WorldWideScience

Sample records for net radiant heat

  1. Radiant Heating and Cooling Systems. Part one

    DEFF Research Database (Denmark)

    Kim, Kwan Woo; Olesen, Bjarne W.

    2015-01-01

    The use of radiant heating systems has several thousand years of history.1,2 The early stage of radiant system application was for heating purposes, where hot air from flue gas (cooking, fires) was circulated under floors or in walls. After the introduction of plastic piping water-based radiant h...

  2. Semen quality in welders exposed to radiant heat.

    OpenAIRE

    Bonde, J P

    1992-01-01

    Several studies suggest that welding is detrimental to the male reproductive system. Welding fume and radiant heat are of interest as possible causal factors. This study investigates semen quality and sex hormone concentrations among 17 manual metal arc alloyed steel welders with a moderate exposure to radiant heat (globe temperature ranging from 31.1 degrees to 44.8 degrees C), but without substantial exposure to welding fume toxicants. During exposure to heat the skin temperature in the gro...

  3. Radiant Heating and Cooling Systems. Part two

    DEFF Research Database (Denmark)

    Kim, Kwan Woo; Olesen, Bjarne W.

    2015-01-01

    Control of the heating and cooling system needs to be able to maintain the indoor temperatures within the comfort range under the varying internal loads and external climates. To maintain a stable thermal environment, the control system needs to maintain the balance between the heat gain/loss of ...

  4. Radiant heat increases piglets’ use of the heated creep area on the critical days after birth

    DEFF Research Database (Denmark)

    Larsen, Mona Lilian Vestbjerg; Thodberg, Karen; Pedersen, Lene Juul

    2017-01-01

    The aim of the present study was to investigate how piglets’ use of a creep area is affected by using radiant heat compared to an incandescent light bulb. It was hypothesised that radiant heat would increase the use of the creep area. Twenty litters were randomly assigned to one of two heat sources...... in the creep area: (1) an incandescent light bulb (STANDARD, n=10) or (2) a radiant heat source (RADIANT, n=10) with five of each type of heat source in each of two batches. Observations on piglets’ position in the pen were made by scan sampling every ten minutes in a 4-hour period from 1100 to 1500 h on day 1...

  5. Study on coal char ignition by radiant heat flux.

    Science.gov (United States)

    Korotkikh, A. G.; Slyusarskiy, K. V.

    2017-11-01

    The study on coal char ignition by CO2-continuous laser was carried out. The coal char samples of T-grade bituminous coal and 2B-grade lignite were studied via CO2-laser ignition setup. Ignition delay times were determined at ambient condition in heat flux density range 90–200 W/cm2. The average ignition delay time value for lignite samples were 2 times lower while this difference is larger in high heat flux region and lower in low heat flux region. The kinetic constants for overall oxidation reaction were determined using analytic solution of simplified one-dimensional heat transfer equation with radiant heat transfer boundary condition. The activation energy for lignite char was found to be less than it is for bituminous coal char by approximately 20 %.

  6. Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit

    Directory of Open Access Journals (Sweden)

    Xiang-Long Liu

    2012-01-01

    Full Text Available Radiant floor heating has received increasing attention due to its diverse advantages, especially the energy saving as compared to the conventional dwelling heating system. This paper presents a numerical investigation of airflow and heat transfer in the slot-vented room with the radiant floor heating unit. Combination of fluid convection and thermal radiation has been implemented through the thermal boundary conditions. Spatial distributions of indoor air temperature and velocity, as well as the heat transfer rates along the radiant floor and the outer wall, have been presented and analyzed covering the domains from complete natural convection to forced convection dominated flows. The numerical results demonstrate that the levels of average temperature in the room with lateral slot-ventilation are higher than those without slot-ventilation, but lower than those in the room with ceiling slot-ventilation. Overall, the slot-ventilation room with radiant floor heating unit could offer better indoor air quality through increasing the indoor air temperature and fresh air exchanging rate simultaneously. Concerning the airborne pollutant transports and moisture condensations, the performance of radiant floor heating unit will be further optimized in our future researches.

  7. Thermal performance of an elastomer subjected to radiant heating

    Science.gov (United States)

    Hender, D. R.; Cross, C. R.

    1981-06-01

    This paper describes a test technique and modeling procedure that has been developed to provide an accurate thermal response model for a one-dimensional subliming ablation analysis code. Thin foil thermocouples are molded into the elastomer at different depths and tests are run at a broad range of radiant heat rates, thereby developing accurate temperature response data. Several test runs are made at a low heat flux to enable verification or adjustment of thermophysical properties measured in the laboratory. The modeling procedure consists of establishing a set of thermal properties and ablation parameters that match the test data over the range of test conditions. An NBR/EPDM blend material was used in the testing and modeling reported in this paper.

  8. Radiant heat transfer network in the simulated protective clothing ; System under high heat flux

    NARCIS (Netherlands)

    Fukazawa, T.; Hartog, E.A. den; Daanen, H.A.M.; Penders-van Elk, N.; Tochihara, Y.; Havenith, G.

    2005-01-01

    A radiant network model was developed for design of the protective clothing system against solar and infrared radiative heat flux. A one-dimensional model was employed in the present study, because the aim of this study was to obtain precise temperature distribution through the system with use of a

  9. Indoor temperatures for calculating room heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei

    2016-01-01

    In this study, a typical office room with a radiant heating system and a mechanical ventilation system was selected as the research subject. Indoor temperature formulas for calculating the room heat loss (including transmission heat loss and ventilation heat loss) and heating capacity of the hybrid...... for calculating ventilation heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems. (C) 2015 Elsevier B.V. All rights reserved....... change rates on the indoor temperatures were performed using the proposed model. When heated surface temperatures and air change rates were from 21.0 to 29.0 degrees C and from 0.5 to 4.0 h-1, the indoor temperatures for calculating the transmission heat loss and ventilation heat loss were between 20...

  10. An experimental investigation devoted to determine heat transfer characteristics in a radiant ceiling heating system

    Science.gov (United States)

    Koca, Aliihsan; Acikgoz, Ozgen; Çebi, Alican; Çetin, Gürsel; Dalkilic, Ahmet Selim; Wongwises, Somchai

    2017-08-01

    Investigations on heated ceiling method can be considered as a new research area in comparison to the common wall heating-cooling and cooled ceiling methods. In this work, heat transfer characteristics of a heated radiant ceiling system was investigated experimentally. There were different configurations for a single room design in order to determine the convective and radiative heat transfer rates. Almost all details on the arrangement of the test chamber, hydraulic circuit and radiant panels, the measurement equipment and experimental method including uncertainty analysis were revealed in detail indicating specific international standards. Total heat transfer amount from the panels were calculated as the sum of radiation to the unheated surfaces, convection to the air, and conduction heat loss from the backside of the panels. Integral expression of the view factors was calculated by means of the numerical evaluations using Matlab code. By means of this experimental chamber, the radiative, convective and total heat-transfer coefficient values along with the heat flux values provided from the ceiling to the unheated surrounding surfaces have been calculated. Moreover, the details of 28 different experimental case study measurements from the experimental chamber including the convective, radiative and total heat flux, and heat output results are given in a Table for other researchers to validate their theoretical models and empirical correlations.

  11. An experimental investigation devoted to determine heat transfer characteristics in a radiant ceiling heating system

    Science.gov (United States)

    Koca, Aliihsan; Acikgoz, Ozgen; Çebi, Alican; Çetin, Gürsel; Dalkilic, Ahmet Selim; Wongwises, Somchai

    2018-02-01

    Investigations on heated ceiling method can be considered as a new research area in comparison to the common wall heating-cooling and cooled ceiling methods. In this work, heat transfer characteristics of a heated radiant ceiling system was investigated experimentally. There were different configurations for a single room design in order to determine the convective and radiative heat transfer rates. Almost all details on the arrangement of the test chamber, hydraulic circuit and radiant panels, the measurement equipment and experimental method including uncertainty analysis were revealed in detail indicating specific international standards. Total heat transfer amount from the panels were calculated as the sum of radiation to the unheated surfaces, convection to the air, and conduction heat loss from the backside of the panels. Integral expression of the view factors was calculated by means of the numerical evaluations using Matlab code. By means of this experimental chamber, the radiative, convective and total heat-transfer coefficient values along with the heat flux values provided from the ceiling to the unheated surrounding surfaces have been calculated. Moreover, the details of 28 different experimental case study measurements from the experimental chamber including the convective, radiative and total heat flux, and heat output results are given in a Table for other researchers to validate their theoretical models and empirical correlations.

  12. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation...

  13. Experimental study on moisture transfer through firefighters' protective fabrics in radiant heat exposures

    Directory of Open Access Journals (Sweden)

    Chen Meng

    2017-01-01

    Full Text Available The effects of absorbed moisture on thermal protective performance of fire-fighters’ clothing materials under radiant heat flux conditions were analyzed in this paper. A thermal protective performance tester and temperature sensor were used to measure the temperature variations for the facecloth side of four kinds of commonly used flame retardant fabrics in several radiant heat exposures, which varied in moisture content. Experimental results showed that, all of the temperature profiles of these four kinds of moistened fabrics under different radiant heat flux conditions presented the same variation trend. The addition of moisture had a positive influence on the thermal protective performance during the constant temperature period when heat radiation time was more than 60 seconds. As the heat radiation time increased beyond 500 seconds, the thermal protective performance of moistened fabrics became worse than that of dried fabrics in general.

  14. Mathematical modeling of radiant heating of a closed rectangular area under conditions of convective heat transfer at the external boundaries

    Directory of Open Access Journals (Sweden)

    Nee Alexander

    2015-01-01

    Full Text Available Mathematical modeling of radiant heating of a closed rectangular area under conditions of convective heat transfer at the external boundaries is passed. The fields of temperature and stream function, illustrating the unsteady nature of the heat transfer were obtained. The extent influence of convective heat transfer at the external boundaries on the circulating flows formation in the gas cavity are shown.

  15. The effect of rowing headgear on forced convective heat loss and radiant heat gain on a thermal manikin headform.

    Science.gov (United States)

    Bogerd, Cornelis P; Brühwiler, Paul A; Heus, Ronald

    2008-05-01

    Both radiant and forced convective heat flow were measured for a prototype rowing headgear and white and black cotton caps. The measurements were performed on a thermal manikin headform at a wind speed of 4.0 m . s(-1) (s = 0.1) in a climate chamber at 22.0 degrees C (s = 0.05), with and without radiant heat flow from a heat lamp, coming from either directly above (90 degrees ) or from above at an angle of 55 degrees . The effects of hair were studied by repeating selected measurements with a wig. All headgear reduced the radiant heat gain compared with the nude headform: about 80% for the caps and 95% for the prototype rowing headgear (P headgear (9%) (P headgear, showing that forced convective heat loss is the dominant heat transfer parameter under the chosen conditions. The results of the headgear - wig combinations were qualitatively similar, with lower absolute heat transfer.

  16. Calculation codes for radiant heat transfers; Les codes de calcul de rayonnement thermique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This document reports on 12 papers about computerized simulation and modeling of radiant heat transfers and fluid flows in various industrial and domestic situations: space heating, metal industry (furnaces, boilers..), aerospace industry (turbojet engines, combustion chambers) etc.. This workshop was organized by the ``radiation`` section of the French society of thermal engineers. (J.S.)

  17. The efficacy of radiant heat controls on workers' heat stress around the blast furnace of a steel industry.

    Science.gov (United States)

    Giahi, Omid; Darvishi, Ebrahim; Aliabadi, Mohsen; Khoubi, Jamshid

    2015-01-01

    Workers' exposure to excessive heat in molten industries is mainly due to radiant heat from hot sources. The aim of this study was to evaluate the efficacy of radiant heat controls on workers heat stress around a typical blast furnace. Two main interventions were applied for reducing radiant heat around the blast furnace of a steel industry located in western Iran. These included using a heat absorbing system in the furnace body and installing reflective aluminum barrier in the main workstation. Heat stress indexes were measured before and after each intervention using the digital WBGT-meter. The results showed MRT and WBGT indexes decreased by 20 °C and 3.9 °C, respectively after using heat absorbing system and also decreased by 18.6 °C and 2.5 °C, respectively after installing a reflective barrier. These indexes decrease by 26.5 °C and 5.2 °C, respectively due to the simultaneous application of the two interventions which were statistically significant (p heat control at source can be considered as a first solution for reducing radiant heat of blast furnaces. However, the simultaneous application of interventions could noticeably reduce worker heat stress. The results provide reliable information in order to implement the effective heat controls in typical hot steel industries.

  18. Assessing neonatal heat balance and physiological strain in newborn infants nursed under radiant warmers in intensive care with fentanyl sedation.

    Science.gov (United States)

    Molgat-Seon, Yannick; Daboval, Thierry; Chou, Shirley; Jay, Ollie

    2014-12-01

    To assess heat balance status of newborn infants nursed under radiant warmers (RWs) during intensive care. Heat balance, thermal status and primary indicators of physiological strain were concurrently measured in 14 newborns nursed under RWs for 105 min. Metabolic heat production (M), evaporative heat loss (E), convective (C) and conductive heat flow (K), rectal temperature (T re) and mean skin temperatures (T sk) were measured continuously. The rate of radiant heat required for heat balance (R req) and the rate of radiant heat provided (R prov) were derived. The rate of body heat storage (S) was calculated using a two-compartment model of 'core' (T re) and 'shell' (T sk) temperatures. Mean M, E, C and K were 10.5 ± 2.7 W, 5.8 ± 1.1 W, 6.2 ± 0.8 W and 0.1 ± 0.1 W, respectively. Mean R prov (1.7 ± 2.6 W) and R req (1.7 ± 2.7 W) were similar (p > 0.05). However, while the resultant mean change in body heat content after 105 min was negligible (-0.1 ± 3.7 kJ), acute time-dependent changes in S were evidenced by a mean positive heat storage component of +6.4 ± 2.6 kJ and a mean negative heat storage component of -6.5 ± 3.7 kJ. Accordingly, large fluctuations in both T re and T sk occurred that were actively induced by changes in RW output. Nonetheless, no active physiological responses (heart rate, breathing frequency and mean arterial pressure) to these bouts of heating and cooling were observed. RWs maintain net heat balance over a prolonged period, but actively induce acute bouts of heat imbalance that cause rapid changes in T re and T sk. Transient bouts of heat storage do not exacerbate physiological strain, but could in the longer term.

  19. Solar radiation, phytoplankton pigments and the radiant heating of the equatorial Pacific warm pool

    Science.gov (United States)

    Siegel, David A.; Ohlmann, J. Carter; Washburn, Libe; Bidigare, Robert R.; Nosse, Craig T.; Fields, Erik; Zhou, Yimei

    1995-01-01

    Recent optical, physical, and biological oceanographic observations are used to assess the magnitude and variability of the penetrating flux of solar radiation through the mixed layer of the warm water pool (WWP) of the western equatorial Pacific Ocean. Typical values for the penetrative solar flux at the climatological mean mixed layer depth for the WWP (30 m) are approx. 23 W/sq m and are a large fraction of the climatological mean net air-sea heat flux (approx. 40 W/sq m). The penetrating solar flux can vary significantly on synoptic timescales. Following a sustained westerly wind burst in situ solar fluxes were reduced in response to a near tripling of mixed layer phytoplankton pigment concentrations. This results in a reduction in the penetrative flux at depth (5.6 W/sq m at 30 m) and corresponds to a biogeochemically mediated increase in the mixed layer radiant heating rate of 0.13 C per month. These observations demonstrate a significant role of biogeochemical processes on WWP thermal climate. We speculate that this biogeochemically mediated feedback process may play an important role in enhancing the rate at which the WWP climate system returns to normal conditions following a westerly wind burst event.

  20. Finite element analysis of radiant heating systems based on gas-fired infrared heat emitters

    Directory of Open Access Journals (Sweden)

    Ermolaev Anton N.

    2017-01-01

    Full Text Available The article presents a finite element model for simulating a gas-fired IR radiation system. Simulation of gaseous combustion and discrete ordinates radiation model were used to solve a number of heat-transfer problems in ventilated rooms with radiant heating. We used Ansys Multiphysics software and Fluent CFD solver for implementing finite element analysis. To solve differential equations of heating and gas dynamics, the following boundary conditions were considered. Dry methane was used as the fuel and air with 21% of oxygen, as oxidizer. Fuel consumption was 0.5 m3/hour; the gas pressure before the nozzle was 1270 Pa. The air–fuel ratio was 9.996.

  1. Numerical investigation on the convective heat transfer in a spiral coil with radiant heating

    Directory of Open Access Journals (Sweden)

    Đorđević Milan Lj.

    2016-01-01

    Full Text Available The objective of this study was to numerically investigate the heat transfer in spiral coil tube in the laminar, transitional, and turbulent flow regimes. The Archimedean spiral coil was exposed to radiant heating and should represent heat absorber of parabolic dish solar concentrator. Specific boundary conditions represent the uniqueness of this study, since the heat flux upon the tube external surfaces varies not only in the circumferential direction, but also in the axial direction. The curvature ratio of spiral coil varies from 0.029 at the flow inlet to 0.234 at the flow outlet, while the heat transfer fluid is water. The 3-D steady-state transport equations were solved using the Reynolds stress turbulence model. Results showed that secondary flows strongly affect the flow and that the heat transfer is strongly asymmetric, with higher values near the outer wall of spiral. Although overall turbulence levels were lower than in a straight pipe, heat transfer rates were larger due to the curvature-induced modifications of the mean flow and temperature fields. [Projekat Ministarstva nauke Republike Srbije, br. 42006

  2. Thermal Performance Analysis of Reinforced Concrete Floor Structure with Radiant Floor Heating System in Apartment Housing

    Directory of Open Access Journals (Sweden)

    Young-Sun Jeong

    2015-01-01

    Full Text Available The use of the resilient materials in the radiant floor heating systems of reinforced concrete floor in apartment housing is closely related to the reduction of the floor impact sound and the heating energy loss. This study examined the thermal conductivity of expanded polystyrene (EPS foam used for the resilient material in South Korea and analysed the thermal transfer of reinforced concrete floor structure according to the thermal conductivity of the resilient materials. 82 EPS specimens were used to measure the thermal conductivity. The measured apparent density of EPS resilient materials ranged between 9.5 and 63.0 kg/m3, and the thermal conductivity ranged between 0.030 and 0.046 W/(m·K. As the density of resilient materials made of expanded polystyrene foam increases, the thermal conductivity tends to proportionately decrease. To set up reasonable thermal insulation requirements for radiant heating floor systems, the thermal properties of floor structure according to thermal insulation materials must be determined. Heat transfer simulations were performed to analyze the surface temperature, heat loss, and heat flow of floor structure with radiant heating system. As the thermal conductivity of EPS resilient material increased 1.6 times, the heat loss was of 3.4% increase.

  3. Study of heating performance of radiant ceiling heating system and its impact on workers thermal comfort level of workers in typical industrial work shops

    Directory of Open Access Journals (Sweden)

    M. Aliabadi

    2013-08-01

    .Conclusion: Due to large space of these industrial units, producing appropriate heating by convection mechanism is too difficult and expensive. The results confirmed that if radiant heating system applied based on scientific design principles they could be effective in promotion of thermal comfort due to heating surrounding surface by radiant and also reducing fuel consumption.

  4. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    with displacement ventilation. Vertical air temperature distribution was more uniform for floor heating than for warm air heating, but there was no significant difference in thermal perception between the two mixing ventilation systems. For the summer conditions the subjects voted warmer than predicted by the PMV...... supplying warm air space heating or by a combination of radiant floor heating and mixing ventilation system. Next two test setups simulated an office room with two occupants during summer, ventilated and cooled by a single displacement ventilation system or by a radiant floor cooling combined...... and about one third preferred more air movement. No significant difference in thermal perception between the two displacement ventilation systems was found....

  5. A new simplified model to calculate surface temperature and heat transfer of radiant floor heating and cooling systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Olesen, Bjarne W.

    2015-01-01

    In this paper, a new simplified model to calculate surface temperature and heat transfer of radiant floor heating and cooling system was proposed and established using the conduction shape factor. Measured data from references were used to validate the proposed model. The results showed...... that the maximum differences between the calculated surface temperature and heat transfer using the proposed model and the measured data were 0.8 ºC and 8.1 W/m2 for radiant floor heating system when average water temperature between 40 ºC and 60 ºC. For the corresponding values were 0.3 ºC and 2.0 W/m2...... for radiant floor cooling systems when average water temperature between 10 ºC and 20 ºC. Numerically simulated data in this study were also used to validate the proposed model. The results showed that the surface temperature and heat transfer of radiant floor calculated by the proposed model agreed very well...

  6. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    Sixteen subjects evaluated the indoor environment in four experiments with different combinations of ventilation and radiant heating/cooling systems. Two test setups simulated a room in a low energy building with a single occupant during winter. The room was equipped either by a ventilation system...... with displacement ventilation. Vertical air temperature distribution was more uniform for floor heating than for warm air heating, but there was no significant difference in thermal perception between the two mixing ventilation systems. For the summer conditions the subjects voted warmer than predicted by the PMV...

  7. Effect of radiant heat and ultrasound on fluoride release and surface hardness of glass ionomer cements.

    Science.gov (United States)

    Tolidis, Kosmas; Dionysopoulos, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos

    2016-11-02

    The purpose of this investigation was to evaluate the influence of radiant heat and ultrasound on fluoride release and surface hardness of 3 glass ionomer cements (GICs). There were 3 experimental groups for each GIC; in group 1, the specimens were left to set without any treatment; in group 2, the specimens were irradiated for 2 minutes using a LED unit; and in group 3, ultrasound was applied using a scaler for 55 seconds on the specimen surface. Fluoride release measurements were performed daily for 7 days and at days 14 and 28. Surface hardness of the tested GICs was determined using Vickers method. The measurements were performed 24 hours and 7 days after mixing. Statistical analysis of the data was made using 1-way ANOVA and Tukey's and Bonferroni post hoc tests (α = 0.05). Radiant heat during setting reduced the fluoride release and increased the surface hardness of GICs (p<0.05). Ultrasonic treatment also reduced the fluoride release and increased the surface hardness (p<0.05) of GICs but in lower extent. Among the GICs there were differences in fluoride release and surface hardness properties depending on their composition (p<0.05). Radiant heat and ultrasonic treatments may be useful methods for GIC restorations in order to achieve faster adequate initial mechanical properties.

  8. Experimental Evaluation of the Thermal Performance of Raised Floor Integrated Radiant Heating Panels

    Directory of Open Access Journals (Sweden)

    Dong-Woo Kim

    2017-10-01

    Full Text Available In this study, we propose a method for the evaluation of the thermal output of radiant heating panels by employing a modification of the currently used method, which is recommended by existing standards, using cooling plates. We aim to overcome the absence in the measurement method of the downward thermal output as well as to address the challenges in the control of the heat transfer resistance of the heat transfer layer, which arise due to the contact resistance between the layers. Using the modified method, we compare the thermal performance of three types of raised floor integrated radiant heating panels that have different filler materials for the bottom insulation of the panel. We show that the most efficient sample panel is the one that is not filled with a material; with an efficiency of 70.1%. In addition, we show that the value of the gradient of the characteristic curve calculated by the existing method ranged between 7.2% to 14.9% larger than that obtained by modified method. This difference is attributed to the heat transfer resistance of the heat transfer layer that is present in the experiments, and has a value in the interval of 0.1096 m 2 K / W to 0.1582 m 2 K / W . This is caused by the contact resistance between the heat transfer layer and other layers, even though the heat transfer resistance of the heat transfer layer used in the experiment is 0.0985 m 2 K / W . The modified method proposed in this study reveals that the experimental results are not influenced by the heat transfer resistance of the heat transfer layer. We also show that our experimental results are reproducible.

  9. Comparison of indoor air distribution and thermal environment for different combinations of radiant heating systems with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2018-01-01

    air distribution and the thermal environment for all combinations of radiant heating systems with mechanical ventilation systems. Therefore, in this article, the indoor air distribution and the thermal environment were comparatively analyzed in a room with floor heating (FH) or ceiling heating (CH...

  10. Radiant heat testing of the H1224A shipping/storage container

    Energy Technology Data Exchange (ETDEWEB)

    Harding, D.C.; Bobbe, J.G.; Stenberg, D.R.; Arviso, M.

    1994-05-01

    H1224A weapons containers have been used for years by the Departments of Energy and Defense to transport and store W78 warhead midsections. Although designed to protect the midsections only from low-energy impacts, a recent transportation risk assessment effort has identified a need to evaluate the container`s ability to protect weapons in more severe accident environments. Four radiant heat tests were performed: two each on an H1224A container (with a Mk12a Mod 6c mass mock-up midsection inside) and two on a low-cost simulated H1224A container (with a hollow Mk12 aeroshell midsections inside). For each unit tested, temperatures were recorded at numerous points throughout the container and midsection during a 4-hour 121{degrees}C (250{degrees}F) and 30-minute 1010{degrees}C (1850{degrees}F) radiant environment. Measured peak temperatures experienced by the inner walls of the midsections as a result of exposure to the high-temperature radiant environment ranged from 650{degrees} C to 980{degrees} C (1200{degrees} F to 1800{degrees}F) for the H1224A container and 770 {degrees} to 990 {degrees}C (1420{degrees} F to 1810{degrees}F) for the simulated container. The majority of both containers were completely destroyed during the high-temperature test. Temperature profiles will be used to benchmark analytical models and predict warhead midsection temperatures over a wide range of the thermal accident conditions.

  11. Heat transfer in heated industrial premises with using radiant heating system

    Directory of Open Access Journals (Sweden)

    Nagornova Tatiana A.

    2017-01-01

    Full Text Available The results of mathematical modeling of heat transfer processes in a closed air volume surrounded by enclosing constructions, heated by supplying energy to the upper contour of gas infrared radiators are represented. Regimes of turbulent natural conjugate convection in the region bounded by solid walls are investigated. Two-dimensional nonstationary problem is solved in the framework of the Navier -Stokes equations for gas and thermal conductivity for solid walls. Nonstationary processes of heat propagation in course of time and essential heterogeneity of temperature fields and heat fluxes are established.

  12. Newborns' temperature submitted to radiant heat and to the Top Maternal device at birth

    Directory of Open Access Journals (Sweden)

    Rosemeire Sartori de Albuquerque

    Full Text Available ABSTRACT Objective: to compare the axillar temperatures of newborns that are put immediately after birth in skin-to-skin contact under the Top Maternal device, as compared to those in a radiant heat crib. Methods: comparatives observational study of the case-control type about temperature of 60 babies born at the Obstetric Center and Normal Delivery Center of a public hospital of the municipality of Sao Paulo, being them: 29 receiving assistance in heated crib and 31 in skin-to skin contact, shielded by a cotton tissue placed on mother's thorax, called Top Maternal. Results: the temperature of the babies of the skin-to-skin contact group presented higher values in a larger share of the time measures verified, as compared to those that were placed in radiant heat crib, independently from the place of birth. Differences between the two groups were not statistically significant. Conclusion: the study contributes to generate new knowledge, supporting the idea of keeping babies with their mothers immediately after birth protected with the Maternal Top, without harming their wellbeing, as it keeps the axillar temperature in recommendable levels.

  13. Energy flow and thermal comfort in buildings: Comparison of radiant and air-based heating & cooling systems

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme

    is based on both radiation and convection. This thesis focuses on characterizing the heat transfer from the terminal towards the space and on the parameters influencing the effectiveness of terminals. Therefore the comfort conditions and energy consumption of four types of terminals (active chilled beam...... the cooling need of the radiant wall compared to the active chilled beam. These conclusions are valid for multi-storey and/or highly insulated buildings (R > 5 m2.K/W). In case of single-storey building with a low level of insulation, the effectiveness of radiant terminals is lower due to the larger back...... losses, and an air-based terminal might be more energy-efficient than a radiant terminal (in terms of delivered energy). Regarding comfort, a similar global level has been observed for the radiant and air-based terminals in both numerical and experimental investigations. But the different terminals did...

  14. Radiant heat transfers in turbojet engines. Two applications, three levels of modeling; Transferts radiatifs dans les foyers de turboreacteurs. Deux applications, trois niveaux de modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, J.L.; Desaulty, M. [SNECMA, Centre de Villaroche, 77 - Moissy-Cramayel (France); Taine, J. [Ecole Centrale de Paris, Laboratoire EM2C. CNRS, 92 - Chatenay-Malabry (France)

    1996-12-31

    Several applications linked with the dimensioning of turbojet engines require the use of modeling of radiant heat transfers. Two different applications are presented in this study: the modeling of heat transfers in the main combustion chamber, and modeling of the infrared signature of the post-combustion chamber of a military engine. In the first application, two types of radiant heat transfer modeling are presented: a global modeling based on empirical considerations and used in rapid pre-dimensioning methods, and a modeling based on a grey gases concept and combined to a ray shooting type technique allowing the determination of local radiant heat flux values. In the second application, a specific modeling of the radiant heat flux is used in the framework of a ray shooting method. Each model represents a different level of successive approximations of the radiant heat transfer adapted to flow specificities and to the performance requested. (J.S.) 16 refs.

  15. Effect of radiant heat at the birth site in farrowing crates on hypothermia and behaviour in neonatal piglets

    DEFF Research Database (Denmark)

    Andersen, Heidi Mai-Lis; Pedersen, Lene Juul

    2016-01-01

    providing radiant heat at the birth site to new-born piglets in pens with crated sows reduced hypothermia, time to first milk intake and growth of the piglets during the 1st week. Second parity Danish Landrace×Yorkshire sows (n=36) were randomly divided into two groups: Control (CG) and heat (HG...... udder (Phypothermia in new-born piglets and indicate that providing heat during the first half hour after birth is important....

  16. Thermal Testing of Ablators in the NASA Johnson Space Center Radiant Heat Test Facility

    Science.gov (United States)

    Del Papa, Steven; Milhoan, Jim; Remark, Brian; Suess, Leonard

    2016-01-01

    A spacecraft's thermal protection system (TPS) is required to survive the harsh environment experienced during reentry. Accurate thermal modeling of the TPS is required to since uncertainties in the thermal response result in higher design margins and an increase in mass. The Radiant Heat Test Facility (RHTF) located at the NASA Johnson Space Center (JSC) replicates the reentry temperatures and pressures on system level full scale TPS test models for the validation of thermal math models. Reusable TPS, i.e. tile or reinforced carbon-carbon (RCC), have been the primary materials tested in the past. However, current capsule designs for MPCV and commercial programs have required the use of an ablator TPS. The RHTF has successfully completed a pathfinder program on avcoat ablator material to demonstrate the feasibility of ablator testing. The test results and corresponding ablation analysis results are presented in this paper.

  17. Two-Dimensional Problem of Turbulent Natural Convection in a Semi-Open Cavity with Radiant Heating of Internal Boundaries

    Directory of Open Access Journals (Sweden)

    Nee Alexander

    2016-01-01

    Full Text Available Mathematical modelling of turbulent natural convection in a semi-open cavity with a heat-conducting walls of finite thickness with radiant heating of internal boundaries was performed. Two-dimensional problem of the conjugate heat transfer was solved by means of the finite difference method. Scale influence of open boundaries and radiant heating of the gas – wall interfaces on the formation of differential and integral heat transfer characteristics was established. An increase in the dimensionless time (τ led to displacement of extremum temperatures in the typical cross section (Y = 0.5 to an open vertical boundary. The average Nusselt number monotonically increased at the gas – a wall interfaces in a range of 400<τ<1200.

  18. Effect of supply air temperature on air distribution in a room with radiant heating and mechanical ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Fang, Lei

    2017-01-01

    The present study focused on the effect of supply air temperature on air distribution in a room with floor heating (FH) or ceiling heating (CH) and mixing ventilation (MV) or displacement ventilation (DV). The vertical distribution of air temperature and velocity in the occupied zone and the hori......The present study focused on the effect of supply air temperature on air distribution in a room with floor heating (FH) or ceiling heating (CH) and mixing ventilation (MV) or displacement ventilation (DV). The vertical distribution of air temperature and velocity in the occupied zone...... are relevant to the design and control of the hybrid systems with radiant heating systems and mechanical ventilation systems....

  19. Newborns' temperature submitted to radiant heat and to the Top Maternal device at birth.

    Science.gov (United States)

    Albuquerque, Rosemeire Sartori de; Mariani, Corintio; Bersusa, Ana Aparecida Sanches; Dias, Vanessa Macedo; Silva, Maria Izabel Mota da

    2016-08-08

    to compare the axillar temperatures of newborns that are put immediately after birth in skin-to-skin contact under the Top Maternal device, as compared to those in a radiant heat crib. comparatives observational study of the case-control type about temperature of 60 babies born at the Obstetric Center and Normal Delivery Center of a public hospital of the municipality of Sao Paulo, being them: 29 receiving assistance in heated crib and 31 in skin-to skin contact, shielded by a cotton tissue placed on mother's thorax, called Top Maternal. the temperature of the babies of the skin-to-skin contact group presented higher values in a larger share of the time measures verified, as compared to those that were placed in radiant heat crib, independently from the place of birth. Differences between the two groups were not statistically significant. the study contributes to generate new knowledge, supporting the idea of keeping babies with their mothers immediately after birth protected with the Maternal Top, without harming their wellbeing, as it keeps the axillar temperature in recommendable levels. comparar a temperatura axilar dos recém-nascidos acomodados - imediatamente após o nascimento - em contato pele a pele, sob o Top Maternal, em berço de calor radiante. estudo comparativo observacional do tipo Caso-Controle sobre a temperatura de 60 bebês nascidos no Centro Obstétrico e Centro de Parto Normal de um hospital público do município de São Paulo, sendo: 29 assistidos em berço aquecido e 31 em contato pele a pele, protegidos por uma malha de algodão colocada sobre o tórax da mãe, denominada Top Maternal. a temperatura dos bebês do grupo de contato pele a pele teve maior valor na maioria dos tempos verificados comparada à dos que foram colocados em berço de calor radiante, independentemente do local de nascimento. A diferença entre os grupos não foi estatisticamente significante. o estudo contribui com a geração de um novo conhecimento que sustenta a

  20. Combustion characteristics in oil-vaporizing sustained by radiant heat reflux enhanced with higher porous ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Takuya Fuse; Yugo Araki; Noriyuki Kobayashi; Masanobu Hasatani [Nagoya University, Nagoya (Japan). Department of Energy Engineering and Science, Graduate School of Engineering

    2003-07-01

    Liquid vaporizing combustion in porous ceramic burner has fine flame stability and characteristic of low emission. On the other hand, vaporization control has been seldom mentioned. In this work, kerosene vaporizing type combustor equipped with a porous ceramic plate, which has the porosity of 85%, is developed in order to enhance a rate of vaporization of the liquid fuel. The stability of combustion and NOx emission characteristics were investigated in fuel vaporizing ceramic combustion. The plate burner is made of Al{sub 2}O{sub 3} ceramic which has an optical-thickness of 0.54. The optically thin ceramics improved flame stability and enhances more fuel vaporization rate than optically thick ceramics. The thermal radiation energy from flame and the furnace walls can penetrate easily through the large pore of the ceramic plate. It is found possible to dispense the electric power for the fuel vaporization and the stable combustion is self-sustained by enhancement of vaporization, where the reflux rate of radiant heat was no less than 2% of the heating value. 19 refs., 10 figs., 1 tab.

  1. Experimental study including subjective evaluations of mixing and displacement ventilation combined with radiant floor heating/cooling system

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2013-01-01

    heating or by a combination of radiant floor heating and mixing ventilation system. The vertical air temperature distribution was more uniform for floor heating. The discomfort due to cold feet/lower legs was higher for warm air heating, but no significant difference in thermal perceptions between the two...... lower floor temperature, warmer supply air, and less homogeneous vertical temperature profile, but it did not result in thermal discomfort on feet/lower legs or discomfort due to a vertical air temperature difference higher than for a displacement ventilation system alone, where the floor temperature...

  2. Mapping temperature and radiant geothermal heat flux anomalies in the Yellowstone geothermal system using ASTER thermal infrared data

    Science.gov (United States)

    Vaughan, R. Greg; Lowenstern, Jacob B.; Keszthelyi, Laszlo P.; Jaworowski, Cheryl; Heasler, Henry

    2012-01-01

    The purpose of this work was to use satellite-based thermal infrared (TIR) remote sensing data to measure, map, and monitor geothermal activity within the Yellowstone geothermal area to help meet the missions of both the U.S. Geological Survey Yellowstone Volcano Observatory and the Yellowstone National Park Geology Program. Specifically, the goals were to: 1) address the challenges of remotely characterizing the spatially and temporally dynamic thermal features in Yellowstone by using nighttime TIR data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and 2) estimate the temperature, geothermal radiant emittance, and radiant geothermal heat flux (GHF) for Yellowstone’s thermal areas (both Park wide and for individual thermal areas). ASTER TIR data (90-m pixels) acquired at night during January and February, 2010, were used to estimate surface temperature, radiant emittance, and radiant GHF from all of Yellowstone’s thermal features, produce thermal anomaly maps, and update field-based maps of thermal areas. A background subtraction technique was used to isolate the geothermal component of TIR radiance from thermal radiance due to insolation. A lower limit for the Yellowstone’s total radiant GHF was established at ~2.0 GW, which is ~30-45% of the heat flux estimated through geochemical (Cl-flux) methods. Additionally, about 5 km2 was added to the geodatabase of mapped thermal areas. This work provides a framework for future satellite-based thermal monitoring at Yellowstone as well as exploration of other volcanic / geothermal systems on a global scale.

  3. Mathematical Modeling of Radiant Heat Transfer in Mirror Systems Considering Deep Reflecting Surface Defects

    Directory of Open Access Journals (Sweden)

    V. V. Leonov

    2014-01-01

    Full Text Available When designing large-sized mirror concentrating systems (MCS for high-temperature solar power plants, one must have at disposal reasonably reliable and economical methods and tools, making it possible to analyze its characteristics, to predict them depending on the operation conditions and accordingly to choose the most suitable system for the solution of particular task.Experimental determination of MCS characteristics requires complicated and expensive experimentation, having significant limitations on interpretation of the results, as well as limitations imposed due to the size of the structure. Therefore it is of particular interest to develop a mathematical model capable of estimating power characteristics of MCS considering the influence of operating conditions, design features, roughness and other surface defects.For efficient solution of the tasks the model must ensure simulation of solar radiant flux as well as simulation of geometrical and optical characteristics of reflection surface and their interaction. In this connection a statistical mathematical model of radiation heat exchange based on use of Monte Carlo methods and Finite Element Method was developed and realized in the software complex, making it possible to determine main characteristics of the MCS.In this paper the main attention is given to definition of MCS radiation characteristics with account for deep reflecting surface defects (cavities, craters. Deep cavities are not typical for MCS, but their occurrence is possible during operation as a result of erosion or any physical damage. For example, for space technology it is primarily micrometeorite erosion.

  4. Heat transfers in porous media. Conduction, convection, radiant transfer; Transferts de chaleur dans les milieux poreux. Conduction, convection, rayonnement

    Energy Technology Data Exchange (ETDEWEB)

    Bories, S.; Mojtabi, A.; Prat, M.; Quintard, M. [Institut de Mecanique des Fluides de Toulouse, 31 (France)

    2008-10-15

    Multiple physico-chemical and transport phenomena take place in porous media. The study of these phenomena requires the knowledge of fluid storage, transfer and mechanical properties of these media. Like all polyphasic heterogenous systems, these properties depend on the morphology of the matrix and of the phenomena interacting in the different phases. This makes the heat transfers in porous media a particularly huge field of researches. This article makes a synthesis of these researches. Content: 1 - classification and characterization of porous media; 2 - modeling of transfer phenomena; 3 - heat transfer by conduction: concept of equivalent thermal conductivity (ETC), modeling of conduction heat transfer, ETC determination; 4 - heat transfer by convection: modeling of convection heat transfer, natural convection (in confined media, along surfaces or impermeable bodies immersed in a saturated porous medium), forced and mixed convection; 5 - radiant heat transfer: energy status equation, approximate solutions of the radiant transfer equation, use of the approximate solutions: case of fibrous insulating materials; 6 - conclusion. (J.S.)

  5. Heat transfer in hybrid fibre reinforced concrete-steel composite column exposed to a gas-fired radiant heater

    Science.gov (United States)

    Štefan, R.; Procházka, J.; Novák, J.; Fládr, J.; Wald, F.; Kohoutková, A.; Scheinherrová, L.; Čáchová, M.

    2017-09-01

    In the paper, a gas-fired radiant heater system for testing of structural elements and materials at elevated temperatures is described. The applicability of the system is illustrated on an example of the heat transfer experiment on a hybrid fibre reinforced concrete-steel composite column specimen. The results obtained during the test are closely analysed by common data visualization techniques. The experiment is simulated by a mathematical model of heat transfer, assuming the material data of the concrete determined by in-house measurements. The measured and calculated data are compared and discussed.

  6. Microwave assisted radiant heating effect on the crystallization of SnO2 thin films prepared by spin-coating

    Science.gov (United States)

    Gome, Anil; Reddy, V. Raghavendra; Ganesan, V.; Gupta, Ajay

    2017-05-01

    Crystallization study of SnO2 thin films prepared by spin-coating method are reported when subjected to microwave assisted radiant heating (MARH). The as-prepared and annealed films are studied using atomic force microscopy, grazing incidence x-ray diffraction and conversion electron Mossbauer spectroscopy measurements. Sn4+ state in all films is confirmed from 119Sn Mossbauer spectroscopy measurements. The results indicate that one can employ microwave heating to prepare SnO2 thin films with controlled surface morphology which might be useful for various practical applications.

  7. Numerical Analysis of Three-Dimensional Natural Convection in a Closed Rectangular Cavity Under Conditions of Radiant Heating and Conjugate Heat Exchange

    Directory of Open Access Journals (Sweden)

    Nee Alexander E.

    2017-01-01

    Full Text Available The numerical simulation results of three-dimensional natural convection in a closed cavity were presented under conditions of the bottom horizontal solid-fluid interface radiant heating and conjugate heat exchange. Conservation equations of mass, momentum, and energy were formulated in terms of vorticity vector – vector potential – temperature dimensionless variables and solved by means of the finite difference method. It was found that the heat transfer process under study had a significant unsteady nature. According to the results of conjugate heat exchange integral analysis, it was shown that similar trends of mean Nusselt numbers versus dimensionless time were formed for both two and three dimensional problem formulations.

  8. Radiant heat evaluation of concrete: a study of the erosion of concrete due to surface heating

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.Y.

    1978-01-01

    Experiments were carried out to investigate the erosion of concrete under high surface heat flux in connection with the core-melt/concrete interaction studies. The dominate erosion mechanism was found to be melting at the surface accompanied by chemical decomposition of the concrete beneath the melt-solid interface. The erosion process reaches a steady state after an initial transient. The steady state is characterized by an essentially constant erosion rate at the surface and a nonvarying (with respect to the moving melt interface) temperature distribution within the concrete. For the range of incident heat flux 64 W/cm/sup 2/ to 118 W/cm/sup 2/, the corresponding steady state erosion rate varies from approximately 8 cm/hr to 23 cm/hr. A simple ablation/melting model is proposed for the erosion process. The model was found to be able to correlate all temperature responses at various depths from all tests at large times and for temperatures above approximately 250/sup 0/C.

  9. Thermal Comfort and Energy Consumption Using Different Radiant Heating/Cooling Systems in a Modern Office Building

    Science.gov (United States)

    Nemethova, Ema; Stutterecker, Werner; Schoberer, Thomas

    2017-06-01

    The aim of the study is to evaluate the potential of enhancing thermal comfort and energy consumption created by three different radiant systems in the newly-built Energetikum office building. A representative office, Simulation room 1/1, was selected from 6 areas equipped with portable sensor groups for the indoor environment monitoring. The presented data obtained from 3 reference weeks; the heating, transition and cooling periods indicate overheating, particularly during the heating and transition period. The values of the indoor air temperature during the heating and transition period could not meet the normative criteria according to standard EN 15251:2007 (cat. II.) for 15-30% of the time intervals evaluated. Consequently, a simulation model of the selected office was created and points to the possibilities of improving the control system, which can lead to an elimination of the problem with overheating. Three different radiant systems - floor heating/ cooling, a thermally active ceiling, and a near-surface thermally active ceiling were implemented in the model. A comparison of their effects on thermal comfort and energy consumption is presented in the paper.

  10. Integrated thermal infrared imaging and Structure-from-Motion photogrametry to map apparent temperature and radiant hydrothermal heat flux at Mammoth Mountain, CA USA

    Science.gov (United States)

    Lewis, Aaron; George Hilley,; Lewicki, Jennifer L.

    2015-01-01

    This work presents a method to create high-resolution (cm-scale) orthorectified and georeferenced maps of apparent surface temperature and radiant hydrothermal heat flux and estimate the radiant hydrothermal heat emission rate from a study area. A ground-based thermal infrared (TIR) camera was used to collect (1) a set of overlapping and offset visible imagery around the study area during the daytime and (2) time series of co-located visible and TIR imagery at one or more sites within the study area from pre-dawn to daytime. Daytime visible imagery was processed using the Structure-from-Motion photogrammetric method to create a digital elevation model onto which pre-dawn TIR imagery was orthorectified and georeferenced. Three-dimensional maps of apparent surface temperature and radiant hydrothermal heat flux were then visualized and analyzed from various computer platforms (e.g., Google Earth, ArcGIS). We demonstrate this method at the Mammoth Mountain fumarole area on Mammoth Mountain, CA. Time-averaged apparent surface temperatures and radiant hydrothermal heat fluxes were observed up to 73.7 oC and 450 W m-2, respectively, while the estimated radiant hydrothermal heat emission rate from the area was 1.54 kW. Results should provide a basis for monitoring potential volcanic unrest and mitigating hydrothermal heat-related hazards on the volcano.

  11. Estimation of Surface Temperature and Heat Flux by Inverse Heat Transfer Methods Using Internal Temperatures Measured While Radiantly Heating a Carbon/Carbon Specimen up to 1920 F

    Science.gov (United States)

    Pizzo, Michelle; Daryabeigi, Kamran; Glass, David

    2015-01-01

    The ability to solve the heat conduction equation is needed when designing materials to be used on vehicles exposed to extremely high temperatures; e.g. vehicles used for atmospheric entry or hypersonic flight. When using test and flight data, computational methods such as finite difference schemes may be used to solve for both the direct heat conduction problem, i.e., solving between internal temperature measurements, and the inverse heat conduction problem, i.e., using the direct solution to march forward in space to the surface of the material to estimate both surface temperature and heat flux. The completed research first discusses the methods used in developing a computational code to solve both the direct and inverse heat transfer problems using one dimensional, centered, implicit finite volume schemes and one dimensional, centered, explicit space marching techniques. The developed code assumed the boundary conditions to be specified time varying temperatures and also considered temperature dependent thermal properties. The completed research then discusses the results of analyzing temperature data measured while radiantly heating a carbon/carbon specimen up to 1920 F. The temperature was measured using thermocouple (TC) plugs (small carbon/carbon material specimens) with four embedded TC plugs inserted into the larger carbon/carbon specimen. The purpose of analyzing the test data was to estimate the surface heat flux and temperature values from the internal temperature measurements using direct and inverse heat transfer methods, thus aiding in the thermal and structural design and analysis of high temperature vehicles.

  12. Transient Heat Transfer in Radiant Floors: A Comparative Analysis between the Lumped Capacitance Method and Infrared Thermography Measurements

    Directory of Open Access Journals (Sweden)

    Giorgio Baldinelli

    2016-07-01

    Full Text Available The paper presents a simplified mathematical model to describe the transient heat transfer of a radiant floor heating system. A purpose-built test room has been realized to investigate the actual thermal response of a concrete radiant floor in unsteady-state conditions. Beyond the temperature sensors needed for the standard thermal analysis of the heat transfer inside the chamber, the floor temperature was retrieved by means of an infrared thermography camera, in order to validate more precisely the proposed analytical model. The infrared thermography analysis gives interesting information on the floor temperature distribution during the transient, highlighting the pipes’ layout and, if present, inhomogeneous floor zones. The thermal images have been elaborated in order to set and tune the colour map. A portion of the image has been defined for measuring the surface floor temperatures with a previous evaluation of the parameters dealing with the thermographic technique, in order to perform the quantitative survey. The comparison results show that the calculated air and floor temperatures substantially agree with the temperatures measured by infrared thermography and thermocouples, provided that the boundary conditions obtained by the field measurements are strictly reproduced in the lumped capacitance mathematical model. The difference between the two approaches results in values lower than 4 °C during the entire monitoring period: a satisfactory outcome, considering the approximations of the analytical method. The proposed model and its infrared thermography measurements validation represent a useful tool to understand at first sight the floor radiant panels behaviour in the start-up and switch off period, at the aim of gather useful information for the difficult task of their regulation.

  13. The effects of mixing air distribution and heat load arrangement on the performance of ceiling radiant panels under cooling mode of operation

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Kosonen, Risto; Melikov, Arsen Krikor

    2016-01-01

    arrangement and air distribution generated in a room by linear slot diffuser, radial multi-nozzle diffuser and radial swirl induction unit on the cooling power of radiant panels was compared. The impact on the thermal environment was also studied. Measurements were carried out without and with supply air...... 5% to 17% depending on the air distribution method and the heat load arrangement. The most significant effect of the heat load arrangement occured when heat loads are located unevenly and their convection flow turns or weakens the supply air jet flushing the radiant panels....

  14. Some effects of 8-12 micron radiant energy transfer on the mass and heat budgets of cloud droplets

    Science.gov (United States)

    Barkstrom, B. R.

    1978-01-01

    In standard treatments of the mass and energy budget of cloud droplets, radiant energy transfer is neglected on the grounds that the temperature difference between the droplet and its surroundings is small. This paper includes the effect of radiant heating and cooling of droplets by using the Eddington approximation for the solution of the radiative transfer equation. Although the calculation assumes that the cloud is isothermal and has a constant size spectrum with altitude, the heating or cooling of droplets by radiation changes the growth rate of the droplets very significantly. At the top of a cloud with a base at 2500 m and a top at 3000 m, a droplet will grow from 9.5 to 10.5 microns in about 4 min, assuming a supersaturation ratio of 1.0013. Such a growth rate is more than 20 times the growth rate for condensation alone, and may be expected to have a significant impact on estimates of precipitation formation as well as on droplet spectrum calculations.

  15. Heat transfer characteristics of a porous radiant burner under the influence of a 2-D radiation field

    Energy Technology Data Exchange (ETDEWEB)

    Talukdar, Prabal; Mishra, S.C. E-mail: scm_iitg@yahoo.com; Trimis, D.; Durst, F

    2004-04-01

    This paper deals with the heat transfer analysis of a 2-D rectangular porous radiant burner. Combustion in the porous medium is modelled as a spatially dependent heat generation zone. The gas and the solid phases are considered in non-local thermal equilibrium, and separate energy equations are used for the two phases. The solid phase is assumed to be absorbing, emitting and scattering, while the gas phase is considered transparent to radiation. The radiative part of the energy equation is solved using the collapsed dimension method. The alternating direction implicit scheme is used to solve the transient 2-D energy equations. Effects of various parameters on the performance of the burner are studied.

  16. Kinetics of fluoride ion release from dental restorative glass ionomer cements: the influence of ultrasound, radiant heat and glass composition.

    Science.gov (United States)

    Thanjal, N K; Billington, R W; Shahid, S; Luo, J; Hill, R G; Pearson, G J

    2010-02-01

    To compare the effect of ultrasonic setting with self curing on fluoride release from conventional and experimental dental glass ionomer cements. To compare hand mixed and capsule mixing and the effect of replacing some of the reactive glass with zirconia. In a novel material which advocated using radiant heat to cure it, to compare the effect of this with ultrasound. To evaluate the effect of ultrasound on a glass ionomer with fluoride in the water but not in the glass. 10 samples of each cement were ultrasonically set for 55 s; 10 controls self cured for 6 min. Each was placed in 10 ml of deionised water which was changed at 1, 3, 7, 14, 21, 28 days. The solution fluoride content was measured using a selective ion electrode. All ultrasound samples released more fluoride than the controls. Release patterns were similar; after a few days, cumulative fluoride was linear with respect to t(1/2). Slope and intercept of linear regression plots increased with ultrasound. With radiant heat the cement released less fluoride than controls. The effect of ultrasound on cement with F in water increased only slope not intercept. Zirconia addition enhances fluoride release although the cement fluorine content is reduced. Comparison of capsule and hand mixing showed no consistent effect on fluoride release. Ultrasound enhances fluoride release from GICs. As heat has an opposite effect the heat from ultrasound is not its only action. The lesser effect on cement with fluoride only in the water indicates that of ultrasound enhances fluoride release from glass.

  17. Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT

    Directory of Open Access Journals (Sweden)

    Susana Lagüela-López

    2015-01-01

    Full Text Available La inspección de suelos radiantes requiere el uso de técnicas no destructivas, tratando de minimizar el impacto de la inspección, así como el tiempo y el coste, además de maximizar la información adquirida de cara al mejor diagnóstico posible. Con este objetivo, la aplicación de termografía infrarroja (IRT y georradar (GPR se propone para la inspección de suelos radiantes con cobertura de diferentes materiales, para evaluar las capacidades y la información adquirible con cada técnica. Los resultados muestran que cada técnica proporciona diferentes tipos de información: estado de las tuberías (IRT, geometría y configuración (GPR; concluyendo que la inspección óptima está formada por la combinación de ambas técnicas.

  18. Finite-elements modeling of radiant heat transfers between mobile surfaces; Modelisation par elements finis de transferts radiatifs entre surfaces mobiles

    Energy Technology Data Exchange (ETDEWEB)

    Daurelle, J.V.; Cadene, V.; Occelli, R. [Universite de Provence, 13 - Marseille (France)

    1996-12-31

    In the numerical modeling of thermal industrial problems, radiant heat transfers remain difficult to take into account and require important computer memory and long computing time. These difficulties are enhanced when radiant heat transfers are coupled with finite-elements diffusive heat transfers because finite-elements architecture is complex and requires a lot of memory. In the case of radiant heat transfers along mobile boundaries, the methods must be optimized. The model described in this paper concerns the radiant heat transfers between diffuse grey surfaces. These transfers are coupled with conduction transfers in the limits of the diffusive opaque domain. 2-D and 3-D geometries are analyzed and two configurations of mobile boundaries are considered. In the first configuration, the boundary follows the deformation of the mesh, while in the second, the boundary moves along the fixed mesh. Matter displacement is taken into account in the term of transport of the energy equation, and an appropriate variation of the thermophysical properties of the transition elements between the opaque and transparent media is used. After a description of the introduction of radiative limit conditions in a finite-elements thermal model, the original methods used to optimize calculation time are explained. Two examples of application illustrate the approach used. The first concerns the modeling of radiant heat transfers between fuel rods during a reactor cooling accident, and the second concerns the study of heat transfers inside the air-gap of an electric motor. The method of identification of the mobile surface on the fixed mesh is described. (J.S.) 12 refs.

  19. Calculations of Temperature, Conductive Heat Flux, and Heat Wave Velocities Due to Radiant Heating of Opaque Materials

    Science.gov (United States)

    2011-11-01

    presentation and the help of Dr. Anthony Kotlar with the Mathcad calculations are greatly appreciated. vi INTENTIONALLY LEFT BLANK. 1 1. Introduction...Corporation. Mathcad 2001; Needham, MA, 2001. 4. Joseph, D. D.; Preziosi, L. Heat Waves. Rev. Modern Physics 1989, 61 (1), 41–73. 5. Cao, B-Y; Guo, Z-Y

  20. Evaluation of Surface Microhardness and Abrasion Resistance of Two Dental Glass Ionomer Cement Materials after Radiant Heat Treatment

    Directory of Open Access Journals (Sweden)

    Dimitrios Dionysopoulos

    2017-01-01

    Full Text Available The aim of this study was to evaluate the effect of a radiant heat treatment using a dental LED unit on the surface microhardness and abrasion resistance after toothbrushing simulation of two conventional GIC materials. Two conventional GIC materials were studied in this investigation: Ketac Fil Plus Aplicap and IonoStar Molar. Twenty disk-shaped specimens (n=10 were prepared of each GIC (7 mm × 2 mm using cylindrical Teflon molds. Group 1 specimens were left in the mold to set without any treatment, while in Group 2 after placement in the mold the specimens were irradiated for 60 sec at the top surface using a LED light-curing unit. Toothbrushing simulation was carried out using a commercial electric toothbrush which was fixed in a constructed device that allowed the heads of the brushes to be aligned parallel to the surface of the specimens and to control the pressure, with the following parameters: load of the toothbrush standardized at 250 g, medium hardness toothbrush head, and rotation sense changing every 30 sec. The toothbrush abrasion test mechanism, based on a 1.25-Hz frequency for 10,000 cycles, was equivalent to 800 days (~2 years of brushing. Surface hardness, surface roughness, and surface loss after abrasive procedure were evaluated using Vickers method and Vertical Scanning Interferometry. Data were statistically analyzed using one-way ANOVA and Tukey’s post hoc test (a=0.05. The radiant heat treatment increased the surface microhardness and decreased surface roughness and surface loss after abrasive procedures of both the tested GIC materials but to different extent. Between the tested GIC materials there were significant differences in their tested properties (p<0.05.

  1. Effect of radiant heat at the birth site in farrowing crates on hypothermia and behaviour in neonatal piglets.

    Science.gov (United States)

    Andersen, H M-L; Pedersen, L J

    2016-01-01

    It has been documented that floor heating of the farrowing area in loose housed sows improves survival of piglets significantly. However, today, the majority of farrowing pens are designed with crating of sows and slatted floor at the birth site. The aim of this study was to investigate whether providing radiant heat at the birth site to new-born piglets in pens with crated sows reduced hypothermia, time to first milk intake and growth of the piglets during the 1(st) week. Second parity Danish Landrace×Yorkshire sows (n=36) were randomly divided into two groups: Control (CG) and heat (HG). In the area behind the sow (zone 1), two radiant heat panels were mounted above the slatted floor in the HG. The farrowings were attended, and the heaters were turned on at birth of first piglet and turned off 12 h after. Birth time, time to leave zone 1, time to first contact with udder and time to first suckling were registered by direct observation. The piglet's rectal temperature (RT) was measured 15, 30, 60, 120, 180, 240 min after birth and 12, 14 and 24 h after birth of first piglet. Piglets were weighed at birth, 24 and 48 h and 7 days after birth. Data were analysed in a mixed model in SAS. The drop in RT was lower in HG compared with CG (P=0.002), and the RT in HG remained higher than in CG from 30 to 240 min after birth (Ppiglet (P=0.92). Piglets in HG stayed longer in zone 1 than those in CG (P=0.01), whereas time to reach udder (P=0.35) and to first suckling (P=0.56) did not differ. No difference in weight gain was found between piglets in HG and CG at 24 h (P=0.23), 48 h (P=0.28) and 7 days after birth (P=0.44). Birth weight had a positive effect on RT (Pheating behind the sows reduced hypothermia in new-born piglets and indicate that providing heat during the first half hour after birth is important.

  2. Experimental investigation of the influence of the air jet trajectory on convective heat transfer in buildings equipped with air-based and radiant cooling systems

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2015-01-01

    -state and dynamic conditions. With the air-based cooling system, a dependency of the convective heat transfer on the air jet trajectory has been observed. New correlations have been developed, introducing a modified Archimedes number to account for the air flow pattern. The accuracy of the new correlations has been...... evaluated to±15%. Besides the study with an air-based cooling system, the convective heat transfer with a radiant cooling system has also been investigated. The convective flow at the activated surface is mainly driven by natural convection. For other surfaces, the complexity of the flow and the large......The complexity and diversity of airflow in buildings make the accurate definition of convective heat transfer coefficients (CHTCs) difficult. In a full-scale test facility, the convective heat transfer of two cooling systems (active chilled beam and radiant wall) has been investigated under steady...

  3. Radiation from Rocket Exhaust Plumes. Part 1; Inhomogeneous Radiant Heat Transfer from Saturn Type Rocket Exhaust Plumes

    Science.gov (United States)

    Huffaker, Robert M.; Carlson, Donald J.

    1966-01-01

    A radiant heat transfer computer program has been developed by R-AERO-A to calculate radiation from inhomogeneous gases prevalent in Saturn-type exhaust plumes. The radiating species considered in this computer program are water vapor, carbon dioxide, carbon monoxide and carbon particles. The infrared spectral absorption characteristics of these species have been determined under NASA contract. Band model parameters have been used to represent the infrared spectral absorption coefficients over 25 cm-I increments. A modified Curtis-Goodson approximation is used in the inhomogeneous heat transfer calculation. This has been shown to give satisfactory results over the temperature and pressure range of interest in Saturn exhaust plumes. Results are shown for the Saturn-type engines for specific flow field assumptions. Some comparison with experimental spectroscopic data will also be presented. The effect of wavelength increment, field of view, and distance increment along the line of sight on the heat transfer will be discussed. Computer techniques for minimum computer time in calculating radiation from a three-dimensional flow field will also be outlined.

  4. Numerical Modeling of Conjugate Thermogravitational Convection in a Closed System with a Radiant Energy Source in Conditions of Convective-Radiative Heat Exchange at the External Boundary

    Directory of Open Access Journals (Sweden)

    Nee Alexander

    2016-01-01

    Full Text Available Mathematical modeling of conjugate natural convection in a closed rectangular cavity with a radiant energy source in conditions of convective-radiative heat exchange at the external boundary was conducted. The radiant energy distribution was set by the Lambert’s law. Conduction and convection processes analysis showed that the air masses flow pattern is modified slightly over the time. The temperature increases in the gas cavity, despite the heat removal from the one of the external boundary. According to the results of the integral heat transfer analysis were established that the average Nusselt number (Nuav increasing occurs up to τ = 200 (dimensionless time. Further Nuav has changed insignificantly due to the temperature field equalization near the interfaces “gas – wall”.

  5. Field evaluation of performance of radiant heating/cooling ceiling panel system

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    heating/coolingceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiantheating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus,this study aims to not only clarify the system performance but also to share our...... experience and our resultsfor them to serve as a reference for other similar projects. Here, the system performance in relation toits heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient fromwater to room was 3.7 W/(m2K) and 4.8 W/(m2K) for heating and cooling cases...

  6. Design and Control of Hydronic Radiant Cooling Systems

    Science.gov (United States)

    Feng, Jingjuan

    Improving energy efficiency in the Heating Ventilation and Air conditioning (HVAC) systems in buildings is critical to achieve the energy reduction in the building sector, which consumes 41% of all primary energy produced in the United States, and was responsible for nearly half of U.S. CO2 emissions. Based on a report by the New Building Institute (NBI), when HVAC systems are used, about half of the zero net energy (ZNE) buildings report using a radiant cooling/heating system, often in conjunction with ground source heat pumps. Radiant systems differ from air systems in the main heat transfer mechanism used to remove heat from a space, and in their control characteristics when responding to changes in control signals and room thermal conditions. This dissertation investigates three related design and control topics: cooling load calculations, cooling capacity estimation, and control for the heavyweight radiant systems. These three issues are fundamental to the development of accurate design/modeling tools, relevant performance testing methods, and ultimately the realization of the potential energy benefits of radiant systems. Cooling load calculations are a crucial step in designing any HVAC system. In the current standards, cooling load is defined and calculated independent of HVAC system type. In this dissertation, I present research evidence that sensible zone cooling loads for radiant systems are different from cooling loads for traditional air systems. Energy simulations, in EnergyPlus, and laboratory experiments were conducted to investigate the heat transfer dynamics in spaces conditioned by radiant and air systems. The results show that the magnitude of the cooling load difference between the two systems ranges from 7-85%, and radiant systems remove heat faster than air systems. For the experimental tested conditions, 75-82% of total heat gain was removed by radiant system during the period when the heater (simulating the heat gain) was on, while for air

  7. Improvement on life and NO{sub x} discharge of radiant heat transfer tube heating system by the elasto-plasticity creep analysis; Dansosei kuripukaiseki ni yoru hosha dennetsukan kanetsu shisutemu no jumyo to NO{sub x} haishutsuryo no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Futahiko; Ikaruda, Kunihiro; Abe, Yoshio; Arai, Norio

    1999-06-05

    Combustion thermal process using the radiant heat transfer tube has widely been applied as a heating method which separates the combustion atmosphere from the heating-e atmosphere in various heating furnace such as iron and steel industry. In this thermal process, in order to burn the fuel in tight space in radiant heat transfer service area, radiant heat transfer tube and burner life were short under high temperature and high-load combustion, and there was a problem that that and, burning characteristic such as NO{sub x} generation rate are improved was difficult. In this study, large temperature distribution by the combustion in the radiant heat transfer tube clarified that the life of the radiant heat transfer tube was shortened by elasto-plasticity creep analysis of the radiant heat transfer tube. Then, two steps combustion burner of the exhaust gas self recycling type was developed as a method for reducing the NO{sub x} generation rate, while the temperature distribution of the radiant heat transfer tube was equalized. As the result, it was possible to reduce over 20% in comparison with conventional two steps combustion burner, while radiant heat transfer tube and life of the burner are extended over the conventional double, in respect of the NO{sub x} generation rate. (translated by NEDO)

  8. Operative temperature drifts and occupant satisfaction with thermal environment in three office buildings using radiant heating/ cooling system

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Olesen, Bjarne W.

    2015-01-01

    The objective of this study was to analyse operative temperature drifts and occupant satisfaction with thermal environment in office buildings utilizing embedded radiant heating/cooling systems. Three office buildings were investigated: Town Hall in Viborg, Denmark (floor area 19400 m2), IDOM......, Madrid, Spain (16000 m2), TiFS, Padua, Italy (2200 m2). Continuous measurements of operative temperature were conducted at four workplaces in each building for one year. Occupants’ satisfaction was assessed by internet based questionnaire. Results showed that mostly exceeded limits were those for 4-hour...... drift (0.8 K/h), which were exceeded at least in 2% and up to 52% of occupied time in investigated buildings. Limits for hourly and 2-hour drifts were exceeded in max. 2% of occupied time. Median values were in ranges of 0.12-0.29 K/h, 0.18-0.52 K/h and 0.27-0.84 K/h for 1, 2 and 4-hour drifts...

  9. Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445 nm).

    Science.gov (United States)

    Dionysopoulos, Dimitrios; Tolidis, Kosmas; Strakas, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos; Gutknecht, Norbert

    2017-04-01

    The aim of this in vitro study was to evaluate the effect of radiant heat on surface hardness of three conventional glass ionomer cements (GICs) by using a blue diode laser system (445 nm) and a light-emitting diode (LED) unit. Additionally, the safety of the laser treatment was evaluated. Thirty disk-shaped specimens were prepared of each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: group 1 was the control group of the study; in group 2, the specimens were irradiated for 60 s at the top surface using a LED light-curing unit; and in group 3, the specimens were irradiated for 60 s at the top surface using a blue light diode laser system (445 nm). Statistical analysis was performed using one-way ANOVA and Tukey post-hoc tests at a level of significance of a = 0.05. Radiant heat treatments, with both laser and LED devices, increased surface hardness (p diode laser treatment was seemed to be more effective compared to LED treatment. There were no alterations in surface morphology or chemical composition after laser treatment. The tested radiant heat treatment with a blue diode laser may be advantageous for the longevity of GIC restorations. The safety of the use of blue diode laser for this application was confirmed.

  10. Effects of blue diode laser (445 nm) and LED (430-480 nm) radiant heat treatments on dental glass ionomer restoratives

    Science.gov (United States)

    Dionysopoulos, Dimitrios; Tolidis, Kosmas; Strakas, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos; Gutknecht, Norbert

    2018-02-01

    The purpose of this in vitro study was to evaluate the effect of two radiant heat treatments on water sorption, solubility and surface roughness of three conventional glass ionomer cements by using a blue diode laser (445 nm) and a light emitting diode (LED) unit (430-480 nm). Thirty disk-shaped specimens were prepared for each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: Group 1 was the control group, in Group 2 the specimens were irradiated for 60 s at the top surface using a LED light-curing unit and in Group 3 the specimens were irradiated for 60 s at the top surface using a blue light diode laser. Statistical analysis was performed using one-way ANOVA and Tukey post hoc tests at a level of significance of a = 0.05. Radiant heat treatments with both laser and LED devices significantly decreased water sorption and solubility (p 0.05). Among the tested materials there were differences in water sorption and solubility (p 0.05). The use of the blue diode laser for this radiant heat treatment was harmless for the surface of the tested GICs and may be advantageous for the longevity of their restorations.

  11. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group; German, A. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group; Dakin, B. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group; Springer, D. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  12. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  13. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  14. Numerical Study of the Thermally Conductive Finite Thickness Walls Impact on Heat Transfer Regime in a Closed System in Conditions of Radiant Energy Supply

    Directory of Open Access Journals (Sweden)

    Nee A. E.

    2015-01-01

    Full Text Available Plane problem of thermogravitational convection in a closed rectangular cavity is numerically solved in conditions of radiant energy supply to the one of the boundaries. Differential heat transfer parameters (fields of temperatures and stream functions for the conjugate (only vertical walls, only horizontal, vertical and horizontal walls and the nonconjugate formulation are obtained. Temperature distributions in the Y direction in the cross section along the axis of symmetry showed that the presence of heat-conducting finite thickness walls leads to a redistribution of the energy which is accumulated by gas and enclosure structures.

  15. Effects of an Arctic under-ice bloom on solar radiant heating of the water column

    Science.gov (United States)

    Taskjelle, Torbjørn; Granskog, Mats A.; Pavlov, Alexey K.; Hudson, Stephen R.; Hamre, Børge

    2017-01-01

    The deposition of solar energy in the upper Arctic Ocean depends, among other things, on the composition of the water column. During the N-ICE2015 expedition, a drift in the Arctic pack ice north of Svalbard, an under-ice phytoplankton bloom was encountered in May 2015. This bloom led to significant changes in the inherent optical properties (IOPs) of the upper ocean. Mean values of total water absorption in the upper 20 m of the water column were up to 4 times higher during the bloom than prior to it. The total water attenuation coefficient increased by a factor of up to around 7. Radiative transfer modeling, with measured IOPs as input, has been performed with a coupled atmosphere-ice-ocean model. Simulations are used to investigate the change in depth-dependent solar heating of the ocean after the onset of the bloom, for wavelengths in the region 350-700 nm. Effects of clouds, sea ice cover, solar zenith angle, as well as the average cosine for scattering of the ocean inclusions are evaluated. An increase in energy absorption in the upper 10 m of about 36% is found under 25 cm ice with 2 cm snow, for bloom conditions relative to prebloom conditions, which may have implications for ice melt and growth in spring. Thicker clouds and lower sun reduce the irradiance available, but lead to an increase in relative absorption.

  16. Coupling of a discrete ordinate 3-D radiant heat transfer model with the PHOENICS fluid mechanics software; Couplage d`un modele radiatif tridimensionnel aux ordonnees discretes au logiciel de mecanique des fluides phoenics

    Energy Technology Data Exchange (ETDEWEB)

    Muller, J. [IRSID, Institut de Recherches Siderurgie, 57 - Maizieres-les-Metz (France)

    1996-12-31

    Radiant heat transfer is the main solution retained in many iron and steel metallurgy installations (re-heating and annealing furnaces etc..). Today, it has become important to dispose of performing radiant heat transfer models in heat transfer and fluid mechanics simulation softwares, and well adapted to multidimensional industrial problems. This work presents the discrete ordinate radiant heat transfer model developed at the IRSID (the French institute of research in iron and steel metallurgy) and coupled with the PHOENICS heat transfer-fluid mechanics software. Three modeling approaches are presented concerning the radiative properties of gases (H{sub 2}O-CO{sub 2}). A ``weighted grey gases sum`` model gives satisfactory results for several 1-D validation cases. (J.S.) 20 refs.

  17. Facilitation of a nociceptive flexion reflex in man by nonnoxious radiant heat produced by a laser.

    Science.gov (United States)

    Plaghki, L; Bragard, D; Le Bars, D; Willer, J C; Godfraind, J M

    1998-05-01

    Electromyographic recordings were made in healthy volunteers from the knee-flexor biceps femoris muscle of the nociceptive RIII reflex elicited by electrical stimulation of the cutaneous sural nerve. The stimulus intensity was adjusted to produce a moderate pricking-pain sensation. The test responses were conditioned by a nonnoxious thermal (CO2 laser stimulator and consisted of a 100-ms pulse of heat with a beam diameter of 20 mm. Its power was 22.7 +/- 4.2 W (7.2 mJ/mm2), and it produced a sensation of warmth. The maximum surface temperature reached at the end of the period of stimulation was calculated to be 7 degrees C above the actual reference temperature of the skin (32 degrees C). The interval between the laser (conditioning) and electrical (test) stimuli was varied from 50 to 3, 000 ms in steps of 50 ms. It was found that the nociceptive flexion reflex was facilitated by the thermal stimulus; this modulation occurred with particular conditioning-test intervals, which peaked at 500 and 1,100 ms with an additional late, long-lasting phase between 1,600 and 2,300 ms. It was calculated that the conduction velocities of the cutaneous afferent fibers responsible for facilitating the RIII reflex, fell into three ranges: one corresponding to A delta fibers (3.2 m/s) and two in the C fiber range (1.3 and 0.7 m/s). It is concluded that information emanating from warm receptors and nociceptors converges. In this respect, the present data show, for the first time, that in man, conditioning nonnociceptive warm thermoreceptive A delta and C fibers results in an interaction at the spinal level with a nociceptive reflex. This interaction may constitute a useful means whereby signals add together to trigger flexion reflexes in defensive reactions and other basic motor behaviors. It also may contribute to hyperalgesia in inflammatory processes. The methodology used in this study appears to be a useful noninvasive tool for exploring the thermoalgesic mechanisms in both

  18. 16 CFR 1209.6 - Test procedures for critical radiant flux.

    Science.gov (United States)

    2010-01-01

    ... energy source. The radiant heat energy source shall be a panel of porous refractory material mounted in a... for monitoring and controlling the flow of fuel to the panel. (3) The radiant heat energy panel shall... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and...

  19. A system for the comparison of tools for the simulation of water-based radiant heating and cooling systems

    DEFF Research Database (Denmark)

    Behrendt, Benjamin; Raimondo, Daniela; Zhang, Ye

    2011-01-01

    increase of water based radiant systems in modern buildings and a need for reliable simulation tools to predict the indoor environment and energy performance. This paper describes the comparison of the building simulation tools IDA ICE, IES , EnergyPlus and TRNSYS. The simulation tools are compared to each...

  20. Radiant Professionals Alliance guidelines 2010

    CERN Document Server

    IAPMO

    2010-01-01

    RPA Guidelines for the Design and Installation of Radiant Panel Heating and Snow/Ice Melt Systems. Intended for reference use by code officials, designers and installers. Deals with both hydronic and electric floor, wall and limited ceiling applications. Includes sample schematics and industry recommendations.

  1. System and method for determining the net output torque from a waste heat recovery system

    Science.gov (United States)

    Tricaud, Christophe; Ernst, Timothy C.; Zigan, James A.

    2016-12-13

    The disclosure provides a waste heat recovery system with a system and method for calculation of the net output torque from the waste heat recovery system. The calculation uses inputs from existing pressure and speed sensors to create a virtual pump torque sensor and a virtual expander torque sensor, and uses these sensors to provide an accurate net torque output from the WHR system.

  2. Heat Mismatch of future Net Zero Energy Buildings within district heating areas in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    . NZEBs are characterized by having a greatly reduced energy demand that on an annual basis can be balanced out by an equivalent generation of energy from RES. Most buildings in Denmark are connected electricity grids and around half to district heating (DH) systems. Connecting buildings to larger energy...... instead of wasting the energy. The objective in this paper is find how large an area of NZEBs is to be built within DH areas and how the heat mismatch of NZEBs influence different types of Danish DH systems. In the analyses nine different scenarios are analyzed. The examination is from a technical......The long-term goal for Denmark is to develop an energy system solely based on renewable energy sources (RES) in 2050. To reach this goal energy savings in buildings are essential. Therefore, a focus on energy efficient measures in buildings and net zero energy buildings (NZEBs) have increased...

  3. Energy flow and thermal comfort in buildings: Comparison of radiant and air-based heating & cooling systems

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme

    is based on both radiation and convection. This thesis focuses on characterizing the heat transfer from the terminal towards the space and on the parameters influencing the effectiveness of terminals. Therefore the comfort conditions and energy consumption of four types of terminals (active chilled beam...

  4. Consumer Unit for Low Energy District Heating Net

    DEFF Research Database (Denmark)

    Paulsen, Otto; Fan, Jianhua; Furbo, Simon

    2008-01-01

    heat load on a daily basis, having a flow temperature control based on outdoor climate. The unit is designed for a near constant district heating water flow. The paper describes two concepts. The analyses are based on TRNSYS (Klein et al., 2006) simulation, supplied with laboratory verification...

  5. Differences in the heat stress associated with white sportswear and being semi-nude in exercising humans under conditions of radiant heat and wind at a wet bulb globe temperature of greater than 28 °C.

    Science.gov (United States)

    Tsuji, Michio; Kume, Masashi; Tuneoka, Hideyuki; Yoshida, Tetsuya

    2014-08-01

    This study investigated whether wearing common white sportswear can reduce heat stress more than being semi-nude during exercise of different intensities performed under radiant heat and wind conditions, such as a hot summer day. After a 20-min rest period, eight male subjects performed three 20 min sessions of cycling exercise at a load intensity of 20 % or 50 % of their peak oxygen uptake (VO2peak) in a room maintained at a wet bulb globe temperature (WBGT) of 28.7 ± 0.1 °C using two spot lights and a fan (0.8 m/s airflow). Subjects wore common white sportswear (WS) consisting of a long-sleeved shirt (45 % cotton and 55 % polyester) and short pants (100 % polyester), or only swimming pants (SP) under the semi-nude condition. The mean skin temperature (Tsk) was greater when subjects wore SP than WS under both the 20 % and 50 % exercise conditions. During the 50 % exercise, the rating of perceived exertion (RPE) and thermal sensation (TS), and the increases in esophageal temperature (ΔTes) and heart rate were significantly higher (Pwind at a WBGT greater than 28 °C, the heat stress associated with wearing common WS is similar to that of being semi-nude during light exercise, but was greater during moderate exercise, and the storage of body heat can be reduced by wearing WS during rest periods.

  6. An oral TRPV1 antagonist attenuates laser radiant-heat-evoked potentials and pain ratings from UV(B)-inflamed and normal skin.

    Science.gov (United States)

    Schaffler, Klaus; Reeh, Peter; Duan, W Rachel; Best, Andrea E; Othman, Ahmed A; Faltynek, Connie R; Locke, Charles; Nothaft, Wolfram

    2013-02-01

    Laser (radiant-heat) evoked potentials (LEPs) from vertex-EEG peak-to-peak (PtP) amplitude were used to determine acute antinociceptive/antihyperalgesic efficacy of ABT-102, a novel TRPV1 antagonist efficacious in preclinical pain models, compared with active controls and placebo in normal and UV(B)-inflamed skin. This was a randomized, placebo- and active-controlled, double-blind, intra-individual, crossover trial. Twenty-four healthy subjects received six sequences of single doses of ABT-102 (0.5, 2, 6 mg), etoricoxib 90 mg, tramadol 100 mg and placebo. Painful stimuli were induced by CO(2) -laser on normal and UV(B) -inflamed skin. LEPs and visual analogue scale (VAS-pain) ratings were taken at baseline and hourly up to 8 h post-dose from both skin types. Compared with placebo, significant mean decreases in the primary variable of LEP PtP-amplitude from UV(B)-inflamed skin were observed with ABT-102 6 mg (P < 0.001), ABT-102 2 mg (P = 0.002), tramadol 100 mg (P < 0.001), and etoricoxib 90 mg (P = 0.001) over the 8 h period; ABT-102 0.5 mg was similar to placebo. ABT-102 6 mg was superior to active controls over the 8 h period (P < 0.05) whereas ABT-102 2 mg was comparable. Improvements in VAS scores compared with placebo were observed with ABT-102 6 mg (P < 0.001) and ABT-102 2 mg (P = 0.002). ABT-102 average plasma concentrations were 1.3, 4.4 and 9.4 ng ml(-1) for the 0.5, 2 and 6 mg doses, respectively. There were no clinically significant safety findings. TRPV-1 antagonism appears promising in the management of clinical pain, but requires further investigation. © 2012 Abbott. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  7. Evaluation of Advanced Stirling Convertor Net Heat Input Correlation Methods Using a Thermal Standard

    Science.gov (United States)

    Briggs, Maxwell H.; Schifer, Nicholas A.

    2012-01-01

    The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. In an effort to improve net heat input predictions, numerous tasks have been performed which provided a more accurate value for net heat input into the ASCs, including testing validation hardware, known as the Thermal Standard, to provide a direct comparison to numerical and empirical models used to predict convertor net heat input. This validation hardware provided a comparison for scrutinizing and improving empirical correlations and numerical models of ASC-E2 net heat input. This hardware simulated the characteristics of an ASC-E2 convertor in both an operating and non-operating mode. This paper describes the Thermal Standard testing and the conclusions of the validation effort applied to the empirical correlation methods used by the Radioisotope Power System (RPS) team at NASA Glenn.

  8. Numerical Computation of Net Radiative Heat Transfer within a Non Absorbing Furnace Enclosure

    Directory of Open Access Journals (Sweden)

    Shuaibu Ndache MOHAMMED

    2006-07-01

    Full Text Available The numerical evaluation of the net radiative heat transfer rate in a single zone, non absorbing furnace enclosure is reported. In this analysis, simplified mathematical furnace model namely, the long furnace model is used to determine furnace performance. The formulation assumes some known temperature values. Thus, heat transfer equations were set up and solved numerically. A FORTRAN computer program was developed and debugged. Results obtained from this study compare favourably well with the results from the traditional graphical method. Also, the computer program developed can handle variations in furnace operating conditions, temperatures, thermal properties and dimensions.

  9. Excess heat production of future net zero energy buildings within district heating areas in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    2012-01-01

    buildings in Denmark are connected to electricity grids and around half are connected to districtheating (DH) systems. Connecting buildings to larger energy systems enables them to send and receive energy from these systems. This paper’s objective is to examine how excess heat production from NZEBs...... excess heat production from solar thermal collectors. The main findings are that the excess heat from NZEBs can benefit DH systems by decreasing the production from production units utilizing combustible fuels. In DH areas where the heat demand in summer months is already covered by renewable energy......Denmark’s long-term energy goal is to develop an energy system solely based on renewable energy sources by 2050. To reach this goal, energy savings in buildings is essential. Therefore, the focus on energy efficient measures in buildings and netzeroenergybuildings (NZEBs) has increased. Most...

  10. Application of a radiant heat transfer model to complex industrial reactive flows: combustion chambers, electric arcs; Application d`un modele de transfert radiatif a des ecoulements reactifs industriels complexes: chambres de combustion, arcs electriques

    Energy Technology Data Exchange (ETDEWEB)

    Mechitoua, N.; Dalsecco, S.; Delalondre, C.; Simonin, O. [Electricite de France (EDF), 78 - Chatou (France). Lab. National d`Hydraulique

    1996-12-31

    The direction of studies and researches (DER) of Electricite de France (EdF) has been involved for several years in a research program on turbulent reactive flows. The objectives of this program concern: the reduction of pollutant emissions from existing fossil-fueled power plants, the study of new production means (fluidized beds), and the promotion of electric power applications in the industry. An important part of this program is devoted to the development and validation of 3-D softwares and to the modeling of physical phenomena. This paper presents some industrial applications (furnaces, boilers, electric arcs) for which radiant heat transfers play an important role and the radiation models used. (J.S.) 8 refs.

  11. Thermal model of attic systems with radiant barriers

    Energy Technology Data Exchange (ETDEWEB)

    Wilkes, K.E.

    1991-07-01

    This report summarizes the first phase of a project to model the thermal performance of radiant barriers. The objective of this phase of the project was to develop a refined model for the thermal performance of residential house attics, with and without radiant barriers, and to verify the model by comparing its predictions against selected existing experimental thermal performance data. Models for the thermal performance of attics with and without radiant barriers have been developed and implemented on an IBM PC/AT computer. The validity of the models has been tested by comparing their predictions with ceiling heat fluxes measured in a number of laboratory and field experiments on attics with and without radiant barriers. Cumulative heat flows predicted by the models were usually within about 5 to 10 percent of measured values. In future phases of the project, the models for attic/radiant barrier performance will be coupled with a whole-house model and further comparisons with experimental data will be made. Following this, the models will be utilized to provide an initial assessment of the energy savings potential of radiant barriers in various configurations and under various climatic conditions. 38 refs., 14 figs., 22 tabs.

  12. Elevated CO2 maintains grassland net carbon uptake under a future heat and drought extreme.

    Science.gov (United States)

    Roy, Jacques; Picon-Cochard, Catherine; Augusti, Angela; Benot, Marie-Lise; Thiery, Lionel; Darsonville, Olivier; Landais, Damien; Piel, Clément; Defossez, Marc; Devidal, Sébastien; Escape, Christophe; Ravel, Olivier; Fromin, Nathalie; Volaire, Florence; Milcu, Alexandru; Bahn, Michael; Soussana, Jean-François

    2016-05-31

    Extreme climatic events (ECEs) such as droughts and heat waves are predicted to increase in intensity and frequency and impact the terrestrial carbon balance. However, we lack direct experimental evidence of how the net carbon uptake of ecosystems is affected by ECEs under future elevated atmospheric CO2 concentrations (eCO2). Taking advantage of an advanced controlled environment facility for ecosystem research (Ecotron), we simulated eCO2 and extreme cooccurring heat and drought events as projected for the 2050s and analyzed their effects on the ecosystem-level carbon and water fluxes in a C3 grassland. Our results indicate that eCO2 not only slows down the decline of ecosystem carbon uptake during the ECE but also enhances its recovery after the ECE, as mediated by increases of root growth and plant nitrogen uptake induced by the ECE. These findings indicate that, in the predicted near future climate, eCO2 could mitigate the effects of extreme droughts and heat waves on ecosystem net carbon uptake.

  13. Temporal and spatial changes in mixed layer properties and atmospheric net heat flux in the Nordic Seas

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, A; Alekseev, G [SI ' Arctic and Antarctic Research Institute' , St. Petersburg (Russian Federation); Korablev, A; Esau, I, E-mail: avsmir@aari.nw.r [Nansen Environmental and Remote Sensing Centre, Bergen (Norway)

    2010-08-15

    The Nordic Seas are an important area of the World Ocean where warm Atlantic waters penetrate far north forming the mild climate of Northern Europe. These waters represent the northern rim of the global thermohaline circulation. Estimates of the relationships between the net heat flux and mixed layer properties in the Nordic Seas are examined. Oceanographic data are derived from the Oceanographic Data Base (ODB) compiled in the Arctic and Antarctic Research Institute. Ocean weather ship 'Mike' (OWS) data are used to calculate radiative and turbulent components of the net heat flux. The net shortwave flux was calculated using a satellite albedo dataset and the EPA model. The net longwave flux was estimated by Southampton Oceanography Centre (SOC) method. Turbulent fluxes at the air-sea interface were calculated using the COARE 3.0 algorithm. The net heat flux was calculated by using oceanographic and meteorological data of the OWS 'Mike'. The mixed layer depth was estimated for the period since 2002 until 2009 by the 'Mike' data as well. A good correlation between these two parameters has been found. Sensible and latent heat fluxes controlled by surface air temperature/sea surface temperature gradient are the main contributors into net heat flux. Significant correlation was found between heat fluxes variations at the OWS 'Mike' location and sea ice export from the Arctic Ocean.

  14. Experimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Qiang Si

    2016-12-01

    Full Text Available In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning. The indoor terminal device is the radiant induction-unit (RIDU. The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed. The two-stage evaporator chiller with the non-azeotropic mixture refrigerant is utilized in the system to reduce the initial investment in equipment. With the performance test and the steady state heat transfer model based on the theory of radiative heat transfer, the relationship between the induction ratio of the RIDU and the characteristic of the air supply was studied. Based on this, it is verified that the RIDU has a lower dew-point temperature and better anti-condensation performance than a traditional plate-type radiant panel. The characteristics of the radiation and convection heat transfer of the RIDU were studied. The total heat exchange of the RIDU can be 16.5% greater than that of the traditional plate-type radiant terminal.

  15. Testing and thermal modeling of radiant panels systems as commissioning tool

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca Diaz, Nestor, E-mail: njfonseca@doct.ulg.ac.b [University of Liege Belgium, Thermodynamics Laboratory, Campus du Sart Tilman, Bat: B49, P33, B-4000 Liege (Belgium); Universidad Tecnologica de Pereira, Facultad de Ingenieria Mecanica, AA 97 Pereira (Colombia); Cuevas, Cristian [Universidad de Concepcion, Facultad de Ingenieria, Departamento de Ingenieria Mecanica, Casilla 160c Concepcion (Chile)

    2010-12-15

    This paper presents the results of a study performed to develop a thermal modeling of radiant panels systems to be used in situ, as diagnosis tool in commissioning processes to determine the main operating conditions of the system in cooling or heating mode. The model considers the radiant panels as a finned heat exchanger in dry regime. By using as inputs the ceiling and room dimensions, the radiant ceiling material properties and the measurements of air and water mass flow rates and temperatures, the model is able to calculate the radiant ceiling capacity, ceiling surface average temperature, water exhaust temperature and resultant temperature as a comfort indicator. The modeling proposed considers combined convection, perforation effect and a detailed radiative heat exchange method for radiant ceiling systems. An example of each system considered in this study is shown, illustrating the validation of the model. A sensitive analysis of the model is performed.

  16. Radiant recuperator modelling and design

    Directory of Open Access Journals (Sweden)

    Knežević Suzana D.

    2017-01-01

    Full Text Available Recuperators are frequently used in glass production and metallurgical processes to preheat combustion air by heat exchange with high temperature flue gases. Mass and energy balances of a 15 m high, concurrent radiant recuperator used in a glass fiber production process are given. The balances are used: for validation of a cell modeling method that predicts the performance of different recuperator designs, and for finding a simple solution to improve the existing recuperator. Three possible solutions are analyzed: to use the existing recuperator as a countercurrent one, to add an extra cylinder over the existing construction, and to make a system that consists of a central pipe and two concentric annular ducts. In the latter, two air streams flow in opposite directions, whereas air in the inner annular passage flows concurrently or countercurrently to flue gases. Compared with the concurrent recuperator, the countercurrent has only one drawback: the interface temperature is higher at the bottom. The advantages are: lower interface temperature at the top where the material is under maximal load, higher efficiency, and smaller pressure drop. Both concurrent and countercurrent double pipe-in-pipe systems are only slightly more efficient than pure concurrent and countercurrent recuperators, respectively. Their advantages are smaller interface temperatures whereas the disadvantages are their costs and pressure drops. To implement these solutions, the average velocities should be: for flue gas around 5 m/s, for air in the first passage less than 2 m/s, and for air in the second passage more than 25 m/s. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. EE 33027

  17. Modeling of radiant heat transfers in non-grey gases using the discrete ordinate method in association with a narrow bands statistical model; Modelisation des transferts radiatifs dans des gaz non gris par la methode des ordonnees discretes associee a un modele statistique a bandes etroites

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, A.B. de; Delmas, A.; Sacadura, J.F. [Institut National des Sciences Appliquees (INSA), 69 - Villeurbanne (France)

    1996-12-31

    A formulation based on the use of the discrete ordinate method applied to the integral form of the radiant heat transfer equation is proposed for non-grey gases. The correlations between transmittances are neglected and no explicit wall reflexion is considered. The configuration analyzed consists in a flat layer of non-isothermal steam-nitrogen mixture. Cavity walls are grey with diffuse reflexion and emission. A narrow band statistical model is used to represent the radiative properties of the gas. The distribution of the radiative source term inside the cavity is calculated along two temperature profiles in a uniform steam concentration. Results obtained using this simplified approach are in good agreement with those found in the literature for the same temperature and concentration distributions. This preliminary study seems to indicate that the algorithm based on the integration of radiant heat transfer along the luminance path is less sensitive to de-correlation effects than formulations based on the differential form the the radiant heat transfer. Thus, a more systematic study of the influence of the neglecting of correlations on the integral approach is analyzed in this work. (J.S.) 16 refs.

  18. Evaluation of infrared radiant heaters for Army applications

    Energy Technology Data Exchange (ETDEWEB)

    Kedl, R.J.

    1987-11-01

    This report evaluates the use of infrared radiant heaters for Army applications. Radiant-heater operation and the kinds of heaters available are described. Based on information published in the literature and furnished by the manufacturers, energy savings of 20 to 50% can be expected, compared with conventional heating systems. The greatest savings are usually associated with large industrial-type buildings with high roofs, poor insulation, and high infiltration. High-bay maintenance shops and aircraft hangars, which are common in the Army, are ideal candidates for gas- or oil-fired radiant heaters (both new and retrofit applications). A simple payback period of 2 to 5 years is estimated achievable for a retrofit installation when the fuel cost is $4/MBtu or more and the fuel savings are 40% or more. A program that would lead to a better understanding of the fuel saving potential for different classes of buildings is recommended.

  19. Radiant non-catalytic recuperative reformer

    Energy Technology Data Exchange (ETDEWEB)

    Khinkis, Mark J.; Kozlov, Aleksandr P.

    2017-10-31

    A radiant, non-catalytic recuperative reformer has a flue gas flow path for conducting hot exhaust gas from a thermal process and a reforming mixture flow path for conducting a reforming mixture. At least a portion of the reforming mixture flow path is positioned adjacent to the flue gas flow path to permit heat transfer from the hot exhaust gas to the reforming mixture. The reforming mixture flow path contains substantially no material commonly used as a catalyst for reforming hydrocarbon fuel (e.g., nickel oxide, platinum group elements or rhenium), but instead the reforming mixture is reformed into a higher calorific fuel via reactions due to the heat transfer and residence time. In a preferred embodiment, a portion of the reforming mixture flow path is positioned outside of flue gas flow path for a relatively large residence time.

  20. Achievement of Sustained Net Plasma Heating in a Fusion Experiment with the Optometrist Algorithm.

    Science.gov (United States)

    Baltz, E A; Trask, E; Binderbauer, M; Dikovsky, M; Gota, H; Mendoza, R; Platt, J C; Riley, P F

    2017-07-25

    Many fields of basic and applied science require efficiently exploring complex systems with high dimensionality. An example of such a challenge is optimising the performance of plasma fusion experiments. The highly-nonlinear and temporally-varying interaction between the plasma, its environment and external controls presents a considerable complexity in these experiments. A further difficulty arises from the fact that there is no single objective metric that fully captures both plasma quality and equipment constraints. To efficiently optimise the system, we develop the Optometrist Algorithm, a stochastic perturbation method combined with human choice. Analogous to getting an eyeglass prescription, the Optometrist Algorithm confronts a human operator with two alternative experimental settings and associated outcomes. A human operator then chooses which experiment produces subjectively better results. This innovative technique led to the discovery of an unexpected record confinement regime with positive net heating power in a field-reversed configuration plasma, characterised by a >50% reduction in the energy loss rate and concomitant increase in ion temperature and total plasma energy.

  1. Advanced radiant combustion system. Final report, September 1989--September 1996

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, J.D.; Carswell, M.G.; Long, F.S.

    1996-09-01

    Results of the Advanced Radiant Combustion System (ARCS) project are presented in this report. This work was performed by Alzeta Corporation as prime contractor under a contract to the U.S. Department of Energy Office of Industrial Technologies as part of a larger DOE program entitled Research Program for Advanced Combustion Systems. The goals of the Alzeta ARCS project were to (a) Improve the high temperature performance characteristics of porous surface ceramic fiber burners, (b) Develop an Advanced Radiant Combustion System (ARCS) that combines combustion controls with an advanced radiant burner, and (c) Demonstrate the advanced burner and controls in an industrial application. Prior to the start of this project, Alzeta had developed and commercialized a porous surface radiant burner, the Pyrocore{trademark} burner. The product had been commercially available for approximately 5 years and had achieved commercial success in a number of applications ranging from small burners for commercial cooking equipment to large burners for low temperature industrial fluid heating applications. The burner was not recommended for use in applications with process temperatures above 1000{degrees}F, which prevented the burner from being used in intermediate to high temperature processes in the chemical and petroleum refining industries. The interest in increasing the maximum use temperature of the burner was motivated in part by a desire to expand the number of applications that could use the Pyrocore product, but also because many of the fluid sensitive heating applications of interest would benefit from the distributed flux characteristic of porous surface burners. Background information on porous surface radiant burners, and a discussion of advantages that would be provided by an improved product, are presented in Section 2.

  2. Surface Oxide Net Charge of a Titanium Alloy; Comparison Between Effects of Treatment With Heat or Radiofrequency Plasma Glow Discharge

    Science.gov (United States)

    MacDonald, Daniel E.; Rapuano, Bruce E.; Schniepp, Hannes C.

    2010-01-01

    In the current study, we have compared the effects of heat and radiofrequency plasma glow discharge (RFGD) treatment of a Ti6Al4V alloy on the physico-chemical properties of the alloy’s surface oxide. Titanium alloy (Ti6Al4V) disks were passivated alone, heated to 600 °C, or RFGD plasma treated in pure oxygen. RFGD treatment did not alter the roughness, topography, elemental composition or thickness of the alloy’s surface oxide layer. In contrast, heat treatment altered oxide topography by creating a pattern of oxide elevations approximately 50–100 nm in diameter. These nanostructures exhibited a three-fold increase in roughness compared to untreated surfaces when RMS roughness was calculated after applying a spatial high-pass filter with a 200 nm cutoff wavelength. Heat treatment also produced a surface enrichment in aluminum and vanadium oxides. Both RFGD and heat treatment produced similar increases in oxide wettability. Atomic force microscopy (AFM) measurements of metal surface oxide net charge signified by a long range force of attraction to or repulsion from a (negatively charged) silicon nitride AFM probe were also obtained for all three experimental groups. Force measurements showed that the RFGD-treated Ti6Al4V samples demonstrated a higher net positive surface charge at pH values below 6 and a higher net negative surface charge at physiological pH (pH values between 7 and 8) compared to control and heat-treated samples These findings suggest that RFGD treatment of metallic implant materials can be used to study the role of negatively charged surface oxide functional groups in protein bioactivity, osteogenic cell behavior and osseointegration independently of oxide topography. PMID:20880672

  3. Radiant Cooling for Closed-Loop Water Containment: Exploration of Possible Application in Dry Docks

    Science.gov (United States)

    2015-08-20

    Radiant Cooling For Closed-Loop Water Containment: Exploration of Possible Application in Dry Docks by Trevor R. Murphy, Mechanical...Organization: SPAWAR Sponsoring Organization: NESDI Keywords: Dry Dock Cooling, Heat Transfer, Closed Loop, Pipe System, Cost, Pareto List of Programs...provide data for estimating the cost of implementing a closed-loop radiant cooling system for ships in dry docks . Depending on the material used, pipe

  4. Experimental testing of cooling internal loads with a radiant wall

    OpenAIRE

    Romaní Picas, Joaquim; Cabeza, Luisa F.; Pérez Luque, Gabriel; Pisello, Anna Laura; Gracia Cuesta, Alvaro de

    2018-01-01

    Thermally activated building systems (TABS) consist of pipes or ducts embedded in the building structure. This is a well-known technology for its capability to reduce energy use for cooling buildings. Additionally, TABS help integrating renewable energies, such as free-cooling with ground heat exchangers (GHE). However, TABS cooling load is sensitive to the internal load, and the use of GHE for free-cooling is limited to low energy buildings. In a previously published research, a radiant wall...

  5. Annual and Seasonal Variability of Net Heat Budget in the Northern Indian Ocean

    Science.gov (United States)

    Pinker, Rachel T.; Bentamy, Abderrahim; Chen, Wen; Kumar, M. R. Ramesh; Mathew, Simi; Venkatesan, Ramasamy

    2017-04-01

    In this study we investigate the spatial and temporal features of the net heat budget over the Northern Indian Ocean (focusing on the Arabian Sea and the Bay of Bengal), using satellite and numerical model estimates. The main objective is to characterize the annual, seasonal, and inter-annual patterns over this basin of climatic significance. To assess the temporal variability, several turbulent and radiative fluxes are used The turbulent fluxes are based on information from the Institut Français pout la Recherche et l'Exploitation de la MER (IFREMER V3), the Hamburg Ocean-Atmosphere Parameters from Satellite (HOAPS V3), the SEAFLUX V1, the Japanese Ocean Flux Data sets with Use of Remote Sensing Observations (J-OFURO V2), the Objective Analysis Fluxes (OAFlux V2), the European Center for Medium Weather Forecasts (ECMWF), the ERA Interim, the National centers for Environmental Prediction (NCEP) Climate Forecast System Reanalysis, CFSR, and the National Aeronautics Space Administration (NASA) Modern Era Retrospective Analysis for Research and Application (MERRA). The radiative fluxes, both shortwave and longwave, include those produced at the University of Maryland (UMD) as well as those derived from several of the above mentioned numerical models. An attempt will be made to evaluate the various fluxes against buoy observations such as those from the RAMA array. The National Institute of Ocean Technology, Chennai, India under its Ocean Observation Program has deployed a series of OMNI Buoys both in the Arabian Sea and the Bay of Bengal. These buoys are equipped with sensors to measure the radiation as well as other parameters. Comparison has been done with the OMNI observations and good agreement has been found with the current set-up of the instrument at a 3 m level. We found significant differences between the various products at specific locations. The ultimate objective is to investigates the sources of the differences in terms of atmospheric variables (surface

  6. Downward Heat Penetration below Seasonal Thermocline and its Impact on Sea Surface Temperature Variation Affected by Net Heat Flux during Summer Season

    Science.gov (United States)

    Hosoda, S.; Nonaka, M.; Tomita, T.; Taguchi, B.; Tomita, H.; Iwasaka, N.

    2016-02-01

    Oceanic heat capacity of the upper layer is a key of the change in the sea surface temperature (SST) affecting air-sea heat exchange and of the temporal scale of SST variability. In the past, studies of SST variability associated with the air-sea heat exchange have mainly focused on the conditions during the winter, because wintertime deep mixed layer (ML) accumulates a huge amount of heat to the atmosphere. On the contrary, ML during the warming season is thinner than it is during the cooling season, being only a few tens of meters deep at mid- and high- latitudes, bounded by a shallow and sharp seasonal thermocline. Since the ML that directly communicates with the atmosphere is thin, the ocean has been considered to play a passive role in air-sea interactions during the warming season. In this study, we clarified that subsurface ocean plays an important role to seasonal changes of SST and heat capacity during the warming season using observational data of Argo and J-OFURO2, which is net heat flux (Qnet) data from satellites. To clarify the role of upper ocean to the Qnet during summer, we introduce a concept of heat penetration depth (HPD), defined as the depth to which Qnet distinctly penetrates below the seasonal thermocline. Then we assume vertical one dimensional process between Qnet and temporal heat content (HC) change integrating temperature from surface to HPD. The vertical one dimensional process can be assumed in almost mid- and high-latitude NP, and we successfully characterize the heat capacity in terms of the HC above the HPD. The downward heat penetration below the shallow seasonal thermocline is widely found throughout the NP. On the basis of a simple estimation that the amount of heat accumulated by summer Qnet in the NP, about two-thirds of Qnet penetrates below the shallow seasonal thermocline. The effect of heat penetration also makes a magnitude of seasonal change in SST to be smaller, at least a half of that the magnitude under the assumption

  7. Multiscale computational modeling of a radiantly driven solar thermal collector

    Science.gov (United States)

    Ponnuru, Koushik

    The objectives of the master's thesis are to present, discuss and apply sequential multiscale modeling that combines analytical, numerical (finite element-based) and computational fluid dynamic (CFD) analysis to assist in the development of a radiantly driven macroscale solar thermal collector for energy harvesting. The solar thermal collector is a novel green energy system that converts solar energy to heat and utilizes dry air as a working heat transfer fluid (HTF). This energy system has important advantages over competitive technologies: it is self-contained (no energy sources are needed), there are no moving parts, no oil or supplementary fluids are needed and it is environmentally friendly since it is powered by solar radiation. This work focuses on the development of multi-physics and multiscale models for predicting the performance of the solar thermal collector. Model construction and validation is organized around three distinct and complementary levels. The first level involves an analytical analysis of the thermal transpiration phenomenon and models for predicting the associated mass flow pumping that occurs in an aerogel membrane in the presence of a large thermal gradient. Within the aerogel, a combination of convection, conduction and radiation occurs simultaneously in a domain where the pore size is comparable to the mean free path of the gas molecules. CFD modeling of thermal transpiration is not possible because all the available commercial CFD codes solve the Navier Stokes equations only for continuum flow, which is based on the assumption that the net molecular mass diffusion is zero. However, thermal transpiration occurs in a flow regime where a non-zero net molecular mass diffusion exists. Thus these effects are modeled by using Sharipov's [2] analytical expression for gas flow characterized by high Knudsen number. The second level uses a detailed CFD model solving Navier Stokes equations for momentum, heat and mass transfer in the various

  8. The theory of heat radiation

    CERN Document Server

    Planck, Max

    2003-01-01

    Nobel laureate's classic exposition of the theory of radiant heat in terms of quantum action. Kirchoff's law, black radiation, Maxwell's radiation pressure, entropy, other topics. 1914 edition. Bibliography.

  9. Sub-canopy radiant energy during snowmelt in non-uniform forests spanning a latitudinal transect

    Science.gov (United States)

    Link, T. E.; Essery, R.; Marks, D.; Pomeroy, J.; Hardy, J.; Sicart, J. E.

    2008-12-01

    In mountainous, forested environments, snowcover dynamics exert a strong control on hydrologic and atmospheric processes. Snowcover ablation patterns in forests are controlled by a complex combination of depositional patterns coupled with radiative and turbulent heat flux patterns related to topographic and canopy cover variations. Quantification of small-scale variations of radiant energy in forested environments is necessary to understand how canopy structure affects snowcover energetics to improve the representation of snowmelt processes in spatially-explicit physically-based snowmelt models. Incoming solar and thermal radiation were measured during the melt season within continuous and discontinuous forest stands, and at the interface between forest patches and small clearings along a transect spanning the North American Cordillera. Results indicate that reductions in solar radiation at the snow surface are partially balanced by increased thermal radiation from the forest canopy, relative to open locations. The differences between the transfer processes for solar and thermal radiation can produce two net incoming and net snowcover radiation paradoxes in heterogeneous environments. In discontinuous canopies, net radiation in forested areas may exceed radiation in open sites, whereas in other situations, net radiation may be less than net radiation in closed canopy forests. The empirical results coupled with theoretical modeling indicates that the effects of forest canopies on the radiative regimes at the snow surface are controlled by complex interactions of slope, aspect, gap sizes, canopy height, canopy density, canopy temperature, snow surface temperature and snowcover albedo. In higher latitude, closed canopy forests, radiative regimes may be characterized by relatively simple geometric optical radiation transfer methods, whereas at lower latitude and more non- uniform forests, other processes such as canopy and stem heating must be considered. These net

  10. Prototyping Energy Efficient Thermo-Magnetic & Induction Hardening for Heat Treat & Net Shape Forming Applications

    Energy Technology Data Exchange (ETDEWEB)

    Aquil Ahmad

    2012-08-03

    Within this project, Eaton undertook the task of bringing about significant impact with respect to sustainability. One of the major goals for the Department of Energy is to achieve energy savings with a corresponding reduction in carbon foot print. The use of a coupled induction heat treatment with high magnetic field heat treatment makes possible not only improved performance alloys, but with faster processing times and lower processing energy, as well. With this technology, substitution of lower cost alloys for more exotic alloys became a possibility; microstructure could be tailored for improved magnetic properties or wear resistance or mechanical performance, as needed. A prototype commercial unit has been developed to conduct processing of materials. Testing of this equipment has been conducted and results demonstrate the feasibility for industrial commercialization.

  11. Solar Sustainable Heating, Cooling and Ventilation of a Net Zero Energy House

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Skrupskelis, Martynas; Olesen, Bjarne W.

    Present work addresses the heating, cooling and ventilation concerns of the Technical University of Denmark’s house, Fold, for Solar Decathlon Europe 2012. Various innovative approaches are investigated, namely, utilization of ground, photo-voltaic/thermal (PV/T) panels and phase change materials...... by the embedded pipes which are coupled with the ground. Ventilation is mainly used to control the humidity and to remove sensory and chemical pollution. PV/T panels enable the house to be a “plus” energy house. PV/T also yields to a solar fraction of 63% and 31% for Madrid and Copenhagen, respectively...

  12. Thermal environment in a simulated double office room with convective and radiant cooling systems

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Rezgals, Lauris

    2017-01-01

    The thermal environment in a double office room obtained with chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and overhead mixing total volume ventilation (MTVV) under summer (cooling) condition was compared. Design (peak......) and usual (average) heat load from solar radiation, office equipment, lighting and occupants was simulated, respectively at 62 W/m2 and 38 W/m2 under four different workstation layouts. Air temperature, globe (operative) temperature, radiant asymmetry, air velocity and turbulent intensity were measured...

  13. Energy efficient heating and ventilation of large halls

    CERN Document Server

    Hojer, Ondrej; Kabele, Karel; Kotrbaty, Miroslav; Sommer, Klaus; Petras, Dusan

    2011-01-01

    This guidebook is focused on modern methods for design, control and operation of energy efficient heating systems in large spaces and industrial halls. The book deals with thermal comfort, light and dark gas radiant heaters, panel radiant heating, floor heating and industrial air heating systems. Various heating systems are illustrated with case studies. Design principles, methods and modeling tools are presented for various systems.

  14. Evaluation of Heat Stress in the working position 60 of furnace workers in one of the forging industries in the summer

    Directory of Open Access Journals (Sweden)

    2012-03-01

    Conclusion: Heat stress in workers exposed to the radiant heat sources were higher than the Threshold limit value, which recommended by ACGIH. The results also indicated that the main problem were the radiant heat, especially in the head and waist height. Hence in order to decrease the radiant heat, some control solutions were Suggested.

  15. NOy production, ozone loss and changes in net radiative heating due to energetic particle precipitation in 2002–2010

    Directory of Open Access Journals (Sweden)

    M. Sinnhuber

    2018-01-01

    Full Text Available We analyze the impact of energetic particle precipitation on the stratospheric nitrogen budget, ozone abundances and net radiative heating using results from three global chemistry-climate models considering solar protons and geomagnetic forcing due to auroral or radiation belt electrons. Two of the models cover the atmosphere up to the lower thermosphere, the source region of auroral NO production. Geomagnetic forcing in these models is included by prescribed ionization rates. One model reaches up to about 80 km, and geomagnetic forcing is included by applying an upper boundary condition of auroral NO mixing ratios parameterized as a function of geomagnetic activity. Despite the differences in the implementation of the particle effect, the resulting modeled NOy in the upper mesosphere agrees well between all three models, demonstrating that geomagnetic forcing is represented in a consistent way either by prescribing ionization rates or by prescribing NOy at the model top.Compared with observations of stratospheric and mesospheric NOy from the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS instrument for the years 2002–2010, the model simulations reproduce the spatial pattern and temporal evolution well. However, after strong sudden stratospheric warmings, particle-induced NOy is underestimated by both high-top models, and after the solar proton event in October 2003, NOy is overestimated by all three models. Model results indicate that the large solar proton event in October 2003 contributed about 1–2 Gmol (109 mol NOy per hemisphere to the stratospheric NOy budget, while downwelling of auroral NOx from the upper mesosphere and lower thermosphere contributes up to 4 Gmol NOy. Accumulation over time leads to a constant particle-induced background of about 0.5–1 Gmol per hemisphere during solar minimum, and up to 2 Gmol per hemisphere during solar maximum. Related negative anomalies of ozone are predicted by

  16. A Simulation Study on the Performance of Radiant Ceilings Combined with Free-Hanging Horizontal Sound Absorbers

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Domínguez, L. Marcos; Rage, Niels

    2018-01-01

    Radiant heating and cooling systems, and Thermally Active Building Systems (TABS) in particular, have several advantages such as benefiting from the low temperature heating and high temperature cooling principle, coupling with renewable energy sources, peak shifting and peak load reductions. When...

  17. Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2010-01-01

    The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems...... is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly...... calculate the magnitude of the Direct Solar Load in cooling load calculations is proposed and it is implemented with the Heat Balance method and the Radiant Time Series method. The F ratio of the solar heat gains directly converted to cooling load, in the case of a low thermal mass radiant ceiling...

  18. A full-scale experimental set-up for assessing the energy performance of radiant wall and active chilled beam for cooling buildings

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2015-01-01

    Full-scale experiments under both steady-state and dynamic conditions have been performed to compare the energy performance of a radiant wall and an active chilled beam. From these experiments, it has been observed that the radiant wall is a more secure and efficient way of removing heat from...... the test room than the active chilled beam. The energy saving, which can be estimated to around 10%, is due to increased ventilation losses. The asymmetry between air and radiant temperature, the air temperature gradient and the possible short-circuit between inlet and outlet play an equally important role...... in decreasing the cooling need of the radiant wall compared to the active chilled beam. It has also been observed that the type and repartition of heat load have an influence on the cooling demand. Regarding the comfort level, both terminals met the general requirements, except at high solar heat gains...

  19. Effects of cryogen spray cooling and high radiant exposures on selective vascular injury during laser irradiation of human skin.

    Science.gov (United States)

    Tunnell, James W; Chang, David W; Johnston, Carol; Torres, Jorge H; Patrick, Charles W; Miller, Michael J; Thomsen, Sharon L; Anvari, Bahman

    2003-06-01

    Increasing radiant exposure offers a means to increase treatment efficacy during laser-mediated treatment of vascular lesions, such as port-wine stains; however, excessive radiant exposure decreases selective vascular injury due to increased heat generation within the epidermis and collateral damage to perivascular collagen. To determine if cryogen spray cooling could be used to maintain selective vascular injury (ie, prevent epidermal and perivascular collagen damage) when using high radiant exposures (16-30 J/cm2). Observational study. Academic hospital and research laboratory. Twenty women with normal abdominal skin (skin phototypes I-VI). Skin was irradiated with a pulsed dye laser (wavelength = 585 nm; pulse duration = 1.5 milliseconds; 5-mm-diameter spot) using various radiant exposures (8-30 J/cm2) without and with cryogen spray cooling (50- to 300-millisecond cryogen spurts). Hematoxylin-eosin-stained histologic sections from each irradiated site were examined for the degree of epidermal damage, maximum depth of red blood cell coagulation, and percentage of vessels containing perivascular collagen coagulation. Long cryogen spurt durations (>200 milliseconds) protected the epidermis in light-skinned individuals (skin phototypes I-IV) at the highest radiant exposure (30 J/cm2); however, epidermal protection could not be achieved in dark-skinned individuals (skin phototypes V-VI) even at the lowest radiant exposure (8 J/cm2). The red blood cell coagulation depth increased with increasing radiant exposure (to >2.5 mm for skin phototypes I-IV and to approximately 1.2 mm for skin phototypes V-VI). In addition, long cryogen spurt durations (>200 milliseconds) prevented perivascular collagen coagulation in all skin types. Cryogen spurt durations much longer than those currently used in therapy (>200 milliseconds) may be clinically useful for protecting the epidermis and perivascular tissues when using high radiant exposures during cutaneous laser therapies

  20. Radiant-and-plasma technology for coal processing

    Directory of Open Access Journals (Sweden)

    Vladimir Messerle

    2012-12-01

    Full Text Available Radiant-and-plasma technology for coal processing is presented in the article. Thermodynamic computation and experiments on plasma processing of bituminous coal preliminary electron-beam activated were fulfilled in comparison with plasma processing of the coal. Positive influence of the preliminary electron-beam activation of coal on synthesis gas yield was found. Experiments were carried out in the plasma gasifier of 100 kW power. As a result of the measurements of material and heat balance of the process gave the following integral indicators: weight-average temperature of 2200-2300 K, and carbon gasification degree of 82,4-83,2%. Synthesis gas yield at thermochemical preparation of raw coal dust for burning was 24,5% and in the case of electron-beam activation of coal synthesis gas yield reached 36,4%, which is 48% higher.

  1. Experimental characterization of a radiant porous burner for low temperatures using natural gas; Caracterizacao experimental de um queimador poroso radiante a gas natural para baixas temperaturas

    Energy Technology Data Exchange (ETDEWEB)

    Catapan, Rafael C.; Hissanaga, Newton Junior; Pereira, Fernando M.; Oliveira Junior, Amir A.M. de [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica; Serfaty, Ricardo [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES); Freire, Luiz G.M. [PETROBRAS - RedeGasEnergia, RJ (Brazil)

    2004-07-01

    This article describes the experimental characterization of a radiant porous burner for temperatures between 500 deg C and 900 deg C. These low temperature radiant burners can be used in many practical applications as drying of paper and wood, plastic coating, food cooking and ambient heating. Two different configurations of silicon carbide porous ceramic foams were tested: one with a radian reflecting region (RRR) at the outlet and another without this region. Both configurations were able to sustain the reaction with equivalent ratio under 0,35. The configuration with a reflecting region was able to sustain flames with a minimum power of 60 kW/m{sup 2} and the other configuration with 100 W/m{sup 2}.The configuration with the RRR reached minimum superficial temperatures about 100 deg C lower than the other one. These results show that the reflecting region increases the heat recirculation inside the porous burner. The radiant efficiency varied from 20% to 35% for both burners. (author)

  2. A RADIANT AIR-CONDITIONING SYSTEM USING SOLAR-DRIVEN

    Directory of Open Access Journals (Sweden)

    S. A. ABDALLA

    2006-12-01

    Full Text Available Every air-conditioning system needs some fresh air to provide adequate ventilation air required to remove moisture, gases like ammonia and hydrogen sulphide, disease organisms, and heat from occupied spaces. However, natural ventilation is difficult to control because urban areas outside air is often polluted and cannot be supplied to inner spaces before being filtered. Besides the high electrical demand of refrigerant compression units used by most air-conditioning systems, and fans used to transport the cool air through the thermal distribution system draw a significant amount of electrical energy in comparison with electrical energy used by the building thermal conditioning systems. Part of this electricity heats the cooled air; thereby add to the internal thermal cooling peak load. In addition, refrigerant compression has both direct and indirect negative effects on the environment on both local and global scales. In seeking for innovative air-conditioning systems that maintain and improve indoor air quality under potentially more demanding performance criteria without increasing environmental impact, this paper presents radiant air-conditioning system which uses a solar-driven liquid desiccant evaporative cooler. The paper describes the proposed solar-driven liquid desiccant evaporative cooling system and the method used for investigating its performance in providing cold water for a radiant air-conditioning system in Khartoum (Central Sudan. The results of the investigation show that the system can operate in humid as well as dry climates and that employing such a system reduces air-conditioning peak electrical demands as compared to vapour compression systems.

  3. Development of a unified sizing method for gas radiation heating facilities used in large-volume buildings; Developpement d'une methode de dimensionnement unifiee d'installations de chauffage radiant gaz pour les batiments de grand volume

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, M.; Bego, L.; Douls, Y.; Le Dean, P.; Paradowski, V. [Gaz de France, GDF, Dir. de la Recherche, 75 - Paris (France)

    2000-07-01

    Builders now have perfect command of the natural gas heating technique used for large-volume buildings. However, the sizing of heating facilities still leaves grounds for discussion, whatever the energies actually used. Accordingly, between 1997 and 1999, the ATG (technical association of the Gas industry in France), seven French manufacturers of 'large volume' heating equipment, the Chaleur Et Rayonnement (CER) association and Gaz de France decided to collaborate and develop a 'unified sizing method' for heating facilities using radiating emitters. During the first year of the study, the above partners worked on the said method (theoretical thermal study of the radiative phenomena, and then adaptation to the methods currently used by the various manufacturers). In 1998, with the support of the ADEME (the French environment and energy control agency), the partners tested the method on five industrial buildings (studying the thermal behavior and making air renewal measurements with search gases). This work made it possible to either confirm or adapt the theoretical evaluations which had been made originally. In 1999, a software program was produced to make the developed method more user friendly. The program can be used to determine the power to be installed, but also to assess the quality of the chosen configuration of the emitters (unit power, inclination, orientation) for optimum customer comfort. (authors)

  4. Tingkat Insidensi Malaria di Wilayah Pemanasan Kelambu Berinsektisida Tahan Lama dan Wilayah Kontrol (MALARIA INCIDENCE RATE OF HEAT ASSISTED REGENERATION LONG LASTING INSECTICIDAL NETS AREA AND CONTROL

    Directory of Open Access Journals (Sweden)

    Etih Sudarnika

    2012-03-01

    Full Text Available Long lasting insecticidal nets (LLIN is one effective way to prevent malaria. Permethrin treatedLLIN is one type of LLIN which is recommended by WHO. Several studies have shown that these types ofLLIN requiring heat assisted regeneration after washing to enhance the biological activity of insecticidethat contained in the LLIN fibers. This study aimed to compare the incidence rates of malaria in childrenunder five years old who live in the intervention area (where the heat assisted regeneration on LLIN afterwashing was applied and control area (where the heat assisted regeneration on LLIN after washing wasnot applied. Data of malaria cases was collected from laboratory log book at all health centers in BangkaDistrict, in the period of June June 2007 until July 2008. Data were analyzed with Poisson regressionmodels. The results showed that the incidence rate of malaria in children under five years old was notsignificantly different between the treatment and control areas.

  5. Application of roof radiant burners in large pusher-type furnaces

    Directory of Open Access Journals (Sweden)

    A. Varga

    2009-07-01

    Full Text Available The paper deals with the application of roof flat-flame burners in the pusher-type steel slab reheating furnaces, after furnace reconstruction and replacement of conventional torch burners, with the objective to increase the efficiency of radiative heat transfer from the refractory roof to the charge. Based on observations and on measurements of the construction and process parameters under operating conditions, the advantages and disadvantages of indirectly oriented radiant heat transfer are analysed in relation to the heat transfer in classically fired furnaces.

  6. Comparison of radiant and convective cooling of office room: effect of workstation layout

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Rezgals, Lauris

    2014-01-01

    The impact of heat source location (room layout) on the thermal environment generated in a double office room with four cooling ventilation systems - overhead ventilation, chilled ceiling with overhead ventilation, active chilled beam and active chilled beam with radiant panels was measured...... and compared. The room was furnished with two workstations, two laptops and two thermal manikins resembling occupants. Two heat load levels, design (65 W/m2) and usual (39 W/m2), were generated by adding heat from warm panels simulating solar radiation. Two set-ups were studied: occupants sitting...

  7. Effect of aluminized fabrics on radiant protective performance of fire proximity suit materials.

    Science.gov (United States)

    Jin, Lu; Park, Pyoung Kyu; Hong, Kyoung A; Yoon, Kee Jong

    2015-03-01

    Radiant heat may be a significant component of heat exposure in the case of proximity firefighting. To combat high levels of radiant heat, fire proximity suits made of aluminized fabrics (Al-Fb) are commonly used due to their proven radiant protective performance (RPP). In this study RPP of various Al-Fb prepared using different aluminized films (Al-Fl) such as double-sided aluminized film and single-sided aluminized film and different base fabrics such as woven, knit, and nonwoven fabrics are compared. The effect of flexing on RPP and flame protective performance (FPP) of Al-Fb is also examined. The results show that RPP of Al-Fl is affected by the protective film to protect against mechanical or physical damages, and also by their structure such as whether the second reflective aluminum layer is present or not. In addition RPP of Al-Fb is also influenced by the base fabric, especially its surface roughness. The increased surface roughness combined with the damage caused to the aluminum layer after flexing result in reduction of RPP of Al-Fb. The contribution of Al-Fl to FPP of Al-Fb is not as significant as to RPP. Finally, based on the results, some points that may be important in developing and designing fire proximity suits are recommended. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  8. Development of a non-premixed radiant burner. Experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, P.; Myken, A.N.; Rasmussen, N.B.

    1997-12-31

    The objective was to develop and test a non-premixed radiant burner. A burner concept, pro-type 1, was developed with special attention to minimise emissions and foam peak-temperatures. During the test of the prototype it became evident that the construction was not feasible, because the ceramic gas distribution tubes eventually were blocked by soot. Experiments to investigate if the gas would crack conducted prior to the construction of the burner did not indicate that any problems would occur. It can therefore be concluded that the experiments did not simulate burner conditions adequately. Alternative prototypes in which the gas is not heated prior to injection into the combustion chamber have been established. The concept operated satisfactorily without preheating of the combustion air, although NO{sub x}-emissions were high. The measured process efficiencies were superior to previous results for different kinds of surface burners. When the combustion air was preheated to 400 deg. C, the foam sections broke down. The experimental results can be summarised in the following conclusions: The developed prototypes can not be operated with combustion air preheated to 400 deg. C or higher; A relative improvement of the process efficiency by 22% has been observed when the combustion air is preheated to 400 deg. C; The NO{sub x}-emissions increase significantly and much more than the process efficiency when the combustion air is preheated; The process efficiency obtained with prototype 5 is better than previously investigated surface burners, especially at high loads. Possible means to improve durability, efficiency and emission level for both burner concepts are suggested. These include cooling of the gas in prototype 1, coating of the downstream side of the foam section to improve the radiant efficiency and multistep combustion. (EHS)

  9. Annual Performance of a Two-Speed, Dedicated Dehumidification Heat Pump in the NIST Net-Zero Energy Residential Test Facility.

    Science.gov (United States)

    Payne, W Vance

    2016-01-01

    A 2715 ft2 (252 m2), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft-2, 51.7 kWh m-2), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft-2, 24.7 kWh m-2) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W-1h-1 (2.95 W W-1), relative to the rated SEER of the heat pump of 15.8 Btu W-1h-1 (4.63 W W-1). Annual heating efficiency was 7.10 Btu W-1h-1 (2.09 W W-1), compared with the unit's rated HSPF of 9.05 Btu W-1h-1 (2.65 W W-1). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively.

  10. Radiant Energy Power Source for Jet Aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Doellner, O.L.

    1992-02-01

    This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

  11. An optimization methodology for the design of renewable energy systems for residential net zero energy buildings with on-site heat production

    DEFF Research Database (Denmark)

    Milan, Christian; Bojesen, Carsten; Nielsen, Mads Pagh

    2011-01-01

    energy supply systems for residential NZEB involving on-site production of heat and electricity in combination with electricity exchanged with the public grid. The model is based on linear programming and determines the optimal capacities for each relevant supply technology in terms of the overall system......The concept of net zero energy buildings (NZEB) has received increased attention throughout the last years. A well adapted and optimized design of the energy supply system is crucial for the performance of such buildings. This paper aims at developing a method for the optimal sizing of renewable...

  12. SolNet

    DEFF Research Database (Denmark)

    Jordan, Ulrike; Vajen, Klaus; Bales, Chris

    2014-01-01

    SolNet, founded in 2006, is the first coordinated International PhD education program on Solar Thermal Engineering. The SolNet network is coordinated by the Institute of Thermal Engineering at Kassel University, Germany. The network offers PhD courses on solar heating and cooling, conference...

  13. Vaporization, dispersion, and radiant fluxes from LPG spills. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    1982-05-01

    Both burning and non-burning spills of LPG (primarily propane) were studied. Vaporization rates for propane spills on soil, concrete, insulating concrete, asphalt, sod, wood, and polymer foams were measured. Thermal conductivity, heat transfer coefficients, and steady state vaporization rates were determined. Vapor concentrations were measured downwind of open propane pools and a Gaussian dispersion model modified for area sources provided a good correlation of measured concentrations. Emitted and incident radiant fluxes from propane fires were measured. Simplified flame radiation models were adequate for predicting radiant fluxes. Tests in which propane was sprayed into the air showed that at moderately high spray rates all the propane flashed to vapor or atomized; no liquid collected on the ground.

  14. Radiant Floor Cooling Combined with Mixing Ventilation in a Residential Room

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Tomasi, Roberta

    and by thermal manikin equivalent temperatures. Contaminant removal effectiveness and air change efficiency were used to characterize the ventilation effectiveness. The vertical air temperature differences that occurred when floor cooling was combined with cold conditioned air supply were well within the limits...... for comfortable thermal environment recommended by the standards. The cooler supply air mixed well and the effect of the position of air terminal devices was small. When warm unconditioned outside air was supplied by mixing ventilation in combination with the radiant floor cooling, low floor temperature......Mixing air ventilation system is one of the main ventilation concepts applied in residential buildings. The effect of combining the mixing ventilation system with the radiant floor heating has been well established, whereas the validation of using the floor for cooling in summer is still...

  15. Effects of radiant temperature on thermal comfort

    Energy Technology Data Exchange (ETDEWEB)

    Atmaca, Ibrahim; Kaynakli, Omer; Yigit, Abdulvahap [Uludag University, Bursa (Turkey). Faculty of Engineering and Architecture, Department of Mechanical Engineering

    2007-09-15

    The aim of this paper is to investigate the local differences between body segments caused by high radiant temperature, and to analyze the interior surface temperatures for different wall and ceiling constructions with their effect on thermal comfort. For the segment-wise thermal interactions between human body and its surrounding, simulations have been conducted by appropriately modifying Gagge 2-node model to multi-segment case to demonstrate the local differences. Simulation results are found to be in good agreement with experimental and simulation results reported in the literature. To calculate the interior surface temperatures of the wall and ceiling, the sol-air temperature approach is used for convenience. It is shown in the paper that the body segments close the relatively hot surfaces are more affected than others and interior surface temperatures of un-insulated walls and ceilings exposed to a strong solar radiation reach high levels, all of which cause thermal discomfort for the occupants in buildings. (author)

  16. Study on a mean radiant temperature measure tool based on an almost spherical array of radiometric sensors.

    Science.gov (United States)

    Fontana, L

    2012-11-01

    Mean radiant temperature has significant influence on indoor thermal comfort conditions. It has gained greater importance with the wider application of heating and cooling systems based on the use of large surfaces with a temperature slightly higher or lower than the indoor temperature (hot/cold floors or ceilings), because these systems operate through the radiant temperature control. The most used tool to measure radiant temperature, the globe thermometer, still has large margins of error, most of all due to the uncertainty in the evaluation of the convection heat exchanges between the globe surface and the indoor air. The feasibility of a device to measure mean radiant temperature in indoor condition, alternative to the globe-thermometer (obtained placing radiometric sensors (thermopiles) on the sides of different geometric regular solids), is proposed. The behavior has been investigated for different regular solids, such as the residual error and its dependence on walls average temperature, non-uniformity magnitude, orientation and position of the solid in the enclosure, room shape, non-uniformity temperature distribution. Icosahedron shape shows an excellent behavior, with errors lower than 0.1 K in all the examined conditions.

  17. Radiant Ceiling Panels Combined with Localized Methods for Improved Thermal Comfort of Both Patient and Medical Staff in Patient Room

    DEFF Research Database (Denmark)

    Mori, Sakura; Barova, Mariya; Bolashikov, Zhecho Dimitrov

    2012-01-01

    The objectives were to identify whether ceiling installed radiant heating panels can provide thermal comfort to the occupants in a patient room, and to determine a method for optimal thermal environment to both patient and medical staff simultaneously. The experiments were performed in a climate...... chamber resembling a single-bed patient room under convective air conditioning alone or combined with the ceiling installed radiant heating panels. Two thermal manikins simulated a patient lying in the bed and a doctor standing next to the patient. Conventional cotton blanket, electric blanket, electric...... mattress were used to provide local heating for the patient. The effects of the methods were identified by comparing the manikin based equivalent temperatures. The optimal thermal comfort level for both patient and medical staff would obtained when two conventional cotton blankets were used with extra...

  18. Radiant Heat Test Facility (RHTF): User Test Planning Guide

    Science.gov (United States)

    DelPapa, Steven

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the RHTF. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  19. Ten questions about radiant heating and cooling systems

    DEFF Research Database (Denmark)

    Rhee, Kyu-Nam; Olesen, Bjarne W.; Kim, Kwang Woo

    2017-01-01

    to extend the applicability of the RHC system are providing the continuous impetus for research on RHC systems. This paper summarizes the important issues involved in the research on RHC system, whereby ten questions and answers concerning the RHC system are discussed, which will help researchers to conduct...

  20. Cooling load calculation by the radiant time series method - effect of solar radiation models

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Alexandre M.S. [Universidade Estadual de Maringa (UEM), PR (Brazil)], E-mail: amscosta@uem.br

    2010-07-01

    In this work was analyzed numerically the effect of three different models for solar radiation on the cooling load calculated by the radiant time series' method. The solar radiation models implemented were clear sky, isotropic sky and anisotropic sky. The radiant time series' method (RTS) was proposed by ASHRAE (2001) for replacing the classical methods of cooling load calculation, such as TETD/TA. The method is based on computing the effect of space thermal energy storage on the instantaneous cooling load. The computing is carried out by splitting the heat gain components in convective and radiant parts. Following the radiant part is transformed using time series, which coefficients are a function of the construction type and heat gain (solar or non-solar). The transformed result is added to the convective part, giving the instantaneous cooling load. The method was applied for investigate the influence for an example room. The location used was - 23 degree S and 51 degree W and the day was 21 of January, a typical summer day in the southern hemisphere. The room was composed of two vertical walls with windows exposed to outdoors with azimuth angles equals to west and east directions. The output of the different models of solar radiation for the two walls in terms of direct and diffuse components as well heat gains were investigated. It was verified that the clear sky exhibited the less conservative (higher values) for the direct component of solar radiation, with the opposite trend for the diffuse component. For the heat gain, the clear sky gives the higher values, three times higher for the peek hours than the other models. Both isotropic and anisotropic models predicted similar magnitude for the heat gain. The same behavior was also verified for the cooling load. The effect of room thermal inertia was decreasing the cooling load during the peak hours. On the other hand the higher thermal inertia values are the greater for the non peak hours. The effect

  1. Effects of Floor Covering Resistance of a Radiant Floor on System Energy and Exergy Performances

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    performance, a water-based radiant floor heating and cooling system (dry, wooden construction) was considered to be coupled to an air-to-water heat pump, and the effects of varying floor covering resistances (0.05 m2K/W, 0.09 m2K/W and 0.15 m2K/W) on system performance were analyzed in terms of energy...... coefficient of performance). This requires higher electricity input to the heat pump, corresponding to an increased exergy demand and consumption, to achieve the same space heating or cooling. The required exergy input to the system (power plant where the electricity is generated) increased by 14% and 5...

  2. Clouds and the Earth's Radiant Energy System (CERES)

    Data.gov (United States)

    National Aeronautics and Space Administration — The Clouds and the Earth's Radiant Energy System (CERES) is a key component of the Earth Observing System (EOS) program. The CERES instruments provide radiometric...

  3. Use of local convective and radiant cooling at warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2012-01-01

    The effect of four local cooling devices (convective, radiant and combined) on SBS symptoms reported by 24 subjects at 28 ˚C and 50% RH was studied. The devices studied were: (1) desk cooling fan, (2) personalized ventilation providing clean air, (3) two radiant panels and (4) two radiant panels....... The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The minimal improvement in PAQ was reported when the radiant...... with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (p

  4. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  5. Validation of the uncertainty budget for soft X-ray radiant power measurement using a cryogenic radiometer

    CERN Document Server

    Rabus, H; Scholze, F; Thornagel, R; Ulm, G

    2002-01-01

    The cryogenic radiometer SYRES, a thermal detector based on the electrical substitution principle, has been used as the primary detector standard for radiant power measurement in the ultraviolet, vacuum ultraviolet and soft X-ray spectral ranges. In order to investigate the possibility of radiant energy being deposited in its absorber cavity without being transformed into heat when detecting soft X-rays, SYRES has been directly compared with the electron storage ring BESSY 1, a primary radiometric source standard of calculable spectral radiant power. To this end, the integral radiant power emitted by the storage ring,into a solid angle defined by a high-precision aperture was measured with SYRES. The experiments were conducted at two nominal energies of the circulating electrons, 800 MeV and 340 MeV, to study the influence of the different spectral distributions of the synchrotron radiation. For the original graphite-coated cavity absorber, significant discrepancies were found which could be traced back to th...

  6. Global Surface Net-Radiation at 5 km from MODIS Terra

    Directory of Open Access Journals (Sweden)

    Manish Verma

    2016-09-01

    Full Text Available Reliable and fine resolution estimates of surface net-radiation are required for estimating latent and sensible heat fluxes between the land surface and the atmosphere. However, currently, fine resolution estimates of net-radiation are not available and consequently it is challenging to develop multi-year estimates of evapotranspiration at scales that can capture land surface heterogeneity and are relevant for policy and decision-making. We developed and evaluated a global net-radiation product at 5 km and 8-day resolution by combining mutually consistent atmosphere and land data from the Moderate Resolution Imaging Spectroradiometer (MODIS on board Terra. Comparison with net-radiation measurements from 154 globally distributed sites (414 site-years from the FLUXNET and Surface Radiation budget network (SURFRAD showed that the net-radiation product agreed well with measurements across seasons and climate types in the extratropics (Wilmott’s index ranged from 0.74 for boreal to 0.63 for Mediterranean sites. Mean absolute deviation between the MODIS and measured net-radiation ranged from 38.0 ± 1.8 W∙m−2 in boreal to 72.0 ± 4.1 W∙m−2 in the tropical climates. The mean bias was small and constituted only 11%, 0.7%, 8.4%, 4.2%, 13.3%, and 5.4% of the mean absolute error in daytime net-radiation in boreal, Mediterranean, temperate-continental, temperate, semi-arid, and tropical climate, respectively. To assess the accuracy of the broader spatiotemporal patterns, we upscaled error-quantified MODIS net-radiation and compared it with the net-radiation estimates from the coarse spatial (1° × 1° but high temporal resolution gridded net-radiation product from the Clouds and Earth’s Radiant Energy System (CERES. Our estimates agreed closely with the net-radiation estimates from the CERES. Difference between the two was less than 10 W·m−2 in 94% of the total land area. MODIS net-radiation product will be a valuable resource for the

  7. Using the Synergy Between GERB/SEVIRI and Micrometeorological Data to Study the Relationship Between Surface Net Radiation and Soil Heat Flux at Local and Regional Scales

    Science.gov (United States)

    Ferreira, A. G.; Velázquez Blázquez, A.; Soria, E.; Lopez-Baeza, E.

    2009-04-01

    The surface energy exchange between the land surface and the atmosphere can be described by the energy balance equation Rn - H - LE - G = 0, where Rn represents net radiation, H the sensible heat flux, LE, the latent heat flux and G the soil heat flux. In this work the relationship between Rn and G is studied over vineyard crops, a relative sparse vegetation cover crop where, according to the literature, it is expected that G consumes a significant proportion of Rn. In order to study this relationship at local and regional scales, micrometeorological observations and METEOSAT Second Generation (MSG) satellite data have been used. MSG through the GERB (Geostationary Earth Radiation Budget) and the SEVIRI (Spinning Enhanced Visible and Infrared Imager) sensors can provide estimates of net radiation and required land surface temperature (LST) information with a frequency of 15 min intervals. The necessary micrometeorological parameters, to compare with satellite data, were collected during the full vine growing season of 2007 (May to September) in a field experiment carried out at the Valencia Anchor Station (VAS) site area. The VAS is a robust reference meteorological station which is successfully used preferentially for validation of low spatial resolution satellite data and products. It is located on the natural region of the Utiel-Requena Plateau, at about 80 km west from the city of Valencia, Spain, and represents a reasonable homogeneous area of about 50 km x 50 km dedicated primarily to growing vines. The methodology utilized to study the relationship between Rn and G at local and regional scales, was that proposed by Santanello and Friedel (2002), where surface temperature can be obtained from SEVIRI that provides estimates of LST with unprecedented frequency of 15 min intervals with a spatial resolution of 3.1 km, thus totally covering its diurnal course. The preliminary results show that: 1- the correlation between the ground measurements and SEVIRI LST is

  8. Thermal Comfort in Simulated Office Environment with Four Convective and Radiant Cooling Systems

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Mustakallio, Panu; Kolencíková, Sona

    2013-01-01

    Experiments with 24 human subjects in a simulated office with four cooling systems were performed. The systems were: chilled beam (CB), chilled beam with integrated radiant panel (CBR), chilled ceiling with overhead mixing ventilation (CCMV) and four desk partition mounted radiant cooling panels...... with overhead mixing ventilation (MVRC). Whole body thermal sensation (TS) and whole body TS acceptability under the four systems in a simulated office room for one hour exposure were collected. The simulated two-man office (4.12 x 4.20 x 2.89 m, L x W x H) was kept at 26 oC room air temperature. Moderate heat...... load of 64 W/m2 was generated by simulated solar heat load, 2 laptops and 2 occupants, giving in total 1104 W. The supplied outdoor air temperature was kept at 16 oC. The supply air flow rate for CB, CBR and CCMV was set to 26 L/s (category II low-polluting building, EN 15251-2007). For MVRC supply...

  9. Net Locality

    DEFF Research Database (Denmark)

    de Souza e Silva, Adriana Araujo; Gordon, Eric

    Provides an introduction to the new theory of Net Locality and the profound effect on individuals and societies when everything is located or locatable. Describes net locality as an emerging form of location awareness central to all aspects of digital media, from mobile phones, to Google Maps...... of emerging technologies, from GeoCities to GPS, Wi-Fi, Wiki Me, and Google Android....

  10. Net Neutrality

    DEFF Research Database (Denmark)

    Savin, Andrej

    2017-01-01

    Repealing “net neutrality” in the US will have no bearing on Internet freedom or security there or anywhere else.......Repealing “net neutrality” in the US will have no bearing on Internet freedom or security there or anywhere else....

  11. Load Calculations of Radiant Cooling Systems for Sizing the Plant

    OpenAIRE

    Bourdakis, Eleftherios; Kazanci, Ongun B.; Olesen, Bjarne W.

    2015-01-01

    The aim of this study was, by using a building simulation software, to prove that a radiant cooling system should not be sized based on the maximum cooling load but at a lower value. For that reason six radiant cooling models were simulated with two control principles using 100%, 70% and 50% of the maximum cooling load. It was concluded that all tested systems were able to provide an acceptable thermal environment even when the 50% of the maximum cooling load was used. From all the simulated ...

  12. The calculation of the mean radiant temperature of a subject exposed to the solar radiation - a generalised algorithm

    Energy Technology Data Exchange (ETDEWEB)

    La Gennusa, M.; Rizzo, G.; Scaccianoce, G. [Universita dglie Studi di Palermo (Italy). Dpto. di Ricerche Energetiche ed Ambientali; Nucara, A. [Universita Mediterranea di Reggio Calabria (Italy). Dpto. di Informatica

    2005-03-01

    The thermal sensation experienced by a subject in a confined environment is significantly affected by the radiative heat exchange between the human body and the surrounding surfaces: it contributes as far as 30% of the whole thermal exchanges of the subject. Besides, the presence of high-intensity radiation sources like, for example, the sun, may appreciably modify the radiant field to which people are exposed. As a consequence, this could alter notably the comfort conditions. In order of properly taking into account this issue, a simple analytical method is introduced in this work, which allows the easy evaluation of the thermal radiant field induced by the presence of the solar radiation. An application to a typical thermal comfort computation is finally presented. (author)

  13. EFFECT OF THE SCREENS RADIANT REFLECTANCE ON THERMAL TRANSPORT PROCESS IN THE CLADDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    V. D. Sizov

    2016-01-01

    Full Text Available The article analyses variants of the heat insulating layers disposition in relation to the cladding load-carrying structures and demonstrates prime advantages and drawbacks of the three variants. The authors notice that from the heat-engineering viewpoint the variant with exterior side winterization is the most favourable. However, utilizing micromodules as heat-insulating layers screened with leafing aluminum makes it necessary to account for the screens reflecting power. It allows reducing the irradiating component in the combined value of thermal transport through the enclosure and consequently raises the structure thermal resistance or, with parity of these values, leads to lower thickness of the heat-insulating layer. The known data applied for calculating the total heat transmission helps demonstrate reduction of the general heat flux value by 1.4 times, and the heat transmission resistance by 1.76 m2 deg./W. This allows reducing thickness of the heat-insulating layer (with regard of two screens by 0.07 m. Computations illustrate the fact that account for the radiant reflectance of screening enables lowering the rated heat flux passing through the enclosure. Which again allows decreasing the structure thermal resistance and its general thickness (by 70 mm at the expense of small thickness of the heat insulation of micromodules. The humidity regime calculations establish good acceptability of the enclosure service conditions in winter. The period will see no real water vapour condensation. The plotted diagrams of the cladding heat-and-humidity conditions demonstrate that condensation zones do not affect the layer of thermal insulation (micromodules. And the condensation zone with reduction of the heat-insulating layer appears only during ‘severe’ outside temperature conditions of a cold month. Reduced to 230 mm thickness of the wall construction allows utilizing ‘old’ stock of forms with prefabricated panels in parallel with energy

  14. The radiant ephemerides of kappa-Cygnids from the IMO video database

    Science.gov (United States)

    Triglav-Cekada, Mihaela

    2006-08-01

    The analysis of single-station IMO video network data of the July and August period with 36 576 meteors in search of kappa-Cygnid, alpha-Lyrid and zeta-Draconid meteor showers was made using the program Radiant. These showers will be named kappa-Cygnid meteor complex radiants. The detailed analysis of the whole August period from 1993-2004 included the behavior of radiants in different magnitude ranges and different years from 2000 on. Detailed radiant calculations for different velocities for 5g and 10g solar longitude intervals were also done. In 10g solar longitude intervals also the calculations for different magnitude ranges were conducted. The activity of the kappa-Cygnid radiant and the alpha-Lyrid radiant was proven, unlike the zeta-Draconid radiant, where no activity could be confirmed. For the whole August period also the behavior of radiants in separate years 2000-2004, when day-to-day meteor coverage is available, was made. From that it can be hinted on alternating bigger activity of the kappa-Cygnid and alpha-Lyrid radiants. In the years 2000 and 2001 the alpha-Lyrid radiant is more active, when on the contrary in 2002, 2003 and 2004 the kappa-Cygnid radiant is more active. The year 2003 is interesting from another aspect, as three radiants can be seen. If the third radiant is the zeta-Draconid radiant, a few years more video observations will have to be gathered and the radiant calculations repeated. For the day of the kappa-Cygnid meteor complex maximum, on August 18, the mean radiant positions were deduced: the more active kappa-Cygnid radiant lies at alpha=280 deg and delta=+58 deg with an area of the maximum probability of 10 deg x 15 deg, and the less active alpha-Lyrid radiant is placed at alpha=292 deg and delta=+52 deg with a radius of maximum probability of 2 deg. The radiant drift was not possible to obtain as in the 5 deg and 10 deg solar longitude interval calculations the positions of both radiants apparently oscillate. As no change can

  15. Low temperature heating and high temperature cooling embedded water based surface heating and cooling systems

    CERN Document Server

    Babiak, Jan; Petras, Dusan

    2009-01-01

    This Guidebook describes the systems that use water as heat-carrier and when the heat exchange within the conditioned space is more than 50% radiant. Embedded systems insulated from the main building structure (floor, wall and ceiling) are used in all types of buildings and work with heat carriers at low temperatures for heating and relatively high temperature for cooling.

  16. Investigation of the impact of using thermal mass with the net zero energy town house in Toronto using TRNSYS

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, O.; Fung, A.; Tse, H.; Zhang, D. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Mechanical and Industrial Engineering

    2008-07-01

    Since buildings in Canada account for 30 per cent of the country's total energy consumption, it has become necessary to find ways to reduce the overall energy use in buildings. Heating and cooling loads in buildings can be effectively reduced by using the thermal mass incorporated into the building envelope, particularly in climates where a large daily temperature fluctuations exist. Thermal mass is defined as any building material that has a high heat storage capacity that can be integrated into the structural fabric of the building to use the passive solar energy for heating or cooling purposes. Concrete slabs, bricks and ceramic blocks are some of the commonly used materials. This study analyzed the impact of using thermal mass with a highly insulated building envelope such as that used in Low Energy or Net Zero housing. In particular, TRNSYS was used to simulate a Net Zero Energy Town House located in Toronto, in which a ground source heat pump was integrated with an infloor radiant heating system. The simulation revealed that for colder climates such as in Canada, thermal mass can replace some of the insulation while still providing excellent results in terms of the reductions in daily indoor temperature fluctuations. The impact of thermal mass during the winter was more significant when compared with summer, possibly because of the unique construction and orientation of the Net Zero Energy House. The optimum thickness of the concrete slab was determined to be 6 inches for the winter season and 4 inches for summer. The optimum location for the thermal mass was found to be right next to the gypsum wallboard that forms the interior part of the wall. 12 refs., 1 tab., 11 figs.

  17. Thermodynamics and heat transfer in fire fighting

    Science.gov (United States)

    Romanenko, P. N.; Koshmarov, Y. A.; Bashkirtsev, M. P.

    1985-05-01

    The book presents the fundamental principles of thermodynamics and heat transfer with particular reference to their application in problems related to fire prevention. Special attention is given to the study of unsteady heat transfer, radiant heat transfer (including radiation from flames to the surrounding), thermodynamic analysis of the growth of fires and theoretical modeling of fires in building.

  18. Analog to digital converter for two-dimensional radiant energy array computers

    Science.gov (United States)

    Shaefer, D. H.; Strong, J. P., III (Inventor)

    1977-01-01

    The analog to digital converter stage derives a bit array of digital radiant energy signals representative of the amplitudes of an input radiant energy analog signal array and derives an output radiant energy analog signal array to serve as an input to succeeding stages. The converter stage includes a digital radiant energy array device which contains radiant energy array positions so that the analog array is less than a predetermined threshold level. A scaling device amplifies the radiant signal levels of the input array and the digital array so that the radiant energy signal level carried by the digital array corresponds to the threshold level. An adder device adds the signals of the scaled input and digital arrays at corresponding array positions to form the output analog array.

  19. RESTful NET

    CERN Document Server

    Flanders, Jon

    2008-01-01

    RESTful .NET is the first book that teaches Windows developers to build RESTful web services using the latest Microsoft tools. Written by Windows Communication Foundation (WFC) expert Jon Flanders, this hands-on tutorial demonstrates how you can use WCF and other components of the .NET 3.5 Framework to build, deploy and use REST-based web services in a variety of application scenarios. RESTful architecture offers a simpler approach to building web services than SOAP, SOA, and the cumbersome WS- stack. And WCF has proven to be a flexible technology for building distributed systems not necessa

  20. Self-tracking radiant energy collector

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, R.E.

    1978-05-30

    A solar energy conversion device is provided with simplified means for tracking a source of solar energy. In the preferred embodiment, the tracking means is a predeterminedly shaped, heat expandable device operatively connected to an energy concentrator. The energy concentrator is movably mounted and is adapted to direct concentrated energy either towards a suitable energy conversion means in those positions in which the concentration is aligned with respect to the solar energy source, or towards the expandable device in those positions in which the concentrator is disaligned with respect to the solar energy source. Application of concentrated solar energy to the expandable device causes its expansion, which expansion is utilized to move the concentrator into alignment with the energy source. At alignment, concentrated energy is directed from the expandable device toward the energy conversion means.

  1. New Approach to Microclimate Parameter Selection for the Production Area with Heat Supply Systems Based on Gas Infrared Radiators

    Directory of Open Access Journals (Sweden)

    Kurilenko N. I.

    2016-01-01

    Full Text Available There presented experimental research results for the heat transfer behavior in the areas with the radiant heating systems based on the gas infrared radiators. The model of heat-gravitational convection is formulated, that conforms to the transformation conditions of radiant energy coming from the radiators. A new approach to the parameter selection of the indoor climate with the radiant heating systems is developed based on the analysis and collation of experimental data for the temperature patterns and that of the heat flows of the object of research.

  2. Methods of increasing net work output of organic Rankine cycles for low-grade waste heat recovery with a detailed analysis using a zeotropic working fluid mixture and scroll expander

    Science.gov (United States)

    Woodland, Brandon Jay

    An organic Rankine cycle (ORC) is a thermodynamic cycle that is well-suited for waste heat recovery. It is generally employed for waste heat with temperatures in the range of 80 °C -- 300 °C. When the application is strictly to convert waste heat into work, thermal efficiency is not recommended as a key performance metric. In such an application, maximization of the net power output should be the objective rather than maximization of the thermal efficiency. Two alternative cycle configurations that can increase the net power produced from a heat source with a given temperature and flow rate are proposed and analyzed. These cycle configurations are 1) an ORC with two-phase flash expansion and 2) an ORC with a zeotropic working fluid mixture (ZRC). A design-stage ORC model is presented for consistent comparison of multiple ORC configurations. The finite capacity of the heat source and heat sink fluids is a key consideration in this model. Of all working fluids studied for the baseline ORC, R134a and R245fa yield the highest net power output from a given heat source. Results of the design-stage model indicate that the ORC with two-phase flash expansion offers the most improvement over the baseline ORC. However, the level of improvement that could be achieved in practice is highly uncertain due to the requirement of highly efficient two-phase expansion. The ZRC shows improvement over the baseline as long as the condenser fan power requirement is not negligible. At the highest estimated condenser fan power, the ZRC shows the most improvement, while the ORC with flash expansion is no longer beneficial. The ZRC was selected for detailed study because it does not require two-phase expansion. An experimental test rig was used to evaluate baseline ORC performance with R134a and with R245fa. The ZRC was tested on the same rig with a mixture of 62.5% R134a and 37.5% R245fa. The tested expander is a minimally-modified, of-the-shelf automotive scroll compressor. The high

  3. Petri Nets

    Indian Academy of Sciences (India)

    Associate Professor of. Computer Science and. Automation at the Indian. Institute of Science,. Bangalore. His research interests are broadly in the areas of stochastic modeling and scheduling methodologies for future factories; and object oriented modeling. GENERAL I ARTICLE. Petri Nets. 1. Overview and Foundations.

  4. Petri Nets

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 8. Petri Nets - Overview and Foundations. Y Narahari. General Article Volume 4 Issue 8 August 1999 pp ... Author Affiliations. Y Narahari1. Department ot Computer Science and Automation, Indian Institute of Science, Bangalore 560 012, India.

  5. Load calculations of radiant cooling systems for sizing the plant

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    % of the maximum cooling load. It was concluded that all tested systems were able to provide an acceptable thermal environment even when the 50% of the maximum cooling load was used. From all the simulated systems the one that performed the best under both control principles was the ESCS ceiling system. Finally......The aim of this study was, by using a building simulation software, to prove that a radiant cooling system should not be sized based on the maximum cooling load but at a lower value. For that reason six radiant cooling models were simulated with two control principles using 100%, 70% and 50...... it was proved that ventilation systems should be sized based on the maximum cooling load....

  6. Heat

    CERN Document Server

    Lawrence, Ellen

    2016-01-01

    Is it possible to make heat by rubbing your hands together? Why does an ice cube melt when you hold it? In this title, students will conduct experiments to help them understand what heat is. Kids will also investigate concepts such as which materials are good at conducting heat and which are the best insulators. Using everyday items that can easily be found around the house, students will transform into scientists as they carry out step-by-step experiments to answer interesting questions. Along the way, children will pick up important scientific skills. Heat includes seven experiments with detailed, age-appropriate instructions, surprising facts and background information, a "conclusions" section to pull all the concepts in the book together, and a glossary of science words. Colorful, dynamic designs and images truly put the FUN into FUN-damental Experiments.

  7. Development of Personalized Radiant Cooling System for an Office Room

    Energy Technology Data Exchange (ETDEWEB)

    Khare, Vaibhav [Malaviya National Institute of Technology (MNIT), Jaipur, India; Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    The building industry nowadays is facing two major challenges increased concern for energy reduction and growing need for thermal comfort. These challenges have led many researchers to develop Radiant Cooling Systems that show a large potential for energy savings. This study aims to develop a personalized cooling system using the principle of radiant cooling integrated with conventional all-air system to achieve better thermal environment at the workspace. Personalized conditioning aims to create a microclimatic zone around a single workspace. In this way, the energy is deployed only where it is actually needed, and the individual s needs for thermal comfort are fulfilled. To study the effect of air temperature along with air temperature distribution for workspace, air temperature near the vicinity of the occupant has been obtained as a result of Computational Fluid Dynamics (CFD) simulation using FLUENT. The analysis showed that personalized radiant system improves thermal environment near the workspace and allows all-air systems to work at higher thermostat temperature without compromising the thermal comfort, which in turn reduces its energy consumption.

  8. Temperature patterns in the gas infrared radiator heating area

    Directory of Open Access Journals (Sweden)

    Kurilenko N.I.

    2015-01-01

    Full Text Available The obtained results of experimental studies provide the basis for the heat transfer mechanism specification on the studied conditions that are typical for many practical applications. It was proved appropriateness of the natural convection and heat conduction process simulation while analyzing the heat transfer in rectangular enclosures with the radiant heating sources at the high bound.

  9. Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump

    OpenAIRE

    Bell, Ian; Braun, James

    2012-01-01

    In residential heat pump systems, the motivation for secondary loop systems is to allow for the use of flammable or toxic refrigerants with lower global warming potentials than the currently employed HFC refrigerants. The addition of radiant panels as integral building components (embedded in concrete at construction or attached to the underside of wood flooring) is becoming more common. Combining the large surface area of the radiant panel and an efficient primary loop, a hydronic secondary ...

  10. Design and evaluation of net radiometers

    Science.gov (United States)

    Fritschen, Leo J.; Fritschen, Charles L.

    Net radiometer designs were evaluated with respect to long and short wave sensitivities and to the effect of ambient wind on the signal. The design features of the instrument with the best overall performance include: equal sensitivity to long and short wave radiation, a thermal pile which is thermally isolated from the frame, a white guard ring, pathways for internal circulation between the top and bottom hemispheres, and self-supporting windshields. The windshields have O-ring seals, a ball joint is provided for ease of leveling, and ample desiccant is enclosed in the mounting pipe. Under a high radiant load, the net radiometer signal decreased by 2.5, 3.7, and 4.3 percent at wind speeds of 12.5, 4.6, and 7.5 m/s.

  11. Radiant flash pyrolysis of biomass using a xenon flashtube

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, M.W.; Antal, M.J. Jr.

    1984-06-01

    Biomass materials, including lignin, redwood, corn cob, Calotropis Procera, Leucaena wood, Kraft paper, newsprint, cow manure, D-glucose, and D-cellobiose, were pyrolyzed in vacuum by the visible radiant flux emitted from a Xenon flashtube. The flux density exceeded 8 kW/cm/sup 2/ during the 1 ms flash. Sirup yields were low (avg 25%), while the gas yield was high (avg 32%). The gaseous products were composed primarily of CO and CO/sub 2/. The high relative yields of CO establish the existence of a high temperature fragmentation pathway active during the flash pyrolysis of all biomass materials. 39 references, 2 figures, 5 tables.

  12. Radiant science, dark politics: a memoir of the nuclear age

    Energy Technology Data Exchange (ETDEWEB)

    Kamen, M.D.

    1985-01-01

    The reviewer describes Radiant Science, Dark Politics: A Memoir of the Nuclear Age in contrast to a memoir by James R. Killian, Jr., a contemporary of Kamen. Kamen, co-discoverer of carbon-14 and a valued member of the Berkeley Radiation Laboratory, was fired in 1944 and blackballed as a security risk. Rehabilitated by the end of the war, his continued fight against political injustice through the McCarthy era colors the book and, for the reviewer, makes it self-serving. Kamen's later scientific work reflected his desire to work alone rather than in collaboration.

  13. Radiant Energy Power Source for Jet Aircraft. Final performance report

    Energy Technology Data Exchange (ETDEWEB)

    Doellner, O.L.

    1992-02-01

    This report beings with a historical overview on the origin and early beginnings of Radiant Energy Power Source for Jet Aircraft. The report reviews the work done in Phase I (Grant DE-FG01-82CE-15144) and then gives a discussion of Phase II (Grant DE-FG01-86CE-15301). Included is a reasonably detailed discussion of photovoltaic cells and the research and development needed in this area. The report closes with a historical perspective and summary related to situations historically encountered on projects of this nature. 15 refs.

  14. Luz Pozo Garza: Memoria radiante de una mujer solar

    OpenAIRE

    Blanco, Carmen

    2006-01-01

    The poetry of Luz Poz Garza is a Platonic flashing beauty cosmos ruled by clarity, depth and harmony symbolized in the name that gave birth to it: that of a “solar woman”, fully self-assured in her life and in her work, gathered in the “heart of light” of her poetry. Memoria solar, the title of her complete poetry work, contains the radiant memory of the solar woman, a curved by plenitude cosmos that shelters a first microcosmos (that of her youth poetry), red fruit such as orange o meat appl...

  15. Simplified heat transfer analysis for windows with venetian blinds: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Lomanowski, B.A.; Wright, J.L. [Waterloo Univ., ON (Canada). Dept. of Mechanical Engineering

    2007-07-01

    A heat transfer analysis of a window with a light- and dark-coloured venetian blind in 3 different glazing and shading configurations was presented. The contributions of total solar transmission, longwave radiant gain and convective gain to net heat gain were investigated. The glazing/shading system consisted of 2 glazing layers and 1 venetian blind layer. The Yahoda and Wright method was used to calculate the effective longwave radiative properties of the blind. Absorbed quantities of solar radiation in each layer were calculated with a simplified solar optical model. A 1-D center-glass multi-layer heat transfer analysis was then performed. Various convection models were used to characterize each blind configuration. An empirical correlation for free convection on a vertical surface was used to obtain the average Nusselt number of the inside glazing layer. Convection on the outdoor glazing and blind was modelled using a forced convection correlation. Results from the simplified solar-optical model were then combined with the heat transfer analysis. Meteorological data were used to consider the configurations in both winter and summer conditions. Hourly results for the between the panes blind configuration showed a significant reduction in net heat gain. The outdoor blind configurations showed a dramatic reduction in net heat gain. Solar transmission was higher with the light-coloured blind. The optimum blind position in the terms of energy savings was the outdoor side blind. It was concluded that the ability to quantify the contribution of separate heat gain components offers significant insight into the thermal characteristics of complex glazing and shading systems. 17 refs., 1 tab., 10 figs.

  16. A Mini-channel Heat Exchanger System for Heating, Boiling, and Superheating Water by Radiant Combustion

    National Research Council Canada - National Science Library

    Sawyer, Mikel

    2004-01-01

    .... The channel hydraulic diameter was 0.14 Cm. The Reynolds number for the water ranged from 620 to 1,260 in the boiling section and from 1,260 to 3,140 in the superheating section, based on averaged fluid...

  17. Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

    Science.gov (United States)

    Olson, Sandra

    2011-01-01

    To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

  18. Dynamic ignition regime of condensed system by radiate heat flux

    Science.gov (United States)

    Arkhipov, V. A.; Zolotorev, N. N.; Korotkikh, A. G.; Kuznetsov, V. T.

    2017-05-01

    The main ignition characteristics of high-energy materials are the ignition time and critical heat flux allowing evaluation of the critical conditions for ignition, fire and explosive safety for the test solid propellants. The ignition process is typically studied in stationary conditions of heat input at constant temperature of the heating surface, environment or the radiate heat flux on the sample surface. In real conditions, ignition is usually effected at variable time-dependent values of the heat flux. In this case, the heated layer is formed on the sample surface in dynamic conditions and significantly depends on the heat flux change, i.e. increasing or decreasing falling heat flux in the reaction period of the propellant sample. This paper presents a method for measuring the ignition characteristics of a high-energy material sample in initiation of the dynamic radiant heat flux, which includes the measurement of the ignition time when exposed to a sample time varying radiant heat flux given intensity. In case of pyroxyline containing 1 wt. % of soot, it is shown that the ignition times are reduced by 20-50 % depending on the initial value of the radiant flux density in initiation by increasing or decreasing radiant heat flux compared with the stationary conditions of heat supply in the same ambient conditions.

  19. Thermal Conditions in a Simulated Office Environment with Convective and Radiant Cooling Systems

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Kostov, Kalin

    2013-01-01

    The thermal conditions in a two person office room were measured with four air conditioning systems: chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and four desk partition mounted local radiant cooling panels with mixing...

  20. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  1. Radiant patio heaters for use in private households and restaurants; Terrassenstrahler fuer die private und gastronomische Nutzung

    Energy Technology Data Exchange (ETDEWEB)

    Kaempf, A. [GoGaS Goch GmbH und Co., Dortmund (Germany)

    2003-02-01

    Open-air venues are popular not only in the Mediterranean region; beergardens, outdoor patios and street cafes are also becoming increasingly popular meeting places in northern Europe, too. Due to the prevailing climate, however, this unfortunately remains a pleasure restricted to only a few weeks of the year. Convenient and efficient heating of such outdoor areas is not possible using conventional heating systems. Radiant patio heaters, which provide a pleasant climate throughout the year, are now available for this purpose, however. (orig.) [German] Treffpunkte unter freiem Himmel sind nicht nur in der Mittelmeerregion beliebt, auch in Deutschland finden Biergaerten, Aussenterrassen bzw. Strassencafes immer staerkeren Zuspruch fuer gesellschaftliche Begegnungen. Aufgrund der hiesigen klimatischen Bedingungen ist dieses Vergnuegen leider nur auf wenige Wochen im Jahr beschraenkt. Eine komfortable und effiziente Temperierung dieser Flaechen ist mit konventionellen Heizungssystemen im Aussenbereich nicht moeglich. Hierfuer bieten sich Terrassenstrahler an, die ganzjaehrig fuer ein angenehmens Klima sorgen. (orig.)

  2. Performance evaluation of radiant cooling system application on a university building in Indonesia

    Science.gov (United States)

    Satrio, Pujo; Sholahudin, S.; Nasruddin

    2017-03-01

    The paper describes a study developed to estimate the energy savings potential of a radiant cooling system installed in an institutional building in Indonesia. The simulations were carried out using IESVE to evaluate thermal performance and energy consumption The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption and temperature distribution to determine the proportional energy savings and occupant comfort under different systems. The result was radiant cooling which integrated with a Dedicated Outside Air System (DOAS) could make 41,84% energy savings compared to the installed cooling system. The Computational Fluid Dynamics (CFD) simulation showed that a radiant system integrated with DOAS provides superior human comfort than a radiant system integrated with Variable Air Volume (VAV). Percentage People Dissatisfied was kept below 10% using the proposed system.

  3. The effect of urban geometry on mean radiant temperature under future climate change: a study of three European cities.

    Science.gov (United States)

    Lau, Kevin Ka-Lun; Lindberg, Fredrik; Rayner, David; Thorsson, Sofia

    2015-07-01

    Future anthropogenic climate change is likely to increase the air temperature (T(a)) across Europe and increase the frequency, duration and magnitude of severe heat stress events. Heat stress events are generally associated with clear-sky conditions and high T(a), which give rise to high radiant heat load, i.e. mean radiant temperature (T(mrt)). In urban environments, T mrt is strongly influenced by urban geometry. The present study examines the effect of urban geometry on daytime heat stress in three European cities (Gothenburg in Sweden, Frankfurt in Germany and Porto in Portugal) under present and future climates, using T(mrt) as an indicator of heat stress. It is found that severe heat stress occurs in all three cities. Similar maximum daytime T(mrt) is found in open areas in all three cities despite of the latitudinal differences in average daytime T(mrt). In contrast, dense urban structures like narrow street canyons are able to mitigate heat stress in the summer, without causing substantial changes in T(mrt) in the winter. Although the T(mrt) averages are similar for the north-south and east-west street canyons in each city, the number of hours when T(mrt) exceeds the threshold values of 55.5 and 59.4 °C-used as indicators of moderate and severe heat stress-in the north-south canyons is much higher than that in the east-west canyons. Using statistically downscaled data from a regional climate model, it is found that the study sites were generally warmer in the future scenario, especially Porto, which would further exacerbate heat stress in urban areas. However, a decrease in solar radiation in Gothenburg and Frankfurt reduces T(mrt) in the spring, while the reduction in T(mrt) is somewhat offset by increasing T(a) in other seasons. It suggests that changes in the T(mrt) under the future scenario are dominated by variations in T(a). Nonetheless, the intra-urban differences remain relatively stable in the future. These findings suggest that dense urban

  4. Heat gain from thermal radiation through protective clothing with different insulation, reflectivity and vapour permeability

    NARCIS (Netherlands)

    Bröde, P.; Kuklane, K.; Candas, V.; Hartog, E.A. den; Griefahn, B.; Holmér, I.; Meinander, H.; Nocker, W.; Richards, M.; Havenith, G.

    2010-01-01

    The heat transferred through protective clothing under long wave radiation compared to a reference condition without radiant stress was determined in thermal manikin experiments. The influence of clothing insulation and reflectivity, and the interaction with wind and wet underclothing were

  5. TELBE - the super-radiant THz facility at ELBE

    Energy Technology Data Exchange (ETDEWEB)

    Green, Bertram; Kovalev, Sergei; Hauser, Jens; Kuntzsch, Michael; Schneider, Harald; Winnerl, Stephan; Seidel, Wolfgang; Zvyagin, Sergei; Lehnert, Ulf; Helm, Manfred; Michel, Peter; Gensch, Michael [Helmholtz-Zentrum Dresden-Rossendorf (Germany); Al-Shemmary, Alaa; Radu, Ilie; Stojanovic, Nikola; Cavalleri, Andrea [Deutsches Elektronen-Synchrotron (Germany); Wall, Simon [FHI Berlin (Germany); Eng, Lukas M. [Technische Universitaet Dresden (Germany); Heberle, Joachim [FU Berlin (Germany)

    2013-07-01

    It has been shown recently that relativistic electron bunches can be utilized for the generation of super-radiant coherent THz radiation by one single pass through an undulator, bending magnet, or CDR/CTR screens. However, the high THz fields have all been achieved at large accelerators that allow for high electron beam energies. A crucially important research topic for the next years at the HZDR is therefore to investigate whether an equally fine control over highly charged electron bunch form can be routinely achieved in a low electron beam energy accelerator like ELBE. If successful this development would allow the generation of high field THz fields by linear accelerators at considerably reduced cost. Given stable operation can be provided, TELBE, could also become a world-wide unique research facility for high field THz science. The current status and an outlook on future developments are presented.

  6. Luz Pozo Garza: Memoria radiante de una mujer solar

    Directory of Open Access Journals (Sweden)

    Blanco, Carmen

    2006-08-01

    Full Text Available The poetry of Luz Poz Garza is a Platonic flashing beauty cosmos ruled by clarity, depth and harmony symbolized in the name that gave birth to it: that of a “solar woman”, fully self-assured in her life and in her work, gathered in the “heart of light” of her poetry. Memoria solar, the title of her complete poetry work, contains the radiant memory of the solar woman, a curved by plenitude cosmos that shelters a first microcosmos (that of her youth poetry, red fruit such as orange o meat apple, and a second microcosmos (that of her maturity poetry of white or blue flower of total mystic lucidity, such as solar camellia, rose o lotus.La poesía de Luz Pozo Garza es un cosmos fulgurante de belleza platónica regida por la claridad, la profundidad y la armonía simbolizadas en el nombre que lo dio a luz, el de una “mujer solar” plenamente autoafirmada en su vida y en su obra, unidas en el “corazón de Luz” de su poesía. Memoria solar, el título de su obra poética completa contiene su memoria radiante de mujer solar, un cosmos curvo de plenitud que guarda un microcosmos primero, el de su poesía de juventud, de fruto rojo, cual naranja o manzana de la carne, y un microcosmos segundo, el de su poesía de madurez, de flor blanca o azul de la total lucidez mística, cual camelia, rosa o loto solares.

  7. Absolute detector-based spectrally tunable radiant source using digital micromirror device and supercontinuum fiber laser.

    Science.gov (United States)

    Li, Zhigang; Wang, Xiaoxu; Zheng, Yuquan; Li, Futian

    2017-06-10

    High-accuracy absolute detector-based spectroradiometric calibration techniques traceable to cryogenic absolute radiometers have made progress rapidly in recent decades under the impetus of atmospheric quantitative spectral remote sensing. A high brightness spectrally tunable radiant source using a supercontinuum fiber laser and a digital micromirror device (DMD) has been developed to meet demands of spectroradiometric calibrations for ground-based, aeronautics-based, and aerospace-based remote sensing instruments and spectral simulations of natural scenes such as the sun and atmosphere. Using a supercontinuum fiber laser as a radiant source, the spectral radiance of the spectrally tunable radiant source is 20 times higher than the spectrally tunable radiant source using conventional radiant sources such as tungsten halogen lamps, xenon lamps, or LED lamps, and the stability is better than ±0.3%/h. Using a DMD, the spectrally tunable radiant source possesses two working modes. In narrow-band modes, it is calibrated by an absolute detector, and in broad-band modes, it can calibrate for remote sensing instrument. The uncertainty of the spectral radiance of the spectrally tunable radiant source is estimated at less than 1.87% at 350 nm to 0.85% at 750 nm, and compared to only standard lamp-based calibration, a greater improvement is gained.

  8. Perceived air quality, thermal comfort, and SBS symptoms at low air temperature and increased radiant temperature

    DEFF Research Database (Denmark)

    Toftum, Jørn; Reimann, Gregers Peter; Foldbjerg, P.

    2002-01-01

    This study investigated if low air temperature, which is known to improve the perception of air quality, also can reduce the intensity of some SBS symptoms. In a low-polluting office, human subjects were exposed to air at two temperatures 23 deg.C and 18 deg.C both with and without a pollution so.......C suggested an improvement of the perceived air quality, while no systematic effect on symptom intensity was observed. The overall indoor environment was evaluated equally acceptable at both temperatures due to local thermal discomfort at the low air temperature.......This study investigated if low air temperature, which is known to improve the perception of air quality, also can reduce the intensity of some SBS symptoms. In a low-polluting office, human subjects were exposed to air at two temperatures 23 deg.C and 18 deg.C both with and without a pollution...... source present at the low temperature. To maintain overall thermal neutrality, the low air temperature was partly compensated for by individually controlled radiant heating, and partly by allowing subjects to modify clothing insulation. A reduction of the air temperature from 23 deg.C to 18 deg...

  9. Heat stress of two tropical seagrass species during low tides - impact on underwater net photosynthesis, dark respiration and diel in situ internal aeration.

    Science.gov (United States)

    Pedersen, Ole; Colmer, Timothy D; Borum, Jens; Zavala-Perez, Andrea; Kendrick, Gary A

    2016-06-01

    Seagrasses grow submerged in aerated seawater but often in low O2 sediments. Elevated temperatures and low O2 are stress factors. Internal aeration was measured in two tropical seagrasses, Thalassia hemprichii and Enhalus acoroides, growing with extreme tides and diel temperature amplitudes. Temperature effects on net photosynthesis (PN ) and dark respiration (RD ) of leaves were evaluated. Daytime low tide was characterized by high pO2 (54 kPa), pH (8.8) and temperature (38°C) in shallow pools. As PN was maximum at 33°C (9.1 and 7.2 μmol O2  m(-2) s(-1) in T. hemprichii and E. acoroides, respectively), the high temperatures and reduced CO2 would have diminished PN , whereas RD increased (Q10 of 2.0-2.7) above that at 33°C (0.45 and 0.33 μmol O2  m(-2)  s(-1) , respectively). During night-time low tides, O2 declined resulting in shoot base anoxia in both species, but incoming water containing c. 20 kPa O2 relieved the anoxia. Shoots exposed to 40°C for 4 h showed recovery of PN and RD , whereas 45°C resulted in leaf damage. These seagrasses are 'living near the edge', tolerant of current diel O2 and temperature extremes, but if temperatures rise both species may be threatened in this habitat. © 2016 The Authors. New Phytologist © 2016 New Phytologist Trust.

  10. Heating systems for the lying zones of piglets. Heizungssysteme im Ferkelliegebereich

    Energy Technology Data Exchange (ETDEWEB)

    Jungbluth, T.; Sommer, M. (Hohenheim Univ., Stuttgart (Germany, F.R.))

    1986-01-01

    The authors studied weak points of heatings for the lying zones of piglets. Both inadequate heat supply and excessive heat cause piglets to leave the area where they are supposed to stay. After discussing gas radiant heaters of low capacity, hints are given on possibilities for automatic control of electric infrared radiant heaters. Apart from the performances and temperature distributions of the different heatings, hot water as an energy source is also dealt with. A survey of costs for comparing the different heating systems is appended. (orig.).

  11. An experimental study of thermal comfort at different combinations of air and mean radiant temperature

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.

    2009-01-01

    It is often discussed if a person prefers a low air temperature (ta) and a high mean radiant temperature (tr), vice-versa or it does not matter as long as the operative temperature is acceptable. One of the hypotheses is that it does not matter for thermal comfort but for perceived air quality......, a lower air temperature is preferred. This paper presents an experimental study with 30 human subjects exposed to three different combinations of air- and mean radiant temperature with an operative temperature around 23 °C. The subjects gave subjective evaluations of thermal comfort and perceived air...... quality during the experiments. The PMV-index gave a good estimation of thermal sensation vote (TSV) when the air and mean radiant temperature were the same. In the environment with different air- and mean radiant temperatures, a thermal comfort evaluation shows an error up to 1 scale unit on the 7-point...

  12. Cooling load calculations of radiant and all-air systems for commercial buildings

    OpenAIRE

    Bourdakis, Eleftherios; Bauman, Fred; Schiavon, Stefano; Raftery, Paul; Olesen, Bjarne W.

    2017-01-01

    The authors simulated in TRNSYS three radiant systems coupled with a 50% sized variable air volume (VAV) system and a 50% sized all-air VAV system with night ventilation. The objective of this study was to identify the differences in the cooling load profiles of the examined systems when they are sized based on different levels of the maximum cooling demand. The authors concluded that for high thermal mass radiant system nocturnal operation was adequate for providing an acceptable thermal env...

  13. Radiant cooling in US office buildings: Towards eliminating the perception of climate-imposed barriers

    Energy Technology Data Exchange (ETDEWEB)

    Stetiu, Corina [Univ. of California, Berkeley, CA (United States)

    1998-01-01

    Much attention is being given to improving the efficiency of air-conditioning systems through the promotion of more efficient cooling technologies. One such alternative, radiant cooling, is the subject of this thesis. Performance information from Western European buildings equipped with radiant cooling systems indicates that these systems not only reduce the building energy consumption but also provide additional economic and comfort-related benefits. Their potential in other markets such as the US has been largely overlooked due to lack of practical demonstration, and to the absence of simulation tools capable of predicting system performance in different climates. This thesis describes the development of RADCOOL, a simulation tool that models thermal and moisture-related effects in spaces equipped with radiant cooling systems. The thesis then conducts the first in-depth investigation of the climate-related aspects of the performance of radiant cooling systems in office buildings. The results of the investigation show that a building equipped with a radiant cooling system can be operated in any US climate with small risk of condensation. For the office space examined in the thesis, employing a radiant cooling system instead of a traditional all-air system can save on average 30% of the energy consumption and 27% of the peak power demand due to space conditioning. The savings potential is climate-dependent, and is larger in retrofitted buildings than in new construction. This thesis demonstrates the high performance potential of radiant cooling systems across a broad range of US climates. It further discusses the economics governing the US air-conditioning market and identifies the type of policy interventions and other measures that could encourage the adoption of radiant cooling in this market.

  14. Cooling load calculations of radiant and all-air systems for commercial buildings

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Bauman, Fred; Schiavon, Stefano

    The authors simulated in TRNSYS three radiant systems coupled with a 50% sized variable air volume (VAV) system and a 50% sized all-air VAV system with night ventilation. The objective of this study was to identify the differences in the cooling load profiles of the examined systems when they are......The authors simulated in TRNSYS three radiant systems coupled with a 50% sized variable air volume (VAV) system and a 50% sized all-air VAV system with night ventilation. The objective of this study was to identify the differences in the cooling load profiles of the examined systems when...... they are sized based on different levels of the maximum cooling demand. The authors concluded that for high thermal mass radiant system nocturnal operation was adequate for providing an acceptable thermal environment even when the radiant system was sized based on the 50% of the maximum cooling demand. The 50......% all-air system alone was able to provide comfort if night cooling was implemented. On the other hand, radiant cooling panels (low thermal mass) should be operating during the occupancy period. When sizing a high thermal mass radiant cooling system, the effect of thermal inertia and the response time...

  15. Thermal inertia and radiating average Temperature. A brief analysis of some causes of discomfort; Inercia Termica y Temperatura media radiante. Un breve analisis de algunas causas de disconfort

    Energy Technology Data Exchange (ETDEWEB)

    Arroba, M.

    2008-07-01

    Radiant average temperature in walls is as important as dry air temperature to achieve thermal comfort of users of a local. An excessive discrepancy between these levels, or an asymmetric distribution of the surface temperature of fences, may cause localized thermal discomfort, an effect impossible to compensate by rising dry air temperature. Thermal inertia and its concentration must be properly studied in order to handle this parameters, inside or outside the building, on both sides of the cladding or none depending on the weather, the bio climatic strategies used, heating and air conditioning systems and planned use of the building. (Author)

  16. Synthetic gas radiant cooler with internal quenching and purging facilities

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M.C.; Gulko, G.M.

    1993-08-10

    A radiant syngas cooler is described for treating a stream of hot, particulate-containing synthesis gas effluent, which cooler comprises an elongated upright shell, a water bath at the shell lower end, a first dip tube depending from said shell and defining a disengagement zone at the shell lower end above said water bath, a water wall extending internally of said shell forming an internal chamber and being spaced from the inner wall of said shell to define an elongated annulus there between, inlet means in said shell communicated with said internal chamber to conduct said stream of hot particulate containing syngas thereto, a second dip tube depending from said water wall, spaced inwardly of said first dip tube to define a constricted annulus there between which terminates in said water bath, flow control means for communicating said annulus with a pressurized source of a purge gas, whereby said purge gas and said particulate-carrying synthesis gas will enter said bath concurrently, and at least one gas discharge port communicated with said disengagement zone to conduct cooled gas therefrom.

  17. Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Eigler, N.; Whiting, J.; Chernomorsky, A.; Jackson, J.; Knapp, F.F., Jr.; Litvack, F.

    1998-01-16

    RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} over-the-wire, and TNT{trademark} rapid exchange stent delivery balloons. These balloons have thickened polyethylene walls to augment puncture resistance; dual radio-opaque markers and specially configured connectors.

  18. Ignition of wood subjected to the decreasing radiant energy flux

    Science.gov (United States)

    Kuznetsov, V. T.; Filkov, A. I.; Isaev, Yu N.; Guk, V. O.

    2015-04-01

    In this paper we analyze the ignition of wood samples subjected to the decreasing heat flow. The experimental setup was created on the base of the optical wave "Uran-1". The intensity of the heat flow was changed during the experiment by moving the test sample along the optical axis of the elliptic reflector in the setup. Pine wood was used as the test samples. We received the delay times for ignition of pine wood during heating by the decreasing heat flow. The received data were compared with the data for a static heat flow.

  19. [Health risks from infrared emissions from radiant tube heaters in the workplace].

    Science.gov (United States)

    Bergamaschi, A; Grandi, C; D'Addato, M; Di Carlo, V; Russo, A

    1995-01-01

    With the exception of domestic rooms, Overhead Radiant Tube Heaters (ORTH) are an effective system for indoor heating (e.g. warehouses, factories, garage workshops, shipyards, greenhouses, schools hall etc.). The growing number of units installed is due to several advantages, such as uniform heating, absence of air movements, energy saving, versatility and safety. Indoor heating is obtained by an infrared emission, which is produced by the circulation of combustion exhaust gases within tubes and is collected by a set of reflecting surfaces located around the tubes. In the present communication, the attention is driven on the characteristics of ORTH infrared emissions, with reference to potential health risks for the exposed people (especially people working within areas heated by this system). A reason for this is represented by the existence of a specific italian regulation (Circolare N. 1322/4134-28.01.1992, Direzione Generale della Protezione Civile-Ministero dell'Interno). Following the last one, ORTH surface temperatures resulting in a spectral emission which includes wavelengths less than 3 microns have to be considered, in the case of ORTHs with thermal power greater than 34.89 kW, as hazardous for exposed people. Although the ORTHs emission spectrum partially covers the near infrared region (0.8-1.4 microns) at 400 degrees Celsius and may adversely affect the retained tissue a gross evaluation of the near infrared energetic flux, weightened on the surface unit, allows to exclude this risk. On the opposite, the results of the same evaluation carried out in the medium and far infrared spectral region at 200 degrees-400 degrees Celsius (the normal temperature range for ORTHs) do not allow to preliminary exclude a thermal risk for eye structures such as lens, near the tube surface at least. In every case, a burn hazard for both corneal tissue and skin is excluded. With the aim to carry out a detailed set of radiometric estimates, some preliminary considerations

  20. Fundamental principles of heat transfer

    CERN Document Server

    Whitaker, Stephen

    1977-01-01

    Fundamental Principles of Heat Transfer introduces the fundamental concepts of heat transfer: conduction, convection, and radiation. It presents theoretical developments and example and design problems and illustrates the practical applications of fundamental principles. The chapters in this book cover various topics such as one-dimensional and transient heat conduction, energy and turbulent transport, forced convection, thermal radiation, and radiant energy exchange. There are example problems and solutions at the end of every chapter dealing with design problems. This book is a valuable int

  1. SOLWEIG 1.0--modelling spatial variations of 3D radiant fluxes and mean radiant temperature in complex urban settings.

    Science.gov (United States)

    Lindberg, Fredrik; Holmer, Björn; Thorsson, Sofia

    2008-09-01

    The mean radiant temperature, T(mrt), which sums up all shortwave and longwave radiation fluxes (both direct and reflected) to which the human body is exposed is one of the key meteorological parameters governing human energy balance and the thermal comfort of man. In this paper, a new radiation model (SOLWEIG 1.0), which simulates spatial variations of 3D radiation fluxes and T(mrt) in complex urban settings, is presented. The T(mrt) is derived by modelling shortwave and longwave radiation fluxes in six directions (upward, downward and from the four cardinal points) and angular factors. The model requires a limited number of inputs, such as direct, diffuse and global shortwave radiation, air temperature, relative humidity, urban geometry and geographical information (latitude, longitude and elevation). The model was evaluated using 7 days of integral radiation measurements at two sites with different building geometries--a large square and a small courtyard in Göteborg, Sweden (57 degrees N)--across different seasons and in various weather conditions. The evaluation reveals good agreement between modelled and measured values of T(mrt), with an overall good correspondence of R (2) = 0.94, (p < 0.01, RMSE = 4.8 K). SOLWEIG 1.0 is still under development. Future work will incorporate a vegetation scheme, as well as an improvement of the estimation of fluxes from the four cardinal points.

  2. Heat Emission from a Burning Cigarette

    OpenAIRE

    Miura K; Nagao A; Ueyama K

    2014-01-01

    We investigated the relationship between the smoldering burn rate and the heat transfer from a burning cigarette by measuring the heat emitted by radiation and convection, separately. The net heat generated and the net heat emitted by a burning cigarette did not vary with a change of the cigarette smoldering burn rate. The total heat emitted from a statically burning cigarette was about 50% of the total combustion heat. About 50% of the heat emitted was released as radiation heat. The smolder...

  3. NA-NET numerical analysis net

    Energy Technology Data Exchange (ETDEWEB)

    Dongarra, J. [Tennessee Univ., Knoxville, TN (United States). Dept. of Computer Science]|[Oak Ridge National Lab., TN (United States); Rosener, B. [Tennessee Univ., Knoxville, TN (United States). Dept. of Computer Science

    1991-12-01

    This report describes a facility called NA-NET created to allow numerical analysts (na) an easy method of communicating with one another. The main advantage of the NA-NET is uniformity of addressing. All mail is addressed to the Internet host ``na-net.ornl.gov`` at Oak Ridge National Laboratory. Hence, members of the NA-NET do not need to remember complicated addresses or even where a member is currently located. As long as moving members change their e-mail address in the NA-NET everything works smoothly. The NA-NET system is currently located at Oak Ridge National Laboratory. It is running on the same machine that serves netlib. Netlib is a separate facility that distributes mathematical software via electronic mail. For more information on netlib consult, or send the one-line message ``send index`` to netlib{at}ornl.gov. The following report describes the current NA-NET system from both a user`s perspective and from an implementation perspective. Currently, there are over 2100 members in the NA-NET. An average of 110 mail messages pass through this facility daily.

  4. NA-NET numerical analysis net

    Energy Technology Data Exchange (ETDEWEB)

    Dongarra, J. (Tennessee Univ., Knoxville, TN (United States). Dept. of Computer Science Oak Ridge National Lab., TN (United States)); Rosener, B. (Tennessee Univ., Knoxville, TN (United States). Dept. of Computer Science)

    1991-12-01

    This report describes a facility called NA-NET created to allow numerical analysts (na) an easy method of communicating with one another. The main advantage of the NA-NET is uniformity of addressing. All mail is addressed to the Internet host na-net.ornl.gov'' at Oak Ridge National Laboratory. Hence, members of the NA-NET do not need to remember complicated addresses or even where a member is currently located. As long as moving members change their e-mail address in the NA-NET everything works smoothly. The NA-NET system is currently located at Oak Ridge National Laboratory. It is running on the same machine that serves netlib. Netlib is a separate facility that distributes mathematical software via electronic mail. For more information on netlib consult, or send the one-line message send index'' to netlib{at}ornl.gov. The following report describes the current NA-NET system from both a user's perspective and from an implementation perspective. Currently, there are over 2100 members in the NA-NET. An average of 110 mail messages pass through this facility daily.

  5. Blanchability and sensory quality of large runner peanuts blanched in a radiant wall oven using infrared radiation.

    Science.gov (United States)

    Kettler, Katrina; Adhikari, Koushik; Singh, Rakesh K

    2017-10-01

    The main factors behind the growing popularity of infrared radiation heating in food processing include its energy efficiency, food quality retention and process speed, as well as the simplicity of equipment. Infrared radiation was employed as an alternative heat treatment to the conventional hot air method used in peanut blanching. The present study aimed to investigate the application of infrared heating for blanching peanuts and determine their blanchability and sensory quality under various processing conditions. The total blanchabilities (expressed as a percentage of total blanched) of the infrared radiation trials (radiant wall oven) at 343 °C for 1.5 min, 316 °C for 1.5 min, 288 °C for 1.5 min and 343 °C for 1 min did not differ significantly compared to the hot air control trials (impingement oven) at 100 °C for 30 and 20 min. All infrared trials had significantly lower (P infrared samples demonstrated the possible initiation of oxidation for the conventionally blanched sample at 18 weeks of storage at 24 °C (room temperature), with no indication of oxidation in the infrared samples stored at the same temperature. Infrared radiation peanut blanching is a viable alternative to conventional hot air blanching because of the shorter process time and longer shelf-life, as evident from the sensory storage study. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  6. Net Ecosystem Carbon Flux

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Net Ecosystem Carbon Flux is defined as the year-over-year change in Total Ecosystem Carbon Stock, or the net rate of carbon exchange between an ecosystem and the...

  7. Effect of Curing Light Barriers and Light Types on Radiant Exposure and Composite Conversion.

    Science.gov (United States)

    Sword, Rhoda Joyner; Do, Uyen Ngoc; Chang, Jonathan Hu; Rueggeberg, Frederick Allen

    2016-01-01

    Previous research investigated the effects of curing tip barriers on light output and composite properties, but no study has measured the effect of a wide variety of barriers and curing light types on delivered radiant exposure and the resulting composite cure 2 mm below the radiated surface. Six barrier materials and six curing light types were tested. Spectroradiometry was used to measure irradiance with and without barriers for each light type, and radiant exposure values were determined for a commercial camphorquinone-based dental composite material. Composite monomer conversion was measured at 10 minutes following exposure for each light type/barrier condition (N = 5) using infrared spectroscopy. Results were subjected to one-way analyses of variance for radiant exposure and conversion among barrier types within a given curing light: preset alpha 0.05. All barriers significantly reduced radiant exposure compared with the uncovered tip, but the use of the two polywave LEDs covered with a latex-based barrier demonstrated significantly lower conversion values. Although light-curing barriers reduce radiant exposure to a restorative material over a recommended exposure, this reduction is not sufficient to cause significant reduction in composite cure, except when using a latex-based barrier and a polywave LED curing light. Clinicians need to be aware of the possible interaction between curing light barriers and curing light type in order to optimally photocure restorative materials. © 2015 Wiley Periodicals, Inc.

  8. Professional Enterprise NET

    CERN Document Server

    Arking, Jon

    2010-01-01

    Comprehensive coverage to help experienced .NET developers create flexible, extensible enterprise application code If you're an experienced Microsoft .NET developer, you'll find in this book a road map to the latest enterprise development methodologies. It covers the tools you will use in addition to Visual Studio, including Spring.NET and nUnit, and applies to development with ASP.NET, C#, VB, Office (VBA), and database. You will find comprehensive coverage of the tools and practices that professional .NET developers need to master in order to build enterprise more flexible, testable, and ext

  9. Human response to local convective and radiant cooling in a warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2013-01-01

    quality. The intensity of the reported sick building syndrome symptoms increased during the exposure time, with or without cooling devices in operation. Air movement had very little effect on sick building syndrome symptoms, but they increased when the pollution level was high. The lowest prevalence...... of symptoms was reported with personalized ventilation and with the radiant panel with attached fans, which also caused subjects to report less fatigue. Sick building syndrome symptoms increased most when the tabletop fan, generating movement of polluted room air, was in operation. The temperature...... of the inhaled air rather than any local cooling of the head was associated with sick building syndrome symptoms, although this needs further study. The most preferred cooling method was personalized ventilation for six subjects, fan for eight subjects, and radiant panel (or radiant panel + fans) for nine...

  10. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan

    2017-01-01

    A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large...... model was further applied to evaluate the effects of different design parameters, including the U-value of the diffuse ceiling panel, plenum height, plenum depth, and inlet configuration. In the integrated system, diffuse ceiling separated the radiant ceiling from the rest of the room and consequently...... changed the energy efficiency of the radiant system. The simulated results demonstrated that using ceiling panel with a higher U-value can minimize this impact and make the system to cool down space efficiently. Low plenum height was beneficial to the energy efficiency, but aggravated the non...

  11. Verification of Conjugate Heat Transfer Models in a Closed Volume with Radiative Heat Source

    Directory of Open Access Journals (Sweden)

    Maksimov Vyacheslav I.

    2016-01-01

    Full Text Available The results of verification of mathematical model of convective-conductive heat transfer in a closed volume with a thermally conductive enclosing structures are presented. Experiments were carried out to determine the temperature of floor premises in the working conditions of radiant heating systems. Comparison of mathematical modelling of temperature fields and experiments showed their good agreement. It is concluded that the mathematical model of conjugate heat transfers in the air cavity with a heat-conducting and heat-retaining walls correspond to the real process of formation of temperature fields in premises with gas infrared heaters system.

  12. Flammability properties and radiant fraction of FRT wood plastic composites using mass loss calorimeter under HRR hood

    Science.gov (United States)

    Mark A. Dietenberger; Charles R. Boardman; Nicole Stark

    2017-01-01

    A special test arrangement was used to assess the flammability of 4 different wood plastic composites (WPC), most with fire retardants, all of which has a tendency to high smoke production leading to high radiant energy losses to the apparatus walls. The mass loss calorimeter (MLC) was modified to include a thermopile on the exhaust pipe stack to compensate for radiant...

  13. 16 CFR Figure 4 to Subpart A of... - Flooring Radiant Panel Tester Schematic Low Flux End, Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Panel Tester Schematic Low Flux End, Elevation 4 Figure 4 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY... Standard Pt. 1209, Subpt. A, Fig. 4 Figure 4 to Subpart A of Part 1209—Flooring Radiant Panel Tester...

  14. Heat blocking gallium arsenide solar cells

    Science.gov (United States)

    Rahman, F.; Farmer, C. D.; Schmidt, C.; Pfaff, G.; Stanley, C. R.

    2008-02-01

    The solar cell industry is witnessing an era of unprecedented growth and this trend is set to continue for the foreseeable future. Here we describe a heat reflection pigment-coated single-junction gallium arsenide solar cell that is capable of reflecting heat-inducing near-infrared radiation. The cell maintains its performance better than non-coated cells when exposed to infrared-rich radiant flux. In situations where solar cells get heated mainly from incident infrared radiation, these cells exhibit superior performance. The heat reflecting pigment, cell structure, coating process and cell performance have been described.

  15. Heat Emission from a Burning Cigarette

    Directory of Open Access Journals (Sweden)

    Miura K

    2014-12-01

    Full Text Available We investigated the relationship between the smoldering burn rate and the heat transfer from a burning cigarette by measuring the heat emitted by radiation and convection, separately. The net heat generated and the net heat emitted by a burning cigarette did not vary with a change of the cigarette smoldering burn rate. The total heat emitted from a statically burning cigarette was about 50% of the total combustion heat. About 50% of the heat emitted was released as radiation heat. The smoldering burn rate did not affect the total amount of heat emitted nor the ratio of radiated heat to convected heat.

  16. Experimental Investigation of Widespread Delamination Damage to Composite Materials Caused by Radiant Heating

    Science.gov (United States)

    2013-06-30

    protruding. Figure 6. Composite plate with edge insulation ready for thermal exposure. 2.4 Tensile Testing Specimens were mounted in an MTS servo ...Tyndall AFB, FL in facilities controlled by the Air Force Research Laboratory (AFRL). Tensile and bending tests were performed using an MTS Model 244.31

  17. WaveNet

    Science.gov (United States)

    2015-10-30

    Coastal Inlets Research Program WaveNet WaveNet is a web-based, Graphical-User-Interface ( GUI ) data management tool developed for Corps coastal...generates tabular and graphical information for project planning and design documents. The WaveNet is a web-based GUI designed to provide users with a...data from different sources, and employs a combination of Fortran, Python and Matlab codes to process and analyze data for USACE applications

  18. Coloured Petri Nets

    DEFF Research Database (Denmark)

    Jensen, Kurt

    1991-01-01

    This paper describes how Coloured Petri Nets (CP-nets) have been developed — from being a promising theoretical model to being a full-fledged language for the design, specification, simulation, validation and implementation of large software systems (and other systems in which human beings and...... use of CP-nets — because it means that the function representation and the translations (which are a bit mathematically complex) no longer are parts of the basic definition of CP-nets. Instead they are parts of the invariant method (which anyway demands considerable mathematical skills...

  19. Game Coloured Petri Nets

    DEFF Research Database (Denmark)

    Westergaard, Michael

    2006-01-01

    This paper introduces the notion of game coloured Petri nets. This allows the modeler to explicitly model what parts of the model comprise the modeled system and what parts are the environment of the modeled system. We give the formal definition of game coloured Petri nets, a means of reachability...... analysis of this net class, and an application of game coloured Petri nets to automatically generate easy-to-understand visualizations of the model by exploiting the knowledge that some parts of the model are not interesting from a visualization perspective (i.e. they are part of the environment...

  20. Programming NET Web Services

    CERN Document Server

    Ferrara, Alex

    2007-01-01

    Web services are poised to become a key technology for a wide range of Internet-enabled applications, spanning everything from straight B2B systems to mobile devices and proprietary in-house software. While there are several tools and platforms that can be used for building web services, developers are finding a powerful tool in Microsoft's .NET Framework and Visual Studio .NET. Designed from scratch to support the development of web services, the .NET Framework simplifies the process--programmers find that tasks that took an hour using the SOAP Toolkit take just minutes. Programming .NET

  1. Annotating Coloured Petri Nets

    DEFF Research Database (Denmark)

    Lindstrøm, Bo; Wells, Lisa Marie

    2002-01-01

    -net. An example of such auxiliary information is a counter which is associated with a token to be able to do performance analysis. Modifying colour sets and arc inscriptions in a CP-net to support a specific use may lead to creation of several slightly different CP-nets – only to support the different uses...... a method which makes it possible to associate auxiliary information, called annotations, with tokens without modifying the colour sets of the CP-net. Annotations are pieces of information that are not essential for determining the behaviour of the system being modelled, but are rather added to support...

  2. Sensitivity analysis of the thermal performance of radiant and convective terminals for cooling buildings

    DEFF Research Database (Denmark)

    Le Dréau, J.; Heiselberg, P.

    2014-01-01

    on both radiation and convection. In order to characterise the advantages and drawbacks of the different terminals, steady-state simulations of a typical office room have been performed using four types of terminals (active chilled beam, radiant floor, wall and ceiling). A sensitivity analysis has been...

  3. Infra-red radiant intensity exposure safety study for the Eye Tracker.

    Science.gov (United States)

    Pruehsner, William R; Enderle, John D

    2005-01-01

    With any device that is used to record or evaluate biosignals, it is in the inventor's interest to determine how that device withstands a rigorous examination in regards to its inherent safety during use. For this, a Risk Management (Hazard) Analysis is a useful exercise. With this in mind, the most probable hazard concerning the Eye Tracker System (a device used to measure saccadic eye movements utilizing Reflective Differencing of Infra-Red light) is the exposure effect to the human eye caused by the Radiant Intensity of the IR emitters mounted on the Head Mounted Transducer. Presented in this article are the results of a study used to determine the Radiant Intensity exposure of the Eye Tracker as designed. Comparing these results with accepted norms for Radiant Intensity exposure, a redesign of the Head Mounted Transducer is detailed with results given showing that this new transducer fits safely into the accepted norms of Radiant Intensity exposure. Presented are the mathematical calculations used for the initial study and the redesign.

  4. Spatial distribution and temporal variability of solar radiant over southern Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Waewsak, J.; Chancham, C. [Thaksin Univ., Phatthalung (Thailand). Dept. of Physics, Renewable Energy System Research and Demonstration Center, Solar and Wind Energy Research Lab

    2009-07-01

    The potential for solar energy in Thailand has been estimated at over 50,000 MW for power generation. However, existing power plants in the country produce only 32 MW. Most the the systems have been installed in rural areas, islands and other off-grid sites. The availability and variability of global solar radiant intensity and its spatial distribution are key parameters for designing and testing outdoor solar energy systems. These parameters must be well understood in order to evaluate system efficiency at specific locations. Therefore, this study examined the spatial distribution and temporal variability of solar radiant over southern Thailand using the Surfer computer program. The incident of solar radiation on a horizontal plane was estimated at 14 synoptic stations using the Angstrom's correlation which was obtained from meteorological data. Rainfall quantity at 3 main meteorological stations was used to correlate the hours of sunshine and to predict them in meteorological stations where sunshine recorders were absent but where rainfall data were present. The 3 stations were at the Surat Thani, Phuket and Hat Yai airports. Angstrom's correlation coefficients were obtained using the correlation between the hours of sunshine and day length. The solar radiant was obtained once the extraterrestrial solar radiation was known. The study showed that the solar radiant over southern Thailand varies between 12.51 to 24.54 MJ per m{sup 2} per day. It was concluded that the temporal variation of solar radiant over southern Thailand is highly influenced by the North-East and South-West monsoons. 16 refs., 1 tab., 17 figs.

  5. Net zero water

    CSIR Research Space (South Africa)

    Lindeque, M

    2013-01-01

    Full Text Available Is it possible to develop a building that uses a net zero amount of water? In recent years it has become evident that it is possible to have buildings that use a net zero amount of electricity. This is possible when the building is taken off...

  6. Kunstige neurale net

    DEFF Research Database (Denmark)

    Hørning, Annette

    1994-01-01

    Artiklen beskæftiger sig med muligheden for at anvende kunstige neurale net i forbindelse med datamatisk procession af naturligt sprog, specielt automatisk talegenkendelse.......Artiklen beskæftiger sig med muligheden for at anvende kunstige neurale net i forbindelse med datamatisk procession af naturligt sprog, specielt automatisk talegenkendelse....

  7. Net neutrality towards a co-regulatory solution

    CERN Document Server

    Marsden, Christopher T

    2010-01-01

    In considering market developments and policy responses to some of the most heated net-neutrality debates in Europe and the United States, Net Neutrality is the first, fully comprehensive overview of the subject. This book is also unique in providing readers with a supplementary outline of recommended policy prescriptives.

  8. Thermal environment in simulated offices with convective and radiant cooling systems under cooling (summer) mode of operation

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Kostov, Kalin

    2016-01-01

    The thermal environment in a double office room and in a six-person meeting room obtained with chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and four desk partition-mounted local radiant cooling panels with mixing...... ventilation (MVRC) under summer (cooling) condition was compared. MVRC system was measured only for the office room case. CB provided convective cooling while the remaining three systems (CBR, CCMV and MVRC) provided combined radiant and convective cooling. Solar radiation, office equipment, lighting...

  9. Modelling and Simulation of the Radiant Field in an Annular Heterogeneous Photoreactor Using a Four-Flux Model

    Directory of Open Access Journals (Sweden)

    O. Alvarado-Rolon

    2018-01-01

    Full Text Available This work focuses on modeling and simulating the absorption and scattering of radiation in a photocatalytic annular reactor. To achieve so, a model based on four fluxes (FFM of radiation in cylindrical coordinates to describe the radiant field is assessed. This model allows calculating the local volumetric rate energy absorption (LVREA profiles when the reaction space of the reactors is not a thin film. The obtained results were compared to radiation experimental data from other authors and with the results obtained by discrete ordinate method (DOM carried out with the Heat Transfer Module of Comsol Multiphysics® 4.4. The FFM showed a good agreement with the results of Monte Carlo method (MC and the six-flux model (SFM. Through this model, the LVREA is obtained, which is an important parameter to establish the reaction rate equation. In this study, the photocatalytic oxidation of benzyl alcohol to benzaldehyde was carried out, and the kinetic equation for this process was obtained. To perform the simulation, the commercial software COMSOL Multiphysics v. 4.4 was employed.

  10. Pro NET Best Practices

    CERN Document Server

    Ritchie, Stephen D

    2011-01-01

    Pro .NET Best Practices is a practical reference to the best practices that you can apply to your .NET projects today. You will learn standards, techniques, and conventions that are sharply focused, realistic and helpful for achieving results, steering clear of unproven, idealistic, and impractical recommendations. Pro .NET Best Practices covers a broad range of practices and principles that development experts agree are the right ways to develop software, which includes continuous integration, automated testing, automated deployment, and code analysis. Whether the solution is from a free and

  11. Getting to Net Zero

    Energy Technology Data Exchange (ETDEWEB)

    2016-09-01

    The technology necessary to build net zero energy buildings (NZEBs) is ready and available today, however, building to net zero energy performance levels can be challenging. Energy efficiency measures, onsite energy generation resources, load matching and grid interaction, climatic factors, and local policies vary from location to location and require unique methods of constructing NZEBs. It is recommended that Components start looking into how to construct and operate NZEBs now as there is a learning curve to net zero construction and FY 2020 is just around the corner.

  12. Instant Lucene.NET

    CERN Document Server

    Heydt, Michael

    2013-01-01

    Filled with practical, step-by-step instructions and clear explanations for the most important and useful tasks. A step-by-step guide that helps you to index, search, and retrieve unstructured data with the help of Lucene.NET.Instant Lucene.NET How-to is essential for developers new to Lucene and Lucene.NET who are looking to get an immediate foundational understanding of how to use the library in their application. It's assumed you have programming experience in C# already, but not that you have experience with search techniques such as information retrieval theory (although there will be a l

  13. Net Zero Energy Buildings

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Bourrelle, Julien S.; Musall, Eike

    2010-01-01

    and identify possible renewable energy supply options which may be considered in calculations. Finally, the gap between the methodology proposed by each organisation and their respective national building code is assessed; providing an overview of the possible changes building codes will need to undergo......The international cooperation project IEA SHC Task 40 / ECBCS Annex 52 “Towards Net Zero Energy Solar Buildings”, attempts to develop a common understanding and to set up the basis for an international definition framework of Net Zero Energy Buildings (Net ZEBs). The understanding of such buildings...... parameters used in the calculations are discussed and the various renewable supply options considered in the methodologies are summarised graphically. Thus, the paper helps to understand different existing approaches to calculate energy balance in Net ZEBs, highlights the importance of variables selection...

  14. PhysioNet

    Data.gov (United States)

    U.S. Department of Health & Human Services — The PhysioNet Resource is intended to stimulate current research and new investigations in the study of complex biomedical and physiologic signals. It offers free...

  15. NetSig

    DEFF Research Database (Denmark)

    Horn, Heiko; Lawrence, Michael S; Chouinard, Candace R

    2018-01-01

    Methods that integrate molecular network information and tumor genome data could complement gene-based statistical tests to identify likely new cancer genes; but such approaches are challenging to validate at scale, and their predictive value remains unclear. We developed a robust statistic (Net......Sig) that integrates protein interaction networks with data from 4,742 tumor exomes. NetSig can accurately classify known driver genes in 60% of tested tumor types and predicts 62 new driver candidates. Using a quantitative experimental framework to determine in vivo tumorigenic potential in mice, we found that Net......Sig candidates induce tumors at rates that are comparable to those of known oncogenes and are ten-fold higher than those of random genes. By reanalyzing nine tumor-inducing NetSig candidates in 242 patients with oncogene-negative lung adenocarcinomas, we find that two (AKT2 and TFDP2) are significantly amplified...

  16. Reducing heat loss from the energy absorber of a solar collector

    Science.gov (United States)

    Chao, Bei Tse; Rabl, Ari

    1976-01-01

    A device is provided for reducing convective heat loss in a cylindrical radiant energy collector. It includes a curved reflective wall in the shape of the arc of a circle positioned on the opposite side of the exit aperture from the reflective side walls of the collector. Radiant energy exiting the exit aperture is directed by the curved wall onto an energy absorber such that the portion of the absorber upon which the energy is directed faces downward to reduce convective heat loss from the absorber.

  17. TideNet

    Science.gov (United States)

    2015-10-30

    query tide data sources in a desired geographic region of USA and its territories (Figure 1). Users can select a tide data source through the Google Map ...select data sources according to the desired geographic region. It uses the Google Map interface to display data from different sources. Recent...Coastal Inlets Research Program TideNet The TideNet is a web-based Graphical User Interface (GUI) that provides users with GIS mapping tools to

  18. Building Neural Net Software

    OpenAIRE

    Neto, João Pedro; Costa, José Félix

    1999-01-01

    In a recent paper [Neto et al. 97] we showed that programming languages can be translated on recurrent (analog, rational weighted) neural nets. The goal was not efficiency but simplicity. Indeed we used a number-theoretic approach to machine programming, where (integer) numbers were coded in a unary fashion, introducing a exponential slow down in the computations, with respect to a two-symbol tape Turing machine. Implementation of programming languages in neural nets turns to be not only theo...

  19. Interaction Nets in Russian

    OpenAIRE

    Salikhmetov, Anton

    2013-01-01

    Draft translation to Russian of Chapter 7, Interaction-Based Models of Computation, from Models of Computation: An Introduction to Computability Theory by Maribel Fernandez. "In this chapter, we study interaction nets, a model of computation that can be seen as a representative of a class of models based on the notion of 'computation as interaction'. Interaction nets are a graphical model of computation devised by Yves Lafont in 1990 as a generalisation of the proof structures of linear logic...

  20. Programming NET 35

    CERN Document Server

    Liberty, Jesse

    2009-01-01

    Bestselling author Jesse Liberty and industry expert Alex Horovitz uncover the common threads that unite the .NET 3.5 technologies, so you can benefit from the best practices and architectural patterns baked into the new Microsoft frameworks. The book offers a Grand Tour" of .NET 3.5 that describes how the principal technologies can be used together, with Ajax, to build modern n-tier and service-oriented applications. "

  1. Peculiar Features of Microclimate Formation in Heated Rooms

    Directory of Open Access Journals (Sweden)

    A. E. Zakharevich

    2009-01-01

    Full Text Available The paper presents results of microclimate simulation that have been obtained while using the developed numerical model of heat transfer in the heated rooms. The model takes into account three types of heat transfer, namely: conductive, convective and radiant. The paper contains a qualitative and quantitative analysis of the obtained data. It has been revealed that type of a heating appliance significantly influences on distribution of microclimate parameters (air temperature and mobility, surface temperature and level of heating comfort in the room. 

  2. Experimental and numerical analysis of air and radiant cooling systems in offices

    DEFF Research Database (Denmark)

    Corgnati, S. P.; Perino, M.; Fracastoro, G. V.

    2009-01-01

    This paper analyses office cooling systems based on all air mixing ventilation systems alone or coupled with radiant ceiling panels. This last solution may be effectively applied to retrofit all air systems that are no longer able to maintain a suitable thermal comfort in the indoor environment......, for example in offices with high thermal loads. This study was performed by means of CFD simulations previously validated through an experimental campaign performed in a full scale test room, simulating a typical two-desk office equipped with an all air mixing ventilation system. The numerical studies were...... then extended to the coupled mixing ventilation and cold radiant ceiling panels. In particular, attention was drawn on the evaluation of the main supply jet properties (throw and penetration length) and on the draft risk caused by the cold air drop into the occupied zone. The study shows that such a problem can...

  3. Analysis of effective radiant temperatures in a Pacific Northwest forest using Thermal Infrared Multispectral Scanner data

    Science.gov (United States)

    Sader, S. A.

    1986-01-01

    Analysis of Thermal Infrared Multispectral Scanner data collected over H. J. Andrews experimental forest in western Oregon indicated that aspect and slope gradient had a greater effect on the thermal emission of younger reforested clearcuts than of older stands. Older forest stands (older than 25 years) with greater amounts of green biomass and closed canopies, had lower effective radiant temperatures than younger, less dense stands. Aspect and slope had little effect on the effective radiant temperature of these older stands. Canopy temperature recorded at approximately 1:30 pm local time July 29, 1983 were nearly equal to maximum daily air temperature recorded at eight reference stands. The investigation provided some insights into the utility of the thermal sensor for detecting surface temperature differences related to forest composition and green biomass amounts in mountain terrain.

  4. AN INVESTIGATION ON PHOTODIODE SWITCHING TIMES FOR PULSED HIGH RADIANT POWERS

    Directory of Open Access Journals (Sweden)

    Erdem ÖZÜTÜRK

    2004-02-01

    Full Text Available In many applications the light impinging on photodiode surface is pulsed. The change in parameter values in the equivalent circuit of photodiode is important if the amplitude of light pulses are large. In this situation, the change of parameter values with the amplitude of light pulse is nonlinear. Because of this, the nonlinear model of photodiode has been used in this search. By the reasons of photoconductive operation mode is a fast operation, the photoconductive circuit has been examined. In this study, according to the nonlinear behavior of photodiode at pulsed high radiant powers the changes of switching times have been investigated by using SPICE program and the changing of switching times with increasing radiant power has been showed.

  5. The Oklahoma Field Test: Air-conditioning electricity savings from standard energy conservation measures, radiant barriers, and high-efficiency window air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, M.P.; Levins, W.P.

    1992-08-01

    A field test Involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMS) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The following conclusions were drawn from the study: (1) programs directed at reducing air-conditioning electricity consumption should be targeted at clients with high consumption to improve cost effectiveness; (2) replacing low-efficiency air conditioners with high-efficiency units should be considered an option in a weatherization program directed at reducing air-conditioning electricity consumption; (3) ECMs currently being installed under the Oklahoma WAP (chosen based on effectiveness at reducing space-heating energy consumption) should continue to be justified based on their space-heating energy savings potential only; and (4) attic radiant barriers should not be included in the Oklahoma WAP if alternatives with verified savings are available or until further testing demonstrates energy savings or other benefits in this typo of housing.

  6. The Clouds and the Earth's Radiant Energy System Elevation Bearing Assembly Life Test

    Science.gov (United States)

    Brown, Phillip L.; Miller, James B.; Jones, William R., Jr.; Rasmussen, Kent; Wheeler, Donald R.; Rana, Mauro; Peri, Frank

    1999-01-01

    The Clouds and the Earth's Radiant Energy System (CERES) elevation scan bearings lubricated with Pennzane SHF X2000 and 2% lead naphthenate (PbNp) were life tested for a seven-year equivalent Low Earth Orbit (LEO) operation. The bearing life assembly was tested continuously at an accelerated and normal rate using the scanning patterns developed for the CERES Earth Observing System AM-1 mission. A post-life-test analysis was performed on the collected data, bearing wear, and lubricant behavior.

  7. Simplified Building Thermal Model Used for Optimal Control of Radiant Cooling System

    Directory of Open Access Journals (Sweden)

    Lei He

    2016-01-01

    Full Text Available MPC has the ability to optimize the system operation parameters for energy conservation. Recently, it has been used in HVAC systems for saving energy, but there are very few applications in radiant cooling systems. To implement MPC in buildings with radiant terminals, the predictions of cooling load and thermal environment are indispensable. In this paper, a simplified thermal model is proposed for predicting cooling load and thermal environment in buildings with radiant floor. In this thermal model, the black-box model is introduced to derive the incident solar radiation, while the genetic algorithm is utilized to identify the parameters of the thermal model. In order to further validate this simplified thermal model, simulated results from TRNSYS are compared with those from this model and the deviation is evaluated based on coefficient of variation of root mean square (CV. The results show that the simplified model can predict the operative temperature with a CV lower than 1% and predict cooling loads with a CV lower than 10%. For the purpose of supervisory control in HVAC systems, this simplified RC thermal model has an acceptable accuracy and can be used for further MPC in buildings with radiation terminals.

  8. A combined approach for determining the thermal performance of radiant barriers under field conditions

    Energy Technology Data Exchange (ETDEWEB)

    Miranville, Frederic; Boyer, Harry; Lauret, Philippe; Lucas, Franck [University of La Reunion, Building and Systems Physics Laboratory, 117 rue du General Ailleret, 97 430 Le Tampon (France)

    2008-05-15

    This paper deals with a combined approach for assessing the thermal performance of radiant barriers under field conditions, based both on dynamic simulations and field measurements. The methodology involves the combination of model predictions and experimental results of a complex roof including a radiant barrier installed on a dedicated test cell. During the empirical validation of the building thermal model and more particularly thanks to the results of sensitivity analysis, simplifications of the model were made. These considerations lead to successive simplified versions of the model and finally a very simplified one, which is used to determine the thermal resistance of the complex roof. We first present the detailed thermal model, elaborated with a prototype of building simulation code. We then describe the experimental test cell and put the emphasis on the details of the roof. The simplification of the detailed model is then explained and the results presented. A value of the thermal resistance is finally obtained and confirms the potential of radiant barriers for a tropical climate. (author)

  9. Research of large scale replicate mirror of IR radiant cooler system for satellite

    Science.gov (United States)

    Liu, Guoqing; Guo, Xuejian

    2006-02-01

    Aluminum honeycomb mirror is an important component of the IR radiant cooler system employing in the aerospace applications. The radiant cooler system has a great impact on the quality of IR measurements. The quality of the mirror affects that of the radiant cooler. This article mainly introduces the manufacture of a large scale replicate mirror using thin film technology on a honeycomb-shaped aluminum plate. It discusses several technical difficulties, such as requisition of the mother board, selection of the glue and the techniques of replication on large scale aluminum plate. Borosilicate glass, which has low index of thermal expansion, is used as mother board material. It is requested to be processed to a good plane, N < or = -5, ΔN < or = 0.3.. After extensive experiments, the type of resin and solidifier and the ratio of those materials are confirmed. The selection is in consideration of the application in outer space condition and for the favor of processing big replicated mirror.

  10. Optimum comfort limits determination through the characteristics of asymmetric thermal radiation in a heated floor space, "ondol".

    Science.gov (United States)

    Yoon, Y J; Park, S D; Sohn, J Y

    1992-09-01

    This study was undertaken to evaluate the effects of the asymmetric radiation on thermal comfort, and to suggest the optimum comfort limits in a radiant heating space. The index of V.R.T. (Vector Radiant Temperature) was used to describe the environmental quality of the heated floor space. Optimum comfort limits of this space were suggested through both theoretical and empirical studies. It is recommended to use not only man's sensation of the ambient air but also that of the floor surface for the determination of the optimum comfort limits on the heated floor space such as an "Ondol" in Korea. In the present study the optimum comfort limits were suggested in terms of the V.R.T. The optimum limits obtained were as follows: the vector radiant temperature 11.0 approximately 15.0 K.

  11. High heat flux single phase heat exchanger

    Science.gov (United States)

    Valenzuela, Javier A.; Izenson, Michael G.

    1990-01-01

    This paper presents the results obtained to date in a program to develop a high heat flux, single-phase heat exchanger for spacecraft thermal management. The intended application is a net generation interface heat exchanger to couple the crew module water thermal bus to the two-phase ammonia main thermal bus in the Space Station Freedom. The large size of the interface heat exchanger is dictated by the relatively poor water-side heat transfer characteristics. The objective of this program is to develop a single-phase heat transfer approach which can achieve heat fluxes and heat transfer coefficients comparable to those of the evaporation ammonia side. A new heat exchanger concept has been developed to meet these objecties. The main feature of this heat exchanger is that it can achieve very high heat fluxes with a pressure drop one to two orders of magnitude lower than those of previous microchannel or jet impingement high heat flux heat exchangers. This paper describes proof-of-concept experiments performed in air and water and presents analytical model of the heat exchanger.

  12. Experimental studies on radiation heat transfer enhancement on a standard muffle furnace

    Directory of Open Access Journals (Sweden)

    Minea Alina Adriana

    2013-01-01

    Full Text Available One of the sources of increased industrial energy consumption is the heating equipment, e.g., furnaces. Their domain of use is very wide and due to its abundance of applications it is key equipment in modern civilization. The present experimental investigations are related to reducing energy consumptions and started from the geometry of a classic manufactured furnace. During this experimental study, different cases have been carefully chosen in order to compare and measure the effects of applying different enhancement methods of the radiation heat transfer processes. The main objective work was to evaluate the behavior of a heated enclosure, when different radiant panels were introduced. The experimental investigation showed that their efficiency was influenced by their position inside the heating area. In conclusion, changing the inner geometry by introducing radiant panels inside the heated chamber leads to important time savings in the heating process.

  13. Heat gain from thermal radiation through protective clothing with different insulation, reflectivity and vapour permeability.

    Science.gov (United States)

    Bröde, Peter; Kuklane, Kalev; Candas, Victor; Den Hartog, Emiel A; Griefahn, Barbara; Holmér, Ingvar; Meinander, Harriet; Nocker, Wolfgang; Richards, Mark; Havenith, George

    2010-01-01

    The heat transferred through protective clothing under long wave radiation compared to a reference condition without radiant stress was determined in thermal manikin experiments. The influence of clothing insulation and reflectivity, and the interaction with wind and wet underclothing were considered. Garments with different outer materials and colours and additionally an aluminised reflective suit were combined with different number and types of dry and pre-wetted underwear layers. Under radiant stress, whole body heat loss decreased, i.e., heat gain occurred compared to the reference. This heat gain increased with radiation intensity, and decreased with air velocity and clothing insulation. Except for the reflective outer layer that showed only minimal heat gain over the whole range of radiation intensities, the influence of the outer garments' material and colour was small with dry clothing. Wetting the underclothing for simulating sweat accumulation, however, caused differing effects with higher heat gain in less permeable garments.

  14. La plataforma .NET

    OpenAIRE

    Fornas Estrada, Miquel

    2008-01-01

    L'aparició de la plataforma .NET Framework ha suposat un canvi molt important en la forma de crear i distribuir aplicacions, degut a que incorpora una sèrie d'innovacions tècniques i productives que simplifiquen molt les tasques necessàries per desenvolupar un projecte. La aparición de la plataforma. NET Framework ha supuesto un cambio muy importante en la forma de crear y distribuir aplicaciones, debido a que incorpora una serie de innovaciones técnicas y productivas que simplifican mucho...

  15. Biological Petri Nets

    CERN Document Server

    Wingender, E

    2011-01-01

    It was suggested some years ago that Petri nets might be well suited to modeling metabolic networks, overcoming some of the limitations encountered by the use of systems employing ODEs (ordinary differential equations). Much work has been done since then which confirms this and demonstrates the usefulness of this concept for systems biology. Petri net technology is not only intuitively understood by scientists trained in the life sciences, it also has a robust mathematical foundation and provides the required degree of flexibility. As a result it appears to be a very promising approach to mode

  16. Calculation Tool for Determining the Net Energy Gain

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2002-01-01

    for windows are presented. Based on these methods a program has been developed that determines the heat loss coefficient, U, and the total solar energy transmittance, g, for windows compounded of specific window components selected from a database. The program calculates the net energy gain for specific....... A proper and direct way to describe the energy performance of windows is by the net energy gain, E, which expresses the energy balance for the window. It is defined as the solar heat gain transmitted in minus the heat loss transmitted out through the window during the heating season. The net energy gain...... is dependent on both the U-values and the g-values. Beyond this it is dependent on the orientation of the windows and the climate and the actual period. This makes it difficult to choose the glazings and windows that are optimal with regard to energy performance in a given case. These facts have aroused a need...

  17. Climate Model Evaluation using New Datasets from the Clouds and the Earth's Radiant Energy System (CERES)

    Science.gov (United States)

    Loeb, Norman G.; Wielicki, Bruce A.; Doelling, David R.

    2008-01-01

    There are some in the science community who believe that the response of the climate system to anthropogenic radiative forcing is unpredictable and we should therefore call off the quest . The key limitation in climate predictability is associated with cloud feedback. Narrowing the uncertainty in cloud feedback (and therefore climate sensitivity) requires optimal use of the best available observations to evaluate and improve climate model processes and constrain climate model simulations over longer time scales. The Clouds and the Earth s Radiant Energy System (CERES) is a satellite-based program that provides global cloud, aerosol and radiative flux observations for improving our understanding of cloud-aerosol-radiation feedbacks in the Earth s climate system. CERES is the successor to the Earth Radiation Budget Experiment (ERBE), which has widely been used to evaluate climate models both at short time scales (e.g., process studies) and at decadal time scales. A CERES instrument flew on the TRMM satellite and captured the dramatic 1998 El Nino, and four other CERES instruments are currently flying aboard the Terra and Aqua platforms. Plans are underway to fly the remaining copy of CERES on the upcoming NPP spacecraft (mid-2010 launch date). Every aspect of CERES represents a significant improvement over ERBE. While both CERES and ERBE measure broadband radiation, CERES calibration is a factor of 2 better than ERBE. In order to improve the characterization of clouds and aerosols within a CERES footprint, we use coincident higher-resolution imager observations (VIRS, MODIS or VIIRS) to provide a consistent cloud-aerosol-radiation dataset at climate accuracy. Improved radiative fluxes are obtained by using new CERES-derived Angular Distribution Models (ADMs) for converting measured radiances to fluxes. CERES radiative fluxes are a factor of 2 more accurate than ERBE overall, but the improvement by cloud type and at high latitudes can be as high as a factor of 5

  18. Thermal radiation heat transfer.

    Science.gov (United States)

    Siegel, R.; Howell, J. R.

    1972-01-01

    A comprehensive discussion of heat transfer by thermal radiation is presented, including the radiative behavior of materials, radiation between surfaces, and gas radiation. Among the topics considered are property prediction by electromagnetic theory, the observed properties of solid materials, radiation in the presence of other modes of energy transfer, the equations of transfer for an absorbing-emitting gas, and radiative transfer in scattering and absorbing media. Also considered are radiation exchange between black isothermal surfaces, radiation exchange in enclosures composed of diffuse gray surfaces and in enclosures having some specularly reflecting surfaces, and radiation exchange between nondiffuse nongray surfaces. The use of the Monte Carlo technique in solving radiant-exchange problems and problems of radiative transfer through absorbing-emitting media is explained.

  19. Petri Nets-Applications

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 9. Petri Nets - Applications. Y Narahari. General Article Volume 4 Issue 9 September 1999 pp 44-52. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/004/09/0044-0052. Author Affiliations. Y Narahari ...

  20. Safety nets or straitjackets?

    DEFF Research Database (Denmark)

    Ilsøe, Anna

    2012-01-01

    Does regulation of working hours at national and sector level impose straitjackets, or offer safety nets to employees seeking working time flexibility? This article compares legislation and collective agreements in the metal industries of Denmark, Germany and the USA. The industry has historically...

  1. Coloured Petri Nets

    CERN Document Server

    Jensen, Kurt

    2009-01-01

    Coloured Petri Nets (CPN) is a graphical language for modelling and validating concurrent and distributed systems, and other systems in which concurrency plays a major role. This book introduces the constructs of the CPN modelling language and presents the related analysis methods. It provides a comprehensive road map for the practical use of CPN.

  2. Boom Booom Net Radio

    DEFF Research Database (Denmark)

    Grimshaw, Mark Nicholas; Yong, Louisa; Dobie, Ian

    1999-01-01

    of an existing Internet radio station; Boom Booom Net Radio. Whilst necessity dictates some use of technology-related terminology, wherever possible we have endeavoured to keep such jargon to a minimum and to either explain it in the text or to provide further explanation in the appended glossary....

  3. Game Theory .net.

    Science.gov (United States)

    Shor, Mikhael

    2003-01-01

    States making game theory relevant and accessible to students is challenging. Describes the primary goal of GameTheory.net is to provide interactive teaching tools. Indicates the site strives to unite educators from economics, political and computer science, and ecology by providing a repository of lecture notes and tests for courses using…

  4. Coloured Petri Nets

    DEFF Research Database (Denmark)

    Jensen, Kurt; Kristensen, Lars Michael

    Coloured Petri Nets (CPN) is a graphical language for modelling and validating concurrent and distributed systems, and other systems in which concurrency plays a major role. The development of such systems is particularly challenging because of inherent intricacies like possible nondeterminism...

  5. Energy Efficient Clothes Dryer with IR Heating and Electrostatic Precipitator

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Stanton [GE Global Research, Niskayuna, NY (United States)

    2017-12-12

    portion of the program. Phase 2 of the program was structured to develop the IR heating system and then integrate it and the NESP/heat exchanger into a residential clothes dryer prototype for final testing. The proposed technology utilizes heat recovery which is known to have the biggest impact on dryer efficiency. The two current mainstream recovery approaches are air to air exchangers and heat pump condenser systems. Air to air exchanges can be very efficient but require large surface areas which are prone to fouling from uncaptured lint. Dryers based on heat pump condenser recovery systems have shown efficiency improvements of 20–60% and are commercially available. The issue with a heat pump condenser approach is the added cost, as typical prices are twice that of standard vented dryers and they are only available in small to medium capacities. The energy factor (EF) for these systems is 5.50 to 6.88 pounds/kWh compared to conventional dryers at 2.75 to 3.67 pounds/kWh. The efficiency improvements for the proposed technology come from the use of IR heating and the NESP. As the concept is in its infancy, and these improvements were difficult to predict without experimental data, assumptions were made based on available literature. IR radiant drying times, when compared to convection, are typically 30% less. This is a result of the fact that radiant energy heats directly and is absorbed at and below the surface, unlike convection heating, that must conduct the heat through the boundary film of air at the clothes surface and rely on wicking of the moisture to the surface. The second area of improvement comes from the NESP. The NESP operation is as follows: 1. Highly charged, micron sized, droplets of water are injected into the dryer exhaust by the Nebulizer. 2. These charged droplets attract water molecules and continue to grow in size, until losing their charge. During this process, latent heat is rejected back into the air stream. 3. The large droplets enter the ESP

  6. Energy performance of windows based on the net energy gain

    DEFF Research Database (Denmark)

    Svendsen, Svend; Kragh, Jesper; Laustsen, Jacob Birck

    2005-01-01

    The paper presents a new method to set up energy performance requirements and energy classes for windows of all dimensions and configurations. The net energy gain of windows is the solar gain minus the heat loss integrated over the heating season. The net energy gain can be calculated for one...... orientation or averaged over different orientations. The averaged value may be used for energy labeling of windows of standard size. Requirements in building codes may also be based on the net energy gain instead of the thermal transmittance of the window. The size and the configuration of the window, i.......e. number of glazing units, have a very large effect on the net energy gain. Therefore the energy labeling or the requirements based on the standard size may not give valid information on the energy performance of windows of non-standard size. The paper presents a method to set up requirements and classes...

  7. Food Safety Nets:

    OpenAIRE

    Haggblade, Steven; Diallo, Boubacar; Staatz, John; Theriault, Veronique; Traoré, Abdramane

    2013-01-01

    Food and social safety nets have a history as long as human civilization. In hunter gatherer societies, food sharing is pervasive. Group members who prove unlucky in the short run, hunting or foraging, receive food from other households in anticipation of reciprocal consideration at a later time (Smith 1988). With the emergence of the first large sedentary civilizations in the Middle East, administrative systems developed specifically around food storage and distribution. The ancient Egyptian...

  8. Net technical assessment

    OpenAIRE

    Wegmann, David G.

    1989-01-01

    Approved for public release; distribution is unlimited. The present and near term military balance of power between the U.S. and the Soviet Union can be expressed in a variety of net assessments. One can examine the strategic nuclear balance, the conventional balance in Europe, the maritime balance, and many others. Such assessments are essential not only for policy making but for arms control purposes and future force structure planning. However, to project the future military balance, on...

  9. Profitability of heating entrepreneurship from the viewpoint of heating energy buyer, heating energy seller and energy wood seller

    Energy Technology Data Exchange (ETDEWEB)

    Sauvula-Seppaelae, T.; Ulander, E. (Seinaejoki Univ. of Applied Sciences, Ahtari (Finland), School of Agriculture and Forestry), e-mail: tiina.sauvula-seppala@seamk.fi, e-mail: essi.ulander@seamk.fi

    2010-07-01

    The focus of this research was to study the profitability of heating entrepreneurships from the viewpoint of heating energy buyer, seller as well as energy wood seller. The average costs of heat production were Eur 44,8 / MWh and incomes Eur 43,4 /MWh. Energy wood purchase, comminution and long distance transportation formed slightly over a half of the heat production costs. Average net income in the group of the largest heating plants (>1000 kW) was Eur 29000 per year and in the group of the smallest (<200 kW) average net income was slightly over Eur 4000 per year. The net income from selling heat represents only a part of the income a heating entrepreneur receives from heat production. Other, significant parts are formed by income from selling energy wood to the plant as well as compensation for supervision and maintenance of the plant. The average net income of a forest owner from selling energy wood to heating entrepreneurs was Eur 18 / m3. Without state subsidies the net income would have been Eur 4 / m3. The price of the heating energy sold by heating entrepreneurs was very competitive. In 2006 it was Eur 30 / MWh cheaper than oil heat, Eur 34 / MWh cheaper than electric heat and Eur 3 / MWh cheaper than district heating. (orig.)

  10. Sirio.NET: A new tool for managing results in eddy current inspection of steam generators and heat exchangers; Sirio.NET: Una nueva herramienta para la gestion de resultados en las inspecciones por Corrientes Inducidas de los Generadores de Vapor y Cambiadores de Calor

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, M.; Marquez, A.; Rodriguez, A. L.

    2014-07-01

    The results management and control of the inspections by currents induced of tube bundles of components such as steam generators, heat exchangers, etc., by the large volume of data generated, requires the use of highly specialized tools of information management, based on database structures. (Author)

  11. Using WordNet for Building WordNets

    CERN Document Server

    Farreres, X; Farreres, Xavier; Rodriguez, Horacio; Rigau, German

    1998-01-01

    This paper summarises a set of methodologies and techniques for the fast construction of multilingual WordNets. The English WordNet is used in this approach as a backbone for Catalan and Spanish WordNets and as a lexical knowledge resource for several subtasks.

  12. Investigation of Low Heat Accumulation Asphalt Mixture and Its Impact on Urban Heat Environment.

    Directory of Open Access Journals (Sweden)

    Jianguang Xie

    Full Text Available This study is focused on investigating the effectiveness of low heat accumulation asphalt mixture and its impact on the urban heat environment. Infrared radiation experiments showed that the temperature of the asphalt mixture decreased with the increase in far-infrared radiant material. The results also revealed that, compared to asphalt with 0% far-infrared radiant content, the asphalt material with a certain ratio of far-infrared radiation material had higher stability at high and low temperatures as well as good water absorption capacity. The Marshall stability of the specimen mixed with 6% far-infrared radiant was higher by 12.2% and had a residual stability of up to 98.9%. Moreover, the low-temperature splitting tensile strength of the asphalt mixture with 6% far-infrared radiation material increased by 21.3%. The friction coefficient of the asphalt mixtures with 6% and 12% far-infrared radiation material increased by 17.7% and 26.9%, respectively.

  13. Building Space Heating with a Solar-Assisted Heat Pump Using Roof-Integrated Solar Collectors

    Directory of Open Access Journals (Sweden)

    Zhiyong Yang

    2011-03-01

    Full Text Available A solar assisted heat pump (SAHP system was designed by using a roof-integrated solar collector as the evaporator, and then it was demonstrated to provide space heating for a villa in Tianjin, China. A building energy simulation tool was used to predict the space heating load and a three dimensional theoretical model was established to analyze the heat collection performance of the solar roof collector. A floor radiant heating unit was used to decrease the energy demand. The measurement results during the winter test period show that the system can provide a comfortable living space in winter, when the room temperature averaged 18.9 °C. The average COP of the heat pump system is 2.97 and with a maximum around 4.16.

  14. Dynamic behavior of radiant cooling system based on capillary tubes in walls made of high performance concrete

    DEFF Research Database (Denmark)

    Mikeska, Tomás; Svendsen, Svend

    2015-01-01

    using cooling water for the radiant cooling system with a temperature only about 4K lower than the temperature of the room air. The relatively high speed reaction of the designed system is a result of the slim construction of the sandwich wall elements made of high performance concrete. (C) 2015...... the small amount of fresh air required by standards to provide a healthy indoor environment.This paper reports on experimental analyses evaluating the dynamic behavior of a test room equipped with a radiant cooling system composed of plastic capillary tubes integrated into the inner layer of sandwich wall...... elements made of high performance concrete. The influence of the radiant cooling system on the indoor climate of the test room in terms of the air, surface and operative temperatures and velocities was investigated.The results show that the temperature of the room air can be kept in a comfortable range...

  15. Use of local convective and radiant cooling at warm environment: effect on thermal comfort and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Duszyk, Marcin; Krejcirikova, Barbora

    2012-01-01

    The effect of four local cooling devices (convective, radiant and combined) on thermal comfort and perceived air quality reported by 24 subjects at 28 ˚C and 50% RH was studied. The devices studied were: (1) desk cooling fan, (2) personalized ventilation providing clean air, (3) two radiant panels...... and (4) two radiant panels with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (pthermal comfort...... compared to without cooling. The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The improvement in PAQ...

  16. Light-emitting-diode Lambertian light sources as low-radiant-flux standards applicable to quantitative luminescence-intensity imaging

    Science.gov (United States)

    Yoshita, Masahiro; Kubota, Hidehiro; Shimogawara, Masahiro; Mori, Kaneo; Ohmiya, Yoshihiro; Akiyama, Hidefumi

    2017-09-01

    Planar-type Lambertian light-emitting diodes (LEDs) with a circular aperture of several tens of μ m to a few mm in diameter were developed for use as radiant-flux standard light sources, which have been in strong demand for applications such as quantitative or absolute intensity measurements of weak luminescence from solid-state materials and devices. Via pulse-width modulation, time-averaged emission intensity of the LED devices was controlled linearly to cover a wide dynamic range of about nine orders of magnitude, from 10 μ W down to 10 fW. The developed planar LED devices were applied as the radiant-flux standards to quantitative measurements and analyses of photoluminescence (PL) intensity and PL quantum efficiency of a GaAs quantum-well sample. The results demonstrated the utility and applicability of the LED standards in quantitative luminescence-intensity measurements in Lambertian-type low radiant-flux level sources.

  17. GAM-HEAT: A computer code to compute heat transfer in complex enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.E.; Taylor, J.R.

    1992-12-01

    This report discusses the GAM[underscore]HEAT code which was developed for heat transfer analyses associated with postulated Double Ended Guilliotine Break Loss Of Coolant Accidents (DEGB LOCA) resulting in a drained reactor vessel. In these analyses the gamma radiation resulting from fission product decay constitutes the primary source of energy as a function of time. This energy is deposited into the various reactor components and is re-radiated as thermal energy. The code accounts for all radiant heat exchanges within and leaving the reactor enclosure. The SRS reactors constitute complex radiant exchange enclosures since there are many assemblies of various types within the primary enclosure and most of the assemblies themselves constitute enclosures. GAM-HEAT accounts for this complexity by processing externally generated view factors and connectivity matrices as discussed below, and also accounts for convective, conductive, and advective heat exchanges. The code is structured such that it is applicable for many situations involving heat exchange between surfaces within a radiatively passive medium.

  18. GAM-HEAT: A computer code to compute heat transfer in complex enclosures. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.E.; Taylor, J.R.

    1992-12-01

    This report discusses the GAM{underscore}HEAT code which was developed for heat transfer analyses associated with postulated Double Ended Guilliotine Break Loss Of Coolant Accidents (DEGB LOCA) resulting in a drained reactor vessel. In these analyses the gamma radiation resulting from fission product decay constitutes the primary source of energy as a function of time. This energy is deposited into the various reactor components and is re-radiated as thermal energy. The code accounts for all radiant heat exchanges within and leaving the reactor enclosure. The SRS reactors constitute complex radiant exchange enclosures since there are many assemblies of various types within the primary enclosure and most of the assemblies themselves constitute enclosures. GAM-HEAT accounts for this complexity by processing externally generated view factors and connectivity matrices as discussed below, and also accounts for convective, conductive, and advective heat exchanges. The code is structured such that it is applicable for many situations involving heat exchange between surfaces within a radiatively passive medium.

  19. Curing characteristics of a composite - part 1: cure depth relationship to conversion, hardness and radiant exposure.

    Science.gov (United States)

    Erickson, Robert L; Barkmeier, Wayne W; Halvorson, Rolf H

    2014-06-01

    As the first part of a larger study on curing characteristics of a resin-based composite (RBC), the major objectives were to create an energy-hardness relationship (EHR) that relates Knoop hardness (KHN) with radiant exposure (H), and to do the same for degree of conversion (DC) in the form of an energy-conversion relationship (ECR). Both of these are meant to be universal relationships that satisfy reciprocity between irradiance and time for a given H value. RBC specimens were made by curing the material in 6mm diameter, stainless steel molds for 10-40s and allowing the material to cure for 24h. Cure depths were determined by a scrape-back method. KHN and DC values were determined along the central axis of the specimens, and these values were related to the internal H values using a measured transmission relationship, T(d), for the RBC. Suitable EHR and ECR relationships were developed for the RBC material that can be used to describe the curing characteristics under various curing conditions. However, predictive accuracy is affected for incident radiant exposures below about 12J/cm(2) to some extent. A relationship between KHN and DC was established. For the RBC examined, KHN measurements can be used as an alternate method or in conjunction with DC for describing the curing characteristics. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  20. Proof nets for lingusitic analysis

    NARCIS (Netherlands)

    Moot, R.C.A.

    2002-01-01

    This book investigates the possible linguistic applications of proof nets, redundancy free representations of proofs, which were introduced by Girard for linear logic. We will adapt the notion of proof net to allow the formulation of a proof net calculus which is soundand complete for the

  1. Teaching Tennis for Net Success.

    Science.gov (United States)

    Young, Bryce

    1989-01-01

    A program for teaching tennis to beginners, NET (Net Easy Teaching) is described. The program addresses three common needs shared by tennis students: active involvement in hitting the ball, clearing the net, and positive reinforcement. A sample lesson plan is included. (IAH)

  2. Net4Care Ecosystem Website

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius; Rasmussen, Morten

    2012-01-01

    is a tele-monitoring scenario in which Net4Care clients are deployed in a gateway in private homes. Medical devices then connect to these gateways and transmit their observations to a Net4Care server. In turn the Net4Care server creates valid clinical HL7 documents, stores them in a national XDS repository...

  3. Thermal Performance Testing of Cryogenic Multilayer Insulation with Silk Net Spacers

    Science.gov (United States)

    Johnson, W. L.; Frank, D. J.; Nast, T. C.; Fesmire, J. E.

    2015-12-01

    Early comprehensive testing of cryogenic multilayer insulation focused on the use of silk netting as a spacer material. Silk netting was used for multiple test campaigns that were designed to provide baseline thermal performance estimates for cryogenic insulation systems. As more focus was put on larger systems, the cost of silk netting became a deterrent and most aerospace insulation firms were using Dacron (or polyester) netting spacers by the early 1970s. In the midst of the switch away from silk netting there was no attempt to understand the difference between silk and polyester netting, though it was widely believed that the silk netting provided slightly better performance. Without any better reference for thermal performance data, the silk netting performance correlations continued to be used. In order to attempt to quantify the difference between the silk netting and polyester netting, a brief test program was developed. The silk netting material was obtained from Lockheed Martin and was tested on the Cryostat-100 instrument in three different configurations, 20 layers with both single and double netting and 10 layers with single netting only. The data show agreement within 15 - 30% with the historical silk netting based correlations and show a substantial performance improvement when compared to previous testing performed using polyester netting and aluminum foil/fiberglass paper multilayer insulation. Additionally, the data further reinforce a recently observed trend that the heat flux is not directly proportional to the number of layers installed on a system.

  4. Antena impresa para comunicaciones por satélite en banda Ka: Esquema de array y elementos radiantes

    OpenAIRE

    Martínez Osete, Beatriz

    2015-01-01

    Este trabajo fin de grado versa sobre el diseño y simulación del elemento radiante de una antena impresa con polarización circular, operativa en la banda Ka de frecuencias (18 – 31 GHz) para un sistema de comunicaciones entre aviones y satélites. Su principal característica es que la antena está formada por placas de circuito impreso apiladas. En las placas superiores se sitúan los elementos radiantes, mientras que en las capas internas se diseñan las líneas de transmisión, que forman la alim...

  5. Master Robotic Net

    Directory of Open Access Journals (Sweden)

    Vladimir Lipunov

    2010-01-01

    Full Text Available The main goal of the MASTER-Net project is to produce a unique fast sky survey with all sky observed over a single night down to a limiting magnitude of 19-20. Such a survey will make it possible to address a number of fundamental problems: search for dark energy via the discovery and photometry of supernovae (including SNIa, search for exoplanets, microlensing effects, discovery of minor bodies in the Solar System, and space-junk monitoring. All MASTER telescopes can be guided by alerts, and we plan to observe prompt optical emission from gamma-ray bursts synchronously in several filters and in several polarization planes.

  6. Art/Net/Work

    DEFF Research Database (Denmark)

    Andersen, Christian Ulrik; Lindstrøm, Hanne

    2006-01-01

    The seminar Art|Net|Work deals with two important changes in our culture. On one side, the network has become essential in the latest technological development. The Internet has entered a new phase, Web 2.0, including the occurrence of as ‘Wiki’s’, ‘Peer-2-Peer’ distribution, user controlled...... the praxis of the artist. We see different kinds of interventions and activism (including ‘hacktivism’) using the network as a way of questioning the invisible rules that govern public and semi-public spaces. Who ‘owns’ them? What kind of social relationships do they generate? On what principle...

  7. Helminth.net: expansions to Nematode.net and an introduction to Trematode.net

    Science.gov (United States)

    Martin, John; Rosa, Bruce A.; Ozersky, Philip; Hallsworth-Pepin, Kymberlie; Zhang, Xu; Bhonagiri-Palsikar, Veena; Tyagi, Rahul; Wang, Qi; Choi, Young-Jun; Gao, Xin; McNulty, Samantha N.; Brindley, Paul J.; Mitreva, Makedonka

    2015-01-01

    Helminth.net (http://www.helminth.net) is the new moniker for a collection of databases: Nematode.net and Trematode.net. Within this collection we provide services and resources for parasitic roundworms (nematodes) and flatworms (trematodes), collectively known as helminths. For over a decade we have provided resources for studying nematodes via our veteran site Nematode.net (http://nematode.net). In this article, (i) we provide an update on the expansions of Nematode.net that hosts omics data from 84 species and provides advanced search tools to the broad scientific community so that data can be mined in a useful and user-friendly manner and (ii) we introduce Trematode.net, a site dedicated to the dissemination of data from flukes, flatworm parasites of the class Trematoda, phylum Platyhelminthes. Trematode.net is an independent component of Helminth.net and currently hosts data from 16 species, with information ranging from genomic, functional genomic data, enzymatic pathway utilization to microbiome changes associated with helminth infections. The databases’ interface, with a sophisticated query engine as a backbone, is intended to allow users to search for multi-factorial combinations of species’ omics properties. This report describes updates to Nematode.net since its last description in NAR, 2012, and also introduces and presents its new sibling site, Trematode.net. PMID:25392426

  8. INVESTIGATION OF METAL CHIP HEATING PROCESS (Part 2

    Directory of Open Access Journals (Sweden)

    O. M. Dyakonov

    2008-01-01

    Full Text Available A physical and mathematical model of metal chip heating process in a continuous muffle furnace has been worked out. The model describes a conjugated heat- and mass transfer in the given  furnace (conductive, convective, radiant, heating of chips and furnace parts, lubricant-coolant evaporation, oil vapour combustion, flue gas movement. The received set of equations is a completed one that allows to solve a specified problem that is to find an optimum height for a furnace with the given productivity  and minimum natural gas consumption. 

  9. NETS FOR PEACH PROTECTED CULTIVATION

    Directory of Open Access Journals (Sweden)

    Evelia Schettini

    2012-06-01

    Full Text Available The aim of this paper was to investigate the radiometric properties of coloured nets used to protect a peach cultivation. The modifications of the solar spectral distribution, mainly in the R and FR wavelength band, influence plant photomorphogenesis by means of the phytochrome and cryptochrome. The phytochrome response is characterized in terms of radiation rate in the red wavelengths (R, 600-700 nm to that in the farred radiation (FR, 700-800 nm, i.e. the R/FR ratio. The effects of the blue radiation (B, 400-500 nm is investigated by the ratio between the blue radiation and the far-red radiation, i.e. the B/FR ratio. A BLUE net, a RED net, a YELLOW net, a PEARL net, a GREY net and a NEUTRAL net were tested in Bari (Italy, latitude 41° 05’ N. Peach trees were located in pots inside the greenhouses and in open field. The growth of the trees cultivated in open field was lower in comparison to the growth of the trees grown under the nets. The RED, PEARL, YELLOW and GREY nets increased the growth of the trees more than the other nets. The nets positively influenced the fruit characteristics, such as fruit weight and flesh firmness.

  10. Molecular heat pump

    OpenAIRE

    Segal, Dvira; Nitzan, Abraham

    2005-01-01

    We propose a novel molecular device that pumps heat against a thermal gradient. The system consists of a molecular element connecting two thermal reservoirs that are characterized by different spectral properties. The pumping action is achieved by applying an external force that periodically modulates molecular levels. This modulation affects periodic oscillations of the internal temperature of the molecule and the strength of its coupling to each reservoir resulting in a net heat flow in the...

  11. Smart Control of Air Climatization System in Function on the Values of Mean Local Radiant Temperature

    Directory of Open Access Journals (Sweden)

    Giuseppe Cannistraro

    2015-08-01

    Full Text Available The hygrothermal comfort indoor conditions are defined as: those environmental conditions in which an individual exposed, expresses a state of satisfaction. These conditions cannot always be achieved anywhere in an optimal way and economically; in some cases they can be obtained only in work environments specific areas. This could be explained because of air conditioning systems designing is generally performed both on the basis of the fundamental parameters’ average values, such as temperature, velocity and relative humidity (Ta, va e φa and derived parameters such as operating temperature and mean radiant one (Top eTmr. However, in some specific cases - large open-spaces or in case of radiating surfaces - the descriptors defining indoor comfort conditions, based on average values, do not provide the optimum values required during the air conditioning systems design phase. This is largely due to the variability of real environmental parameters values compared to the average ones taken as input in the calculation. The results obtained in previous scientific papers on the thermal comfort have been the driving element of this work. It offers a simple, original and clever way of thinking about the new domotic systems for air conditioning, based on the “local mean radiant temperature.” This is a very important parameter when one wants to analyze comfort in environments characterized by the presence of radiating surfaces, as will be seen hereinafter. In order to take into account the effects of radiative exchanges in the open-space workplace, where any occupant may find themselves in different temperature and humidity conditions, this paper proposes an action on the domotic climate control, with ducts and vents air distribution placed in different zones. Comparisons were performed between the parameters values representing the punctual thermal comfort, with the Predicted Mean Vote PMV, in an environment marked by radiating surfaces (i

  12. The equivalency between logic Petri workflow nets and workflow nets.

    Science.gov (United States)

    Wang, Jing; Yu, ShuXia; Du, YuYue

    2015-01-01

    Logic Petri nets (LPNs) can describe and analyze batch processing functions and passing value indeterminacy in cooperative systems. Logic Petri workflow nets (LPWNs) are proposed based on LPNs in this paper. Process mining is regarded as an important bridge between modeling and analysis of data mining and business process. Workflow nets (WF-nets) are the extension to Petri nets (PNs), and have successfully been used to process mining. Some shortcomings cannot be avoided in process mining, such as duplicate tasks, invisible tasks, and the noise of logs. The online shop in electronic commerce in this paper is modeled to prove the equivalence between LPWNs and WF-nets, and advantages of LPWNs are presented.

  13. The Effects of Mean Radiant Temperature on Thermal Comfort, Energy Consumption and Control – A Critical Overview

    NARCIS (Netherlands)

    V. Soebarto; J. van Hoof; E. Halawa

    2014-01-01

    Halawa, E., van Hoof, J., Soebarto, V. (2014) The Effects of Mean Radiant Temperature on Thermal Comfort, Energy Consumption and Control – A Critical Overview. Renewable & Sustainable Energy Review 37:907-918 doi: 10.1016/j.rser.2014.05.040

  14. Where the Solar system meets the solar neighbourhood: patterns in the distribution of radiants of observed hyperbolic minor bodies

    Science.gov (United States)

    de la Fuente Marcos, Carlos; de la Fuente Marcos, Raúl; Aarseth, Sverre J.

    2018-02-01

    Observed hyperbolic minor bodies might have an interstellar origin, but they can be natives of the Solar system as well. Fly-bys with the known planets or the Sun may result in the hyperbolic ejection of an originally bound minor body; in addition, members of the Oort cloud could be forced to follow inbound hyperbolic paths as a result of secular perturbations induced by the Galactic disc or, less frequently, due to impulsive interactions with passing stars. These four processes must leave distinctive signatures in the distribution of radiants of observed hyperbolic objects, both in terms of coordinates and velocity. Here, we perform a systematic numerical exploration of the past orbital evolution of known hyperbolic minor bodies using a full N-body approach and statistical analyses to study their radiants. Our results confirm the theoretical expectations that strong anisotropies are present in the data. We also identify a statistically significant overdensity of high-speed radiants towards the constellation of Gemini that could be due to the closest and most recent known fly-by of a star to the Solar system, that of the so-called Scholz's star. In addition to and besides 1I/2017 U1 (`Oumuamua), we single out eight candidate interstellar comets based on their radiants' velocities.

  15. A METHOD FOR EVALUATION OF NON-UNIFORM RADIANT-CONVECTIVE LOAD ON HUMAN BODY DURING MENTAL WORK

    Directory of Open Access Journals (Sweden)

    Lenka Prokšová Zuská

    2017-10-01

    Full Text Available The objective of this study was to develop a documentation for the amendment of the microclimatic part of the Czech Government Regulation, particularly in a non-uniform radiant-convective load evaluation. Changes in regulation were made based on experimental data obtained on a group of experimental individuals in a climatic chamber. One of the objectives of the climatic chamber experiments was to evaluate whether there was a possibility to use an alternative method, which utilizes a new value – stereotemperature, for the assessment. A group of 24 women was exposed to a non-uniform radiant-convective load in a climatic chamber for 1 hour during their computer work. Measurements were divided according to the globe temperature into 3 stages. The physical parameters of air were continuously measured: the air temperature, globe temperature, air velocity, radiant temperature, relative humidity, stereotemperature and physiological parameters. Thermal sensations of experimental subjects were expressed in the seven-point scale according to EN ISO 7730. The thermal sensation correlated very well with the difference of stereotemperature and the globe temperature. The stereotemperature correlated very well with the radiant temperature. In this work, the composed equations were used to develop the limit values for the thermal stress evaluation in the uniform and non-uniform thermal environment at workplaces. It is possible to determine how the body of an exposed person perceives the non-uniform climatic conditions in the indoor environment, by adding the stereotemperature to government regulations.

  16. Health-related quality of life for everolimus versus placebo in patients with advanced, non-functional, well-differentiated gastrointestinal or lung neuroendocrine tumours (RADIANT-4): a multicentre, randomised, double-blind, placebo-controlled, phase 3 trial.

    Science.gov (United States)

    Pavel, Marianne E; Singh, Simron; Strosberg, Jonathan R; Bubuteishvili-Pacaud, Lida; Degtyarev, Evgeny; Neary, Maureen P; Carnaghi, Carlo; Tomasek, Jiri; Wolin, Edward; Raderer, Markus; Lahner, Harald; Valle, Juan W; Pommier, Rodney; Van Cutsem, Eric; Tesselaar, Margot E T; Fave, Gianfranco Delle; Buzzoni, Roberto; Hunger, Matthias; Eriksson, Jennifer; Cella, David; Ricci, Jean-François; Fazio, Nicola; Kulke, Matthew H; Yao, James C

    2017-10-01

    In the phase 3 RADIANT-4 trial, everolimus increased progression-free survival compared with placebo in patients with advanced, progressive, non-functional, well-differentiated gastrointestinal or lung neuroendocrine tumours (NETs). We now report the health-related quality of life (HRQOL) secondary endpoint. RADIANT-4 is a multicentre, randomised, double-blind, placebo-controlled, phase 3 trial done in 97 centres in 25 countries worldwide. Adults (aged ≥18 years) were eligible for the study if they had pathologically confirmed, advanced (unresectable or metastatic), non-functional, well-differentiated (grade 1 or 2) NETs of lung or gastrointestinal origin. Patients were randomly allocated (2:1) using block randomisation (block size of three) by an interactive voice response system to receive oral everolimus (10 mg per day) or placebo, both with best supportive care, with stratification by tumour origin, WHO performance status, and previous somatostatin analogue treatment. HRQOL was assessed with the Functional Assessment of Cancer Therapy-General (FACT-G) questionnaire at baseline (visit 2, day 1), every 8 weeks (± 1 week) during the study for the first 12 months after randomisation, and every 12 weeks thereafter until study drug discontinuation. The primary endpoint, reported previously, was progression-free survival assessed by central review; HRQOL was a prespecified secondary endpoint. The prespecified secondary outcome measure was time to definitive deterioration (≥7 points) in FACT-G total score. Analyses were done on the full analysis set, consisting of all randomised patients, by intention to treat. Only data obtained while receiving the randomly allocated treatment were included in this analysis. Enrolment for RADIANT-4 was completed on Aug 23, 2013, but the trial is ongoing pending final analysis of the key secondary endpoint of overall survival. This trial is registered with ClinicalTrials.gov, number NCT01524783. Between April 3, 2012, and Aug 23

  17. Coloured Petri Nets

    DEFF Research Database (Denmark)

    Jensen, Kurt; Kristensen, Lars Michael

    studies that illustrate the practical use of CPN modelling and validation for design, specification, simulation, verification and implementation in various application domains. Their presentation primarily aims at readers interested in the practical use of CPN. Thus all concepts and constructs are first......Coloured Petri Nets (CPN) is a graphical language for modelling and validating concurrent and distributed systems, and other systems in which concurrency plays a major role. The development of such systems is particularly challenging because of inherent intricacies like possible nondeterminism...... and the immense number of possible execution sequences. In this textbook, Jensen and Kristensen introduce the constructs of the CPN modelling language and present the related analysis methods in detail. They also provide a comprehensive road map for the practical use of CPN by showcasing selected industrial case...

  18. Heat Transfer in Human Skin Exposed to Radiation from Forest Fire Taking Into Account Moisture Evaporation

    Directory of Open Access Journals (Sweden)

    Poptsov Nikolay

    2017-01-01

    Full Text Available Thermal radiation is one of the damaging factors of forest fire. As a result of exposure to radiant heat flow, thermal damage of the human skin is possible. A layer of skin is considered with effective thermophysical characteristics. Thin layer of sweat excretion situated on top of the skin. A mathematical model of heat transfer in the system of “skin-excretion” is developed taking into account evaporation of moisture. Typical simulation results are presented.

  19. An Integrated Control System for Heating and Indoor Climate Applications

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh

    2012-01-01

    Low temperature hydronic heating and cooling systems connected to renewable energy sources have gained more attention in the recent decades. This is due to the growing public awareness of the adverse environmental impacts of energy generation using fossil fuel. Radiant hydronic sub-floor heating...... in terms of energy efficiency, associated energy cost and occupants’ thermal comfort is the main objective to be fulfilled via design of an integrated controller. We also proposed control strategies to manage energy consumption of the building to turn domestic heat demands into a flexible load in the smart...... which geothermal heat pump, solar driven heat pumps and the other types are categorized as renewable or renewable energy sources. In the present study, we investigated modeling and control of hydronic heat emitters integrated with a ground-source heat pump. Optimization of the system performance...

  20. Mars MetNet Mission Status

    Science.gov (United States)

    Harri, Ari-Matti; Aleksashkin, Sergei; Arruego, Ignacio; Schmidt, Walter; Genzer, Maria; Vazquez, Luis; Haukka, Harri

    2015-04-01

    New kind of planetary exploration mission for Mars is under development in collaboration between the Finnish Meteorological Institute (FMI), Lavochkin Association (LA), Space Research Institute (IKI) and Institutio Nacional de Tecnica Aerospacial (INTA). The Mars MetNet mission is based on a new semi-hard landing vehicle called MetNet Lander (MNL). The scientific payload of the Mars MetNet Precursor [1] mission is divided into three categories: Atmospheric instruments, Optical devices and Composition and structure devices. Each of the payload instruments will provide significant insights in to the Martian atmospheric behavior. The key technologies of the MetNet Lander have been qualified and the electrical qualification model (EQM) of the payload bay has been built and successfully tested. 1. MetNet Lander The MetNet landing vehicles are using an inflatable entry and descent system instead of rigid heat shields and parachutes as earlier semi-hard landing devices have used. This way the ratio of the payload mass to the overall mass is optimized. The landing impact will burrow the payload container into the Martian soil providing a more favorable thermal environment for the electronics and a suitable orientation of the telescopic boom with external sensors and the radio link antenna. It is planned to deploy several tens of MNLs on the Martian surface operating at least partly at the same time to allow meteorological network science. 2. Scientific Payload The payload of the two MNL precursor models includes the following instruments: Atmospheric instruments: 1. MetBaro Pressure device 2. MetHumi Humidity device 3. MetTemp Temperature sensors Optical devices: 1. PanCam Panoramic 2. MetSIS Solar irradiance sensor with OWLS optical wireless system for data transfer 3. DS Dust sensor The descent processes dynamic properties are monitored by a special 3-axis accelerometer combined with a 3-axis gyrometer. The data will be sent via auxiliary beacon antenna throughout the

  1. Clouds and the Earth's Radiant Energy System (CERES) Data Products for Climate Research

    Science.gov (United States)

    Kato, Seiji; Loeb, Norman G.; Rutan, David A.; Rose, Fred G.

    2015-01-01

    NASA's Clouds and the Earth's Radiant Energy System (CERES) project integrates CERES, Moderate Resolution Imaging Spectroradiometer (MODIS), and geostationary satellite observations to provide top-of-atmosphere (TOA) irradiances derived from broadband radiance observations by CERES instruments. It also uses snow cover and sea ice extent retrieved from microwave instruments as well as thermodynamic variables from reanalysis. In addition, these variables are used for surface and atmospheric irradiance computations. The CERES project provides TOA, surface, and atmospheric irradiances in various spatial and temporal resolutions. These data sets are for climate research and evaluation of climate models. Long-term observations are required to understand how the Earth system responds to radiative forcing. A simple model is used to estimate the time to detect trends in TOA reflected shortwave and emitted longwave irradiances.

  2. Numerical study of influence of different dispersed components of crystal cloud on transmission of radiant energy

    Science.gov (United States)

    Shefer, Olga

    2017-11-01

    The calculated results of the transmission of visible and infrared radiation by an atmosphere layer involving ensembles of large preferentially oriented crystals and spherical particles are presented. To calculate extinction characteristics, the physical optics method and the Mie theory are applied. Among all atmospheric particles, both the small particles that are commensurable with the wavelength of the incident radiation and the large plates and the columns are distinguished by the most pronounced dependence of the transmission on spectra of radiant energy. The work illustrates features of influence of parameters of the particle size distribution, particle aspect ratios, orientation and particle refractive index, also polarization state of the incident radiation on the transmission. The predominant effect of the plates on the wavelength dependence of the transmission is shown. A separated and cooperative contributes of the large plates and the small volume shape particles to the common transmission by medium are considered.

  3. Determination of Unfiltered Radiances from the Clouds and the Earth's Radiant Energy System (CERES) Instrument

    Science.gov (United States)

    Loeb, N. G.; Priestley, K. J.; Kratz, D. P.; Geier, E. B.; Green, R. N.; Wielicki, B. A.; Hinton, P. OR.; Nolan, S. K.

    2001-01-01

    A new method for determining unfiltered shortwave (SW), longwave (LW) and window (W) radiances from filtered radiances measured by the Clouds and the Earth's Radiant Energy System (CERES) satellite instrument is presented. The method uses theoretically derived regression coefficients between filtered and unfiltered radiances that are a function of viewing geometry, geotype and whether or not cloud is present. Relative errors in insta.ntaneous unfiltered radiances from this method are generally well below 1% for SW radiances (approx. 0.4% 1(sigma) or approx.l W/sq m equivalent flux), < 0.2% for LW radiances (approx. 0.1% 1(sigma) or approx.0.3 W/sq m equivalent flux) and < 0.2% (approx. 0.1% 1(sigma) for window channel radiances.

  4. Radiant thinking and the use of the mind map in nurse practitioner education.

    Science.gov (United States)

    Spencer, Julie R; Anderson, Kelley M; Ellis, Kathryn K

    2013-05-01

    The concept of radiant thinking, which led to the concept of mind mapping, promotes all aspects of the brain working in synergy, with thought beginning from a central point. The mind map, which is a graphical technique to improve creative thinking and knowledge attainment, utilizes colors, images, codes, and dimensions to amplify and enhance key ideas. This technique augments the visualization of relationships and links between concepts, which aids in information acquisition, data retention, and overall comprehension. Faculty can promote students' use of the technique for brainstorming, organizing ideas, taking notes, learning collaboratively, presenting, and studying. These applications can be used in problem-based learning, developing plans of care, health promotion activities, synthesizing disease processes, and forming differential diagnoses. Mind mapping is a creative way for students to engage in a unique method of learning that can expand memory recall and help create a new environment for processing information. Copyright 2013, SLACK Incorporated.

  5. The Oklahoma Field Test: Air-Conditioning Electricity Savings from Standard Energy Conservation Measures, Radiant Barriers, and High-Efficiency Window Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, M.P.

    1992-01-01

    general replacement of low-efficiency air conditioners (replacing units in all houses without considering pre-weatherization air-conditioning electricity consumption) was not cost effective in the test houses. ECMs installed under the Oklahoma WAP and installed in combination with an attic radiant barrier did not produce air-conditioning electricity savings that could be measured in the field test. The following conclusions were drawn from the study: (1) programs directed at reducing air-conditioning electricity consumption should be targeted at clients with high consumption to improve cost effectiveness; (2) replacing low-efficiency air conditioners with high-efficiency units should be considered an option in a weatherization program directed at reducing air-conditioning electricity consumption; (3) ECMs currently being installed under the Oklahoma WAP (chosen based on effectiveness at reducing space-heating energy consumption) should continue to be justified based on their space-heating energy savings potential only; and (4) attic radiant barriers should not be included in the Oklahoma WAP if alternatives with verified savings are available or until further testing demonstrates energy savings or other benefits in this type of housing.

  6. Photosynthesis and leaf morphology of Liquidambar styraciflua L. under variable urban radiant-energy conditions

    Science.gov (United States)

    Kjelgren, Roger K.; Clark, James R.

    1992-09-01

    Diminished sunlight, characteristic of urban canyons, has been suggested as being potentially limiting to plant growth. This study investigated the response of sweetgum ( Liquidambar styraciflua L.) to variable irradiance in a range of urban locations. Diurnal photosynthesis was measured in situ on mature trees, comparing an open site at an urban park with an urban canyon that received 4 h of midday sun in midsummer. Photosynthesis for trees growing in the canyon was lower both during shaded and sunlit periods compared with trees at the park. Photosynthesis of detached shoots in a growth chamber was greater in canyon than park foliage at low irradiance, indicating possible photosynthetic shade acclimation analogous to tree species growing in the forest understorey. Shoot and trunk growth and morphological characteristics were measured on L. styraciflua growing along boulevards at 15 additional urban sites and related to seasonal interception of solar radiation. Angular elevation and orientation of buildings and trees that defined the horizon topography at each site were used in modeling the potential irradiance of global shortwave radiation. Seasonal irradiance among sites ranged from 21% in the urban core to nearly 95% in outlying residential districts of that potentially received under an unobstructed horizon. Shade acclimation was confirmed by differences in leaf morphology, as foliage became flatter, thinner, and more horizontally oriented at sites with lower irradiance. Photosynthetic and morphological acclimation to shade did not compensate for lower available radiant energy as both shoot and trunk growth decreased at sites of lower irradiance. Unlike the forest understorey, the static light environment of urban canyons may subject shade-intolerant species such as L. styraciflua to chronic, low-radiant-energy stress.

  7. Polymerization stress related to radiant exposure and its effect on microleakage of composite restorations.

    Science.gov (United States)

    Calheiros, Fernanda Calabró; Sadek, Fernanda Tranchesi; Boaro, Leticia Cristina Cidreira; Braga, Roberto Ruggiero

    2007-12-01

    Verify the influence of radiant exposure (dose) on polymerization stress and microleakage of composite restorations using two adhesive systems. An experimental composite (1BisGMA:1TEGDMA, 75wt.% filler) was subjected to 3, 6, 12 or 24J/cm(2) under 500mW/cm(2). Stress was measured in 1-mm height specimens placed between two glass rods (Ø=5mm) attached to a testing machine. Microleakage was assessed in cylindrical restorations (Ø=5mm, h=2mm) with enamel margins, using Adper Single Bond 2 (SB) or Adper Prompt (PR). After storage, specimens were subjected to dye penetration (50% AgNO(3)) and sectioned twice, perpendicularly. Microleakage of the 8tooth/composite interfaces was recorded in millimeters. KHN was measured at both surfaces of cylindrical specimens (Ø=5mm, 1 or 2mm height). ANOVA/Tukey test were used (alpha=0.05). KHN top and bottom were compared using paired t-tests. Stress increased significantly with dose (3J/cm(2): 1.4+/-0.3(c); 6J/cm(2): 4.3+/-0.5(b); 12J/cm(2): 9.3+/-0.6(a); 24J/cm(2): 9.9+/-0.7(a), in MPa). For both average and maximum microleakage, interactions were not statistically significant (p>0.05). Tooth average microleakage was influenced by the adhesive system (SBdirect association between stress and microleakage was suggested with SB, while with PR showed severe dye penetration at all doses evaluated. KHN showed significant differences among all groups, except at bottom of 2mm specimens cured with 3 and 6J/cm(2). Differences between top and bottom were found for 2mm specimens cured with 3 and 6J/cm(2). Stress and microleakage increased significantly with the applied radiant exposure.

  8. Validation of the mean radiant temperature simulated by the RayMan software in urban environments

    Science.gov (United States)

    Lee, Hyunjung; Mayer, Helmut

    2016-11-01

    The RayMan software is worldwide applied in investigations on different issues in human-biometeorology. However, only the simulated mean radiant temperature ( T mrt) has been validated so far in a few case studies. They are based on T mrt values, which were experimentally determined in urban environments by use of a globe thermometer or applying the six-directional method. This study analyses previous T mrt validations in a comparative manner. Their results are extended by a recent validation of T mrt in an urban micro-environment in Freiburg (southwest Germany), which can be regarded as relatively heterogeneous due to different shading intensities by tree crowns. In addition, a validation of the physiologically equivalent temperature (PET) simulated by RayMan is conducted for the first time. The validations are based on experimentally determined T mrt and PET values, which were calculated from measured meteorological variables in the daytime of a clear-sky summer day. In total, the validation results show that RayMan is capable of simulating T mrt satisfactorily under relatively homogeneous site conditions. However, the inaccuracy of simulated T mrt is increasing with lower sun elevation and growing heterogeneity of the simulation site. As T mrt represents the meteorological variable that mostly governs PET in the daytime of clear-sky summer days, the accuracy of simulated T mrt is mainly responsible for the accuracy of simulated PET. The T mrt validations result in some recommendations, which concern an update of physical principles applied in the RayMan software to simulate the short- and long-wave radiant flux densities, especially from vertical building walls and tree crowns.

  9. Vocal Ergonomics in the Workplace: Heating, Ventilation, and Air-Conditioning Method Influences on Vocal Comfort and Function

    Science.gov (United States)

    Sandage, Mary J.; Rahn, Keith A.; Smith, Audrey G.

    2017-01-01

    Purpose: The purpose of this study was to examine the influence of the heating, ventilation, and air-conditioning method on voice function following a voicing task using ecologically valid offices, one with radiant HVAC and one with forced air. Method: A total of 12 consented participants (6 women, 6 men) narrated a video in each of 4…

  10. Net neutrality and the value chain for video

    NARCIS (Netherlands)

    Nooren, P.A.; Leurdijk, A.; Eijk, N. van

    2012-01-01

    Purpose: Video distribution over the internet leads to heated net-neutrality related debates between network operators and over-the-top application providers. The purpose of this paper is to analyze this debate from a new perspective that takes into account all of the assets that companies try to

  11. Molecular heat pump.

    Science.gov (United States)

    Segal, Dvira; Nitzan, Abraham

    2006-02-01

    We propose a molecular device that pumps heat against a thermal gradient. The system consists of a molecular element connecting two thermal reservoirs that are characterized by different spectral properties. The pumping action is achieved by applying an external force that periodically modulates molecular levels. This modulation affects periodic oscillations of the internal temperature of the molecule and the strength of its coupling to each reservoir resulting in a net heat flow in the desired direction. The heat flow is examined in the slow and fast modulation limits and for different modulation wave forms, thus making it possible to optimize the device performance.

  12. Linear Logic on Petri Nets

    DEFF Research Database (Denmark)

    Engberg, Uffe Henrik; Winskel, Glynn

    This article shows how individual Petri nets form models of Girard's intuitionistic linear logic. It explores questions of expressiveness and completeness of linear logic with respect to this interpretation. An aim is to use Petri nets to give an understanding of linear logic and give some apprai...

  13. Reference Guide Microsoft.NET

    NARCIS (Netherlands)

    Zee M van der; Verspaij GJ; Rosbergen S; IMP; NMD

    2003-01-01

    Developers, administrators and managers can get more understanding of the .NET technology with this report. They can also make better choices how to use this technology. The report describes the results and conclusions of a study of the usability for the RIVM of this new generation .NET development

  14. Net neutrality and audiovisual services

    NARCIS (Netherlands)

    van Eijk, N.; Nikoltchev, S.

    2011-01-01

    Net neutrality is high on the European agenda. New regulations for the communication sector provide a legal framework for net neutrality and need to be implemented on both a European and a national level. The key element is not just about blocking or slowing down traffic across communication

  15. A Small Universal Petri Net

    Directory of Open Access Journals (Sweden)

    Dmitry A. Zaitsev

    2013-09-01

    Full Text Available A universal deterministic inhibitor Petri net with 14 places, 29 transitions and 138 arcs was constructed via simulation of Neary and Woods' weakly universal Turing machine with 2 states and 4 symbols; the total time complexity is exponential in the running time of their weak machine. To simulate the blank words of the weakly universal Turing machine, a couple of dedicated transitions insert their codes when reaching edges of the working zone. To complete a chain of a given Petri net encoding to be executed by the universal Petri net, a translation of a bi-tag system into a Turing machine was constructed. The constructed Petri net is universal in the standard sense; a weaker form of universality for Petri nets was not introduced in this work.

  16. GAM-HEAT -- a computer code to compute heat transfer in complex enclosures. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.E.; Taylor, J.R.; Kielpinski, A.L.; Steimke, J.L.

    1991-02-01

    The GAM-HEAT code was developed for heat transfer analyses associated with postulated Double Ended Guillotine Break Loss Of Coolant Accidents (DEGB LOCA) resulting in a drained reactor vessel. In these analyses the gamma radiation resulting from fission product decay constitutes the primary source of energy as a function of time. This energy is deposited into the various reactor components and is re- radiated as thermal energy. The code accounts for all radiant heat exchanges within and leaving the reactor enclosure. The SRS reactors constitute complex radiant exchange enclosures since there are many assemblies of various types within the primary enclosure and most of the assemblies themselves constitute enclosures. GAM-HEAT accounts for this complexity by processing externally generated view factors and connectivity matrices, and also accounts for convective, conductive, and advective heat exchanges. The code is applicable for many situations involving heat exchange between surfaces within a radiatively passive medium. The GAM-HEAT code has been exercised extensively for computing transient temperatures in SRS reactors with specific charges and control components. Results from these computations have been used to establish the need for and to evaluate hardware modifications designed to mitigate results of postulated accident scenarios, and to assist in the specification of safe reactor operating power limits. The code utilizes temperature dependence on material properties. The efficiency of the code has been enhanced by the use of an iterative equation solver. Verification of the code to date consists of comparisons with parallel efforts at Los Alamos National Laboratory and with similar efforts at Westinghouse Science and Technology Center in Pittsburgh, PA, and benchmarked using problems with known analytical or iterated solutions. All comparisons and tests yield results that indicate the GAM-HEAT code performs as intended.

  17. Alongshore wind stress and heat flux divergence off Visakhapatnam, east coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Sadhuram, Y.; Rao, B.P.; Rao, D.P.

    Annual variation of heat flux divergence (Qv) was computed for the coastal waters of Visakhapatnam. The mean values of net heat exchange (Qn) and heat flux divergence (Qv) were found to be 114 and 115 W.m/2 respectively on annual scale. The net heat...

  18. C-fiber-related EEG-oscillations induced by laser radiant heat stimulation of capsaicin-treated skin

    Directory of Open Access Journals (Sweden)

    Claudia Domnick

    2009-03-01

    Full Text Available Claudia Domnick1, Michael Hauck1,2,3, Kenneth L Casey3, Andreas K Engel1, Jürgen Lorenz1,3,41Department of Neurophysiology and Pathophysiology; 2Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; 3Department of Neurology, University of Michigan, Ann Arbor, MI, USA; 4Faculty of Life Sciences, Hamburg University of Applied Sciences, Hamburg, GermanyAbstract: Nociceptive input reaches the brain via two different types of nerve fibers, moderately fast A-delta and slowly conducting C-fibers, respectively. To explore their distinct roles in normal and inflammatory pain we used laser stimulation of normal and capsaicin treated skin at proximal and distal arm sites in combination with time frequency transformation of electroencephalography (EEG data. Comparison of phase-locked (evoked and non-phase-locked (total EEG to laser stimuli revealed three significant pain-related oscillatory responses. First, an evoked response in the delta-theta band, mediated by A-fibers, was reduced by topical capsaicin treatment. Second, a decrease of total power in the alpha-to-gamma band reflected both an A- and C-nociceptor-mediated response with only the latter being reduced by capsaicin treatment. Finally, an enhancement of total power in the upper beta band was mediated exclusively by C-nociceptors and appeared strongly augmented by capsaicin treatment. These findings suggest that phase-locking of brain activity to stimulus onset is a critical feature of A-delta nociceptive input, allowing rapid orientation to salient and potentially threatening events. In contrast, the subsequent C-nociceptive input exhibits clearly less phase coupling to the stimulus. It may primarily signal the tissue status allowing more long-term behavioral adaptations during ongoing inflammatory events that accompany tissue damage.Keywords: C-fibers, oscillations, EEG, laser, capsaicin, inflammatory pain

  19. Numerical investigation of the single scattering albedo of radiant energy passing through polydisperse crystalline media

    Science.gov (United States)

    Shefer, O. V.; Shefer, V. A.; Sinyukova, E. A.

    2014-12-01

    Studies of the role of atmospheric formations and cosmic dust clouds in the transmission of radiation is one of the most uncertain and difficult problems in astrophysics and climatology. One of the main tasks of practical astrophysics is the interpretation of the results of observations of space objects. There is a necessity of describing the propagation of electromagnetic waves in the environment. In this paper, applying the numerical methods, we study the optical characteristics of polydisperse media consisting of randomly oriented and preferentially oriented crystals, taking into account the distribution function of particle sizes. Particles of spherical shape and ensembles preferentially oriented plate crystals are considered as models. Mie theory and method of physical optics are used to calculate the scattering characteristics. Numerical study of the effects of extinction, scattering and absorption on the single scattering albedo of radiation allowed us to establish the basic patterns of the passage of radiant energy through a translucent medium. At the visible range of wavelengths, both for small and large particles, the single scattering albedo is almost equal to 1. The spectral course of this optical performance is mainly determined by the refractive index of the particles. Features of wave dependence of single scattering albedo are associated with microphysical parameters of the environment, which are more pronounced when the attenuation of the radiation is determined mainly by the scattering. Higher values of the absorption index and optical thickness of the crystal reduce the value of the single scattering albedo, smoothing the features of its spectral course. Values of the absorption index of substance, as value of the order of 0.1, do not lead to a decrease of the single scattering albedo as it is less than 0.5. This allows us to conclude that we should not neglect the microphysical characteristics of the crystals even by strong absorption of radiant

  20. High-level Petri Nets

    DEFF Research Database (Denmark)

    High-level Petri nets are now widely used in both theoretical analysis and practical modelling of concurrent systems. The main reason for the success of this class of net models is that they make it possible to obtain much more succinct and manageable descriptions than can be obtained by means...... of low-level Petri nets - while, on the other hand, they still offer a wide range of analysis methods and tools. The step from low-level nets to high-level nets can be compared to the step from assembly languages to modern programming languages with an elaborated type concept. In low-level nets...... there is only one kind of token and this means that the state of a place is described by an integer (and in many cases even by a boolean). In high-level nets each token can carry a complex information/data - which, e.g., may describe the entire state of a process or a data base. Today most practical...

  1. The effects of radiant cooling versus convective cooling on human eye tear film stability and blinking rate

    DEFF Research Database (Denmark)

    Nygaard, Linette; Uth, Simon C.; Bolashikov, Zhecho Dimitrov

    2014-01-01

    The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation. The subj......The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation....... The subjects participated in four two-hour experiments. The room air temperature was kept at 26 °C or 28 °C. Tear film samples were collected after 30 min of acclimatisation and at the end of the exposures. Eye blinking frequency was analysed for the first and last 15 min of each exposure. The tear film...

  2. Heat index and adjusted temperature as surrogates for wet bulb globe temperature to screen for occupational heat stress.

    Science.gov (United States)

    Bernard, Thomas E; Iheanacho, Ivory

    2015-01-01

    Ambient temperature and relative humidity are readily ava-ilable and thus tempting metrics for heat stress assessment. Two methods of using air temperature and relative humidity to create an index are Heat Index and Adjusted Temperature. The purposes of this article are: (1) to examine how well Heat Index and Adjusted Temperature estimated the wet bulb globe temperature (WBGT) index, and (2) to suggest how Heat Index and Adjusted Temperature can be used to screen for heat stress level. Psychrometric relationships were used to estimate values of actual WBGT for conditions of air temperature, relative humidity, and radiant heat at an air speed of 0.5 m/s. A relationship between Heat Index [°F] and WBGT [°C] was described by WBGT = -0.0034 HI(2) + 0.96 HI - 34. At lower Heat Index values, the equation estimated WBGTs that were ± 2 °C-WBGT around the actual value, and to about ± 0.5 °C-WBGT for Heat Index values > 100 °F. A relationship between Adjusted Temperature [°F] and WBGT [°C] was described by WBGT = 0.45 Tadj - 16. The actual WBGT was between 1 °C-WBGT below the estimated value and 1.4 °C-WBGT above. That is, there was a slight bias toward overestimating WBGT from Adjusted Temperature. Heat stress screening tables were constructed for metabolic rates of 180, 300, and 450 W. The screening decisions were divided into four categories: (1) exposure limit at rest. The authors do not recommend using Heat Index or Adjusted Temperature instead of WBGT, but they may be used to screen for circumstances when a more detailed analysis using WBGT is appropriate. A particular weakness is accounting for radiant heat; and neither air speed nor clothing was considered.

  3. Pro asynchronous programming with .NET

    CERN Document Server

    Blewett, Richard; Ltd, Rock Solid Knowledge

    2014-01-01

    Pro Asynchronous Programming with .NET teaches the essential skill of asynchronous programming in .NET. It answers critical questions in .NET application development, such as: how do I keep my program responding at all times to keep my users happy how do I make the most of the available hardware how can I improve performanceIn the modern world, users expect more and more from their applications and devices, and multi-core hardware has the potential to provide it. But it takes carefully crafted code to turn that potential into responsive, scalable applications.With Pro Asynchronous Programming

  4. Conformal Nets II: Conformal Blocks

    Science.gov (United States)

    Bartels, Arthur; Douglas, Christopher L.; Henriques, André

    2017-08-01

    Conformal nets provide a mathematical formalism for conformal field theory. Associated to a conformal net with finite index, we give a construction of the `bundle of conformal blocks', a representation of the mapping class groupoid of closed topological surfaces into the category of finite-dimensional projective Hilbert spaces. We also construct infinite-dimensional spaces of conformal blocks for topological surfaces with smooth boundary. We prove that the conformal blocks satisfy a factorization formula for gluing surfaces along circles, and an analogous formula for gluing surfaces along intervals. We use this interval factorization property to give a new proof of the modularity of the category of representations of a conformal net.

  5. Experimental research on the indoor temperature and humidity fields in radiant ceiling air-conditioning system under natural ventilation

    Science.gov (United States)

    Huang, Tao; Xiang, Yutong; Wang, Yonghong

    2017-05-01

    In this paper, the indoor temperature and humidity fields of the air in a metal ceiling radiant panel air conditioning system with fresh air under natural ventilation were researched. The temperature and humidity distributions at different height and different position were compared. Through the computation analysis of partial pressure of water vapor, the self-recovery characteristics of humidity after the natural ventilation was discussed.

  6. PAIR INFLUENCE OF WIND SPEED AND MEAN RADIANT TEMPERATURE ON OUTDOOR THERMAL COMFORT OF HUMID TROPICAL ENVIRONMENT

    OpenAIRE

    Sangkertadi Sangkertadi; Reny Syafriny

    2016-01-01

    The purposes of this article is to explore knowledge of outdoor thermal comfort in humid tropical environment for urban activities especially for people in walking activity, and those who stationary/seated with moderate action. It will be characterized the pair influence of wind speed and radiant temperature on the outdoor thermal comfort. Many of researchers stated that those two microclimate variables give significant role on outdoor thermal comfort in tropical humid area. Outdoor Tropical ...

  7. Assessing the accuracy of globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate

    Science.gov (United States)

    Khrit, N. G.; Alghoul, M. A.; Sopian, K.; Lahimer, A. A.; Elayeb, O. K.

    2017-11-01

    Assessing outdoor human thermal comfort and urban climate quality require experimental investigation of microclimatic conditions and their variations in open urban spaces. For this, it is essential to provide quantitative information on air temperature, humidity, wind velocity and mean radiant temperature. These parameters can be quantified directly except mean radiant temperature (Tmrt). The most accurate method to quantify Tmrt is integral radiation measurements (3-D shortwave and long-wave) which require using expensive radiometer instruments. To overcome this limitation the well-known globe thermometer method was suggested to calculate Tmrt. The aim of this study was to assess the possibility of using indoor globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate. Globe thermometer method using small and large sizes of black-painted copper globes (50mm, 150mm) were used to estimate Tmrt and compare it with the reference Tmrt estimated by integral radiation method. The results revealed that the globe thermometer method considerably overestimated Tmrt during the middle of the day and slightly underestimated it in the morning and late evening. The difference between the two methods was obvious when the amount of incoming solar radiation was high. The results also showed that the effect of globe size on the estimated Tmrt is mostly small. Though, the estimated Tmrt by the small globe showed a relatively large amount of scattering caused by rapid changes in radiation and wind speed.

  8. Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements

    Directory of Open Access Journals (Sweden)

    Adriano Fonseca Lima

    2016-11-01

    Full Text Available Objectives In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs on the degree of conversion (DC and the mechanical properties of resin cements. Materials and Methods Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG, according to the different radiant exposures (5, 10, and 20 J/cm2 and two LCUs (single-peak and polywave. The specimens were made (7 mm in length × 2 mm in width × 1 mm in height using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA and post hoc Tukey's test were performed. Results No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

  9. PAIR INFLUENCE OF WIND SPEED AND MEAN RADIANT TEMPERATURE ON OUTDOOR THERMAL COMFORT OF HUMID TROPICAL ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Sangkertadi Sangkertadi

    2016-01-01

    Full Text Available The purposes of this article is to explore knowledge of outdoor thermal comfort in humid tropical environment for urban activities especially for people in walking activity, and those who stationary/seated with moderate action. It will be characterized the pair influence of wind speed and radiant temperature on the outdoor thermal comfort. Many of researchers stated that those two microclimate variables give significant role on outdoor thermal comfort in tropical humid area. Outdoor Tropical Comfort (OTC model was used for simulation in this study. The model output is comfort scale that refers on ASHRAE definition. The model consists of two regression equations with variables of air temperature, globe temperature, wind speed, humidity and body posture, for two types of activity: walking and seated. From the results it can be stated that there is significant role of wind speed to reduce mean radiant temperature and globe temperature, when the velocity is elevated from 0.5 m/s to 2 m/s. However, the wind has not play significant role when the speed is changed from 2 m/s to 3.5 m/s. The results of the study may inspire us to implement effectiveness of electrical-fan equipment for outdoor space in order to get optimum wind speed, coupled with optimum design of shading devices to minimize radiant temperature for thermal comfort.

  10. General Relativistic Radiant Shock Waves in the Post-Quasistatic Approximation

    Energy Technology Data Exchange (ETDEWEB)

    H, Jorge A Rueda [Centro de Fisica Fundamental, Universidad de Los Andes, Merida 5101, Venezuela Escuela de Fisica, Universidad Industrial de Santander, A.A. 678, Bucaramanga (Colombia); Nunez, L A [Centro de Fisica Fundamental, Universidad de Los Andes, Merida 5101, Venezuela Centro Nacional de Calculo Cientifico, Universidad de Los Andes, CeCalCULA, Corporacion Parque Tecnologico de Merida, Merida 5101, Venezuela (Venezuela)

    2007-05-15

    An evolution of radiant shock wave front is considered in the framework of a recently presented method to study self-gravitating relativistic spheres, whose rationale becomes intelligible and finds full justification within the context of a suitable definition of the post-quasistatic approximation. The spherical matter configuration is divided into two regions by the shock and each side of the interface having a different equation of state and anisotropic phase. In order to simulate dissipation effects due to the transfer of photons and/or neutrinos within the matter configuration, we introduce the flux factor, the variable Eddington factor and a closure relation between them. As we expected the strong of the shock increases the speed of the fluid to relativistic ones and for some critical values is larger than light speed. In addition, we find that energy conditions are very sensible to the anisotropy, specially the strong energy condition. As a special feature of the model, we find that the contribution of the matter and radiation to the radial pressure are the same order of magnitude as in the mant as in the core, moreover, in the core radiation pressure is larger than matter pressure.

  11. Petri Net Tool Overview 1986

    DEFF Research Database (Denmark)

    Jensen, Kurt; Feldbrugge, Frits

    1987-01-01

    This paper provides an overview of the characteristics of all currently available net based tools. It is a compilation of information provided by tool authors or contact persons. A concise one page overview is provided as well....

  12. Understanding Net Zero Energy Buildings

    DEFF Research Database (Denmark)

    Salom, Jaume; Widén, Joakim; Candanedo, José

    2011-01-01

    Although several alternative definitions exist, a Net-Zero Energy Building (Net ZEB) can be succinctly described as a grid-connected building that generates as much energy as it uses over a year. The “net-zero” balance is attained by applying energy conservation and efficiency measures...... and by incorporating renewable energy systems. While based on annual balances, a complete description of a Net ZEB requires examining the system at smaller time-scales. This assessment should address: (a) the relationship between power generation and building loads and (b) the resulting interaction with the power grid....... This paper presents and categorizes quantitative indicators suitable to describe both aspects of the building’s performance. These indicators, named LMGI - Load Matching and Grid Interaction indicators, are easily quantifiable and could complement the output variables of existing building simulation tools...

  13. PolicyNet Publication System

    Data.gov (United States)

    Social Security Administration — The PolicyNet Publication System project will merge the Oracle-based Policy Repository (POMS) and the SQL-Server CAMP system (MSOM) into a new system with an Oracle...

  14. KM3NeT

    CERN Multimedia

    KM3NeT is a large scale next-generation neutrino telescope located in the deep waters of the Mediterranean Sea, optimized for the discovery of galactic neutrino sources emitting in the TeV energy region.

  15. Net Neutrality: Background and Issues

    National Research Council Canada - National Science Library

    Gilroy, Angele A

    2006-01-01

    .... The move to place restrictions on the owners of the networks that compose and provide access to the Internet, to ensure equal access and nondiscriminatory treatment, is referred to as "net neutrality...

  16. Petri Nets in Cryptographic Protocols

    DEFF Research Database (Denmark)

    Crazzolara, Federico; Winskel, Glynn

    2001-01-01

    A process language for security protocols is presented together with a semantics in terms of sets of events. The denotation of process is a set of events, and as each event specifies a set of pre and postconditions, this denotation can be viewed as a Petri net. By means of an example we illustrate...... how the Petri-net semantics can be used to prove security properties....

  17. The Economics of Net Neutrality

    OpenAIRE

    Hahn, Robert W.; Wallsten, Scott

    2006-01-01

    This essay examines the economics of "net neutrality" and broadband Internet access. We argue that mandating net neutrality would be likely to reduce economic welfare. Instead, the government should focus on creating competition in the broadband market by liberalizing more spectrum and reducing entry barriers created by certain local regulations. In cases where a broadband provider can exercise market power the government should use its antitrust enforcement authority to police anticompetitiv...

  18. Low Temperature Heating and High Temperature Cooling in Buildings

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk

    , a single-family house designed for plus-energy targets and equipped with a radiant water-based floor heating and cooling system was studied by means of full-scale measurements, dynamic building simulations and thermodynamic evaluation tools. Thermal indoor environment and energy performance of the house......A heating and cooling system could be divided into three parts: terminal units (emission system), distribution system, and heating and cooling plant (generation system). The choice of terminal unit directly affects the energy performance, and the indoor environment in that space. Therefore......, a holistic system evaluation is necessary to ensure an optimal indoor environment for the occupants and to achieve energy efficiency simultaneously. Low temperature heating and high temperature cooling systems are one of the possible approaches to heat or cool indoor spaces in buildings. In this thesis...

  19. Importance of 3-D radiant flux densities for outdoor human thermal comfort on clear-sky summer days in Freiburg, Southwest Germany

    Directory of Open Access Journals (Sweden)

    Hyunjung Lee

    2014-09-01

    Full Text Available This study concerns the role of short- and long-wave radiant flux densities from different directions in complex urban settings for human thermal comfort on clear-sky summer days. The aims of the investigation are to quantify the importance of the sky view factor as an urban design-dependent variable for the 3-D radiant flux densities absorbed by the standardized human-biometeorological reference person and to analyze the varying impact of the absorbed 3-D short- and long-wave radiant flux densities on the mean radiant temperature (Tmrt$T_{\\text{mrt}}$, near-surface air temperature (Ta$T_{\\text{a}}$ and physiologically equivalent temperature (PET.The results obtained by measuring campaigns and numerical simulations point to the different importance of the absorbed 3-D radiant flux densities for human thermal comfort characterized by Ta$T_{\\text{a}}$, Tmrt$T_{\\text{mrt}}$ and PET. The magnitude of Tmrt$T_{\\text{mrt}}$ is mainly determined by the total of the absorbed 3-D long-wave radiant flux densities. However, the fluctuations of Tmrt$T_{\\text{mrt}}$ are mainly governed by the total of the absorbed 3-D short-wave radiant flux densities. Their variance can be well explained by the variance of the sky view factor related to the southern part of the upper half space. Taking account of the different impact of the 3-D radiant flux densities, Tmrt$T_{\\text{mrt}}$ can be quite well estimated by a multiple regression using the total of the absorbed 3-D short-wave radiant flux densities and the absorbed long-wave radiant flux density from the lower half space as independent variables. PET can be well estimated by a multiple regression showing Tmrt$T_{\\text{mrt}}$ and Ta$T_{\\text{a}}$ as independent variables. On a hot summer day, the increase of the albedo of vertical building walls within a simple E-W oriented street canyon leads to a decrease of the surface temperature of the S-facing wall, but to an increase of Tmrt$T_{\\text{mrt}}$ and PET

  20. 26 CFR 1.904(f)-3 - Allocation of net operating losses and net capital losses.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Allocation of net operating losses and net....904(f)-3 Allocation of net operating losses and net capital losses. For rules relating to the allocation of net operating losses and net capital losses, see § 1.904(g)-3T. ...

  1. 29 CFR 4204.13 - Net income and net tangible assets tests.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Net income and net tangible assets tests. 4204.13 Section....13 Net income and net tangible assets tests. (a) General. The criteria under this section are that either— (1) Net income test. The purchaser's average net income after taxes for its three most recent...

  2. QCD phase diagram : heating or compressing ?

    CERN Multimedia

    Maire, Antonin

    2011-01-01

    The sketch tries to address the question of the difference between heating and compressing the baryonic matter in relativistic heavy-ion collisions, i.e. how one can reach in the laboratory "high" temperature at "low" net baryon density (baryon chemical potential) or "low" temperature at "high" net baryon density.

  3. Net-Zero Energy Technical Shelter

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per; Jensen, Rasmus Lund

    2014-01-01

    Technical shelters are the basic structures for storing electronic and technical equipment, and commonly used for telecommunication base station, windmill, gas station, etc. Due to their high internal heat load density and special operation schedule, they consume more energy than normal residential...... or commercial buildings. On the other hand, it is a big challenge to power the technical shelter in remote area where the grids are either not available or the expansion of grid is expensive. In order to minimize the energy consumption and obtain a reliable and cost-efficient power solution for technical...... shelter, this study will apply the net-zero energy concept into the technical shelter design. The energy conservation can be achieved by proper design of building envelop and optimization of the cooling strategies. Both experiments and numerical simulations are carried out to investigate the indoor...

  4. Effects of Channel Geometry and Coolant Fluid on Thermoelectric Net Power

    DEFF Research Database (Denmark)

    Rezaniakolaei, Alireza; Rosendahl, Lasse; Sørensen, Kim

    2014-01-01

    generation in TEG for different size of hydraulic diameter of plate-fin heat sink and over a wide range of Reynolds number. The particular focus of this study is to find optimal Reynolds number in each considered channel hydraulic diameter and to explore optimal channel hydraulic diameter for maximum TEG net......, and the maximum net power output occurs at smaller Reynolds number when the channel hydraulic diameter reduces.......Channel geometry has a strong influence on the heat transfer coefficient and cooling energy input in a heat sink. The net power output in a thermoelectric generator (TEG) can be defined as power generation minus the required cooling energy in TEG. This study aims to evaluate the net power...

  5. Nonadiabatic electron heat pump

    OpenAIRE

    Rey, Miguel; Strass, Michael; Kohler, Sigmund; Hänggi, Peter; Sols, Fernando

    2006-01-01

    We investigate a mechanism for extracting heat from metallic conductors based on the energy-selective transmission of electrons through a spatially asymmetric resonant structure subject to ac driving. This quantum refrigerator can operate at zero net electronic current as it replaces hot by cold electrons through two energetically symmetric inelastic channels. We present numerical results for a specific heterostructure and discuss general trends. We also explore the conditions under which the...

  6. Quantum heat engine with continuum working medium

    OpenAIRE

    Li, S.; Wang, H.; Sun, Y. D.; Yi, X. X.

    2006-01-01

    We introduce a new quantum heat engine, in which the working medium is a quantum system with a discrete level and a continuum. Net work done by this engine is calculated and discussed. The results show that this quantum heat engine behaves like the two-level quantum heat engine in both the high-temperature and the low-temperature limits, but it operates differently in temperatures between them. The efficiency of this quantum heat engine is also presented and discussed.

  7. An inverse radiation problem of estimating heat-transfer coefficient in participating media

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.M.; Lee, W.J. [Sogang University, Seoul (Republic of Korea). Dept. of Chemical Engineering

    2002-06-01

    In the radiant cooler, where the hot gas from the pulverized coal gasifier or combustor is cooled to generate steam, the wall heat-transfer coefficient varies due to ash deposition. The authors investigated an inverse radiation problem of estimating the heat-transfer coefficient from temperature measurement in the radiant cooler. The inverse radiation problem is solved through the minimization of a performance function, which is expressed by the sum of square residuals between calculated and observed temperature, utilizing the conjugate gradient method. The gradient of the performance function is evaluated by means of the improved adjoint variable method, which resolves the difficulty associated with the singularity of the adjoint equation through its inherent regularization property. The effects of the number of measurement points and measurement noise on the accuracy of estimation are also investigated.

  8. The total spectral radiant flux calibration using a spherical spectrometer at National Institute of Metrology China

    Science.gov (United States)

    Zhao, Weiqiang; Liu, Hui; Liu, Jian

    2016-11-01

    At present day, in the field of lighting the incandescent lamps are phasing out. The solid state lighting products, i.e. LED, and the related market are developing very fast in China for its promising application, due to the energy-saving and the colorful features. For the quality control and the commercial trade purpose, it is highly necessary to measure the optical parameters of LED light sources with a fast, easy and affordable facility. Therefore, more test labs use the spherical spectrometer to measure LED. The quasi- monochrome of LED and the V(lambda) of silicon photodetector mismatch problem is reduced or avoided, because the total spectral radiant flux (TSRF) is measured, and all the optical parameters are calculate from the TSRF. In such a way, the spherical spectrometer calibration requires TSRF standard lamps instead of the traditional total flux standard lamps. National Institute of Metrology China (NIM) has studied and developed the facilities for TSRF measurement and provides related calibration services. This paper shows the TSRF standard lamp calibration procedure using a spherical spectrometer in every-day calibration and its traceable link to the primary SI unit at NIM. The sphere is of 1.5 m diameter, and installed with a spectrometer and a silicon photodetector. It also shows the detail of data process, such as the spectral absorption correction method and the calculation of the result derived from the spectral readings. The TSRF calibration covers the spectra range of 350 nm to 1050 nm, with a measurement uncertainty of 3.6% 1.8% (k=2).

  9. Highly Controlled Synthesis and Super-Radiant Photoluminescence of Plasmonic Cube-in-Cube Nanoparticles.

    Science.gov (United States)

    Park, Jeong-Eun; Kim, Sungi; Son, Jiwoong; Lee, Yeonhee; Nam, Jwa-Min

    2016-12-14

    The plasmonic properties of metal nanostructures have been heavily utilized for surface-enhanced Raman scattering (SERS) and metal-enhanced fluorescence (MEF), but the direct photoluminescence (PL) from plasmonic metal nanostructures, especially with plasmonic coupling, has not been widely used as much as SERS and MEF due to the lack of understanding of the PL mechanism, relatively weak signals, and the poor availability of the synthetic methods for the nanostructures with strong PL signals. The direct PL from metal nanostructures is beneficial if these issues can be addressed because it does not exhibit photoblinking or photobleaching, does not require dye-labeling, and can be employed as a highly reliable optical signal that directly depends on nanostructure morphology. Herein, we designed and synthesized plasmonic cube-in-cube (CiC) nanoparticles (NPs) with a controllable interior nanogap in a high yield from Au nanocubes (AuNCs). In synthesizing the CiC NPs, we developed a galvanic void formation (GVF) process, composed of replacement/reduction and void formation steps. We unraveled the super-radiant character of the plasmonic coupling-induced plasmon mode which can result in highly enhanced PL intensity and long-lasting PL, and the PL mechanisms of these structures were analyzed and matched with the plasmon hybridization model. Importantly, the PL intensity and quantum yield (QY) of CiC NPs are 31 times and 16 times higher than those of AuNCs, respectively, which have shown the highest PL intensity and QY reported for metallic nanostructures. Finally, we confirmed the long-term photostability of the PL signal, and the signal remained stable for at least 1 h under continuous illumination.

  10. Electron heat flux instability

    Science.gov (United States)

    Saeed, Sundas; Sarfraz, M.; Yoon, P. H.; Lazar, M.; Qureshi, M. N. S.

    2017-02-01

    The heat flux instability is an electromagnetic mode excited by a relative drift between the protons and two-component core-halo electrons. The most prominent application may be in association with the solar wind where drifting electron velocity distributions are observed. The heat flux instability is somewhat analogous to the electrostatic Buneman or ion-acoustic instability driven by the net drift between the protons and bulk electrons, except that the heat flux instability operates in magnetized plasmas and possesses transverse electromagnetic polarization. The heat flux instability is also distinct from the electrostatic counterpart in that it requires two electron species with relative drifts with each other. In the literature, the heat flux instability is often called the 'whistler' heat flux instability, but it is actually polarized in the opposite sense to the whistler wave. This paper elucidates all of these fundamental plasma physical properties associated with the heat flux instability starting from a simple model, and gradually building up more complexity towards a solar wind-like distribution functions. It is found that the essential properties of the instability are already present in the cold counter-streaming electron model, and that the instability is absent if the protons are ignored. These instability characteristics are highly reminiscent of the electron firehose instability driven by excessive parallel temperature anisotropy, propagating in parallel direction with respect to the ambient magnetic field, except that the free energy source for the heat flux instability resides in the effective parallel pressure provided by the counter-streaming electrons.

  11. Study of heat exposure in the work environment in Jeddah.

    Science.gov (United States)

    Noweir, M H; Moreb, A A; Bafail, A O

    1996-05-01

    The present work was conducted to define the magnitude of the problem of heat exposure in Jeddah and the role of both the climatic and the industrial factors on the total heat load. Indoor heat exposure was studied in an industrial complex of 5 plants for cables' manufacturing. Outdoor heat exposure was studied in shaded and unshaded operations in Jeddah Islamic Port (JIP). The heat exposure parameters, including air temperature (Ta), wet bulb temperature (Tw), and globe temperature (Tg), as well as the wet bulb globe temperature (WBGT) heat stress index, the relative humidity and the air velocity, were assessed at representative locations. Results of the study indicated that: (a) the levels of heat exposure exceeded the TLV in mostly all the work areas where no air-conditioning is provided. (b) the ambient heat is the factor contributing most to the heat load both in summer and in winter. (c) the radiant heat from furnaces and hot metal rolling and milling adds more heat load to the work environment in specific operations. An outline of a control strategy has been suggested, emphasizing evaporative engineering heat control, work and hygienic practices and auxiliary cooling clothing.

  12. TimeNET Optimization Environment

    Directory of Open Access Journals (Sweden)

    Christoph Bodenstein

    2015-12-01

    Full Text Available In this paper a novel tool for simulation-based optimization and design-space exploration of Stochastic Colored Petri nets (SCPN is introduced. The working title of this tool is TimeNET Optimization Environment (TOE. Targeted users of this tool are people modeling complex systems with SCPNs in TimeNET who want to find parameter sets that are optimal for a certain performance measure (fitness function. It allows users to create and simulate sets of SCPNs and to run different optimization algorithms based on parameter variation. The development of this tool was motivated by the need to automate and speed up tests of heuristic optimization algorithms to be applied for SCPN optimization. A result caching mechanism is used to avoid recalculations.

  13. Heat Islands

    Science.gov (United States)

    EPA's Heat Island Effect Site provides information on heat islands, their impacts, mitigation strategies, related research, a directory of heat island reduction initiatives in U.S. communities, and EPA's Heat Island Reduction Program.

  14. Heat Waves

    Science.gov (United States)

    Heat Waves Dangers we face during periods of very high temperatures include: Heat cramps: These are muscular pains and ... having trouble with the heat. If a heat wave is predicted or happening… - Slow down. Avoid strenuous ...

  15. Experimental and numerical simulation analysis of heat transfer on a closed enclosure

    Directory of Open Access Journals (Sweden)

    A. A. Minea

    2012-04-01

    Full Text Available The main objective of this work was to evaluate the behavior of an oval heated closed enclosure, when variable radiant panels were introduced. The experimental investigation showed that their efficiency was depending on their position. An experimental investigation, as well as numerical simulation was carried out. Totally, 24 test runs were performed from which the maximal heating temperature was measured. The experimental findings were also compared to the simulation results and a reasonable agreement was observed. Finally, based on the results of this study, a correlation was developed to predict the inner configuration for heat transfer enhancement of an oval furnace.

  16. Implementing NetScaler VPX

    CERN Document Server

    Sandbu, Marius

    2014-01-01

    An easy-to-follow guide with detailed step-by step-instructions on how to implement the different key components in NetScaler, with real-world examples and sample scenarios.If you are a Citrix or network administrator who needs to implement NetScaler in your virtual environment to gain an insight on its functionality, this book is ideal for you. A basic understanding of networking and familiarity with some of the different Citrix products such as XenApp or XenDesktop is a prerequisite.

  17. Net4Care PHMR Library

    DEFF Research Database (Denmark)

    2014-01-01

    The Net4Care PHMR library contains a) A GreenCDA approach for constructing a data object representing a PHMR document: SimpleClinicalDocument, and b) A Builder which can produce a XML document representing a valid Danish PHMR (following the MedCom profile) document from the SimpleClinicalDocument......The Net4Care PHMR library contains a) A GreenCDA approach for constructing a data object representing a PHMR document: SimpleClinicalDocument, and b) A Builder which can produce a XML document representing a valid Danish PHMR (following the MedCom profile) document from the Simple...

  18. Pro DLR in NET 4

    CERN Document Server

    Wu, Chaur

    2011-01-01

    Microsoft's Dynamic Language Runtime (DLR) is a platform for running dynamic languages such as Ruby and Python on an equal footing with compiled languages such as C#. Furthermore, the runtime is the foundation for many useful software design and architecture techniques you can apply as you develop your .NET applications. Pro DLR in .NET 4 introduces you to the DLR, showing how you can use it to write software that combines dynamic and static languages, letting you choose the right tool for the job. You will learn the core DLR components such as LINQ expressions, call sites, binders, and dynami

  19. Hierarchies in Coloured Petri Nets

    DEFF Research Database (Denmark)

    Huber, Peter; Jensen, Kurt; Shapiro, Robert M.

    1991-01-01

    The paper shows how to extend Coloured Petri Nets with a hierarchy concept. The paper proposes five different hierarchy constructs, which allow the analyst to structure large CP-nets as a set of interrelated subnets (called pages). The paper discusses the properties of the proposed hierarchy...... constructs, and it illustrates them by means of two examples. The hierarchy constructs can be used for theoretical considerations, but their main use is to describe and analyse large real-world systems. All of the hierarchy constructs are supported by the editing and analysis facilities in the CPN Palette...

  20. Thermoelectric System Absorbing Waste Heat from a Steel Ladle

    Science.gov (United States)

    Lu, Baiyi; Meng, Xiangning; Zhu, Miaoyong; Suzuki, Ryosuke O.

    2018-01-01

    China's iron and steel industry has made great progress in energy savings and emission reductions with the application of many waste heat recovery technologies. However, most of the medium and low temperature waste heat and radiant waste heat has not been effectively utilized. This paper proposes a thermoelectric system that generates electricity by absorbing the radiant heat from the surface of steel ladles in a steel plant. The thermoelectric behavior of modules in this system is analyzed by a numerical simulation method. The effects of external resistance and module structure on thermoelectric performance are also discussed in the temperature range of the wall surface of a steel ladle. The results show that the wall temperature has a significant influence on the thermoelectric behavior of the module, so its uniformity and stability should be considered in practical application. The ratio of the optimum external resistance to the internal resistance of the thermoelectric module is in the range of 1.6-2.0, which indicates the importance of external load optimization for a given thermoelectric system. In addition, the output power and the conversion efficiency of the module can be significantly improved by increasing the length of the thermoelectric legs and adopting a double-layer structure. Finally, through the optimization of external resistance and structure, the power output can reach 83-304 W/m2. This system is shown to be a promising approach for energy recovery.

  1. Potential Use of Radiant Walls to Transfer Energy Between two Building Zones

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per

    2011-01-01

    Due to a reduced energy demand in low energy buildings, low temperature heating and high temperature cooling can be used to control thermal comfort. Nevertheless, highly varying heat loads due to solar radiation can create sometimes an imbalanced energy demand inside the building. Instead of being...

  2. D.NET case study

    International Development Research Centre (IDRC) Digital Library (Canada)

    lremy

    developing products, marketing tools and building capacity of the grass root telecentre workers. D.Net recognized that it had several ideas worth developing into small interventions that would make big differences, but resource constraints were a barrier for scaling-up these initiatives. More demands, limited resources.

  3. Surgery for GEP-NETs

    DEFF Research Database (Denmark)

    Knigge, Ulrich; Hansen, Carsten Palnæs

    2012-01-01

    Surgery is the only treatment that may cure the patient with gastroentero-pancreatic (GEP) neuroendocrine tumours (NET) and neuroendocrine carcinomas (NEC) and should always be considered as first line treatment if R0/R1 resection can be achieved. The surgical and interventional procedures for GEP...

  4. Net Neutrality in the Netherlands

    NARCIS (Netherlands)

    van Eijk, N.

    2014-01-01

    The Netherlands is among the first countries that have put specific net neutrality standards in place. The decision to implement specific regulation was influenced by at least three factors. The first was the prevailing social and academic debate, partly due to developments in the United States. The

  5. Complexity Metrics for Workflow Nets

    DEFF Research Database (Denmark)

    Lassen, Kristian Bisgaard; van der Aalst, Wil M.P.

    2009-01-01

    Process modeling languages such as EPCs, BPMN, flow charts, UML activity diagrams, Petri nets, etc.\\ are used to model business processes and to configure process-aware information systems. It is known that users have problems understanding these diagrams. In fact, even process engineers and system...

  6. A comparison of micro-structured flat-plate and cross-cut heat sinks for thermoelectric generation application

    DEFF Research Database (Denmark)

    Rezania, Alireza; Rosendahl, L. A.

    2015-01-01

    Heat sink configuration has strong impact on net power output from thermoelectric generators (TEGs). A weak cooling strategy can even cause negative net power output from the thermoelectric device. However, the net power output can be significantly improved by optimal design of the heat sink....... In this study, a micro-structured plate-fin heat sink is compared to a modified design of cross-cut heat sink applied to TEGs over a range of temperatures and thermal conductivities. The particular focus of this study is to explore the net power output from the TEG module. The three-dimensional governing......-fin heat sink is higher, while the TEG with cross-cut heat sink has higher maximum net power output at high flow inlet velocity. The maximum net power output is equal in the TEGs with plate-fin heat sink and cross-cut heat sink....

  7. Caught in the Net: Perineuronal Nets and Addiction

    Directory of Open Access Journals (Sweden)

    Megan Slaker

    2016-01-01

    Full Text Available Exposure to drugs of abuse induces plasticity in the brain and creates persistent drug-related memories. These changes in plasticity and persistent drug memories are believed to produce aberrant motivation and reinforcement contributing to addiction. Most studies have explored the effect drugs of abuse have on pre- and postsynaptic cells and astrocytes; however, more recently, attention has shifted to explore the effect these drugs have on the extracellular matrix (ECM. Within the ECM are unique structures arranged in a net-like manner, surrounding a subset of neurons called perineuronal nets (PNNs. This review focuses on drug-induced changes in PNNs, the molecules that regulate PNNs, and the expression of PNNs within brain circuitry mediating motivation, reward, and reinforcement as it pertains to addiction.

  8. Army Net Zero Prove Out. Army Net Zero Training Report

    Science.gov (United States)

    2014-11-20

    sensors were strategically placed throughout the installation by magnetically attaching them to water main valve stems. The sensors check sound...Recycle Wrap  Substitutes for Packaging Materials  Re-Use of Textiles and Linens  Setting Printers to Double-Sided Printing Net Zero Waste...can effectively achieve source reduction. Clean and Re-Use Shop Rags - Shop rags represent a large textile waste stream at many installations. As a

  9. Army Net Zero Prove Out. Net Zero Waste Best Practices

    Science.gov (United States)

    2014-11-20

    Anaerobic Digesters – Although anaerobic digestion is not a new technology and has been used on a large-scale basis in wastewater treatment , the...technology and has been used on a large-scale basis in wastewater treatment , the use of the technology should be demonstrated with other...approaches can be used for cardboard and cellulose -based packaging materials. This approach is in line with the Net Zero Waste hierarchy in terms of

  10. Microbial activity in district cooling nets; Mikrobiell Aktivitet i Fjaerrkylenaet

    Energy Technology Data Exchange (ETDEWEB)

    Nordling, Magnus [Swedish Corrosion Inst., Stockholm (Sweden)

    2004-07-01

    Four district cooling nets with varying water quality have been investigated according to presence of microbially related problems. The aim has been to formulate recommendations regarding the water quality and regarding other procedures that might reduce the risk for biofilm formation and microbial corrosion. The method has consisted of using so called exposure containers, connected to each net. The water has been allowed to flow through the exposure containers where coupons of carbon steel have been exposed. The coupons have been withdrawn at different times, and analysed regarding the presence of biofilm and corrosion attack. Analyses have also been made regarding the amount of a number of different types of micro-organisms in the biofilm and in the district cooling water. The project has been divided in two phases. During the first phase of the project only two nets were investigated, one with municipal water and one with water of district heating quality, i.e. degassed and deionised. Biofilms could be seen on the coupons from both nets, even though the exposure time only had been 1.5 month. Considerable concentrations of micro-organisms were found in the biofilms and in the water for both nets, however much larger amounts for the net with municipal water. During the second phase of the project four nets were investigated, two with mainly municipal water and two with water of district heating quality. Here, on the other hand, it could be seen that the two nets with municipal water had micro-organisms of equivalent or lower concentrations compared to the two nets with water of district heating quality. One explanation to this is that the colouring substance pyranine is added to these two nets. Pyranine is added for the purpose of easily detecting a leakage but is at the same time a carbon compound, and as such a possible nutrient for the micro-organisms. This illustrates the importance of having the district cooling water as free from additives as possible. Other

  11. Army Net Zero Prove Out. Net Zero Energy Best Practices

    Science.gov (United States)

    2014-11-18

    energy which is then used to drive a heat engine to generate electrical power. Geothermal Power – These systems use thermal energy generated and...stored in the earth as a generating source for electricity. Several pilot installations are investigating this technology by conducting geothermal ...concentrate solar thermal energy which is then used to drive a heat engine to generate electrical power. • Geothermal Power - These systems use thermal energy

  12. Assessment of indoor heat stress variability in summer and during heat warnings: a case study using the UTCI in Berlin, Germany

    Science.gov (United States)

    Walikewitz, Nadine; Jänicke, Britta; Langner, Marcel; Endlicher, Wilfried

    2018-01-01

    Humans spend most of their time in confined spaces and are hence primarily exposed to the direct influence of indoor climate. The Universal Thermal Climate Index (UTCI) was obtained in 31 rooms (eight buildings) in Berlin, Germany, during summer 2013 and 2014. The indoor UTCI was determined from measurements of both air temperature and relative humidity and from data of mean radiant temperature and air velocity, which were either measured or modeled. The associated outdoor UTCI was obtained through facade measurements of air temperature and relative humidity, simulation of mean radiant temperature, and wind data from a central weather station. The results show that all rooms experienced heat stress according to UTCI levels, especially during heat waves. Indoor UTCI varied up to 6.6 K within the city and up to 7 K within building. Heat stress either during day or at night occurred on 35 % of all days. By comparing the day and night thermal loads, we identified maximum values above the 32 °C threshold for strong heat stress during the nighttime. Outdoor UTCI based on facade measurements provided no better explanation of indoor UTCI variability than the central weather station. In contrast, we found a stronger relationship of outdoor air temperature and indoor air temperature. Building characteristics, such as the floor level or window area, influenced indoor heat stress ambiguously. We conclude that indoor heat stress is a major hazard, and more effort toward understanding the causes and creating effective countermeasures is needed.

  13. Zero, normal and super-radiant modes for scalar and spinor fields in Kerr–anti de Sitter spacetime

    Science.gov (United States)

    Kenmoku, Masakatsu; Cho, Yongmin; Shigemoto, Kazuyasu; Yoon, Jong Hyuk

    2017-11-01

    We study zero and normal modes for scalar and spinor fields in Kerr–anti de Sitter spacetime as a bound state problem with Dirichlet and Neumann boundary conditions. Zero mode is defined as its momentum near the horizon to be zero: p_H=ω-Ω_Hm=0 , and is shown not to exist as a physical state for both scalar and spinor fields. Physical normal modes must satisfy the spectrum condition p_H>0 as results of (i) non-existence of zero mode and (ii) the analyticity with respect to the rotation parameter of Kerr–anti de Sitter spacetime. Under the spectrum condition, the super-radiant modes are shown to be type 2 super-radiance, which is characterized by negative frequency ω0 . The type 2 super-radiant modes are necessary for the completeness relation of normal modes and are stable. Applying the spectrum condition to black hole thermodynamics, the brick wall model is shown to be well-defined.

  14. Evaluation of Various Retrofitting Concepts of Building Envelope for Offices Equipped with Large Radiant Ceiling Panels by Dynamic Simulations

    Directory of Open Access Journals (Sweden)

    Sabina Jordan

    2015-09-01

    Full Text Available In order to achieve significant savings in energy and an improved level of thermal comfort in retrofitted existing buildings, specific retrofitting concepts that combine new technologies and design need to be developed and implemented. Large radiant surfaces systems are now among the most promising future technologies to be used both in retrofitted and in new low-energy buildings. These kinds of systems have been the topic of several studies dealing with thermal comfort and energy utilization, but some specific issues concerning their possible use in various concepts for retrofitting are still poorly understood. In the present paper, some results of dynamic simulations, with the transient system simulation tool (TRNSYS model, of the retrofitted offices equipped with radiant ceiling panels are presented and thoroughly analysed. Based on a precise comparison of the results of these simulations with actual measurements in the offices, certain input data for the model were added, so that the model was consequently validated. The model was then applied to the evaluation of various concepts of building envelopes for office retrofitting. By means of dynamic simulations of indoor environment it was possible to determine the benefits and limitations of individual retrofitting concepts. Some specific parameters, which are relevant to these concepts, were also identified.

  15. HANPP Collection: Human Appropriation of Net Primary Productivity as a Percentage of Net Primary Productivity

    Data.gov (United States)

    National Aeronautics and Space Administration — The Human Appropriation of Net Primary Productivity (HANPP) as a Percentage of Net Primary Productivity (NPP) portion of the Human Appropriation of Net Primary...

  16. Hydrodynamic characteristics of plane netting used for aquaculture net cages in uniform current

    National Research Council Canada - National Science Library

    DONG, SHUCHUANG; HU, FUXIANG; KUMAZAWA, TAISEI; SIODE, DAISUKE; TOKAI, TADASHI

    2016-01-01

      The hydrodynamic characteristics of polyethylene (PE) netting and chain link wire netting with different types of twine diameter and mesh size for aquaculture net cages were examined by experiments in a flume tank...

  17. Heat balance model for a human body in the form of wet bulb globe temperature indices.

    Science.gov (United States)

    Sakoi, Tomonori; Mochida, Tohru; Kurazumi, Yoshihito; Kuwabara, Kohei; Horiba, Yosuke; Sawada, Shin-Ichi

    2018-01-01

    The purpose of this study is to expand the empirically derived wet bulb globe temperature (WBGT) index to a rational thermal index based on the heat balance for a human body. We derive the heat balance model in the same form as the WBGT for a human engaged in moderate intensity work with a metabolic heat production of 174W/m 2 while wearing typical vapor-permeable clothing under shady and sunny conditions. Two important relationships are revealed based on this derivation: (1) the natural wet bulb and black globe temperature coefficients in the WBGT coincide with the heat balance equation for a human body with a fixed skin wettedness of approximately 0.45 at a fixed skin temperature; and (2) the WBGT can be interpreted as the environmental potential to increase skin temperature rather than the heat storage rate of a human body. We propose an adjustment factor calculation method that supports the application of WBGT for humans dressed in various clothing types and working under various air velocity conditions. Concurrently, we note difficulties in adjusting the WBGT by using a single factor for humans wearing vapor-impermeable protective clothing. The WBGT for shady conditions does not need adjustment depending on the positive radiant field (i.e., when a radiant heat source exists), whereas that for the sunny condition requires adjustments because it underestimates heat stress, which may result in insufficient human protection measures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Night time cooling by ventilation or night sky radiation combined with in-room radiant cooling panels including phase change materials

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Olesen, Bjarne W.; Grossule, Fabio

    constructed at the Technical University of Denmark, where the outside PVT panels are connected through a storage tank to in-room radiant ceiling panels. The radiant ceiling panels include phase change material (PCM) and embedded pipes for circulating water. Due to the phase change material it is possible...... through the night sky radiative cooling differed significantly. The possibility of night time ventilation was studied through simulations for three different latitudes. It was concluded that for Danish climatic conditions night time ventilation would also be able to regenerate the panels while its...

  19. Isolated unit tests in .Net

    OpenAIRE

    Haukilehto, Tero

    2013-01-01

    In this thesis isolation in unit testing is studied to get a precise picture of the isolation frameworks available for .Net environment. At the beginning testing is discussed in theory with the benefits and the problems it may have been linked with. The theory includes software development in general in connection with testing. Theory of isolation is also described before the actual isolation frameworks are represented. Common frameworks are described in more detail and comparable informa...

  20. Heat Stress

    Science.gov (United States)

    ... Publications and Products Programs Contact NIOSH NIOSH HEAT STRESS Recommend on Facebook Tweet Share Compartir NEW OSHA- ... hot environments may be at risk of heat stress. Exposure to extreme heat can result in occupational ...

  1. Development of net energy ratio for quad-generation pathways

    DEFF Research Database (Denmark)

    Rudra, Souman; Rosendahl, Lasse; Kumar, Amit

    2012-01-01

    The conversion of biomass to four different outputs via gasification and catalytic methanation is a renewable technology that could reduce the use of fossil fuels and GHG emissions. This study investigates the energy aspects of producing electricity, heat, methanol and methane. The Gas Technology......-based power, heat, methanol and methane production pathway using GTI technology. Since more efficient alternatives exist for the generation of heat and electricity from biomass, it is argued that syngas is best used for methanol production. The aim of this study was to evaluate the energy performance...... Institute (GTI) gasifier and Circulating Fluidized Bed (CFB) technologies are used for this quad generation process. Three different biomass feedstocks are considered in this study. The net energy ratio for six different pathways having the range of between 1.3–9.3. The lowest limit corresponds to the straw...

  2. Comparative Assessment of Satellite-Retrieved Surface Net Radiation: An Examination on CERES and SRB Datasets in China

    Directory of Open Access Journals (Sweden)

    Xin Pan

    2015-04-01

    Full Text Available Surface net radiation plays an important role in land–atmosphere interactions. The net radiation can be retrieved from satellite radiative products, yet its accuracy needs comprehensive assessment. This study evaluates monthly surface net radiation generated from the Clouds and the Earth’s Radiant Energy System (CERES and the Surface Radiation Budget project (SRB products, respectively, with quality-controlled radiation data from 50 meteorological stations in China for the period from March 2000 to December 2007. Our results show that surface net radiation is generally overestimated for CERES (SRB, with a bias of 26.52 W/m2 (18.57 W/m2 and a root mean square error of 34.58 W/m2 (29.49 W/m2. Spatially, the satellite-retrieved monthly mean of surface net radiation has relatively small errors for both CERES and SRB at inland sites in south China. Substantial errors are found at northeastern sites for two datasets, in addition to coastal sites for CERES. Temporally, multi-year averaged monthly mean errors are large at sites in western China in spring and summer, and in northeastern China in spring and winter. The annual mean error fluctuates for SRB, but decreases for CERES between 2000 and 2007. For CERES, 56% of net radiation errors come from net shortwave (NSW radiation and 44% from net longwave (NLW radiation. The errors are attributable to environmental parameters including surface albedo, surface water vapor pressure, land surface temperature, normalized difference vegetation index (NDVI of land surface proxy, and visibility for CERES. For SRB, 65% of the errors come from NSW and 35% from NLW radiation. The major influencing factors in a descending order are surface water vapor pressure, surface albedo, land surface temperature, NDVI, and visibility. Our findings offer an insight into error patterns in satellite-retrieved surface net radiation and should be valuable to improving retrieval accuracy of surface net radiation. Moreover, our

  3. Event hierarchies in DanNet

    DEFF Research Database (Denmark)

    Pedersen, Bolette Sandford; Nimb, Sanni

    2008-01-01

    Artiklen omhandler udarbejdelsen af et verbumshierarki i det leksikalsk-semantiske ordnet, DanNet.......Artiklen omhandler udarbejdelsen af et verbumshierarki i det leksikalsk-semantiske ordnet, DanNet....

  4. The Uniframe .Net Web Service Discovery Service

    National Research Council Canada - National Science Library

    Berbeco, Robert W

    2003-01-01

    Microsoft .NET allows the creation of distributed systems in a seamless manner Within NET small, discrete applications, referred to as Web services, are utilized to connect to each other or larger applications...

  5. Long Term RadNet Quality Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This RadNet Quality Data Asset includes all data since initiation and when ERAMS was expanded to become RadNet, name changed to reflect new mission. This includes...

  6. PsychoNet: a psycholinguistc commonsense ontology

    OpenAIRE

    Mohtasseb, Haytham; Ahmed, Amr

    2010-01-01

    Ontologies have been widely accepted as the most advanced knowledge representation model. This paper introduces PsychoNet, a new knowledgebase that forms the link between psycholinguistic taxonomy, existing in LIWC, and its semantic textual representation in the form of commonsense semantic ontology, represented by ConceptNet. The integration of LIWC and ConceptNet and the added functionalities facilitate employing ConceptNet in psycholinguistic studies. Furthermore, it simplifies utilization...

  7. 78 FR 72451 - Net Investment Income Tax

    Science.gov (United States)

    2013-12-02

    ... Revenue Service 26 CFR Part 1 RIN 1545-BL74 Net Investment Income Tax AGENCY: Internal Revenue Service...). These regulations provide guidance on the computation of net investment income. The regulations affect... lesser of: (A) The individual's net investment income for such taxable year, or (B) the excess (if any...

  8. 47 CFR 69.302 - Net investment.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Net investment. 69.302 Section 69.302... Apportionment of Net Investment § 69.302 Net investment. (a) Investment in Accounts 2001, 1220 and Class B Rural...) Investment in Accounts 2002, 2003 and to the extent such inclusions are allowed by this Commission, Account...

  9. 47 CFR 65.450 - Net income.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Net income. 65.450 Section 65.450... OF RETURN PRESCRIPTION PROCEDURES AND METHODOLOGIES Exchange Carriers § 65.450 Net income. (a) Net income shall consist of all revenues derived from the provision of interstate telecommunications services...

  10. 47 CFR 65.500 - Net income.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Net income. 65.500 Section 65.500... OF RETURN PRESCRIPTION PROCEDURES AND METHODOLOGIES Interexchange Carriers § 65.500 Net income. The net income methodology specified in § 65.450 shall be utilized by all interexchange carriers that are...

  11. NetBeans IDE 8 cookbook

    CERN Document Server

    Salter, David

    2014-01-01

    If you're a Java developer of any level using NetBeans and want to learn how to get the most out of NetBeans, then this book is for you. Learning how to utilize NetBeans will provide a firm foundation for your Java application development.

  12. Characterizing behavioural congruences for Petri nets

    DEFF Research Database (Denmark)

    Nielsen, Mogens; Priese, Lutz; Sassone, Vladimiro

    1995-01-01

    We exploit a notion of interface for Petri nets in order to design a set of net combinators. For such a calculus of nets, we focus on the behavioural congruences arising from four simple notions of behaviour, viz., traces, maximal traces, step, and maximal step traces, and from the corresponding...

  13. 27 CFR 4.37 - Net contents.

    Science.gov (United States)

    2010-04-01

    ... the volume of wine within the container, except that the following tolerances shall be allowed: (1... THE TREASURY LIQUORS LABELING AND ADVERTISING OF WINE Labeling Requirements for Wine § 4.37 Net contents. (a) Statement of net contents. The net contents of wine for which a standard of fill is...

  14. Crawl space assisted heat pump. [using stored ground heat

    Science.gov (United States)

    Ternes, M. P.

    1980-01-01

    A variety of experiments and simulations, currently being designed or underway, to determine the feasibility of conditioning the source air of an air to air heat pump using stored ground heat or cool to produce higher seasonal COP's and net energy savings are discussed. The ground would condition ambient air as it is drawn through the crawl space of a house. Tests designed to evaluate the feasibility of the concept, to determine the amount of heat or cool available from the ground, to study the effect of the system on the heating and cooling loads of the house, to study possible mechanisms which could enhance heat flow through the ground, and to determine if diurnal temperature swings are necessary to achieve successful system performance are described.

  15. A review of heat transfer phenomena and the impact of moisture on firefighters' clothing and protection.

    Science.gov (United States)

    Morel, Aude; Bedek, Gauthier; Salaün, Fabien; Dupont, Daniel

    2014-01-01

    Protective clothing with high insulation properties helps to keep the wearer safe from flames and other types of hazards. Such protection presents some drawbacks since it hinders movement and decreases comfort, in particular due to heat stress. In fact, sweating causes the accumulation of moisture which directly influences firefighters' performance, decreasing protection due to the increase in radiant heat flux. Vaporisation and condensation of hot moisture also induces skin burn. To evaluate the heat protection of protective clothing, Henrique's equation is used to predict the time leading to second-degree burn. The influence of moisture on protection is complex, i.e., at low radiant heat flux, an increase in moisture content increases protection, and also changes thermal properties. Better understanding of heat and mass transfer in protective clothing is required to develop enhanced protection and to prevent burn injuries. This paper aims to contribute to a better understanding of heat and mass transfer inside firefighters' protective clothing to enhance safety. The focus is on the influence of moisture content and the prevention of steam burn.

  16. Development and Demonstration of a High Efficiency, Rapid Heating, Low NOx Alternative to Conventional Heating of Round Steel Shapes, Steel Substrate (Strip) and Coil Box Transfer Bars

    Energy Technology Data Exchange (ETDEWEB)

    Kurek, Harry; Wagner, John

    2010-01-25

    Direct Flame Impingement involves the use of an array of very high-velocity flame jets impinging on a work piece to rapidly heat the work piece. The predominant mode of heat transfer is convection. Because of the locally high rate of heat transfer at the surface of the work piece, the refractory walls and exhaust gases of a DFI furnace are significantly cooler than in conventional radiant heating furnaces, resulting in high thermal efficiency and low NOx emissions. A DFI furnace is composed of a successive arrangement of heating modules through or by which the work piece is conveyed, and can be configured for square, round, flat, and curved metal shapes (e.g., billets, tubes, flat bars, and coiled bars) in single- or multi-stranded applications.

  17. Cast construction elements for heat treatment furnaces

    Directory of Open Access Journals (Sweden)

    B. Piekarski

    2011-07-01

    Full Text Available The study presents sketches and photos of the cast creep-resistant components used in various types of heat treatment furnaces. The shape of the elements results from the type of the operation carried out in the furnace, while dimensions are adjusted to the size of the furnace working chamber. The castings are mainly made from the high-alloyed, austenitic chromium-nickel or nickel-chromium steel, selecting the grade in accordance with the furnace operating conditions described by the rated temperature, the type and parameters of the applied operating atmosphere, and the charge weight. Typical examples in this family of construction elements are: crucibles, roller tracks, radiant tubes and guides. The majority of castings are produced in sand moulds.

  18. Disseny de calefacció amb terra radiant d'una casa a l'horta de Lleida mitjançant energia geotèrmica

    OpenAIRE

    Fillat Sobrino, Jordi

    2008-01-01

    S'ha realitzat el disseny de calefacció d'una vivenda mitjançant energia geotèrmica de baixa temperatura, amb un bescanviador vertical de 80 m de profunditat. El sistema de calefacció és de terra radiant en forma d'espiral.

  19. REVIEW ARTICLE: From single photons to milliwatt radiant power—electron storage rings as radiation sources with a high dynamic range

    Science.gov (United States)

    Klein, Roman; Thornagel, Reiner; Ulm, Gerhard

    2010-10-01

    The spectral radiant intensity of synchrotron radiation from electron storage rings can be calculated from basic electrodynamic relations (Schwinger equation) and it is directly proportional to the stored electron beam current, i.e. the number of stored electrons. With the necessary equipment installed to measure and control the electron beam current over a wide dynamic range, the radiant intensity of the synchrotron radiation can be adjusted accordingly without changing the spectrum. This is done, e.g., at the Metrology Light Source (MLS), the dedicated electron storage ring of the Physikalisch-Technische Bundesanstalt. The MLS is operated as a primary radiation source standard from the near IR up to the soft x-ray region and its operational parameters can be adjusted and accurately measured in a wide range: the electron beam current can be varied from 1 pA (one stored electron) up to 200 mA and thus the radiant intensity can be changed by more than 11 decades. The photon flux or radiant power for typical angular acceptances can thus be varied from single photons to milliwatts. This is a very powerful tool, e.g., for the characterization of the linearity of the response of radiation detectors or for the calibration of photon counting detectors. In this article we present an overview of past, current and possible future activities exploiting this feature.

  20. Full Scale Measurements and CFD Investigations of a Wall Radiant Cooling System Based on Plastic Capillary Tubes in Thin Concrete Walls

    DEFF Research Database (Denmark)

    Mikeska, Tomás; Fan, Jianhua; Svendsen, Svend

    2017-01-01

    Densely occupied spaces such as classrooms can very often have problems with overheating. It can be difficult to cool such spaces by means of a ventilation system without creating draughts and causing discomfort for occupants. The use of a wall radiant cooling system is a suitable option for spaces...

  1. NET 40 Generics Beginner's Guide

    CERN Document Server

    Mukherjee, Sudipta

    2012-01-01

    This is a concise, practical guide that will help you learn Generics in .NET, with lots of real world and fun-to-build examples and clear explanations. It is packed with screenshots to aid your understanding of the process. This book is aimed at beginners in Generics. It assumes some working knowledge of C# , but it isn't mandatory. The following would get the most use out of the book: Newbie C# developers struggling with Generics. Experienced C++ and Java Programmers who are migrating to C# and looking for an alternative to other generic frameworks like STL and JCF would find this book handy.

  2. The Net Reclassification Index (NRI)

    DEFF Research Database (Denmark)

    Pepe, Margaret S.; Fan, Jing; Feng, Ziding

    2015-01-01

    The Net Reclassification Index (NRI) is a very popular measure for evaluating the improvement in prediction performance gained by adding a marker to a set of baseline predictors. However, the statistical properties of this novel measure have not been explored in depth. We demonstrate the alarming...... marker is proven to erroneously yield a positive NRI. Some insight into this phenomenon is provided. Since large values for the NRI statistic may simply be due to use of poorly fitting risk models, we suggest caution in using the NRI as the basis for marker evaluation. Other measures of prediction...

  3. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  4. Experimental and empirical technique to estimate energy decreasing at heating in an oval furnace

    Directory of Open Access Journals (Sweden)

    A. A. Minea

    2012-10-01

    Full Text Available In this paper an experimental and empirical methods are proposed to estimate the heat transfer enhancement in industrial heating processes in oval furnaces. An investigation was conducted to study the suitability of inserting radiant panels of different positions and radiation surface. Two case studies were considered. The maximum energy saving was obtained for case 5: 32,89 % off from the standard experiment (with no panels. The minimum energy saving was obtained for case 10: 11,72 % off from the standard experiment (with no panels. Finally, based on the results of this study, a correlation was developed to predict the inner configuration of an oval furnace.

  5. Thermal analogies to Kepler's laws and their application to orbital heat transfer calculations

    Science.gov (United States)

    Buna, T.

    1974-01-01

    Integral expressions of radiant transfer in Keplerian orbits are developed in which quantities of heat are represented by areas swept over by thermal radii (presently introduced). The integrals are shown to be analogous in form to the solutions provided by Kepler's laws in orbital mechanics, when the radiation field is concentric with the gravitational field and possesses spherical symmetry. The more general case involving aspherical radiation fields and multiple heat sources is treated by graphical integration, using polar diagrams. Applications pertaining to the solar system and to the thermal balance of a conceptual Venus Radar Mapper Spacecraft are discussed.

  6. Net energy analysis: Powerful tool for selecting electric power options

    Science.gov (United States)

    Baron, S.

    A number of net energy analysis studies have been conducted in recent years for electric power production from coal, oil and uranium fuels; synthetic fuels from coal and oil shale; and heat and electric power from solar energy. This technique is an excellent indicator of investment costs, environmental impact and potential economic competitiveness of alternative electric power systems for energy planners from the Eastern European countries considering future options. Energy conservation is also important to energy planners and the net energy analysis technique is an excellent accounting system on the extent of energy resource conservation. The author proposes to discuss the technique and to present the results of his studies and others in the field. The information supplied to the attendees will serve as a powerful tool to the energy planners considering their electric power options in the future.

  7. Net energy analysis - powerful tool for selecting elective power options

    Energy Technology Data Exchange (ETDEWEB)

    Baron, S. [Brookhaven National Laboratory, Upton, NY (United States)

    1995-12-01

    A number of net energy analysis studies have been conducted in recent years for electric power production from coal, oil and uranium fuels; synthetic fuels from coal and oil shale; and heat and electric power from solar energy. This technique is an excellent indicator of investment costs, environmental impact and potential economic competitiveness of alternative electric power systems for energy planners from the Eastern European countries considering future options. Energy conservation is also important to energy planners and the net energy analysis technique is an excellent accounting system on the extent of energy resource conservation. The author proposes to discuss the technique and to present the results of his studies and others in the field. The information supplied to the attendees will serve as a powerful tool to the energy planners considering their electric power options in the future.

  8. Heat exchanger optimization for geothermal district heating systems: A fuel saving approach

    Energy Technology Data Exchange (ETDEWEB)

    Dagdas, Ahmet [Department of Mechanical Engineering, Yildiz Technical University, 34349 Besiktas, Istanbul (Turkey)

    2007-05-15

    One of the most commonly used heating devices in geothermal systems is the heat exchanger. The output conditions of heat exchangers are based on several parameters. The heat transfer area is one of the most important parameters for heat exchangers in terms of economics. Although there are a lot of methods to optimize heat exchangers, the method described here is a fairly easy approach. In this paper, a counter flow heat exchanger of geothermal district heating system is considered and optimum design values, which provide maximum annual net profit, for the considered heating system are found according to fuel savings. Performance of the heat exchanger is also calculated. In the analysis, since some values are affected by local conditions, Turkey's conditions are considered. (author)

  9. Feasibility of Achieving a Zero-Net-Energy, Zero-Net-Cost Homes

    Energy Technology Data Exchange (ETDEWEB)

    Al-Beaini, S.; Borgeson, S.; Coffery, B.; Gregory, D.; Konis, K.; Scown, C.; Simjanovic, J.; Stanley, J.; Strogen, B.; Walker, I.

    2009-09-01

    A green building competition, to be known as the Energy Free Home Challenge (EFHC), is scheduled to be opened to teams around the world in 2010. This competition will encourage both design innovation and cost reduction, by requiring design entries to meet 'zero net energy' and 'zero net cost' criteria. For the purposes of this competition, a 'zero net energy' home produces at least as much energy as it purchases over the course of a year, regardless of the time and form of the energy (e.g., electricity, heat, or fuel) consumed or produced. A 'zero net cost' home is no more expensive than a traditional home of comparable size and comfort, when evaluated over the course of a 30-year mortgage. In other words, the 'green premium' must have a payback period less than 30 years, based on the value of energy saved. The overarching goal of the competition is to develop affordable, high-performance homes that can be mass-produced at a large scale, and are able to meet occupant needs in harsh climates (as can be found where the competition will be held in Illinois). This report outlines the goals of the competition, and gauges their feasibility using both modeling results and published data. To ensure that the established rules are challenging, yet reasonable, this report seeks to refine the competition goals after exploring their feasibility through case studies, cost projections, and energy modeling. The authors of this report conducted a survey of the most progressive home energy-efficiency practices expected to appear in competition design submittals. In Appendix A, a summary can be found of recent projects throughout the United States, Canada, Germany, Switzerland, Sweden and Japan, where some of the most progressive technologies have been implemented. As with past energy efficient home projects, EFHC competitors will incorporate a multitude of energy efficiency measures into their home designs. The authors believe that

  10. High efficiency electric radiant holding furnaces on diecasting machines. Demonstration project at Fry's Diecastings Ltd. (London)

    Energy Technology Data Exchange (ETDEWEB)

    1985-10-01

    Savings of over pound 19,000, in direct fuel costs, were achieved at the London foundry of Fry's Diecastings Limited in the first year following the replacement of eight conventional crucible holding furnaces by electric radiant units. In addition, the total cost of replacement parts was reduced by an estimated pound 6,000 pa, to give total savings of over pound 25,000 pa. This represents a payback of 2.5 years on the company's investment. The gross energy saving in the first year of operation was 7,290 GJ equivalent to an 83% reduction in energy use. It is considered that these figures would be typical of other sites in the pressure diecasting sector where similar furnaces are operated for 1,500 production hours per year. (author).

  11. Technical and Economic Working Domains of Industrial Heat Pumps: Part 1 - Vapour Compression Heat Pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Jensen, Jonas Kjær; Markussen, Wiebke Brix

    2014-01-01

    the constraints of available refrigeration equipment and a requirement of a positive Net Present Value of the investment. The considered sink outlet temperature range is from 40 °C to 140 °C, but for the heat pumps considered in this paper, the upper limit is 100 °C. Five heat pumps are studied. For each set...

  12. Mars MetNet Mission - Martian Atmospheric Observational Post Network

    Science.gov (United States)

    Hari, Ari-Matti; Haukka, Harri; Aleksashkin, Sergey; Arruego, Ignacio; Schmidt, Walter; Genzer, Maria; Vazquez, Luis; Siikonen, Timo; Palin, Matti

    2017-04-01

    A new kind of planetary exploration mission for Mars is under development in collaboration between the Finnish Meteorological Institute (FMI), Lavochkin Association (LA), Space Research Institute (IKI) and Institutio Nacional de Tecnica Aerospacial (INTA). The Mars MetNet mission is based on a new semi-hard landing vehicle called MetNet Lander (MNL). The scientific payload of the Mars MetNet Precursor [1] mission is divided into three categories: Atmospheric instruments, Optical devices and Composition and structure devices. Each of the payload instruments will provide significant insights in to the Martian atmospheric behavior. The key technologies of the MetNet Lander have been qualified and the electrical qualification model (EQM) of the payload bay has been built and successfully tested. 1. MetNet Lander The MetNet landing vehicles are using an inflatable entry and descent system instead of rigid heat shields and parachutes as earlier semi-hard landing devices have used. This way the ratio of the payload mass to the overall mass is optimized. The landing impact will burrow the payload container into the Martian soil providing a more favorable thermal environment for the electronics and a suitable orientation of the telescopic boom with external sensors and the radio link antenna. It is planned to deploy several tens of MNLs on the Martian surface operating at least partly at the same time to allow meteorological network science. 2. Strawman Scientific Payload The strawman payload of the two MNL precursor models includes the following instruments: Atmospheric instruments: - MetBaro Pressure device - MetHumi Humidity device - MetTemp Temperature sensors Optical devices: - PanCam Panoramic - MetSIS Solar irradiance sensor with OWLS optical wireless system for data transfer - DS Dust sensor Composition and Structure Devices: Tri-axial magnetometer MOURA Tri-axial System Accelerometer The descent processes dynamic properties are monitored by a special 3-axis

  13. Net Surface Shortwave Radiation from GOES Imagery—Product Evaluation Using Ground-Based Measurements from SURFRAD

    Directory of Open Access Journals (Sweden)

    Anand K. Inamdar

    2015-08-01

    Full Text Available The Earth’s surface net radiation controls the energy and water exchanges between the Earth’s surface and the atmosphere, and can be derived from satellite observations. The ability to monitor the net surface radiation over large areas at high spatial and temporal resolution is essential for many applications, such as weather forecasting, short-term climate prediction or water resources management. The objective of this paper is to derive the net surface radiation in the shortwave domain at high temporal (half-hourly and spatial resolution (~1 km using visible imagery from Geostationary Operational Environmental Satellite (GOES. The retrieval algorithm represents an adaptation to GOES data of a standard algorithm initially developed for the NASA-operated Clouds and Earth’s Radiant Energy System (CERES scanner. The methodology relies on: (1 the estimation of top of atmosphere shortwave radiation from GOES spectral measurements; and (2 the calculation of net surface shortwave (SW radiation accounting for atmospheric effects. Comparison of GOES-retrieved net surface shortwave radiation with ground-measurements at the National Oceanic and Atmospheric Administration’s (NOAA Surface Radiation (SURFRAD stations yields very good agreement with average bias lower than 5 W·m−2 and root mean square difference around 70 W·m−2. The algorithm performance is usually higher over areas characterized by low spatial variability in term of land cover type and surface biophysical properties. The technique does not involve retrieval and assessment of cloud properties and can be easily adapted to other meteorological satellites around the globe.

  14. Energy Use Consequences of Ventilating a Net-Zero Energy House

    Science.gov (United States)

    Ng, Lisa C.; Payne, W. Vance

    2016-01-01

    A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved

  15. Energy Use Consequences of Ventilating a Net-Zero Energy House.

    Science.gov (United States)

    Ng, Lisa C; Payne, W Vance

    2016-03-05

    A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved

  16. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  17. -Net Approach to Sensor -Coverage

    Directory of Open Access Journals (Sweden)

    Fusco Giordano

    2010-01-01

    Full Text Available Wireless sensors rely on battery power, and in many applications it is difficult or prohibitive to replace them. Hence, in order to prolongate the system's lifetime, some sensors can be kept inactive while others perform all the tasks. In this paper, we study the -coverage problem of activating the minimum number of sensors to ensure that every point in the area is covered by at least sensors. This ensures higher fault tolerance, robustness, and improves many operations, among which position detection and intrusion detection. The -coverage problem is trivially NP-complete, and hence we can only provide approximation algorithms. In this paper, we present an algorithm based on an extension of the classical -net technique. This method gives an -approximation, where is the number of sensors in an optimal solution. We do not make any particular assumption on the shape of the areas covered by each sensor, besides that they must be closed, connected, and without holes.

  18. NETS - Danish participation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Alsen, S. (Grontmij - Carl Bro, Glostrup (Denmark)); Theel, C. (Baltic Sea Solutions, Holeby (Denmark))

    2008-12-15

    Within the NICe-funded project 'Nordic Environmental Technology Solutions (NETS)' a new type of networking at the Nordic level was organized in order to jointly exploit the rapidly growing market potential in the environmental technology sector. The project aimed at increased and professionalized commercialization of Nordic Cleantech in energy and water business segments through 1) closer cooperation and joint marketing activities, 2) a website, 3) cleantech product information via brochures and publications 4) and participating in relevant trade fairs and other industry events. Facilitating business-to-business activities was another core task for the NETS project partners from Norway, Sweden, Finland and Denmark with the aim to encourage total solutions for combined Cleantech system offers. The project has achieved to establish a Cleantech register of 600 Nordic Cleantech companies, a network of 86 member enterprises, produced several publications and brochures for direct technology promotion and a website for direct access to company profiles and contact data. The project partners have attended 14 relevant international Cleantech trade fairs and conferences and facilitated business-to-business contacts added by capacity building offers through two company workshops. The future challenge for the project partners and Nordic Cleantech will be to coordinate the numerous efforts within the Nordic countries in order to reach concerted action and binding of member companies for reliable services, an improved visibility and knowledge exchange. With Cleantech's growing market influence and public awareness, the need to develop total solutions is increasing likewise. Marketing efforts should be encouraged cross-sectional and cross-border among the various levels of involved actors from both the public and the private sector. (au)

  19. Coal-Fired Power Plant Heat Rate Reductions

    Science.gov (United States)

    View a report that identifies systems and equipment in coal-fired power plants where efficiency improvements can be realized, and provides estimates of the resulting net plant heat rate reductions and costs for implementation.

  20. Heat Saving Strategies in Sustainable Smart Energy Systems

    Directory of Open Access Journals (Sweden)

    Henrik Lund

    2014-06-01

    Full Text Available This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish governmental 2050 fossil-free vision, this paper identifies marginal heat production costs and compares these to marginal heat savings costs for two different levels of district heating. A suitable least-cost heating strategy seems to be to invest in an approximately 50% decrease in net heat demands in new buildings and buildings that are being renovated anyway, while the implementation of heat savings in buildings that are not being renovated hardly pays. Moreover, the analysis points in the direction that a least-cost strategy will be to provide approximately 2/3 of the heat demand from district heating and the rest from individual heat pumps.

  1. Application and Theory of Petri Nets

    DEFF Research Database (Denmark)

    This volume contains the proceedings of the 13th International Conference onApplication and Theory of Petri Nets, held in Sheffield, England, in June 1992. The aim of the Petri net conferences is to create a forum for discussing progress in the application and theory of Petri nets. Typically....... Balbo and W. Reisig, 18 submitted papers, and seven project papers. The submitted papers and project presentations were selectedby the programme committee and a panel of referees from a large number of submissions....

  2. Are You Neutral About Net Neutrality

    Science.gov (United States)

    2007-06-20

    Information Resources Management College National Defense University Are You Neutral About Net Neutrality ? A presentation for Systems & Software...author uses Verizon FiOS for phone, TV, and internet service 3 Agenda Net Neutrality —Through 2 Lenses Who Are the Players & What Are They Saying...Medical Treatment Mini-Case Studies Updates Closing Thoughts 4 Working Definitions of Net Neutrality "Network Neutrality" is the concept that

  3. Texture Based Image Analysis With Neural Nets

    Science.gov (United States)

    Ilovici, Irina S.; Ong, Hoo-Tee; Ostrander, Kim E.

    1990-03-01

    In this paper, we combine direct image statistics and spatial frequency domain techniques with a neural net model to analyze texture based images. The resultant optimal texture features obtained from the direct and transformed image form the exemplar pattern of the neural net. The proposed approach introduces an automated texture analysis applied to metallography for determining the cooling rate and mechanical working of the materials. The results suggest that the proposed method enhances the practical applications of neural nets and texture extraction features.

  4. Factors associated with mosquito net use by individuals in households owning nets in Ethiopia

    Directory of Open Access Journals (Sweden)

    Graves Patricia M

    2011-12-01

    Full Text Available Abstract Background Ownership of insecticidal mosquito nets has dramatically increased in Ethiopia since 2006, but the proportion of persons with access to such nets who use them has declined. It is important to understand individual level net use factors in the context of the home to modify programmes so as to maximize net use. Methods Generalized linear latent and mixed models (GLLAMM were used to investigate net use using individual level data from people living in net-owning households from two surveys in Ethiopia: baseline 2006 included 12,678 individuals from 2,468 households and a sub-sample of the Malaria Indicator Survey (MIS in 2007 included 14,663 individuals from 3,353 households. Individual factors (age, sex, pregnancy; net factors (condition, age, net density; household factors (number of rooms [2006] or sleeping spaces [2007], IRS, women's knowledge and school attendance [2007 only], wealth, altitude; and cluster level factors (rural or urban were investigated in univariate and multi-variable models for each survey. Results In 2006, increased net use was associated with: age 25-49 years (adjusted (a OR = 1.4, 95% confidence interval (CI 1.2-1.7 compared to children U5; female gender (aOR = 1.4; 95% CI 1.2-1.5; fewer nets with holes (Ptrend = 0.002; and increasing net density (Ptrend [all nets in HH good] = 1.6; 95% CI 1.2-2.1; increasing net density (Ptrend [per additional space] = 0.6, 95% CI 0.5-0.7; more old nets (aOR [all nets in HH older than 12 months] = 0.5; 95% CI 0.3-0.7; and increasing household altitude (Ptrend Conclusion In both surveys, net use was more likely by women, if nets had fewer holes and were at higher net per person density within households. School-age children and young adults were much less likely to use a net. Increasing availability of nets within households (i.e. increasing net density, and improving net condition while focusing on education and promotion of net use, especially in school-age children

  5. Pro Agile NET Development with Scrum

    CERN Document Server

    Blankenship, Jerrel; Millett, Scott

    2011-01-01

    Pro Agile .NET Development with SCRUM guides you through a real-world ASP.NET project and shows how agile methodology is put into practice. There is plenty of literature on the theory behind agile methodologies, but no book on the market takes the concepts of agile practices and applies these in a practical manner to an end-to-end ASP.NET project, especially the estimating, requirements and management aspects of a project. Pro Agile .NET Development with SCRUM takes you through the initial stages of a project - gathering requirements and setting up an environment - through to the development a

  6. Pro ASP.NET MVC 4

    CERN Document Server

    Freeman, Adam

    2012-01-01

    The ASP.NET MVC 4 Framework is the latest evolution of Microsoft's ASP.NET web platform. It provides a high-productivity programming model that promotes cleaner code architecture, test-driven development, and powerful extensibility, combined with all the benefits of ASP.NET. ASP.NET MVC 4 contains a number of significant advances over previous versions. New mobile and desktop templates (employing adaptive rendering) are included together with support for jQuery Mobile for the first time. New display modes allow your application to select views based on the browser that's making the request whi

  7. Professional Visual Basic 2010 and .NET 4

    CERN Document Server

    Sheldon, Bill; Sharkey, Kent

    2010-01-01

    Intermediate and advanced coverage of Visual Basic 2010 and .NET 4 for professional developers. If you've already covered the basics and want to dive deep into VB and .NET topics that professional programmers use most, this is your book. You'll find a quick review of introductory topics-always helpful-before the author team of experts moves you quickly into such topics as data access with ADO.NET, Language Integrated Query (LINQ), security, ASP.NET web programming with Visual Basic, Windows workflow, threading, and more. You'll explore all the new features of Visual Basic 2010 as well as all t

  8. NASA Net Zero Energy Buildings Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    Pless, S.; Scheib, J.; Torcellini, P.; Hendron, B.; Slovensky, M.

    2014-10-01

    In preparation for the time-phased net zero energy requirement for new federal buildings starting in 2020, set forth in Executive Order 13514, NASA requested that the National Renewable Energy Laboratory (NREL) to develop a roadmap for NASA's compliance. NASA detailed a Statement of Work that requested information on strategic, organizational, and tactical aspects of net zero energy buildings. In response, this document presents a high-level approach to net zero energy planning, design, construction, and operations, based on NREL's first-hand experience procuring net zero energy construction, and based on NREL and other industry research on net zero energy feasibility. The strategic approach to net zero energy starts with an interpretation of the executive order language relating to net zero energy. Specifically, this roadmap defines a net zero energy acquisition process as one that sets an aggressive energy use intensity goal for the building in project planning, meets the reduced demand goal through energy efficiency strategies and technologies, then adds renewable energy in a prioritized manner, using building-associated, emission- free sources first, to offset the annual energy use required at the building; the net zero energy process extends through the life of the building, requiring a balance of energy use and production in each calendar year.

  9. Towards a Standard for Modular Petri Nets

    DEFF Research Database (Denmark)

    Kindler, Ekkart; Petrucci, Laure

    2009-01-01

    When designing complex systems, mechanisms for structuring, composing, and reusing system components are crucial. Today, there are many approaches for equipping Petri nets with such mechanisms. In the context of defining a standard interchange format for Petri nets, modular PNML was defined....... Moreover, we present and discuss some more advanced features of modular Petri nets that could be included in the standard. This way, we provide a formal foundation and a basis for a discussion of features to be included in the upcoming standard of a module concept for Petri nets in general and for high...

  10. HEAT RECUPERATION

    Directory of Open Access Journals (Sweden)

    S. L. Rovin

    2011-01-01

    Full Text Available Heat recovery is an effective method of shortening specific energy consumption. new constructions of recuperators for heating and cupola furnaces have been designed and successfully introduced. two-stage recuperator with computer control providing blast heating up to 600 °C and reducing fuel consumption by 30% is of special interest.

  11. Energy performance of net-zero and near net-zero energy homes in New England

    Science.gov (United States)

    Thomas, Walter D.

    Net-Zero Energy Homes (NZEHs) are homes that consume no more energy than they produce on site during the course of a year. They are well insulated and sealed, use energy efficient appliances, lighting, and mechanical equipment, are designed to maximize the benefits from day lighting, and most often use a combination of solar hot water, passive solar and photovoltaic (PV) panels to produce their on-site energy. To date, NZEHs make up a miniscule percentage of homes in the United States, and of those, few have had their actual performance measured and analyzed once built and occupied. This research focused on 19 NZEHs and near net-zero energy homes (NNZEHs) built in New England. This set of homes had varying designs, numbers of occupants, and installed technologies for energy production, space heating and cooling, and domestic hot water systems. The author worked with participating homeowners to collect construction and systems specifications, occupancy information, and twelve months of energy consumption, production and cost measurements, in order to determine whether the homes reached their respective energy performance design goals. The author found that six out of ten NZEHs achieved net-zero energy or better, while all nine of the NNZEHs achieved an energy density (kWh/ft 2/person) at least half as low as the control house, also built in New England. The median construction cost for the 19 homes was 155/ft 2 vs. 110/ft2 for the US average, their average monthly energy cost was 84% below the average for homes in New England, and their estimated CO2 emissions averaged 90% below estimated CO2 emissions from the control house. Measured energy consumption averaged 14% below predictions for the NZEHs and 38% above predictions for the NNZEHs, while generated energy was within +/- 10% of predicted for 17 out of 18 on-site PV systems. Based on these results, the author concludes that these types of homes can meet or exceed their designed energy performance (depending on

  12. Colloidal heat engines: a review.

    Science.gov (United States)

    Martínez, Ignacio A; Roldán, Édgar; Dinis, Luis; Rica, Raúl A

    2016-12-21

    Stochastic heat engines can be built using colloidal particles trapped using optical tweezers. Here we review recent experimental realizations of microscopic heat engines. We first revisit the theoretical framework of stochastic thermodynamics that allows to describe the fluctuating behavior of the energy fluxes that occur at mesoscopic scales, and then discuss recent implementations of the colloidal equivalents to the macroscopic Stirling, Carnot and steam engines. These small-scale motors exhibit unique features in terms of power and efficiency fluctuations that have no equivalent in the macroscopic world. We also consider a second pathway for work extraction from colloidal engines operating between active bacterial reservoirs at different temperatures, which could significantly boost the performance of passive heat engines at the mesoscale. Finally, we provide some guidance on how the work extracted from colloidal heat engines can be used to generate net particle or energy currents, proposing a new generation of experiments with colloidal systems.

  13. Experiments and simulation of a net closing mechanism for tether-net capture of space debris

    Science.gov (United States)

    Sharf, Inna; Thomsen, Benjamin; Botta, Eleonora M.; Misra, Arun K.

    2017-10-01

    This research addresses the design and testing of a debris containment system for use in a tether-net approach to space debris removal. The tether-net active debris removal involves the ejection of a net from a spacecraft by applying impulses to masses on the net, subsequent expansion of the net, the envelopment and capture of the debris target, and the de-orbiting of the debris via a tether to the chaser spacecraft. To ensure a debris removal mission's success, it is important that the debris be successfully captured and then, secured within the net. To this end, we present a concept for a net closing mechanism, which we believe will permit consistently successful debris capture via a simple and unobtrusive design. This net closing system functions by extending the main tether connecting the chaser spacecraft and the net vertex to the perimeter and around the perimeter of the net, allowing the tether to actuate closure of the net in a manner similar to a cinch cord. A particular embodiment of the design in a laboratory test-bed is described: the test-bed itself is comprised of a scaled-down tether-net, a supporting frame and a mock-up debris. Experiments conducted with the facility demonstrate the practicality of the net closing system. A model of the net closure concept has been integrated into the previously developed dynamics simulator of the chaser/tether-net/debris system. Simulations under tether tensioning conditions demonstrate the effectiveness of the closure concept for debris containment, in the gravity-free environment of space, for a realistic debris target. The on-ground experimental test-bed is also used to showcase its utility for validating the dynamics simulation of the net deployment, and a full-scale automated setup would make possible a range of validation studies of other aspects of a tether-net debris capture mission.

  14. Mineralizing urban net-zero water treatment: Phase II field results and design recommendations

    Science.gov (United States)

    Net-zero water (NZW) systems, or water management systems achieving high recycling rates and low residuals generation so as to avoid water import and export, can also conserve energy used to heat and convey water, while economically restoring local eco-hydrology. However, design ...

  15. Regional atmospheric CO2 inversion reveals seasonal and geographic differences in Amazon net biome exchange

    NARCIS (Netherlands)

    Alden, Caroline B.; Miller, John B.; Gatti, Luciana V.; Gloor, Manuel M.; Guan, Kaiyu; Michalak, Anna M.; van der Laan-Luijkx, Ingrid T.; Touma, Danielle; Andrews, Arlyn; Basso, Luana S.; Correia, Caio S. C.; Domingues, Lucas G.; Joiner, Joanna; Krol, Maarten C.; Lyapustin, Alexei I.; Peters, Wouter; Shiga, Yoichi P.; Thoning, Kirk; van der Velde, Ivar R.; van Leeuwen, Thijs T.; Yadav, Vineet; Diffenbaugh, Noah S.

    2016-01-01

    Understanding tropical rainforest carbon exchange and its response to heat and drought is critical for quantifying the effects of climate change on tropical ecosystems, including global climate-carbon feedbacks. Of particular importance for the global carbon budget is net biome exchange of CO2 with

  16. Net Neutrality: A Fast Lane to Understanding the Trade-offs

    OpenAIRE

    Valletti, T; Peitz, M; Greenstein, S

    2016-01-01

    The "net neutrality" principle has triggered a heated debate and advocates have proposed policy interventions. In this paper, we provide perspective by framing issues in terms of the positive economic factors at work. We stress the incentives of market participants, and highlight the economic conflicts behind the arguments put forward by the different parties. We also identify several key open questions.

  17. Optimizing Sustainable Geothermal Heat Extraction

    Science.gov (United States)

    Patel, Iti; Bielicki, Jeffrey; Buscheck, Thomas

    2016-04-01

    Geothermal heat, though renewable, can be depleted over time if the rate of heat extraction exceeds the natural rate of renewal. As such, the sustainability of a geothermal resource is typically viewed as preserving the energy of the reservoir by weighing heat extraction against renewability. But heat that is extracted from a geothermal reservoir is used to provide a service to society and an economic gain to the provider of that service. For heat extraction used for market commodities, sustainability entails balancing the rate at which the reservoir temperature renews with the rate at which heat is extracted and converted into economic profit. We present a model for managing geothermal resources that combines simulations of geothermal reservoir performance with natural resource economics in order to develop optimal heat mining strategies. Similar optimal control approaches have been developed for managing other renewable resources, like fisheries and forests. We used the Non-isothermal Unsaturated-saturated Flow and Transport (NUFT) model to simulate the performance of a sedimentary geothermal reservoir under a variety of geologic and operational situations. The results of NUFT are integrated into the optimization model to determine the extraction path over time that maximizes the net present profit given the performance of the geothermal resource. Results suggest that the discount rate that is used to calculate the net present value of economic gain is a major determinant of the optimal extraction path, particularly for shallower and cooler reservoirs, where the regeneration of energy due to the natural geothermal heat flux is a smaller percentage of the amount of energy that is extracted from the reservoir.

  18. HANPP Collection: Human Appropriation of Net Primary Productivity as a Percentage of Net Primary Productivity

    Data.gov (United States)

    National Aeronautics and Space Administration — The Human Appropriation of Net Primary Productivity (HANPP) as a Percentage of Net Primary Product (NPP) portion of the HANPP Collection represents a map identifying...

  19. Price smarter on the Net.

    Science.gov (United States)

    Baker, W; Marn, M; Zawada, C

    2001-02-01

    Companies generally have set prices on the Internet in two ways. Many start-ups have offered untenably low prices in a rush to capture first-mover advantage. Many incumbents have simply charged the same prices on-line as they do off-line. Either way, companies are missing a big opportunity. The fundamental value of the Internet lies not in lowering prices or making them consistent but in optimizing them. After all, if it's easy for customers to compare prices on the Internet, it's also easy for companies to track customers' behavior and adjust prices accordingly. The Net lets companies optimize prices in three ways. First, it lets them set and announce prices with greater precision. Different prices can be tested easily, and customers' responses can be collected instantly. Companies can set the most profitable prices, and they can tap into previously hidden customer demand. Second, because it's so easy to change prices on the Internet, companies can adjust prices in response to even small fluctuations in market conditions, customer demand, or competitors' behavior. Third, companies can use the clickstream data and purchase histories that it collects through the Internet to segment customers quickly. Then it can offer segment-specific prices or promotions immediately. By taking full advantage of the unique possibilities afforded by the Internet to set prices with precision, adapt to changing circumstances quickly, and segment customers accurately, companies can get their pricing right. It's one of the ultimate drivers of e-business success.

  20. Geothermal heating from Pinkerton Hot Springs at Colorado Timberline Academy, Durango, Colorado. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Allen, C.C.; Allen, R.W.; Beldock, J.

    1981-11-08

    The efforts to establish a greater pool of knowledge in the field of low temperature heat transfer for the application of geothermal spring waters to space heating are described. A comprehensive set of heat loss experiments involving passive radiant heating panels is conducted and the results presented in an easily interpretable form. Among the conclusions are the facts that heating a 65 to 70 F/sup 0/ space with 90 to 100 F/sup 0/ liquids is a practical aim. The results are compared with the much lower rates published in the American Society of Heating Refrigeration and Air Conditioning Engineers SYSTEMS, 1976. A heat exchange chamber consisting of a 1000 gallon three compartment, insulated and buried tank is constructed and a control and pumping building erected over the tank. The tank is intended to handle the flow of geothermal waters from Pinkerton Hot Springs at 50 GPM prior to the wasting of the spring water at a disposal location. Approximately 375,000 Btu per hour should be available for heating assuming a 15 F/sup 0/ drop in water temperature. A combination of the panel heat loss experiments, construction of the heat exchange devices and ongoing collection of heat loss numbers adds to the knowledge available to engineers in sizing low temperature heat systems, useful in both solar and geothermal applications where source temperature may be often below 110 F/sup 0/.

  1. 78 FR 72393 - Net Investment Income Tax

    Science.gov (United States)

    2013-12-02

    ... Investment Income Tax; Final and Proposed Rules #0;#0;Federal Register / Vol. 78, No. 231 / Monday, December... Parts 1 and 602 RIN 1545-BK44 Net Investment Income Tax AGENCY: Internal Revenue Service (IRS), Treasury... Investment Income Tax and the computation of Net Investment Income. The regulations affect individuals...

  2. 77 FR 72611 - Net Investment Income Tax

    Science.gov (United States)

    2012-12-05

    ... December 5, 2012 Part V Department of the Treasury Internal Revenue Service 26 CFR Part 1 Net Investment... Investment Income Tax AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of proposed rulemaking...) the individual's net investment income for such taxable year, or (B) the excess (if any) of (i) the...

  3. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is

  4. Asynchronous stream processing with S-Net

    NARCIS (Netherlands)

    Grelck, C.; Scholz, S.-B.; Shafarenko, A.

    2010-01-01

    We present the rationale and design of S-Net, a coordination language for asynchronous stream processing. The language achieves a near-complete separation between the application code, written in any conventional programming language, and the coordination/communication code written in S-Net. Our

  5. Using the MVC architecture on . NET platform

    OpenAIRE

    Ježek, David

    2011-01-01

    This thesis deals with usage of MVC (Model View Controller) technology in web development on ASP.NET platform from Microsoft. Mainly it deals with latest version of framework ASP.NET MVC 3. First part describes MVC architecture and the second describes usage of MVC in certain parts of web application an comparing with PHP.

  6. Analysis of Petri Nets and Transition Systems

    Directory of Open Access Journals (Sweden)

    Eike Best

    2015-08-01

    Full Text Available This paper describes a stand-alone, no-frills tool supporting the analysis of (labelled place/transition Petri nets and the synthesis of labelled transition systems into Petri nets. It is implemented as a collection of independent, dedicated algorithms which have been designed to operate modularly, portably, extensibly, and efficiently.

  7. 27 CFR 7.27 - Net contents.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Net contents. 7.27 Section 7.27 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF... the net contents are displayed by having the same blown, branded, or burned in the container in...

  8. Petri nets and other models of concurrency

    DEFF Research Database (Denmark)

    Nielsen, Mogens; Sassone, Vladimiro

    1998-01-01

    This paper retraces, collects, and summarises contributions of the authors - in collaboration with others - on the theme of Petri nets and their categorical relationships to other models of concurrency.......This paper retraces, collects, and summarises contributions of the authors - in collaboration with others - on the theme of Petri nets and their categorical relationships to other models of concurrency....

  9. Delta Semantics Defined By Petri Nets

    DEFF Research Database (Denmark)

    Jensen, Kurt; Kyng, Morten; Madsen, Ole Lehrmann

    This report is identical to an earlier version of May 1978 except that Chapter 5 has been revised. A new paper: "A Petri Net Definition of a System Description Language", DAIMI, April 1979, 20 pages, extends the Petri net model to include a data state representing the program variables. Delta...

  10. Net neutrality and inflation of traffic

    NARCIS (Netherlands)

    Peitz, M.; Schütt, Florian

    Under strict net neutrality Internet service providers (ISPs) are required to carry data without any differentiation and at no cost to the content provider. We provide a simple framework with a monopoly ISP to evaluate the short-run effects of different net neutrality rules. Content differs in its

  11. Net Neutrality and Inflation of Traffic

    NARCIS (Netherlands)

    Peitz, M.; Schütt, F.

    2015-01-01

    Under strict net neutrality Internet service providers (ISPs) are required to carry data without any differentiation and at no cost to the content provider. We provide a simple framework with a monopoly ISP to evaluate different net neutrality rules. Content differs in its sensitivity to delay.

  12. The Net Neutrality Debate: The Basics

    Science.gov (United States)

    Greenfield, Rich

    2006-01-01

    Rich Greenfield examines the basics of today's net neutrality debate that is likely to be an ongoing issue for society. Greenfield states the problems inherent in the definition of "net neutrality" used by Common Cause: "Network neutrality is the principle that Internet users should be able to access any web content they choose and…

  13. Dynamic response of the thermometric net radiometer

    Science.gov (United States)

    J. D. Wilson; W. J. Massman; G. E. Swaters

    2009-01-01

    We computed the dynamic response of an idealized thermometric net radiometer, when driven by an oscillating net longwave radiation intended roughly to simulate rapid fluctuations of the radiative environment such as might be expected during field use of such devices. The study was motivated by curiosity as to whether non-linearity of the surface boundary conditions...

  14. Teaching and Learning with the Net Generation

    Science.gov (United States)

    Barnes, Kassandra; Marateo, Raymond C.; Ferris, S. Pixy

    2007-01-01

    As the Net Generation places increasingly greater demands on educators, students and teachers must jointly consider innovative ways of teaching and learning. In this, educators are supported by the fact that the Net Generation wants to learn. However, these same educators should not fail to realize that this generation learns differently from…

  15. Verification of Timed-Arc Petri Nets

    DEFF Research Database (Denmark)

    Jacobsen, Lasse; Jacobsen, Morten; Møller, Mikael Harkjær

    2011-01-01

    Timed-Arc Petri Nets (TAPN) are an extension of the classical P/T nets with continuous time. Tokens in TAPN carry an age and arcs between places and transitions are labelled with time intervals restricting the age of tokens available for transition firing. The TAPN model posses a number...

  16. A Brief Introduction to Coloured Petri Nets

    DEFF Research Database (Denmark)

    Jensen, Kurt

    1997-01-01

    Coloured Petri Nets (CP-nets or CPN) is a graphical oriented language for design, specification, simulation and verification of systems. It is in particular well- suited for systems in which communication, synchronisation and resource sharing are important. Typical examples of application areas a...

  17. Gill net and trammel net selectivity in the northern Aegean Sea, Turkey

    Directory of Open Access Journals (Sweden)

    F. Saadet Karakulak

    2008-09-01

    Full Text Available Fishing trials were carried out with gill nets and trammel nets in the northern Aegean Sea from March 2004 to February 2005. Four different mesh sizes for the gill nets and the inner panel of trammel nets (16, 18, 20 and 22 mm bar length were used. Selectivity parameters for the five most economically important species, bogue (Boops boops, annular sea bream (Diplodus annularis, striped red mullet (Mullus surmuletus, axillary sea bream (Pagellus acarne and blotched picarel (Spicara maena, caught by the two gears were estimated. The SELECT method was used to estimate the selectivity parameters of a variety of models. Catch composition and catch proportion of several species were different in gill and trammel nets. The length frequency distributions of the species caught by the two gears were significantly different. The bi-modal model selectivity curve gave the best fit for gill net and trammel net data, and there was little difference between the modal lengths of these nets. However, a clear difference was found in catching efficiency. The highest catch rates were obtained with the trammel net. Given that many discard species and small fish are caught by gill nets and trammel nets with a mesh size of 16 mm, it is clear that these nets are not appropriate for fisheries. Consequently, the best mesh size for multispecies fisheries is 18 mm. This mesh size will considerably reduce the numbers of small sized individuals and discard species in the catch.

  18. Heat Saving Strategies in Sustainable Smart Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Thellufsen, Jakob Zinck; Aggerholm, Søren

    2014-01-01

    This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish...... governmental 2050 fossil-free vision, this paper identifies marginal heat production costs and compares these to marginal heat savings costs for two different levels of district heating. A suitable least-cost heating strategy seems to be to invest in an approximately 50% decrease in net heat demands in new...... buildings and buildings that are being renovated anyway, while the implementation of heat savings in buildings that are not being renovated hardly pays. Moreover, the analysis points in the direction that a least-cost strategy will be to provide approximately 2/3 of the heat demand from district heating...

  19. Discrete, continuous, and hybrid petri nets

    CERN Document Server

    David, René

    2004-01-01

    Petri nets do not designate a single modeling formalism. In fact, newcomers to the field confess sometimes to be a little puzzled by the diversity of formalisms that are recognized under this "umbrella". Disregarding some extensions to the theoretical modeling capabilities, and looking at the level of abstraction of the formalisms, Condition/Event, Elementary, Place/Transition, Predicate/Transition, Colored, Object Oriented... net systems are frequently encountered in the literature. On the other side, provided with appropriate interpretative extensions, Controled Net Systems, Marking Diagrams (the Petri net generalization of State Diagrams), or the many-many variants in which time can be explicitly incorporated -Time(d), Deterministic, (Generalized) Stochastic, Fuzzy...- are defined. This represents another way to define practical formalisms that can be obtained by the "cro- product" of the two mentioned dimensions. Thus Petri nets constitute a modeling paradigm, understandable in a broad sense as "the total...

  20. Pro visual C++/CLI and the net 35 platform

    CERN Document Server

    Fraser, Stephen

    2008-01-01

    Pro Visual C++/CLI and the .NET 3.5 Platform is about writing .NET applications using C++/CLI. While readers are learning the ins and outs of .NET application development, they will also be learning the syntax of C++, both old and new to .NET. Readers will also gain a good understanding of the .NET architecture. This is truly a .NET book applying C++ as its development language not another C++ syntax book that happens to cover .NET.

  1. Intended and unintended effects of policy measures aimed at promoting net neutrality: an examination of the value chain for video distribution

    NARCIS (Netherlands)

    Nooren, P.; Leurdijk, A.; van Eijk, N.

    2012-01-01

    Net neutrality has, for a number of years, been a topic of often heated discussion in the Internet and telecom community. Net neutrality, in essence, requires that Internet users have open access to content and applications on the Internet, and, vice versa, that providers of applications can reach

  2. Heated Goggles

    Science.gov (United States)

    1978-01-01

    The electrically heated ski goggles shown incorporate technology similar to that once used in Apollo astronauts' helmet visors, and for the same reason-providing fogfree sight in an activity that demands total vision. Defogging is accomplished by applying heat to prevent moisture condensation. Electric heat is supplied by a small battery built into the h goggles' headband. Heat is spread across the lenses by means of an invisible coating of electrically conductive metallic film. The goggles were introduced to the market last fall. They were designed by Sierracin Corporation, Sylmar, California, specialists in the field of heated transparent materials. The company produces heated windshields for military planes and for such civil aircraft as the Boeing 747, McDonnell Douglas DC-10 and Lockheed L-1011 TriStar.

  3. Comparison of heating systems in a residential building

    Energy Technology Data Exchange (ETDEWEB)

    Veken, J.; Peeters, L.; Hens, H. [Leuven Catholic Univ., Leuven (Belgium). Laboratory of Building Physics

    2005-07-01

    Low temperature radiators, high temperature radiators and floor heating systems were compared via a case study approach in order to assess the overall efficiency between heating systems. The case study investigated the influence of radiant heating on temperature control as well as the introduction of an outside temperature sensor, insulation around piping, different boiler types and temperature profiles, such as night set back. The simulations were conducted using a TRNSYS16-model of a typical terraced house and compared four types of heating systems including, high temperature radiators, low temperature radiators, and two systems with floor heating in the day zone and temperature radiators in the night zone but differing in their floor capacity. The case study also investigated the influence of controlling the operative or air bulb temperature and the introduction of a condensing boiler possibly combined with a variable boiler exhaust temperature. It was concluded that floor heating systems do not outperform radiators, and only when coupled to condensing boilers, they consume less energy than the high temperature radiator system. Low temperature radiators perform best in all cases. 8 refs., 5 tabs., 6 figs.

  4. Optimal Management of Geothermal Heat Extraction

    Science.gov (United States)

    Patel, I. H.; Bielicki, J. M.; Buscheck, T. A.

    2015-12-01

    Geothermal energy technologies use the constant heat flux from the subsurface in order to produce heat or electricity for societal use. As such, a geothermal energy system is not inherently variable, like systems based on wind and solar resources, and an operator can conceivably control the rate at which heat is extracted and used directly, or converted into a commodity that is used. Although geothermal heat is a renewable resource, this heat can be depleted over time if the rate of heat extraction exceeds the natural rate of renewal (Rybach, 2003). For heat extraction used for commodities that are sold on the market, sustainability entails balancing the rate at which the reservoir renews with the rate at which heat is extracted and converted into profit, on a net present value basis. We present a model that couples natural resource economic approaches for managing renewable resources with simulations of geothermal reservoir performance in order to develop an optimal heat mining strategy that balances economic gain with the performance and renewability of the reservoir. Similar optimal control approaches have been extensively studied for renewable natural resource management of fisheries and forests (Bonfil, 2005; Gordon, 1954; Weitzman, 2003). Those models determine an optimal path of extraction of fish or timber, by balancing the regeneration of stocks of fish or timber that are not harvested with the profit from the sale of the fish or timber that is harvested. Our model balances the regeneration of reservoir temperature with the net proceeds from extracting heat and converting it to electricity that is sold to consumers. We used the Non-isothermal Unconfined-confined Flow and Transport (NUFT) model (Hao, Sun, & Nitao, 2011) to simulate the performance of a sedimentary geothermal reservoir under a variety of geologic and operational situations. The results of NUFT are incorporated into the natural resource economics model to determine production strategies that

  5. KONVERGENSI DALAM PROGRAM NET CITIZEN JOURNALISM

    Directory of Open Access Journals (Sweden)

    Rhafidilla Vebrynda

    2017-06-01

    Full Text Available Di dalam artikel ini, peneliti ingin melihat perkembangan teknologi di Indonesia sebagai sebuah peluang untuk menjalankan sebuah program berita berbasis video kiriman masyarakat. Perkembangan teknologi tersebut adalah teknologi penyiaran, teknologi sosial media dan teknologi dalam proses produksi sebuah video. Di Indonesia, jumlah televisi semakin banyak. Setiap stasiun televisi harus bersaing untuk dapat bertahan hidup. Net TV merupakan sebuah stasiun televisi baru di Indonesia yang harus memiliki berbagai program unggulan baru agar dapat bersaing dengan televisi lainnya yang sudah ada. Net TV menggunakan berbagai platform media untuk menjalankan program Net Citizen Journalism (Net CJ. Penggunaan berbagai platform media dikenal dengan istilah multiplatform dan secara teoritis dikenal dengan istilah konvergensi. Konvergensi yaitu saat meleburnya domain-domain dalam berbagai media komunikasi. Artikel ini menggunakan metode studi kasus untuk melihat bagaimana konvergensi terjadi dalam proses pengelolaan program Net CJ. Teknik pengumpulan data adalah dengan wawancara mendalam, observasi dan studi dokumen. Wawancara mendalam dilakukan dari tiga sudut pandang yaitu dari pengelola program, pengguna/audience dan pengamat media. Penelitian ini menemukan bahwa dengan menggunakan berbagai platform media yang fungsinya berbeda, memiliki satu tujuan yang sama yaitu untuk menjalankan program Net CJ. Adapun berbagai platform dalam proses produksi program yaitu tayangan TV konvensional, streaming TV, website, aplikasi Net CJ, facebook, twitter, instagram dan path. Konvergensi media dijalankan dalam dua proses, yaitu proses produksi dan proses promosi program berita.

  6. Net Neutrality: Media Discourses and Public Perception

    Directory of Open Access Journals (Sweden)

    Christine Quail

    2010-01-01

    Full Text Available This paper analyzes media and public discourses surrounding net neutrality, with particular attention to public utility philosophy, from a critical perspective. The article suggests that further public education about net neutrality would be beneficial. The first portion of this paper provides a survey of the existing literature surrounding net neutrality, highlighting the contentious debate between market-based and public interest perspectives. In order to contextualize the debate, an overview of public utility philosophy is provided, shedding light on how the Internet can be conceptualized as a public good. Following this discussion, an analysis of mainstream media is presented, exploring how the media represents the issue of net neutrality and whether or not the Internet is discussed through the lens of public utility. To further examine how the net neutrality debate is being addressed, and to see the potential impacts of media discourses on the general public, the results of a focus group are reported and analyzed. Finally, a discussion assesses the implications of the net neutrality debate as presented through media discourses, highlighting the future of net neutrality as an important policy issue.

  7. Approximation methods for stochastic petri nets

    Science.gov (United States)

    Jungnitz, Hauke Joerg

    1992-01-01

    Stochastic Marked Graphs are a concurrent decision free formalism provided with a powerful synchronization mechanism generalizing conventional Fork Join Queueing Networks. In some particular cases the analysis of the throughput can be done analytically. Otherwise the analysis suffers from the classical state explosion problem. Embedded in the divide and conquer paradigm, approximation techniques are introduced for the analysis of stochastic marked graphs and Macroplace/Macrotransition-nets (MPMT-nets), a new subclass introduced herein. MPMT-nets are a subclass of Petri nets that allow limited choice, concurrency and sharing of resources. The modeling power of MPMT is much larger than that of marked graphs, e.g., MPMT-nets can model manufacturing flow lines with unreliable machines and dataflow graphs where choice and synchronization occur. The basic idea leads to the notion of a cut to split the original net system into two subnets. The cuts lead to two aggregated net systems where one of the subnets is reduced to a single transition. A further reduction leads to a basic skeleton. The generalization of the idea leads to multiple cuts, where single cuts can be applied recursively leading to a hierarchical decomposition. Based on the decomposition, a response time approximation technique for the performance analysis is introduced. Also, delay equivalence, which has previously been introduced in the context of marked graphs by Woodside et al., Marie's method and flow equivalent aggregation are applied to the aggregated net systems. The experimental results show that response time approximation converges quickly and shows reasonable accuracy in most cases. The convergence of Marie's method and flow equivalent aggregation are applied to the aggregated net systems. The experimental results show that response time approximation converges quickly and shows reasonable accuracy in most cases. The convergence of Marie's is slower, but the accuracy is generally better. Delay

  8. Visual Studio 2010 and NET 4 Six-in-One

    CERN Document Server

    Novak, Istvan; Granicz, Adam

    2010-01-01

    Complete coverage of all key .NET 4 and Visual Studio 2010 languages and technologies. .NET 4 is Microsoft's latest version of their core programming platform, and Visual Studio 2010 is the toolset that helps write .NET 4 applications. This comprehensive resource offers one-stop shopping for all you need to know to get productive with .NET 4. Experienced author and .NET guru Mitchel Sellers reviews all the important new features of .NET 4, including .NET charting and ASP.NET charting, ASP.NET dynamic data and jQuery, and the addition of F# as a supported package language. The expansive coverag

  9. An Analysis on the Moisture and Thermal Protective Performance of Firefighter Clothing Based on Different Layer Combinations and Effect of Washing on Heat Protection and Vapour Transfer Performance

    Directory of Open Access Journals (Sweden)

    Ozgur Atalay

    2015-01-01

    Full Text Available Fabric assemblies for firefighting clothing have been tested for heat protection and comfort. The constituent materials and fabric structures have been specifically selected and tailored for firefighters’ clothing. In order to do this, four types of outer shell fabrics, four types of moisture barrier fabrics, and four types of heat barriers with different weights and material compositions were used to make a multilayered fabric assembly. Heat transfer (flame, heat transfer (radiant, and water vapour resistance tests were conducted according to the latest EN469 test standard which also recommends washing tests. These tests reveal that material content and material brand have considerable effect on the required performance levels of heat protection. In addition, while washing tests have improved water vapor transfer properties, they have a deteriorating effect on heat protection performance. Considering heat protection and moisture comfort properties, the optimal assemblies are thereby identified.

  10. Application and Theory of Petri Nets

    DEFF Research Database (Denmark)

    , the conferences have 150-200 participants, one third of these coming from industry and the rest from universities and research institutions. The 1992 conference was organized by the School of Computing and Management Sciences at Sheffield City Polytechnic, England. The volume contains twoinvited papers, by G......This volume contains the proceedings of the 13th International Conference onApplication and Theory of Petri Nets, held in Sheffield, England, in June 1992. The aim of the Petri net conferences is to create a forum for discussing progress in the application and theory of Petri nets. Typically...

  11. Performance Analysis using Coloured Petri Nets

    DEFF Research Database (Denmark)

    Wells, Lisa Marie

    an explicit separation between modelling the behaviour of a system and monitoring the behaviour of the model. As a result, cleaner and more understandable models can be created. The third paper presents a novel method for adding auxiliary information to coloured Petri net models. Coloured Petri nets models...... in a very limited and predictable manner, and it is easy to enable and disable the auxiliary information. The fourth paper is a case study in which the performance of a web server was analysed using coloured Petri nets. This case study has shown that it is relatively easy to analyse the performance...

  12. The KM3NeT project

    Energy Technology Data Exchange (ETDEWEB)

    Katz, U.F., E-mail: katz@physik.uni-erlangen.d [Erlangen Centre for Astroparticle Physics (ECAP), University of Erlangen-Nuernberg, Erwin-Rommel-Str. 1, 91058 Erlangen (Germany)

    2011-01-21

    The KM3NeT research infrastructure in the deep Mediterranean Sea will host a multi-cubic-kilometre neutrino telescope and provide connectivity for continuous, long-term measurements of earth and sea sciences, such as geology, marine biology and oceanography. The KM3NeT neutrino telescope will complement the IceCube telescope currently being installed at the South Pole in its field of view and surpass its sensitivity by a substantial factor. In this document the major aspects of the KM3NeT technical design are described and the expected physics sensitivity is discussed. Finally, the expected time line towards construction is presented.

  13. The net neutrality debate on Twitter

    Directory of Open Access Journals (Sweden)

    Wolf J. Schünemann

    2015-12-01

    Full Text Available The internet has been seen as a medium that empowers individual political actors in relation to established political elites and media gatekeepers. The present article discusses this “net empowerment hypothesis” and tests it empirically by analysing Twitter communication on the regulation of net neutrality. We extracted 503.839 tweets containing #NetNeutrality posted between January and March 2015 and analysed central developments and the network structure of the debate. The empirical results show that traditional actors from media and politics still maintain a central role.

  14. Heating plan for Denmark. Appendices; Varmeplan Danmark. Bilagsrapport

    Energy Technology Data Exchange (ETDEWEB)

    2008-10-15

    Today, district heating supplies 46% of the Danish net heating demand. The present report analyses whether it will be feasible for Denmark to extend the share of district heating or whether other alternatives are better. The analysis relates to the government's and parliament's plans to reduce Denmark's CO{sub 2} emission in the short term as well as to transfer the energy supply to be based fully on renewable energy sources in the long term. The appendix volume contains 15 appendices: 1) Heating map; 2) The potential of a future district heating extension; 3) The characteristics of the district heat distribution system; 4) Model for the Danish district heat distribution net; 5) Heating savings through extra insulation; 6) Supply to new built-up areas with district heating; 7) Supply to new built-up areas from central heating plants; 8) The potential of using waste heat; 9) The potential of using biogas; 10) The potential of using large scale solar heat; 11) Use of local straw resources; 12) Cogeneration optimization; 13) Scenario analyses; 14) The potential of cost effective heating savings; 15) Model of heating plan for Denmark (ln)

  15. Heat Stroke

    DEFF Research Database (Denmark)

    Mørch, Sofie Søndergaard; Andersen, Johnny Dohn Holmgren; Bestle, Morten Heiberg

    2017-01-01

    Heat stroke is an acute, life-threatening emergency characterized clinically by elevated body temperature and central nervous system dysfunction. Early recognition and treatment including aggressive cooling and management of life-threatening systemic complications are essential to reduce morbidity...... and mortality. This case report describes two Danish patients diagnosed with heat stroke syndrome during a heat wave in the summer of 2014. Both patients were morbidly obese and had several predisposing illnesses. However since heat stroke is a rare condition in areas with temperate climate, they were...... not diagnosed until several days after admittance; hence treatment with cooling was delayed. Both patients were admitted to the intensive care unit, where they were treated with an external cooling device and received treatment for complications. Both cases ended fatally. As global warming continues, more heat...

  16. Design of advanced solar homes aimed at net-zero annual energy consumption in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Athienitis, Andreas

    2010-09-15

    This paper overviews the design of three sustainable low or net-zero energy solar homes in Canada. The major features of the houses are: 1. direct gain passive solar design that emphasizes utilization of distributed thermal mass in the equatorial-facing part of the ground floor; 2. a building-integrated photovoltaic-thermal system (BIPV/T); 3. a two-stage ground-source heat pump used to heat/cool air in the house or an air source heat pump using BIPV/T air as the source to heat a storage tank; 4. a floor heating system integrated in the floor mass of the direct gain zone; 5. a multizone programmable thermostat.

  17. Planning long lasting insecticide treated net campaigns: should households' existing nets be taken into account?

    Science.gov (United States)

    Yukich, Joshua; Bennett, Adam; Keating, Joseph; Yukich, Rudy K; Lynch, Matt; Eisele, Thomas P; Kolaczinski, Kate

    2013-06-14

    Mass distribution of long-lasting insecticide treated bed nets (LLINs) has led to large increases in LLIN coverage in many African countries. As LLIN ownership levels increase, planners of future mass distributions face the challenge of deciding whether to ignore the nets already owned by households or to take these into account and attempt to target individuals or households without nets. Taking existing nets into account would reduce commodity costs but require more sophisticated, and potentially more costly, distribution procedures. The decision may also have implications for the average age of nets in use and therefore on the maintenance of universal LLIN coverage over time. A stochastic simulation model based on the NetCALC algorithm was used to determine the scenarios under which it would be cost saving to take existing nets into account, and the potential effects of doing so on the age profile of LLINs owned. The model accounted for variability in timing of distributions, concomitant use of continuous distribution systems, population growth, sampling error in pre-campaign coverage surveys, variable net 'decay' parameters and other factors including the feasibility and accuracy of identifying existing nets in the field. Results indicate that (i) where pre-campaign coverage is around 40% (of households owning at least 1 LLIN), accounting for existing nets in the campaign will have little effect on the mean age of the net population and (ii) even at pre-campaign coverage levels above 40%, an approach that reduces LLIN distribution requirements by taking existing nets into account may have only a small chance of being cost-saving overall, depending largely on the feasibility of identifying nets in the field. Based on existing literature the epidemiological implications of such a strategy is likely to vary by transmission setting, and the risks of leaving older nets in the field when accounting for existing nets must be considered. Where pre-campaign coverage

  18. Planning long lasting insecticide treated net campaigns: should households’ existing nets be taken into account?

    Science.gov (United States)

    2013-01-01

    Background Mass distribution of long-lasting insecticide treated bed nets (LLINs) has led to large increases in LLIN coverage in many African countries. As LLIN ownership levels increase, planners of future mass distributions face the challenge of deciding whether to ignore the nets already owned by households or to take these into account and attempt to target individuals or households without nets. Taking existing nets into account would reduce commodity costs but require more sophisticated, and potentially more costly, distribution procedures. The decision may also have implications for the average age of nets in use and therefore on the maintenance of universal LLIN coverage over time. Methods A stochastic simulation model based on the NetCALC algorithm was used to determine the scenarios under which it would be cost saving to take existing nets into account, and the potential effects of doing so on the age profile of LLINs owned. The model accounted for variability in timing of distributions, concomitant use of continuous distribution systems, population growth, sampling error in pre-campaign coverage surveys, variable net ‘decay’ parameters and other factors including the feasibility and accuracy of identifying existing nets in the field. Results Results indicate that (i) where pre-campaign coverage is around 40% (of households owning at least 1 LLIN), accounting for existing nets in the campaign will have little effect on the mean age of the net population and (ii) even at pre-campaign coverage levels above 40%, an approach that reduces LLIN distribution requirements by taking existing nets into account may have only a small chance of being cost-saving overall, depending largely on the feasibility of identifying nets in the field. Based on existing literature the epidemiological implications of such a strategy is likely to vary by transmission setting, and the risks of leaving older nets in the field when accounting for existing nets must be considered

  19. Surface renewal method for estimating sensible heat flux | Mengistu ...

    African Journals Online (AJOL)

    For short canopies, latent energy flux may be estimated using a shortened surface energy balance from measurements of sensible and soil heat flux and the net irradiance at the surface. The surface renewal (SR) method for estimating sensible heat, latent energy, and other scalar fluxes has the advantage over other ...

  20. Development of a carbon cloth heat post module for thermal vacuum testing of a spinning spacecraft

    Science.gov (United States)

    Levine, M. B.; Nelson, L. A.

    1972-01-01

    Development of a high temperature, high power density, isothermal, rapid transient, infrared thermal module is described. The investigation of various alternative approaches is discussed, as well as the rationale leading to the choice of a carbon cloth concept. Evolution of module design configurations and a summary of the development test results are included, along with a detailed description of the final design, which incorporated a black plate emitter radiantly heated by the carbon cloth. The final module configuration met design criteria during a 200-hour thermal vacuum performance test at 1000 F operating temperature without contaminating a solar cell array.

  1. Experimental investigation to simulate propellant heating in the nuclear light bulb engine.

    Science.gov (United States)

    Klein, J. F.

    1971-01-01

    Experiments to heat a simulated propellant to high bulk temperatures by the absorption of thermal radiation are discussed. Argon seeded with micron-sized carbon particles was used as the simulated propellant; a 500 kw d-c arc was used as the radiant energy source. Bulk temperatures up to 3860 K were obtained with greater than 95% of the incident radiation absorbed. The arc radiation source, seed dispersal equipment, techniques used to prevent transparent wall coating by the seeds, and calorimetric measurement of bulk temperature are also discussed.

  2. Infrared Radiation as Heat Transfer Mechanism of High Quality in Heating Processes La radiación infrarroja como mecanismo de transferencia de calor de alta calidad en procesos de calentamiento

    Directory of Open Access Journals (Sweden)

    Jose Luis Castañeda

    2012-12-01

    Full Text Available This paper tries to address the infrared radiation as a primary mechanismof heat transfer of high-quality in different heating processes, to highlightthe issues and applicability in the use, the characterization and design of thetechnologies powered by combustion systems. For this, it summarizes its phenomenology, definitions, assumptions and solutions; addresses some numericalmethods used to solve the Radiative Transfer Equation (RTE and its couplingto CFD codes (Computational Fluids Dynamics; as also the types of radiantequipment usually used, in especial the radiant tubes; as well as certain experimental methodologies used to characterize radiant systems, and some designmethodologies. It was found, that the flux model and the discrete transferare sufficient to give solution to the radiation heat transfer phenomenon withthe help of CFD codes, as well as the measuring device mainly used in experimental measurements is the radiometer, and the most practical designmethodology may be the optimization.En este artículo se pretende abordar la radiación infrarroja como un mecanismoprincipal de transferencia de calor de alta calidad en diferentes procesosde calentamiento, resaltar la pertenencia y problemática en el uso, la caracterizacióny el diseño de las tecnologías propias accionadas por sistemas decombustión. Para esto, se resume su fenomenología, sus definiciones, suposicionesy soluciones; se abordan algunos métodos numéricos utilizados parala solución de la ecuación de transferencia de radiación (Radiative TransferEquation (RTE y el acoplamiento de éstos a los códigos CFD (ComputationalFluids Dynamics; como también los tipos de equipos radiantes utilizadoscon mayor frecuencia, en especial los tubo radiantes; al igual que ciertas metodologíasexperimentales usadas para caracterizar los sistemas radiantes, yalgunas metodologías de diseño. Se encontró, que el modelo del flux y el de transferencias discretas son pertinentes

  3. A qualitative study on caretakers' perceived need of bed-nets after reduced malaria transmission in Zanzibar, Tanzania

    Directory of Open Access Journals (Sweden)

    Beer Netta

    2012-08-01

    heat barrier by using nets with larger mesh sizes and ensuring high bed-net ownership rates through sustainable and affordable delivery mechanisms.

  4. RadNet Air Quality (Deployable) Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet Deployable Monitoring is designed to collect radiological and meteorological information and data asset needed to establish the impact of radiation levels on...

  5. A Lightweight TwiddleNet Portal

    National Research Council Canada - National Science Library

    Rimikis, Antonios M

    2008-01-01

    TwiddleNet is a distributed architecture of personal servers that harnesses the power of the mobile devices, enabling real time information and file sharing of multiple data types from commercial-off-the-shelf platforms...

  6. Homology Groups of a Pipeline Petri Net

    Directory of Open Access Journals (Sweden)

    A. A. Husainov

    2013-01-01

    Full Text Available Petri net is said to be elementary if every place can contain no more than one token. In this paper, it is studied topological properties of the elementary Petri net for a pipeline consisting of n functional devices. If the work of the functional devices is considered continuous, we can come to some topological space of “intermediate” states. In the paper, it is calculated the homology groups of this topological space. By induction on n, using the Addition Sequence for homology groups of semicubical sets, it is proved that in dimension 0 and 1 the integer homology groups of these nets are equal to the group of integers, and in the remaining dimensions are zero. Directed homology groups are studied. A connection of these groups with deadlocks and newsletters is found. This helps to prove that all directed homology groups of the pipeline elementary Petri nets are zeroth.

  7. Net accumulation of the Greenland ice sheet

    DEFF Research Database (Denmark)

    Kiilsholm, Sissi; Christensen, Jens Hesselbjerg; Dethloff, Klaus

    2003-01-01

    improvement compared to the driving OAGCM. Estimates of the regional net balance are also better represented by the RCM. In the future climate the net balance for the Greenland Ice Sheet is reduced in all the simulation, but discrepancies between the amounts when based on ECHAM4/OPYC3 and HIRHAM are found....... In both scenarios, the estimated melt rates are larger in HIRHAM than in the driving model....

  8. CDMA and TDMA based neural nets.

    Science.gov (United States)

    Herrero, J C

    2001-06-01

    CDMA and TDMA telecommunication techniques were established long time ago, but they have acquired a renewed presence due to the rapidly increasing mobile phones demand. In this paper, we are going to see they are suitable for neural nets, if we leave the concept "connection" between processing units and we adopt the concept "messages" exchanged between them. This may open the door to neural nets with a higher number of processing units and flexible configuration.

  9. Mastering AngularJD for .NET developers

    CERN Document Server

    Majid, Mohammad Wadood

    2015-01-01

    This book is envisioned for traditional developers and programmers who want to develop client-side applications using the AngularJS framework and ASP.NET Web API 2 with Visual Studio. .NET developers who have already built web applications or web services and who have a fundamental knowledge of HTML, JavaScript, and CSS and want to explore single-page applications will also find this guide useful. Basic knowledge of AngularJS would be helpful.

  10. .NET 4.5 parallel extensions

    CERN Document Server

    Freeman, Bryan

    2013-01-01

    This book contains practical recipes on everything you will need to create task-based parallel programs using C#, .NET 4.5, and Visual Studio. The book is packed with illustrated code examples to create scalable programs.This book is intended to help experienced C# developers write applications that leverage the power of modern multicore processors. It provides the necessary knowledge for an experienced C# developer to work with .NET parallelism APIs. Previous experience of writing multithreaded applications is not necessary.

  11. A Lightweight TwiddleNet Portal

    Science.gov (United States)

    2008-03-01

    designed to exploit the multiple networking modalities available in the current generation of smartphones . TwiddleNet enables well-organized and well...of Sonopia and will have a comprehensive review of the service in the coming weeks [12]. Twango, which was acquired by Nokia in July 2007, is an...EXPERIMENTATION As already mentioned the main purpose of this thesis is the development of a TwiddleNet portal running on a smartphone or a PDA, which can allow

  12. CCS - and its relationship to net theory

    DEFF Research Database (Denmark)

    Nielsen, Mogens

    1987-01-01

    In this paper we give a short introduction to Milner's Calculus for Communicating Systems - a paradigm for concurrent computation. We put special emphasis on the basic concepts and tools from the underlying "algebraic approach", and their relationship to the approach to concurrency within net...... theory. Furthermore, we provide an operational version of the language CCS with "true concurrency" in the sense of net theory, and a discussion of the possible use of such a marriage of the two theories of concurrency....

  13. Heating plan for Denmark; Varmeplan Danmark

    Energy Technology Data Exchange (ETDEWEB)

    2008-10-15

    Today, district heating supplies 46% of the Danish net heating demand. The present report analyses whether it will be feasible for Denmark to extend the share of district heating or whether other alternatives are better. The analysis relates to the government's and parliament's plans to reduce Denmark's CO{sub 2} emission in the short term as well as to transfer the energy supply to be based fully on renewable energy sources in the long term. Calculations show that CO{sub 2} emissions from the heating sector can be halved by the year 2020, and that the sector can become almost CO{sub 2} neutral by around the year 2030. The prognosis for the year 2020 is 1) district heating supply is extended from 46% to about 60% of the market; 2) the consumers save further 25% of heat consumption and lowers the return temperature; 3) about 70% of all new buildings are supplied with district heat or heat from central heating plants; 4) the use of surplus heat during summer and the competition between different heating sources are increased through further coupling of the district heating systems; 5) the district heat production is extended using more heat storage, more renewable energy, and surplus heat, including heat from use of waste, cogeneration, biogas, solar energy, biomass, geothermal energy, heat pumps, and electric boilers for using surplus wind energy; 6) the CO{sub 2} emission from the heating sector is halved. To achieve this prognosis there are several challenges. The local governments must find a suitable delimitation between district heating and individual heat pumps where the advantages of district heating (efficiency and security of supply) are balanced against the relatively large investments in distribution networks. The district heating supplying sector must make the heat supply more efficient taking into account the consumers' possibilities to save heat consumption. The building owners must reduce the consumption of electric power, heat

  14. Visual Studio 2013 and .NET 4.5 expert cookbook

    CERN Document Server

    Sur, Abhishek

    2014-01-01

    If you are a Visual Studio 2013 or .NET developer who would like to sharpen your existing skill set and adapt to new .NET technologies, this is the book for you. A basic understanding of .NET and C# is required.

  15. HANPP Collection: Global Patterns in Net Primary Productivity (NPP)

    Data.gov (United States)

    National Aeronautics and Space Administration — The Global Patterns in Net Primary Productivity (NPP) portion of the Human Appropriation of Net Primary Productivity (HANPP) Collection maps the net amount of solar...

  16. Numerical prediction of radiative heat transfer in reciprocating superadiabatic combustion in porous media.

    Science.gov (United States)

    Du, Liming; Xie, Maozhao

    2011-06-01

    A numerical study of Reciprocating Superadiabatic Combustion of Premixed gases in porous media (hereafter, referred to as RSCP) is performed. In this system the transient combustion of methane-air mixture is stabilized in a porous media combustor by periodically switching flow directions. The mass, momentum, energy and species conservation equations are solved using a two-dimensional control volume method. Local thermal non-equilibrium between the gas and the solid phases is considered by solving separate energy equations for the two phases and coupling them through a convective heat transfer coefficient. The porous media is assumed to emit, absorb and isotropically scatter radiation. The influences of the dominating operating parameters, such as filtration velocity, equivalence ratio and half cycle on the temperature profile, heat release rate, radiant flux, radiant efficiency and combustion efficiency are discussed. The results show that coupling calculating of flow field, combustion reaction and volume radiation of the optically thick media is successively achieved and heat radiation plays an important role in the overall performance of the burner. The temperature profile inside the RSCP combustor has a typical trapezoidal shape and the profile of radiation flux is similar to sinusoidal shape. Compared with the conventional premixed combustion in porous medium, combustion behavior in RSCP combustor is superior, such as better thermal structure and higher radiation efficiency and combustion efficiency. Copyright © 2011 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  17. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1994-01-01

    It is approximately 10 years since the Third Edition of Heat Pipes was published and the text is now established as the standard work on the subject. This new edition has been extensively updated, with revisions to most chapters. The introduction of new working fluids and extended life test data have been taken into account in chapter 3. A number of new types of heat pipes have become popular, and others have proved less effective. This is reflected in the contents of chapter 5. Heat pipes are employed in a wide range of applications, including electronics cooling, diecasting and injection mo

  18. A new net primary production estimating model using NOAA-AVHRR applied to the Haihe Basin, China

    Science.gov (United States)

    Xu, Xingang; Wu, Bingfang; Li, Qiangzi; Meng, Jihua; Zhang, Fengli

    2006-10-01

    Terrestrial net primary production (NPP), as an important component of carbon cycle on land, not only indicates directly the production level of vegetation community on land, but also shows the status of terrestrial ecosystem. What's more, NPP is also a determinant of carbon sinks on land and a key regulator of ecological processes, including interactions among tropic levels. In the study, three existing models are combined with each other to assess net primary production in Haihe Basin, China. The photosynthetically active radiation (PAR) model of Monteith is used for the calculation of absorbed photosynthetically active radiation (APAR), the light utilization efficiency model of Potter et al. is used for determining the light utilization efficiency, and the surface energy balance system (SEBS) of Su is used into Potter's model to describe water stress in land wetness conditions. To assess NPP, We use NOAA-AVHRR data from November 2003 to September 2004 and the corresponding daily data of temperature and hours of sunshine obtained from meteorological stations in Haihe Basin, China. After atmospheric, geometrical and radiant corrections, every ten days NOAA data are processed to become an image of NDVI by means of the maximal value composition method (MVC) in order to eliminate some noises. Using these data, we compute NPP in spring season and spring season of 2004 in Haihe Basin, China. The result shows, in Haihe Basin, NPP for spring season is averaged to 336.10gC•m -2, and 709.16 gC•m -2 for autumn season. In spatial distribution, NPP is greater in both ends than in middle for spring season, and decrease increasingly from north to south for autumn season. Future work should rely on the integration of high and low resolution images to assess net primary production, which will probably have more accurately estimation.

  19. ASP.NET web API build RESTful web applications and services on the .NET framework

    CERN Document Server

    Kanjilal, Joydip

    2013-01-01

    This book is a step-by-step, practical tutorial with a simple approach to help you build RESTful web applications and services on the .NET framework quickly and efficiently.This book is for ASP.NET web developers who want to explore REST-based services with C# 5. This book contains many real-world code examples with explanations whenever necessary. Some experience with C# and ASP.NET 4 is expected.

  20. Thermal performance analysis of a solar heating plant

    DEFF Research Database (Denmark)

    Fan, Jianhua; Huang, Junpeng; Andersen, Ola Lie

    Detailed measurements were carried out on a large scale solar heating plant located in southern Denmark in order to evaluate thermal performances of the plant. Based on the measurements, energy flows of the plant were evaluated. A modified Trnsys model of the Marstal solar heating plant...... was developed to calculate thermal performances of the plant. In the Trnsys model, three solar collector fields with a total solar collector area of 33,300 m2, a seasonal water pit heat storage of 75,000 m3, a simplified CO2 HP, a simplified ORC unit and a simplified wood chip boiler were included. The energy...... consumption of the district heating net was modeled by volume flow rate and given forward and return temperatures of the district heating net. Weather data from a weather station at the site of the plant were used in the calculations. The Trnsys calculated yearly thermal performance of the solar heating plant...