WorldWideScience

Sample records for network greatly impedes

  1. A-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Galigekere, Veda Prakash

    2016-01-01

    A novel A-source impedance network is proposed in this letter. The A-source impedance network uses an autotransformer for realizing converters for any application that demand a very high dc voltage gain. The network utilizes a minimal turns ratio compared to other Magnetically Coupled Impedance...... Source (MCIS) networks to attain a high voltage gain. In addition, the proposed converter draws a continuous current from the source, and hence it is suitable for many types of renewable energy sources. The derived network expressions and theoretical analysis are finally validated experimentally...... with an example single-switch 400 W dc-dc converter. For the closed-loop control design and stability assessment, a small signal model and its analysis of the proposed network are also presented in brief....

  2. Y-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    This letter introduces a new versatile Y-shaped impedance network for realizing converters that demand a very high-voltage gain, while using a small duty ratio. To achieve that, the proposed network uses a tightly coupled transformer with three windings, whose obtained gain is presently not matched...... by existing networks operated at the same duty ratio. The proposed impedance network also has more degrees of freedom for varying its gain, and hence, more design freedom for meeting requirements demanded from it. This capability has been demonstrated by mathematical derivation, and proven in experiment...

  3. Hybrid-Source Impedance Networks

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    Hybrid-source impedance networks have attracted attention among researchers because of their flexibility in performing buck-boost energy conversion. To date, three distinct types of impedance networks can be summarized for implementing voltage-type inverters with another three types summarized...... for current-type inverters. These impedance networks can in principle be combined into two generic network entities, before multiple of them can further be connected together by applying any of the two proposed generalized cascading concepts. The resulting two-level and three-level inverters implemented using...... the cascaded networks would have a higher output voltage gain and other unique advantages that currently have not been investigated yet. It is anticipated that these advantages would help the formed inverters find applications in photovoltaic and other renewable systems, where a high voltage gain is usually...

  4. Quadratic Boost A-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Chub, Andrii

    2016-01-01

    A novel quadratic boost A-source impedance network is proposed to realize converters that demand very high voltage gain. To satisfy the requirement, the network uses an autotransformer where the obtained gain is quadratically dependent on the duty ratio and is unmatched by any existing impedance ...

  5. Cascaded impedance networks for NPC inverter

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    Multilevel inverters are getting more and more attracted because they have better output waveform quality and lower semiconductor voltage stress. The Z-source NPC is a kind of single stage multilevel inverter which has the ability of voltage boost. But the boost capability is relatively low when...... they are subject to the renewable sources. To date, three distinct types of impedance networks can be summarized for implementing a hybrid source impedance network, which can in principle be combined and cascaded before connected to a NPC inverter by proposed two ways. The resulting cascaded impedance network NPC...... would have a higher output voltage gain. It is anticipated that it would help the formed inverters find applications in photovoltaic and other renewable systems, where a high voltage gain is usually requested. Experimental testing has already been conducted and verifies the theory....

  6. Two port network analysis for three impedance based oscillators

    KAUST Repository

    Said, Lobna A.

    2011-12-01

    Two-port network representations are applied to analyze complex networks which can be dissolved into sub-networks connected in series, parallel or cascade. In this paper, the concept of two-port network has been studied for oscillators. Three impedance oscillator based on two port concept has been analyzed using different impedance structures. The effect of each structure on the oscillation condition and the frequency of oscillation have been introduced. Two different implementations using MOS and BJT have been introduced. © 2011 IEEE.

  7. New Magnetically Coupled Impedance (Z-) Source Networks

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Loh, Poh Chiang

    2016-01-01

    by their discontinuous currents drawn from the sources and/or high stresses experienced by their components. This paper thus proposes three new MCIS networks named respectively as quasi-Y-source, quasi-Γ-Z-source and quasi-T-source or quasi-Trans-Z-source networks. These new networks inherit all advantages....... Derivations of all two-winding MCIS networks, including existing and new networks, from the generalized three-winding MCIS networks are then systematically illustrated, before comparing them. Operational principles, mathematical derivations, simulation and experimental results of all studied networks have...

  8. Theory of fractional order elements based impedance matching networks

    KAUST Repository

    Radwan, Ahmed G.

    2011-03-01

    Fractional order circuit elements (inductors and capacitors) based impedance matching networks are introduced for the first time. In comparison to the conventional integer based L-type matching networks, fractional matching networks are much simpler and versatile. Any complex load can be matched utilizing a single series fractional element, which generally requires two elements for matching in the conventional approach. It is shown that all the Smith chart circles (resistance and reactance) are actually pairs of completely identical circles. They appear to be single for the conventional integer order case, where the identical circles completely overlap each other. The concept is supported by design equations and impedance matching examples. © 2010 IEEE.

  9. Impedance-Source Networks for Electric Power Conversion Part II

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Peng, Fang Zheng; Blaabjerg, Frede

    2015-01-01

    -based power converters has been covered in a previous paper and main topologies were discussed from an application point of view. Now Part II provides a comprehensive review of the most popular control and modulation strategies for impedance-source network-based power converters/inverters. These methods...... are compared in terms of theoretical complexity and performance, when applied to the respective switching topologies. Further, this paper provides as a guide and quick reference for researchers and practicing engineers in deciding which control and modulation method to consider for an application in a given......Impedance-source networks cover the entire spectrum of electric power conversion applications (dc-dc, dc-ac, ac-dc, ac-ac) controlled and modulated by different modulation strategies to generate the desired dc or ac voltage and current at the output. A comprehensive review of various impedance-source-network...

  10. Impedance-Source Networks for Electric Power Conversion Part I

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Peng, Fang Zheng; Blaabjerg, Frede

    2015-01-01

    of the traditional voltage source, current source as well as various classical buck-boost, unidirectional, and bidirectional converter topologies. Proper implementation of the impedance-source network with appropriate switching configurations and topologies reduces the number of power conversion stages in the system...... power chain, which may improve the reliability and performance of the power system. The first part of this paper provides a comprehensive review of the various impedance-source-networks-based power converters and discusses the main topologies from an application point of view. This review paper......Impedance networks cover the entire of electric power conversion from dc (converter, rectifier), ac (inverter), to phase and frequency conversion (ac-ac) in a wide range of applications. Various converter topologies have been reported in the literature to overcome the limitations and problems...

  11. High impedance fault detection in low voltage networks

    Energy Technology Data Exchange (ETDEWEB)

    Christie, R.D. (Univ. of Washington, Seattle, WA (United States). Dept. of Electrical Engineering); Zadehgol, H.; Habib, M.M. (Seattle City Light, WA (United States))

    1993-10-01

    High impedance faults are those with fault current magnitude similar to load currents. Experimental results were obtained that conform operating experience that such faults can occur in the low voltage (600V and below) underground distribution networks typically found in urban power systems. These faults produce current waveforms qualitatively similar to those found on overhead feeders, but quantitatively smaller. Loose connectors can produce similar, but cleaner current characteristics. Noisy loads remain a major impediment to reliable detection. Design and installation of an inexpensive prototype fault detector on the Seattle City Light street network is described.

  12. Hybrid-source impedance network and its generalized cascading concepts

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2009-01-01

    for current-type inverters. These impedance networks can in principle be combined into a single generic network entity, before generalized cascading concepts are proposed for connecting multiple of them together to form energy converters with a higher output voltage gain and other unique advantages....... It is anticipated that these concepts and their formed inverters can find applications in photovoltaic and other renewable systems, which in turn motivate the investigation initiated here on two-level and three-level generalized cascading concepts. In addition to their theoretical performance merits, practical...... shortcomings and relevant transient phenomena exhibited by the generalized concepts are discussed to provide a comprehensive knowledge base needed for weighing relevant tradeoffs before deciding on a particular application....

  13. Asymmetrical Grid Fault Ride-Through Strategy of Three-phase Grid-connected Inverter Considering Network Impedance Impact in Low Voltage Grid

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Zhang, Xue; Wang, Baocheng

    2014-01-01

    inductive, the proposed control strategy is more flexible and effective by considering the network impedance impact, which is of great importance for the high penetration of grid-connected renewable energy systems into low-voltage grids. The experimental tests are carried out to validate the effectiveness...... of the proposed solution for the flexible voltage support in a low-voltage grid, where thenetwork impedance is mainly resistive....

  14. Cable Overheating Risk Warning Method Based on Impedance Parameter Estimation in Distribution Network

    Science.gov (United States)

    Yu, Zhang; Xiaohui, Song; Jianfang, Li; Fei, Gao

    2017-05-01

    Cable overheating will lead to the cable insulation level reducing, speed up the cable insulation aging, even easy to cause short circuit faults. Cable overheating risk identification and warning is nessesary for distribution network operators. Cable overheating risk warning method based on impedance parameter estimation is proposed in the paper to improve the safty and reliability operation of distribution network. Firstly, cable impedance estimation model is established by using least square method based on the data from distribiton SCADA system to improve the impedance parameter estimation accuracy. Secondly, calculate the threshold value of cable impedance based on the historical data and the forecast value of cable impedance based on the forecasting data in future from distribiton SCADA system. Thirdly, establish risks warning rules library of cable overheating, calculate the cable impedance forecast value and analysis the change rate of impedance, and then warn the overheating risk of cable line based on the overheating risk warning rules library according to the variation relationship between impedance and line temperature rise. Overheating risk warning method is simulated in the paper. The simulation results shows that the method can identify the imedance and forecast the temperature rise of cable line in distribution network accurately. The result of overheating risk warning can provide decision basis for operation maintenance and repair.

  15. On the impedance of infinite LC ladder networks

    Science.gov (United States)

    Klimo, Paul

    2017-01-01

    The subject of electrical impedance is on the syllabi of most undergraduate courses in physics and electrical engineering. For example, Richard Feynman in his famous undergraduate text Lectures on Physics shows how to calculate the impedance of an infinite LC ladder. However, the formula he obtains has no useful physical interpretation if considered in the steady state frequency domain. In fact the value of this impedance becomes infinite unless one assumes that the energy flow along the infinite LC ladder is spatially uniform and in one direction only. This ad-hoc assumption, which renders the solution non-causal, is entirely unnecessary if the problem is considered in the time domain. It is important for students to appreciate that the concept of impedance works well only in dissipative circuits where the effects of transients are largely short lived. The purpose of this paper is to show that the same problem treated in the time domain by the Laplace transform method provides a qualitatively different and more satisfying explanation. We show that the current response of an infinite LC ladder, which is in the zero state before a causal harmonic driving voltage is applied, contains a significant non-harmonic component. This component, which is present in addition to the forced harmonic waveform, decays only very slowly and extracts an infinite amount of energy from the source.

  16. The network secrets of great change agents.

    Science.gov (United States)

    Battilana, Julie; Casciaro, Tiziana

    2013-01-01

    Change is hard, especially in a large organization. Yet some leaders succeed--often spectacularly--at transforming their workplaces. what makes them able to exert this sort of influence when the vast majority can't? The authors tracked 68 change initiatives in the UK's National Health Service, an organization whose size, complexity, and tradition can make reform difficult. They discovered several predictors of change agents' success--all of which emphasize the importance of networks of personal relationships: Change agents who were central in the organization's informal network had a clear advantage, regardless of their position in the formal hierarchy. People who bridged disconnected groups or individuals were more effective at implementing dramatic reforms. The resisters in their networks did not necessarily know one another and so were unlikely to form a coalition. Change agents with cohesive networks, in which all individuals were connected, were better at instituting minor changes. Their contacts rallied around the initiative and helped convince others of its importance. Being close to people who were ambivalent about a change was always beneficial. In the end, fence-sitters were reluctant to disappoint a friend. But close relationships with resisters were a double-edged sword: Such ties helped push through minor initiatives but were a hindrance when attempting major change.

  17. Directed weighted network structure analysis of complex impedance measurements for characterizing oil-in-water bubbly flow

    Science.gov (United States)

    Gao, Zhong-Ke; Dang, Wei-Dong; Xue, Le; Zhang, Shan-Shan

    2017-03-01

    Characterizing the flow structure underlying the evolution of oil-in-water bubbly flow remains a contemporary challenge of great interests and complexity. In particular, the oil droplets dispersing in a water continuum with diverse size make the study of oil-in-water bubbly flow really difficult. To study this issue, we first design a novel complex impedance sensor and systematically conduct vertical oil-water flow experiments. Based on the multivariate complex impedance measurements, we define modalities associated with the spatial transient flow structures and construct modality transition-based network for each flow condition to study the evolution of flow structures. In order to reveal the unique flow structures underlying the oil-in-water bubbly flow, we filter the inferred modality transition-based network by removing the edges with small weight and resulting isolated nodes. Then, the weighted clustering coefficient entropy and weighted average path length are employed for quantitatively assessing the original network and filtered network. The differences in network measures enable to efficiently characterize the evolution of the oil-in-water bubbly flow structures.

  18. Impedance measurement techniques for one-port and two-port networks.

    Science.gov (United States)

    Bai, Mingsian R; Lo, Yi-Yang; Chen, You Siang

    2015-10-01

    A microphone array impedance matrix measurement technique is presented for linear and passive acoustic two-port networks. Two impedance tubes fitted with three non-uniformly spaced microphones are required in the measurement. The non-uniform spacing is intended to avoid ill-posedness problems in calculating two plane-wave components traveling in opposite directions. Based on the one-port measurement, acoustic two-port networks modeled with the source and the load connected are examined. Three experimental procedures, the two-load measurement method (TLMM), the reciprocal-constrained method (RCM), and the reciprocity-symmetry-constrained method (RSCM), are developed to measure the acoustic impedance matrix. Experiments are conducted for several acoustic two-port systems to verify the proposed techniques. The results demonstrate the efficacy of the three experimental procedures when applied to symmetrical and reciprocal systems. For asymmetrical systems, the TLMM and RCM are preferred over the RSCM for measuring the impedance matrix. On top of that, the non-uniform array in conjunction with TLMM is extended to a general electroacoustic two-port system, which can be regarded as a unique contribution of the present work.

  19. REG and GREAT, two networks to optimize Gaia scientific exploitation

    Science.gov (United States)

    Figueras, F.; Jordi, C.; Spanish Participants in Reg; Great

    2013-05-01

    The launch of Gaia satellite by the European Space Agency is a year ahead (last quarter of 2013), and Spanish and European community have already out in place two networks devoted to the preparation of the scientific exploitation of the data acquired by the satellite: GREAT (Gaia Research for European Astronomy Training), funded by the European Science Foundation and by Marie Curie Actions in its People 7th Programme, and REG (Spanish Network for the scientific exploitation of Gaia) funded by MINECO. These networks, which are open to the international community, have adopted the challenges of Gaia mission: to revolutionize our understanding of the Milky Way and its components, trace the distribution of dark matter in the local universe, validate and improve models of stellar structure and evolution, characterizing solar system objects, ... and many more. Both networks promote the close interaction among researchers of different institutes, by supporting short and long exchange visits, workshops, schools and large conferences. Currently, 128 Spanish people actively participate in the several working groups in GREAT and REG and 2 students are performing their PhD in the framework of the GREAT-ITN Spanish node. This paper provides detailed information about the structure of these networks, the Spanish participation, and present and future tasks that are foreseen.

  20. Y-source impedance-network-based isolated boost DC/DC converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Town, Graham; Loh, Poh Chiang

    2014-01-01

    A dc-dc converter with very high voltage gain is proposed in this paper for any medium-power application requiring a high voltage boost with galvanic isolation. The proposed converter topology can be realized using only two switches. With this topology a very high voltage boost can be achieved even...... with a relatively low duty cycle of the switches, and the gain obtainable is presently not matched by any existing impedance network based converter operated at the same duty ratio. The proposed converter has a Y-source impedance network to boost the voltage at the intermediate dc-link side and a push......-pull transformer for square-wave AC inversion and isolation. The voltage-doubler rectifier provides a constant dc voltage at the output stage. A theoretical analysis of the converter is presented, supported by simulation and experimental results. A 250 W down-scaled prototype was implemented in the laboratory...

  1. Feature Extraction Method for High Impedance Ground Fault Localization in Radial Power Distribution Networks

    DEFF Research Database (Denmark)

    Jensen, Kåre Jean; Munk, Steen M.; Sørensen, John Aasted

    1998-01-01

    A new approach to the localization of high impedance ground faults in compensated radial power distribution networks is presented. The total size of such networks is often very large and a major part of the monitoring of these is carried out manually. The increasing complexity of industrial...... of three phase voltages and currents. The method consists of a feature extractor, based on a grid description of the feeder by impulse responses, and a neural network for ground fault localization. The emphasis of this paper is the feature extractor, and the detection of the time instance of a ground fault...... processes and communication systems lead to demands for improved monitoring of power distribution networks so that the quality of power delivery can be kept at a controlled level. The ground fault localization method for each feeder in a network is based on the centralized frequency broadband measurement...

  2. Neuronal response impedance mechanism implementing cooperative networks with low firing rates and μs precision.

    Science.gov (United States)

    Vardi, Roni; Goldental, Amir; Marmari, Hagar; Brama, Haya; Stern, Edward A; Sardi, Shira; Sabo, Pinhas; Kanter, Ido

    2015-01-01

    Realizations of low firing rates in neural networks usually require globally balanced distributions among excitatory and inhibitory links, while feasibility of temporal coding is limited by neuronal millisecond precision. We show that cooperation, governing global network features, emerges through nodal properties, as opposed to link distributions. Using in vitro and in vivo experiments we demonstrate microsecond precision of neuronal response timings under low stimulation frequencies, whereas moderate frequencies result in a chaotic neuronal phase characterized by degraded precision. Above a critical stimulation frequency, which varies among neurons, response failures were found to emerge stochastically such that the neuron functions as a low pass filter, saturating the average inter-spike-interval. This intrinsic neuronal response impedance mechanism leads to cooperation on a network level, such that firing rates are suppressed toward the lowest neuronal critical frequency simultaneously with neuronal microsecond precision. Our findings open up opportunities of controlling global features of network dynamics through few nodes with extreme properties.

  3. A network model to correlate conformational change and the impedance spectrum of single proteins

    Science.gov (United States)

    Alfinito, Eleonora; Pennetta, Cecilia; Reggiani, Lino

    2008-02-01

    Integrated nanodevices based on proteins or biomolecules are attracting increasing interest in today's research. In fact, it has been shown that proteins such as azurin and bacteriorhodopsin manifest some electrical properties that are promising for the development of active components of molecular electronic devices. Here we focus on two relevant kinds of protein: bovine rhodopsin, prototype of G-protein-coupled-receptor (GPCR) proteins, and the enzyme acetylcholinesterase (AChE), whose inhibition is one of the most qualified treatments of Alzheimer's disease. Both these proteins exert their function starting with a conformational change of their native structure. Our guess is that such a change should be accompanied with a detectable variation of their electrical properties. To investigate this conjecture, we present an impedance network model of proteins, able to estimate the different impedance spectra associated with the different configurations. The distinct types of conformational change of rhodopsin and AChE agree with their dissimilar electrical responses. In particular, for rhodopsin the model predicts variations of the impedance spectra up to about 30%, while for AChE the same variations are limited to about 10%, which supports the existence of a dynamical equilibrium between its native and complexed states.

  4. LCL filter design for three-phase two-level power factor correction using line impedance stabilization network

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2016-01-01

    This paper presents LCL filter design method for three-phase two-level power factor correction (PFC) using line impedance stabilization network (LISN). A straightforward LCL filter design along with variation in grid impedance is not simply achievable and inevitably lead to an iterative solution...... is derived using the current ripple behavior of converter-side inductor. The grid-side inductor is achieved as a function of LISN impedance to fulfill the grid regulation. To verify the analyses, an LCL filter is designed for a 5 kW SiC-based PFC. The simulation and experimental results support the validity...

  5. ARPA LOMBARDIA river gauging network: a great daily effort

    Science.gov (United States)

    Cislaghi, Matteo; Calabrese, Michele; Condemi, Leonardo; Di Priolo, Sara; Parravicini, Paola; Rondanini, Chiara; Russo, Michele; Cazzuli, Orietta; Mussin, Mauro; Serra, Roberto

    2017-04-01

    ARPA to collect and publish data every 10 minutes. ARPA also decided to freely publish all hydrological data on its web site (http://idro.arpalombardia.it). Since 2010 either real time data or historical long series have been made available to everyone over a webgis platform. Every day ARPA employs check if the network is working correctly and validate the data. The aim is to follow the whole process of data management from its collection on the field to its open publication; this requires a great daily effort from the people in charge of the network maintenance.

  6. Total Differential Errors in One-Port Network Analyzer Measurements with Application to Antenna Impedance

    Directory of Open Access Journals (Sweden)

    P. Zimourtopoulos

    2007-06-01

    Full Text Available The objective was to study uncertainty in antenna input impedance resulting from full one-port Vector Network Analyzer (VNA measurements. The VNA process equation in the reflection coefficient ρ of a load, its measurement m and three errors Es, determinable from three standard loads and their measurements, was considered. Differentials were selected to represent measurement inaccuracies and load uncertainties (Differential Errors. The differential operator was applied on the process equation and the total differential error dρ for any unknown load (Device Under Test DUT was expressed in terms of dEs and dm, without any simplification. Consequently, the differential error of input impedance Z -or any other physical quantity differentiably dependent on ρ- is expressible. Furthermore, to express precisely a comparison relation between complex differential errors, the geometric Differential Error Region and its Differential Error Intervals were defined. Practical results are presented for an indoor UHF ground-plane antenna in contrast with a common 50 Ω DC resistor inside an aluminum box. These two built, unshielded and shielded, DUTs were tested against frequency under different system configurations and measurement considerations. Intermediate results for Es and dEs characterize the measurement system itself. A number of calculations and illustrations demonstrate the application of the method.

  7. Dimension Estimation of Rectangular Cracks Using Impedance Changes of the Eddy Current Probe with a Neural Network

    Directory of Open Access Journals (Sweden)

    A. Babaei

    2013-06-01

    Full Text Available In this paper a method for estimating the dimension of rectangular cracks is proposed. The use of Eddy current (ECnondestructive testing (NDT based on probe impedance changes on the crack regions is considered. The artificialneural network estimates the dimension of new cracks using impedance changes of the eddy current probe. Theexperimental results and finite element method (FEM results are used for training the artificial neural network. Byincreasing the number of experiments, the results of the finite element method are not necessary. The simulationresults are very promising.

  8. Three-Level Z-Source Inverters Using a Single LC Impedance Network

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Lim, Sok Wei; Gao, Feng

    2007-01-01

    Three-level Z-source inverters are recent single-stage topological solutions proposed for buck-boost energy conversion with all favorable advantages of three-level switching retained. Despite their effectiveness in achieving voltage buck-boost conversion, existing three-level Z-source inverters use...... three-level Z-source inverters, whose output voltage can be stepped down or up using only a single LC impedance network connected between the dc input source and either a neutral-point-clamped (NPC) or dc-link cascaded inverter circuitry. Through careful design of their modulation scheme, both inverters...... can function with the minimum of six device commutations per half carrier cycle (similar to that needed by a traditional buck three-level NPC inverter), while producing the correct volt-sec average and inductive voltage boosting at their ac output terminals. Physically, the designed modulation scheme...

  9. Efficiency Enhancement for an Inductive Wireless Power Transfer System by Optimizing the Impedance Matching Networks.

    Science.gov (United States)

    Miao, Zhidong; Liu, Dake; Gong, Chen

    2017-10-01

    Inductive wireless power transfer (IWPT) is a promising power technology for implantable biomedical devices, where the power consumption is low and the efficiency is the most important consideration. In this paper, we propose an optimization method of impedance matching networks (IMN) to maximize the IWPT efficiency. The IMN at the load side is designed to achieve the optimal load, and the IMN at the source side is designed to deliver the required amount of power (no-more-no-less) from the power source to the load. The theoretical analyses and design procedure are given. An IWPT system for an implantable glaucoma therapeutic prototype is designed as an example. Compared with the efficiency of the resonant IWPT system, the efficiency of our optimized system increases with a factor of 1.73. Besides, the efficiency of our optimized IWPT system is 1.97 times higher than that of the IWPT system optimized by the traditional maximum power transfer method. All the discussions indicate that the optimization method proposed in this paper could achieve a high efficiency and long working time when the system is powered by a battery.

  10. An Adaptive Impedance Matching Network with Closed Loop Control Algorithm for Inductive Wireless Power Transfer.

    Science.gov (United States)

    Miao, Zhidong; Liu, Dake; Gong, Chen

    2017-08-01

    For an inductive wireless power transfer (IWPT) system, maintaining a reasonable power transfer efficiency and a stable output power are two most challenging design issues, especially when coil distance varies. To solve these issues, this paper presents a novel adaptive impedance matching network (IMN) for IWPT system. In our adaptive IMN IWPT system, the IMN is automatically reconfigured to keep matching with the coils and to adjust the output power adapting to coil distance variation. A closed loop control algorithm is used to change the capacitors continually, which can compensate mismatches and adjust output power simultaneously. The proposed adaptive IMN IWPT system is working at 125 kHz for 2 W power delivered to load. Comparing with the series resonant IWPT system and fixed IMN IWPT system, the power transfer efficiency of our system increases up to 31.79% and 60% when the coupling coefficient varies in a large range from 0.05 to 0.8 for 2 W output power.

  11. Paenibacillus thiaminolyticus is not the cause of thiamine deficiency impeding lake trout (Salvelinus namaycush) recruitment in the Great Lakes

    Science.gov (United States)

    Richter, Catherine A.; Evans, Allison N.; Wright-Osment, Maureen K.; Zajicek, James L.; Heppell, Scott A.; Riley, Stephen C.; Krueger, Charles C.; Tillitt, Donald E.

    2012-01-01

    Thiamine (vitamin B1) deficiency is a global concern affecting wildlife, livestock, and humans. In Great Lakes salmonines, thiamine deficiency causes embryo mortality and is an impediment to restoration of native lake trout (Salvelinus namaycush) stocks. Thiamine deficiency in fish may result from a diet of prey with high levels of thiaminase I. The discoveries that the bacterial species Paenibacillus thiaminolyticus produces thiaminase I, is found in viscera of thiaminase-containing prey fish, and causes mortality when fed to lake trout in the laboratory provided circumstantial evidence implicating P. thiaminolyticus. This study quantified the contribution of P. thiaminolyticus to the total thiaminase I activity in multiple trophic levels of Great Lakes food webs. Unexpectedly, no relationship between thiaminase activity and either the amount of P. thiaminolyticus thiaminase I protein or the abundance of P. thiaminolyticus cells was found. These results demonstrate that P. thiaminolyticus is not the primary source of thiaminase activity affecting Great Lakes salmonines and calls into question the long-standing assumption that P. thiaminolyticus is the source of thiaminase in other wild and domestic animals.

  12. Modeling of bulk acoustic wave devices built on piezoelectric stack structures: impedance matrix analysis and network representation.

    Science.gov (United States)

    Zhang, Victor Y; Dubus, Bertrand; Lefebvre, Jean Etienne; Gryba, Tadeusz

    2008-03-01

    The fundamental electro-acoustic properties of a solid layer are deduced in terms of its impedance matrix (Z) and represented by a network for modeling the bulk acoustic wave devices built on piezoelectric stacked structures. A piezoelectric layer is described by a three-port equivalent network, a nonpiezoelectric layer, and a short- or open-circuit piezoelectric layer by a two-port one. Electrical input impedance of the resonator is derived in terms of the Z-matrix of both the piezoelectric layer and an external load, the unique expression applies whether the resonator is a mono- or electroded-layer or a solidly mounted resonator (SMR). The loading effects of Al-electrodes on the resonating frequencies of the piezoelectric ZnO-layer are analyzed. Transmission and reflection properties of Bragg mirrors are investigated along with the bulk radiation in SMR. As a synthesizing example, a coupled resonator filter (CRF) is analyzed using the associated two-port equivalent network and by calculating the power transmission to a 50Omega-load. The stacked crystal filter is naturally included in the model as a special case of CRF. Combining a comprehensive matrix analysis and an instructive network representation and setting the problem with a full vectorial formalism are peculiar features of the presented approach.

  13. Comparison of the Impedance-Source Networks for Two and Multilevel Buck-Boost Inverter Applications

    DEFF Research Database (Denmark)

    Husev, Oleksandr; Blaabjerg, Frede; Roncero-Clemente, Carlos

    2016-01-01

    described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison of the impedance-source-based buck–boost inverters in terms of passive component count and semiconductor stress. Based on the waveform of the input current, i.......e., with or without a transformer, and with or without inductor coupling, the impedance-source converters are classified. The main criterion in our comprehensive comparison is the energy stored in the passive elements, which is considered both under constant and predefined high frequency current ripple...... in the inductors and the voltage ripple across the capacitors. Two-level and multilevel solutions are described. The conclusions provide a “one-stop” information source and a selection guide of impedance-source-based buck–boost inverters for different applications....

  14. Impedance Spectroscopic Characterisation of Porosity in 3D Cell Culture Scaffolds with Different Channel Networks

    DEFF Research Database (Denmark)

    Canali, Chiara; Mohanty, Soumyaranjan; Heiskanen, Arto

    2015-01-01

    We present the application of electrochemical impedance spectroscopy (EIS) as a method for discriminating between different polydimethylsiloxane (PDMS) scaffolds for three-dimensional (3D) cell cultures. The validity of EIS characterisation for scaffolds having different degree of porosity...... serve as means of single-frequency measurements for fast scaffold characterization combined with in vitro monitoring of 3D cell cultures....

  15. Progress towards design elements for a Great Lakes-wide aquatic invasive species early detection network

    Science.gov (United States)

    Great Lakes coastal systems are vulnerable to introduction of a wide variety of non-indigenous species (NIS), and the desire to effectively respond to future invaders is prompting efforts towards establishing a broad early-detection network. Such a network requires statistically...

  16. Network analysis of semiconducting Zn1-xCdxS based photosensitive device using impedance spectroscopy and current-voltage measurement

    Science.gov (United States)

    Datta, Joydeep; Das, Mrinmay; Dey, Arka; Halder, Soumi; Sil, Sayantan; Ray, Partha Pratim

    2017-10-01

    ZnCdS is an intermediate ternary alloy type semiconducting material which has huge tunable structural, optical and electrical properties. Here, we have synthesized Zn1-xCdxS compound and characterized its structural, optical and charge transport properties. It is seen that the particle size is greatly influenced by the amount of alloy concentration of cadmium. The performance of semiconductor device such as Schottky diode depends mainly on the charge transportation through the metal-semiconductor junction. So, we have fabricated Al/Zn1-xCdxS/ITO device and investigated the bias dependent impedance properties through equivalent circuit network analysis to study the electron lifetime and interfacial region resistance. The result of network analysis indicates that the charge transportation through Al- Zn0.6Cd0.4S is better than the other fabricated devices. For further explanation, we have studied the capacitance-voltage (C-V) characteristic under dark and current-voltage (I-V) characteristic under dark and light. We have investigated barrier height, depletion layer width and employed SCLC (space charge limited current) theory in I-V characteristics to determine mobility, transit time and diffusion length. The mobility and diffusion length for Zn0.6Cd0.4S fabricated device are derived as 23.01 m2 V-1 s-1 and 4.4 μm respectively while both the values are less for the other devices. These values are enhanced upon illumination for all the devices but superiority comes from the Al/Zn0.6Cd0.4S/ITO device and it leads us to measure the photosensitivity, responsivity, specific detectivity. As expected, the photosensing parameters are enhanced for the Zn0.6Cd0.4S fabricated device. So, this literature not only explores the metal semiconductor charge transportation using impedance spectroscopy (IS) network analysis and SCLC theory but also explain it from the structural point of view.

  17. Synthesis of Variable Harmonic Impedance in Inverter-Interfaced Distributed Generation Unit for Harmonic Damping Throughout a Distribution Network

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2012-01-01

    at the dominant harmonic frequencies. Thus, the harmonic voltage drop on the grid-side inductance and the harmonic resonances throughout a distribution feeder with multiple shunt-connected capacitors can be effectively attenuated. Simulation and laboratory test results validate the performance of the proposed......This paper proposes a harmonic impedance synthesis technique for voltage-controlled distributed generation inverters in order to damp harmonic voltage distortion on a distribution network. The approach employs a multiloop control scheme, where a selective harmonic load current feedforward loop...... based on the bandpass filter is developed, in addition to the inner inductor current and the outer capacitor voltage control loops. Together with the use of multiple resonant integrators in the voltage control loop, the negative harmonic inductances and positive harmonic resistances are synthesized...

  18. Synthesis of variable harmonic impedance in inverter-interfaced distributed generation unit for harmonic damping throughout a distribution network

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2012-01-01

    harmonic frequencies. Thus, the harmonic voltage drop and harmonic resonances throughout a distribution line with multiple shunt-connected capacitors can be effectively attenuated. Simulation and laboratory test results are shown to verify the performance of the proposed control method.......This paper proposes a harmonic impedance synthesis technique for voltage-controlled distributed generation inverter in order to damp harmonic voltage distortion on a distribution network. The approach employs a multiloop control scheme, where a selective load harmonic current feedforward loop based...... on band-pass filter is developed in addition to the inner inductor current and the outer capacitor voltage control loops. Together with the use of multiple resonant integrators in the voltage control loop, the negative harmonic inductances and positive harmonic resistances are synthesized at dominant...

  19. Progress towards an AIS early detection monitoring network for the Great Lakes

    Science.gov (United States)

    As an invasion prone location, the lower St. Louis River system (SLR) has been a case study for ongoing research to develop the framework for a practical Great Lakes monitoring network for early detection of aquatic invasive species (AIS). Early detection, however, necessitates f...

  20. Redrawing the map of Great Britain from a network of human interactions.

    Directory of Open Access Journals (Sweden)

    Carlo Ratti

    Full Text Available Do regional boundaries defined by governments respect the more natural ways that people interact across space? This paper proposes a novel, fine-grained approach to regional delineation, based on analyzing networks of billions of individual human transactions. Given a geographical area and some measure of the strength of links between its inhabitants, we show how to partition the area into smaller, non-overlapping regions while minimizing the disruption to each person's links. We tested our method on the largest non-Internet human network, inferred from a large telecommunications database in Great Britain. Our partitioning algorithm yields geographically cohesive regions that correspond remarkably well with administrative regions, while unveiling unexpected spatial structures that had previously only been hypothesized in the literature. We also quantify the effects of partitioning, showing for instance that the effects of a possible secession of Wales from Great Britain would be twice as disruptive for the human network than that of Scotland.

  1. Influence of the Antenna Impedance Variation and Input Matching Network Q on LNA Key Figures

    DEFF Research Database (Denmark)

    Ruaro, Andrea; Kvist, Søren Helstrup; Gülstorff, Steen

    2012-01-01

    In this paper we present an analysis of the behaviour of a 2:4 GHz Low Noise Amplifier (LNA) for Wireless Body Area Network (WBAN) applications facing antennadetuning issue. An amplifier with ultra-low power, low voltage, and with reduced component count is prototyped to validate simulation resul...

  2. Water quality monitoring protocol for wadeable streams and rivers in the Northern Great Plains Network

    Science.gov (United States)

    Marcia H. Wilson,; Rowe, Barbara L.; Robert A. Gitzen,; Stephen K. Wilson,; Kara J. Paintner-Green,

    2014-01-01

    Preserving the national parks unimpaired for the enjoyment of future generations is a fundamental purpose of the National Park Service (NPS). To address growing concerns regarding the overall physical, chemical, and biological elements and processes of park ecosystems, the NPS implemented science-based management through “Vital Signs” monitoring in 270 national parks (NPS 2007). The Northern Great Plains Network (NGPN) is among the 32 National Park Service Networks participating in this monitoring effort. The NGPN will develop protocols over the next several years to determine the overall health or condition of resources within 13 parks located in Nebraska, North Dakota, South Dakota, and Wyoming.

  3. Functional brain networks: great expectations, hard times and the big leap forward.

    Science.gov (United States)

    Papo, David; Zanin, Massimiliano; Pineda-Pardo, José Angel; Boccaletti, Stefano; Buldú, Javier M

    2014-10-05

    Many physical and biological systems can be studied using complex network theory, a new statistical physics understanding of graph theory. The recent application of complex network theory to the study of functional brain networks has generated great enthusiasm as it allows addressing hitherto non-standard issues in the field, such as efficiency of brain functioning or vulnerability to damage. However, in spite of its high degree of generality, the theory was originally designed to describe systems profoundly different from the brain. We discuss some important caveats in the wholesale application of existing tools and concepts to a field they were not originally designed to describe. At the same time, we argue that complex network theory has not yet been taken full advantage of, as many of its important aspects are yet to make their appearance in the neuroscience literature. Finally, we propose that, rather than simply borrowing from an existing theory, functional neural networks can inspire a fundamental reformulation of complex network theory, to account for its exquisitely complex functioning mode. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  4. A novel post-processing scheme for two-dimensional electrical impedance tomography based on artificial neural networks.

    Science.gov (United States)

    Martin, Sébastien; Choi, Charles T M

    2017-01-01

    Electrical Impedance Tomography (EIT) is a powerful non-invasive technique for imaging applications. The goal is to estimate the electrical properties of living tissues by measuring the potential at the boundary of the domain. Being safe with respect to patient health, non-invasive, and having no known hazards, EIT is an attractive and promising technology. However, it suffers from a particular technical difficulty, which consists of solving a nonlinear inverse problem in real time. Several nonlinear approaches have been proposed as a replacement for the linear solver, but in practice very few are capable of stable, high-quality, and real-time EIT imaging because of their very low robustness to errors and inaccurate modeling, or because they require considerable computational effort. In this paper, a post-processing technique based on an artificial neural network (ANN) is proposed to obtain a nonlinear solution to the inverse problem, starting from a linear solution. While common reconstruction methods based on ANNs estimate the solution directly from the measured data, the method proposed here enhances the solution obtained from a linear solver. Applying a linear reconstruction algorithm before applying an ANN reduces the effects of noise and modeling errors. Hence, this approach significantly reduces the error associated with solving 2D inverse problems using machine-learning-based algorithms. This work presents radical enhancements in the stability of nonlinear methods for biomedical EIT applications.

  5. Impedance Scaling and Impedance Control

    Energy Technology Data Exchange (ETDEWEB)

    Chou, W.; Griffin, J.

    1997-06-01

    When a machine becomes really large, such as the Very Large Hadron Collider (VLHC), of which the circumference could reach the order of megameters, beam instability could be an essential bottleneck. This paper studies the scaling of the instability threshold vs. machine size when the coupling impedance scales in a ``normal`` way. It is shown that the beam would be intrinsically unstable for the VLHC. As a possible solution to this problem, it is proposed to introduce local impedance inserts for controlling the machine impedance. In the longitudinal plane, this could be done by using a heavily detuned rf cavity (e.g., a biconical structure), which could provide large imaginary impedance with the right sign (i.e., inductive or capacitive) while keeping the real part small. In the transverse direction, a carefully designed variation of the cross section of a beam pipe could generate negative impedance that would partially compensate the transverse impedance in one plane.

  6. Microwave Impedance Measurement for Nanoelectronics

    Directory of Open Access Journals (Sweden)

    M. Randus

    2011-04-01

    Full Text Available The rapid progress in nanoelectronics showed an urgent need for microwave measurement of impedances extremely different from the 50Ω reference impedance of measurement instruments. In commonly used methods input impedance or admittance of a device under test (DUT is derived from measured value of its reflection coefficient causing serious accuracy problems for very high and very low impedances due to insufficient sensitivity of the reflection coefficient to impedance of the DUT. This paper brings theoretical description and experimental verification of a method developed especially for measurement of extreme impedances. The method can significantly improve measurement sensitivity and reduce errors caused by the VNA. It is based on subtraction (or addition of a reference reflection coefficient and the reflection coefficient of the DUT by a passive network, amplifying the resulting signal by an amplifier and measuring the amplified signal as a transmission coefficient by a common vector network analyzer (VNA. A suitable calibration technique is also presented.

  7. Cyberinfrastructure for remote environmental observatories: a model homogeneous sensor network in the Great Basin, USA

    Science.gov (United States)

    Strachan, Scotty; Slater, David; Fritzinger, Eric; Lyles, Bradley; Kent, Graham; Smith, Kenneth; Dascalu, Sergiu; Harris, Frederick

    2017-04-01

    Sensor-based data collection has changed the potential scale and resolution of in-situ environmental studies by orders of magnitude, increasing expertise and management requirements accordingly. Cost-effective management of these observing systems is possible by leveraging cyberinfrastructure resources. Presented is a case study environmental observation network in the Great Basin region, USA, the Nevada Climate-ecohydrological Assessment Network (NevCAN). NevCAN stretches hundreds of kilometers across several mountain ranges and monitors climate and ecohydrological conditions from low desert (900 m ASL) to high subalpine treeline (3360 m ASL) down to 1-minute timescales. The network has been operating continuously since 2010, collecting billions of sensor data points and millions of camera images that record hourly conditions at each site, despite requiring relatively low annual maintenance expenditure. These data have provided unique insight into fine-scale processes across mountain gradients, which is crucial scientific information for a water-scarce region. The key to maintaining data continuity for these remotely-located study sites has been use of uniform data transport and management systems, coupled with high-reliability power system designs. Enabling non-proprietary digital communication paths to all study sites and sensors allows the research team to acquire data in near-real-time, troubleshoot problems, and diversify sensor hardware. A wide-area network design based on common Internet Protocols (IP) has been extended into each study site, providing production bandwidth of between 2 Mbps and 60 Mbps, depending on local conditions. The network architecture and site-level support systems (such as power generation) have been implemented with the core objectives of capacity, redundancy, and modularity. NevCAN demonstrates that by following simple but uniform "best practices", the next generation of regionally-specific environmental observatories can evolve to

  8. To tweet or not to tweet : the role of personality in the social networks of great tits

    NARCIS (Netherlands)

    Snijders, L.

    2016-01-01

    To tweet or not to tweet: The role of personality in the social networks of great tits
    By: Lysanne Snijders Project video: https://www.youtube.com/watch?v=zy0HysxhQz0 When mentioning social networks it

  9. Low impedance walking robots.

    Science.gov (United States)

    Pratt, Gill Andrews

    2002-02-01

    For both historical and technological reasons, most robots, including those meant to mimic animals or operate in natural environments,3 use actuators and control systems that have high (stiff) mechanical impedance. By contrast, most animals exhibit low (soft) impedance. While a robot's stiff joints may be programmed to closely imitate the recorded motion of an animal's soft joints, any unexpected position disturbances will generate reactive forces and torques much higher for the robot than for the animal. The dual of this is also true: while an animal will react to a force disturbance by significantly yielding position, a typical robot will greatly resist.These differences cause three deleterious effects for high impedance robots. First, the higher forces may cause damage to the robot or to its environment (which is particularly important if that environment includes people). Second, the robot must acquire very precise information about its position relative to the environment so as to minimize its velocity upon impact. Third, many of the self-stabilizing effects of natural dynamics are "shorted out"4 by the robot's high impedance, so that stabilization requires more effort from the control system.Over the past 5 yr, our laboratory has designed a series of walking robots based on "Series-Elastic Actuators" and "Virtual Model Control." Using these two techniques, we have been able to build low-impedance walking robots that are both safe and robust, that operate blindly without any model of upcoming terrain, and that add minimal control effort in parallel to their self-stabilizing passive dynamics. We have discovered that it is possible to achieve surprisingly effective ambulation from rather simple mechanisms and control systems. After describing the historical and technological motivations for our approach, this paper gives an overview of our methods and shows some of the results we have obtained.

  10. Northern Great Plains Network water quality monitoring design for tributaries to the Missouri National Recreational River

    Science.gov (United States)

    Rowe, Barbara L.; Wilson, Stephen K.; Yager, Lisa; Wilson, Marcia H.

    2013-01-01

    The National Park Service (NPS) organized more than 270 parks with important natural resources into 32 ecoregional networks to conduct Inventory and Monitoring (I&M) activities for assessment of natural resources within park units. The Missouri National Recreational River (NRR) is among the 13 parks in the NPS Northern Great Plain Network (NGPN). Park managers and NGPN staff identified surface water resources as a high priority vital sign to monitor in park units. The objectives for the Missouri NRR water quality sampling design are to (1) assess the current status and long-term trends of select water quality parameters; and (2) document trends in streamflow at high-priority stream systems. Due to the large size of the Missouri River main stem, the NGPN water quality design for the Missouri NRR focuses on wadeable tributaries within the park unit. To correlate with the NGPN water quality protocols, monitoring of the Missouri NRR consists of measurement of field core parameters including dissolved oxygen, pH, specific conductance, and temperature; and streamflow. The purpose of this document is to discuss factors examined for selection of water quality monitoring on segments of the Missouri River tributaries within the Missouri NRR.Awareness of the complex history of the Missouri NRR aids in the current understanding and direction for designing a monitoring plan. Historical and current monitoring data from agencies and entities were examined to assess potential NGPN monitoring sites. In addition, the U.S. Environmental Protection Agency 303(d) list was examined for the impaired segments on tributaries to the Missouri River main stem. Because major tributaries integrate water quality effects from complex combinations of land use and environmental settings within contributing areas, a 20-mile buffer of the Missouri NRR was used to establish environmental settings that may impact the water quality of tributaries that feed the Missouri River main stem. For selection of

  11. Relationship of white matter network topology and cognitive outcome in adolescents with d-transposition of the great arteries.

    Science.gov (United States)

    Panigrahy, Ashok; Schmithorst, Vincent J; Wisnowski, Jessica L; Watson, Christopher G; Bellinger, David C; Newburger, Jane W; Rivkin, Michael J

    2015-01-01

    Patients with congenital heart disease (CHD) are at risk for neurocognitive impairments. Little is known about the impact of CHD on the organization of large-scale brain networks. We applied graph analysis techniques to diffusion tensor imaging (DTI) data obtained from 49 adolescents with dextro-transposition of the great arteries (d-TGA) repaired with the arterial switch operation in early infancy and 29 healthy referent adolescents. We examined whether differences in neurocognitive functioning were related to white matter network topology. We developed mediation models revealing the respective contributions of peri-operative variables and network topology on cognitive outcome. Adolescents with d-TGA had reduced global efficiency at a trend level (p = 0.061), increased modularity (p = 0.012), and increased small-worldness (p = 0.026) as compared to controls. Moreover, these network properties mediated neurocognitive differences between the d-TGA and referent adolescents across every domain assessed. Finally, structural network topology mediated the neuroprotective effect of longer duration of core cooling during reparative neonatal cardiac surgery, as well as the detrimental effects of prolonged hospitalization. Taken together, worse neurocognitive function in adolescents with d-TGA is mediated by global differences in white matter network topology, suggesting that disruption of this configuration of large-scale networks drives neurocognitive dysfunction. These data provide new insights into the interplay between perioperative factors, brain organization, and cognition in patients with complex CHD.

  12. Stepped-impedance phase shifters

    CERN Document Server

    Faltin, L

    1977-01-01

    A coupled-line phase shifter can be decomposed in two lines of stepped characteristic impedances, interconnected by a 180 degrees hybrid. This network permits phase responses which cannot be realised with coupled lines. Practical simplifications are possible by omitting one of the two lines or by using a 90 degrees hybrid. (5 refs).

  13. Individual personalities predict social behaviour in wild networks of great tits (Parus major).

    Science.gov (United States)

    Aplin, L M; Farine, D R; Morand-Ferron, J; Cole, E F; Cockburn, A; Sheldon, B C

    2013-11-01

    Social environments have an important effect on a range of ecological processes, and form a crucial component of selection. However, little is known of the link between personality, social behaviour and population structure. We combine a well-understood personality trait with large-scale social networks in wild songbirds, and show that personality underpins multiple aspects of social organisation. First, we demonstrate a relationship between network centrality and personality with 'proactive' (fast-exploring) individuals associating weakly with greater numbers of conspecifics and moving between flocks. Second, temporal stability of associations relates to personality: 'reactive' (slow-exploring) birds form synergistically stable relationships. Finally, we show that personality influences social structure, with males non-randomly distributed across groups. These results provide strong evidence that songbirds follow alternative social strategies related to personality. This has implications not only for the causes of social network structure but also for the strength and direction of selection on personality in natural populations. © 2013 John Wiley & Sons Ltd/CNRS.

  14. Sex-specific responses to territorial intrusions in a communication network: Evidence from radio-tagged great tits.

    Science.gov (United States)

    Snijders, Lysanne; van Oers, Kees; Naguib, Marc

    2017-02-01

    Signals play a key role in the ecology and evolution of animal populations, influencing processes such as sexual selection and conflict resolution. In many species, sexually selected signals have a dual function: attracting mates and repelling rivals. Yet, to what extent males and females under natural conditions differentially respond to such signals remains poorly understood, due to a lack of field studies that simultaneously track both sexes. Using a novel spatial tracking system, we tested whether or not the spatial behavior of male and female great tits (Parus major) changes in relation to the vocal response of a territorial male neighbor to an intruder. We tracked the spatial behavior of male and female great tits (N = 44), 1 hr before and 1 hr after simulating territory intrusions, employing automatized Encounternet radio-tracking technology. We recorded the spatial and vocal response of the challenged males and quantified attraction and repulsion of neighboring males and females to the intrusion site. We additionally quantified the direct proximity network of the challenged male. The strength of a male's vocal response to an intruder induced sex-dependent movements in the neighborhood, via female attraction and male repulsion. Stronger vocal responders were older and in better body condition. The proximity networks of the male vocal responders, including the number of sex-dependent connections and average time spent with connections, however, did not change directly following the intrusion. The effects on neighbor movements suggest that the strength of a male's vocal response can provide relevant social information to both the males and the females in the neighborhood, resulting in both sexes adjusting their spatial behavior in contrasting ways, while the social proximity network remained stable. This study underlines the importance of "silent" eavesdroppers within communication networks for studying the dual functioning and evolution of sexually

  15. Graph theory analysis of cortical thickness networks in adolescents with d-transposition of the great arteries.

    Science.gov (United States)

    Watson, Christopher G; Stopp, Christian; Newburger, Jane W; Rivkin, Michael J

    2018-02-01

    Adolescents with d-transposition of the great arteries (d-TGA) who had the arterial switch operation in infancy have been found to have structural brain differences compared to healthy controls. We used cortical thickness measurements obtained from structural brain MRI to determine group differences in global brain organization using a graph theoretical approach. Ninety-two d-TGA subjects and 49 controls were scanned using one of two identical 1.5-Tesla MRI systems. Mean cortical thickness was obtained from 34 regions per hemisphere using Freesurfer. A linear model was used for each brain region to adjust for subject age, sex, and scanning location. Structural connectivity for each group was inferred based on the presence of high inter-regional correlations of the linear model residuals, and binary connectivity matrices were created by thresholding over a range of correlation values for each group. Graph theory analysis was performed using packages in R. Permutation tests were performed to determine significance of between-group differences in global network measures. Within-group connectivity patterns were qualitatively different between groups. At lower network densities, controls had significantly more long-range connections. The location and number of hub regions differed between groups: controls had a greater number of hubs at most network densities. The control network had a significant rightward asymmetry compared to the d-TGA group at all network densities. Using graph theory analysis of cortical thickness correlations, we found differences in brain structural network organization among d-TGA adolescents compared to controls. These may be related to the white matter and gray matter differences previously found in this cohort, and in turn may be related to the cognitive deficits this cohort presents.

  16. Using prediction uncertainty analysis to design hydrologic monitoring networks: Example applications from the Great Lakes water availability pilot project

    Science.gov (United States)

    Fienen, Michael N.; Doherty, John E.; Hunt, Randall J.; Reeves, Howard W.

    2010-01-01

    The importance of monitoring networks for resource-management decisions is becoming more recognized, in both theory and application. Quantitative computer models provide a science-based framework to evaluate the efficacy and efficiency of existing and possible future monitoring networks. In the study described herein, two suites of tools were used to evaluate the worth of new data for specific predictions, which in turn can support efficient use of resources needed to construct a monitoring network. The approach evaluates the uncertainty of a model prediction and, by using linear propagation of uncertainty, estimates how much uncertainty could be reduced if the model were calibrated with addition information (increased a priori knowledge of parameter values or new observations). The theoretical underpinnings of the two suites of tools addressing this technique are compared, and their application to a hypothetical model based on a local model inset into the Great Lakes Water Availability Pilot model are described. Results show that meaningful guidance for monitoring network design can be obtained by using the methods explored. The validity of this guidance depends substantially on the parameterization as well; hence, parameterization must be considered not only when designing the parameter-estimation paradigm but also-importantly-when designing the prediction-uncertainty paradigm.

  17. Adaptive management of the Great Barrier Reef: a globally significant demonstration of the benefits of networks of marine reserves.

    Science.gov (United States)

    McCook, Laurence J; Ayling, Tony; Cappo, Mike; Choat, J Howard; Evans, Richard D; De Freitas, Debora M; Heupel, Michelle; Hughes, Terry P; Jones, Geoffrey P; Mapstone, Bruce; Marsh, Helene; Mills, Morena; Molloy, Fergus J; Pitcher, C Roland; Pressey, Robert L; Russ, Garry R; Sutton, Stephen; Sweatman, Hugh; Tobin, Renae; Wachenfeld, David R; Williamson, David H

    2010-10-26

    The Great Barrier Reef (GBR) provides a globally significant demonstration of the effectiveness of large-scale networks of marine reserves in contributing to integrated, adaptive management. Comprehensive review of available evidence shows major, rapid benefits of no-take areas for targeted fish and sharks, in both reef and nonreef habitats, with potential benefits for fisheries as well as biodiversity conservation. Large, mobile species like sharks benefit less than smaller, site-attached fish. Critically, reserves also appear to benefit overall ecosystem health and resilience: outbreaks of coral-eating, crown-of-thorns starfish appear less frequent on no-take reefs, which consequently have higher abundance of coral, the very foundation of reef ecosystems. Effective marine reserves require regular review of compliance: fish abundances in no-entry zones suggest that even no-take zones may be significantly depleted due to poaching. Spatial analyses comparing zoning with seabed biodiversity or dugong distributions illustrate significant benefits from application of best-practice conservation principles in data-poor situations. Increases in the marine reserve network in 2004 affected fishers, but preliminary economic analysis suggests considerable net benefits, in terms of protecting environmental and tourism values. Relative to the revenue generated by reef tourism, current expenditure on protection is minor. Recent implementation of an Outlook Report provides regular, formal review of environmental condition and management and links to policy responses, key aspects of adaptive management. Given the major threat posed by climate change, the expanded network of marine reserves provides a critical and cost-effective contribution to enhancing the resilience of the Great Barrier Reef.

  18. Calibration of electrical impedance tomography

    Energy Technology Data Exchange (ETDEWEB)

    Daily, W; Ramirez, A

    2000-05-01

    Over the past 10 years we have developed methods for imaging the electrical resistivity of soil and rock formations. These technologies have been called electrical resistance tomography of ERT (e.g. Daily and Owen, 1991). Recently we have been striving to extend this capability to include images of electric impedance--with a new nomenclature of electrical impedance tomography or EIT (Ramirez et al., 1999). Electrical impedance is simply a generalization of resistance. Whereas resistance is the zero frequency ratio of voltage and current, impedance includes both the magnitude and phase relationship between voltage and current at frequency. This phase and its frequency behavior is closely related to what in geophysics is called induced polarization or (Sumner, 1976). Why is this phase or IP important? IP is known to be related to many physical phenomena of importance so that image of IP will be maps of such things as mineralization and cation exchange IP (Marshall and Madden, 1959). Also, it is likely that IP, used in conjunction with resistivity, will yield information about the subsurface that can not be obtained by either piece of information separately. In order to define the accuracy of our technologies to image impedance we have constructed a physical model of known impedance that can be used as a calibration standard. It consists of 616 resistors, along with some capacitors to provide the reactive response, arranged in a three dimensional structure as in figure 1. Figure 2 shows the construction of the network and defines the coordinate system used to describe it. This network of components is a bounded and discrete version of the unbounded and continuous medium with which we normally work (the subsurface). The network has several desirable qualities: (1) The impedance values are known (to the accuracy of the component values). (2) The component values and their 3D distribution is easily controlled. (3) Error associated with electrode noise is eliminated. (4

  19. Using a network modularity analysis to inform management of a rare endemic plant in the northern Great Plains, USA

    Science.gov (United States)

    Larson, Diane L.; Droege, Sam; Rabie, Paul A.; Larson, Jennifer L.; Devalez, Jelle; Haar, Milton; McDermott-Kubeczko, Margaret

    2014-01-01

    1. Analyses of flower-visitor interaction networks allow application of community-level information to conservation problems, but management recommendations that ensue from such analyses are not well characterized. Results of modularity analyses, which detect groups of species (modules) that interact more with each other than with species outside their module, may be particularly applicable to management concerns. 2. We conducted modularity analyses of networks surrounding a rare endemic annual plant, Eriogonum visheri, at Badlands National Park, USA, in 2010 and 2011. Plant species visited were determined by pollen on insect bodies and by flower species upon which insects were captured. Roles within modules (network hub, module hub, connector and peripheral, in decreasing order of network structural importance) were determined for each species. 3. Relationships demonstrated by the modularity analysis, in concert with knowledge of pollen species carried by insects, allowed us to infer effects of two invasive species on E. visheri. Sharing a module increased risk of interspecific pollen transfer to E. visheri. Control of invasive Salsola tragus, which shared a module with E. visheri, is therefore a prudent management objective, but lack of control of invasive Melilotus officinalis, which occupied a different module, is unlikely to negatively affect pollination of E. visheri. Eriogonum pauciflorum may occupy a key position in this network, supporting insects from the E. visheri module when E. visheri is less abundant. 4. Year-to-year variation in species' roles suggests management decisions must be based on observations over several years. Information on pollen deposition on stigmas would greatly strengthen inferences made from the modularity analysis. 5. Synthesis and applications: Assessing the consequences of pollination, whether at the community or individual level, is inherently time-consuming. A trade-off exists: rather than an estimate of fitness effects, the

  20. Effects of personality on territory defence in communication networks: a playback experiment with radio-tagged great tits.

    Science.gov (United States)

    Amy, Mathieu; Sprau, Philipp; de Goede, Piet; Naguib, Marc

    2010-12-07

    Individuals often differ consistently in behaviour across time and contexts, and such consistent behavioural differences are commonly described as personality. Personality can play a central role in social behaviour both in dyadic interactions and in social networks. We investigated whether explorative behaviour, as proxy of personality of territorial male great tits (Parus major), predicts their own and their neighbours' territorial responses towards simulated intruders. Several weeks prior to playback, subjects were taken from the wild to test their exploratory behaviour in a standard context in the laboratory. Exploratory behaviour provides a proxy of personality along a slow-fast explorer continuum. Upon release, males were radio-tracked and subsequently exposed to interactive playback simulating a more or a less aggressive territorial intruder (by either overlapping or alternating broadcast songs with the subjects' songs). At the same time, we radio-tracked a neighbour of the playback subject. Male vocal responses during playback and spatial movements after playback varied according to male explorative behaviour and playback treatment. Males with lower exploration scores approached the loudspeaker less, and sang more songs, shorter songs and songs with slower element rates than did males with higher exploration scores. Moreover, neighbour responses were related to the explorative behaviour of the subject receiving the playback but not to their own explorative behaviour. Our overall findings reveal for the first time how personality traits affect resource defence within a communication network providing new insights on the cause of variation in resource defence behaviour.

  1. Bladder volume estimation from electrical impedance tomography.

    Science.gov (United States)

    Schlebusch, Thomas; Nienke, Steffen; Santos, Susana Aguiar; Leonhardt, Steffen

    2013-01-01

    Ubiquitous knowledge of bladder volume is of great interest to patients whose perception of bladder volume is impaired. A promising approach to provide frequent bladder volume estimates to the patient are automatic and noninvasive measurements by electrical impedance tomography (EIT). Previous studies have shown a linear correlation of abdominal electrical impedance and bladder volume. In this article, we present two methods to extract a volume estimate from EIT measurements. One method is based on the global impedance from a reconstructed image, the second method is based on a singular value decomposition of the raw voltage measurement vector. A performance evaluation in presence of noise is performed.

  2. The Great Family Network.

    Science.gov (United States)

    Dixon, Betty L.

    1996-01-01

    Recognizing that religion can positively transform people's lives and that churches and synagogues have altruistic members with diverse abilities, the Escambia County (Florida) School District created church care teams to work with special-needs families and their schools over an extended time. Positive changes in target families are already…

  3. Great Lakes: Great Gardening.

    Science.gov (United States)

    New York Sea Grant Inst., Albany, NY.

    This folder contains 12 fact sheets designed to improve the quality of gardens near the Great Lakes. The titles are: (1) "Your Garden and the Great Lakes"; (2) "Organic Gardening"; (3) "Fruit and Vegetable Gardening"; (4) "Composting Yard Wastes"; (5) "Herbicides and Water Quality"; (6)…

  4. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  5. Bridge Network for Measuring Very Small Impedances from 4.2 to 300 degrees K with a Null-Detector Sensitivity of 10-11 Volt

    DEFF Research Database (Denmark)

    Bak, Christen Kjeldahl; Dalsgaard, Erik

    1967-01-01

    . Measurements with the bridge show that in the temperature range 300°K to 4.2°K the noise level changes from 30×10−11 V to 10−11 V without any zero shift, and as a result the lower limit for the impedance range changes from 10−6 Omega to less than 5×10−8 Omega. ©1967 The American Institute of Physics...

  6. Expectations and Outcomes of Reserve Network Performance following Re-zoning of the Great Barrier Reef Marine Park.

    Science.gov (United States)

    Emslie, Michael J; Logan, Murray; Williamson, David H; Ayling, Anthony M; MacNeil, M Aaron; Ceccarelli, Daniela; Cheal, Alistair J; Evans, Richard D; Johns, Kerryn A; Jonker, Michelle J; Miller, Ian R; Osborne, Kate; Russ, Garry R; Sweatman, Hugh P A

    2015-04-20

    Networks of no-take marine reserves (NTMRs) are widely advocated for preserving exploited fish stocks and for conserving biodiversity. We used underwater visual surveys of coral reef fish and benthic communities to quantify the short- to medium-term (5 to 30 years) ecological effects of the establishment of NTMRs within the Great Barrier Reef Marine Park (GBRMP). The density, mean length, and biomass of principal fishery species, coral trout (Plectropomus spp., Variola spp.), were consistently greater in NTMRs than on fished reefs over both the short and medium term. However, there were no clear or consistent differences in the structure of fish or benthic assemblages, non-target fish density, fish species richness, or coral cover between NTMR and fished reefs. There was no indication that the displacement and concentration of fishing effort reduced coral trout populations on fished reefs. A severe tropical cyclone impacted many survey reefs during the study, causing similar declines in coral cover and fish density on both NTMR and fished reefs. However, coral trout biomass declined only on fished reefs after the cyclone. The GBRMP is performing as expected in terms of the protection of fished stocks and biodiversity for a developed country in which fishing is not excessive and targets a narrow range of species. NTMRs cannot protect coral reefs directly from acute regional-scale disturbance but, after a strong tropical cyclone, impacted NTMR reefs supported higher biomass of key fishery-targeted species and so should provide valuable sources of larvae to enhance population recovery and long-term persistence. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Great Minds? Great Lakes!

    Science.gov (United States)

    Environmental Protection Agency, Chicago, IL. Great Lakes National Program Office.

    This booklet introduces an environmental curriculum for use in a variety of elementary subjects. The lesson plans provide an integrated approach to incorporating Great Lakes environmental issues into the subjects of history, social studies, and environmental sciences. Each of these sections contains background information, discussion points, and a…

  8. Positive impedance humidity sensors via single-component materials

    OpenAIRE

    Jingwen Qian; Zhijian Peng; Zhenguang Shen; Zengying Zhao; Guoliang Zhang; Xiuli Fu

    2016-01-01

    Resistivity-type humidity sensors have been investigated with great interest due to the increasing demands in industry, agriculture and daily life. To date, most of the available humidity sensors have been fabricated based on negative humidity impedance, in which the electrical resistance decreases as the humidity increases, and only several carbon composites have been reported to present positive humidity impedance. However, here we fabricate positive impedance humidity sensors only via sing...

  9. Impedance and Collective Effects

    CERN Document Server

    Metral, E; Rumolo, R; Herr, W

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Chapter '4 Impedance and Collective Effects' with the content: 4 Impedance and Collective Effects Introduction 4.1 Space Charge 4.2 Wake Fields and Impedances 4.3 Coherent Instabilities 4.4 Landau Damping 4.5 Two-Stream Effects (Electron Cloud and Ions) 4.6 Beam-Beam Effects 4.7 Numerical Modelling

  10. LHC Bellows Impedance Calculations

    CERN Document Server

    Dyachkov, M

    1997-01-01

    To compensate for thermal expansion the LHC ring has to accommodate about 2500 bellows which, together with beam position monitors, are the main contributors to the LHC broad-band impedance budget. In order to reduce this impedance to an acceptable value the bellows have to be shielded. In this paper we compare different designs proposed for the bellows and calculate their transverse and longitudinal wakefields and impedances. Owing to the 3D geometry of the bellows, the code MAFIA was used for the wakefield calculations; when possible the MAFIA results were compared to those obtained with ABCI. The results presented in this paper indicate that the latest bellows design, in which shielding is provided by sprung fingers which can slide along the beam screen, has impedances smaller tha those previously estimated according to a rather conservative scaling of SSC calculations and LEP measurements. Several failure modes, such as missing fingers and imperfect RF contact, have also been studied.

  11. Impedance and component heating

    CERN Document Server

    Métral, E; Mounet, N; Pieloni, T; Salvant, B

    2015-01-01

    The impedance is a complex function of frequency, which represents, for the plane under consideration (longitudinal, horizontal or vertical), the force integrated over the length of an element, from a “source” to a “test” wave, normalized by their charges. In general, the impedance in a given plane is a nonlinear function of the test and source transverse coordinates, but it is most of the time sufficient to consider only the first few linear terms. Impedances can influence the motion of trailing particles, in the longitudinal and in one or both transverse directions, leading to energy loss, beam instabilities, or producing undesirable secondary effects such as excessive heating of sensitive components at or near the chamber wall, called beam-induced RF heating. The LHC performance limitations linked to impedances encountered during the 2010-2012 run are reviewed and the currently expected situation during the HL-LHC era is discussed.

  12. The risk of disease to great apes: simulating disease spread in orang-utan (Pongo pygmaeus wurmbii and chimpanzee (Pan troglodytes schweinfurthii association networks.

    Directory of Open Access Journals (Sweden)

    Charlotte Carne

    Full Text Available All great ape species are endangered, and infectious diseases are thought to pose a particular threat to their survival. As great ape species vary substantially in social organisation and gregariousness, there are likely to be differences in susceptibility to disease types and spread. Understanding the relation between social variables and disease is therefore crucial for implementing effective conservation measures. Here, we simulate the transmission of a range of diseases in a population of orang-utans in Sabangau Forest (Central Kalimantan and a community of chimpanzees in Budongo Forest (Uganda, by systematically varying transmission likelihood and probability of subsequent recovery. Both species have fission-fusion social systems, but differ considerably in their level of gregariousness. We used long-term behavioural data to create networks of association patterns on which the spread of different diseases was simulated. We found that chimpanzees were generally far more susceptible to the spread of diseases than orang-utans. When simulating different diseases that varied widely in their probability of transmission and recovery, it was found that the chimpanzee community was widely and strongly affected, while in orang-utans even highly infectious diseases had limited spread. Furthermore, when comparing the observed association network with a mean-field network (equal contact probability between group members, we found no major difference in simulated disease spread, suggesting that patterns of social bonding in orang-utans are not an important determinant of susceptibility to disease. In chimpanzees, the predicted size of the epidemic was smaller on the actual association network than on the mean-field network, indicating that patterns of social bonding have important effects on susceptibility to disease. We conclude that social networks are a potentially powerful tool to model the risk of disease transmission in great apes, and that

  13. The LEP impedance model

    Energy Technology Data Exchange (ETDEWEB)

    Zotter, B. [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    This report describes a number of measurements and computations of the impedance of the Large Electron Positron collider LEP at CERN. The work has been performed over several years, together with D. Brandt, K. Cornelis, A. Hofmann, G. Sabbi and many others. The agreement between measurements of single bunch instabilities on the machine and computer simulations is in general excellent and gives confidence in the impedance model used. (author)

  14. Impeded Dark Matter

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, Joachim; Liu, Jia [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics,Johannes Gutenberg University,Staudingerweg 7, 55099 Mainz (Germany); Slatyer, Tracy R. [Center for Theoretical Physics, Massachusetts Institute of Technology,Cambridge, MA 02139 (United States); Wang, Xiao-Ping [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics,Johannes Gutenberg University,Staudingerweg 7, 55099 Mainz (Germany); Xue, Wei [Center for Theoretical Physics, Massachusetts Institute of Technology,Cambridge, MA 02139 (United States)

    2016-12-12

    We consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario “Impeded Dark Matter”. We demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may even be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. For positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.

  15. Effects of personality on territory defence in communication networks: a playback experiment with radio-tagged great tits

    NARCIS (Netherlands)

    Amy, M.; Sprau, P.; De Goede, P.; Naguib, M.

    2010-01-01

    Individuals often differ consistently in behaviour across time and contexts, and such consistent behavioural differences are commonly described as personality. Personality can play a central role in social behaviour both in dyadic interactions and in social networks. We investigated whether

  16. Impedance measurements of the Spallation Neutron Source extraction kicker system

    Science.gov (United States)

    Hahn, H.

    2004-10-01

    Transverse coupling impedance measurements of the Spallation Neutron Source (SNS) beam extraction system were performed and the results are here reported. The SNS beam extraction system is composed from 14 subsystems, each of which consists of a vertical kicker magnet plus a pulse forming network (PFN). Impedance bench measurements were performed on one large and one small aperture magnet, stand-alone as well as assembled with the first-article production PFN. The impedance measuring methods to cover the interesting frequency range from below 1 to 100MHz are described in considerable detail. The upper frequency range is properly covered by the conventional twin-wire method but it had to be supplemented at the low-frequency end by a direct input impedance measurement at the magnet busbar. Required modifications of the PFN to maintain the impedance budget are discussed. The total impedance estimate was finally obtained by quadratic scaling with vertical aperture from the two tested kicker subsystems.

  17. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2002-08-30

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a thin film sensor conformal with the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is capacitively coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD

  18. Implantable Impedance Plethysmography

    Directory of Open Access Journals (Sweden)

    Michael Theodor

    2014-08-01

    Full Text Available We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

  19. Nonsynchronous Noncommensurate Impedance Transformers

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Kim, K

    2012-01-01

    advantage of such transformers is that they can be constructed using sections of transmission lines with a limited variety of characteristic impedances. These transformers also provide comparatively compact size in applications where a wide transformation ratio is required. This paper presents the data...

  20. Impedance plethysmography: basic principles.

    Directory of Open Access Journals (Sweden)

    Babu J

    1990-04-01

    Full Text Available Impedance Plethysmography technique has been discussed with explanation of two compartment model and parallel conductor theory for the estimation of peripheral blood flow and stroke volume. Various methods for signal enhancement to facilitate computation of blood flow are briefly described. Source of error in the estimation of peripheral blood flow is identified and the correction has been suggested.

  1. Impedance of the Microstrip SQUID Amplifier

    Science.gov (United States)

    Therrien, Roy; Kinion, Darin; Mueck, Michael; Clarke, John

    2003-03-01

    We present measurements of the input impedance of microstrip SQUID amplifiers cooled to 4.2 K. A low-loss transmission line model fits the real and imaginary parts of this impedance quite accurately. We map the low-loss transmission line model into an equivalent parallel RLC circuit in which a resistance R, inductance L, and capacitance C are calculated from the characteristic impedance and attenuation factor determined from fits to the input impedance data. Using this equivalent RLC circuit, we model the microstrip SQUID and input network with a lumped circuit model which accurately predicts the observed gain of the amplifier. We find that the gain is maximized when the input circuit is critically matched, with the imaginary part of the input impedance summing to zero and the real part equal to the 50 ohm resistance of the coaxial input line. Work in progress is aimed at expressing the equivalent circuit parameters in terms of the device parameters. This work was supported by DOE.

  2. Observations involving broadband impedance modelling

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J.S. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    Results for single- and multi-bunch instabilities can be significantly affected by the precise model that is used for the broadband impedance. This paper discusses three aspects of broadband impedance modelling. The first is an observation of the effect that a seemingly minor change in an impedance model has on the single-bunch mode coupling threshold. The second is a successful attempt to construct a model for the high-frequency tails of an r.f. cavity. The last is a discussion of requirements for the mathematical form of an impedance which follow from the general properties of impedances. (author)

  3. Exporting embedded in culture and transnational networks around entrepreneurs

    DEFF Research Database (Denmark)

    Ashourizadeh, Shayegheh; Schøtt, Thomas

    2016-01-01

    Exporting is embedded in transnational networks and other networks around entrepreneurs. We hypothesise that exporting is constrained by networking in the private sphere, but promoted by networking in the public sphere, and benefitting especially from networking in the transnational environment....... This dynamic unfolds in the context of culture, which expectedly moderates benefit of networks for exporting. Networking for advice was surveyed in the Global Entrepreneurship Monitor in 61 societies with 52,968 entrepreneurs. Exporting greatly benefits from transnational networks around entrepreneurs and also...... from networking in the market, professions and work-place, but is impeded by networking for advice in the private sphere. Exporting is embedded in culture in the way that benefits of transnational networking for exporting are higher in secular-rational culture than in traditional culture. This study...

  4. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well......Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...

  5. Electrical impedance tomography.

    Science.gov (United States)

    Costa, Eduardo L V; Lima, Raul Gonzalez; Amato, Marcelo B P

    2009-02-01

    Electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring tool that allows real-time imaging of ventilation. The purpose of this article is to discuss the fundamentals of EIT and to review the use of EIT in critical care patients. In addition to its established role in describing the distribution of alveolar ventilation, EIT has been shown to be a useful tool to detect lung collapse and monitor lung recruitment, both regionally and on a global basis. EIT has also been used to diagnose with high sensitivity incident pneumothoraces during mechanical ventilation. Additionally, with injection of hypertonic saline as a contrast agent, it is possible to estimate ventilation/perfusion distributions. EIT is cheap, noninvasive and allows continuous monitoring of ventilation. It is gaining acceptance as a valuable monitoring tool for the care of critical patients.

  6. Great Apes

    Science.gov (United States)

    Sleeman, Jonathan M.; Cerveny, Shannon

    2014-01-01

    Anesthesia of great apes is often necessary to conduct diagnostic analysis, provide therapeutics, facilitate surgical procedures, and enable transport and translocation for conservation purposes. Due to the stress of remote delivery injection of anesthetic agents, recent studies have focused on oral delivery and/or transmucosal absorption of preanesthetic and anesthetic agents. Maintenance of the airway and provision of oxygen is an important aspect of anesthesia in great ape species. The provision of analgesia is an important aspect of the anesthesia protocol for any procedure involving painful stimuli. Opioids and nonsteroidal anti-inflammatory drugs (NSAIDs) are often administered alone, or in combination to provide multi-modal analgesia. There is increasing conservation management of in situ great ape populations, which has resulted in the development of field anesthesia techniques for free-living great apes for the purposes of translocation, reintroduction into the wild, and clinical interventions.

  7. Iterative Learning Impedance for Lower Limb Rehabilitation Robot.

    Science.gov (United States)

    Guo, Chenhui; Guo, Shuai; Ji, Jiancheng; Xi, Fengfeng

    2017-01-01

    This paper discusses the problem of squatting training of stroke patients. The main idea is to correct the patient's training trajectory through an iterative learning control (ILC) method. To obtain better rehabilitation effect, a patient will typically be required to practice a reference posture for many times, while most of active training methods can hardly keep the patients training with correct posture. Instead of the conventional ILC strategy, an impedance-based iterative learning method is proposed to regulate the impedance value dynamically and smartly which will help patients correct their posture gradually and perform better. To facilitate impedance-based ILC, we propose two objectives. The first objective is to find the suitable values of impedance based on the ILC scheme. The second objective is to search the moderate learning convergence speed and robustness in the iterative domain. The simulation and experimental results demonstrate that the performance of trajectory tracking will be improved greatly via the proposed algorithm.

  8. Impedance source power electronic converters

    CERN Document Server

    Liu, Yushan; Ge, Baoming; Blaabjerg, Frede; Ellabban, Omar; Loh, Poh Chiang

    2016-01-01

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding control methods. Presents the latest power conversion solutions that aim to advance the role of pow...

  9. Great Expectations

    NARCIS (Netherlands)

    Dickens, Charles

    2005-01-01

    One of Dickens's most renowned and enjoyable novels, Great Expectations tells the story of Pip, an orphan boy who wishes to transcend his humble origins and finds himself unexpectedly given the opportunity to live a life of wealth and respectability. Over the course of the tale, in which Pip

  10. Great Belt

    DEFF Research Database (Denmark)

    Sørensen, Carsten S.; Kristensen, Per S.; Erichsen, Lars

    1992-01-01

    This paper describes aspects of the soil investigations and geotechnical evaluations for the foundation design of the 6.6 km long Great Belt West Bridge. The gravity foundations rest predominantly on glacial tills and pre-quaternary limestone. Special investigations for assessment of the soil...

  11. Peano high-impedance surfaces

    Science.gov (United States)

    McVay, John; Hoorfar, Ahmad; Engheta, Nader

    2005-12-01

    Following our previous work on metamaterial high-impedance surfaces made of Hilbert curve inclusions, here we theoretically explore the performance of the high-impedance surfaces made of another form of space-filling curve known as the Peano curve. This metamaterial surface, formed by a two-dimensional periodic arrangement of Peano curve inclusions, is located above a conducting ground plane and is shown to exhibit a high surface impedance at certain specific frequencies. Our numerical study reveals the effect of the iteration order of the Peano curve, the surface height above the conducting ground plane, and the separation distance between adjacent inclusions.

  12. Measurement uncertainty in pulmonary vascular input impedance and characteristic impedance estimated from pulsed-wave Doppler ultrasound and pressure: clinical studies on 57 pediatric patients

    Science.gov (United States)

    Tian, Lian; Hunter, Kendall S; Kirby, K Scott; Ivy, D Dunbar; Shandas, Robin

    2010-01-01

    Pulmonary vascular input impedance better characterizes right ventricular (RV) afterload and disease outcomes in pulmonary hypertension compared to the standard clinical diagnostic, pulmonary vascular resistance (PVR). Early efforts to measure impedance were not routine, involving open-chest measurement. Recently, the use of pulsed-wave (PW) Doppler-measured velocity to non-invasively estimate instantaneous flow has made impedance measurement more practical. One critical concern remains with clinical use: the measurement uncertainty, especially since previous studies only incorporated random error. This study utilized data from a large pediatric patient population to comprehensively examine the systematic and random error contributions to the total impedance uncertainty and determined the least error prone methodology to compute impedance from among four different methods. We found that the systematic error contributes greatly to the total uncertainty and that one of the four methods had significantly smaller propagated uncertainty; however, even when this best method is used, the uncertainty can be large for input impedance at high harmonics and for the characteristic impedance modulus. Finally, we found that uncertainty in impedance between normotensive and hypertensive patient groups displays no significant difference. It is concluded that clinical impedance measurement would be most improved by advancements in instrumentation, and the best computation method is proposed for future clinical use of the input impedance. PMID:20410558

  13. A Wireless Multi-Sensor Dielectric Impedance Spectroscopy Platform

    Directory of Open Access Journals (Sweden)

    Seyed Alireza Ghaffari

    2015-09-01

    Full Text Available This paper describes the development of a low-cost, miniaturized, multiplexed, and connected platform for dielectric impedance spectroscopy (DIS, designed for in situ measurements and adapted to wireless network architectures. The platform has been tested and used as a DIS sensor node on ZigBee mesh and was able to interface up to three DIS sensors at the same time and relay the information through the network for data analysis and storage. The system is built from low-cost commercial microelectronics components, performs dielectric spectroscopy ranging from 5 kHz to 100 kHz, and benefits from an on-the-fly calibration system that makes sensor calibration easy. The paper describes the microelectronics design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the testing of the platform for in situ dielectric impedance spectroscopy applications pertaining to fertilizer sensing, water quality sensing, and touch sensing.

  14. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well......Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...

  15. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key......Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well...

  16. Damage detection technique by measuring laser-based mechanical impedance

    Science.gov (United States)

    Lee, Hyeonseok; Sohn, Hoon

    2014-02-01

    This study proposes a method for measurement of mechanical impedance using noncontact laser ultrasound. The measurement of mechanical impedance has been of great interest in nondestructive testing (NDT) or structural health monitoring (SHM) since mechanical impedance is sensitive even to small-sized structural defects. Conventional impedance measurements, however, have been based on electromechanical impedance (EMI) using contact-type piezoelectric transducers, which show deteriorated performances induced by the effects of a) Curie temperature limitations, b) electromagnetic interference (EMI), c) bonding layers and etc. This study aims to tackle the limitations of conventional EMI measurement by utilizing laser-based mechanical impedance (LMI) measurement. The LMI response, which is equivalent to a steady-state ultrasound response, is generated by shooting the pulse laser beam to the target structure, and is acquired by measuring the out-of-plane velocity using a laser vibrometer. The formation of the LMI response is observed through the thermo-mechanical finite element analysis. The feasibility of applying the LMI technique for damage detection is experimentally verified using a pipe specimen under high temperature environment.

  17. Reactive power optimization strategy considering analytical impedance ratio

    Science.gov (United States)

    Wu, Zhongchao; Shen, Weibing; Liu, Jinming; Guo, Maoran; Zhang, Shoulin; Xu, Keqiang; Wang, Wanjun; Sui, Jinlong

    2017-05-01

    In this paper, considering the traditional reactive power optimization cannot realize the continuous voltage adjustment and voltage stability, a dynamic reactive power optimization strategy is proposed in order to achieve both the minimization of network loss and high voltage stability with wind power. Due to the fact that wind power generation is fluctuant and uncertain, electrical equipments such as transformers and shunt capacitors may be operated frequently in order to achieve minimization of network loss, which affect the lives of these devices. In order to solve this problem, this paper introduces the derivation process of analytical impedance ratio based on Thevenin equivalent. Thus, the multiple objective function is proposed to minimize the network loss and analytical impedance ratio. Finally, taking the improved IEEE 33-bus distribution system as example, the result shows that the movement of voltage control equipment has been reduced and network loss increment is controlled at the same time, which proves the applicable value of this strategy.

  18. Great Lakes

    Science.gov (United States)

    Edsall, Thomas A.; Mac, Michael J.; Opler, Paul A.; Puckett Haecker, Catherine E.; Doran, Peter D.

    1998-01-01

    The Great Lakes region, as defined here, includes the Great Lakes and their drainage basins in Minnesota, Wisconsin, Illinois, Indiana, Ohio, Pennsylvania, and New York. The region also includes the portions of Minnesota, Wisconsin, and the 21 northernmost counties of Illinois that lie in the Mississippi River drainage basin, outside the floodplain of the river. The region spans about 9º of latitude and 20º of longitude and lies roughly halfway between the equator and the North Pole in a lowland corridor that extends from the Gulf of Mexico to the Arctic Ocean.The Great Lakes are the most prominent natural feature of the region (Fig. 1). They have a combined surface area of about 245,000 square kilometers and are among the largest, deepest lakes in the world. They are the largest single aggregation of fresh water on the planet (excluding the polar ice caps) and are the only glacial feature on Earth visible from the surface of the moon (The Nature Conservancy 1994a).The Great Lakes moderate the region’s climate, which presently ranges from subarctic in the north to humid continental warm in the south (Fig. 2), reflecting the movement of major weather masses from the north and south (U.S. Department of the Interior 1970; Eichenlaub 1979). The lakes act as heat sinks in summer and heat sources in winter and are major reservoirs that help humidify much of the region. They also create local precipitation belts in areas where air masses are pushed across the lakes by prevailing winds, pick up moisture from the lake surface, and then drop that moisture over land on the other side of the lake. The mean annual frost-free period—a general measure of the growing-season length for plants and some cold-blooded animals—varies from 60 days at higher elevations in the north to 160 days in lakeshore areas in the south. The climate influences the general distribution of wild plants and animals in the region and also influences the activities and distribution of the human

  19. GREAT optics

    Science.gov (United States)

    Wagner-Gentner, Armin; Graf, Urs U.; Philipp, Martin; Rabanus, David; Stutzki, Jürgen

    2004-10-01

    The German REceiver for Astronomy at Terahertz frequencies (GREAT) is a first generation PI instrument for the SOFIA telescope, developed by a collaboration between the MPIfR, KOSMA, DLR, and the MPAe. The first three institutes each contribute one heterodyne receiver channel to operate at 1.9, 2.7 and 4.7 THz, respectively. A later addition of a e.g. 1.4 THz channel is planned. The GREAT instrument is developed to carry two cryostats at once. That means that any two of the three frequencies can be observed simultaneously. Therefore, we need to be able to quickly exchange the optics benches, the local oscillator (LO) subsystems, and the cryostats containing the mixer devices. This demands a high modularity and flexibility of our receiver concept. Our aim is to avoid the need for realignment when swapping receiver channels. After an overview of the common GREAT optics, a detailed description of several parts (optics benches, calibration units, diplexer, focal plane imager) is given. Special emphasis is given to the LO optics of the KOSMA 1.9 THz channel, because its backward wave oscillator has an astigmatic output beam profile, which has to be corrected for. We developed astigmatic off-axis mirrors to compensate this astigmatism. The mirrors are manufactured in-house on a 5 axis CNC milling machine. We use this milling machine to obtain optical components with highest surface accuracy (about 5 microns) appropriate for these wavelengths. Based on the CNC machining capabilities we present our concept of integrated optics, which means to manufacture optical subsystems monolithically. The optics benches are located on three point mounts, which in conjunction with the integrated optics concept ensure the required adjustment free optics setup.

  20. Barriers, Facilitators and Priorities for Implementation of WHO Maternal and Perinatal Health Guidelines in Four Lower-Income Countries: A GREAT Network Research Activity

    Science.gov (United States)

    Vogel, Joshua P.; Moore, Julia E.; Timmings, Caitlyn; Khan, Sobia; Khan, Dina N.; Defar, Atkure; Hadush, Azmach; Minwyelet Terefe, Marta; Teshome, Luwam; Ba-Thike, Katherine; Than, Kyu Kyu; Makuwani, Ahmad; Mbaruku, Godfrey; Mrisho, Mwifadhi; Mugerwa, Kidza Yvonne; Puchalski Ritchie, Lisa M.; Rashid, Shusmita; Straus, Sharon E.; Gülmezoglu, A. Metin

    2016-01-01

    Background Health systems often fail to use evidence in clinical practice. In maternal and perinatal health, the majority of maternal, fetal and newborn mortality is preventable through implementing effective interventions. To meet this challenge, WHO’s Department of Reproductive Health and Research partnered with the Knowledge Translation Program at St. Michael’s Hospital (SMH), University of Toronto, Canada to establish a collaboration on knowledge translation (KT) in maternal and perinatal health, called the GREAT Network (Guideline-driven, Research priorities, Evidence synthesis, Application of evidence, and Transfer of knowledge). We applied a systematic approach incorporating evidence and theory to identifying barriers and facilitators to implementation of WHO maternal heath recommendations in four lower-income countries and to identifying implementation strategies to address these. Methods We conducted a mixed-methods study in Myanmar, Uganda, Tanzania and Ethiopia. In each country, stakeholder surveys, focus group discussions and prioritization exercises were used, involving multiple groups of health system stakeholders (including administrators, policymakers, NGOs, professional associations, frontline healthcare providers and researchers). Results Despite differences in guideline priorities and contexts, barriers identified across countries were often similar. Health system level factors, including health workforce shortages, and need for strengthened drug and equipment procurement, distribution and management systems, were consistently highlighted as limiting the capacity of providers to deliver high-quality care. Evidence-based health policies to support implementation, and improve the knowledge and skills of healthcare providers were also identified. Stakeholders identified a range of tailored strategies to address local barriers and leverage facilitators. Conclusion This approach to identifying barriers, facilitators and potential strategies for

  1. Multi-EM27/SUN Total Carbon Column Observing Network (TCCON) Comparison at the Southern Great Plains Site Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Parker, H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hedelius, J. [California Inst. of Technology (CalTech), Pasadena, CA (United States)

    2016-04-01

    During the summer of 2015, a field campaign took place to help characterize off-the-shelf portable solar-viewing Fourier Transform Spectrometer (FTS) instruments (EM27/SUN). These instruments retrieve greenhouse gas (GHG) abundances from direct solar spectra. A focus of this campaign was to test possible dependence on different atmospheric conditions. Along with the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) site in Oklahoma, experiments were conducted in Pasadena, California; Park Falls, Wisconsin; and the Armstrong Flight Research Center (AFRC), California. These locations are home to instruments in the Total Column Carbon Observing Network (TCCON). TCCON measurements were used as standards for the portable (EM27/SUN) measurements. Comparisons between the two types of instruments are crucial in the attempt to use the portable instruments to broaden the capabilities of GHG measurements for monitoring, reporting, and verification of carbon in the atmosphere. This campaign was aimed at testing the response of the portable FTS to different atmospheric conditions both local and regional. Measurements made at ARM SGP provided data in an agricultural environment with a relatively clean atmosphere with respect to pollution. Due to the homogeneity of the region surrounding Lamont, Oklahoma, portable FTS measurements were less effected by large changes in column GHG abundances from air mass movement between regions. These conditions aided in characterizing potential artificial solar zenith angle dependence of the retrievals. Data collected under atmospheric conditions at ARM SGP also provide for the analysis of cloud interference on solar spectra. In situ measurements were also made using a Picarro isotopic methane analyzer to determine surface-level in situ GHG concentrations and possible influences due to local agriculture and nearby towns. Data collected in this campaign have been presented

  2. Impedance measurements of the Spallation Neutron Source extraction kicker system

    Directory of Open Access Journals (Sweden)

    H. Hahn

    2004-10-01

    Full Text Available Transverse coupling impedance measurements of the Spallation Neutron Source (SNS beam extraction system were performed and the results are here reported. The SNS beam extraction system is composed from 14 subsystems, each of which consists of a vertical kicker magnet plus a pulse forming network (PFN. Impedance bench measurements were performed on one large and one small aperture magnet, stand-alone as well as assembled with the first-article production PFN. The impedance measuring methods to cover the interesting frequency range from below 1 to 100 MHz are described in considerable detail. The upper frequency range is properly covered by the conventional twin-wire method but it had to be supplemented at the low-frequency end by a direct input impedance measurement at the magnet busbar. Required modifications of the PFN to maintain the impedance budget are discussed. The total impedance estimate was finally obtained by quadratic scaling with vertical aperture from the two tested kicker subsystems.

  3. Impedance studies - Part 4: The APS impedance budget

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-07-01

    This note will wrap up the numerical results that were obtained in our calculations of the wake potentials, the loss factors, and the impedances for a variety of structures in the APS storage ring. It consists of five sections and one appendix. Section 1 is an introduction. Section 2 summarizes the hand calculations. The computer calculations are the subject 1 of Section 3. Section 4 discusses several tests in our numerical methods. Section 5 presents the APS impedance budget, along with some discussion. The appendix contains the figures of the structures, the longitudinal/transverse wake potentials and the real/imaginary part of the impedances of various sorts of geometries that have been included in the budget.

  4. Battery impedance spectroscopy using bidirectional grid connected ...

    Indian Academy of Sciences (India)

    Keywords. Impedance spectroscopy; grid connection; battery converter; state of charge; health monitoring ... impedance by frequency sweep, avoiding transients. The measured impedance has been compared to that from a commercially available impedance measurement equipment and is shown to have a good match.

  5. Plasmonic Imaging of Electrochemical Impedance.

    Science.gov (United States)

    Yuan, Liang; Tao, Nongjian; Wang, Wei

    2017-06-12

    Electrochemical impedance spectroscopy (EIS) measures the frequency spectrum of an electrochemical interface to resist an alternating current. This method allows label-free and noninvasive studies on interfacial adsorption and molecular interactions and has applications in biosensing and drug screening. Although powerful, traditional EIS lacks spatial resolution or imaging capability, hindering the study of heterogeneous electrochemical processes on electrodes. We have recently developed a plasmonics-based electrochemical impedance technique to image local electrochemical impedance with a submicron spatial resolution and a submillisecond temporal resolution. In this review, we provide a systematic description of the theory, instrumentation, and data analysis of this technique. To illustrate its present and future applications, we further describe several selected samples analyzed with this method, including protein microarrays, two-dimensional materials, and single cells. We conclude by summarizing the technique's unique features and discussing the remaining challenges and new directions of its application.

  6. Acoustic impedances of ear canals measured by impedance tube

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2007-01-01

    During hearing sensitivity tests, the sound field is commonly generated by an earphone placed on a subject ear. One of the factors that can affect the sound transmission in the ear is the acoustic impedance of the ear canal. Its importance is related to the contribution of other elements involved...

  7. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...... control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well...... as different industrial applications. Provides an overview of existing challenges, solutions and future trends. Supported by calculation examples, simulation models and results....

  8. A Frequency-Tracking and Impedance-Matching Combined System for Robust Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Yanting Luo

    2017-01-01

    Full Text Available One of the greatest challenges to power embedded devices using magnetically coupled resonant wireless power transfer (WPT system is that the amount of power delivered to the load is very sensitive to load impedance variations. Previous adaptive impedance-matching (IM technologies have drawbacks because adding IM networks, relay coils, or other compensating components in the receiver-side will significantly increase the receiver size. In this paper, a novel frequency-tracking and impedance-matching combined system is proposed to improve the robustness of wireless power transfer for embedded devices. The characteristics of the improved WPT system are investigated theoretically based on the two-port network model. Simulation and experimental studies are carried out to validate the proposed system. The results suggest that the frequency-tracking and impedance-matching combined WPT system can quickly find the best matching points and maintain high power transmission efficiency and output power when the load impedance changes.

  9. Input Impedance of the Microstrip SQUID Amplifier

    Science.gov (United States)

    Kinion, Darin; Clarke, John

    2008-03-01

    We present measurements of the complex scattering parameters of microstrip SQUID amplifiers (MSA) cooled to 4.2 K. The input of the MSA is a microstrip transmission line in the shape of a square spiral coil surrounding the hole in the SQUID washer that serves as the ground plane. The input impedance is found by measuring the reverse scattering parameter (S11) and is described well by a low-loss transmission line model. We map the low-loss transmission line model into an equivalent parallel RLC circuit in which a resistance R, inductance L, and capacitance C are calculated from the resonant frequency, characteristic impedance and attenuation factor. Using this equivalent RLC circuit, we model the MSA and input network with a lumped circuit model that accurately predicts the observed gain given by the forward scattering parameter (S21). We will summarize results for different coil geometries and terminations as well as SQUID bias conditions. A portion of this work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory in part under Contract W-7405-Eng-48 and in part under Contract DE-AC52-07NA27344 and by Lawrence Berkeley National Laboratory under Contract No. DE-AC02-05CH11231.

  10. Electrochemical properties and electrochemical impedance ...

    African Journals Online (AJOL)

    Polypyrrole (PPy) films of different thickness were characterized by electrochemical impedance spectroscopy (EIS) measurements in acetonitrile and aqueous solutions, containing 0.1 M NaClO4 or sodium dodecylsulfate as the dopant. The PPy films were electrochemically deposited on Pt, and their electrochemical ...

  11. Small Signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2014-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterized by the mechanical resonance between the mass of the diaphragm and the compliance of its suspension which vary...

  12. Modelling the distance impedance of protest attendance

    Science.gov (United States)

    Traag, V. A.; Quax, R.; Sloot, P. M. A.

    2017-02-01

    Protesters are usually young, relatively well educated, middle class people that are politically engaged. But where do protesters come from? We here show, based on mobile phone data, that distance is an important impedance to protest attendance. Most protesters come from nearby regions, suggesting distance forms an obstacle to participation. Although this effect can be partly explained by social network effects, which show similar spatial dependencies, an effect of distance remains. This suggests distance still acts as an obstacle to participation, although it may also be that long-range contacts are less effective for recruitment. Face-to-face contacts seem more important in spreading protests through earlier participants, whereas central recruitment works better by telephone. Our results are important for understanding processes of recruitment.

  13. Great cities look small

    CERN Document Server

    Sim, Aaron; Barahona, Mauricio; Stumpf, Michael P H

    2015-01-01

    Great cities connect people; failed cities isolate people. Despite the fundamental importance of physical, face-to-face social-ties in the functioning of cities, these connectivity networks are not explicitly observed in their entirety. Attempts at estimating them often rely on unrealistic over-simplifications such as the assumption of spatial homogeneity. Here we propose a mathematical model of human interactions in terms of a local strategy of maximising the number of beneficial connections attainable under the constraint of limited individual travelling-time budgets. By incorporating census and openly-available online multi-modal transport data, we are able to characterise the connectivity of geometrically and topologically complex cities. Beyond providing a candidate measure of greatness, this model allows one to quantify and assess the impact of transport developments, population growth, and other infrastructure and demographic changes on a city. Supported by validations of GDP and HIV infection rates ac...

  14. Bifurcation behaviors of synchronized regions in logistic map networks with coupling delay

    Science.gov (United States)

    Tang, Longkun; Wu, Xiaoqun; Lü, Jinhu; Lu, Jun-an

    2015-03-01

    Network synchronized regions play an extremely important role in network synchronization according to the master stability function framework. This paper focuses on network synchronous state stability via studying the effects of nodal dynamics, coupling delay, and coupling way on synchronized regions in Logistic map networks. Theoretical and numerical investigations show that (1) network synchronization is closely associated with its nodal dynamics. Particularly, the synchronized region bifurcation points through which the synchronized region switches from one type to another are in good agreement with those of the uncoupled node system, and chaotic nodal dynamics can greatly impede network synchronization. (2) The coupling delay generally impairs the synchronizability of Logistic map networks, which is also dominated by the parity of delay for some nodal parameters. (3) A simple nonlinear coupling facilitates network synchronization more than the linear one does. The results found in this paper will help to intensify our understanding for the synchronous state stability in discrete-time networks with coupling delay.

  15. Electrical Impedance Tomography of Breast Cancer

    National Research Council Canada - National Science Library

    Muftuller, L

    2003-01-01

    ... or malignant ft has been shown that cancer cells exhibit altered local electrical impedance. However, existing technology to measure the electrical impedance of the breast relies on a device that has poor spatial resolution...

  16. Electrical Impedance Tomography of Breast Cancer

    National Research Council Canada - National Science Library

    Muftuler, L. T

    2005-01-01

    .... It has been shown that cancer cells exhibit altered local electrical impedance. However, existing technology to measure the electrical impedance of the breast relies on a device that has poor spatial resolution...

  17. The quantum Hall impedance standard

    Science.gov (United States)

    Schurr, J.; Kučera, J.; Pierz, K.; Kibble, B. P.

    2011-02-01

    Alternating current measurements of double-shielded quantum Hall devices have revealed a fascinating property of which only a quantum effect is capable: it can detect its own frequency dependence and convert it to a current dependence which can be used to eliminate both of them. According to an experimentally verified model, the residual frequency dependence is smaller than the measuring uncertainty of 1.3 × 10-9 kHz-1. In this way, a highly precise quantum standard of impedance can be established, without having to correct for any calculated frequency dependence and without the need for any artefact with a calculated frequency dependence. Nothing else like that is known to us and we hope that our results encourage other national metrology institutes to also apply it to impedance metrology and further explore its beautiful properties.

  18. Tapping mode microwave impedance microscopy

    KAUST Repository

    Lai, K.

    2009-01-01

    We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results. © 2009 American Institute of Physics.

  19. Impedance Spectroscopy of Dielectrics and Electronic Conductors

    DEFF Research Database (Denmark)

    Bonanos, Nikolaos; Pissis, Polycarpos; Macdonald, J. Ross

    2013-01-01

    Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property, such as admi......Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property...

  20. Impedance-matched Marx generators

    Directory of Open Access Journals (Sweden)

    W. A. Stygar

    2017-04-01

    Full Text Available We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs. The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with LC time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22-Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19-Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

  1. Impedance-matched Marx generators

    Science.gov (United States)

    Stygar, W. A.; LeChien, K. R.; Mazarakis, M. G.; Savage, M. E.; Stoltzfus, B. S.; Austin, K. N.; Breden, E. W.; Cuneo, M. E.; Hutsel, B. T.; Lewis, S. A.; McKee, G. R.; Moore, J. K.; Mulville, T. D.; Muron, D. J.; Reisman, D. B.; Sceiford, M. E.; Wisher, M. L.

    2017-04-01

    We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs). The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with L C time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22 -Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19 -Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

  2. A case study of the Great Plains low-level jet using wind profiler network data and a high resolution mesoscale model

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, S.; Fast, J.D.; Bian, X.; Stage, S. [Pacific Northwest National Lab., Richland, WA (United States)] [and others

    1996-04-01

    The Great Plains low-level jet (LLJ) has important effects on the life cycle of clouds and on radiative and surface heat and moisture fluxes at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) site. This diurnal phenomenon governs the transport and convergence of low-level moisture into the region and often leads to the development of clouds and precipitation. A full understanding of the life cycle of clouds at the SGP CART site and their proper representation in single column and global climate models cannot be obtained without an improved understanding of this important phenomenon.

  3. Electrical Impedance Tomography of Breast Cancer

    Science.gov (United States)

    2004-06-01

    Algorithm in Magnetic Resonance Electrical Impedance Tomography (MREIT): Phantom Experiment for Static Resistivity Images," IEEE Trans. on Medical Imaging...Tomography MREIT: Magnetic Resonance Electrical Impedance Tomography FEM: Finite Element Method EIS: Electrical Impedance Scanning OPAMP : Operational...transconductance amplifier was designed and built using three LM741 OPAMP circuits to convert the voltage from the signal generator into a current

  4. A spatial impedance controller for robotic manipulation

    NARCIS (Netherlands)

    Fasse, Ernest D.; Fasse, Ernest; Broenink, Johannes F.

    1997-01-01

    Mechanical impedance is the dynamic generalization of stiffness, and determines interactive behavior by definition. Although the argument for explicitly controlling impedance is strong, impedance control has had only a modest impact on robotic manipulator control practice. This is due in part to the

  5. A compact broadband nonsynchronous noncommensurate impedance transformer

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Kim, Kseniya; Narenda, Kumar

    2012-01-01

    Nonsynchronous noncommensurate impedance transformers consist of a combination of high‐ and low‐impedance transmission lines. High‐impedance lines have narrow tracks in strip and microstrip technology, which allows for high flexibility and miniaturization of the layout in comparison to the tradit......Nonsynchronous noncommensurate impedance transformers consist of a combination of high‐ and low‐impedance transmission lines. High‐impedance lines have narrow tracks in strip and microstrip technology, which allows for high flexibility and miniaturization of the layout in comparison...... to the traditional tapered line transformers. This flexibility of the broadband nonsynchronous noncommensurate impedance transformers is experimentally demonstrated in this article allowing the length reduction by almost three times. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:1832–1835, 2012; View...

  6. Declarative Networking

    CERN Document Server

    Loo, Boon Thau

    2012-01-01

    Declarative Networking is a programming methodology that enables developers to concisely specify network protocols and services, which are directly compiled to a dataflow framework that executes the specifications. Declarative networking proposes the use of a declarative query language for specifying and implementing network protocols, and employs a dataflow framework at runtime for communication and maintenance of network state. The primary goal of declarative networking is to greatly simplify the process of specifying, implementing, deploying and evolving a network design. In addition, decla

  7. Error Correction of EMTDC Line and Cable Series Impedance Calculations Compared to Traditional Methods

    DEFF Research Database (Denmark)

    Sørensen, Stefan; Nielsen, Hans Ove

    2002-01-01

    In this paper we present comparison of different line and cable series impedance calculation methods, where the correction of a discovered PSCAD/EMIDC v.3.0.8 calculation error of the cable series impedance results n deviation under 0.1% instead of the previous method which gave approximately 10%......% deviation to other methods. The correction is done by adjusting he earth return path impedance for the cable model, and will thereby form the basis for a future comparison with measured data from a real full scale earth fault experiment on a mixed line and cable network.......In this paper we present comparison of different line and cable series impedance calculation methods, where the correction of a discovered PSCAD/EMIDC v.3.0.8 calculation error of the cable series impedance results n deviation under 0.1% instead of the previous method which gave approximately 10...

  8. Impedance spectroscopy of food mycotoxins

    Science.gov (United States)

    Bilyy, Oleksandr I.; Yaremyk, Roman Ya.; Kotsyumbas, Ihor Ya.; Kotsyumbas, Halyna I.

    2012-01-01

    A new analytical method of high-selective detection of mycotoxins in food and feed are considered. A method is based on optical registration the changes of conduct of the electric polarized bacterial agents in solution at the action of the external gradient electric fields. Measuring are conducted in integrated electrode-optical cuvette of the special construction, which provides the photometric analysis of forward motion of the objects registration in liquid solution under act of the enclosed electric field and simultaneous registration of kinetics of change of electrical impedance parameters solution and electrode system.

  9. Impedance Discontinuity Reduction Between High-Speed Differential Connectors and PCB Interfaces

    Science.gov (United States)

    Navidi, Sal; Agdinaoay, Rodell; Walter, Keith

    2013-01-01

    High-speed serial communication (i.e., Gigabit Ethernet) requires differential transmission and controlled impedances. Impedance control is essential throughout cabling, connector, and circuit board construction. An impedance discontinuity arises at the interface of a high-speed quadrax and twinax connectors and the attached printed circuit board (PCB). This discontinuity usually is lower impedance since the relative dielectric constant of the board is higher (i.e., polyimide approx. = 4) than the connector (Teflon approx. = 2.25). The discontinuity can be observed in transmit or receive eye diagrams, and can reduce the effective link margin of serial data networks. High-speed serial data network transmission improvements can be made at the connector-to-board interfaces as well as improving differential via hole impedances. The impedance discontinuity was improved by 10 percent by drilling a 20-mil (approx. = 0.5-mm) hole in between the pin of a differential connector spaced 55 mils (approx. = 1.4 mm) apart as it is attached to the PCB. The effective dielectric constant of the board can be lowered by drilling holes into the board material between the differential lines in a quadrax or twinax connector attachment points. The differential impedance is inversely proportional to the square root of the relative dielectric constant. This increases the differential impedance and thus reduces the above described impedance discontinuity. The differential via hole impedance can also be increased in the same manner. This technique can be extended to multiple smaller drilled holes as well as tapered holes (i.e., big in the middle followed by smaller ones diagonally).

  10. Small Signal Modeling and Comprehensive Analysis of Magnetically Coupled Impedance Source Converters

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Siwakoti, Yam Prasad; Blaabjerg, Frede

    2016-01-01

    Magnetically coupled impedance-source (MCIS) networks are recently introduced impedance networks intended for various high-boost applications. It employs coupled magnetic in the circuit to achieve higher voltage gain. Various MCIS networks have been proposed in the literature for myriad......-signal derivation is demonstrated for pulse width modulation (PWM) MCIS converters and it is shown that the derived transfer functions can simply be applied to Y-source, Γ-source, and T-source impedance networks. Various transfer functions for capacitor voltage, output voltage, magnetizing current, input and output...... applications; however, due to effective role of system modeling in the closed-loop controller design, this paper is allocated to small-signal modeling and analysis of MCIS converters. The modeling is performed by means of the circuit averaging and averaged switch technique. A generalized small...

  11. Small Signal Modeling and Comprehensive Analysis of Magnetically Coupled Impedance Source Converters

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Siwakoti, Yam Prasad; Blaabjerg, Frede

    2016-01-01

    applications; however, due to effective role of system modeling in the closed-loop controller design, this paper is allocated to small-signal modeling and analysis of MCIS converters. The modeling is performed by means of the circuit averaging and averaged switch technique. A generalized small......Magnetically coupled impedance-source (MCIS) networks are recently introduced impedance networks intended for various high-boost applications. It employs coupled magnetic in the circuit to achieve higher voltage gain. Various MCIS networks have been proposed in the literature for myriad......-signal derivation is demonstrated for pulse width modulation (PWM) MCIS converters and it is shown that the derived transfer functions can simply be applied to Y-source, Γ-source, and T-source impedance networks. Various transfer functions for capacitor voltage, output voltage, magnetizing current, input and output...

  12. Impedance matching with an adjustable segmented transmission line.

    Science.gov (United States)

    Qian, Chunqi; Brey, William W

    2009-07-01

    A capability for impedance matching between the RF probe and the spectrometer is a standard requirement for NMR. Both lumped element and branched transmission line methods are widely used for this purpose. Here, we propose to use the segmented transmission line structure which is well known in wireless communications. It relies upon reflections between transmission lines of different characteristic impedances that are serially connected to match the impedance of a coil or resonator to the characteristic impedance of the NMR spectrometer. In our implementation, two quarter wave length dielectric slugs are placed within a coaxial transmission line. Adjustment of the positions of the slugs allows the variable tuning and matching needed for NMR probes, eliminating the need for variable capacitors and inductors. As a demonstration of the usefulness of this approach, we have incorporated a variable segmented transmission line into a home-built Variable Angle Spinning probe. Finally, we discuss the range of possible application for segmented transmission line networks in NMR probe design.

  13. A digital controlled PV-inverter with grid impedance estimation for ENS detection

    DEFF Research Database (Denmark)

    Asiminoaei, Lucian; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    in dispersed power generation networks. For instance, the knowledge of the utility impedance at the fundamental frequency can be used to detect a utility failure. A PV-inverter with this feature can anticipate a possible network problem and decouple it in time. This paper describes the digital implementation...

  14. A Family of Cost-Effective Magnetically-Coupled Impedance Source Inverters

    DEFF Research Database (Denmark)

    Li, Kerui; Yang, Yongheng; Qin, Zian

    2017-01-01

    This paper presents a family of cost-effective magnetically-coupled impedance source inverters for renewable energy systems. The inverters are derived from magnetically-coupled impedance source networks, featuring low cost and no ground leakage current when used in PV system. The numbers of requi......This paper presents a family of cost-effective magnetically-coupled impedance source inverters for renewable energy systems. The inverters are derived from magnetically-coupled impedance source networks, featuring low cost and no ground leakage current when used in PV system. The numbers...... of required semiconductor switches is reduced. More important, the elimination of leakage currents makes it particularly suitable for high-efficiency photovoltaic (PV) applications. A comparison among prior-art PV inverters is then performed. The Performances of the inverters are evaluated analytically...

  15. Characteristic Impedance of a Microstrip-Like Interconnect Line in Presence of Ground Plane Aperture

    Directory of Open Access Journals (Sweden)

    Rohit Sharma

    2007-01-01

    Full Text Available We propose new empirical expressions for the characteristic impedance of a microstrip-like interconnect line in presence of ground plane aperture. The existing characteristic impedance expressions are modified so as to include the effect of the ground plane aperture. The variation in the characteristic impedance vis-à-vis the aperture size is established. The proposed expressions are general and valid for a range of dielectric materials concerning MICs, RFICs, and PCBs. The results are validated by measurements performed on a vector network analyzer.

  16. A Review of Galvanically Isolated Impedance-Source DC–DC Converters

    DEFF Research Database (Denmark)

    Chub, Andrii; Vinnikov, Dmitri; Blaabjerg, Frede

    2016-01-01

    Impedance-source converters, an emerging technology in electric energy conversion, overcome limitations of conventional solutions by the use of specific impedance-source networks. Focus of this paper is on the topologies of galvanically isolated impedance-source dc-dc converters. These converters...... isolated dc-dc converters according to the element that transfers energy from the input to the output: a transformer, a coupled inductor, or their combination. This classification reveals advantages and disadvantages, as well as a wide space for further research. This paper also outlines the most promising...

  17. Pumping slots: impedances and power losses

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. [Maryland Univ., College Park, MD (United States). Dept. of Physics

    1996-08-01

    Contributions of pumping slots to the beam coupling impedances and power losses in a B-factory ring are considered. While their leading contribution is to the inductive impedance, for high-intensity machines with short bunches like e{sup +}e{sup -} B-factories the real part of the impedance and related loss factors are also important. Using an analytical approach we calculate the coupling impedances and loss factors due to slots in a ring with an arbitrary cross section of the vacuum chamber. Effects of the slot tilt on the beam impedance are also considered, and restrictions on the tilt angle are derived from limitations on the impedance increase. The power leakage through the slots is discussed briefly. The results are applied to the KEK B-factory. (author)

  18. High frequency impedances in European XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Dohlus, Martin; Zagorodnov, Igor; Zagorodnova, Olga

    2010-06-15

    The method of the optical approximation is used to estimate the high frequency impedances of different vacuum chamber transitions of the European XFEL beam line. The approximations of the longitudinal impedances are obtained in terms of simple one-dimensional integrals. The transverse impedances are written in analytical closed form. The analytical results are compared with the results obtained by numerical solution of Maxwell's equations. (orig.)

  19. Electrical impedance tomography of electrolysis.

    Science.gov (United States)

    Meir, Arie; Rubinsky, Boris

    2015-01-01

    The primary goal of this study is to explore the hypothesis that changes in pH during electrolysis can be detected with Electrical Impedance Tomography (EIT). The study has relevance to real time control of minimally invasive surgery with electrolytic ablation. To investigate the hypothesis, we compare EIT reconstructed images to optical images acquired using pH-sensitive dyes embedded in a physiological saline agar gel phantom treated with electrolysis. We further demonstrate the biological relevance of our work using a bacterial E.Coli model, grown on the phantom. The results demonstrate the ability of EIT to image pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E.coli model. The results are promising, and invite further experimental explorations.

  20. Electrical impedance tomography of electrolysis.

    Directory of Open Access Journals (Sweden)

    Arie Meir

    Full Text Available The primary goal of this study is to explore the hypothesis that changes in pH during electrolysis can be detected with Electrical Impedance Tomography (EIT. The study has relevance to real time control of minimally invasive surgery with electrolytic ablation. To investigate the hypothesis, we compare EIT reconstructed images to optical images acquired using pH-sensitive dyes embedded in a physiological saline agar gel phantom treated with electrolysis. We further demonstrate the biological relevance of our work using a bacterial E.Coli model, grown on the phantom. The results demonstrate the ability of EIT to image pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E.coli model. The results are promising, and invite further experimental explorations.

  1. Impedance-based monitoring for tissue engineering applications

    DEFF Research Database (Denmark)

    Canali, Chiara; Heiskanen, Arto; Martinsen, Ø.G.

    2015-01-01

    Impedance is a promising technique for sensing the overall process of tissue engineering. Different electrode configurations can be used to characterize the scaffold that supports cell organization in terms of hydrogel polymerization and degree of porosity, monitoring cell loading, cell prolifera......Impedance is a promising technique for sensing the overall process of tissue engineering. Different electrode configurations can be used to characterize the scaffold that supports cell organization in terms of hydrogel polymerization and degree of porosity, monitoring cell loading, cell...... of the medium filling the pores of the scaffold can serve as the basis for porosity determination using Archie’s law. Different networks of structured or random channels and degree of porosity can be detected. In addition, by combining a number of two-, three- and four-terminal (2T, 3T, 4T) configurations...

  2. Research on the modeling of the impedance match bond at station track circuit in Chinese high-speed railway

    Directory of Open Access Journals (Sweden)

    Shiwu Yang

    2015-11-01

    Full Text Available Frequency-shift keying audio jointless track circuit is used in high-speed railway in China. However, within the station, track circuit with mechanical insulation is applied. In complex circuit network of electrified railway station, impedance match bond is designed to ensure the normal operation of the track circuit and the protection of strong traction current interference. As a combination of strong and weak electricity components of track circuit, impedance match bond is both the part of the loop of the traction current and the part of the transmission line of track circuit, playing a very critical role in the electrified railway. The structure of impedance match bond is more complex than traditional impedance transformer, including the transformer with larger air-gap, LC resonance circuit for power frequency filtering, and components to enhance the signal frequency. Modeling on impedance match bond and study about the four-terminal network parameters of impedance match bond are in favor of the following two aspects: modeling of the overall traction current and calculation of track circuit working condition. By applying the transformer equivalent circuit model and combination of testing and calculation, the accurate model of impedance match bond is constructed and verified. Finally, for ease of track circuit calculation, four-terminal network model of impedance match bond under different signal carrier frequencies is presented.

  3. An RF powering system with adaptive impedance matching for individual health monitoring applications.

    Science.gov (United States)

    Zemin Liu; Yu-Pin Hsu; Hella, Mona M

    2016-08-01

    This paper presents a high-efficiency RF powering system, suitable for individual health monitoring applications. The system is composed of an antenna, an impedance matching network, and a two-stage full-wave RF-DC rectifier. A novel tuning mechanism is proposed to automatically adjust the impedance of the matching network. This mechanism can effectively improve the power efficiency of the system by 47% compared to the case without tuning. For the adaptive impedance, only a 5-bits binary weighted capacitor bank is required in the matching network. The complete system, designed in a standard 0.13μm CMOS technology, converts a -6dBm 915MHz RF signal to a 1.7V DC voltage with an output current of 85μA. The simulated maximum power efficiency of the complete RF harvester is 66%.

  4. Very high precision survey equipment for great distances Surface surveys used to map out the surface network and the tunnelling machines then gyroscopically steered underground.

    CERN Multimedia

    1983-01-01

    At the beginning of the 1980s, CERN embarked on the enormous Large Electron-Positron Collider construction project. The excavation of the 27-kilometre LEP tunnel was a huge technical challenge. The tunnel-boring machines excavated the tunnel in 3.3 km octants and had to be operated with extraordinary precision to ensure that they reached their destination - the bottom of the next vertical shaft - precisely on target. The tunnel was excavated before high-performance instruments were developed for the construction of the Channel Tunnel. As no firms were willing to perform the surveying work, CERN's own surveyors, with experience from the SPS behind them, took up the challenge. At the surface, the surveyors established the world's most accurate geodetic network, performing measurements to an accuracy of 10-7, or 1mm per 10 km, using the Terrameter (see photo). The excavation of the tunnel was completed in 1988 and the finished tunnel's trajectory was found to diverge from the theoretical value specified by the p...

  5. Impedance of a slotted-pipe kicker

    Energy Technology Data Exchange (ETDEWEB)

    Feng Zhou [Academia Sinica, Beijing, BJ (China). Inst. of High Energy Physics

    1996-08-01

    This paper introduces the principle of a new slotted kicker simply, which is made by using vacuum pipe itself with proper slits as current conductors, and then, presents a rough estimation of its longitudinal and transverse impedance, respectively. Calculation shows that its impedance is reduced significantly compared to our present air-coil kicker. (author)

  6. FDTD modeling of thin impedance sheets

    Science.gov (United States)

    Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. In this paper it is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods.

  7. High temperature impedance spectroscopy of barium stannate ...

    Indian Academy of Sciences (India)

    ... differential thermal analysis, thermogravimetric analysis and Fourier transform infrared techniques. Electrical properties were studied using a.c. impedance spectroscopy technique in the temperature range of 50–650 °C and frequency range of 10 Hz–13 MHz. The complex impedance plots at temperature ≥ 300 °C show ...

  8. Determination of Transmission Line Impedance Matching Parameters

    African Journals Online (AJOL)

    In this work, transmission line impedance matching parameters were determined in Ugbowo ED0024GI Global System for Mobile Communication (GSM) base station in Benin City, Edo State, Nigeria. The transmission line impedance matching parameter viz voltage standing wave ratio was measured with the aid of the ...

  9. Possibilities of electrical impedance tomography in gynecology

    Science.gov (United States)

    V, Trokhanova O.; A, Chijova Y.; B, Okhapkin M.; V, Korjenevsky A.; S, Tuykin T.

    2013-04-01

    The paper describes results of comprehensive EIT diagnostics of mammary glands and cervix. The data were obtained from examinations of 170 patients by EIT system MEM (multi-frequency electrical impedance mammograph) and EIT system GIT (gynecological impedance tomograph). Mutual dependence is discussed.

  10. Great Lakes Science Center

    Data.gov (United States)

    Federal Laboratory Consortium — Since 1927, Great Lakes Science Center (GLSC) research has provided critical information for the sound management of Great Lakes fish populations and other important...

  11. Fractional Order Element Based Impedance Matching

    KAUST Repository

    Radwan, Ahmed Gomaa

    2014-06-24

    Disclosed are various embodiments of methods and systems related to fractional order element based impedance matching. In one embodiment, a method includes aligning a traditional Smith chart (|.alpha.|=1) with a fractional order Smith chart (|.alpha.|.noteq.1). A load impedance is located on the traditional Smith chart and projected onto the fractional order Smith chart. A fractional order matching element is determined by transitioning along a matching circle of the fractional order Smith chart based at least in part upon characteristic line impedance. In another embodiment, a system includes a fractional order impedance matching application executed in a computing device. The fractional order impedance matching application includes logic that obtains a first set of Smith chart coordinates at a first order, determines a second set of Smith chart coordinates at a second order, and determines a fractional order matching element from the second set of Smith chart coordinates.

  12. Impedance of finite length resistive cylinder

    Directory of Open Access Journals (Sweden)

    S. Krinsky

    2004-11-01

    Full Text Available We determine the impedance of a cylindrical metal tube (resistor of radius a, length g, and conductivity σ attached at each end to perfect conductors of semi-infinite length. Our main interest is in the asymptotic behavior of the impedance at high frequency (k≫1/a. In the equilibrium regime, ka^{2}≪g, the impedance per unit length is accurately described by the well-known result for an infinite length tube with conductivity σ. In the transient regime, ka^{2}≫g, where the contribution of transition radiation arising from the discontinuity in conductivity is important, we derive an analytic expression for the impedance and compute the short-range wakefield. The analytic results are shown to agree with numerical evaluation of the impedance.

  13. Power flow analysis for droop controlled LV hybrid AC-DC microgrids with virtual impedance

    DEFF Research Database (Denmark)

    Li, Chendan; Chaudhary, Sanjay; Vasquez, Juan Carlos

    2014-01-01

    The AC-DC hybrid microgrid is an effective form of utilizing different energy resources and the analysis of this system requires a proper power flow algorithm. This paper proposes a suitable power flow algorithm for LV hybrid AC-DC microgrid based on droop control and virtual impedance. Droop...... and virtual impedance concepts for AC network, DC network and interlinking converter are reviewed so as to model it in the power flow analysis. The validation of the algorithm is verified by comparing it with steady state results from detailed time domain simulation. The effectiveness of the proposed...

  14. Impedance-Based High Frequency Resonance Analysis of DFIG System in Weak Grids

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    The impedance-based model of Doubly Fed Induction Generator (DFIG) systems, including the rotor part (Rotor Side Converter (RSC) and induction machine), and the grid part (Grid Side Converter (GSC) and its output filter), has been developed for analysis and mitigation of the Sub- Synchronous...... Resonance (SSR). However, the High Frequency Resonance (HFR) of DFIG systems due to the impedance interaction between DFIG system and parallel compensated weak network is often overlooked. This paper thus investigates the impedance characteristics of DFIG systems for the analysis of HFR. The influences...... of the rotor speed variation, the machine mutual inductance and the digital control delay are evaluated. Two resonances phenomena are revealed, i.e., 1) the series HFR between the DFIG system and weak power grid; 2) the parallel HFR between the rotor part and the grid part of DFIG system. The impedance...

  15. Collimator Impedance Measurements in the LHC

    CERN Document Server

    Mounet, N; M´etral, E; Redaelli, S; Salvachua, B; Salvant, B; Valentino, G

    2013-01-01

    The collimation system of the LHC is one of the largest impedance contributors of the machine, in particular for its imaginary part. To evaluate the collimator impedance and its evolution with integrated luminosity, several measurement campaigns were performed along the year 2012, in which collimator jaws were moved back-and-forth leading to significant tune shifts for a nominal intensity bunch in the machine. These observations are compared to the results from HEADTAIL simulations with the impedance model in its current state of development.

  16. Sound Propagation An impedance Based Approach

    CERN Document Server

    Kim, Yang-Hann

    2010-01-01

    In Sound Propagation: An Impedance Based Approach , Professor Yang-Hann Kim introduces acoustics and sound fields by using the concept of impedance. Kim starts with vibrations and waves, demonstrating how vibration can be envisaged as a kind of wave, mathematically and physically. One-dimensional waves are used to convey the fundamental concepts. Readers can then understand wave propagation in terms of characteristic and driving point impedance. The essential measures for acoustic waves, such as dB scale, octave scale, acoustic pressure, energy, and intensity, are explained. These measures are

  17. SPATIAL VARIABILITY OF PEDOZEMS MECHANICAL IMPEDANCE

    Directory of Open Access Journals (Sweden)

    Zhukov A.V.

    2013-04-01

    Full Text Available We studied the spatial variability of pedozem mechanical impedance in ResearchRemediation Center of the Dnipropetrovsk State Agrarian University in Ordzhonikidze. Thestatistical distribution of the soil mechanical impedance within the studied area is characterized by deviation from the normal law in 0–10 and 30–50 cm layers from the surface. 2D and 3D modeling shows the structural design of the soil as locations of high mechanical impedance which found in the soils with less hardness.

  18. Electrical Impedance Measurements of PZT Nanofiber Sensors

    Directory of Open Access Journals (Sweden)

    Richard Galos

    2017-01-01

    Full Text Available Electrical impedance measurements of PZT nanofiber sensors were performed using a variety of methods over a frequency spectrum ranging from DC to 1.8 GHz. The nanofibers formed by electrospinning with diameters ranging from 10 to 150 nm were collected and integrated into sensors using microfabrication techniques. Special matching circuits with ultrahigh input impedance were fabricated to produce low noise, measurable sensor outputs. Material properties including resistivity and dielectric constant are derived from the impedance measurements. The resulting material properties are also compared with those of individual nanofibers being tested using conductive AFM and Scanning Conductive Microscopy.

  19. Using the critical impedance method for determining the dominant harmonic source in medium voltage circuits

    Directory of Open Access Journals (Sweden)

    Pável Julián Garcia M

    2010-04-01

    Full Text Available Automating industrial processes has led to the distortion of current and voltage waveforms, causing harmonic contamination in distribution networks. This paper shows the application of a practical methodology which de- termines the dominant harmonic source at the point of common coupling (PCC between the network operator (NO and the client. This is known as the critical impedance (CI method, requiring monitoring voltage, current and phase angle signals for each existing harmonic component and NO and client Thevenin impedance values seen in PCC. The method needs approximate impedance information to operate and a simple and structured mathematical analysis based on studying the measurements prolecting a useful, reliable and practical solution for detecting the dominant harmonic source in distribution systems.

  20. Modeling degradation in SOEC impedance spectra

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Hauch, Anne; Knibbe, Ruth

    2013-01-01

    Solid oxide cell (SOC) performance is limited by various processes. One way to investigate these processes is by electrochemical impedance spectroscopy. In order to quantify and characterize the processes, an equivalent circuit can be used to model the SOC impedance spectra (IS). Unfortunately......, the optimal equivalent circuit is often unknown and to complicate matters further, several processes contribute to the SOC impedance - making detailed process characterization difficult. In this work we analyze and model a series of IS measured during steam electrolysis operation of an SOC. During testing......, degradation is only observed in the Ni/YSZ electrode and not in the electrolyte or the LSM/YSZ electrode. A batch fit of the differences between the IS shows that a modified Gerischer element provides a better fit to the Ni/YSZ electrode impedance than the frequently used RQ element - albeit neither...

  1. Impedance and collective effects in the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Gareyte, J. [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    After a review of the main LHC parameters, and a brief description of the RF and vacuum systems, the coupling impedances of the main machine elements are given, as well as the resulting thresholds for instabilities. (author)

  2. A Rotative Electrical Impedance Tomography Reconstruction System

    Energy Technology Data Exchange (ETDEWEB)

    Yu, F-M [St. John' s and St. Mary' s Institute of Technology, Department of computer science and information Engineering, 499, Sec. 4, Tam King Road Tamsui, Taipei, Taiwan (China); Huang, C-N [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China); Chang, F-W [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China); Chung, H-Y [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China)

    2006-10-15

    Electrical impedance tomography (EIT) is a powerful tool for mapping the conductivity distribution of estimated objects. The EIT system is entirely implemented by electrical technique, so it is a relatively cheap system and data can be collected very rapidly. But it has few commercially medical EIT systems available. This is because impedance image unable to achieve the essential spatial resolution and this technique has an intrinsically poor signal to noise ratio. In this paper, we have developed a high performance rotative EIT system (REIT) for expanding the independent measurements. By rotate the electrodes successive, REIT could change the position of electrodes and acquire more measurement data. This rotative measurement method not only can increase the resolution of impedance images, but also reduce the complexity of measurement system. We hope the improvement of REIT will bring some help in electrical impedance tomography.

  3. Acoustic impedance of materials from reverberation time

    OpenAIRE

    Carocho, Antonio J.

    1991-01-01

    Approved for public release; distribution is unlimited A theoretical model is derived to calculate the specific acoustic impedance of the absorptive material covering the walls of a cavity. This model will allow the experimental determination of the specific acoustic impedance from the measurement of the reverberation time in a water-filled cavity. The model assumes a wall of low absorption. It can not be used for rigid or pressure release walls and grazzing incidence is excluded. h...

  4. CSR Impedance for Non-Ultrarelativistic Beams

    Energy Technology Data Exchange (ETDEWEB)

    Li, Rui [Jefferson Lab., Newport News, VA (United States); Tsai, Cheng Y. [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States); Jefferson Lab., Newport News, VA (United States)

    2015-09-01

    For the analysis of the coherent synchrotron radiation (CSR)-induced microbunching gain in the low energy regime, such as when a high-brightness electron beam is transported through a low-energy merger in an energy-recovery linac (ERL) design, it is necessary to extend the CSR impedance expression in the ultrarelativistic limit to the non-ultrarelativistic regime. This paper presents our analysis of CSR impedance for general beam energies.

  5. Small-signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Knott, Arnold; Iversen, Niels Elkjær

    2014-01-01

    Specifying the performance of audio ampliers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by the mechanical resonance between the mass of the diaphragm and the compliance of its' suspension which vary fr...... the loudspeaker impedance with an electric circuit and that its' resonance frequency can be changed by tuning two resistors....

  6. Analysis of impedance measurements of a suspension of microcapsules using a variable length impedance measurement cell

    Directory of Open Access Journals (Sweden)

    Dejan Krizaj

    2012-10-01

    Full Text Available Electrical impedance measurements of the suspensions have to take into account the double layer impedance that is due to a very thin charged layer formed at the electrode-electrolite interface. A dedicated measuring cell that enables variation of the distance between the electrodes was developed for investigation of electrical properties of suspensions using two electrode impedance measurements. By varying the distance between the electrodes it is possible to separate the double layer and the suspension impedance from the measured data. From measured and extracted impedances electrical lumped models have been developed. The error of non inclusion of the double layer impedance has been analyzed. The error depends on the frequency of the measurements as well as on the distance between the electrodes.

  7. Measurement of Phase Dependent Impedance for 3-phase Diode Rectifier

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2016-01-01

    to provide an optimized solution for better power quality. However, the phase dependent impedance, which is driven by both switching instant variation and frequency coupling between ac and dc network, has not been treated in the design of passive filter or harmonic compensator design for power electronics...... are still widely used in AC-DC applications because of their cost effectiveness and reliability. However, these topologies generate harmonic problems in their network due to their switching instant variation caused by the frequency and phase of grid voltage. Hence, a lot of solutions have been proposed...... with results from time-domain simulations and results from an analytical model developed in the Harmonic State-Space (HSS)....

  8. The Great Lakes

    Science.gov (United States)

    The Great Lakes form the largest surface freshwater system on Earth. The U.S. and Canada work together to restore and protect the environment in the Great Lakes Basin. Top issues include contaminated sediments, water quality and invasive species.

  9. An Electrochemical Impedance Spectroscopy System for Monitoring Pineapple Waste Saccharification

    Directory of Open Access Journals (Sweden)

    Claudia Conesa

    2016-02-01

    Full Text Available Electrochemical impedance spectroscopy (EIS has been used for monitoring the enzymatic pineapple waste hydrolysis process. The system employed consists of a device called Advanced Voltammetry, Impedance Spectroscopy & Potentiometry Analyzer (AVISPA equipped with a specific software application and a stainless steel double needle electrode. EIS measurements were conducted at different saccharification time intervals: 0, 0.75, 1.5, 6, 12 and 24 h. Partial least squares (PLS were used to model the relationship between the EIS measurements and the sugar determination by HPAEC-PAD. On the other hand, artificial neural networks: (multilayer feed forward architecture with quick propagation training algorithm and logistic-type transfer functions gave the best results as predictive models for glucose, fructose, sucrose and total sugars. Coefficients of determination (R2 and root mean square errors of prediction (RMSEP were determined as R2 > 0.944 and RMSEP < 1.782 for PLS and R2 > 0.973 and RMSEP < 0.486 for artificial neural networks (ANNs, respectively. Therefore, a combination of both an EIS-based technique and ANN models is suggested as a promising alternative to the traditional laboratory techniques for monitoring the pineapple waste saccharification step.

  10. Impedance Based Analysis and Design of Harmonic Resonant Controller for a Wide Range of Grid Impedance

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Blaabjerg, Frede

    2014-01-01

    This paper investigates the effect of grid impedance variation on harmonic resonant current controllers for gridconnected voltage source converters by means of impedance-based analysis. It reveals that the negative harmonic resistances tend to be derived from harmonic resonant controllers...... in the closed-loop output admittance of converter. Such negative resistances may interact with the grid impedance resulting in steady state error or unstable harmonic compensation. To deal with this problem, a design guideline for harmonic resonant controllers under a wide range of grid impedance is proposed...

  11. Bioelectrical impedance techniques in medicine. Part I: Bioimpedance measurement. Second section: impedance spectrometry.

    Science.gov (United States)

    Rigaud, B; Morucci, J P; Chauveau, N

    1996-01-01

    Electrical impedance spectrometry is an important application field of bioimpedance measurements. After introducing the electrical properties of biological tissues, this part presents instrumental aspects and applications of electrical impedance spectrometry. The main instrumental constraints encountered in spectrometric electrical impedance measurements are reviewed, focusing on low-frequency applications. Examples of impedance cells and probes are presented and several instrumental setups operating in the frequency and time domain are described. Some examples of applications are presented, including in vitro characterization and modeling of normal tissues, in vitro and in vivo characterization of cancerous tissues, and assessment of tissue perfusion/ischemia levels.

  12. Hybrid silicon mode-locked laser with improved RF power by impedance matching

    Science.gov (United States)

    Tossoun, Bassem; Derickson, Dennis; Srinivasan, Sudharsanan; Bowers, John

    2015-02-01

    We design and discuss an impedance matching solution for a hybrid silicon mode-locked laser diode (MLLD) to improve peak optical power coming from the device. In order to develop an impedance matching solution, a thorough measurement and analysis of the MLLD as a function of bias on each of the laser segments was carried out. A passive component impedance matching network was designed at the operating frequency of 20 GHz to optimize RF power delivery to the laser. The hybrid silicon laser was packaged together in a module including the impedance matching circuit. The impedance matching design resulted in a 6 dB (electrical) improvement in the detected modulation spectrum power, as well as approximately a 10 dB phase noise improvement, from the MLLD. Also, looking ahead to possible future work, we discuss a Step Recovery Diode (SRD) driven impulse generator, which wave-shapes the RF drive to achieve efficient injection. This novel technique addresses the time varying impedance of the absorber as the optical pulse passes through it, to provide optimum optical pulse shaping.

  13. A Study on the Optimal Receiver Impedance for SNR Maximization in Broadband PLC

    Directory of Open Access Journals (Sweden)

    Massimo Antoniali

    2013-01-01

    Full Text Available We consider the design of the front-end receiver for broadband power line communications. We focus on the design of the input impedance that maximizes the signal-to-noise ratio (SNR at the receiver. We show that the amplitude, rather than the power, of the received signal is important for communication purposes. Furthermore, we show that the receiver impedance impacts the amplitude of the noise term. We focus on the background noise, and we propose a novel description of the noise experienced at the receiver port of a PLC network. We model the noise as the sum of four uncorrelated contributions, that is, the active, resistive, receiver, and coupled noise components. We study the optimal impedance design problem for real in-home grids that we assessed with experimental measurements. We describe the results of the measurement campaign, and we report the statistics of the optimal impedance. Hence, we study the best attainable performance when the optimal receiver impedance is deployed. We focus on the SNR and the maximum achievable rate, and we show that power matching is suboptimal with respect to the proposed impedance design approach.

  14. VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS

    Directory of Open Access Journals (Sweden)

    V. I. Bankov

    2016-01-01

    Full Text Available Objective. Investigation the opportunity for measurement of biological tissue impedance to visualize its parameters.Materials and methods. Studies were undertook on the experimental facility, consists of registrating measuring cell, constructed from flat inductors system, formed in oscillatory circuit, herewith investigated biological tissue is the part of this oscillatory circuit. An excitation of oscillatory circuit fulfilled by means of exciter inductor which forms impulse complex modulated electromagnetic field (ICM EMF. The measurement process and visualizations provided by set of certificated instruments: a digital oscillograph AKTAKOM ADS-2221MV, a digital generator АКТАКОМ AWG-4150 (both with software and a gauge RLC E7-22. Comparative dynamic studies of fixed volume and weight pig’s blood, adipose tissue, muscular tissue impedance were conducted by contact versus contactless methods. Contactless method in contrast to contact method gives opportunity to obtain the real morphological visualization of biological tissue irrespective of their nature.Results. Comparison of contact and contactless methods of impedance measurement shows that the inductance to capacitance ratio X(L / X(C was equal: 17 – for muscular tissue, 4 – for blood, 1 – for adipose tissue. It demonstrates the technical correspondence of both impedance registration methods. If propose the base relevance of X (L and X (C parameters for biological tissue impedance so contactless measurement method for sure shows insulating properties of adipose tissue and high conductivity for blood and muscular tissue in fixed volume-weight parameters. Registration of biological tissue impedance complex parameters by contactless method with the help of induced ICM EMF in fixed volume of biological tissue uncovers the most important informative volumes to characterize morphofunctional condition of biological tissue namely X (L / X (C.Conclusion. Contactless method of biological

  15. Research on Large-Scale Road Network Partition and Route Search Method Combined with Traveler Preferences

    Directory of Open Access Journals (Sweden)

    De-Xin Yu

    2013-01-01

    Full Text Available Combined with improved Pallottino parallel algorithm, this paper proposes a large-scale route search method, which considers travelers’ route choice preferences. And urban road network is decomposed into multilayers effectively. Utilizing generalized travel time as road impedance function, the method builds a new multilayer and multitasking road network data storage structure with object-oriented class definition. Then, the proposed path search algorithm is verified by using the real road network of Guangzhou city as an example. By the sensitive experiments, we make a comparative analysis of the proposed path search method with the current advanced optimal path algorithms. The results demonstrate that the proposed method can increase the road network search efficiency by more than 16% under different search proportion requests, node numbers, and computing process numbers, respectively. Therefore, this method is a great breakthrough in the guidance field of urban road network.

  16. Electrical impedance tomography: so close to touching the holy grail

    OpenAIRE

    Constantin, Jean-Michel; Perbet, Sebastien; Delmas, Julie; Futier, Emmanuel

    2014-01-01

    Electrical impedance tomography is a new technology giving us lung imaging that may allow lung function to be monitored at the bedside. Several applications have been studied to guide mechanical ventilation at the bedside with electrical impedance tomography. Positive end-expiratory pressure trials guided by electrical impedance tomography are relevant in terms of recruited volume or homogeneity of the lung. Tidal impedance variation is a new parameter of electrical impedance tomography that ...

  17. Current source design for electrical impedance tomography.

    Science.gov (United States)

    Ross, Alexander S; Saulnier, G J; Newell, J C; Isaacson, D

    2003-05-01

    Questions regarding the feasibility of using electrical impedance tomography (EIT) to detect breast cancer may be answered by building a sufficiently precise multiple frequency EIT instrument. Current sources are desirable for this application, yet no current source designs have been reported that have the required precision at the multiple frequencies needed. We have designed an EIT current source using an enhanced Howland topology in parallel with a generalized impedance converter (GIC). This combination allows for nearly independent adjustment of output resistance and output capacitance, resulting in simulated output impedances in excess of 2 Gohms between 100 Hz and 1 MHz. In this paper, the theoretical operation of this current source is explained, and experimental results demonstrate the feasibility of creating a high precision, multiple frequency, capacitance compensated current source for EIT applications.

  18. Impedance plethysmographic observations in thoracic outlet syndrome.

    Directory of Open Access Journals (Sweden)

    Nerurkar S

    1990-07-01

    Full Text Available Forty patients with symptoms of neuro-vascular compression in the upper extremities were subjected to impedance plethysmographic study using Parulkar′s method. Two patients recorded decreased blood flow (BFI in supine position and were diagnosed as having partial occlusion at subclavian level. Sixteen of the patients recorded decreased BFI on 90 degrees abduction and hyper-abduction. Twelve of these patients had radiological evidence of anomalous cervicle ribs. In remaining four patients extrinsic impression on the subclavian artery due to fibrous deposits was confirmed by arteriography. Remaining 22 patients recorded normal impedance plethysmograms. Impedance plethysmography thus provided a non-invasive modality for confirmation of vascular compression in thoracic outlet syndrome.

  19. Center Impedance Method for Damping Measurement

    Directory of Open Access Journals (Sweden)

    D. Malogi

    2009-01-01

    Full Text Available Damping materials are used extensively for reduction of vibration and noise. These damping materials have viscoelastic characteristics and are used by automotive and other industries. Testing of these materials is important in order to predict their performance and traditionally the damping properties are measured by the Oberst method. This paper discusses an alternate method called the Center Impedance method where force and response are measured directly and the damping properties are obtained. The Center Impedance method is easy to use requiring only standard vibration equipment for excitation, namely, shaker, and is easy to control the experiment for repeatability. Results of beams tested by both Oberst and Center Impedance methods are presented in order to validate this test method.

  20. Ultrathin and broadband high impedance surface absorbers based on metamaterial substrates.

    Science.gov (United States)

    Pang, Yongqiang; Cheng, Haifeng; Zhou, Yongjiang; Li, Zenggnag; Wang, Jun

    2012-05-21

    An ultrathin and simultaneously broadband high impedance surface absorber based on a metamaterial (MM) substrate is presented at microwave frequencies. The MM substrate is designed using metallic split ring resonators (SRRs) vertically embedded into a dielectric slab. Both the simulated and experimental results display two absorption peaks and an expanded absorption bandwidth of less than -10 dB compared to conventional ultrathin absorbers. By analyzing the field distributions and the substrate impedance characteristics, it is found that this feature is mainly related to the LC resonance of the substrate caused by the embedded SRRs. Our results demonstrate the great feasibility of broadening the absorption bandwidth of the ultrathin high impedance surface absorbers by the MMs incorporation.

  1. Positive phase error from parallel conductance in tetrapolar bio-impedance measurements and its compensation

    Directory of Open Access Journals (Sweden)

    Ivan M Roitt

    2010-01-01

    Full Text Available Bioimpedance measurements are of great use and can provide considerable insight into biological processes.  However, there are a number of possible sources of measurement error that must be considered.  The most dominant source of error is found in bipolar measurements where electrode polarisation effects are superimposed on the true impedance of the sample.  Even with the tetrapolar approach that is commonly used to circumvent this issue, other errors can persist. Here we characterise the positive phase and rise in impedance magnitude with frequency that can result from the presence of any parallel conductive pathways in the measurement set-up.  It is shown that fitting experimental data to an equivalent electrical circuit model allows for accurate determination of the true sample impedance as validated through finite element modelling (FEM of the measurement chamber.  Finally, the model is used to extract dispersion information from cell cultures to characterise their growth.

  2. Great Lakes Literacy Principles

    Science.gov (United States)

    Fortner, Rosanne W.; Manzo, Lyndsey

    2011-03-01

    Lakes Superior, Huron, Michigan, Ontario, and Erie together form North America's Great Lakes, a region that contains 20% of the world's fresh surface water and is home to roughly one quarter of the U.S. population (Figure 1). Supporting a $4 billion sport fishing industry, plus $16 billion annually in boating, 1.5 million U.S. jobs, and $62 billion in annual wages directly, the Great Lakes form the backbone of a regional economy that is vital to the United States as a whole (see http://www.miseagrant.umich.edu/downloads/economy/11-708-Great-Lakes-Jobs.pdf). Yet the grandeur and importance of this freshwater resource are little understood, not only by people in the rest of the country but also by many in the region itself. To help address this lack of knowledge, the Centers for Ocean Sciences Education Excellence (COSEE) Great Lakes, supported by the U.S. National Science Foundation and the National Oceanic and Atmospheric Administration, developed literacy principles for the Great Lakes to serve as a guide for education of students and the public. These “Great Lakes Literacy Principles” represent an understanding of the Great Lakes' influences on society and society's influences on the Great Lakes.

  3. Great Basin insect outbreaks

    Science.gov (United States)

    Barbara Bentz; Diane Alston; Ted Evans

    2008-01-01

    Outbreaks of native and exotic insects are important drivers of ecosystem dynamics in the Great Basin. The following provides an overview of range, forest, ornamental, and agricultural insect outbreaks occurring in the Great Basin and the associated management issues and research needs.

  4. The Social Construction of the Great Belt Fixed Link

    DEFF Research Database (Denmark)

    Munch, Birgitte

    1994-01-01

    Working paper in Technology Management. Actor Network theory (ANT) used upon the process of negotiating legislation and constructing the Great Belt fixed link.......Working paper in Technology Management. Actor Network theory (ANT) used upon the process of negotiating legislation and constructing the Great Belt fixed link....

  5. Using electrical impedance tomography to map subsurface hydraulic conductivity

    Science.gov (United States)

    Berryman, James G.; Daily, William D.; Ramirez, Abelardo L.; Roberts, Jeffery J.

    2000-01-01

    The use of Electrical Impedance Tomography (EIT) to map subsurface hydraulic conductivity. EIT can be used to map hydraulic conductivity in the subsurface where measurements of both amplitude and phase are made. Hydraulic conductivity depends on at least two parameters: porosity and a length scale parameter. Electrical Resistance Tomography (ERT) measures and maps electrical conductivity (which can be related to porosity) in three dimensions. By introducing phase measurements along with amplitude, the desired additional measurement of a pertinent length scale can be achieved. Hydraulic conductivity controls the ability to flush unwanted fluid contaminants from the surface. Thus inexpensive maps of hydraulic conductivity would improve planning strategies for subsequent remediation efforts. Fluid permeability is also of importance for oil field exploitation and thus detailed knowledge of fluid permeability distribution in three-dimension (3-D) would be a great boon to petroleum reservoir analysts.

  6. Thorax mapping for localised lung impedance change using focused impedance measurement (FIM: A pilot study

    Directory of Open Access Journals (Sweden)

    Humayra Ferdous

    2013-12-01

    Full Text Available Focused Impedance Measurement (FIM is a technique where impedance can be measured with the optimum level of localization without much increase in complexity of measuring instrument. The electrodes are applied on the skin surface but the organs inside also contributes to the measurement, as the body is a volume conductor. In a healthy and disease free lung region, the air enters at breathe-in increases the impedance of the lung and impedance reduces during breathe-out. In contrast, for a diseased lung, where part of the lungs is filled with water or some fluid, air will not enter into this zone reducing impedance change between inspiration and expiration. With this idea, the current work had been executed to have general view of localised impedance change throughout thorax using 6-electrode FIM. This generated a matrix mapping from both the front and from the back of the thorax, which  afterwards provided that how impedance change due to ventilation varies from frontal plane to back plane of human bodies.

  7. A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium.

    Science.gov (United States)

    Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin

    2017-08-28

    that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.

  8. A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium

    Directory of Open Access Journals (Sweden)

    Tao Wen

    2017-08-01

    achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.

  9. Advances in High-Resolution Microscale Impedance Sensors

    Directory of Open Access Journals (Sweden)

    Marco Carminati

    2017-01-01

    Full Text Available Sensors based on impedance transduction have been well consolidated in the industry for decades. Today, the downscaling of the size of sensing elements to micrometric and submicrometric dimensions is enabled by the diffusion of lithographic processes and fostered by the convergence of complementary disciplines such as microelectronics, photonics, biology, electrochemistry, and material science, all focusing on energy and information manipulation at the micro- and nanoscale. Although such a miniaturization trend is pivotal in supporting the pervasiveness of sensors (in the context of mass deployment paradigms such as smart city, home and body monitoring networks, and Internet of Things, it also presents new challenges for the detection electronics, reaching the zeptoFarad domain. In this tutorial review, a selection of examples is illustrated with the purpose of distilling key indications and guidelines for the design of high-resolution impedance readout circuits and sensors. The applications span from biological cells to inertial and ultrasonic MEMS sensors, environmental monitoring, and integrated photonics.

  10. Design Impedance Mismatch Physical Unclonable Functions for IoT Security

    Directory of Open Access Journals (Sweden)

    Xiaomin Zheng

    2017-01-01

    Full Text Available We propose a new design, Physical Unclonable Function (PUF scheme, for the Internet of Things (IoT, which has been suffering from multiple-level security threats. As more and more objects interconnect on IoT networks, the identity of each thing is very important. To authenticate each object, we design an impedance mismatch PUF, which exploits random physical factors of the transmission line to generate a security unique private key. The characteristic impedance of the transmission line and signal transmission theory of the printed circuit board (PCB are also analyzed in detail. To improve the reliability, current feedback amplifier (CFA method is applied on the PUF. Finally, the proposed scheme is implemented and tested. The measure results show that impedance mismatch PUF provides better unpredictability and randomness.

  11. Numerical calculation of transverse coupling impedances: Comparison to Spallation Neutron Source extraction kicker measurements

    Directory of Open Access Journals (Sweden)

    B. Doliwa

    2007-10-01

    Full Text Available The study of beam dynamics and the localization of potential sources of instabilities are important tasks in the design of modern, high-intensity particle accelerators. In the case of synchrotrons and storage rings, coupling impedance data are needed to characterize the parasitic interaction of critical components with the beam. In this article we demonstrate the application of numerical field simulations to the computation of transverse kicker coupling impedances. Based on the 3D simulation results, a parametrized model is developed to incorporate the impedance of an arbitrary pulse-forming network attached to the kicker. Detailed comparisons of numerical results with twin-wire and direct measurements are discussed at the example of the Spallation Neutron Source extraction kicker.

  12. Numerical calculation of transverse coupling impedances: Comparison to Spallation Neutron Source extraction kicker measurements

    Science.gov (United States)

    Doliwa, B.; Arévalo, E.; Weiland, T.

    2007-10-01

    The study of beam dynamics and the localization of potential sources of instabilities are important tasks in the design of modern, high-intensity particle accelerators. In the case of synchrotrons and storage rings, coupling impedance data are needed to characterize the parasitic interaction of critical components with the beam. In this article we demonstrate the application of numerical field simulations to the computation of transverse kicker coupling impedances. Based on the 3D simulation results, a parametrized model is developed to incorporate the impedance of an arbitrary pulse-forming network attached to the kicker. Detailed comparisons of numerical results with twin-wire and direct measurements are discussed at the example of the Spallation Neutron Source extraction kicker.

  13. Comparison of impedance based fault location methods for power distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Mora-Florez, J. [Electrical Engineering School, Technological University of Pereira (UTP), La Julita, Pereira (Colombia); Melendez, J. [Electronics, Computer Engineering and Automatics Department, University of Girona (UdG), EPS, Campus Montilivi, 17071 Girona (Spain); Carrillo-Caicedo, G. [Electrical Engineering School, Industrial University of Santander (UIS), Cra 27-Cll 9, Bucaramanga (Colombia)

    2008-04-15

    Performance of 10 fault location methods for power distribution systems has been compared. The analyzed methods use only measurements of voltage and current at the substation. Fundamental component during pre-fault and fault are used in these methods to estimate the apparent impedance viewed from the measurement point. Deviation between pre-fault and fault impedance together with the system parameters are used to estimate the distance to the fault point. Fundamental aspects of each method have been considered in the analysis. Power system topology, line and load models and the necessity of additional information are relevant aspects that differentiate one method from another. The 10 selected methods have been implemented, tested and compared in a simulated network. The paper reports the results for several scenarios defined by significant values of the fault location and impedance. The estimated error has been used as a performance index in the comparison. (author)

  14. INFLUENCE OF CONSTRUCTIVE AND TECHNOLOGICAL DEFECTS ON COAXIAL RADIO-FREQUENCY CABLE IMPEDANCE

    Directory of Open Access Journals (Sweden)

    G.V. Bezprozvannych

    2013-04-01

    Full Text Available Coaxial user's radio-frequency cables belong to a category of cable television network elements parameters of which essentially specify the system capabilities as a whole. The cable working frequency spectrum spreading to 1000 MHz along with digital television and soundtrack signals transmission and high-definition television introduction causes more rigid requirements for wave impedance and, consequently, for the cable design. The established norms on user's cable impedance deviations fail to answer the state-of-the-art requirements for granting a complex of interactive services. On the basis of calculations performed, values of internal and external conductor diameters deviations as well as dielectric permeability of the insulation material are validated. For up-to-date user's radio-frequency cables, the impedance deviation from the normalized average value of 75 Ohm should not exceed ± 2 Ohm.

  15. Numerical modelling of impedance spectra of ionic conductor-insulator core-shell composites

    Science.gov (United States)

    Laugier, J.-M.; Raymond, L.; Albinet, G.; Knauth, P.

    2011-09-01

    Impedance spectra of ionic conductor-insulator core-shell composites are simulated in Cole-Cole and Bode representation using a 3D lattice of parallel resistance-capacitance elements. The composite model is based on a random ternary network, considering three impedance elements: good conductor (representing interface regions), conductor and insulator. The favourable interactions between the two phases lead to a significant non-random situation versus usual percolation models. Two percolation transitions are well observed: the first corresponds to ionic conduction enhancement by space charge layers. After the second transition, the conduction pathways are blocked by the insulator and the conductivity drops dramatically. Experimental impedance spectra of model copper- and lithium-ion conducting composites and nanocomposites are in good agreement with the simulation. The dc conductivity maximum can be described by a master equation: σmax ~ N-0.79 where N is proportional to the ionic conductor grain size.

  16. Estimating the short-circuit impedance

    DEFF Research Database (Denmark)

    Nielsen, Arne Hejde; Pedersen, Knud Ole Helgesen; Poulsen, Niels Kjølstad

    1997-01-01

    and current are derived each period, and the short-circuit impedance is estimated from variations in these components created by load changes in the grid. Due to the noisy and dynamic grid with high harmonic distortion it is necessary to threat the calculated values statistical. This is done recursively...

  17. Battery impedance spectroscopy using bidirectional grid connected ...

    Indian Academy of Sciences (India)

    Shimul Kumar Dam

    Impedance spectroscopy; grid connection; battery converter; state of charge; health monitoring. 1. Introduction. Batteries play an important role as energy storage devices for renewable energy sources, electric vehicle and many other applications. A battery bank is interfaced to load through a power converter, which controls ...

  18. Impedance Control of a Redundant Parallel Manipulator

    DEFF Research Database (Denmark)

    Méndez, Juan de Dios Flores; Schiøler, Henrik; Madsen, Ole

    2017-01-01

    This paper presents the design of Impedance Control to a redundantly actuated Parallel Kinematic Manipulator. The proposed control is based on treating each limb as a single system and their connection through the internal interaction forces. The controller introduces a stiffness and damping matr...

  19. Measuring mechanical impedance in clayey gravelly soils

    Directory of Open Access Journals (Sweden)

    R. Stolf

    1998-06-01

    Full Text Available Mechanical impedance of clayey and gravelly soils is often needed to interpret experimental results from tillage and other field experiments. Its measurement is difficult with manual and hydraulic penetrometers, which often bend or break in such soils. The purpose of this study was to evaluate the feasibility of a hand-operated "Stolf" impact penetrometer to measure mechanical impedance (soil resistance. The research was conducted in Raleigh, North Carolina, USA (35º 45'N, 78º 42'W, elevation 75 m. Corn was planted on April 19, 1991. Penetrometer measurements were taken on May 10, 1991, in 5 cm intervals to 60 cm at 33 locations on a transect perpendicular to the corn rows in each of four tillage treatments. The data permitted three-dimensional displays showing how mechanical impedance changed with depth and distance along the transect. The impact penetrometer proved to be a useful tool to collect quantitative mechanical impedance data on "hard" clayey and/or gravelly soils which previously were difficult to reliably quantify.

  20. Impedance and collective effects in the KEKB

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Yongho [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Oide, Katsunobu

    1996-08-01

    This paper focuses on beam instabilities due to single-beam collective effects, impedances from various beamline elements, ion trapping, photo-electrons, and other issues in the KEKB. We will also discuss the power deposition generated by a beam in the form of the Higher-Order-Mode (HOM) losses by interacting with its surroundings. (author)

  1. Variable impedance control for aerial interaction

    NARCIS (Netherlands)

    Mersha, A.Y.; Stramigioli, Stefano; Carloni, Raffaella

    This paper presents a versatile control architecture for aerial robots in interactive tasks. The control architecture is characterized by its unique capability of varying the apparent impedance of the controlled aerial robot as well as the interaction force, when in contact. This work finds its way

  2. Electrochemical impedance studies of capacity fading of ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 40; Issue 3. Electrochemical impedance studies of capacity ... P VISHNU KAMATH1. Department of Chemistry, Central College, Bangalore University, Bangalore 560 001, India; Inorganic and Physical Chemistry, Indian Institute of Science, Bangalore 560 012, India ...

  3. Impedance Calculations of Induction Machine Rotor Conductors ...

    African Journals Online (AJOL)

    The exact calculation of the impedance of induction machine rotor conductors at several operating frequencies are necessary if the dynamic behaviour of the machine is to give a good correlation between the simulated starting torque and current and the experimental results. This paper describes a method of' calculating ...

  4. Impedance Control of a Redundant Parallel Manipulator

    DEFF Research Database (Denmark)

    Méndez, Juan de Dios Flores; Schiøler, Henrik; Madsen, Ole

    2017-01-01

    This paper presents the design of Impedance Control to a redundantly actuated Parallel Kinematic Manipulator. The proposed control is based on treating each limb as a single system and their connection through the internal interaction forces. The controller introduces a stiffness and damping...

  5. Electrical impedance spectroscopy and diagnosis of tendinitis.

    Science.gov (United States)

    Yoon, Kisung; Lee, Kyeong Woo; Kim, Sang Beom; Han, Tai Ryoon; Jung, Dong Keun; Roh, Mee Sook; Lee, Jong Hwa

    2010-02-01

    There have been a number of studies that investigate the usefulness of bioelectric signals in diagnoses and treatment in the medical field. Tendinitis is a musculoskeletal disorder with a very high rate of occurrence. This study attempts to examine whether electrical impedance spectroscopy (EIS) can detect pathological changes in a tendon and find the exact location of the lesion. Experimental tendinitis was induced by injecting collagenase into one side of the patellar tendons in rabbits, while the other side was used as the control. After measuring the impedance in the tendinitis and intact tendon tissue, the dissipation factor was computed. The real component of impedance and the dissipation factor turned out to be lower in tendinitis than in intact tissues. Moreover, the tendinitis dissipation factor spectrum showed a clear difference from that of the intact tendon, indicating its usefulness as a tool for detecting the location of the lesion. Pathologic findings from the tissues that were obtained after measuring the impedance confirmed the presence of characteristics of tendinitis. In conclusion, EIS is a useful method for diagnosing tendinitis and detecting the lesion location in invasive treatment.

  6. Electrochemical Impedance Studies of SOFC Cathodes

    DEFF Research Database (Denmark)

    Hjelm, Johan; Søgaard, Martin; Wandel, Marie

    2007-01-01

    . The full cells had a Ni-YSZ anode and anode support, a thin YSZ electrolyte, and a CGO barrier layer. The symmetric and full cell cathode responses were compared at open-circuit voltage. Humidified hydrogen was used as the fuel in the full cell measurements. Differential analysis of the impedance data...

  7. Magnetotelluric impedance tensor analysis for identification of ...

    Indian Academy of Sciences (India)

    We present the results of magnetotelluric (MT) impedance tensors analyses of 18 sites located along a profile cutting various faults in the uplifted Wagad block of the Kachchh basin. The MT time series of 4–5 days recording duration have been processed and the earth response functions are estimated in broad frequency ...

  8. The electrochemical impedance of metal hydride electrodes

    DEFF Research Database (Denmark)

    Valøen, Lars Ole; Lasia, Andrzej; Jensen, Jens Oluf

    2002-01-01

    The electrochemical impedance responses for different laboratory type metal hydride electrodes were successfully modeled and fitted to experimental data for AB5 type hydrogen storage alloys as well as one MgNi type electrode. The models fitted the experimental data remarkably well. Several AC equ...

  9. Electrical Impedance Tomography Technology (EITT) Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Development of a portable, lightweight device providing two-dimensional tomographic imaging of the human body using impedance mapping. This technology can be developed to evaluate health risks and provide appropriate medical care on the ISS, during space travel and on the ground.

  10. Loudspeaker impedance emulator for multi resonant systems

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2015-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by its electrical, mechanical and acoustical properties. Therefore a loudspeaker emulator capable of adjusting...

  11. Modelling the distance impedance of protest attendance

    NARCIS (Netherlands)

    Traag, V.A.; Quax, R.; Sloot, P.M.A.

    2017-01-01

    Protesters are usually young, relatively well educated, middle class people that are politically engaged. But where do protesters come from? We here show, based on mobile phone data, that distance is an important impedance to protest attendance. Most protesters come from nearby regions, suggesting

  12. Characterisation and imaging of cortical impedance changes during interictal and ictal activity in the anaesthetised rat.

    Science.gov (United States)

    Vongerichten, Anna N; Santos, Gustavo Sato Dos; Aristovich, Kirill; Avery, James; McEvoy, Andrew; Walker, Matthew; Holder, David S

    2016-01-01

    Epilepsy affects approximately 50 million people worldwide, and 20-30% of these cases are refractory to antiepileptic drugs. Many patients with intractable epilepsy can benefit from surgical resection of the tissue generating the seizures; however, difficulty in precisely localising seizure foci has limited the number of patients undergoing surgery as well as potentially lowered its effectiveness. Here we demonstrate a novel imaging method for monitoring rapid changes in cerebral tissue impedance occurring during interictal and ictal activity, and show that it can reveal the propagation of pathological activity in the cortex. Cortical impedance was recorded simultaneously to ECoG using a 30-contact electrode mat placed on the exposed cortex of anaesthetised rats, in which interictal spikes (IISs) and seizures were induced by cortical injection of 4-aminopyridine (4-AP), picrotoxin or penicillin. We characterised the tissue impedance responses during IISs and seizures, and imaged these responses in the cortex using Electrical Impedance Tomography (EIT). We found a fast, transient drop in impedance occurring as early as 12ms prior to the IISs, followed by a steep rise in impedance within ~120ms of the IIS. EIT images of these impedance changes showed that they were co-localised and centred at a depth of 1mm in the cortex, and that they closely followed the activity propagation observed in the surface ECoG signals. The fast, pre-IIS impedance drop most likely reflects synchronised depolarisation in a localised network of neurons, and the post-IIS impedance increase reflects the subsequent shrinkage of extracellular space caused by the intense activity. EIT could also be used to picture a steady rise in tissue impedance during seizure activity, which has been previously described. Thus, our results demonstrate that EIT can detect and localise different physiological changes during interictal and ictal activity and, in conjunction with ECoG, may in future improve the

  13. A rigorous uniform diffraction analysis of the electromagnetic scattering from impedance edges and junctions

    Science.gov (United States)

    Fortney, Joseph C.

    1991-12-01

    This paper investigates the scattering from impedance strips and impedance-loaded conducting strips. The impedance strips are analyzed using Senior's impedance half plane formulation. Once the primary diffraction from the impedance half plane is presented, it is used to develop multiple diffraction mechanisms on an impedance strip. The scattering from impedance-loaded strips are analyzed using Maliuzhinets' impedance wedge formulation. The primary diffraction mechanism from an impedance wedge is used to develop the multiple diffractions on an impedance double wedge. The multiple diffractions on both types of strips are developed using the Extended Spectral Ray Method. Sample calculations are made for impedance strips and impedance-loaded strips for a large purely capacitive impedance, a large purely inductive impedance, a large real impedance, and a small real impedance. Measurements are made for impedance strips and impedance loaded strips and are used to compare against predictions. The impedance materials used are two magnetic radar absorbing materials and two resistive materials.

  14. Prediction of intramuscular fat by impedance spectroscopy.

    Science.gov (United States)

    Altmann, M; Pliquett, U

    2006-04-01

    Multiple multi-frequency impedance measurements during the computer controlled passage of a probe through the M. longissimus dorsi in pork and beef were applied. It was expected that the variability in impedance would correlate with the intramuscular fat (IMF) due to the inhomogeneous distribution of electrolytes and fat. We conducted our experiments in pig carcasses at different, well defined times post-mortem in varying directions of puncture (Experiment 1) and predicted the intramuscular fat in pork and beef by regression (Experiment 2). The highest correlations were obtained in experiment 1 for parameters characterising the variability of the impedance 24h post-mortem and insertion of the probe through the back fat and muscle towards the body cavity (r=0.54-0.79, Pexperiment 2. Regression for the prediction of IMF in pork and beef in experiment 2 resulted in R(2) values of 0.12 and 0.48, respectively; and in RMSE values of 0.67 and 0.64, respectively. The correlation between the predicted and the IMF analysed by n-hexane extraction or Near Infrared Transmission varied from 0.28 to 0.69 (PIMF (above a certain threshold) using the impedance measurements agreed poorly with the analysed IMF. Depending on the level of IMF within a breed, low IMF contents were often over-predicted (3.4-92.7%) or high IMF contents were estimated as too low (0-80.9%). Breed specific regression equations could improve the accuracy. These data indicate that the selectivity of the impedance method in the configuration presented here is not yet sufficient for practical use.

  15. Crack detection in pipelines using multiple electromechanical impedance sensors

    Science.gov (United States)

    Zuo, Chunyuan; Feng, Xin; Zhang, Yu; Lu, Lu; Zhou, Jing

    2017-10-01

    An extensive network of pipeline systems is used to transport and distribute national energy resources that heavily influence a nation’s economy. Therefore, the structural integrity of these pipeline systems must be monitored and maintained. However, structural damage detection remains a challenge in pipeline engineering. To this end, this study developed a modified electromechanical impedance (EMI) technique for crack detection that involves fusing information from multiple sensors. We derived a new damage-sensitive feature factor based on a pipeline EMI model that considers the influence of the bonding layer between the EMI sensors and pipeline. We experimentally validated the effectiveness of the proposed method. Finally, we used a damage index—root mean square deviation—to examine the degree and position of crack damage in a pipeline.

  16. Modeling Stochastic Route Choice Behaviors with Equivalent Impedance

    Directory of Open Access Journals (Sweden)

    Jun Li

    2015-01-01

    Full Text Available A Logit-based route choice model is proposed to address the overlapping and scaling problems in the traditional multinomial Logit model. The nonoverlapping links are defined as a subnetwork, and its equivalent impedance is explicitly calculated in order to simply network analyzing. The overlapping links are repeatedly merged into subnetworks with Logit-based equivalent travel costs. The choice set at each intersection comprises only the virtual equivalent route without overlapping. In order to capture heterogeneity in perception errors of different sizes of networks, different scale parameters are assigned to subnetworks and they are linked to the topological relationships to avoid estimation burden. The proposed model provides an alternative method to model the stochastic route choice behaviors without the overlapping and scaling problems, and it still maintains the simple and closed-form expression from the MNL model. A link-based loading algorithm based on Dial’s algorithm is proposed to obviate route enumeration and it is suitable to be applied on large-scale networks. Finally a comparison between the proposed model and other route choice models is given by numerical examples.

  17. The GREAT spectrometer

    CERN Document Server

    Page, R D; Appelbe, D E; Butler, P A; Freeman, S J; Greenlees, P T; Herzberg, R D; Jenkins, D G; Jones, G D; Jones, P; Joss, D T; Julin, R; Kettunen, H; Leino, M; Rahkila, P; Regan, P H; Simpson, J; Uusitalo, J; Vincent, S M; Wadsworth, R

    2003-01-01

    The GREAT spectrometer is designed to measure the decay properties of reaction products transported to the focal plane of a recoil separator. GREAT comprises a system of silicon, germanium and gas detectors optimised for detecting the arrival of the reaction products and correlating with any subsequent radioactive decay involving the emission of protons, alpha particles, beta particles, gamma rays, X-rays or conversion electrons. GREAT can either be employed as a sensitive stand-alone device for decay measurements at the focal plane, or used to provide a selective tag for prompt conversion electrons or gamma rays measured with arrays of detectors deployed at the target position. A new concept of triggerless data acquisition (total data readout) has also been developed as part of the GREAT project, which circumvents the problems and limitations of common dead time in conventional data acquisition systems.

  18. Great Indoors Awards 2007

    Index Scriptorium Estoniae

    2007-01-01

    Hollandis Maastrichtis jagati 17. XI esimest korda rahvusvahelist auhinda The Great Indoors Award. Aasta sisekujundusfirmaks valiti Masamichi Katayama asutatud Wonderwall. Auhinna said veel Zaha Hadid, Heatherwick Studio, Ryui Nakamura Architects ja Item Idem

  19. The Great adventure

    National Research Council Canada - National Science Library

    Lemire, J; Plantanida, T; Suzuki, D

    2003-01-01

    .... We watch as the crew navigate a three-masted sailing ship through the legendary Northwest Passage - a treacherous, ice-choked route that has captured the imaginations of great explores for centuries...

  20. Great Lakes Bathymetry

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Bathymetry of Lakes Michigan, Erie, Saint Clair, Ontario and Huron has been compiled as a component of a NOAA project to rescue Great Lakes lake floor geological and...

  1. Sensor networks

    NARCIS (Netherlands)

    Chatterjea, Supriyo; Thurston, J.; Kininmonth, S.; Havinga, Paul J.M.

    2006-01-01

    This article describes the details of a sensor network that is currently being deployed at the Great Barrier Reef in Australia. The sensor network allows scientists to retrieve sensor data that has a high spatial and temporal resolution. We give an overview of the energy-efficient data aggregation

  2. Performance of an implantable impedance spectroscopy monitor using ZigBee

    Science.gov (United States)

    Bogónez-Franco, P.; Bayés-Genís, A.; Rosell, J.; Bragós, R.

    2010-04-01

    This paper presents the characterization measurements of an implantable bioimpedance monitor with ZigBee. Such measurements are done over RC networks, performing short and long-term measurements, with and without mismatch in electrodes and varying the temperature and the RF range. The bioimpedance monitor will be used in organ monitoring through electrical impedance spectroscopy in the 100 Hz - 200 kHz range. The specific application is the study of the viability and evolution of engineered tissue in cardiac regeneration in an experimental protocol with pig models. The bioimpedance monitor includes a ZigBee transceiver to transmit the measured data outside the animal chest. The bioimpedance monitor is based in the 12 Bit Impedance Converter and Network Analyzer AD5933, improved with an analog front-end that implements a 4-electrode measurement structure and allows to measure small impedances. In the debugging prototype, the system autonomy exceeds 1 month when a 14 frequencies impedance spectrum is acquired every 5 minutes. The receiver side consists of a ZigBee transceiver connected to a PC to process the received data. In the current implementation, the effective range of the RF link was of a few centimeters, then needing a range extender placed close to the animal. We have increased it by using an antenna with higher gain. Basic errors in the phantom circuit parameters estimation after model fitting are below 1%.

  3. A Kalman filter approach to track fast impedance changes in electrical impedance tomography.

    Science.gov (United States)

    Vauhkonen, M; Karjalainen, P A; Kaipio, J P

    1998-04-01

    In electrical impedance tomography (EIT), an estimate for the cross-sectional impedance distribution is obtained from the body by using current and voltage measurements made from the boundary. All well-known reconstruction algorithms use a full set of independent current patterns for each reconstruction. In some applications, the impedance changes may be so fast that information on the time evolution of the impedance distribution is either lost or severely blurred. In this paper, we propose an algorithm for EIT reconstruction that is able to track fast changes in the impedance distribution. The method is based on the formulation of EIT as a state-estimation problem and the recursive estimation of the state with the aid of the Kalman filter. The performance of the proposed method is evaluated with a simulation of human thorax in a situation in which the impedances of the ventricles change rapidly. We show that with optimal current patterns and proper parameterization, the proposed approach yields significant enhancement of the temporal resolution over the conventional reconstruction strategy.

  4. Improving the Stability and Accuracy of Power Hardware-in-the-Loop Simulation Using Virtual Impedance Method

    Directory of Open Access Journals (Sweden)

    Xiaoming Zha

    2016-11-01

    Full Text Available Power hardware-in-the-loop (PHIL systems are advanced, real-time platforms for combined software and hardware testing. Two paramount issues in PHIL simulations are the closed-loop stability and simulation accuracy. This paper presents a virtual impedance (VI method for PHIL simulations that improves the simulation’s stability and accuracy. Through the establishment of an impedance model for a PHIL simulation circuit, which is composed of a voltage-source converter and a simple network, the stability and accuracy of the PHIL system are analyzed. Then, the proposed VI method is implemented in a digital real-time simulator and used to correct the combined impedance in the impedance model, achieving higher stability and accuracy of the results. The validity of the VI method is verified through the PHIL simulation of two typical PHIL examples.

  5. Enhanced Method for Cavity Impedance Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Frank Marhauser, Robert Rimmer, Kai Tian, Haipeng Wang

    2009-05-01

    With the proposal of medium to high average current accelerator facilities the demand for cavities with extremely low Higher Order Mode (HOM) impedances is increasing. Modern numerical tools are still under development to more thoroughly predict impedances that need to take into account complex absorbing boundaries and lossy materials. With the usually large problem size it is preferable to utilize massive parallel computing when applicable and available. Apart from such computational issues, we have developed methods using available computer resources to enhance the information that can be extracted from a cavities? wakefield computed in time domain. In particular this is helpful for a careful assessment of the extracted RF power and the mitigation of potential beam break-up or emittance diluting effects, a figure of merit for the cavity performance. The method is described as well as an example of its implementation.

  6. Electrical conductivity and impedance behaviour of hydrogels

    Science.gov (United States)

    Warren, Holly; in het Panhuis, Marc

    2014-08-01

    The impedance and electrical conductivity behavior of gellan gum hydrogels containing the conducting fillers poly(3,4- ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) and vapour grown carbon nanofibers (VGCNF) is presented. Impedance analysis showed that an equivalent circuit consisting of a Warburg element in series with a resistor could be used to model the gels' behavior. It is demonstrated that the addition of the conducting fillers PEDOT:PSS and VGCNFs can result in a measurable improvement in the conductivity of hydrogels with high water content and swelling ratios. Incorporation of combinations of these conducting fillers resulted in an improvement of the conductivity of gellan gum-containing hydrogels with water content (swelling ratio) of at least 97.5% (40) from 1.2 +/- 0.1 mS/cm to 4 +/- 0.6 mS/cm.

  7. Beam measurements of the SPS longitudinal impedance

    CERN Document Server

    Lasheen, A

    2017-01-01

    Longitudinal instabilities are one of the main limitationsin the CERN SPS to reach the beam parameters requiredfor the High Luminosity LHC project. In preparation tothe SPS upgrade, possible remedies are studied by perform-ing macroparticle simulations using the machine impedancemodel obtained from electromagnetic simulations and mea-surements. To benchmark the impedance model, the resultsof simulations are compared with various beam measure-ments. In this study, the reactive part of the impedance wasprobed by measuring the quadrupole frequency shift withintensity, obtained from bunch length oscillations at mis-matched injection into the SPS. This method was appliedover many last years to follow up the evolution of the SPSimpedance, injecting bunches with the same bunch length.A novel approach, giving significantly more information,consists in varying the injected bunch length. The compari-son of these measurements with macroparticle simulationsallowed to test the existing model and identify some missingSPS i...

  8. Simulated impedance of diffusion in porous media

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Samuel J.; Bertei, Antonio; Finegan, Donal P.; Brandon, Nigel P.

    2017-10-01

    This paper describes the use of a frequency domain, finite-difference scheme to simulate the impedance spectra of diffusion in porous microstructures. Both open and closed systems are investigated for a range of ideal geometries, as well as some randomly generated synthetic volumes and tomographically derived microstructural data. In many cases, the spectra deviate significantly from the conventional Warburg-type elements typically used to represent diffusion in equivalent circuit analysis. A key finding is that certain microstructures show multiple peaks in the complex plane, which may be misinterpreted as separate electrochemical processes in real impedance data. This is relevant to battery electrode design as the techniques for nano-scale fabrication become more widespread. This simulation tool is provided as an open-source MatLab application and is freely available online as part of the TauFactor platform.

  9. FEM electrode refinement for electrical impedance tomography.

    Science.gov (United States)

    Grychtol, Bartlomiej; Adler, Andy

    2013-01-01

    Electrical Impedance Tomography (EIT) reconstructs images of electrical tissue properties within a body from electrical transfer impedance measurements at surface electrodes. Reconstruction of EIT images requires the solution of an inverse problem in soft field tomography, where a sensitivity matrix, J, of the relationship between internal changes and measurements is calculated, and then a pseudo-inverse of J is used to update the image estimate. It is therefore clear that a precise calculation of J is required for solution accuracy. Since it is generally not possible to use analytic solutions, the finite element method (FEM) is typically used. It has generally been recommended in the EIT literature that FEMs be refined near electrodes, since the electric field and sensitivity is largest there. In this paper we analyze the accuracy requirement for FEM refinement near electrodes in EIT and describe a technique to refine arbitrary FEMs.

  10. Iterative Reconstruction Methods for Hybrid Inverse Problems in Impedance Tomography

    DEFF Research Database (Denmark)

    Hoffmann, Kristoffer; Knudsen, Kim

    2014-01-01

    impedance imaging, magnetic resonance electrical impedance tomography, and ultrasound modulated electrical impedance tomography, and the unified approach to the reconstruction problem encompasses several algorithms suggested in the literature. The four proposed algorithms are implemented numerically in two......For a general formulation of hybrid inverse problems in impedance tomography the Picard and Newton iterative schemes are adapted and four iterative reconstruction algorithms are developed. The general problem formulation includes several existing hybrid imaging modalities such as current density...

  11. Detecting stochastic inclusions in electrical impedance tomography

    Science.gov (United States)

    Barth, Andrea; Harrach, Bastian; Hyvönen, Nuutti; Mustonen, Lauri

    2017-11-01

    This work considers the inclusion detection problem of electrical impedance tomography with stochastic conductivities. It is shown that a conductivity anomaly with a random conductivity can be identified by applying the factorization method or the monotonicity method to the mean value of the corresponding Neumann-to-Dirichlet map provided that the anomaly has high enough contrast in the sense of expectation. The theoretical results are complemented by numerical examples in two spatial dimensions.

  12. Tuned driving of piezoelectric resonators: impedance matching

    OpenAIRE

    Pons, J. L.; Fernández, J .F.; Villegas, M.; Ochoa, P; Ceres, R.; L. Calderón; E. Rocon

    2006-01-01

    For optimal operation of piezoelectric resonators, the electrical impedance of electronic drivers and the resonator itself must be matched. Lack of matching results in a non smooth transmission of electrical power between the drive and the load which, in turn, leads to heating and poor efficiency. The rest of properties of the driving voltage (frequency, amplitude and phase) are also affected by this mismatch. This paper presents the optimal design of power drivers for piezoelectric resonator...

  13. Tuned driving of piezoelectric resonators: impedance matching

    OpenAIRE

    Fernández Lozano, José Francisco; Villegas, Marina; Ochoa, Pilar; Pons Rovira, José Luis; Ceres Ruiz, Ramón; Calderón Estévez, Leopoldo; Rocón, Eduardo

    2006-01-01

    [EN] For optimal operation of piezoelectric resonators, the electrical impedance of electronic drivers and the resonator itself must be matched. Lack of matching results in a non smooth transmission of electrical power between the drive and the load which, in turn, leads to heating and poor efficiency. The rest of properties of the driving voltage (frequency, amplitude and phase) are also affected by this mismatch. This paper presents the optimal design of power drivers for piezoelec...

  14. IMPEDANCE SPECTROSCOPY OF POLYCRYSTALLINE TIN DIOXIDE FILMS

    Directory of Open Access Journals (Sweden)

    D. V. Adamchuck

    2016-01-01

    Full Text Available The aim of this work is the analysis of the influence of annealing in an inert atmosphere on the electrical properties and structure of non-stoichiometric tin dioxide films by means of impedance spectroscopy method. Non-stoichiometric tin dioxide films were fabricated by two-step oxidation of metallic tin deposited on the polycrystalline Al2O3 substrates by DC magnetron sputtering. In order to modify the structure and stoichiometric composition, the films were subjected to the high temperature annealing in argon atmosphere in temperature range 300–800 °С. AC-conductivity measurements of the films in the frequency range 20 Hz – 2 MHz were carried out. Variation in the frequency dependencies of the real and imaginary parts of the impedance of tin dioxide films was found to occur as a result of high-temperature annealing. Equivalent circuits for describing the properties of films with various structure and stoichiometric composition were proposed. Possibility of conductivity variation of the polycrystalline tin dioxide films as a result of аnnealing in an inert atmosphere was demonstrated by utilizing impedance spectroscopy. Annealing induces the recrystallization of the films, changing in their stoichiometry as well as increase of the sizes of SnO2 crystallites. Variation of electrical conductivity and structure of tin dioxide films as a result of annealing in inert atmosphere was confirmed by X-ray diffraction analysis. Analysis of the impedance diagrams of tin dioxide films was found to be a powerful tool to study their electrical properties. 

  15. Impedance Control of a Redundant Parallel Manipulator

    DEFF Research Database (Denmark)

    Méndez, Juan de Dios Flores; Schiøler, Henrik; Madsen, Ole

    2017-01-01

    This paper presents the design of Impedance Control to a redundantly actuated Parallel Kinematic Manipulator. The proposed control is based on treating each limb as a single system and their connection through the internal interaction forces. The controller introduces a stiffness and damping...... matrices that decouples the dynamic behaviour of the robot. Control allocation of torques is applied through an optimization that promotes even distribution of torques over actuators. Simulations showed a good compliance behaviour in low frequencies....

  16. Steps towards 3D Electrical Impedance Tomography.

    Science.gov (United States)

    Schullcke, Benjamin; Gong, Bo; Moeller, Knut

    2015-01-01

    Electrical Impedance Tomography (EIT) is a promising imaging technique to visualize the dynamics of regional lung ventilation. 2D EIT has shown promise in monitoring ventilation therapy, with the drawback of only displaying a single horizontal slice of the lungs. Until now there are no generally accepted approaches available to generate meaningful 3D images in real-time. This paper describes general problems and first attempts to overcome those that may extend to a hierarchical scheme for 3D EIT imaging.

  17. Applications of Nonlinear Electrochemical Impedance Spectroscopy (NLEIS)

    KAUST Repository

    Adler, S. B.

    2013-08-31

    This paper reviews the use of nonlinear electrochemical impedance spectroscopy (NLEIS) in the analysis of SOFC electrode reactions. By combining EIS and NLEIS, as well as other independent information about an electrode material, it becomes possible to establish quantitative links between electrochemical kinetics and materials properties, even when systems are unstable with time. After a brief review of the method, this paper summarizes recent results analyzing the effects of Sr segregation in thin-film LSC electrodes. © The Electrochemical Society.

  18. Bioelectrical impedance analysis of bovine milk fat

    Science.gov (United States)

    Veiga, E. A.; Bertemes-Filho, P.

    2012-12-01

    Three samples of 250ml at home temperature of 20°C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.

  19. Application of impedance spectroscopy to SOFC research

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, G.; Mason, T.O. [Northwestern Univ., Evanston, IL (United States); Pederson, L.R. [Pacific Northwest National Lab., Richland, WA (United States)

    1996-12-31

    With the resurgence of interest in solid oxide fuel cells and other solid state electrochemical devices, techniques originally developed for characterizing aqueous systems are being adapted and applied to solid state systems. One of these techniques, three-electrode impedance spectroscopy, is particularly powerful as it allows characterization of subcomponent and interfacial properties. Obtaining accurate impedance spectra, however, is difficult as reference electrode impedance is usually non-negligible and solid electrolytes typically have much lower conductance than aqueous solutions. Faidi et al and Chechirlian et al have both identified problems associated with low conductivity media. Other sources of error are still being uncovered. Ford et al identified resistive contacts with large time constants as a possibility, while Me et al showed that the small contact capacitance of the reference electrode was at fault. Still others show that instrument limitations play a role. Using the voltage divider concept, a simplified model that demonstrates the interplay of these various factors, predicts the form of possible distortions, and offers means to minimize errors is presented.

  20. Estimating the Transverse Impedance in the Fermilab Recycler

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, Robert [Fermilab; Adamson, Philip [Fermilab; Burov, Alexey [Fermilab; Kourbanis, Ioanis [Fermilab; Yang, Ming-Jen [Fermilab

    2016-06-01

    Impedance could represent a limitation of running high intensity bunches in the Fermilab recycler. With high intensity upgrades foreseen, it is important to quantify the impedance. To do this, studies have been performed measuring the tune shift as a function of bunch intensity allowing the transverse impedance to be derived.

  1. PHEMT Distributed Power Amplifier Adopting Broadband Impedance Transformer

    DEFF Research Database (Denmark)

    Narendra, K.; Limiti, E.; Paoloni, C.

    2013-01-01

    A non-uniform drain line distributed power amplifier (DPA) employing a broadband impedance transformer is presented. The DPA is based on GaAs PHEMT technology. The impedance transformer employs asymmetric coupled lines and transforms a low output impedance of the amplifier to a standard 50 Ω...

  2. 21 CFR 874.1090 - Auditory impedance tester.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Auditory impedance tester. 874.1090 Section 874...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Diagnostic Devices § 874.1090 Auditory impedance tester. (a) Identification. An auditory impedance tester is a device that is intended to change the air pressure in the...

  3. Use of electrical impedance tomography to monitor regional cerebral edema during clinical dehydration treatment.

    Science.gov (United States)

    Fu, Feng; Li, Bing; Dai, Meng; Hu, Shi-Jie; Li, Xia; Xu, Can-Hua; Wang, Bing; Yang, Bin; Tang, Meng-Xing; Dong, Xiu-Zhen; Fei, Zhou; Shi, Xue-Tao

    2014-01-01

    Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content. a prospective study. In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank. 23 patients with brain edema. The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes. Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027). Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients' responses to such treatment. EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients.

  4. Design of current source for multi-frequency simultaneous electrical impedance tomography

    Science.gov (United States)

    Han, Bing; Xu, Yanbin; Dong, Feng

    2017-09-01

    Multi-frequency electrical impedance tomography has been evolving from the frequency-sweep approach to the multi-frequency simultaneous measurement technique which can reduce measuring time and will be increasingly attractive for time-varying biological applications. The accuracy and stability of the current source are the key factors determining the quality of the image reconstruction. This article presents a field programmable gate array-based current source for a multi-frequency simultaneous electrical impedance tomography system. A novel current source circuit was realized by combining the classic current mirror based on the feedback amplifier AD844 with a differential topology. The optimal phase offsets of harmonic sinusoids were obtained through the crest factor analysis. The output characteristics of this current source were evaluated by simulation and actual measurement. The results include the following: (1) the output impedance was compared with one of the Howland pump circuit in simulation, showing comparable performance at low frequencies. However, the proposed current source makes lower demands for resistor tolerance but performs even better at high frequencies. (2) The output impedance in actual measurement below 200 kHz is above 1.3 MΩ and can reach 250 KΩ up to 1 MHz. (3) An experiment based on a biological RC model has been implemented. The mean error for the demodulated impedance amplitude and phase are 0.192% and 0.139°, respectively. Therefore, the proposed current source is wideband, biocompatible, and high precision, which demonstrates great potential to work as a sub-system in the multi-frequency electrical impedance tomography system.

  5. Use of electrical impedance tomography to monitor regional cerebral edema during clinical dehydration treatment.

    Directory of Open Access Journals (Sweden)

    Feng Fu

    Full Text Available OBJECTIVE: Variations of conductive fluid content in brain tissue (e.g. cerebral edema change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT, an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content. DESIGN: a prospective study. SETTING: In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank. PATIENTS: 23 patients with brain edema. INTERVENTIONS: The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes. MEASUREMENT AND MAIN RESULTS: Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027. Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients' responses to such treatment. CONCLUSIONS: EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients.

  6. Integration of a network aware traffic generation device into a computer network emulation platform

    CSIR Research Space (South Africa)

    Von Solms, S

    2014-07-01

    Full Text Available Flexible, open source network emulation tools can provide network researchers with significant benefits regarding network behaviour and performance. The evaluation of these networks can benefit greatly from the integration of realistic, network...

  7. Great Leap into Famine

    OpenAIRE

    Ó Gráda, Cormac

    2011-01-01

    Frank Dikötter’s Mao's Great Famine: The History of China's Most Devastating Catastrophe, 1958-62 is the longest and most detailed study of the Great Leap Forward (GLF) famine to appear in English to date. Much of the story will be already familiar to western readers from works by Roderick McFarquhar (1983), Jasper Becker (1996), Ralph Thaxton (2008), and others, but Dikötter adds a lot that is new and valuable. For the past decade or so Chinese scholars have been publishing works based on pu...

  8. Journeys to greatness

    Science.gov (United States)

    Crease, Robert P.

    2009-02-01

    Readers, I hope, will forgive me for a shameless bit of self-publicity about my latest book, The Great Equations: Breakthroughs in Science from Pythagoras to Heisenberg (Norton). But then the book is partly yours too, inspired as it was by the responses of Physics World readers to my request for suggestions of great equations (October 2004 pp14-15). In the book, I chose to discuss not the most frequently mentioned equations, but those that seem to have engaged their discoverers in the most remarkable journeys.

  9. Comparison of Howland and General Impedance Converter (GIC) circuit based current sources for bio-impedance measurements

    OpenAIRE

    Qureshi, Tabassum-Ur-Razaq; Chatwin, Chris; Huber, Nicolas; Zarafshani, Ali; Tunstall, Benjamin; Wang, Wei

    2010-01-01

    The current source is a key component in bio-impedance measurement systems. The accuracy of the current source can be measured in terms of its output impedance together with other parameters, with certain applications demanding extremely high output impedance. This paper presents an investigation and comparison of different current source designs based on the Enhanced Howland circuit combined with a General Impedance Converter (GIC) circuit using both ideal and non-ideal operational amplifier...

  10. Great Barrier Reef

    Science.gov (United States)

    2002-01-01

    A better than average view of the Great Barrier Reef was captured by SeaWiFS on a recent overpass. There is sunglint northeast of the reef and there appears to be some sort of filamentous bloom in the Capricorn Channel.

  11. Great Experiments in Physics

    Indian Academy of Sciences (India)

    ... Public Lectures · Lecture Workshops · Refresher Courses · Symposia. Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 11. Great Experiments in Physics - Discovery of the Cosmic Microwave Background Radiation. Amit Roy. Series Article Volume 5 Issue 11 November 2000 pp 4-13 ...

  12. Great Expectations. [Lesson Plan].

    Science.gov (United States)

    Devine, Kelley

    Based on Charles Dickens' novel "Great Expectations," this lesson plan presents activities designed to help students understand the differences between totalitarianism and democracy; and a that a writer of a story considers theme, plot, characters, setting, and point of view. The main activity of the lesson involves students working in groups to…

  13. The Great Dismal Swamp

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This introduction to the natural history of the Great Dismal Swamp is presented at a time when 50,000 acres of the Swamp are being converted from private holdings to...

  14. Great Experiments in Physics

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 5. Great Experiments in Physics - Measuring Diameters of Stars: The Hanbury Brown-Twiss Effect. Amit Roy. Series Article ... Author Affiliations. Amit Roy1. Nuclear Science Centre, Aruna Asaf Ali Marg, P.O. Box 10502 New Delhi 110 067, India.

  15. Great Experiments in Physics

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 10. Great Experiments in Physics - Birth of Quantum Electronics – Lasers. Amit Roy. Series Article Volume 4 Issue 10 ... Author Affiliations. Amit Roy1. Nuclear Science Centre, Aruna Asaf Ali Marg, P.O. Box 10502, New Delhi 110 067, India.

  16. Great Experiments in Physics

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 9. Great Experiments in Physics - Birth of Quantum Electronics – Masers. Amit Roy. Series Article Volume 4 Issue 9 ... Author Affiliations. Amit Roy1. Nuclear Science Centre, Aruna Asaf Ali Marg, P.O. Box 10502, New Delhi 110 067, India.

  17. Impedance cardiography: A valuable method of evaluating haemodynamic parameters.

    Science.gov (United States)

    Sodolski, Tomasz; Kutarski, Andrzej

    2007-01-01

    This year marks 40 years since the technique was designed of measuring and monitoring the basic haemodynamic parameters in humans by means of impedance cardiography (ICG), also known as "impedance plethysmography of the chest", "electrical bioimpedance of the chest" or "reocardiography". The method makes it possible to denote stroke volume and cardiac output. It also enables the factors to be assessed that influence the following: preload (measurement of thoracic fluid content), afterload (measurement of systemic vascular resistance), the systemic vascular resistance index, contractibility (measurement of the acceleration index), the velocity index, the pre-ejection period, left ventricular ejection time, systolic time ratio and heart rate. Advances in hardware and software, including digital signal tooling and new algorithms, have certainly improved the quality of the results obtained. The accuracy and repeatability of the results have been confirmed in comparative studies with results obtained through invasive methods and echocardiography. Not only are haemodynamic changes monitored by means of ICG in intensive care units, in operating theatres and at haemodialysis stations, but repeated measurements also provide haemodynamic information during the treatment of patients with hypertension and heart failure and pregnant women with cardiological problems and gestosis. A single ICG investigation makes a great contribution to the basic information available about the circulatory system, which is helpful in the initial evaluation of patients in a severe general condition (for example in the admission room), and also makes it possible to make a swift diagnosis of the cause of complaints such as dyspnoea and hypotonia. A particular application of ICG is the assessment of haemodynamic parameters during the programming of atrioventricular and CRT pacemakers. Besides these uses, ICG is a valuable investigative tool. It is defect-free and does not have pulmonary artery

  18. What great managers do.

    Science.gov (United States)

    Buckingham, Marcus

    2005-03-01

    Much has been written about the qualities that make a great manager, but most of the literature overlooks a fundamental question: What does a great manager actually do? While there are countless management styles, one thing underpins the behavior of all great managers. Above all, an exceptional manager comes to know and value the particular quirks and abilities of her employees. She figures out how to capitalize on her staffers' strengths and tweaks her environment to meet her larger goals. Such a specialized approach may seem like a lot of work. But in fact, capitalizing on each person's uniqueness can save time. Rather than encourage employees to conform to strict job descriptions that may include tasks they don't enjoy and aren't good at, a manager who develops positions for his staff members based on their unique abilities will be rewarded with behaviors that are far more efficient and effective than they would be otherwise. This focus on individuals also makes employees more accountable. Because staffers are evaluated on their particular strengths and weaknesses, they are challenged to take responsibility for their abilities and to hone them. Capitalizing on a person's uniqueness also builds a stronger sense of team. By taking the time to understand what makes each employee tick, a great manager shows that he sees his people for who they are. This personal investment not only motivates individuals but also galvanizes the entire team. Finally, this approach shakes up existing hierarchies, which leads to more creative thinking. To take great managing from theory to practice, the author says, you must know three things about a person: her strengths, the triggers that activate those strengths, and how she learns. By asking the right questions, squeezing the right triggers, and becoming aware of your employees' learning styles, you will discover what motivates each person to excel.

  19. Impedance pattern of vaginal and vestibular mucosa in cyclic goats

    Directory of Open Access Journals (Sweden)

    Ivo Křivánek

    2008-01-01

    Full Text Available The changes of vaginal and vestibular impedance during the oestrous cycle in goats were examined. The onset of oestrus was teased with a buck once a day during the experiment. Impedance was mea­sured by a four-terminal method. The vaginal impedance was recorded under slight pressure of electrodes to the vaginal dorsal wall at the cervix. The vestibular impedance was recorded under slight pressure of electrodes to the vestibular dorsal wall 5 cm from the vulva and at the vulva. The im­pe­dan­ce was measured once a day from 4 days before the expected oestrus to 6 days after onset of oestrus. The vaginal impedance at the cervix decreased during pro-oestrus (P < 0.01 and increased du­ring oestrus (P < 0.01. The vestibular impedance 5 cm from the vulva decreased during pro-oestrus (P < 0.01 and increased after oestrus (P < 0.01. The decrease of vaginal impedance during peri-oestrus was nearly twofold in comparison with the vestibular impedance 5 cm from the vulva. No sig­ni­fi­cant decrease of the vestibular impedance at the vulva was found during the oestrous cycle. The results indicate that the vaginal impedance at the cervix and vestibular impedance 5 cm from the vulva measured by means of a four-terminal method during the oestrous cycle display cyclic changes that are closely related to the oestrous behaviour of goats.

  20. Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review

    Science.gov (United States)

    Bera, Tushar Kanti

    2014-01-01

    Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends. PMID:27006932

  1. Impedance coordinative control for cascaded converter in bidirectional application

    DEFF Research Database (Denmark)

    Tian, Yanjun; Loh, Poh Chiang; Deng, Fujin

    2016-01-01

    A two-stage cascaded converter is formed by connecting two sub-converters in series. Output impedance of one sub-converter will therefore interact with input impedance of the other sub-converter. Such interaction may affect the system dynamics and stability, especially when one sub-converter is c......A two-stage cascaded converter is formed by connecting two sub-converters in series. Output impedance of one sub-converter will therefore interact with input impedance of the other sub-converter. Such interaction may affect the system dynamics and stability, especially when one sub......-converter is constant-power-controlled, and hence has different impedance characteristics when its power reverses. To lessen such constant-power effects, a control scheme that can coordinate impedance behaviors of the two sub-converters is proposed. The idea is to reshape the lowfrequency negative impedance...

  2. A review of impedance measurements of whole cells.

    Science.gov (United States)

    Xu, Youchun; Xie, Xinwu; Duan, Yong; Wang, Lei; Cheng, Zhen; Cheng, Jing

    2016-03-15

    Impedance measurement of live biological cells is widely accepted as a label free, non-invasive and quantitative analytical method to assess cell status. This method is easy-to-use and flexible for device design and fabrication. In this review, three typical techniques for impedance measurement, i.e., electric cell-substrate impedance sensing, Impedance flow cytometry and electric impedance spectroscopy, are reviewed from the aspects of theory, to electrode design and fabrication, and applications. Benefiting from the integration of microelectronic and microfluidic techniques, impedance sensing methods have expanded their applications to nearly all aspects of biology, including living cell counting and analysis, cell biology research, cancer research, drug screening, and food and environmental safety monitoring. The integration with other techniques, the fabrication of devices for certain biological assays, and the development of point-of-need diagnosis devices is predicted to be future trend for impedance sensing techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Mechanical Impedance Modeling of Human Arm: A survey

    Science.gov (United States)

    Puzi, A. Ahmad; Sidek, S. N.; Sado, F.

    2017-03-01

    Human arm mechanical impedance plays a vital role in describing motion ability of the upper limb. One of the impedance parameters is stiffness which is defined as the ratio of an applied force to the measured deformation of the muscle. The arm mechanical impedance modeling is useful in order to develop a better controller for system that interacts with human as such an automated robot-assisted platform for automated rehabilitation training. The aim of the survey is to summarize the existing mechanical impedance models of human upper limb so to justify the need to have an improved version of the arm model in order to facilitate the development of better controller of such systems with ever increase in complexity. In particular, the paper will address the following issue: Human motor control and motor learning, constant and variable impedance models, methods for measuring mechanical impedance and mechanical impedance modeling techniques.

  4. [A Digital System for Bioimpedance and Electrical Impedance Tomography Measurement System].

    Science.gov (United States)

    Chen, Xiaoyan; Gao, Nana; Huang, Huafang

    2015-06-01

    A digital system for bioimpedance and electrical impedance tomography (EIT) measurement controlled by an ATmega16 microcontroller was constructed in our laboratory. There are eight digital electrodes using AD5933 to measure the impedance of the targets, and the data is transmitted to the computer wirelessly through nRF24L01. The structure of the system, circuit design, system testing, vitro measurements of animals' tissues and electrical impedance tomography are introduced specifically in this paper. The experimental results showed that the system relative error was 0.42%, and the signal noise ratio was 76.3 dB. The system not only can be used to measure the impedance by any two electrodes within the frequency of 1-100 kHz in a sweep scanning, but also can reconstruct the images of EIT. The animal experiments showed that the data was valid and plots were fitting with Cole-Cole theory. The testing verified the feasibility and effectiveness of the system. The images reconstructed of a salt-water tank are satisfactory and match with the actual distribution of the tank. The system improves the effectiveness of the front-end measuring signal and the stability of the system greatly.

  5. Resonant RF network antennas for large-area and large-volume inductively coupled plasma sources

    Science.gov (United States)

    Hollenstein, Ch; Guittienne, Ph; Howling, A. A.

    2013-10-01

    Large-area and large-volume radio frequency (RF) plasmas are produced by different arrangements of an elementary electrical mesh consisting of two conductors interconnected by a capacitor at each end. The obtained cylindrical and planar RF networks are resonant and generate very high RF currents. The input impedance of such RF networks shows the behaviour of an RLC parallel resonance equivalent circuit. The real impedance at the resonance frequency is of great advantage for power matching compared with conventional inductive devices. Changes in the RLC equivalent circuit during the observed E-H transition will allow future interpretation of the plasma-antenna coupling. Furthermore, high power transfer efficiencies are found during inductively coupled plasma (ICP) operation. For the planar RF antenna network it is shown that the E-H transition occurs simultaneously over the entire antenna. The underlying physics of these discharges induced by the resonant RF network antenna is found to be identical to that of the conventional ICP devices described in the literature. The resonant RF network antenna is a new versatile plasma source, which can be adapted to applications in industry and research.

  6. Great Lakes Energy Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, J. Iwan [Case Western Reserve Univ., Cleveland, OH (United States)

    2012-11-18

    The vision of the Great Lakes Energy Institute is to enable the transition to advanced, sustainable energy generation, storage, distribution and utilization through coordinated research, development, and education. The Institute will place emphasis on translating leading edge research into next generation energy technology. The Institute’s research thrusts focus on coordinated research in decentralized power generation devices (e.g. fuel cells, wind turbines, solar photovoltaic devices), management of electrical power transmission and distribution, energy storage, and energy efficiency.

  7. Great Salt Lake, Utah

    Science.gov (United States)

    Stephens, Doyle W.; Gardner, Joe F.

    1999-01-01

    This document is intended as a source of general information and facts about Great Salt Lake, Utah. This U.S. Geological Survey information sheet answers frequently asked questions about Great Salt Lake. Topics include: History, salinity, brine shrimp, brine flies, migratory birds, and recreation. Great Salt Lake, the shrunken remnant of prehistoric Lake Bonneville, has no outlet. Dissolved salts accumulate in the lake by evaporation. Salinity south of the causeway has ranged from 6 percent to 27 percent over a period of 22 years (2 to 7 times saltier than the ocean). The high salinity supports a mineral industry that extracts about 2 million tons of salt from the lake each year. The aquatic ecosystem consists of more than 30 species of organisms. Harvest of its best-known species, the brine shrimp, annually supplies millions of pounds of food for the aquaculture industry worldwide. The lake is used extensively by millions of migratory and nesting birds and is a place of solitude for people. All this occurs in a lake that is located at the bottom of a 35,000-square-mile drainage basin that has a human population of more than 1.5 million.

  8. Compact microstrip stepped impedance wideband bandpass filter

    Science.gov (United States)

    Li, Lin; Li, Zheng-Fan; Xia, H.-X.; Yang, J.-X.

    2011-08-01

    A novel wideband bandpass filter with a very compact size is presented in this article. Using a side-coupled stepped impedance resonator, wideband characteristics with adjustable centre frequency and 3-dB fractional bandwidth can be obtained easily. Finally, a filter sample is designed and fabricated to provide an experimental verification on the proposed topology. Good insertion/return losses, flat group delay, wide bandwidth as well as ultra compact size are achieved as demonstrated in both simulation and experiment, which makes this filter a very promising candidate for applications in future wideband communication system.

  9. Bioelectrical impedance analysis--part I

    DEFF Research Database (Denmark)

    Kyle, Ursula G; Bosaeus, Ingvar; De Lorenzo, Antonio D

    2004-01-01

    The use of bioelectrical impedance analysis (BIA) is widespread both in healthy subjects and patients, but suffers from a lack of standardized method and quality control procedures. BIA allows the determination of the fat-free mass (FFM) and total body water (TBW) in subjects without significant...... of the estimate. The determination of changes in body cell mass (BCM), extra cellular (ECW) and intra cellular water (ICW) requires further research using a valid model that guarantees that ECW changes do not corrupt the ICW. The use of segmental-BIA, multifrequency BIA, or bioelectrical spectroscopy in altered...

  10. Broadband Planar 5:1 Impedence Transformer

    Science.gov (United States)

    Ehsan, Negar; Hsieh, Wen-Ting; Moseley, Samuel H.; Wollack, Edward J.

    2015-01-01

    This paper presents a broadband Guanella-type planar impedance transformer that transforms so 50 omega to 10 omega with a 10 dB bandwidth of 1-14GHz. The transformer is designed on a flexible 50 micrometer thick polyimide substrate in microstrip and parallel-plate transmission line topologies, and is Inspired by the traditional 4:1 Guanella transformer. Back-to-back transformers were designed and fabricated for characterization in a 50 omega system. Simulated and measured results are in excellent agreement.

  11. Black hole jet power from impedance matching

    OpenAIRE

    Penna, Robert F.

    2015-01-01

    Black hole jet power depends on the angular velocity of magnetic field lines, $\\Omega_F$. Force-free black hole magnetospheres typically have $\\Omega_F/\\Omega_H \\approx 0.5$, where $\\Omega_H$ is the angular velocity of the horizon. We give a streamlined proof of this result using an extension of the classical black hole membrane paradigm. The proof is based on an impedance-matching argument between membranes at the horizon and infinity. Then we consider a general relativistic magnetohydrodyna...

  12. Coupled Transmission Lines as Impedance Transformer

    DEFF Research Database (Denmark)

    Jensen, Thomas; Zhurbenko, Vitaliy; Krozer, Viktor

    2007-01-01

    A theoretical investigation of the use of a coupled line section as an impedance transformer is presented. We show how to properly select the terminations of the coupled line structures for effective matching of real and complex loads in both narrow and wide frequency ranges. The corresponding....... Wideband matching performance with relative bandwidth beyond 100% and return loss > 20 dB is demonstrated both theoretically and experimentally. Good agreement is achieved between the measured and predicted performance of the coupled line transformer section....

  13. Real-Time Thevenin Impedance Computation

    DEFF Research Database (Denmark)

    Sommer, Stefan Horst; Jóhannsson, Hjörtur

    2013-01-01

    Stable and secure operation of power systems becomes increasingly difficult when a large share of the power production is based on distributed and non-controllable renewable energy sources. Real-time stability assessment is dependent on very fast computation of different properties of the grid...... operating state, and strict time constraints are difficult to adhere to as the complexity of the grid increases. Several suggested approaches for real-time stability assessment require Thevenin impedances to be determined for the observed system conditions. By combining matrix factorization, graph reduction...... grids at millisecond time scale....

  14. LHC MD 232: Longitudinal Impedance Evaluation

    CERN Document Server

    Esteban Muller, Juan; Baudrenghien, Philippe; Shaposhnikova, Elena; CERN. Geneva. ATS Department

    2017-01-01

    The aim of the MDstudies presented here was to evaluate the imaginary part of the longitudinal impedance of the LHC by means of synchrotron frequency shift measurements. Single bunches with similar longitudinal emittance but different intensities were studied at flat top. Based on the beam parameters, a maximum shift of about 0.2 Hz was expected between the different bunches. A detailed analysis still needs to be carried out to determine the measured synchrotron frequency shift. The measurements took place between 8:00 p.m. on 26th and 2:00 a.m. on 27th July 2016

  15. Transferring human impedance regulation skills to robots

    CERN Document Server

    Ajoudani, Arash

    2016-01-01

    This book introduces novel thinking and techniques to the control of robotic manipulation. In particular, the concept of teleimpedance control as an alternative method to bilateral force-reflecting teleoperation control for robotic manipulation is introduced. In teleimpedance control, a compound reference command is sent to the slave robot including both the desired motion trajectory and impedance profile, which are then realized by the remote controller. This concept forms a basis for the development of the controllers for a robotic arm, a dual-arm setup, a synergy-driven robotic hand, and a compliant exoskeleton for improved interaction performance.

  16. Electroconductive qualities of the membranes МС-40 and МА-41, researched by the method of impedance high-frequency spectroscopy

    Directory of Open Access Journals (Sweden)

    S. I. Niftaliev

    2016-01-01

    Full Text Available One of the most important factors defining the complex of operational characteristics of heterogeneous ion-exchange membranes that represent a composite material is their structure. Composite material electroconductivity depends on the nature of phases setting the system and on their relative position. Impedance spectroscopy is one of the effective methods of structure definition and electrochemical characteristics not only of the composite material generaly but also the phases which it consists of. In this paper by the method of impedance spectroscopy the electrochemical characteristics of the heterogeneous ion-exchange membranes МС-40 (H+, Na+, К+, NH4+ - forms and МА-41 (Cl- and NO3- - forms in the range of the alternating current frequencies 100 KHz – 20 MHz are researched. The comparison of the contact and contact-differential ways of measuring membrane impedance is done. It is shown that in the case of impedance contact measuring of the sample the borders “electrode/membrane” influence the electrochemical impedance system spectrum greatly. In connection with this the contact-differential variant of the experimental procedure in the impedance measuring of the membrane system is more preferable. The interpretation of the received electrochemical impedance spectra in terms of the composite material conductivity is given. Basing on the method of equivalent circuits it is suggested representing the impedance of the heterogeneous ion-exchange membrane as a sum of pure resistance (resistance of ion-exchanger particles, sequentially connected with the impedance of the dielectric layers (resistance and capacity of polyethylene and dissolvent. The analysis of the spectra of electrochemical impedance of ion-exchange membranes in different ion forms showed that the quantity of the semicircle locus impedance radius is inversely proportional to the coefficient of counter-ion diffusion and directly proportional to the part of the

  17. Cyber Network Mission Dependencies

    Science.gov (United States)

    2015-09-18

    or she must make. Network Mapping System ( NeMS ) is a software-based tool created by the Lawrence Livermore National Laboratory to discover and map...network assets in support of cyber situational awareness [10]. NeMS combines both active probes and passive monitoring of network data to map the network...security settings in order to maximize efficiency without disrupting network activities. Tests of NeMS in control networks yielded great results, as

  18. Normal incidence sound transmission loss evaluation by upstream surface impedance measurements.

    Science.gov (United States)

    Panneton, Raymond

    2009-03-01

    A method is developed to obtain the normal incidence sound transmission loss of noise control elements used in piping systems from upstream surface impedance measurements only. The noise control element may be a small material specimen in an impedance tube, a sealing part in an automotive hollow body network, an expansion chamber, a resonator, or a muffler. The developments are based on a transfer matrix (four-pole) representation of the noise control element and on the assumption that only plane waves propagate upstream and downstream the element. No assumptions are made on its boundary conditions, dimensions, shape, and material properties (i.e., the element may be symmetrical or not along its thickness, homogeneous or not, isotropic or not). One-load and two-load procedures are also proposed to identify the transfer matrix coefficients needed to obtain the true transmission loss of the tested element. The method can be used with a classical two-microphone impedance tube setup (i.e., no additional downstream tube and downstream acoustical measurements). The method is tested on three different noise control elements: two impedance tube multilayered specimens and one expansion chamber. The results found using the developed method are validated using numerical simulations.

  19. Anisotropic impedance surfaces for enhanced antenna isolation

    Science.gov (United States)

    Miragliotta, Joseph A.; Shrekenhamer, David; Sievenpiper, Daniel F.

    2015-09-01

    Anisotropic impedance surfaces, which include metasurfaces and high impedance surfaces (HIS), can be designed to control the amplitude and propagation direction of surface electromagnetic waves and are an effective means to enhance the isolation between antennas that share a common ground plane. To date, the majority of metastructures that have been designed for antenna isolation have relied on an isotropic distribution of unit cells that possess a stop band that inhibits the propagation of surface waves between neighboring antennas. A less common approach to isolation has been through the design of a metasurface that enables the re-direction of surface waves away from the location of the antenna structure, which effectively limits the coupling. In this paper, we discuss results from our computational investigation associated with improving antenna isolation through the use of an anisotropic metastructure. Simulated results associated with the isolation performance of two simple, but similar, anisotropic structures are compared to the corresponding results from a broadband magnetic radar absorbing materials (magRAM).

  20. Study on Impedance Characteristics of Aircraft Cables

    Directory of Open Access Journals (Sweden)

    Weilin Li

    2016-01-01

    Full Text Available Voltage decrease and power loss in distribution lines of aircraft electric power system are harmful to the normal operation of electrical equipment and may even threaten the safety of aircraft. This study investigates how the gap distance (the distance between aircraft cables and aircraft skin and voltage frequency (variable frequency power supply will be adopted for next generation aircraft will affect the impedance of aircraft cables. To be more precise, the forming mechanism of cable resistance and inductance is illustrated in detail and their changing trends with frequency and gap distance are analyzed with the help of electromagnetic theoretical analysis. An aircraft cable simulation model is built with Maxwell 2D and the simulation results are consistent with the conclusions drawn from the theoretical analysis. The changing trends of the four core parameters of interest are analyzed: resistance, inductance, reactance, and impedance. The research results can be used as reference for the applications in Variable Speed Variable Frequency (VSVF aircraft electric power system.

  1. Great software debates

    CERN Document Server

    Davis, A

    2004-01-01

    The industry’s most outspoken and insightful critic explains how the software industry REALLY works. In Great Software Debates, Al Davis, shares what he has learned about the difference between the theory and the realities of business and encourages you to question and think about software engineering in ways that will help you succeed where others fail. In short, provocative essays, Davis fearlessly reveals the truth about process improvement, productivity, software quality, metrics, agile development, requirements documentation, modeling, software marketing and sales, empiricism, start-up financing, software research, requirements triage, software estimation, and entrepreneurship.

  2. Idiopathic great saphenous phlebosclerosis.

    Directory of Open Access Journals (Sweden)

    Ahmadreza Jodati

    2013-06-01

    Full Text Available Arterial sclerosis has been extensively described but reports on venous sclerosis are very sparse. Phlebosclerosis refers to the thickening and hardening of the venous wall. Despite its morphological similarities with arteriosclerosis and potential morbid consequences, phlebosclerosis has gained only little attention. We report a 72 year old male with paralysis and atrophy of the right leg due to childhood poliomyelitis who was referred for coronary artery bypass surgery. The great saphenous vein, harvested from the left leg, showed a hardened cord-like obliterated vein. Surprisingly, harvested veins from the atrophic limb were normal and successfully used for grafting.

  3. Vulnerability of network of networks

    Science.gov (United States)

    Havlin, S.; Kenett, D. Y.; Bashan, A.; Gao, J.; Stanley, H. E.

    2014-10-01

    Our dependence on networks - be they infrastructure, economic, social or others - leaves us prone to crises caused by the vulnerabilities of these networks. There is a great need to develop new methods to protect infrastructure networks and prevent cascade of failures (especially in cases of coupled networks). Terrorist attacks on transportation networks have traumatized modern societies. With a single blast, it has become possible to paralyze airline traffic, electric power supply, ground transportation or Internet communication. How, and at which cost can one restructure the network such that it will become more robust against malicious attacks? The gradual increase in attacks on the networks society depends on - Internet, mobile phone, transportation, air travel, banking, etc. - emphasize the need to develop new strategies to protect and defend these crucial networks of communication and infrastructure networks. One example is the threat of liquid explosives a few years ago, which completely shut down air travel for days, and has created extreme changes in regulations. Such threats and dangers warrant the need for new tools and strategies to defend critical infrastructure. In this paper we review recent advances in the theoretical understanding of the vulnerabilities of interdependent networks with and without spatial embedding, attack strategies and their affect on such networks of networks as well as recently developed strategies to optimize and repair failures caused by such attacks.

  4. Light manipulation with flat and conformal inhomogeneous dispersive impedance sheets: an efficient FDTD modeling.

    Science.gov (United States)

    Jafar-Zanjani, Samad; Cheng, Jierong; Mosallaei, Hossein

    2016-04-10

    An efficient auxiliary differential equation method for incorporating 2D inhomogeneous dispersive impedance sheets in the finite-difference time-domain solver is presented. This unique proposed method can successfully solve optical problems of current interest involving 2D sheets. It eliminates the need for ultrafine meshing in the thickness direction, resulting in a significant reduction of computation time and memory requirements. We apply the method to characterize a novel broad-beam leaky-wave antenna created by cascading three sinusoidally modulated reactance surfaces and also to study the effect of curvature on the radiation characteristic of a conformal impedance sheet holographic antenna. Considerable improvement in the simulation time based on our technique in comparison with the traditional volumetric model is reported. Both applications are of great interest in the field of antennas and 2D sheets.

  5. Numerical analysis on effective electric field penetration depth for interdigital impedance sensor

    Science.gov (United States)

    Kim, Chon-ung; Li, Guofeng; Li, Jie; Jong, Hakchol; Ro, Cholwu; Song, Yunho; Pak, Gilhung; Im, Songil

    2013-03-01

    Interdigital (finger-like) electrodes are widely used for electrical impedance and capacitance tomography of composite dielectric materials and complex insulating structures. Because of their advantages, they are now effectively introduced as capacitance sensors into a variety of industrial branches, agriculture, medical science, biological engineering, military branches, etc. In order to effectively apply the so-called interdigital impedance sensors in practice, of great importance is to optimize the sensor design parameters such as the electric field penetration depth, signal strength and so on. The general design principles of the interdigital capacitance sensor have been discussed for a long time by many researchers. However, there is no consensus on the definition of the effective electric field penetration depth of interdigital electrode. This paper discusses how to determine the effective electric field penetration depth of interdigital sensor on the basis of the refractive principle of electric field intensity and the FEM analyses of electric field distribution and capacitance for the sensor model.

  6. A cable-free impedance and gain measurement technique for electrically small antennas

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Zhang, Jiaying; Breinbjerg, Olav

    2010-01-01

    are represented in terms of spherical wave expansions (SWEs), and the propagation is accounted for by a transmission formula. In this paper the measurement results by the proposed technique will be presented for several AUTs, including a standard gain horn antenna, a monopole antenna, and an electrically small......Impedance and gain measurements for electrically small antennas represent a great challenge due to influences of the feeding cable. The leaking current along the cable and scattering effects are two main issues caused by the feed line. In this paper, a novel cable-free antenna impedance and gain...... measurement technique for electrically small antennas is proposed. The antenna properties are extracted by measuring the signal scattered by the antenna under test (AUT), when it is loaded with three known loads. The technique is based on a rigorous electromagnetic model where the probe and AUT...

  7. Anti-islanding Protection of Distributed Generation Using Rate of Change of Impedance

    Science.gov (United States)

    Shah, Pragnesh; Bhalja, Bhavesh

    2013-08-01

    Distributed Generation (DG), which is interlinked with distribution system, has inevitable effect on distribution system. Integrating DG with the utility network demands an anti-islanding scheme to protect the system. Failure to trip islanded generators can lead to problems such as threats to personnel safety, out-of-phase reclosing, and degradation of power quality. In this article, a new method for anti-islanding protection based on impedance monitoring of distribution network is carried out in presence of DG. The impedance measured between two phases is used to derive the rate of change of impedance (dz/dt), and its peak values are used for final trip decision. Test data are generated using PSCAD/EMTDC software package and the performance of the proposed method is evaluated in MatLab software. The simulation results show the effectiveness of the proposed scheme as it is capable to detect islanding condition accurately. Subsequently, it is also observed that the proposed scheme does not mal-operate during other disturbances such as short circuit and switching event.

  8. Study on electrical impedance matching for broadband ultrasonic transducer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon Woo [University of Science and Technology, Daejeon (Korea, Republic of); Kim, Ki Bok [Korea Research Institute of Standards and Science, Center for Safety Measurement, Daejeon (Korea, Republic of); Baek, Kwang Sae [Elache Co., Busan (Korea, Republic of)

    2017-02-15

    Ultrasonic transducers with high resolution and resonant frequency are required to detect small defects (less than hundreds of μm) by ultrasonic testing. The resonance frequency and resolution of an ultrasonic transducer are closely related to the thickness of piezo-electric materials, backing materials, and the electric impedance matching technique. Among these factors, electrical impedance matching plays an important role because it can reduce the loss and reflection of ultrasonic energy differences in electrical impedance between an ultrasonic transducer and an ultrasonic defects detecting system. An LC matching circuit is the most frequently used electric matching method. It is necessary for the electrical impedance of an ultrasonic transducer to correspond to approximately 50 Ω to compensate the difference in electrical impedance between both connections. In this study, a 15 MHz immersion ultrasonic transducer was fabricated and an LC electrical impedance circuit was applied to that for having broad-band frequency characteristic.

  9. Transverse impedance measurement in RHIC and the AGS

    Energy Technology Data Exchange (ETDEWEB)

    Biancacci, Nicolo [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Dutheil, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Liu, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Mernick, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; White, S. M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-05-12

    The RHIC luminosity upgrade program aims for an increase of the polarized proton luminosity by a factor 2. To achieve this goal a significant increase in the beam intensity is foreseen. The beam coupling impedance could therefore represent a source of detrimental effects for beam quality and stability at high bunch intensities. For this reason it is essential to quantify the accelerator impedance budget and the major impedance sources, and possibly cure them. In this MD note we summarize the results of the 2013 transverse impedance measurements in the AGS and RHIC. The studies have been performed measuring the tune shift as a function of bunch intensity and deriving the total accelerator machine transverse impedance. For RHIC, we could obtain first promising results of impedance localization measurements as well.

  10. Ecosystem services in the Great Lakes

    Science.gov (United States)

    Steinman, Alan D.; Cardinale, Bradley J; Munns Jr, Wayne R; Ogdahl, Mary E.; Allan, David J; Angadi, Ted; Bartlett, Sarah; Brauman, Kate; Byappanahalli, Muruleedhara; Doss, Matt; Dupont, Diane; Johns, Annie; Kashian, Donna; Lupi, Frank; McIntyre, Peter B.; Miller, Todd; Moore, Michael P.; Muenich, Rebecca Logsdon; Poudel, Rajendra; Price, James; Provencher, Bill; Rea, Anne; Read, Jennifer; Renzetti, Steven; Sohngen, Brent; Washburn, Erica

    2017-01-01

    A comprehensive inventory of ecosystem services across the entire Great Lakes basin is currently lacking and is needed to make informed management decisions. A greater appreciation and understanding of ecosystem services, including both use and non-use services, may have avoided misguided resource management decisions in the past that resulted in negative legacies inherited by future generations. Given the interest in ecosystem services and lack of a coherent approach to addressing this topic in the Great Lakes, a summit was convened involving 28 experts working on various aspects of ecosystem services in the Great Lakes. The invited attendees spanned a variety of social and natural sciences. Given the unique status of the Great Lakes as the world's largest collective repository of surface freshwater, and the numerous stressors threatening this valuable resource, timing was propitious to examine ecosystem services. Several themes and recommendations emerged from the summit. There was general consensus that: 1) a comprehensive inventory of ecosystem services throughout the Great Lakes is a desirable goal but would require considerable resources; 2) more spatially and temporally intensive data are needed to overcome our data gaps, but the arrangement of data networks and observatories must be well-coordinated; 3) trade-offs must be considered as part of ecosystem services analyses; and 4) formation of a Great Lakes Institute for Ecosystem Services, to provide a hub for research, meetings, and training is desirable. Several challenges also emerged during the summit, which are discussed.

  11. Human Blood Cell Sensing with Platinum Black Electroplated Impedance Sensor

    OpenAIRE

    Zheng, Siyang; Nandra, Mandheerej S.; Tai, Yu-Chong

    2007-01-01

    AC impedance sensing is an important method for biological cell analysis in flow cytometry. For micro impedance cell sensors, downsizing electrodes increases the double layer impedance of the metal-electrolyte interface, thus leaves no sensing zone in frequency domain and reduces the sensitivity significantly. We proposed using platinum black electroplated electrodes to solve the problem. In this paper, using this technique we demonstrated human blood cell sensing with high signal to noise ra...

  12. Application of Extended Elastic Impedance (EEI) to improve Reservoir Characterization

    OpenAIRE

    Gharaee Shahri, Seyed Ali

    2013-01-01

    The Extended Elastic Impedance (EEI) as a seismic attribute was first introduced by Whitcombe (2002) as a method for fluid and lithology prediction. EEI is the application of angle rotation in the conventional acoustic impedance under certain approximation. It essentially works by projecting intercept and gradient together with different angles which highlights different features. EEI has capability to estimate elastic parameters such as S-wave impedance, Vp/Vs ratio, bulk modulus, shear mod...

  13. Application of alternating current impedance to fuel cell modeling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, T.E.

    1999-05-02

    AC impedance has provided a useful diagnostic tool in the Los Alamos polymer electrolyte fuel cell (PEFC) program. The author reviews the techniques he has used in ac impedance modeling. These techniques include equation implementation, model simplification and verification, least squares fitting, application of two-dimensional Laplace equation solvers handling complex interfacial boundary conditions, and interpretation of impedance features. The separate features of the complete electrode model are explained by analytic examples.

  14. Accessibility to Nodes of Interest: A Practical Application of the Various Forms of the Impedance Curves

    Directory of Open Access Journals (Sweden)

    GIOACCHINO DE CANDIA

    2014-06-01

    Full Text Available Impedance is, in territorial statistics, the greater or lesser difficulty of a territory to be served/provided with adequate infrastructure and related services, useful for the improvement of the resident’s quality of life. In the opposite, a greater impedance implies a low attractiveness of the territory for the establishment of new productive activities. The purpose of this research is to provide a picture as comprehensive as possible of the existing methodology for the elaboration of impedance, providing practical applications in relation to the Tuscan territory. The methodology used in this paper is part of the category of models called “gravitational”, which are characterized by the denominator of the equation (index that expresses the impediment in relation to accessibility between points in geographic space. In this case, the calculations have been made considering the cost of travel, which depends on the distance or travel time between points located on the transportation network that represent the points of departure and arrival. The processing affect the function of impedance by elaborating linear, exponential and logistic forms for the infrastructures related to hospitals with emergency rooms, upper secondary schools, airports, and railway stations. Processing separately covered the metropolitan municipality of Florence. The research highlights the main existing methodologies in relation to determining accessibility (attractiveness of the territories, according to their infrastructural facilities and services. The analysis reveals the strengths and weaknesses, as well as the salient features of the equation used. In this sense, the research has produced a real benchmark between different approaches, using from time to time the variation of the impedance function.

  15. Esophageal impedance baseline according to different time intervals

    Directory of Open Access Journals (Sweden)

    Ummarino Dario

    2012-06-01

    Full Text Available Abstract Background The impedance baseline has been shown to reflect esophageal integrity, and to be decreased in patients with esophagitis. However, different methods for the determination of the impedance baseline have not been compared. Methods The median impedance baseline was calculated in 10 consecutive multichannel intraluminal impedance recordings in children with non-erosive reflux disease. All children underwent an endoscopy with a biopsy as part of the clinical work-up to exclude esophagitis. The impedance baseline was obtained both by including and excluding all impedance episodes (IE; reflux, swallows and gas episodes during the full recording, and during the first 1-minute period without an IE every hour (method 1, every 2 hours (method 2 or every 4 hours (method 3. The impedance baseline obtained during the full recording was set at 100%, and the variation (difference in impedance baseline for the different methods and variability (difference in impedance baseline during one analysis period were assessed. Results None of the participants had esophagitis. The mean difference over the six channels between the impedance baseline over the total recording with and without IE was approximately 2.5%, and comparable for each channel (range 0.47% to 5.55%. A mean of 1,028 IEs were excluded in each tracing, and it took between 4 and 24 hours to delete all events in one tracing. The difference in the impedance baseline obtained with and without IEs was mainly caused by the gas episodes in the upper channels and swallows in the lower channels. The median impedance baseline according to the three one-minute analysis methods was comparable to the median impedance baseline according to the 24 hour analysis. Conclusions The automatic determination of the median impedance baseline over the total tracing including IEs is an adequate method. In isolated tracings with numerous IEs, the calculation of the median impedance baseline over one minute

  16. Impedance of the PEP-II DIP screen

    Energy Technology Data Exchange (ETDEWEB)

    Ng, C.-K. [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Weiland, T.

    1996-08-01

    The vacuum chamber of a storage ring normally consists of periodically spaced pumping slots. The longitudinal impedance of slots are analyzed in this paper. It is found that although the broad-band impedance is tolerable, the narrow-band impedance, as a consequence of the periodicity of the slots, may exceed the stability limit given by natural damping with no feedback system on. Based on this analysis, the PEP-II distributed-ion-pump (DIP) screen uses long grooves with hidden holes cut halfway to reduce both the broad-band and narrow-band impedances. (author)

  17. Impedance Localization Measurements using AC Dipoles in the LHC

    CERN Document Server

    Biancacci, Nicolo; Papotti, Giulia; Persson, Tobias; Salvant, Benoit; Tomás, Rogelio

    2016-01-01

    The knowledge of the LHC impedance is of primary importance to predict the machine performance and allow for the HL-LHC upgrade. The developed impedance model can be benchmarked with beam measurements in order to assess its validity and limit. This is routinely done, for example, moving the LHC collimator jaws and measuring the induced tune shift. In order to localize possible unknown impedance sources, the variation of phase advance with intensity between beam position monitors can be measured. In this work we will present the impedance localization measurements performed at injection in the LHC using AC dipoles as exciter as well as the underlying theory.

  18. The Great Scientists

    Science.gov (United States)

    Meadows, Jack

    1989-11-01

    This lively history of the development of science and its relationship to society combines vivid biographies of twelve pivotal scientists, commentary on the social and historical events of their time, and over four hundred illustrations, including many in color. The biographies span from classical times to the Atomic Age, covering Aristotle, Galileo, Harvey, Newton, Lavoisier, Humboldt, Faraday, Darwin, Pasteur, Curie, Freud, and Einstein. Through the biographies and a wealth of other material, the volume reveals how social forces have influenced the course of science. Along with the highly informative color illustrations, it contains much archival material never before published, ranging from medieval woodcuts, etchings from Renaissance anatomy texts, and pages from Harvey's journal, to modern false-color x-rays and infrared photographs of solar flares. A beautifully-designed, fact-filled, stimulating work, The Great Scientists will fascinate anyone with an interest in science and how history can influence scientific discovery.

  19. Great Britain at CERN

    CERN Document Server

    2006-01-01

    From 14 to 16 November 2006 Administration Building, Bldg. 60/61 - ground and 1st floor 09.30 - 17.30 Fifteen companies will present their latest technologies at the 'Great Britain at CERN' exhibition. British industry will exhibit products and technologies related to the field of particle physics. The main fields represented will be computing technologies, electrical engineering, electronics, mechanical engineering, vacuum & low temperature technologies and particle detectors. The exhibition is organised by BEAMA Exhibitions (the British Electrotechnical and Allied Manufacturers Association). Below you will find: a list of the exhibitors. A detailed programme will be available in due course: from your Departmental secretariat, from the Reception information desk, Building 33, at the exhibition itself. A detailed list of the companies is available at the following FI link: http://fi-dep.web.cern.ch/fi-dep/structure/memberstates/exhibitions_visits.htm LIST OF EXHIBITORS 3D Metrics Alma...

  20. Great Britain at CERN

    CERN Document Server

    2006-01-01

    From 14 to 16 November 2006 Administration Building, Bldg. 60/61 - ground and 1st floor 09.30 - 17.30 Fifteen companies will present their latest technologies at the 'Great Britain at CERN' exhibition. British industry will exhibit products and technologies related to the field of particle physics. The main fields represented will be computing technologies, electrical engineering, electronics, mechanical engineering, vacuum & low temperature technologies and particle detectors. The exhibition is organised by BEAMA Exhibitions (the British Electrotechnical and Allied Manufacturers Association). Below you will find: a list of the exhibitors. A detailed programme will be available in due course: from your Departmental secretariat, from the Reception information desk, Building 33, at the exhibition itself. A detailed list of the companies is available at the following FI link: http://fi-dep.web.cern.ch/fi-dep/structure/memberstates/exhibitions_visits.htm LIST OF EXHIBITORS 3D Metrics Almat...

  1. Bioelectrical impedance analysis. What does it measure?

    Science.gov (United States)

    Schoeller, D. A.

    2000-01-01

    Bioelectrical impedance analysis (BIA) has been proposed for measuring fat-free mass, total body water, percent fat, body cell mass, intracellular water, and extracellular water: a veritable laboratory in a box. Although it is unlikely that BIA is quite this versatile, correlations have been demonstrated between BIA and all of these body compartments. At the same time, it is known that all of the compartments are correlated among themselves. Because of this, it is difficult to determine whether BIA is specific for any or all of these compartments. To investigate this question, we induced acute changes in total body water and its compartments over a 3-h period. Using this approach, we demonstrated that multifrequency BIA, using the Cole-Cole model to calculate the zero frequency and infinite frequency resistance, measures extracellular and intracellular water.

  2. Multilayer tube impedance and external radiation

    Directory of Open Access Journals (Sweden)

    M. Ivanyan

    2008-08-01

    Full Text Available The paper describes a method for calculating the longitudinal and transverse impedances of the laminated round pipe with many layers of different materials. The charge is moving along the pipe axis with arbitrary constant velocity. The study is based on the field-matching technique applied for the arbitrary harmonic of the electromagnetic field. The matrix formalism has been developed to describe the field transitions through the subsequent layers that allow coupling the electromagnetic fields inside and outside the pipe. The number of equations to be solved is then reduced to four algebraic equations. The solutions and ultrarelativistic limits for the field harmonics in the inner and outer regions of the pipe are derived.

  3. Corrosion Study Using Electrochemical Impedance Spectroscopy

    Science.gov (United States)

    Farooq, Muhammad Umar

    2003-01-01

    Corrosion is a common phenomenon. It is the destructive result of chemical reaction between a metal or metal alloy and its environment. Stainless steel tubing is used at Kennedy Space Center for various supply lines which service the orbiter. The launch pads are also made of stainless steel. The environment at the launch site has very high chloride content due to the proximity to the Atlantic Ocean. Also, during a launch, the exhaust products in the solid rocket boosters include concentrated hydrogen chloride. The purpose of this project was to study various alloys by Electrochemical Impedance Spectroscopy in corrosive environments similar to the launch sites. This report includes data and analysis of the measurements for 304L, 254SMO and AL-6XN in primarily neutral 3.55% NaCl. One set of data for 304L in neutral 3.55%NaCl + 0.1N HCl is also included.

  4. Great Wall of China

    Science.gov (United States)

    2001-01-01

    This ASTER sub-image covers a 12 x 12 km area in northern Shanxi Province, China, and was acquired January 9, 2001. The low sun angle, and light snow cover highlight a section of the Great Wall, visible as a black line running diagonally through the image from lower left to upper right. The Great Wall is over 2000 years old and was built over a period of 1000 years. Stretching 4500 miles from Korea to the Gobi Desert it was first built to protect China from marauders from the north.This image is located at 40.2 degrees north latitude and 112.8 degrees east longitude.Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of International Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products. Dr. Anne Kahle at NASA's Jet Propulsion Laboratory, Pasadena, Calif., is the U.S. Science team leader; Moshe Pniel of JPL is the project manager. ASTER is the only high resolution imaging sensor on Terra. The primary goal of the ASTER mission is to obtain high-resolution image data in 14 channels over the entire land surface, as well as black and white stereo images. With revisit time of between 4 and 16 days, ASTER will provide the capability for repeat coverage of changing areas on Earth's surface.The broad spectral coverage and high spectral resolution of ASTER will provide scientists in numerous disciplines with critical information for surface mapping, and monitoring dynamic conditions and temporal change. Example applications are: monitoring glacial advances and retreats, monitoring potentially active volcanoes, identifying crop stress, determining cloud morphology and physical properties, wetlands Evaluation, thermal pollution monitoring, coral reef degradation, surface temperature mapping of soils and geology, and measuring surface

  5. Virtual Impedance Based Fault Current Limiters for Inverter Dominated AC Microgrids

    DEFF Research Database (Denmark)

    Lu, Xiaonan; Wang, Jianhui; Guerrero, Josep M.

    2017-01-01

    In this paper, a virtual impedance based fault current limiter (VI-FCL) is proposed for islanded microgrids comprised of multiple inverter interfaced distributed generators (DGs). Considering the increased fault current capability induced by high penetration of renewable energy sources (RESs), FCLs...... are employed to suppress the fault current and the subsequent oscillation and even instability in the modern distribution network with microgrids. In this study, rather than involving extra hardware equipment, the functionality of FCL is achieved in the control diagram of DG inverters by employing additional...... virtual impedance control loops. The proposed VI-FCL features flexible and low-cost implementation and can effectively suppress the fault current and the oscillation in the following fault restoration process in AC microgrids. The systematic model of the inverter dominated AC microgrid is derived...

  6. A High Input Impedance Low Noise Integrated Front-End Amplifier for Neural Monitoring.

    Science.gov (United States)

    Zhou, Zhijun; Warr, Paul A

    2016-12-01

    Within neural monitoring systems, the front-end amplifier forms the critical element for signal detection and pre-processing, which determines not only the fidelity of the biosignal, but also impacts power consumption and detector size. In this paper, a novel combined feedback loop-controlled approach is proposed to compensate for input leakage currents generated by low noise amplifiers when in integrated circuit form alongside signal leakage into the input bias network. This loop topology ensures the Front-End Amplifier (FEA) maintains a high input impedance across all manufacturing and operational variations. Measured results from a prototype manufactured on the AMS 0.35 [Formula: see text] CMOS technology is provided. This FEA consumes 3.1 [Formula: see text] in 0.042 [Formula: see text], achieves input impedance of 42 [Formula: see text], and 18.2 [Formula: see text] input-referred noise.

  7. Relating membrane potential to impedance spectroscopy

    Directory of Open Access Journals (Sweden)

    Eugen Gheorghiu

    2011-12-01

    Full Text Available Non-invasive, label-free assessment of membrane potential of living cells is still a challenging task. The theory linking membrane potential to the low frequency α dispersion exhibited by suspensions of spherical shelled particles (presenting a net charge distribution on the inner side of the shell has been pioneered in our previous studies with emphasis on the permittivity spectra. Whereas α dispersion is related to a rather large variation exhibited by the permittivity spectrum, we report that the related decrement presented by the impedance magnitude spectrum is either extremely small, or occurs (for large cells at very small frequencies (~mHz explaining the lack of experimental bioimpedance data on the matter. We stress that appropriate choice of the parameters (as revealed by the microscopic model may enable access to membrane potential as well as to other relevant parameters when investigating living cells and charged lipid vesicles. We analyse the effect on the low frequency of the permittivity and impedance spectra of: I. Parameters pertaining to cell membrane i.e. (i membrane potential (through the amount of the net charge on the inner side of the membrane, (ii size of the cells/vesicles, (iii conductivity of the membrane; II. Parameters of the extra cellular medium (viscosity and conductivity. The applicability of the study has far reaching implications for basic (life sciences (providing non-invasive access to the dynamics of relevant cell parameters as well as for biosensing applications, e.g. assessment of cytotoxicity of a wide range of stimuli. doi:10.5617/jeb.214 J Electr Bioimp, vol. 2, pp. 93-97, 2011

  8. Comparison of Howland and General Impedance Converter (GIC) circuit based current sources for bio-impedance measurements

    Science.gov (United States)

    Qureshi, T. R.; Chatwin, C. R.; Huber, N.; Zarafshani, A.; Tunstall, B.; Wang, Wei

    2010-04-01

    The current source is a key component in bio-impedance measurement systems. The accuracy of the current source can be measured in terms of its output impedance together with other parameters, with certain applications demanding extremely high output impedance. This paper presents an investigation and comparison of different current source designs based on the Enhanced Howland circuit combined with a General Impedance Converter (GIC) circuit using both ideal and non-ideal operational amplifiers. Under differing load conditions two different settings of the GIC are evaluated and the results are compared to show its performance settings. Whilst the study has shown that over a wide bandwidth (i.e. 100Hz - 100MHz) the output impedance is limited, operation over a more limited range offers output impedance in the Giga-ohm range, which can be considered as being infinite.

  9. Electrical impedance spectroscopy for measuring the impedance response of carbon-fiber-reinforced polymer composite laminates

    KAUST Repository

    Almuhammadi, Khaled

    2017-02-16

    Techniques that monitor the change in the electrical properties of materials are promising for both non-destructive testing and structural health monitoring of carbon-fiber-reinforced polymers (CFRPs). However, achieving reliable monitoring using these techniques requires an in-depth understanding of the impedance response of these materials when subjected to an alternating electrical excitation, information that is only partially available in the literature. In this work, we investigate the electrical impedance spectroscopy response at various frequencies of laminates chosen to be representative of classical layups employed in composite structures. We clarify the relationship between the frequency of the electrical current, the conductivity of the surface ply and the probing depth for different CFRP configurations for more efficient electrical signal-based inspections. We also investigate the effect of the amplitude of the input signal.

  10. Determination of beam coupling impedance in the frequency domain

    Energy Technology Data Exchange (ETDEWEB)

    Niedermayer, Uwe

    2016-07-01

    The concept of beam coupling impedance describes the electromagnetic interaction of uniformly moving charged particles with their surrounding structures in the Frequency Domain (FD). In synchrotron accelerators, beam coupling impedances can lead to beam induced component heating and coherent beam instabilities. Thus, in order to ensure the stable operation of a synchrotron, its impedances have to be quantified and their effects have to be controlled. Nowadays, beam coupling impedances are mostly obtained by Fourier transform of wake potentials, which are the results of Time Domain (TD) simulations. However, at low frequencies, low beam velocity, or for dispersive materials, TD simulations become unhandy. In this area, analytical calculations of beam coupling impedance in the FD, combined with geometry approximations, are still widely used. This thesis describes the development of two electromagnetic field solvers to obtain the beam coupling impedance directly in the FD, where the beam velocity is only a parameter and dispersive materials can be included easily. One solver is based on the Finite Integration Technique (FIT) on a staircase mesh. It is implemented both in 2D and 3D. However, the staircase mesh is inefficient on curved structures, which is particularly problematic for the modeling of a dipole source, that is required for the computation of the transverse beam coupling impedance. This issue is overcome by the second solver developed in this thesis, which is based on the Finite Element Method (FEM) on an unstructured triangular mesh. It is implemented in 2D and includes an optional Surface Impedance Boundary Condition (SIBC). Thus, it is well suited for the computation of longitudinal and transverse impedances of long beam pipe structures of arbitrary cross-section. Besides arbitrary frequency and beam velocity, also dispersive materials can be chosen, which is crucial for the computation of the impedance of ferrite kicker magnets. Numerical impedance

  11. A Novel Grid Impedance Estimation Technique based on Adaptive Virtual Resistance Control Loop Applied to Distributed Generation Inverters

    DEFF Research Database (Denmark)

    Ghzaiel, Walid; Jebali-Ben Ghorbal, Manel; Slama-Belkhodja, Ilhem

    2013-01-01

    The penetration of the distributed power generation systems (DPGSs) based on renewable sources (PV, WT) is strongly dependent on the quality of the power injected to the utility grid. However, the grid impedance variation, mainly caused by grid faults somewhere in the electric network, can degrade...... and to take the decision of either keep the DG connected, or disconnect it from the utility grid. The proposed method is based on a fast and easy grid fault detection method. A virtual damping resistance is used to drive the system to the resonance in order to extract the grid impedance parameters, both...... the power quality and even damage some sensitive loads connected at the point of the common coupling (PCC). This paper presents detection-estimation method of the grid impedance variation. This estimation tehnique aims to improve the dynamic of the distributed generation (DG) interfacing inverter control...

  12. Efficient Simultaneous Reconstruction of Time-Varying Images and Electrode Contact Impedances in Electrical Impedance Tomography.

    Science.gov (United States)

    Boverman, Gregory; Isaacson, David; Newell, Jonathan C; Saulnier, Gary J; Kao, Tzu-Jen; Amm, Bruce C; Wang, Xin; Davenport, David M; Chong, David H; Sahni, Rakesh; Ashe, Jeffrey M

    2017-04-01

    In electrical impedance tomography (EIT), we apply patterns of currents on a set of electrodes at the external boundary of an object, measure the resulting potentials at the electrodes, and, given the aggregate dataset, reconstruct the complex conductivity and permittivity within the object. It is possible to maximize sensitivity to internal conductivity changes by simultaneously applying currents and measuring potentials on all electrodes but this approach also maximizes sensitivity to changes in impedance at the interface. We have, therefore, developed algorithms to assess contact impedance changes at the interface as well as to efficiently and simultaneously reconstruct internal conductivity/permittivity changes within the body. We use simple linear algebraic manipulations, the generalized singular value decomposition, and a dual-mesh finite-element-based framework to reconstruct images in real time. We are also able to efficiently compute the linearized reconstruction for a wide range of regularization parameters and to compute both the generalized cross-validation parameter as well as the L-curve, objective approaches to determining the optimal regularization parameter, in a similarly efficient manner. Results are shown using data from a normal subject and from a clinical intensive care unit patient, both acquired with the GE GENESIS prototype EIT system, demonstrating significantly reduced boundary artifacts due to electrode drift and motion artifact.

  13. Novel 10-Bit Impedance-to-Digital Converter for Electrochemical Impedance Spectroscopy Measurements.

    Science.gov (United States)

    Chen, Tse-An; Wu, Wen-Jui; Wei, Chia-Ling; Darling, Robert B; Liu, Bin-Da

    2017-04-01

    Electrochemical impedance spectroscopy (EIS) is a widely used technique in biomedical and chemical analysis. A novel 10-bit impedance-to-digital converter (IDC), which can measure and directly convert the magnitude and phase of impedance to digital codes, is proposed for the EIS measurement system. The proposed IDC is composed of a magnitude-to-digital converter (MDC) and a phase-to-digital converter (PDC). The proposed IDC was designed and fabricated using a 0.35 [Formula: see text] 2P4M mixed-signal polycide process, and the core area is only 0.07 mm2. Moreover, it can work over a very wide frequency range (0.1 mHz-100 kHz), and has excellent accuracy. According to the measured results, the DNL of the MDC is within -0.3/+0.3 LSB, and the INL is around -3/+1 LSB. Moreover, an EIS measurement system, which is composed of the proposed IDC chip and some other commercial chips, is built to measure ZoBell's and melatonin solutions for validating the function of the proposed IDC.

  14. Electromechanical impedance-based fault detection in a rotating machine by using an operating condition compensation approach

    Science.gov (United States)

    Tsuruta, K. M.; Rabelo, D. S.; Guimarães, C. G.; Cavalini, A. A.; Finzi Neto, R. M.; Steffen, V.

    2017-04-01

    The electromechanical impedance is a condition-based maintenance (CBM) methodology that uses sensors network to evaluate health condition of mechanical systems. Piezoelectric transducers are used as sensors and actuators to damage detection. Such approach monitors changes in the electric impedance of piezoelectric transducers that are bonded to the host structure. Normally the evaluation of the impedance responses is performed by using damage metrics, which permit to quantify the influence of damage. This is possible since the sensor electrical impedance is directly related to the mechanical impedance of the structure. However, the frequency response functions (FRFs) resulting from this method are susceptible to environmental and operational conditions that must be accounted for in order to avoid false diagnostics. Thus, the aim of this paper relies on the correct detection of incipient faults in rotating shafts under operating condition by using a real-time Impedance-based Structural Health Monitoring (ISHM) method. For this purpose, a data normalization procedure for compensation of changes in environmental and operating conditions is used to minimize changes in impedance signatures resulting from these external influences. Changes on dynamic load result from altering the rotation speed and unbalance level, while temperature changes stem from daily room temperature variations. The compensation technique is based on a hybrid optimization method associated with a given damage metrics. Additionally, a statistical model is used for threshold determination based on the Statistical Process Control (SPC) method. Experimental results show that an incipient damage associated with temperature and dynamic loads effects could be successfully detected with a probability of detection above 95 % confidence for the majority of the sensors used.

  15. An Alternative to Impedance Screening: Unoccluded Frontal Bone Conduction Screening.

    Science.gov (United States)

    Square, Regina; And Others

    1985-01-01

    A bone conduction hearing screening test using frontal bone oscillator placement was compared with pure-tone air-conduction screening and impedance audiometry with 114 preschoolers. Unoccluded frontal bone conduction testing produced screening results not significantly different from results obtained by impedance audiometry. (CL)!

  16. Collective behavior of Dictyostelium discoideum monitored by impedance analysis

    Science.gov (United States)

    Schäfer, Edith; Aue, Dennis; Tarantola, Marco; Polo, Elena; Westendorf, Christian; Oikawa, Noriko; Bodenschatz, Eberhard; Geil, Burkhard; Janshoff, Andreas

    2013-01-01

    Dictyostelium discoideum cells respond to periodic signals of extracellular cAMP by collective changes of cell-cell and cell-substrate contacts. This was confirmed by dielectric analysis employing electric cell-substrate impedance sensing (ECIS) and impedance measurements involving cell-filled micro channels in conjunction with optical microscopy providing a comprehensive picture of chemotaxis under conditions of starvation. PMID:23713138

  17. Impedance study for the PEP-II B-factory

    Energy Technology Data Exchange (ETDEWEB)

    Heifets, S.; Daly, C.E.; Ko, K. [and others

    1995-06-01

    The paper summarizes results of the impedance studies of the components of the B-factory. The prime goal of this activity was to support the design of the vacuum chamber and, at the same time, to get a reasonable model of the machine impedance, which can be used later for detail studies of collective effects.

  18. Interpretation of the Gerischer impedance in solid state ionics

    NARCIS (Netherlands)

    Boukamp, Bernard A.; Bouwmeester, Henricus J.M.

    2003-01-01

    The Gerischer impedance in its most elementary form, ZG(ω)=Z0(k+jω)−1/2, has been observed in the frequency response of mixed conducting solid electrolyte systems. This simple transfer function can be derived directly from Fick's second law by including a reaction term. The Gerischer impedance was

  19. Application of dynamic impedance spectroscopy to atomic force microscopy

    Directory of Open Access Journals (Sweden)

    Kazimierz Darowicki, Artur Zieliński and Krzysztof J Kurzydłowski

    2008-01-01

    Full Text Available Atomic force microscopy (AFM is a universal imaging technique, while impedance spectroscopy is a fundamental method of determining the electrical properties of materials. It is useful to combine those techniques to obtain the spatial distribution of an impedance vector. This paper proposes a new combining approach utilizing multifrequency scanning and simultaneous AFM scanning of an investigated surface.

  20. AC impedance and dielectric spectroscopic studies of Mg ion ...

    Indian Academy of Sciences (India)

    Abstract. Polyvinyl alcohol (PVA)–polyethylene glycol (PEG) based solid polymer blend electrolytes with magne- sium nitrate have been prepared by the solution cast technique. Impedance spectroscopic technique has been used, to characterize these polymer electrolytes. Complex impedance analysis was used to ...

  1. Impedance Modeling of Solid Oxide Fuel Cell Cathodes

    DEFF Research Database (Denmark)

    Mortensen, Jakob Egeberg; Søgaard, Martin; Jacobsen, Torben

    2010-01-01

    A 1-dimensional impedance model for a solid oxide fuel cell cathode is formulated and applied to a cathode consisting of 50/50 wt% strontium doped lanthanum cobaltite and gadolinia doped ceria. A total of 42 impedance spectra were recorded in the temperature range: 555-852°C and in the oxygen...

  2. Electrical impedance measured changes in thoracic fluid content during thoracentesis

    DEFF Research Database (Denmark)

    Petersen, J R; Jensen, B V; Drabaek, H

    1994-01-01

    In patients (seven females and 11 males) with pleural effusion due to pulmonary (n = 13) or cardiac disease (n = 5) the change in baseline transthoracic impedance (Z0) was measured by electrical impedance (BoMed's NCCOM-3, 70 kHz) during thoracentesis. Data were obtained before and after withdrawal...

  3. AC impedance and dielectric spectroscopic studies of Mg 2 ion ...

    Indian Academy of Sciences (India)

    Polyvinyl alcohol (PVA)–polyethylene glycol (PEG) based solid polymer blend electrolytes with magnesium nitrate have been prepared by the solution cast technique. Impedance spectroscopic technique has been used, to characterize these polymer electrolytes. Complex impedance analysis was used to calculate bulk ...

  4. Impedance changes in chronically implanted and stimulated cochlear implant electrodes.

    Science.gov (United States)

    Newbold, Carrie; Mergen, Silvana; Richardson, Rachael; Seligman, Peter; Millard, Rodney; Cowan, Robert; Shepherd, Robert

    2014-07-01

    Electrode impedance increases following implantation and undergoes transitory reduction with onset of electrical stimulation. The studies in this paper measured the changes in access resistance and polarization impedance in vivo before and following electrical stimulation, and recorded the time course of these changes. Impedance measures recorded in (a) four cats following 6 months of cochlear implant use, and (b) three cochlear implant recipients with 1.5-5 years cochlear implant experience. Both the experimental and clinical data exhibited a reduction in electrode impedance, 20 and 5% respectively, within 15-30 minutes of stimulation onset. The majority of these changes occurred through reduction in polarization impedance. Cessation of stimulation was followed by an equivalent rise in impedance measures within 6-12 hours. Stimulus-induced reductions in impedance exhibit a rapid onset and are evident in both chronic in vivo models tested, even several years after implantation. Given the impedance changes were dominated by the polarization component, these findings suggest that the electrical stimulation altered the electrode surface rather than the bulk tissue and fluid in the cochlea.

  5. Large-scale ensemble averaging of ambulatory impedance cardiograms

    NARCIS (Netherlands)

    Riese, H; Groot, PFC; Van Den Berg, M; Kupper, NHM; Magnee, EHB; Rohaan, EJ; Vrijkotte, TGM; Willemsen, G; De Geus, EJC

    Impedance cardiography has been used increasingly to measure human physiological responses to emotional and mentally engaging stimuli. The validity of large-scale ensemble averaging of ambulatory impedance cardiograms was evaluated for preejection period (PEP), interbeat interval, and dZ/dt((min))

  6. Effect of Feeding and Suction on Gastric Impedance Spectroscopy Measurements.

    Science.gov (United States)

    Beltran, Nohra E; Sánchez-Miranda, Gustavo; Sacristan, Emilio

    2015-01-01

    A specific device and system has been developed and tested for clinical monitoring of gastric mucosal reactance in the critically ill as an early warning of splanchnic hypoperfusion associated with shock and sepsis. This device has been proven effective in clinical trials and is expected to become commercially available next year. The system uses a combination nasogastric tube and impedance spectroscopy probe as a single catheter. Because this device has a double function, the question is: Does enteral feeding or suction affect the gastric reactance measurements? This study was designed to evaluate the effect of feeding and suction on the measurement of gastric impedance spectroscopy in healthy volunteers. Impedance spectra were obtained from the gastric wall epithelia of 18 subjects. The spectra were measured for each of the following conditions: postinsertion of gastric probe, during active suction, postactive suction, and during enteral feeding (236 ml of nutritional supplement). Impedance spectra were reproducible in all volunteers under all conditions tested. There was a slight increase in impedance parameters after suction, and a decrease in impedance after feeding; however, these observed differences were insignificant compared to patient-to-patient variability, and truly negligible compared with previously observed changes associated with splanchnic ischemia in critically ill patients. Our results demonstrate that suction or feeding when using the impedance spectro-metry probe/nasogastric tube does not significantly interfere with gastric impedance spectrometer measurements.

  7. [A review of electrical impedance tomography based on MRI technique].

    Science.gov (United States)

    Yan, Dandan; Zhu, Shan'an; He, Bin

    2008-04-01

    In this paper, a review of a new electrical impedance tomography technique-magnetic resonance electrical impedance tomography (MREIT) is presented. Some medical imaging methods are briefly introduced. The basic theory of MREIT is given as well as its realization methods and developing status. The merits and challenges of this new trend are also demonstrated.

  8. Impedance Matching of Tapered Slot Antenna using a Dielectric Transformer

    Science.gov (United States)

    Simons, R. N.; Lee, R. Q.

    1998-01-01

    A new impedance matching technique for tapered slot antennas using a dielectric transformer is presented. The technique is demonstrated by measuring the input impedance, Voltage Standing Wave Ratio (VSWR) and the gain of a Vivaldi antenna (VA). Measured results at Ka-Band frequencies are presented and discussed.

  9. Beyond the networks

    DEFF Research Database (Denmark)

    Andreasen, Manja Hoppe; Møller-Jensen, Lasse

    2016-01-01

    through applications, co-financing of network extensions as well as lobbying efforts towards urban authorities and service providers. The formal service providers primarily take a reactive role, responding to demand, requests and political pressure from residents. Post-settlement network extensions...... are often complicated and impeded by costly and cumbersome land-acquisition processes, and because of the reactive and often piecemeal approach to network extensions, society may be missing out on potential benefits of scale. The way urban services work also means that the provision of services...

  10. Energy and water in the Great Lakes.

    Energy Technology Data Exchange (ETDEWEB)

    Tidwell, Vincent Carroll

    2011-11-01

    The nexus between thermoelectric power production and water use is not uniform across the U.S., but rather differs according to regional physiography, demography, power plant fleet composition, and the transmission network. That is, in some regions water demand for thermoelectric production is relatively small while in other regions it represents the dominate use. The later is the case for the Great Lakes region, which has important implications for the water resources and aquatic ecology of the Great Lakes watershed. This is today, but what about the future? Projected demographic trends, shifting lifestyles, and economic growth coupled with the threat of global climate change and mounting pressure for greater U.S. energy security could have profound effects on the region's energy future. Planning for such an uncertain future is further complicated by the fact that energy and environmental planning and regulatory decisionmaking is largely bifurcated in the region, with environmental and water resource concerns generally taken into account after new energy facilities and technologies have been proposed, or practices are already in place. Based on these confounding needs, the objective of this effort is to develop Great Lakes-specific methods and tools to integrate energy and water resource planning and thereby support the dual goals of smarter energy planning and development, and protection of Great Lakes water resources. Guiding policies for this planning are the Great Lakes and St. Lawrence River Basin Water Resources Compact and the Great Lakes Water Quality Agreement. The desired outcome of integrated energy-water-aquatic resource planning is a more sustainable regional energy mix for the Great Lakes basin ecosystem.

  11. Tuned driving of piezoelectric resonators: impedance matching

    Directory of Open Access Journals (Sweden)

    Pons, J. L.

    2006-06-01

    Full Text Available For optimal operation of piezoelectric resonators, the electrical impedance of electronic drivers and the resonator itself must be matched. Lack of matching results in a non smooth transmission of electrical power between the drive and the load which, in turn, leads to heating and poor efficiency. The rest of properties of the driving voltage (frequency, amplitude and phase are also affected by this mismatch. This paper presents the optimal design of power drivers for piezoelectric resonators. This approach is based on a first stage of electro-mechanical experimental characterization. This first step sets the basis for an impedance matching process. The approach has been experimentally validated on a well known piezoelectric resonator: the ultrasonic motor.

    La operación óptima de un resonador piezoeléctrico requiere de la adaptación de impedancia eléctrica entre el circuito de excitación y el propio resonador. La falta de adaptación se traduce en una pobre transmisión de potencia desde el excitador hasta el resonador, lo que a su vez se traduce en calentamiento y pérdida de eficienca en la operación. Las características morfológicas de la tensión de excitación (amplitud, frecuencia y fase también quedan afectadas por esta falta de adaptación. Este artículo analiza el diseño óptimo de la etapa de potencia de un circuito eléctrico de excitación para resonadores piezoeléctricos. Se trata la caracterización electromecánica del resonador y, en base a ésta, la adaptación de impedancias entre circuito y resonador. La contrastación experimental se ha llevado a cabo con un resonador bien estudiado en la literatura: un motor ultrasónico.

  12. Review: The Great Gatsby

    Directory of Open Access Journals (Sweden)

    Antonia de Jesus Sales

    2016-08-01

    Full Text Available A presente resenha busca discutir a tradução de The Great Gatsby para o contexto brasileiro. Diversas traduções foram feitas, em diversas épocas e com repercussão positiva no contexto brasileiro. Para o presente estudo, foi observada a tradução de Vanessa Bárbara, de 2011. Nesse sentido, o aspecto biográficos do autor e a forma como se apresentam os personagens na obra são fatores de cotejamento na obra original e na tradução brasileira. Francis Scott Key Fitzgerald (1896 – 1940 é famoso por ter em suas obras traços biográficos, algo que certamente influencia o leitor que adentra a sua obra. Quanto à recepção de O Grande Gatsby no contexto brasileiro, há que se considerar que O Grande Gatsby teve diversas traduções no Brasil. Depois dessa tradução de Vanessa Bárbara, em 2011, outras três vieram em 2013, juntamente com o filme. Há que considerar os aspectos comerciais embutidos nessas traduções e que muito corroboram para o resultado final. Prova disso são as capas, que são sempre diferenciadas em cada edição lançada. O tradutor nem sempre pode opinar sobre questões como estas. A tradução, a meu ver, é uma obra de qualidade, visto que a tradutora buscou ser fiel, sem dificultar a interpretação da obra para o leitor.

  13. Review: The Great Gatsby

    Directory of Open Access Journals (Sweden)

    Antonia de Jesus Sales

    2016-05-01

    Full Text Available A presente resenha busca discutir a tradução de The Great Gatsby para o contexto brasileiro. Diversas traduções foram feitas, em diversas épocas e com repercussão positiva no contexto brasileiro. Para o presente estudo, foi observada a tradução de Vanessa Bárbara, de 2011. Nesse sentido, o aspecto biográficos do autor e a forma como se apresentam os personagens na obra são fatores de cotejamento na obra original e na tradução brasileira. Francis Scott Key Fitzgerald (1896 – 1940 é famoso por ter em suas obras traços biográficos, algo que certamente influencia o leitor que adentra a sua obra. Quanto à recepção de O Grande Gatsby no contexto brasileiro, há que se considerar que O Grande Gatsby teve diversas traduções no Brasil. Depois dessa tradução de Vanessa Bárbara, em 2011, outras três vieram em 2013, juntamente com o filme. Há que considerar os aspectos comerciais embutidos nessas traduções e que muito corroboram para o resultado final. Prova disso são as capas, que são sempre diferenciadas em cada edição lançada. O tradutor nem sempre pode opinar sobre questões como estas. A tradução, a meu ver, é uma obra de qualidade, visto que a tradutora buscou ser fiel, sem dificultar a interpretação da obra para o leitor.

  14. Australia's Great Barrier Reef

    Science.gov (United States)

    2001-01-01

    The Great Barrier Reef extends for 2,000 kilometers along the northeastern coast of Australia. It is not a single reef, but a vast maze of reefs, passages, and coral cays (islands that are part of the reef). This nadir true-color image was acquired by the MISR instrument on August 26, 2000 (Terra orbit 3679), and shows part of the southern portion of the reef adjacent to the central Queensland coast. The width of the MISR swath is approximately 380 kilometers, with the reef clearly visible up to approximately 200 kilometers from the coast. It may be difficult to see the myriad details in the browse image, but if you retrieve the higher resolution version, a zoomed display reveals the spectacular structure of the many reefs.The more northerly coastal area in this image shows the vast extent of sugar cane cultivation, this being the largest sugar producing area in Australia, centered on the city of Mackay. Other industries in the area include coal, cattle, dairying, timber, grain, seafood, and fruit. The large island off the most northerly part of the coast visible in this image is Whitsunday Island, with smaller islands and reefs extending southeast, parallel to the coast. These include some of the better known resort islands such as Hayman, Lindeman, Hamilton, and Brampton Islands.Further south, just inland of the small semicircular bay near the right of the image, is Rockhampton, the largest city along the central Queensland coast, and the regional center for much of central Queensland. Rockhampton is just north of the Tropic of Capricorn. Its hinterland is a rich pastoral, agricultural, and mining region.MISR was built and is managed by NASA's Jet Propulsion Laboratory, Pasadena, CA, for NASA's Office of Earth Science, Washington, DC. The Terra satellite is managed by NASA's Goddard Space Flight Center, Greenbelt, MD. JPL is a division of the California Institute of Technology.

  15. Impedance Coordinative Control for Cascaded Converter in Bidirectional Application

    DEFF Research Database (Denmark)

    Tian, Yanjun; Deng, Fujin; Chen, Zhe

    2015-01-01

    Two stage cascaded converters are widely used in bidirectional applications, but the negative impedance may cause system instability. Actually the impedance interaction is much different between forward power flow and reversed power flow, which will introduce more uncertainty to the system...... stability. This paper proposes a control method for the constant power controlled converter in cascaded system, and consequently it can change the negative impedance of constant power converter into resistive impedance, which will improve the cascaded system stability, as well as merge the impedance...... difference between forward and reversed power flow. This paper addresses the analysis with the topology of cascaded dual-active-bridge converter (DAB) with inverter, and the proposed control method can also be implemented in unidirectional applications and other general cascaded converter system...

  16. Development of galvanostatic Fourier transform electrochemical impedance spectroscopy.

    Science.gov (United States)

    Nam, Kwang-Mo; Shin, Dong-Hyup; Jung, Namchul; Joo, Moon G; Jeon, Sangmin; Park, Su-Moon; Chang, Byoung-Yong

    2013-02-19

    Here, we report development of the galvanostatic Fourier transform electrochemical impedance spectroscopy (FTEIS), which monitors impedance of electrochemical reactions activated by current steps. We first derive relevant relations for potential change upon application of a step current, obtain impedances theoretically from the relations by simulation, and verify them with experimental results. The validity of the galvanostatic FTEIS technique is demonstrated by measuring impedances of a semiconductive silicon wafer using the conventional frequency response analysis (FRA), the potentiostatic FTEIS, and the galvanostatic FTEIS methods, and the results are in excellent agreement with each other. This work is significant in that the galvanostatic FTEIS would allow one to record impedance changes during charge/discharge cycles of secondary batteries and fuel cells as well as electrochemically irreversible systems which may produce noise level chronoamperometric currents by potentiostatic techniques.

  17. Microgrid Reactive and Harmonic Power Sharing Using Enhanced Virtual Impedance

    DEFF Research Database (Denmark)

    He, Jinwei; Wei Li, Yun; Guerrero, Josep M.

    2013-01-01

    only a line current feed-forward term is added to the DG voltage reference, the proposed virtual impedances at fundamental and harmonic frequencies are realized using DG line current and point of common coupling (PCC) voltage feed-forward terms, respectively. With this modification, the mismatched DG......To address the load sharing problem in islanding microgrids, this paper proposes an improved approach which regulates the distributed generation (DG) unit interfacing virtual impedance at fundamental and selected harmonic frequencies. In contrast to the conventional virtual impedance control where...... feeder impedances can be properly compensated, resulting in accurate reactive and harmonic power sharing at the same time. In addition, this paper shows that the microgrid PCC harmonic voltages can be mitigated by reducing the magnitude of DG unit equivalent harmonic impedance. Finally, an improved...

  18. Response of variable impedance stripline to pulse excitation

    Energy Technology Data Exchange (ETDEWEB)

    McWright, G.

    1984-12-15

    We describe a simple method to predict the transient response of variable impedance stripline to pulse excitation. The method uses a finite difference based, quasi-static impedance formulation to calculate the reflection coefficient at each point along the direction of pulse propagation and the subsequent short pulse behavior of a variable impedance structure. A Fortran computer program is written to determine the quasi-static impedance. Excellent agreement of better than 1% between the finite difference impedance predictions and experimental results is noted. A second computer program is written utilizing previous results but essentially incorporating reflection and transmission from several discontinuities to analyze the transient response of the structure. This transient analysis yields good agreement between predictions and results obtained by means of time domain reflectometry.

  19. Modeling the Impedance of Nanostructured PV in Simulink/matlab

    Science.gov (United States)

    Houshmand, Mohammad; Zandi, Mohammad. H.; Gorji, Nima E.

    2013-08-01

    Impedance measurement is a common method to study the electrical properties of thin film photovoltaics. For the first time, we use the MATLAB/Simulink environment to extract the complex impedance of the nanostructured heterojunction solar cells. The impedance magnitude, phase and Nyquist plot of the PV are simulated in LTI Viewer and Impedance versus Frequency analysis tools of SimPower GUI block of Simulink. We examined a variety of the equivalent circuits consisting of capacitance, series and shunt resistances representing the solar cell structure. The model uses the parameters with values reported in the literature at room temperature and zero bias. The effect of the additional capacitance and resistances in the equivalent circuits on the impedance components of the cells is considered by Simulink environment.

  20. Gastric Impedance Spectroscopy in Cardiovascular Surgery Patients vs. Healthy Volunteers.

    Science.gov (United States)

    Beltran, N; Sanchez-Miranda, G; Godinez, M; Diaz, U; Sacristan, E

    2005-01-01

    Impedance spectroscopy has been proposed as a method of monitoring mucosal injury due to hypoperfusion and ischemia in the critically ill. The present study evaluates spectral differences in elective cardiovascular surgery patients compared with the impedance spectra of the gastric mucosa in healthy adults. An impedance spectroscopy probe and nasogastric tube (ISP/NGT) was placed into the stomach of 77 heart surgery and 21 healthy volunteers. The recorded impedance spectra were classified into 3 groups: group 1 for healthy volunteers; group 2 for patients with neither ischemia nor complications; and group 3 for patients with ischemia and complications during the first 3 days in the recovery unit. There were statistical differences in resistance (p<0.001) and reactance (p<0.001) among the 3 groups. The results show that impedance spectra are distinct and significantly different in patients with probable ischemic mucosal injury compared to healthy subjects, and therefore this technology may be a useful prognostic and diagnostic monitoring tool.

  1. Great Lakes Environmental Database (GLENDA)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Great Lakes Environmental Database (GLENDA) houses environmental data on a wide variety of constituents in water, biota, sediment, and air in the Great Lakes area.

  2. Modifed Great Basin Extent (Buffered)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Two different great basin perimeter files were intersected and dissolved using ArcGIS 10.2.2 to create the outer perimeter of the great basin for use modeling...

  3. Great Lakes Initiative (GLI) Clearinghouse

    Science.gov (United States)

    The Great Lakes Initiative Toxicity Clearinghouse is a central location for information on criteria, toxicity data, exposure parameters and other supporting documents used in developing water quality standards in the Great Lakes watershed.

  4. Great Men and Us Too

    National Research Council Canada - National Science Library

    Mary Grayson

    2008-01-01

    .... These folks across the world stage as great heroes or great villains. The thoery is most often associated with Thomas Carlyle, a 19th century talk radio show host -- actually he was a Scottish historian -- known for his quote...

  5. Discerning apical and basolateral properties of HT-29/B6 and IPEC-J2 cell layers by impedance spectroscopy, mathematical modeling and machine learning.

    Directory of Open Access Journals (Sweden)

    Thomas Schmid

    Full Text Available Quantifying changes in partial resistances of epithelial barriers in vitro is a challenging and time-consuming task in physiology and pathophysiology. Here, we demonstrate that electrical properties of epithelial barriers can be estimated reliably by combining impedance spectroscopy measurements, mathematical modeling and machine learning algorithms. Conventional impedance spectroscopy is often used to estimate epithelial capacitance as well as epithelial and subepithelial resistance. Based on this, the more refined two-path impedance spectroscopy makes it possible to further distinguish transcellular and paracellular resistances. In a next step, transcellular properties may be further divided into their apical and basolateral components. The accuracy of these derived values, however, strongly depends on the accuracy of the initial estimates. To obtain adequate accuracy in estimating subepithelial and epithelial resistance, artificial neural networks were trained to estimate these parameters from model impedance spectra. Spectra that reflect behavior of either HT-29/B6 or IPEC-J2 cells as well as the data scatter intrinsic to the used experimental setup were created computationally. To prove the proposed approach, reliability of the estimations was assessed with both modeled and measured impedance spectra. Transcellular and paracellular resistances obtained by such neural network-enhanced two-path impedance spectroscopy are shown to be sufficiently reliable to derive the underlying apical and basolateral resistances and capacitances. As an exemplary perturbation of pathophysiological importance, the effect of forskolin on the apical resistance of HT-29/B6 cells was quantified.

  6. Pacemaker lead fracture without an increase in lead impedance caused by cardiac fibroma

    Directory of Open Access Journals (Sweden)

    Daisuke Sato

    2013-12-01

    Full Text Available We report the case of a 64-year-old man who had a permanent pacemaker with a unipolar silicone electrode positioned in the right ventricle in 1989 for sinus node dysfunction. On a routine checkup in June 2011, a 28-mm-diameter mass was discovered, which appeared to adhere to the tricuspid valve and the ventricular lead. The size of the mass did not change for the next 6 months, and the lead impedance was maintained at around 500–600 Ω. Because pacing failure was observed in January 2012, he underwent an urgent pacemaker check; however, the lead impedance was found not to have increased greatly (689 Ω. Nevertheless, the pacemaker lead was noted to be fractured at the tricuspid level. His echocardiogram showed new severe tricuspid regurgitation and a floating mass around the lead. We extracted the fractured lead, enucleated the tumor, replaced the tricuspid valve, and placed an epicardial lead. Macroscopic examination revealed that the tumor surrounded the fractured lead and covered the stump. Pathological examination revealed that the tumor was composed of fibrous connective tissue. We presumed that electric current continued to flow through the stump of the fractured unipolar lead to the generator, and this might have caused the limited increase in lead impedance.

  7. Journal and Wave Bearing Impedance Calculation Software

    Science.gov (United States)

    Hanford, Amanda; Campbell, Robert

    2012-01-01

    The wave bearing software suite is a MALTA application that computes bearing properties for user-specified wave bearing conditions, as well as plain journal bearings. Wave bearings are fluid film journal bearings with multi-lobed wave patterns around the circumference of the bearing surface. In this software suite, the dynamic coefficients are outputted in a way for easy implementation in a finite element model used in rotor dynamics analysis. The software has a graphical user interface (GUI) for inputting bearing geometry parameters, and uses MATLAB s structure interface for ease of interpreting data. This innovation was developed to provide the stiffness and damping components of wave bearing impedances. The computational method for computing bearing coefficients was originally designed for plain journal bearings and tilting pad bearings. Modifications to include a wave bearing profile consisted of changing the film thickness profile given by an equation, and writing an algorithm to locate the integration limits for each fluid region. Careful consideration was needed to implement the correct integration limits while computing the dynamic coefficients, depending on the form of the input/output variables specified in the algorithm.

  8. Electrochemical impedance spectroscopy of oxidized porous silicon

    Energy Technology Data Exchange (ETDEWEB)

    Mula, Guido, E-mail: guido.mula@unica.it [Dipartimento di Fisica, Università degli Studi di Cagliari, Cittadella Universitaria di Monserrato, S.P. 8 km 0.700, 09042 Cagliari (Italy); Tiddia, Maria V. [Dipartimento di Fisica, Università degli Studi di Cagliari, Cittadella Universitaria di Monserrato, S.P. 8 km 0.700, 09042 Cagliari (Italy); Ruffilli, Roberta [Nanochemistry, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genova (Italy); Falqui, Andrea [Nanochemistry, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genova (Italy); Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Cagliari, Cittadella Universitaria di Monserrato, S.P. 8 km 0.700, 09042 Cagliari (Italy); Palmas, Simonetta; Mascia, Michele [Dipartimento di Ingegneria Meccanica Chimica e dei Materiali, Università degli Studi di Cagliari, Piazza d' Armi, 09126 Cagliari (Italy)

    2014-04-01

    We present a study of the electrochemical oxidation process of porous silicon. We analyze the effect of the layer thickness (1.25–22 μm) and of the applied current density (1.1–11.1 mA/cm{sup 2}, values calculated with reference to the external samples surface) on the oxidation process by comparing the galvanostatic electrochemical impedance spectroscopy (EIS) measurements and the optical specular reflectivity of the samples. The results of EIS were interpreted using an equivalent circuit to separate the contribution of different sample parts. A different behavior of the electrochemical oxidation process has been found for thin and thick samples: whereas for thin samples the oxidation process is univocally related to current density and thickness, for thicker samples this is no more true. Measurements by Energy Dispersive Spectroscopy using a Scanning Electron Microscopy confirmed that the inhomogeneity of the electrochemical oxidation process is increased by higher thicknesses and higher currents. A possible explanation is proposed to justify the different behavior of thin and thick samples during the electrochemical process. - Highlights: • A multidisciplinary approach on porous Si electrochemical oxidation is proposed. • Electrochemical, optical, and structural characterizations are used. • Layer thickness and oxidation current effects are shown. • An explanation of the observed behavior is proposed.

  9. Electrical Impedance Tomography During Mechanical Ventilation.

    Science.gov (United States)

    Walsh, Brian K; Smallwood, Craig D

    2016-10-01

    Electrical impedance tomography (EIT) is a noninvasive, non-radiologic imaging modality that may be useful for the quantification of lung disorders and titration of mechanical ventilation. The principle of operation is based on changes in electrical conductivity that occur as a function of changes in lung volume during ventilation. EIT offers potentially important benefits over standard imaging modalities because the system is portable and non-radiologic and can be applied to patients for long periods of time. Rather than providing a technical dissection of the methods utilized to gather, compile, reconstruct, and display EIT images, the present article seeks to provide an overview of the clinical application of this technology as it relates to monitoring mechanical ventilation and providing decision support at the bedside. EIT has been shown to be useful in the detection of pneumothoraces, quantification of pulmonary edema and comparison of distribution of ventilation between different modes of ventilation and may offer superior individual titration of PEEP and other ventilator parameters compared with existing approaches. Although application of EIT is still primarily done within a research context, it may prove to be a useful bedside tool in the future. However, head-to-head comparisons with existing methods of mechanical ventilation titration in humans need to be conducted before its application in general ICUs can be recommended. Copyright © 2016 by Daedalus Enterprises.

  10. The Next Great Science

    Science.gov (United States)

    Hodges, K. V.

    2007-12-01

    value of systems-level thinking, and it makes good sense to make this the essential mantra of Earth science undergraduate and graduate programs of the future. We must emphasize that Earth science plays a central role in understanding processes that have shaped our planet since the origin of our species, processes that have thus influenced the rise and fall of human societies. By studying the co-evolution of Earth and human societies, we lay a critical part of the foundation for future environmental policymaking. If we can make this point persuasively, Earth science might just be the "next great science".

  11. Microfluidic Impedance Flow Cytometry Enabling High-Throughput Single-Cell Electrical Property Characterization

    OpenAIRE

    Jian Chen; Chengcheng Xue; Yang Zhao; Deyong Chen; Min-Hsien Wu; Junbo Wang

    2015-01-01

    This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1) early developments of microfluidic impedance flow cytometry for single-cell electrical property characterization; (2) microfluidic impedance flow cytometry with enhanced sensitivity; (3) microfluidic impedance ...

  12. Geometric Beam Coupling Impedance of LHC Secondary Collimators

    CERN Document Server

    Frasciello, O; Zobov, M; Grudiev, A; Mounet, N; Salvant, B

    2016-01-01

    The High Luminosity LHC project is aimed at increasing the LHC luminosity by an order of magnitude. One of the key ingredients to achieve the luminosity goal is the beam intensity increase. In order to keep under control beam instabilities and to avoid excessive power losses a careful design of new vacuum chamber components and an improvement of the present LHC impedance model are required. Collimators are the main impedance contributors. Measurements with beam have revealed that the betatron coherent tune shifts were by about a factor of 2 higher with respect to the theoretical predictions based on the current model. Up to now the resistive wall impedance has been considered as the major impedance contribution for collimators. By carefully simulating their geometric impedance we show that for the graphite collimators with half-gaps higher than 10 mm the geometric impedance exceeds the resistive wall one. In turn, for the tungsten collimators the geometric impedance dominates for all used gap values. Hence, i...

  13. Identification of Critical Transmission Limits in Injection Impedance Plane

    DEFF Research Database (Denmark)

    Jóhannsson, Hjörtur; Østergaard, Jacob; Nielsen, Arne Hejde

    2012-01-01

    In this paper, equations are derived that describe the mapping of critical boundaries and characteristic lines from the three dimensionalPQV-surface into the two-dimensional injection impedance plane (load impedance plane for both positive and negativeresistance). The expressions derived for the ......In this paper, equations are derived that describe the mapping of critical boundaries and characteristic lines from the three dimensionalPQV-surface into the two-dimensional injection impedance plane (load impedance plane for both positive and negativeresistance). The expressions derived...... for the critical and characteristic lines in the impedance plane form the basis for a new phasormeasurement based situational awareness method, which uses the results in this paper to identify critical operational boundariesin real time and to visualize the system operating conditions in an informative way....... The situational awareness method will bedescribed in a later paper, where this paper focuses on the derivations of some system characteristics in the injection (or load)impedance plane. The critical lines from the PQV-surface that are mapped into the impedance plane are the ones representing theconditions where...

  14. Characterizing aging effects of lithium ion batteries by impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Troeltzsch, Uwe [University of the Bundeswehr Munich Institute for Measurement and Automation, 85579 Neubiberg (Germany)]. E-mail: uwe.troeltzsch@unibw-muenchen.de; Kanoun, Olfa [University of the Bundeswehr Munich Institute for Measurement and Automation, 85579 Neubiberg (Germany); Traenkler, Hans-Rolf [University of the Bundeswehr Munich Institute for Measurement and Automation, 85579 Neubiberg (Germany)

    2006-01-20

    Impedance spectroscopy is one of the most promising methods for characterizing aging effects of portable secondary batteries online because it provides information about different aging mechanisms. However, application of impedance spectroscopy 'in the field' has some higher requirements than for laboratory experiments. It requires a fast impedance measurement process, an accurate model applicable with several batteries and a robust method for model parameter estimation. In this paper, we present a method measuring impedance at different frequencies simultaneously. We propose to use a composite electrode model, capable to describe porous composite electrode materials. A hybrid method for parameter estimation based on a combination of evolution strategy and Levenberg-Marquardt method allowed a robust and fast parameter calculation. Based on this approach, an experimental investigation of aging effects of a lithium ion battery was carried out. After 230 discharge/charge cycles, the battery showed a 14% decreased capacity. Modeling results show that series resistance, charge transfer resistance and Warburg coefficient changed thereby their values by approximately 60%. A single frequency impedance measurement, usually carried out at 1 kHz, delivers only information about series resistance. Impedance spectroscopy allows additionally the estimation of charge transfer resistance and Warburg coefficient. This fact and the high sensitivity of model parameters to capacity change prove that impedance spectroscopy together with an accurate modeling deliver information that significantly improve characterization of aging effects.

  15. Characteristic impedance: frequency or time domain approach?

    Science.gov (United States)

    Qureshi, Muhammad Umar; Colebank, Mitchel; Schreier, David; Tabima Martinez, Diana Marcela; Haider, Mansoor A; Chesler, Naomi C; Olufsen, Mette S

    2017-11-27

    Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of Zc can be obtained using methods based on frequency or time domain analysis. Applications of these methods under different physiological and pathological conditions in species with different body sizes and heart rates show that the two approaches do not always yield the same result. Considering the interpretation and role of Zc as an important hemodynamic parameter, we have investigated the discrepancies between frequency and time domain estimates accounting for uncertainties associated with experimental processes and physiological conditions. We have used published data measured in different species including humans, dogs and mice, to investigate: (a) the effects of time delay and signal noise in the pressure-flow data, (b) uncertainties about the blood flow conditions, (c) and the periodicity of the cardiac cycle versus breathing cycle, on the frequency and time domain estimates of Zc, and (d) if discrepancies observed under different hemodynamic conditions can be eliminated. We have shown that the frequency and time domain estimates are not equally sensitive to certain characteristics of hemodynamic signals including phase lag between pressure and flow, signal to noise ratio and the end of systole retrograde flow. The discrepancies between two types of estimates are inherent due to their intrinsically different mathematical expressions and therefore it is impossible to define a criterion to resolve such discrepancies. We propose that the frequency and time domain estimates of Zc should be further assessed as two different hemodynamic parameters in a future study. © 2017 Institute of Physics and Engineering in Medicine.

  16. Electrochemical Characterization of a PEMEC Using Impedance Spectroscopy

    DEFF Research Database (Denmark)

    Elsøe, Katrine; Grahl-Madsen, L.; Scherer, G.G.

    2017-01-01

    In this study, electrochemical impedance spectroscopy (EIS) is applied in combination with cyclic voltammetry (CV) and current density – cell voltage curves (iV-curves) to investigate the processes contributing to the total impedance of a polymer electrolyte membrane electrolysis cell (PEMEC). i......V-curves were linear above 0.35 A cm−2 implying ohmic processes to be performance limiting, however the impedance spectra showed three arcs indicating three electrochemical reactions at these conditions not to be purely ohmic, but also to have capacitive properties. A hypothesis that the composite Ir...

  17. Acoustic impedances of audiometric earphones coupled to different loads

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2005-01-01

    , audiometric earphones are coupled to different loads. Thus, they are placed on different terminations of the tube including metal plate, artificial rubber pinna and upper part of the standardized coupler. The results show that the impedances of earphones are different, but they also differ from radiation...... impedances of used terminations (seen from inside the tube without earphone). In addition, there is an indication of differences among the earphones regarding the influence of the load on their impedances. These results are going to be further analysed together with the corresponding ones obtained...

  18. A novel evaporation detection system using an impedance sensing chip.

    Science.gov (United States)

    Lin, Yung-Sheng; Chen, Cheng-You

    2014-11-21

    This paper presents a novel real-time impedance sensing chip for the evaporation detection of small volume solutions. Time sharing detection is performed for multiple sample measurements by a relay switching technique. In contrast to a conventional weight loss approach, the advantage of this proposed impedance sensing system is that it not only merely requires as little as 0.5 mL of test samples, but also provides high sensitivity and fast detection. More importantly, this proposed impedance sensing chip has advantages of a small chip size and easy decomposition for cleaning and reuse.

  19. Reliability of impedance cardiography in measuring central haemodynamics

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Stadeager, C

    1991-01-01

    The purpose of the study described here was to investigate the reliability of impedance cardiography (IC) in measuring cardiac output (CO) and central blood volume. Absolute values and changes in these variables obtained by impedance cardiography and by isotope- or thermodilution techniques were...... compared. The reproducibility of IC within the same day was compared with that of isotope dilution and the reproducibility in IC from day to day was derived. Finally, the effects of the readings of impedance tracings by different observers were quantified. The results are based on 270 measurements in 37...

  20. How the Inductive Voltage Adder (IVA) output impedance affects impedance dynamics of a Self-Magnetic Pinch (SMP) diode

    Science.gov (United States)

    Renk, Timothy; Simpson, Sean; Webb, Timothy; Mazarakis, Michael; Kiefer, Mark

    2016-10-01

    The SMP diode, fielded on the RITS-6 (3.5-8.5 MV) IVA accelerator at Sandia National Laboratories, produces a focused electron beam (transmission line (MITL) center conductors, of 40 and 80 ohms flow impedance. We have operated in-situ heating and discharge-cleaning hardware in the load region, in order to address the tendency of some shots to undergo premature impedance (Z) collapse, defined as a fall in impedance beyond that due to normal movement of electrode plasmas that reduces the effective A-K gap. The goal of heating/cleaning was to reduce the volume of evolving gases near the A-K gap. Despite clear evidence that the cleaning techniques removed the proton portion of beam current, we observed no consistent increase in diode impedance (ZDIODE). This forced an examination of the role that the IVA flow impedance has on ZDIODE. A preliminary conclusion is that ZDIODE should be at least 1.5 times the flow impedance before ZDIODE is a parameter independent of flow impedance. This has implications for SMP as a load for a IVA, since ZDIODE >100 ohms has not been consistently demonstrated. Data analysis is ongoing, and latest results will be reported. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  1. Novel Family of Single-Phase Modified Impedance-Source Buck-Boost Multilevel Inverters with Reduced Switch Count

    DEFF Research Database (Denmark)

    Husev, Oleksandr; Strzelecki, Ryszard; Blaabjerg, Frede

    2016-01-01

    This paper describes novel single-phase solutions with increased inverter voltage levels derived by means of a nonstandard inverter configuration and impedance source networks. Operation principles based on special modulation techniques are presented. Detailed component design guidelines along wi...... with simulation and experimental verification are also provided. Possible application fields are discussed, as well as advantages and disadvantages. Finally, future studies are addressed for the new solutions....

  2. Great Barrier Reef, Queensland, Australia

    Science.gov (United States)

    1990-01-01

    This detailed view of the Great Barrier Reef, Queensland, Australia (19.5S, 149.5E) shows several small patch reefs within the overall reef system. The Great Barrier Reef, largest in the world, comprises thousands of individual reefs of great variety and are closely monitored by marine ecologists. These reefs are about 6000 years old and sit on top of much older reefs. The most rapid coral growth occurs on the landward side of the reefs.

  3. Managing Networks

    DEFF Research Database (Denmark)

    Jørgensen, Heidi; Vintergaard, Christian

    Logically it seems that companies pursuing different business strategies wouldalso manage their relationships with other firms accordingly. Nevertheless, due tothe lack of research in the field of network strategies, this link still remainsinadequately examined. Based on the well-known framework...... isprovided, that the relation between a company's strategy, structure and processesin fact have a considerable influence on its pattern of network behaviour. Threecase studies from the Danish biotech industry exemplify and illustrate how acompany's strategy is directly correlated with how it manages its...... of organisationalbehaviour developed by Miles and Snow (1978), this paper argues that thepatterns of network behaviour practiced by firms greatly depend on the businesstypology of the company. That is, a company's business typology will to a certaindegree dictate the network identity of the company. In this paper evidence...

  4. Analytical model of impedance in elliptical beam pipes

    CERN Document Server

    Pesah, Arthur Chalom

    2017-01-01

    Beam instabilities are among the main limitations in building higher intensity accelerators. Having a good impedance model for every accelerators is necessary in order to build components that minimize the probability of instabilities caused by the interaction beam-environment and to understand what piece to change in case of intensity increasing. Most of accelerator components have their impedance simulated with finite elements method (using softwares like CST Studio), but simple components such as circular or flat pipes are modeled analytically, with a decreasing computation time and an increasing precision compared to their simulated model. Elliptical beam pipes, while being a simple component present in some accelerators, still misses a good analytical model working for the hole range of velocities and frequencies. In this report, we present a general framework to study the impedance of elliptical pipes analytically. We developed a model for both longitudinal and transverse impedance, first in the case of...

  5. Statistical Properties of Antenna Impedance in an Electrically Large Cavity

    Energy Technology Data Exchange (ETDEWEB)

    WARNE,LARRY K.; LEE,KELVIN S.H.; HUDSON,H. GERALD; JOHNSON,WILLIAM A.; JORGENSON,ROY E.; STRONACH,STEPHEN L.

    2000-12-13

    This paper presents models and measurements of antenna input impedance in resonant cavities at high frequencies.The behavior of input impedance is useful in determining the transmission and reception characteristics of an antenna (as well as the transmission characteristics of certain apertures). Results are presented for both the case where the cavity is undermoded (modes with separate and discrete spectra) as well as the over moded case (modes with overlapping spectra). A modal series is constructed and analyzed to determine the impedance statistical distribution. Both electrically small as well as electrically longer resonant and wall mounted antennas are analyzed. Measurements in a large mode stirred chamber cavity are compared with calculations. Finally a method based on power arguments is given, yielding simple formulas for the impedance distribution.

  6. Low profile conformal antenna arrays on high impedance substrate

    CERN Document Server

    Singh, Hema; Jha, Rakesh Mohan

    2016-01-01

    This book presents electromagnetic (EM) design and analysis of dipole antenna array over high impedance substrate (HIS). HIS is a preferred substrate for low-profile antenna design, owing to its unique boundary conditions. Such substrates permit radiating elements to be printed on them without any disturbance in the radiation characteristics. Moreover HIS provides improved impedance matching, enhanced bandwidth, and increased broadside directivity owing to total reflection from the reactive surface and high input impedance. This book considers different configurations of HIS for array design on planar and non-planar high-impedance surfaces. Results are presented for cylindrical dipole, printed dipole, and folded dipole over single- and double-layered square-patch-based HIS and dogbone-based HIS. The performance of antenna arrays is analyzed in terms of performance parameters such as return loss and radiation pattern. The design presented shows acceptable return loss and mainlobe gain of radiation pattern. Thi...

  7. Refined impedance boundary conditions on a semitransparent periodically loaded structure

    Science.gov (United States)

    Tereshin, O. N.; Dvurechenskii, V. D.

    1987-09-01

    Improved impedance boundary conditions are presented for a semitransparent periodically loaded structure, i.e., a periodic array of conductors in which reactive loads are inserted. Structures of this sort find application in antenna-feed devices.

  8. Bioelectrical impedance analysis for bovine milk: Preliminary results

    Science.gov (United States)

    Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.

    2010-04-01

    This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.

  9. Interdigitated electrodes as impedance and capacitance biosensors: A review

    Science.gov (United States)

    Mazlan, N. S.; Ramli, M. M.; Abdullah, M. M. A. B.; Halin, D. S. C.; Isa, S. S. M.; Talip, L. F. A.; Danial, N. S.; Murad, S. A. Z.

    2017-09-01

    Interdigitated electrodes (IDEs) are made of two individually addressable interdigitated comb-like electrode structures. IDEs are one of the most favored transducers, widely utilized in technological applications especially in the field of biological and chemical sensors due to their inexpensive, ease of fabrication process and high sensitivity. In order to detect and analyze a biochemical molecule or analyte, the impedance and capacitance signal need to be obtained. This paper investigates the working principle and influencer of the impedance and capacitance biosensors. The impedance biosensor depends on the resistance and capacitance while the capacitance biosensor influenced by the dielectric permittivity. However, the geometry and structures of the interdigitated electrodes affect both impedance and capacitance biosensor. The details have been discussed in this paper.

  10. Lower leg electrical impedance after distal bypass surgery

    DEFF Research Database (Denmark)

    Belanger, G K; Bolbjerg, M L; Heegaard, N H

    1998-01-01

    Electrical impedance was determined in 13 patients following distal bypass surgery to evaluate lower leg oedema as reflected by its circumference. Tissue injury was assessed by the plasma concentration of muscle enzymes. After surgery, the volume of the control lower leg increased from 1250 (816......-104) ohms (P surgery was indicated by an increase in total creatine kinase (n = 17) and MB isoenzyme of creatine kinase (n = 8) (P surgery (P ... of troponin I (n = 8). In conclusion, tissue injury was reflected by increases in muscle enzymes in plasma. We found an inverse correlation between lower leg electrical impedance and volume, but the deviation in electrical impedance was approximately twice that of the leg volume. Electrical impedance appears...

  11. Bioelectrical impedance analysis for an endangered desert fish—Data

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — These data were used to examine the effectiveness of a non-lethal tool (Bioelectrical Impedance Analysis, "BIA") to estimate the physiological condition of...

  12. Fuel Cell Impedance Model Parameters Optimization using a Genetic Algorithm

    National Research Council Canada - National Science Library

    Mohamed Selmene Ben Yahia; Hatem Allagui; Arafet Bouaicha; Abdelkader Mami

    2017-01-01

    .... The method used for the identification is a sample genetic algorithm and the proposed impedance model is based on electric parameters, which will be found from a sweeping of well determined frequency bands...

  13. Measurement of hand volume by bioelectrical impedance spectroscopy.

    Science.gov (United States)

    Ward, L C; Dylke, E S; Kilbreath, S L

    2012-06-01

    Assessment of lymphedema is frequently based upon measuring the increase in volume of the affected region compared to that of a comparable unaffected region. This requires methods that can measure the volume of body regions that are not only accurate and sensitive but also suitable for use in clinical practice. To date, bioimpedance spectroscopy has been used to measure volume increase due to lymphedema in whole arms but excluding the hand. We report here an impedance-based method for the measurement of hand volume. Impedance measurement electrodes were located on the dorsum of the hand, with the sense electrodes at the level of ulnar styloid and metacarpal-phalangeal joint of the third finger and current drive electrodes on the forearm and at the nail bed of the third finger. The impedances of the hands of 50 participants were measured and hand volumes computed. These were compared with the hand volumes measured by perometry. The region of the hand defined by the impedance measurements was determined, both in vivo and using a hand phantom. The region of the hand measured by the impedance technique was limited to the palmar volume (i.e., excluding the thumb). Palmar volumes computed from impedance measurements were significantly correlated (r=0.88) with those measured by perometry but were, on average, 8% larger. The impedance technique was sufficiently sensitive to detect the change in hand volume elicited by decrease in vascular volume due to blood draining from the hand on elevation. An impedance technique was developed that has the potential to measure the change in hand volume when affected by lymphedema. Bioimpedance spectroscopy has the advantage over currently used perometric or water displacement techniques in that it can measure specifically the change in extracellular fluid, including lymph, rather than simply total hand volume.

  14. Development of Longitudinal Coupling Impedance Measurement Platform for BEPCII

    CERN Document Server

    Huang, Gang; Wang Jiu Qing; Zheng, Shuxin; Zhou, Demin

    2005-01-01

    A coaxial line impedance measurement platform is developed for BEPCII. A pair of gradual change impedance matching section is designed and fabricated by numerical control milling machine. The special designed RF connector is applied to strengthen the inner conductor. The algorithm of TRL calibration is applied in the system to avoid the usage of a reference pipe for each device under test. The measurement is accomplished by a VNA under the control of the software written in LabView.

  15. Retrieving complex surface impedances from statistical absorption coefficients

    DEFF Research Database (Denmark)

    Mondet, Boris Jean-Francois; Brunskog, Jonas; Jeong, Cheol-Ho

    2017-01-01

    In room acoustic simulations the surface materials are commonly represented with energy parameters, such as the absorption and scattering coefficients, which do not carry phase information. This paper presents a method to transform statistical absorption coefficients into complex surface impedances...... coefficients, prior information about the absorber of interest can be used as constraints, which is shown to help determine the correct impedance from absorption coefficient. Further stability and sensitivity investigations indicate that the method presented constitutes an efficient solution to convert sound...

  16. MD 349: Impedance Localization with AC-dipole

    CERN Document Server

    Biancacci, Nicolo; Metral, Elias; Salvant, Benoit; Papotti, Giulia; Persson, Tobias Hakan Bjorn; Tomas Garcia, Rogelio; CERN. Geneva. ATS Department

    2016-01-01

    The purpose of this MD is to measure the distribution of the transverse impedance of the LHC by observing the phase advance variation with intensity between the machine BPMs. Four injected bunches with different intensities are excited with an AC dipole and the turn by turn data is acquired from the BPM system. Through post-processing analysis the phase variation along the machine is depicted and, from this information, first conclusions of the impedance distribution can be drawn.

  17. Scattering of wedges and cones with impedance boundary conditions

    CERN Document Server

    Lyalinov, Mikhail

    2012-01-01

    This book is a systematic and detailed exposition of different analytical techniques used in studying two of the canonical problems, the wave scattering by wedges or cones with impedance boundary conditions. It is the first reference on novel, highly efficient analytical-numerical approaches for wave diffraction by impedance wedges or cones. The applicability of the reported solution procedures and formulae to existing software packages designed for real-world high-frequency problems encountered in antenna, wave propagation, and radar cross section.

  18. Development of a Multifidelity Approach to Acoustic Liner Impedance Eduction

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.

    2017-01-01

    The use of acoustic liners has proven to be extremely effective in reducing aircraft engine fan noise transmission/radiation. However, the introduction of advanced fan designs and shorter engine nacelles has highlighted a need for novel acoustic liner designs that provide increased fan noise reduction over a broader frequency range. To achieve aggressive noise reduction goals, advanced broadband liner designs, such as zone liners and variable impedance liners, will likely depart from conventional uniform impedance configurations. Therefore, educing the impedance of these axial- and/or spanwise-variable impedance liners will require models that account for three-dimensional effects, thereby increasing computational expense. Thus, it would seem advantageous to investigate the use of multifidelity modeling approaches to impedance eduction for these advanced designs. This paper describes an extension of the use of the CDUCT-LaRC code to acoustic liner impedance eduction. The proposed approach is applied to a hardwall insert and conventional liner using simulated data. Educed values compare well with those educed using two extensively tested and validated approaches. The results are very promising and provide justification to further pursue the complementary use of CDUCT-LaRC with the currently used finite element codes to increase the efficiency of the eduction process for configurations involving three-dimensional effects.

  19. Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis

    Science.gov (United States)

    Weyer, Sören; Pauly, Karolin; Napp, Andreas; Dreher, Michael; Leonhardt, Steffen; Marx, Nikolaus; Schauerte, Patrick; Mischke, Karl

    2015-01-01

    Background. Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. Methods. 45 participants (21 with pleural effusion and 24 healthy subjects) were included. Bioelectrical impedance was analyzed for “Transthoracic,” “Foot to Foot,” “Foot to Hand,” and “Hand to Hand” vectors in low and high frequency domain before and after thoracentesis. Healthy subjects were measured at a single time point. Results. The mean volume of removed pleural effusion was 1169 ± 513 mL. The “Foot to Foot,” “Hand to Hand,” and “Foot to Hand” vector indicated a trend for increased bioelectrical impedance after thoracentesis. Values for the low frequency domain in the “Transthoracic” vector increased significantly (P < 0.001). A moderate correlation was observed between the amount of removed fluid and impedance change in the low frequency domain using the “Foot to Hand” vector (r = −0.7). Conclusion. Bioelectrical impedance changes in correlation with the thoracic fluid level. It was feasible to monitor significant fluid shifts and loss after thoracentesis in the “Transthoracic” vector by means of bioelectrical impedance spectroscopy. The trial is registered with Registration Numbers IRB EK206/11 and NCT01778270. PMID:25861647

  20. Transverse impedance of a periodic array of cavities

    Directory of Open Access Journals (Sweden)

    A. V. Fedotov

    1999-06-01

    Full Text Available We examine the transverse impedance of a periodic array of cavities in a beam pipe at high frequency. The calculation is an extension of a previous one for the longitudinal impedance of a periodic array of azimuthally symmetric pillboxes, for which only TM modes were needed. In the present case, we must include TE modes as well. In addition, we extend the applicability of the previous calculation by including an extra term in the coupling kernel so that the results are valid for all values of the ratio of the cavity length to the period of the structure (all values of the ratio of iris thickness to structure period. In spite of the presence of TE modes, we find that the high frequency limit of the transverse impedance is simply (2/ka^{2} times the corresponding limit of the longitudinal impedance, just as it is for the resistive wall impedances, a relation which occurs frequently for azimuthally symmetric structures. Finally, we present numerical results as well as approximate expressions for the impedance per period, valid for all ratios of cavity length to structure period.

  1. Entrance and Exit CSR Impedance for Non-Ultrarelativistic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Li, Rui; Tsai, Cheng Ying [SLAC National Accelerator Lab., Menlo Park, CA (United States); Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States)

    2017-05-01

    For a high-brightness electron beam being transported through beamlines involving bending systems, the coherent synchrotron radiation (CSR) and longitudinal space charge (LSC) interaction could often cause microbunching instability. The semi-analytical Vlasov solver for microbunching gain* depends on the impedances for the relevant collective effects. The existing results for CSR impedances are usually obtained for the ultrarelativistic limit. To extend the microbunching analysis to cases of low energies, such as the case of an ERL merger, or to density modulations at extremely small wavelength, it is necessary to extend the impedance analysis to the non-ultrarelativistic regime. In this study, we present the impedance analysis for the transient CSR interaction in the non-ultrarelativistic regime, for transients including both entrance to and exit from a magnetic dipole. These impedance results will be compared to their ultra-relativistic counterparts**, and the corresponding wakefield obtained from the impedance for low-energy beams will be compared with the existing results of transient CSR wakefield for general beam energies***.

  2. Impedance Control for Robotic Rehabilitation: A Robust Markovian Approach

    Directory of Open Access Journals (Sweden)

    Andres L. Jutinico

    2017-08-01

    Full Text Available The human-robot interaction has played an important role in rehabilitation robotics and impedance control has been used in the regulation of interaction forces between the robot actuator and human limbs. Series elastic actuators (SEAs have been an efficient solution in the design of this kind of robotic application. Standard implementations of impedance control with SEAs require an internal force control loop for guaranteeing the desired impedance output. However, nonlinearities and uncertainties hamper such a guarantee of an accurate force level in this human-robot interaction. This paper addresses the dependence of the impedance control performance on the force control and proposes a control approach that improves the force control robustness. A unified model of the human-robot system that considers the ankle impedance by a second-order dynamics subject to uncertainties in the stiffness, damping, and inertia parameters has been developed. Fixed, resistive, and passive operation modes of the robotics system were defined, where transition probabilities among the modes were modeled through a Markov chain. A robust regulator for Markovian jump linear systems was used in the design of the force control. Experimental results show the approach improves the impedance control performance. For comparison purposes, a standard H∞ force controller based on the fixed operation mode has also been designed. The Markovian control approach outperformed the H∞ control when all operation modes were taken into account.

  3. Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis

    Directory of Open Access Journals (Sweden)

    Matthias Daniel Zink

    2015-01-01

    Full Text Available Background. Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. Methods. 45 participants (21 with pleural effusion and 24 healthy subjects were included. Bioelectrical impedance was analyzed for “Transthoracic,” “Foot to Foot,” “Foot to Hand,” and “Hand to Hand” vectors in low and high frequency domain before and after thoracentesis. Healthy subjects were measured at a single time point. Results. The mean volume of removed pleural effusion was 1169±513 mL. The “Foot to Foot,” “Hand to Hand,” and “Foot to Hand” vector indicated a trend for increased bioelectrical impedance after thoracentesis. Values for the low frequency domain in the “Transthoracic” vector increased significantly (P<0.001. A moderate correlation was observed between the amount of removed fluid and impedance change in the low frequency domain using the “Foot to Hand” vector (r=-0.7. Conclusion. Bioelectrical impedance changes in correlation with the thoracic fluid level. It was feasible to monitor significant fluid shifts and loss after thoracentesis in the “Transthoracic” vector by means of bioelectrical impedance spectroscopy. The trial is registered with Registration Numbers IRB EK206/11 and NCT01778270.

  4. Michigan: The Great Lakes State

    Science.gov (United States)

    McKay, Sandra Lee; La Luzerne-Oi, Sally

    2009-01-01

    Although Michigan is often called the "Wolverine State," its more common nickname is the "Great Lakes State." This name comes from the fact that Michigan is the only state in the United States that borders four of the five Great Lakes. Also referred to as the "Water Wonderland," Michigan has 11,000 additional lakes,…

  5. What Caused the Great Depression?

    Science.gov (United States)

    Caldwell, Jean; O'Driscoll, Timothy G.

    2007-01-01

    Economists and historians have struggled for almost 80 years to account for the American Great Depression, which began in 1929 and lasted until the early years of World War II. In this article, the authors discuss three major schools of thought on the causes of the Great Depression and the long failure of the American economy to return to full…

  6. How users experience great products

    NARCIS (Netherlands)

    Ortiz Nicolas, J.C.; Aurisicchio, M.; Desmet, P.M.A.

    2013-01-01

    This study reports qualitative research about how users experience great products. Eighteen interviews were conducted in which participants were asked to bring along a ‘great’ product that they own. During the interviews participants explained why they consider a product great and how they

  7. Analysis and design of triple-band high-impedance surface absorber with periodic diversified impedance

    Science.gov (United States)

    Rui Zhang, Guo; Heng Zhou, Pei; Bin Zhang, Hui; Bo Zhang, Lin; Liang Xie, Jian; Jiang Deng, Long

    2013-10-01

    In this paper, a triple-band planar absorber with high-impedance surface (HIS) is designed and fabricated. The absorber structure is composed of polyurethane foam sandwiched between a lossy sheet of frequency selective surfaces (FSS) and a perfect electric conductor. The lossy FSS possesses different resistances in a periodic composite unit as compared with typical HIS absorber. Losses in the FSS are introduced by printing the periodic composite square ring pattern on blank stickers using various resistive inks. Physical mechanism of the HIS absorbers is analyzed by equivalent circuit model and electric field distribution studies. The proposed absorber with periodic composite units offers superimposed triple-band absorption as compared with that of the single units having single- or dual-band absorption characteristics. The reflection loss measurements show that the 90% absorption bandwidth of the HIS absorber is increased by 42% by the proposed composite periodic units.

  8. Stochastic Gabor reflectivity and acoustic impedance inversion

    Science.gov (United States)

    Hariri Naghadeh, Diako; Morley, Christopher Keith; Ferguson, Angus John

    2018-02-01

    To delineate subsurface lithology to estimate petrophysical properties of a reservoir, it is possible to use acoustic impedance (AI) which is the result of seismic inversion. To change amplitude to AI, removal of wavelet effects from the seismic signal in order to get a reflection series, and subsequently transforming those reflections to AI, is vital. To carry out seismic inversion correctly it is important to not assume that the seismic signal is stationary. However, all stationary deconvolution methods are designed following that assumption. To increase temporal resolution and interpretation ability, amplitude compensation and phase correction are inevitable. Those are pitfalls of stationary reflectivity inversion. Although stationary reflectivity inversion methods are trying to estimate reflectivity series, because of incorrect assumptions their estimations will not be correct, but may be useful. Trying to convert those reflection series to AI, also merging with the low frequency initial model, can help us. The aim of this study was to apply non-stationary deconvolution to eliminate time variant wavelet effects from the signal and to convert the estimated reflection series to the absolute AI by getting bias from well logs. To carry out this aim, stochastic Gabor inversion in the time domain was used. The Gabor transform derived the signal’s time–frequency analysis and estimated wavelet properties from different windows. Dealing with different time windows gave an ability to create a time-variant kernel matrix, which was used to remove matrix effects from seismic data. The result was a reflection series that does not follow the stationary assumption. The subsequent step was to convert those reflections to AI using well information. Synthetic and real data sets were used to show the ability of the introduced method. The results highlight that the time cost to get seismic inversion is negligible related to general Gabor inversion in the frequency domain. Also

  9. System-on-Chip Integration of a New Electromechanical Impedance Calculation Method for Aircraft Structure Health Monitoring

    Directory of Open Access Journals (Sweden)

    Daniel Medale

    2012-10-01

    Full Text Available The work reported on this paper describes a new methodology implementation for active structural health monitoring of recent aircraft parts made from carbon-fiber-reinforced polymer. This diagnosis is based on a new embedded method that is capable of measuring the local high frequency impedance spectrum of the structure through the calculation of the electro-mechanical impedance of a piezoelectric patch pasted non-permanently onto its surface. This paper involves both the laboratory based E/M impedance method development, its implementation into a CPU with limited resources as well as a comparison with experimental testing data needed to demonstrate the feasibility of flaw detection on composite materials and answer the question of the method reliability. The different development steps are presented and the integration issues are discussed. Furthermore, we present the unique advantages that the reconfigurable electronics through System-on-Chip (SoC technology brings to the system scaling and flexibility. At the end of this article, we demonstrate the capability of a basic network of sensors mounted onto a real composite aircraft part specimen to capture its local impedance spectrum signature and to diagnosis different delamination sizes using a comparison with a baseline.

  10. Optimizing utilization efficiencies in electronegative discharges: The importance of the impedance phase angle

    Science.gov (United States)

    Entley, W. R.; Langan, J. G.; Felker, B. S.; Sobolewski, M. A.

    1999-11-01

    We have investigated the operating conditions that result in the greatest utilization efficiencies (UEs) of NF3, CF4, and C2F6 in a capacitively coupled GEC reference cell. We have also independently measured the rf electrical characteristics and optical emission spectra of the plasmas. To avoid inadvertently attributing changes in the UE, discharge impedance, rf currents, or atomic emission intensities to parasitic losses in the matching network or rf delivery system, the rf generator was adjusted to ensure that the same amount of power was dissipated within each discharge. For the NF3 plasmas, argon was used as a diluent and both the NF3 concentration and reactor pressure were varied. For the CF4 and C2F6 based plasmas, the gas compositions were fixed (86 mol % CF4/O2 and 50 mol % C2F6/O2) and the reactor pressure was varied. The greatest NF3 UEs occurred within a narrow range of NF3 partial pressures. The greatest CF4 and C2F6 UEs occurred within a narrow range of reactor pressures. For all mixtures, operating conditions that yielded the highest UEs also yielded the brightest plasmas, the lowest impedance magnitudes, the greatest fraction of current flowing to the grounded electrode, and impedance phase angles within a narrow window centered near φpe=-40°. Within this region, plasma power is most efficiently utilized to dissociate the source gas and excite the atoms that emit light. Collapsed plasmas, observed for high pressure highly electronegative conditions, exhibited very low UEs. At optimal operating conditions the UE of the fluorinated source gases were found to decrease in the order: NF3>C2F6>CF4. The results of this study suggest that the baseline corrected fluorine atom emission intensity (703.7 nm), the magnitude of the discharge impedance, or phase angle of the discharge impedance could be monitored to determine the relative fluorinated source gas UE in an arbitrary plasma reactor as the operating conditions are varied. The concept of an ideal NF3

  11. Design of matching networks for low noise preamplifiers.

    Science.gov (United States)

    Reykowski, A; Wright, S M; Porter, J R

    1995-06-01

    This paper discusses matching networks that minimize inductive coupling between the antennas within an array while simultaneously insuring minimum noise contributions from preamplifiers. Typical low noise preamplifier designs require a strong mismatch between the source impedance and the amplifier input impedance (reflection coefficient close to one) to achieve optimal noise performance. This is in contrast to the familiar impedance match known from communication theory where input and source impedances have complex conjugate values for maximizing the power transfer from source to amplifier. The high input reflection coefficient of low noise amplifiers can be exploited to reduce antenna currents by using lossless impedance transformations to create a high impedance at the coil terminals while simultaneously maintaining a low noise figure for the amplifier. The networks presented here constitute an improvement over previous work because they give additional freedoms regarding the values of the network components and the amplifier input impedance. The technique has been formalized and coded in MathCad, making the design of realizable networks a simple process.

  12. Compassion makes good care great.

    Science.gov (United States)

    Carlisle, Daloni

    2014-05-27

    Daloni Carlisle reveals how the compassionate nursing care she received in a London hospital following a recent cancer diagnosis has given her an 'emotional understanding of what constitutes great nursing care.

  13. Great Lakes Initiative (GLI) Clearinghouse

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Great Lakes Initiative Toxicity Data Clearinghouse is a central location for information on criteria, toxicity data, exposure parameters and other supporting...

  14. Multiple Refuge Bat Inventory: Great Basin & Great Northern LCC

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This was a cooperative project between the Upper Columbia Basin Network (UCBN) of the National Park Service I&M Program, USFWS Region 1 I&M Program (R1...

  15. The Sixth Great Mass Extinction

    Science.gov (United States)

    Wagler, Ron

    2012-01-01

    Five past great mass extinctions have occurred during Earth's history. Humanity is currently in the midst of a sixth, human-induced great mass extinction of plant and animal life (e.g., Alroy 2008; Jackson 2008; Lewis 2006; McDaniel and Borton 2002; Rockstrom et al. 2009; Rohr et al. 2008; Steffen, Crutzen, and McNeill 2007; Thomas et al. 2004;…

  16. Impedance dispersion analysis of drug-membrane interactions

    Science.gov (United States)

    Tacheva, Bilyana; Paarvanova, Boyana; Ivanov, Ivan T.; Karabaliev, Miroslav

    2017-11-01

    Thin lipid films modified glassy carbon electrodes (GCE) were used in this work as model system for studying the interactions between two antipsychotic phenothiazine drugs, chlorpromazine and thioridazine, and the lipid fraction of the biomembranes. The lipid films on the electrode surface were obtained through the thinning of film-forming lipid solution deposited between an electrolyte phase and the working GC electrode. The effects of the drugs on the lipid film structure were investigated by electrochemical impedance spectroscopy (EIS). To characterize the electric properties of the lipid film the impedance of the working GCE is modeled with an equivalent circuit consisting of parallel capacitance Cp and resistance Rp. These capacitance and resistance are not frequency independent but could be calculated as equivalent Cp and Rp for each measured frequency of the impedance spectrum and presented as functions of the frequency f, Cp = Cp(f) and Rp= Rp(f). For the lipid films used in this work, it is demonstrated that both Cp(f) and Rp(f) are well approximated with power-law functions. This behavior implies that the impedance Z of the films could be analysed in terms of the well-known constant-phase angle element (CPE), which is often used to describe the interfacial impedance of solid working electrodes.

  17. Impedance cardiography – optimization and efficacy evaluation of antihypertensive treatment

    Directory of Open Access Journals (Sweden)

    Katarzyna Panasiuk-Kamińska

    2016-09-01

    Full Text Available Background . Hypertension is a civilization disease which currently affects about 10.5 m people in Poland. The number of patients with diagnosed, untreated hypertension amounts to 18%, and as many as 45% of patients are treated ineffectively whereas only 26% are treated effectively. Impedance cardiography (IC is an important tool both in diagnostics and the treatment of hypertensive patients, particularly in the case of antihypertensive treatment resistance. This method allows for the individualized treatment of each patient on the basis of hemodynamic parameters, monitoring of hypertensive patients in the outpatient care setting, and the assessment of cardiovascular risk factors. Objectives . The aim of the study was to evaluate the efficacy of hypotensive medications in patients with hypertension using impedance cardiography. Material and methods. The study involved 60 hypertensive patients, treated with antihypertensives, who failed to achieve the required blood pressure values. The modification of hypertension therapy was based on EBM (evidence-based medicine and on hemodynamic parameters obtained using impedance cardiography. Results . It was found that high blood pressure therapy based on impedance cardiography parameters has a significant influence on blood pressure reduction compared to EM B-based therapy: below 140/90: 66.8 vs. 55.1% and below 130/80: 23.5 vs. 18.9%. Conclusions . On the basis of this study it was confirmed that impedance cardiography allows for a significant reduction of hypertension and the selection of the most effective therapeutic strategy, providing for the optimization and efficacy of hypertension treatment.

  18. Utilization of bone impedance for age estimation in postmortem cases.

    Science.gov (United States)

    Ishikawa, Noboru; Suganami, Hideki; Nishida, Atsushi; Miyamori, Daisuke; Kakiuchi, Yasuhiro; Yamada, Naotake; Wook-Cheol, Kim; Kubo, Toshikazu; Ikegaya, Hiroshi

    2015-11-01

    In the field of Forensic Medicine the number of unidentified cadavers has increased due to natural disasters and international terrorism. The age estimation is very important for identification of the victims. The degree of sagittal closure is one of such age estimation methods. However it is not widely accepted as a reliable method for age estimation. In this study, we have examined whether measuring impedance value (z-values) of the sagittal suture of the skull is related to the age in men and women and discussed the possibility to use bone impedance for age estimation. Bone impedance values increased with aging and decreased after the age of 64.5. Then we compared age estimation through the conventional visual method and the proposed bone impedance measurement technique. It is suggested that the bone impedance measuring technique may be of value to forensic science as a method of age estimation. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  19. Development of a wearable multi-frequency impedance cardiography device.

    Science.gov (United States)

    Weyer, Sören; Menden, Tobias; Leicht, Lennart; Leonhardt, Steffen; Wartzek, Tobias

    2015-02-01

    Cardiovascular diseases as well as pulmonary oedema can be early diagnosed using vital signs and thoracic bio-impedance. By recording the electrocardiogram (ECG) and the impedance cardiogram (ICG), vital parameters are captured continuously. The aim of this study is the continuous monitoring of ECG and multi-frequency ICG by a mobile system. A mobile measuring system, based on 'low-power' ECG, ICG and an included radio transmission is described. Due to the high component integration, a board size of only 6.5 cm×5 cm could be realized. The measured data can be transmitted via Bluetooth and visualized on a portable monitor. By using energy-efficient hardware, the system can operate for up to 18 hs with a 3 V battery, continuously sending data via Bluetooth. Longer operating times can be realized by decreased transfer rates. The relative error of the impedance measurement was less than 1%. The ECG and ICG measurements allow an approximate calculation of the heart stroke volume. The ECG and the measured impedance showed a high correlation to commercial devices (r=0.83, p<0.05). In addition to commercial devices, the developed system allows a multi-frequency measurement of the thoracic impedance between 5-150 kHz.

  20. Gastric impedance spectroscopy in elective cardiovascular surgery patients.

    Science.gov (United States)

    Beltran, N E; Sanchez-Miranda, G; Godinez, M; Diaz, U; Sacristan, E

    2006-03-01

    Impedance spectroscopy has been proposed as a method of monitoring mucosal injury due to hypoperfusion and ischemia in critically ill patients. The present study characterizes human gastric impedance spectral changes under gastric hypoperfusion in patients undergoing cardiovascular surgery, and evaluates spectral differences between patients with no evidence of gastric ischemia and complications, and patients who developed ischemia and complications. Cole and Kun parameters were calculated over time to characterize changes as tissue injury progresses. Gastric ischemia was determined by air tonometry. Impedance spectroscopy spectra were obtained from 63 cardiovascular surgery patients. The recorded spectra were classified into three groups: group 1 for patients without ischemia or complications, group 2 for patients with a short period of ischemia (less than 2 h) and group 3 for patients with more than 4 h of gastric ischemia and complications. Two distinct dispersion regions of the spectra centered at about 316 Hz and 215 kHz become clearer as tissue damage develops. The average spectrum in group 3 shows a significant difference in tissue impedance at all frequencies relative to group 1. The parameters obtained for human gastric tissue show significant changes that occur at different times and at different frequencies as ischemia progresses, and could be correlated with patient outcome. This confirms our hypothesis that hypoperfusion and ischemia cause evident changes in the impedance spectra of the gastric wall. Therefore, this technology may be a useful prognostic and diagnostic monitoring tool.

  1. Mathematical models for predicting human mobility in the context of infectious disease spread: introducing the impedance model

    Directory of Open Access Journals (Sweden)

    Kankoé Sallah

    2017-11-01

    Full Text Available Abstract Background Mathematical models of human mobility have demonstrated a great potential for infectious disease epidemiology in contexts of data scarcity. While the commonly used gravity model involves parameter tuning and is thus difficult to implement without reference data, the more recent radiation model based on population densities is parameter-free, but biased. In this study we introduce the new impedance model, by analogy with electricity. Previous research has compared models on the basis of a few specific available spatial patterns. In this study, we use a systematic simulation-based approach to assess the performances. Methods Five hundred spatial patterns were generated using various area sizes and location coordinates. Model performances were evaluated based on these patterns. For simulated data, comparison measures were average root mean square error (aRMSE and bias criteria. Modeling of the 2010 Haiti cholera epidemic with a basic susceptible–infected–recovered (SIR framework allowed an empirical evaluation through assessing the goodness-of-fit of the observed epidemic curve. Results The new, parameter-free impedance model outperformed previous models on simulated data according to average aRMSE and bias criteria. The impedance model achieved better performances with heterogeneous population densities and small destination populations. As a proof of concept, the basic compartmental SIR framework was used to confirm the results obtained with the impedance model in predicting the spread of cholera in Haiti in 2010. Conclusions The proposed new impedance model provides accurate estimations of human mobility, especially when the population distribution is highly heterogeneous. This model can therefore help to achieve more accurate predictions of disease spread in the context of an epidemic.

  2. Mathematical models for predicting human mobility in the context of infectious disease spread: introducing the impedance model.

    Science.gov (United States)

    Sallah, Kankoé; Giorgi, Roch; Bengtsson, Linus; Lu, Xin; Wetter, Erik; Adrien, Paul; Rebaudet, Stanislas; Piarroux, Renaud; Gaudart, Jean

    2017-11-22

    Mathematical models of human mobility have demonstrated a great potential for infectious disease epidemiology in contexts of data scarcity. While the commonly used gravity model involves parameter tuning and is thus difficult to implement without reference data, the more recent radiation model based on population densities is parameter-free, but biased. In this study we introduce the new impedance model, by analogy with electricity. Previous research has compared models on the basis of a few specific available spatial patterns. In this study, we use a systematic simulation-based approach to assess the performances. Five hundred spatial patterns were generated using various area sizes and location coordinates. Model performances were evaluated based on these patterns. For simulated data, comparison measures were average root mean square error (aRMSE) and bias criteria. Modeling of the 2010 Haiti cholera epidemic with a basic susceptible-infected-recovered (SIR) framework allowed an empirical evaluation through assessing the goodness-of-fit of the observed epidemic curve. The new, parameter-free impedance model outperformed previous models on simulated data according to average aRMSE and bias criteria. The impedance model achieved better performances with heterogeneous population densities and small destination populations. As a proof of concept, the basic compartmental SIR framework was used to confirm the results obtained with the impedance model in predicting the spread of cholera in Haiti in 2010. The proposed new impedance model provides accurate estimations of human mobility, especially when the population distribution is highly heterogeneous. This model can therefore help to achieve more accurate predictions of disease spread in the context of an epidemic.

  3. The application of impedance measurement to assess biofilm development on technical materials used for water supply system construction

    Directory of Open Access Journals (Sweden)

    Wolf Mirela

    2017-01-01

    Full Text Available The lack of biological stability of water which is introduced into the network, leads primarily to its secondary contamination during transport to the consumer. The water that is biologically unstable creates ideal conditions for colonization of the inner surface of pipelines by microorganisms and adhesion of their products (biocorrosion. The studies was conducted using the identified microorganisms isolated from the water supply network which accounted inocula in continuous culture of biofilm in CDC reactor. As a result of studies it was revealed the presence of biofilm formed on different materials polyethylene, polypropylene, polyvinyl chloride, polybutylene. Microbiological biodiversity of organisms inhabiting a biofilm of the diversity of nucleic acids was used. It was observed the amount of the psychrophilic bacteria oscillation in the effluent from the reactor. It was also determined the affinity of various bacteria to the plastic through adhesion measurement using impedance spectroscopy. For impedance measurements apparatus SIGNAL RECOVERY 7280 DSP LOCK-IN AMPLIFIER was used, recording impedance components (real and imaginary. The results will allow for the creation of biosensor systems that can be used in predicting health risks in connection with drinking water and taking corrective actions.

  4. The application of impedance measurement to assess biofilm development on technical materials used for water supply system construction

    Science.gov (United States)

    Wolf, Mirela; Traczewska, Teodora; Grzebyk, Tomasz

    2017-11-01

    The lack of biological stability of water which is introduced into the network, leads primarily to its secondary contamination during transport to the consumer. The water that is biologically unstable creates ideal conditions for colonization of the inner surface of pipelines by microorganisms and adhesion of their products (biocorrosion). The studies was conducted using the identified microorganisms isolated from the water supply network which accounted inocula in continuous culture of biofilm in CDC reactor. As a result of studies it was revealed the presence of biofilm formed on different materials polyethylene, polypropylene, polyvinyl chloride, polybutylene. Microbiological biodiversity of organisms inhabiting a biofilm of the diversity of nucleic acids was used. It was observed the amount of the psychrophilic bacteria oscillation in the effluent from the reactor. It was also determined the affinity of various bacteria to the plastic through adhesion measurement using impedance spectroscopy. For impedance measurements apparatus SIGNAL RECOVERY 7280 DSP LOCK-IN AMPLIFIER was used, recording impedance components (real and imaginary). The results will allow for the creation of biosensor systems that can be used in predicting health risks in connection with drinking water and taking corrective actions.

  5. Use of impedance ratios to assess hand swelling in lymphoedema.

    Science.gov (United States)

    Dylke, E S; Alsobayel, H; Ward, L C; Liu, M; Webb, E; Kilbreath, S L

    2014-03-01

    To determine whether bioimpedance spectroscopy was suitable for detection of hand lymphoedema. The hands of 50 participants without a history of lymphoedema were measured with perometry and bioimpedance spectroscopy after positioning two ways for three minutes: (a) both hands rested at heart height and (b) the dominant hand at heart height and the non-dominant hand at head height. In addition, 10 women with secondary hand lymphoedema were also measured. Impedance and volume measurements were found to be strongly related (dominant hand r = -0.794). Both measurements were reliable (ICC2,1 = 0.900-0.967 and 0.988-0.996, respectively). Impedance was more sensitive to small changes in hand volume due to the postural change (position × device interaction: F = 23.9, P < 0.001). Finally, impedance measurements had better discrimination of women with lymphoedema than volume measurements. Bioimpedance spectroscopy is a promising tool for the detection of secondary hand lymphoedema.

  6. Electrochemical Impedance Modeling of a Solid Oxide Fuel Cell Anode

    DEFF Research Database (Denmark)

    Mohammadi, R.; Søgaard, Martin; Ramos, Tania

    2014-01-01

    (TLM), which is suitably modified to account for the electrode microstructural details, is used for modeling the impedance arising from the electrochemical reactions. In order to solve the system of nonlinear equations, an in-house code based on the finite difference method was developed. Some......A simulation package for the impedance response of SOFC anodes is presented here. The model couples the gas transport in gas channels and within a porous electrode with the electrochemical kinetics. The gas phase mass transport is modeled using mass conservation equations. A transmission line model...... of the model constants have been calibrated against experimental data. It is demonstrated that the simulation tool is capable of predicting the impedance response of an experimental data set obtained on symmetrical cells with Ni/ScYSZ SOFC anodes. A parametric study is also carried out using the developed...

  7. Low-frequency quadrupole impedance of undulators and wigglers

    Directory of Open Access Journals (Sweden)

    A. Blednykh

    2016-10-01

    Full Text Available An analytical expression of the low-frequency quadrupole impedance for undulators and wigglers is derived and benchmarked against beam-based impedance measurements done at the 3 GeV NSLS-II storage ring. The adopted theoretical model, valid for an arbitrary number of electromagnetic layers with parallel geometry, allows to calculate the quadrupole impedance for arbitrary values of the magnetic permeability μ_{r}. In the comparison of the analytical results with the measurements for variable magnet gaps, two limit cases of the permeability have been studied: the case of perfect magnets (μ_{r}→∞, and the case in which the magnets are fully saturated (μ_{r}=1.

  8. Energy storage cell impedance measuring apparatus, methods and related systems

    Science.gov (United States)

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.

    2017-12-26

    Energy storage cell impedance testing devices, circuits, and related methods are disclosed. An energy storage cell impedance measuring device includes a sum of sinusoids (SOS) current excitation circuit including differential current sources configured to isolate a ground terminal of the differential current sources from a positive terminal and a negative terminal of an energy storage cell. A method includes applying an SOS signal comprising a sum of sinusoidal current signals to the energy storage cell with the SOS current excitation circuit, each of the sinusoidal current signals oscillating at a different one of a plurality of different frequencies. The method also includes measuring an electrical signal at a positive terminal and a negative terminal of the energy storage cell, and computing an impedance of the energy storage cell at each of the plurality of different frequencies using the measured electrical signal.

  9. Grid impedance detection via excitation of LCL-filter resonance

    DEFF Research Database (Denmark)

    Liserre, Marco; Blaabjerg, Frede; Teodorescu, Remus

    2005-01-01

    Inverters adopted in distributed power generation, active filter and UPS are often connected to the grid through an LCL-fiIter. The impedance of the LCL-fiIter has a typical frequency spectrum with a resonance peak. Hence the LCL-fiIter has to be damped in order to avoid instability. However...... will address some possible limits, some solutions and some implementation issues (e.g. how to obtain a controlled resonance in the filter without damaging the system) in order to use the resonant peak for grid impedance detection. The analysis is validated both by simulations and experimental results....... the resonance of the LCL-fiIter can be also excited in a controlled way in order to individuate the resonance frequency in the spectrum (using for example the FFn. This paper proposes to use a controlled excitation to measure the grid impedance, since this one influences also the resonance frequency. This paper...

  10. Impedance-based structural health monitoring (Conference Presentation)

    Science.gov (United States)

    Park, Gyuhae; Inman, Daniel J.

    2017-04-01

    This paper presents an overview of impedance-based structural health monitoring, which has been pioneered by Inman and his research group. The basic principle behind this technique is to apply high frequency structural excitations (typically greater than 30 kHz) through the surface-bonded piezoelectric transducers, and measure the impedance of structures by monitoring the current and voltage applied to the piezoelectric transducers. Changes in impedance indicate changes in the structure, which in turn can indicate that damage has occurred. For the last two decades, extensive research works have been performed to various applications, including mechanical, aerospace and civil structural components. The technique has been also extended to piezoelectric sensor diagnostics, concrete cure monitoring, and biomedical applications. This paper presents the summary of how this technique has been evolved with the significant contribution by Inman.

  11. Fractional diffusion equation and impedance spectroscopy of electrolytic cells.

    Science.gov (United States)

    Lenzi, E K; Evangelista, L R; Barbero, G

    2009-08-20

    The influence of the ions on the electrochemical impedance of a cell is calculated in the framework of a complete model in which the fractional drift-diffusion problem is analytically solved. The resulting distribution of the electric field inside the sample is determined by solving Poisson's equation. The theoretical model to determine the electrical impedance we are proposing here is based on the fractional derivative of distributed order on the diffusion equation. We argue that this is the more convenient and physically significant approach to account for the enormous variety of the diffusive regimes in a real cell. The frequency dependence of the real and imaginary parts of the impedance are shown to be very similar to the ones experimentally obtained in a large variety of electrolytic samples.

  12. Road Impedance Model Study under the Control of Intersection Signal

    Directory of Open Access Journals (Sweden)

    Yunlin Luo

    2015-01-01

    Full Text Available Road traffic impedance model is a difficult and critical point in urban traffic assignment and route guidance. The paper takes a signalized intersection as the research object. On the basis of traditional traffic wave theory including the implementation of traffic wave model and the analysis of vehicles’ gathering and dissipating, the road traffic impedance model is researched by determining the basic travel time and waiting delay time. Numerical example results have proved that the proposed model in this paper has received better calculation performance compared to existing model, especially in flat hours. The values of mean absolute percentage error (MAPE and mean absolute deviation (MAD are separately reduced by 3.78% and 2.62 s. It shows that the proposed model has feasibility and availability in road traffic impedance under intersection signal.

  13. Complex Impedance Spectroscopic Properties of BaVO Ceramics

    Directory of Open Access Journals (Sweden)

    Praveen Khatri

    2008-01-01

    Full Text Available The polycrystalline sample of Ba3V2O8 was prepared by a high-temperature solid-state reaction technique. The effect of temperature on impedance parameters was studied using an impedance analyzer in a wide frequency range (102-106 Hz. The real and imaginary parts of complex impedance trace semicircles in the complex plane. The temperature-dependent plots reveal the presence of both bulk and grain boundary effects above 125∘C. The bulk resistance of the material decreases with rise in temperature. This exhibits a typical negative temperature coefficient of resistance (NTCR behavior of the material. The modulus analysis suggests a possible hopping mechanism for electrical transport processes of the material. The nature of variation of dc conductivity suggests the Arrhenius type of electrical conductivity.

  14. Mutual impedance of parallel and perpendicular coplanar surface monopoles

    Science.gov (United States)

    Koksal, Adnan; Kauffman, J. F.

    1991-01-01

    One dimensional integral formulas are derived for mutual impedance of arbitrary size, coplanar, parallel, and perpendicular surface monopoles. The integrals in formulas are expressed as exponential integrals where possible. The mutual impedance expression for parallel monopoles is a summation of exponential integrals and one-dimensional integrals. For perpendicular monopoles, the mutual impedance is in closed form, containing exponential integrals only. The final expressions are in a form suitable for numerical computation. Since the expressions contain at most one-dimensional integrals, they can be utilized to reduce the matrix filling time in the moment method formulations, especially when inhomogeneous sectioning is preferred. Additionally, they can be used in rectangular surface patch modeling of conducting surfaces with edges which are at an angle to the surface patches, providing the angle is small. To this end, the expressions were utilized in the moment method analysis of linearly tapered slot antennas. Very good accuracy was obtained with a reduction in computer time.

  15. Effect of the Tem Mode on the kicker Impedance

    CERN Document Server

    Zannini, C; Vaccaro, VG

    2012-01-01

    The kickers are major contributors to the CERN SPS beam coupling impedance. As such, they may represent a limitation to increasing the SPS bunch current in the frame of a luminosity upgrade of the LHC. The C-Magnet supports a transverse electromagnetic (TEM) mode due to the presence of two conductors. Due to the finite length of the structure this TEM mode affects the impedance below a certain frequency (when the penetration depth in the ferrite becomes comparable to the magnetic circuit length). A theoretical model was developed to take into account also the impedance contribution due to the TEM mode. The model is found to be in good agreement with CST 3D electromagnetic (EM) simulations. It allows for generic terminations in the longitudinal direction. An example of kicker is analyzed taking into account also the external cables.

  16. Electrical impedance tomography of the 1995 OGI gasoline release

    Energy Technology Data Exchange (ETDEWEB)

    Daily, W.; Ramirez, A.

    1996-10-01

    Electrical impedance tomography (EIT) was used to image the plume resulting from a release of 378 liters (100 gallons) of gasoline into a sandy acquifer. Images were made in 5 planes before and 5 times during the release, to generate a detailed picture of the spatial as well as the temporal development of the plume as it spread at the water table. Information of the electrical impedance (both in phase and out of phase voltages) was used or several different frequencies to produce images. We observed little dispersion in the images either before or after the gasoline entered the acquifer. Likewise, despite some laboratory measurements of impedances, there was no evidence of a change in the reactance in the soil because of the gasoline.

  17. Diffusion and conversion impedance in solid oxide fuel cells

    DEFF Research Database (Denmark)

    Jacobsen, Torben; Hendriksen, Peter Vang; Koch, Søren

    2008-01-01

    In fuel cell electrodes where the thin, active electrode layer is supported by a porous layer the diffusion processes as well as the change in the gas phase composition due to the conversion of reactants will influence the cell impedance. Two models are developed for the description...... to consumption of reactants and accumulation of products. For simplicity this model is restricted to cases dominated by mass transfer and conversion of the gas supply. Qualitatively the predictions by both models are alike. At high frequencies a Warburg diffusion impedance is seen. Depending on the dimensions...... of the gas volume relative to the supporting layer this may turn towards the real axis as a nernstian diffusion impedance, or directly into the semicircle dominating the low frequency region....

  18. Gas breakdown and plasma impedance in split-ring resonators

    Science.gov (United States)

    Hoskinson, Alan R.; Parsons, Stephen; Hopwood, Jeffrey

    2016-02-01

    The appearance of resonant structures in metamaterials coupled to plasmas motivates the systematic investigation of gas breakdown and plasma impedance in split-ring resonators over a frequency range of 0.5-9 GHz. In co-planar electrode gaps of 100 μm, the breakdown voltage amplitude decreases from 280 V to 225 V over this frequency range in atmospheric argon. At the highest frequency, a microplasma can be sustained using only 2 mW of power. At 20 mW, we measure a central electron density of 2 × 1020 m-3. The plasma-electrode overlap plays a key role in the microplasma impedance and causes the sheath impedance to dominate the plasma resistance at very low power levels. Contribution to the Topical Issue "Recent Breakthroughs in Microplasma Science and Technology", edited by Kurt Becker, Jose Lopez, David Staack, Klaus-Dieter Weltmann and Wei Dong Zhu.

  19. Ground Loop Impedance of Long EHV Cable Lines

    DEFF Research Database (Denmark)

    Ohno, Teruo; Bak, Claus Leth; Sørensen, Thomas K.

    2012-01-01

    The distance protection scheme without communication is often applied to the backup protection of EHV cable lines. For a reliable operation of a ground distance relay, the ground loop impedance of EHV cable lines needs to have a linear relationship to the distance from the relay location...... to the fault location. The discontinuity of the ground loop impedance at cross-bonding points may have an ill effect on the reliable operation of the ground distance relay. However, the cause and parameters of the discontinuity and its effects on the ground distance relay protection have not been discussed...... in literature. Through the calculation of the ground loop impedance for cable lines, it has been found that, for long EHV cable lines, the reliable operation of the ground distance relay is possible with a typical relay setting. Effects of parameters, such as substation grounding, cable layouts...

  20. Using the Web To Explore the Great Depression.

    Science.gov (United States)

    Chamberlin, Paul

    2001-01-01

    Presents an annotated list of Web sites that focus on the Great Depression. Includes the American Experience, American Memory, the National Archives and Records Administration, and the New Deal Network Web sites. Offers additional sites covering topics such as the Jersey homesteads and labor history. (CMK)

  1. Signal Processing for the Impedance Measurement on an Electrochemical Generator

    Directory of Open Access Journals (Sweden)

    El-Hassane AGLZIM

    2008-04-01

    Full Text Available Improving the life time of batteries or fuel cells requires the optimization of components such as membranes and electrodes and enhancement of the flow of gases [1], [2]. These goals could be reached by using a real time measurement on loaded generator. The impedance spectroscopy is a new way that was recently investigated. In this paper, we present an electronic measurement instrumentation developed in our laboratory to measure and plot the impedance of a loaded electrochemical generator like batteries and fuel cells. Impedance measures were done according to variations of the frequency in a larger band than what is usually used. The electronic instrumentation is controlled by Hpvee® software which allows us to plot the Nyquist graph of the electrochemical generator impedance. The theoretical results obtained in simulation under Pspice® confirm the choice of the method and its advantage. For safety reasons, the experimental preliminary tests were done on a 12 V vehicle battery, having an input current of 330 A and a capacity of 40 Ah and are now extended to a fuel cell. The results were plotted at various nominal voltages of the battery (12.7 V, 10 V, 8 V and 5 V and with two imposed currents (0.6 A and 4 A. The Nyquist diagram resulting from the experimental data enable us to show an influence of the load of the battery on its internal impedance. The similitude in the graph form and in order of magnitude of the values obtained (both theoretical and practical enables us to validate our electronic measurement instrumentation. Different sensors (temperature, pressure were placed around the device under test (DUT. These influence parameters were permanently recorded. Results presented here concern a classic loaded 12 V vehicle battery. The Nyquist diagram resulting from the experimental data confirms the influence of the load of the DUT on its internal impedance.

  2. Fuzzy modeling of electrical impedance tomography images of the lungs.

    Science.gov (United States)

    Tanaka, Harki; Ortega, Neli Regina Siqueira; Galizia, Mauricio Stanzione; Borges, João Batista; Amato, Marcelo Britto Passos

    2008-06-01

    Aiming to improve the anatomical resolution of electrical impedance tomography images, we developed a fuzzy model based on electrical impedance tomography's high temporal resolution and on the functional pulmonary signals of perfusion and ventilation. Electrical impedance tomography images carry information about both ventilation and perfusion. However, these images are difficult to interpret because of insufficient anatomical resolution, such that it becomes almost impossible to distinguish the heart from the lungs. Electrical impedance tomography data from an experimental animal model were collected during normal ventilation and apnea while an injection of hypertonic saline was administered. The fuzzy model was elaborated in three parts: a modeling of the heart, the pulmonary ventilation map and the pulmonary perfusion map. Image segmentation was performed using a threshold method, and a ventilation/perfusion map was generated. Electrical impedance tomography images treated by the fuzzy model were compared with the hypertonic saline injection method and computed tomography scan images, presenting good results. The average accuracy index was 0.80 when comparing the fuzzy modeled lung maps and the computed tomography scan lung mask. The average ROC curve area comparing a saline injection image and a fuzzy modeled pulmonary perfusion image was 0.77. The innovative aspects of our work are the use of temporal information for the delineation of the heart structure and the use of two pulmonary functions for lung structure delineation. However, robustness of the method should be tested for the imaging of abnormal lung conditions. These results showed the adequacy of the fuzzy approach in treating the anatomical resolution uncertainties in electrical impedance tomography images.

  3. Tunable nanogap devices for ultra-sensitive electrochemical impedance biosensing

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yong [Department of Chemistry, Wannan Medical College, Wuhu 241002 (China); Guo, Zheng [Nanomaterials and Environmental Detection Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031 (China); Song, Jing-Jing; Huang, Qin-An; Zhu, Si-Wei [Department of Chemistry, Wannan Medical College, Wuhu 241002 (China); Huang, Xing-Jiu [Nanomaterials and Environmental Detection Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031 (China); Wei, Yan, E-mail: yanwei_wnmc@hotmail.com [Department of Chemistry, Wannan Medical College, Wuhu 241002 (China)

    2016-01-28

    A wealth of research has been available discussing nanogap devices for detecting very small quantities of biomolecules by observing their electrical behavior generally performed in dry conditions. We report that a gold nanogapped electrode with tunable gap length for ultra-sensitive detection of streptavidin based on electrochemical impedance technique. The gold nanogap is fabricated using simple monolayer film deposition and in-situ growth of gold nanoparticles in a traditional interdigitated array (IDA) microelectrode. The electrochemical impedance biosensor with a 25-nm nanogap is found to be ultra-sensitive to the specific binding of streptavidin to biotin. The binding of the streptavidin hinder the electron transfer between two electrodes, resulting in a large increase in electron-transfer resistance (R{sub et}) for operating the impedance. A linear relation between the relative R{sub et} and the logarithmic value of streptavidin concentration is observed in the concentration range from 1 pM (picomolar) to 100 nM (nanomolar). The lowest detectable concentration actually measured reaches 1 pM. We believe that such an electrochemical impedance nanogap biosensor provides a useful approach towards biomolecular detection that could be extended to a number of other systems. - Highlights: • A tunable gold nanogap device was used as to electrochemical impedance biosensor. • Linear range from 1 pM to 100 nM with LOD of 1 pM for streptavidin detection was obtained. • The nanogap devices exhibit a satisfactory precision, stability, and reproducibility. • The combination of electrochemical impedance technique and nanogap devices was achieved.

  4. Bunch Length and Impedance Measurements at SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, W.J.; Cheng, W.X.; Fisher, A.S.; Huang, X.; /SLAC

    2011-11-02

    Streak camera measurements were made at SPEAR3 to characterize longitudinal coupling impedance. For the nominal optics, data was taken at three rf voltages and a single-bunch current range of 0-20mA. Both bunchcentroid phase shift and bunch lengthening were recorded to extract values for resistive and reactive impedance. An (R+L) and a Q=1 model were then back-substituted into the Haissinski equation and compared with raw profile data. In the short bunch (low-{alpha}) mode, distribution 'bursting' was observed.

  5. Electrode-less measurement of cell layers impedance.

    Science.gov (United States)

    Krůšek, J; Ďaďo, S

    2014-01-01

    This paper is devoted to yet unpublished electrode-less methods (ELM) of cell layers impedance measurement based on transformer principle. The main advantage of ELM is elimination uncertainties caused by interface between electrodes and measured electrolyte. The method of avoiding distortion caused by non-ideal transformer transfer function ("deconvolution") and errors caused by residual voltage is described. The modification of original transformer based method allowing to measure an impedance of inserted object is proposed. Results of several calibration measurements confirming the proper function of ELM including example of transepithelial resistance of cells layer are presented. Crucial parts of measuring system and recommendation for their realization are included.

  6. Impedance Studies for the Phase 2 LHC Collimators

    CERN Document Server

    Métral, E; Grudiev, A; Kroyer, T; Zotter, B; Roncarolo, F; Salvant, B

    2010-01-01

    The LHC phase 2 collimation project aims at gaining a factor ten in cleaning efficiency, robustness and impedance reduction. From the impedance point of view, several ideas emerged during the last year, such as using dielectric collimators, slots or rods in copper plates, or Litz wires. The purpose of this paper is to discuss the possible choices, showing analytical estimates, electromagnetic simulations performed using Maxwell, HFSS and GdFidL, and preliminary bench measurements. The corresponding complex tune shifts are computed for the different cases and compared on the stability diagram defined by the settings of the Landau octupoles available in the LHC at 7 TeV.

  7. Electrical impedance along connective tissue planes associated with acupuncture meridians

    Directory of Open Access Journals (Sweden)

    Hammerschlag Richard

    2005-05-01

    Full Text Available Abstract Background Acupuncture points and meridians are commonly believed to possess unique electrical properties. The experimental support for this claim is limited given the technical and methodological shortcomings of prior studies. Recent studies indicate a correspondence between acupuncture meridians and connective tissue planes. We hypothesized that segments of acupuncture meridians that are associated with loose connective tissue planes (between muscles or between muscle and bone visible by ultrasound have greater electrical conductance (less electrical impedance than non-meridian, parallel control segments. Methods We used a four-electrode method to measure the electrical impedance along segments of the Pericardium and Spleen meridians and corresponding parallel control segments in 23 human subjects. Meridian segments were determined by palpation and proportional measurements. Connective tissue planes underlying those segments were imaged with an ultrasound scanner. Along each meridian segment, four gold-plated needles were inserted along a straight line and used as electrodes. A parallel series of four control needles were placed 0.8 cm medial to the meridian needles. For each set of four needles, a 3.3 kHz alternating (AC constant amplitude current was introduced at three different amplitudes (20, 40, and 80 μAmps to the outer two needles, while the voltage was measured between the inner two needles. Tissue impedance between the two inner needles was calculated based on Ohm's law (ratio of voltage to current intensity. Results At the Pericardium location, mean tissue impedance was significantly lower at meridian segments (70.4 ± 5.7 Ω compared with control segments (75.0 ± 5.9 Ω (p = 0.0003. At the Spleen location, mean impedance for meridian (67.8 ± 6.8 Ω and control segments (68.5 ± 7.5 Ω were not significantly different (p = 0.70. Conclusion Tissue impedance was on average lower along the Pericardium meridian, but not

  8. LEIR impedance model and coherent beam instability observations

    CERN Document Server

    Biancacci, N; Migliorati, M; Rijoff, T L

    2017-01-01

    The LEIR machine is the first synchrotron in the ion ac-celeration chain at CERN and it is responsible to deliverhigh intensity ion beams to the LHC. Following the recentprogress in the understanding of the intensity limitations,detailed studies of the machine impedance started. In thiswork we describe the present LEIR impedance model, detail-ing the contribution to the total longitudinal and transverseimpedance of several machine elements. We then comparethe machine tune shift versus intensity predictions againstmeasurements at injection energy and summarize the co-herent instability observations in the absence of transversefeedback.

  9. Impedance Analysis of SOGI-FLL-Based Grid Synchronization

    DEFF Research Database (Denmark)

    Yi, Hao; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    of the Second-Order Generalized Integrator Frequency-Locked Loop (SOGI-FLL), which has been introduced for realizing grid synchronization in the stationary reference frame. The influences of the voltage perturbation on the estimated phase and further on the output current are revealed for the grid......The latest research has pointed out that the Phase-Locked Loop (PLL) plays an important role in shaping the impedance of grid-connected converters, yet most of the works so far merely focus on the synchronous reference-frame PLL. Alternatively, this letter presents the impedance analysis...

  10. Frequency-dependent magneto-impedance spectra in manganite oxides

    CERN Document Server

    Fu, C M; Lin, M L; Wen, Z H

    2000-01-01

    We present a theoretical analysis which explains the specific feature of frequency dependence of the impedance on the sintered manganese oxides, based on the classical electromagnetism. The occurrence of dielectric and magnetization response has to be taken into account in order to obtain good agreement of experimental data with the theoretical expression in a good dielectric approximation. The result implies that the specific feature of impedance spectra may be related to the interplay of high-frequency electromagnetic field with carriers in the complex dielectric as well as magnetic states.

  11. On the coupling impedance for particles with opposite velocities

    CERN Document Server

    Davino, D; Verolino, L

    2003-01-01

    As already shown by several authors, the reciprocity theorem can be rewritten as a simple formula connecting the longitudinal coupling impedances of a particle travelling in the positive and negative directions of an infinitely long vacuum chamber crossing a scattering structure (cavity, step junction, iris, etc.) of general shape. The formula is valid for any particle velocity. As an example, we consider the case of two semi-infinite circular vacuum chambers with different radii; for this case we give the explicit difference between the coupling impedances and the wake potentials. (orig.)

  12. Frequency scanning antenna arrays with pentagonal dipoles of different impedances

    Directory of Open Access Journals (Sweden)

    Bošković Nikola

    2015-01-01

    Full Text Available In this work we present the benefits of using pentagonal dipoles as radiating elements instead of classical printed dipoles in the design of frequency scanning antenna arrays. We investigate how impedance of pentagonal dipoles, which can be changed in a wide range, influences the overall characteristics of the uniform antenna array. Some very important antenna characteristics such as side lobe level, gain and scanning angle are compared for three different antenna arrays consisting of identical pentagonal dipoles with impedances of 500 Ω, 1000 Ω and 1500 Ω. [Projekat Ministarstva nauke Republike Srbije, br. TR-32024 i br. III-45016

  13. A transient model to simulate HTPEM fuel cell impedance spectra

    DEFF Research Database (Denmark)

    Vang, Jakob Rabjerg; Andreasen, Søren Juhl; Kær, Søren Knudsen

    2012-01-01

    diffusion of cathode gas species in gas diffusion layers and catalyst layer, transport of protons in the membrane and the catalyst layers, and double layer capacitive effects in the catalyst layers. The model has been fitted simultaneously to a polarization curve and to an impedance spectrum recorded......This paper presents a spatially resolved transient fuel cell model applied to the simulation of high temperature PEM fuel cell impedance spectra. The model is developed using a 2D finite volume method approach. The model is resolved along the channel and across the membrane. The model considers...

  14. Line impedance estimation using model based identification technique

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Agelidis, Vassilios; Teodorescu, Remus

    2011-01-01

    The estimation of the line impedance can be used by the control of numerous grid-connected systems, such as active filters, islanding detection techniques, non-linear current controllers, detection of the on/off grid operation mode. Therefore, estimating the line impedance can add extra functions......-passive behaviour of the proposed method comes from the combination of the non intrusive behaviour of the passive methods with a better accuracy of the active methods. The simulation results reveal the good accuracy of the proposed method....

  15. Impedance technique for measuring dielectrophoretic collection of microbiological particles

    CERN Document Server

    Allsopp, D W E; Brown, A P; Betts, W B

    1999-01-01

    Measurement of the impedance change resulting from the collection of microbiological particles at coplanar electrodes is shown to be an effective and potentially quantitative method of detecting dielectrophoresis. Strong correlations between the frequency-dependent dielectrophoretic collection characteristics measured by impedance change and those observed using an established counting method based on image analysis have been obtained for Escherichia coli. In addition it is shown that the new electrical method can be used to sense dielectrophoretic collection of 19 nm diameter latex beads, particles too small to be resolved by conventional optical detection systems. (author)

  16. High Frequency Effects of Impedances and Coatings in the CLIC Damping Rings

    CERN Document Server

    Koukovini Platia, Eirini; Rumolo, G

    The Compact Linear Collider (CLIC) is a 3 TeV eÅe¡ machine, currently under design at CERN, that targets to explore the terascale particle physics regime. The experiment requires a high luminosity of 2£1034 cm2 s¡1, which can be achieved with ultra low emittances delivered from the Damping Rings (DRs) complex. The high bunch brightness of the DRs gives rise to several collective effects that can limit the machine performance. Impedance studies during the design stage of the DR are of great importance to ensure safe operation under nominal parameters. As a first step, the transverse impedance model of the DRis built, accounting for the wholemachine. Beam dynamics simulations are performedwith HEADTAIL to investigate the effect on beam dynamics. For the correct impedancemodeling of the machine elements, knowledge of the material properties is essential up to hundreds of GHz, where the bunch spectrum extends. Specifically, Non Evaporable Getter (NEG) is a commonly used coating for good vacuumbut its properti...

  17. Correlation between capacity and impedance of lithium-ion cells during calendar and cycle life

    Science.gov (United States)

    Schuster, Simon F.; Brand, Martin J.; Campestrini, Christian; Gleissenberger, Markus; Jossen, Andreas

    2016-02-01

    Conventional capacity measurement techniques are time-consuming and thus expensive. But to know the capacity of battery units is necessary, e.g. to select most equal cells for battery pack assembly or to decide whether single units of an aged battery pack are worthy to be reused in a 2nd-life application. So, a quick and easy approach to refer to the actual capacity is of great technical and economic interest. In this paper, the correlation between capacity and impedance of lithium-ion cells during calendar and cycle life is analyzed and assessed, whether it can serve as a base for capacity quick tests. Therefore, new cells, cells aged in the laboratory and those out of two identical electric vehicles are characterized to yield a broad set of data. Results of this work imply the feasibility of correlation based capacity quick tests. However, parameterization of needed functional dependencies between capacity and impedance must be done with laboratory aging data similar to the practical use as a strong dependency of the correlation behavior from the operational and storage conditions is observed. Especially high temperature leads to strong deviation which could be linked to the layered structure of the solid electrolyte interphase.

  18. A practical guide to bioelectrical impedance analysis using the example of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Mattiucci-Guehlke Muriel

    2011-04-01

    Full Text Available Abstract Bioelectrical impedance analysis (BIA is a simple, inexpensive, quick and non-invasive technique for measuring body composition. The clinical benefit of BIA can be further enhanced by combining it with bioelectrical impedance vector analysis (BIVA. However, there is a substantial lack of information on the practical aspects of BIA/BIVA for those primarily interested in learning how to use and interpret this method in practice. The purpose of this article is to provide some guidance on the use of BIA/BIVA with special attention to practical considerations. This report reflects the authors' practical experience with the use of single-frequency BIA in combination with BIVA, particularly in COPD patients. First, the method and principles of BIA/BIVA are briefly described. Then, a practice-oriented approach to the interpretation and analysis of characteristic examples of altered nutritional and fluid status as seen with BIA/BIVA in COPD patients (e.g. malnutrition in obese and underweight patients with COPD, water retention is presented. As our examples show BIA/BIVA is an attractive and easy-to-learn tool for quick nutritional assessment and is therefore of great clinical benefit in daily practice.

  19. Distance Protection Impedance Measurement for Inhomogeneous Multiple-Circuit 400/150 kV Transmission Lines with Shared Towers

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Sigurbjörnsson, Ragnar; Bukh, Bjarne

    2016-01-01

    Combined transmission lines where different voltage levels shares same towers are used in transmission systems in order to save way of right. Faults between different voltage levels results in complex fault current distributions due to mutual couplings and the fact that the faulted phases no longer...... impedance for combined faults and thereby shed light on relay trips. This study uses actual fault records, analytical method and PSCAD simulation studies to analyse combined faults in an existing 400 and 150 kV transmission line owned by Danish TSO Energinet.dk. The results clearly show that an accurate...... are interconnected in a simple way but via transformers and infeed from remaining parts of the network. Distance relay measured fault loop impedance shows wide ranges of variations for both phase-phase loops as well as phase-earth loops. No simple relations exist. Simulation models can be used to study fault loop...

  20. Famous puzzles of great mathematicians

    CERN Document Server

    Petković, Miodrag S

    2009-01-01

    This entertaining book presents a collection of 180 famous mathematical puzzles and intriguing elementary problems that great mathematicians have posed, discussed, and/or solved. The selected problems do not require advanced mathematics, making this book accessible to a variety of readers. Mathematical recreations offer a rich playground for both amateur and professional mathematicians. Believing that creative stimuli and aesthetic considerations are closely related, great mathematicians from ancient times to the present have always taken an interest in puzzles and diversions. The goal of this

  1. Impedance Flow Cytometry as a Tool to Analyze Microspore and Pollen Quality.

    Science.gov (United States)

    Heidmann, Iris; Di Berardino, Marco

    2017-01-01

    Analyzing pollen quality in an efficient and reliable manner is of great importance to the industries involved in seed and fruit production, plant breeding, and plant research. Pollen quality parameters, viability and germination capacity, are analyzed by various staining methods or by in vitro germination assays, respectively. These methods are time-consuming, species-dependent, and require a lab environment. Furthermore, the obtained viability data are often poorly related to in vivo pollen germination and seed set. Here, we describe a quick, label-free method to analyze pollen using microfluidic chips inserted into an impedance flow cytometer (IFC). Using this approach, pollen quality parameters are determined by a single measurement in a species-independent manner. The advantage of this protocol is that pollen viability and germination can be analyzed quickly by a reliable and standardized method.

  2. Plasmonic mode converter for controlling optical impedance and nanoscale light-matter interaction.

    Science.gov (United States)

    Hung, Yun-Ting; Huang, Chen-Bin; Huang, Jer-Shing

    2012-08-27

    To enable multiple functions of plasmonic nanocircuits, it is of key importance to control the propagation properties and the modal distribution of the guided optical modes such that their impedance matches to that of nearby quantum systems and desired light-matter interaction can be achieved. Here, we present efficient mode converters for manipulating guided modes on a plasmonic two-wire transmission line. The mode conversion is achieved through varying the path length, wire cross section and the surrounding index of refraction. Instead of pure optical interference, strong near-field coupling of surface plasmons results in great momentum splitting and modal profile variation. We theoretically demonstrate control over nanoantenna radiation and discuss the possibility to enhance nanoscale light-matter interaction. The proposed converter may find applications in surface plasmon amplification, index sensing and enhanced nanoscale spectroscopy.

  3. Sampling of finite elements for sparse recovery in large scale 3D electrical impedance tomography.

    Science.gov (United States)

    Javaherian, Ashkan; Soleimani, Manuchehr; Moeller, Knut

    2015-01-01

    This study proposes a method to improve performance of sparse recovery inverse solvers in 3D electrical impedance tomography (3D EIT), especially when the volume under study contains small-sized inclusions, e.g. 3D imaging of breast tumours. Initially, a quadratic regularized inverse solver is applied in a fast manner with a stopping threshold much greater than the optimum. Based on assuming a fixed level of sparsity for the conductivity field, finite elements are then sampled via applying a compressive sensing (CS) algorithm to the rough blurred estimation previously made by the quadratic solver. Finally, a sparse inverse solver is applied solely to the sampled finite elements, with the solution to the CS as its initial guess. The results show the great potential of the proposed CS-based sparse recovery in improving accuracy of sparse solution to the large-size 3D EIT.

  4. Impedance spectroscopy of micro-Droplets reveals activation of Bacterial Mechanosensitive Channels in Hypotonic Solutions

    Science.gov (United States)

    Ebrahimi, Aida; Alam, Muhammad A.

    Rapid detection of bacterial pathogens is of great importance in healthcare, food safety, environmental monitoring, and homeland security. Most bacterial detection platforms rely on binary fission (i.e. cell growth) to reach a threshold cell population that can be resolved by the sensing method. Since cell division depends on the bacteria type, the detection time of such methods can vary from hours to days. In contrast, in this work, we show that bacteria cells can be detected within minutes by relying on activation of specific protein channels, i.e. mechanosensitive channels (MS channels). When cells are exposed to hypotonic solutions, MS channels allow efflux of solutes to the external solution which leads to release the excessive membrane tension. Release of the cytoplasmic solutes, in turn, results in increase of the electrical conductance measured by droplet-based impedance sensing. The approach can be an effective technique for fast, pre-screening of bacterial contamination at ultra-low concentration.

  5. Carbon Nanotube-Epoxy Nanocomposites: Correlation and Integration of Dynamic Impedance, Dielectric, and Mechanical Analyses

    Directory of Open Access Journals (Sweden)

    O. Moudam

    2013-01-01

    Full Text Available This study focuses on the characterization of MWNT-epoxy composites for different MWNT concentrations of 0–7 wt% by correlating different dynamic analysis techniques, including DMA, impedance, and DEA. An optimum composition was established at 0.1 wt% MWNTs corresponding to the best MWNT dispersion which resulted in the formation of an optimum MWNT network. The addition of this low fraction of MWNTs in epoxy resulted in stiffening the molecular structure and suppressing certain molecular transitions, raising the dielectric constant especially in the low-to-medium frequency range, raising the electrical conductivity especially at the high frequencies, and increasing the electromagnetic shielding effectiveness. The 0.1% MWNT-epoxy nanocomposite switched the electromagnetic shielding behaviour from being a very effective absorber at low frequencies to being an effective reflector at high frequencies. Finally, the Nyquist plot derived from the dynamic impedance spectroscopy proved most useful at providing evidence of multiple size distribution of MWNT agglomerates.

  6. A Novel 3D Thermal Impedance Model for High Power Modules Considering Multi-layer Thermal Coupling and Different Heating/Cooling Conditions

    DEFF Research Database (Denmark)

    Bahman, Amir Sajjad; Ma, Ke; Blaabjerg, Frede

    2015-01-01

    accurate temperature estimation either vertically or horizontally inside the power devices is still hard to identify. This paper investigates the thermal behavior of high power module in various operating conditions by means of Finite Element Method (FEM). A novel 3D thermal impedance network considering......Thermal management of power electronic devices is essential for reliable performance especially at high power levels. One of the most important activities in the thermal management and reliability improvement is acquiring the temperature information in critical points of the power module. However...... the multi-layer thermal coupling among chips is proposed. The impacts to the thermal impedance by various cooling and heating conditions are also studied. It is concluded that the heating and cooling conditions will have influence on the junction to case thermal impedances and need to be carefully...

  7. Impedance spectroscopy studies of surface engineered TiO2 ...

    Indian Academy of Sciences (India)

    Administrator

    Abstract. Dielectric analysis of nanometre range size ceramic particles like TiO2 is very important in the understanding of the performance and design of their polymer nanocomposites for energy storage and other applications. In recent times, impedance spectroscopy is shown to be a very powerful tool to investigate the.

  8. Effect of Zr on dielectric, ferroelectric and impedance properties of ...

    Indian Academy of Sciences (India)

    Administrator

    dielectric constant value of BZT ceramic, its piezoelectric and impedance properties are less studied in the litera- ture. To further understand the grain and grain boundary effects in these ceramics, the temperature and frequency dependence of electrical and dielectric properties at high temperatures (30 to 600°C) have been ...

  9. Analysis of the willow root system by electrical impedance spectroscopy.

    Science.gov (United States)

    Cao, Yang; Repo, Tapani; Silvennoinen, Raimo; Lehto, Tarja; Pelkonen, Paavo

    2011-01-01

    Information on plant roots is increasingly needed for understanding and managing plants under various environmental conditions, including climate change. Several methods have been developed to study fine roots but they are either destructive or cumbersome, or may not be suitable for studies of fine root functionality. Electrical impedance, resistance, and capacitance have been proposed as possible non-destructive measures for studying roots. Their use is limited by a lack of knowledge concerning the electrical circuit of the system. Electrical impedance spectroscopy (EIS) was used for hydroponically raised willows (Salix schwerinii) to estimate the root system size. The impedance spectra were investigated in three experimental set-ups and the corresponding appropriate lumped models were formulated. The fit of the proposed lumped models with the measured impedance spectra data was good. The model parameters were correlated with the contact area of the roots and/or stems raised in the hydroponic solution. The EIS method proved a useful non-destructive method for assessing root surface area. This work may be considered to be a new methodological contribution to understanding root systems and their functions in a non-destructive manner.

  10. Efficiency of wave impeding barrier in pipeline construction under ...

    Indian Academy of Sciences (India)

    They should be protected from earthquake disaster especially when they pass through high seismicity zones. The installation of wave impeding barriers (WIB) below the vulnerable infrastructures as pipelines established in soft soil can be used to reduce the effect of the earthquake induced ground borne vibrations. In this ...

  11. Generalized Warburg impedance on realistic self-affine fractals ...

    Indian Academy of Sciences (India)

    Administrator

    Generalized Warburg impedance on realistic self-affine fractals: Comparative study of statistically corrugated and isotropic roughness. RAJESH KUMAR and RAMA KANT. Journal of Chemical Sciences, Vol. 121, No. 5, September 2009, pp. 579–588. 1. ( ) c. L. R ω on page 582, column 2, para 2, after eq (8) should read as ...

  12. Longitudinal impedance of LHC version-1 stripline beam position monitor

    CERN Document Server

    Vos, L

    1997-01-01

    The electrodes in the first version of the LHC beam position monitor are 50 \\W striplines. An enlarged aperture is required to keep the inner face of the electrodes in the shadow of the mechanical aperture of the machine. The longitudinal impedance of this device consists of two distinct components, one from the cavity and the other from the electrodes. The cavity part of the impedance can be reduced by inter-electrode shields as proposed by G. Lambertson. A complementary way of reducing this part of the impedance is to use tapered edges. The cavity wake potential of the beam position monitor is computed both with the 3D code MAFIA and analytically for a very short bunch (20 mm) and for a normal high energy LHC bunch (75 mm). The computation is done separately for the inter-electrode shields and for the tapered ends. The agreement between the two methods is very good, hence it can be concluded that the cavity impedance of the monitor cavity is well known up to the cut-off frequency of the LHC pipe (5.1 GHz). ...

  13. Lower leg electrical impedance after distal bypass surgery

    DEFF Research Database (Denmark)

    Belanger, G K; Bolbjerg, M L; Heegaard, N H

    1998-01-01

    Electrical impedance was determined in 13 patients following distal bypass surgery to evaluate lower leg oedema as reflected by its circumference. Tissue injury was assessed by the plasma concentration of muscle enzymes. After surgery, the volume of the control lower leg increased from 1250 (816...... to be a useful method for the evaluation of lower leg oedema after distal bypass surgery....

  14. The bioelectrical impedance vector migration in healthy infants

    NARCIS (Netherlands)

    L'Abee, Carianne; Poorts-Borger, Petra H.; Gorter, Erna H. G. M.; Piccoli, Antonio; Stolk, Ronald P.; Sauer, Pieter J. J.

    Background & aims: Detecting young children with high amount of body fat is important to intervene in the development of obesity. The aim of this study is to gain inside in the bioelectrical impedance vector analysis in healthy infants. Methods: Repeated measurements of whole body reactance and

  15. Three-dimensional electrical impedance tomography: a topology optimization approach.

    Science.gov (United States)

    Mello, Luís Augusto Motta; de Lima, Cícero Ribeiro; Amato, Marcelo Britto Passos; Lima, Raul Gonzalez; Silva, Emílio Carlos Nelli

    2008-02-01

    Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.

  16. Cultural Saga: Does Pakhtun Culture Impede Women Employment ...

    African Journals Online (AJOL)

    Cultural Saga: Does Pakhtun Culture Impede Women Employment? Humera Jamal, Mussawar Shah, Sidra Iqbal, Asad Ullah, Imran Imran. Abstract. Aim of this research article embodies the measurement of attitude of teaching faculty in Peshawar University to assess cultural impediments with reference to women ...

  17. BIOELECTRICAL IMPEDANCE VECTOR ANALYSIS IDENTIFIES SARCOPENIA IN NURSING HOME RESIDENTS

    Science.gov (United States)

    Loss of muscle mass and water shifts between body compartments are contributing factors to frailty in the elderly. The body composition changes are especially pronounced in institutionalized elderly. We investigated the ability of single-frequency bioelectrical impedance analysis (BIA) to identify b...

  18. Relationship between bioelectrical impedance-derived estimates of ...

    African Journals Online (AJOL)

    Measurements of basal metabolic rate (BMR) and body composition parameters represent an important tool for preventing obesity. This investigation examined the relationships between bioelectrical impedance-derived estimates of BMR and various body composition parameters, including age, body mass index, ...

  19. Does strategic planning enhance or impede innovation and firm performance

    NARCIS (Netherlands)

    Song, Michael; Im, Subin; van der Bijl, H.M.; Song, Lisa Z.

    2011-01-01

    Does strategic planning enhance or impede innovation and firm performance? The current literature provides contradictory views. This study extends the resource-advantage theory to examine the conditions in which strategic planning increases or decreases the number of new product development projects

  20. Does strategic planning enhance or impede innovation and firm performance?

    NARCIS (Netherlands)

    Song, Michael; Im, Subin; van der Bij, Hans; Song, Lisa Z.

    Does strategic planning enhance or impede innovation and firm performance? The current literature provides contradictory views. This study extends the resource-advantage theory to examine the conditions in which strategic planning increases or decreases the number of new product development projects

  1. Contactless Impedance Sensors and Their Application to Flow Measurements

    Directory of Open Access Journals (Sweden)

    Karel Štulík

    2013-02-01

    Full Text Available The paper provides a critical discussion of the present state of the theory of high-frequency impedance sensors (now mostly called contactless impedance or conductivity sensors, the principal approaches employed in designing impedance flow-through cells and their operational parameters. In addition to characterization of traditional types of impedance sensors, the article is concerned with the use of less common sensors, such as cells with wire electrodes or planar cells. There is a detailed discussion of the effect of the individual operational parameters (width and shape of the electrodes, detection gap, frequency and amplitude of the input signal on the response of the detector. The most important problems to be resolved in coupling these devices with flow-through measurements in the liquid phase are also discussed. Examples are given of cell designs for continuous flow and flow-injection analyses and of detection systems for miniaturized liquid chromatography and capillary electrophoresis. New directions for the use of these sensors in molecular biology and chemical reactors and some directions for future development are outlined.

  2. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition

    Directory of Open Access Journals (Sweden)

    Fu-Tai Wang

    2015-07-01

    Full Text Available Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD can decompose a signal into several intrinsic mode functions (IMFs that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method.

  3. Effect of rib-cage structure on acoustic chest impedance

    DEFF Research Database (Denmark)

    Zimmermann, Niels Henrik; Møller, Henrik; Hansen, John

    2011-01-01

    When a stethoscope is placed on the surface of the chest, the coupler picks up sound from heart and lungs transmitted through the tissues of the ribcage and from the surface of the skin. If the acoustic impedance of the chest surface is known, it is possible to optimize the coupler for picking up...

  4. An Improved Very Low-Power Electrode Contact Impedance Monitor

    Directory of Open Access Journals (Sweden)

    Burke Martin J

    2016-01-01

    Full Text Available This paper reports the design improvement of a circuit for monitoring the quality of contact of un-gelled stainless steel electrodes with a patient’s skin in the measurement of the ECG. The circuit is intended to be incorporated into a heart rate monitor used prior to and during childbirth to measure the mother’s heart rate. The revised design uses commercially available low-power technology to implement the circuit with a reduction in the power consumption by a factor of 20 over a previous design [1]. The circuit measures the quality of contact of electrode impedances up to 100kΩ and gives a visual indication when the contact impedance of either electrode is above this level. The impedance is measured using a signal injected through the electrodes via the input impedance of the amplifier at a frequency of 5kHz. The resulting signal present at the amplifier input at this frequency is then extracted and processed before threshold detection of the signal level which is used to indicate whether or not the quality of contact of the patient’s fingers with the electrodes is acceptable for the purposes of heart rate measurement.

  5. Impedance Spectra of Activating/Passivating Solid Oxide Electrodes

    DEFF Research Database (Denmark)

    Mogensen, Mogens Bjerg; Sun, Xiufu; Koch, Søren

    2014-01-01

    Fuel Cells (SOFC) and Electrolyser Cells (SOEC) exist. Not all of them are irreversible, especially not over short periods. A reversible degradation is termed “passivation” and the reverse is then “activation”. These processes may exhibit themselves in the Electrochemical Impedance Spectra (EIS...

  6. A note on the MUSIC algorithm for impedance tomography

    Science.gov (United States)

    Hanke, Martin

    2017-02-01

    We investigate the MUSIC algorithm for the reconstruction of small (infinitesimal) inclusions inside a planar homogeneous object from discrete impedance tomography data within the framework of the gap electrode model. We provide a justification of the method whenever the number of electrodes exceeds 2(J  +  1) where J is the number of the inclusions to be found.

  7. Monitoring of yeast cell concentration using a micromachined impedance sensor

    NARCIS (Netherlands)

    Krommenhoek, E.E.; Gardeniers, Johannes G.E.; Bomer, Johan G.; van den Berg, Albert; Li, X.; Ottens, M.; van der Wielen, L.A.M.; van Dedem, G.W.K.; van Leeuwen, M.; van Gulik, W.M.; Heijnen, J.J.

    2005-01-01

    The paper describes the design, modelling and experimental characterization of a micromachined impedance sensor for on-line monitoring of the viable yeast cell concentration (biomass) in a miniaturized cell assay. Measurements in a Saccharomyces cerevisiae cell culture show that the permittivity of

  8. Monitoring of yeast cell concentration using a micromachnined impedance sensor

    NARCIS (Netherlands)

    Krommenhoek, E.E.; Gardeniers, Johannes G.E.; Bomer, Johan G.; van den Berg, Albert; Li, X.; Li, X.; Ottens, M.; van der Wielen, L.A.M.; van Dedem, G.W.K.; van Leeuwen, M.; van Gulik, W.M.; Heijnen, J.J.

    2006-01-01

    This paper describes the design, modeling and experimental characterization of a micromachined impedance sensor for on-line monitoring of the viable yeast cell concentration (biomass) in a miniaturized cell assay. Measurements in Saccharomyces cerevisiae cell culture show that the characteristic

  9. A modified impedance control for physical interaction of UAVs

    NARCIS (Netherlands)

    Fumagalli, Matteo; Carloni, Raffaella

    2013-01-01

    This paper proposes a modified impedance control strategy for a generic robotic system that can interact with an unknown environment or can be moved by a human. The controller makes use of a virtual mass, coupled to the robotic system, which allows for stable interaction. The focus is mainly on

  10. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module...

  11. Impedance planimetric description of normal rectoanal motility in humans

    DEFF Research Database (Denmark)

    Andersen, Inge S; Michelsen, Hanne B; Krogh, Klaus

    2007-01-01

    the experiment, the cross-sectional area at all channels showed strong cyclic contractile activity and the anal pressure increased by approximately 100 percent. CONCLUSIONS: The new rectal impedance planimetry system allows highly detailed description of rectoanal motility patterns. It has promise as a new...... method for description of rectoanal motility in further studies. Udgivelsesdato: 2007-Nov...

  12. Design methodology to enhance high impedance surfaces performances

    Directory of Open Access Journals (Sweden)

    M. Grelier

    2014-04-01

    Full Text Available A methodology is introduced for designing wideband, compact and ultra-thin high impedance surfaces (HIS. A parametric study is carried out to examine the effect of the periodicity on the electromagnetic properties of an HIS. This approach allows designers to reach the best trade-off for HIS performances.

  13. Organic electrochemical transistors for cell-based impedance sensing

    Energy Technology Data Exchange (ETDEWEB)

    Rivnay, Jonathan, E-mail: rivnay@emse.fr, E-mail: owens@emse.fr; Ramuz, Marc; Hama, Adel; Huerta, Miriam; Owens, Roisin M., E-mail: rivnay@emse.fr, E-mail: owens@emse.fr [Department of Bioelectronics, Ecole des Mines de St. Etienne, 13541 Gardanne (France); Leleux, Pierre [Department of Bioelectronics, Ecole des Mines de St. Etienne, 13541 Gardanne (France); Microvitae Technologies, Pole d' Activite Y. Morandat, 13120 Gardanne (France)

    2015-01-26

    Electrical impedance sensing of biological systems, especially cultured epithelial cell layers, is now a common technique to monitor cell motion, morphology, and cell layer/tissue integrity for high throughput toxicology screening. Existing methods to measure electrical impedance most often rely on a two electrode configuration, where low frequency signals are challenging to obtain for small devices and for tissues with high resistance, due to low current. Organic electrochemical transistors (OECTs) are conducting polymer-based devices, which have been shown to efficiently transduce and amplify low-level ionic fluxes in biological systems into electronic output signals. In this work, we combine OECT-based drain current measurements with simultaneous measurement of more traditional impedance sensing using the gate current to produce complex impedance traces, which show low error at both low and high frequencies. We apply this technique in vitro to a model epithelial tissue layer and show that the data can be fit to an equivalent circuit model yielding trans-epithelial resistance and cell layer capacitance values in agreement with literature. Importantly, the combined measurement allows for low biases across the cell layer, while still maintaining good broadband signal.

  14. Advanced impedance modeling of solid oxide electrochemical cells

    DEFF Research Database (Denmark)

    Graves, Christopher R.; Hjelm, Johan

    2014-01-01

    ) constraining the parameter values during fitting to ranges of physically reasonable values. Using these methods, the number of fitting parameters for four impedance spectra measured with isolated changes to the fuel and oxidant gas compositions, has been reduced from 80 to 21-34 depending on the model...

  15. Generalized Warburg impedance on realistic self-affine fractals ...

    Indian Academy of Sciences (India)

    ... Refresher Courses · Symposia · Live Streaming. Home; Journals; Journal of Chemical Sciences; Volume 121; Issue 5. Generalized Warburg impedance on realistic self-affine fractals: Comparative study of statistically corrugated and isotropic roughness. Rajesh Kumar Rama Kant. Volume 121 Issue 5 September 2009 pp ...

  16. Estimation of surface impedance using different types of microphone arrays

    DEFF Research Database (Denmark)

    Richard, Antoine Philippe André; Fernandez Grande, Efren; Brunskog, Jonas

    2017-01-01

    and the particle velocity leads to an estimation of the surface impedance for a given angle of incidence. A porous type absorber sample is tested experimentally in anechoic conditions for different array geometries, sample sizes, incidence angles, and distances between the array and sample. In particular...

  17. Something different - caching applied to calculation of impedance matrix elements

    CSIR Research Space (South Africa)

    Lysko, AA

    2012-09-01

    Full Text Available This paper introduces a new method generally termed memoization, to accelerate filling in the impedance matrix, e.g. in the method of moments (MoM). The memoization stores records for recently computed matrix elements in a cache, and, when...

  18. Barriers that impede the effectiveness of precautionary measures of ...

    African Journals Online (AJOL)

    The quantitative method and stratified random sampling was used. Data was analysed using Statistical Package of Social Sciences (SPSS) and Microsoft excel. The study established that there are many barriers that impede the effectiveness of precautionary measures of fighting the spread of HIV and AIDS in these tertiary ...

  19. Sparsity prior for electrical impedance tomography with partial data

    DEFF Research Database (Denmark)

    Garde, Henrik; Knudsen, Kim

    2016-01-01

    This paper focuses on prior information for improved sparsity reconstruction in electrical impedance tomography with partial data, i.e. Cauchy data measured on subsets of the boundary. Sparsity is enforced using an (Formula presented.) norm of the basis coefficients as the penalty term...

  20. Impedance-based damage identification enhancement via tunable piezoelectric circuitry

    Science.gov (United States)

    Kim, Jinki; Wang, K. W.

    2014-03-01

    The piezoelectric impedance-based method for damage detection has been explored extensively for its high sensitivity to small-sized damages with low-cost measurement circuit which enables remote damage monitoring. While the method has good potential, the amount of feasible impedance data is usually much less than the number of required system parameters to accurately identify the damage location/severity via an inverse formulation. This data incompleteness forms a highly underdetermined problem and because of this numerical ill-conditioning, the predicted damage parameters will be significantly influenced by unavoidable measurement noise and the accuracy of the base-line model. In this study, the state of the art of impedance-based damage identification is advanced by incorporating a tunable piezoelectric circuitry with the structure to enrich the impedance measurements. This piezoelectric circuitry introduces additional degrees of freedom to the structure and changes the dynamics of the coupled system. By tuning the inductance value, it is possible to perform various measurements under different system dynamics which reflects the damage effect. Therefore, if performed systematically, notably increased sets of measurement can be obtained, which will improve the inverse problem to be less underdetermined. Clearly, we can expect the accuracy and robustness in damage identification to be significantly enhanced. Numerical case study on localizing damage in a fixed-fixed beam using spectral element method is performed to demonstrate the effectiveness of the new method for structural damage identification.

  1. Propagation of singularities for linearised hybrid data impedance tomography

    DEFF Research Database (Denmark)

    Bal, Guillaume; Hoffmann, Kristoffer; Knudsen, Kim

    2017-01-01

    For a general formulation of linearised hybrid inverse problems in impedance tomography, the qualitative properties of the solutions are analysed. Using an appropriate scalar pseudo-differential formulation, the problems are shown to permit propagating singularities under certain non-elliptic con...

  2. Enhancement of antenna-coupled microbolometers response by impedance matching

    Directory of Open Access Journals (Sweden)

    Jorge Simón

    2015-10-01

    Full Text Available Metallic structures were evaluated to determine the one best matches impedance between lithographic antennas and microbolometers. The best was a 0.28λ transmission line section between the antenna and the microbolometer, 12% longer than what RF theory sets, whose behaviour was compared with other structures. The response was 360% higher.

  3. The Great Gatsby. [Lesson Plan].

    Science.gov (United States)

    Zelasko, Ken

    Based on F. Scott Fitzgerald's novel "The Great Gatsby," this lesson plan presents activities designed to help students understand that adapting part of a novel into a dramatic reading makes students more intimate with the author's intentions and craft; and that a part of a novel may lend itself to various oral interpretations. The main activity…

  4. Great Basin wildlife disease concerns

    Science.gov (United States)

    Russ Mason

    2008-01-01

    In the Great Basin, wildlife diseases have always represented a significant challenge to wildlife managers, agricultural production, and human health and safety. One of the first priorities of the U.S. Department of Agriculture, Division of Fish and Wildlife Services was Congressionally directed action to eradicate vectors for zoonotic disease, particularly rabies, in...

  5. The Great Bug Hunt 2011

    Science.gov (United States)

    Dixon-Watmough, Rebecca

    2011-01-01

    The Association For Science Education's "schoolscience.co.uk Great Bug Hunt 2011," in association with Martin Rapley and Gatekeeper Educational, has been a resounding success--not only because it fits into the science curriculum so neatly, but also because of the passion it evoked in the children who took part. This year's entries were…

  6. Extracting information from multiplex networks.

    Science.gov (United States)

    Iacovacci, Jacopo; Bianconi, Ginestra

    2016-06-01

    Multiplex networks are generalized network structures that are able to describe networks in which the same set of nodes are connected by links that have different connotations. Multiplex networks are ubiquitous since they describe social, financial, engineering, and biological networks as well. Extending our ability to analyze complex networks to multiplex network structures increases greatly the level of information that is possible to extract from big data. For these reasons, characterizing the centrality of nodes in multiplex networks and finding new ways to solve challenging inference problems defined on multiplex networks are fundamental questions of network science. In this paper, we discuss the relevance of the Multiplex PageRank algorithm for measuring the centrality of nodes in multilayer networks and we characterize the utility of the recently introduced indicator function Θ̃(S) for describing their mesoscale organization and community structure. As working examples for studying these measures, we consider three multiplex network datasets coming for social science.

  7. Impedance cardiography: Pulsatile blood flow and the biophysical and electrodynamic basis for the stroke volume equations

    Directory of Open Access Journals (Sweden)

    Donald P Bernstein

    2010-01-01

    Full Text Available Impedance cardiography (ICG is a branch of bioimpedance pimarily concerned with the determination of left ventricular stroke volume (SV. As implemented, using the transthoracic approach, the technique involves applying a current field longitudinally across a segment of thorax by means of a constant magnitude, high frequency, low amplitude alternating current (AC. By Ohm's Law, the voltage difference measured within the current field is proportional to the electrical impedance Z (Ω. Without ventilatory or cardiac activity, Z is known as the transthoracic, static base impedance Z0. Upon ventricular ejection, a characteristic time dependent cardiac-synchronous pulsatile impedance change is obtained, ΔZ(t, which, when placed electrically in parallel with Z0, constitutes the time-variable total transthoracic impedance Z(t. ΔZ(t represents a dual-element composite waveform, which comprises both the radially-oriented volumetric expansion of and axially-directed forward blood flow within both great thoracic arteries. In its majority, however, ΔZ(t is known to primarily emanate from the ascending aorta. Conceptually, commonly implemented methods assume a volumetric origin for the peak systolic upslope of ΔZ(t, (i.e. dZ/dtmax, with the presumed units of Ω·s-1. A recently introduced method assumes the rapid ejection of forward flowing blood in earliest systole causes significant changes in the velocity-induced blood resistivity variation (Δρb(t, Ωcm·s-1, and it is the peak rate of change of the blood resistivity variation dρb(t/dtmax (Ωcm·s-2 that is the origin of dZ/dtmax. As a consequence of dZ/dtmax peaking in the time domain of peak aortic blood acceleration, dv/dtmax (cm·s-2, it is suggested that dZ/dtmax is an ohmic mean acceleration analog (Ω·s-2 and not a mean flow or velocity surrogate as generally assumed. As conceptualized, the normalized value, dZ/dtmax/Z0, is a dimensionless ohmic mean acceleration equivalent (s-2

  8. Impedance Analysis of Silicon Nanowire Lithium Ion Battery Anodes

    KAUST Repository

    Ruffo, Riccardo

    2009-07-02

    The impedance behavior of silicon nanowire electrodes has been investigated to understand the electrochemical process kinetics that influences the performance when used as a high-capacity anode in a lithium ion battery. The ac response was measured by using impedance spectroscopy in equilibrium conditions at different lithium compositions and during several cycles of charge and discharge in a half cell vs. metallic lithium. The impedance analysis shows the contribution of both surface resistance and solid state diffusion through the bulk of the nanowires. The surface process is dominated by a solid electrolyte layer (SEI) consisting of an inner, inorganic insoluble part and several organic compounds at the outer interface, as seen by XPS analysis. The surface resistivity, which seems to be correlated with the Coulombic efficiency of the electrode, grows at very high lithium contents due to an increase in the inorganic SEI thickness. We estimate the diffusion coefficient of about 2 × 10 -10 cm 2/s for lithium diffusion in silicon. A large increase in the electrode impedance was observed at very low lithium compositions, probably due to a different mechanism for lithium diffusion inside the wires. Restricting the discharge voltage to 0.7 V prevents this large impedance and improves the electrode lifetime. Cells cycled between 0.07 and 0.70 V vs. metallic lithium at a current density of 0.84 A/g (C/5) showed good Coulombic efficiency (about 99%) and maintained a capacity of about 2000 mAh/g after 80 cycles. © 2009 American Chemical Society.

  9. PEM fuel cell impedance at open circuit: PEMFC cathode vs SOFC anode

    OpenAIRE

    Kulikovsky, Andrei

    2016-01-01

    A physical model for PEM fuel cell impedance Z at open circuit potential (OCP) is developed and analytical expression for Z is derived. The OCP impedance is a sum of the cathode catalyst layer (CCL) and the gas–diffusion layer (GDL) impedances connected in series. The GDL impedance differs from the Warburg impedance, which is often used in modeling of fuel cell electrodes. A key parameter determining the OCP impedance spectrum is the Newman’s dimensionless reaction penetration depth ε. In PEM...

  10. Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Li, YunWei; Blaabjerg, Frede

    2015-01-01

    The virtual impedance concept is increasingly used for the control of power electronic systems. Generally, the virtual impedance loop can either be embedded as an additional degree of freedom for active stabilization and disturbance rejection, or be employed as a command reference generator...... for the converters to provide ancillary services. This paper presents an overview of the virtual-impedance-based control strategies for voltage-source and current-source converters. The control output impedance shaping attained by the virtual impedances is generalized first using the impedance-based models...

  11. Microfluidic Impedance Flow Cytometry Enabling High-Throughput Single-Cell Electrical Property Characterization

    Directory of Open Access Journals (Sweden)

    Jian Chen

    2015-04-01

    Full Text Available This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1 early developments of microfluidic impedance flow cytometry for single-cell electrical property characterization; (2 microfluidic impedance flow cytometry with enhanced sensitivity; (3 microfluidic impedance and optical flow cytometry for single-cell analysis and (4 integrated point of care system based on microfluidic impedance flow cytometry. We examine the advantages and limitations of each technique and discuss future research opportunities from the perspectives of both technical innovation and clinical applications.

  12. Microfluidic impedance flow cytometry enabling high-throughput single-cell electrical property characterization.

    Science.gov (United States)

    Chen, Jian; Xue, Chengcheng; Zhao, Yang; Chen, Deyong; Wu, Min-Hsien; Wang, Junbo

    2015-04-29

    This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1) early developments of microfluidic impedance flow cytometry for single-cell electrical property characterization; (2) microfluidic impedance flow cytometry with enhanced sensitivity; (3) microfluidic impedance and optical flow cytometry for single-cell analysis and (4) integrated point of care system based on microfluidic impedance flow cytometry. We examine the advantages and limitations of each technique and discuss future research opportunities from the perspectives of both technical innovation and clinical applications.

  13. An Impedance-Based Stability Analysis Method for Paralleled Voltage Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    is assessed based on a series of Nyquist diagrams drawn for the terminal impedance of each converter. Thus, the effect of the right half-plane zeros of terminal impedances in the derivation of impedance ratio for paralleled source-source converters is avoided. The interaction between the terminal impedance......This paper analyses the stability of paralleled voltage source converters in AC distributed power systems. An impedance-based stability analysis method is presented based on the Nyquist criterion for multiloop system. Instead of deriving the impedance ratio as usual, the system stability...

  14. Net Neutrality: The Great Debate

    Science.gov (United States)

    Connolly, Mary

    2015-01-01

    FCC Chairman Tom Wheeler, speaking at the International Consumer Electronics Show in January, called for an open Internet which would make sure that ISPs had economic incentives to build better networks while still protecting consumers and innovators. His specific recommendations were shared with the other members of the FCC in February. One of…

  15. Debye potentials, electromagnetic reciprocity and impedance boundary conditions for efficient analytic approximation of coupling impedances in complex heterogeneous accelerator pipes

    Energy Technology Data Exchange (ETDEWEB)

    Petracca, S. [Salerno Univ. (Italy)

    1996-08-01

    Debye potentials, the Lorentz reciprocity theorem, and (extended) Leontovich boundary conditions can be used to obtain simple and accurate analytic estimates of the longitudinal and transverse coupling impedances of (piecewise longitudinally uniform) multi-layered pipes with non simple transverse geometry and/or (spatially inhomogeneous) boundary conditions. (author)

  16. Impedance of SOFC electrodes: A review and a comprehensive case study on the impedance of LSM:YSZ cathodes

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Hjelm, Johan

    2014-01-01

    temperatures and hence different microstructures and varying degrees of LSM/YSZ solid state interactions. LSM based composite cathodes, where YSZ was replaced with CGO was also studied in order to acquire further knowledge on the chemical compatibility between LSM and YSZ. All impedance measurements were...

  17. Modeling and Grid impedance Variation Analysis of Parallel Connected Grid Connected Inverter based on Impedance Based Harmonic Analysis

    DEFF Research Database (Denmark)

    Kwon, JunBum; Wang, Xiongfei; Bak, Claus Leth

    2014-01-01

    This paper addresses the harmonic compensation error problem existing with parallel connected inverter in the same grid interface conditions by means of impedance-based analysis and modeling. Unlike the single grid connected inverter, it is found that multiple parallel connected inverters and grid...

  18. Innovation embedded in entrepreneurs’ networks in private and public spheres

    DEFF Research Database (Denmark)

    Schøtt, Thomas; Cheraghi, Maryam; Rezaei, Shahamak

    2014-01-01

    Global studies have found tendencies: traditional culture promotes entrepreneurs' networking in the private sphere, impeding innovation, whereas secular-rational culture facilitates networking in the public sphere, benefiting innovation. This embeddedness is here scrutinised in contrasting...... societies, China and Denmark. Global Entrepreneurship Monitor has surveyed entrepreneurs in China, Denmark and elsewhere. Analyses reconfirm the global tendencies and show that, China in contrast to Denmark, public sphere networking is sparser, but private sphere networking is denser. Innovation...

  19. Innovation embedded in entrepreneurs' networks in private and public spheres

    DEFF Research Database (Denmark)

    Schøtt, Thomas; Cheraghi, Maryam; Rezaei, Shahamak

    2014-01-01

    Global studies have found tendencies: traditional culture promotes entrepreneurs' networking in the private sphere, impeding innovation, whereas secular-rational culture facilitates networking in the public sphere, benefiting innovation. This embeddedness is here scrutinised in contrasting...... societies, China and Denmark. Global Entrepreneurship Monitor has surveyed entrepreneurs in China, Denmark and elsewhere. Analyses reconfirm the global tendencies and show that, China in contrast to Denmark, public sphere networking is sparser, but private sphere networking is denser. Innovation...

  20. PREFACE: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT)

    Science.gov (United States)

    Pliquett, Uwe

    2013-04-01

    Over recent years advanced measurement methods have facilitated outstanding achievements not only in medical instrumentation but also in biotechnology. Impedance measurement is a simple and innocuous way to characterize materials. For more than 40 years biological materials, most of them based on cells, have been characterized by means of electrical impedance for quality control of agricultural products, monitoring of biotechnological or food processes or in health care. Although the list of possible applications is long, very few applications successfully entered the market before the turn of the century. This was, on the one hand, due to the low specificity of electrical impedance with respect to other material properties because it is influenced by multiple factors. On the other hand, equipment and methods for many potential applications were not available. With the appearance of microcontrollers that could be easily integrated in applications at the beginning of the 1980s, impedance measurement advanced as a valuable tool in process optimization and lab automation. However, established methods and data processing were mostly used in a new environment. This has changed significantly during the last 10 years with a dramatic growth of the market for medical instrumentation and also for biotechnological applications. Today, advanced process monitoring and control require fast and highly parallel electrical characterization which in turn yields incredible data volumes that must be handled in real time. Many newer developments require miniaturized but precise sensing methods which is one of the main parts of Lab-on-Chip technology. Moreover, biosensors increasingly use impedometric transducers, which are not compatible with the large expensive measurement devices that are common in the laboratory environment. Following the achievements in the field of bioimpedance measurement, we will now witness a dramatic development of new electrode structures and electronics