFX, Padova I-35127 (Italy); Popovichev, S. [EURATOM-CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Pytel, K.; Scholz, M.; Szydlowski, A. [EURATOM-IPPLM Association, 23, Hery St, Warsaw 01-497 (Poland); Syme, B. [EURATOM-CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Tracz, G. [EURATOM-IPPLM Association, 23, Hery St, Warsaw 01-497 (Poland)

    2011-05-01

    The neutron diagnostics in tokamaks like Joint European Torus (JET) are essential in estimating fusion power. The neutron activation method, supported by neutron transport calculations, is particularly useful for the evaluation of the total neutron yield from a single plasma discharge. This paper presents the results of activation experiments and calculations carried out for JET plasmas, from the selection of the activation materials to their irradiations in the neutron field of JET discharges. Neutron transport calculations were performed, leading to activation coefficients for new materials. The results of the calculations were used to design new composite samples to obtain information on both the yield and the neutron spectrum. The neutron measurements using these new activation materials were performed during the last JET experimental campaigns. The results are compared with neutron transport calculations. Additionally, application of the cadmium difference method allows revelation of the part of thermal neutrons near the tokamak first wall. The advantages of new activation materials and benchmarking the activation method against neutron transport calculations are also discussed.

  10. Towards a methodology for large-sample prompt-gamma neutron-activation analysis

    NARCIS (Netherlands)

    Degenaar, I.H.

    2004-01-01

    Large-sample prompt-gamma neutron-activation analysis, or shortly LS PGNAA, is a method by which mass fractions of elements can be determined in large samples with a mass over 1 kg. In this method the large sample is irradiated with neutrons. Directly (prompt) after absorption of the neutrons photon

  11. Determination of europium content in Li2SiO3(Eu) by neutron activation analysis using Am-Be neutron source.

    Science.gov (United States)

    Naik, Yeshwant; Tapase, Anant Shamrao; Mhatre, Amol; Datrik, Chandrashekhar; Tawade, Nilesh; Kumar, Umesh; Naik, Haladhara

    2016-12-01

    Circulardiscs of Li2SiO3 doped with europium were prepared and a new activation procedure for the neutron dose estimation in a breeder blanket of fusion reactor is described. The amount of europium in the disc was determined by neutron activation analysis (NAA) using an isotopic neutron source. The average neutron absorption cross section for the reaction was calculated using neutron distribution of the Am-Be source and available neutron absorption cross section data for the (151)Eu(n,γ)(152m)Eu reaction, which was used for estimation of europium in the pallet. The cross section of the elements varies with neutron energy, and the flux of the neutrons in each energy range seen by the nuclei under investigation also varies. Neutron distribution spectrum of the Am-Be source was worked out prior to NAA and the effective fractional flux for the nuclear reaction considered for the flux estimation was also determined.

  12. Magnetar activity mediated by plastic deformations of neutron star crust

    CERN Document Server

    Lyutikov, Maxim

    2014-01-01

    We advance a "Solar flare" model of magnetar activity, whereas a slow evolution of the magnetic field in the upper crust, driven by electron MHD (EMHD) flows, twists the external magnetic flux tubes, producing persistent emission, bursts and flares. At the same time the neutron star crust plastically relieves the imposed magnetic field stress, limiting the strain $ \\epsilon_t $ to values well below the critical strain $ \\epsilon_{crit}$ of a brittle fracture, $ \\epsilon_t \\sim 10^{-2}\\epsilon_{crit} $. Magnetar-like behavior, occurring near the magnetic equator, takes place in all neutron stars, but to a different extent. The persistent luminosity is proportional to cubic power of the magnetic field (at a given age), and hence is hardly observable in most rotationally powered neutron stars. Giant flares can occur only if the magnetic field exceeds some threshold value, while smaller bursts and flares may take place in relatively small magnetic fields. Bursts and flares are magnetospheric reconnection events t...

  13. Coincidence Prompt Gamma-Ray Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    R.P. gandner; C.W. Mayo; W.A. Metwally; W. Zhang; W. Guo; A. Shehata

    2002-11-10

    The normal prompt gamma-ray neutron activation analysis for either bulk or small beam samples inherently has a small signal-to-noise (S/N) ratio due primarily to the neutron source being present while the sample signal is being obtained. Coincidence counting offers the possibility of greatly reducing or eliminating the noise generated by the neutron source. The present report presents our results to date on implementing the coincidence counting PGNAA approach. We conclude that coincidence PGNAA yields: (1) a larger signal-to-noise (S/N) ratio, (2) more information (and therefore better accuracy) from essentially the same experiment when sophisticated coincidence electronics are used that can yield singles and coincidences simultaneously, and (3) a reduced (one or two orders of magnitude) signal from essentially the same experiment. In future work we will concentrate on: (1) modifying the existing CEARPGS Monte Carlo code to incorporate coincidence counting, (2) obtaining coincidence schemes for 18 or 20 of the common elements in coal and cement, and (3) optimizing the design of a PGNAA coincidence system for the bulk analysis of coal.

  14. RADSAT Benchmarks for Prompt Gamma Neutron Activation Analysis Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Kimberly A.; Gesh, Christopher J.

    2011-07-01

    The accurate and efficient simulation of coupled neutron-photon problems is necessary for several important radiation detection applications. Examples include the detection of nuclear threats concealed in cargo containers and prompt gamma neutron activation analysis for nondestructive determination of elemental composition of unknown samples. High-resolution gamma-ray spectrometers are used in these applications to measure the spectrum of the emitted photon flux, which consists of both continuum and characteristic gamma rays with discrete energies. Monte Carlo transport is the most commonly used simulation tool for this type of problem, but computational times can be prohibitively long. This work explores the use of multi-group deterministic methods for the simulation of coupled neutron-photon problems. The main purpose of this work is to benchmark several problems modeled with RADSAT and MCNP to experimental data. Additionally, the cross section libraries for RADSAT are updated to include ENDF/B-VII cross sections. Preliminary findings show promising results when compared to MCNP and experimental data, but also areas where additional inquiry and testing are needed. The potential benefits and shortcomings of the multi-group-based approach are discussed in terms of accuracy and computational efficiency.

  15. Coarse-scaling adjustment of fine-group neutron spectra for epithermal neutron beams in BNCT using multiple activation detectors

    Science.gov (United States)

    Liu, Yuan-Hao; Nievaart, Sander; Tsai, Pi-En; Liu, Hong-Ming; Moss, Ray; Jiang, Shiang-Huei

    2009-01-01

    In order to provide an improved and reliable neutron source description for treatment planning in boron neutron capture therapy (BNCT), a spectrum adjustment procedure named coarse-scaling adjustment has been developed and applied to the neutron spectrum measurements of both the Tsing Hua Open-pool Reactor (THOR) epithermal neutron beam in Taiwan and the High Flux Reactor (HFR) in The Netherlands, using multiple activation detectors. The coarse-scaling adjustment utilizes a similar idea as the well-known two-foil method, which adjusts the thermal and epithermal neutron fluxes according to the Maxwellian distribution for thermal neutrons and 1/ E distribution over the epithermal neutron energy region. The coarse-scaling adjustment can effectively suppress the number of oscillations appearing in the adjusted spectrum and provide better smoothness. This paper also presents a sophisticated 9-step process utilizing twice the coarse-scaling adjustment which can adjust a given coarse-group spectrum into a fine-group structure, i.e. 640 groups, with satisfactory continuity and excellently matched reaction rates between measurements and calculation. The spectrum adjustment algorithm applied in this study is the same as the well-known SAND-II.

  16. Physical Human Activity Recognition Using Wearable Sensors

    Directory of Open Access Journals (Sweden)

    Ferhat Attal

    2015-12-01

    Full Text Available This paper presents a review of different classification techniques used to recognize human activities from wearable inertial sensor data. Three inertial sensor units were used in this study and were worn by healthy subjects at key points of upper/lower body limbs (chest, right thigh and left ankle. Three main steps describe the activity recognition process: sensors’ placement, data pre-processing and data classification. Four supervised classification techniques namely, k-Nearest Neighbor (k-NN, Support Vector Machines (SVM, Gaussian Mixture Models (GMM, and Random Forest (RF as well as three unsupervised classification techniques namely, k-Means, Gaussian mixture models (GMM and Hidden Markov Model (HMM, are compared in terms of correct classification rate, F-measure, recall, precision, and specificity. Raw data and extracted features are used separately as inputs of each classifier. The feature selection is performed using a wrapper approach based on the RF algorithm. Based on our experiments, the results obtained show that the k-NN classifier provides the best performance compared to other supervised classification algorithms, whereas the HMM classifier is the one that gives the best results among unsupervised classification algorithms. This comparison highlights which approach gives better performance in both supervised and unsupervised contexts. It should be noted that the obtained results are limited to the context of this study, which concerns the classification of the main daily living human activities using three wearable accelerometers placed at the chest, right shank and left ankle of the subject.

  17. Active Sensor Configuration Validation for Refrigeration Systems

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Blanke, Mogens; Niemann, Hans Henrik

    2010-01-01

    Major faults in the commissioning phase of refrigeration systems are caused by defects related to sensors. With a number of similar sensors available that do not differ by type but only by spatial location in the plant, interchange of sensors is a common defect. With sensors being used quite...... identify the sensor configuration. The method as such is generic and is shown in the paper to work convincingly on refrigeration systems with significant nonlinear behaviors...

  18. Active Pixel Sensors: Are CCD's Dinosaurs?

    Science.gov (United States)

    Fossum, Eric R.

    1993-01-01

    Charge-coupled devices (CCD's) are presently the technology of choice for most imaging applications. In the 23 years since their invention in 1970, they have evolved to a sophisticated level of performance. However, as with all technologies, we can be certain that they will be supplanted someday. In this paper, the Active Pixel Sensor (APS) technology is explored as a possible successor to the CCD. An active pixel is defined as a detector array technology that has at least one active transistor within the pixel unit cell. The APS eliminates the need for nearly perfect charge transfer -- the Achilles' heel of CCDs. This perfect charge transfer makes CCD's radiation 'soft,' difficult to use under low light conditions, difficult to manufacture in large array sizes, difficult to integrate with on-chip electronics, difficult to use at low temperatures, difficult to use at high frame rates, and difficult to manufacture in non-silicon materials that extend wavelength response.

  19. Neutron distribution and induced activity inside a Linac treatment room.

    Science.gov (United States)

    Juste, B; Miró, R; Verdú, G; Díez, S; Campayo, J M

    2015-01-01

    Induced radioactivity and photoneutron contamination inside a radiation therapy bunker of a medical linear accelerator (Linac) is investigated in this work. The Linac studied is an Elekta Precise electron accelerator which maximum treatment photon energy is 15 MeV. This energy exceeds the photonuclear reaction threshold (around 7 MeV for high atomic number metals). The Monte Carlo code MCNP6 has been used for quantifying the neutron contamination inside the treatment room for different gantry rotation configuration. Walls activation processes have also been simulated. The approach described in this paper is useful to prevent the overexposure of patients and medical staff.

  20. Neutron activation study of gold-decorated singlewall carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Rafael G.F.; Oliveira, Arno H. de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Ladeira, Luiz O.; Lacerda, Rodrigo G.; Oliveira, Sergio de; Pinheiro, Mauricio V.B. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Fisica; Ferreira, Andrea V. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2007-07-01

    Single-wall carbon nanotubes (SWNT) were synthesized by arc discharge technique of doped graphite electrodes and purified by burning the amorphous carbon and removing the metals with hydrochloric acid (HCl). The nanotubes were also functionalized with carboxyl groups (-COOH) by ultrasonification with nitric (HNO{sub 3}) and sulfuric (H{sub 2}SO{sub 4}) acids. The nanotubes were then decorated with gold by reducing chloroauric acid (HAuCl{sub 4}) with UV and hydrazine (N{sub 2}H{sub 4}). Atomic Force Microscope (AFM) images confirmed the decoration with the hydrazine route. The gold concentration in the samples was analyzed by neutron activation analysis. (author)

  1. Evaluation of Am-Li neutron spectra data for active well type neutron multiplicity measurements of uranium

    Science.gov (United States)

    Goddard, Braden; Croft, Stephen; Lousteau, Angela; Peerani, Paolo

    2016-09-01

    Safeguarding nuclear material is an important and challenging task for the international community. One particular safeguards technique commonly used for uranium assay is active neutron correlation counting. This technique involves irradiating unused uranium with (α, n) neutrons from an Am-Li source and recording the resultant neutron pulse signal which includes induced fission neutrons. Although this non-destructive technique is widely employed in safeguards applications, the neutron energy spectra from an Am-Li sources is not well known. Several measurements over the past few decades have been made to characterize this spectrum; however, little work has been done comparing the measured and theoretical spectra of various Am-Li sources to each other. This paper examines fourteen different Am-Li spectra, focusing on how these spectra affect simulated neutron multiplicity results using the code Monte Carlo N-Particle eXtended (MCNPX). Two measurement and simulation campaigns were completed using Active Well Coincidence Counter (AWCC) detectors and uranium standards of varying enrichment. The results of this work indicate that for standard AWCC measurements, the fourteen Am-Li spectra produce similar doubles and triples count rates. The singles count rates varied by as much as 20% between the different spectra, although they are usually not used in quantitative analysis, being dominated by scattering which is highly dependent on item placement.

  2. Abnormal Activity Detection Using Pyroelectric Infrared Sensors

    Directory of Open Access Journals (Sweden)

    Xiaomu Luo

    2016-06-01

    Full Text Available Healthy aging is one of the most important social issues. In this paper, we propose a method for abnormal activity detection without any manual labeling of the training samples. By leveraging the Field of View (FOV modulation, the spatio-temporal characteristic of human activity is encoded into low-dimension data stream generated by the ceiling-mounted Pyroelectric Infrared (PIR sensors. The similarity between normal training samples are measured based on Kullback-Leibler (KL divergence of each pair of them. The natural clustering of normal activities is discovered through a self-tuning spectral clustering algorithm with unsupervised model selection on the eigenvectors of a modified similarity matrix. Hidden Markov Models (HMMs are employed to model each cluster of normal activities and form feature vectors. One-Class Support Vector Machines (OSVMs are used to profile the normal activities and detect abnormal activities. To validate the efficacy of our method, we conducted experiments in real indoor environments. The encouraging results show that our method is able to detect abnormal activities given only the normal training samples, which aims to avoid the laborious and inconsistent data labeling process.

  3. Abnormal Activity Detection Using Pyroelectric Infrared Sensors.

    Science.gov (United States)

    Luo, Xiaomu; Tan, Huoyuan; Guan, Qiuju; Liu, Tong; Zhuo, Hankz Hankui; Shen, Baihua

    2016-06-03

    Healthy aging is one of the most important social issues. In this paper, we propose a method for abnormal activity detection without any manual labeling of the training samples. By leveraging the Field of View (FOV) modulation, the spatio-temporal characteristic of human activity is encoded into low-dimension data stream generated by the ceiling-mounted Pyroelectric Infrared (PIR) sensors. The similarity between normal training samples are measured based on Kullback-Leibler (KL) divergence of each pair of them. The natural clustering of normal activities is discovered through a self-tuning spectral clustering algorithm with unsupervised model selection on the eigenvectors of a modified similarity matrix. Hidden Markov Models (HMMs) are employed to model each cluster of normal activities and form feature vectors. One-Class Support Vector Machines (OSVMs) are used to profile the normal activities and detect abnormal activities. To validate the efficacy of our method, we conducted experiments in real indoor environments. The encouraging results show that our method is able to detect abnormal activities given only the normal training samples, which aims to avoid the laborious and inconsistent data labeling process.

  4. Ground water and snow sensor based on directional detection of cosmogenic neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Robert Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Marleau, Peter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffin, Patrick J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2011-06-01

    A fast neutron detector is being developed to measure the cosmic ray neutron flux in order to measure soil moisture. Soil that is saturated with water has an enhanced ability to moderate fast neutrons, removing them from the backscatter spectrum. The detector is a two-element, liquid scintillator detector. The choice of liquid scintillator allows rejection of gamma background contamination from the desired neutron signal. This enhances the ability to reconstruct the energy and direction of a coincident neutron event. The ability to image on an event-by-event basis allows the detector to selectively scan the neutron flux as a function of distance from the detector. Calibrations, simulations, and optimization have been completed to understand the detector response to neutron sources at variable distances and directions. This has been applied to laboratory background measurements in preparation for outdoor field tests.

  5. A method to determine validity and reliability of activity sensors

    NARCIS (Netherlands)

    Boerema, S.T.; Hermens, H.J.

    2013-01-01

    METHOD Four sensors were securely fastened to a mechanical oscillator (Vibration Exciter, type 4809, Brüel & Kjær) and moved at various frequencies (6.67Hz; 13.45Hz; 19.88Hz) within the range of human physical activity. For each of the three sensor axes, the sensors were simultaneously moved for fiv

  6. Controlling the Dissolution of Realgar by Neutron Activation

    Directory of Open Access Journals (Sweden)

    Pujić, Z.

    2009-03-01

    Full Text Available Radioanalytical method for monitoring of separation of arsenic from realgar ore through As-76 was described. The procedure follows the distribution of radioactive components between a liquid and a solid phase in any kind of chemical treatment.The method is applicable in examination of metallurgical procedures with natural materials that are characterized with a high cross section for neutron capture. The method can be applied in examination of samples containing mercury (II sulphide HgS, which are not suitable for conventional chemical treatments concerning ecological risks.The samples examined were from Vareš mine zone - a sample of realgar ore and a sample of dolomite. The realgar seam has not been treated separately, but the sample has been collected by flotation in a concentrate which is a mixture of different ores in Vares mine area. We assumed that such seams should be treated separately, and not as a part of an ore concentrate, because arsenic is only a trace element in a concentrate collected (0.2 % – 0.4 %, and its separation is therefore difficult. A sample of realgar ore has been irradiated with a neutron source americium – 241/beryllium with neutron flux 2.6×107 n s-1. The radio analytical procedure proposed consists of three main phases:– The investigated sample is irradiated in a neutron source and gamma-spectrometrically charecterised.– An identical sample is exposed to any kind of chemical treatment. A part of the sample that isnot dissolved is then separated and the remainder is gamma-spectrometrically characterized aswell.– When the obtained gamma spectra are compared, the information on distribution of radionuclides is gained, and the yield of dissolving process is defined.Reliability of the neutron activation method depends on the neutron source used, but also on the quality of gamma-spectrometer. A typical gamma spectrum of a realgar sample (0.5 g, after it has been irradiated in a neutron source, was recorded on

  7. Active neutron methods for nuclear safeguards applications using Helium-4 gas scintillation detectors

    Science.gov (United States)

    Lewis, Jason M.

    Active neutron methods use a neutron source to interrogate fissionable material. In this work a 4He gas scintillation fast neutron detection system is used to measure neutrons created by the interrogation. Three new applications of this method are developed: spent nuclear fuel assay, fission rate measurement, and special nuclear material detection. Three active neutron methods are included in this thesis. First a non-destructive plutonium assay technique called Multispectral Active Neutron Interrogation Analysis is developed. It is based on interrogating fuel with neutrons at several different energies. The induced fission rates at each interrogation energy are compared with results from a neutron transport model of the irradiation geometry in a system of equations to iteratively solve the inverse problem for isotopic composition. The model is shown to converge on the correct composition for a material with 3 different fissionable components, a representative neutron absorber, and any neutron transparent material such as oxygen in a variety of geometries. Next an experimental fission rate measurement technique is developed using 4He gas scintillation fast neutron detector. Several unique features of this detector allow it to detect and provide energy information on fast neutrons with excellent gamma discrimination efficiency. The detector can measure induced fission rate by energetically differentiating between interrogation neutrons and higher energy fission neutrons. The detector response to a mono-energetic deuterium-deuterium fusion neutron generator and a 252Cf source are compared to examine the difference in detected energy range. Finally we demonstrate a special nuclear material detection technique by detecting an unambiguous fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium neutron generator and a high pressure 4He gas fast neutron scintillation detector. Energy histograms resulting from this

  8. Monte Carlo Calculation for Landmine Detection using Prompt Gamma Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seungil; Kim, Seong Bong; Yoo, Suk Jae [Plasma Technology Research Center, Gunsan (Korea, Republic of); Shin, Sung Gyun; Cho, Moohyun [POSTECH, Pohang (Korea, Republic of); Han, Seunghoon; Lim, Byeongok [Samsung Thales, Yongin (Korea, Republic of)

    2014-05-15

    Identification and demining of landmines are a very important issue for the safety of the people and the economic development. To solve the issue, several methods have been proposed in the past. In Korea, National Fusion Research Institute (NFRI) is developing a landmine detector using prompt gamma neutron activation analysis (PGNAA) as a part of the complex sensor-based landmine detection system. In this paper, the Monte Carlo calculation results for this system are presented. Monte Carlo calculation was carried out for the design of the landmine detector using PGNAA. To consider the soil effect, average soil composition is analyzed and applied to the calculation. This results has been used to determine the specification of the landmine detector.

  9. Neutron measurements with ultra-thin 3D silicon sensors in a radiotherapy treatment room using a Siemens PRIMUS linac

    Science.gov (United States)

    Guardiola, C.; Gómez, F.; Fleta, C.; Rodríguez, J.; Quirion, D.; Pellegrini, G.; Lousa, A.; Martínez-de-Olcoz, L.; Pombar, M.; Lozano, M.

    2013-05-01

    The accurate detection and dosimetry of neutrons in mixed and pulsed radiation fields is a demanding instrumental issue with great interest both for the industrial and medical communities. In recent studies of neutron contamination around medical linacs, there is a growing concern about the secondary cancer risk for radiotherapy patients undergoing treatment in photon modalities at energies greater than 6 MV. In this work we present a promising alternative to standard detectors with an active method to measure neutrons around a medical linac using a novel ultra-thin silicon detector with 3D electrodes adapted for neutron detection. The active volume of this planar device is only 10 µm thick, allowing a high gamma rejection, which is necessary to discriminate the neutron signal in the radiotherapy peripheral radiation field with a high gamma background. Different tests have been performed in a clinical facility using a Siemens PRIMUS linac at 6 and 15 MV. The results show a good thermal neutron detection efficiency around 2% and a high gamma rejection factor.

  10. Neutron formation temperature gauge and neutron activation analysis brine flow meter. Final report, October 1, 1976--March 31, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Vagelatos, N.; Steinman, D.K.; John, J.

    1978-03-31

    Feasibility studies of nuclear techniques applicable to the determination of geothermal formation temperature and two-phase brine flow downhole have been performed. The formation temperature gauging technique involves injection of fast neutrons into the formation and analysis of the moderated slow neutron energy distribution by appropriately filtered neutron detectors. The scientific feasibility of the method has been demonstrated by analytical computational and experimental evaluation of the system response. A data analysis method has been developed to determine unambiguously the temperature, neutron absorption cross section and neutron moderating power of an arbitrary medium. The initial phase of a program to demonstrate the engineering feasibility of the technique has been performed. A sonde mockup was fabricated and measurements have been performed in a test stand designed to simulate a geothermal well. The results indicate that the formation temperature determined by this method is independent of differences between the temperature in the borehole fluid and the formation, borehole fluid density, and borehole fluid salinity. Estimates of performance specifications for a formation temperature sonde have been made on the basis of information obtained in this study and a conceptual design of a logging system has been developed. The technique for the determination of fluid flow in a well is based on neutron activation analysis of elements present in the brine. An analytical evaluation of the method has been performed. The results warrant further, experimental evaluation.

  11. Instrumental neutron activation analysis of sectioned hair strands for arsenic

    Energy Technology Data Exchange (ETDEWEB)

    Guinn, V.P. [Univ. of Maryland, College Park, MD (United States)

    1996-12-31

    Instrumental neutron activation analysis (INAA) is a valuable and proven method for the quantitative analysis of sectioned human head hair specimens for arsenic - and, if arsenic is found to be present at high concentrations, the approximate times when it was ingested. Reactor-flux thermal-neutron activation of the hair samples produces 26.3-h {sup 76}As, which is then detected by germanium gamma-ray spectrometry, measuring the 559.1-keV gamma-ray peak of {sup 76}As. Even normal levels of arsenic in hair, in the range of <1 ppm up to a few parts per million of arsenic can be measured - and the far higher levels associated with large internal doses of arsenic, levels approaching or exceeding 100 ppm arsenic, are readily and accurately measurable. However, all phases of forensic investigations of possible chronic (or in some cases, acute) arsenic poisoning are important, i.e., not just the analysis phase. All of these phases are discussed in this paper, based on the author`s experience and the experience of others, in criminal cases. Cases of chronic arsenic poisoning often reveal a series of two to four doses, perhaps a few months apart, with increasing doses.

  12. The calibration of DD neutron indium activation diagnostic for Shenguang-III facility

    CERN Document Server

    Song, Zi-Feng; Liu, Zhong-Jie; Zhan, Xia-Yu; Tang, Qi

    2014-01-01

    The indium activation diagnostic was calibrated on an accelerator neutron source in order to diagnose deuterium-deuterium (DD) neutron yields of implosion experiments on Shenguang-III facility. The scattered neutron background of the accelerator room was measured by placing a polypropylene shield in front of indium sample, in order to correct the calibrated factor of this activation diagnostic. The proper size of this shield was given by Monte Carlo simulation software. The affect from some other activated nuclei on the calibration was verified by judging whether the measured curve obeys exponential decay and contrasting the half life of the activated sample. The calibration results showed that the linear range reached up to 100 cps net count rate in the full energy peak of interest, the scattered neutron background of accelerator room was about 9% of the total neutrons and the possible interferences mixed scarcely in the sample. Subtracting the portion induced by neutron background, the calibrated factor of ...

  13. Current status of neutron activation analysis using the Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen Van Suc; Nguyen Mong Sinh [Nuclear Research Institute, Dalat (Viet Nam)

    1999-10-01

    Neutron activation analysis is one of the most sensitive, rapid, accurated methods for determination of trace elements in different materials. A review is made of the current status of the activities and the results in studying and developing NAA (Neutron Activation Analysis) at the Dalat Nuclear Research Institute and applying this method to different sectors of science and technology in Vietnam. (author)

  14. Precision Geolocation of Active Electromagnetic Sensors Using Stationary Magnetic Sensors

    Science.gov (United States)

    2009-09-01

    sensors typically involve the use of real-time-kinematic ( RTK ) GPS or line-of-sight laser technologies such as RTS augmented with pitch and roll...studied the accuracy of various positional systems in a wooded environment, including GPS , RTS, the ENSCO Ranger System (based on time- modulated ultra...convenient local reference • Real-time kinematics ( RTK ) enabled GPS receivers mounted on the EM63 and a separate surveying pole. The field where

  15. Epithermal Neutron Activation Analysis of the Asian Herbal Plants

    Science.gov (United States)

    Baljinnyam, N.; Jugder, B.; Norov, N.; Frontasyeva, M. V.; Ostrovnaya, T. M.; Pavlov, S. S.

    2011-06-01

    Asian medicinal herbs Chrysanthemum (Spiraea aquilegifolia Pall.) and Red Sandalwood (Pterocarpus Santalinus) are widely used in folk and Ayurvedic medicine for healing and preventing some diseases. The modern medical science has proved that the Chrysanthemum (Spiraea aquilegifolia Pall.) possesses the following functions: reducing blood press, dispelling cancer cell, coronary artery's expanding and bacteriostating and Red Sandalwood (Pterocarpus Santalinus) is recommended against headache, toothache, skin diseases, vomiting and sometimes it is taken for treatment of diabetes. Species of Chrysanthemums were collected in the north-eastern and central Mongolia, and the Red Sandalwood powder was imported from India. Samples of Chrysanthemums (branches, flowers and leaves) (0.5 g) and red sandalwood powder (0.5 g) were subjected to the multi-element instrumental neutron activation analysis using epithermal neutrons (ENAA) at the IBR-2 reactor, Frank Laboratory of Neutron Physics (FLNP) JINR, Dubna. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Cd, Cs, Ba, La, Hf, Ta, W, Sb, Au, Hg, Ce, Nd, Sm, Eu, Tb, Dy, Yb, Th, U, Lu) were determined. For the first time such a large group of elements was determined in the herbal plants used in Mongolia. The quality control of the analytical results was provided by using certified reference material Bowen Cabbage. The results obtained are compared to the "Reference plant» data (B. Markert, 1992) and interpreted in terms of excess of such elements as Se, Cr, Ca, Fe, Ni, Mo, and rare earth elements.

  16. Analysis of Some Egyptian Cosmetic Samples by Fast Neutron Activation Analysis

    CERN Document Server

    Medhat, M E; Fayez-Hassan, M

    2001-01-01

    A description of D-T neutron generator (NG) is presented. This generator can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. In our work, the concentration of the elements Na, Mg, Al, Si, K, Cl, Ca and Fe, were determined in two domestic brands of face powder by using 14 MeV neutron activation analysis.

  17. An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

    Science.gov (United States)

    Nohtomi, Akihiro; Kurihara, Ryosuke; Kinoshita, Hiroyuki; Honda, Soichiro; Tokunaga, Masaaki; Uno, Heita; Shinsho, Kiyomitsu; Wakabayashi, Genichiro; Koba, Yusuke; Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko; Ohga, Saiji

    2016-10-01

    In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement.

  18. Active detection of shielded SNM with 60-keV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Hagmann, C; Dietrich, D; Hall, J; Kerr, P; Nakae, L; Newby, R; Rowland, M; Snyderman, N; Stoeffl, W

    2008-07-08

    Fissile materials, e.g. {sup 235}U and {sup 239}Pu, can be detected non-invasively by active neutron interrogation. A unique characteristic of fissile material exposed to neutrons is the prompt emission of high-energy (fast) fission neutrons. One promising mode of operation subjects the object to a beam of medium-energy (epithermal) neutrons, generated by a proton beam impinging on a Li target. The emergence of fast secondary neutrons then clearly indicates the presence of fissile material. Our interrogation system comprises a low-dose 60-keV neutron generator (5 x 10{sup 6}/s), and a 1 m{sup 2} array of scintillators for fast neutron detection. Preliminary experimental results demonstrate the detectability of small quantities (370 g) of HEU shielded by steel (200 g/cm{sup 2}) or plywood (30 g/cm{sup 2}), with a typical measurement time of 1 min.

  19. A kinematically beamed, low energy pulsed neutron source for active interrogation

    Science.gov (United States)

    Dietrich, Dan; Hagmann, Chris; Kerr, Phil; Nakae, Les; Rowland, Mark; Snyderman, Neal; Stoeffl, Wolfgang; Hamm, Robert

    2005-12-01

    We are developing a new active interrogation system based on a kinematically focused low energy neutron beam. The key idea is that one of the defining characteristics of special nuclear materials (SNM) is the ability for low energy or thermal neutrons to induce fission. Thus by using low energy neutrons for the interrogation source we can accomplish three goals: (1) energy discrimination allows us to measure the prompt fast fission neutrons produced while the interrogation beam is on; (2) neutrons with an energy of approximately 60-100 keV do not fission 238U and Thorium, but penetrate bulk material nearly as far as high energy neutrons do and (3) below about 100 keV neutrons lose their energy by kinematical collisions rather than via the nuclear (n, 2n) or (n, n‧) processes thus further simplifying the prompt neutron induced background. 60 keV neutrons create a low radiation dose and readily thermal capture in normal materials, thus providing a clean spectroscopic signature of the intervening materials. The kinematically beamed source also eliminates the need for heavy backward and sideway neutron shielding. We have designed and built a very compact pulsed neutron source, based on an RFQ proton accelerator and a lithium target. We are developing fast neutron detectors that are nearly insensitive to the ever-present thermal neutron and neutron capture induced gamma ray background. The detection of only a few high energy fission neutrons in time correlation with the linac pulse will be a clear indication of the presence of SNM.

  20. Neutron activation analysis for the demonstration of amphibolite rock-weathering activity of a yeast.

    Science.gov (United States)

    Rades-Rohkohl, E; Hirsch, P; Fränzle, O

    1979-12-01

    Neutron activation analysis was employed in a survey of weathering abilities of rock surface microorganisms. A yeast isolated from an amphibolite of a megalithic grave was found actively to concentrate, in media and in or on cells, iron and other elements when grown in the presence of ground rock. This was demonstrated by comparing a spectrum of neutron-activated amphibolite powder (particle size, 50 to 100 mum) with the spectra of neutron-activated, lyophilized yeast cells which had grown with or without amphibolite powder added to different media. The most active yeast (IFAM 1171) did not only solubilize Fe from the rock powder, but significant amounts of Co, Eu, Yb, Ca, Ba, Sc, Lu, Cr, Th, and U were also mobilized. The latter two elements occurred as natural radioactive isotopes in this amphibolite. When the yeast cells were grown with neutron-activated amphibolite, the cells contained the same elements. Furthermore, the growth medium contained Fe, Co, and Eu which had been solubilized from the amphibolite. This indicates the presence, in this yeast strain, of active rockweathering abilities as well as of uptake mechanisms for solubilized rock components.

  1. Characterization of active CMOS sensors for capacitively coupled pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hirono, Toko; Gonella, Laura; Janssen, Jens; Hemperek, Tomasz; Huegging, Fabian; Krueger, Hans; Wermes, Norbert [Institute of Physics, University of Bonn (Germany); Peric, Ivan [Institut fuer Prozessdatenverarbeitung und Elektronik, Karlsruher Institut fuer Technologie, Karlsruhe (Germany)

    2015-07-01

    Active CMOS pixel sensor is one of the most attractive candidates for detectors of upcoming particle physics experiments. In contrast to conventional sensors of hybrid detectors, signal processing circuit can be integrated in the active CMOS sensor. The characterization and optimization of the pixel circuit are indispensable to obtain a good performance from the sensors. The prototype chips of the active CMOS sensor were fabricated in the AMS 180nm and L-Foundry 150 nm CMOS processes, respectively a high voltage and high resistivity technology. Both chips have a charge sensitive amplifier and a comparator in each pixel. The chips are designed to be glued to the FEI4 pixel readout chip. The signals from 3 pixels of the prototype chips are capacitively coupled to the FEI4 input pads. We have performed lab tests and test beams to characterize the prototypes. In this presentation, the measurement results of the active CMOS prototype sensors are shown.

  2. Measurements of the neutron activation cross sections for Bi and Co at 386 MeV.

    Science.gov (United States)

    Yashima, H; Sekimoto, S; Ninomiya, K; Kasamatsu, Y; Shima, T; Takahashi, N; Shinohara, A; Matsumura, H; Satoh, D; Iwamoto, Y; Hagiwara, M; Nishiizumi, K; Caffee, M W; Shibata, S

    2014-10-01

    Neutron activation cross sections for Bi and Co at 386 MeV were measured by activation method. A quasi-monoenergetic neutron beam was produced using the (7)Li(p,n) reaction. The energy spectrum of these neutrons has a high-energy peak (386 MeV) and a low-energy tail. Two neutron beams, 0° and 25° from the proton beam axis, were used for sample irradiation, enabling a correction for the contribution of the low-energy neutrons. The neutron-induced activation cross sections were estimated by subtracting the reaction rates of irradiated samples for 25° irradiation from those of 0° irradiation. The measured cross sections were compared with the findings of other studies, evaluated in relation to nuclear data files and the calculated data by Particle and Heavy Ion Transport code System code.

  3. Thin film cadmium telluride charged particle sensors for large area neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J. W.; Smith, L.; Calkins, J.; Mejia, I.; Cantley, K. D.; Chapman, R. A.; Quevedo-Lopez, M.; Gnade, B., E-mail: gnade@utdallas.edu [Materials Science and Engineering, University of Texas at Dallas, Richardson, Texas 75080 (United States); Kunnen, G. R.; Allee, D. R. [Flexible Display Center, Arizona State University, Phoenix, Arizona 85284 (United States); Sastré-Hernández, J.; Contreras-Puente, G. [Escuela Superior de Física y Matemáticas, Instituto Politécnico Nacional, Mexico City 07738 (Mexico); Mendoza-Pérez, R. [Universidad Autónoma de la Ciudad de México, Mexico City 09790 (Mexico)

    2014-09-15

    Thin film semiconductor neutron detectors are an attractive candidate to replace {sup 3}He neutron detectors, due to the possibility of low cost manufacturing and the potential for large areas. Polycrystalline CdTe is found to be an excellent material for thin film charged particle detectors—an integral component of a thin film neutron detector. The devices presented here are characterized in terms of their response to alpha and gamma radiation. Individual alpha particles are detected with an intrinsic efficiency of >80%, while the devices are largely insensitive to gamma rays, which is desirable so that the detector does not give false positive counts from gamma rays. The capacitance-voltage behavior of the devices is studied and correlated to the response due to alpha radiation. When coupled with a boron-based neutron converting material, the CdTe detectors are capable of detecting thermal neutrons.

  4. Application of neutron activation analysis system in Xi'an pulsed reactor

    CERN Document Server

    Zhang Wen Shou; Yu Qi

    2002-01-01

    Neutron Activation Analysis System in Xi'an Pulsed Reactor is consist of rabbit fast radiation system and experiment measurement system. The functions of neutron activation analysis are introduced. Based on the radiation system. A set of automatic data handling and experiment simulating system are built. The reliability of data handling and experiment simulating system had been verified by experiment

  5. Recognition of human activities with wearable sensors

    Science.gov (United States)

    He, Weihua; Guo, Yongcai; Gao, Chao; Li, Xinke

    2012-12-01

    A novel approach for recognizing human activities with wearable sensors is investigated in this article. The key techniques of this approach include the generalized discriminant analysis (GDA) and the relevance vector machines (RVM). The feature vectors extracted from the measured signal are processed by GDA, with its dimension remarkably reduced from 350 to 12 while fully maintaining the most discriminative information. The reduced feature vectors are then classified by the RVM technique according to an extended multiclass model, which shows good convergence characteristic. Experimental results on the Wearable Action Recognition Dataset demonstrate that our approach achieves an encouraging recognition rate of 99.2%, true positive rate of 99.18% and false positive rate of 0.07%. Although in most cases, the support vector machines model has more than 70 support vectors, the number of relevance vectors related to different activities is always not more than 4, which implies a great simplicity in the classifier structure. Our approach is expected to have potential in real-time applications or solving problems with large-scale datasets, due to its perfect recognition performance, strong ability in feature reduction, and simple classifier structure.

  6. Neutron activation analysis: Modelling studies to improve the neutron flux of Americium–Beryllium source

    National Research Council Canada - National Science Library

    Abdessamad Didi; Ahmed Dadouch; Otman Jaï; Jaouad Tajmouati; Hassane El Bekkouri

    2017-01-01

    Americium–beryllium (Am-Be; n, γ) is a neutron emitting source used in various research fields such as chemistry, physics, geology, archaeology, medicine, and environmental monitoring, as well as in the forensic sciences...

  7. Determination of hydrogen in niobium by cold neutron prompt gamma ray activation analysis and neutron incoherent scattering

    Energy Technology Data Exchange (ETDEWEB)

    R.L. Paul; H.H. Cheu-Maya; G.R. Myneni

    2002-11-01

    The presence of trace amounts of hydrogen in niobium is believed to have a detrimental effect on the mechanical and superconducting properties. Unfortunately, few techniques are capable of measuring hydrogen at these levels. We have developed two techniques for measuring hydrogen in materials. Cold neutron prompt gamma-ray activation analysis (PGAA) has proven useful for the determination of hydrogen and other elements in a wide variety of materials. Neutron incoherent scattering (NIS), a complementary tool to PGAA, has been used to measure trace hydrogen in titanium. Both techniques were used to study the effects of vacuum heating and chemical polishing on the hydrogen content of superconducting niobium.

  8. Clinical applications of in vivo neutron-activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.

    1982-01-01

    In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into and modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, enhancing uniformity, and reducing the dose required for the measurement. The work presently underway will yield significant data on a variety of environmental contaminants such as Cd. Compositional studies are determining the level of vital constituents such as nitrogen and potassium in both normal subjects and in patients with a variety of metabolic disorders. Therapeutic programs can be assessed while in progress.

  9. Neutron activation analysis of multimetallic accumulation in dolomites

    Directory of Open Access Journals (Sweden)

    Zovko Emira

    2008-01-01

    Full Text Available The reason for exploring polymetallic ores, which are found in dolomite structures of the Veovača and Borovica zone near Vareš, lies in the fact that there is very little information about its chemical structure. The isolated concentrates that we analyzed from surface mines, have shown significant difference in quantity of trace elements. Deep probing of the whole area was not performed, but there are presumptions that there are roots of ore-rich dolomites in the areas of 30 - 40 km. The future concept of exploitation of these mines in the Vareš zone would probably require deeper probing. There are prospects for finding higher quality deposits with significant quantities of polymetallic components. By the method of neutron activation analysis the existence of mercury in amounts of about 0.4 % was confirmed. Because of the presence of mercury, these concentrates are not appropriate for pyrometallurgy, since it may result in environment contamination.

  10. In-vivo neutron activation analysis: principles and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.

    1982-01-01

    In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into and modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, enhancing uniformity, and reducing the dose required for the measurement. The work presently underway will yield significant data on a variety of environmental contaminants such as Cd. Compositional studies are determining the level of vital constituents such as nitrogen and potassium in both normal subjects and in patients with a variety of metabolic disorders. Therapeutic programs can be assessed while in progress. It seems likely that by the end of this century there will have been significant progress with this research tool, and exciting insights obtained into the nature and dynamics of human body composition.

  11. Measurement of neutron flux spectra in a Tungsten Benchmark by neutron foil activation method

    OpenAIRE

    Negoita, Cezar Ciprian

    2004-01-01

    The nuclear design of fusion devices such as ITER (International Thermonuclear Experimental Reactor), which is an experimental fusion reactor based on the "tokamak" concept, rely on the results of neutron physical calculations. These depend on the knowledge of the neutron and photon flux spectra which is particularly important because it permits to anticipate the possible answers of the whole structure to phenomena such as nuclear heating, tritium breeding, atomic displaceme...

  12. Energy-aware activity classification using wearable sensor networks

    Science.gov (United States)

    Dong, Bo; Montoye, Alexander; Moore, Rebecca; Pfeiffer, Karin; Biswas, Subir

    2013-05-01

    This paper presents implementation details, system characterization, and the performance of a wearable sensor network that was designed for human activity analysis. Specific machine learning mechanisms are implemented for recognizing a target set of activities with both out-of-body and on-body processing arrangements. Impacts of energy consumption by the on-body sensors are analyzed in terms of activity detection accuracy for out-of-body processing. Impacts of limited processing abilities for the on-body scenario are also characterized in terms of detection accuracy, by varying the background processing load in the sensor units. Impacts of varying number of sensors in terms of activity classification accuracy are also evaluated. Through a rigorous systems study, it is shown that an efficient human activity analytics system can be designed and operated even under energy and processing constraints of tiny on-body wearable sensors.

  13. A triboelectric motion sensor in wearable body sensor network for human activity recognition.

    Science.gov (United States)

    Hui Huang; Xian Li; Ye Sun

    2016-08-01

    The goal of this study is to design a novel triboelectric motion sensor in wearable body sensor network for human activity recognition. Physical activity recognition is widely used in well-being management, medical diagnosis and rehabilitation. Other than traditional accelerometers, we design a novel wearable sensor system based on triboelectrification. The triboelectric motion sensor can be easily attached to human body and collect motion signals caused by physical activities. The experiments are conducted to collect five common activity data: sitting and standing, walking, climbing upstairs, downstairs, and running. The k-Nearest Neighbor (kNN) clustering algorithm is adopted to recognize these activities and validate the feasibility of this new approach. The results show that our system can perform physical activity recognition with a successful rate over 80% for walking, sitting and standing. The triboelectric structure can also be used as an energy harvester for motion harvesting due to its high output voltage in random low-frequency motion.

  14. Medical application of in vivo neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Zanzi, I.; Aloia, J.F.

    1978-01-01

    The clinical usefulness of total body neutron activation analysis (TBNAA) was clearly established at an IAEA panel meeting in Vienna in 1972. It is best demonstrated by the studies involving the measurement of total-body calcium. This measurement provides data useful for the diagnosis and management of metabolic bone disorders. It should be emphasized, however, that while most of the applications to date have involved calcium and phosphorus, the measurement of sodium, chlorine and nitrogen also appear to be useful clinically. Total-body calcium measurements utilizing TBNAA have been used in studies of osteoporosis to establish absolute and relative deficits of calcium in patients with this disease in comparison to a normal contrast population. Changes in total-body calcium (skeletal mass) have also been useful for quantitating the efficacy of various therapies in osteoporosis. Serial measurements over periods of years provide long-term balance data by direct measurement with a higher precision (+- 2%) than is possible by the use of any other technique. In the renal osteodystrophy observed in patients with renal failure, disorders of both calcium and phosphorus, as well as electrolyte disturbances, have been studied. The measure of total-body levels of these elements gives the clinician useful data upon which to design dialysis therapy. The measurement of bone changes in endocrine dysfunction has been studied, particularly in patients with thyroid and parathyroid disorders. In parathyroidectomy, the measurement of total-body calcium, post-operatively, can indicate the degree of bone resorption. Skeletal metabolism and body composition in acromegaly and Cushing's disease have also been investigated by TBNAA. Levels of cadmium in liver and kidney have also been measured in-vivo by prompt-gamma neutron activation and associated with hypertension, emphysema and cigarette smoking.

  15. Demonstration of a 4-Sensor Folded Sangac Sensor Array with Active Phase Biasing Scheme

    Institute of Scientific and Technical Information of China (English)

    Zhang-Qi Song; Ming-Ye Yang; Xue-Liang Zhang; Yong-Ming Hu

    2008-01-01

    A 4-sensor folded Sagnae sensor array with an active phase biasing scheme is presented. The overlapping of the signal and noise pulse is avoided through a time division multiplexing scheme and the noise pulses is eliminated almost completely. The scheme can address 16 sensors when the repeat frequency of input pulse is at 68.3 kHz. The alternative phase bias technique is demonstrated, which can provide sensors with stable phase bias. The future benefit of this technique is that the 1/f noise in the circuit can be suppressed.

  16. Comparison of active microwave and optical sensors

    NARCIS (Netherlands)

    Schwering, P.B.W.; Theil, A.

    2002-01-01

    This paper describes a number of projects at TNO-FEL in the field of sensor fusion of radar and electrooptical sensors. These fusion approaches consider land, air, and maritime scenarios for surveillance and autonomous detection tasks. Fusion benefits are present when uncorrelated and complementary

  17. Soil moisture estimation across scales with mobile sensors for Cosmic-Ray Neutrons - The influence of roads

    Science.gov (United States)

    Zacharias, Steffen; Köhli, Markus; Rosolem, Rafael; Piussi, Laura; Kasner, Mandy; Kögler, Simon; Iwema, Joost; Schröter, Ingmar; Mollenhauer, Hannes; Bumberger, Jan; Wollschläger, Ute; Dietrich, Peter; Schrön, Martin

    2017-04-01

    The regional monitoring of storage, movement, and quality of water is of crucial importance to practical applications such as agricultural production, water resources management, and flood, drought and climate change predictions. A very promising method to cover soil moisture dynamics at scales relevant for land management or modeling purposes is the method of Cosmic Ray Neutron Sensing (CRNS). While the stationary use of instrument has been applied successfully to monitor soil moisture dynamics at a spatial scale up to a footprint of 500 m, a new development, the mobile CRNS rover, promises to cover soil moisture patterns at regional scales. Recently published insights on the physics of the CRNS sensor's spatial response revealed a dynamical nature of the footprint radius depending upon the ambient sources of water as well as the fact that the sensor is highly sensitive to hydrogen in the immediate vicinity. The latter aspect is of particular critical relevance for the practical application of mobile CRNS. During CRNS rover campaigns the sensor is very often moved along existing roads and pathways and it can be assumed that the CRNS measurement could be biased towards road moisture conditions. Thus, precise knowledge about the underlying physics and the relationships between site heterogeneity and sensor response is an essential prerequisite for the successful enhancement of the CRNS rover method. The purpose of the presentation is to highlight this challenge. Here, we present results from dedicated experiments and neutron transport simulations, and will propose approaches to correct the CRNS signal depending on site-specific wetness conditions, road geometry, and road material.

  18. Tables for simplifying calculations of activities produced by thermal neutrons

    Science.gov (United States)

    Senftle, F.E.; Champion, W.R.

    1954-01-01

    The method of calculation described is useful for the types of work of which examples are given. It is also useful in making rapid comparison of the activities that might be expected from several different elements. For instance, suppose it is desired to know which of the three elements, cobalt, nickel, or vanadium is, under similar conditions, activated to the greatest extent by thermal neutrons. If reference is made to a cross-section table only, the values may be misleading unless properly interpreted by a suitable comparison of half-lives and abundances. In this table all the variables have been combined and the desired information can be obtained directly from the values of A 3??, the activity produced per gram per second of irradiation, under the stated conditions. Hence, it is easily seen that, under similar circumstances of irradiation, vanadium is most easily activated even though the cross section of one of the cobalt isotopes is nearly five times that of vanadium and the cross section of one of the nickel isotopes is three times that of vanadium. ?? 1954 Societa?? Italiana di Fisica.

  19. Thermal, intermediate and fast neutron flux measurements using activation detectors; Mesure des flux de neutrons thermiques, intermediaires et rapides au moyen de detecteurs par activation

    Energy Technology Data Exchange (ETDEWEB)

    Brisbois, J.; Lott, M.; Manent, G. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The problem of neutron flux measurements using activation detectors is studied in the particular case of protection research. It is shown how it possible, it is possible, using a known thermal flux, to organise a coherent calibration system for all the detectors. The rapid neutron detectors are calibrated with respect to a reference detector (phosphorus) in a natural uranium converter; the intermediate neutron detectors with respect to gold in the axial channel of ZOE. This method makes it possible to minimise the errors due to the activation cross-sections. A brief description is given of the counting room of the Pile Safety Study Service, as well of the practical utilisation characteristics of the counters employed. (authors) [French] Le probleme de la mesure des flux de neutrons au moyen de detecteurs par activation est etudie dans le cas particulier des etudes de protections. On montre comment, a partir d'un flux thermique connu, on peut organiser un systeme coherent d'etalonnage de tous les detecteurs. Les detecteurs de neutrons rapides sont etalonnes par rapport a un detecteur de reference (phosphore) dans un convertisseur en uranium naturel; les detecteurs de neutrons intermediaires, par rapport a l'or dans le canal axial de ZOE, Cette methode permet de minimiser les erreurs dues aux sections efficaces d'activation. On decrit sommairement la salle de comptage du Service d'Etudes de Protections de Piles et on indique les caracteristiques d'emploi pratique des detecteurs utilises. (auteurs)

  20. Real-Time Active Cosmic Neutron Background Reduction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald; Mitchell, Stephen; Guss, Paul

    2013-09-01

    Neutron counting using large arrays of pressurized 3He proportional counters from an aerial system or in a maritime environment suffers from the background counts from the primary cosmic neutrons and secondary neutrons caused by cosmic ray-induced mechanisms like spallation and charge-exchange reaction. This paper reports the work performed at the Remote Sensing Laboratory–Andrews (RSL-A) and results obtained when using two different methods to reduce the cosmic neutron background in real time. Both methods used shielding materials with a high concentration (up to 30% by weight) of neutron-absorbing materials, such as natural boron, to remove the low-energy neutron flux from the cosmic background as the first step of the background reduction process. Our first method was to design, prototype, and test an up-looking plastic scintillator (BC-400, manufactured by Saint Gobain Corporation) to tag the cosmic neutrons and then create a logic pulse of a fixed time duration (~120 μs) to block the data taken by the neutron counter (pressurized 3He tubes running in a proportional counter mode). The second method examined the time correlation between the arrival of two successive neutron signals to the counting array and calculated the excess of variance (Feynman variance Y2F)1 in the neutron count distribution from Poisson distribution. The dilution of this variance from cosmic background values ideally would signal the presence of man-made neutrons.2 The first method has been technically successful in tagging the neutrons in the cosmic-ray flux and preventing them from being counted in the 3He tube array by electronic veto—field measurement work shows the efficiency of the electronic veto counter to be about 87%. The second method has successfully derived an empirical relationship between the percentile non-cosmic component in a neutron flux and the Y2F of the measured neutron count distribution. By using shielding materials alone, approximately 55% of the neutron flux

  1. Search for reaction-in-flight neutrons using thulium activation at the National Ignition Facility

    Science.gov (United States)

    Grim, Gary; Rundberg, Robert; Tonchev, Anton; Fowler, Malcolm; Wilhelmy, Jerry; Archuleta, Tom; Bionta, Richard; Boswell, Mitzi; Gostic, Julie; Griego, Jeff; Knittel, Kenn; Klein, Andi; Moody, Ken; Shaughnessy, Dawn; Wilde, Carl; Yeamans, Charles

    2013-10-01

    We report on measurements of reaction-in-flight (RIF) neutrons at the National Ignition Facility. RIF neutrons are produced in cryogenically layered implision by up-scattered deuterium, or tritium ions that undergo subsequent fusion reactions. The rate of RIF neutron production is proportional to the fuel areal density (| | R) and ion-stopping length in the dense fuel assembly. Thus, RIF neutrons provide information on charge particle stopping in a strongly coupled plasma, where perturbative modeling breaks down. To measure RIF neutrons, a set of thulium activation foils was placed 50 cm from layered cryogenic implosions at the NIF. The reaction 169Tm(n,3n)167Tm has a neutron kinetic energy threshold of 14.96 MeV. We will present results from initial experiments performed during the spring of 2013. Prepared by LANL under Contract DE-AC-52-06-NA25396, TSPA, LA-UR-13-22085.

  2. Pixel pitch and particle energy influence on the dark current distribution of neutron irradiated CMOS image sensors.

    Science.gov (United States)

    Belloir, Jean-Marc; Goiffon, Vincent; Virmontois, Cédric; Raine, Mélanie; Paillet, Philippe; Duhamel, Olivier; Gaillardin, Marc; Molina, Romain; Magnan, Pierre; Gilard, Olivier

    2016-02-22

    The dark current produced by neutron irradiation in CMOS Image Sensors (CIS) is investigated. Several CIS with different photodiode types and pixel pitches are irradiated with various neutron energies and fluences to study the influence of each of these optical detector and irradiation parameters on the dark current distribution. An empirical model is tested on the experimental data and validated on all the irradiated optical imagers. This model is able to describe all the presented dark current distributions with no parameter variation for neutron energies of 14 MeV or higher, regardless of the optical detector and irradiation characteristics. For energies below 1 MeV, it is shown that a single parameter has to be adjusted because of the lower mean damage energy per nuclear interaction. This model and these conclusions can be transposed to any silicon based solid-state optical imagers such as CIS or Charged Coupled Devices (CCD). This work can also be used when designing an optical imager instrument, to anticipate the dark current increase or to choose a mitigation technique.

  3. Measurement of neutron-induced activation cross-sections using spallation source at JINR and neutronic validation of the Dubna code

    Indian Academy of Sciences (India)

    Manish Sharma; V Kumar; H Kumawat; J Adam; V S Barashenkov; S Ganesan; S Golovatiouk; S K Gupta; S Kailas; M I Krivopustov; H S Palsania; V Pronskikh; V M Tsoupko-Sitnikov; N Vladimirova; H Westmeier; W Westmeier

    2007-02-01

    A beam of 1 GeV proton coming from Dubna Nuclotron colliding with a lead target surrounded by 6 cm paraffin produces spallation neutrons. A Th-foil was kept on lead target (neutron spallation source) in a direct stream of neutrons for activation and other samples of 197Au, 209Bi, 59Co, 115In and 181Ta were irradiated by moderated beam of neutrons passing through 6 cm paraffin moderator. The gamma spectra of irradiated samples were analyzed using gamma spectrometry and DEIMOS software to measure the neutron cross-section. For this purpose neutron fluence at the positions of samples is also estimated using PREPRO software. The results of cross-sections for reactions 232Th(, ), 232Th(, 2), 197Au(, ), 197Au(, ), 197Au(, ), 59Co(, ), 59Co(, ), 181Ta(, ) and 181Ta(, ) are given in this paper. Neutronics validation of the Dubna Cascade Code is also done using cross-section data by other experiments.

  4. An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

    Energy Technology Data Exchange (ETDEWEB)

    Nohtomi, Akihiro, E-mail: nohtomi@hs.med.kyushu-u.ac.jp [Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Kurihara, Ryosuke; Kinoshita, Hiroyuki; Honda, Soichiro; Tokunaga, Masaaki; Uno, Heita [Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Shinsho, Kiyomitsu [Graduate School of Human Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-oku, Arakawa-ku, Tokyo 116-8551 (Japan); Wakabayashi, Genichiro [Atomic Energy Research Institute, Kinki University, 3-4-1 Kowakae, Higashiosaka-shi, Osaka 577-8502 (Japan); Koba, Yusuke [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan); Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko [Department of Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Ohga, Saiji [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2016-10-01

    In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement. - Highlights: • Preliminary observations have been performed by a CCD for the CsI self-activation method. • It has been revealed that the CCD read-out technique is applicable to neutron measurement. • Such application may provide a novel method for simple neutron distribution measurement.

  5. Active Neutron Interrogation of Non-Radiological Materials with NMIS

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Mark E [ORNL; Mihalczo, John T [ORNL

    2012-02-01

    The Nuclear Materials Identification System (NMIS) at Oak Ridge National Laboratory (ORNL), although primarily designed for analyzing special nuclear material, is capable of identifying nonradiological materials with a wide range of measurement techniques. This report demonstrates four different measurement methods, complementary to fast-neutron imaging, which can be used for material identification: DT transmission, DT scattering, californium transmission, and active time-tagged gamma spectroscopy. Each of the four techniques was used to evaluate how these methods can be used to identify four materials: aluminum, polyethylene, graphite, and G-10 epoxy. While such measurements have been performed individually in the past, in this project, all four measurements were performed on the same set of materials. The results of these measurements agree well with predicted results. In particular, the results of the active gamma spectroscopy measurements demonstrate the technique's applicability in a future version of NMIS which will incorporate passive and active gamma-ray spectroscopy. This system, designated as a fieldable NMIS (FNMIS), is under development by the US Department of Energy Office of Nuclear Verification.

  6. Active self-testing noise measurement sensors for large-scale environmental sensor networks.

    Science.gov (United States)

    Domínguez, Federico; Cuong, Nguyen The; Reinoso, Felipe; Touhafi, Abdellah; Steenhaut, Kris

    2013-12-13

    Large-scale noise pollution sensor networks consist of hundreds of spatially distributed microphones that measure environmental noise. These networks provide historical and real-time environmental data to citizens and decision makers and are therefore a key technology to steer environmental policy. However, the high cost of certified environmental microphone sensors render large-scale environmental networks prohibitively expensive. Several environmental network projects have started using off-the-shelf low-cost microphone sensors to reduce their costs, but these sensors have higher failure rates and produce lower quality data. To offset this disadvantage, we developed a low-cost noise sensor that actively checks its condition and indirectly the integrity of the data it produces. The main design concept is to embed a 13 mm speaker in the noise sensor casing and, by regularly scheduling a frequency sweep, estimate the evolution of the microphone's frequency response over time. This paper presents our noise sensor's hardware and software design together with the results of a test deployment in a large-scale environmental network in Belgium. Our middle-range-value sensor (around €50) effectively detected all experienced malfunctions, in laboratory tests and outdoor deployments, with a few false positives. Future improvements could further lower the cost of our sensor below €10.

  7. Development of Distinction Method of Production Area of Ginsengs by Using a Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin; Chung, Yong Sam; Sun, Gwang Min; Lee, Yu Na; Yoo, Sang Ho [KAERI, Daejeon (Korea, Republic of)

    2010-05-15

    Distinction of production area of Korean ginsengs has been tried by using neutron activation techniques such as an instrumental neutron activation analysis (INAA) and a prompt gamma activation analysis (PGAA). A distribution of elements has varied according to the part of plant clue to the difference of enrichment effect and influence from a soil where the plants have been grown. So correlation study between plants and soil has been an Issue. In this study, the distribution of trace elements within a Korean ginseng was investigated by using an instrumental neutron activation analysis

  8. Investigation of distribution of elements in a Korean ginseng by using a neutron activation method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Na; Sun, Gwang Min; Chung, Yong Sam; Kim, Young Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-10-15

    The Distinction of production areas of Korean ginsengs has been tried by using neutron activation techniques such as an instrumental neutron activation analysis (INAA) and a prompt gamma activation analysis (PGAA). This study was done as a part of those efforts. As is well known, the distribution of elements varies according to the part of plant due to the difference of enrichment effect and influence from a soil where the plants have been grown. So a correlation study between plants and soil is an important issue. In this study, the distribution of trace elements within a Korean ginseng was investigated by using an instrumental neutron activation analysis.

  9. Computer programs for absolute neutron activation analysis on the nuclear data 6620 data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Wade, J.W.; Emery, J.F.

    1982-03-01

    Five computer programs that provide multielement neutron activation analysis are discussed. The software package was designed for use on the Nuclear Data 6620 Data Acquisition System and interacts with existing Nuclear Data Corporation software. The programs were developed to make use of the capabilities of the 6620 system to analyze large numbers of samples and assist in a large sample workload that had begun in the neutron activation analysis facility of the Oak Ridge Research Reactor. Nuclear Data neutron activation software is unable to perform absolute activation analysis and therefore was inefficient and inadequate for our applications.

  10. Neutron transport calculation for Activation Evaluation for Decommissioning of PET cyclotron Facility

    Science.gov (United States)

    Nobuhara, Fumiyoshi; Kuroyanagi, Makoto; Masumoto, Kazuyoshi; Nakamura, Hajime; Toyoda, Akihiro; Takahashi, Katsuhiko

    2017-09-01

    In order to evaluate the state of activation in a cyclotron facility used for the radioisotope production of PET diagnostics, we measured the neutron flux by using gold foils and TLDs. Then, the spatial distribution of neutrons and induced activity inside the cyclotron vault were simulated with the Monte Calro calculation code for neutron transport and DCHAIN-SP for activation calculation. The calculated results are in good agreement with measured values within factor 3. Therefore, the adaption of the advanced evaluation procedure for activation level is proved to be important for the planning of decommissioning of these facilities.

  11. FY16 Status Report on NEAMS Neutronics Activities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. H. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Smith, M. A. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Jung, Y. S. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2016-09-30

    The goal of the NEAMS neutronics effort is to develop a neutronics toolkit for use on sodium-cooled fast reactors (SFRs) which can be extended to other reactor types. The neutronics toolkit includes the high-fidelity deterministic neutron transport code PROTEUS and many supporting tools such as a cross section generation code MC2-3, a cross section library generation code, alternative cross section generation tools, mesh generation and conversion utilities, and an automated regression test tool. The FY16 effort for NEAMS neutronics focused on supporting the release of the SHARP toolkit and existing and new users, continuing to develop PROTEUS functions necessary for performance improvement as well as the SHARP release, verifying PROTEUS against available existing benchmark problems, and developing new benchmark problems as needed. The FY16 research effort was focused on further updates of PROTEUS-SN and PROTEUS-MOCEX and cross section generation capabilities as needed.

  12. Calculation of thermal neutron self-shielding correction factors for aqueous bulk sample prompt gamma neutron activation analysis using the MCNP code

    Energy Technology Data Exchange (ETDEWEB)

    Nasrabadi, M.N. [Department of Physics, Faculty of Science, University of Kashan, Km. 6, Ravand Road, Kashan (Iran, Islamic Republic of)], E-mail: mnnasri@kashanu.ac.ir; Jalali, M. [Isfahan Nuclear Science and Technology Research Institute, Atomic Energy organization of Iran (Iran, Islamic Republic of); Mohammadi, A. [Department of Physics, Faculty of Science, University of Kashan, Km. 6, Ravand Road, Kashan (Iran, Islamic Republic of)

    2007-10-15

    In this work thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing materials is studied using bulk sample prompt gamma neutron activation analysis (BSPGNAA) with the MCNP code. The code was used to perform three dimensional simulations of a neutron source, neutron detector and sample of various material compositions. The MCNP model was validated against experimental measurements of the neutron flux performed using a BF{sub 3} detector. Simulations were performed to predict thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing solutes. In practice, the MCNP calculations are combined with experimental measurements of the relative thermal neutron flux over the sample's surface, with respect to a reference water sample, to derive the thermal neutron self-shielding within the sample. The proposed methodology can be used for the determination of the elemental concentration of unknown aqueous samples by BSPGNAA where knowledge of the average thermal neutron flux within the sample volume is required.

  13. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G.D.; Smallwood, A. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  14. Development of active environmental and personal neutron dosemeters.

    Science.gov (United States)

    Nakamura, T; Nunomiya, T; Sasaki, M

    2004-01-01

    For neutron dosimetry in the radiation environment surrounding nuclear facilities, two types of environmental neutron dosemeters, the high-sensitivity rem counter and the high-sensitivity multi-moderator, the so-called Bonner ball, have been developed and the former is commercially available from Fuji Electric Co. By using these detectors, the cosmic ray neutrons at sea level have been sequentially measured for about 3 y to investigate the time variation of neutron spectrum and ambient dose equivalent influenced by cosmic and terrestrial effects. Our Bonner ball has also been selected as the neutron detector in the International Space Station and has already been used to measure neutrons in the US experimental module. The real time wide-range personal neutron dosemeter which uses two silicon semiconductor detectors has been developed for personal dosimetry and is commercially available from Fuji Electric Co. This dosemeter has good characteristics, fitted to the fluence-to-dose conversion factor in the energy range from thermal energies to several tens of mega-electron-volts and is now widely used in various nuclear facilities.

  15. Characteristics of SiC neutron sensor spectrum unfolding process based on Bayesian inference

    Energy Technology Data Exchange (ETDEWEB)

    Cetnar, Jerzy; Krolikowski, Igor [Faculty of Energy and Fuels AGH - University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow (Poland); Ottaviani, L. [IM2NP, UMR CNRS 7334, Aix-Marseille University, Case 231 -13397 Marseille Cedex 20 (France); Lyoussi, A. [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France)

    2015-07-01

    This paper deals with SiC detector signal interpretation in neutron radiation measurements in mixed neutron gamma radiation fields, which is called the detector inverse problem or the spectrum unfolding, and it aims in finding a representation of the primary radiation, based on the measured detector signals. In our novel methodology we resort to Bayesian inference approach. In the developed procedure the resultant spectra is unfolded form detector channels reading, where the estimated neutron fluence in a group structure is obtained with its statistical characteristic comprising of standard deviation and correlation matrix. In the paper we present results of unfolding process for case of D-T neutron source in neutron moderating environment. Discussions of statistical properties of obtained results are presented as well as of the physical meaning of obtained correlation matrix of estimated group fluence. The presented works has been carried out within the I-SMART project, which is part of the KIC InnoEnergy R and D program. (authors)

  16. Integrated active sensor system for real time vibration monitoring.

    Science.gov (United States)

    Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue

    2015-11-05

    We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0-60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems.

  17. Activation analysis of indium, KCl, and melamine by using a laser-induced neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sungman; Lee, Kitae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cha, Hyungki [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2014-04-15

    A laser-induced repetitively operated fast neutron source with a neutron yield of 4 x 10{sup 5} n/pulse and a pulse repetition rate of 5 Hz, which was developed using a deuterated polystyrene film target and a 24-TW femtosecond laser, was applied for laser activation analyses of indium, KCl, and melamine samples. The nuclear reactions of the measured gamma spectra for the activated samples were identified as (n, γ), (n, n'), and (n, 2n) reactions. These indicate possible usage of the neutron source for practical activation analyses of various materials.

  18. Active Self-Testing Noise Measurement Sensors for Large-Scale Environmental Sensor Networks

    Directory of Open Access Journals (Sweden)

    Federico Domínguez

    2013-12-01

    Full Text Available Large-scale noise pollution sensor networks consist of hundreds of spatially distributed microphones that measure environmental noise. These networks provide historical and real-time environmental data to citizens and decision makers and are therefore a key technology to steer environmental policy. However, the high cost of certified environmental microphone sensors render large-scale environmental networks prohibitively expensive. Several environmental network projects have started using off-the-shelf low-cost microphone sensors to reduce their costs, but these sensors have higher failure rates and produce lower quality data. To offset this disadvantage, we developed a low-cost noise sensor that actively checks its condition and indirectly the integrity of the data it produces. The main design concept is to embed a 13 mm speaker in the noise sensor casing and, by regularly scheduling a frequency sweep, estimate the evolution of the microphone’s frequency response over time. This paper presents our noise sensor’s hardware and software design together with the results of a test deployment in a large-scale environmental network in Belgium. Our middle-range-value sensor (around €50 effectively detected all experienced malfunctions, in laboratory tests and outdoor deployments, with a few false positives. Future improvements could further lower the cost of our sensor below €10.

  19. In-situ soil composition and moisture measurement by surface neutron activation analysis

    Science.gov (United States)

    Waring, C.; Smith, C.; Marks, A.

    2009-04-01

    Neutron activation analysis is widely known as a laboratory technique dependent upon a nuclear reactor to provide the neutron flux and capable of precise elemental analysis. Less well known in-situ geochemical analysis is possible with isotopic (252Cf & 241Am) or compact accelerator (D-T, D-D fusion reaction) neutron sources. Prompt gamma neutron activation analysis (PGNAA) geophysical borehole logging has been applied to mining issues for >15 years (CSIRO) using isotopic neutron sources and more recently to environmental and hydro-geological applications by ANSTO. Similarly, sophisticated geophysical borehole logging equipment based on inelastic neutron scattering (INS) has been applied in the oil and gas industry by large oilfield services companies to measure oil saturation indices (carbon/oxygen) using accelerator neutron sources. Recent advances in scintillation detector spectral performance has enabled improved precision and detection limits for elements likely to be present in soil profiles (H, Si, Al, Fe, Cl) and possible detection of many minor to trace elements if sufficiently abundant (Na, K, Mg, Ca, S, N, + ). To measure carbon an accelerator neutron source is required to provide fast neutrons above 4.8 MeV. CSIRO and ANSTO propose building a soil geochemical analysis system based on experience gained from building and applying PGNA borehole logging equipment. A soil geochemical analysis system could effectively map the 2D geochemical composition of the top 50cm of soil by dragging the 1D logging equipment across the ground surface. Substituting an isotopic neutron source for a D-T accelerator neutron source would enable the additional measurement of elemental carbon. Many potential ambiguities with other geophysical proxies for soil moisture may be resolved by direct geochemical measurement of H. Many other applications may be possible including time series in-situ measurements of soil moisture for differential drainage, hydrology, land surface

  20. Two non-destructive neutron inspection techniques: prompt gamma-ray activation analysis and cold neutron tomography

    OpenAIRE

    Baechler, Sébastien; Dousse, Jean-Claude; Jolie, Jan

    2005-01-01

    Deux techniques d’inspection non-destructives utilisant des faisceaux de neutrons froids ont été développées à la source de neutrons SINQ de l’Institut Paul Scherrer : (1) l’analyse par activation neutronique prompte (PGAA) et (2) la tomographie neutronique. L’analyse par PGA (Prompt Gamma-ray Activation) est une méthode nucléaire qui permet de déterminer la concentration d’éléments présents dans un échantillon. Cette technique consiste à détecter les rayons gamma prompts émis par l’échantill...

  1. Recognizing Multi-user Activities using Body Sensor Networks

    DEFF Research Database (Denmark)

    Gu, Tao; Wang, Liang; Chen, Hanhua

    2011-01-01

    The advances of wireless networking and sensor technology open up an interesting opportunity to infer human activities in a smart home environment. Existing work in this paradigm focuses mainly on recognizing activities of a single user. In this work, we address the fundamental problem...... activity classes of data—for building activity models and design a scalable, noise-resistant, Emerging Pattern based Multi-user Activity Recognizer (epMAR) to recognize both single- and multi-user activities. We develop a multi-modal, wireless body sensor network for collecting real-world traces in a smart...... of recognizing activities of multiple users using a wireless body sensor network, and propose a scalable pattern mining approach to recognize both single- and multi-user activities in a unified framework. We exploit Emerging Pattern—a discriminative knowledge pattern which describes significant changes among...

  2. Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.

    Directory of Open Access Journals (Sweden)

    Shinsuke Nakayama

    Full Text Available This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG. The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.

  3. Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.

    Science.gov (United States)

    Nakayama, Shinsuke; Sawamura, Kenta; Mohri, Kaneo; Uchiyama, Tsuyoshi

    2011-01-01

    This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI) sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT) level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG). The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.

  4. Essential trace elements in edible mushrooms by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Patricia L.C.; Maihara, Vera A.; Castro, Lilian P. de [Instituto de Pesquisa e Energetica e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: patricialandim@ig.com.br; vmaihara@ipen.br; lilian.Pavanelli@terra.com.br; Figueira, Rubens C.L. [Universidade Cruzeiro do Sul, Sao Paulo, SP (Brazil)]. E-mail: figueiraru@yahoo.com.br

    2007-07-01

    Mushrooms are excellent nutritional sources since they provide proteins, fibers and mineral, such as K, P, Fe. They have also been the focus of medical research. In Brazil mushrooms are not consumed in large quantities by the general population since people know little about the nutritional and medicinal benefits that mushrooms offer. Hence, this study intends to contribute to a better understanding of the essential element content in edible mushrooms, which are currently commercialized in Sao Paulo state. Br Fe, K, Na and Zn concentrations were determined by Instrumental Neutron Activation Analysis in the following mushroom species: Shitake (Lentinus edodes), Shimeji (Pleurotus ssp), Paris Champignon (Agaricus bisporus), Hiratake ( Pleurotus ssp) and Eringue (Pleurotus Eryngu. The mushroom samples were acquired from commercial establishments in the city of Sao Paulo and directly from the producers. Essential element contents in mushrooms varied between Br 0.03 to 4.1 mg/kg; Fe 20 to 267 mg/kg; K 1.2 to 5.3 g/kg, Na 10 to 582 mg/kg and Zn 60 to 120 mg/kg. The results confirm that mushrooms can be considered a good source of K, Fe and Zn. The low Na level is a good nutritional benefit for the consumer. (author)

  5. Elementary concentration of Peruibe black mud by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Torrecilha, Jefferson K.; Ponciano, Ricardo; Silva, Paulo S.C da, E-mail: jeffkoy@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The Peruibe Black Mud is used in therapies such as psoriasis, peripheral dermatitis, acne, seborrehea, myalgia arthritis and rheumatic non-articular processes. This material is characterized by is fine organic matter particles, sulphate reducing bacteria and a high content of potential reduction ions. Although this material is particles, sulphate reducing bacteria and a high content of potential reduction ions. Although this material is considered natural, it may not be free of possible adverse health effects, like toxic chemical elements, when used for therapeutic purposes. In the therapeutic treatments involving clays, clays are used in mud form also called peloids, obtained by maturation process. Five in natura and three maturated Black Mud samples were collected in Peruibe city, Sao Paulo State, Brazil. To investigate the distribution of major, trace and rare earth elements in the in natura and maturated clays that constitute the Peruibe Black Mud, neutron activation analysis (NAA) was used. A comparison between in natura and maturated mud shows that major, trace and rare earth elements follow the same order in both types. Generally, the concentrations in the maturated mud are slightly lower than in natura mud. Enrichment on the upper continental crust could be observed for the elements As, Br, Sb and Se, in these types of mud. (author)

  6. Neutron activation analysis and provenance study of Tupiguarani Tradition pottery

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Gleikam Lopes de Oliveira [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/ CNEN-MG), Belo Horizonte, MG (Brazil). Curso de Mestrado em Ciencia e Tecnologia das Radiacoes, Minerais e Materiais], e-mail: gleikam@yahoo.com.br; Menezes, Maria Angela de B.C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/ CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Reator e Tecnicas Analiticas. Lab. de Ativacao Neutronica], e-mail: menezes@cdtn.br; Ribeiro, Loredana; Jacome, Camila [Cooperativa dos Empreendedores em Acoes Culturais - COOP. CULTURA, Belo Horizonte, MG (Brazil). Lab. de Arqueologia], e-mail: loredana.ribeiro@gmail.com

    2009-07-01

    Archaeology can fill the gap between ancient population and modern society elucidating the evidences found in archaeological sites. The fingerprint identified, that is the chemical composition of the ceramics, can help understanding this connection between the past and the present. The Tupiguarani Tradition vestiges found by archaeologists will be a way to know about the last two millennia of the Brazilian prehistory. This archaeological site is located along the coast of the Brazilian State of Espirito Santo, where the main evidence is a pretty ceramic with the occurrence of plastic and painted decoration. When the Portuguese settlers arrived in this region, in sixteenth century, several Missoes Jesuiticas (Jesuitical Missions) were built along the Brazilian coast. In spite of living within the Mission and been catechized, the Indians kept on producing traditional handicraft, as the decorated ceramic, however, they introduced European elements to the decoration. During the research expeditions made to the archaeological site of the Tupiguarani Tradition, many sherds were found. The identification and classification of ceramics through a multielemental chemistry analysis will be used to determine if they have the same origin. This paper shows the first elemental concentration results of the sherds collected from archaeological site determined at CDTN/CNEN, Belo Horizonte, Minas Gerais, using the TRIGA Mark I IPR-R1 nuclear reactor, applying the neutron activation technique, k{sub 0}-method. (author)

  7. Inorganic constituents in herbal medicine by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Rodolfo D.M.R.; Francisconi, Lucilaine S.; Silva, Paulo S.C. da, E-mail: pscsilva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN- SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The demand for herbal medicines is growing worldwide. The expansion of interest has required the standardization of the sector with implementation and constant review of technical standards for production and marketing of these medicines in order to ensure the safe use, therapeutic efficacy and quality of the products. According to data from the World Health Organization, approximately 80% of world population has resorted to the benefits of certain herbs with therapeutic action popularly recognized. Despite the vast flora and the extensive use of medicinal plants by the population, it is a consensus that scientific studies on the subject are insufficiency. Therefore, it is necessary to stimulate such studies in view of the importance of the results of both individual and social field. The determination of major, minor and trace elements and the research of metabolic processes and their impacts on human health are of great importance due to the growth of environmental pollution that directly affects the plants and therefore the phytotherapics. Therefore, the objective of this work was to determine the content of inorganic constituents in herbal medicine: moisture, total ash and the elements As, Ba, Br, Ca, Cs, Co, Cr, Fe, Hf, K, Na, Rb, Sb, Sc, Se, Ta, Th, U, Zn and Zr by neutron activation analysis in order to verify the quality of the products. It was observed that the elemental concentrations varied in a wide range from plant to plant and elements with higher concentrations were Ba, Fe, Cr and Zn. (author)

  8. Response of thunderstorm activity in data of neutron monitoring at Tien Shan

    Science.gov (United States)

    Antonova, Valentina; Kryukov, Sergey; Lutsenko, Vadim

    2015-04-01

    We present results of the study of data of the monitoring of high-energy and thermal neutrons at Tien Shan at different stages of thunderstorm activity. The data of the neutron monitoring were used taking into account the barometric effect. The intensity of the neutron component of cosmic rays is recorded in seven energy ranges. The electric field has values of ~ 100 V/m under fair weather conditions. Standard deviation of minute values of the neutron monitor data at the high altitude station does not exceed 0.5-0.6 %. Found that the standard deviation of the data during thunderstorms always exceeds these values. We selected events during the passage of thunderstorm clouds over the high altitude station without lightning discharges or with a small number of them. It was found that the particle rate of the neutron monitor changes in antiphase with the electric field changes. Atmospheric electric field of positive polarity decreases the count rate of the neutron monitor, and negative polarity - increases. Change of the count rate occurs at values of electric field ≥ 10-15 kV/m and reaches 2 %. The neutron monitor at the high-altitude station has the ability to measure the energy of recorded particles through determination of their multiplicity. We experimentally established that the sensitivity of the detected particles to change in Ez increases with decreasing their energy. The upper energy threshold of sensitivity of neutrons to change electric field is ~10 GeV. The physical mechanism of effect is based on lead nucleus capture of soft negative muons with the subsequent generation of neutrons. It is known that 7% of the neutron monitor count rate caused by negative muons. Absence of this effect in thermal neutrons data confirms the conclusion since the main difference of the thermal neutrons detector from the neutron monitor is the absence of the lead. In the active phase of a thunderstorm in the formed thundercloud the picture of distribution of charges is

  9. The Sandia MEMS passive shock sensor : FY07 maturation activities.

    Energy Technology Data Exchange (ETDEWEB)

    Houston, Jack E.; Blecke, Jill; Mitchell, John Anthony; Wittwer, Jonathan W.; Crowson, Douglas A.; Clemens, Rebecca C.; Walraven, Jeremy Allen; Epp, David S.; Baker, Michael Sean

    2008-08-01

    This report describes activities conducted in FY07 to mature the MEMS passive shock sensor. The first chapter of the report provides motivation and background on activities that are described in detail in later chapters. The second chapter discusses concepts that are important for integrating the MEMS passive shock sensor into a system. Following these two introductory chapters, the report details modeling and design efforts, packaging, failure analysis and testing and validation. At the end of FY07, the MEMS passive shock sensor was at TRL 4.

  10. Human psychophysiological activity monitoring methods using fiber optic sensors

    Science.gov (United States)

    Zyczkowski, M.; Uzieblo-Zyczkowska, B.

    2010-10-01

    The paper presents the concept of fiber optic sensor system for human psycho-physical activity detection. A fiber optic sensor that utilizes optical phase interferometry or intensity in modalmetric to monitor a patient's vital signs such as respiration cardiac activity, blood pressure and body's physical movements. The sensor, which is non-invasive, comprises an optical fiber interferometer that includes an optical fiber proximately situated to the patient so that time varying acusto-mechanical signals from the patient are coupled into the optical fiber. The system can be implemented in embodiments ranging form a low cost in-home to a high end product for in hospital use.

  11. Characteristics and application of spherical-type activation detectors in neutron spectrum measurements at a boron neutron capture therapy (BNCT) facility

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Heng-Xiao; Chen, Wei-Lin [Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 300, Taiwan, ROC (China); Liu, Yuan-Hao [Neuboron Medtech Ltd., Nanjing, Jiangsu Province 21112 (China); Sheu, Rong-Jiun, E-mail: rjsheu@mx.nthu.edu.tw [Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 300, Taiwan, ROC (China); Department of Engineering and System Science, National Tsing Hua University, Hsinchu 300, Taiwan, ROC (China)

    2016-03-01

    A set of spherical-type activation detectors was developed aiming to provide better determination of the neutron spectrum at the Tsing Hua Open-pool Reactor (THOR) BNCT facility. An activation foil embedded in a specially designed spherical holder exhibits three advantages: (1) minimizing the effect of neutron angular dependence, (2) creating response functions with broadened coverage of neutron energies by introducing additional moderators or absorbers to the central activation foil, and (3) reducing irradiation time because of improved detection efficiencies to epithermal neutron beam. This paper presents the design concept and the calculated response functions of new detectors. Theoretical and experimental demonstrations of the performance of the detectors are provided through comparisons of the unfolded neutron spectra determined using this method and conventional multiple-foil activation techniques.

  12. Present and Future Activities on Neutron Imaging in Argentina

    Science.gov (United States)

    Tartaglione, Aureliano; Blostein, Jerónimo; Cantargi, Florencia; Marín, Julio; Baruj, Alberto; Meyer, Gabriel; Santisteban, Javier; Sánchez, Fernando

    We present here a short review of the main work which has been done in the latest years in neutron imaging in Argentina, and the future plans for the development of this technique in the country, mainly focused in the design of a new neutron imaging instrument to be installed in the future research reactor RA10. We present here the results of the implementation of the technique in samples belonging to the Argentinean cultural heritage and experiments related with hydrogen storage. At the same time, the Argentinean RA10 project for the design and construction of a 30 MW multipurpose research reactor is rapidly progressing. It started to be designed by the National Atomic Energy Commission (CNEA) and the technology company INVAP SE, both from Argentina, in June 2010. The construction will start in the beginning of 2015 in the Ezeiza Atomic Center, at 36 km from Buenos Aires City, and is expected to be finished by 2020. One of the main aims of the project is to offer to the Argentinean scientific and technology system new capabilities based on neutron techniques. We present here the conceptual design of a neutron imaging facility which will use one of the cold neutron beams, and will be installed in the reactor hall. Preliminary simulation results show that at the farthest detection position, at about 17 m from the cold source, a uniform neutron beam on a detection screen with an intensity of about 108 n/cm2/s is expected.

  13. Molecular detection by active Fano-sensor

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Yifei; Guo, Zhongyi [School of Computer and Information, Hefei University of Technology, Hefei, 230009 (China)

    2017-04-15

    The optical properties and sensing performances of the molecular sensors based on plasmonic Fano-resonance (PFR) nanostructures have been numerically investigated in detail. The on-resonance sensor, in which the Fano-resonance position is overlapping with the absorption-band of the detected molecules perfectly, reveals a powerful ability to detect the molecules with a low concentration or thin thickness. By the bias-modulation of a single-layer graphene, the Fano-resonance position of the nanostructures can be tuned effectively. On being modulated properly, the PFR sensor shows an ultrahigh performance because of the unprecedentedly high overlap of the Fano-resonance position with the absorption-band of molecules, which is enabling superior signal strength in the molecular detections based on their vibrational fingerprints. Our proposed strategy may enable the development of dynamic sensors and open exciting prospects for bio-sensing. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  14. Praseodymium activation detector for measuring bursts of 14 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Meehan, Tim, E-mail: meehanbt@nv.doe.go [National Security Technologies, LLC, P.O. Box 98521, North Las Vegas, NV 89030 (United States); Hagen, E.C. [National Security Technologies, LLC, P.O. Box 98521, North Las Vegas, NV 89030 (United States); Ruiz, C.L.; Cooper, G.W. [Sandia National Laboratories, P.O. Box 5800, Albuquerque, NM 87185 (United States)

    2010-08-21

    A new, accurate, neutron activation detection scheme for measuring pulsed neutrons has been designed and tested. The detection system is sensitive to neutrons with energies above 10 MeV; importantly, it is insensitive to gamma radiation <10 MeV and to lower-energy (e.g., fission and thermal) neutrons. It is based upon the use of {sup 141}Pr, an element that has a single, naturally occurring isotope, a significant n,2n cross-section, and decays by positron emission that result in two coincident 511 keV photons. Neutron fluences are thus inferred by relating measured reaction product decay activity to fluence. Specific sample activity is measured using the sum-peak method to count gamma-ray coincidences from the annihilation of the positron decay products. The system was tested using 14 and 2.45 MeV neutron bursts produced by NSTec Dense Plasma Focus Laboratory fusion sources. Lead, copper, beryllium, and silver activation detectors were compared. The detection method allows measurement of 14 MeV neutron yield with a total error of {approx}18%.

  15. Feasibility study of a neutron activation system for EU test blanket systems

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Kuo, E-mail: kuo.tian@kit.edu [Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Calderoni, Pattrick [Fusion for Energy(F4E), Barcelona (Spain); Ghidersa, Bradut-Eugen; Klix, Axel [Institute for Neutron Physics and Reactor Technology, Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany)

    2016-11-01

    Highlights: • This paper summarizes the technical baseline and preliminary design of EU TBM Neutron Activation System, briefly describes the key components, and outlines the major integration challenges. - Abstract: The Neutron Activation System (NAS) for the EU Helium Cooled Lithium Lead (HCLL) and Helium Cooled Pebble Bed (HCPB) Test Blanket Systems (TBSs) is an instrument that is proposed to determine the absolute neutron fluence and absolute neutron flux with information on the neutron spectrum in selected positions of the corresponding Test Blanket Modules (TBMs). In the NAS activation probes are exposed to the ITER neutron flux for periods ranging from several tens of seconds up to a full plasma pulse length, and the induced gamma activities are subsequently measured. The NAS is composed of a pneumatic transfer system and a counting station. The pneumatic transfer system includes irradiation ends in TBMs, transfer pipes, return gas pipes, a transfer station with a distributor (carousel), and a pressurized gas driving system, while the counting station consists of gamma ray detectors, signal processing electronic devices, and data analyzing software for neutron source strength evaluation. In this paper, a brief description on the proposed TBM NAS as well as the key components is presented, and the integration challenges of TBM NAS are outlined.

  16. Dosimetric optimization of postproduction neutron-activated Erbium-170-oxide-enriched pancreatin

    Energy Technology Data Exchange (ETDEWEB)

    Borm, J.J.J.; Bruno, M.J.; Goeij, J.J.M. de [Academic Medical Center, Amsterdam (Netherlands)]|[Delft Univ. of Technology, Mekelweg (Netherlands)]|[Nordmark Arzneimittel GmbH, Uetersen (Germany)] [and others

    1995-05-01

    The feasibility of postproduction neutron activation of an enteric-coated pancreatic enzyme preparation for in vivo gastric emptying studies has been investigated. During production of this multicomponent preparation, small amounts of {sup 170}Er-enriched erbium oxide, suitable for neutron activation, were added. Postproduction neutron irradiation of the labeled preparation resulted in short-lived (7.5 hr) gamma-emitting {sup 171}Er. Various radiocontaminants, however, are produced also. Because of variations in activation yields, half-lives, decay schemes and radiotoxicities, both major and trace consitituents were considered for optimization of both dosimetry and the diagnostic measurement. Conditions were optimized for the best ratio of the committed dose equivalent due to {sup 171}Er to the total committed dose equivalent. The results show that postproduction neutron activation of a {sup 170}Er-enriched multicomponent preparation can be performed safely within the guidelines set by the WHO for experiments in humans involving radioactive materials. 9 refs., 3 tabs.

  17. Estimates of iodine in biological materials by epithermal neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T. (Tokyo Metropolitan Inst. for Neurosciences, Fuchu (Japan)); Kato, T. (Tohoku Univ., Sendai (Japan). Coll. of General Education)

    1982-01-01

    Iodine abundances in NBS biological SRMs and various organs of rats were evaluated by epithermal neutron activation analysis with a boron carbide filter. The detectability of iodine in different biological materials by this method is discussed.

  18. Neutrons formed by heavy ions and activation induced in different materials; Neutrons crees par ions lourds et activation induite dans divers materiaux

    Energy Technology Data Exchange (ETDEWEB)

    Clapier, F.; Pauwels, N.; Proust, J.

    1995-12-31

    This work deals with the Spiral project and more particularly with the neutrons flux formed by heavy ions and the activation induced in different materials. Indeed, the beams power suggests the interest of different materials behaviour study for allowing a possible selection to optimize radioprotection. Moreover, it is important to establish the activation mechanisms in order to be able to extrapolate the measures realized at 400 W (actual GANIL) to those of the future running taking into account the radioisotopes real mixtures formed during the reaction and their daughter products. A best knowledge of energizing and angular neutrons distributions is searched too. (O.L.). 11 refs., 23 figs., 9 tabs.

  19. Neutron induced background gamma activity in low-level Ge-spectroscopy systems

    Science.gov (United States)

    Jovančević, N.; Krmar, M.; Mrda, D.; Slivka, J.; Bikit, I.

    2010-01-01

    Two high purity germanium (HPGe) detectors were located in two different passive shields: one in pre-WW II iron and the second in commercial low background lead. Gamma lines emitted after neutron capture, as well as after inelastic scattering on the germanium crystal were detected and then analyzed. The thermal and fast neutron fluxes were calculated and their values were compared for the two different kinds of detector shield. Several materials having different neutron slowing-down properties were packed in Marinelli geometry, positioned on the lead shielded detector and measured for around 10 6 s. The main goal was to estimate a possible influence of the sample on the intensity of the neutron induced Ge gamma lines. On the iron-shielded detector a massive (3 in. thick) NaI Compton suppression system showed a measurable activity from neutron capture and inelastic scattering on sodium and iodine nuclei.

  20. Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Fissionable Material

    Energy Technology Data Exchange (ETDEWEB)

    D. L. Chichester; E. H. Seabury

    2008-10-01

    Experiments have been performed at Idaho National Laboratory to study methodology and instrumentation for performing neutron active interrogation die-away analyses for the purpose of detecting shielded fissionable material. Here we report initial work using a portable DT electronic neutron generator with a He-3 fast neutron detector to detect shielded fissionable material including >2 kg quantities of enriched uranium and plutonium. Measurements have been taken of bare material as well as of material hidden within a large plywood cube. Results from this work have demonstrated the efficacy of the die-away neutron measurement technique for quickly detecting the presence of special nuclear material hidden within plywood shields by analyzing the time dependent neutron signals in-between neutron generator pulses. Using a DT electronic neutron generator operating at 300 Hz with a yield of approximately 0.36 x 10**8 neutrons per second, 2.2 kg of enriched uranium hidden within a 0.60 m x 0.60 m x 0.70 m volume of plywood was positively detected with a measurement signal 2-sigma above the passive background within 1 second. Similarly, for a 500 second measurement period a lower detection limit of approaching the gram level could be expected with the same simple set-up.

  1. The Monte Carlo code CSSE for the simulation of realistic thermal neutron sensor devices for Humanitarian Demining

    Energy Technology Data Exchange (ETDEWEB)

    Palomba, M. E-mail: maurizio.palomba@ba.infn.it; D' Erasmo, G.; Pantaleo, A

    2003-02-11

    The CSSE code, a GEANT3-based Monte Carlo simulation program, has been developed in the framework of the EXPLODET project (Nucl. Instr. and Meth. A 422 (1999) 918) with the aim to simulate experimental set-ups employed in Thermal Neutron Analysis (TNA) for the landmines detection. Such a simulation code appears to be useful for studying the background in the {gamma}-ray spectra obtained with this technique, especially in the region where one expects to find the explosive signature (the {gamma}-ray peak at 10.83 MeV coming from neutron capture by nitrogen). The main features of the CSSE code are introduced and original innovations emphasized. Among the latter, an algorithm simulating the time correlation between primary particles, according with their time distributions is presented. Such a correlation is not usually achievable within standard GEANT-based codes and allows to reproduce some important phenomena, as the pulse pile-up inside the NaI(Tl) {gamma}-ray detector employed, producing a more realistic detector response simulation. CSSE has been successfully tested by reproducing a real nuclear sensor prototype assembled at the Physics Department of Bari University.

  2. The Monte Carlo code CSSE for the simulation of realistic thermal neutron sensor devices for Humanitarian Demining

    Science.gov (United States)

    Palomba, M.; D'Erasmo, G.; Pantaleo, A.

    2003-02-01

    The CSSE code, a GEANT3-based Monte Carlo simulation program, has been developed in the framework of the EXPLODET project (Nucl. Instr. and Meth. A 422 (1999) 918) with the aim to simulate experimental set-ups employed in Thermal Neutron Analysis (TNA) for the landmines detection. Such a simulation code appears to be useful for studying the background in the γ-ray spectra obtained with this technique, especially in the region where one expects to find the explosive signature (the γ-ray peak at 10.83 MeV coming from neutron capture by nitrogen). The main features of the CSSE code are introduced and original innovations emphasized. Among the latter, an algorithm simulating the time correlation between primary particles, according with their time distributions is presented. Such a correlation is not usually achievable within standard GEANT-based codes and allows to reproduce some important phenomena, as the pulse pile-up inside the NaI(Tl) γ-ray detector employed, producing a more realistic detector response simulation. CSSE has been successfully tested by reproducing a real nuclear sensor prototype assembled at the Physics Department of Bari University.

  3. Dosimétrie électronique et métrologie neutrons par capteur CMOS a pixels actifs

    OpenAIRE

    Vanstalle, Marie

    2011-01-01

    This work aims at demonstrating the possibility to use active pixel sensors as operational neutron dosemeters. To do so, the sensor that has been used has to be γ-transparent and to be able to detect neutrons on a wide energy range with a high detection efficiency. The response of the device, made of the CMOS sensor MIMOSA-5 and a converter in front of the sen-sor (polyethylen for fast neutron detection and 10B for thermal neutron detection), has been compared with Monte Carlo simulations car...

  4. SWAN - Detection of explosives by means of fast neutron activation analysis

    Science.gov (United States)

    Gierlik, M.; Borsuk, S.; Guzik, Z.; Iwanowska, J.; Kaźmierczak, Ł.; Korolczuk, S.; Kozłowski, T.; Krakowski, T.; Marcinkowski, R.; Swiderski, L.; Szeptycka, M.; Szewiński, J.; Urban, A.

    2016-10-01

    In this work we report on SWAN, the experimental, portable device for explosives detection. The device was created as part of the EU Structural Funds Project "Accelerators & Detectors" (POIG.01.01.02-14-012/08-00), with the goal to increase beneficiary's expertise and competencies in the field of neutron activation analysis. Previous experiences and budged limitations lead toward a less advanced design based on fast neutron interactions and unsophisticated data analysis with the emphasis on the latest gamma detection and spectrometry solutions. The final device has been designed as a portable, fast neutron activation analyzer, with the software optimized for detection of carbon, nitrogen and oxygen. SWAN's performance in the role of explosives detector is elaborated in this paper. We demonstrate that the unique features offered by neutron activation analysis might not be impressive enough when confronted with practical demands and expectations of a generic homeland security customer.

  5. Electro-active material (EAM) based bend sensors

    Science.gov (United States)

    LaComb, Ronald; LaComb, Julie

    2010-04-01

    The capability to accurately estimate strain and orientation of cables in an undersea environment is important for a multitude of applications. One way to estimate the positional location of a submersed cable is to utilize a network of distributed bend sensors providing inputs to a curve fitting algorithm. In this work commercially available bend sensors are characterized for small deflections. In addition proto-type devices are presented which can potentially improve device sensitivity. Commercially available bend sensors are based upon electro-active materials and variable resistance materials. Electro-active materials (EAM) are known for their actuator functionality but certain EAMs are capable of sensing as well. New advances in materials such as Ionic Polymer Metal Composites (IPMC) are proving suitable for quasi-static sensor applications. These sensors are low power, conformal and produce directionally dependent output voltages which are linearly proportional to deflection, with voltage polarity representative of the deflection direction. IPMCs are capable of being morphed for increased sensitivity. Variable resistivity sensors are based on smart epoxy polymer and carbon loaded inks. These sensors are inexpensive and conformal and unlike EAMs provide static measurements.

  6. Sensor fusion methods for high performance active vibration isolation systems

    Science.gov (United States)

    Collette, C.; Matichard, F.

    2015-04-01

    Sensor noise often limits the performance of active vibration isolation systems. Inertial sensors used in such systems can be selected through a wide variety of instrument noise and size characteristics. However, the most sensitive instruments are often the biggest and the heaviest. Consequently, high-performance active isolators sometimes embed many tens of kilograms in instrumentation. The weight and size of instrumentation can add unwanted constraint on the design. It tends to lower the structures natural frequencies and reduces the collocation between sensors and actuators. Both effects tend to reduce feedback control performance and stability. This paper discusses sensor fusion techniques that can be used in order to increase the control bandwidth (and/or the stability). For this, the low noise inertial instrument signal dominates the fusion at low frequency to provide vibration isolation. Other types of sensors (relative motion, smaller but noisier inertial, or force sensors) are used at higher frequencies to increase stability. Several sensor fusion configurations are studied. The paper shows the improvement that can be expected for several case studies including a rigid equipment, a flexible equipment, and a flexible equipment mounted on a flexible support structure.

  7. Active Multimodal Sensor System for Target Recognition and Tracking.

    Science.gov (United States)

    Qu, Yufu; Zhang, Guirong; Zou, Zhaofan; Liu, Ziyue; Mao, Jiansen

    2017-06-28

    High accuracy target recognition and tracking systems using a single sensor or a passive multisensor set are susceptible to external interferences and exhibit environmental dependencies. These difficulties stem mainly from limitations to the available imaging frequency bands, and a general lack of coherent diversity of the available target-related data. This paper proposes an active multimodal sensor system for target recognition and tracking, consisting of a visible, an infrared, and a hyperspectral sensor. The system makes full use of its multisensor information collection abilities; furthermore, it can actively control different sensors to collect additional data, according to the needs of the real-time target recognition and tracking processes. This level of integration between hardware collection control and data processing is experimentally shown to effectively improve the accuracy and robustness of the target recognition and tracking system.

  8. Evaluation of the neutron activation of JET in-vessel components following DT irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Vuolo, M.; Bonifetto, R.; Dulla, S. [Dipartimento Energia, Politecnico di Torino, I-10129 Torino (Italy); Heinola, K. [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Association EURATOM-TEKES, University of Helsinki, PO Box 64, 00560 Helsinki (Finland); Lengar, I. [Association EURATOM-MESCS, Reactor Physics Division, Jožef Stefan Institute, Ljubljana (Slovenia); Ravetto, P., E-mail: piero.ravetto@polito.it [Dipartimento Energia, Politecnico di Torino, I-10129 Torino (Italy); Richard, L.Savoldi [Dipartimento Energia, Politecnico di Torino, I-10129 Torino (Italy); Villari, R. [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Widdowson, A. [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Zanino, R. [Dipartimento Energia, Politecnico di Torino, I-10129 Torino (Italy)

    2014-10-15

    Highlights: The temporal evolution of the radioactive species in the in-vessel components after the end of the JET-DT campaign is calculated; Different levels of neutron irradiation are assumed; The neutron flux in the selected components is calculated by the MCNP5 code; The neutron spectra are input to the FISPACT code that computes the evolution of the radioactive species; For each irradiation scenario, the time behavior of the contact dose rate is determined. Abstract: The forthcoming deuterium–tritium (DT) campaign at the Joint European Torus (JET) will induce a significant activation of the system components. In the present work we evaluate the temporal evolution of the radioactive species in the main in-vessel components after the end of the future DT campaign, assuming different levels of neutron irradiation. The neutron flux in the selected components is calculated by the MCNP5 code using the emission source by a typical DT plasma. The resulting neutron spectra are then input to the FISPACT code that computes the evolution of the radioactive species generated by the neutron activation process. For each irradiation scenario, the time behavior of the contact dose rate is determined.

  9. Development of the prototype pneumatic transfer system for ITER neutron activation system.

    Science.gov (United States)

    Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  10. Neutron activation analysis via nuclear decay kinetics using gamma-ray spectroscopy at SFU

    Science.gov (United States)

    Domingo, Thomas; Chester, Aaron; Starosta, Krzysztof; Williams, Jonathan

    2016-09-01

    Gamma-ray spectroscopy is a powerful tool used in a variety of fields including nuclear and analytical chemistry, environmental science, and health risk management. At SFU, the Germanium detector for Elemental Analysis and Radiation Studies (GEARS), a low-background shielded high-purity germanium gamma-ray detector, has been used recently in all of the above fields. The current project aims to expand upon the number of applications for which GEARS can be used while enhancing its current functionality. A recent addition to the SFU Nuclear Science laboratory is the Thermo Scientific P 385 neutron generator. This device provides a nominal yield of 3 ×108 neutrons/s providing the capacity for neutron activation analysis, opening a major avenue of research at SFU which was previously unavailable. The isotopes created via neutron activation have a wide range of half-lives. To measure and study isotopes with half-lives above a second, a new analogue data acquisition system has been installed on GEARS allowing accurate measurements of decay kinetics. This new functionality enables identification and quantification of the products of neutron activation. Results from the neutron activation analysis of pure metals will be presented.

  11. A precise method to determine the activity of a weak neutron source using a germanium detector

    CERN Document Server

    Duke, M J M; Krauss, C B; Mekarski, P; Sibley, L

    2015-01-01

    A standard high purity germanium detector (HPGe) was used to determine the neutron activity of a weak americium-beryllium (AmBe) neutron source. Gamma rays were created through 27Al(n,n'), 27Al(n,gamma) and 1H(n,gamma) reactions induced by the neutrons on aluminum and acrylic disks. A Monte Carlo simulation was developed to model the efficiency of the detector system. The activity of our neutron source was determined to be 305.6 +/- 4.9 n/s. The result is consistent for the different gamma rays and was verified using additional simulations and measurements of the 4483 keV gamma ray produced directly from the AmBe source.

  12. Active palpation sensor for detecting prostatic cancer and hypertrophy

    Science.gov (United States)

    Tanaka, Mami; Furubayashi, Mitsuyuki; Tanahashi, Yoshikatsu; Chonan, Seiji

    2001-03-01

    This paper is concerned with the development of an active palpation sensor for detecting the prostatic cancer and hypertrophy. The receptor of the sensor is a polyvinylidene fluoride (PVDF) film placed on the surface of a sponge rubber layer. It is mounted on a linear z-translation bar and inserted into the examinee's rectum being protected by a medical rubber glove. After positioned faced to the prostate gland, the sensor probe is driven sinusoidally at about 50Hz with peak-to-peak amplitude 2mm. The voltage signal from the PVDF film is integrated over the sampling period and used as the output of sensor for extracting the features of the collected data. The evaluation of stiffness by the sensor on 27 normal and unhealthy prostate glands are compared with the results of diagnosis by the doctor's palpation. It is shown that the output of sensor becomes greater with an increase of the stiffness of the prostate gland, which has good correlation with the doctor's evaluation on the stiffness. Further results on the laboratory test reconfirm that the present sensor well discriminates the stiffness of the prostate glands in vivo and non-invasively.

  13. [Evaluation of calcium content in the human spine by in vivo neutron activation].

    Science.gov (United States)

    Zaĭchik, V E; Dubrovin, A P; Korelo, A M; Morukov, B V

    1993-01-01

    A technique of in vivo neutron activation analysis (NAA) of calcium levels in lumbar, thoracic and cervical segments of the spinal column separately and as a whole has been developed. Special device provides selective irradiation by neutrons of a vertebral segment under study while a highly-sensitive spectrometric unit registers radionuclides induced in bone tissue during radiation exposure. For radiation exposure 5 or 10 238Pu-Be neutron sources with 5.10(7) neutrons s-1 output of each source are used. The spectrometric unit consists of 4 scintillation detectors with NaI (Tl) crystals of 150 mm in diameter and 100 mm- thickness arranged in a line tightly one after another. The time of exposure depends on the number and mutual arrangement of the neutron sources and is selected given the dose equivalent at depth of positioning of the spinal cord does not exceed 1 cZv (REM), the quality factor for fast neutrons equals 10. The recording duration is 20 min, the intervals between radiation exposure and recording do not exceed 3 min. The magnitude of the total error of an individual measurement estimated by reproducibility of the data obtained in 2 series of in vivo NAA of the spinal calcium levels in 6 volunteers with the use of 5 neutron sources amounts to an average of 4.8%. When used 10 sources, this error can be reduced to 2.0-3.2%.

  14. Human Activity Recognition Using Heterogeneous Sensors

    NARCIS (Netherlands)

    Shoaib, M.

    Physical activities play an important role in our physical and mental well-being. The lack of such activities can negatively affect our well-being. Though people know the importance of physical activities, still they need regular motivational feedback to remain active in their daily life. In order

  15. Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring.

    Science.gov (United States)

    Fu, Xian Peng; Bu, Tian Zhao; Xi, Feng Ben; Cheng, Ting Hai; Zhang, Chi; Wang, Zhong Lin

    2017-09-20

    Pneumatic monitoring sensors have great demands for power supply in cylinder systems. Here, we present an embedded sliding triboelectric nanogenerator (TENG) in air cylinder as active sensors for position and velocity monitoring. The embedded TENG is composed of a circular poly(tetrafluoroethylene) polymer and a triangular copper electrode. The working mechanism as triboelectric active sensors and electric output performance are systematically investigated. By integrating into the pneumatic system, the embedded triboelectric active sensors have been used for real-time air pressure/flow monitoring and energy storage. Air pressures are measured from 0.04 to 0.12 MPa at a step of 0.02 MPa with a sensitivity of 49.235 V/MPa, as well as airflow from 50 to 250 L/min at a step of 50 L/min with a sensitivity of 0.002 μA·min/L. This work has first demonstrated triboelectric active sensors for pneumatic monitoring and may promote the development of TENG in intelligent pneumatic system.

  16. [Active crop canopy sensor-based nitrogen diagnosis for potato].

    Science.gov (United States)

    Yu, Jing; Li, Fei; Qin, Yong-Lin; Fan, Ming-Shou

    2013-11-01

    In the present study, two potato experiments involving different N rates in 2011 were conducted in Wuchuan County and Linxi County, Inner Mongolia. Normalized difference vegetation index (NDVI) was collected by an active GreenSeeker crop canopy sensor to estimate N status of potato. The results show that the NDVI readings were poorly correlated with N nutrient indicators of potato at vegetative Growth stage due to the influence of soil background. With the advance of growth stages, NDVI values were exponentially related to plant N uptake (R2 = 0.665) before tuber bulking stage and were linearly related to plant N concentration (R2 = 0.699) when plant fully covered soil. In conclusion, GreenSeeker active crop sensor is a promising tool to estimate N status for potato plants. The findings from this study may be useful for developing N recommendation method based on active crop canopy sensor.

  17. Development of ERK Activity Sensor, an in vitro, FRET-based sensor of Extracellular Regulated Kinase activity

    Directory of Open Access Journals (Sweden)

    Alberola-Ila José

    2005-07-01

    Full Text Available Abstract Background Study of ERK activation has thus far relied on biochemical assays that are limited to the use of phospho-specific antibodies and radioactivity in vitro, and analysis of whole cell populations in vivo. As with many systems, fluorescence resonance energy transfer (FRET can be utilized to make highly sensitive detectors of molecular activity. Here we introduce FRET-based ERK Activity Sensors, which utilize variants of Enhanced Green Fluorescent Protein fused by an ERK-specific peptide linker to detect ERK2 activity. Results ERK Activity Sensors display varying changes in FRET upon phosphorylation by active ERK2 in vitro depending on the composition of ERK-specific peptide linker sequences derived from known in vivo ERK targets, Ets1 and Elk1. Analysis of point mutations reveals specific residues involved in ERK binding and phosphorylation of ERK Activity Sensor 3. ERK2 also shows high in vitro specificity for these sensors over two other major MAP Kinases, p38 and pSAPK/JNK. Conclusion EAS's are a convenient, non-radioactive alternative to study ERK dynamics in vitro. They can be utilized to study ERK activity in real-time. This new technology can be applied to studying ERK kinetics in vitro, analysis of ERK activity in whole cell extracts, and high-throughput screening technologies.

  18. Active pixel sensors: the sensor of choice for future space applications

    NARCIS (Netherlands)

    Leijtens, J.; Theuwissen, A.; Rao, P.R.; Wang, X.; Xie, N.

    2007-01-01

    It is generally known that active pixel sensors (APS) have a number of advantages over CCD detectors if it comes to cost for mass production, power consumption and ease of integration. Nevertheless, most space applications still use CCD detectors because they tend to give better performance and have

  19. Ferroelectric thin-film active sensors for structural health monitoring

    Science.gov (United States)

    Lin, Bin; Giurgiutiu, Victor; Yuan, Zheng; Liu, Jian; Chen, Chonglin; Jiang, Jiechao; Bhalla, Amar S.; Guo, Ruyan

    2007-04-01

    Piezoelectric wafer active sensors (PWAS) have been proven a valuable tool in structural health monitoring. Piezoelectric wafer active sensors are able to send and receive guided Lamb/Rayleigh waves that scan the structure and detect the presence of incipient cracks and structural damage. In-situ thin-film active sensor deposition can eliminate the bonding layer to improve the durability issue and reduce the acoustic impedance mismatch. Ferroelectric thin films have been shown to have piezoelectric properties that are close to those of single-crystal ferroelectrics but the fabrication of ferroelectric thin films on structural materials (steel, aluminum, titanium, etc.) has not been yet attempted. In this work, in-situ fabrication method of piezoelectric thin-film active sensors arrays was developed using the nano technology approach. Specification for the piezoelectric thin-film active sensors arrays was based on electro-mechanical-acoustical model. Ferroelectric BaTiO3 (BTO) thin films were successfully deposited on Ni tapes by pulsed laser deposition under the optimal synthesis conditions. Microstructural studies by X-ray diffractometer and transmission electron microscopy reveal that the as-grown BTO thin films have the nanopillar structures with an average size of approximately 80 nm in diameter and the good interface structures with no inter-diffusion or reaction. The dielectric and ferroelectric property measurements exhibit that the BTO films have a relatively large dielectric constant, a small dielectric loss, and an extremely large piezoelectric response with a symmetric hysteresis loop. The research objective is to develop the fabrication and optimum design of thin-film active sensor arrays for structural health monitoring applications. The short wavelengths of the micro phased arrays will permit the phased-array imaging of smaller parts and smaller damage than is currently not possible with existing technology.

  20. 3D neutronic calculations: CAD-MCNP methodology applied to vessel activation in KOYO-F

    Science.gov (United States)

    Herreras, Y.; Lafuente, A.; Sordo, F.; Cabellos, O.; Perlado, J. M.

    2008-05-01

    This paper presents a methodology for 3D neutronic calculations suitable for complex and extensive geometries. The geometry of the system design is first fully modelled with a CAD program, and subsequently processed through a MCNP-CAD interface in order to generate an MCNP geometry file. Neutronic irradiation results are finally achieved running the MCNPX program, where the geometry input card used is directly the MCNP-CAD interface output. This methodology enables accurate neutronic calculations for complex geometries characterised by high detail levels. This procedure will be applied to the Fast Ignition Fusion Reactor KOYO-F to determine first neutron fluxes calculations along the blanket as well as the material activation in the reduced martensitic 9Cr-1Mo steel vessel.

  1. Benchmarking of activation reaction distribution in an intermediate energy neutron field.

    Science.gov (United States)

    Ogawa, Tatsuhiko; Morev, Mikhail N; Hirota, Masahiro; Abe, Takuya; Koike, Yuya; Iwai, Satoshi; Iimoto, Takeshi; Kosako, Toshiso

    2011-07-01

    Neutron-induced reaction rate depth profiles inside concrete shield irradiated by intermediate energy neutron were calculated using a Monte-Carlo code and compared with an experiment. An irradiation field of intermediate neutron produced in the forward direction from a thick (stopping length) target bombarded by 400 MeV nucleon(-1) carbon ions was arranged at the heavy ion medical accelerator in Chiba. Ordinary concrete shield of 90 cm thickness was installed 50 cm downstream the iron target. Activation detectors of aluminum, gold and gold covered with cadmium were inserted at various depths. Irradiated samples were extracted after exposure and gamma-ray spectrometry was performed for each sample. Comparison of experimental and calculated shows good agreement for both low- and high-energy neutron-induced reaction except for (27)Al(n,X)(24)Na reaction at the surface.

  2. 3D neutronic calculations: CAD-MCNP methodology applied to vessel activation in KOYO-F

    Energy Technology Data Exchange (ETDEWEB)

    Herreras, Y; Cabellos, O; Perlado, J M [Instituto de Fusion Nuclear (DENIM)/ETSII/Universidad Politecnica, Madrid (Spain); Lafuente, A; Sordo, F [Universidad Politecnica de Madrid (UPM), Madrid (Spain)], E-mail: yuri@denim.upm.es

    2008-05-15

    This paper presents a methodology for 3D neutronic calculations suitable for complex and extensive geometries. The geometry of the system design is first fully modelled with a CAD program, and subsequently processed through a MCNP-CAD interface in order to generate an MCNP geometry file. Neutronic irradiation results are finally achieved running the MCNPX program, where the geometry input card used is directly the MCNP-CAD interface output. This methodology enables accurate neutronic calculations for complex geometries characterised by high detail levels. This procedure will be applied to the Fast Ignition Fusion Reactor KOYO-F to determine first neutron fluxes calculations along the blanket as well as the material activation in the reduced martensitic 9Cr-1Mo steel vessel.

  3. Optical fiber sensor having an active core

    Science.gov (United States)

    Egalon, Claudio Oliveira (Inventor); Rogowski, Robert S. (Inventor)

    1993-01-01

    An optical fiber is provided. The fiber is comprised of an active fiber core which produces waves of light upon excitation. A factor ka is identified and increased until a desired improvement in power efficiency is obtained. The variable a is the radius of the active fiber core and k is defined as 2 pi/lambda wherein lambda is the wavelength of the light produced by the active fiber core. In one embodiment, the factor ka is increased until the power efficiency stabilizes. In addition to a bare fiber core embodiment, a two-stage fluorescent fiber is provided wherein an active cladding surrounds a portion of the active fiber core having an improved ka factor. The power efficiency of the embodiment is further improved by increasing a difference between the respective indices of refraction of the active cladding and the active fiber core.

  4. Determination of Lithium by Instrumental Neutron Activation Analysis

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Skanborg, Preben Zacho; Gwozdz, R.

    1977-01-01

    The fast transfer system in the DR 2 reactor for irradiation at a thermal neutron flux density of 1013 n·cm−2·sec−1 was used for the determination of lithium by the7Li(n, γ)8Li reaction. β-counting with a large perspex Cerenkov detector begun at 0.3 s after the end of irradiation, and multi...

  5. Neutron-Activated Gamma-Emission: Technology Review

    Science.gov (United States)

    2012-01-01

    defined in MCNPX to simulate the -spectra collected by NaI detectors (cell 6) from target (cell 3...numerical simulation. Safety issues are of great interest to users and are calculated in section 6. Ideas to increase target distance and reduce...neutron emission, target scatter, and gamma collection processes were simulated using MCNPX . MCNPX is a legacy code from Los Alamos National

  6. Neutron activation determination of gold in technogenic raw materials with different mineral composition

    Directory of Open Access Journals (Sweden)

    Yudakov Aleksandr A.

    2015-01-01

    Full Text Available The methods used to determine the gold content in the technogenic objects of gold mining were analyzed regarding their non-homogeneity and complexity of chemical and mineral compositions. A possible application of the neutron activation analysis with the use of the californium source of neutrons for determining the content of fine-grained and extra-fine-grained gold in the technogenic objects, including the bottom-ash waste of energy providers, is considered. It was demonstrated that the chemical composition of the sample affects the neuron flux distribution in the sample, which can essentially distort the results of the neutron activation analysis. In order to eliminate possible systematic errors investigations of the effect of the sample mineral composition on the results of the gold determination using the neutron activation analysis were carried out. Namely, a large mass of rock (3-5 kg was loaded into an activation zone using four matrix types such as silicate, carbon-containing, iron-containing, and titanium magnetite. It was shown that there wereno significant difference between the dispersal of the fluxes of thermal and resonance neutrons emitted from 252Cf during activation of the gold-containing technogenic samples with different mineral compositions.

  7. Remote monitoring of biodynamic activity using electric potential sensors

    Energy Technology Data Exchange (ETDEWEB)

    Harl, C J; Prance, R J; Prance, H [Centre for Physical Electronics and Quantum Technology, Department of Engineering and Design, School of Science and Technology, University of Sussex, Brighton, BN1 9QT (United Kingdom)], E-mail: c.j.harland@sussex.ac.uk

    2008-12-01

    Previous work in applying the electric potential sensor to the monitoring of body electrophysiological signals has shown that it is now possible to monitor these signals without needing to make any electrical contact with the body. Conventional electrophysiology makes use of electrodes which are placed in direct electrical contact with the skin. The electric potential sensor requires no cutaneous electrical contact, it operates by sensing the displacement current using a capacitive coupling. When high resolution body electrophysiology is required a strong (capacitive) coupling is used to maximise the collected signal. However, in remote applications where there is typically an air-gap between the body and the sensor only a weak coupling can be achieved. In this paper we demonstrate that the electric potential sensor can be successfully used for the remote sensing and monitoring of bioelectric activity. We show examples of heart-rate measurements taken from a seated subject using sensors mounted in the chair. We also show that it is possible to monitor body movements on the opposite side of a wall to the sensor. These sensing techniques have biomedical applications for non-contact monitoring of electrophysiological conditions and can be applied to passive through-the-wall surveillance systems for security applications.

  8. Neutron Activation Analysis of Soil Samples from Different Parts of Edirne in Turkey*

    Science.gov (United States)

    Zaim, N.; Dogan, C.; Camtakan, Z.

    2016-05-01

    The concentrations of constituent elements were determined in soil samples collected from different parts of the Maritza Basin, Edirne, Turkey. Neutron activation analysis, an extremely accurate technique, and the comparator method (using a standard) were applied for the first time in this region. After preparing the soil samples for neutron activation analysis, they were activated with thermal neutrons in a nuclear reactor, TRIGA-MARK II, at Istanbul Technical University. The activated samples were analyzed using a high-efficiency high-purity germanium detector, and gamma spectrometry was employed to determine the elemental concentration in the samples. Eight elements (chromium, manganese, cobalt, zinc, arsenic, molybdenum, cadmium, and barium) were qualitatively and quantitatively identified in 36 samples. The concentrations of some elements in the soil samples were high compared with values reported in the literature.

  9. Development of Enhanced, Permanently-Installed, Neutron Activation Diagnostic Hardware for NIF

    Science.gov (United States)

    Edwards, E. R.; Jedlovec, D. R.; Carrera, J. A.; Yeamans, C. B.

    2016-05-01

    Neutron activation diagnostics are baseline neutron yield and flux measurement instruments at the National Ignition Facility. Up to 19 activation samples are distributed around the target chamber. Currently the samples must be removed to be counted, creating a 1-2 week data turn-around time and considerable labor costs. An improved system consisting of a commercially available LaBr3(Ce) scintillator and Power over Ethernet electronics is under development. A machined zirconium-702 cap over the detector is the activation medium to measure the 90Zr(n,2n)89Zr reaction. The detectors are located at the current neutron activation diagnostic sites and monitored remotely. Because they collect data in real time yield values are returned within a few hours after a NIF shot.

  10. High Sensitive Neutron-Detection by Using a Self-Activation of Iodine-Containing Scintillators for the Photo-Neutron Monitoring around X-ray Radiotherapy Machines

    Science.gov (United States)

    Nohtomi, Akihiro; Wakabayashi, Genichiro; Kinoshita, Hiroyuki; Honda, Soichiro; Kurihara, Ryosuke; Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko; Ohga, Saiji; Nakamura, Katsumasa

    A novel method for evaluating the neutron dose-equivalent as well as neutron fluence around high-energy X-ray radiotherapy machines has been proposed and examined by using the self-activation of a CsI scintillator. Several filtering conditions were used to extract energy information of the neutron field. The shapes of neutron energy spectra were assumed to be practically unchanged at each three energy regions (thermal, epi-thermal and fast regions) for different irradiations around an X-ray linac whose acceleration potential was fixed to be a certain value. In order to know the actual neutron energy spectrum, an unfolding process was carried out for saturated activities of 128I generated inside the CsI scintillator under different filtering conditions; the response function matrix for each filtering condition was calculated by a Monte Carlo simulation. As the result, neutron dose-equivalent was estimated to be 0.14 (mSv/Gy) at 30 cm from the isocenter of linac. It has been revealed that fast neutron component dominated the total dose-equivalent.

  11. Active Low Intrusion Hybrid Monitor for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Marlon Navia

    2015-09-01

    Full Text Available Several systems have been proposed to monitor wireless sensor networks (WSN. These systems may be active (causing a high degree of intrusion or passive (low observability inside the nodes. This paper presents the implementation of an active hybrid (hardware and software monitor with low intrusion. It is based on the addition to the sensor node of a monitor node (hardware part which, through a standard interface, is able to receive the monitoring information sent by a piece of software executed in the sensor node. The intrusion on time, code, and energy caused in the sensor nodes by the monitor is evaluated as a function of data size and the interface used. Then different interfaces, commonly available in sensor nodes, are evaluated: serial transmission (USART, serial peripheral interface (SPI, and parallel. The proposed hybrid monitor provides highly detailed information, barely disturbed by the measurement tool (interference, about the behavior of the WSN that may be used to evaluate many properties such as performance, dependability, security, etc. Monitor nodes are self-powered and may be removed after the monitoring campaign to be reused in other campaigns and/or WSNs. No other hardware-independent monitoring platforms with such low interference have been found in the literature.

  12. Active Low Intrusion Hybrid Monitor for Wireless Sensor Networks.

    Science.gov (United States)

    Navia, Marlon; Campelo, Jose C; Bonastre, Alberto; Ors, Rafael; Capella, Juan V; Serrano, Juan J

    2015-09-18

    Several systems have been proposed to monitor wireless sensor networks (WSN). These systems may be active (causing a high degree of intrusion) or passive (low observability inside the nodes). This paper presents the implementation of an active hybrid (hardware and software) monitor with low intrusion. It is based on the addition to the sensor node of a monitor node (hardware part) which, through a standard interface, is able to receive the monitoring information sent by a piece of software executed in the sensor node. The intrusion on time, code, and energy caused in the sensor nodes by the monitor is evaluated as a function of data size and the interface used. Then different interfaces, commonly available in sensor nodes, are evaluated: serial transmission (USART), serial peripheral interface (SPI), and parallel. The proposed hybrid monitor provides highly detailed information, barely disturbed by the measurement tool (interference), about the behavior of the WSN that may be used to evaluate many properties such as performance, dependability, security, etc. Monitor nodes are self-powered and may be removed after the monitoring campaign to be reused in other campaigns and/or WSNs. No other hardware-independent monitoring platforms with such low interference have been found in the literature.

  13. Analytical capabilities of the new thermal neutron prompt gamma-ray activation analysis instrument at the National Institute of Standards and Technology Center for Neutron Research

    Energy Technology Data Exchange (ETDEWEB)

    Mackey, E.A. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Anderson, D.L. [US Food and Drug Administration, Elemental Research Branch, College Park, MD (United States)

    2004-07-01

    A new thermal neutron prompt gamma-ray activation analysis (PGAA) instrument was designed and built to replace the original PGAA system at the National Institute of Standards and Technology's Center for Neutron Research. The new PGAA instrument was constructed to achieve a reduction of the fast neutron beam component, a reduction of background gamma-radiation (including gamma-ray lines that directly interfere with element analyses, low-energy scattered gamma rays, and Compton scattered gamma rays), improvement in element sensitivities and limits of detection (LODs), and a simplified instrument set-up procedure. (orig.)

  14. Analysis of Neutron Induced Gamma Activity in Lowbackground Ge - Spectroscopy Systems

    Science.gov (United States)

    Jovančević, Nikola; Krmar, Midrag

    Neutron interactions with materials of Ge-spectroscopy systems are one of the main sources of background radiation in low-level gamma spectroscopy measurements. Because of that detailed analysis of neutron induced gamma activity in low-background Ge-spectroscopy systems was done. Two HPGe detectors which were located in two different passive shields: one in pre-WW II made iron and the second in commercial low background lead were used in the experiment. Gamma lines emitted after neutron capture, as well as after inelastic scattering on the germanium crystal and shield materials (lead, iron, hydrogen, NaI) were detected and then analyzed. The thermal and fast neutron fluxes were calculated and their values were compared for the two different kinds of detector shield. The relative intensities of several gamma lines emitted after the inelastic scattering of neutrons (created by cosmic muons) in 56Fe were report. These relative intensities of detected gamma lines of 56Fe are compared with the results collected in the same iron shield by the use of the 252Cf neutrons.

  15. Fusion of Smartphone Motion Sensors for Physical Activity Recognition

    NARCIS (Netherlands)

    Shoaib, Muhammad; Bosch, Stephan; Durmaz Incel, Ozlem; Scholten, Hans; Havinga, Paul J.M.

    2014-01-01

    For physical activity recognition, smartphone sensors, such as an accelerometer and a gyroscope, are being utilized in many research studies. So far, particularly, the accelerometer has been extensively studied. In a few recent studies, a combination of a gyroscope, a magnetometer (in a supporting r

  16. Fusion of smartphone motion sensors for physical activity recognition.

    Science.gov (United States)

    Shoaib, Muhammad; Bosch, Stephan; Incel, Ozlem Durmaz; Scholten, Hans; Havinga, Paul J M

    2014-06-10

    For physical activity recognition, smartphone sensors, such as an accelerometer and a gyroscope, are being utilized in many research studies. So far, particularly, the accelerometer has been extensively studied. In a few recent studies, a combination of a gyroscope, a magnetometer (in a supporting role) and an accelerometer (in a lead role) has been used with the aim to improve the recognition performance. How and when are various motion sensors, which are available on a smartphone, best used for better recognition performance, either individually or in combination? This is yet to be explored. In order to investigate this question, in this paper, we explore how these various motion sensors behave in different situations in the activity recognition process. For this purpose, we designed a data collection experiment where ten participants performed seven different activities carrying smart phones at different positions. Based on the analysis of this data set, we show that these sensors, except the magnetometer, are each capable of taking the lead roles individually, depending on the type of activity being recognized, the body position, the used data features and the classification method employed (personalized or generalized). We also show that their combination only improves the overall recognition performance when their individual performances are not very high, so that there is room for performance improvement. We have made our data set and our data collection application publicly available, thereby making our experiments reproducible.

  17. Fusion of Smartphone Motion Sensors for Physical Activity Recognition

    Directory of Open Access Journals (Sweden)

    Muhammad Shoaib

    2014-06-01

    Full Text Available For physical activity recognition, smartphone sensors, such as an accelerometer and a gyroscope, are being utilized in many research studies. So far, particularly, the accelerometer has been extensively studied. In a few recent studies, a combination of a gyroscope, a magnetometer (in a supporting role and an accelerometer (in a lead role has been used with the aim to improve the recognition performance. How and when are various motion sensors, which are available on a smartphone, best used for better recognition performance, either individually or in combination? This is yet to be explored. In order to investigate this question, in this paper, we explore how these various motion sensors behave in different situations in the activity recognition process. For this purpose, we designed a data collection experiment where ten participants performed seven different activities carrying smart phones at different positions. Based on the analysis of this data set, we show that these sensors, except the magnetometer, are each capable of taking the lead roles individually, depending on the type of activity being recognized, the body position, the used data features and the classification method employed (personalized or generalized. We also show that their combination only improves the overall recognition performance when their individual performances are not very high, so that there is room for performance improvement. We have made our data set and our data collection application publicly available, thereby making our experiments reproducible.

  18. Sensor fusion for active vibration isolation in precision equipment

    NARCIS (Netherlands)

    Tjepkema, D.; Dijk, van J.; Soemers, H.M.J.R.

    2012-01-01

    Sensor fusion is a promising control strategy to improve the performance of active vibration isolation systems that are used in precision equipment. Normally, those vibration isolation systems are only capable of realizing a low transmissibility. Additional objectives are to increase the damping rat

  19. Low Temperature Irradiation Applied to Neutron Activation Analysis of Mercury In Human Whole Blood

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D.

    1966-02-15

    The distribution of mercury in human whole blood has been studied by means of neutron activation analysis. During the irradiation procedure the samples were kept at low temperature by freezing them in a cooling device in order to prevent interferences caused by volatilization and contamination. The mercury activity was separated by means of distillation and ion exchange techniques.

  20. Simultaneous Determination of Arsenic, Manganese, and Selenium in Biological Materials by Neutron-Activation Analysis

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Damsgaard, Else

    1973-01-01

    A new method was developed for the simultaneous determination of arsenic, manganese, and selenium in biological material by thermal-neutron activation analysis. The use of 81 mSe as indicator for selenium permitted a reduction of activation time to 1 hr for a 1 g sample, and the possibility of loss...

  1. The cross-section data from neutron activation experiments on niobium in the NPI p-7Li quasi-monoenergetic neutron field

    Directory of Open Access Journals (Sweden)

    Simakov S.P.

    2010-10-01

    Full Text Available The reaction of protons on 7Li target produces the high-energy quasi- monoenergetic neutron spectrum with the tail to lower energies. Proton energies of 19.8, 25.1, 27.6, 30.1, 32.6, 35.0 and 37.4 MeV were used to obtain quasi-monoenergetic neutrons with energies of 18, 21.6, 24.8, 27.6, 30.3, 32.9 and 35.6 MeV, respectively. Nb cross-section data for neutron energies higher than 22.5 MeV do not exist in the literature. Nb is the important material for fusion applications (IFMIF as well. The variable-energy proton beam of NPI cyclotron is utilized for the production of neutron field using thin lithium target. The carbon backing serves as the beam stopper. The system permits to produce neutron flux density about 109  n/cm2/s in peak at 30 MeV neutron energy. The niobium foils of 15 mm in diameter and approx. 0.75 g weight were activated. The nuclear spectroscopy methods with HPGe detector technique were used to obtain the activities of produced isotopes. The large set of neutron energies used in the experiment allows us to make the complex study of the cross-section values. The reactions (n,2n, (n,3n, (n,4n, (n,He3, (n,α and (n,2nα are studied. The cross-sections data of the (n,4n and (n,2nα are obtained for the first time. The cross-sections of (n,2n and (n,α reactions for higher neutron energies are strongly influenced by low energy tail of neutron spectra. This effect is discussed. The results are compared with the EAF-2007 library.

  2. Fluorescent peptide sensors for tyrosylprotein sulfotransferase activity.

    Science.gov (United States)

    Zhou, Wenbo; Duckworth, Benjamin P; Geraghty, Robert J

    2014-09-15

    Tyrosine sulfurylation is a post-translational modification important for protein-protein interactions in the extracellular space that are instrumental in cell adhesion, cell signaling, immune responses, and pathogen recognition of host cells. Tyrosine sulfurylation is catalyzed by the tyrosylprotein sulfotransferases (TPSTs), and in humans there are two isoforms: hTPST1 and hTPST2. The study of hTPST function and the development of small molecule probes to examine the role of hTPSTs in cell biology have been delayed by the absence of a continuous direct assay for hTPST activity. We have developed a fluorescent peptide-based assay to directly monitor tyrosine sulfurylation in real time. TPST-mediated tyrosine sulfurylation of the peptides disrupts fluorophore quenching and results in increased fluorescence emission. The assay can be used to study TPST enzymatic activity, and we show that recombinant hTPSTs are active in the absence of divalent metal ions and that optimal activity is at pH 6.0. We further show that the assay can also be used to identify inhibitors of tyrosine sulfurylation. A clear understanding of hTPST function in normal cell biology and in disease states will require the identification of small molecule inhibitors or probes to modulate enzymatic activity, and our results will facilitate that process.

  3. Validation of MCNP NPP Activation Simulations for Decommissioning Studies by Analysis of NPP Neutron Activation Foil Measurement Campaigns

    Directory of Open Access Journals (Sweden)

    Volmert Ben

    2016-01-01

    Full Text Available In this paper, an overview of the Swiss Nuclear Power Plant (NPP activation methodology is presented and the work towards its validation by in-situ NPP foil irradiation campaigns is outlined. Nuclear Research and consultancy Group (NRG in The Netherlands has been given the task of performing the corresponding neutron metrology. For this purpose, small Aluminium boxes containing a set of circular-shaped neutron activation foils have been prepared. After being irradiated for one complete reactor cycle, the sets have been successfully retrieved, followed by gamma-spectrometric measurements of the individual foils at NRG. Along with the individual activities of the foils, the reaction rates and thermal, intermediate and fast neutron fluence rates at the foil locations have been determined. These determinations include appropriate corrections for gamma self-absorption and neutron self-shielding as well as corresponding measurement uncertainties. The comparison of the NPP Monte Carlo calculations with the results of the foil measurements is done by using an individual generic MCNP model functioning as an interface and allowing the simulation of individual foil activation by predetermined neutron spectra. To summarize, the comparison between calculation and measurement serve as a sound validation of the Swiss NPP activation methodology by demonstrating a satisfying agreement between measurement and calculation. Finally, the validation offers a chance for further improvements of the existing NPP models by ensuing calibration and/or modelling optimizations for key components and structures.

  4. Towards physical activity recognition using smartphone sensors

    NARCIS (Netherlands)

    Shoaib, Muhammad; Scholten, Hans; Havinga, P.J.M.

    2013-01-01

    In recent years, the use of a smartphone accelerometer in physical activity recognition has been well studied. However, the role of a gyroscope and a magnetometer is yet to be explored, both when used alone as well as in combination with an accelerometer. For this purpose, we investigate the role of

  5. Large sample neutron activation analysis: a challenge in cultural heritage studies.

    Science.gov (United States)

    Stamatelatos, Ion E; Tzika, Faidra

    2007-07-01

    Large sample neutron activation analysis compliments and significantly extends the analytical tools available for cultural heritage and authentication studies providing unique applications of non-destructive, multi-element analysis of materials that are too precious to damage for sampling purposes, representative sampling of heterogeneous materials or even analysis of whole objects. In this work, correction factors for neutron self-shielding, gamma-ray attenuation and volume distribution of the activity in large volume samples composed of iron and ceramic material were derived. Moreover, the effect of inhomogeneity on the accuracy of the technique was examined.

  6. Corrections in the gold foil activation method for determination of neutron beam density

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage

    1967-01-01

    example for a reactor beam transmitted through a 30 cm Bi filter. The effective cross section differs 0.5% from the capture cross section at 2200 m/s. For a 20 mg/cm2 Au foil the correction for beam attenuation and hardening through the foil is 0.7% and the activity correction is 1.5%.......A finite foil thickness and deviation in the cross section from the 1ν law imply corrections in the determination of neutron beam densities by means of foil activation. These corrections, which depend on the neutron velocity distribution, have been examined in general and are given in a specific...

  7. Measurement of neutron induced activation of the SCT end-cap module

    CERN Document Server

    Linhart, V; Kolros, A; Lebel, C; Leroy, C; Pospísil, S; Stekl, I; Vobecky, M

    2005-01-01

    Results of the experimental study of the induced radioactivity generated by neutron irradiation in the semiconductor tracker end-cap module are presented. The purpose of the experiment was to identify the radioisotopes produced in the module by neutron interactions. The irradiation was done in the active zone of the VR-1 CTU Prague reactor. The identification and quantification of radioisotopes were based on detailed analysis of gamma-ray spectra, which were measured with a HPGe-detector. The nuclear processes of all 26 observed radioisotopes and their activities at the end of the irradiation were determined.

  8. Availability of essential trace elements in Ayurvedic Indian medicinal herbs using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Singh, V.; Garg, A.N. [Nagpur Univ. (India). Dept. of Chemistry

    1997-01-01

    Specific parts of several plants (fruits, leaves, stem, bark and roots) often used as medicines in the Indian Ayurvedic system have been analysed for 20 elements (As, Ba, Br, Ca, Cl, Co, Cr, Cu, Fe, K, Mn, Mo, Na, P, Rb, Sb, Sc, Se, Sr and Zn) by employing instrumental neutron activation analysis (INAA). The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted using high resolution gamma ray spectrometry. Most of the medicinal herbs have been found to be rich in one or more of the elements under study. (Author).

  9. Ground tests with active neutron instrumentation for the planetary science missions

    Energy Technology Data Exchange (ETDEWEB)

    Litvak, M.L., E-mail: litvak@mx.iki.rssi.ru [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Mitrofanov, I.G.; Sanin, A.B. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Jun, I. [Jet Propulsion Laboratory, Pasadena, CA USA (United States); Kozyrev, A.S. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Krylov, A.; Shvetsov, V.N.; Timoshenko, G.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Starr, R. [Catholic University of America, Washington DC (United States); Zontikov, A. [Joint Institute for Nuclear Research, Dubna (Russian Federation)

    2015-07-11

    We present results of experimental work performed with a spare flight model of the DAN/MSL instrument in a newly built ground test facility at the Joint Institute for Nuclear Research. This instrument was selected for the tests as a flight prototype of an active neutron spectrometer applicable for future landed missions to various solid solar system bodies. In our experiment we have fabricated simplified samples of planetary material and tested the capability of neutron activation methods to detect thin layers of water/water ice lying on top of planetary dry regolith or buried within a dry regolith at different depths.

  10. First principle active neutron coincidence counting measurements of uranium oxide

    Science.gov (United States)

    Goddard, Braden; Charlton, William; Peerani, Paolo

    2014-03-01

    Uranium is present in most nuclear fuel cycle facilities ranging from uranium mines, enrichment plants, fuel fabrication facilities, nuclear reactors, and reprocessing plants. The isotopic, chemical, and geometric composition of uranium can vary significantly between these facilities, depending on the application and type of facility. Examples of this variation are: enrichments varying from depleted (~0.2 wt% 235U) to high enriched (>20 wt% 235U); compositions consisting of U3O8, UO2, UF6, metallic, and ceramic forms; geometries ranging from plates, cans, and rods; and masses which can range from a 500 kg fuel assembly down to a few grams fuel pellet. Since 235U is a fissile material, it is routinely safeguarded in these facilities. Current techniques for quantifying the 235U mass in a sample include neutron coincidence counting. One of the main disadvantages of this technique is that it requires a known standard of representative geometry and composition for calibration, which opens up a pathway for potential erroneous declarations by the State and reduces the effectiveness of safeguards. In order to address this weakness, the authors have developed a neutron coincidence counting technique which uses the first principle point-model developed by Boehnel instead of the "known standard" method. This technique was primarily tested through simulations of 1000 g U3O8 samples using the Monte Carlo N-Particle eXtended (MCNPX) code. The results of these simulations showed good agreement between the simulated and exact 235U sample masses.

  11. A CMOS active pixel sensor for retinal stimulation

    Science.gov (United States)

    Prydderch, Mark L.; French, Marcus J.; Mathieson, Keith; Adams, Christopher; Gunning, Deborah; Laudanski, Jonathan; Morrison, James D.; Moodie, Alan R.; Sinclair, James

    2006-02-01

    Degenerative photoreceptor diseases, such as age-related macular degeneration and retinitis pigmentosa, are the most common causes of blindness in the western world. A potential cure is to use a microelectronic retinal prosthesis to provide electrical stimulation to the remaining healthy retinal cells. We describe a prototype CMOS Active Pixel Sensor capable of detecting a visual scene and translating it into a train of electrical pulses for stimulation of the retina. The sensor consists of a 10 x 10 array of 100 micron square pixels fabricated on a 0.35 micron CMOS process. Light incident upon each pixel is converted into output current pulse trains with a frequency related to the light intensity. These outputs are connected to a biocompatible microelectrode array for contact to the retinal cells. The flexible design allows experimentation with signal amplitudes and frequencies in order to determine the most appropriate stimulus for the retina. Neural processing in the retina can be studied by using the sensor in conjunction with a Field Programmable Gate Array (FPGA) programmed to behave as a neural network. The sensor has been integrated into a test system designed for studying retinal response. We present the most recent results obtained from this sensor.

  12. Bayesian calibration of reactor neutron flux spectrum using activation detectors measurements: Application to CALIBAN reactor

    Energy Technology Data Exchange (ETDEWEB)

    Cartier, J. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, DIF, F-91297 Arpajon (France); Casoli, P. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, Valduc, F-21120 Is sur Tille (France); Chappert, F. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, DIF, F-91297 Arpajon (France)

    2013-07-01

    In this paper, we present calibration methods in order to estimate reactor neutron flux spectrum and its uncertainties by using integral activation measurements. These techniques are performed using Bayesian and MCMC framework. These methods are applied to integral activation experiments in the cavity of the CALIBAN reactor. We estimate the neutron flux and its related uncertainties. The originality of this work is that these uncertainties take into account measurements uncertainties, cross-sections uncertainties and model error. In particular, our results give a very good approximation of the total flux and indicate that neutron flux from MCNP simulation for energies above about 5 MeV seems to overestimate the 'real flux'. (authors)

  13. Measuring neutron yield and ρR anisotropies with activation foils at the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Bleuel D.L.

    2013-11-01

    Full Text Available Neutron yields at the National Ignition Facility (NIF are measured with a suite of diagnostics, including activation of ∼20–200 g samples of materials undergoing a variety of energy-dependent neutron reactions. Indium samples were mounted on the end of a Diagnostic Instrument Manipulator (DIM, 25–50 cm from the implosion, to measure 2.45 MeV D-D fusion neutron yield. The 336.2 keV gamma rays from the 4.5 hour isomer of 115mIn produced by (n,n′ reactions are counted in high-purity germanium detectors. For capsules producing D-T fusion reactions, zirconium and copper are activated via (n,2n reactions at various locations around the target chamber and bay, measuring the 14 MeV neutron yield to accuracies on order of 7%. By mounting zirconium samples on ports at nine locations around the NIF chamber, anisotropies in the primary neutron emission due to fuel areal density asymmetries can be measured to a relative precision of 3%.

  14. Analysis of the neutron component at high altitude mountains using active and passive measurement devices

    Energy Technology Data Exchange (ETDEWEB)

    Hajek, M. E-mail: mhajek@ati.ac.at; Berger, T.; Schoener, W.; Vana, N

    2002-01-01

    The European Council directive 96/29/Euratom requires dosimetric precautions if the effective dose exceeds 1 mSv/a. On an average, this value is exceeded by aircrew members. Roughly half of the radiation exposure at flight altitudes is caused by cosmic ray-induced neutrons. Active ({sup 6}LiI(Eu)-scintillator) and passive (TLDs) Bonner sphere spectrometers were used to determine the neutron energy spectra atop Mt. Sonnblick (3105 m) and Mt. Kitzsteinhorn (3029 m). Further measurements in a mixed radiation field at CERN as well as in a proton beam of 62 MeV at Paul Scherrer Institute, Switzerland, confirmed that not only neutrons but also charged particles contribute to the readings of active detectors, whereas TLD-600 and TLD-700 in pair allow the determination of the thermal neutron flux. Unfolding of the detector data obtained atop both mountains shows two relative maxima around 1 MeV and 85 MeV, which have to be considered for the assessment of the biologically relevant dose equivalent. By convoluting the spectra with appropriate conversion functions the neutron dose equivalent rate was determined to be 150{+-}15 nSv/h. The total dose equivalent rate determined by the HTR-method was 210{+-}15 nSv/h. The results are in good agreement with LET-spectrometer and Sievert counter measurements carried out simultaneously.

  15. A bismuth activation counter for high sensitivity pulsed 14 MeV neutrons

    Science.gov (United States)

    Burns, E. J. T.; Thacher, P. D.; Hassig, G. J.; Decker, R. D.; Romero, J. A.; Barrett, K. P.

    2011-08-01

    We have built a fast neutron bismuth activation counter that measures activation counts from pulsed 14-MeV neutron generators for incident neutron fluences between 30 and 300 neutrons/cm2 at 15.2 cm (6 in.). The activation counter consists of a large bismuth germanate (BGO) detector surrounded by a bismuth metal shield in front of and concentric with the cylindrical detector housing. The 14 MeV neutrons activate the 2.6-millisecond (ms) isomer in the shield and the detector by the reaction 209Bi (n,2nγ) 208mBi. The use of millisecond isomers and activation counting times minimizes the background from other activated materials and the environment. In addition to activation, the bismuth metal shields against other outside radiation sources. We have tested the bismuth activation counter, simultaneously, with two data acquisition systems (DASs) and both give similar results. The two-dimensional (2D) DAS and three dimensional (3D) DAS both consist of pulse height analysis (PHA) systems that can be used to discriminate against gamma radiations below 300 keV photon energy, so that the detector can be used strictly as a counter. If the counting time is restricted to less than 25 ms after the neutron pulse, there are less than 10 counts of background for single pulse operation in all our operational environments tested so far. High-fluence neutron generator operations are restricted by large dead times and pulse height saturation. When we operate our 3D DAS PHA system in list mode acquisition (LIST), real-time corrections to dead time or live time can be made on the scale of 1 ms time windows or dwell times. The live time correction is consistent with nonparalyzable models for dead time of 1.0±0.2 μs for our 3D DAS and 1.5±0.3 μs for our 2D DAS dominated by our fixed time width analog to digital converters (ADCs). With the same solid angle, we have shown that the bismuth activation counter has a factor of 4 increase in sensitivity over our lead activation counter

  16. Luminescent and Scintillating Properties of Lanthanum Fluoride Nanocrystals in Response to Gamma/Neutron Irradiation: Codoping with Ce Activator, Yb Wavelength Shifter, and Gd Neutron Captor

    CERN Document Server

    Vargas, José M; Sidelnik, Iván; Brito, David Rondón; Palomino, Luis A Rodríguez; Mayer, Roberto E

    2016-01-01

    A novel concept for detection and spectroscopy of gamma rays, and detection of thermal neutrons based on codoped lanthanum fluoride nanocrystals containing gadolinium is presented.The trends of colloidal synthesis of the mentioned material, LaF3 co-doped with Ce as the activator, Yb as the wavelength-shifter and Gd as the neutron captor, is reported. Nanocrystals of the mentioned material were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS), optical absorption, and photoluminescence spectroscopy. Gamma detection and its potential spectroscopy feature have been confirmed. The neutron detection capability has been confirmed by experiments performed using a 252Cf neutron source.

  17. Energy distribution of the neutron flux measurements at the Chilean Reactor RECH-1 using multi-foil neutron activation and the Expectation Maximization unfolding algorithm.

    Science.gov (United States)

    Molina, F; Aguilera, P; Romero-Barrientos, J; Arellano, H F; Agramunt, J; Medel, J; Morales, J R; Zambra, M

    2017-08-04

    We present a methodology to obtain the energy distribution of the neutron flux of an experimental nuclear reactor, using multi-foil activation measurements and the Expectation Maximization unfolding algorithm, which is presented as an alternative to well known unfolding methods such as GRAVEL. Self-shielding flux corrections for energy bin groups were obtained using MCNP6 Monte Carlo simulations. We have made studies at the at the Dry Tube of RECH-1 obtaining fluxes of 1.5(4)×10(13)cm(-2)s(-1) for the thermal neutron energy region, 1.9(5)×10(12)cm(-2)s(-1) for the epithermal neutron energy region, and 4.3(11)×10(11)cm(-2)s(-1) for the fast neutron energy region. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Wireless sensor networks for active vibration control in automobile structures

    Science.gov (United States)

    Mieyeville, Fabien; Ichchou, Mohamed; Scorletti, Gérard; Navarro, David; Du, Wan

    2012-07-01

    Wireless sensor networks (WSNs) are nowadays widely used in monitoring and tracking applications. This paper presents the feasibility of using WSNs in active vibration control strategies. The method employed here involves active-structural acoustic control using piezoelectric sensors distributed on a car structure. This system aims at being merged with a WSN whose head node collects data and processes control laws so as to command piezoelectric actuators wisely placed on the structure. We will study the feasibility of implementing WSNs in active vibration control and introduce a complete design methodology to optimize hardware/software and control law synergy in mechatronic systems. A design space exploration will be conducted so as to identify the best WSN platform and the resulting impact on control.

  19. Applied research and development of neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Bak, Sung Ryel; Park, Yong Chul; Kim, Young Ki; Chung, Hwan Sung; Park, Kwang Won; Kang, Sang Hun

    2000-05-01

    This report is written for results of research and development as follows : improvement of neutron irradiation facilities, counting system and development of automation system and capsules for NAA in HANARO ; improvement of analytical procedures and establishment of analytical quality control and assurance system; applied research and development of environment, industry and human health and its standardization. For identification and standardization of analytical method, environmental biological samples and polymer are analyzed and uncertainity of measurement are estimated. Also data intercomparison and proficency test were performed. Using airborne particulate matter chosen as a environmental indicators, trace elemental concentrations of sample collected at urban and rural site are determined and then the calculation of statistics and the factor analysis are carried out for investigation of emission source. International cooperation research project was carried out for utilization of nuclear techniques.

  20. Active resonant subwavelength grating for scannerless range imaging sensors.

    Energy Technology Data Exchange (ETDEWEB)

    Kemme, Shanalyn A.; Nellums, Robert O.; Boye, Robert R.; Peters, David William

    2006-11-01

    In this late-start LDRD, we will present a design for a wavelength-agile, high-speed modulator that enables a long-term vision for the THz Scannerless Range Imaging (SRI) sensor. It takes the place of the currently-utilized SRI micro-channel plate which is limited to photocathode sensitive wavelengths (primarily in the visible and near-IR regimes). Two of Sandia's successful technologies--subwavelength diffractive optics and THz sources and detectors--are poised to extend the capabilities of the SRI sensor. The goal is to drastically broaden the SRI's sensing waveband--all the way to the THz regime--so the sensor can see through image-obscuring, scattering environments like smoke and dust. Surface properties, such as reflectivity, emissivity, and scattering roughness, vary greatly with the illuminating wavelength. Thus, objects that are difficult to image at the SRI sensor's present near-IR wavelengths may be imaged more easily at the considerably longer THz wavelengths (0.1 to 1mm). The proposed component is an active Resonant Subwavelength Grating (RSG). Sandia invested considerable effort on a passive RSG two years ago, which resulted in a highly-efficient (reflectivity greater than gold), wavelength-specific reflector. For this late-start LDRD proposal, we will transform the passive RSG design into an active laser-line reflector.

  1. Exploration of Adiabatic Resonance Crossing Through Neutron Activator Design for Thermal and Epithermal Neutron Formation in (99)Mo Production and BNCT Applications.

    Science.gov (United States)

    Khorshidi, Abdollah

    2015-10-01

    A feasibility study was performed to design thermal and epithermal neutron sources for radioisotope production and boron neutron capture therapy (BNCT) by moderating fast neutrons. The neutrons were emitted from the reaction between (9)Be, (181)Ta, and (184)W targets and 30 MeV protons accelerated by a small cyclotron at 300 μA. In this study, the adiabatic resonance crossing (ARC) method was investigated by means of (207)Pb and (208)Pb moderators, graphite reflector, and boron absorber around the moderator region. Thermal/epithermal flux, energy, and cross section of accumulated neutrons in the activator were examined through diverse thicknesses of the specified regions. Simulation results revealed that the (181)Ta target had the highest neutron yield, and also tungsten was found to have the highest values in both surface and volumetric flux ratio. Transmutation in the (98)Mo sample through radiative capture was investigated for the natural lead moderator. When the sample radial distance from the target was increased inside the graphite region, the production yield had the greatest value of activity. The potential of the ARC method is a replacement or complements the current reactor-based supply sources of BNCT purposes.

  2. Neutron activation analysis of phytotherapic obtained from medicinal plants; Analise por ativacao com neutrons de fitoterapicos obtidos de plantas medicinais

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Henrique S. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: hs_moreira@hotmail.com; Saiki, Mitiko; Vasconcellos, Marina B.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: mitiko@ipen.br; mbvascon@ipen.br

    2007-07-01

    This paper determines the inorganic constituents in phytotherapic samples for posterior study of the relationship existent among the concentrations of the found elements and the their possible therapeutical effects. The samples of phytotherapic pills (Centella asiatica, Ginkgo biloba and Ginseng) were analysed by using neutron activation analysis (NAA). The As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sc, Se and Zn samples were determined in the phytotherapics, The Centella asiatica presented the higher concentrations of Br, Co, Cr, Fe, K, La, Na, Rb, Sc, Se and Zn. In the sample of Ginko biloba, higher levels of As and Ca were found, while in the sample ol Ginseng the element As were not detected. The found results have shown the the NAA method is appropriated for analysing this type of materials due to his simplicity, multielemental capacity and quality of the results obtained. (author)

  3. Target preparation and neutron activation analysis a successful story at IRMM

    CERN Document Server

    Robouch, P; Eguskiza, M; Maguregui, M I; Pommé, S; Ingelbrecht, C

    2002-01-01

    The main task of a target producer is to make well characterized and homogeneous deposits on specific supports. Alpha and/or gamma spectrometry are traditionally used to monitor the quality of actinide deposits. With the increasing demand for enriched stable isotope targets, other analytical techniques, such as ICP-MS and NAA, are needed. This paper presents the application of neutron activation analysis to quality control of 'thin' targets, 'thicker' neutron dosimeters and 'thick' bronze disks prepared by the Reference Materials Unit at the Institute of Reference Materials and Measurements.

  4. Thermally-Activated Post-Glitch Response of the Neutron Star Inner Crust and Core

    CERN Document Server

    Link, Bennett

    2013-01-01

    Pinning of superfluid vortices is predicted to prevail throughout much of a neutron star. Here I develop a description of the coupling through thermally-activated vortex slippage}, and calculate the post-glitch response of a neutron star to a spin glitch. The theory has three robust conclusions: 1) If vortex pinning occurs in the core, typical large glitches decouple the core superfluid from the charged components over observable timescales. Core response to a glitch has a distinct observational signature that could be identified through analyses of existing and future timing data. 2) Post-glitch response over short timescales (days) in pulsars with large glitches (fractional spin jumps of $\\Delta\

  5. Neutron activation of natural zinc samples at kT = 25 keV

    OpenAIRE

    Reifarth, R.; Dababneh, S.; Heil, M.; Käppeler, F.; Plag, R.; Sonnabend, K.; Uberseder, E.

    2013-01-01

    The neutron-capture cross sections of 64Zn, 68Zn, and 70Zn have been measured with the activation technique in a quasistellar neutron spectrum corresponding to a thermal energy of kT = 25 keV. By a series of repeated irradiations with different experimental conditions, an uncertainty of 3% could be achieved for the 64Zn(n,g)65Zn cross section and for the partial cross section 68Zn(n,g)69Zn-m feeding the isomeric state in 69Zn. For the partial cross sections 70Zn(n,g)71Zn-m and 70Zn(n,g)71Zn-g...

  6. Abundance of lanthanoids in rock salts determined by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Honda, Teruyuki; Nozaki, Tetsuya [Musashi Inst. of Tech., Kawasaki, Kanagawa (Japan). Atomic Energy Research Lab.; Yui, Mitsuaki; Kikawada, Yoshikazu; Oi, Takao

    1998-06-01

    Contents of lanthanoids (Ln`s) of rock salts have been measured by the neutron activation analysis. Original salt samples were treated in advance of neutron irradiation so that Ln`s were enriched and amounts of interfering nuclides were reduced. The contents of Ln`s were at ppt-sub ppb levels and were comparable with or slightly lower than those of solar salts. The Ln abundance patterns of the salts were those with relative depletion in the heavy Ln`s, thus having negative slopes. It was indicated that, when salt deposit was formed, Ln`s were taken up by anhydrite more preferentially than by halite. (author)

  7. Radiochemical neutron activation analysis for certification of ion-implanted phosphorus in silicon.

    Science.gov (United States)

    Paul, Rick L; Simons, David S; Guthrie, William F; Lu, John

    2003-08-15

    A radiochemical neutron activation analysis procedure has been developed, critically evaluated, and shown to have the necessary sensitivity, chemical specificity, matrix independence, and precision to certify phosphorus at ion implantation levels in silicon. 32P, produced by neutron capture of 31P, is chemically separated from the sample matrix and measured using a beta proportional counter. The method is used here to certify the amount of phosphorus in SRM 2133 (Phosphorus Implant in Silicon Depth Profile Standard) as (9.58 +/- 0.16) x 10(14) atoms x cm(-2). A detailed evaluation of uncertainties is given.

  8. Neutron-Activation Analysis of Biological Material with High Radiation Levels

    Energy Technology Data Exchange (ETDEWEB)

    Samsahl, K.

    1966-09-15

    A method has been developed for the chemical separation and subsequent gamma-spectrometric analysis of the alkali metals, the alkaline earths, the rare earths, chromium, hafnium, lanthanum, manganese, phosphorus, scandium and silver in neutron-activated biological material. The separation steps, being fully automatic, are based on a combination of ion-exchange and partition chromatography and require 40 min.

  9. Research activities on structure materials of spallation neutron source at SINQ

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, G.S.; Dai, Y. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    With the growing interests on powerful spallation neutron sources, especially with liquid metal targets, and accelerator driven energy systems, spallation materials science and technology have been received wide attention. At SINQ, material research activities are focused on: a) liquid metal corrosion; b) radiation damage; and c) interaction of corrosion and radiation damage. (author) 1 fig., refs.

  10. Archaeologist looks at x-ray fluorescence vs. neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Artzy, M.

    1976-04-01

    X-ray fluorescence (XRE) and neutron activation analysis (NAA) are compared; a periodic table of the elements showing their sensitivity to each method is included. It is proposed to use both methods to make chemical abundances measurements on archaeological samples, including Bichrome Ware and Palestinian samples. The intent is to see if NAA can be replaced by XRF. (DLC)

  11. The determination of platinum in tissue of different human organs by means of neutron activation analysis

    DEFF Research Database (Denmark)

    Rietz, Bernd; Heydorn, Kaj; Krarup-Hansen, Anders

    2002-01-01

    . It was demonstrated that radiochemical neutron activation analysis can be used for these studies because of its sensitivity and precision and a low detection limit for platinum (similar to1 ng). Tissues of the following organs were analyzed for platinum: liver, kidney, testis, lung, pancreas and muscle. This study...

  12. A package for gamma-ray spectrum analysis and routine neutron activation analysis

    Indian Academy of Sciences (India)

    M E Medhat; A Abdel-Hafiez; Z Awaad; M A Ali

    2005-08-01

    A package for gamma spectrum analysis (PGSA) was developed using object oriented Borland C++ design for MS-windows. This package consists of five programs which can be used for gamma-ray spectrum analysis and routine neutron activation analysis. The advantages of PGSA are its simple algorithms and its need for only minimum amount of input information.

  13. Dose profile modeling of Idaho National Laboratory's active neutron interrogation laboratory.

    Science.gov (United States)

    Chichester, D L; Seabury, E H; Zabriskie, J M; Wharton, J; Caffrey, A J

    2009-06-01

    A new laboratory has been commissioned at Idaho National Laboratory for performing active neutron interrogation research and development. The facility is designed to provide radiation shielding for deuterium-tritium (DT) fusion (14.1 MeV) neutron generators (2 x 10(8) n/s), deuterium-deuterium (DD) fusion (2.5 MeV) neutron generators (1 x 10(7) n/s), and (252)Cf spontaneous fission neutron sources (6.96 x 10(7) n/s, 30 microg). Shielding at the laboratory is comprised of modular concrete shield blocks 0.76 m thick with tongue-in-groove features to prevent radiation streaming, arranged into one small and one large test vault. The larger vault is designed to allow operation of the DT generator and has walls 3.8m tall, an entrance maze, and a fully integrated electrical interlock system; the smaller test vault is designed for (252)Cf and DD neutron sources and has walls 1.9 m tall and a simple entrance maze. Both analytical calculations and numerical simulations were used in the design process for the building to assess the performance of the shielding walls and to ensure external dose rates are within required facility limits. Dose rate contour plots have been generated for the facility to visualize the effectiveness of the shield walls and entrance mazes and to illustrate the spatial profile of the radiation dose field above the facility and the effects of skyshine around the vaults.

  14. Thick activation detectors for neutron spectrometry using different unfolding methods: sensitivity analysis and dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Medkour Ishak-Boushaki, Ghania, E-mail: gmedkour@yahoo.com [Laboratoire SNIRM-Faculte de Physique, Universite des Sciences et de la Technologie Houari Boumediene, BP 32 El-Alia BabEzzouar, Algiers (Algeria); Boukeffoussa, Khelifa [Laboratoire SNIRM-Faculte de Physique, Universite des Sciences et de la Technologie Houari Boumediene, BP 32 El-Alia BabEzzouar, Algiers (Algeria); Idiri, Zahir [Centre de Recherche Nucleaire d' Alger, 02 Boulevard Frantz-Fanon, BP 399, Algiers (Algeria); Allab, Malika [Laboratoire SNIRM-Faculte de Physique, Universite des Sciences et de la Technologie Houari Boumediene, BP 32 El-Alia BabEzzouar, Algiers (Algeria)

    2012-03-15

    This paper discusses the use of threshold detectors of extended sizes for low intensity neutron fields' characterization. The detectors were tested by the measurement of the neutron spectrum of an {sup 241}Am-Be source. Integral quantities characterizing the neutron field, required for radiological protection, have been derived by unfolding the measured data. A good agreement is achieved between the obtained results and those deduced using Bonner spheres. In addition, a sensitivity analysis of the results to the deconvolution procedure is given. - Highlights: Black-Right-Pointing-Pointer Low intensity neutron fields' characterization using thick threshold detectors. Black-Right-Pointing-Pointer Low activity {sup 241}Am-Be neutron source spectrum measurement. Black-Right-Pointing-Pointer Integral quantities required for radiological protection have been derived. Black-Right-Pointing-Pointer The results are in good agreement with those deduced using Bonner spheres. Black-Right-Pointing-Pointer The results are not very sensitive to the chosen deconvolution procedure.

  15. Design studies related to an in vivo neutron activation analysis facility for measuring total body nitrogen.

    Science.gov (United States)

    Stamatelatos, I E; Chettle, D R; Green, S; Scott, M C

    1992-08-01

    Design studies relating to an in vivo prompt capture neutron activation analysis facility measuring total body nitrogen are presented. The basis of the design is a beryllium-graphite neutron collimator and reflector configuration for (alpha, n) type radionuclide neutron sources (238PuBe or 241AmBe), so as to reflect leaking, or out-scattered, neutrons towards the subject. This improves the ratio of thermal neutron flux to dose and the spatial distribution of thermal flux achieved with these sources, whilst retaining their advantage of long half-lives as compared to 252Cf based systems. The common problem of high count-rate at the detector, and therefore high nitrogen region of interest background due to pile-up, is decreased by using a set of smaller (5.1 cm diameter x 10.2 cm long) NaI(Tl) detectors instead of large ones. The facility described presents a relative error of nitrogen measurement of 3.6% and a nitrogen to background ratio of 2.3 for 0.45 mSv skin dose (assuming ten 5.1 cm x 10.2 cm NaI(Tl) detectors).

  16. Design studies related to an in vivo neutron activation analysis facility for measuring total body nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Stamatelatos, I.E.M.; Chettle, D.R.; Green, S.; Scott, M.C. (Birmingham Univ. (United Kingdom). School of Physics and Space Research)

    1992-08-01

    Design studies relating to an in vivo prompt capture neutron activation analysis facility measuring total body nitrogen are presented. The basis of the design is a beryllium-graphite neutron collimator and reflector configuration for ({alpha}, n) type radionuclide neutron sources ({sup 238}PuBe or {sup 241}AmBe), so as to reflect leaking, or out-scattered, neutrons towards the subject. This improves the ratio of thermal neutron flux to dose and the spatial distribution of thermal flux achieved with these sources, whilst retaining their advantage of long half-lives as compared to {sup 252}Cf based systems. The common problem of high count-rate at the detector, and therefore high nitrogen region of interest background due to pile-up, is decreased by using a set of smaller (5.1 cm diameter x 10.2 cm long) NaI(Tl) detectors instead of large ones. The facility described presents a relative error of nitrogen measurement of 3.6% and a nitrogen to background ratio of 2.3 for 0.45 mSv skin dose (assuming ten 5.1 cm x 10.2 cm NaI(Tl) detectors). (author).

  17. The fast neutron fluence and the activation detector activity calculations using the effective source method and the adjoint function

    Energy Technology Data Exchange (ETDEWEB)

    Hep, J.; Konecna, A.; Krysl, V.; Smutny, V. [Calculation Dept., Skoda JS plc, Orlik 266, 31606 Plzen (Czech Republic)

    2011-07-01

    This paper describes the application of effective source in forward calculations and the adjoint method to the solution of fast neutron fluence and activation detector activities in the reactor pressure vessel (RPV) and RPV cavity of a VVER-440 reactor. Its objective is the demonstration of both methods on a practical task. The effective source method applies the Boltzmann transport operator to time integrated source data in order to obtain neutron fluence and detector activities. By weighting the source data by time dependent decay of the detector activity, the result of the calculation is the detector activity. Alternatively, if the weighting is uniform with respect to time, the result is the fluence. The approach works because of the inherent linearity of radiation transport in non-multiplying time-invariant media. Integrated in this way, the source data are referred to as the effective source. The effective source in the forward calculations method thereby enables the analyst to replace numerous intensive transport calculations with a single transport calculation in which the time dependence and magnitude of the source are correctly represented. In this work, the effective source method has been expanded slightly in the following way: neutron source data were performed with few group method calculation using the active core calculation code MOBY-DICK. The follow-up neutron transport calculation was performed using the neutron transport code TORT to perform multigroup calculations. For comparison, an alternative method of calculation has been used based upon adjoint functions of the Boltzmann transport equation. Calculation of the three-dimensional (3-D) adjoint function for each required computational outcome has been obtained using the deterministic code TORT and the cross section library BGL440. Adjoint functions appropriate to the required fast neutron flux density and neutron reaction rates have been calculated for several significant points within the RPV

  18. Apparatus for the measurement of total body nitrogen using prompt neutron activation analysis with californium-252.

    Science.gov (United States)

    Mackie, A; Hannan, W J; Smith, M A; Tothill, P

    1988-01-01

    Details of clinical apparatus designed for the measurement of total body nitrogen (as an indicator of body protein), suitable for the critically ill, intensive-care patient are presented. Californium-252 radio-isotopic neutron sources are used, enabling a nitrogen measurement by prompt neutron activation analysis to be made in 40 min with a precision of +/- 3.2% for a whole body dose equivalent of 0.145 mSv. The advantages of Californium-252 over alternative neutron sources are discussed. A comparison between two irradiation/detection geometries is made, leading to an explanation of the geometry adopted for the apparatus. The choice of construction and shielding materials to reduce the count rate at the detectors and consequently to reduce the pile-up contribution to the nitrogen background is discussed. Salient features of the gamma ray spectroscopy system to reduce spectral distortion from pulse pile-up are presented.

  19. Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust

    Science.gov (United States)

    Wallace, William T.; Jeevarajan, Antony S.

    2012-01-01

    This sensor unit is designed to determine the level of activation of lunar dust or simulant particles using a fluorescent technique. Activation of the surface of a lunar soil sample (for instance, through grinding) should produce a freshly fractured surface. When these reactive surfaces interact with oxygen and water, they produce hydroxyl radicals. These radicals will react with a terephthalate diluted in the aqueous medium to form 2-hydroxyterephthalate. The fluorescence produced by 2-hydroxyterephthalate provides qualitative proof of the activation of the sample. Using a calibration curve produced by synthesized 2-hydroxyterephthalate, the amount of hydroxyl radicals produced as a function of sample concentration can also be determined.

  20. Piezoelectric sensor characteristics of electro-active paper

    Science.gov (United States)

    Lee, Ho Cheol; Kim, Heung Soo; Yun, Gyu Young; Kim, Jaehwan

    2009-03-01

    The possibility as a vibration sensor of Electro-Active paper (EAPap) based on piezoelectricity was investigated in the present paper. The EAPap was fabricated by regenerating and tape casting cellulose. The sample was coated by thin laminating film for packaging. The capacitance of EAPap was measured and compared with commercial PVDF. Relative permittivity of EAPap was 12, which was same as commercially available PVDF. This reveals that EAPap has similar sensing potential of synthetic piezo polymer film. The simple aluminum cantilevered beam was used for the vibration testing and EAPap was attached on the beam. The original EAPap sensor without grounding and shielding has greatly affected by the surrounding noise such as power noise especially. The power noise reduced dramatically with grounding and shielding of EAPap. The impulsive response of EAPap provided correct dynamic characteristics of the beam. Especially, twisting mode of the beam was clearly observed even though the EAPap was attached at the center of the beam. This is because the sensing capability of EAPap is based on piezoelectricity which is bidirectional strain characteristics. EAPap sensor based on piezoelectricity provided a great potential as a vibration sensor.

  1. Active sensors for health monitoring of aging aerospace structures

    Energy Technology Data Exchange (ETDEWEB)

    GIURGIUTIU,VICTOR; REDMOND,JAMES M.; ROACH,DENNIS P.; RACKOW,KIRK A.

    2000-02-29

    A project to develop non-intrusive active sensors that can be applied on existing aging aerospace structures for monitoring the onset and progress of structural damage (fatigue cracks and corrosion) is presented. The state of the art in active sensors structural health monitoring and damage detection is reviewed. Methods based on (a) elastic wave propagation and (b) electro-mechanical (E/M) impedance technique are cited and briefly discussed. The instrumentation of these specimens with piezoelectric active sensors is illustrated. The main detection strategies (E/M impedance for local area detection and wave propagation for wide area interrogation) are discussed. The signal processing and damage interpretation algorithms are tuned to the specific structural interrogation method used. In the high-frequency E/M impedance approach, pattern recognition methods are used to compare impedance signatures taken at various time intervals and to identify damage presence and progression from the change in these signatures. In the wave propagation approach, the acousto-ultrasonic methods identifying additional reflection generated from the damage site and changes in transmission velocity and phase are used. Both approaches benefit from the use of artificial intelligence neural networks algorithms that can extract damage features based on a learning process. Design and fabrication of a set of structural specimens representative of aging aerospace structures is presented. Three built-up specimens (pristine, with cracks, and with corrosion damage) are used. The specimen instrumentation with active sensors fabricated at the University of South Carolina is illustrated. Preliminary results obtained with the E/M impedance method on pristine and cracked specimens are presented.

  2. Compressive Sleeping Wireless Sensor Networks With Active Node Selection

    OpenAIRE

    Chen, Wei; Wassell, Ian J.

    2014-01-01

    This is the author accepted manuscript. The final version is available from IEEE via http://dx.doi.org/10.1109/GLOCOM.2014.7036776 In this paper, we propose an active node selection framework for compressive sleeping wireless sensor networks (WSNs) in order to improve the signal acquisition performance and network lifetime. The node selection can be seen as a specialized sensing matrix design problem where the sensing matrix consists of selected rows of an identity matrix. By capitalizing ...

  3. Neutron Albedo

    CERN Document Server

    Ignatovich, V K

    2005-01-01

    A new, algebraic, method is applied to calculation of neutron albedo from substance to check the claim that use of ultradispersive fuel and moderator of an active core can help to gain in size and mass of the reactor. In a model of isotropic distribution of incident and reflected neutrons it is shown that coherent scattering on separate grains in the case of thermal neutrons increases transport cross section negligibly, however it decreases albedo from a wall of finite thickness because of decrease of substance density. A visible increase of albedo takes place only for neutrons with wave length of the order of the size of a single grain.

  4. Mobile Soil Moisture Management in High Elevations: Applications of the Cosmic Ray Neutron Sensor Technique for Estimating Field Scale Soil Water Content

    Science.gov (United States)

    Avery, William Alexander; Wahbi, Ammar; Dercon, Gerd; Heng, Lee; Franz, Trenton; Strauss, Peter

    2017-04-01

    Meeting the demands of a growing global population is one of the principal challenges of the 21st century. Meeting this challenge will require an increase in food production around the world. Currently, approximately two thirds of freshwater use by humans is devoted to agricultural production. As such, an expansion of agricultural activity will place additional pressure on freshwater resources. The incorporation of novel soil moisture sensing technologies into agricultural practices carries the potential to make agriculture more precise thus increasing water use efficiency. One such technology is known as the Cosmic Ray Neutron Sensor (CRNS). The CRNS technique is capable of quantifying soil moisture on a large spatial scale ( 30 ha) compared with traditional point based in-situ soil moisture sensing technology. Recent years have seen the CRNS to perform well when deployed in agricultural environments at low to mid elevations. However, the performance of the CRNS technique in higher elevations, particularly alpine environments, has yet to be demonstrated or understood. Mountainous environments are more vulnerable to changing climates and land use practices, yet are often responsible for the headwaters of major river systems sustaining cultivated lands or support important agricultural activity on their own. As such, the applicability of a mobile version of the CRNS technology in high alpine environments needs to be explored. This research details the preliminary efforts to determine if established calibration and validation techniques associated with the use of the CRNS can be applied at higher elevations. Field work was conducted during the summer of 2016 in the mountains of western Austria. Initial results indicate that the relationship between in-situ soil moisture data determined via traditional soil sampling and soil moisture data determined via the mobile CRNS is not clear. It is possible that the increasing intensity of incoming cosmic rays at higher

  5. Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, H. [PBI-Dansensor A/S (Denmark); Toft Soerensen, O. [Risoe National Lab., Materials Research Dept. (Denmark)

    1999-10-01

    A new type of ceramic oxygen sensors based on semiconducting oxides was developed in this project. The advantage of these sensors compared to standard ZrO{sub 2} sensors is that they do not require a reference gas and that they can be produced in small sizes. The sensor design and the techniques developed for production of these sensors are judged suitable by the participating industry for a niche production of a new generation of oxygen sensors. Materials research on new oxygen ion conducting conductors both for applications in oxygen sensors and in fuel was also performed in this project and finally a new process was developed for fabrication of ceramic tubes by dip-coating. (EHS)

  6. Sensors

    CERN Document Server

    Pigorsch, Enrico

    1997-01-01

    This is the 5th edition of the Metra Martech Directory "EUROPEAN CENTRES OF EXPERTISE - SENSORS." The entries represent a survey of European sensors development. The new edition contains 425 detailed profiles of companies and research institutions in 22 countries. This is reflected in the diversity of sensors development programmes described, from sensors for physical parameters to biosensors and intelligent sensor systems. We do not claim that all European organisations developing sensors are included, but this is a good cross section from an invited list of participants. If you see gaps or omissions, or would like your organisation to be included, please send details. The data base invites the formation of effective joint ventures by identifying and providing access to specific areas in which organisations offer collaboration. This issue is recognised to be of great importance and most entrants include details of collaboration offered and sought. We hope the directory on Sensors will help you to find the ri...

  7. Conception, realization and test of an electronic Si-LiF-Si sensor for neutron spectrometry and dosimetry; Conception, realisation et test d'un capteur electronique Si-Lif-Si destine a la spectrometrie et a la dosimetrie des neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Ndoye Gueye, A

    1998-07-01

    The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)

  8. High-fidelity MCNP modeling of a D-T neutron generator for active interrogation of special nuclear material

    Science.gov (United States)

    Katalenich, Jeff; Flaska, Marek; Pozzi, Sara A.; Hartman, Michael R.

    2011-10-01

    Fast and robust methods for interrogation of special nuclear material (SNM) are of interest to many agencies and institutions in the United States. It is well known that passive interrogation methods are typically sufficient for plutonium identification because of a relatively high neutron production rate from 240Pu [1]. On the other hand, identification of shielded uranium requires active methods using neutron or photon sources [2]. Deuterium-deuterium (2.45 MeV) and deuterium-tritium (14.1 MeV) neutron-generator sources have been previously tested and proven to be relatively reliable instruments for active interrogation of nuclear materials [3,4]. In addition, the newest generators of this type are small enough for applications requiring portable interrogation systems. Active interrogation techniques using high-energy neutrons are being investigated as a method to detect hidden SNM in shielded containers [4,5]. Due to the thickness of some containers, penetrating radiation such as high-energy neutrons can provide a potential means of probing shielded SNM. In an effort to develop the capability to assess the signal seen from various forms of shielded nuclear materials, the University of Michigan Neutron Science Laboratory's D-T neutron generator and its shielding were accurately modeled in MCNP. The generator, while operating at nominal power, produces approximately 1×10 10 neutrons/s, a source intensity which requires a large amount of shielding to minimize the dose rates around the generator. For this reason, the existing shielding completely encompasses the generator and does not include beam ports. Therefore, several MCNP simulations were performed to estimate the yield of uncollided 14.1-MeV neutrons from the generator for active interrogation experiments. Beam port diameters of 5, 10, 15, 20, and 25 cm were modeled to assess the resulting neutron fluxes. The neutron flux outside the beam ports was estimated to be approximately 2×10 4 n/cm 2 s.

  9. The D-D Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Active Well Coincidence Counter

    Energy Technology Data Exchange (ETDEWEB)

    McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cleveland, Steven L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    The 235U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques due to the limited penetration of the item by the characteristic 235U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Collar (UNCL) and 252Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252Cf shuffler systems rely on the use of high-output 252Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every five to seven years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. In this work, we made use of Oak Ridge National Laboratory’s (ORNL’s) Large Volume Active Well Coincidence Counter (LV-AWCC) and a commercially available deuterium-deuterium (D-D) neutron generator to examine the potential of the D-D neutron generator as an alternative to the isotopic sources. We present the performance of the LV-AWCC with D-D generator for the assay of 235U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium (DU), low enriched uranium (LEU), and highly enriched uranium (HEU) items.

  10. Results from the CDE phase activity on neutron dosimetry for the international fusion materials irradiation facility test cell

    CERN Document Server

    Esposito, B; Maruccia, G; Petrizzi, L; Bignon, G; Blandin, C; Chauffriat, S; Lebrun, A; Recroix, H; Trapp, J P; Kaschuck, Y

    2000-01-01

    The international fusion materials irradiation facility (IFMIF) project deals with the study of an accelerator-based, deuterium-lithium source, producing high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials for fusion energy reactors. IFMIF would also provide calibration and validation of data from fission reactor and other accelerator based irradiation tests. This paper describes the activity on neutron/gamma dosimetry (necessary for the characterization of the specimens' irradiation) performed in the frame of the IFMIF conceptual design evaluation (CDE) neutronics tasks. During the previous phase (conceptual design activity (CDA)) the multifoil activation method was proposed for the measurement of the neutron fluence and spectrum and a set of suitable foils was defined. The cross section variances and covariances of this set of foils have now been used for tests on the sensitivity of the IFMIF neutron spectrum determination to cross section uncertainties...

  11. Evaluation of Hylife-II and Sombrero using 175- and 566- group neutron transport and activation cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, D; Latkowski, J; Sanz, J

    1999-06-18

    Recent modifications to the TART Monte Carlo neutron and photon transport code enable calculation of 566-group neutron spectra. This expanded group structure represents a significant improvement over the 50- and 175-group structures that have been previously available. To support use of this new capability, neutron activation cross section libraries have been created in the 175- and 566-group structures starting from the FENDL/A-2.0 pointwise data. Neutron spectra have been calculated for the first walls of the HYLIFE-II and SOMBRERO inertial fusion energy power plant designs and have been used in subsequent neutron activation calculations. The results obtained using the two different group structures are compared to each other as well as to those obtained using a 175-group version of the EAF3.1 activation cross section library.

  12. Evaluation of HYLIFE-II and Sombrero using 175- and 566-group neutron transport and activation cross sections

    CERN Document Server

    Latkowski, J F; Sanz, J

    2000-01-01

    Recent modifications to the TART Monte Carlo neutron and photon transport code allow enable calculation of 566-group neutron spectra. This expanded group structure represents a significant improvement over the 50- and 175-group structures that have been previously available. To support use of this new capability, neutron activation cross-section libraries have been created in the 175- and 566-group structures starting from the FENDL/A-2.0 pointwise data. Neutron spectra have been calculated for the first walls of the HYLIFE-II and Sombrero inertial fusion energy power plant designs and have been used in subsequent neutron activation calculations. The results obtained using the two different group structures are compared with each other as well as to those obtained using a 175-group version of the EAF3.1 activation cross-section library.

  13. Cyclic neutron activation for non-destructive characterization of radioactive waste; Zyklische Neutronen-Aktivierung zur Zerstoerungsfreien Charakterisierung radioaktiver Abfaelle

    Energy Technology Data Exchange (ETDEWEB)

    Havenith, Andreas; Kettler, John [RWTH Aachen (Germany). Inst. fuer Nuklearen Brennstoffkreislauf; Mauerhofer, Eric [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Energie und Klimaforschung

    2011-07-01

    In Germany about 100.000 casks with low-level radioactive waste are actually stored in federal collection sites or at the nuclear power plants. Due to the incomplete documentation these casks have to be characterized with respect to their composition. In order to avoid the opening of the casks a new non-destructive characterization method was developed by the authors based on the prompt and delayed gamma-neutron-activation analyses using 14 MeV neutrons. the main challenge was to determine the self-shielding of neutrons and photons dependent on the sample composition. Computerized MNCP calculations and experiments were performed. The multi-element analysis is based on the gamma spectroscopy during neutron activation. A new measuring system (MEDINA - multi-element detection based on instrumental neutron activation) was built esp. for the characterization of 200-l casks used in the repository KONRAD.

  14. Software for neutron activation analysis at reactor IBR-2, FLNP, JINR

    CERN Document Server

    Zlokazov, V B

    2004-01-01

    A Delphi program suite, developed for processing gamma-spectra of induced activity of nuclei, obtained from the neutron activation measurements at the reactor IBR-2, FLNF, JINR, is reported. This suite contains components, intended for carrying out all the operations of the analysis cycle, starling with a data acquisition program for gamma -spectrometers Gamma (written in C++ Builder) and including Delphi programs for steps of the analysis. (6 refs).

  15. Analysis of the neutron component at high altitude mountains using active and passive measurement devices

    CERN Document Server

    Hajek, M; Schoener, W; Vana, N

    2002-01-01

    The European Council directive 96/29/Euratom requires dosimetric precautions if the effective dose exceeds 1 mSv/a. On an average, this value is exceeded by aircrew members. Roughly half of the radiation exposure at flight altitudes is caused by cosmic ray-induced neutrons. Active ( sup 6 LiI(Eu)-scintillator) and passive (TLDs) Bonner sphere spectrometers were used to determine the neutron energy spectra atop Mt. Sonnblick (3105 m) and Mt. Kitzsteinhorn (3029 m). Further measurements in a mixed radiation field at CERN as well as in a proton beam of 62 MeV at Paul Scherrer Institute, Switzerland, confirmed that not only neutrons but also charged particles contribute to the readings of active detectors, whereas TLD-600 and TLD-700 in pair allow the determination of the thermal neutron flux. Unfolding of the detector data obtained atop both mountains shows two relative maxima around 1 MeV and 85 MeV, which have to be considered for the assessment of the biologically relevant dose equivalent. By convoluting the ...

  16. Development of a prompt gamma activation analysis facility using diffracted polychromatic neutron beam

    CERN Document Server

    Byun, S H; Choi, H D

    2002-01-01

    A prompt gamma activation analysis facility has recently been developed at Hanaro, the 24 MW research reactor in the Korea Atomic Energy Research Institute. Polychromatic thermal neutrons are extracted by setting pyrolytic graphite crystals at a Bragg angle of 45 deg. . The detection system comprises a large single n-type HPGe detector, signal electronics and a fast ADC. Neutron beam characterization was performed both theoretically and experimentally. The neutron flux was measured to be 7.9x10 sup 7 n/cm sup 2 s in a 1x1 cm sup 2 beam area at the sample position with a uniformity of 12%. The corresponding Cd-ratio for gold was found to be 266. The beam quality was compared with other representative thermal neutron prompt gamma activation analysis. The detection efficiency was calibrated up to 11 MeV using a set of radionuclides and the (n,gamma) reactions of N and Cl. Finally, the sensitivities and the detection limits were obtained for several elements.

  17. Proton Neutron Gamma-X Detection (PNGXD): An introduction to contrast agent detection during proton therapy via prompt gamma neutron activation

    Science.gov (United States)

    Gräfe, James L.

    2017-09-01

    Proton therapy is an alternative external beam cancer treatment modality to the conventional linear accelerator-based X-ray radiotherapy. An inherent by-product of proton-nuclear interactions is the production of secondary neutrons. These neutrons have long been thought of as a secondary contaminant, nuisance, and source of secondary cancer risk. In this paper, a method is proposed to use these neutrons to identify and localize the presence of the tumor through neutron capture reactions with the gadolinium-based MRI contrast agent. This could provide better confidence in tumor targeting by acting as an additional quality assurance tool of tumor position during treatment. This effectively results in a neutron induced nuclear medicine scan. Gadolinium (Gd), is an ideal candidate for this novel nuclear contrast imaging procedure due to its unique nuclear properties and its widespread use as a contrast agent in MRI. Gd has one of the largest thermal neutron capture cross sections of all the stable nuclides, and the gadolinium-based contrast agents localize in leaky tissues and tumors. Initial characteristics of this novel concept were explored using the Monte Carlo code MCNP6. The number of neutron capture reactions per Gy of proton dose was found to be approximately 50,000 neutron captures/Gy, for a 8 cm3 tumor containing 300 ppm Gd at 8 cm depth with a simple simulation designed to represent the active delivery method. Using the passive method it is estimated that this number can be up to an order of magnitude higher. The thermal neutron distribution was found to not be localized within the spread out Bragg peak (SOBP) for this geometrical configuration and therefore would not allow for the identification of a geometric miss of the tumor by the proton SOBP. However, this potential method combined with nuclear medicine imaging and fused with online CBCT and prior MRI or CT imaging could help to identify tumor position during treatment. More computational and

  18. Computational investigation of the neutron shielding and activation characteristics of borated concrete with polyethylene aggregate

    Energy Technology Data Exchange (ETDEWEB)

    Park, S.J.; Jang, J.G.; Lee, H.K., E-mail: leeh@kaist.ac.kr

    2014-09-15

    This paper presents the result of a computational study to investigate the neutron shielding and activation characteristics of concretes containing boron carbide and polyethylene. Various mixes were considered with changes in the contents of boron carbide and polyethylene aggregate. The Monte Carlo simulation code MCNP-5 was utilized to determine the transmission of neutron through concrete at different energies from 0.1 eV to 1 MeV, and ORIGEN-S code was then used to predict activation characteristics of the concretes. It was shown that the replacement of polyethylene in borated concrete greatly enhanced the shielding efficiency of the concrete, and total activity levels of the concrete were considerably decreased with this replacement. Furthermore, double-layered structures having the first layer of polyethylene aggregate-replaced concrete and the second layer of 2 wt% borated concrete are shown to improve shielding efficiency more significantly than monolithic structures.

  19. 16 CFR 1211.13 - Inherent force activated secondary door sensors.

    Science.gov (United States)

    2010-01-01

    ... sensors. 1211.13 Section 1211.13 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... § 1211.13 Inherent force activated secondary door sensors. (a) Normal operation test. (1) A force activated door sensor of a door system installed according to the installation instructions shall actuate...

  20. Review of current neutron detection systems for emergency response

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Guss, Paul; Kruschwitz, Craig

    2014-09-01

    Neutron detectors are used in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 (3He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 (10B), lithium-6 (6Li), and gadollinium-157 (157Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 (4He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

  1. Active pixel sensors in AMS H18/H35 HV-CMOS technology for the ATLAS HL-LHC upgrade

    Science.gov (United States)

    Ristic, Branislav

    2016-09-01

    Deep sub micron HV-CMOS processes offer the opportunity for sensors built by industry standard techniques while being HV tolerant, making them good candidates for drift-based, fast collecting, thus radiation-hard pixel detectors. For the upgrade of the ATLAS Pixel Detector towards the HL-LHC requirements, active pixel sensors in HV-CMOS technology were investigated. These implement signal processing electronics in deep n-wells, which also act as collecting electrodes. The deep n-wells allow for bias voltages up to 150 V leading to a depletion depth of several 10 μm. Prototype sensors in the AMS H18 180 nm and H35 350 nm HV-CMOS processes were thoroughly tested in lab measurements as well as in testbeam experiments. Irradiations with X-rays and protons revealed a tolerance to ionizing doses of 1 Grad while Edge-TCT studies assessed the effects of radiation on the charge collection. The sensors showed high detection efficiencies after neutron irradiation to 1015neq cm-2 in testbeam experiments. A full reticle size demonstrator chip, implemented in the H35 process is being submitted to prove the large scale feasibility of the HV-CMOS concept.

  2. Development of an accelerator driven neutron activator for medical radioisotope production

    Science.gov (United States)

    Abbas, K.; Buono, S.; Burgio, N.; Cotogno, G.; Gibson, N.; Maciocco, L.; Mercurio, G.; Santagata, A.; Simonelli, F.; Tagziria, H.

    2009-04-01

    A compact, accelerator driven, neutron activator based on a modified version of the Adiabatic Resonance Crossing (ARC) concept has been developed, with the aim of efficiently utilising ion-beam generated neutrons for the production of radioactive nanoparticles for brachytherapy. Extensive Monte Carlo simulations have been carried out to optimise the design of the activator, which is based on a hybrid approach, coupling a lead buffer and a graphite reflector. Computational Fluid Dynamic methods have been used for the thermal-hydraulic design of the neutron-generating beryllium target to ensure efficient water cooling under high proton beam currents. The facility has been tested under various experimental configurations, and the activation yields of different materials, measured with γ-spectrometry techniques, have been compared with theoretical predictions. In this paper the main elements of the activator are described, and calculated and measured results for pure Au, Mo, Ho, and Re foils as well as for Re and Ho nanoparticle samples are presented. A satisfactory agreement between experiment and theory was found, confirming that the improved ARC activator developed in this work is suitable for isotope production for certain applications such as brachytherapy.

  3. Deuteron and neutron induced activation in the Eveda accelerator materials: implications for the accelerator maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M.; Sanz, J.; Garcia, N.; Cabellos, O. [Madrid Univ. Politecnica, C/ Jose Gutierrez Abascal, lnstituto de Fusion Nuclear (Spain); Sauvan, R. [Universidad Nacional de Educacion a Distancia (UNED), Madrid (Spain); Moreno, C.; Sedano, L.A. [CIEMAT-Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, Association Euratom-CIEMAT, Madrid (Spain)

    2007-07-01

    Full text of publication follows: The IFMIF (International Fusion Materials Irradiation Facility) is an accelerator-based DLi neutron source designed to test fusion reactor candidate materials for high fluence neutrons. Before deciding IFMIF construction, an engineering design and associated experimental data acquisition, defined as EVEDA, has been proposed. Along the EVEDA accelerator, deuteron beam losses collide with the accelerator materials, producing activation and consequent radiations responsible of dose. Calculation of the dose rates in the EVEDA accelerator room is necessary in order to analyze the feasibility for manual maintenance. Dose rates due to the activation produced by the deuteron beam losses interaction with the accelerator materials, will be calculated with the ACAB activation code, using EAF2007 library for deuteron activation cross-sections. Also, dose rates from the activation induced by the neutron source produced by the interaction of deuteron beam losses with the accelerator materials and the deuterium implanted in the structural lattice, will be calculated with the SRIM2006, TMAP7, DROSG2000/NEUYIE, MCNPX and ACAB codes. All calculations will be done for the EVEDA accelerator with the room temperature DTL structure, which is based on copper cavities for the DTL. Some calculations will be done for the superconducting DTL structure, based on niobium cavities for the DTL working at cryogenic temperature. Final analysis will show the dominant mechanisms and major radionuclides contributing to the surface dose rates. (authors)

  4. Optical Breath Gas Sensor for Extravehicular Activity Application

    Science.gov (United States)

    Wood, William R.; Casias, Miguel E.; Vakhtin, Andrei B.; Pilgrim, Jeffrey S.; Chullen, Cinda; Falconi, Eric A.; McMillin, Summer

    2013-01-01

    The function of the infrared gas transducer used during extravehicular activity in the current space suit is to measure and report the concentration of carbon dioxide (CO2) in the ventilation loop. The next generation portable life support system (PLSS) requires next generation CO2 sensing technology with performance beyond that presently in use on the Space Shuttle/International Space Station extravehicular mobility unit (EMU). Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. A laser diode spectrometer based on wavelength modulation spectroscopy is being developed for this purpose by Vista Photonics, Inc. Two prototype devices were delivered to NASA Johnson Space Center (JSC) in September 2011. The sensors incorporate a laser diode-based CO2 channel that also includes an incidental water vapor (humidity) measurement and a separate oxygen channel using a vertical cavity surface emitting laser. Both prototypes are controlled digitally with a field-programmable gate array/microcontroller architecture. The present development extends and upgrades the earlier hardware to the Advanced PLSS 2.0 test article being constructed and tested at JSC. Various improvements to the electronics and gas sampling are being advanced by this project. The combination of low power electronics with the performance of a long wavelength laser spectrometer enables multi-gas sensors with significantly increased performance over that presently offered in the EMU.

  5. A CMOS Active Pixel Sensor for Charged Particle Detection

    Energy Technology Data Exchange (ETDEWEB)

    Matis, Howard S.; Bieser, Fred; Kleinfelder, Stuart; Rai, Gulshan; Retiere, Fabrice; Ritter, Hans George; Singh, Kunal; Wurzel, Samuel E.; Wieman, Howard; Yamamoto, Eugene

    2002-12-02

    Active Pixel Sensor (APS) technology has shown promise for next-generation vertex detectors. This paper discusses the design and testing of two generations of APS chips. Both are arrays of 128 by 128 pixels, each 20 by 20 {micro}m. Each array is divided into sub-arrays in which different sensor structures (4 in the first version and 16 in the second) and/or readout circuits are employed. Measurements of several of these structures under Fe{sup 55} exposure are reported. The sensors have also been irradiated by 55 MeV protons to test for radiation damage. The radiation increased the noise and reduced the signal. The noise can be explained by shot noise from the increased leakage current and the reduction in signal is due to charge being trapped in the epi layer. Nevertheless, the radiation effect is small for the expected exposures at RHIC and RHIC II. Finally, we describe our concept for mechanically supporting a thin silicon wafer in an actual detector.

  6. Method of demonstrating calcium in human foot by neutron activation of (. cap alpha. , N)-sources

    Energy Technology Data Exchange (ETDEWEB)

    Zaychik, V.E.; Kondrashov, A.E.; Morukov, B.V.

    Bone demineralization during long-term exposure to weightlessness and hypokinesia is presently a universally recognized fact. A method is described which employs neutron activation analysis for a direct quantitative in vivo assay of calcium in the human foot. When the foot is exposed to neutrons, the stable nuclide Ca/sup 46/ is converted into the radionuclide Ca/sup 49/. The gamma radiation emitted by Ca/sup 49/ is then measured spectrometrically. A special device, developed for the delivery of neutrons to the foot, consists of a stainless steel tank filled with water, surrounded on the side by lithium-containing screens. A cassette with neutron sources is at the bottom of the tank and can be delivered to the desired position in channel-driver carriers. A special footrest provides support during irradiation. The spectrometry unit, consisting of 4 scintillation counters, also is equipped with a specially designed footrest. The maximum relative error of a single measurement did not exceed 4.82%. The mean equivalent dose in the foot was about 1 rem, a dose low enough to permit examinations three times a year, if necessary.

  7. Field Prototype of the ENEA Neutron Active Interrogation Device for the Detection of Dirty Bombs

    Directory of Open Access Journals (Sweden)

    Nadia Cherubini

    2016-10-01

    Full Text Available The Italian National Agency for New Technologies, Energy, and Sustainable Economic Development (ENEA Neutron Active Interrogation (NAI device is a tool designed to improve CBRNE defense. It is designed to uncover radioactive and nuclear threats including those in the form of Improvised Explosive Devices (IEDs, the so-called “dirty bombs”. The NAI device, at its current development stage, allows to detect 6 g of 235U hidden in a package. It is easily transportable, light in weight, and with a real-time response. Its working principle is based on two stages: (1 an “active” stage in which neutrons are emitted by a neutron generator to interact with the item under inspection, and (2 a “passive” stage in which secondary neutrons are detected originating a signal that, once processed, allows recognition of the offence. In particular, a clear indication of the potential threat is obtained by a dedicated software based on the Differential Die-Away Time Analysis method.

  8. A multi-layered active target for the study of neutron-unbound nuclides at NSCL

    Science.gov (United States)

    Freeman, Jessica; Gueye, Paul; Redpath, Thomas; MoNA Collaboration

    2017-01-01

    The characteristics of neutron-unbound nuclides were investigated using a multi-layered Si/Be active target designed for use with the MoNA/LISA setup at the National Superconducting Cyclotron (NSCL). The setup consists of the MoNA/LISA arrays (for neutron detection) and a superconducting sweeper magnet (for charged separation) to identify products following the decay of neutron unbound states. The segmented target consisted of three 700 mg/cm2 beryllium targets and four 0.14 mm thick 62x62 mm2 silicon detectors. As a commissioning experiment for the target the decay of two-neutron unbound 26O populated in a one-proton removal reaction from a radioactive 27F beam was performed. The 27F secondary radioactive beam from the NSCL's Coupled Cyclotron Facility was produced from the fragmentation of a 140 MeV/u 48Ca beam incident on a thick beryllium target and then cleanly selected by the A1900 fragment separator. The energy loss and position spectra of the incoming beam and reaction products were used to calibrate the Silicon detectors to within 1.5% in both energy and position. A dedicated Geant4 model of the target was developed to simulate the energy loss within the target. A description of the experimental setup, simulation work, and energy and position calibration will be presented. DoE/NNSA - DE-NA0000979.

  9. A New Quantum Sensor for Measuring Photosynthetically Active Radiation

    Science.gov (United States)

    Johnson, D.; Thomas, T.; Heinicke, D.; Peterson, R.; Morgan, P.; McDermitt, D. K.; Burba, G. G.

    2015-12-01

    A quantum sensor measures photosynthetically active radiation (PAR, in μmol of photons m-2 s-1) in the 400 nm to 700 nm waveband. Plants utilize this radiation to drive photosynthesis, though individual plant responses to incident radiation may vary within this range. The new quantum sensor (model LI-190R, LI-COR Biosciences, Lincoln, NE), with an optical filter and silicon photodiode detector housed in a cosine-corrected head, is designed to provide a better response to incident radiation across the 400-700 nm range. The new design is expected to significantly improve spectral response due to uniformity across the PAR waveband, but particularly in the wavebands from 520 nm to 600 nm and 665 nm to 680 nm, and sharp cutoffs in the regions below and above the PAR waveband. Special care was taken to make sure that PAR sensor would not substantially respond to incident radiation above the 700 nm threshold because this can lead to errors when performing measurements in environments with a large proportion of near-infrared radiation, such as canopy understory. The physical housing of the sensor is designed to be weather-resistant, to effectively shed precipitation, provide protection at high temperature and high humidity conditions, and has a cosine-corrected response to 82° zenith angle. The latter is particularly important when measuring incident radiation at low elevation angles, diffuse light, or low light conditions. This presentation describes the principles of the new design, and shows the performance results from field experiments and laboratory tests.

  10. Determination of the neutron activation profile of core drill samples by gamma-ray spectrometry.

    Science.gov (United States)

    Gurau, D; Boden, S; Sima, O; Stanga, D

    2017-08-04

    This paper provides guidance for determining the neutron activation profile of core drill samples taken from the biological shield of nuclear reactors using gamma spectrometry measurements. Thus, it provides guidance for selecting a model of the right form to fit data and using least squares methods for model fitting. The activity profiles of two core samples taken from the biological shield of a nuclear reactor were determined. The effective activation depth and the total activity of core samples along with their uncertainties were computed by Monte Carlo simulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Verification of the viability of virions detection using neutron activation analysis; Verificacao da viabilidade de deteccao de virions atraves da analise por ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Wacha, R.; Silva, A.X. da; Crispim, V.R [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear; Couceiro, J.N.S.S. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Microbiologia Professor Paulo de Goes. Dept. de Virologia

    2002-07-01

    The use of nuclear techniques, as Neutron Activation Analysis, can be an alternative way for the microbiological diagnosis, bringing a significant profit in the analysis time, for not needing pre cultivated samples in appropriate way. In this technique, the samples are collected and submitted to a thermal neutron beam. The interaction of these neutrons with the samples generates gamma rays whose energy spectre is a characteristic of the elemental composition of these samples. Of this done one, a virus presence can be detected in the sample through the distinction of its respective elemental compositions allowing, also, carrying through the analysis in real time. In this work, computational simulations had been become fulfilled using the radiation transport code based on the Monte Carlo Method, MCNP4B, to verify the viability of the application of this system for the virus particle detection in its natural collection environment. (author)

  12. Reproducibility of neutron activated Sm-153 oral dose formulations intended for human administration

    Energy Technology Data Exchange (ETDEWEB)

    Yeong, C.H. [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Blackshaw, P.E. [Medical Physics and Clinical Engineering, Nottingham University Hospitals NHS Trust, Nottingham NG7 2UH (United Kingdom); Ng, K.H.; Abdullah, B.J.J. [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Blaauw, M. [Reactor Institute Delft, Faculty of Applied Sciences, Delft University of Technology, 2628 CJ Delft (Netherlands); Dansereau, R.J. [Procter and Gamble Pharmaceuticals, 8700 Mason-Montgomery Rd, Mason (United States); Perkins, A.C., E-mail: alan.perkins@nottingham.ac.uk [Medical Physics and Clinical Engineering, Nottingham University Hospitals NHS Trust, Nottingham NG7 2UH (United Kingdom); Radiological and Imaging Sciences and Nottingham Digestive Diseases Biomedical Research Unit, University of Nottingham, Nottingham NG7 2UH (United Kingdom)

    2011-09-15

    Neutron activation of Sm-152 offers a method of radiolabeling for the in vivo study of oral dose formulations by gamma scintigraphy. Reproducibility measurements are needed to ensure the robustness of clinical studies. 204 enteric-coated guaifenesin core tablets (10 mg of Sm{sub 2}O{sub 3}) were irradiated by thermal neutrons to achieve 1 MBq at 48 h. Administered activities were 0.86{+-}0.03 MBq. Good reproducibility (CV=3.5%) was observed over 24 weeks ensuring that volunteer doses were within the dose reference level of 0.8 mSv. - Highlights: > 204 enteric-coated guaifenesin core tablets were irradiated by thermal neutrons. > Activity measured at 48 h after irradiation was 1.01{+-}0.03 MBq. > Activity administered per subject was 0.88{+-}0.03 MBq. > Good reproducibility (CV=3.5%) of Sm-153 radioactivity was obtained. > Effective doses to volunteers were within dose reference level of 0.8 mSv.

  13. A History of In Vivo Neutron Activation Analysis in Measurement of Aluminum in Human Subjects.

    Science.gov (United States)

    Mohseni, Hedieh K; Chettle, David R

    2016-01-01

    Aluminum, as an abundant metal, has gained widespread use in human life, entering the body predominantly as an additive to various foods and drinking water. Other major sources of exposure to aluminum include medical, cosmetic, and occupational routes. As a common environmental toxin, with well-known roles in several medical conditions such as dialysis encephalopathy, aluminum is considered a potential candidate in the causality of Alzheimer's disease. Aluminum mostly accumulates in the bone, which makes bone an indicator of the body burden of aluminum and an ideal organ as a proxy for the brain. Most of the techniques developed for measuring aluminum include bone biopsy, which requires invasive measures, causing inconvenience for the patients. There has been a considerable effort in developing non-invasive approaches, which allow for monitoring aluminum levels for medical and occupational purposes in larger populations. In vivo neutron activation analysis, a method based on nuclear activation of isotopes of elements in the body and their subsequent detection, has proven to be an invaluable tool for this purpose. There are definite challenges in developing in vivo non-invasive techniques capable of detecting low levels of aluminum in healthy individuals and aluminum-exposed populations. The following review examines the method of in vivo neutron activation analysis in the context of aluminum measurement in humans focusing on different neutron sources, interference from other activation products, and the improvements made in minimum detectable limits and patient dose over the past few decades.

  14. Measurements of 60Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999.

    Science.gov (United States)

    Gasparro, J; Hult, M; Komura, K; Arnold, D; Holmes, L; Johnston, P N; Laubenstein, M; Neumaier, S; Reyss, J-L; Schillebeeckx, P; Tagziria, H; Van Britsom, G; Vasselli, R

    2004-01-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes gamma-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring (60)Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from (60)Co activity is in agreement with previous measurements using the short-lived radionuclides (51)Cr and (59)Fe. Limits on contamination of the samples with (60)Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using (60)Co activation.

  15. The affect of industrial activities on zinc in alluvial Egyptian soil determined using neutron activation analysis

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Thirty-two surface (0-20 cm) soil samples were collected from different locations in Egypt representing non-polluted,moderately and highly polluted soils.The aim of this study was to evaluate total Zn content in alluvial soils of Nile Delta in Egypt by using the delayed neutron activation analysis technique (DNAA),in the irradiation facilities of the first Egyptian research reactor (ET-RR-1).The gamma-ray spectra were recorded with a hyper pure germanium detection system.The well resolved gamma-ray peak at 1116.0 kev was efficiently used for 65Zn content determination.Zn content in non-polluted soil samples ranged between 74.1 and 103.8 ppm with an average of 98.5 + 5.1 ppm.Zn content in moderately polluted soils ranged between 136.0 and 232.5 ppm with an average of 180.1 + 32.6 ppm.The highest Zn levels ranging from 240.0 and 733.0 ppm with an average of 410.3 + 54.4 ppm,were observed in soil samples collected from,either highly polluted agricultural soils exposed to prolonged irrigation with industrial wastewater or surface soil samples from industrial sites.

  16. The affect of industrial activities on zinc in alluvial Egyptian soil determined using neutron activation analysis.

    Science.gov (United States)

    Abdel-Sabour, M F; Abdel-Basset, N

    2002-07-01

    Thirty-two surface (0-20 cm) soil samples were collected from different locations in Egypt representing non-polluted, moderately and highly polluted soils. The aim of this study was to evaluate total Zn content in alluvial soils of Nile Delta in Egypt by using the delayed neutron activation analysis technique (DNAA), in the irradiation facilities of the first Egyptian research reactor (ET-RR-1). The gamma-ray spectra were recorded with a hyper pure germanium detection system. The well resolved gamma-ray peak at 1116.0 keV was efficiently used for 65Zn content determination. Zn content in non-polluted soil samples ranged between 74.1 and 103.8 ppm with an average of 98.5 +/- 5.1 ppm. Zn content in moderately polluted soils ranged between 136.0 and 232.5 ppm with an average of 180.1 +/- 32.6 ppm. The highest Zn levels ranging from 240.0 and 733.0 ppm with an average of 410.3 +/- 54.4 ppm, were observed in soil samples collected from, either highly polluted agricultural soils exposed to prolonged irrigation with industrial wastewater or surface soil samples from industrial sites.

  17. Neutron activation analysis and atomic absorption spectrophotometry for the analysis of fresh, pasteurised and powder milk

    Energy Technology Data Exchange (ETDEWEB)

    Wasim, M.; Rehman, S.; Arif, M.; Fatima, I.; Zaidi, J.H. [Pakistan Inst. of Nuclear Science and Technology, Islamabad (Pakistan). Chemistry Div.

    2012-07-01

    This study shows the application of semi-absolute k{sub 0} instrumental neutron activation analysis (k{sub 0}-INAA), epithermal neutron activation analysis (ENAA) and atomic absorption spectrophotometry (AAS) for the determination of 21 elements (Br, Ca, Cl, Co, Cr, Cs, Cu, Fe, Hf, I, K, Mg, Mn, Na, Ni, P, Pb, Rb, Sc Sr, and Zn) in different types of milk samples. The ENAA was required for the determination of iodine, AAS for Cu, Ni and Pb and the rest of the elements were measured by k{sub 0}-INAA. Thirteen elements (Br, Ca, Cl, Cs, Cu, Fe, K, Mg, Na, P, Rb, Sr and Zn) were identified in all milk samples. Ni was detected in eleven and Pb in two samples. Concentrations of most of the elements were within the ranges of the world reported data. The data was further explored by principal component analysis to find relationships between samples and elements. (orig.)

  18. Uncertainties in measuring trace amounts of cobalt and europium with low-flux neutron activation analysis

    Directory of Open Access Journals (Sweden)

    Burnham Steven

    2017-01-01

    Full Text Available Neutron activation analysis is widely used for identification of elements and their quantities even in trace amounts in the samples of almost any type. The challenges in detecting trace amounts of particular elements are often associated with the neutron flux produced at the research reactors. Low-flux neutron activation analysis usually presents the biggest challenge when analyzing trace quantities of elements with lower magnitude of radiative capture cross-sections. In this paper, we present the methodology and the quantified uncertainties associated with the detection of trace amounts of cobalt and europium, using as an example concrete aggregates. Recent growing interest is in improving structural concrete (increasing its strength but reducing its activation in nuclear power plant environments. Aside from buildings, structural concrete is also used as a biological shield in nuclear power plant that become radioactive after exposure to neutron flux. Due to radiative capture interactions, artificial radionuclides are generated to high enough concentrations that classify concrete as low-level radioactive waste at the time of the plant's decommissioning. Disposal of this concrete adds to the expense of nuclear power plant financing and its construction. Three radionuclides, 60Co, 152Eu, and 154Eu, account for 99 % of total residual radioactivity of nuclear power plant decommissioned concrete. IAEA document RS-G-1.7, Application of the Concepts of Exclusion, Exemption, and Clearance, specifies clearance levels of radionuclides specific activities: a specific activity lower than 0.1 Bqg-1 for 60Co and 152Eu, and 154Eu allows for a concrete to be recycled after decommissioning of the nuclear power plant. Therefore, low-flux neutron activation analysis is used to test the detection limits of trace elements in samples of cement, coarse, and fine concrete aggregates. These samples are irradiated at the University of Utah's 100 kW TRIGA Reactor at

  19. Elemental analysis of rain- and fresh water by neutron activation analysis

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Analysis of rain-and fresh water for trace constituents is a manda tory part of environmental monitoring. This text gives a survey of neutron activation analysis (NAA) within the framework of current environmental water research pro grammes, based on the practice developed in co-operation with the Dutch Energy Research Centre at Petten (ECN). While the procedures reported in literature cover about thirty five elements, our routine procedures of instrumental neutron activation analysis (INAA) is limited to ten to fifteen elements. The use of some dedicated ra diochemical separations (RNAA) adds another six, some of which are speciated as well. Current contributions of NAA to water analysis center on determination and speciation of anionic trace elements, notably Br, I, As. and Se, on the assay of some ultra traces like Ag, Au and Hg and on validation.

  20. Heavy metals in the benthic animals from hydrothermal vents: Results of neutron activation analysis

    Science.gov (United States)

    Shmelev, I. P.; Kuznetsov, A. A.; Galkin, S. V.

    2009-06-01

    A series of samples of inhabitants of hydrothermal vents were collected during the 12th cruise of R/V Akademik Mstislav Keldysh in Guaymas Basin (the Gulf of California) and the Axial Seamount area (Juan de Fuca Ridge). The concentrations of trace and heavy metals in the tissues of Ridgeia piscesae, Riftia pachyptila, and Paralvinella palmiformis were analyzed. The neutron-activation analysis revealed significantly higher concentrations of uranium in the tissues of Paralvinella palmiformis as compared to the ambient seawater. The possible reasons for such phenomenon are discussed. The data obtained by the neutron-activation method are compared with those obtained by the atomic-absorption method for the same tissues analyzed.

  1. Neutron flux variations near the Earth’s crust. A possible tectonic activity detection

    Directory of Open Access Journals (Sweden)

    B. M. Kuzhevskij

    2003-01-01

    Full Text Available The present work contains some results of observations of neutron flux variations near the Earth’s surface. The Earth’s crust is determined to be a significant source of thermal and slow neutrons, originated from the interaction between the nuclei of the elements of the Earth’s crust and the atmosphere and α-particles, produced by decay of radioactive gases (Radon, Thoron and Actinon. In turn, variations of radioactive gases exhalation is connected with geodynamical processes in the Earth’s crust, including tectonic activity. This determined relation between the processes in the Earth’s crust and neutrons’ flux allow to use variations of thermal and slow neutrons’ flux in order to observe increasing tectonic activity and to develop methods for short-term prediction of natural hazards.

  2. A neutron activation analysis procedure for the determination of uranium, thorium and potassium in geologic samples

    Science.gov (United States)

    Aruscavage, P. J.; Millard, H.T.

    1972-01-01

    A neutron activation analysis procedure was developed for the determination of uranium, thorium and potassium in basic and ultrabasic rocks. The three elements are determined in the same 0.5-g sample following a 30-min irradiation in a thermal neutron flux of 2??1012 n??cm-2??sec-1. Following radiochemical separation, the nuclides239U (T=23.5 m),233Th (T=22.2 m) and42K (T=12.36 h) are measured by ??-counting. A computer program is used to resolve the decay curves which are complex owing to contamination and the growth of daughter activities. The method was used to determine uranium, throium and potassium in the U. S. Geological Survey standard rocks DTS-1, PCC-1 and BCR-1. For 0.5-g samples the limits of detection for uranium, throium and potassium are 0.7, 1.0 and 10 ppb, respectively. ?? 1972 Akade??miai Kiado??.

  3. New Active Digital Pixel Circuit for CMOS Image Sensor

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A new active digital pixel circuit for CMOS image sensor is designed consisting of four components: a photo-transducer, a preamplifier, a sample & hold (S & H) circuit and an A/D converter with an inverter. It is optimized by simulation and adjustment based on 2μm standard CMOS process. Each circuit of the components is designed with specific parameters. The simulation results of the whole pixel circuits show that the circuit has such advantages as low distortion, low power consumption, and improvement of the output performances by using an inverter.

  4. Activation foils unfolding for neutron spectrometry: Comparison of different deconvolution methods

    Energy Technology Data Exchange (ETDEWEB)

    Tripathy, S.P. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India)], E-mail: sam.tripathy@gmail.com; Sunil, C. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India); Nandy, M. [Saha Institute of Nuclear Physics, 1/AF Bidhan Nagar, Kolkata 700064 (India); Sarkar, P.K. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India); Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700064 (India); Sharma, D.N. [Radiation Safety Systems Division, BARC, Mumbai 400085 (India); Mukherjee, B. [Deutsches Elektronen-Synchrotron, LLRF Group, D-22607 Hamburg (Germany)

    2007-12-21

    The results obtained from the activation foils measurement are unfolded using two different deconvolution methods such as BUNKI and genetic algorithm (GA). The spectra produced by these codes agree fairly with each other and are comparable with that measured previously for the same system using NE213 liquid scintillator and by unfolding the neutron-induced proton pulse height distribution using two different methods, viz. FERDOR and BUNKI. The details of various unfolding procedures used in this work are reported in this paper.

  5. Utilization of ko-factors for quality assurance in neutron activation analysis

    DEFF Research Database (Denmark)

    Heydorn, K.; Damsgaard, E.

    1994-01-01

    Multielement certification analysis by instrumental neutron activation analysis requires simultaneous irradiation of several elemental comparator standards in order to ascertain traceability. Internal consistency of different comparators may be checked by calculation of k0-ratios, which show large...... deviations from unity in case of stoichiometric or other gross errors. Quality assurance based on the Analysis of Precision of k0-ratios from replicate analyses detects unexpected variability associated with inaccurate comparator standards. In two actual cases of cerification lack of statistical control...

  6. Identification of the provenience of Majolica from sites in the Caribbean using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Olin, J.S.; Sayre, E.V.

    1975-01-01

    Tin-enamelled earthenware pottery from five early Spanish Colonial sites in the Dominican Republic and Venezuela were sampled and analyzed by neutron activation analysis in an attempt to determine whether these sherds had a common source. The tentative conclusion was that although several sources were indicated for the specimens analyzed the overall similarity in composition indicated that these sources were probably closely related. (JSR)

  7. An application of a simple computer program for neutron activation analysis

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A simple computer program is designed for estimation of elemental concentration values in complex samples by neutron activation analysis technique. The program is applied for an Egyptian cement sample which irradiated at the Egyptian Research Reactor-1(ET-RR-1). The data obtained is compared with the reported values. The time consumed for such calculations has a remarkable reduction in comparison with the routine work.

  8. Rapid determination of halogenes in milk by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Alfassi, Z.B.; Lavi, N.

    1985-07-01

    The absolute concetrations of iodine, bromine and chlorine in milk were determined by epithermal neutron activation followed by high resolution gamma-ray spectrometry. Two kinds of milk commonly consumed in Israel were investigated. The concentration of iodine, bromine and chlorine were found to be 0.18-0.30 ..mu..g/ml, 2.02-2.85 ..mu..g/ml and 0.65 mg/ml, respectively. The method is fast, selective, accurate and highly sensitive.

  9. Radiochemical neutron activation analysis of rare earth elements in peridotitic rocks

    Energy Technology Data Exchange (ETDEWEB)

    Joron, J.L. (Laboratoire d' Analyse par Activation Pierre Sue, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)); Ottonello, G. (Consiglio Nationale delle Ricerche, Pisa (Italy). Ist. di Petrografia)

    1985-02-01

    A radiochemical neutron activation analytical method based on various methods published earlier was used to determine rare earth elements (REE). The method involves a post-irradiation sample fusion, two separate ion-exchange chromatographic stages, and, finally, a fluoride precipitation. The RNAA procedure is capable of providing very precise REE data for peridotitic samples and was used for the analysis of rocks from several geodynamic environments.

  10. Instrumental neutron activation analysis of soil and sediment samples from Siwa Oasis, Egypt

    Science.gov (United States)

    Badawy, Wael M.; Ali, Khaled; El-Samman, Hussein M.; Frontasyeva, Marina V.; Gundorina, Svetlana F.; Duliu, Octavian G.

    2015-07-01

    Instrumental neutron activation analysis was used to study geochemical peculiarities of the Siwa Oasis in the Western Egyptian Desert. A total of 34 elements were determined in soil and sediment samples (Na, Mg, Al, Cl, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Zn, As, Br, Rb, Sr, Zr, Sb, I, Cs, Ba, La, Ce, Nd, Eu, Tb, Dy, Tm, Yb, Hf, Ta, Th, and U). For data interpretation Cluster analysis was applied. Comparison with the available literature data was carried out.

  11. Event based neutron activation spectroscopy and analysis algorithm using MLE and metaheuristics

    OpenAIRE

    Wallace Barton

    2014-01-01

    Techniques used in neutron activation analysis are often dependent on the experimental setup. In the context of developing a portable and high efficiency detection array, good energy resolution and half-life discrimination are difficult to obtain with traditional methods [1] given the logistic and financial constraints. An approach different from that of spectrum addition and standard spectroscopy analysis [2] was needed. The use of multiple detectors prompts the need for a flexible storage o...

  12. Salvinia auriculata: Aquatic bioindicator studied by instrumental neutron activation analysis (INAA)

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Soares, Daniel Cristian; Figueiredo de Oliveira, Ester [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Avenida Antonio Carlos, 6627 Pampulha, CEP 30123-970 Belo Horizonte, Minas Gerais (Brazil); Fatima Silva, Gracia Divina de; Duarte, Lucienir Pains [Departamento de Quimica, ICEx, Nucleo de estudos de Plantas Medicinais (NEPLAM), Universidade Federal de Minas Gerais, Avenida Antonio Carlos, 6627 Pampulha, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Pott, Vali Joana [Empresa Brasileira de Agropecuaria (EMBRAPA), BR 262 km 4, Caixa Postal 154, CEP 79002-970 Campo Grande, Mato Grosso do Sul (Brazil); Vieira Filho, Sidney Augusto [Escola de Farmacia, DEFAR, Universidade Federal de Ouro Preto, Rua Costa Sena, 171, CEP 35400-000 Ouro Preto, Minas Gerais (Brazil)], E-mail: bibo@ef.ufop.br

    2008-05-15

    Through instrumental neutron activation analysis (INAA) the elemental chemical composition of Salvinia auriculata and Ouro Preto city public water was determined. Elements Ce, Th, Cr, Hf, Sb, Sc, Rb, Fe, Zn, Co, Au, La and Br were quantified. High chromium concentration was determined in this plant. But, chromium was determined only in low concentrations in the water. The results indicate the great capacity of this plant to absorb and accumulate inorganic elements.

  13. Application of neutron activation in hydrometallurgical process of lead chloride extraction from boulangerit

    OpenAIRE

    Zovko Emira; Islamović Safija

    2010-01-01

    In this work, a neutron activation analysis for the identification of radiochemical elements in the ore concentrate of zone Vareš, Bosnia and Hercegovina, has been applied. The possibility of dissolving ore concentrate from iron(III) chloride was examined. To follow the dissolving lead (II) sulphide yield from the ore concentrates, in addition to radioisotope labeling process, it is necessary to use a gravimetric analysis of the extracted lead(II) chloride. Based on kinetic measurements of di...

  14. Revision and extensions of neutron capture cross-sections in the European activation file EAF-3

    Energy Technology Data Exchange (ETDEWEB)

    Kopecky, J.; Delfini, M.G.; Kamp, H.A.J. van der; Nierop, D.

    1992-07-01

    This report contains an extensive description of the work performed to compile, extend and revise the neutron capture data subfile of the European Activation File (EAF-3). The starter was the EAF-1 data file from 1989. The present version, EAF/NG-3, contains (n, [gamma]) excitation functions for all nuclides (729 targets) with half-lives exceeding 1/2 day in the mass range from H-1 to Cm-248. (author). 35 refs.; 9 figs.; 7 tabs.

  15. An application of a simple computer program for neutron activation analysis.

    Science.gov (United States)

    Abdel Basset, N

    2001-01-01

    A simple computer program is designed for estimation of elemental concentration values in complex samples by neutron activation analysis technique. The program is applied for an Egyptian cement sample which irradiated at the Egyptian Research Reactor-1(ET-RR-1). The data obtained is compared with the reported values. The time consumed for such calculations has a remarkable reduction in comparison with the routine work.

  16. Neutron activation analysis in archaeological and solar energy research; Neutronenaktivierungsanalyse in Archaeometrie und Solarenergieforschung

    Energy Technology Data Exchange (ETDEWEB)

    Stieghorst, Christian

    2016-06-23

    For 80 years now, neutron activation analysis (NAA) has been providing reliable data of the elemental composition for different materials in various scientific fields. Today, there are still many applications for NAA, and new methods based on neutron activation were developed during the last couple of years. In this work the focus was on the precise elemental analysis of different materials. For the provenance studies of ancient Roman limestone objects the elemental composition of samples and quarries were compared by using geochemical indicators and multivariate statistics of the elemental composition dataset, which was previously produced by using instrumental neutron activation analysis (INAA). The samples of this work originated from different archeological sites and quarries in the French region of Lorraine as well as samples from excavations in the Belgian city of Tongeren. Various objects could successfully assign to one of the Lorraine quarries via principle component analysis (PCA) and support vector machines (SVM).The aim of the co-operation between the Fraunhofer Institute for Solar Energy Systems ISE in Freiburg, Germany, and the Institute of Nuclear Chemistry in Mainz, Germany, was to reduce the energy and cost consumption during the production process of multicrystalline solar cells at a constant efficiency level. The test ingots were produced at the ISE and measured with NAA. The colleagues' work on this topic was focused on INAA measurements of the 3d transition metals and a new developed method for phosphorus detection. In this work prompt-gamma neutron activation analysis (PGAA) was used to measure the dopand boron as well as hydrogen. The PGAA facility of the FRM II reactor close to the city of Munich was used for this purposes. For the measurement of boron amounts below the PGAA detection limit in the medium ppb{sub w}-range a new method developed at the FRM II by Lichtinger was tested. A qualitative boron detection was successful.

  17. A neutron activation system for Ho, HoZr and Sm brachytherapy seeds for breast radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Wagner L., E-mail: wagner.leite@ifmg.edu.br [Instituto Federal de Minas Gerais (IFMG), Congonhas, MG (Brazil). Departamento de Fisica; Campos, Tarcisio P.R., E-mail: tprcampos@pq.cnpq.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2015-07-01

    This paper addresses a device designed for transmuting nuclides by means of neutron capture reactions. The device is composed by a neutron generator based on d-d reactions, a neutron moderator and a reflection system, enclosed by a radiation shield. The project was modeled on the CST electromagnetic code. Afterwards, a nuclear investigation was carried out by MCNP5 code, where the final activities of a large set of 0.5 x 1.8 mm cylindrical, biodegradable and biocompatible, Ho-165 (Ho and HoZr) and Sm-152 breast brachytherapy seeds were evaluated, considering the neutron capture reactions. The accelerator-head equipotential profiles and the optical beam of deuterons with its energy map were presented. The neutronic evaluation allowed estimating a neutron yield of 10{sup 13} n s{sup -1}. From the seed's group, an individual Ho-166 seed reached activity of 100 MBq in 58 h operation time. Moreover, Sm-153 seed reached 120 MBq during a period of 64 h of operation. The system shows to be able to provide the neutron activation of brachytherapy seeds with suitable individual specific activity able for controlling breast tumors. (author)

  18. A Monolithic Active Pixel Sensor for ionizing radiation using a 180 nm HV-SOI process

    Science.gov (United States)

    Hemperek, Tomasz; Kishishita, Tetsuichi; Krüger, Hans; Wermes, Norbert

    2015-10-01

    An improved SOI-MAPS (Silicon On Insulator Monolithic Active Pixel Sensor) for ionizing radiation based on thick-film High Voltage SOI technology (HV-SOI) has been developed. Similar to existing Fully Depleted SOI-based (FD-SOI) MAPS, a buried silicon oxide inter-dielectric (BOX) layer is used to separate the CMOS electronics from the handle wafer which is used as a depleted charge collection layer. FD-SOI MAPS suffers from radiation damage such as transistor threshold voltage shifts due to charge traps in the oxide layers and charge states created at the silicon oxide boundaries (back gate effect). The X-FAB 180-nm HV-SOI technology offers an additional isolation by deep non-depleted implant between the BOX layer and the active circuitry which mitigates this problem. Therefore we see in this technology a high potential to implement radiation-tolerant MAPS with fast charge collection property. The design and measurement results from a first prototype are presented including charge collection in neutron irradiated samples.

  19. Fissile materials in solution concentration measured by active neutron interrogation; Mesure de concentration en matiere fissile dans les liquides par interrogation neutronique active

    Energy Technology Data Exchange (ETDEWEB)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-12-31

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a {sup 252} Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.). 6 refs.

  20. Radiography apparatus using gamma rays emitted by water activated by fusion neutrons

    Science.gov (United States)

    Smith, D.L.; Ikeda, Yujiro; Uno, Yoshitomo

    1996-11-05

    Radiography apparatus includes an arrangement for circulating pure water continuously between a location adjacent a source of energetic neutrons, such as a tritium target irradiated by a deuteron beam, and a remote location where radiographic analysis is conducted. Oxygen in the pure water is activated via the {sup 16}O(n,p){sup 16}N reaction using {sup 14}N-MeV neutrons produced at the neutron source via the {sup 3}H(d,n){sup 4}He reaction. Essentially monoenergetic gamma rays at 6.129 (predominantly) and 7.115 MeV are produced by the 7.13-second {sup 16}N decay for use in radiographic analysis. The gamma rays have substantial penetrating power and are useful in determining the thickness of materials and elemental compositions, particularly for metals and high-atomic number materials. The characteristic decay half life of 7.13 seconds of the activated oxygen is sufficient to permit gamma ray generation at a remote location where the activated water is transported, while not presenting a chemical or radioactivity hazard because the radioactivity falls to negligible levels after 1--2 minutes. 15 figs.

  1. Progress report on neutron activation analysis at Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tuan, Nguyen Ngoc [Nuclear Research Institute, Dalat (Viet Nam)

    2003-03-01

    Neutron Activation Analysis (NAA) is one of most powerful techniques for the simultaneous multi-elements analysis. This technique has been studied and applied to analyze major, minor and trace elements in Geological, Biological and Environmental samples at Dalat Nuclear Research Reactor. At the sixth Workshop, February 8-11, 1999, Yojakarta, Indonesia we had a report on Current Status of Neutron Activation Analysis using Dalat Nuclear Research Reactor. Another report on Neutron Activation Analysis at the Dalat Nuclear Research Reactor also was presented at the seventh Workshop in Taejon, Korea from November 20-24, 2000. So in this report, we would like to present the results obtained of the application of NAA at NRI for one year as follows: (1) Determination of the concentrations of noble, rare earth, uranium, thorium and other elements in Geological samples according to requirement of clients particularly the geologists, who want to find out the mineral resources. (2) The analysis of concentration of radionuclides and nutrient elements in foodstuffs to attend the program on Asian Reference Man. (3) The evaluation of the contents of trace elements in crude oil and basement rock samples to determine original source of the oil. (4) Determination of the elemental composition of airborne particle in the Ho Chi Minh City for studying air pollution. The analytical data of standard reference material, toxic elements and natural radionuclides in seawater are also presented. (author)

  2. Measurement and theoretical estimation of induced activity in natIn by high energy neutrons

    Indian Academy of Sciences (India)

    Maitreyee Nandy; P K Sarkar; N Nakao; T Shibata

    2009-10-01

    Induced radioactivity in natural indium (natIn) foils by high energy neutrons was measured at the KENS Facility, KEK, Japan, where a 16.7 cm thick W target was bombarded by protons of 500 MeV. High energy neutrons consequently produced irradiated the In targets placed at different depths inside a 4 m thick concrete shield placed at the beam exit. The measured activities were compared with the results calculated using the nuclear reaction model codes ALICE-91 and EMPIRE-2.18. To estimate the induced activity, excitation functions of the various radionuclides were calculated using the two codes and folded with the appropriate neutron energy distribution at different depths of the concrete shield. The calculated excitation functions of a given nuclide were found to vary widely from one another in some cases. The performances of the codes for different input parameters like level densities and inverse cross-sections are reported in this paper. Our analysis shows that neither of the two codes reproduced all the measured activities satisfactorily, requiring further improvements in the models adopted.

  3. Photoneutron Flux Measurement via Neutron Activation Analysis in a Radiotherapy Bunker with an 18 MV Linear Accelerator

    Directory of Open Access Journals (Sweden)

    Çeçen Yiğit

    2017-01-01

    Full Text Available In cancer treatment, high energy X-rays are used which are produced by linear accelerators (LINACs. If the energy of these beams is over 8 MeV, photonuclear reactions occur between the bremsstrahlung photons and the metallic parts of the LINAC. As a result of these interactions, neutrons are also produced as secondary radiation products (γ,n which are called photoneutrons. The study aims to map the photoneutron flux distribution within the LINAC bunker via neutron activation analysis (NAA using indium-cadmium foils. Irradiations made at different gantry angles (0°, 90°, 180° and 270° with a total of 91 positions in the Philips SLI-25 linear accelerator treatment room and location-based distribution of thermal neutron flux was obtained. Gamma spectrum analysis was carried out with high purity germanium (HPGe detector. Results of the analysis showed that the maximum neutron flux in the room occurred at just above of the LINAC head (1.2x105 neutrons/cm2.s which is compatible with an americium-beryllium (Am-Be neutron source. There was a 90% decrease of flux at the walls and at the start of the maze with respect to the maximum neutron flux. And, just in front of the LINAC door, inside the room, neutron flux was measured less than 1% of the maximum.

  4. Workplace testing of the new single sphere neutron spectrometer based on Dysprosium activation foils (Dy-SSS)

    Science.gov (United States)

    Bedogni, R.; Gómez-Ros, J. M.; Esposito, A.; Gentile, A.; Chiti, M.; Palacios-Pérez, L.; Angelone, M.; Tana, L.

    2012-08-01

    A photon insensitive passive neutron spectrometer consisting of a single moderating polyethylene sphere with Dysprosium activation foils arranged along three perpendicular axes was designed by CIEMAT and INFN. The device is called Dy-SSS (Dy foil-based Single Sphere Spectrometer). It shows nearly isotropic response in terms of neutron fluence up to 20 MeV. The first prototype, previously calibrated with 14 MeV neutrons, has been recently tested in workplaces having different energy and directional distributions. These are a 2.5 MeV nearly mono-chromatic and mono-directional beam available at the ENEA Frascati Neutron Generator (FNG) and the photo-neutron field produced in a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa). Both neutron spectra are known through measurements with a Bonner Sphere Spectrometer. In both cases the experimental response of the Dy-SSS agrees with the reference data. Moreover, it is demonstrated that the spectrometric capability of the new device are independent from the directional distribution of the neutron field. This opens the way to a new generation of moderation-based neutron instruments, presenting all advantages of the Bonner sphere spectrometer without the disadvantage of the repeated exposures. This concept is being developed within the NESCOFI@BTF project of INFN (Commissione Scientifica Nazionale 5).

  5. FY15 Status Report on NEAMS Neutronics Activities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. H. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Smith, M. A. [Argonne National Lab. (ANL), Argonne, IL (United States); Connaway, H. M. [Argonne National Lab. (ANL), Argonne, IL (United States); Aliberti, G. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-30

    This report summarizes the current status of NEAMS activities in FY2015. The tasks this year are (1) to improve solution methods for steady-state and transient conditions, (2) to develop features and user friendliness to increase the usability and applicability of the code, (3) to improve and verify the multigroup cross section generation scheme, (4) to perform verification and validation tests of the code using SFRs and thermal reactor cores, and (5) to support early users of PROTEUS and update the user manuals.

  6. Better physical activity classification using smartphone acceleration sensor.

    Science.gov (United States)

    Arif, Muhammad; Bilal, Mohsin; Kattan, Ahmed; Ahamed, S Iqbal

    2014-09-01

    Obesity is becoming one of the serious problems for the health of worldwide population. Social interactions on mobile phones and computers via internet through social e-networks are one of the major causes of lack of physical activities. For the health specialist, it is important to track the record of physical activities of the obese or overweight patients to supervise weight loss control. In this study, acceleration sensor present in the smartphone is used to monitor the physical activity of the user. Physical activities including Walking, Jogging, Sitting, Standing, Walking upstairs and Walking downstairs are classified. Time domain features are extracted from the acceleration data recorded by smartphone during different physical activities. Time and space complexity of the whole framework is done by optimal feature subset selection and pruning of instances. Classification results of six physical activities are reported in this paper. Using simple time domain features, 99 % classification accuracy is achieved. Furthermore, attributes subset selection is used to remove the redundant features and to minimize the time complexity of the algorithm. A subset of 30 features produced more than 98 % classification accuracy for the six physical activities.

  7. Analysis of human enamel and dentine by neutron activation analysis; Analise de esmalte e dentina de humanos pelo metodo de ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Marco A.B. [Sao Paulo Univ., SP (Brazil). Inst. de Quimica]. E-mail: vankfire@gmail.com; Adachi, Eduardo M.; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2005-07-01

    Determination of trace elements in dental tissues has been of great interest to study the correlation between element composition and caries as well as food habits of individuals. In the present study dentine and enamel samples from healthy individuals were analysed by neutron activation analysis. The teeth were provided form dental clinics, and they were previously washed using purified water and acetone. Then they were dried at 40 deg C and ground in a agate mortar. The samples and element standards were irradiated with thermal neutrons at the IEA-R1 nuclear reactor. Long irradiations of 8 h under thermal neutron flux of 5x10{sup 12} n cm{sup -2} s{sup -1} were used for Ca, Na, Sr and Zn determinations. In short irradiations of 15 s and under neutron flux of 10{sup 12} n cm{sup -2} s{sup -1} the elements Mg, Mn, Na e Sr were determined. The induced gamma activities of the samples and standards were measured using a hyperpure Ge detector coupled to a gamma ray spectrometer. Elemental concentrations were calculated by comparative method. Results obtained showed that Ca, Mg and Na are present in both tissues at the level of percentages and the elements Mn, Sr and Zn at the {mu}g g{sup -1} levels. For quality control of the results the certified reference materials NIST 1400 Bone Ash and NIST 1486 Bone Meal were analysed. (author)

  8. Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

    Energy Technology Data Exchange (ETDEWEB)

    Croft, Stephen [Oak Ridge National Laboratory (ORNL), One Bethel Valley Road, Oak Ridge, TN (United States); Burr, Tom [International Atomic Energy Agency (IAEA), Vienna (Austria); Favalli, Andrea [Los Alamos National Laboratory (LANL), MS E540, Los Alamos, NM 87545 (United States); Nicholson, Andrew [Oak Ridge National Laboratory (ORNL), One Bethel Valley Road, Oak Ridge, TN (United States)

    2016-03-01

    The declared linear density of {sup 238}U and {sup 235}U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar – Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of {sup 235}U (the response) in order to estimate model parameters of the nonlinear Padé equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This paper compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. We find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

  9. Dealing with the Effects of Sensor Displacement in Wearable Activity Recognition

    Directory of Open Access Journals (Sweden)

    Oresti Banos

    2014-06-01

    Full Text Available Most wearable activity recognition systems assume a predefined sensor deployment that remains unchanged during runtime. However, this assumption does not reflect real-life conditions. During the normal use of such systems, users may place the sensors in a position different from the predefined sensor placement. Also, sensors may move from their original location to a different one, due to a loose attachment. Activity recognition systems trained on activity patterns characteristic of a given sensor deployment may likely fail due to sensor displacements. In this work, we innovatively explore the effects of sensor displacement induced by both the intentional misplacement of sensors and self-placement by the user. The effects of sensor displacement are analyzed for standard activity recognition techniques, as well as for an alternate robust sensor fusion method proposed in a previous work. While classical recognition models show little tolerance to sensor displacement, the proposed method is proven to have notable capabilities to assimilate the changes introduced in the sensor position due to self-placement and provides considerable improvements for large misplacements.

  10. Dealing with the Effects of Sensor Displacement in Wearable Activity Recognition

    Science.gov (United States)

    Banos, Oresti; Toth, Mate Attila; Damas, Miguel; Pomares, Hector; Rojas, Ignacio

    2014-01-01

    Most wearable activity recognition systems assume a predefined sensor deployment that remains unchanged during runtime. However, this assumption does not reflect real-life conditions. During the normal use of such systems, users may place the sensors in a position different from the predefined sensor placement. Also, sensors may move from their original location to a different one, due to a loose attachment. Activity recognition systems trained on activity patterns characteristic of a given sensor deployment may likely fail due to sensor displacements. In this work, we innovatively explore the effects of sensor displacement induced by both the intentional misplacement of sensors and self-placement by the user. The effects of sensor displacement are analyzed for standard activity recognition techniques, as well as for an alternate robust sensor fusion method proposed in a previous work. While classical recognition models show little tolerance to sensor displacement, the proposed method is proven to have notable capabilities to assimilate the changes introduced in the sensor position due to self-placement and provides considerable improvements for large misplacements. PMID:24915181

  11. Neutronics and activation analysis of lithium-based ternary alloys in IFE blankets

    Energy Technology Data Exchange (ETDEWEB)

    Jolodosky, Alejandra, E-mail: aleja311@berkeley.edu [University of California Berkeley, Berkeley, CA 94706 (United States); Kramer, Kevin [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA (United States); Meier, Wayne; DeMuth, James; Reyes, Susana [TerraPower, Bellevue, WA 98005 (United States); Fratoni, Massimiliano [University of California Berkeley, Berkeley, CA 94706 (United States)

    2016-06-15

    Highlights: • Monte Carlo calculations were performed on numerous lithium ternary alloys. • Elements with high neutron multiplication performed well with low absorbers. • Enriching lithium decreases minimum lithium concentration of alloys by 60% or more. • Alloys that performed well neutronically were selected for activation calculations. • Alloys activated, except LiBaBi, do not pose major environmental or safety concerns. - Abstract: An attractive feature of using liquid lithium as the breeder and coolant in fusion blankets is that it has very high tritium solubility and results in very low levels of tritium permeation throughout the facility infrastructure. However, lithium metal vigorously reacts with air and water and presents plant safety concerns. The Lawrence Livermore National Laboratory is carrying an effort to develop a lithium-based ternary alloy that maintains the beneficial properties of lithium (e.g. high tritium breeding and solubility) and at the same time reduces overall flammability concerns. This study evaluates the neutronics performance of lithium-based alloys in the blanket of an inertial fusion energy chamber in order to inform such development. 3-D Monte Carlo calculations were performed to evaluate two main neutronics performance parameters for the blanket: tritium breeding ratio (TBR), and the fusion energy multiplication factor (EMF). It was found that elements that exhibit low absorption cross sections and higher q-values such as Pb, Sn, and Sr, perform well with those that have high neutron multiplication such as Pb and Bi. These elements meet TBR constrains ranging from 1.02 to 1.1. However, most alloys do not reach EMFs greater than 1.15. Additionally, it was found that enriching lithium with {sup 6}Li significantly increases the TBR and decreases the minimum lithium concentration by more than 60%. The amount of enrichment depends on how much total lithium is in the alloy to begin with. Alloys that performed well in the TBR

  12. Active hydrothermal and non-active massive sulfide mound investigation using a new multiparameter chemical sensor

    Science.gov (United States)

    Han, C.; Wu, G.; Qin, H.; Wang, Z.

    2012-12-01

    Investigation of active hydrothermal mound as well as non-active massive sulfide mound are studied recently. However, there is still lack of in-situ detection method for the non-active massive sulfide mound. Even though Transient ElectroMagnetic (TEM) and Electric Self-potential (SP) methods are good, they both are labour, time and money cost work. We proposed a new multiparameter chemical sensor method to study the seafloor active hydrothermal mound as well as non-active massive sulfide mound. This sensor integrates Eh, S2- ions concentration and pH electrochemical electrodes together, and could found chemical change caused by the active hydrothermal vent, even weak chemical abnormalities by non-active massive sulfide hydrothermal mound which MARP and CTD sometimes cannot detect. In 2012, the 1st Leg of the Chinese 26th cruise, the multiparameter chemical sensor was carried out with the deepsea camera system over the Carlsberg Ridge in Indian Ocean by R/V DAYANGYIHAO. It was shown small Eh and S2- ions concentration abnormal around a site at Northwest Indian ridge. This site was also evidenced by the TV grab. In the 2nd Leg of the same cruise in June, this chemical sensor was carried out with TEM and SP survey system. The chemical abnormalities are matched very well with both TEM and SP survey results. The results show that the multiparameter chemical sensor method not only can detect active hydrothermal mound, but also can find the non-active massive sulfide hydrothermal mound.

  13. Neutron activation determination of iridium, gold, platinum, and silver in geologic samples

    Science.gov (United States)

    Millard, H.T.

    1987-01-01

    Low-level methods for the determination of iridium and other noble metals have become increasingly important in recent years due to interest in locating abundance anomalies associated with the Cretaceous and Tertiary (K-T) boundary. Typical iridium anomalies are in the range of 1 to 100 ??g/kg (ppb). Thus methods with detection limits near 0.1 ??g/kg should be adequate to detect K-T boundary anomalies. Radiochemical neutron activation analysis methods continue to be required although instrumental neutron activation analysis techniques employing elaborate gamma-counters are under development. In the procedure developed in this study samples irradiated in the epithermal neutron facility of the U. S. Geological Survey TRIGA Reactor (Denver, Colorado) are treated with a mini-fire assay technique. The iridium, gold, and silver are collected in a 1-gram metallic lead button. Primary contaminants at this stage are arsenic and antimony. These can be removed by heating the button with a mixture of sodium perioxide and sodium hydroxide. The resulting 0.2-gram lead bead is counted in a Compton suppression spectrometer. Carrier yields are determined by reirradiation of the lead beads. This procedure has been applied to the U.S.G.S. Standard Rock PCC-1 and samples from K-T boundary sites in the Western Interior of North America. ?? 1987 Akade??miai Kiado??.

  14. Bonding techniques for hybrid active pixel sensors (HAPS)

    Science.gov (United States)

    Bigas, M.; Cabruja, E.; Lozano, M.

    2007-05-01

    A hybrid active pixel sensor (HAPS) consists of an array of sensing elements which is connected to an electronic read-out unit. The most used way to connect these two different devices is bump bonding. This interconnection technique is very suitable for these systems because it allows a very fine pitch and a high number of I/Os. However, there are other interconnection techniques available such as direct bonding. This paper, as a continuation of a review [M. Lozano, E. Cabruja, A. Collado, J. Santander, M. Ullan, Nucl. Instr. and Meth. A 473 (1-2) (2001) 95-101] published in 2001, presents an update of the different advanced bonding techniques available for manufacturing a hybrid active pixel detector.

  15. Estimation of the Performance of Multiple Active Neutron Interrogation Signatures for Detecting Shielded HEU

    Energy Technology Data Exchange (ETDEWEB)

    David L. Chichester; Scott J. Thompson; Scott M. Watson; James T. Johnson; Edward H. Seabury

    2012-10-01

    A comprehensive modeling study has been carried out to evaluate the utility of multiple active neutron interrogation signatures for detecting shielded highly enriched uranium (HEU). The modeling effort focused on varying HEU masses from 1 kg to 20 kg; varying types of shields including wood, steel, cement, polyethylene, and borated polyethylene; varying depths of the HEU in the shields, and varying engineered shields immediately surrounding the HEU including steel, tungsten, and cadmium. Neutron and gamma-ray signatures were the focus of the study and false negative detection probabilities versus measurement time were used as a performance metric. To facilitate comparisons among different approaches an automated method was developed to generate receiver operating characteristic (ROC) curves for different sets of model variables for multiple background count rate conditions. This paper summarizes results or the analysis, including laboratory benchmark comparisons between simulations and experiments. The important impact engineered shields can play towards degrading detectability and methods for mitigating this will be discussed.

  16. Routine determination of trace elements in fly ashes by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Szopa, Z.; Dybczynski, R.; Kulisa, K.; Sterlinski, S. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1994-12-31

    A method making possible routine determination of 24 trace elements in fly ashes by instrumental neutron activation analysis (INAA) is described. The method employs elemental standards, and the correction for neutron flux gradient in the irradiation package is performed with the aid of Au flux monitors. Important features of the method as: detectability, precision and accuracy are discussed in detail. Reliability of the method was demonstrated by the analysis of several certified reference materials (CRMs). Special attention was devoted to comparison of the experimentally obtained detection limits with those predicted by computer spectra simulation (CSS) method. The elemental enrichment factors calculated for Polish coal fly ash were compared with those typical for Chinese and Canadian fly ashes. (author). 21 refs, 7 figs.

  17. Studies on application of radiation and radioisotopes -Studies on application of neutron activation analysis-

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yong Sam; Jung, Yung Joo; Jung, Eui Sik; Lee, Sang Mee [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, Nak Bae [Korea Institute of Geology, Mining and Materials, Taejon (Korea, Republic of)

    1995-07-01

    To apply Neutron activation analysis to routine analysis of environmental samples utilizing the research reactor (TRIGA MK-III), improving effects of analytical sensitivity have been investigated using both of thermal and epithermal neutron irradiating technique. Identification and development of analytical procedure was carried out using three kinds of standard reference materials (urban particulate matter, coal fly ash, soil). In addition, the confidence of this method was established by participation in collaborative research for the training and apply of international credit of analytical procedure. Practical studies on air dust samples have also been carried out regionally and seasonally. For the investigation on emission source of special element, enrichment factor was calculated in urban and rural area. Besides, a suitable process of biological sample (pine needle) analyses has been established by carrying out identification of uncertainty using standard reference material. The concentration of elements in practical samples were also determined regionally and seasonally. 14 figs, 26 tabs, 67 refs. (Author).

  18. Elemental analysis of some Egyptian ores and industrial iron samples by neutron activation analysis

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Elemental analysis of iron ore samples and first industrial iron production prepared by the Egyptian Iron and Steel Company of Helwan near Cairo were determined by instrumental neutron activation analysis technique. Five samples from each kind were irradiated for a 48 hours at a thermal neutron flux of 4x1012 n/(cm2.s) in the first Egyptian research reactor ET-PP-1. Also the pneumatic irradiation rabbit system (PIRS) attached to the reactor in Inshass, was used to measure the elements of short-life time.The gamma-ray spectra were recorded by means of the hyper pure germanium detection system. The concentration percentage values of major, minor and trace elements are presented. The long and short lived isotopes were considered. A comparative study and a discussion on the elemental concentration values are given.

  19. Elemental analysis of two Egyptian iron ores and produced industrial iron samples by neutron activation analysis.

    Science.gov (United States)

    Sroo, A; Abdel-Basset, N; Abdel-Haleem, A S; Hassan, A M

    2001-03-01

    Elemental analysis of two iron ores and initial industrial iron production prepared by the Egyptian Iron and Steel Company of Helwan near Cairo were performed by the instrumental neutron activation analysis technique. Five samples of each type were irradiated for 48 h in a thermal neutron flux of 4 x 10(12) n/cm2 s in the first Egyptian research reactor ET-RR-1. Also, the Pneumatic Irradiation Rabbit System (PIRS), attached to the reactor ET-RR-1 in Inshass, was used to measure short-life elements. The gamma-ray spectra were obtained with a hyper pure germanium detection system. The concentration percentage values of major, minor and trace elements are presented. Implications of the elemental concentration values obtained are presented.

  20. Elemental analysis of two Egyptian iron ores and produced industrial iron samples by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sroor, A.; Abdel-Basset, N.; Abdel-Haleem, A.S.; Hassan, A.M

    2001-03-01

    Elemental analysis of two iron ores and initial industrial iron production prepared by the Egyptian Iron and Steel Company of Helwan near Cairo were performed by the instrumental neutron activation analysis technique. Five samples of each type were irradiated for 48 h in a thermal neutron flux of 4x10{sup 12} n/cm{sup 2} s in the first Egyptian research reactor ET-RR-1. Also, the Pneumatic Irradiation Rabbit System (PIRS), attached to the reactor ET-RR-1 in Inshass, was used to measure short-life elements. The {gamma}-ray spectra were obtained with a hyper pure germanium detection system. The concentration percentage values of major, minor and trace elements are presented. Implications of the elemental concentration values obtained are presented.

  1. Elemental analysis of some Egyptian ores and industrial iron samples by neutron activation analysis.

    Science.gov (United States)

    Srror, A; Abdel-Basset, N; Abdel-Haleem, A S; Hassan, A M

    2001-01-01

    Elemental analysis of iron ore samples and first industrial iron production prepared by the Egyptian Iron and Steel Company of Helwan near Cairo were determined by instrumental neutron activation analysis technique. Five samples from each kind were irradiated for a 48 hours at a thermal neutron flux of 4 x 10(12) n/(cm2.s) in the first Egyptian research reactor ET-RR-1. Also the Pneumatic irradiation Rabbit system (PIRS) attached to the reactor in Inshass, was used to measure the elements of short-life time. The gamma-ray spectra were recorded by means of the hyper pure germanium detection system. The concentration percentage values of major, minor and trace elements are presented. The long and short lived isotopes were considered. A comparative study and a discussion on the elemental concentration values are given.

  2. Sensor to detect endothelialization on an active coronary stent

    Directory of Open Access Journals (Sweden)

    Coffey Arthur C

    2010-11-01

    Full Text Available Abstract Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks.

  3. Développement d'un capteur CMOS intégré pour un futur dosimètre électronique personnel de neutrons

    OpenAIRE

    Zhang, Ying

    2012-01-01

    This thesis presents the development of CMOS sensors for a future neutron sensitive electronic individual dosemeter. Active dosemeters, exist but do not yet give results as satisfactory as passive devices, being however, mandatory for workers in addition to the passive dosimetry since 1995 (IEC 1323). The RaMsEs group in the laboratory IPHC is exploring a new compact device based on CMOS sensors for operational neutron dosimetry. In this thesis, a dedicated sensor, AlphaRad-2, with low noise ...

  4. Activity recognition with wearable sensors on loose clothing

    National Research Council Canada - National Science Library

    Brendan Michael; Matthew Howard

    2017-01-01

    .... However, wearable sensors suffer from motion artefacts introduced by the non-rigid attachment of sensors to the body, and the prevailing view is that it is necessary to eliminate these artefacts...

  5. A new active method for the measurement of slow-neutron fluence in modern radiotherapy treatment rooms

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, F; Iglesias, A [Departamento de Fisica de Particulas, Universidad de Santiago, 15782-Santiago (Spain); Doblado, F Sanchez [Hospital Universitario Virgen Macarena, Radiofisica and Departamento de Fisiologia Medica y Biofisica, Facultad de Medicina, Universidad de Sevilla (Spain)], E-mail: faustino.gomez@usc.es

    2010-02-21

    This work focuses on neutron monitoring at clinical linac facilities during high-energy modality radiotherapy treatments. Active in-room measurement of neutron fluence is a complex problem due to the pulsed nature of the fluence and the presence of high photon background, and only passive methods have been considered reliable until now. In this paper we present a new active method to perform real-time measurement of neutron production around a medical linac. The device readout is being investigated as an estimate of patient neutron dose exposure on each radiotherapy session. The new instrument was developed based on neutron interaction effects in microelectronic memory devices, in particular using neutron-sensitive SRAM devices. This paper is devoted to the description of the instrument and measurement techniques, presenting the results obtained together with their comparison and discussion. Measurements were performed in several standard clinical linac facilities, showing high reliability, being insensitive to the photon fluence and EM pulse present inside the radiotherapy room, and having detector readout statistical relative uncertainties of about 2% on measurement of neutron fluence produced by 1000 monitor units irradiation runs.

  6. Adhesive disbond detection using piezoelectric wafer active sensors

    Science.gov (United States)

    Roth, William; Giurgiutiu, Victor

    2015-04-01

    The aerospace industry continues to increase the use of adhesives for structural bonding due to the increased joint efficiency (reduced weight), even distribution of the load path and decreases in stress concentrations. However, the limited techniques for verifying the strength of adhesive bonds has reduced its use on primary structures and requires an intensive inspection schedule. This paper discusses a potential structural health monitoring (SHM) technique for the detection of disbonds through the in situ inspection of adhesive joints. This is achieved through the use of piezoelectric wafer active sensors (PWAS), thin unobtrusive sensors which are permanently bonded to the aircraft structure. The detection method discussed in this study is electromechanical impedance spectroscopy (EMIS), a local vibration method. This method detects disbonds from the change in the mechanical impedance of the structure surrounding the disbond. This paper will discuss how predictive modeling can provide valuable insight into the inspection method, and provide better results than empirical methods alone. The inspection scheme was evaluated using the finite element method, and the results were verified experimentally using a large aluminum test article, and included both pristine and disbond coupons.

  7. An investigation of the neutron flux in bone-fluorine phantoms comparing accelerator based in vivo neutron activation analysis and FLUKA simulation data

    Energy Technology Data Exchange (ETDEWEB)

    Mostafaei, F.; McNeill, F.E.; Chettle, D.R.; Matysiak, W.; Bhatia, C.; Prestwich, W.V.

    2015-01-01

    We have tested the Monte Carlo code FLUKA for its ability to assist in the development of a better system for the in vivo measurement of fluorine. We used it to create a neutron flux map of the inside of the in vivo neutron activation analysis irradiation cavity at the McMaster Accelerator Laboratory. The cavity is used in a system that has been developed for assessment of fluorine levels in the human hand. This study was undertaken to (i) assess the FLUKA code, (ii) find the optimal hand position inside the cavity and assess the effects on precision of a hand being in a non-optimal position and (iii) to determine the best location for our γ-ray detection system within the accelerator beam hall. Simulation estimates were performed using FLUKA. Experimental measurements of the neutron flux were performed using Mn wires. The activation of the wires was measured inside (1) an empty bottle, (2) a bottle containing water, (3) a bottle covered with cadmium and (4) a dry powder-based fluorine phantom. FLUKA was used to simulate the irradiation cavity, and used to estimate the neutron flux in different positions both inside, and external to, the cavity. The experimental results were found to be consistent with the Monte Carlo simulated neutron flux. Both experiment and simulation showed that there is an optimal position in the cavity, but that the effect on the thermal flux of a hand being in a non-optimal position is less than 20%, which will result in a less than 10% effect on the measurement precision. FLUKA appears to be a code that can be useful for modeling of this type of experimental system.

  8. A Micro-Fabricated Force Sensor Using an All Thin Film Piezoelectric Active Sensor

    Directory of Open Access Journals (Sweden)

    Junwoo Lee

    2014-11-01

    Full Text Available The ability to measure pressure and force is essential in biomedical applications such as minimally invasive surgery (MIS and palpation for detecting cancer cysts. Here, we report a force sensor for measuring a shear and normal force by combining an arrayed piezoelectric sensors layer with a precut glass top plate connected by four stress concentrating legs. We designed and fabricated a thin film piezoelectric force sensor and proposed an enhanced sensing tool to be used for analyzing gentle touches without the external voltage source used in FET sensors. Both the linear sensor response from 3 kPa to 30 kPa and the exact signal responses from the moving direction illustrate the strong feasibility of the described thin film miniaturized piezoelectric force sensor.

  9. Measurement and calculations of long-lived radionuclide activity forming in the fast neutron field in some ITER construction steels

    Energy Technology Data Exchange (ETDEWEB)

    Pohorecki, W., E-mail: poho@agh.edu.pl [AGH University of Science and Technology, Faculty of Energy and Fuels, Al. Mickiewicza 30, 30-059 Krakow (Poland); Jodłowski, P. [AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Al. Mickiewicza 30, 30-059 Krakow (Poland); Pytel, K.; Prokopowicz, R. [National Centre for Nuclear Research, ul. Sołtana 7, 05-400 Otwock-Świerk (Poland)

    2014-10-15

    Highlights: • Measurement and calculations of long-lived gamma-emitting radionuclide activity forming in the fission reactor fast neutron field were done, in some ITER construction steels. • The neutron flux density was measured by means of activation foil method and unfolding technique. • Activity calculations were done by means of FISPACT-II code using the activation libraries EAF-2010 and TALYS-2011. • The activity measurements were done by means of gamma-ray spectrometry. - Abstract: Measurement and calculations of long-lived gamma-emitting radionuclide activity forming in the fission reactor fast neutron field were done, for some ITER construction steels. The activation was conducted in fast neutron irradiation channel of the MARIA research fission reactor (Poland). The dimensions of steel samples were 10 mm × 10 mm × 1 mm and mass was approximately 0.8 g. The neutron flux density was measured by means of activation foil method and unfolding technique; fraction of neutrons above 1 keV was 95%. The activation lasted 242 h and cooling took 100 days; the mean neutron flux density was 2.9E12 n/(cm{sup 2} s) (neutrons above 500 keV are 53% of total) whereas total fluency 2.53E18 cm{sup −2}. The activity measurements were done by means of gamma-ray spectrometry. Activity calculations were done by means of FISPACT-II code using the activation libraries EAF-2010 and TENDL-2011 and experimentally determined neutron flux. Measured activity of long-lived gamma emitting radionuclides was, in average, about 6.3 MBq/g 100 days after activation; the dominant radionuclides were {sup 58}Co and {sup 54}Mn (about 81% and 14% of total activity respectively). The C/E ratio differs for particular radionuclides and is in the range 0.86–0.92 for {sup 51}Cr, 0.93–1.21 for {sup 54}Mn, 0.77–0.98 for {sup 57}Co, 0.91–1.21 for {sup 58}Co, 1.17–1.27 for {sup 59}Fe, and 1.75–2.44 for {sup 60}Co.

  10. Determination of uranium fission product interference factor for molybdenum quantification by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro Junior, Ibere S.; Saiki, Mitiko; Genezini, Frederico A.; Zahn, Guilherme S., E-mail: ibere@usp.br, E-mail: mitiko@ipen.br, E-mail: fredzini@ipen.br, E-mail: gzahn@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Instrumental Neutron Activation Analysis (INAA) is a technique that provides high precision and accuracy results for the concentration determinations of several elements in different kinds of matrices. However, if the sample contains high uranium concentration in their composition, INAA can provide inaccurate results due to uranium fission product interferences. The molybdenum is one of these elements that suffers interference by uranium fission product, because the {sup 99}Mo radioisotope formed by {sup 98}Mo neutron capture, used in INAA, is the same that formed in the uranium fission. This kind of interference can be solved by separation of uranium before irradiation or by determining the uranium interference factor to the radioisotope of interest and applying the correction. The present study aims at the following: (1) determination of the Mo interference factor (F{sub Exp}{sup Mo}) due to the uranium fission product {sup 99}Mo by irradiating standards of Mo and U with known masses of these elements (experimental interference factor); (2) determination of the theoretical F{sub Th}{sup Mo}, in this case it was necessary to determine the epithermal to thermal neutron flux ratio and use the reported nuclear parameters; (3) comparison of the results of the interference factor obtained with values reported in the literature. The interference factor for Mo analysis was obtained in a position 14b shelf 3 of the IEA-R1 nuclear research reactor. (author)

  11. A prompt gamma neutron activation analysis facility using a diffracted beam

    Science.gov (United States)

    Harling, Otto K.; Chabeuf, Jean-Michel; Lambert, Frédérique; Yasuda, Gopika

    1993-12-01

    A prompt gamma neutron activation analysis facility has been constructed at the MIT Research Reactor using a diffracted beam from a multilayered graphite monochromator. A beam of 0.0143 eV neutrons of intensity 6 × 10 6{n}/{cm 2}s is available at the sample position. Backgrounds are low due to the use of the diffracted beam and are further improved by a sapphire crystal in the beam line. This design allowed the Ge detecting crystal to be placed close to the sample position, 4 cm, with a resultant high detection efficiency. The sensitivity of the facility is reported for several representative pure elements. The major impetus for the construction of this facility was the need for accurate analyses of 10B in biological samples for neutron capture therapy research. Detailed results for this type of analysis are provided. The sensitivity of this diffracted beam facility currently exceeds that of two representative direct beam facilities using reactors of twice the power of the MITR-II. Possible major improvements in sensitivity, more than an order of magnitude, and in background levels are outlined for future development.

  12. SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Thatcher, T; Madsen, S; Sudowe, R [University of Nevada, Las Vegas, Las Vegas, NV (United States); Meigooni, A Soleimani [University of Nevada, Las Vegas, Las Vegas, NV (United States); Comprehensive Cancer Center of Nevada, Las Vegas, Nevada (United States)

    2015-06-15

    Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cm solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.

  13. Active temperature compensation design of sensor with fiber gratings

    Institute of Scientific and Technical Information of China (English)

    Xingfa Dong(董兴法); Yonglin Huang(黄勇林); Li Jiang(姜莉); Guiyun Kai(开桂云); Xiaoyi Dong(董孝义)

    2004-01-01

    A technique for compensation of temperature effects in fiber grating sensors is reported. For strain sensors and other sensors related to strain such as electromagnetic sensors, a novel structure is designed, which uses two fiber Bragg gratings (FBGs) as strain differential sensor and has temperature effects cancelled. Using this technique, the stress sensitivity has been amplified and gets up to 0.226 nm/N, the total variation in wavelength difference within the range of 3-45 ℃ is 0.03 nm, 1/14 of the uncompensated FBG.The structure can be used in the temperature-insensitive static strain measurement and minor-vibration measurement.

  14. Soil Moisture Estimation Across Scales with Mobile Sensors for Cosmic-Ray Neutrons from the Ground and Air

    Science.gov (United States)

    Schrön, Martin; Köhler, Mandy; Bannehr, Lutz; Köhli, Markus; Fersch, Benjamin; Rebmann, Corinna; Mai, Juliane; Cuntz, Matthias; Kögler, Simon; Schröter, Ingmar; Wollschläger, Ute; Oswald, Sascha; Dietrich, Peter; Zacharias, Steffen

    2016-04-01

    Soil moisture is a key variable for environmental sciences, but its determination at various scales and depths is still an open challenge. Cosmic-ray neutron sensing has become a well accepted and unique method to monitor an effective soil water content, covering tens of hectares in area and tens of centimeters in depth. The technology is famous for its low maintanance, non-invasiveness, continous measurement, and most importantly its large footprint and penetration depth. Beeing more representative than point data, and finer resolved plus deeper penetrating than remote-sensing products, cosmic-ray neutron derived soil moisture products provide unrivaled advantage for agriculture, regional hydrologic and land surface models. The method takes advantage of omnipresent neutrons which are extraordinarily sensitive to hydrogen in soil, plants, snow and air. Unwanted hydrogen sources in the footprint can be excluded by local calibration to extract the pure soil water information. However, this procedure is not feasible for mobile measurements, where neutron detectors are mounted on a car to do catchment-scale surveys. As a solution to that problem, we suggest strategies to correct spatial neutron data with the help of available spatial data of soil type, landuse and vegetation. We further present results of mobile rover campaigns at various scales and conditions, covering small sites from 0.2 km2 to catchments of 100 km2 area, and complex terrain from agricultural fields, urban areas, forests, to snowy alpine sites. As the rover is limited to accessible roads, we further investigated the applicability of airborne measurements. First tests with a gyrocopter at 150 to 200m heights proofed the concept of airborne neutron detection for environmental sciences. Moreover, neutron transport simulations confirm an improved areal coverage during these campaigns. Mobile neutron measurements at the ground or air are a promising tool for the detection of water sources across many

  15. SHM of wind turbine blades using piezoelectric active-sensors

    Energy Technology Data Exchange (ETDEWEB)

    Park, Gyuhae [Los Alamos National Laboratory; Taylor, Stuart G [Los Alamos National Laboratory; Farinholt, Kevin M [Los Alamos National Laboratory; Farrar, Charles R [Los Alamos National Laboratory

    2010-01-01

    This paper presents a variety of structural health monitoring (SHM) techniques, based on the use of piezoelectric active-sensors, used to determine the structural integrity of wind turbine blades. Specifically, Lamb wave propagations, frequency response functions, and time series based methods are utilized to estimate the condition of wind turbine blades. For experiments, a 1m section of a 9m CX100 blade is used. Overall, these three methods yielded a sufficient damage detection capability to warrant further investigation into field deployment. A full-scale fatigue test of a CX-100 wind turbine blade is also conducted. This paper summarizes considerations needed to design such SHM systems, experimental procedures and results, and practical implementation issues that can be used as guidelines for future investigations.

  16. A Single-Transistor Active Pixel CMOS Image Sensor Architecture

    Institute of Scientific and Technical Information of China (English)

    ZHANG Guo-An; ZHANG Dong-Wei; HE Jin; SU Yan-Mei; WANG Cheng; CHEN Qin; LIANG Hai-Lang; YE Yun

    2012-01-01

    A single-transistor CMOS active pixel image sensor (1T CMOS APS) architecture is proposed,By switching the photosensing pinned diode,resetting and selecting can be achieved by diode pull-up and capacitive coupling pull-down of the source follower. Thus,the reset and selected transistors can be removed. In addition,the reset and selected signal lines can be shared to reduce the metal signal line,leading to a very high fill factor.The pixel design and operation principles are discussed in detail.The functionality of the proposed 1 T CMOS APS architecture has been experimentally verified using a fabricated chip in a standard 0.35 μm CMOS AMIS technology.

  17. Analysis of medicinal plant extracts by neutron activation method; Analise de extratos de plantas medicinais pelo metodo de ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Vaz, Sandra Muntz

    1995-12-31

    This dissertation has presented the results from analysis of medicinal plant extracts using neutron activation method. Instrumental neutron activation analysis was applied to the determination of the elements Al, Br, Ca, Ce, Cl, Cr, Cs, Fe, K, La, Mg, Mn, Na, Rb, Sb, Sc and Zn in medicinal extracts obtained from Achyrolcline satureoides DC, Casearia sylvestris, Centella asiatica, Citrus aurantium L., Solano lycocarpum, Solidago microglossa, Stryphnondedron barbatiman and Zingiber officinale R. plants. The elements Hg and Se were determined using radiochemical separation by means of retention of Se in HMD inorganic exchanger and solvent extraction of Hg by bismuth diethyl-dithiocarbamate solution. Precision and accuracy of the results have been evaluated by analysing reference materials. The therapeutic action of some elements found in plant extracts analyzed was briefly discussed 70 refs., 13 figs., 15 tabs

  18. Development of Monte Carlo code for coincidence prompt gamma-ray neutron activation analysis

    Science.gov (United States)

    Han, Xiaogang

    Prompt Gamma-Ray Neutron Activation Analysis (PGNAA) offers a non-destructive, relatively rapid on-line method for determination of elemental composition of bulk and other samples. However, PGNAA has an inherently large background. These backgrounds are primarily due to the presence of the neutron excitation source. It also includes neutron activation of the detector and the prompt gamma rays from the structure materials of PGNAA devices. These large backgrounds limit the sensitivity and accuracy of PGNAA. Since most of the prompt gamma rays from the same element are emitted in coincidence, a possible approach for further improvement is to change the traditional PGNAA measurement technique and introduce the gamma-gamma coincidence technique. It is well known that the coincidence techniques can eliminate most of the interference backgrounds and improve the signal-to-noise ratio. A new Monte Carlo code, CEARCPG has been developed at CEAR to simulate gamma-gamma coincidence spectra in PGNAA experiment. Compared to the other existing Monte Carlo code CEARPGA I and CEARPGA II, a new algorithm of sampling the prompt gamma rays produced from neutron capture reaction and neutron inelastic scattering reaction, is developed in this work. All the prompt gamma rays are taken into account by using this new algorithm. Before this work, the commonly used method is to interpolate the prompt gamma rays from the pre-calculated gamma-ray table. This technique works fine for the single spectrum. However it limits the capability to simulate the coincidence spectrum. The new algorithm samples the prompt gamma rays from the nucleus excitation scheme. The primary nuclear data library used to sample the prompt gamma rays comes from ENSDF library. Three cases are simulated and the simulated results are benchmarked with experiments. The first case is the prototype for ETI PGNAA application. This case is designed to check the capability of CEARCPG for single spectrum simulation. The second

  19. Neutron activation analysis of medullar and cortical bone tissues from animals; Analise por ativacao com neutrons de tecidos osseos medular e cortical de animais

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Marcelo Kazuo; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Supervisao de Radioquimica

    2000-07-01

    In this work, neutron activation analysis was applied in the determination of the elements Ba, Br, Ca, Cl, Cr, Fe, K, Mg, Mn, Na, P, Rb, Sb, Sc, Sr and Zn present in animal bone tissues. The obtained results indicated a significant difference between the elemental concentrations present in medullar and cortical tissues. The results obtained for bone tissues from distinct animal species were also different. (author)

  20. New thermal neutron prompt {gamma}-ray activation analysis instrument at the National Institute of Standards and Technology Center for Neutron Research

    Energy Technology Data Exchange (ETDEWEB)

    Mackey, E.A. E-mail: lmackey@nist.gov; Anderson, D.L.; Liposky, P.J.; Lindstrom, R.M.; Chen-Mayer, H.; Lamaze, G.P

    2004-11-01

    A new thermal neutron prompt {gamma}-ray activation analysis (PGAA) instrument was designed and built to replace the original PGAA system at the NIST Center for Neutron Research. By placing a sapphire filter in the neutron beam shutter assembly, the fast neutron fluence rate was reduced by a factor of 5 and low-energy (50-200 keV) {gamma}-ray intensities were reduced by factors of 5-10. The thermal neutron fluence rate was reduced by only a factor of 1.13. A new external beam tube, sample chamber, beam stop, and support structure were built and a new detection system installed. The new beam tube is made of two cylindrical aluminum sections lined with a lithiated polymer. Both sections are kept under vacuum to reduce the number of neutrons scattered by air into the beam tube walls. The sample chamber is also fabricated from aluminum and lined with lithiated polymer, and may be evacuated to minimize the number of neutrons scattered and absorbed by air. The beam tube and sample chamber assembly is suspended from the aluminum support structure. The detection system consists of a 40% efficient (relative) germanium detector (resolution 2.0 at 1332.5 keV) and a bismuth germanate Compton suppressor. The detection system is shielded by lead, surrounded by borated and lithiated polyethylene, and placed on a table attached to the support structure. The new, more compact beam stop is welded to the support structure. Capture {gamma}-ray photopeaks from H, B, C, N, Na, Al, Fe, Ge, I and Pb in the background spectrum were either of lower intensity or eliminated with the new PGAA instrument. The more efficient detection system, positioned closer to the sample, yielded element sensitivity increases of 5-50%. Limits of detection have been greatly reduced compared with those of the original instrument due to reduced Compton and scattered {gamma}-ray backgrounds (especially in the low-energy region), increased sensitivities, and reduction of background {gamma}-ray photopeak

  1. Au Foil Activation Measurement and Simulation of the Concrete Neutron Shielding Ability for the Proposed New SANRAD Facility

    Science.gov (United States)

    Radebe, M. J.; Korochinsky, S.; Strydom, W. J.; De Beer, F. C.

    The purpose of this study was to measure the effective neutron shielding characteristics of the new shielding material designed and manufactured to be used for the construction of the new SANRAD facility at Necsa, South Africa, through Au foil activation as well as MCNP simulations. The shielding capability of the high density shielding material was investigated in the worst case region (the neutron beam axis) of the experimental chamber for two operational modes. The everyday operational mode includes the 15 cm thick poly crystalline Bismuth filter at room temperature (assumed) to filter gamma-rays and some neutron spectrum energies. The second mode, dynamic imaging, will be conducted without the Bi-filter. The objective was achieved through a foil activation measurement at the current SANRAD facility and MCNP calculations. Several Au foilswere imbedded at different thicknesses(two at each position) of shielding material up to 80 cm thick to track the attenuation of the neutron beam over distance within the shielding material. The neutron flux and subsequently the associated dose rates were calculated from the activation levels of the Au foils. The concrete shielding material was found to provide adequate shielding for all energies of neutrons emerging from beam port no-2 of the SAFARI-1 research reactorwithin a thickness of 40 cm of concrete.

  2. Application of neural networks for unfolding neutron spectra measured by means of Bonner spheres and activation foils

    CERN Document Server

    Braga, C C

    2001-01-01

    A neural network structure has been used for unfolding neutron spectra measured by means of a Bonner Sphere Spectrometer set and a foil activation set using several neutron induced reactions. The present work used the SNNS (Stuttgart Neural Network Simulator) as the interface for designing, training and validation of the Multilayer Perceptron network. The back-propagation algorithm was applied. The Bonner Sphere set chosen has been calibrated at the National Physical Laboratory, United Kingdom, and uses gold activation foils as thermal neutron detectors. The neutron energy covered by the response functions goes from 0.0001 eV to 14 MeV. The foil activation set chosen has been irradiated at the IEA-R1 research reactor and measured at the Nuclear Metrology Laboratory of IPEN-CNEN/SP. Two types of neutron spectra were numerically investigated: monoenergetic and continuous The unfolded spectra were compared to a conventional method using code SAND-II as part of the neutron dosimetry system SAIPS. Good results wer...

  3. Recognizing Multi-user Activities using Wearable Sensors in a Smart Home

    DEFF Research Database (Denmark)

    Wang, Liang; Gu, Tao; Tao, Xianping

    2010-01-01

    The advances of wearable sensors and wireless networks oer many opportunities to recognize human activities from sensor readings in pervasive computing. Existing work so far focuses mainly on recognizing activities of a single user in a home environment. However, there are typically multiple...... inhabitants in a real home and they often perform activities together. In this paper, we investigate the problem of recognizing multi-user activities using wearable sensors in a home setting. We develop a multi-modal, wearable sensor platform to collect sensor data for multiple users, and study two temporal...... probabilistic models—Coupled Hidden Markov Model (CHMM) and Factorial Conditional Random Field (FCRF)—to model interacting processes in a sensor-based, multi-user scenario. We conduct a real-world trace collection done by two subjects over two weeks, and evaluate these two models through our experimental...

  4. Neutron-activation analysis of hot particles from the vicinity of the Chernobyl Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Lyul`, A.Yu.; Kolesov, G.M.; Cherkezyan, V.O. [V.I. Vernadskii Institute of Geochemistry and Analytical Chemistry, Moscow (Russian Federation)

    1994-04-10

    A considerable portion of the radioactive contamination of the surface layers of soil after the accident at the Chernobyl Nuclear Power Plant was caused by hot particles or aggregates with a diameter of several tens microns and a specific activity >n{center_dot}10{sup {minus}11} Ci. They consist of primary particles of the dispersed material of the nuclear fuel and secondary particles formed as a result of the interaction of the fuel and uranium fission products with the structural materials of the reactor and the destroyed active zone. The radionuclide composition of the hot particles characterizes the nuclear fuel used and the temperature conditions in the reactor during the first weeks after the accident and their chemical composition reflects the conditions and processes leading to their formation, which must be known in order; to ascertain the mechanism of the formation of the radioactive emission from the reactor and to evaluate the degree of ecological danger posed by the particles. All this promotes the urgency and importance of studying the radiation-chemical characteristics of such hot particles. Their small sizes and masses impose definite restrictions; on the investigative methods used, which must be highly sensitive and must offer the possibility of performing a nondestructive analysis. One such method is neutron-activation analysis. The purpose of the present investigation was to apply instrumental neutron-activation analysis to the simultaneous determination of the elemental composition of hot particles and establishment of the isotopic composition of the uranium in them.

  5. Fused performance of passive thermal and active polarimetric EO demining sensor

    Science.gov (United States)

    Liao, Wen-Jiao; Baertlein, Brian A.

    2002-08-01

    The potential for performance improvements through sensor fusion is explored for two electro-optical (EO) imaging sensors: a passive thermal IR camera and an active polarimetric system. Tests of decision-level fusion using a small data set (roughly 60 mine signatures) suggest that a significant performance improvement can be obtained by using an AND fusion approach. The source of this improvement derives from correlation among the sensors. Specifically, the sensors exhibit a strong positive correlation when a mine is present, and a negligible correlation when viewing clutter. The observed improvement is independent of the local ground clutter, but it depends strongly on the decision thresholds used for the individual sensors.

  6. L'analyse par activation de neutrons de réacteur

    Science.gov (United States)

    Meyer, G.

    2003-02-01

    Quand les neutrons traversent la matière, certains sont transmis sans interaction, les autres interagissent avec le milieu traversé par diffusion et par absorption. Ce phénomène d'absorption est utilisé pour se protéger des neutrons, mais aussi pour les détecter; il peut également être utilisé pour identifier les noyaux “absorbants" et ainsi analyser le milieu traversé. En effet par différentes réactions nucléaires (n,γ), (n,p), (n,α), (n,fission), on obtient des noyaux résiduels qui sont souvent radioactifs; on dit que l'échantillon est “activé". Si l'on connaît le rendement d'activation et donc le pourcentage de noyaux ainsi “transmutés", les mesures de radioactivité induite vont permettre de déterminer la composition de l'échantillon irradié. Cette méthode dite d'analyse par activation neutronique est pratiquée depuis la découverte du neutron. Elle a permis grâce à sa sélectivité et à sa sensibilité d'avoir accès au domaine des traces et des ultra-traces dans des champs d'application très divers comme la métallurgie, l'archéologie, la biologie, la géochimie etc...

  7. Vector disparity sensor with vergence control for active vision systems.

    Science.gov (United States)

    Barranco, Francisco; Diaz, Javier; Gibaldi, Agostino; Sabatini, Silvio P; Ros, Eduardo

    2012-01-01

    This paper presents an architecture for computing vector disparity for active vision systems as used on robotics applications. The control of the vergence angle of a binocular system allows us to efficiently explore dynamic environments, but requires a generalization of the disparity computation with respect to a static camera setup, where the disparity is strictly 1-D after the image rectification. The interaction between vision and motor control allows us to develop an active sensor that achieves high accuracy of the disparity computation around the fixation point, and fast reaction time for the vergence control. In this contribution, we address the development of a real-time architecture for vector disparity computation using an FPGA device. We implement the disparity unit and the control module for vergence, version, and tilt to determine the fixation point. In addition, two on-chip different alternatives for the vector disparity engines are discussed based on the luminance (gradient-based) and phase information of the binocular images. The multiscale versions of these engines are able to estimate the vector disparity up to 32 fps on VGA resolution images with very good accuracy as shown using benchmark sequences with known ground-truth. The performances in terms of frame-rate, resource utilization, and accuracy of the presented approaches are discussed. On the basis of these results, our study indicates that the gradient-based approach leads to the best trade-off choice for the integration with the active vision system.

  8. Vector Disparity Sensor with Vergence Control for Active Vision Systems

    Directory of Open Access Journals (Sweden)

    Eduardo Ros

    2012-02-01

    Full Text Available This paper presents an architecture for computing vector disparity for active vision systems as used on robotics applications. The control of the vergence angle of a binocular system allows us to efficiently explore dynamic environments, but requires a generalization of the disparity computation with respect to a static camera setup, where the disparity is strictly 1-D after the image rectification. The interaction between vision and motor control allows us to develop an active sensor that achieves high accuracy of the disparity computation around the fixation point, and fast reaction time for the vergence control. In this contribution, we address the development of a real-time architecture for vector disparity computation using an FPGA device. We implement the disparity unit and the control module for vergence, version, and tilt to determine the fixation point. In addition, two on-chip different alternatives for the vector disparity engines are discussed based on the luminance (gradient-based and phase information of the binocular images. The multiscale versions of these engines are able to estimate the vector disparity up to 32 fps on VGA resolution images with very good accuracy as shown using benchmark sequences with known ground-truth. The performances in terms of frame-rate, resource utilization, and accuracy of the presented approaches are discussed. On the basis of these results, our study indicates that the gradient-based approach leads to the best trade-off choice for the integration with the active vision system.

  9. Proton currents constrain structural models of voltage sensor activation

    Science.gov (United States)

    Randolph, Aaron L; Mokrab, Younes; Bennett, Ashley L; Sansom, Mark SP; Ramsey, Ian Scott

    2016-01-01

    The Hv1 proton channel is evidently unique among voltage sensor domain proteins in mediating an intrinsic ‘aqueous’ H+ conductance (GAQ). Mutation of a highly conserved ‘gating charge’ residue in the S4 helix (R1H) confers a resting-state H+ ‘shuttle’ conductance (GSH) in VGCs and Ci VSP, and we now report that R1H is sufficient to reconstitute GSH in Hv1 without abrogating GAQ. Second-site mutations in S3 (D185A/H) and S4 (N4R) experimentally separate GSH and GAQ gating, which report thermodynamically distinct initial and final steps, respectively, in the Hv1 activation pathway. The effects of Hv1 mutations on GSH and GAQ are used to constrain the positions of key side chains in resting- and activated-state VS model structures, providing new insights into the structural basis of VS activation and H+ transfer mechanisms in Hv1. DOI: http://dx.doi.org/10.7554/eLife.18017.001 PMID:27572256

  10. Noise Parameters of CW Radar Sensors Used in Active Defense Systems

    OpenAIRE

    2012-01-01

    Active defense represents an innovative way of protecting military vehicles. It is based on the employment of a set of radar sensors which detect an approaching threat missile and activate a suitable counter-measure. Since the radar sensors are supposed to detect flying missiles very fast and, at the same time, distinguish them from stationary or slow-moving objects, CW Doppler radar sensors can be employed with a benefit. The submitted article deals with a complex noise analysis of this type...

  11. Thin n-in-p planar pixel sensors and active edge sensors for the ATLAS upgrade at HL-LHC

    Science.gov (United States)

    Terzo, S.; Macchiolo, A.; Nisius, R.; Paschen, B.

    2014-12-01

    Silicon pixel modules employing n-in-p planar sensors with an active thickness of 200 μm, produced at CiS, and 100-200 μm thin active/slim edge sensor devices, produced at VTT in Finland have been interconnected to ATLAS FE-I3 and FE-I4 read-out chips. The thin sensors are designed for high energy physics collider experiments to ensure radiation hardness at high fluences. Moreover, the active edge technology of the VTT production maximizes the sensitive region of the assembly, allowing for a reduced overlap of the modules in the pixel layer close to the beam pipe. The CiS production includes also four chip sensors according to the module geometry planned for the outer layers of the upgraded ATLAS pixel detector to be operated at the HL-LHC. The modules have been characterized using radioactive sources in the laboratory and with high precision measurements at beam tests to investigate the hit efficiency and charge collection properties at different bias voltages and particle incidence angles. The performance of the different sensor thicknesses and edge designs are compared before and after irradiation up to a fluence of 1.4 × 1016 neq/cm2.

  12. Instrumental neutron activities analysis of Marrubium vulgare L., a valuable medicinal herb

    Energy Technology Data Exchange (ETDEWEB)

    Nedjimi, Bouzid [Djelfa Univ. (Algeria). Lab. of Exploration and Valorization of Steppe Ecosystem; Beladel, Brahim [Djelfa Univ. (Algeria). Dept. of Physics

    2016-08-01

    Twenty two chemical elements were identified by Instrumental neutron activation analysis in Marrubium vulgare (Lamiaceae) a traditional medicine plant, used indigenously in Mediterranean basin to cure several diseases. The precision of the results was assessed by analyzing the certified reference material GBW 07605 (GSV-4) Tea leaves. Results showed that K was the dominant chemical element in studied plant (4.40%). The Ca and Fe mass fractions were also relatively high. However potential toxic elements in this Lamiaceae plant were within the safety limits suggested by WHO/FAO.

  13. Neutron activation analysis of low-level element contents in silicon wafers

    Energy Technology Data Exchange (ETDEWEB)

    Goerner, W. [Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Berger, A. [Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Niese, S. [Verein fuer Kernverfahrenstechnik und Analytik Rossendorf e.V. (VKTA), Dresden (Germany); Koehler, M. [Verein fuer Kernverfahrenstechnik und Analytik Rossendorf e.V. (VKTA), Dresden (Germany); Matthes, M. [Verein fuer Kernverfahrenstechnik und Analytik Rossendorf e.V. (VKTA), Dresden (Germany); Gawlik, D. [Hahn-Meitner-Institut, Berlin (Germany)

    1997-03-01

    Semiconductor silicon is among the purest materials having ever been produced by modern technology. Thus, it is quite suitable as a primary reference material validating the correctness and the detection capabilities of developed analytical methods. Among them neutron activation analysis plays a competitive role. The U.S. National Institute of Science and Technology (NIST) has initiated and carried out an interlaboratory comparison in order to study the spread of analytical results worldwide evolved by several laboratories dealing with specimens of extreme purity. The outcome of the experiment was intended to review the capabilities of NAA as well as to differentiate between bulk and surface contamination. (orig./DG)

  14. Neutron activation analysis of chemical impurities in manipulated samples of omeprazole

    Energy Technology Data Exchange (ETDEWEB)

    Sepe, Fernanda Peixoto; Leal, Alexandre Soares; Gomes, Tatiana Cristina Bomfim; Menezes, Maria Angela de Barros Correia; Silva, Maria Aparecida, E-mail: asleal@cdtn.br [Nuclear Technology Development Centre/Brazilian Commission for Nuclear Energy (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    In this work, samples of Omeprazole (C{sub 17}H{sub 19}N{sub 3}O{sub 3}S), a largely used drug in the treatment of dyspepsia and peptic ulcer, were acquired from five different pharmacies of manipulation - or retail pharmacies which prepare personalized drugs under medical recommendation - in Belo Horizonte/Brazil and investigated using the k{sub 0} - Neutron Activation Analysis (NAA). The preliminary results showed the presence of elements not foreseen in the original formula. It confirms the potential risk offered by medicines without suitable inspection. (author)

  15. Optimal design of measurement network for neutronic activity field reconstruction by data assimilation

    Energy Technology Data Exchange (ETDEWEB)

    Bouriquet, Bertrand, E-mail: bertrand.bouriquet@cerfacs.fr [Sciences de l' Univers au CERFACS, URA CERFACS/CNRS No 1875, 42 avenue Gaspard Coriolis, F-31057 Toulouse Cedex 01 (France); Argaud, Jean-Philippe; Cugnart, Romain [Electricite de France, 1 avenue du General de Gaulle, F-92141 Clamart Cedex (France)

    2012-02-01

    An optimal reconstruction of the neutronic activity field can be determined for a nuclear reactor core using a data assimilation framework to merge information from models and measurements. In this paper, we focus on solving the inverse problem of determining an optimal repartition of the measuring instruments within the core, to get the best possible results from the data assimilation reconstruction procedure. The position optimisation is realised using a Simulated Annealing algorithm, based on the Metropolis-Hastings proposition. Moreover, algebraic improvements of data assimilation have been developed, optimising their computational performance, and are presented here.

  16. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used.

  17. Quantitative radiological characterization of waste. Integration of gamma spectrometry and passive/active neutron assay

    Energy Technology Data Exchange (ETDEWEB)

    Simone, Gianluca; Mauro, Egidio; Gagliardi, Filippo; Gorello, Edoardo [Nucleco S.p.A., Rome (Italy)

    2016-06-15

    The radiological characterization of drums through Non-Destructive Assay (NDA) techniques commonly relies on gamma spectrometry. This paper introduces the procedure developed in Nucleco for the NDA radiological characterization of drums when the presence of Special Nuclear Material (SNM) is expected/observed. The procedure is based on the integration of a gamma spectrometry in SGS mode (Segmented Gamma Scanner) and a passive/active neutron assay. The application of this procedure is discussed on a real case of drums. The extension of the integration procedure to other gamma spectrometry systems is also discussed.

  18. Chemical characterization of tin-lead glazed ceramics from Aragon (Spain) by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Inanez, J.G. [Smithsonian Institution, Suitland, MD (United States). Museum Conservation Inst.; Barcelona Univ. (Spain). Facultat de Geografia i Historia; Speakman, R.J. [Smithsonian Institution, Suitland, MD (United States). Museum Conservation Inst.; Buxeda i Garrigos, J. [Barcelona Univ. (Spain). Facultat de Geografia i Historia; Glascock, M.D. [Missouri Univ., Columbia, MO (United States). Research Reactor Center

    2010-07-01

    Majolica pottery was the most characteristic tableware produced in Spain during the Medieval and Renaissance periods. A study of the three main production centers in the historical region of Aragon during Middle Ages and Renaissance was conducted on a set of 71 samples. The samples were analyzed by instrumental neutron activation analysis (INAA), and the resulting data were interpreted using an array of multivariate statistical procedures. Our results show a clear discrimination among different production centers allowing a reliable provenance attribution of ceramic sherds from the Aragonese workshops. (orig.)

  19. Multi-element determination in medicinal Juniper tree (Juniperus phoenicea by instrumental neutron activation analysis

    Directory of Open Access Journals (Sweden)

    Bouzid Nedjimi

    2015-04-01

    Full Text Available Red Juniper (Juniperus phoenicea, a local medicinal tree was collected and analyzed for 18 essential, non-essential and toxic elements using instrumental neutron activation analysis (INAA. The GBW 07605 (GSV-4 standard reference material was analyzed simultaneously with the plant samples, the results shown a good recovery and reproducibility of the method. Ca, K and Fe have been detected in good levels in this plant clarifying their possible contribution to curative properties. The data obtained in the present work will be helpful in the synthesis of new synthetic drugs which can be used for medicinal purpose.

  20. Concentration of 17 Elements in Subcellular Fractions of Beef Heart Tissue Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P.O.

    1964-12-15

    Subcellular fractions of beef heart tissue are investigated, by means of neutron activation analysis, with respect to their concentration of 17 different elements. A recently developed ion-exchange technique combined with gamma spectrometry is used. The homogeneity of the subcellular fractions is examined electron microscopically. The following elements are determined: As, Ba, Br, Cas Co, Cs, Cu, Fe, Hg, La, Mo, P, Rb, Se, Sm, W and Zn. The determination of Ag, Au, Cd, Ce, Cr, Sb and Sc is omitted, in view of contamination. Reproducible and characteristic patterns of distribution are obtained for all elements studied.

  1. Performance of neutron activation analysis in the evaluation of bismuth iodide purification methodology

    Energy Technology Data Exchange (ETDEWEB)

    Armelin, Maria Jose A.; Ferraz, Caue de Mello; Hamada, Margarida M., E-mail: marmelin@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica

    2015-07-01

    Bismuth tri-iodide (BrI{sub 3}) is an attractive material for using as a semiconductor. In this paper, BiI{sub 3} crystals have been grown by the vertical Bridgman technique using commercially available powder. The impurities were evaluated by instrumental neutron activation analysis (INAA). The results show that INAA is an analytical method appropriate for monitoring the impurities of: Ag, As, Br, Cr, K, Mo, Na and Sb in the various stages of the BiI{sub 3} purification methodology. (author)

  2. Integral test on activation cross section of tag gas nuclides using fast neutron spectrum fields

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Takafumi; Suzuki, Soju [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-03-01

    Activation cross sections of tag gas nuclides, which will be used for the failed fuel detection and location in FBR plants, were evaluated by the irradiation tests in the fast neutron spectrum fields in JOYO and YAYOI. The comparison of their measured radioactivities and the calculated values using the JENDL-3.2 cross section set showed that the C/E values ranged from 0.8 to 2.8 for the calibration tests in YAYOI and that the present accuracies of these cross sections were confirmed. (author)

  3. Neutron capture cross-section of fission products in the European activation file EAF-3

    Energy Technology Data Exchange (ETDEWEB)

    Kopecky, J.; Delfini, M.G.; Kamp, H.A.J. van der; Gruppelaar, H.; Nierop, D. (Netherlands Energy Research Foundation (ECN), Petten (Netherlands))

    1992-05-01

    This paper contains a description of the work performed to extend and revise the neutron capture data in the European Activation File (EAF-3) with emphasis on nuclides in the fission-product mass range. The starter was the EAF-1 data file from 1989. The present version, EAF/NG-3, contains (n,[gamma]) excitation functions for all nuclides (729 targets) with half-lives exceeding 1/2 day in the mass range from H-1 to Cm-248. The data file is equipped with a preliminary uncertainty file, that will be improved in the near future. (author). 19 refs.; 5 figs.; 3 tabs.

  4. Neutron activation analysis and Mossbauer spectroscopy research on coloring mechanism of Chinese Ru porcelain

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The characteristic spectrum and its main wavelength of Ru porcelain glaze are measured by color difference instrument to determine the relations between glaze color and its main wavelength. The content of the 30 coloring elements in Ru porcelain is determined by neutron activation analysis (NAA), which showed that iron is the major coloring element. M?ssbauer spectroscopy analysis shows that the iron element in the glaze exists in the form of structural iron (Fe2+, Fe3+). The quantitative relationship between the main wavelength of glaze in various colors and the relative content of structural iron (Fe2+/Fe3+) is determined. Thus the coloring mechanism of Ru porcelain is investigated entirely.

  5. Solid electrolyte gas sensors based on cyclic voltammetry with one active electrode

    Energy Technology Data Exchange (ETDEWEB)

    Jasinski, G; Jasinski, P, E-mail: gregor@biomed.eti.pg.gda.pl [Gdansk University of Technology, Faculty of Electronics, Telecommunication and Informatics, Narutowicza 11/12, 80-233 Gdansk (Poland)

    2011-10-29

    Solid state gas sensors are cost effective, small, rugged and reliable. Typically electrochemical solid state sensors operate in either potentiometric or amperometric mode. However, a lack of selectivity is sometimes a shortcoming of such sensors. It seems that improvements of selectivity can be obtained in case of the electrocatalytic sensors, which operate in cyclic voltammetry mode. Their working principle is based on acquisition of an electric current, while voltage ramp is applied to the sensor. The current-voltage response depends in a unique way on the type and concentration of ambient gas. Most electrocatalytic sensors have symmetrical structure. They are in a form of pellets with two electrodes placed on their opposite sides. Electrochemical reactions occur simultaneously on both electrodes. In this paper results for sensors with only one active electrode exposed to ambient gas are presented. The other electrode was isolated from ambient gas with dielectric sealing. This sensor construction allows application of advanced measuring procedures, which permit sensor regeneration acceleration. Experiments were conducted on Nasicon sensors. Properties of two sensors, one with one active electrode and second with symmetrical structure, used for the detection of mixtures of NO{sub 2} and synthetic air are compared.

  6. The 12B counter: an active dosemeter for high-energy neutrons.

    Science.gov (United States)

    Leuschner, A

    2005-01-01

    High-energy accelerators can produce strong time-structured radiation fields. Such dose shots are generated at linear machines with low duty cycles as well as at circular machines when complete fills are instantaneously lost. The main dose component behind thick shielding is due to high-energy neutrons occurring at that time structure. Dosemeters based on Geiger-Mueller tubes or proportional counters fail here completely. The 12B counter, a novel dosemeter made of a plastic scintillator using carbon activation for event-like exposure, has been introduced. High-energy neutrons activate the carbon nuclei by three inelastic reactions. The decay patterns with half-lives between 20 ms and 20 min can be exploited depending on the time structure of the radiation field. The response of the 12B counter was measured along with some other dosemeters, both active and passive, in the radiation field behind the lateral concrete shielding of a 7.5 GeV proton transfer line.

  7. Experimental determination of detection limits for performing neutron activation analysis for gold in the field

    Energy Technology Data Exchange (ETDEWEB)

    Jarzemba, M.S.; Weldy, J.; Pearcy, E.; Prikryl, J.; Pickett, D.

    1999-11-01

    Measurements are presented of gold concentration in rock/soil samples by delayed neutron activation analysis using a device and method that are potentially field portable. The device consists of a polyethylene moderator and {sup 252}Cf as the source of neutrons for activating the samples and a high-purity germanium detector to measure the 412-keV gamma-ray emissions from activated gold. This information is used to extract the gold concentration in the sample. Two types of samples were investigated: (1) pure SiO{sub 2} doped with a known amount of gold chloride and (2) US Geological Survey standards. The former types were used to evaluate optimum device performance and to calibrate the device and method. The latter types were used to show typical system performance for the intended application (field exploration for gold deposits). It was found that the device was capable of determining gold concentrations to {approximately}10 ppb with a turnaround time (the sum of irradiation, decay, and counting times) of {approximately}10 days. For samples where the gold concentration was much higher (i.e., gold ore), turnaround times are {approximately}2 days and could be shortened further by sacrificing accuracy (e.g., lessening irradiation, decay, and counting times) or by augmenting source strength.

  8. Development of Pneumatic Transfer Irradiation Facility (PTS no.2) for Neutron Activation Analysis at HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Kim, S. H.; Sun, G. M.; Baek, S. Y.; Kim, H. R.; Kim, Y. J

    2008-03-15

    A pneumatic transfer irradiation system (PTS) is one of the most important facilities used during neutron irradiation of a target material for instrumental neutron activation analysis (INAA) in a research reactor. In particular, a fast pneumatic transfer system is essential for the measurement of a short half-life nuclide and a delayed neutron counting system. The pneumatic transfer irradiation system (PTS no.2) involving a manual system and an automatic system for delayed neutron activation analysis (DNAA) were reconstructed with new designs of a functional improvement at the HANARO research reactor in 2006. In this technical report, the conception, design, operation and control of PTS no.2 was described. Also the experimental results and the characteristic parameters measured by a mock-up test, a functional operation test and an irradiation test of these systems, such as the transfer time of irradiation capsule, automatic operation control by personal computer, delayed neutron counting system, the different neutron flux, the temperature of the irradiation position with an irradiation time, the radiation dose rate when the rabbit is returned, etc. are reported to provide a user information as well as a reactor's management and safety.

  9. Toward real time detection of the basic living activity in home using a wearable sensor and smart home sensors.

    Science.gov (United States)

    Bang, Sunlee; Kim, Minho; Song, Sa-Kwang; Park, Soo-Jun

    2008-01-01

    As the elderly people living alone are enormously increasing recently, we need the system inferring activities of daily living (ADL) for maintaining healthy life and recognizing emergency. The system should be constructed with sensors, which are used to associate with people's living while remaining as non intrusive views as possible. To do this, the proposed system use a triaxial accelerometer sensor and environment sensors indicating contact with subject in home. Particularly, in order to robustly infer ADLs, we present component ADL, which is decided with conjunction of human motion together, not just only contacted object identification. It is an important component in inferring ADL. In special, component ADL decision firstly refines misclassified initial activities, which improves the accuracy of recognizing ADL. Preliminary experiments results for proposed system provides overall recognition rate of over 97% over 8 component ADLs, which can be effectively applicable to recognize the final ADLs.

  10. Application and facility of neutron activation analysis in HANARO research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y.S. [Korea Atomic Energy Research Institute, Taejon (Korea)

    2001-11-01

    The facilities for neutron activation analysis in the HANARO research reactor are described and the main applications of NAA in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, were installed at three irradiation holes at the end of 1995. One irradiation hole is lined with a cadmium tube for epithermal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and custom made polythylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3 x 10{sup 13} {approx} 1 x 10{sup 14} n/cm{sup 2}{center_dot}s and cadmium ratios are 15 {approx} 250. For an automatic sample changer for gamma-ray counting, a domestic product was designed and manufactured. An integrated computer program (Labview) for the calculation of content was developed. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Improvement of analytical procedures and establishment of an analytical quality control and assurance system were studied. Applied research and development for the environment, industry and human health by NAA and its standardization was carried out. For the application of the Korea Laboratory Accreditation Scheme (KOLAS), evaluation of measurement uncertainty and proficiency testing of reference materials was performed. Also to verify the reliability and validity of analytical results, intercomparison studies between laboratories were carried out. In this paper, analytical services, national cooperation and the results of the researches are summarized. (author)

  11. Complex Human Activity Recognition Using Smartphone and Wrist-Worn Motion Sensors

    NARCIS (Netherlands)

    Shoaib, Muhammad; Bosch, Stephan; Durmaz Incel, Ozlem; Scholten, Hans; Havinga, Paul J.M.

    2016-01-01

    The position of on-body motion sensors plays an important role in human activity recognition. Most often, mobile phone sensors at the trouser pocket or an equivalent position are used for this purpose. However, this position is not suitable for recognizing activities that involve hand gestures, such

  12. 77 FR 52317 - Record of Decision for Surveillance Towed Array Sensor System Low Frequency Active Sonar

    Science.gov (United States)

    2012-08-29

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF DEFENSE Department of the Navy Record of Decision for Surveillance Towed Array Sensor System Low Frequency Active... Array Sensor System Low Frequency Active (SURTASS LFA) sonar systems with certain geographical...

  13. Neutron flux measurements at the TRIGA reactor in Vienna for the prediction of the activation of the biological shield

    Energy Technology Data Exchange (ETDEWEB)

    Merz, Stefan [Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna (Austria); Djuricic, Mile [Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna (Austria); Nuclear Engineering Seibersdorf, 2444 Seibersdorf (Austria); Villa, Mario; Boeck, Helmuth [Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna (Austria); Steinhauser, Georg, E-mail: georg.steinhauser@ati.ac.at [Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna (Austria)

    2011-11-15

    The activation of the biological shield is an important process for waste management considerations of nuclear facilities. The final activity can be estimated by modeling using the neutron flux density rather than the radiometric approach of activity measurements. Measurement series at the TRIGA reactor Vienna reveal that the flux density next to the biological shield is in the order of 10{sup 9} cm{sup -2} s{sup -1} at maximum power; but it is strongly influenced by reactor installations. The data allow the estimation of the final waste categorization of the concrete according to the Austrian legislation. - Highlights: > Neutron activation is an important process for the waste management of nuclear facilities. > Biological shield of the TRIGA reactor Vienna has been topic of investigation. > Flux values allow a categorization of the concrete concerning radiation protection legislation. > Reactor installations are of great importance as neutron sources into the biological shield. > Every installation shows distinguishable flux profiles.

  14. Impact of Sensor Misplacement on Dynamic Time Warping Based Human Activity Recognition using Wearable Computers.

    Science.gov (United States)

    Kale, Nimish; Lee, Jaeseong; Lotfian, Reza; Jafari, Roozbeh

    2012-10-01

    Daily living activity monitoring is important for early detection of the onset of many diseases and for improving quality of life especially in elderly. A wireless wearable network of inertial sensor nodes can be used to observe daily motions. Continuous stream of data generated by these sensor networks can be used to recognize the movements of interest. Dynamic Time Warping (DTW) is a widely used signal processing method for time-series pattern matching because of its robustness to variations in time and speed as opposed to other template matching methods. Despite this flexibility, for the application of activity recognition, DTW can only find the similarity between the template of a movement and the incoming samples, when the location and orientation of the sensor remains unchanged. Due to this restriction, small sensor misplacements can lead to a decrease in the classification accuracy. In this work, we adopt DTW distance as a feature for real-time detection of human daily activities like sit to stand in the presence of sensor misplacement. To measure this performance of DTW, we need to create a large number of sensor configurations while the sensors are rotated or misplaced. Creating a large number of closely spaced sensors is impractical. To address this problem, we use the marker based optical motion capture system and generate simulated inertial sensor data for different locations and orientations on the body. We study the performance of the DTW under these conditions to determine the worst-case sensor location variations that the algorithm can accommodate.

  15. Flexible and Stretchable Physical Sensor Integrated Platforms for Wearable Human-Activity Monitoringand Personal Healthcare.

    Science.gov (United States)

    Trung, Tran Quang; Lee, Nae-Eung

    2016-06-01

    Flexible and stretchable physical sensors that can measure and quantify electrical signals generated by human activities are attracting a great deal of attention as they have unique characteristics, such as ultrathinness, low modulus, light weight, high flexibility, and stretchability. These flexible and stretchable physical sensors conformally attached on the surface of organs or skin can provide a new opportunity for human-activity monitoring and personal healthcare. Consequently, in recent years there has been considerable research effort devoted to the development of flexible and stretchable physical sensors to fulfill the requirements of future technology, and much progress has been achieved. Here, the most recent developments of flexible and stretchable physical sensors are described, including temperature, pressure, and strain sensors, and flexible and stretchable sensor-integrated platforms. The latest successful examples of flexible and stretchable physical sensors for the detection of temperature, pressure, and strain, as well as their novel structures, technological innovations, and challenges, are reviewed first. In the next section, recent progress regarding sensor-integrated wearable platforms is overviewed in detail. Some of the latest achievements regarding self-powered sensor-integrated wearable platform technologies are also reviewed. Further research direction and challenges are also proposed to develop a fully sensor-integrated wearable platform for monitoring human activity and personal healthcare in the near future.

  16. Summary report for ITER task - D10: Update and implementation of neutron transport and activation codes and processed libraries

    Energy Technology Data Exchange (ETDEWEB)

    Attaya, H.

    1995-01-01

    The primary goal of this task is to provide the capabilities in the activation code RACC, to treat pulsed operation modes. In addition, it is required that the code utilizes the same spatial mesh and geometrical models as employed in the one or multidimensional neutron transport codes used in ITER design. This would ensure the use of the same neutron flux generated by those codes to calculate the different activation parameters. It is also required to have the capabilities for generating graphical outputs for the calculated activation parameters.

  17. Human movement activity classification approaches that use wearable sensors and mobile devices

    Science.gov (United States)

    Kaghyan, Sahak; Sarukhanyan, Hakob; Akopian, David

    2013-03-01

    Cell phones and other mobile devices become part of human culture and change activity and lifestyle patterns. Mobile phone technology continuously evolves and incorporates more and more sensors for enabling advanced applications. Latest generations of smart phones incorporate GPS and WLAN location finding modules, vision cameras, microphones, accelerometers, temperature sensors etc. The availability of these sensors in mass-market communication devices creates exciting new opportunities for data mining applications. Particularly healthcare applications exploiting build-in sensors are very promising. This paper reviews different approaches of human activity recognition.

  18. In vivo neutron activation analysis: body composition studies in health and disease

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, K.J.; Cohn, S.H.

    1984-01-01

    In vivo analysis of body elements by neutron activation is an important tool in medical research. It has provided a direct quantitative measure of body composition of human beings in vivo. Basic physiological differences related to age, sex, race, and body size have been assessed by this noninvasive technique. The diagnosis and management of patients with various metabolic disorders and diseases has also been demonstrated. Two major facilities at Brookhaven are being utilized exclusively for in vivo neutron activation analysis (IVNAA) of calcium, phosphorus, sodium, chlorine, nitrogen, hydrogen, and potassium. These elements serve as the basis for a four compartment model of body composition: protein, water, mineral ash, and fat. Variations in these compartments are demonstrated in clinical research programs investigating obesity, anorexia, cancer, renal failure, osteoporosis, and normal aging. IVNAA continues to provide a unique approach to the evaluation of clinical diagnosis, efficacy of therapeutic regimens, and monitoring of the aging process. Classical balance studies usually require the patient to be admitted to a hospital for extended periods of confinement. IVNAA, however, allows for clinical management of the patient on an out-patient basis, an important aspect for treatment of chronic diseases. 25 references, 3 figures, 5 tables.

  19. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    Science.gov (United States)

    Parrado, G.; Cañón, Y.; Peña, M.; Sierra, O.; Porras, A.; Alonso, D.; Herrera, D. C.; Orozco, J.

    2016-07-01

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  20. Preparation of palladium impregnated alumina adsorbents: Thermal and neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, Sumanta; Gupta, N.K.; Roy, S.P.; Dash, S.; Kumar, A.; Bamankar, Y.R.; Rao, T.V. Vittal [Product Development Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kumar, N. [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Naik, Y., E-mail: ynaik@barc.gov.in [Product Development Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2016-02-10

    Highlights: • Pd/Al{sub 2}O{sub 3} composite microspheres particles with high surface area were prepared sol–gel process. • Scanning electron microscopy (SEM) studies on silver coated particle. • Content of the palladium was determined using Neutron Activation Analysis (NAA). • Decomposition study has been done by quadrupole mass analyser. - Abstract: Pd/Al{sub 2}O{sub 3} composite microspheres particles with high surface area were prepared sol–gel process. The decomposition of dried gel-particles was studied by TGA/DTA and FT-IR technique. TGA studies indicated that formation of palladium is marked by a broad exothermic peak with a loss of water and oxidation of trapped HMTA/Urea nitrate mixture. The main decomposition reaction took place in the temperature range of 660–1250 K in helium and relatively lower temperature of 400 K to 1250 K in oxygen. Optical microscopy indicated that the distribution of palladium is uniform. SEM studies on silver coated particle indicated that there was surface erosion of some gel spheres while in few of them micro cracks were seen at high resolution. Content of the palladium was determined using Neutron Activation Analysis (NAA). Decomposition at various temperatures was studied using Residual gas analyser and decomposition species were identified using quadrupole mass analyser.

  1. Determination of uranium and thorium by neutron activation analysis applied to fossil samples dating

    Energy Technology Data Exchange (ETDEWEB)

    Ticianelli, Regina B.; Figueiredo, Ana Maria Graciano; Zahn, Guilherme S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Kinoshita, Angela; Baffa, Oswaldo [Universidade de Sao Paulo (FFCRLP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto. Dept. de Fisica

    2011-07-01

    Electron Spin Resonance (ESR) dating is based on the fact that ionizing radiation can create stable free radicals in insulating materials, like tooth enamel and bones. The concentration of these radicals - determined by ESR - is a function of the dose deposed in the sample along the years. The accumulated dose of radiation, called Archaeological Dose, is produced by the exposition to environmental radiation provided by U, Th, K and cosmic rays. If the environmental dose rate in the site where the fossil sample is found is known, it is possible to convert this dose into the age of the sample. The annual dose rate coming from the radioactive elements present in the soil and in the sample itself can be calculated by determining the U, Th and K concentration. Therefore, the determination of the dose rate depends on the concentration of these main radioactive elements. Neutron Activation Analysis has the sensitivity and the accuracy necessary to determine U, Th and K with this objective. Depending on the composition of the sample, the determination of U and Th can be improved irradiating the sample inside a Cd capsule, reducing the thermal neutron incidence on the sample and, therefore, diminishing the activation of possible interfering nuclides. In this study the optimal irradiation and counting conditions were established for U and Th determination in fossil teeth and soil. (author)

  2. Active detection of small quantities of shielded highly-enriched uranium using low-dose 60-kev neutron interrogation

    Science.gov (United States)

    Kerr, Phil; Rowland, Mark; Dietrich, Dan; Stoeffl, Wolfgang; Wheeler, Boyd; Nakae, Les; Howard, Doug; Hagmann, Chris; Newby, Jason; Porter, Robert

    2007-08-01

    Active interrogation with low-energy neutrons provides a search technique for highly-enriched uranium concealed in cargo. We describe the technique and show initial results using a low-dose 60-keV neutron beam. This technique produces a clear induced fission signal in the presence of small quantities of 235U. The technique has been validated with low-Z and high-Z cargo materials. The technique uses a forward-directed beam of 60-keV neutrons to induce fission in 235U. Detection of the fast fission neutrons with pulse-shape discriminating scintillators is then the signature for 235U. The beam of neutrons is generated with a 1.93 MeV proton beam impinging on a natural lithium target. The proton beam is produced by a radio-frequency quadrupole LINAC. The 60 keV neutron beam is forward-directed because the 7Li(p, n) reaction is just above threshold for a proton energy of 1.93 MeV.

  3. Self-Activated Transparent All-Graphene Gas Sensor with Endurance to Humidity and Mechanical Bending.

    Science.gov (United States)

    Kim, Yeon Hoo; Kim, Sang Jin; Kim, Yong-Jin; Shim, Yeong-Seok; Kim, Soo Young; Hong, Byung Hee; Jang, Ho Won

    2015-10-27

    Graphene is considered as one of leading candidates for gas sensor applications in the Internet of Things owing to its unique properties such as high sensitivity to gas adsorption, transparency, and flexibility. We present self-activated operation of all graphene gas sensors with high transparency and flexibility. The all-graphene gas sensors which consist of graphene for both sensor electrodes and active sensing area exhibit highly sensitive, selective, and reversible responses to NO2 without external heating. The sensors show reliable operation under high humidity conditions and bending strain. In addition to these remarkable device performances, the significantly facile fabrication process enlarges the potential of the all-graphene gas sensors for use in the Internet of Things and wearable electronics.

  4. Neutron activation analysis at the Livermore pool-type reactor for the environmental research program. [Identification of trace element contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Ragaini, R.C.; Heft, R.E.; Garvis, D.

    1976-07-02

    Instrumental neutron activation analysis is a technique of trace analysis using measurements of radioactivity induced in the sample by exposure to a source of neutrons. The induced activity is measured by the emitted gamma radiation. Each gamma emitter can then be identified by the energy of the photopeaks produced as the nuclide decays and by the half-life of the neutron-induced activity. A complex computer program GAMANAL has been used to accomplish the major tasks of nuclide identification and quantification. The nuclide data output from GAMANAL is processed by a second computer code NADAC, which develops elemental abundance data from disintegration rates observed. The methods are those employed at the Livermore Pool-Type Reactor in support of the environmental research trace element analysis program. Among the procedures described and discussed are sample preparation, irradiation, analysis, and application of the technique.

  5. Monte-Carlo Simulations of Radiation-Induced Activation in a Fast-Neutron and Gamma- Based Cargo Inspection System

    CERN Document Server

    Bromberger, B; Brandis, M; Dangendorf, V; Goldberg, M B; Kaufmann, F; Mor, I; Nolte, R; Schmiedel, M; Tittelmeier, K; Vartsky, D; Wershofen, H

    2012-01-01

    An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspection facility is the inventory and lifetimes of radioactive isotopes produced by the neutron and gamma radiation inside the cargo, as well as the dose delivered by these isotopes to people in contact with the cargo during and following the interrogation procedure. Using MCNPX and CINDER90 we have calculated the activation levels for several typical inspection scenarios. One example is the activation of various metal samples embedded in a cotton-filled container. To validate the simulation results, a benchmark experiment was performed, in which metal samples were activated by fast-neutrons in a water-filled glass jar. T...

  6. Neutron, gamma and Roentgen fluorescent activation analysis of hair of children suffering from bronchial asthma

    Energy Technology Data Exchange (ETDEWEB)

    Alekseeva, O.A.; Belov, A.G.; Frontasyeva, M.V.; Gundorina, S.F.; Gustova, M.V.; Kusmenko, L.G.; Perelygin, V.P. E-mail: pergam@cv.jinr.ru; Zaverioukha, O.S

    2001-06-01

    The aim of present study was the multiparametric study of dangerous microelements content in the hair of children under school and primary school age which included 12 children ill with bronchial asthma and 11 control group persons in the town of Troitsk, Moscow Region. The hair specimens with weight 15-220 mg were analysed with the application of epithermal neutron activation analysis conducted at experimental installation REGATA and neutron source-unique Pulsed Fast Reactor IBR-2, with the application of combined gamma-neutron irradiation at Microtron MT-25 and with Roentgen Fluorescence Analysis device of JINR. The data of elements content in hair were obtained with solid state track detectors and semiconductor electronic spectrometers. The solid state track detectors provide the determination of U, Th, Bi and Be elements at the level of sensitivity up to 10{sup -8}-10{sup -9} g/g. These data were compared with more representative information about dangerous microelements concentration obtained with NAA and RFA analyses. The obtained concentrations of most elements vary in a wide range, but in agreement with the known data. The highest degree of element dispersion was observed for U, Th, Pb, I, Br, Sb, Co, K and Be (the radiation coefficient was higher than 100-200%). The presented analysis of results shows that in the clinical picture there is some proved correlation between an increased content of some element in hair and symptoms of their accumulation in the organism of ill children, the revelation of which is the basic idea of our examination.

  7. Submersible microbial fuel cell sensor for monitoring microbial activity and BOD in groundwater: Focusing on impact of anodic biofilm on sensor applicability

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Angelidaki, Irini

    2011-01-01

    A sensor, based on a submersible microbial fuel cell (SUMFC), was developed for in situ monitoring of microbial activity and biochemical oxygen demand (BOD) in groundwater. Presence or absence of a biofilm on the anode was a decisive factor for the applicability of the sensor. Fresh anode...... was required for application of the sensor for microbial activity measurement, while biofilm‐colonized anode was needed for utilizing the sensor for BOD content measurement. The current density of SUMFC sensor equipped with a biofilm‐colonized anode showed linear relationship with BOD content, to up to 250 mg...

  8. Evaluation of neutron flux parameters in irradiation sites of research reactor using the Westcott-formalism for the k0 neutron activation analysis method

    Science.gov (United States)

    Kasban, H.; Hamid, Ashraf

    2015-12-01

    Instrumental Neutron Activation Analysis using k0 (k0-INAA) method has been used to determine a number of elements in sediment samples collected from El-Manzala Lake in Egypt. k0-INAA according to Westcott's formalism has been implemented using the complete irradiation kit of the fast pneumatic rabbit and some selected manually loaded irradiation sites for short and long irradiation at Egypt Second Research Reactor (ETRR-2). Zr-Au and Co sets as neutron flux monitors are used to determine the neutron flux parameters (f and α) in each irradiation sites. Two reference materials IAEA Soil-7 samples have been inserted and implemented for data validation and an internal monostandard multi monitor used (k0 based IM-NAA). It was given a good agreement between the experimental analyzed values and that obtained of the certified values. The major and trace elements in the sediment samples have been evaluated with the use of Co as an internal and Au as an external monostandard comparators. The concentrations of the elements (Cr, Mn and Zn) in the sediment samples of the present work are discussed regarding to those obtained from other sites.

  9. Trace elements determination in human bone tissue by neutron activation analysis; Determinacao de elementos de traco em tecido osseo humano pelo metodo de ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Marcelo K.; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Div. de Radioquimica; Sumita, Nairo M.; Saldiva, Paulo H.N.; Pasqualucci, Carlos A. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Lab. Experimental de Poluicao Atmosferica

    2002-07-01

    Determination of trace elements in human bones is of the great interest for evaluating nutritional state and for prevention, control and study of several diseases caused by mineral or trace element imbalance. In this study, neutron activation analysis (NAA) was applied for trace elements in human rib bone tissue. Elements Ba, Br, Ca, Cl, Fe, K, Mg, Mn, Na, P, Rb, Sr and Zn were determined in total bone tissue and in its subcompartments (cortical and trabecular tissue) separately. Irradiations were performed at IEA-R1 nuclear research reactor of IPEN-CNEN/SP. Short irradiations of 4 minutes were carried out under thermal neutron flux of 4.5x10{sup 11} n cm{sup -2} s{sup -1} and long irradiations of 16 hours under neutron flux of 10{sup 12} n cm{sup -2} s{sup -1}. Results obtained showed a variability between elemental concentrations found for bones from different individuals. A comparative study made between the data obtained for cortical and trabecular bones indicated that these two tissues present different elemental concentrations. Concentrations of Ca, Mg, Na and P obtained for cortical tissue were the same magnitude of those published data. (author)

  10. Contribution to the determination of Sb-Ag-Cu-Ga-Mo-Zn using 14 MeV neutron activation; Contribution au dosage de Sb-Ag-Cu-Ga-Mo-Zn par activation aux neutrons de 14 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Crambes, M. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1966-04-01

    By using, 14 MeV, neutron irradiation it is possible to extend the field of application of neutron radio-activation analysis, in particular to the case of light elements. For, many other elements it can replace in-pile irradiation thereby making it possible, thanks to portable 14 MeV neutron generators, to carry out radio-activation analyses away from nuclear-research c e n t r e s. With a view to applying this analytical technique to routine work, we have developed some rapid chemical separation methods in order to make possible the determination of several elements which after exposure to fast neutrons, produce {beta} emitting nuclides which cannot be differentiated by a simple instrumental study, the emitted radiation being of the same type and of similar half-life the two cases. (author) [French] L'irradiation au moyen de neutrons de 14 MeV permet d'etendre le domaine d'application de l'analyse par radioactivation neutronique, en particulier aux elements legers. Cependant pour de nombreux autres elements elle peut remplacer l'irradiation en reacteur nucleaire permettant ainsi grace aux ensembles portables producteurs de neutrons de 14 MeV, l'extension de l'analyse par radioactivation a l'exterieur des centres d'etudes nucleaires. Dans le but d'appliquer cette methode d'analyse a des travaux de routine, nous avons mis au point des separations chimiques rapides, afin de permettre le dosage de quelques elements qui par irradiation aux neutrons rapides, engendrent des nucleides emetteurs {beta} qu'une simple etude instrumentale ne peut differencier en raison de l'identite de leur rayonnement et de leurs periodes radioactives trop proches. (auteur)

  11. Applied research and development of neutron activation analysis - The study on human health and environment by neutron activation analysis of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seung Yeon; Yoo, Jong Ik; Lee, Jae Kwang; Lee, Sung Jun; Lee, Sang Sun; Jeon, Ki Hong; Na, Kyung Won; Kang, Sang Hun [Yonsei University, Seoul (Korea)

    2000-04-01

    With the development of the precise quantitative analytical method for the analysis of trace elements in the various biological samples such as hair and food, evaluation in view of health and environment to the trace elements in various sources which can be introduced inside human body was done. The trace elemental distribution in Korean total diet and representative food stuff was identified first. With the project the elemental distributions in supplemental healthy food and Korean and Chinese origin oriental medicine were identified. The amount of trace elements ingested with the hair analysis of oriental medicine takers were also estimated. The amounts of trace elements inhaled with the analysis of foundry air, blood and hair of foundry workers were also estimated. The basic estimation method in view of health and environment with the neutron activation analysis of biological samples such as foods and hair was established with the result. Nationwide usage system of the NAA facility in Hanaro in many different and important areas of biological area can be initiated with the results. The output of the project can support public heath, environment, and medical research area. The results can be applied for the process of micronutrients enhanced health food production and for the health safety and health status enhancement with the additional necessary data expansion and the development of various evaluation technique. 19 refs., 7 figs., 23 tabs. (Author)

  12. Sensor Data Acquisition and Processing Parameters for Human Activity Classification

    Directory of Open Access Journals (Sweden)

    Sebastian D. Bersch

    2014-03-01

    Full Text Available It is known that parameter selection for data sampling frequency and segmentation techniques (including different methods and window sizes has an impact on the classification accuracy. For Ambient Assisted Living (AAL, no clear information to select these parameters exists, hence a wide variety and inconsistency across today’s literature is observed. This paper presents the empirical investigation of different data sampling rates, segmentation techniques and segmentation window sizes and their effect on the accuracy of Activity of Daily Living (ADL event classification and computational load for two different accelerometer sensor datasets. The study is conducted using an ANalysis Of VAriance (ANOVA based on 32 different window sizes, three different segmentation algorithm (with and without overlap, totaling in six different parameters and six sampling frequencies for nine common classification algorithms. The classification accuracy is based on a feature vector consisting of Root Mean Square (RMS, Mean, Signal Magnitude Area (SMA, Signal Vector Magnitude (here SMV, Energy, Entropy, FFTPeak, Standard Deviation (STD. The results are presented alongside recommendations for the parameter selection on the basis of the best performing parameter combinations that are identified by means of the corresponding Pareto curve.

  13. Integrated Structural Health Assessment Using Piezoelectric Active Sensors

    Directory of Open Access Journals (Sweden)

    Jeannette R. Wait

    2005-01-01

    Full Text Available This paper illustrates an integrated approach for identifying structural damage. The method presented utilizes piezoelectric (PZT materials to actuate/sense the dynamic response of the structures. Two damage identification techniques are integrated in this study, including impedance methods and Lamb wave propagations. The impedance method monitors the variations in structural mechanical impedance, which is coupled with the electrical impedance of the PZT patch. In Lamb wave propagations, one PZT patch acting as an actuator launches an elastic wave through the structure, and responses are measured by an array of PZT sensors. The changes in both wave attenuation and reflection are used to detect and locate the damage. Both the Lamb wave and impedance methods operate in high frequency ranges at which there are measurable changes in structural responses even for incipient damage such as small cracks, debonding, or loose connections. The combination of the local impedance method with the wave propagation based approach allows a better characterization of the system’s structural integrity. The paper concludes with experimental results to demonstrate the feasibility of this integrated active sensing technology.

  14. Confronting Passive and Active Sensors with Non-Gaussian Statistics

    Directory of Open Access Journals (Sweden)

    Pablo Rodríguez-Gonzálvez

    2014-07-01

    Full Text Available This paper has two motivations: firstly, to compare the Digital Surface Models (DSM derived by passive (digital camera and by active (terrestrial laser scanner remote sensing systems when applied to specific architectural objects, and secondly, to test how well the Gaussian classic statistics, with its Least Squares principle, adapts to data sets where asymmetrical gross errors may appear and whether this approach should be changed for a non-parametric one. The field of geomatic technology automation is immersed in a high demanding competition in which any innovation by one of the contenders immediately challenges the opponents to propose a better improvement. Nowadays, we seem to be witnessing an improvement of terrestrial photogrammetry and its integration with computer vision to overcome the performance limitations of laser scanning methods. Through this contribution some of the issues of this “technological race” are examined from the point of view of photogrammetry. A new software is introduced and an experimental test is designed, performed and assessed to try to cast some light on this thrilling match. For the case considered in this study, the results show good agreement between both sensors, despite considerable asymmetry. This asymmetry suggests that the standard Normal parameters are not adequate to assess this type of data, especially when accuracy is of importance. In this case, standard deviation fails to provide a good estimation of the results, whereas the results obtained for the Median Absolute Deviation and for the Biweight Midvariance are more appropriate measures.

  15. Ammonia sensor and antibacterial activities of green zinc oxide nanoparticles

    Directory of Open Access Journals (Sweden)

    S. Khaleel Basha

    2016-09-01

    Full Text Available Zinc oxide nanoparticles was synthesized by alginate (A through a rapid and a facile step in the aqueous solution condition at room temperature. Fabrication of zinc oxide nanoparticles was characterized by ATR-FTIR, TEM and XRD. ATR-FTIR analysis confirmed that the A/ZnO NPs were encapsulated by the polymerized alginate. Their shape, structure and composition were assessed by SEM. TEM and XRD analysis indicated that the A/ZnO NPs give evidence of the crystalline nature of ZnO and hybrid NPs structure, which is suitable for ammonia gas sensor development. The controlled size of the A/ZnO NPs obtained using this innovative synthesis strategy minimizes the response time of 2–3 s to sense the ammonia gas significantly with a detection limit of 1 ppm were found at room temperature. The antibacterial tests revealed that the A/ZnO NPs exhibits a potent activity against gram positive and gram negative bacteria.

  16. Structural integrated sensor and actuator systems for active flow control

    Science.gov (United States)

    Behr, Christian; Schwerter, Martin; Leester-Schädel, Monika; Wierach, Peter; Dietzel, Andreas; Sinapius, Michael

    2016-04-01

    An adaptive flow separation control system is designed and implemented as an essential part of a novel high-lift device for future aircraft. The system consists of MEMS pressure sensors to determine the flow conditions and adaptive lips to regulate the mass flow and the velocity of a wall near stream over the internally blown Coanda flap. By the oscillating lip the mass flow in the blowing slot changes dynamically, consequently the momentum exchange of the boundary layer over a high lift flap required mass flow can be reduced. These new compact and highly integrated systems provide a real-time monitoring and manipulation of the flow conditions. In this context the integration of pressure sensors into flow sensing airfoils of composite material is investigated. Mechanical and electrical properties of the integrated sensors are investigated under mechanical loads during tensile tests. The sensors contain a reference pressure chamber isolated to the ambient by a deformable membrane with integrated piezoresistors connected as a Wheatstone bridge, which outputs voltage signals depending on the ambient pressure. The composite material in which the sensors are embedded consists of 22 individual layers of unidirectional glass fiber reinforced plastic (GFRP) prepreg. The results of the experiments are used for adapting the design of the sensors and the layout of the laminate to ensure an optimized flux of force in highly loaded structures primarily for future aeronautical applications. It can be shown that the pressure sensor withstands the embedding process into fiber composites with full functional capability and predictable behavior under stress.

  17. Thin n-in-p planar pixel sensors and active edge sensors for the ATLAS upgrade at HL-LHC

    CERN Document Server

    Terzo, Stefano; Nisius, R.; Paschen, B.

    2014-01-01

    Silicon pixel modules employing n-in-p planar sensors with an active thickness of 200 $\\mu$m, produced at CiS, and 100-200 $\\mu$m thin active/slim edge sensor devices, produced at VTT in Finland have been interconnected to ATLAS FE-I3 and FE-I4 read-out chips. The thin sensors are designed for high energy physics collider experiments to ensure radiation hardness at high fluences. Moreover, the active edge technology of the VTT production maximizes the sensitive region of the assembly, allowing for a reduced overlap of the modules in the pixel layer close to the beam pipe. The CiS production includes also four chip sensors according to the module geometry planned for the outer layers of the upgraded ATLAS pixel detector to be operated at the HL-LHC. The modules have been characterized using radioactive sources in the laboratory and with high precision measurements at beam tests to investigate the hit efficiency and charge collection properties at different bias voltages and particle incidence angles. The perfo...

  18. Pulsed and monoenergetic beams for neutron cross-section measurements using activation and scattering techniques at Triangle Universities Nuclear Laboratory

    Science.gov (United States)

    Hutcheson, A.; Angell, C. T.; Becker, J. A.; Boswell, M.; Crowell, A. S.; Dashdorj, D.; Fallin, B.; Fotiades, N.; Howell, C. R.; Karwowski, H. J.; Kelley, J. H.; Kiser, M.; Macri, R. A.; Nelson, R. O.; Pedroni, R. S.; Tonchev, A. P.; Tornow, W.; Vieira, D. J.; Weisel, G. J.; Wilhelmy, J. B.

    2007-08-01

    In support of the Stewardship Science Academic Alliances initiative, an experimental program has been developed at Triangle Universities Nuclear Laboratory (TUNL) to measure (n,xn) cross-sections with both in-beam and activation techniques with the goal of improving the partial cross-section database for the NNSA Stockpile Stewardship Program. First experimental efforts include excitation function measurements on 235,238U and 241Am using pulsed and monoenergetic neutron beams with En = 5-15 MeV. Neutron-induced partial cross-sections were measured by detecting prompt γ rays from the residual nuclei using various combinations of clover and planar HPGe detectors in the TUNL shielded neutron source area. Complimentary activation measurements using DC neutron beams have also been performed in open geometry in our second target area. The neutron-induced activities were measured in the TUNL low-background counting area. In this presentation, we include detailed information about the irradiation procedures and facilities and preliminary data on first measurements using this capability.

  19. Pulsed and monoenergetic beams for neutron cross-section measurements using activation and scattering techniques at Triangle Universities Nuclear Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hutcheson, A. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States)]. E-mail: hutch@tunl.duke.edu; Angell, C.T. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Becker, J.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Boswell, M. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Crowell, A.S. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Dashdorj, D. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Fallin, B. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Fotiades, N. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Howell, C.R.; Karwowski, H.J.; Kelley, J.H.; Kiser, M. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Macri, R.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Nelson, R.O. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Pedroni, R.S. [NC A and T State University, 1601 East Market Street, Greensboro, NC 27411 (United States); Tonchev, A.P.; Tornow, W. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Vieira, D.J. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Weisel, G.J. [Penn State Altoona, 3000 Ivyside Park, Altoona, PA 16601 (United States); Wilhelmy, J.B. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States)

    2007-08-15

    In support of the Stewardship Science Academic Alliances initiative, an experimental program has been developed at Triangle Universities Nuclear Laboratory (TUNL) to measure (n,xn) cross-sections with both in-beam and activation techniques with the goal of improving the partial cross-section database for the NNSA Stockpile Stewardship Program. First experimental efforts include excitation function measurements on {sup 235,238}U and {sup 241}Am using pulsed and monoenergetic neutron beams with E {sub n} = 5-15 MeV. Neutron-induced partial cross-sections were measured by detecting prompt {gamma} rays from the residual nuclei using various combinations of clover and planar HPGe detectors in the TUNL shielded neutron source area. Complimentary activation measurements using DC neutron beams have also been performed in open geometry in our second target area. The neutron-induced activities were measured in the TUNL low-background counting area. In this presentation, we include detailed information about the irradiation procedures and facilities and preliminary data on first measurements using this capability.

  20. Development of Active Pixel Photodiode Sensors for Gamma Camera Application

    CERN Document Server

    Salahuddin, Nur Sultan; Heruseto, Brahmantyo; Parmentier, Michel

    2011-01-01

    We designed new photodiodes sensors including current mirror amplifiers. These photodiodes have been fabricated using a CMOS 0.6 micrometers process from Austria Micro System (AMS). The Photodiode areas are respectiveley 1mm x 1mm and 0.4mm x 0.4mm with fill factor 98 % and total chip area is 2 square millimetres. The sensor pixels show a logarithmic response in illumination and are capable of detecting very low blue light (less than 0.5 lux) . These results allow to use our sensor in new Gamma Camera solid-state concept.

  1. Measuring glottal activity during voiced speech using a tuned electromagnetic resonating collar sensor

    Science.gov (United States)

    Brown, D. R., III; Keenaghan, K.; Desimini, S.

    2005-11-01

    Non-acoustic speech sensors can be employed to obtain measurements of one or more aspects of the speech production process, such as glottal activity, even in the presence of background noise. These sensors have a long history of clinical applications and have also recently been applied to the problem of denoising speech signals recorded in acoustically noisy environments (Ng et al 2000 Proc. Int. Conf. on Acoustics, Speech, and Signal Processing (ICASSP) (Istanbul, Turkey) vol 1, pp 229-32). Recently, researchers developed a new non-acoustic speech sensor based primarily on a tuned electromagnetic resonator collar (TERC) (Brown et al 2004 Meas. Sci. Technol. 15 1291). The TERC sensor measures glottal activity by sensing small changes in the dielectric properties of the glottis that result from voiced speech. This paper builds on the seminal work in Brown et al (2004). The primary contributions of this paper are (i) a description of a new single-mode TERC sensor design addressing the comfort and complexity issues of the original sensor, (ii) a complete description of new external interface systems used to obtain long-duration recordings from the TERC sensor and (iii) more extensive experimental results and analysis for the single-mode TERC sensor including spectrograms of speech containing both voiced and unvoiced speech segments in quiet and acoustically noisy environments. The experimental results demonstrate that the single-mode TERC sensor is able to detect glottal activity up to the fourth harmonic and is also insensitive to acoustic background noise.

  2. Analysis of umayyad islamic silver coins (Dirhams) by using instrumental neutron activation analysis

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Islamic silver coins (Dirhams) running the period between 107 to 126 Hijri (726-743AD), which belong to the Umayyad Empire period, 41-132 hijri (661-750AD), were selected for analysis by using instrumentalneutron activation analysis techniques.During this period (105-126H),(724-743AD), the Caliph Hisham Eben Abdlemalek ruled the Umayyad Empire.Dirhams were irradiated in a reactor neutron activation facility.Levels of various elements viz.Cu, Ag and Au were estimated.It was found that the average silver concentration, the baseconstituent of the Dirham, was about 88wt%.Correlation between thecomposition of Dirhams and the historical implications was discussed.

  3. Ion Uptake Determination of Dendrochronologically-Dated Trees Using Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kenan Unlu; P.I. Kuniholm; D.K.H. Schwarz; N.O. Cetiner; J.J. Chiment

    2009-03-30

    Uptake of metal ions by plan roots is a function of the type and concentration of metal in the soil, the nutrient biochemistry of the plant, and the immediate environment of the root. Uptake of gold (Au) is known to be sensitive to soil pH for many species. Soil acidification due to acid precipitation following volcanic eruptions can dramatically increase Au uptake by trees. Identification of high Au content in tree rings in dendrochronologically-dated, overlapping sequences of trees allows the identification of temporally-conscribed, volcanically-influenced periods of environmental change. Ion uptake, specifically determination of trace amounts of gold, was performed for dendrochronologically-dated tree samples utilizing Neutron Activation Analysis (NAA) technique. The concentration of gold was correlated with known enviironmental changes, e.g. volcanic activities, during historic periods.

  4. Implementation of gamma-ray instrumentation for solid solar system bodies using neutron activation method

    Energy Technology Data Exchange (ETDEWEB)

    Litvak, M.L., E-mail: litvak@mx.iki.rssi.ru [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Golovin, D.V. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Jun, I. [Jet Propulsion Laboratory, Pasadena, CA (United States); Kozyrev, A.S.; Mitrofanov, I.G.; Sanin, A.B. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Shvetsov, V.N.; Timoshenko, G.N.; Zontikov, A. [Joint Institute for Nuclear Research, Dubna (Russian Federation)

    2016-06-21

    In this paper we present the results of ground tests performed with a flight model and with industry prototypes of passive and active gamma ray spectrometers with the objective of understanding their capability to distinguish the elemental composition of planetary bodies in the solar system. The gamma instrumentation, which was developed for future space missions was used in the measurements at a special ground test facility where a simulant of planetary material was fabricated with a martian-like composition. In this study, a special attention was paid to the gamma lines from activation reaction products generated by a pulsed neutron generator. The instrumentation was able to detect and identify gamma lines attributed to O, Na, Mg, Al, Si, K, Ca and Fe.

  5. Embrittlement behaviour of different international low activation alloys after neutron irradiation

    Science.gov (United States)

    Schneider, H.-C.; Dafferner, B.; Aktaa, J.

    2001-05-01

    The embrittlement behaviour of ferritic/martensitic steels after irradiation in the Petten high flux reactor (HFR) was investigated by instrumented Charpy-V tests with subsize specimens. The main objective, apart from studying effects of particularly low doses, was a comparison of low activation alloys (LAA) from various countries with different Cr contents and different types and concentrations of minor alloying elements and impurities. In the present report, the results of another three materials (OPTIMAR, OPTIFER-IV, GA3X) obtained within the second phase of the MANITU programme (0.8 dpa, at 250-450°C) were analysed and assessed in comparison to the results of the first irradiation up to 0.8 dpa. The evaluation clearly showed a reduced embrittlement problem for the advanced reduced-activation alloys. Of the examined alloys, the GA3X steel shows the very best embrittlement behaviour after neutron irradiation.

  6. Verification of threshold activation detection (TAD) technique in prompt fission neutron detection using scintillators containing 19F

    Science.gov (United States)

    Sibczynski, P.; Kownacki, J.; Moszyński, M.; Iwanowska-Hanke, J.; Syntfeld-Każuch, A.; Gójska, A.; Gierlik, M.; Kaźmierczak, Ł.; Jakubowska, E.; Kędzierski, G.; Kujawiński, Ł.; Wojnarowicz, J.; Carrel, F.; Ledieu, M.; Lainé, F.

    2015-09-01

    In the present study ⌀ 5''× 3'' and ⌀ 2''× 2'' EJ-313 liquid fluorocarbon as well as ⌀ 2'' × 3'' BaF2 scintillators were exposed to neutrons from a 252Cf neutron source and a Sodern Genie 16GT deuterium-tritium (D+T) neutron generator. The scintillators responses to β- particles with maximum endpoint energy of 10.4 MeV from the n+19F reactions were studied. Response of a ⌀ 5'' × 3'' BC-408 plastic scintillator was also studied as a reference. The β- particles are the products of interaction of fast neutrons with 19F which is a component of the EJ-313 and BaF2 scintillators. The method of fast neutron detection via fluorine activation is already known as Threshold Activation Detection (TAD) and was proposed for photofission prompt neutron detection from fissionable and Special Nuclear Materials (SNM) in the field of Homeland Security and Border Monitoring. Measurements of the number of counts between 6.0 and 10.5 MeV with a 252Cf source showed that the relative neutron detection efficiency ratio, defined as epsilonBaF2 / epsilonEJ-313-5'', is 32.0% ± 2.3% and 44.6% ± 3.4% for front-on and side-on orientation of the BaF2, respectively. Moreover, the ⌀ 5'' EJ-313 and side-on oriented BaF2 were also exposed to neutrons from the D+T neutron generator, and the relative efficiency epsilonBaF2 / epsilonEJ-313-5'' was estimated to be 39.3%. Measurements of prompt photofission neutrons with the BaF2 detector by means of data acquisition after irradiation (out-of-beam) of nuclear material and between the beam pulses (beam-off) techniques were also conducted on the 9 MeV LINAC of the SAPHIR facility.

  7. Determination of essential elements in commercial baby foods by INAA (Instrumental Neutron Activation Analysis)

    Energy Technology Data Exchange (ETDEWEB)

    Vallinoto, Priscila; Maihara, Vera A., E-mail: pvallinoto@ipen.br, E-mail: vmaihara@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The World Health Organization recommends that infants be breast feed exclusively at least six months after birth. After this period, it is recommended to introduce complementary foods, in order to meet nutritional amounts, minerals and energy needs of children. Commercial food products intended for infants form an important part of the diet for many babies, so it is very important that such food contains sufficient amounts of minerals. Inadequate complementary feeding is a major cause of high rates of malnutrition in developing countries. In this study, essential elements: Ca, Co, Cr, Cs, Fe, K, Na and Zn levels were determined in seven different commercial food products samples by Instrumental Neutron Activation Analysis. The seven baby food samples were acquired in the markets of Sao Paulo city. After 8-hour irradiations in the IEA-R1 nuclear research reactor under a thermal neutron flux of 10{sup 12} n cm{sup -2} s{sup -1}, the essential elements were determined and the concentrations obtained were lower than the WHO requirements. For validation of the methodology, INCT MPH-2 Mixed Polish Herbs and NIST SRM 1577{sup b} Bovine Liver were analysed. (author)

  8. Flow measurement by pulsed-neutron activation techniques at the PKL facility at Erlangen (Germany). [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Kehler, P.

    1982-03-01

    Flow velocities in the downcomer at the PKL facility (in Erlangen, Germany) were measured by the Pulsed-Neutron Activation (PNA) techniques. This was the first time that a fully automated PNA system, incorporating a dedicated computer for on-line data reduction, was used for flow measurements. A prototype of a portable, pulsed, high-output neutron source, developed by the Sandia National Laboratories for the US Nuclear Regulatory Commission, was also successfully demonstrated during this test. The PNA system was the primary flow-measuring device used at the PKL, covering the whole range of velocities of interest. In this test series, the PKL simulated small-break accidents similar to the one that occurred at TMI. The flow velocities in the downcomer were, therefore, very low, ranging between 0.03 and 0.35 m/sec. Two additional flow-measuring methods were used over a smaller range of velocities. Wherever comparison was possible, the PNA-derived velocity values agreed well with the measurements performed by the two more conventional methods.

  9. Characterization of airborne particulates in Bangkok urban area by neutron activation analysis.

    Science.gov (United States)

    Nouchpramool, S; Sumitra, T; Leenanuphunt, V

    1999-01-01

    Samples of airborne particulates were collected in a residential area and in an area near a busy highway in Bangkok during the period from January 1997 to May 1998. A stacked filter system was used for the former site and a Partisol 2000 was used for the latter site. Both 2.5 microns and 10-micron particulates were collected every week. The total suspended particulate matters were also collected at the latter site. The samples were analyzed by neutron activation analysis utilizing neutron flux from a 2-MW TRIGA MARK III research reactor. The elements most frequently detected in the airborne particulates were Al, As, Br, Ca, Ce, Cl, Co, Cr, Cs, Fe, I, K, La, Mg, Mn, Na, Rb, Sb, Sc, Sm, Th, Ti, V, and Zn. The enrichment factor and factor analysis were used to investigate trends, sources, and origin of the atmospheric aerosols. Anthropogenic elements in road dust, construction dust, motor vehicles emission, and other combustion components were identified. A comparative study of data between both sites was performed and it was found that the mass concentration in the area close to the highway was about three times higher than in the residential area.

  10. Rare earth elements in core marine sediments of coastal East Malaysia by instrumental neutron activation analysis.

    Science.gov (United States)

    Ashraf, Ahmadreza; Saion, Elias; Gharibshahi, Elham; Mohamed Kamari, Halimah; Chee Kong, Yap; Suhaimi Hamzah, Mohd; Suhaimi Elias, Md

    2016-01-01

    A study was carried out on the concentration of REEs (Dy, Sm, Eu,Yb, Lu, La and Ce) that are present in the core marine sediments of East Malaysia from three locations at South China Sea and one location each at Sulu Sea and Sulawesi Sea. The sediment samples were collected at a depth of between 49 and 109 m, dried, and crushed to powdery form. The entire core sediments prepared for Instrumental Neutron Activation Analysis (INAA) were weighted approximately 0.0500 g to 0.1000 g for short irradiation and 0.1500 g to 0.2000 g for long irradiation. The samples were irradiated with a thermal neutron flux of 4.0×10(12) cm(-2) s(-1) in a TRIGA Mark II research reactor operated at 750 kW. Blank samples and standard reference materials SL-1 were also irradiated for calibration and quality control purposes. It was found that the concentration of REEs varies in the range from 0.11 to 36.84 mg/kg. The chondrite-normalized REEs for different stations suggest that all the REEs are from similar origins. There was no significant REEs contamination as the enrichment factors normalized for Fe fall in the range of 0.42-2.82. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Neutron activation of natural zinc samples at kT = 25 keV

    CERN Document Server

    Reifarth, R; Heil, M; Käppeler, F; Plag, R; Sonnabend, K; Uberseder, E

    2013-01-01

    The neutron-capture cross sections of 64Zn, 68Zn, and 70Zn have been measured with the activation technique in a quasistellar neutron spectrum corresponding to a thermal energy of kT = 25 keV. By a series of repeated irradiations with different experimental conditions, an uncertainty of 3% could be achieved for the 64Zn(n,g)65Zn cross section and for the partial cross section 68Zn(n,g)69Zn-m feeding the isomeric state in 69Zn. For the partial cross sections 70Zn(n,g)71Zn-m and 70Zn(n,g)71Zn-g, which had not been measured so far, uncertainties of only 16% and 6% could be reached because of limited counting statistics and decay intensities. Compared to previous measurements on 64,68Zn, the uncertainties could be significantly improved, while the 70Zn cross section was found to be two times smaller than existing model calculations. From these results Maxwellian average cross sections were determined between 5 and 100 keV. Additionally, the beta-decay half-life of 71Zn-m could be determined with significantly imp...

  12. A Preliminary Assessment of Radiation and Air Activation for the Neutron Science Facility in RAON

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S. C.; Lee, C. W.; Lee, E. J.; Lee, Y. O. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, J. C. [Institute for Basic Science, Daejeon (Korea, Republic of)

    2015-05-15

    The works will stay in the DAQ room during an operation for about 1 month. In order to test the characteristics of the detector, the workers are also possible to access the TOF hall after a shutdown. Therefore, the shielding analysis of the NSF is required to meet the above purpose. In view of this, we performed the calculation of the shielding concrete thickness required for a target room by using MCNPX code with a neutron source obtained from Institute for Basic Science (IBS). In addition, the dose distribution and air activation for the entire space in NSF were evaluated using MCNPX and SP-FISPACT 2010 codes. We have performed the shielding calculation with the neutron source produced from the C(d,n) reactions. The concrete thickness was evaluated for all directions of the target room, and it was confirmed by performing the calculation of dose distribution to the entire space. However, the dose rate for the beam line was high. The radioactivity of radionuclides at TOF hall do not exceeded the air concentration and release limits.

  13. Instrumental Neutron Activation Analysis- INAA: environmental studies in Das Velhas Basin, Minas Gerais, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo V, M.A.; Andrade Q, M.T. [Researcher of National Council for Scientific and Technological Development, CNPq, Center University of the East of Minas Gerais State, UNILESTE-MG (Brazil); Araujo M, R. [CDTN (Brazil); Albernaz A, I. [SCA- CNRS/USR/059, Lyon (France); Oliveira, A.H. de [Federal University of Minas Gerais State (Brazil)]. e-mail: marvv@cdtn.br

    2006-07-01

    The Instrumental Neutron Activation Analysis - INAA was applied to determine concentrations of several elements in unpolluted areas and in the mining and farming region of the Das Velhas Basin, Minas Gerais State, Brazil. INAA was applied using the TRIGA Mark I IPR - R1 reactor at the Nuclear Technology Development Center of the National Committee of Nuclear Energy (CDTN/CNEN), in Belo Horizonte city, Minas Gerais State. At 100 kW of potency the flux of neutrons is 6.6 10{sup 11} n.cm{sup -2}.s{sup -1}. The samples analyzed were: water; sediment; gravel of gold mine and forage. The obtained results for the Das Velhas Basin in water and sediment samples - mining companies region - show a high level ({mu}g/g) of contamination with the analyzed elements, mainly in the sediment samples. During the period of floods, in farming region hundreds of kilometers away, contamination is found in fish and forage, reaching and harming both people and animals that live in the marginal region. (Author)

  14. Neutron activation analysis of ceramic tiles and its component and radon exhalation rate.

    Science.gov (United States)

    El-Shershaby, A; Sroor, A; Ahmed, F; Abdel-Haleem, A S; Abdel, Z

    2004-01-01

    The concentrations of 20 trace elements in several ceramics tiles and ceramic composites used in Egypt were elementally analyzed by neutron activation analysis(NAA) technique. The samples and standard were irradiated with reactor for 4 h (in the Second Research Egyptian Reactor(Et-RR-2)) with thermal neutron flux 5.9 x 10(13) n/(cm2 x s). The gamma-ray spectra obtained were measured for several times by means of the hyper pure germanium detection system(HPGe). Also a solid state nuclear track detector(SSNTD) CR-39, was used to measure the emanation rate of radon for these samples. The radium concentrations were found to vary from 0.39-3.59 ppm and the emanation rates were found to vary from (0.728-5.688) x 10(-4) kg/(m2 x s). The elemental analysis of the ceramic tiles and ceramic composites have a great importance in assigning the physical properties and in turn the quality of the material.

  15. Polymeric microspheres for radionuclide synovectomy containing neutron-activated holmium-166.

    Science.gov (United States)

    Mumper, R J; Mills, B J; Ryo, U Y; Jay, M

    1992-03-01

    Poly-L-lactic acid (PLA) microspheres containing neutron-activated 166Ho were investigated as potential agents for radionuclide synovectomy. Stable 165Ho, complexed to acetylacetone (AcAc), was incorporated into PLA spheres by the solvent evaporation technique. Spheres prepared with the optimal mean particle size of 7.2 microns (range 2-13 microns) containing 25.4% 165Ho-AcAc (9.1% 165Ho) were irradiated in a high neutron flux to produce 31.1-36.0 mCi 166Ho. In vitro human plasma studies showed that the irradiated spheres retained 99.0 +/- 0.01% of the 166Ho at 314 hr. In-vivo retention studies were conducted by administering irradiated PLA spheres with 257-591 microCi 166Ho into the joint space of normal rabbits (n = 6). Biodistribution analysis and gamma camera analysis showed 166Ho retention in the joint space after 120 hr of 97.7% +/- 0.8% and 98.2% +/- 2.4%, respectively, with no uptake by the lymph nodes. The ease with which the PLA spheres can be made in the optimal size range for later irradiation and their ability to retain the 166Ho make them attractive agents for radionuclide synovectomy.

  16. Comparison of IUPAC k0 Values and Neutron Cross Sections to Determine a Self-consistent Set of Data for Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, Richard B; Revay, Zsolt

    2009-12-01

    Independent databases of nuclear constants for Neutron Activation Analysis (NAA) have been independently maintained by the physics and chemistry communities for many year. They contain thermal neturon cross sections s0, standardization values k0, and transition probabilities Pg. Chemistry databases tend to rely upon direct measurements of the nuclear constants k0 and Pg which are often published in chemistry journals while the physics databases typically include evaluated s0 and Pg data from a variety of experiments published mainly in physics journals. The IAEA/LBNL Evaluated Gamma-ray Activation File (EGAF) also contains prompt and delayed g-ray cross sections sg from Prompt Gamma-ray Activation Analysis (PGAA) measurements that can also be used to determine k0 and s0 values. As a result several independent databases of fundamental constants for NAA have evolved containing slightly different and sometimes discrepant results. An IAEA CRP for a Reference Database for Neutron Activation Analysis was established to compare these databases and investigate the possibilitiy of producing a self-consistent set of s0, k0, sg, and Pg values for NAA and other applications. Preliminary results of this IAEA CRP comparison are given in this paper.

  17. In-plane shear piezoelectric wafer active sensor phased arrays for structural health monitoring

    Science.gov (United States)

    Wang, Wentao; Zhou, Wensong; Wang, Peng; Wang, Chonghe; Li, Hui

    2016-04-01

    This paper proposes a new way for guided wave structural health monitoring using in-plane shear (d36 type) piezoelectric wafer active sensors phased arrays. Conventional piezoelectric wafer active sensors phased arrays based on inducing into specific Lamb wave modes (d31 type) has already widely used for health monitoring of the thin-wall structures. Rather than Lamb wave modes, the in-plane shear piezoelectric wafer active sensors phased arrays induces in-plane shear horizontal (SH) guided waves. The SH guided waves are distinct with the Lamb waves with simple waveform and less additional converted wave modes and the zero symmetric mode (SH0) is non-dispersive. In this paper, the advantage of the shear horizontal wave and the in-plane shear piezoelectric wafers capability to generate SH waves is first reviewed. Then finite element analysis of a 4-in-plane shear wafer active sensors phased array embedded on a rectangular aluminium plate is performed. In addition, numerical simulations with respect to creaks with different sizes as well as locations are implemented by the in-plane shear wafer active sensors phased array. For comparison purposes, the same numerical simulations using the conventional piezoelectric wafer active sensors phased arrays are also employed at the same time. Results indicate that the in-plane shear (d36 type) piezoelectric wafer active sensors phased arrays has the potential to identify damage location and assess damage severity in structural health monitoring.

  18. Activation of soil and chemical reagents exposed to the neutrons released by the JCO criticality accident in Tokai-mura.

    Science.gov (United States)

    Murata, Y; Muroyama, T; Kawabata, Y; Yamamoto, M; Komura, K

    2001-09-01

    Specific activities (Bq/g-element) of residual neutron-induced radionuclides by the JCO criticality accident were measured for soil, concrete block and chemical reagent samples collected in the JCO campus. Induced radionuclides such as 24Na, 46Sc, 54Mn, 59Fe, 60Co, 65Zn, 82Br, 122Sb, 134Cs and 140La were detected in the samples, depending on the ground distance from the accident point and the sampling date. Apparent thermal, epi-thermal and fast neutron fluences, which reached the sample at each point, were roughly estimated from the specific activities and cross sections of the target nuclides taken from a literature. The present data are believed to be important as validation data for a three-dimensional neutron transport model calculation.

  19. Use of Instrumental Neutron Activation Analysis to investigate the distribution of trace elements among subsamples of solid materials

    CERN Document Server

    DAgostino, Giancarlo; Giordani, Laura; Oddone, Massimo; Kipphardt, Heinrich; Richter, Silke

    2013-01-01

    The results of analytical measurements performed with solid-sampling techniques are affected by the distribution of the analytes within the matrix. The effect becomes significant in case of determination of trace elements in small subsamples. In this framework we propose a measurement model based on Instrumental Neutron Activation Analysis to determine the relative variability of the amount of an analyte among subsamples of a material. The measurement uncertainty is evaluated and includes the counting statistics, the full-energy gamma peak efficiency and the spatial gradient of the neutron flux at the irradiation position. The data we obtained in a neutron activation experiment and showing the relative variability of As, Au, Ir, Sb and W among subsamples of a highly pure Rh foil are also presented.

  20. Prospects of steady state magnetic diagnostic of fusion reactors based on metallic Hall sensors

    Science.gov (United States)

    Ďuran, I.; Sentkerestiová, J.; Kovařík, K.; Viererbl, L.

    2012-06-01

    Employment of sensors based on Hall effect (Hall sensors) is one of the candidate approaches to detection of almost steady state magnetic fields in future fusion reactors based on magnetic confinement (tokamaks, stellarators etc.), and also in possible fusion-fission hybrid systems having these fusion reactors as a neutron source and driver. This contribution reviews the initial considerations concerning application of metallic Hall sensors in fusion reactor harsh environment that include high neutron loads (>1018 cm-2) and elevated temperatures (>200°C). In particular, the candidate sensing materials, candidate technologies for sensors production, initial analysis of activation and transmutation of sensors under reactor relevant neutron loads and the tests of the the first samples of copper Hall sensors are presented.

  1. Metal-Organic Frameworks as Active Materials in Electronic Sensor Devices.

    Science.gov (United States)

    Campbell, Michael G; Dincă, Mircea

    2017-05-12

    In the past decade, advances in electrically conductive metal-organic frameworks (MOFs) and MOF-based electronic devices have created new opportunities for the development of next-generation sensors. Here we review this rapidly-growing field, with a focus on the different types of device configurations that have allowed for the use of MOFs as active components of electronic sensor devices.

  2. Radiation Tolerance of CMOS Monolithic Active Pixel Sensors with Self-Biased Pixels

    CERN Document Server

    Deveaux, M; Besson, A; Claus, G; Colledani, C; Dorokhov, M; Dritsa, C; Dulinski, W; Fröhlich, I; Goffe, M; Grandjean, D; Heini, S; Himmi, A; Hu, C; Jaaskelainen, K; Müntz, C; Shabetai, A; Stroth, J; Szelezniak, M; Valin, I; Winter, M

    2009-01-01

    CMOS Monolithic Active Pixel Sensors (MAPS) are proposed as a technology for various vertex detectors in nuclear and particle physics. We discuss the mechanisms of ionizing radiation damage on MAPS hosting the the dead time free, so-called self bias pixel. Moreover, we discuss radiation hardened sensor designs which allow operating detectors after exposing them to irradiation doses above 1 Mrad

  3. MIMU-Wear: ontology-based sensor selection for real-world wearable activity recognition

    NARCIS (Netherlands)

    Villalonga, Claudia; Pomares, Hector; Rojas, Ignacio; Banos Legran, Oresti

    2017-01-01

    An enormous effort has been made during the recent years towards the recognition of human activity based on wearable sensors. Despite the wide variety of proposed systems, most existing solutions have in common to solely operate on predefined settings and constrained sensor setups. Real-world

  4. ANDI-03: a genetic algorithm tool for the analysis of activation detector data to unfold high-energy neutron spectra.

    Science.gov (United States)

    Mukherjee, Bhaskar

    2004-01-01

    The thresholds of (n,xn) reactions in various activation detectors are commonly used to unfold the neutron spectra covering a broad energy span, i.e. from thermal to several hundreds of MeV. The saturation activities of the daughter nuclides (i.e. reaction products) serve as the input data of specific spectra unfolding codes, such as SAND-II and LOUHI-83. However, most spectra unfolding codes, including the above, require an a priori (guess) spectrum to starting up the unfolding procedure of an unknown spectrum. The accuracy and exactness of the resulting spectrum primarily depends on the subjectively chosen guess spectrum. On the other hand, the Genetic Algorithm (GA)-based spectra unfolding technique ANDI-03 (Activation-detector Neutron DIfferentiation) presented in this report does not require a specific starting parameter. The GA is a robust problem-solving tool, which emulates the Darwinian Theory of Evolution prevailing in the realm of biological world and is ideally suited to optimise complex objective functions globally in a large multidimensional solution space. The activation data of the 27Al(n,alpha)24Na, 116In(n,gamma)116mIn, 12C(n,2n)11C and 209Bi(n,xn)(210-x)Bi reactions recorded at the high-energy neutron field of the ISIS Spallation source (Rutherford Appleton Laboratory, UK) was obtained from literature and by applying the ANDI-03 GA tool, these data were used to unfold the neutron spectra. The total neutron fluence derived from the neutron spectrum unfolded using GA technique (ANDI-03) agreed within +/-6.9% (at shield top level) and +/-27.2% (behind a 60 cm thick concrete shield) with the same unfolded with the SAND-II code.

  5. Neutron detection apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Derzon, Mark S.; Borek, III, Theodore T.

    2017-08-15

    An apparatus for neutron detection is provided. The apparatus comprises a sensor medium in electrical contact with an electrode arrangement conformed to collect radiation-generated charge from the sensor medium. The sensor medium comprises a borazine and/or a borazine-based polymer.

  6. Investigation of therapeutic potentials of some selected medicinal plants using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Abubakar, Sani; Isa, Nasiru Fage [Bayero University, Kano Nigeria (Nigeria); Usman, Ahmed Rufa’i [University of Malaya, Kuala Lumpur (Malaysia); Umaru Musa Yar’adua University, Katsina Nigeria (Nigeria); Khandaker, Mayeen Uddin [University of Malaya, Kuala Lumpur (Malaysia); Abubakar, Nuraddeen [Center for Energy Research and Training, Ahmadu Bello University, Zaria Nigeria (Nigeria)

    2015-04-24

    Series of attempts were made to investigate concentrations of trace elements and their therapeutic properties in various medicinal plants. In this study, samples of some commonly used plants were collected from Bauchi State, Nigeria. They includes leaves of azadirachta indica (neem), Moringa Oleifera (moringa), jatropha curcas (purgin Nut), guiera senegalensis (custard apple) and anogeissus leiocarpus (African birch). These samples were analyzed for their trace elements contents with both short and long irradiation protocols of Instrumental Neutron Activation Analysis (INAA) at Nigerian Research Reactor-1 (NIRR-1) of Ahmadu Bello University, Zaria, Nigeria. The level of trace elements found varies from one sample to another, with some reported at hundreds of mg/Kg dry weight. The results have been compared with the available literature data. The presence of these trace elements indicates promising potentials of these plants for relief of certain ailments.

  7. The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)

    Energy Technology Data Exchange (ETDEWEB)

    Pinault, Jean-Louis [IAEA Expert, 96 rue du Port David, 45370 Dry (France)], E-mail: jeanlouis_pinault@hotmail.fr; Solis, Jose [Instituto Peruano de Energia Nuclear, Av. Canada No. 1470, San Borja, Lima 41 (Peru)

    2009-04-15

    The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole logging and on-line analysis on conveyor belt of raw materials.

  8. Application of neutron activation in hydrometallurgical process of lead chloride extraction from boulangerit

    Directory of Open Access Journals (Sweden)

    Zovko Emira

    2010-01-01

    Full Text Available In this work, a neutron activation analysis for the identification of radiochemical elements in the ore concentrate of zone Vareš, Bosnia and Hercegovina, has been applied. The possibility of dissolving ore concentrate from iron(III chloride was examined. To follow the dissolving lead (II sulphide yield from the ore concentrates, in addition to radioisotope labeling process, it is necessary to use a gravimetric analysis of the extracted lead(II chloride. Based on kinetic measurements of dissolving concentrate efficiency it was observed that the optimum dissolving time was about 2 to 3 h, and that the one-time procedure can dissolve about 72±5% of marked components.

  9. The accuracy of instrumental neutron activation analysis of kilogram-size inhomogeneous samples.

    Science.gov (United States)

    Blaauw, M; Lakmaker, O; van Aller, P

    1997-07-01

    The feasibility of quantitative instrumental neutron activation analysis (INAA) of samples in the kilogram range without internal standardization has been demonstrated by Overwater et al. (Anal. Chem. 1996, 68, 341). In their studies, however, they demonstrated only the agreement between the "corrected" γ ray spectrum of homogeneous large samples and that of small samples of the same material. In this paper, the k(0) calibration of the IRI facilities for large samples is described, and, this time in terms of (trace) element concentrations, some of Overwater's results for homogeneous materials are presented again, as well as results obtained from inhomogeneous materials and subsamples thereof. It is concluded that large-sample INAA can be as accurate as ordinary INAA, even when applied to inhomogeneous materials.

  10. Instrumental neutron activation analysis of an enriched 28Si single-crystal

    CERN Document Server

    DAgostino, G; Giordani, L; Mana, G; Oddone, M

    2013-01-01

    The determination of the Avogadro constant plays a key role in the redefinition of the kilogram in terms of a fundamental constant. The present experiment makes use of a silicon single-crystal highly enriched in 28Si that must have a total impurity mass fraction smaller than a few parts in 109. To verify this requirement, we previously developed a relative analytical method based on neutron activation for the elemental characterization of a sample of the precursor natural silicon crystal WASO 04. The method is now extended to fifty-nine elements and applied to a monoisotopic 28Si single-crystal that was grown to test the achievable enrichment. Since this crystal was likely contaminated, this measurement tested also the detection capabilities of the analysis. The results quantified contaminations by Ge, Ga, As, Tm, Lu, Ta, W and Ir and, for a number of the detectable elements, demonstrated that we can already reach the targeted 1 ng/g detection limit.

  11. Development of distinction method of production area of ginsengs by using a neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Youngjin; Chung, Yongsam; Sim, Chulmuu; Sun, Gwangmin; Lee, Yuna; Yoo, Sangho

    2011-01-15

    During the last 2 years of the project, we have tried to develop the technology to make a distinction of the production areas for Korean ginsengs cultivated in the various provinces in Korea and foreign countries. It will contribute to secure the health food safety for public and stability of its market. In this year, we collected ginseng samples cultivated in the northeastern province in Chinese mainland such as Liaoning province, Jilin province and Baekdu mountain within Jilin province. 10 ginseng samples were collected at each province. The elemental concentrations in the ginseng were analyzed by using a neutron activation analysis technique at the HANARO research reactor. The distinction of production area was made by using a statistical software. As a result, the Chinese Korean ginsengs were certainly differentiated from those cultivated in the famous province in Korea though there was a limitation that the number of our sample we analyzed is very small.

  12. Neutron Activation Analysis of the Rare Earth Elements (REE) - With Emphasis on Geological Materials

    Science.gov (United States)

    Stosch, Heinz-Günter

    2016-08-01

    Neutron activation analysis (NAA) has been the analytical method of choice for rare earth element (REE) analysis from the early 1960s through the 1980s. At that time, irradiation facilitieswere widely available and fairly easily accessible. The development of high-resolution gamma-ray detectors in the mid-1960s eliminated, formany applications, the need for chemical separation of the REE from the matrix material, making NAA a reliable and effective analytical tool. While not as precise as isotopedilution mass spectrometry, NAA was competitive by being sensitive for the analysis of about half of the rare earths (La, Ce, Nd, Sm, Eu, Tb, Yb, Lu). The development of inductively coupled plasma mass spectrometry since the 1980s, together with decommissioning of research reactors and the lack of installation of new ones in Europe and North America has led to the rapid decline of NAA.

  13. Neutron activation analysis of ceramic tiles and its component and radon exhalation rate

    Institute of Scientific and Technical Information of China (English)

    A. El-Shershaby; A. Sroor; F. Ahmed; A.S. Abdel-Haleem; Z. Abdel

    2004-01-01

    The concentrations of 20 trace elements in several ceramics tiles and ceramic composites used in Egypt were elementally analyzed by neutron activation analysis(NAA) technique. The samples and standard were irradiated with reactor for 4 h( in the Second The gamma-ray spectra obtained were measured for several times by means of the hyper pure germanium detection system( HPGe).Also a solid state nuclear track detector(SSNTD) CR-39, was used to measure the emanation rate of radon for these samples. The radium concentrations were found to vary from 0.39-3.59 ppm and the emanation rates were found to vary from (0.728-5.688) x 10-4The elemental analysis of the ceramic tiles and ceramic composites have a great importance in assigning the physical properties and in turn the quality of the material.

  14. Environmental variation of arsenic levels in human blood determined by neutron activation analysis

    DEFF Research Database (Denmark)

    Heydorn, Kaj

    1970-01-01

    Arsenic levels in blood plasma and red cells from patients with Blackfoot disease, a peripheral arteriosclerosis endemic to a small area in Taiwan, were studied in relation to healthy individuals from the same and other parts of Taiwan and compared with arsenic levels in a control group from...... Denmark. Arsenic was determined by neutron activation analysis with radiochemical separation and re-irradiation yield determination. The precision and accuracy of the results have been carefully evaluated in order to permit quantitative tests for the significance of the observed differences. The results...... from Taiwan followed a logarithmic normal distribution, and no difference was found between Blackfoot patients and their healthy family members. However, their overall arsenic levels were higher than the Taiwan average, presumably because of arsenic in their drinking water. Much lower levels were found...

  15. Determination of Mineral Contents in Unpolished Rice and Bean Samples by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moon, J. H.; Kim, S. H.; Baek, S. Y.; Chung, Y. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    As scientists have focused their researches on the health impacts caused by mineral nutrient deficiencies and hazardous elements, public concern regarding mineral intake from dietary food is rising. In this reason, the dietary habits of Koreans have been shifted from white rice to more nutrient rice like unpolished rice and rice mixed with beans. It is known that unpolished rice and beans contain more protein, vitamin and mineral contents than white rice and are more beneficial to human health, even though they sometimes cause indigestion or allergy. The objectives of this study were to determine the mineral contents in unpolished rice and bean samples by a neutron activation analysis (NAA) and to compare the level of mineral contents between the samples

  16. Microcomputer-based pneumatic controller for neutron activation analysis. [For analyzing uranium ore samples

    Energy Technology Data Exchange (ETDEWEB)

    Byrd, J.S.; Sand, R.J.

    1976-10-01

    A microcomputer-based pneumatic controller for neutron activation analysis was designed and built at the Savannah River Laboratory for analysis of large numbers of geologic samples for locating potential supplies of uranium ore for the National Uranium Resource Evaluation program. In this system, commercially available microcomputer logic modules are used to transport sample capsules through a network of pressurized air lines. The logic modules are interfaced to pneumatic valves, solenoids, and photo-optical detectors. The system operates from programs stored in firmware (permanent software). It also commands a minicomputer and a hard-wired pulse height analyzer for data collection and bookkeeping tasks. The advantage of the system is that major system changes can be implemented in the firmware with no hardware changes. This report describes the hardware, firmware, and software for the electronics system.

  17. Neutron activation analysis for assessing the concentrations of trace elements in laboratory detergents

    Energy Technology Data Exchange (ETDEWEB)

    Iskander, F.Y.

    1986-01-01

    Nondestructive instrumental neutron activation analysis was used to assess the concentration of 20 elements in the following laboratory detergents: Micro, Cavi-Clean liquid, RBS-35, Liqui-Nox, Treg-A-Zyme, Alcojet, Alconox, Alcotabs and Radiacwash: and a detergent additive: CaviClean additive. The upper detected limits or the concentration ranges for the detergents are (element concentration in ..mu..g/g): Ba, <20; Ce, <0.8; Cl, 27-10000; Co, <0.1; Cr, <1; Cs, <0.6; Eu, <0.009; Fe, <3-45; Hf, <0.07; Mn, <10; Ni, <5; Rb, <0.08-0.89; Sb, <0.006-1.8; Sc, <0.0003-0.008; Se, <0.05; Sr <30; Th, <0.6; U, <0.1; V, <10; Zn, <0.2-2.0. The concentrations of trace elements in the examined laboratory detergents are below those reported in the literature for household detergents.

  18. Chemical contents in Lygeum spartum L. using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nedjimi, Bouzid [Djelfa Univ. (Algeria). Lab. of Exploration and Valorization of Steppe Ecosystem; Beladel, Brahim [Djelfa Univ. (Algeria)

    2015-09-01

    The present investigation was conducted to determine the chemical contents of Lygeum spartum L. (Poaceae). Samples were analyzed in order to determine essential (Ca, K, Na, Fe, Co) and some potentially toxic elements (Eu, Sb, Tb) using instrumental neutron activation analysis (INAA). In general chemical element contents were in substantial amounts to meet adult sheep requirements. Potential intake of Ca, K, Zn, Co and Fe by ruminant weighing 50 kg BW consuming 2.0 kg per day DM was sufficient to satisfy their requirements. However, only Na level was still insufficient to meet the requirements for grazing ruminants. Potential toxic elements in this species were within the safety baseline of all the assayed elements recommended by NRC. Na supplementation would seem to be necessary in this zone, for optimum productivity of grazing animals.

  19. Investigation of therapeutic potentials of some selected medicinal plants using neutron activation analysis

    Science.gov (United States)

    Abubakar, Sani; Usman, Ahmed Rufa'i.; Isa, Nasiru Fage; Khandaker, Mayeen Uddin; Abubakar, Nuraddeen

    2015-04-01

    Series of attempts were made to investigate concentrations of trace elements and their therapeutic properties in various medicinal plants. In this study, samples of some commonly used plants were collected from Bauchi State, Nigeria. They includes leaves of azadirachta indica (neem), Moringa Oleifera (moringa), jatropha curcas (purgin Nut), guiera senegalensis (custard apple) and anogeissus leiocarpus (African birch). These samples were analyzed for their trace elements contents with both short and long irradiation protocols of Instrumental Neutron Activation Analysis (INAA) at Nigerian Research Reactor-1 (NIRR-1) of Ahmadu Bello University, Zaria, Nigeria. The level of trace elements found varies from one sample to another, with some reported at hundreds of mg/Kg dry weight. The results have been compared with the available literature data. The presence of these trace elements indicates promising potentials of these plants for relief of certain ailments.

  20. Hybrid combination of multi-layer perceptron and neutron activation analysis in cement prediction

    Science.gov (United States)

    Eftekhari-Zadeh, E.; Feghhi, S. A. H.; Roshani, G. H.

    2017-02-01

    Determination of concentration of major elements such as Ca, Si, Al, and Fe in cement is very important for quality control during its production, correct classification according to the existing standards, and thus for appropriate use in the construction industry. For this purpose, neutron activation analysis is very suitable. In this preliminary theoretical work, the irradiation and consecutive measurement of the percentage of the constituent elements in different cement samples were done using MCNPX with γ-ray spectra as the output. Specific peaks of Ca, Si, Al, and Fe obtained from these spectra were used as input for artificial neural network (18 of them for training and 8 for testing) resulting in the determination of each element in the given sample. The mean absolute errors of the results are less than 0.4%, which is very promising for the future experimental work where the uncertainties are usually one order higher.

  1. Determination of Total Arsenic in Seaweed Products by Neutron Activation Analysis

    Directory of Open Access Journals (Sweden)

    N. Salim

    2013-04-01

    Full Text Available Seaweed products are widely consumed as food nowadays. Seaweeds are known to contain arsenic due to their capability to accumulate arsenic from the environment. Arsenic is a known toxic element which naturally occurs in the environment. Ingestion of high levels of arsenic will cause several adverse health effects. Arsenic in food occurs at trace concentrations which require sensitive and selective analysis methods to perform elemental analysis on. Validated neutron activation analysis was used to determine the arsenic contents in seaweed products namely catoni from domestic product and nori from foreign products. The total arsenic concentration in the samples analyzed ranges from 0.79 mg/kg to 30.14 mg/kg with mean concentration 14.39 mg/kg. The estimated exposure to arsenic contributed by the analyzed products is from 0.07% up to 8.54% of the established provisional tolerable daily intake (PTDI which is still far below the maximum tolerable level

  2. Multi-elemental profile of some Brazilian make-up products by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dalmazio, Ilza; Menezes, Maria Angela de B.C., E-mail: id@cdtn.b, E-mail: menezes@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Reator e Tecnicas Analiticas. Lab. de Ativacao Neutronica

    2011-07-01

    Recent works have shown that analysis in cosmetics and beauty products from the European and Asian markets indicate the presence of U, Th and rare earths besides other trace elements. Considering these previous findings and health issues, it would be valuable to obtain information on elements in cosmetics available in the Brazilian market. The purpose of this study was to acquire a multi-elemental profile of some Brazilian make-up products of diverse brands. Samples of eye shadow, liquid base, facial concealer, lipstick, and compact face powder were analyzed applying neutron activation analysis, k{sub 0}-standardization method at CDTN/CNEN, using the TRIGA Mark I IPR-R1 research reactor. Concentrations of more than 30 elements in samples are presented and it was found elements included in Brazilian National Health Surveillance Agency prohibitive list, rare earths, Th and U in a minimum of two cosmetic samples. (author)

  3. Multi-elemental profile of some Brazilian make-up products by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dalmazio, Ilza; Menezes, Maria Angela de B.C., E-mail: id@cdtn.b, E-mail: menezes@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Reator e Tecnicas Analiticas. Lab. de Ativacao Neutronica

    2011-07-01

    Recent works have shown that analysis in cosmetics and beauty products from the European and Asian markets indicate the presence of U, Th and rare earths besides other trace elements. Considering these previous findings and health issues, it would be valuable to obtain information on elements in cosmetics available in the Brazilian market. The purpose of this study was to acquire a multi-elemental profile of some Brazilian make-up products of diverse brands. Samples of eye shadow, liquid base, facial concealer, lipstick, and compact face powder were analyzed applying neutron activation analysis, k{sub 0}-standardization method at CDTN/CNEN, using the TRIGA Mark I IPR-R1 research reactor. Concentrations of more than 30 elements in samples are presented and it was found elements included in Brazilian National Health Surveillance Agency prohibitive list, rare earths, Th and U in a minimum of two cosmetic samples. (author)

  4. Development of Neutron Activation Analysis for Scientific Interpretation on Cultural Properties

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyu Ho; Kim, Na Young; Ko, Min Chung; Kim, Min Ji; Cho, Su Mi; Kang, Ji Eun [Kongju National University, Gongju (Korea, Republic of)

    2010-05-15

    This research is tried to set up the application of neutron activation analysis and to evaluate the historical information about ceramics materials at production kilns for the standardized technology of NAA. This project is measured the 112 samples from Jijong-dong, Daejeon and 4 production kiln sites in Kyongsangdo by using NAA and XRF and classified as types and production site by PCA and applied of factor analysis, discruminant analysis and cluster analysis. As the results, we know that it is classified as pottery and roof tile as measured 11 elements and that it is not classified major and trace elements as the production kiln sites because raw materials is 2nd clay. At last, it is investigated the comparative evaluation of raw material as production kiln sites by cluster analysis as the basis of the data of NA

  5. Hybrid combination of multi-layer perceptron and neutron activation analysis in cement prediction

    Indian Academy of Sciences (India)

    E EFTEKHARI-ZADEH; S A H FEGHHI; G H ROSHANI

    2017-02-01

    Determination of concentration of major elements such as Ca, Si, Al, and Fe in cement is very important for quality control during its production, correct classification according to the existing standards, and thus for appropriate use in the construction industry. For this purpose, neutron activation analysis is verysuitable. In this preliminary theoretical work, the irradiation and consecutive measurement of the percentage of the constituent elements in different cement samples were done using MCNPX with γ -ray spectra as the output. Specific peaks of Ca, Si, Al, and Fe obtained from these spectra were used as input for artificial neural network (18 of them for training and 8 for testing) resulting in the determination of each element in the given sample. The mean absolute errors of the results are less than 0.4%, which is very promising for the future xperimental work where the uncertainties are usually one order higher.

  6. Elemental characterization of the Avogadro silicon crystal WASO 04 by neutron activation analysis

    CERN Document Server

    D'Agostino, Giancarlo; Giordani, Laura; Mana, Giovanni; Massa, Enrico; Oddone, Massimo; 10.1088/0026-1394/49/6/696

    2013-01-01

    Analytical measurements of the 28Si crystal used for the determination of the Avogadro constant are essential to prevent biased results or under-estimated uncertainties. A review of the existing data confirms the high-purity of silicon with respect to a large number of elements. In order to obtain a direct evidence of purity, we developed a relative analytical method based on neutron activation. As a preliminary test, this method was applied to a sample of the Avogadro crystal WASO 04. The investigation concerned twenty-nine elements. The mass fraction of Au was quantified to be 1.03(18) x 10-12. For the remaining twenty-eight elements, the mass fractions are below the detection limits, which range between 1 x 10-12 and 1 x 10-5.

  7. Application of instrumental neutron activation analysis for the examination of oil pigments

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y.S.; Kim, S.H.; Sun, G.M.; Lim, J.M.; Moon, J.H.; Kim, Y.J. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lim, S.J.; Song, Y.N.; Kim, K. [National Museum of Contemporary Art, Gwacheon, Gyeonggi-do (Korea, Republic of)

    2011-07-01

    This study is to investigate the applicability of instrumental neutron activation analysis (INAA) as a non-destructive examination tool for the quantitative chemical composition analysis associated with authentication, restoration and conservation of art objects in the field of cultural heritage. The quantitative analysis of major, minor and trace elements in Rembrandt's {sup registered} oil pigments recently collected at the Korean market as one of the art objects was carried out using INAA facilities of the HANARO research reactor at the Korea Atomic Energy Research Institute in collaboration with the National Museum of Contemporary Art in Korea. Analytical quality control was implemented using NIST SRM 2709, certified reference materials and metal standards. The analytical results for seventeen characteristic elements of thirty-one measured elements were statistically treated to identify the characteristic correlations and patterns between color and source of oil pigment and similarity degree of constituents using a cluster and discriminate analysis. (orig.)

  8. Instrumental neutron activation analysis data for cloud-water particulate samples, Mount Bamboo, Taiwan

    Science.gov (United States)

    Lin, Neng-Huei; Sheu, Guey-Rong; Wetherbee, Gregory A.; Debey, Timothy M.

    2013-01-01

    Cloud water was sampled on Mount Bamboo in northern Taiwan during March 22-24, 2002. Cloud-water samples were filtered using 0.45-micron filters to remove particulate material from the water samples. Filtered particulates were analyzed by instrumental neutron activation analysis (INAA) at the U.S. Geological Survey National Reactor Facility in Denver, Colorado, in February 2012. INAA elemental composition data for the particulate materials are presented. These data complement analyses of the aqueous portion of the cloud-water samples, which were performed earlier by the Department of Atmospheric Sciences, National Central University, Taiwan. The data are intended for evaluation of atmospheric transport processes and air-pollution sources in Southeast Asia.

  9. ESAM: Endocrine inspired Sensor Activation Mechanism for multi-target tracking in WSNs

    Science.gov (United States)

    Adil Mahdi, Omar; Wahab, Ainuddin Wahid Abdul; Idris, Mohd Yamani Idna; Znaid, Ammar Abu; Khan, Suleman; Al-Mayouf, Yusor Rafid Bahar

    2016-10-01

    Target tracking is a significant application of wireless sensor networks (WSNs) in which deployment of self-organizing and energy efficient algorithms is required. The tracking accuracy increases as more sensor nodes are activated around the target but more energy is consumed. Thus, in this study, we focus on limiting the number of sensors by forming an ad-hoc network that operates autonomously. This will reduce the energy consumption and prolong the sensor network lifetime. In this paper, we propose a fully distributed algorithm, an Endocrine inspired Sensor Activation Mechanism for multi target-tracking (ESAM) which reflecting the properties of real life sensor activation system based on the information circulating principle in the endocrine system of the human body. Sensor nodes in our network are secreting different hormones according to certain rules. The hormone level enables the nodes to regulate an efficient sleep and wake up cycle of nodes to reduce the energy consumption. It is evident from the simulation results that the proposed ESAM in autonomous sensor network exhibits a stable performance without the need of commands from a central controller. Moreover, the proposed ESAM generates more efficient and persistent results as compared to other algorithms for tracking an invading object.

  10. Carbon Nanotubes as Active Components for Gas Sensors

    Directory of Open Access Journals (Sweden)

    Wei-De Zhang

    2009-01-01

    Full Text Available The unique structure of carbon nanotubes endows them with fantastic physical and chemical characteristics. Carbon nanotubes have been widely studied due to their potential applications in many fields including conductive and high-strength composites, energy storage and energy conversion devices, sensors, field emission displays and radiation sources, hydrogen storage media, and nanometer-sized semiconductor devices, probes, and quantum wires. Some of these applications have been realized in products, while others show great potentials. The development of carbon nanotubes-based sensors has attracted intensive interest in the last several years because of their excellent sensing properties such as high selectivity and prompt response. Carbon nanotube-based gas sensors are summarized in this paper. Sensors based on single-walled, multiwalled, and well-aligned carbon nanotubes arrays are introduced. Modification of carbon nanotubes with functional groups, metals, oxides, polymers, or doping carbon nanotubes with other elements to enhance the response and selectivity of the sensors is also discussed.

  11. A Novel Wearable Sensor-Based Human Activity Recognition Approach Using Artificial Hydrocarbon Networks.

    Science.gov (United States)

    Ponce, Hiram; Martínez-Villaseñor, María de Lourdes; Miralles-Pechuán, Luis

    2016-07-05

    Human activity recognition has gained more interest in several research communities given that understanding user activities and behavior helps to deliver proactive and personalized services. There are many examples of health systems improved by human activity recognition. Nevertheless, the human activity recognition classification process is not an easy task. Different types of noise in wearable sensors data frequently hamper the human activity recognition classification process. In order to develop a successful activity recognition system, it is necessary to use stable and robust machine learning techniques capable of dealing with noisy data. In this paper, we presented the artificial hydrocarbon networks (AHN) technique to the human activity recognition community. Our artificial hydrocarbon networks novel approach is suitable for physical activity recognition, noise tolerance of corrupted data sensors and robust in terms of different issues on data sensors. We proved that the AHN classifier is very competitive for physical activity recognition and is very robust in comparison with other well-known machine learning methods.

  12. Neutron activation analysis of cadmium bioremediation by yeast isolated from the fermentation of cachaca

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Frederico H.; Moreira, Luciana M.C.; Porto, Barbara A.A.; Menezes, Maria Angela B.C.; Amaral, Angela M.; Neves, Maria J. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)], e-mail: fhr@cdtn.br; Rosa, Carlos A. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)], e-mail: carlrosa@icb.ufmg.br

    2009-07-01

    The accumulation of heavy metal in urban environment is a final result of industrial waste discharges. The removal and recovery of heavy metals from contaminated water and wastewater is important in the protection of the environment and human health. There are several chemical technologies used to remove heavy metals. Most of these are ineffective or excessively expensive when the metal concentrations are less than 100 mgL{sup -1}. Biological treatment with bioremediation, is an innovative technology available for heavy metal polluted wastewaters. Brazil has a big production of yeast as a by-product of the fermentation of sugar cane for the production of ethanol or, for the production of artisanal cachaca, notedly in the state of Minas Gerais. Biological organisms remove metals through of two processes: bioaccumulation and biosorption. This research used neutron activation technique to determine the capacity of 10 isolated yeast of the fermentation for the withdrawal of cadmium. The efflux of ions K{sup +}, was also analyzed by the same technique after the incorporation of cadmium by cells. This work showed that the neutron activation analysis is a suitable technique to quantification the metal absorbed from liquid solution and that isolated strains of the fermentation of cachaca are more efficient in removing cadmium of the liquid solution that the laboratorial strain. The influences of the metals on the growth of the cells are also observed. The results obtained were compared with the yeast strain of laboratory, Saccharomyces cerevisiae W303-WT. The tolerance of cadmium to concentration of 100 mgL{sup -1} was evaluated. (author)

  13. Innovative high pressure gas MEM's based neutron detector for ICF and active SNM detection.

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Shawn Bryan; Derzon, Mark Steven; Renzi, Ronald F.; Chandler, Gordon Andrew

    2007-12-01

    An innovative helium3 high pressure gas detection system, made possible by utilizing Sandia's expertise in Micro-electrical Mechanical fluidic systems, is proposed which appears to have many beneficial performance characteristics with regards to making these neutron measurements in the high bremsstrahlung and electrical noise environments found in High Energy Density Physics experiments and especially on the very high noise environment generated on the fast pulsed power experiments performed here at Sandia. This same system may dramatically improve active WMD and contraband detection as well when employed with ultrafast (10-50 ns) pulsed neutron sources.

  14. Assessment of the associated particle prompt gamma neutron activation technique for total body nitrogen measurement in vivo

    Science.gov (United States)

    Total Body Nitrogen (TBN) can be used to estimate Total Body Protein (TBP), an important body composition component at the molecular level. A system using the associated particle technique in conjunction with prompt gamma neutron activation analysis has been developed for the measurement of TBN in ...

  15. Neutron activation analysis and numerical taxonomy of thin orange ceramics from the manufacturing site of Rio Carnero, Puebla, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Rattray, E. (Universidad Nacional Autonoma de Mexico, Mexico City (Mexico). Inst. de Investigaciones Antropologicas); Harbottle, G. (Brookhaven National Lab., Upton, NY (USA))

    1991-04-01

    Examples of different types of Thin Orange ceramics found at the recently-discovered manufacturing sites in the state of Puebla have been analyzed by neutron activation. A full multivariate numerical analysis indicates that this material is chemically identical with the well-known Thin Orange of Teotihuacan.'' 33 refs., 2 figs., 2 tabs.

  16. The study of perpendicular magnetic anisotropy in the magnetic sensors with linear sensitivity using polarized neutron reflectometry

    Science.gov (United States)

    Zhu, T.

    2016-04-01

    The CoFeB sandwiched by Ta and MgO layers enables a perpendicular magnetic anisotropy (PMA) and provides a pathway for such application. In this paper, we reported the origin of PMA in CoFeB using the anomalous Hall effect (AHE) and polarized neutron reflectometry (PNR). From PNR experiments, we obtained the details of the magnetic and structural depth profiles inside the film. It is found that the PMA properties of CoFeB layers deposited above and under MgO layer are different and PNR measurements confirmed that a large PMA in the CoFeB above MgO layer is related to its low magnetization. Based on this PMA mechanism, we obtain a high sensitivity of AHE in the perpendicular CoFeB, which opens a new avenue to detect ultralow magnetic field.

  17. Neutrons in active proton therapy. Parameterization of dose and dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Uwe; Haelg, Roger A. [Univ. of Zurich (Switzerland). Dept. of Physics; Radiotherapy Hirslanden AG, Aarau (Switzerland); Lomax, Tony [Paul Scherrer Institute, Villigen (Switzerland). Center for Proton Therapy

    2017-08-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85 cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138 MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160 MeV or 177 MeV instead of 138 MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy.

  18. Parametric Evaluation of Active Neutron Interrogation for the Detection of Shielded Highly-Enriched Uranium in the Field

    Energy Technology Data Exchange (ETDEWEB)

    D. L. Chcihester; E. H. Seabury; S. J. Thompson; R. R. C. Clement

    2011-10-01

    Parametric studies using numerical simulations are being performed to assess the performance capabilities and limits of active neutron interrogation for detecting shielded highly enriched uranium (HEU). Varying the shield material, HEU mass, HEU depth inside the shield, and interrogating neutron source energy, the simulations account for both neutron and photon emission signatures from the HEU with resolution in both energy and time. The results are processed to represent different irradiation timing schemes and several different classes of radiation detectors, and evaluated using a statistical approach considering signal intensity over background. This paper describes the details of the modeling campaign and some preliminary results, weighing the strengths of alternative measurement approaches for the different irradiation scenarios.

  19. Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification.

    Science.gov (United States)

    Hamel, Michael C; Polack, J Kyle; Ruch, Marc L; Marcath, Matthew J; Clarke, Shaun D; Pozzi, Sara A

    2017-08-11

    The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to a possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.

  20. UHF wearable battery free sensor module for activity and falling detection.

    Science.gov (United States)

    Nam Trung Dang; Thang Viet Tran; Wan-Young Chung

    2016-08-01

    Falling is one of the most serious medical and social problems in aging population. Therefore taking care of the elderly by detecting activity and falling for preventing and mitigating the injuries caused by falls needs to be concerned. This study proposes a wearable, wireless, battery free ultra-high frequency (UHF) smart sensor tag module for falling and activity detection. The proposed tag is powered by UHF RF wave from reader and read by a standard UHF Electronic Product Code (EPC) Class-1 Generation-2 reader. The battery free sensor module could improve the wearability of the wireless device. The combination of accelerometer signal and received signal strength indication (RSSI) from a reader in the passive smart sensor tag detect the activity and falling of the elderly very successfully. The fabricated smart sensor tag module has an operating range of up to 2.5m and conducting in real-time activity and falling detection.