WorldWideScience

Sample records for nerve agent ga

  1. An Important Chemical Weapon Group: Nerve Agents

    Directory of Open Access Journals (Sweden)

    Hakan Yaren

    2007-12-01

    Full Text Available As a result of developing modern chemistry, nerve agents, which are one of the most important group of efficient chemical warfare agents, were developed just before Second World War. They generate toxic and clinical effects via inhibiting acetylcholinesterase irreversibly and causing excessive amounts of acetylcholine at cholinergic synapses in the body. Clinical symptoms are occurred as a result of affected muscarinic (stimulation of secretuar glands, miosis, breathing problems etc., nicotinic (stimulation of skeletal muscles, paralyse, tremors etc. and central nerve system (convulsions, loss of consciousness, coma etc. areas. In case of a nerve agent exposure, treatment includes the steps of ventilation, decontamination, antidotal treatment (atropine, oximes, diazepam and pyridostigmine bromide and supportive theraphy. Because of arising possibility of using chemical warfare agents due to current conjuncture of the world, medical staff should know about nerve agents, their effects and how to treat the casualties exposured to nerve agents. [TAF Prev Med Bull 2007; 6(6.000: 491-500

  2. An Important Chemical Weapon Group: Nerve Agents

    Directory of Open Access Journals (Sweden)

    Hakan Yaren

    2007-12-01

    Full Text Available As a result of developing modern chemistry, nerve agents, which are one of the most important group of efficient chemical warfare agents, were developed just before Second World War. They generate toxic and clinical effects via inhibiting acetylcholinesterase irreversibly and causing excessive amounts of acetylcholine at cholinergic synapses in the body. Clinical symptoms are occurred as a result of affected muscarinic (stimulation of secretuar glands, miosis, breathing problems etc., nicotinic (stimulation of skeletal muscles, paralyse, tremors etc. and central nerve system (convulsions, loss of consciousness, coma etc. areas. In case of a nerve agent exposure, treatment includes the steps of ventilation, decontamination, antidotal treatment (atropine, oximes, diazepam and pyridostigmine bromide and supportive theraphy. Because of arising possibility of using chemical warfare agents due to current conjuncture of the world, medical staff should know about nerve agents, their effects and how to treat the casualties exposured to nerve agents. [TAF Prev Med Bull. 2007; 6(6: 491-500

  3. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    Science.gov (United States)

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  4. Chiral separation of G-type chemical warfare nerve agents via analytical supercritical fluid chromatography.

    Science.gov (United States)

    Kasten, Shane A; Zulli, Steven; Jones, Jonathan L; Dephillipo, Thomas; Cerasoli, Douglas M

    2014-12-01

    Chemical warfare nerve agents (CWNAs) are extremely toxic organophosphorus compounds that contain a chiral phosphorus center. Undirected synthesis of G-type CWNAs produces stereoisomers of tabun, sarin, soman, and cyclosarin (GA, GB, GD, and GF, respectively). Analytical-scale methods were developed using a supercritical fluid chromatography (SFC) system in tandem with a mass spectrometer for the separation, quantitation, and isolation of individual stereoisomers of GA, GB, GD, and GF. Screening various chiral stationary phases (CSPs) for the capacity to provide full baseline separation of the CWNAs revealed that a Regis WhelkO1 (SS) column was capable of separating the enantiomers of GA, GB, and GF, with elution of the P(+) enantiomer preceding elution of the corresponding P(-) enantiomer; two WhelkO1 (SS) columns had to be connected in series to achieve complete baseline resolution. The four diastereomers of GD were also resolved using two tandem WhelkO1 (SS) columns, with complete baseline separation of the two P(+) epimers. A single WhelkO1 (RR) column with inverse stereochemistry resulted in baseline separation of the GD P(-) epimers. The analytical methods described can be scaled to allow isolation of individual stereoisomers to assist in screening and development of countermeasures to organophosphorus nerve agents. © 2014 The Authors. Chirality published by John Wiley Periodicals, Inc.

  5. Graphene oxide/MnO2 nanocomposite as destructive adsorbent of nerve-agent simulants in aqueous media

    Czech Academy of Sciences Publication Activity Database

    Šťastný, Martin; Tolasz, Jakub; Štengl, Václav; Henych, Jiří; Žižka, D.

    2017-01-01

    Roč. 412, AUG (2017), s. 19-28 ISSN 0169-4332 R&D Projects: GA MŠk(CZ) LM2015073 Institutional support: RVO:61388980 Keywords : Graphene oxide * Manganese oxide * Nanocomposite * Destructive adsorption * Nerve agent simulants * Dimethyl methyl phosphonate (DMMP) * Triethyl phosphate (TEP) Subject RIV: CA - Inorganic Chemistry OBOR OECD: Inorganic and nuclear chemistry Impact factor: 3.387, year: 2016

  6. Behavioral effects of nerve agents: laboratory animal models

    International Nuclear Information System (INIS)

    Myers, T. M.

    2009-01-01

    Diverse and often subtle behavioral consequences have been reported for humans exposed to nerve agents. Laboratory studies of nerve agent exposure offer rigorous control over important variables, but species other than man must be used. Nonhuman primate models offer the best means of identifying the toxic nervous system effects of nerve agent insult and the countermeasures best capable of preventing or attenuating these effects. Comprehensive behavioral models must evaluate preservation and recovery of function as well as new learning ability. The throughput and sensitivity of the tests chosen are important considerations. A few nonhuman primate studies will be discussed to elaborate recent successes, current limitations, and future directions.(author)

  7. Organophosphate Nerve Agent Detection with Europium Complexes

    Directory of Open Access Journals (Sweden)

    Jake R. Schwierking

    2004-01-01

    Full Text Available We explore the detection of paraoxon, a model compound for nonvolatile organophosphate nerve agents such as VX. The detection utilizes europium complexes with 1,10 phenanthroline and thenoyltrifluoroacetone as sensitizing ligands. Both europium luminescence quenching and luminescence enhancement modalities are involved in the detection, which is simple, rapid, and sensitive. It is adaptable as well to the more volatile fluorophosphate nerve agents. It involves nothing more than visual luminescence observation under sample illumination by an ordinary hand-held ultraviolet lamp.

  8. Metal organic frameworks for the catalytic detoxification of chemical warfare nerve agents

    Science.gov (United States)

    Hupp, Joseph T.; Farha, Omar K.; Katz, Michael J.; Mondloch, Joseph E.

    2017-04-18

    A method of using a metal organic framework (MOF) comprising a metal ion and an at least bidendate organic ligand to catalytically detoxify chemical warfare nerve agents including exposing the metal-organic-framework (MOF) to the chemical warfare nerve agent and catalytically decomposing the nerve agent with the MOF.

  9. Improvements of the fluoride reactivation method for the verification of nerve agent exposure

    NARCIS (Netherlands)

    Degenhardt, C.E.A.M.; Pleijsier, K.; Schans, M.J. van der; Langenberg, J.P.; Preston, K.E.; Solano, M.I.; Maggio, V.L.; Barr, J.R.

    2004-01-01

    One of the most appropriate biomarkers for the verification of organophosphorus nerve agent exposure is the conjugate of the nerve agent to butyrylcholinesterase (BuChE). The phosphyl moiety of the nerve agent can be released from the BuChE enzyme by incubation with fluoride ions, after which the

  10. Zirconium Hydroxide-coated Nanofiber Mats for Nerve Agent Decontamination.

    Science.gov (United States)

    Kim, Sohee; Ying, Wu Bin; Jung, Hyunsook; Ryu, Sam Gon; Lee, Bumjae; Lee, Kyung Jin

    2017-03-16

    Diverse innovative fabrics with specific functionalities have been developed for requirements such as self-decontamination of chemical/biological pollutants and toxic nerve agents. In this work, Zr(OH) 4 -coated nylon-6,6 nanofiber mats were fabricated for the decontamination of nerve agents. Nylon-6,6 fabric was prepared via the electrospinning process, followed by coating with Zr(OH) 4 , which was obtained by the hydrolysis of Zr(OBu) 4 by a sol-gel reaction on nanofiber surfaces. The reaction conditions were optimized by varying the amounts of Zr(OBu) 4 ,the reaction time, and the temperature of the sol-gel reaction. The composite nanofibers show high decontamination efficiency against diisopropylfluorophosphate, which is a nerve agent analogue, due to its high nucleophilicity that aids in the catalysis of the hydrolysis of the phosphonate ester bonds. Composite nanofiber mats have a large potential and can be applied in specific fields such as military and medical markets. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Neuroprotection for Nerve Agent-Induced Brain Damage

    National Research Council Canada - National Science Library

    Newmark, Jonathan; Ballough, Gerald P; Filbert, Margaret G

    2002-01-01

    ... secondary to exposure to nerve agents. Preliminary work in this laboratory has demonstrated proof of concept using a compound not yet approved for clinical use by the US Food and Drug Administration...

  12. Nerve-Highlighting Fluorescent Contrast Agents for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Summer L. Gibbs-Strauss

    2011-03-01

    Full Text Available Nerve damage is the major morbidity of many surgeries, resulting in chronic pain, loss of function, or both. The sparing of nerves during surgical procedures is a vexing problem because surrounding tissue often obscures them. To date, systemically administered nerve-highlighting contrast agents that can be used for nerve-sparing image-guided surgery have not been reported. In the current study, physicochemical and optical properties of 4,4‘-[(2-methoxy-1,4-phenylenedi-(1E-2,1-ethenediyl]bis-benzenamine (BMB and a newly synthesized, red-shifted derivative 4-[(1E-2-[4-[(1E-2-[4-aminophenyl]ethenyl]-3-methoxyphenyl]ethenyl]-benzonitrile (GE3082 were characterized in vitro and in vivo. Both agents crossed the blood-nerve barrier and blood-brain barrier and rendered myelinated nerves fluorescent after a single systemic injection. Although both BMB and GE3082 also exhibited significant uptake in white adipose tissue, GE3082 underwent a hypsochromic shift in adipose tissue that provided a means to eliminate the unwanted signal using hyperspectral deconvolution. Dose and kinetic studies were performed in mice to determine the optimal dose and drug-imaging interval. The results were confirmed in rat and pig, with the latter used to demonstrate, for the first time, simultaneous fluorescence imaging of blood vessels and nerves during surgery using the FLARE™ (Fluorescence-Assisted Resection and Exploration imaging system. These results lay the foundation for the development of ideal nerve-highlighting fluorophores for image-guided surgery.

  13. Evaluating mice lacking serum carboxylesterase as a behavioral model for nerve agent intoxication.

    Science.gov (United States)

    Dunn, Emily N; Ferrara-Bowens, Teresa M; Chachich, Mark E; Honnold, Cary L; Rothwell, Cristin C; Hoard-Fruchey, Heidi M; Lesyna, Catherine A; Johnson, Erik A; Cerasoli, Douglas M; McDonough, John H; Cadieux, C Linn

    2018-06-07

    Mice and other rodents are typically utilized for chemical warfare nerve agent research. Rodents have large amounts of carboxylesterase in their blood, while humans do not. Carboxylesterase nonspecifically binds to and detoxifies nerve agent. The presence of this natural bioscavenger makes mice and other rodents poor models for studies identifying therapeutics to treat humans exposed to nerve agents. To obviate this problem, a serum carboxylesterase knockout (Es1 KO) mouse was created. In this study, Es1 KO and wild type (WT) mice were assessed for differences in gene expression, nerve agent (soman; GD) median lethal dose (MLD) values, and behavior prior to and following nerve agent exposure. No expression differences were detected between Es1 KO and WT mice in more than 34 000 mouse genes tested. There was a significant difference between Es1 KO and WT mice in MLD values, as the MLD for GD-exposed WT mice was significantly higher than the MLD for GD-exposed Es1 KO mice. Behavioral assessments of Es1 KO and WT mice included an open field test, a zero maze, a Barnes maze, and a sucrose preference test (SPT). While sex differences were observed in various measures of these tests, overall, Es1 KO mice behaved similarly to WT mice. The two genotypes also showed virtually identical neuropathological changes following GD exposure. Es1 KO mice appear to have an enhanced susceptibility to GD toxicity while retaining all other behavioral and physiological responses to this nerve agent, making the Es1 KO mouse a more human-like model for nerve agent research.

  14. Nerve Agents: What They Are, How They Work, How to Counter Them.

    Science.gov (United States)

    Costanzi, Stefano; Machado, John-Hanson; Mitchell, Moriah

    2018-05-16

    Nerve agents are organophosphorus chemical warfare agents that exert their action through the irreversible inhibition of acetylcholinesterase, with a consequent overstimulation of cholinergic transmission followed by its shutdown. Beyond warfare, they have notoriously been employed in acts of terrorism as well as high profile assassinations. After a brief historical introduction on the development and deployment of nerve agents, this review provides a survey of their chemistry, the way they affect cholinergic transmission, the available treatment options, and the current directions for their improvement. As the review illustrates, despite their merits, the currently available treatment options present several shortcomings. Current research directions involve the search for improved antidotes, antagonists of the nicotinic receptors, small-molecule pretreatment options, as well as bioscavengers as macromolecular pretreatment options. These efforts are making good progress in many different directions and, hopefully, will lead to a lower target susceptibility, thus reducing the appeal of nerve agents as chemical weapons.

  15. LABORATORY EXAMINATION IN NERVE AGENT INTOXICATION

    Directory of Open Access Journals (Sweden)

    Jiří Bajgar

    2013-01-01

    Full Text Available Diagnosis of nerve agent intoxication is based on anamnestic data, clinical signs and laboratory examination. For acute poisoning, cholinesterase activity in the blood (erythrocyte AChE, plasma/serum BuChE is sensitive, simple and most frequent laboratory examination performed in biochemical laboratories. Specialized examinations to precise treatment (reactivation test or to make retrospective diagnosis (fluoride induced reactivation etc. can be conducted. Other sophisticated methods are available, too.

  16. Evolution of and perspectives on therapeutic approaches to nerve agent poisoning.

    Science.gov (United States)

    Masson, Patrick

    2011-09-25

    After more than 70 years of considerable efforts, research on medical defense against nerve agents has come to a standstill. Major progress in medical countermeasures was achieved between the 50s and 70s with the development of anticholinergic drugs and carbamate-based pretreatment, the introduction of pyridinium oximes as antidotes, and benzodiazepines in emergency treatments. These drugs ensure good protection of the peripheral nervous system and mitigate the acute effects of exposure to lethal doses of nerve agents. However, pyridostigmine and cholinesterase reactivators currently used in the armed forces do not protect/reactivate central acetylcholinesterases. Moreover, other drugs used are not sufficiently effective in protecting the central nervous system against seizures, irreversible brain damages and long-term sequelae of nerve agent poisoning.New developments of medical counter-measures focus on: (a) detoxification of organophosphorus molecules before they react with acetylcholinesterase and other physiological targets by administration of stoichiometric or catalytic scavengers; (b) protection and reactivation of central acetylcholinesterases, and (c) improvement of neuroprotection following delayed therapy.Future developments will aim at treatment of acute and long-term effects of low level exposure to nerve agents, research on alternative routes for optimizing drug delivery, and therapies. Though gene therapy for in situ generation of bioscavengers, and cell therapy based on neural progenitor engraftment for neuronal regeneration have been successfully explored, more studies are needed before practical medical applications can be made of these new approaches. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Efficacy of antidotes (midazolam, atropine and HI-6) on nerve agent induced molecular and neuropathological changes

    OpenAIRE

    RamaRao, Golime; Afley, Prachiti; Acharya, Jyothiranjan; Bhattacharya, Bijoy Krishna

    2014-01-01

    Background Recent alleged attacks with nerve agent sarin on civilians in Syria indicate their potential threat to both civilian and military population. Acute nerve agent exposure can cause rapid death or leads to multiple and long term neurological effects. The biochemical changes that occur following nerve agent exposure needs to be elucidated to understand the mechanisms behind their long term neurological effects and to design better therapeutic drugs to block their multiple neurotoxic ef...

  18. REM sleep pathways and anticholinesterase intoxication: A mechanism for nerve agent-induced, central respiratory failure.

    NARCIS (Netherlands)

    Kok, A.

    1993-01-01

    The mechanism of death following exposure to anticholinesterases, such as the highly toxic nerve agents soman and VX, and other organophosphate anticholinesterases such as the insecticide parathion, remains unclear, although evidence from nerve agent research suggests that death occurs by an

  19. Nerve agent intoxication: Recent neuropathophysiological findings and subsequent impact on medical management prospects

    International Nuclear Information System (INIS)

    Collombet, Jean-Marc

    2011-01-01

    This manuscript provides a survey of research findings catered to the development of effective countermeasures against nerve agent poisoning over the past decade. New neuropathophysiological distinctive features as regards organophosphate (OP) intoxication are presented. Such leading neuropathophysiological features include recent data on nerve agent-induced neuropathology, related peripheral or central nervous system inflammation and subsequent angiogenesis process. Hence, leading countermeasures against OP exposure are down-listed in terms of pre-treatment, protection or decontamination and emergency treatments. The final chapter focuses on the description of the self-repair attempt encountered in lesioned rodent brains, up to 3 months after soman poisoning. Indeed, an increased proliferation of neuronal progenitors was recently observed in injured brains of mice subjected to soman exposure. Subsequently, the latter experienced a neuronal regeneration in damaged brain regions such as the hippocampus and amygdala. The positive effect of a cytokine treatment on the neuronal regeneration and subsequent cognitive behavioral recovery are also discussed in this review. For the first time, brain cell therapy and neuronal regeneration are considered as a valuable contribution towards delayed treatment against OP intoxication. To date, efficient delayed treatment was lacking in the therapeutic resources administered to patients contaminated by nerve agents. - Highlights: → This review focuses on neuropathophysiology following nerve agent poisoning in mice. → Extensive data on long-term neuropathology and related inflammation are provided here. → Delayed self-repair attempts encountered in lesioned rodent brains are also described. → Cell therapy is considered as a valuable treatment against nerve agent intoxication.

  20. Capillary gas chromatographic analysis of nerve agents using large volume injections

    NARCIS (Netherlands)

    Degenhardt, C.E.A.M.; Kientz, C.E.

    1996-01-01

    The use of large volume injections has been studied for the verification of intact organophosphorus chemical warfare agents in water samples. As the use of ethyl acetate caused severe detection problems new potential solvents were evaluated. With the developed procedure, the nerve agents sarin,

  1. Peripapillary Choroidal Neovascularization Associated with Optic Nerve Head Drusen Treated with Anti-VEGF Agents

    Directory of Open Access Journals (Sweden)

    Norman A. Saffra

    2015-02-01

    Full Text Available Optic nerve head drusen can be associated with peripapillary choroidal neovascularization, in both the pediatric and adult population. These membranes can involve the macula, causing significant visual loss. Herein, we present a case that required treatment with an anti-VEGF agent. The patient failed to respond to the initial agent, but subsequently responded to a change of agent. Adult patients with macular degeneration involving peripapillary choroidal neovascularization associated with optic nerve head drusen may require individualized treatment plans.

  2. Detoxification of organophosphate nerve agents by bacterial phosphotriesterase

    International Nuclear Information System (INIS)

    Ghanem, Eman; Raushel, Frank M.

    2005-01-01

    Organophosphates have been widely used as insecticides and chemical warfare agents. The health risks associated with these agents have necessitated the need for better detoxification and bioremediation tools. Bacterial enzymes capable of hydrolyzing the lethal organophosphate nerve agents are of special interest. Phosphotriesterase (PTE) isolated from the soil bacteria Pseudomonas diminuta displays a significant rate enhancement and substrate promiscuity for the hydrolysis of organophosphate triesters. Directed evolution and rational redesign of the active site of PTE have led to the identification of new variants with enhanced catalytic efficiency and stereoselectivity toward the hydrolysis of organophosphate neurotoxins. PTE has been utilized to protect against organophosphate poisoning in vivo. Biotechnological applications of PTE for detection and decontamination of insecticides and chemical warfare agents are developing into useful tools. In this review, the catalytic properties and potential applications of this remarkable enzyme are discussed

  3. Improved identification of cranial nerves using paired-agent imaging: topical staining protocol optimization through experimentation and simulation

    Science.gov (United States)

    Torres, Veronica C.; Wilson, Todd; Staneviciute, Austeja; Byrne, Richard W.; Tichauer, Kenneth M.

    2018-03-01

    Skull base tumors are particularly difficult to visualize and access for surgeons because of the crowded environment and close proximity of vital structures, such as cranial nerves. As a result, accidental nerve damage is a significant concern and the likelihood of tumor recurrence is increased because of more conservative resections that attempt to avoid injuring these structures. In this study, a paired-agent imaging method with direct administration of fluorophores is applied to enhance cranial nerve identification. Here, a control imaging agent (ICG) accounts for non-specific uptake of the nerve-targeting agent (Oxazine 4), and ratiometric data analysis is employed to approximate binding potential (BP, a surrogate of targeted biomolecule concentration). For clinical relevance, animal experiments and simulations were conducted to identify parameters for an optimized stain and rinse protocol using the developed paired-agent method. Numerical methods were used to model the diffusive and kinetic behavior of the imaging agents in tissue, and simulation results revealed that there are various combinations of stain time and rinse number that provide improved contrast of cranial nerves, as suggested by optimal measures of BP and contrast-to-noise ratio.

  4. Development of pretreatment compounds against nerve-gas agents. Annual report (Final), 16 May 88-30 Sep 90

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, F.I.; Abraham, P.

    1990-09-30

    The U. S. Army Medical Research and Development Command is interested in research directed toward the development of countermeasures to chemical warfare (CW) agents such as the nerve gas poison soman. Soman and other nerve gas poisons are extremely potent cholinesterase inhibitors. This inhibition leads to a buildup of excess acetylcholine resulting in over-stimulation of both the peripheral and central nervous system and can lead to death. Standard therapy for organophosphate nerve agent poisoning is based on co-administration of an anticholinergic agent such as atropine to antagonize the effects of accumulated acetylcholine and a cholinesterase reactivator such as 2-PAM to dephosphorylate the inhibited enzyme. However, since many problems remain in the treatment of organophosphate nerve agent poisoning, there is considerable interest and need to develop new pretreatment and treatment drugs, particularly for soman poisoning.

  5. Recent advances in evaluation of oxime efficacy in nerve agent poisoning by in vitro analysis

    International Nuclear Information System (INIS)

    Worek, F.; Eyer, P.; Aurbek, N.; Szinicz, L.; Thiermann, H.

    2007-01-01

    The availability of highly toxic organophosphorus (OP) warfare agents (nerve agents) underlines the necessity for an effective medical treatment. Acute OP toxicity is primarily caused by inhibition of acetylcholinesterase (AChE). Reactivators (oximes) of inhibited AChE are a mainstay of treatment, however, the commercially available compounds, obidoxime and pralidoxime, are considered to be rather ineffective against various nerve agents, e.g. soman and cyclosarin. This led to the synthesis and investigation of numerous oximes in the past decades. Reactivation of OP-inhibited AChE is considered to be the most important reaction of oximes. Clinical data from studies with pesticide-poisoned patients support the assumption that the various reactions between AChE, OP and oxime, i.e. inhibition, reactivation and aging, can be investigated in vitro with human AChE. In contrast to animal experiments such in vitro studies with human tissue enable the evaluation of oxime efficacy without being affected by species differences. In the past few years numerous in vitro studies were performed by different groups with a large number of oximes and methods were developed for extrapolating in vitro data to different scenarios of human nerve agent poisoning. The present status in the evaluation of new oximes as antidotes against nerve agent poisoning will be discussed

  6. Lab-on-a-chip for rapid electrochemical detection of nerve agent Sarin

    DEFF Research Database (Denmark)

    Tan, Hsih-Yin; Loke, Weng Keong; Nguyen, Nam-Trung

    2014-01-01

    This paper reports a lab-on-a-chip for the detection of Sarin nerve agent based on rapid electrochemical detection. The chemical warfare agent Sarin (C4H10FO2P, O-isopropyl methylphosphonofluoridate) is a highly toxic organophosphate that induces rapid respiratory depression, seizures and death...

  7. Evaluation of oxime efficacy in nerve agent poisoning: Development of a kinetic-based dynamic model

    International Nuclear Information System (INIS)

    Worek, Franz; Szinicz, Ladislaus; Eyer, Peter; Thiermann, Horst

    2005-01-01

    The widespread use of organophosphorus compounds (OP) as pesticides and the repeated misuse of highly toxic OP as chemical warfare agents (nerve agents) emphasize the necessity for the development of effective medical countermeasures. Standard treatment with atropine and the established acetylcholinesterase (AChE) reactivators, obidoxime and pralidoxime, is considered to be ineffective with certain nerve agents due to low oxime effectiveness. From obvious ethical reasons only animal experiments can be used to evaluate new oximes as nerve agent antidotes. However, the extrapolation of data from animal to humans is hampered by marked species differences. Since reactivation of OP-inhibited AChE is considered to be the main mechanism of action of oximes, human erythrocyte AChE can be exploited to test the efficacy of new oximes. By combining enzyme kinetics (inhibition, reactivation, aging) with OP toxicokinetics and oxime pharmacokinetics a dynamic in vitro model was developed which allows the calculation of AChE activities at different scenarios. This model was validated with data from pesticide-poisoned patients and simulations were performed for intravenous and percutaneous nerve agent exposure and intramuscular oxime treatment using published data. The model presented may serve as a tool for defining effective oxime concentrations and for optimizing oxime treatment. In addition, this model can be useful for the development of meaningful therapeutic animal models

  8. New 68Ga-PhenA bisphosphonates as potential bone imaging agents

    International Nuclear Information System (INIS)

    Wu, Zehui; Zha, Zhihao; Choi, Seok Rye; Plössl, Karl; Zhu, Lin; Kung, Hank F.

    2016-01-01

    Introduction: In vivo positron emission tomography (PET) imaging of the bone using [ 68 Ga]bisphosphonates may be a valuable tool for cancer diagnosis and monitoring therapeutic treatment. We have developed new [ 68 Ga]bisphosphonates based on the chelating group, AAZTA (6-[bis(hydroxycarbonyl-methyl)amino]-1,4-bis(hydroxycarbonyl methyl)-6-methylperhydro-1,4-diazepine). Method: Phenoxy derivative of AAZTA (2,2′-(6-(bis(carboxymethyl)amino)-6-((4-(2-carboxyethyl)phenoxy) methyl)-1,4-diazepane-1,4-diyl)diacetic acid), PhenA, 2, containing a bisphosphonate group (PhenA-BPAMD, 3, and PhenA-HBP, 4) was prepared. Labeling of these chelating agents with 68 Ga was evaluated. Results: The ligands reacted rapidly in a sodium acetate buffer with [ 68 Ga]GaCl 3 eluted from a commercially available 68 Ge/ 68 Ga generator (pH 4, > 95% labeling at room temperature in 5 min) to form [ 68 Ga]PhenA-BPAMD, 3, and [ 68 Ga]PhenA-HBP, 4. The improved labeling condition negates the need for further purification. The 68 Ga bisphosphonate biodistribution and autoradiography of bone sections in normal mice after an iv injection showed excellent bone uptake. Conclusion: New 68 Ga labeled bisphosphonates may be useful as in vivo bone imaging agents in conjunction with positron emission tomography (PET).

  9. The role of genetic background in susceptibility to chemical warfare nerve agents across rodent and non-human primate models.

    Science.gov (United States)

    Matson, Liana M; McCarren, Hilary S; Cadieux, C Linn; Cerasoli, Douglas M; McDonough, John H

    2018-01-15

    Genetics likely play a role in various responses to nerve agent exposure, as genetic background plays an important role in behavioral, neurological, and physiological responses to environmental stimuli. Mouse strains or selected lines can be used to identify susceptibility based on background genetic features to nerve agent exposure. Additional genetic techniques can then be used to identify mechanisms underlying resistance and sensitivity, with the ultimate goal of developing more effective and targeted therapies. Here, we discuss the available literature on strain and selected line differences in cholinesterase activity levels and response to nerve agent-induced toxicity and seizures. We also discuss the available cholinesterase and toxicity literature across different non-human primate species. The available data suggest that robust genetic differences exist in cholinesterase activity, nerve agent-induced toxicity, and chemical-induced seizures. Available cholinesterase data suggest that acetylcholinesterase activity differs across strains, but are limited by the paucity of carboxylesterase data in strains and selected lines. Toxicity and seizures, two outcomes of nerve agent exposure, have not been fully evaluated for genetic differences, and thus further studies are required to understand baseline strain and selected line differences. Published by Elsevier B.V.

  10. Quantification of VX Nerve Agent in Various Food Matrices by Solid-Phase Extraction Ultra-Performance Liquid ChromatographyTime-of-Flight Mass Spectrometry

    Science.gov (United States)

    2016-04-01

    QUANTIFICATION OF VX NERVE AGENT IN VARIOUS FOOD MATRICES BY SOLID - PHASE EXTRACTION ULTRA-PERFORMANCE...TITLE AND SUBTITLE Quantification of VX Nerve Agent in Various Food Matrices by Solid - Phase Extraction Ultra-Performance Liquid Chromatography...QUANTIFICATION OF VX NERVE AGENT IN VARIOUS FOOD MATRICES BY SOLID - PHASE EXTRACTION ULTRA-PERFORMANCE LIQUID CHROMATOGRAPHY–TIME-OF-FLIGHT MASS

  11. Comparison of oxime reactivation and aging of nerve agent-inhibited monkey and human acetylcholinesterases.

    Science.gov (United States)

    Luo, Chunyuan; Tong, Min; Maxwell, Donald M; Saxena, Ashima

    2008-09-25

    Non-human primates are valuable animal models that are used for the evaluation of nerve agent toxicity as well as antidotes and results from animal experiments are extrapolated to humans. It has been demonstrated that the efficacy of an oxime primarily depends on its ability to reactivate nerve agent-inhibited acetylcholinesterase (AChE). If the in vitro oxime reactivation of nerve agent-inhibited animal AChE is similar to that of human AChE, it is likely that the results of an in vivo animal study will reliably extrapolate to humans. Therefore, the goal of this study was to compare the aging and reactivation of human and different monkey (Rhesus, Cynomolgus, and African Green) AChEs inhibited by GF, GD, and VR. The oximes examined include the traditional oxime 2-PAM, two H-oximes HI-6 and HLo-7, and the new candidate oxime MMB4. Results indicate that oxime reactivation of all three monkey AChEs was very similar to human AChE. The maximum difference in the second-order reactivation rate constant between human and three monkey AChEs or between AChEs from different monkey species was 5-fold. Aging rate constants of GF-, GD-, and VR-inhibited monkey AChEs were very similar to human AChE except for GF-inhibited monkey AChEs, which aged 2-3 times faster than the human enzyme. The results of this study suggest that all three monkey species are suitable animal models for nerve agent antidote evaluation since monkey AChEs possess similar biochemical/pharmacological properties to human AChE.

  12. Enhancement of 67Ga tumor-to-blood ratios by chelating agent

    International Nuclear Information System (INIS)

    Saji, Hideo; Yokoyama, Akira; Hata, Naotaka; Misaki, Atsushi; Tanaka, Hisashi.

    1980-01-01

    Chelating agent, such as, CaEDTA, CaDTPA, D-penicillamine, DMSA, desferoxamine, NTA, cysteine ethyl ester, BAL, α-MPG, phthalein complexone, were tested as a possible contrast enhancing agent for tumor imaging with 67 Ga-citrate. The intravenous administration of a chelating agent to Ehrlich's tumor bearing mice, one hour after the injection of 67 Ga-citrate, accelerated the blood clearance with only a very slight change of activity in the target, increasing the tumor-to-blood ratio, and consequently achieving a better visualization. Among the tested chelating agents, D-penicillamine showed the highest target-to-nontarget ratio at a shorter time: a good tumor-to-blood ratio, performed after 24 hr with non-treated animals, was achieved in only 1-3 hr with post-treated animals. Thus, D-penicillamine hold a considerable promise as a contrast enhancing agent for future clinical use. (author)

  13. A structure-activity analysis of the variation in oxime efficacy against nerve agents

    International Nuclear Information System (INIS)

    Maxwell, Donald M.; Koplovitz, Irwin; Worek, Franz; Sweeney, Richard E.

    2008-01-01

    A structure-activity analysis was used to evaluate the variation in oxime efficacy of 2-PAM, obidoxime, HI-6 and ICD585 against nerve agents. In vivo oxime protection and in vitro oxime reactivation were used as indicators of oxime efficacy against VX, sarin, VR and cyclosarin. Analysis of in vivo oxime protection was conducted with oxime protective ratios (PR) from guinea pigs receiving oxime and atropine therapy after sc administration of nerve agent. Analysis of in vitro reactivation was conducted with second-order rate contants (k r2 ) for oxime reactivation of agent-inhibited acetylcholinesterase (AChE) from guinea pig erythrocytes. In vivo oxime PR and in vitro k r2 decreased as the volume of the alkylmethylphosphonate moiety of nerve agents increased from VX to cyclosarin. This effect was greater with 2-PAM and obidoxime (> 14-fold decrease in PR) than with HI-6 and ICD585 ( r2 as the volume of the agent moiety conjugated to AChE increased was consistent with a steric hindrance mechanism. Linear regression of log (PR-1) against log (k r2 · [oxime dose]) produced two offset parallel regression lines that delineated a significant difference between the coupling of oxime reactivation and oxime protection for HI-6 and ICD585 compared to 2-PAM and obidoxime. HI-6 and ICD585 appeared to be 6.8-fold more effective than 2-PAM and obidoxime at coupling oxime reactivation to oxime protection, which suggested that the isonicotinamide group that is common to both of these oximes, but absent from 2-PAM and obidoxime, is important for oxime efficacy

  14. REMOTE BIOSENSOR FOR IN SITU MONITORING OF ORGANOPHOSPHATE NERVE AGENTS. (R823663)

    Science.gov (United States)

    A remote electrochemical biosensor for field monitoring of organophosphate nerve agents is described. The new sensor relies on the coupling of the effective biocatalytic action of organophosphorus hydrolase (OPH) with a submersible amperometric probe design. This combination resu...

  15. Vesicants and nerve agents in chemical warfare. Decontamination and treatment strategies for a changed world.

    Science.gov (United States)

    Devereaux, Asha; Amundson, Dennis E; Parrish, J S; Lazarus, Angeline A

    2002-10-01

    Vesicants and nerve agents have been used in chemical warfare for ages. They remain a threat in today's altered political climate because they are relatively simple to produce, transport, and deploy. Vesicants, such as mustard and lewisite, can affect the skin, eyes, respiratory system, and gastrointestinal system. They leave affected persons at risk for long-term effects. Nerve agents, such as tabun, sarin, soman, and VX, hyperstimulate the muscarinic and nicotinic receptors of the nervous system. Physicians need to familiarize themselves with the clinical findings of such exposures and the decontamination and treatment strategies necessary to minimize injuries and deaths.

  16. Evaluation of Veriox as a Skin Decontamination Product after Dermal Exposure to the Nerve Agent VX

    Science.gov (United States)

    2016-09-01

    was to determine whether Veriox® had efficacy as a decontamination product (DC) after skin exposure to the chemical warfare agent VX. This study...countermeasure, decontamination , RSDL, VX, nerve agent, cutaneous exposure, chemical warfare agent 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...invested considerable resources in developing detectors, protective garments, and products to remove and/or decontaminate chemical agent exposure on

  17. In Search of an Effective in vivo Reactivator for Organophosphorus Nerve Agent-Inhibited Acetylcholinesterase in the Central Nervous System

    Science.gov (United States)

    2012-01-01

    nerve agents, such as sarin (GB), cyclosarin (GF), and VX, are potent inhibitors of the enzyme cholinesterase (ChE). Their toxic effects are due to...three nerve agents. Keywords: acetylcholinesterase; brain; cholinesterase inhibition; cholinesterase reactivation; cyclosarin; diacetylmonoxime...attributed, at least in part, to nuclophilic impedance [Ekstrom et al., 2006a; b; Hoskovcova et al., 2007]. Other AChE- inhibitors , such as soman, become

  18. Capillary gas chromatographic analysis of nerve agents using large volume injections. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Deinum, T.; Nieuwenhuy, C.

    1994-11-01

    The procedure developed at TNO-Prins Maurits Laboratory (TNO-PML) for the verification of intact organophosphorus chemical warfare agents in water samples was improved. The last step in this procedure, the laborious and non-reproducible transfer of an ethyl acetate extract onto a Tenax-adsorption tube followed by thermal desorption of the Tenax-tube, was replaced by large volume injection of the extract onto a capillary gas chromatographic system. The parameters controlling the injection of a large volume of an extract (200 ul) were investigated and optimized. As ethyl acetate caused severe problems, potential new solvents were evaluated. With the improved procedure, the nerve agents sarin, tabun, soman, diisopropyl fluorophosphate (DFP) and VX could be determined in freshly prepared water samples at pg/ml (ppt) levels. The fate of the nerve agents under study in water at two pH`s (4.8 and 6) was investigated. For VX, the pH should be adjusted before extraction. Moreover, it is worthwhile to acidify water samples to diminish hydrolysis.

  19. MMB4 DMS nanoparticle suspension formulation with enhanced stability for the treatment of nerve agent intoxication.

    Science.gov (United States)

    Dixon, Hong; Clark, Andrew P-Z; Cabell, Larry A; McDonough, Joe A

    2013-01-01

    Various oximes are currently fielded or under investigation in the United States and other countries as a component of autoinjector emergency treatment systems for organophosphate nerve agent chemical weapons. Bis-pyridinium oximes in general have greater efficacy against a broad spectrum of nerve agents, but they have poor stability due to hydrolytic degradation at elevated temperatures. 1,1'-Methylenebis-4-[(hydroxyimino)methyl]pyridinium dimethanesulfonate (MMB4 DMS) is a leading candidate for next-generation nerve agent treatment systems, because it is more stable than other bis-pyridinium oximes, but it still degrades quickly at temperatures often encountered during storage and field use. The primary goal is to increase the stability and shelf life of MMB4 while maintaining the desirable pharmacokinetic (PK) properties of the aqueous formulation. We have developed a formulation to be used in a phase 1 clinical trial consisting of MMB4 micro/nanoparticles suspended in cottonseed oil, a biocompatible vegetable oil. Through various milling techniques, the average particle size can be controlled from approximately 200 to 6000 nm to produce non-Newtonian formulations that are viscous enough to resist rapid particle sedimentation while remaining injectable at a range of concentrations from 5 to 400 mg/mL. The preliminary accelerated stability test shows that MMB4 in these formulations is stable for at least 2 years at temperatures up to 80°C. Preliminary preclinical in vivo studies have demonstrated that all concentrations and particle sizes have desirable PK properties, including high bioavailability and rapid absorption, which is critical to combat potent and fast-acting nerve agents.

  20. RSDL decontamination of human skin contaminated with the nerve agent VX.

    Science.gov (United States)

    Thors, L; Lindberg, S; Johansson, S; Koch, B; Koch, M; Hägglund, L; Bucht, A

    2017-03-05

    Dermal exposure to low volatile organophosphorus compounds (OPC) may lead to penetration through the skin and uptake in the blood circulation. Skin decontamination of toxic OPCs, such as pesticides and chemical warfare nerve agents, might therefore be crucial for mitigating the systemic toxicity following dermal exposure. Reactive skin decontamination lotion (RSDL) has been shown to reduce toxic effects in animals dermally exposed to the nerve agent VX. In the present study, an in vitro flow-through diffusion cell was utilized to evaluate the efficacy of RSDL for decontamination of VX exposed to human epidermis. In particular, the impact of timing in the initiation of decontamination and agent dilution in water was studied. The impact of the lipophilic properties of VX in the RSDL decontamination was additionally addressed by comparing chemical degradation in RSDL and decontamination efficacy between the VX and the hydrophilic OPC triethyl phosphonoacetate (TEPA). The epidermal membrane was exposed to 20, 75 or 90% OPC diluted in deionized water and the decontamination was initiated 5, 10, 30, 60 or 120min post-exposure. Early decontamination of VX with RSDL, initiated 5-10min after skin exposure, was very effective. Delayed decontamination initiated 30-60min post-exposure was less effective but still the amount of penetrated agent was significantly reduced, while further delayed start of decontamination to 120min resulted in very low efficacy. Comparing RSDL decontamination of VX with that of TEPA showed that the decontamination efficacy at high agent concentrations was higher for VX. The degradation mechanism of VX and TEPA during decontamination was dissected by 31 P NMR spectroscopy of the OPCs following reactions with RSDL and its three nucleophile components. The degradation rate was clearly associated with the high pH of the specific solution investigated; i.e. increased pH resulted in a more rapid degradation. In addition, the solubility of the OPC in RSDL

  1. Anticonvulsants for Nerve Agent-Induced Seizures: The Influence of the Therapeutic Dose of Atropine

    National Research Council Canada - National Science Library

    Shih, Tsung-Ming; Rowland, Tami C; McDonough, John H

    2007-01-01

    Two guinea pig models were used to study the anticonvulsant potency of diazepam, midazolam, and scopolamine against seizures induced by the nerve agents tabun, sarin, soman, cyclosarin, O-ethyl S-(2-(diisopropylamino)ethyl...

  2. α-Linolenic Acid, A Nutraceutical with Pleiotropic Properties That Targets Endogenous Neuroprotective Pathways to Protect against Organophosphate Nerve Agent-Induced Neuropathology

    Directory of Open Access Journals (Sweden)

    Tetsade Piermartiri

    2015-11-01

    Full Text Available α-Linolenic acid (ALA is a nutraceutical found in vegetable products such as flax and walnuts. The pleiotropic properties of ALA target endogenous neuroprotective and neurorestorative pathways in brain and involve the transcription factor nuclear factor kappa B (NF-κB, brain-derived neurotrophic factor (BDNF, a major neuroprotective protein in brain, and downstream signaling pathways likely mediated via activation of TrkB, the cognate receptor of BDNF. In this review, we discuss possible mechanisms of ALA efficacy against the highly toxic OP nerve agent soman. Organophosphate (OP nerve agents are highly toxic chemical warfare agents and a threat to military and civilian populations. Once considered only for battlefield use, these agents are now used by terrorists to inflict mass casualties. OP nerve agents inhibit the critical enzyme acetylcholinesterase (AChE that rapidly leads to a cholinergic crisis involving multiple organs. Status epilepticus results from the excessive accumulation of synaptic acetylcholine which in turn leads to the overactivation of muscarinic receptors; prolonged seizures cause the neuropathology and long-term consequences in survivors. Current countermeasures mitigate symptoms and signs as well as reduce brain damage, but must be given within minutes after exposure to OP nerve agents supporting interest in newer and more effective therapies. The pleiotropic properties of ALA result in a coordinated molecular and cellular program to restore neuronal networks and improve cognitive function in soman-exposed animals. Collectively, ALA should be brought to the clinic to treat the long-term consequences of nerve agents in survivors. ALA may be an effective therapy for other acute and chronic neurodegenerative disorders.

  3. Ultraviolet Raman scattering from persistent chemical warfare agents

    Science.gov (United States)

    Kullander, Fredrik; Wästerby, Pär.; Landström, Lars

    2016-05-01

    Laser induced Raman scattering at excitation wavelengths in the middle ultraviolet was examined using a pulsed tunable laser based spectrometer system. Droplets of chemical warfare agents, with a volume of 2 μl, were placed on a silicon surface and irradiated with sequences of laser pulses. The Raman scattering from V-series nerve agents, Tabun (GA) and Mustard gas (HD) was studied with the aim of finding the optimum parameters and the requirements for a detection system. A particular emphasis was put on V-agents that have been previously shown to yield relatively weak Raman scattering in this excitation band.

  4. Ga-doped and antisite double defects enhance the sensitivity of boron nitride nanotubes towards Soman and Chlorosoman

    Energy Technology Data Exchange (ETDEWEB)

    Javan, Masoud Bezi [Physics Department, Faculty of Sciences, Golestan University, Gorgan (Iran, Islamic Republic of); Soltani, Alireza, E-mail: Alireza.soltani46@yahoo.com [Golestan Rheumatology Research Center, Golestan University of Medical Science, Gorgan (Iran, Islamic Republic of); Young Researchers and Elite Club, Gorgan Branch, Islamic Azad University, Gorgan (Iran, Islamic Republic of); Ghasemi, A.S. [Department Chemistry, Payame Noor University, P.O. Box, 19395-3697, Tehran (Iran, Islamic Republic of); Lemeski, E.Tazikeh [Department of Chemistry, Gorgan Branch, Islamic Azad University, Gorgan (Iran, Islamic Republic of); Gholami, Niloofar [Young Researchers and Elite Club, Gorgan Branch, Islamic Azad University, Gorgan (Iran, Islamic Republic of); Balakheyli, Hanzaleh [Golestan Rheumatology Research Center, Golestan University of Medical Science, Gorgan (Iran, Islamic Republic of)

    2017-07-31

    Highlights: • Adsorptions of soman and chlorosoman over the BN nanotubes were investigated. • Adsorption energy of soman and chlorosoman on BGaNNT nanotube is more stable than B-BNNT. • BGaNNT can used to remove the toxic agents containing soman and chlorosoman molecules. • B-BNNT can detect the toxic agents containing soman and chlorosoman molecules. - Abstract: Adsorption of Soman and Chlorosoman over the outer surface of boron nitride nanotube (BNNT) was studied using density functional theory (DFT) calculations to consider its sensitivity toward mentioned nerve agents. Then, we studied the sensitivity of Ga-doped BNNT and double-antisite defective BNNT (d-BNNT) effects towards adsorbed molecule resulting in eye-catching sensitivity of defected adsorbents representing strong chemical adsorption on the Ga-doped BNNT, while they are mainly physisorbed on the pure BNNT with negligible electronic properties. Density of states (DOSs) was analyzed for further understanding of electronic properties of the applied configurations. Charges were moved from BNNT to the single molecules while in case of Ga-doped and d-BNNT; the charges were transferred from single molecules to the defected adsorbents. These along with outcomes of quantum molecular descriptors, difference in energy gap (E{sub g}), and dipole moments clearly reveal that the d-BNNT is a promising sensor material for the detection of these nerve agents.

  5. Polymeric Sorbent with Controlled Surface Polarity: An Alternate for Solid-Phase Extraction of Nerve Agents and Their Markers from Organic Matrix.

    Science.gov (United States)

    Roy, Kanchan Sinha; Purohit, Ajay Kumar; Chandra, Buddhadeb; Goud, D Raghavender; Pardasani, Deepak; Dubey, Devendra Kumar

    2018-06-05

    Extraction and identification of lethal nerve agents and their markers in complex organic background have a prime importance from the forensic and verification viewpoint of the Chemical Weapons Convention (CWC). Liquid-liquid extraction with acetonitrile and commercially available solid phase silica cartridges are extensively used for this purpose. Silica cartridges exhibit limited applicability for relatively polar analytes, and acetonitrile extraction shows limited efficacy toward relatively nonpolar analytes. The present study describes the synthesis of polymeric sorbents with tunable surface polarity, their application as a solid-phase extraction (SPE) material against nerve agents and their polar as well as nonpolar markers from nonpolar organic matrices. In comparison with the acetonitrile extraction and commercial silica cartridges, the new sorbent showed better extraction efficiency toward analytes of varying polarity. The extraction parameters were optimized for the proposed method, which included ethyl acetate as an extraction solvent and n-hexane as a washing solvent. Under optimized conditions, method linearity ranged from 0.10 to 10 μg mL -1 ( r 2 = 0.9327-0.9988) for organophosphorus esters and 0.05-20 μg mL -1 ( r 2 = 0.9976-0.9991) for nerve agents. Limits of detection (S:N = 3:1) in the SIM mode were found in the range of 0.03-0.075 μg mL -1 for organophosphorus esters and 0.015-0.025 μg mL -1 for nerve agents. Limits of quantification (S:N = 10:1) were found in the range of 0.100-0.25 μg mL -1 for organophosphorus esters and 0.05-0.100 μg mL -1 for nerve agents in the SIM mode. The recoveries of the nerve agents and their markers ranged from 90.0 to 98.0% and 75.0 to 95.0% respectively. The repeatability and reproducibility (with relative standard deviations (RSDs) %) for organophosphorus esters were found in the range of 1.35-8.61% and 2.30-9.25% respectively. For nerve agents, the repeatability range from 1.00 to 7.75% and reproducibility

  6. BIOSENSOR FOR DIRECT DETERMINATION OF ORGANOPHOSPHATE NERVE AGENTS. 1. POTENTIOMETRIC ENZYME ELECTRODE. (R823663)

    Science.gov (United States)

    A potentiometric enzyme electrode for the direct measurement of organophosphate (OP)nerve agents was developed. The basic element of this enzyme electrode was a pH electrodemodified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linkingOPH ...

  7. Preparation of Ga-68-NOTA as a renal PET agent and feasibility tests in mice

    International Nuclear Information System (INIS)

    Lee, Ji Youn; Jeong, Jae Min; Kim, Young Ju; Jeong, Hyuk-Jin; Lee, Yun-Sang; Lee, Dong Soo

    2014-01-01

    Introduction: Positron emission tomography (PET) may provide more accurate quantification of kidney function such as glomerular filtration rate (GFR) than gamma imaging. The purpose of these experiments was to prepare and evaluate Ga-68 complexes as potential PET agents for measurement of GFR. Methods: We labeled EDTA, DTPA, DOTA, and NOTA with Ga-68 obtained from a Ge-68/Ga-68-generator and measured the binding to serum and red blood cells. Biodistribution study was performed in male BALB/c mice after intravenous injection together with Cr-51-EDTA as the standard for glomerular filtration rate (GFR) measurement. Animal-PET study was performed using BALB/c mice. Results: All the tested chelating agents except DTPA showed quantitative labeling yields (> 99%). Among them, Ga-68-NOTA showed consistently low binding to both human and mouse RBC and serum protein. Biodistribution study showed no significant difference between Ga-68-NOTA and Cr-51-EDTA groups by one-way analysis of variance (ANOVA) (p > 0.05). Furthermore, the GFR values obtained by Ga-68-NOTA and Cr-51-EDTA were almost same (0.26 ± 0.04 and 0.25 ± 0.04 mL/min, respectively). Animal-PET study showed almost the same GFR (0.25 mL/min) with the values obtained by biodistribution study. Conclusion: We proved that an easy-to-prepare agent Ga-68-NOTA is ideal for renal PET as well as for GFR measurement

  8. Relationship Between the Dose-Response Curves for Lethality and Severe Effects for Chemical Warfare Nerve Agents

    National Research Council Canada - National Science Library

    Sommerville, Douglas R

    2005-01-01

    ... (involving acute inhalation exposures to G-type nerve agents) were reviewed and analyzed. For all three studies, slightly more than one standard deviation separated an effective concentration (ECxx...

  9. A Structure-Activity Analysis of the Variation in Oxime Efficacy Against Nerve Agents

    Science.gov (United States)

    2008-01-01

    cyclosarin. Analysis of in vivo oxime protection was conducted with oxime protective ratios (PR) from guinea pigs receiving oxime and atropine therapy ...in our study confirmed previous assessments that oxime protection varies drama - tically against different military nerve agents (Aas, 2003; Dawson... therapy ofacutepoisonings inducedbyanti-cholinesterase neuroparalytic substances. In:Monov, A., Dishovsky, C. (Eds.), Medical Aspects of Chemical and

  10. Evaluating of the Anticonvulsant Gabapentin against Nerve Agent-Induced Seizures in a Guinea Pig Model

    Science.gov (United States)

    2010-07-01

    treating neuropathic pain. This study evaluated whether gabapentin could terminate or moderate nerve agent-induced seizures using a validated guinea ... pig model. Male Hartley guinea pigs were surgically prepared to record electroencephalographic (EEG) activity. After a week recovery, animals were

  11. Efficacy of antidotes (midazolam, atropine and HI-6) on nerve agent induced molecular and neuropathological changes.

    Science.gov (United States)

    RamaRao, Golime; Afley, Prachiti; Acharya, Jyothiranjan; Bhattacharya, Bijoy Krishna

    2014-04-04

    Recent alleged attacks with nerve agent sarin on civilians in Syria indicate their potential threat to both civilian and military population. Acute nerve agent exposure can cause rapid death or leads to multiple and long term neurological effects. The biochemical changes that occur following nerve agent exposure needs to be elucidated to understand the mechanisms behind their long term neurological effects and to design better therapeutic drugs to block their multiple neurotoxic effects. In the present study, we intend to study the efficacy of antidotes comprising of HI-6 (1-[[[4-(aminocarbonyl)-pyridinio]-methoxy]-methyl]-2-[(hydroxyimino) methyl] pyridinium dichloride), atropine and midazolam on soman induced neurodegeneration and the expression of c-Fos, Calpain, and Bax levels in discrete rat brain areas. Therapeutic regime consisting of HI-6 (50 mg/kg, i.m), atropine (10 mg/kg, i.m) and midazolam (5 mg/kg, i.m) protected animals against soman (2×LD50, s.c) lethality completely at 2 h and 80% at 24 h. HI-6 treatment reactivated soman inhibited plasma and RBC cholinesterase up to 40%. Fluoro-Jade B (FJ-B) staining of neurodegenerative neurons showed that soman induced significant necrotic neuronal cell death, which was reduced by this antidotal treatment. Soman increased the expression of neuronal proteins including c-Fos, Bax and Calpain levels in the hippocampus, cerebral cortex and cerebellum regions of the brain. This therapeutic regime also reduced the soman induced Bax, Calpain expression levels to near control levels in the different brain regions studied, except a mild induction of c-Fos expression in the hippocampus. Rats that received antidotal treatment after soman exposure were protected from mortality and showed reduction in the soman induced expression of c-Fos, Bax and Calpain and necrosis. Results highlight the need for timely administration of better antidotes than standard therapy in order to prevent the molecular and biochemical changes and

  12. Graphene oxide/MnO{sub 2} nanocomposite as destructive adsorbent of nerve-agent simulants in aqueous media

    Energy Technology Data Exchange (ETDEWEB)

    Šťastný, Martin, E-mail: stastny@iic.cas.cz [Materials Chemistry Department, Institute of Inorganic Chemistry AS CR v.v.i., 25068 Husinec-Řež (Czech Republic); Faculty of the Environment, J.E. Purkyně University in Ústí nad Labem, Králova Výšina 7, 400 96 Ústí nad Labem (Czech Republic); Tolasz, Jakub; Štengl, Václav; Henych, Jiří [Materials Chemistry Department, Institute of Inorganic Chemistry AS CR v.v.i., 25068 Husinec-Řež (Czech Republic); Žižka, David [Faculty of the Environment, J.E. Purkyně University in Ústí nad Labem, Králova Výšina 7, 400 96 Ústí nad Labem (Czech Republic)

    2017-08-01

    Highlights: • Nanocomposite graphene oxide-birnessite-type MnO{sub 2} was synthesized by thermal hydrolysis. • New destructive sorbent for safe degradation of nerve-agent simulants. • 95% degradation activity for DMMP and TEP. - Abstract: Graphene oxide/MnO{sub 2} nanocomposite was prepared by thermal hydrolysis of potassium permanganate (KMnO{sub 4}) and 2-chloroacetamide aqueous solutions with graphene oxide (GO) suspension. The synthesized samples were characterized by specific surface area (BET) and porosity determination (BJH), X-ray Diffraction (XRD) and high-resolution electron microscopes (HRSEM, HRTEM). These nanocomposites were used in an experimental evaluation of their adsorption activity with nerve agent simulants dimethyl methyl phosphonate (DMMP) and triethyl phosphate (TEP) in aqueous media. The nanocomposites exhibited enhanced adsorptive degradation ability compared to pure manganese oxide (MnO{sub 2}) and GO. The GO amount in the nanocomposites affected their degradation activity substantially. The best adsorption efficiency was observed for samples with moderate GO amount. Three methods were used to observe the mechanism of the nerve-agent simulants deactivation: Gas chromatography with mass spectrometry (GC–MS), High-Performance Liquid Chromatography (HPLC) and in situ Infrared spectroscopy (FTIR). It was shown that the hydrolysis on the surface of prepared nanocomposites yields volatile primary alcohols (methanol and ethanol) as the main hydrolysis products.

  13. Gallic acid and exercise training improve motor function, nerve conduction velocity but not pain sense reflex after experimental sciatic nerve crush in male rats.

    Science.gov (United States)

    Hajimoradi, Maryam; Fazilati, Mohammad; Gharib-Naseri, Mohammad Kazem; Sarkaki, Alireza

    2015-01-01

    The aim of present study was to evaluate the effects of oral administration of gallic acid (GA) for 21 days alone and in combination with exercise on nerve conduction velocity and sensory and motor functions in rats with sciatic nerve crush. Seventy adult male Wistar rats (250-300 g) were divided randomly into 7 groups with 10 in each: 1) Control (Cont), 2) Crushed + Vehicle (Cr +Veh), 3-5) Crushed + gallic acid (Cr+GA) (50, 100, and 200 mg/kg/2 mL, orally), 6) Crushed + exercise (Cr+Exe), and 7) Crushed + exercise + effective dose of gallic acid (Cr+Exe +GA200) for 21 days. In order to establish an animal model of sciatic nerve crush, equivalent to 7 kg of force pressed on 2-3 mm of sciatic nerve for 30 s, three times with 30 s intervals. Pain sense reflex in hot plate, motor coordination in rotarod, and sciatic nerve conduction velocity (SNCV) in all groups were tested. Data were analyzed using one-way ANOVA followed by Tukey's post hoc test and preflex latency was not changed in treated groups. Motor coordination and SNCV were improved in groups Cr+GA200 and Cr+Exe + GA200 (p<0.05, p<0.01 vs. Cr+Veh). GA, dose-dependently, may have therapeutic potential to improve the peripheral nerve degeneration, which is most likely related, at least in part, to its antioxidant and therapeutic properties.

  14. Nanoparticle-Based Electrochemical Immunosensor for the Detection of Phosphorylated Acetylcholinesterase: An Exposure Biomarker of Organophosphate Pesticides and Nerve AgentsOrganophosphate Pesticides and Nerve Agents

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong; Wang, Jun; Barry, Richard C.; Petersen, Catherine E.; Timchalk, Charles; Gassman, Paul L.; Lin, Yuehe

    2008-11-01

    A nanoparticle-based electrochemical immunosensor has been developed for the detection of phosphorylated acetylcholinesterase (AChE) adducts, which is a potential exposure biomarker for organophosphate pesticides (OP) and chemical warfare nerve agent exposures. Zirconia nanoparticles (ZrO2 NPs) were used as selective sorbents to capture the phosphorylated AChE adduct, and quantum dots (ZnS@CdS, QDs) were used as tags to label monoclonal anti-AChE antibody to track the immunorecognition events. The sandwich-like immunoreactions were performed among the ZrO2 NPs, which were pre-coated on a screen printed electrode (SPE) by electrodeposition, phosphorylated AChE and QD-anti-AChE. The captured QD tags were determined on the SPE by electrochemical stripping analysis of its metallic component (cadmium) after an acid-dissolution step. Paraoxon was used as a model OP insecticide to prepare the phosphorylated AChE adduct to demonstrate the proof of principle for this sensor technology. The paraoxon-AChE adduct was characterized by Fourier Transform Infrared Spectrum, and the binding affinity of anti-AChE to the paraoxon-AChE was validated with an enzyme-linked immunosorbent assay. The parameters (e.g., amount of ZrO2 NP, QD-anti-AChE concentration,) that govern the electrochemical response of immunosensors were optimized. The voltammetric response of the immunosensor is highly linear over the range of 10 pM to 4 nM paraoxon-AChE, and the limit of detection is estimated to be 8 pM. This new nanoparticle-based electrochemical immunosensor thus provides a sensitive and quantitative tool for biomonitoring exposure to OP pesticides and nerve agents.

  15. Prospective of 68Ga Radionuclide Contribution to the Development of Imaging Agents for Infection and Inflammation

    Science.gov (United States)

    2018-01-01

    During the last decade, the utilization of 68Ga for the development of imaging agents has increased considerably with the leading position in the oncology. The imaging of infection and inflammation is lagging despite strong unmet medical needs. This review presents the potential routes for the development of 68Ga-based agents for the imaging and quantification of infection and inflammation in various diseases and connection of the diagnosis to the treatment for the individualized patient management. PMID:29531507

  16. An Acetylcholinesterase-Based Chronoamperometric Biosensor for Fast and Reliable Assay of Nerve Agents

    Directory of Open Access Journals (Sweden)

    Rene Kizek

    2013-08-01

    Full Text Available The enzyme acetylcholinesterase (AChE is an important part of cholinergic nervous system, where it stops neurotransmission by hydrolysis of the neurotransmitter acetylcholine. It is sensitive to inhibition by organophosphate and carbamate insecticides, some Alzheimer disease drugs, secondary metabolites such as aflatoxins and nerve agents used in chemical warfare. When immobilized on a sensor (physico-chemical transducer, it can be used for assay of these inhibitors. In the experiments described herein, an AChE- based electrochemical biosensor using screen printed electrode systems was prepared. The biosensor was used for assay of nerve agents such as sarin, soman, tabun and VX. The limits of detection achieved in a measuring protocol lasting ten minutes were 7.41 × 10−12 mol/L for sarin, 6.31 × 10−12 mol /L for soman, 6.17 × 10−11 mol/L for tabun, and 2.19 × 10−11 mol/L for VX, respectively. The assay was reliable, with minor interferences caused by the organic solvents ethanol, methanol, isopropanol and acetonitrile. Isopropanol was chosen as suitable medium for processing lipophilic samples.

  17. Preparation of Ga-67 labeled monoclonal antibodies using deferoxamine as a bifunctional chelating agent

    International Nuclear Information System (INIS)

    Endo, K.; Furukawa, T.; Ohmomo, Y.

    1984-01-01

    Ga-67 labeled monoclonal IgG or F(ab')/sub 2/ fragments against α-fetoprotein and β-subunit of human choriogonadotropin (HCG), were prepared using Deferoxamine (DFO) as a bifunctional chelating agent. DFO, a well-known iron chelating agent, was conjugated with monoclonal antibodies (Ab) by a glutaraldehyde two step method and the effect of conjugation on the Ab activities was examined by RIA and Scatchard plot analysis. In both monoclonal Ab preparations, the conjugation reaction was favored as the pH increased. However, Ab-binding activities decreased as the molecular ratios of DFO to Ab increased. Preserved Ab activities were observed when Ab contained DFO per Ab molecule less than 2.1. At a ratio of over 3.3 DFO molecules per Ab, the maximal binding capacity rather than the affinity constant decreased. The inter-molecular cross linkage seemed to be responsible for the deactivation of binding activities. The obtained DFO-Ab conjugates, were then easily labeled with high efficiency and reproducibility and Ga-67 DFO-Ab complexes were highly stable both in vitro and in vivo. Thus, biodistribution of Ga-67 labeled F(ab')/sub 2/ fragments of monoclonal Ab to HCG β-subunit was attempted in nude mice transplanted with HCG-producing human teratocarcinoma. Tumor could be visualized, in spite of relatively high background imaging of liver, kidney and spleen. The use of DFO as a bifunctional chelating agent provided good evidence for its applicability to labeling monoclonal Ab with almost full retention of Ab activities. Further, availability of Ga-68 will make Ga-68 DFO-monoclonal Ab a very useful tool for positron tomography imaging of various tumors

  18. Annual Report 2013-2014: Theoretical Studies of Nerve Agents Adsorbed on Surfaces

    Science.gov (United States)

    2014-07-08

    magnesium oxide. Journal of Physical Chemistry B 2004, 108, 5294-5303. 7. Michalkova, A.; Paukku, Y.; Majumdar, D.; Leszczynski, J., Theoretical study...M.; Hyre, A. M., Ultraviolet Raman Spectra and Cross-Sections of the G-series Nerve Agents. Applied Spectroscopy 2008, 62, 1078-1083. 12. DaBell...mol) 24 2.3 Raman and DFT study of pyrocarbonate 2.3.1 In-situ Raman spectroscopic investigation The Li2CO3 and Na2CO3 eutectic mixture (52:48

  19. Best time window for the use of calcium-modulating agents to improve functional recovery in injured peripheral nerves-An experiment in rats.

    Science.gov (United States)

    Yan, Yuhui; Shen, Feng-Yi; Agresti, Michael; Zhang, Lin-Ling; Matloub, Hani S; LoGiudice, John A; Havlik, Robert; Li, Jifeng; Gu, Yu-Dong; Yan, Ji-Geng

    2017-09-01

    Peripheral nerve injury can have a devastating effect on daily life. Calcium concentrations in nerve fibers drastically increase after nerve injury, and this activates downstream processes leading to neuron death. Our previous studies showed that calcium-modulating agents decrease calcium accumulation, which aids in regeneration of injured peripheral nerves; however, the optimal therapeutic window for this application has not yet been identified. In this study, we show that calcium clearance after nerve injury is positively correlated with functional recovery in rats suffering from a crushed sciatic nerve injury. After the nerve injury, calcium accumulation increased. Peak volume is from 2 to 8 weeks post injury; calcium accumulation then gradually decreased over the following 24-week period. The compound muscle action potential (CMAP) measurement from the extensor digitorum longus muscle recovered to nearly normal levels in 24 weeks. Simultaneously, real-time polymerase chain reaction results showed that upregulation of calcium-ATPase (a membrane protein that transports calcium out of nerve fibers) mRNA peaked at 12 weeks. These results suggest that without intervention, the peak in calcium-ATPase mRNA expression in the injured nerve occurs after the peak in calcium accumulation, and CMAP recovery continues beyond 24 weeks. Immediately using calcium-modulating agents after crushed nerve injury improved functional recovery. These studies suggest that a crucial time frame in which to initiate effective clinical approaches to accelerate calcium clearance and nerve regeneration would be prior to 2 weeks post injury. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  20. Transcriptional responses of the nerve agent-sensitive brain regions amygdala, hippocampus, piriform cortex, septum, and thalamus following exposure to the organophosphonate anticholinesterase sarin

    Directory of Open Access Journals (Sweden)

    Meyerhoff James L

    2011-07-01

    Full Text Available Abstract Background Although the acute toxicity of organophosphorus nerve agents is known to result from acetylcholinesterase inhibition, the molecular mechanisms involved in the development of neuropathology following nerve agent-induced seizure are not well understood. To help determine these pathways, we previously used microarray analysis to identify gene expression changes in the rat piriform cortex, a region of the rat brain sensitive to nerve agent exposure, over a 24-h time period following sarin-induced seizure. We found significant differences in gene expression profiles and identified secondary responses that potentially lead to brain injury and cell death. To advance our understanding of the molecular mechanisms involved in sarin-induced toxicity, we analyzed gene expression changes in four other areas of the rat brain known to be affected by nerve agent-induced seizure (amygdala, hippocampus, septum, and thalamus. Methods We compared the transcriptional response of these four brain regions to sarin-induced seizure with the response previously characterized in the piriform cortex. In this study, rats were challenged with 1.0 × LD50 sarin and subsequently treated with atropine sulfate, 2-pyridine aldoxime methylchloride, and diazepam. The four brain regions were collected at 0.25, 1, 3, 6, and 24 h after seizure onset, and total RNA was processed for microarray analysis. Results Principal component analysis identified brain region and time following seizure onset as major sources of variability within the dataset. Analysis of variance identified genes significantly changed following sarin-induced seizure, and gene ontology analysis identified biological pathways, functions, and networks of genes significantly affected by sarin-induced seizure over the 24-h time course. Many of the molecular functions and pathways identified as being most significant across all of the brain regions were indicative of an inflammatory response. There

  1. AMPEROMETRIC THICK-FILM STRIP ELECTRODES FOR MONITORING ORGANOPHOSPHATE NERVE AGENTS BASED ON IMMOBILIZED ORGANOPHOSPHORUS HYDROLASE. (R823663)

    Science.gov (United States)

    An amperometric biosensor based on the immobilization of organophosphorus hydrolase(OPH) onto screen-printed carbon electrodes is shown useful for the rapid, sensitive, and low-costdetection of organophosphate (OP) nerve agents. The sensor relies upon the sensitive and ra...

  2. Development of 68Ga-labeled mannosylated human serum albumin (MSA) as a lymph node imaging agent for positron emission tomography

    International Nuclear Information System (INIS)

    Choi, Jae Yeon; Jeong, Jae Min; Yoo, Byong Chul; Kim, Kyunggon; Kim, Youngsoo; Yang, Bo Yeun; Lee, Yun-Sang; Lee, Dong Soo; Chung, June-Key; Lee, Myung Chul

    2011-01-01

    Introduction: Although many sentinel lymph node (SLN) imaging agents labeled with 99m Tc have been developed, no positron-emitting agent has been specifically designed for SLN imaging. Furthermore, the development of the beta probe and the requirement for better image resolution have increased the need for a positron-emitting SLN imaging agent. Here, we describe the development of a novel positron-emitting SLN imaging agent labeled with 68 Ga. Methods: A mannosylated human serum albumin (MSA) was synthesized by conjugating α-D-mannopyranosylphenyl isothiocyanate to human serum albumin in sodium carbonate buffer (pH 9.5), and then 2-(p-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid was conjugated to synthesize NOTA-MSA. Numbers of mannose and NOTA units conjugated in NOTA-MSA were determined by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. NOTA-MSA was labeled with 68 Ga at room temperature. The stability of 68 Ga-NOTA-MSA was checked in labeling medium at room temperature and in human serum at 37 o C. Biodistribution in normal ICR mice was investigated after tail vein injection, and micro-positron emission tomography (PET) images were obtained after injecting 68 Ga-NOTA-MSA into a tail vein or a footpad. Results: The numbers of conjugated α-D-mannopyranosylphenyl isothiocyanate and 2-(p-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid units in NOTA-MSA were 10.6 and 6.6, respectively. The labeling efficiency of 68 Ga-NOTA-MSA was greater than 99% at room temperature, and its stability was greater than 99% at 4 h. Biodistribution and micro-PET studies of 68 Ga-NOTA-MSA showed high liver and spleen uptakes after intravenous injection. 68 Ga-NOTA-MSA injected into a footpad rapidly migrated to the lymph node. Conclusions: 68 Ga-NOTA-MSA was successfully developed as a novel SLN imaging agent for PET. NOTA-MSA is easily labeled at high efficiency, and subcutaneously administered 68 Ga-NOTA-MSA was

  3. Evaluation of Ga-DOTA-(D-Asp)n as bone imaging agents: D-aspartic acid peptides as carriers to bone.

    Science.gov (United States)

    Ogawa, Kazuma; Ishizaki, Atsushi; Takai, Kenichiro; Kitamura, Yoji; Makino, Akira; Kozaka, Takashi; Kiyono, Yasushi; Shiba, Kazuhiro; Odani, Akira

    2017-10-25

    67 Ga-DOTA-(L-Asp) 11 and 67 Ga-DOTA-(L-Asp) 14 , which have been developed as bone imaging agents, showed a high accumulation in bone and a rapid blood clearance in mice. However, peptides composed of D-amino acids are more stable in vivo than those composed of their L-equivalents. In this study, 67 Ga-DOTA-(D-Asp) n (n = 2, 5, 8, 11, or 14) were synthesized using the Fmoc-based solid-phase methodology and evaluated. In hydroxyapatite binding assay, binding of 67 Ga-DOTA-(D-Asp) n tended to increase with increasing length of the amino acid chain. 67 Ga-DOTA-(D-Asp) 11 and 67 Ga-DOTA-(D-Asp) 14 caused a high accumulation of radioactivity in the bones of the mice. However, the results for 67 Ga-DOTA-(D-Asp) n and 67 Ga-DOTA-(L-Asp) n were comparable. In urine analyses, the proportion of intact complex after injection of 67 Ga-DOTA-(D-Asp) 14 was significantly higher than that of 67 Ga-DOTA-(L-Asp) 14 . Although 67 Ga-DOTA-(D-Asp) 14 was more stable than 67 Ga-DOTA-(L-Asp) 14 , the properties of 67 Ga-DOTA-(D-Asp) n and 67 Ga-DOTA-(L-Asp) n as bone imaging agents may be comparable.

  4. Subacute Low Dose Nerve Agent Exposure Causes DNA Fragmentation in Guinea Pig Leukocytes

    Science.gov (United States)

    2005-10-01

    1 SUBACUTE LOW DOSE NERVE AGENT EXPOSURE CAUSES DNA FRAGMENTATION IN GUINEA PIG LEUKOCYTES. Jitendra R. Dave1, John R. Moffett1, Sally M...DNA fragmentation in blood leukocytes from guinea pigs by ‘Comet’ assay after exposure to soman at doses ranging from 0.1LD50 to 0.4 LD50, once per...computer. Data obtained for exposure to soman demonstrated significant increases in DNA fragmentation in circulating leukocytes in CWNA treated guinea pigs as

  5. The utility of three-dimensional optical projection tomography in nerve injection injury imaging

    Czech Academy of Sciences Publication Activity Database

    Cvetko, E.; Čapek, Martin; Damjanovska, M.; Reina, M. A.; Eržen, I.; Stopar-Pintarič, T.

    2015-01-01

    Roč. 70, č. 8 (2015), s. 939-947 ISSN 0003-2409 R&D Projects: GA ČR(CZ) GA13-12412S; GA MŠk(CZ) LH13028 Institutional support: RVO:67985823 Keywords : optical projection tomography * 3D nerve visualization * nerve disruption Subject RIV: EA - Cell Biology Impact factor: 3.794, year: 2015

  6. Peripheral site ligand conjugation to a non-quaternary oxime enhances reactivation of nerve agent-inhibited human acetylcholinesterase

    NARCIS (Netherlands)

    Koning, M.C. de; Grol, M. van; Noort, D.

    2011-01-01

    Commonly employed pyridinium-oxime (charged) reactivators of nerve agent inhibited acetylcholinesterase (AChE) do not readily pass the blood brain barrier (BBB) because of the presence of charge(s). Conversely, non-ionic oxime reactivators often suffer from a lack of reactivating potency due to a

  7. An in vitro and in vivo evaluation of the efficacy of recombinant human liver prolidase as a catalytic bioscavenger of chemical warfare nerve agents.

    Science.gov (United States)

    Rezk, Peter E; Zdenka, Pierre; Sabnekar, Praveena; Kajih, Takwen; Mata, David G; Wrobel, Chester; Cerasoli, Douglas M; Chilukuri, Nageswararao

    2015-01-01

    In this study, we determined the ability of recombinant human liver prolidase to hydrolyze nerve agents in vitro and its ability to afford protection in vivo in mice. Using adenovirus containing the human liver prolidase gene, the enzyme was over expressed by 200- to 300-fold in mouse liver and purified to homogeneity by affinity and gel filtration chromatography. The purified enzyme hydrolyzed sarin, cyclosarin and soman with varying rates of hydrolysis. The most efficient hydrolysis was with sarin, followed by soman and by cyclosarin {apparent kcat/Km [(1.9 ± 0.3), (1.7 ± 0.2), and (0.45 ± 0.04)] × 10(5 )M(-1 )min(-1), respectively}; VX and tabun were not hydrolyzed by the recombinant enzyme. The enzyme hydrolyzed P (+) isomers faster than the P (-) isomers. The ability of recombinant human liver prolidase to afford 24 hour survival against a cumulative dose of 2 × LD50 of each nerve agent was investigated in mice. Compared to mice injected with a control virus, mice injected with the prolidase expressing virus contained (29 ± 7)-fold higher levels of the enzyme in their blood on day 5. Challenging these mice with two consecutive 1 × LD50 doses of sarin, cyclosarin, and soman resulted in the death of all animals within 5 to 8 min from nerve agent toxicity. In contrast, mice injected with the adenovirus expressing mouse butyrylcholinesterase, an enzyme which is known to afford protection in vivo, survived multiple 1 × LD50 challenges of these nerve agents and displayed no signs of toxicity. These results suggest that, while prolidase can hydrolyze certain G-type nerve agents in vitro, the enzyme does not offer 24 hour protection against a cumulative dose of 2 × LD50 of G-agents in mice in vivo.

  8. A highly stable minimally processed plant-derived recombinant acetylcholinesterase for nerve agent detection in adverse conditions.

    Science.gov (United States)

    Rosenberg, Yvonne J; Walker, Jeremy; Jiang, Xiaoming; Donahue, Scott; Robosky, Jason; Sack, Markus; Lees, Jonathan; Urban, Lori

    2015-08-13

    Although recent innovations in transient plant systems have enabled gram quantities of proteins in 1-2 weeks, very few have been translated into applications due to technical challenges and high downstream processing costs. Here we report high-level production, using a Nicotiana benthamiana/p19 system, of an engineered recombinant human acetylcholinesterase (rAChE) that is highly stable in a minimally processed leaf extract. Lyophylized clarified extracts withstand prolonged storage at 70 °C and, upon reconstitution, can be used in several devices to detect organophosphate (OP) nerve agents and pesticides on surfaces ranging from 0 °C to 50 °C. The recent use of sarin in Syria highlights the urgent need for nerve agent detection and countermeasures necessary for preparedness and emergency responses. Bypassing cumbersome and expensive downstream processes has enabled us to fully exploit the speed, low cost and scalability of transient production systems resulting in the first successful implementation of plant-produced rAChE into a commercial biotechnology product.

  9. Gallic acid and exercise training improve motor function, nerve conduction velocity but not pain sense reflex after experimental sciatic nerve crush in male rats

    Directory of Open Access Journals (Sweden)

    Maryam Hajimoradi

    2015-06-01

    Full Text Available Objective: The aim of present study was to evaluate the effects of oral administration of gallic acid (GA for 21 days alone and in combination with exercise on nerve conduction velocity and sensory and motor functions in rats with sciatic nerve crush. Materials and Methods: Seventy adult male Wistar rats (250-300 g were divided randomly into 7 groups with 10 in each: 1 Control (Cont, 2 Crushed + Vehicle (Cr +Veh, 3-5 Crushed + gallic acid (Cr+GA (50, 100, and 200 mg/kg/2 mL, orally, 6 Crushed + exercise (Cr+Exe, and 7 Crushed + exercise + effective dose of gallic acid (Cr+Exe +GA200 for 21 days. In order to establish an animal model of sciatic nerve crush, equivalent to 7 kg of force pressed on 2-3 mm of sciatic nerve for 30 s, three times with 30 s intervals. Pain sense reflex in hot plate, motor coordination in rotarod, and sciatic nerve conduction velocity (SNCV in all groups were tested. Data were analyzed using one-way ANOVA followed by Tukey’s post hoc test and pResults: Pain threshold was increased significantly in untreated crushed rats while motor function and SNCV were decreased in all groups with nerve crush (p

  10. Studies in rats on octreotide labelled with Ga-67: A potential radiopharmaceutical agent for the treatment of somatostatin receptor-positive tumours

    International Nuclear Information System (INIS)

    Lazniekova, A.; Laznieek, M.; Trejtnar, F.; Maecke, H.R.

    2001-01-01

    The paper presents the preparation, biodistribution and analysis of elimination mechanisms of 67 Ga-[DFO]-octreotide in rats. For labelling of the ligand with 67 Ga, desferrioxamine B (DFO) coupled to octreotide via the succinyl linker has been shown to form a stable chelating agent for binding of 67 Ga. The radiopharmaceutical was prepared by direct chelating of 67 Ga 3+ with [DFO]-octreotide in a slightly acidic reaction medium with high radiochemical purity. Pharmacokinetics of 67 Ga-[DFO]-octreotide of radioactivity in rats has shown relatively rapid elimination of the compound from the body with a long-term retention in the kidney and organs with high somatostatin receptor density. The agent was eliminated mostly by urine predominantly by the mechanism of glomerular filtration. (author)

  11. Smart Agents and Sentiment in the Heterogeneous Agent Model

    Czech Academy of Sciences Publication Activity Database

    Vácha, Lukáš; Baruník, Jozef; Vošvrda, Miloslav

    2009-01-01

    Roč. 18, č. 3 (2009), s. 209-219 ISSN 1210-0455 R&D Projects: GA MŠk(CZ) LC06075; GA ČR GP402/08/P207; GA ČR(CZ) GA402/09/0965 Institutional research plan: CEZ:AV0Z10750506 Keywords : heterogeneous agent model * market structure * smart traders * Hurst exponent Subject RIV: AH - Economics http://library.utia.cas.cz/separaty/2009/E/vacha- smart agent s and sentiment in the heterogeneous agent model.pdf

  12. The Application of the Fluoride Reactivation Process to the Detection of Sarin and Soman Nerve Agent Exposures in Biological Samples

    National Research Council Canada - National Science Library

    Adams, T. K; Capacio, B. R; Smith, J. R; Whalley, C. E; Korte, W. D

    2004-01-01

    The fluoride reactivation process was evaluated for measuring the level of sarin or soman nerve agents reactivated from substrates in plasma and tissue from in vivo exposed guinea pigs (Cava porcellus...

  13. Flexible carbon nanotube sensors for nerve agent simulants

    Energy Technology Data Exchange (ETDEWEB)

    Cattanach, Kyle; Kulkarni, Rashmi D; Kozlov, Mikhail; Manohar, Sanjeev K [Alan G MacDiarmid Center for Innovation, Department of Chemistry, University of Texas at Dallas, Richardson 75083-0688 (United States)

    2006-08-28

    Chemiresistor-based vapour sensors made from network films of single-walled carbon nanotube (SWNT) bundles on flexible plastic substrates (polyethylene terephthalate, PET) can be used to detect chemical warfare agent simulants for the nerve agents Sarin (diisopropyl methylphosphonate, DIMP) and Soman (dimethyl methylphosphonate, DMMP). Large, reproducible resistance changes (75-150%), are observed upon exposure to DIMP or DMMP vapours, and concentrations as low as 25 ppm can be detected. Robust sensor response to simulant vapours is observed even in the presence of large equilibrium concentrations of interferent vapours commonly found in battle-space environments, such as hexane, xylene and water (10 000 ppm each), suggesting that both DIMP and DMMP vapours are capable of selectively displacing other vapours from the walls of the SWNTs. Response to these interferent vapours can be effectively filtered out by using a 2 {mu}m thick barrier film of the chemoselective polymer polyisobutylene (PIB) on the SWNT surface. These network films are composed of a 1-2 {mu}m thick non-woven mesh of SWNT bundles (15-30 nm diameter), whose sensor response is qualitatively and quantitatively different from previous studies on individual SWNTs, or a network of individual SWNTs, suggesting that vapour sorption at interbundle sites could be playing an important role. This study also shows that the line patterning method used in device fabrication to obtain any desired pattern of films of SWNTs on flexible substrates can be used to rapidly screen simulants at high concentrations before developing more complicated sensor systems.

  14. Development of {sup 68}Ga-labeled mannosylated human serum albumin (MSA) as a lymph node imaging agent for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae Yeon [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul (Korea, Republic of); Department of Radiation Applied Life Sciences, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jeong, Jae Min, E-mail: jmjng@snu.ac.k [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul (Korea, Republic of); Department of Radiation Applied Life Sciences, Seoul National University College of Medicine, Seoul (Korea, Republic of); Yoo, Byong Chul [Research Institute, National Cancer Center, Goyang, Gyeonggi (Korea, Republic of); Kim, Kyunggon; Kim, Youngsoo [Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul (Korea, Republic of); Yang, Bo Yeun; Lee, Yun-Sang; Lee, Dong Soo [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Department of Radiation Applied Life Sciences, Seoul National University College of Medicine, Seoul (Korea, Republic of); Chung, June-Key [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul (Korea, Republic of); Department of Radiation Applied Life Sciences, Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Myung Chul [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2011-04-15

    Introduction: Although many sentinel lymph node (SLN) imaging agents labeled with {sup 99m}Tc have been developed, no positron-emitting agent has been specifically designed for SLN imaging. Furthermore, the development of the beta probe and the requirement for better image resolution have increased the need for a positron-emitting SLN imaging agent. Here, we describe the development of a novel positron-emitting SLN imaging agent labeled with {sup 68}Ga. Methods: A mannosylated human serum albumin (MSA) was synthesized by conjugating {alpha}-D-mannopyranosylphenyl isothiocyanate to human serum albumin in sodium carbonate buffer (pH 9.5), and then 2-(p-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid was conjugated to synthesize NOTA-MSA. Numbers of mannose and NOTA units conjugated in NOTA-MSA were determined by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. NOTA-MSA was labeled with {sup 68}Ga at room temperature. The stability of {sup 68}Ga-NOTA-MSA was checked in labeling medium at room temperature and in human serum at 37{sup o}C. Biodistribution in normal ICR mice was investigated after tail vein injection, and micro-positron emission tomography (PET) images were obtained after injecting {sup 68}Ga-NOTA-MSA into a tail vein or a footpad. Results: The numbers of conjugated {alpha}-D-mannopyranosylphenyl isothiocyanate and 2-(p-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid units in NOTA-MSA were 10.6 and 6.6, respectively. The labeling efficiency of {sup 68}Ga-NOTA-MSA was greater than 99% at room temperature, and its stability was greater than 99% at 4 h. Biodistribution and micro-PET studies of {sup 68}Ga-NOTA-MSA showed high liver and spleen uptakes after intravenous injection. {sup 68}Ga-NOTA-MSA injected into a footpad rapidly migrated to the lymph node. Conclusions: {sup 68}Ga-NOTA-MSA was successfully developed as a novel SLN imaging agent for PET. NOTA-MSA is easily labeled at high

  15. The Neuroprotective Benefits of Central Adenosine Receptor Stimulation in a Soman Nerve Agent Rat Model

    Science.gov (United States)

    2014-04-01

    where treatment is delayed and nerve agent-induced status epilepticus develops. New therapeutic targets are required to improve survivability and...Exp Ther 304(3): 1307-1313. Compton, J. R. (2004). Adenosine Receptor Agonist Pd 81,723 Protects Against Seizure/ Status Epilepticus and...Dragunow (1994). " Status epilepticus may be caused by loss of adenosine anticonvulsant mechanisms." Neuroscience 58(2): 245-261. Youssef, A. F. and B. W

  16. Measurements of some basic constants of 68Ga(BAT-TECH) as an imaging agent

    International Nuclear Information System (INIS)

    Chen Huawei; Liu Boli

    1994-01-01

    The kinetic properties of a new myocardial imaging agent 68 Ga(BAT-TECH) are investigated and its thermodynamic constants are measured. The results are as follows: Citrate→BAT-TECH exchange reaction order is second-order; reaction rate k = 0.50 l/mol·s; activation energy E a = 56.6 kJ/mol; the stability constant of 68 Ga(BAT-TECH) lgβ = 14.9; the acid dissociation constants of BAT-TECH pK 1 = 4.62, pK 2 = 7.68, pK-3 = 8.68, pK 4 = 11.2

  17. The role of the oximes HI-6 and HS-6 inside human acetylcholinesterase inhibited with nerve agents: a computational study.

    Science.gov (United States)

    Cuya, Teobaldo; Gonçalves, Arlan da Silva; da Silva, Jorge Alberto Valle; Ramalho, Teodorico C; Kuca, Kamil; C C França, Tanos

    2017-10-27

    The oximes 4-carbamoyl-1-[({2-[(E)-(hydroxyimino) methyl] pyridinium-1-yl} methoxy) methyl] pyridinium (known as HI-6) and 3-carbamoyl-1-[({2-[(E)-(hydroxyimino) methyl] pyridinium-1-yl} methoxy) methyl] pyridinium (known as HS-6) are isomers differing from each other only by the position of the carbamoyl group on the pyridine ring. However, this slight difference was verified to be responsible for big differences in the percentual of reactivation of acetylcholinesterase (AChE) inhibited by the nerve agents tabun, sarin, cyclosarin, and VX. In order to try to find out the reason for this, a computational study involving molecular docking, molecular dynamics, and binding energies calculations, was performed on the binding modes of HI-6 and HS-6 on human AChE (HssAChE) inhibited by those nerve agents.

  18. Characterizing biological variability in livestock blood cholinesterase activity for biomonitoring organophosphate nerve agent exposure

    Energy Technology Data Exchange (ETDEWEB)

    Halbrook, R.S.; Shugart, L.R.; Watson, A.P.; Munro, N.B.; Linnabary, R.D. (Environmental Sciences Division, Oak Ridge National Laboratory, TN (United States))

    1992-09-01

    A biomonitoring protocol, using blood cholinesterase (ChE) activity in livestock as a monitor of potential organophosphate nerve agent exposure during the planned destruction of US unitary chemical warfare agent stockpiles, is described. The experimental design included analysis of blood ChE activity in individual healthy sheep, horses, and dairy and beef cattle during a 10- to 12-month period. Castrated and sexually intact males, pregnant and lactating females, and adult and immature animals were examined through at least one reproductive cycle. The same animals were used throughout the period of observation and were not exposed to ChE-inhibiting organophosphate or carbamate compounds. A framework for an effective biomonitoring protocol within a monitoring area includes establishing individual baseline blood ChE activity for a sentinel group of 6 animals on the bases of blood samples collected over a 6-month period, monthly collection of blood samples for ChE-activity determination during monitoring, and selection of adult animals as sentinels. Exposure to ChE-inhibiting compounds would be suspected when all blood ChE activity of all animals within the sentinel group are decreased greater than 20% from their own baseline value. Sentinel species selection is primarily a logistical and operational concern; however, sheep appear to be the species of choice because within-individual baseline ChE activity and among age and gender group ChE activity in sheep had the least variability, compared with data from other species. This protocol provides an effective and efficient means for detecting abnormal depressions in blood ChE activity in livestock and can serve as a valuable indicator of the extent of actual plume movement and/or deposition in the event of organophosphate nerve agent release.

  19. Preparation and evaluation of 68Ga-ECC as a PET renal imaging agent

    International Nuclear Information System (INIS)

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro; Geramifar, Patham; Beiki, Davood

    2015-01-01

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop 68 Ga-ethylenecysteamine cysteine ( 68 Ga-ECC). Ga-ECC was prepared using generator-based 68 GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). 68 Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV max ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous 99m Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time

  20. Evaluation of Ga-DOTA-(D-Asp)n as bone imaging agents: D-aspartic acid peptides as carriers to bone

    OpenAIRE

    Ogawa, Kazuma; Ishizaki, Atsushi; Takai, Kenichiro; Kitamura, Yoji; Makino, Akira; Kozaka, Takashi; Kiyono, Yasushi; Shiba, Kazuhiro; Odani, Akira

    2017-01-01

    67Ga-DOTA-(L-Asp)11 and 67Ga-DOTA-(L-Asp)14, which have been developed as bone imaging agents, showed a high accumulation in bone and a rapid blood clearance in mice. However, peptides composed of D-amino acids are more stable in vivo than those composed of their L-equivalents. In this study, 67Ga-DOTA-(D-Asp)n (n = 2, 5, 8, 11, or 14) were synthesized using the Fmoc-based solid-phase methodology and evaluated. In hydroxyapatite binding assay, binding of 67Ga-DOTA-(D-Asp)n tended to increase ...

  1. Plant-derived human butyrylcholinesterase, but not an organophosphorous-compound hydrolyzing variant thereof, protects rodents against nerve agents

    OpenAIRE

    Geyer, Brian C.; Kannan, Latha; Garnaud, Pierre-Emmanuel; Broomfield, Clarence A.; Cadieux, C. Linn; Cherni, Irene; Hodgins, Sean M.; Kasten, Shane A.; Kelley, Karli; Kilbourne, Jacquelyn; Oliver, Zeke P.; Otto, Tamara C.; Puffenberger, Ian; Reeves, Tony E.; Robbins, Neil

    2010-01-01

    The concept of using cholinesterase bioscavengers for prophylaxis against organophosphorous nerve agents and pesticides has progressed from the bench to clinical trial. However, the supply of the native human proteins is either limited (e.g., plasma-derived butyrylcholinesterase and erythrocytic acetylcholinesterase) or nonexisting (synaptic acetylcholinesterase). Here we identify a unique form of recombinant human butyrylcholinesterase that mimics the native enzyme assembly into tetramers; t...

  2. Tetrafluorophenolate of HBED-CC: a versatile conjugation agent for 68Ga-labeled small recombinant antibodies

    International Nuclear Information System (INIS)

    Eder, Matthias; Waengler, Bjoern; Eisenhut, Michael; Knackmuss, Stefan; LeGall, Fabrice; Little, Melvyn; Haberkorn, Uwe; Mier, Walter

    2008-01-01

    The success of 68 Ga-labeled peptides for positron emission tomography of neuroendocrine tumors is mainly depending on the complex chemistry of this radioisotope. 1,4,7,10-Tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), the chelator of choice has however limitations if its application is expanded to heat-sensitive proteins. Recombinant antibodies like single chain Fv or diabodies belong to this class of proteins. They are suited to provide imaging contrast despite the short-lived 68 Ga because of their rapid blood clearances and nanomolar affinities. The heterobifunctional agent N,N'-bis[2-hydroxy-5-(carboxyethyl)benzyl]ethylenediamine-N,N'-diacetic acid (HBED-CC) was chosen as an alternative ligand because this agent is complexing [ 68 Ga]Ga 3+ much faster than DOTA at ambient temperatures. A versatile technology for HBED-CC conjugation of proteins and 68 Ga-labeling has been developed. This included HBED-CC-tetrafluorophenol (TFP) ester synthesis, coupling to the antibody at various pH and complexation reactions performed in 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) buffer under different conditions. The synthesis of the monoreactive 2,3,5,6-tetrafluorophenolate of HBED-CC at a carboxyl group not participating in complex formation used [Fe(HBED-CC)] - for ester formation. The removal of Fe 3+ from purified (HBED-CC)TFP ester was achieved with RP 18 cartridge technology. The conjugation chemistry was performed with mAb425 which binds to the epidermal growth factor receptor (EGFR). This protein was used for optimizing purposes only. The influence of complexation parameters like temperature, pH, reaction time, and HBED-CC/antibody ratio on the biological activity of this model antibody was investigated. Furthermore, the outcome of this labeling procedure on the biological activity of a recombinant diabody (50 kDa) was studied. It is known that small HBED-CC/antibody ratios are prerequisites for minimal interference of labels with antigen

  3. Preparation and evaluation of {sup 68}Ga-ECC as a PET renal imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro [Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Geramifar, Patham; Beiki, Davood [Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2015-09-15

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop {sup 68}Ga-ethylenecysteamine cysteine ({sup 68}Ga-ECC). Ga-ECC was prepared using generator-based {sup 68}GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). {sup 68}Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV{sub max} ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous {sup 99m}Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time.

  4. Large-area irradiated low-level laser effect in a biodegradable nerve guide conduit on neural regeneration of peripheral nerve injury in rats.

    Science.gov (United States)

    Shen, Chiung-Chyi; Yang, Yi-Chin; Liu, Bai-Shuan

    2011-08-01

    This study used a biodegradable composite containing genipin-cross-linked gelatin annexed with β-tricalcium phosphate ceramic particles (genipin-gelatin-tricalcium phosphate, GGT), developed in a previous study, as a nerve guide conduit. The aim of this study was to analyse the influence of a large-area irradiated aluminium-gallium-indium phosphide (AlGaInP) diode laser (660 nm) on the neural regeneration of the transected sciatic nerve after bridging the GGT nerve guide conduit in rats. The animals were divided into two groups: group 1 comprised sham-irradiated controls and group 2 rats underwent low-level laser (LLL) therapy. A compact multi-cluster laser system with 20 AlGaInP laser diodes (output power, 50mW) was applied transcutaneously to the injured peripheral nerve immediately after closing the wound, which was repeated daily for 5 min for 21 consecutive days. Eight weeks after implantation, walking track analysis showed a significantly higher sciatic function index (SFI) score (Pguide conduit in rats. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Preclinical Assessment of a 68Ga-DOTA-Functionalized Depsipeptide as a Radiodiagnostic Infection Imaging Agent.

    Science.gov (United States)

    Ebenhan, Thomas; Mokaleng, Botshelo Brenda; Venter, Jacobus Daniel; Kruger, Hendrik Gert; Zeevaart, Jan Rijn; Sathekge, Mike

    2017-08-24

    The study assessed a radiolabeled depsipeptide conjugate ( 68 Ga-DOTA-TBIA101) for its potential as an imaging agent targeting infection or infection-associated inflammation. 68 Ga-labeled DOTA-TBIA101 imaging was performed in (NZR1) healthy rabbits; (NZR2) rabbits bearing muscular sterile inflammation and Staphylococcus aureus (SA) infection; and (NZR3) rabbits infected with Mycobacterium tuberculosis (MTB) combined with a subcutaneous scruff infection of SA in the same animal. All animals were imaged using a PET/CT scanner at 5 and 60 min post injection. Images showed elevated accumulation of 68 Ga-DOTA-TBIA101 in the sterile muscular inflammation site (T/NT ratio = 2.6 ± 0.37 (5 min) and 2.8 ± 2.3 (60 min)) and muscles infected with MTB (T/NT ratio = 2.6 ± 0.35 (5 min) and 2.8 ± 0.16 (60 min)). The findings suggest that 68 Ga-DOTA-TBIA101-PET/CT may detect MTB-associated inflammation, although more foundational studies need to be performed to rationalize the diagnostic value of this technique.

  6. Smart Agents and Sentiment in the Heterogeneous Agent Model

    Czech Academy of Sciences Publication Activity Database

    Vácha, Lukáš; Baruník, Jozef; Vošvrda, Miloslav

    -, č. 81 (2010), s. 39-40 ISSN 0926-4981 R&D Projects: GA ČR(CZ) GA402/09/0965; GA ČR GP402/08/P207 Grant - others:GAUK(CZ) GAUK 46108 Institutional research plan: CEZ:AV0Z10750506 Keywords : Smart traders * price movements * smart traders concept Subject RIV: AH - Economics http://library.utia.cas.cz/separaty/2010/E/vacha- smart agent s and sentiment in the heterogeneous agent model.pdf

  7. Prophylaxis and Therapy Against Chemical Agents

    Science.gov (United States)

    2009-11-01

    Hematopoietic Consequences F. Dorandeu 5) pH Dependent Toxicity of Sulphur Mustard In Vitro J. Mikler Nerve Agents / Scavengers 1) Mutagenesis...symptoms such as salivation or shortness of breath and lower level exposures could be rendered inconsequential. B.2 CURRENT THERAPY FOR NERVE AGENT

  8. The oxime pro-2-PAM provides minimal protection against the CNS effects of the nerve agents sarin, cyclosarin, and VX in guinea pigs.

    Science.gov (United States)

    Shih, Tsung-Ming; Guarisco, John A; Myers, Todd M; Kan, Robert K; McDonough, John H

    2011-01-01

    This study examined whether pro-2-PAM, a pro-drug dihydropyridine derivative of the oxime 2-pralidoxime (2-PAM) that can penetrate the brain, could prevent or reverse the central toxic effects of three nerve agents; sarin, cyclosarin, and VX. The first experiment tested whether pro-2-PAM could reactivate guinea pig cholinesterase (ChE) in vivo in central and peripheral tissues inhibited by these nerve agents. Pro-2-PAM produced a dose-dependent reactivation of sarin- or VX-inhibited ChE in both peripheral and brain tissues, but with substantially greater reactivation in peripheral tissues compared to brain. Pro-2-PAM produced 9-25% reactivation of cyclosarin-inhibited ChE in blood, heart, and spinal cord, but no reactivation in brain or muscle tissues. In a second experiment, the ability of pro-2-PAM to block or terminate nerve agent-induced electroencephalographic seizure activity was evaluated. Pro-2-PAM was able to block sarin- or VX-induced seizures (16-33%) over a dose range of 24-32 mg/kg, but was ineffective against cyclosarin-induced seizures. Animals that were protected from seizures showed significantly less weight loss and greater behavioral function 24 h after exposure than those animals that were not protected. Additionally, brains were free from neuropathology when pro-2-PAM prevented seizures. In summary, pro-2-PAM provided modest reactivation of sarin- and VX-inhibited ChE in the brain and periphery, which was reflected by a limited ability to block or terminate seizures elicited by these agents. Pro-2-PAM was able to reactivate blood, heart, and spinal cord ChE inhibited by cyclosarin, but was not effective against cyclosarin-induced seizures.

  9. Advances in toxicology and medical treatment of chemical warfare nerve agents

    Science.gov (United States)

    2012-01-01

    Organophosphorous (OP) Nerve agents (NAs) are known as the deadliest chemical warfare agents. They are divided into two classes of G and V agents. Most of them are liquid at room temperature. NAs chemical structures and mechanisms of actions are similar to OP pesticides, but their toxicities are higher than these compounds. The main mechanism of action is irreversible inhibition of Acetyl Choline Esterase (AChE) resulting in accumulation of toxic levels of acetylcholine (ACh) at the synaptic junctions and thus induces muscarinic and nicotinic receptors stimulation. However, other mechanisms have recently been described. Central nervous system (CNS) depression particularly on respiratory and vasomotor centers may induce respiratory failure and cardiac arrest. Intermediate syndrome after NAs exposure is less common than OP pesticides poisoning. There are four approaches to detect exposure to NAs in biological samples: (I) AChE activity measurement, (II) Determination of hydrolysis products in plasma and urine, (III) Fluoride reactivation of phosphylated binding sites and (IV) Mass spectrometric determination of cholinesterase adducts. The clinical manifestations are similar to OP pesticides poisoning, but with more severity and fatalities. The management should be started as soon as possible. The victims should immediately be removed from the field and treatment is commenced with auto-injector antidotes (atropine and oximes) such as MARK I kit. A 0.5% hypochlorite solution as well as novel products like M291 Resin kit, G117H and Phosphotriesterase isolated from soil bacterias, are now available for decontamination of NAs. Atropine and oximes are the well known antidotes that should be infused as clinically indicated. However, some new adjuvant and additional treatment such as magnesium sulfate, sodium bicarbonate, gacyclidine, benactyzine, tezampanel, hemoperfusion, antioxidants and bioscavengers have recently been used for OP NAs poisoning. PMID:23351280

  10. The Limitations of Diazepam as a Treatment for Nerve Agent-Induced Seizures and Neuropathology in Rats: Comparison with UBP302

    Science.gov (United States)

    2014-11-01

    to nerve agents induces prolonged status epilepticus (SE), causing brain damage or death. Diazepam (DZP) is the cur- rent US Food and Drug... status epilepticus (SE), which are initiated by the excessive stimulation of cholinergic receptors. If immediate death is prevented by adequate...5-yl)ethyl] decahydroisoquinoline-3-carboxylic acid; PBS, phosphate-buffered saline; SE, status epilepticus ; UBP302, (S)-3-(2-carboxybenzyl

  11. Biomaterials for mediation of chemical and biological warfare agents.

    Science.gov (United States)

    Russell, Alan J; Berberich, Jason A; Drevon, Geraldine F; Koepsel, Richard R

    2003-01-01

    Recent events have emphasized the threat from chemical and biological warfare agents. Within the efforts to counter this threat, the biocatalytic destruction and sensing of chemical and biological weapons has become an important area of focus. The specificity and high catalytic rates of biological catalysts make them appropriate for decommissioning nerve agent stockpiles, counteracting nerve agent attacks, and remediation of organophosphate spills. A number of materials have been prepared containing enzymes for the destruction of and protection against organophosphate nerve agents and biological warfare agents. This review discusses the major chemical and biological warfare agents, decontamination methods, and biomaterials that have potential for the preparation of decontamination wipes, gas filters, column packings, protective wear, and self-decontaminating paints and coatings.

  12. Potential use of 68Ga-apo-transferrin as a PET imaging agent for detecting Staphylococcus aureus infection

    International Nuclear Information System (INIS)

    Kumar, Vijay; Boddeti, Dilip K.; Evans, Scott G.; Roesch, Frank; Howman-Giles, Robert

    2011-01-01

    Introduction: 67 Ga citrate has been extensively used to detect infection and inflammation since 1971. However, its clinical utility is compromised due to several limitations. The present project explored whether 68 Ga-apo-transferrin ( 68 Ga-TF), when prepared in vitro, is a useful agent for positron emission tomography (PET) imaging of bacterial infection. Methods: An infection was induced in male Wistar rats by injecting 5x10 5 CFU units of Staphyococcus aureus in the right thigh muscle. 68 Ga-TF was synthesized by mixing 68 GaCl 3 with apo-transferrin (TF, 2 mg) in sodium carbonate (0.1 M, pH 7.0) and incubating at 40 o C for 1 h. Animals were injected with 10-15 MBq of 68 Ga-TF containing approximately 0.2 mg TF and imaged at different time intervals using Siemens Biograph PET-CT. Results: When 68 Ga-TF were injected in the infected rats, the infection lesion was detectable within 20 min post injection. The biodistribution showed the uptake at the lesion increased with time as shown by significantly increased standard uptake values for up to 4 h post injection. There was a considerable decrease in the background activity during the same period of study, giving higher target-to-muscle ratios. Blood pool activity at 3 h post injection was insignificant. 68 GaCl 3 (when not conjugated to TF) did not localize at the infection lesion up to 120 min post injection. Conclusion: The preliminary results suggest that 68 Ga-TF is capable of detecting S. aureus infection in the rat model, within an hour after intravenous injection.

  13. PEGylated superparamagnetic iron oxide nanoparticles labeled with 68Ga as a PET/MRI contrast agent. A biodistribution study

    International Nuclear Information System (INIS)

    Afsaneh Lahooti; Gruttner, Cordula; Parham Geramifar; Hassan Yousefnia

    2017-01-01

    The purpose of this study is to evaluate the biodistribution of polyethylene glycol (PEG) coated superparamagnetic iron oxide nanoparticles radiolabeled with 68 Ga in normal mice after intravenous administration of this probe. Three mice were sacrificed at specific time intervals. The biodistribution data revealed high uptake by liver and spleen (60.62 and 12.65 %ID/g at 120 min post injection for liver and spleen, respectively). The clearance of other organs was fast. These results suggest that 68 Ga-PEG-SPIONs has magnificent capabilities for applying in (PET-MRI) as a theranostic agent for detection of liver and spleen malignancies. (author)

  14. Heterogeneous Agents Model with the Worst Out Algorithm

    Czech Academy of Sciences Publication Activity Database

    Vošvrda, Miloslav; Vácha, Lukáš

    I, č. 1 (2007), s. 54-66 ISSN 1802-4696 R&D Projects: GA MŠk(CZ) LC06075; GA ČR(CZ) GA402/06/0990 Grant - others:GA UK(CZ) 454/2004/A-EK/FSV Institutional research plan: CEZ:AV0Z10750506 Keywords : Efficient Market s Hypothesis * Fractal Market Hypothesis * agents' investment horizons * agents' trading strategies * technical trading rules * heterogeneous agent model with stochastic memory * Worst out Algorithm Subject RIV: AH - Economics

  15. Use of the accelerating rotarod for assessment of motor performance decrement induced by potential anticonvulsant compounds in nerve agent poisoning. (Reannouncement with new availability information)

    Energy Technology Data Exchange (ETDEWEB)

    Capacio, B.R.; Harris, L.W.; Anderson, D.R.; Lennox, W.J.; Gales, V.

    1992-12-31

    The accelerating rotarod was used to assess motor performance decrement in rats after administration of candidate anticonvulsant compounds (acetazolamide, amitriptyline, chlordiazepoxide, diazepan, diazepam-lysine, lorazepam, loprazolam, midazolam, phenobarbital and scopolamine) against nerve agent poisoning. AH compounds were tested as the commercially available injectable preparation except for diazepam-lysine and loprazolam, which are not FDA approved. A peak effect time, as well as a dose to decrease performance time by 50% from control (PDD50), was determined. The calculated PDD50 (micrometer ol/kg) values and peak effect tunes were midazolam, 1.16 at 15 min; loprazolam, 1.17 at 15 min; diazepam-lysine, 4.17 at 30 min; lorazepwn, 4.98 at 15 min; diazepam, 5.27 at 15 min; phenobarbital, 101.49 at 45 min; chlordiazepoxide, 159.21 at 30 min; scopolamine, amitriptyline and acetazolamide did not demonstrate a performance decrement at any of the doses tested. The PDD50 values were compared with doses which have been utilized against nerve agent-induced convulsions or published ED50 values from standard anticonvulsant screening tests (maximal electroshock MES and subcutaneous pentylenetetrazol (scMET)). I serve agents, anticonvulsants, diazepam, accelerating rotarod, motor performance.

  16. Improving the Catalytic Activity of Hyperthermophilic Pyrococcus horikoshii Prolidase for Detoxification of Organophosphorus Nerve Agents over a Broad Range of Temperatures

    Science.gov (United States)

    2011-01-01

    affinity for metal, and increased thermostability compared to P. furiosus prolidase, Pf prol (PF1343). To obtain a better enzyme for OP nerve agent...decontamination and to investigate the structural factors that may influence protein thermostability and thermoactivity, randomly mutated Ph1prol enzymes ...Introduction Pyrococcus horikoshii and Pyrococcus furiosus are both hyper- thermophilic archaea, growing optimally at 98 –100◦C that were isolated from a

  17. Determination of Nerve Agent Metabolites by Ultraviolet Femtosecond Laser Ionization Mass Spectrometry.

    Science.gov (United States)

    Hamachi, Akifumi; Imasaka, Tomoko; Nakamura, Hiroshi; Li, Adan; Imasaka, Totaro

    2017-05-02

    Nerve agent metabolites, i.e., isopropyl methylphosphonic acid (IMPA) and pinacolyl methylphosphonic acid (PMPA), were derivatized by reacting them with 2,3,4,5,6-pentafluorobenzyl bromide (PFBBr) and were determined by mass spectrometry using an ultraviolet femtosecond laser emitting at 267 and 200 nm as the ionization source. The analytes of the derivatized compounds, i.e., IMPA-PFB and PMPA-PFB, contain a large side-chain, and molecular ions are very weak or absent in electron ionization mass spectrometry. The use of ultraviolet femtosecond laser ionization mass spectrometry, however, resulted in the formation of a molecular ion, even for compounds such as these that contain a highly bulky functional group. The signal intensity was larger at 200 nm due to resonance-enhanced two-photon ionization. In contrast, fragmentation was suppressed at 267 nm (nonresonant two-photon ionization) especially for PMPA-PFB, thus resulting in a lower background signal. This favorable result can be explained by the small excess energy in ionization at 267 nm and by the low-frequency vibrational mode of a bulky trimethylpropyl group in PMPA.

  18. Comparison of the lethal effects of chemical warfare nerve agents across multiple ages.

    Science.gov (United States)

    Wright, Linnzi K M; Lee, Robyn B; Vincelli, Nicole M; Whalley, Christopher E; Lumley, Lucille A

    2016-01-22

    Children may be inherently more vulnerable than adults to the lethal effects associated with chemical warfare nerve agent (CWNA) exposure because of their closer proximity to the ground, smaller body mass, higher respiratory rate, increased skin permeability and immature metabolic systems. Unfortunately, there have only been a handful of studies on the effects of CWNA in pediatric animal models, and more research is needed to confirm this hypothesis. Using a stagewise, adaptive dose design, we estimated the 24h median lethal dose for subcutaneous exposure to seven CWNA in both male and female Sprague-Dawley rats at six different developmental times. Perinatal (postnatal day [PND] 7, 14 and 21) and adult (PND 70) rats were more susceptible than pubertal (PND 28 and 42) rats to the lethal effects associated with exposure to tabun, sarin, soman and cyclosarin. Age-related differences in susceptibility were not observed in rats exposed to VM, Russian VX or VX. Published by Elsevier Ireland Ltd.

  19. Development of 68Ga-SCN-DOTA-Capsaicin as an Imaging Agent Targeting Apoptosis and Cell Cycle Arrest in Breast Cancer.

    Science.gov (United States)

    Lee, Jun Young; Lee, Sang-Yeun; Kim, Gun Gyun; Hur, Min Goo; Yang, Seung Dae; Park, Jeong-Hoon; Kim, Sang Wook

    2017-06-01

    68 Ga-labeled capsaicin using a DOTA (1,4,7,10-tetraazocyclododecane-N,N',N″,N'″-tetraacetic acid) derivative [ 68 Ga-SCN-Benzyl(Bn)-DOTA-capsaicin] was studied for the diagnosis of breast cancers, such as MCF-7 and SK-BR-3. The standard compound, 69 Ga-SCN-Bn-DOTA-capsaicin, was also prepared and characterized by spectroscopic analysis. The binding affinity of 68 Ga-SCN-Bn-DOTA-capsaicin was evaluated by using breast cancer cell lines (MCF-7, SK-BR-3) and colon cancer cell (CT-26); the biodistribution was carried out by using MCF-7-bearing nude mice, after which the positron emission tomography (PET) images were obtained at different time intervals (15-120 minutes). 68 Ga-SCN-Bn-DOTA-capsaicin showed a cellular uptake of 0.93% Injected Dose (ID) after 30 minutes of incubation, whereas 68 Ga-SCN-Bn-DOTA showed a lower uptake of 0.25% ID. The tumor-to-blood ID/g% ratios increased and were found to be 0.49, 0.22, and 0.77 for 15, 30, and 60 minutes, respectively. The small-animal PET study showed that the uptake of 68 Ga-SCN-Bn-DOTA-capsaicin was higher in the tumor regions even at 30 minutes after injection. These results suggest that 68 Ga-SCN-Bn-DOTA-capsaicin is a potential targeting agent for PET imaging of MCF-7.

  20. Curcumin promotes nerve regeneration and functional recovery after sciatic nerve crush injury in diabetic rats.

    Science.gov (United States)

    Ma, Junxiong; Yu, Hailong; Liu, Jun; Chen, Yu; Wang, Qi; Xiang, Liangbi

    2016-01-01

    Curcumin is capable of promoting peripheral nerve regeneration in normal condition. However, it is unclear whether its beneficial effect on nerve regeneration still exists under diabetic mellitus. The present study was designed to investigate such a possibility. Diabetes in rats was developed by a single dose of streptozotocin at 50 mg/kg. Immediately after nerve crush injury, the diabetic rats were intraperitoneally administrated daily for 4 weeks with curcumin (50 mg/kg, 100 mg/kg and 300 mg/kg), or normal saline, respectively. The axonal regeneration was investigated by morphometric analysis and retrograde labeling. The functional recovery was evaluated by electrophysiological studies and behavioral analysis. Axonal regeneration and functional recovery was significantly enhanced by curcumin, which were significantly better than those in vehicle saline group. In addition, high doses of curcumin (100 mg/kg and 300 mg/kg) achieved better axonal regeneration and functional recovery than low dose (50 mg/kg). In conclusion, curcumin is capable of promoting nerve regeneration after sciatic nerve crush injury in diabetes mellitus, highlighting its therapeutic values as a neuroprotective agent for peripheral nerve injury repair in diabetes mellitus. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Medical countermeasure against respiratory toxicity and acute lung injury following inhalation exposure to chemical warfare nerve agent VX

    International Nuclear Information System (INIS)

    Nambiar, Madhusoodana P.; Gordon, Richard K.; Rezk, Peter E.; Katos, Alexander M.; Wajda, Nikolai A.; Moran, Theodore S.; Steele, Keith E.; Doctor, Bhupendra P.; Sciuto, Alfred M.

    2007-01-01

    To develop therapeutics against lung injury and respiratory toxicity following nerve agent VX exposure, we evaluated the protective efficacy of a number of potential pulmonary therapeutics. Guinea pigs were exposed to 27.03 mg/m 3 of VX or saline using a microinstillation inhalation exposure technique for 4 min and then the toxicity was assessed. Exposure to this dose of VX resulted in a 24-h survival rate of 52%. There was a significant increase in bronchoalveolar lavage (BAL) protein, total cell number, and cell death. Surprisingly, direct pulmonary treatment with surfactant, liquivent, N-acetylcysteine, dexamethasone, or anti-sense syk oligonucleotides 2 min post-exposure did not significantly increase the survival rate of VX-exposed guinea pigs. Further blocking the nostrils, airway, and bronchioles, VX-induced viscous mucous secretions were exacerbated by these aerosolized treatments. To overcome these events, we developed a strategy to protect the animals by treatment with atropine. Atropine inhibits muscarinic stimulation and markedly reduces the copious airway secretion following nerve agent exposure. Indeed, post-exposure treatment with atropine methyl bromide, which does not cross the blood-brain barrier, resulted in 100% survival of VX-exposed animals. Bronchoalveolar lavage from VX-exposed and atropine-treated animals exhibited lower protein levels, cell number, and cell death compared to VX-exposed controls, indicating less lung injury. When pulmonary therapeutics were combined with atropine, significant protection to VX-exposure was observed. These results indicate that combinations of pulmonary therapeutics with atropine or drugs that inhibit mucous secretion are important for the treatment of respiratory toxicity and lung injury following VX exposure

  2. In vivo decontamination of the nerve agent VX using the domestic swine model.

    Science.gov (United States)

    Misik, Jan; Pavlik, Michal; Novotny, Ladislav; Pavlikova, Ruzena; Chilcott, Robert P; Cabal, Jiri; Kuca, Kamil

    2012-11-01

    The purpose of this in vivo study was to assess a new, putatively optimised method for mass casualty decontamination ("ORCHIDS protocol") for effectiveness in removing the chemical warfare agent VX from the skin of anaesthetised, domestic white pigs. ORCHIDS protocol consists of a 1.5-minute shower with a mild detergent (Argos™) supplemented by physical removal. A standard method of wet decontamination was used for comparison. Experimental animals were divided into four groups (A-D). Two groups were exposed to a supra-lethal percutaneous dose (5 × LD(50); 300 μg kg(-1)) of VX for 1 h prior to decontamination with either the ORCHIDS (C) or standard protocol (D). A third (B, positive control) group was exposed but not subject to decontamination. Blank controls (A) received anaesthesia and the corresponding dose of normal saline instead of VX. Observations of the clinical signs of intoxication were supplemented by measurements of whole blood cholinesterase (ChE) performed on samples of arterial blood acquired at 30-minute intervals for the duration of the study (up to 6 h). Untreated (B) animals displayed typical cholinergic signs consistent with VX intoxication (local fasciculation, mastication, salivation, pilo-erection and motor convulsions) and died 165-240 min post exposure. All animals in both decontamination treatment groups (C, D) survived the duration of the study and exhibited less severe signs of cholinergic poisoning. Thus, both the standard and ORCHIDS protocol were demonstrably effective against exposure to the potent nerve agent VX, even after a delay of 1 h. A critical advantage of the ORCHIDS protocol is the relatively short shower duration (1½ min compared to 3 min). In practice, this could substantially improve the rate at which individuals could be decontaminated by emergency responders following exposure to toxic materials such as chemical warfare agents.

  3. Genipin-Cross-Linked Chitosan Nerve Conduits Containing TNF-α Inhibitors for Peripheral Nerve Repair.

    Science.gov (United States)

    Zhang, Li; Zhao, Weijia; Niu, Changmei; Zhou, Yujie; Shi, Haiyan; Wang, Yalin; Yang, Yumin; Tang, Xin

    2018-07-01

    Tissue engineered nerve grafts (TENGs) are considered a promising alternative to autologous nerve grafting, which is considered the "gold standard" clinical strategy for peripheral nerve repair. Here, we immobilized tumor necrosis factor-α (TNF-α) inhibitors onto a nerve conduit, which was introduced into a chitosan (CS) matrix scaffold utilizing genipin (GP) as the crosslinking agent, to fabricate CS-GP-TNF-α inhibitor nerve conduits. The in vitro release kinetics of TNF-α inhibitors from the CS-GP-TNF-α inhibitor nerve conduits were investigated using high-performance liquid chromatography. The in vivo continuous release profile of the TNF-α inhibitors released from the CS-GP-TNF-α inhibitor nerve conduits was measured using an enzyme-linked immunosorbent assay over 14 days. We found that the amount of TNF-α inhibitors released decreased with time after the bridging of the sciatic nerve defects in rats. Moreover, 4 and 12 weeks after surgery, histological analyses and functional evaluations were carried out to assess the influence of the TENG on regeneration. Immunochemistry performed 4 weeks after grafting to assess early regeneration outcomes revealed that the TENG strikingly promoted axonal outgrowth. Twelve weeks after grafting, the TENG accelerated myelin sheath formation, as well as functional restoration. In general, the regenerative outcomes following TENG more closely paralleled findings observed with autologous grafting than the use of the CS matrix scaffold. Collectively, our data indicate that the CS-GP-TNF-α inhibitor nerve conduits comprised an elaborate system for sustained release of TNF-α inhibitors in vitro, while studies in vivo demonstrated that the TENG could accelerate regenerating axonal outgrowth and functional restoration. The introduction of CS-GP-TNF-α-inhibitor nerve conduits into a scaffold may contribute to an efficient and adaptive immune microenvironment that can be used to facilitate peripheral nerve repair.

  4. Chemical warfare agents.

    Science.gov (United States)

    Kuca, Kamil; Pohanka, Miroslav

    2010-01-01

    Chemical warfare agents are compounds of different chemical structures. Simple molecules such as chlorine as well as complex structures such as ricin belong to this group. Nerve agents, vesicants, incapacitating agents, blood agents, lung-damaging agents, riot-control agents and several toxins are among chemical warfare agents. Although the use of these compounds is strictly prohibited, the possible misuse by terrorist groups is a reality nowadays. Owing to this fact, knowledge of the basic properties of these substances is of a high importance. This chapter briefly introduces the separate groups of chemical warfare agents together with their members and the potential therapy that should be applied in case someone is intoxicated by these agents.

  5. Wavelets and Sentiment in the Heterogeneous Agents Model

    Czech Academy of Sciences Publication Activity Database

    Vácha, Lukáš; Vošvrda, Miloslav

    2008-01-01

    Roč. 15, č. 25 (2008), s. 41-56 ISSN 1212-074X R&D Projects: GA ČR GP402/08/P207; GA ČR GA402/07/1113; GA ČR(CZ) GA402/06/0990 Institutional research plan: CEZ:AV0Z10750506 Keywords : heterogeneous agents model * market sentiment * Hurst exponent * wavelets Subject RIV: AH - Economics http://library.utia.cas.cz/separaty/2008/E/vacha-wavelets and sentiment in the heterogeneous agents model.pdf

  6. Fluorescent discrimination between traces of chemical warfare agents and their mimics.

    Science.gov (United States)

    Díaz de Greñu, Borja; Moreno, Daniel; Torroba, Tomás; Berg, Alexander; Gunnars, Johan; Nilsson, Tobias; Nyman, Rasmus; Persson, Milton; Pettersson, Johannes; Eklind, Ida; Wästerby, Pär

    2014-03-19

    An array of fluorogenic probes is able to discriminate between nerve agents, sarin, soman, tabun, VX and their mimics, in water or organic solvent, by qualitative fluorescence patterns and quantitative multivariate analysis, thus making the system suitable for the in-the-field detection of traces of chemical warfare agents as well as to differentiate between the real nerve agents and other related compounds.

  7. Natural Detoxification Capacity to Inactivate Nerve Agents Sarin and VX in the Rat Blood

    Directory of Open Access Journals (Sweden)

    Jiří Bajgar

    2016-03-01

    Full Text Available Background: The method of continual determination of the rat blood cholinesterase activity was developed to study the changes of the blood cholinesterases following different intervetions. Aims: The aim of this study is registration of cholinesterase activity in the rat blood and its changes to demonstrate detoxification capacity of rats to inactivate sarin or VX in vivo. Methods: The groups of female rats were premedicated (ketamine and xylazine and cannulated to a. femoralis. Continual blood sampling (0.02 ml/min and monitoring of the circulating blood cholinesterase activity were performed. Normal activity was monitored 1–2 min and then the nerve agent was administered i.m. (2× LD50. Using different time intervals of the leg compression and relaxation following the agent injection, cholinesterase activity was monitored and according to the inhibition obtained, detoxification capacity was assessed. Results: Administration of sarin to the leg, then 1 and 5 min compression and 20 min later relaxation showed that further inhibition in the blood was not observed. On the other hand, VX was able to inhibit blood cholinesterases after this intervention. Conclusions: The results demonstrated that sarin can be naturally detoxified on the contrary to VX. Described method can be used as model for other studies dealing with changes of cholinesterases in the blood following different factors.

  8. Comparisons of labeling efficiency, biological activity and biodistribution among 125I, 67Ga-DTPA- and 67Ga-DFO-lectins

    International Nuclear Information System (INIS)

    Kojima, Shuji; Jay, M.

    1987-01-01

    The labeling efficiency, biological activity and biodistribution of 125 I labeled and 67 Ga chelating agent conjugated lectins were investigated. Pisum sativum agglutinin (PSA) and Lens culinaris agglutinin (LCH) were efficiently labeled with 67 Ga using bifunctional chelating agents such as diethylenetriaminepentaacetic acid (DTPA) and deferoxamine (DFO), whereas labeling with 125 I was significantly less efficient. The agglutinating activity of these lectins towards Ehrlich ascites tumor (EAT) cells was retained on conjugation with DFO, but not with DTPA. The in vitro binding ratio of 67 Ga-DFO-lectins for EAT cells was almost the same as that of 125 I-lectins. However, the value was significantly decreased in the case of 67 Ga-DTPA-lectins. In the biodistribution study of radiolabeled lectins in Ehrlich solid tumor (EST) bearing mice, the accumulation of radioactivity in tumor tissue was very much less with 67 Ga-DTPA-lectins than with 125 I-lectins. However, the concentration was significantly elevated in the case of 67 Ga-DFO-lectins. While, these lectins accumulated in liver, spleen, lung, and kidney to a greater extent than 67 Ga citrate, the tumor to organ ratios became very low. These low tumor to organ ratios, in contrast to 67 Ga citrate, will certainly inhibit the tumor delineation, and therefore it seems that in spite of a high accumulation ratio of 67 Ga-DFO-lectins in tumor tissue, these agents are not useful in tumor detection. (orig.)

  9. Temporary Blindness after Inferior Alveolar Nerve Block.

    Science.gov (United States)

    Barodiya, Animesh; Thukral, Rishi; Agrawal, Shaila Mahendra; Rai, Anshul; Singh, Siddharth

    2017-03-01

    Inferior Alveolar Nerve Block (IANB) anaesthesia is one of the common procedures in dental clinic. This procedure is safe, but complications may still occur. Ocular complications such as diplopia, loss of vision, or ophthalmoplegia are extremely rare. This case report explains an event where due to individual anatomic variation of the sympathetic vasoconstrictor nerve and maxillary and middle meningeal arteries, intravascular administration of anaesthetic agent caused unusual ocular signs and symptoms such as temporary blindness.

  10. Stable-carbon isotope ratios for sourcing the nerve-agent precursor methylphosphonic dichloride and its products.

    Science.gov (United States)

    Moran, James J; Fraga, Carlos G; Nims, Megan K

    2018-08-15

    The ability to connect a chemical threat agent to a specific batch of a synthetic precursor can provide a fingerprint to contribute to effective forensic investigations. Stable isotope analysis can leverage intrinsic, natural isotopic variability within the molecules of a threat agent to unlock embedded chemical fingerprints in the material. Methylphosphonic dichloride (DC) is a chemical precursor to the nerve agent sarin. DC is converted to methylphosphonic difluoride (DF) as part of the sarin synthesis process. We used a suite of commercially available DC stocks to both evaluate the potential for δ 13 C analysis to be used as a fingerprinting tool in sarin-related investigations and to develop sample preparation techniques (using chemical hydrolysis) that can simplify isotopic analysis of DC and its synthetic products. We demonstrate that natural isotopic variability in DC results in at least three distinct, isotope-resolved clusters within the thirteen stocks we analyzed. Isotopic variability in the carbon feedstock (i.e., methanol) used for DC synthesis is likely inherited by the DC samples we measured. We demonstrate that the hydrolysis of DC and DF to methylphosphonic acid (MPA) can be used as a preparative step for isotopic analysis because the reaction does not impart a significant isotopic fractionation. MPA is more chemically stable, less toxic, and easier to handle than DC or DF. Further, the hydrolysis method we demonstrated can be applied to a suite of other precursors or to sarin itself, thereby providing a potentially valuable forensic tool. Copyright © 2018. Published by Elsevier B.V.

  11. Nanometric MIL-125-NH₂ Metal-Organic Framework as a Potential Nerve Agent Antidote Carrier.

    Science.gov (United States)

    Vilela, Sérgio M F; Salcedo-Abraira, Pablo; Colinet, Isabelle; Salles, Fabrice; de Koning, Martijn C; Joosen, Marloes J A; Serre, Christian; Horcajada, Patricia

    2017-10-12

    The three-dimensional (3D) microporous titanium aminoterephthalate MIL-125-NH₂ (MIL: Material of Institut Lavoisier) was successfully isolated as monodispersed nanoparticles, which are compatible with intravenous administration, by using a simple, safe and low-cost synthetic approach (100 °C/32 h under atmospheric pressure) so that for the first time it could be considered for encapsulation and the release of drugs. The nerve agent antidote 2-[(hydroxyimino)methyl]-1-methyl-pyridinium chloride (2-PAM or pralidoxime) was effectively encapsulated into the pores of MIL-125-NH₂ as a result of the interactions between 2-PAM and the pore walls being mediated by π-stacking and hydrogen bonds, as deduced from infrared spectroscopy and Monte Carlo simulation studies. Finally, colloidal solutions of MIL-125-NH₂ nanoparticles exhibited remarkable stability in different organic media, aqueous solutions at different pH and under relevant physiological conditions over time (24 h). 2-PAM was rapidly released from the pores of MIL-125-NH₂ in vitro.

  12. Comparative Evaluation of Using NOTA and DOTA Derivatives as Bifunctional Chelating Agents in the Preparation of 68Ga-Labeled Porphyrin: Impact on Pharmacokinetics and Tumor Uptake in a Mouse Model.

    Science.gov (United States)

    Guleria, Mohini; Das, Tapas; Amirdhanayagam, Jeyachitra; Sarma, Haladhar D; Dash, Ashutosh

    2018-02-01

    Both NOTA (1,4,7-triazacyclononane-1,4,7-triacetic acid) and DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) derivatives have been used as bifunctional chelating agents (BFCAs) for the preparation of 68 Ga-labeled target-specific agents having potential for positron emission tomography (PET) imaging of cancerous lesions. In the present work, the authors have attempted a comparative pharmacokinetic evaluation between 68 Ga-labeled porphyrins prepared using NOTA and DOTA derivatives as the BFCAs. A symmetrical porphyrin derivative, 5,10,15,20-tetrakis(p-carboxymethyleneoxyphenyl)porphyrin, was synthesized and coupled with two different BFCAs viz. p-NH 2 -benzyl-NOTA and p-NH 2 -benzyl-DOTA. Both the porphyrin-BFCA conjugates were radiolabeled with 68 Ga. A comparative bioevaluation involving pharmacokinetics and tumor affinity was performed in a tumor-bearing small animal model. Gallium-68-labeled porphyrin-amido-benzyl-NOTA and porphyrin-amido-benzyl-DOTA complexes were prepared with high radiochemical purity. Both radiolabeled complexes exhibited almost similar stability in human serum and near-identical tumor affinity and pharmacokinetic behavior in animal studies. The present study demonstrates that the pharmacokinetic behavior of 68 Ga-labeled porphyrin derivatives, prepared using either NOTA or DOTA derivatives as BFCAs, remains almost identical and hence both NOTA and DOTA derivatives could be considered equivalent for developing 68 Ga-based PET agents for imaging of tumorous lesions.

  13. Ga-68-DOTA-TATE PET/CT for discrimination of tumors of the optic pathway.

    Science.gov (United States)

    Klingenstein, Annemarie; Haug, Alexander R; Miller, Christina; Hintschich, Christoph

    2015-02-01

    Symptomatic tumors of the optic nerve pathway may endanger vision. They are difficult to classify by imaging alone and biopsy may damage visual function. Tumor pathology influences treatment decision and a diagnostic tool with a high sensitivity and specificity would therefore be invaluable. We hypothesized that Ga-68-DOTA-TATE PET/CT may help in discriminating optic nerve tumors as uptake of somatostatin is elevated in meningiomas. Ga-68-DOTA-TATE PET/CT was used to examine 13 patients with ambiguous, symptomatic lesions of the optic pathway for treatment planning. The presence or absence of meningioma was validated by histopathology or supplementary diagnostic work-up. Ga-68-DOTA-TATE PET/CT identified 10 meningiomas (en plaque = 1, optic nerve sheath = 4, sphenoidal = 5) correctly via increased SSTR (somatostatin receptor) expression (mean SUVmax (maximum standardized uptake value) = 14.3 ± 15.4). 3 tumors did not show elevated Ga-68-DOTA-TATE uptake (SUVmax = 2.1 ± 1.0). Subsumizing all clinical-radiological follow-up tools available, these lesions were classified as an intracerebral metastasis of an advanced gastric carcinoma, histologically proven inflammatory collagenous connective tissue and presumed leukemic infiltration of a newly diagnosed chronic lymphocytic leukemia. In this case series, Ga-68-DOTA-TATE PET/CT demonstrated both a sensitivity and specificity of 100%. Yet, the golden standard of histopathology was only available in a subset of patients included. Ga-68-DOTA-TATE PET/CT proved to be a valuable diagnostic tool for the correct classification of equivocal, symptomatic tumors of the anterior optic pathway requiring therapy. PET/CT results influenced therapy decision essentially in all cases.

  14. Blaptica dubia as sentinels for exposure to chemical warfare agents - a pilot study.

    Science.gov (United States)

    Worek, Franz; Seeger, Thomas; Neumaier, Katharina; Wille, Timo; Thiermann, Horst

    2016-11-16

    The increased interest of terrorist groups in toxic chemicals and chemical warfare agents presents a continuing threat to our societies. Early warning and detection is a key component for effective countermeasures against such deadly agents. Presently available and near term solutions have a number of major drawbacks, e.g. lack of automated, remote warning and detection of primarily low volatile chemical warfare agents. An alternative approach is the use of animals as sentinels for exposure to toxic chemicals. To overcome disadvantages of vertebrates the present pilot study was initiated to investigate the suitability of South American cockroaches (Blaptica dubia) as warning system for exposure to chemical warfare nerve and blister agents. Initial in vitro experiments with nerve agents showed an increasing inhibitory potency in the order tabun - cyclosarin - sarin - soman - VX of cockroach cholinesterase. Exposure of cockroaches to chemical warfare agents resulted in clearly visible and reproducible reactions, the onset being dependent on the agent and dose. With nerve agents the onset was related to the volatility of the agents. The blister agent lewisite induced signs largely comparable to those of nerve agents while sulfur mustard exposed animals exhibited a different sequence of events. In conclusion, this first pilot study indicates that Blaptica dubia could serve as a warning system to exposure of chemical warfare agents. A cockroach-based system will not detect or identify a particular chemical warfare agent but could trigger further actions, e.g. specific detection and increased protective status. By designing appropriate boxes with (IR) motion sensors and remote control (IR) camera automated off-site warning systems could be realized. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    International Nuclear Information System (INIS)

    Lin Yansong; Lin Xiangtong; Hu Mingyang; Pan Shangren; Wang Bocheng

    1996-01-01

    To study preparation of central nerves system dopamine D2 imaging agent 131 I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated 125 I-IBZM and 131 I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of 125 I-IBZM and 131 I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K d = 0.53 +- 0.06 nmol/L, B max = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high 125 I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high 125 -IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. 131 I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat's and rabbit's central nerves system dopamine D2 receptors

  16. In Vivo Reactivation by Oximes of Inhibited Blood, Brain and Peripheral Tissue Cholinesterase Activity Following Exposure to Nerve Agents in Guinea Pigs

    Science.gov (United States)

    2010-01-01

    nerve agent intoxication ( salivation , rhinorrhea, tremors,muscle asciculations, convulsions) at 60min following the 1.0× LD50 dose f GB, GF, VR or VX...reactivation of GF-, soman-, or VR-inhibited enzyme byHI-6 andHLö7. However, these in vitro experiments [24,25] were conducted with a pH of 8.0 at 25 ◦C...data. Even the study of Worek et al. [23] that was performed at a pH of 7.4 at 37 ◦C, whose in vitro kinetic data obtained from guinea pig RBC ghosts

  17. In Vivo Microdialysis and Electroencephalographic Activity in Freely Moving Guinea Pigs Exposed to Organophosphorus Nerve Agents Sarin and VX: Analysis of Acetylcholine and Glutamate

    Science.gov (United States)

    2011-01-01

    support the idea that there is a triphasic NT model for onset and progression of seizures and subsequent brain damage upon acute exposure to nerve agent...col- umn reactor (ACH-SPR Part No. 70-0640), and analytical cell (Model 5040) were all obtained from ESA Biosci- ences, Inc. (Chelmsford, MA...injection volume was 10 ll. To facilitate EC detection, a post-column reactor was utilized to convert ACh and Ch to hydrogen peroxide. The signal from

  18. The sources, fate, and toxicity of chemical warfare agent degradation products.

    Science.gov (United States)

    Munro, N B; Talmage, S S; Griffin, G D; Waters, L C; Watson, A P; King, J F; Hauschild, V

    1999-01-01

    We include in this review an assessment of the formation, environmental fate, and mammalian and ecotoxicity of CW agent degradation products relevant to environmental and occupational health. These parent CW agents include several vesicants: sulfur mustards [undistilled sulfur mustard (H), sulfur mustard (HD), and an HD/agent T mixture (HT)]; nitrogen mustards [ethylbis(2-chloroethyl)amine (HN1), methylbis(2-chloroethyl)amine (HN2), tris(2-chloroethyl)amine (HN3)], and Lewisite; four nerve agents (O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (VX), tabun (GA), sarin (GB), and soman (GD)); and the blood agent cyanogen chloride. The degradation processes considered here include hydrolysis, microbial degradation, oxidation, and photolysis. We also briefly address decontamination but not combustion processes. Because CW agents are generally not considered very persistent, certain degradation products of significant persistence, even those that are not particularly toxic, may indicate previous CW agent presence or that degradation has occurred. Of those products for which there are data on both environmental fate and toxicity, only a few are both environmentally persistent and highly toxic. Major degradation products estimated to be of significant persistence (weeks to years) include thiodiglycol for HD; Lewisite oxide for Lewisite; and ethyl methyl phosphonic acid, methyl phosphonic acid, and possibly S-(2-diisopropylaminoethyl) methylphosphonothioic acid (EA 2192) for VX. Methyl phosphonic acid is also the ultimate hydrolysis product of both GB and GD. The GB product, isopropyl methylphosphonic acid, and a closely related contaminant of GB, diisopropyl methylphosphonate, are also persistent. Of all of these compounds, only Lewisite oxide and EA 2192 possess high mammalian toxicity. Unlike other CW agents, sulfur mustard agents (e.g., HD) are somewhat persistent; therefore, sites or conditions involving potential HD contamination should include an

  19. Detection of nerve gases using surface-enhanced Raman scattering substrates with high droplet adhesion

    DEFF Research Database (Denmark)

    Hakonen, Aron; Rindzevicius, Tomas; Schmidt, Michael Stenbæk

    2016-01-01

    Threats from chemical warfare agents, commonly known as nerve gases, constitute a serious security issue of increasing global concern because of surging terrorist activity worldwide. However, nerve gases are difficult to detect using current analytical tools and outside dedicated laboratories. Here...... adhesion and nanopillar clustering due to elasto-capillary forces, resulting in enrichment of target molecules in plasmonic hot-spots with high Raman enhancement. The results may pave the way for strategic life-saving SERS detection of chemical warfare agents in the field....

  20. Terminal nerve: cranial nerve zero

    Directory of Open Access Journals (Sweden)

    Jorge Eduardo Duque Parra

    2006-12-01

    Full Text Available It has been stated, in different types of texts, that there are only twelve pairs of cranial nerves. Such texts exclude the existence of another cranial pair, the terminal nerve or even cranial zero. This paper considers the mentioned nerve like a cranial pair, specifying both its connections and its functional role in the migration of liberating neurons of the gonadotropic hormone (Gn RH. In this paper is also stated the hypothesis of the phylogenetic existence of a cerebral sector and a common nerve that integrates the terminal nerve with the olfactory nerves and the vomeronasals nerves which seem to carry out the odors detection function as well as in the food search, pheromone detection and nasal vascular regulation.

  1. Anastomotic stoma coated with chitosan film as a betamethasone dipropionate carrier for peripheral nerve regeneration

    Directory of Open Access Journals (Sweden)

    Ping Yao

    2018-01-01

    Full Text Available Scar hyperplasia at the suture site is an important reason for hindering the repair effect of peripheral nerve injury anastomosis. To address this issue, two repair methods are often used. Biological agents are used to block nerve sutures and the surrounding tissue to achieve physical anti-adhesion effects. Another agent is glucocorticosteroid, which can prevent scar growth by inhibiting inflammation. However, the overall effect of promoting regeneration of the injured nerve is not satisfactory. In this regard, we envision that these two methods can be combined and lead to shared understanding for achieving improved nerve repair. In this study, the right tibial nerve was transected 1 cm above the knee to establish a rat tibial nerve injury model. The incision was directly sutured after nerve transection. The anastomotic stoma was coated with 0.5 × 0.5 cm2 chitosan sheets with betamethasone dipropionate. At 12 weeks after injury, compared with the control and poly (D, L-lactic acid groups, chitosan-betamethasone dipropionate film slowly degraded with the shape of the membrane still intact. Further, scar hyperplasia and the degree of adhesion at anastomotic stoma were obviously reduced, while the regenerated nerve fiber structure was complete and arranged in a good order in model rats. Electrophysiological study showed enhanced compound muscle action potential. Our results confirm that chitosan-betamethasone dipropionate film can effectively prevent local scar hyperplasia after tibial nerve repair and promote nerve regeneration.

  2. Synthesis and Characterization of Fe3O4 Nanoparticles using Polyvinyl Alcohol (PVA) as Capping Agent and Glutaraldehyde (GA) as Crosslinker

    Science.gov (United States)

    Budi Hutami Rahayu, Lale; Oktavia Wulandari, Ika; Herry Santjojo, Djoko; Sabarudin, Akhmad

    2018-01-01

    The use of polyvinyl alcohol (PVA) as a capping agent and glutaraldehyde (GA) as a crosslinker for a synthesis of magnetite (Fe3O4) nanoparticles is able to reduce agglomeration of produced Fe3O4. Additionally, oxidation of Fe3O4 by air could be avoided. The synthesis is carried out in two steps: first step, magnetite (Fe3O4) nanoparticles were prepared by dissolving the FeCl3.6H2O and FeCl2.4H2O in alkaline media (NH3.H2O). The second step, magnetite nanoparticles were coated with polyvinyl alcohol (PVA) and glutaraldehyde (GA) to obtain Fe3O4-PVA-GA. The latter material was then characterized by FTIR to determine the typical functional groups of magnetite coated with PVA-GA. X-ray Diffraction analysis was used to determine structure and size of crystal as well as the percentage of magnetite produced. It was found that the produced nanoparticles have crystal sizes around 4-9 nm with the cubic crystal structure. The percentage of magnetite phase increases when the amount of glutaraldehyde increased. SEM-EDX was employed to assess the surface morphology and elemental composition of the resulted nanoparticles. The magnetic character of the magnetite and Fe3O4- PVA-GA were studied using Electron Spin Resonance.

  3. Destruction and waste treatment methods used in a chemical agent disposal project. Memorandum report

    Energy Technology Data Exchange (ETDEWEB)

    McAndless, J.; Fedor, V.; Kinderwater, T.

    1992-10-01

    This report describes the equipment and methods used to thermally decontaminate scrap metal and destroy stockpiles of nerve agents, mustard and lewisite chemical warfare agents. Mustard was destroyed by direct incineration whereas the nerve agents and lewisite were chemically neutralized. The arsenic waste from the lewisite neutralization process was chemically-fixated in concrete for final disposal by landfilling. The scrap metal was incinerated and rendered suitable for recycling into metal feedstock.

  4. Permeation Testing of Materials With Chemical Agents or Simulants (Swatch Testing)

    Science.gov (United States)

    2013-08-05

    nerve agents, sarin (GB), soman (GD), and persistent nerve agent (VX). These procedures can also be applied to toxic industrial chemicals (TICs...garment, cap, clothing liner, mask, glove, footwear , etc. The swatch should be selected to be representative of the area of the material to be tested...solvent and the extract analyzed. This reduces the sensitivity but obviates problems arising from one-shot thermal desorption. c. NRT and real

  5. Polysaccharide-thickened aqueous fluoride solutions for rapid destruction of the nerve agent VX. Introducing the opportunity for extensive decontamination scenarios.

    Science.gov (United States)

    Elias, Shlomi; Saphier, Sigal; Columbus, Ishay; Zafrani, Yossi

    2014-01-01

    Among the chemical warfare agents, the extremely toxic nerve agent VX (O-ethyl S-2-(diisopropylamino)ethyl methylphosphonothioate) is a target of high importance in the development of decontamination methods, due to its indefinite persistence on common environmental surfaces. Liquid decontaminants are mostly characterized by high corrosivity, usually offer poor coverage, and tend to flow and accumulate in low areas. Therefore, the development of a noncorrosive decontaminant, sufficiently viscous to resist dripping from the contaminated surface, is necessary. In the present paper we studied different polysaccharides-thickened fluoride aqueous solutions as noncorrosive decontaminants for rapid and efficient VX degradation to the nontoxic product EMPA (ethyl methylphosphonic acid). Polysaccharides are environmentally benign, natural, and inexpensive. Other known decontaminants cannot be thickened by polysaccharides, due to the sensitivity of the latter toward basic or oxidizing agents. We found that the efficiency of VX degradation in these viscous solutions in terms of kinetics and product identity is similar to that of KF aqueous solutions. Guar gum (1.5 wt %) with 4 wt % KF was chosen for further evaluation. The benign nature, rheological properties, adhering capabilities to different surfaces, and decontamination from a porous matrix were examined. This formulation showed promising properties for implementation as a spray decontaminant for common and sensitive environmental surfaces.

  6. Biomonitoring of exposure to chemical warfare agents

    NARCIS (Netherlands)

    Noort, D.; Schans, M.J. van der; Benschop, H.P.

    2006-01-01

    An overview is presented of the major methods that are presently available for biomonitoring of exposure to chemical warfare agents, i.e., nerve agents and sulfur mustard. These methods can be applied for a variety of purposes such as diagnosis and dosimetry of exposure of casualties, verification

  7. Nanometric MIL-125-NH2 Metal–Organic Framework as a Potential Nerve Agent Antidote Carrier

    Directory of Open Access Journals (Sweden)

    Sérgio M. F. Vilela

    2017-10-01

    Full Text Available The three-dimensional (3D microporous titanium aminoterephthalate MIL-125-NH2 (MIL: Material of Institut Lavoisier was successfully isolated as monodispersed nanoparticles, which are compatible with intravenous administration, by using a simple, safe and low-cost synthetic approach (100 °C/32 h under atmospheric pressure so that for the first time it could be considered for encapsulation and the release of drugs. The nerve agent antidote 2-[(hydroxyiminomethyl]-1-methyl-pyridinium chloride (2-PAM or pralidoxime was effectively encapsulated into the pores of MIL-125-NH2 as a result of the interactions between 2-PAM and the pore walls being mediated by π-stacking and hydrogen bonds, as deduced from infrared spectroscopy and Monte Carlo simulation studies. Finally, colloidal solutions of MIL-125-NH2 nanoparticles exhibited remarkable stability in different organic media, aqueous solutions at different pH and under relevant physiological conditions over time (24 h. 2-PAM was rapidly released from the pores of MIL-125-NH2 in vitro.

  8. Portable Sensor for Chemical Nerve Agents and Organophosphorus Compounds

    Science.gov (United States)

    2015-08-18

    as pesticides in crop, livestock, and poultry products and as chemical and biological warfare agents. As a result of the high toxicity and the...biomedical applications such as: tissue engineering, wound dressing materials, molecular imprinting, drug delivery, etc. In this experiment the hydrogel...agents have been exploited for use as pesticides in crop, livestock, and poultry products and as chemical and biological warfare agents. As a result of

  9. 68Ga-THP-PSMA: A PET Imaging Agent for Prostate Cancer Offering Rapid, Room-Temperature, 1-Step Kit-Based Radiolabeling.

    Science.gov (United States)

    Young, Jennifer D; Abbate, Vincenzo; Imberti, Cinzia; Meszaros, Levente K; Ma, Michelle T; Terry, Samantha Y A; Hider, Robert C; Mullen, Greg E; Blower, Philip J

    2017-08-01

    The clinical impact and accessibility of 68 Ga tracers for the prostate-specific membrane antigen (PSMA) and other targets would be greatly enhanced by the availability of a simple, 1-step kit-based labeling process. Radiopharmacy staff are accustomed to such procedures in the daily preparation of 99m Tc radiopharmaceuticals. Currently, chelating agents used in 68 Ga radiopharmaceuticals do not meet this ideal. The aim of this study was to develop and evaluate preclinically a 68 Ga radiotracer for imaging PSMA expression that could be radiolabeled simply by addition of 68 Ga generator eluate to a cold kit. Methods: A conjugate of a tris(hydroxypyridinone) (THP) chelator with the established urea-based PSMA inhibitor was synthesized and radiolabeled with 68 Ga by adding generator eluate directly to a vial containing the cold precursors THP-PSMA and sodium bicarbonate, with no further manipulation. It was analyzed after 5 min by instant thin-layer chromatography and high-performance liquid chromatography. The product was subjected to in vitro studies to determine PSMA affinity using PSMA-expressing DU145-PSMA cells, with their nonexpressing analog DU145 as a control. In vivo PET imaging and ex vivo biodistribution studies were performed in mice bearing xenografts of the same cell lines, comparing 68 Ga-THP-PSMA with 68 Ga-HBED-CC-PSMA. Results: Radiolabeling was complete (>95%) within 5 min at room temperature, showing a single radioactive species by high-performance liquid chromatography that was stable in human serum for more than 6 h and showed specific binding to PSMA-expressing cells (concentration giving 50% inhibition of 361 ± 60 nM). In vivo PET imaging showed specific uptake in PSMA-expressing tumors, reaching 5.6 ± 1.2 percentage injected dose per cubic centimeter at 40-60 min and rapid clearance from blood to kidney and bladder. The tumor uptake, biodistribution, and pharmacokinetics were not significantly different from those of 68 Ga

  10. PERFORATION OF INFERIOR ALVEOLAR NERVE BY MAXILLARY ARTERY. Perforation of inferior alveolar nerve by maxillary artery

    Directory of Open Access Journals (Sweden)

    Prakash B Billakanti

    2016-03-01

    Full Text Available La fosa infratemporal es un área anatómica clínicamente importante para la administración de agentes anestésicos locales en odontología y cirugía maxilofacial. Fueron estudiadas variaciones en la anatomía del nervio alveolar inferior y la arteria maxilar en la disección infratemporal. Durante la disección rutinaria de la cabeza en el cadáver de un varón adulto, fue observada una variación excepcional en el origen del nervio alveolar inferior y su relación con las estructuras circundantes. El nervio alveolar inferior se originaba en el nervio mandibular por dos raíces y la primera parte de la arteria maxilar estaba incorporada entre ambas. El origen embriológico de esta variación y sus implicaciones clínicas es debatido. Dado que la arteria maxilar transcurría entre las dos raíces del nervio alveolar inferior, y el nervio estaba fijado entre el foramen oval y el foramen mandibular, el atrapamiento vásculo-nervioso pudo causar entume-cimiento o dolor de cabeza e interferir con la inyección de anestésicos locales en la fosa infratemporal.  Variaciones anatómicas en esta región deben ser tenidas en cuenta, especialmente en casos de tratamiento fallido de neuralgia del trigémino. Infratemporal fossa is clinically important anatomical area for the delivery of local anesthetic agents in dentistry and maxillofacial surgery. Variations in the anatomy of the inferior alveolar nerve and maxillary artery were studied in infratemporal dissection. During routine dissection of the head in an adult male cadaver an unusual variation in the origin of the inferior alveolar nerve and its relationship with the surrounding structures was observed. The inferior alveolar nerve originated from the mandibular nerve by two roots and the first part of the maxillary artery was incorporated between them. An embryologic origin of this variation and its clinical implications is discussed. Because the maxillary artery runs between the two roots of

  11. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    Energy Technology Data Exchange (ETDEWEB)

    Yansong, Lin; Xiangtong, Lin; Mingyang, Hu; Shangren, Pan; Bocheng, Wang [Huashan Hospital of Shanghai Medical Univ., Shanghai (China)

    1996-11-01

    To study preparation of central nerves system dopamine D2 imaging agent {sup 131}I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated {sup 125}I-IBZM and {sup 131}I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of {sup 125}I-IBZM and {sup 131}I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K{sub d} = 0.53 +- 0.06 nmol/L, B{sub max} = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high {sup 125}I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high {sup 125}-IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. {sup 131}I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat`s and rabbit`s central nerves system dopamine D2 receptors.

  12. End-to-side neurorrhaphy repairs peripheral nerve injury: sensory nerve induces motor nerve regeneration.

    Science.gov (United States)

    Yu, Qing; Zhang, She-Hong; Wang, Tao; Peng, Feng; Han, Dong; Gu, Yu-Dong

    2017-10-01

    End-to-side neurorrhaphy is an option in the treatment of the long segment defects of a nerve. It involves suturing the distal stump of the disconnected nerve (recipient nerve) to the side of the intimate adjacent nerve (donor nerve). However, the motor-sensory specificity after end-to-side neurorrhaphy remains unclear. This study sought to evaluate whether cutaneous sensory nerve regeneration induces motor nerves after end-to-side neurorrhaphy. Thirty rats were randomized into three groups: (1) end-to-side neurorrhaphy using the ulnar nerve (mixed sensory and motor) as the donor nerve and the cutaneous antebrachii medialis nerve as the recipient nerve; (2) the sham group: ulnar nerve and cutaneous antebrachii medialis nerve were just exposed; and (3) the transected nerve group: cutaneous antebrachii medialis nerve was transected and the stumps were turned over and tied. At 5 months, acetylcholinesterase staining results showed that 34% ± 16% of the myelinated axons were stained in the end-to-side group, and none of the myelinated axons were stained in either the sham or transected nerve groups. Retrograde fluorescent tracing of spinal motor neurons and dorsal root ganglion showed the proportion of motor neurons from the cutaneous antebrachii medialis nerve of the end-to-side group was 21% ± 5%. In contrast, no motor neurons from the cutaneous antebrachii medialis nerve of the sham group and transected nerve group were found in the spinal cord segment. These results confirmed that motor neuron regeneration occurred after cutaneous nerve end-to-side neurorrhaphy.

  13. Enzymatic Analysis of G- and V-Agents and Their Degradation Products

    National Research Council Canada - National Science Library

    Elashvili, Ilya

    2003-01-01

    .... The nerve agents can be hydrolyzed to their respective methylphosphonate alkyl ester (h-agent) products by alkali treatment or by specific hydrolytic enzymes, such as organophosphorus hydrolase...

  14. Computational Intelligence Agent-Oriented Modelling

    Czech Academy of Sciences Publication Activity Database

    Neruda, Roman

    2006-01-01

    Roč. 5, č. 2 (2006), s. 430-433 ISSN 1109-2777 R&D Projects: GA MŠk 1M0567 Institutional research plan: CEZ:AV0Z10300504 Keywords : multi-agent systems * adaptive agents * computational intelligence Subject RIV: IN - Informatics, Computer Science

  15. A comparison of positron-emitting blood pool imaging agents

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Kulprathipanja, S.; Evans, G.; Elmaleh, D.

    1979-01-01

    The three agents, 11 C-carboxyhaemoglobin, 68 Ga-transferrin and 68 Ga-labelled red cells have been compared in dogs to assess their relative merits for blood-pool imaging. For 1 h following administration of each agent, periodic blood samples were withdrawn for counting in a NaI (Tl) well counter while conventional two-dimensional images were obtained simultaneously on the Massachusetts General Hospital positron camera. Count rates in regions about the heart, liver and spleen were obtained for each image. The disappearance of blood activity as shown from the results of counting the blood samples and from the counting rates in regions about the heart was found to be identical within experimental error for the three agents. In the liver and spleen regions, the highest count rates were obtained with 68 Ga-transferrin and the lowest with 68 Ga-labelled red cells; count rates in these regions with labelled red cells were virtually constant throughout the 1 h study. It may be concluded that with the exceptions noted above, the three agents are approximately equivalent for blood-pool imaging. (author)

  16. Enhanced catalytic activity through the tuning of micropore environment and supercritical CO2 processing: Al(porphyrin)-based porous organic polymers for the degradation of a nerve agent simulant.

    Science.gov (United States)

    Totten, Ryan K; Kim, Ye-Seong; Weston, Mitchell H; Farha, Omar K; Hupp, Joseph T; Nguyen, SonBinh T

    2013-08-14

    An Al(porphyrin) functionalized with a large axial ligand was incorporated into a porous organic polymer (POP) using a cobalt-catalyzed acetylene trimerization strategy. Removal of the axial ligand afforded a microporous POP that is catalytically active in the methanolysis of a nerve agent simulant. Supercritical CO2 processing of the POP dramatically increased the pore size and volume, allowing for significantly higher catalytic activities.

  17. 68Ga-Based Radiopharmaceuticals: Production and Application Relationship

    Directory of Open Access Journals (Sweden)

    Irina Velikyan

    2015-07-01

    Full Text Available The contribution of 68Ga to the promotion and expansion of clinical research and routine positron emission tomography (PET for earlier better diagnostics and individualized medicine is considerable. The potential applications of 68Ga-comprising imaging agents include targeted, pre-targeted and non-targeted imaging. This review discusses the key aspects of the production of 68Ga and 68Ga-based radiopharmaceuticals in the light of the impact of regulatory requirements and endpoint pre-clinical and clinical applications.

  18. Smart predictors in the heterogeneous agent model

    Czech Academy of Sciences Publication Activity Database

    Baruník, Jozef; Vácha, Lukáš; Vošvrda, Miloslav

    2009-01-01

    Roč. 4, č. 2 (2009), s. 163-172 ISSN 1860-711X R&D Projects: GA ČR GP402/08/P207; GA ČR GA402/09/0965 Grant - others:GAUK(CZ) 46108 Institutional research plan: CEZ:AV0Z10750506 Keywords : Heterogeneous agent model * Market structure * Smart traders * Hurst exponent Subject RIV: AH - Economics

  19. Identification of V-type nerve agents in vapor samples using a field-portable capillary gas chromatography/membrane-interfaced electron ionization quadrupole mass spectrometry instrument with Tri-Bed concentrator and fluoridating conversion tube.

    Science.gov (United States)

    Ohrui, Y; Nagoya, T; Kurimata, N; Sodeyama, M; Seto, Y

    2017-07-01

    A field-portable gas chromatography-mass spectrometry (GC-MS) system (Hapsite ER) was evaluated for the detection of nonvolatile V-type nerve agents (VX and Russian VX (RVX)) in the vapor phase. The Hapsite ER system consists of a Tri-Bed concentrator gas sampler, a nonpolar low thermal-mass capillary GC column and a hydrophobic membrane-interfaced electron ionization quadrupole mass spectrometer evacuated by a non-evaporative getter pump. The GC-MS system was attached to a VX-G fluoridating conversion tube containing silver nitrate and potassium fluoride. Sample vapors of VX and RVX were converted into O-ethyl methylphosphonofluoridate (EtGB) and O-isobutyl methylphosphonofluoridate (iBuGB), respectively. These fluoridated derivatives were detected within 10 min. No compounds were detected when the VX and RVX samples were analyzed without the conversion tube. A vapor sample of tabun (GA) was analyzed, in which GA and O-ethyl N,N-dimethylphosphoramidofluoridate were detected. The molar recovery percentages of EtGB and iBuGB from VX and RVX vapors varied from 0.3 to 17%, which was attributed to variations in the vaporization efficiency of the glass vapor container. The conversion efficiencies of the VX-G conversion tube for VX and RVX to their phosphonate derivatives were estimated to be 40%. VX and RVX vapors were detected at concentrations as low as 0.3 mg m -3 . Gasoline vapor was found to interfere with the analyses of VX and RVX. In the presence of 160 mg m -3 gasoline, the detection limits of VX and RVX vapor were increased to 20 mg m -3 . Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  20. NMR chemical shift and J coupling parameterization and quantum mechanical reference spectrum simulation for selected nerve agent degradation products in aqueous conditions.

    Science.gov (United States)

    Koskela, Harri; Anđelković, Boban

    2017-10-01

    The spectral parameters of selected nerve agent degradation products relevant to the Chemical Weapons Convention, namely, ethyl methylphosphonate, isopropyl methylphosphonate, pinacolyl methylphosphonate and methylphosphonic acid, were studied in wide range of pH conditions and selected temperatures. The pH and temperature dependence of chemical shifts and J couplings was parameterized using Henderson-Hasselbalch-based functions. The obtained parameters allowed calculation of precise chemical shifts and J coupling constants in arbitrary pH conditions and typical measurement temperatures, thus facilitating quantum mechanical simulation of reference spectra in the chosen magnetic field strength for chemical verification. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Heterogeneous Agent Model with Memory and Asset Price Behaviour

    Czech Academy of Sciences Publication Activity Database

    Vošvrda, Miloslav; Vácha, Lukáš

    2003-01-01

    Roč. 12, č. 2 (2003), s. 155-168 ISSN 1210-0455 R&D Projects: GA ČR GA402/00/0439; GA ČR GA402/01/0034 Institutional research plan: CEZ:AV0Z1075907 Keywords : efficient markets hypothesis * technical trading rules * heterogeneous agent model with memory and learning Subject RIV: AH - Economics

  2. FeGA: A feedback-generating agent

    NARCIS (Netherlands)

    Heuvelink, A.; Mioch, T.

    2008-01-01

    In current simulation-based training of knowledgeintensive tasks, human instructors are needed to evaluate a student's task performance. This paper reports a study into the development of a multi-agent-based training system that evaluates student behavior at the result-level (quality of performance)

  3. Primary screen for potential sheep scab control agents.

    Science.gov (United States)

    Dunn, J A; Prickett, J C; Collins, D A; Weaver, R J

    2016-07-15

    The efficacy of potential acaricidal agents were assessed against the sheep scab mite Psoroptes ovis using a series of in vitro assays in modified test arenas designed initially to maintain P. ovis off-host. The mortality effects of 45 control agents, including essential oils, detergents, desiccants, growth regulators, lipid synthesis inhibitors, nerve action/energy metabolism disruptors and ecdysteroids were assessed against adults and nymphs. The most effective candidates were the desiccants (diatomaceous earth, nanoclay and sorex), the growth regulators (buprofezin, hexythiazox and teflubenzuron), the lipid synthesis inhibitors (spirodiclofen, spirotetramat and spiromesifen) and the nerve action and energy metabolism inhibitors (fenpyroximate, spinosad, tolfenpyrad, and chlorantraniliprole). Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  4. Positive imaging of venous thrombi and thromboemboli with Ga-67 DFO-DAS-fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Kazutaka; Senda, Michio; Fujita, Toru; Yonekura, Yoshiharu; Kumada, Kaoru; Yokoyama, Akira; Torizuka, Kanji

    1988-05-01

    A newly developed thrombus imaging agent, /sup 67/Ga-DFO-DAS-fibrinogen (/sup 67/Ga-fibrinogen), was used for 22 studies in 20 cases of suspected deep venous thrombosis. Increased accumulation of /sup 67/Ga-fibrinogen in venous thrombi was depicted at 48 h after injection in 10 of the 15 cases (10 of 17 studies) who showed abnormal findings in radionuclide venography. A hot spot in the lung emboli was visualized in two cases. Seven of the eight cases having anticoagulant therapy showed increased /sup 67/Ga-fibrinogen uptake, while follow-up /sup 67/Ga-fibrinogen scintigraphy after the administration of heparin and urokinase did not reveal an abnormal hot spot in one case. /sup 67/Ga-fibrinogen can be made available simply by adding /sup 67/Ga solution to a vial containing fibrinogen-DAS-DFO conjugate. In conclusion, /sup 67/Ga-fibrinogen is considered to be a promising agent for detecting active venous thrombi and to assess the effect of anticoagulant therapy.

  5. Fate of chemical warfare agents and toxic industrial chemicals in landfills.

    Science.gov (United States)

    Bartelt-Hunt, Shannon L; Barlaz, Morton A; Knappe, Detlef R U; Kjeldsen, Peter

    2006-07-01

    One component of preparedness for a chemical attack is planning for the disposal of contaminated debris. To assess the feasibility of contaminated debris disposal in municipal solid waste (MSW) landfills, the fate of selected chemical warfare agents (CWAs) and toxic industrial chemicals (TICs) in MSW landfills was predicted with a mathematical model. Five blister agents [sulfur mustard (HD), nitrogen mustard (HN-2), lewisite (L), ethyldichloroarsine (ED), and phosgene oxime (CX)], eight nerve agents [tabun (GA), sarin (GB), soman (GD), GE, GF, VX, VG, and VM], one riot-control agent [CS], and two TICs [furan and carbon disulfide] were studied. The effects of both infiltration (climate) and contaminant biodegradability on fate predictions were assessed. Model results showed that hydrolysis and gas-phase advection were the principal fate pathways for CWAs and TICs, respectively. Apart from CX and the TICs, none of the investigated compounds was predicted to persist in a landfill for more than 5 years. Climate had little impact on CWA/TIC fate, and biodegradability was only important for compounds with long hydrolysis half-lives. Monte Carlo simulations were performed to assess the influence of uncertainty in model input parameters on CWA/TIC fate predictions. Correlation analyses showed that uncertainty in hydrolysis rate constants was the primary contributor to variance of CWA fate predictions, while uncertainty in the Henry's Law constant and landfill gas-production rate accounted for most of the variance of TIC fate predictions. CWA hydrolysates were more persistent than the parent CWAs, but limited information is available on abiotic or biotic transformation rates for these chemicals.

  6. Nerve Blocks

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Nerve Blocks A nerve block is an injection to ... the limitations of Nerve Block? What is a Nerve Block? A nerve block is an anesthetic and/ ...

  7. Early cyclosporin A treatment retards axonal degeneration in an experimental peripheral nerve injection injury model

    Directory of Open Access Journals (Sweden)

    Ibrahim Erkutlu

    2015-01-01

    Full Text Available Injury to peripheral nerves during injections of therapeutic agents such as penicillin G potassium is common in developing countries. It has been shown that cyclosporin A, a powerful immunosuppressive agent, can retard Wallerian degeneration after peripheral nerve crush injury. However, few studies are reported on the effects of cyclosporin A on peripheral nerve drug injection injury. This study aimed to assess the time-dependent efficacy of cyclosporine-A as an immunosuppressant therapy in an experimental rat nerve injection injury model established by penicillin G potassium injection. The rats were randomly divided into three groups based on the length of time after nerve injury induced by penicillin G potassium administration (30 minutes, 8 or 24 hours. The compound muscle action potentials were recorded pre-injury, early post-injury (within 1 hour and 4 weeks after injury and compared statistically. Tissue samples were taken from each animal for histological analysis. Compared to the control group, a significant improvement of the compound muscle action potential amplitude value was observed only when cyclosporine-A was administered within 30 minutes of the injection injury (P < 0.05; at 8 or 24 hours after cyclosporine-A administration, compound muscle action potential amplitude was not changed compared with the control group. Thus, early immunosuppressant drug therapy may be a good alternative neuroprotective therapy option in experimental nerve injection injury induced by penicillin G potassium injection.

  8. Preparation and evaluation of a radiogallium complex-conjugated bisphosphonate as a bone scintigraphy agent

    International Nuclear Information System (INIS)

    Ogawa, Kazuma; Takai, Kenichiro; Kanbara, Hiroya; Kiwada, Tatsuto; Kitamura, Yoji; Shiba, Kazuhiro; Odani, Akira

    2011-01-01

    Introduction: 68 Ga is a radionuclide of great interest as a positron emitter for positron emission tomography (PET). To develop a new bone-imaging agent with radiogallium, 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) was chosen as a chelating site and Ga-DOTA complex-conjugated bisphosphonate, which has a high affinity for bone, was prepared and evaluated. Although we are interested in developing 68 Ga-labeled bone imaging agents for PET, in these initial studies 67 Ga was used because of its longer half-life. Methods: DOTA-conjugated bisphosphonate (DOTA-Bn-SCN-HBP) was synthesized by conjugation of 2-(4-isothiocyanatebenzyl)-1,4,7,10-tetraazacyclododecane-1,4,7, 10-tetraacetic acid to 4-amino-1-hydroxybutylidene-1,1-bisphosphonate (alendronate). 67 Ga-DOTA-Bn-SCN-HBP was prepared by coordination with 67 Ga, and its in vitro and in vivo evaluations were performed. Results: 67 Ga-DOTA-Bn-SCN-HBP was prepared with a radiochemical purity of over 95% without purification. 67 Ga-DOTA-Bn-SCN-HBP had great affinity for hydroxyapatite in binding assay. In biodistribution experiments, 67 Ga-DOTA-Bn-SCN-HBP accumulated in bone rapidly but was hardly observed in tissues other than bone. Pretreatment of an excess amount of alendronate inhibited the bone accumulation of 67 Ga-DOTA-Bn-SCN-HBP. Conclusions: 67 Ga-DOTA-Bn-SCN-HBP showed ideal biodistribution characteristics as a bone-imaging agent. These findings should provide useful information on the drug design of bone imaging agents for PET with 68 Ga.

  9. Biomonitoring of exposure to chemical warfare agents: A review

    NARCIS (Netherlands)

    Noort, D.; Benschop, H.P.; Black, R.M.

    2002-01-01

    In this report an overview of the methods currently available for detection of exposure to a number of chemical warfare agents (CWA), i.e., sulfur mustard, lewisite and nerve agents, is presented. Such methods can be applied for various purposes, e.g., diagnosis and dosimetry of exposure of

  10. Bilateral changes in IL-6 protein, but not in its receptor gp130, in rat dorsal root ganglia following sciatic nerve ligature

    Czech Academy of Sciences Publication Activity Database

    Brázda, Václav; Klusáková, I.; Svíženská, I.; Veselková, Z.; Dubový, P.

    2009-01-01

    Roč. 29, 6-7 (2009), s. 1053-1062 ISSN 0272-4340 Grant - others:GA ČR(CZ) GA309/07/0121 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : unilateral nerve injury * neuropathic pain * IL-6 signaling Subject RIV: BO - Biophysics Impact factor: 2.107, year: 2009

  11. A rat model of nerve agent exposure applicable to the pediatric population: The anticonvulsant efficacies of atropine and GluK1 antagonists.

    Science.gov (United States)

    Miller, Steven L; Aroniadou-Anderjaska, Vassiliki; Figueiredo, Taiza H; Prager, Eric M; Almeida-Suhett, Camila P; Apland, James P; Braga, Maria F M

    2015-04-15

    Inhibition of acetylcholinesterase (AChE) after nerve agent exposure induces status epilepticus (SE), which causes brain damage or death. The development of countermeasures appropriate for the pediatric population requires testing of anticonvulsant treatments in immature animals. In the present study, exposure of 21-day-old (P21) rats to different doses of soman, followed by probit analysis, produced an LD50 of 62μg/kg. The onset of behaviorally-observed SE was accompanied by a dramatic decrease in brain AChE activity; rats who did not develop SE had significantly less reduction of AChE activity in the basolateral amygdala than rats who developed SE. Atropine sulfate (ATS) at 2mg/kg, administered 20 min after soman exposure (1.2×LD50), terminated seizures. ATS at 0.5mg/kg, given along with an oxime within 1 min after exposure, allowed testing of anticonvulsants at delayed time-points. The AMPA/GluK1 receptor antagonist LY293558, or the specific GluK1 antagonist UBP302, administered 1h post-exposure, terminated SE. There were no degenerating neurons in soman-exposed P21 rats, but both the amygdala and the hippocampus were smaller than in control rats at 30 and 90days post-exposure; this pathology was not present in rats treated with LY293558. Behavioral deficits present at 30 days post-exposure, were also prevented by LY293558 treatment. Thus, in immature animals, a single injection of atropine is sufficient to halt nerve agent-induced seizures, if administered timely. Testing anticonvulsants at delayed time-points requires early administration of ATS at a low dose, sufficient to counteract only peripheral toxicity. LY293558 administered 1h post-exposure, prevents brain pathology and behavioral deficits. Published by Elsevier Inc.

  12. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  13. Acellular Nerve Allografts in Peripheral Nerve Regeneration: A Comparative Study

    Science.gov (United States)

    Moore, Amy M.; MacEwan, Matthew; Santosa, Katherine B.; Chenard, Kristofer E.; Ray, Wilson Z.; Hunter, Daniel A.; Mackinnon, Susan E.; Johnson, Philip J.

    2011-01-01

    Background Processed nerve allografts offer a promising alternative to nerve autografts in the surgical management of peripheral nerve injuries where short deficits exist. Methods Three established models of acellular nerve allograft (cold-preserved, detergent-processed, and AxoGen® -processed nerve allografts) were compared to nerve isografts and silicone nerve guidance conduits in a 14 mm rat sciatic nerve defect. Results All acellular nerve grafts were superior to silicone nerve conduits in support of nerve regeneration. Detergent-processed allografts were similar to isografts at 6 weeks post-operatively, while AxoGen®-processed and cold-preserved allografts supported significantly fewer regenerating nerve fibers. Measurement of muscle force confirmed that detergent-processed allografts promoted isograft-equivalent levels of motor recovery 16 weeks post-operatively. All acellular allografts promoted greater amounts of motor recovery compared to silicone conduits. Conclusions These findings provide evidence that differential processing for removal of cellular constituents in preparing acellular nerve allografts affects recovery in vivo. PMID:21660979

  14. Preparation and evaluation of a radiogallium complex-conjugated bisphosphonate as a bone scintigraphy agent

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Kazuma, E-mail: kogawa@p.kanazawa-u.ac.jp [Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa 920-1192 (Japan); Takai, Kenichiro; Kanbara, Hiroya; Kiwada, Tatsuto [Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa 920-1192 (Japan); Kitamura, Yoji; Shiba, Kazuhiro [Advanced Science Research Center, Kanazawa University, Kanazawa 920-8640 (Japan); Odani, Akira [Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa 920-1192 (Japan)

    2011-07-15

    Introduction: {sup 68}Ga is a radionuclide of great interest as a positron emitter for positron emission tomography (PET). To develop a new bone-imaging agent with radiogallium, 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) was chosen as a chelating site and Ga-DOTA complex-conjugated bisphosphonate, which has a high affinity for bone, was prepared and evaluated. Although we are interested in developing {sup 68}Ga-labeled bone imaging agents for PET, in these initial studies {sup 67}Ga was used because of its longer half-life. Methods: DOTA-conjugated bisphosphonate (DOTA-Bn-SCN-HBP) was synthesized by conjugation of 2-(4-isothiocyanatebenzyl)-1,4,7,10-tetraazacyclododecane-1,4,7, 10-tetraacetic acid to 4-amino-1-hydroxybutylidene-1,1-bisphosphonate (alendronate). {sup 67}Ga-DOTA-Bn-SCN-HBP was prepared by coordination with {sup 67}Ga, and its in vitro and in vivo evaluations were performed. Results: {sup 67}Ga-DOTA-Bn-SCN-HBP was prepared with a radiochemical purity of over 95% without purification. {sup 67}Ga-DOTA-Bn-SCN-HBP had great affinity for hydroxyapatite in binding assay. In biodistribution experiments, {sup 67}Ga-DOTA-Bn-SCN-HBP accumulated in bone rapidly but was hardly observed in tissues other than bone. Pretreatment of an excess amount of alendronate inhibited the bone accumulation of {sup 67}Ga-DOTA-Bn-SCN-HBP. Conclusions: {sup 67}Ga-DOTA-Bn-SCN-HBP showed ideal biodistribution characteristics as a bone-imaging agent. These findings should provide useful information on the drug design of bone imaging agents for PET with {sup 68}Ga.

  15. Radiolabelling of DTPA with Ga-67

    International Nuclear Information System (INIS)

    Hamadah, N.; Shaiban, M. R.

    2012-08-01

    Gallium-68 or 67 has been used since the 1970s of the last century. One of the most important uses is the labelling of antibodies using chelating agents, which forms relatively stable complexes to be used in therapeutical and diagnostic applications. Diethylenetriaminepentaacetic acid (DTPA) is a bifunctional chelating agent; has many uses in the preparation of radiopharmaceuticals. We tried in this study the adaptation of DTPA labelling with Ga-67 (which has a longer half-life than Ga-68). This radioisotope gives better time for chemical manipulation. The labelling procedure was carried out under different pH conditions. We found that the best pH is 5 and that the complex is relatively stable for more than 6 hours at room temperature; with a labelling yield >90%. (authors)

  16. Vascularized nerve grafts for lower extremity nerve reconstruction.

    Science.gov (United States)

    Terzis, Julia K; Kostopoulos, Vasileios K

    2010-02-01

    Vascularized nerve grafts (VNG) were introduced in 1976 but since then, there have been no reports of their usage in lower extremity reconstruction systematically. The factors influencing outcomes as well as a comparison with conventional nerve grafts will be presented.Since 1981, 14 lower extremity nerve injuries in 12 patients have been reconstructed with VNG. Common peroneal nerve was injured in 12 and posterior tibial nerve in 5 patients. The level of the injury was at the knee or thigh. Twelve sural nerves were used as VNG with or without concomitant vascularized posterior calf fascia.All patients regained improved sensibility and adequate posterior tibial nerve function. For common peroneal nerve reconstructions, all patients with denervation time less than 6 months regained muscle strength of grade at least 4, even when long grafts were used for defects of 20 cm or more. Late cases, yielded inadequate muscle function even with the use of VNG.Denervation time of 6 months or less was critical for reconstruction with vascularized nerve graft. Not only the results were statistically significant compared with late cases, but also all early operated patients achieved excellent results. VNG are strongly recommended in traction avulsion injuries of the lower extremity with lengthy nerve damage.

  17. Preliminary PET/CT Imaging with Somatostatin Analogs [68Ga]DOTAGA-TATE and [68Ga]DOTAGA-TOC.

    Science.gov (United States)

    Satpati, Drishty; Shinto, Ajit; Kamaleshwaran, K K; Sarma, Haladhar Dev; Dash, Ashutosh

    2017-12-01

    Somatostatin receptor positron emission tomography/X-ray computed tomography (SSTR-PET/CT) is a well-established technique for staging and detection of neuroendocrine tumors (NETs). Ga-68-labeled DOTA-conjugated octreotide analogs are the privileged radiotracers for diagnosis and therapeutic monitoring of NETs. Hence, we were interested in assessing the influence of promising, newer variant DOTAGA on the hydrophilicity, pharmacokinetics, and lesion pick-up of somatostatin analogs. Herein, the potential of ([ 68 Ga]DOTAGA, Tyr 3 , Thr 8 ) octreotide ([ 68 Ga]DOTAGA-TATE) and ([ 68 Ga]DOTAGA, Tyr 3 ) octreotide ([ 68 Ga]DOTAGA-TOC) as NET imaging agents has been investigated. Amenability of [ 68 Ga]DOTAGA-(TATE/TOC) to kit-type formulation has been demonstrated. Biodistribution studies were carried out in normal rats at 1 h post-injection (p.i.). [ 68 Ga]DOTAGA-(TATE/TOC) PET/CT scans were carried out in patients (70-170 MBq, 1 h p.i.) with histologically confirmed well-differentiated NETs. [ 68 Ga]DOTAGA-TATE exhibited hydrophilicity similar to [ 68 Ga]DOTA-TATE (log P = -3.51 vs -3.69) whereas [ 68 Ga]DOTAGA-TOC was more hydrophilic than [ 68 Ga]DOTA-TOC (log P = -3.27 vs -2.93). [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTA-TATE showed almost identical blood and kidney uptake in normal rats whereas significantly fast clearance (p TOC also demonstrated rapid clearance from blood and kidneys (p TOC. The metastatic lesions in NET patients were well identified by [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTAGA-TOC. The phenomenal analogy was observed between [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTA-TATE as well as between [ 68 Ga]DOTAGA-TOC and [ 68 Ga]DOTA-TOC in biodistribution studies in rats. The good lesion detection ability of the two radiotracers indicates their potential as NET imaging radiotracers.

  18. Nerve Cross-Bridging to Enhance Nerve Regeneration in a Rat Model of Delayed Nerve Repair

    Science.gov (United States)

    2015-01-01

    There are currently no available options to promote nerve regeneration through chronically denervated distal nerve stumps. Here we used a rat model of delayed nerve repair asking of prior insertion of side-to-side cross-bridges between a donor tibial (TIB) nerve and a recipient denervated common peroneal (CP) nerve stump ameliorates poor nerve regeneration. First, numbers of retrogradely-labelled TIB neurons that grew axons into the nerve stump within three months, increased with the size of the perineurial windows opened in the TIB and CP nerves. Equal numbers of donor TIB axons regenerated into CP stumps either side of the cross-bridges, not being affected by target neurotrophic effects, or by removing the perineurium to insert 5-9 cross-bridges. Second, CP nerve stumps were coapted three months after inserting 0-9 cross-bridges and the number of 1) CP neurons that regenerated their axons within three months or 2) CP motor nerves that reinnervated the extensor digitorum longus (EDL) muscle within five months was determined by counting and motor unit number estimation (MUNE), respectively. We found that three but not more cross-bridges promoted the regeneration of axons and reinnervation of EDL muscle by all the CP motoneurons as compared to only 33% regenerating their axons when no cross-bridges were inserted. The same 3-fold increase in sensory nerve regeneration was found. In conclusion, side-to-side cross-bridges ameliorate poor regeneration after delayed nerve repair possibly by sustaining the growth-permissive state of denervated nerve stumps. Such autografts may be used in human repair surgery to improve outcomes after unavoidable delays. PMID:26016986

  19. Nerve conduction and excitability studies in peripheral nerve disorders

    DEFF Research Database (Denmark)

    Krarup, Christian; Moldovan, Mihai

    2009-01-01

    counterparts in the peripheral nervous system, in some instances without peripheral nervous system symptoms. Both hereditary and acquired demyelinating neuropathies have been studied and the effects on nerve pathophysiology have been compared with degeneration and regeneration of axons. SUMMARY: Excitability......PURPOSE OF REVIEW: The review is aimed at providing information about the role of nerve excitability studies in peripheral nerve disorders. It has been known for many years that the insight into peripheral nerve pathophysiology provided by conventional nerve conduction studies is limited. Nerve...... excitability studies are relatively novel but are acquiring an increasingly important role in the study of peripheral nerves. RECENT FINDINGS: By measuring responses in nerve that are related to nodal function (strength-duration time constant, rheobase and recovery cycle) and internodal function (threshold...

  20. Recent canadian experience in chemical warfare agent destruction. An overview

    Energy Technology Data Exchange (ETDEWEB)

    McAndless, J.M.

    1995-09-01

    A Canadian chemical warfare agent destruction project (Swiftsure) was recently completed in which stockpiles of aged mustard, lewisite, nerve agents and contaminated scrap metal were incinerated or chemically neutralized in a safe, environmentally-responsible manner. The project scope, destruction technologies, environmental monitoring and public consultation programs are described.

  1. Atraumatic Main-En-Griffe due to Ulnar Nerve Leprosy

    International Nuclear Information System (INIS)

    Aswani, Yashant; Saifi, Shenaz

    2016-01-01

    Leprosy is the most common form of treatable peripheral neuropathy. However, in spite of effective chemotherapeutic agents, neuropathy and associated deformities are seldom ameliorated to a significant extent. This necessitates early diagnosis and treatment. Clinical examination of peripheral nerves is highly subjective and inaccurate. Electrophysiological studies are painful and expensive. Ultrasonography circumvents these demerits and has emerged as the preferred modality for probing peripheral nerves. We describe a 23-year-old male who presented with weakness and clawing of the medial digits of the right hand (main-en-griffe) and a few skin lesions since eighteen months. The right ulnar nerve was thickened and exquisitely tender on palpation. Ultrasonography revealed an extensive enlargement of the nerve with presence of intraneural color Doppler signals suggestive of acute neuritis. Skin biopsy was consistent with borderline tuberculoid leprosy with type 1 lepra reaction. The patient was started on WHO multidrug therapy for paucibacillary leprosy along with antiinflammatory drugs. Persistence of vascular signals at two months’ follow-up has led to continuation of the steroid therapy. The patient is compliant with the treatment and is on monthly follow-up. In this manuscript, we review multitudinous roles of ultrasonography in examination of peripheral nerves in leprosy. Ultrasonography besides diagnosing enlargement of nerves in leprosy and acute neuritis due to lepra reactions, guides the duration of anti-inflammatory therapy in lepra reactions. Further, it is relatively inexpensive, non-invasive and easily available. All these features make ultrasonography a preferred modality for examination of peripheral nerves

  2. External laryngeal nerve in thyroid surgery: is the nerve stimulator necessary?

    Science.gov (United States)

    Aina, E N; Hisham, A N

    2001-09-01

    To find out the incidence and type of external laryngeal nerves during operations on the thyroid, and to assess the role of a nerve stimulator in detecting them. Prospective, non-randomised study. Teaching hospital, Malaysia. 317 patients who had 447 dissections between early January 1998 and late November 1999. Number and type of nerves crossing the cricothyroid space, and the usefulness of the nerve stimulator in finding them. The nerve stimulator was used in 206/447 dissections (46%). 392 external laryngeal nerves were seen (88%), of which 196/206 (95%) were detected with the stimulator. However, without the stimulator 196 nerves were detected out of 241 dissections (81%). The stimulator detected 47 (23%) Type I nerves (nerve > 1 cm from the upper edge of superior pole); 86 (42%) Type IIa nerves (nerve edge of superior pole); and 63 (31%) Type IIb nerves (nerve below upper edge of superior pole). 10 nerves were not detected. When the stimulator was not used the corresponding figures were 32 (13%), 113 (47%), and 51 (21%), and 45 nerves were not seen. If the nerve cannot be found we recommend dissection of capsule close to the medial border of the upper pole of the thyroid to avoid injury to the nerve. Although the use of the nerve stimulator seems desirable, it confers no added advantage in finding the nerve. In the event of uncertainty about whether a structure is the nerve, the stimulator may help to confirm it. However, exposure of the cricothyroid space is most important for good exposure in searching for the external laryngeal nerve.

  3. Limitations and challenges in treatment of acute chemical warfare agent poisoning.

    Science.gov (United States)

    Thiermann, Horst; Worek, Franz; Kehe, Kai

    2013-12-05

    Recent news from Syria on a possible use of chemical warfare agents made the headlines. Furthermore, the motivation of terrorists to cause maximal harm shifts these agents into the public focus. For incidents with mass casualties appropriate medical countermeasures must be available. At present, the most important threats arise from nerve agents and sulfur mustard. At first, self-protection and protection of medical units from contamination is of utmost importance. Volatile nerve agent exposure, e.g. sarin, results in fast development of cholinergic crisis. Immediate clinical diagnosis can be confirmed on-site by assessment of acetylcholinesterase activity. Treatment with autoinjectors that are filled with 2mg atropine and an oxime (at present obidoxime, pralidoxime, TMB-4 or HI-6) are not effective against all nerve agents. A more aggressive atropinisation has to be considered and more effective oximes (if possible with a broad spectrum or a combination of different oximes) as well as alternative strategies to cope with high acetylcholine levels at synaptic sites should be developed. A further gap exists for the treatment of patients with sustained cholinergic crisis that has to be expected after exposure to persistent nerve agents, e.g. VX. The requirement for long-lasting artificial ventilation can be reduced with an oxime therapy that is optimized by using the cholinesterase status for guidance or by measures (e.g. scavengers) that are able to reduce the poison load substantially in the patients. For sulfur mustard poisoning no specific antidote is available until now. Symptomatic measures as used for treatment of burns are recommended together with surgical or laser debridement. Thus, huge amounts of resources are expected to be consumed as wound healing is impaired. Possible depots of sulfur mustard in tissues may aggravate the situation. More basic knowledge is necessary to improve substantially therapeutic options. The use of stem cells may provide a new

  4. Chitin biological absorbable catheters bridging sural nerve grafts transplanted into sciatic nerve defects promote nerve regeneration.

    Science.gov (United States)

    Wang, Zhi-Yong; Wang, Jian-Wei; Qin, Li-Hua; Zhang, Wei-Guang; Zhang, Pei-Xun; Jiang, Bao-Guo

    2018-06-01

    To investigate the efficacy of chitin biological absorbable catheters in a rat model of autologous nerve transplantation. A segment of sciatic nerve was removed to produce a sciatic nerve defect, and the sural nerve was cut from the ipsilateral leg and used as a graft to bridge the defect, with or without use of a chitin biological absorbable catheter surrounding the graft. The number and morphology of regenerating myelinated fibers, nerve conduction velocity, nerve function index, triceps surae muscle morphology, and sensory function were evaluated at 9 and 12 months after surgery. All of the above parameters were improved in rats in which the nerve graft was bridged with chitin biological absorbable catheters compared with rats without catheters. The results of this study indicate that use of chitin biological absorbable catheters to surround sural nerve grafts bridging sciatic nerve defects promotes recovery of structural, motor, and sensory function and improves muscle fiber morphology. © 2018 John Wiley & Sons Ltd.

  5. Synthesis and biodistribution of lipophilic and monocationic gallium radiopharmaceuticals derived from N,N'-bis(3-aminopropyl)-N,N'-dimethylethylenediamine: potential agents for PET myocardial imaging with 68Ga

    International Nuclear Information System (INIS)

    Hsiao, Y.-M.; Mathias, Carla J.; Wey, S.-P.; Fanwick, Phillip E.; Green, Mark A.

    2009-01-01

    Introduction: In locations that lack nearby cyclotron facilities for radionuclide production, generator-based 68 Ga radiopharmaceuticals might have clinical utility for positron emission tomography (PET) studies of myocardial perfusion and other physiological processes. Methods: The lipophilic and monocationic 67 Ga-labeled gallium chelates of five novel hexadentate bis(salicylaldimine) ligands the bis(salicylaldimine), bis(3-methoxysalicylaldimine), bis(4-methoxysalicylaldimine), bis(6-meth,oxysalicylaldimine), and bis(4,6-dimethoxysalicylaldimine) of N,N'-bis(3-aminopropyl)-N,N'-dimethylethylenediamine (BAPDMEN), were prepared. The structure of the unlabeled [Ga(4-MeOsal) 2 BAPDMEN] + PF 6 - salt was determined by X-ray crystallography, and the biodistribution of each of the 67 Ga-labeled gallium chelates was determined in rats following intravenous administration and compared with the biodistribution of [ 86 Rb]rubidium chloride. Results: The [Ga(4-MeOsal) 2 BAPDMEN] + PF 6 - complex exhibited the expected pseudo-octahedral N 4 O 2 2- coordination sphere about the Ga 3+ center with a trans disposition of the phenolate oxygen atoms. All five 67 Ga radiopharmaceuticals were found to afford the desired myocardial retention of the radiogallium. The [ 67/68 Ga][Ga(3-MeOsal) 2 BAPDMEN] 1+ radiopharmaceutical appears to have the best properties for myocardial imaging, exhibiting 2% of the injected dose in the heart 1 min and 2 h postinjection and very high heart/nontarget ratios (heart/blood ratios of 7.6±1.0 and 54±10 at 1 and 120 min, respectively; heart/liver ratios of 1.8±0.4 and 39±3 at 1 and 120 min, respectively). Conclusions: Most of these new agents, particularly [ 67/68 Ga][Ga(3-MeOsal) 2 BAPDMEN] 1+ , would appear superior to previously reported bis(salicylaldimine) ligands of N,N'-bis(3-aminopropyl)ethylenediamine as candidates for PET imaging of the heart with 68 Ga

  6. A novel method of lengthening the accessory nerve for direct coaptation during nerve repair and nerve transfer procedures.

    Science.gov (United States)

    Tubbs, R Shane; Maldonado, Andrés A; Stoves, Yolanda; Fries, Fabian N; Li, Rong; Loukas, Marios; Oskouian, Rod J; Spinner, Robert J

    2018-01-01

    OBJECTIVE The accessory nerve is frequently repaired or used for nerve transfer. The length of accessory nerve available is often insufficient or marginal (under tension) for allowing direct coaptation during nerve repair or nerve transfer (neurotization), necessitating an interpositional graft. An attractive maneuver would facilitate lengthening of the accessory nerve for direct coaptation. The aim of the present study was to identify an anatomical method for such lengthening. METHODS In 20 adult cadavers, the C-2 or C-3 connections to the accessory nerve were identified medial to the sternocleidomastoid (SCM) muscle and the anatomy of the accessory nerve/cervical nerve fibers within the SCM was documented. The cervical nerve connections were cut. Lengths of the accessory nerve were measured. Samples of the cut C-2 and C-3 nerves were examined using immunohistochemistry. RESULTS The anatomy and adjacent neural connections within the SCM are complicated. However, after the accessory nerve was "detethered" from within the SCM and following transection, the additional length of the accessory nerve increased from a mean of 6 cm to a mean of 10.5 cm (increase of 4.5 cm) after cutting the C-2 connections, and from a mean of 6 cm to a mean length of 9 cm (increase of 3.5 cm) after cutting the C-3 connections. The additional length of accessory nerve even allowed direct repair of an infraclavicular target (i.e., the proximal musculocutaneous nerve). The cervical nerve connections were shown not to contain motor fibers. CONCLUSIONS An additional length of the accessory nerve made available in the posterior cervical triangle can facilitate direct repair or neurotization procedures, thus eliminating the need for an interpositional nerve graft, decreasing the time/distance for regeneration and potentially improving clinical outcomes.

  7. Biodegradation of Organophosphate Chemical Warfare Agents by Activated Sludge

    Science.gov (United States)

    2012-03-01

    bronchoconstriction Bladder (M) Urinary frequency, incontinence Cardiovascular system (M) Bradycardia, hypotension Cardiovascular system (N...conventional weapons: their cost and stability, simplicity of production, pound for pound potency and fear factor (Hill et al., 2008a). Compared to...Chemical agents, especially nerve agents, have a dramatic fear factor due to the symptoms they cause. Witnessing civilians violently convulsing

  8. Effects of endogenous nitric oxide on adrenergic nerve-mediated vasoconstriction and calcitonin gene-related peptide-containing nerve-mediated vasodilation in pithed rats.

    Science.gov (United States)

    Yamawaki, Kousuke; Zamami, Yoshito; Kawasaki, Hiromu; Takatori, Shingo

    2017-05-05

    Vascular adrenergic nerves mainly regulate the tone of blood vessels. Calcitonin gene-related peptide-containing (CGRPergic) vasodilator nerves also participate in the regulation of vascular tone. Furthermore, there are nitric oxide (NO)-containing (nitrergic) nerves, which include NO in blood vessels as vasodilator nerves, but it remains unclear whether nitrergic nerves participate in vascular regulation. The present study investigated the role of nitrergic nerves in vascular responses to spinal cord stimulation (SCS) and vasoactive agents in pithed rats. Wistar rats were anesthetized and pithed, and vasopressor responses to SCS and injections of norepinephrine were observed. To evaluate vasorelaxant responses, the BP was increased by a continuous infusion of methoxamine with hexamethonium to block autonomic outflow. After the elevated BP stabilized, SCS and injections of acetylcholine (ACh), sodium nitroprusside (SNP), and CGRP were intravenously administered. We then evaluated the effects of the NO synthase (NOS) inhibitor, N-ω-nitro-L-arginine methylester hydrochloride (L-NAME), on these vascular responses. Pressor responses to SCS and norepinephrine in pithed rats were enhanced by L-NAME, while the combined infusion of L-NAME and L-arginine had no effect on these responses. L-NAME infusion significantly increased the release of norepinephrine evoked by SCS. In pithed rats with artificially increased BP and L-NAME infusion, depressor response to ACh (except for 0.05nmol/kg) was suppressed and SNP (only 2nmol/kg) was enhanced. However, depressor responses to SCS and CGRP were similar to control responses. The present results suggest endogenous NO regulates vascular tone through endothelium function and inhibition of adrenergic neurotransmission, but not through CGRPergic nerves. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Nanofiber Nerve Guide for Peripheral Nerve Repair and Regeneration

    Science.gov (United States)

    2016-04-01

    1 Award Number: W81XWH-11-2-0047 TITLE: Nanofiber Nerve Guide for Peripheral Nerve Repair and Regeneration PRINCIPAL INVESTIGATOR: Ahmet Höke...TITLE AND SUBTITLE 5a. CONTRACT NUMBER W81XWH-11-2-0047 Nanofiber nerve guide for peripheral nerve repair and regeneration 5b. GRANT NUMBER...goal of this collaborative research project was to develop next generation engineered nerve guide conduits (NGCs) with aligned nanofibers and

  10. Radial nerve dysfunction

    Science.gov (United States)

    Neuropathy - radial nerve; Radial nerve palsy; Mononeuropathy ... Damage to one nerve group, such as the radial nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  11. Malignant peripheral nerve sheath tumor of the oculomotor nerve

    DEFF Research Database (Denmark)

    Kozic, D; Nagulic, M; Ostojic, J

    2006-01-01

    We present the short-term follow-up magnetic resonance (MR) studies and 1H-MR spectroscopy in a child with malignant peripheral nerve sheath tumor of the oculomotor nerve associated with other less aggressive cranial nerve schwannomas. The tumor revealed perineural extension and diffuse nerve...

  12. Scaffoldless tissue-engineered nerve conduit promotes peripheral nerve regeneration and functional recovery after tibial nerve injury in rats

    Institute of Scientific and Technical Information of China (English)

    Aaron M. Adams; Keith W. VanDusen; Tatiana Y. Kostrominova; Jacob P. Mertens; Lisa M. Larkin

    2017-01-01

    Damage to peripheral nerve tissue may cause loss of function in both the nerve and the targeted muscles it innervates. This study compared the repair capability of engineered nerve conduit (ENC), engineered fibroblast conduit (EFC), and autograft in a 10-mm tibial nerve gap. ENCs were fabricated utilizing primary fibroblasts and the nerve cells of rats on embryonic day 15 (E15). EFCs were fabricated utilizing primary fi-broblasts only. Following a 12-week recovery, nerve repair was assessed by measuring contractile properties in the medial gastrocnemius muscle, distal motor nerve conduction velocity in the lateral gastrocnemius, and histology of muscle and nerve. The autografts, ENCs and EFCs reestablished 96%, 87% and 84% of native distal motor nerve conduction velocity in the lateral gastrocnemius, 100%, 44% and 44% of native specific force of medical gastrocnemius, and 63%, 61% and 67% of native medial gastrocnemius mass, re-spectively. Histology of the repaired nerve revealed large axons in the autograft, larger but fewer axons in the ENC repair, and many smaller axons in the EFC repair. Muscle histology revealed similar muscle fiber cross-sectional areas among autograft, ENC and EFC repairs. In conclusion, both ENCs and EFCs promot-ed nerve regeneration in a 10-mm tibial nerve gap repair, suggesting that the E15 rat nerve cells may not be necessary for nerve regeneration, and EFC alone can suffice for peripheral nerve injury repair.

  13. Communication between radial nerve and medial cutaneous nerve of forearm

    Directory of Open Access Journals (Sweden)

    R R Marathe

    2010-01-01

    Full Text Available Radial nerve is usually a branch of the posterior cord of the brachial plexus. It innervates triceps, anconeous, brachialis, brachioradialis, extensor carpi radialis longus muscles and gives the posterior cutaneous nerve of the arm, lower lateral cutaneous nerve of arm, posterior cutaneous nerve of forearm; without exhibiting any communication with the medial cutaneous nerve of forearm or any other nerve. We report communication between the radial nerve and medial cutaneous nerve of forearm on the left side in a 58-year-old male cadaver. The right sided structures were found to be normal. Neurosurgeons should keep such variations in mind while performing the surgeries of axilla and upper arm.

  14. Synthesis and Biodistribution of Lipophilic Monocationic Gallium Radiopharmaceuticals Derived from N,N′-bis(3-aminopropyl)-N,N′-dimethylethylenediamine: Potential Agents for PET Myocardial Imaging with 68Ga

    Science.gov (United States)

    Hsiao, Yui-May; Mathias, Carla J.; Wey, Shiaw-Pyng; Fanwick, Phillip E.; Green, Mark A.

    2009-01-01

    Introduction In locations that lack nearby cyclotron facilities for radionuclide production, generator-based 68Ga-radiopharmaceuticals might have clinical utility for positron emission tomography (PET) studies of myocardial perfusion and other physiologic processes. Methods The lipophilic, monocationic 67Ga-labeled gallium chelates of five novel hexadentate bis(salicylaldimine) ligands, the bis(salicylaldimine), bis(3-methoxysalicylaldimine), bis(4-methoxysalicylaldimine), bis(6-methoxysalicylaldimine), and bis(4,6-dimethoxysalicylaldimine) of N,N′-bis(3-aminopropyl)-N,N′-dimethylethylenediamine (BAPDMEN), were prepared. The structure of the unlabeled [Ga(4-MeOsal)2BAPDMEN]+PF6− salt was determined by X-ray crystallography, and the biodistribution of each of the 67Ga-labeled gallium chelates determined in rats following i.v. administration and compared to the biodistribution of [86Rb]rubidium chloride. Results The [Ga(4-MeOsal)2BAPDMEN]+PF6− complex exhibits the expected pseudo-octahedral N4O22− coordination sphere about the Ga3+ center with a trans-disposition of the phenolate oxygen atoms. All five of the 67Ga-radiopharmaceuticals were found to afford the desired myocardial retention of the radiogallium. The [67/68Ga][Ga(3-MeOsal)2BAPDMEN]1+ radiopharmaceutical appears to have the best properties for myocardial imaging, exhibiting 2% of the injected dose in the heart at both 1-minute and 2-hours post-injection and very high heart/non-target ratios (heart/blood ratios of 7.6 ± 1.0 and 54 ± 10 at 1-min and 120-min, respectively; heart/liver ratios of 1.8 ± 0.4 and 39 ± 3 at 1-min and 120-min, respectively). Conclusions Most of these new agents, particularly [67/68Ga][Ga(3-MeOsal)2BAPDMEN]1+, would appear superior to previously reported bis(salicyaldimines) of N,N′-bis(3-aminopropyl)ethylenediamine as candidates for PET imaging of the heart with 68Ga. PMID:19181267

  15. Evaluation of a Recombinant Escherichia coli Strain that Uses the Sarin Simulant Isopropylmethylphosphonic Acid (IMPA) as a Sole Carbon and Phosphate Source

    Science.gov (United States)

    2016-04-01

    decontaminating a chemical stockpile scenario. All G- and V-agents hydrolyze in water relatively rapidly, so the metabolic focus may be of better use at the... Chemical Warfare Agents GA, GB, and VX: Implications for Public Protection. Environ. Health Perspect. 1994, 102 (1), 18–38. 2. Theriot, C.M...SUPPLEMENTARY NOTES 14. ABSTRACT: Chemical nerve agents consist of organophosphates that irreversibly inhibit the enzyme acetylcholinesterase within

  16. Antidotes and treatments for chemical warfare/terrorism agents: an evidence-based review.

    Science.gov (United States)

    Rodgers, G C; Condurache, C T

    2010-09-01

    This article reviews the evidence supporting the efficacy of antidotes used or recommended for the potential chemical warfare agents of most concern. Chemical warfare agents considered include cyanide, vesicants, pulmonary irritants such as chlorine and phosgene, and nerve agents. The strength of evidence for most antidotes is weak, highlighting the need for additional research in this area.

  17. Ulnar nerve dysfunction

    Science.gov (United States)

    Neuropathy - ulnar nerve; Ulnar nerve palsy; Mononeuropathy; Cubital tunnel syndrome ... Damage to one nerve group, such as the ulnar nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  18. A comparison of anesthetic agents and their effects on the response properties of the peripheral auditory system.

    Science.gov (United States)

    Dodd, F; Capranica, R R

    1992-10-01

    Anesthetic agents were compared in order to identify the most appropriate agent for use during surgery and electrophysiological recordings in the auditory system of the tokay gecko (Gekko gecko). Each agent was first screened for anesthetic and analgesic properties and, if found satisfactory, it was subsequently tested in electrophysiological recordings in the auditory nerve. The following anesthetic agents fulfilled our criteria and were selected for further screening: sodium pentobarbital (60 mg/kg); sodium pentobarbital (30 mg/kg) and oxymorphone (1 mg/kg); 3.2% isoflurane; ketamine (440 mg/kg) and oxymorphone (1 mg/kg). These agents were subsequently compared on the basis of their effect on standard response properties of auditory nerve fibers. Our results verified that different anesthetic agents can have significant effects on most of the parameters commonly used in describing the basic response properties of the auditory system in vertebrates. We therefore conclude from this study that the selection of an appropriate experimental protocol is critical and must take into consideration the effects of anesthesia on auditory responsiveness. In the tokay gecko, we recommend 3.2% isoflurane for general surgical procedures; and for electrophysiological recordings in the eighth nerve we recommend barbiturate anesthesia of appropriate dosage in combination if possible with an opioid agent to provide additional analgesic action.

  19. The First Experience of Triple Nerve Transfer in Proximal Radial Nerve Palsy.

    Science.gov (United States)

    Emamhadi, Mohammadreza; Andalib, Sasan

    2018-01-01

    Injury to distal portion of posterior cord of brachial plexus leads to palsy of radial and axillary nerves. Symptoms are usually motor deficits of the deltoid muscle; triceps brachii muscle; and extensor muscles of the wrist, thumb, and fingers. Tendon transfers, nerve grafts, and nerve transfers are options for surgical treatment of proximal radial nerve palsy to restore some motor functions. Tendon transfer is painful, requires a long immobilization, and decreases donor muscle strength; nevertheless, nerve transfer produces promising outcomes. We present a patient with proximal radial nerve palsy following a blunt injury undergoing triple nerve transfer. The patient was involved in a motorcycle accident with complete palsy of the radial and axillary nerves. After 6 months, on admission, he showed spontaneous recovery of axillary nerve palsy, but radial nerve palsy remained. We performed triple nerve transfer, fascicle of ulnar nerve to long head of the triceps branch of radial nerve, flexor digitorum superficialis branch of median nerve to extensor carpi radialis brevis branch of radial nerve, and flexor carpi radialis branch of median nerve to posterior interosseous nerve, for restoration of elbow, wrist, and finger extensions, respectively. Our experience confirmed functional elbow, wrist, and finger extensions in the patient. Triple nerve transfer restores functions of the upper limb in patients with debilitating radial nerve palsy after blunt injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. EPA Science Matters Newsletter: Chemical Warfare Agent Analytical Standards Facilitate Lab Testing (Published November 2013)

    Science.gov (United States)

    Learn about the EPA chemists' efforts to develop methods for detecting extremely low concentrations of nerve agents, such as sarin, VX, soman and cyclohexyl sarin, and the blister agent sulfur mustard.

  1. Protection Against Chemical Agent-Induced, Seizure-Related Neuronal Cell Death

    National Research Council Canada - National Science Library

    Ballough, Gerald P; Filbert, Margaret G

    2002-01-01

    .... While seizure-related brain damage can be prevented by administration of an anticonvulsant drug, battlefield conditions may preclude prompt administration of the convulsant antidote for nerve agents (CANA...

  2. One-stage human acellular nerve allograft reconstruction for digital nerve defects

    Directory of Open Access Journals (Sweden)

    Xue-yuan Li

    2015-01-01

    Full Text Available Human acellular nerve allografts have a wide range of donor origin and can effectively avoid nerve injury in the donor area. Very little is known about one-stage reconstruction of digital nerve defects. The present study observed the feasibility and effectiveness of human acellular nerve allograft in the reconstruction of < 5-cm digital nerve defects within 6 hours after injury. A total of 15 cases of nerve injury, combined with nerve defects in 18 digits from the Department of Emergency were enrolled in this study. After debridement, digital nerves were reconstructed using human acellular nerve allografts. The patients were followed up for 6-24 months after reconstruction. Mackinnon-Dellon static two-point discrimination results showed excellent and good rates of 89%. Semmes-Weinstein monofilament test demonstrated that light touch was normal, with an obvious improvement rate of 78%. These findings confirmed that human acellular nerve allograft for one-stage reconstruction of digital nerve defect after hand injury is feasible, which provides a novel trend for peripheral nerve reconstruction.

  3. Nerves and nerve endings in the skin of tropical cattle.

    Science.gov (United States)

    Amakiri, S F; Ozoya, S E; Ogunnaike, P O

    1978-01-01

    The nerves and nerve endings in the skin of tropical cattle were studied using histological and histochemical techniques. Many nerve trunks and fibres were present in the reticular and papillary dermis in both hairy and non-hairy skin sites. In non-hairy skin locations such as the muzzle and lower lip, encapsulated endings akin to Krause and Ruffini end bulbs, which arise from myelinated nerve trunks situated lower down the dermis were observed at the upper papillary layer level. Some fibre trunks seen at this level extended upwards to terminate within dermal papillae as bulb-shaped longitudinally lamellated Pacinian-type endings, while other onion-shaped lamellated nerve structures were located either within dermal papillae or near the dermo-epidermal area. Intraepidermal free-ending nerve fibres, appearing non-myelinated were observed in areas with thick epidermis. Intraepidermal free-ending nerve fibres, appearing non-myelinated were observed in areas with thick epidermis. On hairy skin sites, however, organized nerve endings or intraepidermal nerve endings were not readily identifiable.

  4. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  5. Nerve ultrasound shows subclinical peripheral nerve involvement in neurofibromatosis type 2.

    Science.gov (United States)

    Telleman, Johan A; Stellingwerff, Menno D; Brekelmans, Geert J; Visser, Leo H

    2018-02-01

    Neurofibromatosis type 2 (NF2) is mainly associated with central nervous system (CNS) tumors. Peripheral nerve involvement is described in symptomatic patients, but evidence of subclinical peripheral nerve involvement is scarce. We conducted a cross-sectional pilot study in 2 asymptomatic and 3 minimally symptomatic patients with NF2 to detect subclinical peripheral nerve involvement. Patients underwent clinical examination, nerve conduction studies (NCS), and high-resolution ultrasonography (HRUS). A total of 30 schwannomas were found, divided over 20 nerve segments (33.9% of all investigated nerve segments). All patients had at least 1 schwannoma. Schwannomas were identified with HRUS in 37% of clinically unaffected nerve segments and 50% of nerve segments with normal NCS findings. HRUS shows frequent subclinical peripheral nerve involvement in NF2. Clinicians should consider peripheral nerve involvement as a cause of weakness and sensory loss in the extremities in patients with this disease. Muscle Nerve 57: 312-316, 2018. © 2017 Wiley Periodicals, Inc.

  6. Polymeric Nerve Conduits with Contact Guidance Cues Used in Nerve Repair

    Institute of Scientific and Technical Information of China (English)

    G DAI; X NIU; J YIN

    2016-01-01

    In the modern life, the nerve injury frequently happens due to mechanical, chemical or thermal accidents. In the trivial injuries, the peripheral nerves can regenerate on their own; however, in most of the cases the clinical treatments are required, where relatively large nerve injury gaps are formed. Currently, the nerve repair can be accomplished by direct suture when the injury gap is not too large;while the autologous nerve graft working as the gold standard of peripheral nerve injury treatment for nerve injuries with larger gaps. However, the direct suture is limited by heavy tension at the suture sites, and the autologous nerve graft also has the drawbacks of donor site morbidity and insufifcient donor tissue. Recently, artiifcial nerve conduits have been developed as an alternative for clinical nerve repair to overcome the limitations associated with the above treatments. In order to further improve the efifciency of nerve conduits, various guidance cues are incorporated, including physical cues, biochemical signals, as well as support cells. First, this paper reviewed the contact guidance cues applied in nerve conduits, such as lumen ifllers, multi-channels and micro-patterns on the inner surface. Then, the paper focused on the polymeric nerve conduits with micro inner grooves. The polymeric nerve conduits were fabricated using the phase inversion-based ifber spinning techniques. The smart spinneret with grooved die was designed in the spinning platform, while different spinning conditions, including flow rates, air-gap distances, and polymer concentrations, were adjusted to investigate the inlfuence of fabrication conditions on the geometry of nerve conduits. The inner groove size in the nerve conduits can be precisely controlled in our hollow ifber spinning process, which can work as the efifcient contact guidance cue for nerve regeneration.

  7. A Laserterapia de baixa intensidade acelera a regeneração de nervos periféricos Low-power laser therapy accelerates peripheral nerves' regeneration

    Directory of Open Access Journals (Sweden)

    Cristina Endo

    2008-01-01

    Full Text Available Há evidências de que a terapia com o laser pode estimular a regeneração de nervos e esta hipótese foi testada em ratos. Uma lesão por esmagamento controlado foi produzida no nervo isquiático de 20 ratos Wistar, metade dos quais foram submetidos a irradiação efetiva com o laser de arseneto de gálio (AsGa e a outra metade a irradiação simulada, durante dez dias consecutivos, começando no primeiro dia pós-operatório. Os resultados foram avaliados com três semanas pela medida do índice funcional do isquiático (IFC em intervalos semanais e pela medida do número total de fibras nervosas e da densidade de fibras dos nervos, após o sacrifício dos animais na terceira semana, com o nível de significância de 5% (pThere are evidences that laser therapy may stimulate nerve regeneration and this hypothesis was tested in rats. A controlled crush injury was produced on the sciatic nerve of 20 Wistar rats, half of which submitted to effective Ga-As laser irradiation and the other half to simulated irradiation for 10 consecutive days beginning on the first postoperative day. Results were evaluated at three weeks postoperatively by measuring the sciatic functional index (SFI at weekly intervals and the total number of nerve fibers and nerve fiber density of the sciatic nerve at three weeks (p<0.05. The SFI progressively improved for both irradiated and control nerves (69% and 45%, respectively with a significant difference between them at two weeks (p=0.04. Nerve fiber density increased for the irradiated nerves and decreased for the control nerves, with significant differences between them (p=0.001. Low intensity therapeutic ultrasound accelerates nerve regeneration, as demonstrated with significance on the 21st postoperative day.

  8. Tissue-engineered spiral nerve guidance conduit for peripheral nerve regeneration.

    Science.gov (United States)

    Chang, Wei; Shah, Munish B; Lee, Paul; Yu, Xiaojun

    2018-06-01

    Recently in peripheral nerve regeneration, preclinical studies have shown that the use of nerve guidance conduits (NGCs) with multiple longitudinally channels and intra-luminal topography enhance the functional outcomes when bridging a nerve gap caused by traumatic injury. These features not only provide guidance cues for regenerating nerve, but also become the essential approaches for developing a novel NGC. In this study, a novel spiral NGC with aligned nanofibers and wrapped with an outer nanofibrous tube was first developed and investigated. Using the common rat sciatic 10-mm nerve defect model, the in vivo study showed that a novel spiral NGC (with and without inner nanofibers) increased the successful rate of nerve regeneration after 6 weeks recovery. Substantial improvements in nerve regeneration were achieved by combining the spiral NGC with inner nanofibers and outer nanofibrous tube, based on the results of walking track analysis, electrophysiology, nerve histological assessment, and gastrocnemius muscle measurement. This demonstrated that the novel spiral NGC with inner aligned nanofibers and wrapped with an outer nanofibrous tube provided a better environment for peripheral nerve regeneration than standard tubular NGCs. Results from this study will benefit for future NGC design to optimize tissue-engineering strategies for peripheral nerve regeneration. We developed a novel spiral nerve guidance conduit (NGC) with coated aligned nanofibers. The spiral structure increases surface area by 4.5 fold relative to a tubular NGC. Furthermore, the aligned nanofibers was coated on the spiral walls, providing cues for guiding neurite extension. Finally, the outside of spiral NGC was wrapped with randomly nanofibers to enhance mechanical strength that can stabilize the spiral NGC. Our nerve histological data have shown that the spiral NGC had 50% more myelinated axons than a tubular structure for nerve regeneration across a 10 mm gap in a rat sciatic nerve

  9. Sensation, mechanoreceptor, and nerve fiber function after nerve regeneration

    DEFF Research Database (Denmark)

    Krarup, Christian; Rosén, Birgitta; Boeckstyns, Michel

    2017-01-01

    Objective: Sensation is essential for recovery after peripheral nerve injury. However, the relationship between sensory modalities and function of regenerated fibers is uncertain. We have investigated the relationships between touch threshold, tactile gnosis, and mechanoreceptor and sensory fiber...... function after nerve regeneration. Methods: Twenty-one median or ulnar nerve lesions were repaired by a collagen nerve conduit or direct suture. Quantitative sensory hand function and sensory conduction studies by near-nerve technique, including tactile stimulation of mechanoreceptors, were followed for 2...... years, and results were compared to noninjured hands. Results: At both repair methods, touch thresholds at the finger tips recovered to 81 ± 3% and tactile gnosis only to 20 ± 4% (p nerve action potentials (SNAPs) remained dispersed and areas recovered to 23 ± 2...

  10. The role of great auricular-facial nerve neurorrhaphy in facial nerve damage

    OpenAIRE

    Sun, Yan; Liu, Limei; Han, Yuechen; Xu, Lei; Zhang, Daogong; Wang, Haibo

    2015-01-01

    Background: Facial nerve is easy to be damaged, and there are many reconstructive methods for facial nerve reconstructive, such as facial nerve end to end anastomosis, the great auricular nerve graft, the sural nerve graft, or hypoglossal-facial nerve anastomosis. However, there is still little study about great auricular-facial nerve neurorrhaphy. The aim of the present study was to identify the role of great auricular-facial nerve neurorrhaphy and the mechanism. Methods: Rat models of facia...

  11. The role of great auricular-facial nerve neurorrhaphy in facial nerve damage.

    Science.gov (United States)

    Sun, Yan; Liu, Limei; Han, Yuechen; Xu, Lei; Zhang, Daogong; Wang, Haibo

    2015-01-01

    Facial nerve is easy to be damaged, and there are many reconstructive methods for facial nerve reconstructive, such as facial nerve end to end anastomosis, the great auricular nerve graft, the sural nerve graft, or hypoglossal-facial nerve anastomosis. However, there is still little study about great auricular-facial nerve neurorrhaphy. The aim of the present study was to identify the role of great auricular-facial nerve neurorrhaphy and the mechanism. Rat models of facial nerve cut (FC), facial nerve end to end anastomosis (FF), facial-great auricular neurorrhaphy (FG), and control (Ctrl) were established. Apex nasi amesiality observation, electrophysiology and immunofluorescence assays were employed to investigate the function and mechanism. In apex nasi amesiality observation, it was found apex nasi amesiality of FG group was partly recovered. Additionally, electrophysiology and immunofluorescence assays revealed that facial-great auricular neurorrhaphy could transfer nerve impulse and express AChR which was better than facial nerve cut and worse than facial nerve end to end anastomosis. The present study indicated that great auricular-facial nerve neurorrhaphy is a substantial solution for facial lesion repair, as it is efficiently preventing facial muscles atrophy by generating neurotransmitter like ACh.

  12. Pinched Nerve

    Science.gov (United States)

    ... You are here Home » Disorders » All Disorders Pinched Nerve Information Page Pinched Nerve Information Page What research is being done? Within the NINDS research programs, pinched nerves are addressed primarily through studies associated with pain ...

  13. (67/68)Ga-labeling agent that liberates (67/68)Ga-NOTA-methionine by lysosomal proteolysis of parental low molecular weight polypeptides to reduce renal radioactivity levels.

    Science.gov (United States)

    Uehara, Tomoya; Rokugawa, Takemi; Kinoshita, Mai; Nemoto, Souki; Fransisco Lazaro, Guerra Gomez; Hanaoka, Hirofumi; Arano, Yasushi

    2014-11-19

    The renal localization of gallium-67 or gallium-68 ((67/68)Ga)-labeled low molecular weight (LMW) probes such as peptides and antibody fragments constitutes a problem in targeted imaging. Wu et al. previously showed that (67)Ga-labeled S-2-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid (SCN-Bz-NOTA)-conjugated methionine ((67)Ga-NOTA-Met) was rapidly excreted from the kidney in urine following lysosomal proteolysis of the parental (67)Ga-NOTA-Bz-SCN-disulfide-stabilized Fv fragment (Bioconjugate Chem., (1997) 8, 365-369). In the present study, a new (67/68)Ga-labeling reagent for LMW probes that liberates (67/68)Ga-NOTA-Met was designed, synthesized, and evaluated using longer-lived (67)Ga in order to reduce renal radioactivity levels. We employed a methionine-isoleucine (MI) dipeptide bond as the cleavable linkage. The amine residue of MI was coupled with SCN-Bz-NOTA for (67)Ga-labeling, while the carboxylic acid residue of MI was derivatized to maleimide for antibody conjugation in order to synthesize NOTA-MI-Mal. A Fab fragment of the anti-Her2 antibody was thiolated with iminothiolane, and NOTA-MI-Mal was conjugated with the antibody fragment by maleimide-thiol chemistry. The Fab fragment was also conjugated with SCN-Bz-NOTA (NOTA-Fab) for comparison. (67)Ga-NOTA-MI-Fab was obtained at radiochemical yields of over 95% and was stable in murine serum for 24 h. In the biodistribution study using normal mice, (67)Ga-NOTA-MI-Fab registered significantly lower renal radioactivity levels from 1 to 6 h postinjection than those of (67)Ga-NOTA-Fab. An analysis of urine samples obtained 6 h after the injection of (67)Ga-NOTA-MI-Fab showed that the majority of radioactivity was excreted as (67)Ga-NOTA-Met. In the biodistribution study using tumor-bearing mice, the tumor to kidney ratios of (67)Ga-NOTA-MI-Fab were 4 times higher (6 h postinjection) than those of (67)Ga-NOTA-Fab. Although further studies including the structure of radiometabolites and

  14. Is rivastigmine safe as pretreatment against nerve agents poisoning? A pharmacological, physiological and cognitive assessment in healthy young adult volunteers.

    Science.gov (United States)

    Lavon, Ophir; Eisenkraft, Arik; Blanca, Merav; Raveh, Lily; Ramaty, Erez; Krivoy, Amir; Atsmon, Jacob; Grauer, Ettie; Brandeis, Rachel

    2015-07-01

    Rivastigmine, a reversible cholinesterase inhibitor, approved as a remedy in Alzheimer's disease, was suggested as pretreatment against nerve agents poisoning. We evaluated the pharmacokinetic, pharmacodynamic, physiologic, cognitive and emotional effects of repeated rivastigmine in young healthy male adults, in a double blind, placebo controlled crossover trial. Three groups completed 3 treatment periods: 0, 1.5 and 3mg twice a day, for a total of 5 intakes. Parameters monitored were: vital signs, ECG, laboratory tests, sialometry, visual accommodation, inspiratory peak flow, and cognitive function tests. Adverse reactions were mild. Peak blood levels and peak cholinesterase inhibition increased with repeated intakes, and high variability and non-linear pharmacokinetics were demonstrated. In addition, two cognitive functions were affected (perceptual speed and dynamic tracking). The complicated pharmacological profile and the high inter-personal variability limit the potential use of rivastigmine as pretreatment for war fighters and first responders. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. ENERGÍA DE ENLACE DE EXCITONES EN POZOS CUÁNTICOS DE GaAs/Ga1-xAl xAs

    Directory of Open Access Journals (Sweden)

    Parménides Aristizábal

    2007-06-01

    Full Text Available El uso de las estructuras de baja dimensionalidad es un elemento tecnológico clave en la creación de nuevos dispositivos cuánticos funcionales de la siguiente generación de circuitos integrados electrónicos, fotónicos y espintrónicos y muchos otros dispositivos nanotecnológicos que son necesarios para la sociedad de la información del siglo XXI. Una de las propiedades ópticas más importante es la fotoluminiscencia producida por agentes tales como impurezas y excitones en pozos, hilos y puntos cuánticos de arseniuro de galio GaAs con dimensiones nanométricas bajo la influencia de campos eléctricos y magnéticos y presiones externas. Se presenta la energía de enlace para los tres primeros estados excitónicos en pozos cuánticos de GaAs/Ga1-xAl xAs describiendo el sistema por medio de la teoría cuántica, en la aproximación de masa efectiva y usando el método variacional.The use of low dimensional structures is a key technological element in the creation of new quantum functional devices in the development of the next generation of the electronic, photonic, and spintronic integrated circuits and many other nanoscaled devices that are necessary for the information society of 21st century. One of the most important optical properties is the photoluminescence produced by agents as impurities and excitons in GaAs quantum wells, wires, and dots with nanometric dimensions under the influence of electric and magnetic fields and external pressures. The binding energy for the first three excitonic states in GaAs/Ga1-xA1xAs quantum wells describing the system through quantum theory in the effective mass approximation and using the variational method is presented.

  16. Decontamination and Detoxification of Toxic Chemical Warfare Agents Using Polyurethane Sponges

    National Research Council Canada - National Science Library

    Gordon, Richard K; Gunduz, Alper T; Askins, LaTawnya Y; Strating, Simon J; Doctor, Bhupendra P; Clarkson, Edward D; Mitchelree, Larry W; Lukey, Brian; Railer, Roy; Schulz, Susan

    2003-01-01

    .... Another serious problem that may be encountered while caring for personnel contaminated with organophosphorus chemical warfare nerve agents is the possibility that there will be cross-contamination...

  17. Assessment of nerve regeneration across nerve allografts treated with tacrolimus.

    Science.gov (United States)

    Haisheng, Han; Songjie, Zuo; Xin, Li

    2008-01-01

    Although regeneration of nerve allotransplant is a major concern in the clinic, there have been few papers quantitatively assessing functional recovery of animals' nerve allografts in the long term. In this study, functional recovery, histopathological study, and immunohistochemistry changes of rat nerve allograft with FK506 were investigated up to 12 weeks without slaughtering. C57 and SD rats were used for transplantation. The donor's nerve was sliced and transplanted into the recipient. The sciatic nerve was epineurally sutured with 10-0 nylon. In total, 30 models of transplantation were performed and divided into 3 groups that were either treated with FK506 or not. Functional recovery of the grafted nerve was serially assessed by the pin click test, walking track analysis and electrophysiological evaluations. A histopathological study and immunohistochemistry study were done in the all of the models. Nerve allografts treated with FK506 have no immune rejection through 12 weeks. Sensibility had similarly improved in both isografts and allografts. There has been no difference in each graft. Walk track analysis demonstrates significant recovery of motor function of the nerve graft. No histological results of difference were found up to 12 weeks in each graft. In the rodent nerve graft model, FK506 prevented nerve allograft rejection across a major histocompatibility barrier. Sensory recovery seems to be superior to motor function. Nerve isograft and allograft treated with FK506 have no significant difference in function recovery, histopathological result, and immunohistochemistry changes.

  18. Effect of PACAP in Central and Peripheral Nerve Injuries

    Directory of Open Access Journals (Sweden)

    Andras Buki

    2012-07-01

    Full Text Available Pituitary adenylate cyclase activating polypeptide (PACAP is a bioactive peptide with diverse effects in the nervous system. In addition to its more classic role as a neuromodulator, PACAP functions as a neurotrophic factor. Several neurotrophic factors have been shown to play an important role in the endogenous response following both cerebral ischemia and traumatic brain injury and to be effective when given exogenously. A number of studies have shown the neuroprotective effect of PACAP in different models of ischemia, neurodegenerative diseases and retinal degeneration. The aim of this review is to summarize the findings on the neuroprotective potential of PACAP in models of different traumatic nerve injuries. Expression of endogenous PACAP and its specific PAC1 receptor is elevated in different parts of the central and peripheral nervous system after traumatic injuries. Some experiments demonstrate the protective effect of exogenous PACAP treatment in different traumatic brain injury models, in facial nerve and optic nerve trauma. The upregulation of endogenous PACAP and its receptors and the protective effect of exogenous PACAP after different central and peripheral nerve injuries show the important function of PACAP in neuronal regeneration indicating that PACAP may also be a promising therapeutic agent in injuries of the nervous system.

  19. Peripheral nerve regeneration through P(DLLA-epsilon-CL) nerve guides

    NARCIS (Netherlands)

    Den Dunnen, WFA; Meek, MF; Robinson, PH; Schakernraad, JM

    1998-01-01

    P(DLLA-epsilon-CL) nerve guides can be used perfectly for short nerve gaps in rats, and are even better than short autologous nerve grafts. The tube dimensions, such as the internal diameter and wall thickness, are very important for the final outcome of peripheral nerve regeneration, as well as the

  20. Electrophysiology of Cranial Nerve Testing: Spinal Accessory and Hypoglossal Nerves.

    Science.gov (United States)

    Stino, Amro M; Smith, Benn E

    2018-01-01

    Multiple techniques have been developed for the electrodiagnostic evaluation of cranial nerves XI and XII. Each of these carries both benefits and limitations, with more techniques and data being available in the literature for spinal accessory than hypoglossal nerve evaluation. Spinal accessory and hypoglossal neuropathy are relatively uncommon cranial mononeuropathies that may be evaluated in the outpatient electrodiagnostic laboratory setting. A review of available literature using PubMed was conducted regarding electrodiagnostic technique in the evaluation of spinal accessory and hypoglossal nerves searching for both routine nerve conduction studies and repetitive nerve conduction studies. The review provided herein provides a resource by which clinical neurophysiologists may develop and implement clinical and research protocols for the evaluation of both of these lower cranial nerves in the outpatient setting.

  1. Mirror Neurons, Embodied Cognitive Agents and Imitation Learning

    Czech Academy of Sciences Publication Activity Database

    Wiedermann, Jiří

    2003-01-01

    Roč. 22, č. 6 (2003), s. 545-559 ISSN 1335-9150 R&D Projects: GA ČR GA201/02/1456 Institutional research plan: CEZ:AV0Z1030915 Keywords : complete agents * mirror neurons * embodied cognition * imitation learning * sensorimotor control Subject RIV: BA - General Mathematics Impact factor: 0.254, year: 2003 http://www.cai.sk/ojs/index.php/cai/article/view/468

  2. Evaluation of Morphological and Functional Nerve Recovery of Rat Sciatic Nerve with a Hyaff11-Based Nerve Guide

    Directory of Open Access Journals (Sweden)

    K. Jansen

    2006-01-01

    Full Text Available Application of a Hyaff11-based nerve guide was studied in rats. Functional tests were performed to study motor nerve recovery. A withdrawal reflex test was performed to test sensory recovery. Morphology was studied by means of histology on explanted tissue samples. Motor nerve recovery was established within 7 weeks. Hereafter, some behavioral parameters like alternating steps showed an increase in occurence, while others remained stable. Sensory function was observed within the 7 weeks time frame. Nerve tissue had bridged the 10-mm gap within 7 weeks. The average nerve fiber surface area increased significantly in time. In situ degradation of the nerve conduit was fully going on at week 7 and tubes had collapsed by then. At weeks 15 and 21, the knitted tube wall structure was completely surrounded by macrophages and giant cells, and matrix was penetrating the tube wall. We conclude that a Hyaff11-based nerve guide can be used to bridge short peripheral nerve defects in rat. However, adaptations need to be made.

  3. [Facial nerve neurinomas].

    Science.gov (United States)

    Sokołowski, Jacek; Bartoszewicz, Robert; Morawski, Krzysztof; Jamróz, Barbara; Niemczyk, Kazimierz

    2013-01-01

    Evaluation of diagnostic, surgical technique, treatment results facial nerve neurinomas and its comparison with literature was the main purpose of this study. Seven cases of patients (2005-2011) with facial nerve schwannomas were included to retrospective analysis in the Department of Otolaryngology, Medical University of Warsaw. All patients were assessed with history of the disease, physical examination, hearing tests, computed tomography and/or magnetic resonance imaging, electronystagmography. Cases were observed in the direction of potential complications and recurrences. Neurinoma of the facial nerve occurred in the vertical segment (n=2), facial nerve geniculum (n=1) and the internal auditory canal (n=4). The symptoms observed in patients were analyzed: facial nerve paresis (n=3), hearing loss (n=2), dizziness (n=1). Magnetic resonance imaging and computed tomography allowed to confirm the presence of the tumor and to assess its staging. Schwannoma of the facial nerve has been surgically removed using the middle fossa approach (n=5) and by antromastoidectomy (n=2). Anatomical continuity of the facial nerve was achieved in 3 cases. In the twelve months after surgery, facial nerve paresis was rated at level II-III° HB. There was no recurrence of the tumor in radiological observation. Facial nerve neurinoma is a rare tumor. Currently surgical techniques allow in most cases, the radical removing of the lesion and reconstruction of the VII nerve function. The rate of recurrence is low. A tumor of the facial nerve should be considered in the differential diagnosis of nerve VII paresis. Copyright © 2013 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  4. Improved InGaN/GaN quantum wells on treated GaN template with a Ga-rich GaN interlayer

    International Nuclear Information System (INIS)

    Fang, Zhilai; Shen, Xiyang; Wu, Zhengyuan; Zhang, Tong-Yi

    2015-01-01

    Treated GaN template was achieved by in situ droplet epitaxy of a Ga-rich GaN interlayer on the conventional GaN template. InGaN/GaN quantum wells (QWs) were grown on the conventional and treated GaN templates under the same growth conditions and then comprehensively characterized. The indium homogeneity in the InGaN layers and the interface sharpness between InGaN and GaN layers of the InGaN/GaN QWs on the treated GaN template were significantly improved. The emission intensity from the InGaN/GaN QWs on the treated GaN template was enhanced by 20% than that on the conventional GaN template, which was attributed to the strain reduction and the improvement in crystalline quality. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Use of superficial peroneal nerve graft for treating peripheral nerve injuries

    Directory of Open Access Journals (Sweden)

    Samuel Ribak

    2016-02-01

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the clinical results from treating chronic peripheral nerve injuries using the superficial peroneal nerve as a graft donor source. METHODS: This was a study on eleven patients with peripheral nerve injuries in the upper limbs that were treated with grafts from the sensitive branch of the superficial peroneal nerve. The mean time interval between the dates of the injury and surgery was 93 days. The ulnar nerve was injured in eight cases and the median nerve in six. There were three cases of injury to both nerves. In the surgery, a longitudinal incision was made on the anterolateral face of the ankle, thus viewing the superficial peroneal nerve, which was located anteriorly to the extensor digitorum longus muscle. Proximally, the deep fascia between the extensor digitorum longus and the peroneal longus muscles was dissected. Next, the motor branch of the short peroneal muscle (one of the branches of the superficial peroneal nerve was identified. The proximal limit of the sensitive branch was found at this point. RESULTS: The average space between the nerve stumps was 3.8 cm. The average length of the grafts was 16.44 cm. The number of segments used was two to four cables. In evaluating the recovery of sensitivity, 27.2% evolved to S2+, 54.5% to S3 and 18.1% to S3+. Regarding motor recovery, 72.7% presented grade 4 and 27.2% grade 3. There was no motor deficit in the donor area. A sensitive deficit in the lateral dorsal region of the ankle and the dorsal region of the foot was observed. None of the patients presented complaints in relation to walking. CONCLUSIONS: Use of the superficial peroneal nerve as a graft source for treating peripheral nerve injuries is safe and provides good clinical results similar to those from other nerve graft sources.

  6. Delayed peripheral nerve repair: methods, including surgical 'cross-bridging' to promote nerve regeneration.

    Science.gov (United States)

    Gordon, Tessa; Eva, Placheta; Borschel, Gregory H

    2015-10-01

    Despite the capacity of Schwann cells to support peripheral nerve regeneration, functional recovery after nerve injuries is frequently poor, especially for proximal injuries that require regenerating axons to grow over long distances to reinnervate distal targets. Nerve transfers, where small fascicles from an adjacent intact nerve are coapted to the nerve stump of a nearby denervated muscle, allow for functional return but at the expense of reduced numbers of innervating nerves. A 1-hour period of 20 Hz electrical nerve stimulation via electrodes proximal to an injury site accelerates axon outgrowth to hasten target reinnervation in rats and humans, even after delayed surgery. A novel strategy of enticing donor axons from an otherwise intact nerve to grow through small nerve grafts (cross-bridges) into a denervated nerve stump, promotes improved axon regeneration after delayed nerve repair. The efficacy of this technique has been demonstrated in a rat model and is now in clinical use in patients undergoing cross-face nerve grafting for facial paralysis. In conclusion, brief electrical stimulation, combined with the surgical technique of promoting the regeneration of some donor axons to 'protect' chronically denervated Schwann cells, improves nerve regeneration and, in turn, functional outcomes in the management of peripheral nerve injuries.

  7. Enhanced Peroxide Resistance of In Vitro Mutagenized Fluorideresistant Klebsiella pneumoniae Ureases for Catalytic Buffering of Agent Decontamination Reactions

    National Research Council Canada - National Science Library

    Fry, Ilona J; DeFrank, Joseph J

    2004-01-01

    ...) and oxidative surety agent decontamination technologies. Ammonia production from urea by urease neutralizes the production of Oalkylphosphonic acids resulting from the hydrolysis of Nerve agents such as Sarin and VX...

  8. Sensory nerve function and auto-mutilation after reconstruction of various gap lengths with nerve guides and autologous nerve grafts

    NARCIS (Netherlands)

    den Dunnen, WFA; Meek, MF

    The aim of this study was to evaluate sensory nerve recovery and auto-mutilation after reconstruction of various lengths of nerve gaps in the sciatic nerve of the rat, using different techniques. Group 4, in which the longest nerve gap (15 mm) was reconstructed with a thin-walled

  9. A rat model of nerve agent exposure applicable to the pediatric population: The anticonvulsant efficacies of atropine and GluK1 antagonists

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Steven L., E-mail: stevenmiller17@gmail.com [Department of Anatomy, Physiology, and Genetics, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Program in Neuroscience, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Aroniadou-Anderjaska, Vassiliki, E-mail: vanderjaska@usuhs.edu [Department of Anatomy, Physiology, and Genetics, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Department of Psychiatry, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Program in Neuroscience, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Figueiredo, Taiza H., E-mail: taiza.figueiredo.ctr@usuhs.edu [Department of Anatomy, Physiology, and Genetics, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Prager, Eric M., E-mail: eric.prager683@gmail.com [Department of Anatomy, Physiology, and Genetics, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Program in Neuroscience, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Almeida-Suhett, Camila P., E-mail: camilapalmeida@gmail.com [Department of Anatomy, Physiology, and Genetics, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Program in Neuroscience, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814 (United States); Apland, James P., E-mail: james.p.apland.civ@mail.mil [Neurotoxicology Branch, U.S. Army Medical Research Institute of Chemical Defense, Aberdeen Proving Ground, MD 21010 (United States); and others

    2015-04-15

    Inhibition of acetylcholinesterase (AChE) after nerve agent exposure induces status epilepticus (SE), which causes brain damage or death. The development of countermeasures appropriate for the pediatric population requires testing of anticonvulsant treatments in immature animals. In the present study, exposure of 21-day-old (P21) rats to different doses of soman, followed by probit analysis, produced an LD{sub 50} of 62 μg/kg. The onset of behaviorally-observed SE was accompanied by a dramatic decrease in brain AChE activity; rats who did not develop SE had significantly less reduction of AChE activity in the basolateral amygdala than rats who developed SE. Atropine sulfate (ATS) at 2 mg/kg, administered 20 min after soman exposure (1.2 × LD{sub 50}), terminated seizures. ATS at 0.5 mg/kg, given along with an oxime within 1 min after exposure, allowed testing of anticonvulsants at delayed time-points. The AMPA/GluK1 receptor antagonist LY293558, or the specific GluK1 antagonist UBP302, administered 1 h post-exposure, terminated SE. There were no degenerating neurons in soman-exposed P21 rats, but both the amygdala and the hippocampus were smaller than in control rats at 30 and 90 days post-exposure; this pathology was not present in rats treated with LY293558. Behavioral deficits present at 30 days post-exposure, were also prevented by LY293558 treatment. Thus, in immature animals, a single injection of atropine is sufficient to halt nerve agent-induced seizures, if administered timely. Testing anticonvulsants at delayed time-points requires early administration of ATS at a low dose, sufficient to counteract only peripheral toxicity. LY293558 administered 1 h post-exposure, prevents brain pathology and behavioral deficits. - Highlights: • The LD{sub 50} of soman was determined in postnatal-day-21 rats. • Rats with no seizures after 1.2XLD{sub 50} soman had less reduction of AChE in the amygdala. • Atropine sulfate (ATS) at 2 mg/kg, given at 20 min after

  10. A rat model of nerve agent exposure applicable to the pediatric population: The anticonvulsant efficacies of atropine and GluK1 antagonists

    International Nuclear Information System (INIS)

    Miller, Steven L.; Aroniadou-Anderjaska, Vassiliki; Figueiredo, Taiza H.; Prager, Eric M.; Almeida-Suhett, Camila P.; Apland, James P.

    2015-01-01

    Inhibition of acetylcholinesterase (AChE) after nerve agent exposure induces status epilepticus (SE), which causes brain damage or death. The development of countermeasures appropriate for the pediatric population requires testing of anticonvulsant treatments in immature animals. In the present study, exposure of 21-day-old (P21) rats to different doses of soman, followed by probit analysis, produced an LD 50 of 62 μg/kg. The onset of behaviorally-observed SE was accompanied by a dramatic decrease in brain AChE activity; rats who did not develop SE had significantly less reduction of AChE activity in the basolateral amygdala than rats who developed SE. Atropine sulfate (ATS) at 2 mg/kg, administered 20 min after soman exposure (1.2 × LD 50 ), terminated seizures. ATS at 0.5 mg/kg, given along with an oxime within 1 min after exposure, allowed testing of anticonvulsants at delayed time-points. The AMPA/GluK1 receptor antagonist LY293558, or the specific GluK1 antagonist UBP302, administered 1 h post-exposure, terminated SE. There were no degenerating neurons in soman-exposed P21 rats, but both the amygdala and the hippocampus were smaller than in control rats at 30 and 90 days post-exposure; this pathology was not present in rats treated with LY293558. Behavioral deficits present at 30 days post-exposure, were also prevented by LY293558 treatment. Thus, in immature animals, a single injection of atropine is sufficient to halt nerve agent-induced seizures, if administered timely. Testing anticonvulsants at delayed time-points requires early administration of ATS at a low dose, sufficient to counteract only peripheral toxicity. LY293558 administered 1 h post-exposure, prevents brain pathology and behavioral deficits. - Highlights: • The LD 50 of soman was determined in postnatal-day-21 rats. • Rats with no seizures after 1.2XLD 50 soman had less reduction of AChE in the amygdala. • Atropine sulfate (ATS) at 2 mg/kg, given at 20 min after soman, blocked

  11. Tissue-engineered rhesus monkey nerve grafts for the repair of long ulnar nerve defects: similar outcomes to autologous nerve grafts

    Directory of Open Access Journals (Sweden)

    Chang-qing Jiang

    2016-01-01

    Full Text Available Acellular nerve allografts can help preserve normal nerve structure and extracellular matrix composition. These allografts have low immunogenicity and are more readily available than autologous nerves for the repair of long-segment peripheral nerve defects. In this study, we repaired a 40-mm ulnar nerve defect in rhesus monkeys with tissue-engineered peripheral nerve, and compared the outcome with that of autograft. The graft was prepared using a chemical extract from adult rhesus monkeys and seeded with allogeneic Schwann cells. Pathomorphology, electromyogram and immunohistochemistry findings revealed the absence of palmar erosion or ulcers, and that the morphology and elasticity of the hypothenar eminence were normal 5 months postoperatively. There were no significant differences in the mean peak compound muscle action potential, the mean nerve conduction velocity, or the number of neurofilaments between the experimental and control groups. However, outcome was significantly better in the experimental group than in the blank group. These findings suggest that chemically extracted allogeneic nerve seeded with autologous Schwann cells can repair 40-mm ulnar nerve defects in the rhesus monkey. The outcomes are similar to those obtained with autologous nerve graft.

  12. Tissue-engineered rhesus monkey nerve gratfs for the repair of long ulnar nerve defects:similar outcomes to autologous nerve gratfs

    Institute of Scientific and Technical Information of China (English)

    Chang-qing Jiang; Jun Hu; Jian-ping Xiang; Jia-kai Zhu; Xiao-lin Liu; Peng Luo

    2016-01-01

    Acellular nerve allogratfs can help preserve normal nerve structure and extracellular matrix composition. These allogratfs have low immu-nogenicity and are more readily available than autologous nerves for the repair of long-segment peripheral nerve defects. In this study, we repaired a 40-mm ulnar nerve defect in rhesus monkeys with tissue-engineered peripheral nerve, and compared the outcome with that of autogratf. The gratf was prepared using a chemical extract from adult rhesus monkeys and seeded with allogeneic Schwann cells. Pathomo-rphology, electromyogram and immunohistochemistry ifndings revealed the absence of palmar erosion or ulcers, and that the morphology and elasticity of the hypothenar eminence were normal 5 months postoperatively. There were no signiifcant differences in the mean peak compound muscle action potential, the mean nerve conduction velocity, or the number of neuroiflaments between the experimental and control groups. However, outcome was signiifcantly better in the experimental group than in the blank group. These ifndings suggest that chemically extracted allogeneic nerve seeded with autologous Schwann cells can repair 40-mm ulnar nerve defects in the rhesus monkey. The outcomes are similar to those obtained with autologous nerve gratf.

  13. Optic nerve oxygenation

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Pedersen, Daniella Bach; Jensen, Peter Koch

    2005-01-01

    The oxygen tension of the optic nerve is regulated by the intraocular pressure and systemic blood pressure, the resistance in the blood vessels and oxygen consumption of the tissue. The oxygen tension is autoregulated and moderate changes in intraocular pressure or blood pressure do not affect...... the optic nerve oxygen tension. If the intraocular pressure is increased above 40 mmHg or the ocular perfusion pressure decreased below 50 mmHg the autoregulation is overwhelmed and the optic nerve becomes hypoxic. A disturbance in oxidative metabolism in the cytochromes of the optic nerve can be seen...... at similar levels of perfusion pressure. The levels of perfusion pressure that lead to optic nerve hypoxia in the laboratory correspond remarkably well to the levels that increase the risk of glaucomatous optic nerve atrophy in human glaucoma patients. The risk for progressive optic nerve atrophy in human...

  14. Impact of ambient gases on the mechanism of [Cs8Nb6O19]-promoted nerve-agent decomposition.

    Science.gov (United States)

    Kaledin, Alexey L; Driscoll, Darren M; Troya, Diego; Collins-Wildman, Daniel L; Hill, Craig L; Morris, John R; Musaev, Djamaladdin G

    2018-02-28

    The impact of ambient gas molecules (X), NO 2 , CO 2 and SO 2 on the structure, stability and decontamination activity of Cs 8 Nb 6 O 19 polyoxometalate was studied computationally and experimentally. It was found that Cs 8 Nb 6 O 19 absorbs these molecules more strongly than it adsorbs water and Sarin (GB) and that these interactions hinder nerve agent decontamination. The impacts of diamagnetic CO 2 and SO 2 molecules on polyoxoniobate Cs 8 Nb 6 O 19 were fundamentally different from that of NO 2 radical. At ambient temperatures, weak coordination of the first NO 2 radical to Cs 8 Nb 6 O 19 conferred partial radical character on the polyoxoniobate and promoted stronger coordination of the second NO 2 adsorbent to form a stable diamagnetic Cs 8 Nb 6 O 19 /(NO 2 ) 2 species. Moreover, at low temperatures, NO 2 radicals formed stable dinitrogen tetraoxide (N 2 O 4 ) that weakly interacted with Cs 8 Nb 6 O 19 . It was found that both in the absence and presence of ambient gas molecules, GB decontamination by the Cs 8 Nb 6 O 19 species proceeds via general base hydrolysis involving: (a) the adsorption of water and the nerve agent on Cs 8 Nb 6 O 19 /(X), (b) concerted hydrolysis of a water molecule on a basic oxygen atom of the polyoxoniobate and nucleophilic addition of the nascent OH group to the phosphorus center of Sarin, and (c) rapid reorganization of the formed pentacoordinated-phosphorus intermediate, followed by dissociation of either HF or isopropanol and formation of POM-bound isopropyl methyl phosphonic acid (i-MPA) or methyl phosphonofluoridic acid (MPFA), respectively. The presence of the ambient gas molecules increases the energy of the intermediate stationary points relative to the asymptote of the reactants and slightly increases the hydrolysis barrier. These changes closely correlate with the Cs 8 Nb 6 O 19 -X complexation energy. The most energetically stable intermediates of the GB hydrolysis and decontamination reaction were found to be Cs 8 Nb 6 O

  15. The Role of Nerve Exploration in Supracondylar Humerus Fracture in Children with Nerve Injury

    Directory of Open Access Journals (Sweden)

    Anuar RIM

    2015-11-01

    Full Text Available The supracondylar humerus fracture (SCHF in children is common and can be complicated with nerve injury either primarily immediate post-trauma or secondarily posttreatment. The concept of neurapraxic nerve injury makes most surgeons choose to ‘watch and see’ the nerve recovery before deciding second surgery if the nerve does not recover. We report three cases of nerve injury in SCHF, all of which underwent nerve exploration for different reasons. Early reduction in the Casualty is important to release the nerve tension before transferring the patient to the operation room. If close reduction fails, we proceed to explore the nerve together with open reduction of the fracture. In iatrogenic nerve injury, we recommend nerve exploration to determine the surgical procedure that is causing the injury. Primary nerve exploration will allow early assessment of the injured nerve and minimize subsequent surgery.

  16. Novel Nucleophilic Compounds with Oxime Group as Reactivators of Paraoxon-Inhibited Cholinesterases

    Czech Academy of Sciences Publication Activity Database

    Musilová, L.; Jun, D.; Paleček, J.; Církva, Vladimír; Musílek, K.; Paar, M.; Hrabinová, M.; Pohanka, M.; Kuca, K.

    2010-01-01

    Roč. 7, č. 4 (2010), s. 260-264 ISSN 1570-1808 Grant - others:GA MO(CZ) OVUOFVZ200902 Program:OV Institutional research plan: CEZ:AV0Z40720504 Keywords : acetylcholinesterase * butyrylcholinesterase * nerve agent Subject RIV: CC - Organic Chemistry Impact factor: 0.668, year: 2010

  17. Poly(DL-lactide-epsilon-caprolactone) nerve guides perform better than autologous nerve grafts

    NARCIS (Netherlands)

    DenDunnen, WFA; VanderLei, B; Schakenraad, JM; Stokroos, [No Value; Blaauw, E; Pennings, AJ; Robinson, PH; Bartels, H.

    1996-01-01

    The aim of this study was to compare the speed and quality of nerve regeneration after reconstruction using a biodegradable nerve guide or an autologous nerve graft. We evaluated nerve regeneration using light microscopy, transmission electron microscopy and morphometric analysis. Nerve regeneration

  18. Neural stem cells enhance nerve regeneration after sciatic nerve injury in rats.

    Science.gov (United States)

    Xu, Lin; Zhou, Shuai; Feng, Guo-Ying; Zhang, Lu-Ping; Zhao, Dong-Mei; Sun, Yi; Liu, Qian; Huang, Fei

    2012-10-01

    With the development of tissue engineering and the shortage of autologous nerve grafts in nerve reconstruction, cell transplantation in a conduit is an alternative strategy to improve nerve regeneration. The present study evaluated the effects and mechanism of brain-derived neural stem cells (NSCs) on sciatic nerve injury in rats. At the transection of the sciatic nerve, a 10-mm gap between the nerve stumps was bridged with a silicon conduit filled with 5 × 10(5) NSCs. In control experiments, the conduit was filled with nerve growth factor (NGF) or normal saline (NS). The functional and morphological properties of regenerated nerves were investigated, and expression of hepatocyte growth factor (HGF) and NGF was measured. One week later, there was no connection through the conduit. Four or eight weeks later, fibrous connections were evident between the proximal and distal segments. Motor function was revealed by measurement of the sciatic functional index (SFI) and sciatic nerve conduction velocity (NCV). Functional recovery in the NSC and NGF groups was significantly more advanced than that in the NS group. NSCs showed significant improvement in axon myelination of the regenerated nerves. Expression of NGF and HGF in the injured sciatic nerve was significantly lower in the NS group than in the NSCs and NGF groups. These results and other advantages of NSCs, such as ease of harvest and relative abundance, suggest that NSCs could be used clinically to enhance peripheral nerve repair.

  19. Using Eggshell Membrane as Nerve Guide Channels in Peripheral Nerve Regeneration

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Farjah

    2013-08-01

    Full Text Available Objective(s:  The aim of this study was to evaluate the final outcome of nerve regeneration across the eggsell membrane (ESM tube conduit in comparison with autograft. Materials and Methods: Thirty adult male rats (250-300 g were randomized into (1 ESM conduit, (2 autograft, and (3 sham surgery groups. The eggs submerged in 5% acetic acid. The decalcifying membranes were cut into four pieces, rotated over the teflon mandrel and dried at   37°C. The left sciatic nerve was surgically cut. A 10-mm nerve segment was cut and removed. In the ESM group, the proximal and distal cut ends of the sciatic nerve were telescoped into the nerve guides. In the autograft group, the 10 mm nerve segment was reversed and used as an autologous nerve graft. All animals were evaluated by sciatic functional index (SFI and electrophysiology testing.  Results:The improvement in SFI from the first to the last evalution in ESM and autograft groups were evaluated. On days 49 and 60 post-operation, the mean SFI of ESM group was significantly greater than the autograft group (P 0.05. Conclusion:These findings demonstrate that ESM effectively enhances nerve regeneration and promotes functional recovery in injured sciatic nerve of rat.

  20. Autoregulation of neuromuscular transmission by nerve terminals. Annual report, 1 July 1983-1 July 1984

    Energy Technology Data Exchange (ETDEWEB)

    Bierkamper, G.G.

    1984-09-01

    The objective of this project is to investigate three mechanisms through which acetycholine (ACh) release may be modulated prejunctionally at the motor nerve terminal of skeletal muscle: (1) prejunctional cholinoceptor regulation of ACh release, (2) modulation of ACh release through preconditioning patterns of nerve stimulation, and (3) precursor control of ACh release. Neuromuscular transmission has been assessed in the vascular perfused rat phrenic nerve-diaphragm preparation (VPRH) by measuring the release of ACh directly by radioenzymatic assay or by chemiluminescence assay, and indirectly by intracellular recordings and by force of contradiction (FC) measurements. Additional experiments have been done on rat sciatic nerve in order to examine the axonal transport of nicotinic binding sites. The mouse hemidiahragm preparation has been used to study antidromic activity (backfiring) in the phrenic nerve in the presence of an anticholinesterase agent. The data resulting from the project support the concept that the nerve terminal possesses local mechanism for modulating ACh release. Attempts have been made to understand the normal function of these mechanisms and then to explore their activity under demanding physological conditions, drug exposure, and in the presence of acetylcholinesterase (AChE) inhibitors.

  1. An analysis of facial nerve function in irradiated and unirradiated facial nerve grafts

    International Nuclear Information System (INIS)

    Brown, Paul D.; Eshleman, Jeffrey S.; Foote, Robert L.; Strome, Scott E.

    2000-01-01

    Purpose: The effect of high-dose radiation therapy on facial nerve grafts is controversial. Some authors believe radiotherapy is so detrimental to the outcome of facial nerve graft function that dynamic or static slings should be performed instead of facial nerve grafts in all patients who are to receive postoperative radiation therapy. Unfortunately, the facial function achieved with dynamic and static slings is almost always inferior to that after facial nerve grafts. In this retrospective study, we compared facial nerve function in irradiated and unirradiated nerve grafts. Methods and Materials: The medical records of 818 patients with neoplasms involving the parotid gland who received treatment between 1974 and 1997 were reviewed, of whom 66 underwent facial nerve grafting. Fourteen patients who died or had a recurrence less than a year after their facial nerve graft were excluded. The median follow-up for the remaining 52 patients was 10.6 years. Cable nerve grafts were performed in 50 patients and direct anastomoses of the facial nerve in two. Facial nerve function was scored by means of the House-Brackmann (H-B) facial grading system. Twenty-eight of the 52 patients received postoperative radiotherapy. The median time from nerve grafting to start of radiotherapy was 5.1 weeks. The median and mean doses of radiation were 6000 and 6033 cGy, respectively, for the irradiated grafts. One patient received preoperative radiotherapy to a total dose of 5000 cGy in 25 fractions and underwent surgery 1 month after the completion of radiotherapy. This patient was placed, by convention, in the irradiated facial nerve graft cohort. Results: Potential prognostic factors for facial nerve function such as age, gender, extent of surgery at the time of nerve grafting, preoperative facial nerve palsy, duration of preoperative palsy if present, or number of previous operations in the parotid bed were relatively well balanced between irradiated and unirradiated patients. However

  2. Semi-continuous high speed gas analysis of generated vapors of chemical warfare agents

    NARCIS (Netherlands)

    Trap, H.C.; Langenberg, J.P.

    1999-01-01

    A method is presented for the continuous analysis of generated vapors of the nerve agents soman and satin and the blistering agent sulfur mustard. By using a gas sampling valve and a very short (15 cm) column connected to an on-column injector with a 'standard length' column, the system can either

  3. Optic Nerve Imaging

    Science.gov (United States)

    ... News About Us Donate In This Section Optic Nerve Imaging email Send this article to a friend ... measurements of nerve fiber damage (or loss). The Nerve Fiber Analyzer (GDx) uses laser light to measure ...

  4. POROSITY OF THE WALL OF A NEUROLAC (R) NERVE CONDUIT HAMPERS NERVE REGENERATION

    NARCIS (Netherlands)

    Meek, Marcel F.; Den Dunnen, Wilfred F. A.

    2009-01-01

    One way to improve nerve regeneration and bridge longer nerve gaps may be the use of semipermeable/porous conduits. With porosity less biomaterial is used for the nerve conduit. We evaluated the short-term effects of porous Neurolac (R) nerve conduits for in vivo peripheral nerve regeneration. In 10

  5. Complement components of nerve regeneration conditioned fluid influence the microenvironment of nerve regeneration

    Directory of Open Access Journals (Sweden)

    Guang-shuai Li

    2016-01-01

    Full Text Available Nerve regeneration conditioned fluid is secreted by nerve stumps inside a nerve regeneration chamber. A better understanding of the proteinogram of nerve regeneration conditioned fluid can provide evidence for studying the role of the microenvironment in peripheral nerve regeneration. In this study, we used cylindrical silicone tubes as the nerve regeneration chamber model for the repair of injured rat sciatic nerve. Isobaric tags for relative and absolute quantitation proteomics technology and western blot analysis confirmed that there were more than 10 complement components (complement factor I, C1q-A, C1q-B, C2, C3, C4, C5, C7, C8ß and complement factor D in the nerve regeneration conditioned fluid and each varied at different time points. These findings suggest that all these complement components have a functional role in nerve regeneration.

  6. Delayed peripheral nerve repair: methods, including surgical ?cross-bridging? to promote nerve regeneration

    OpenAIRE

    Gordon, Tessa; Eva, Placheta; Borschel, Gregory H.

    2015-01-01

    Despite the capacity of Schwann cells to support peripheral nerve regeneration, functional recovery after nerve injuries is frequently poor, especially for proximal injuries that require regenerating axons to grow over long distances to reinnervate distal targets. Nerve transfers, where small fascicles from an adjacent intact nerve are coapted to the nerve stump of a nearby denervated muscle, allow for functional return but at the expense of reduced numbers of innervating nerves. A 1-hour per...

  7. Electrophysiology of Cranial Nerve Testing: Trigeminal and Facial Nerves.

    Science.gov (United States)

    Muzyka, Iryna M; Estephan, Bachir

    2018-01-01

    The clinical examination of the trigeminal and facial nerves provides significant diagnostic value, especially in the localization of lesions in disorders affecting the central and/or peripheral nervous system. The electrodiagnostic evaluation of these nerves and their pathways adds further accuracy and reliability to the diagnostic investigation and the localization process, especially when different testing methods are combined based on the clinical presentation and the electrophysiological findings. The diagnostic uniqueness of the trigeminal and facial nerves is their connectivity and their coparticipation in reflexes commonly used in clinical practice, namely the blink and corneal reflexes. The other reflexes used in the diagnostic process and lesion localization are very nerve specific and add more diagnostic yield to the workup of certain disorders of the nervous system. This article provides a review of commonly used electrodiagnostic studies and techniques in the evaluation and lesion localization of cranial nerves V and VII.

  8. Development of a gas-cylinder-free plasma desorption/ionization system for on-site detection of chemical warfare agents.

    Science.gov (United States)

    Iwai, Takahiro; Kakegawa, Ken; Aida, Mari; Nagashima, Hisayuki; Nagoya, Tomoki; Kanamori-Kataoka, Mieko; Miyahara, Hidekazu; Seto, Yasuo; Okino, Akitoshi

    2015-06-02

    A gas-cylinder-free plasma desorption/ionization system was developed to realize a mobile on-site analytical device for detection of chemical warfare agents (CWAs). In this system, the plasma source was directly connected to the inlet of a mass spectrometer. The plasma can be generated with ambient air, which is drawn into the discharge region by negative pressure in the mass spectrometer. High-power density pulsed plasma of 100 kW could be generated by using a microhollow cathode and a laboratory-built high-intensity pulsed power supply (pulse width: 10-20 μs; repetition frequency: 50 Hz). CWAs were desorbed and protonated in the enclosed space adjacent to the plasma source. Protonated sample molecules were introduced to the mass spectrometer by airflow through the discharge region. To evaluate the analytical performance of this device, helium and air plasma were directly irradiated to CWAs in the gas-cylinder-free plasma desorption/ionization system and the protonated molecules were analyzed by using an ion-trap mass spectrometer. A blister agent (nitrogen mustard 3) and nerve gases [cyclohexylsarin (GF), tabun (GA), and O-ethyl S-2-N,N-diisopropylaminoethyl methylphosphonothiolate (VX)] in solution in n-hexane were applied to the Teflon rod and used as test samples, after solvent evaporation. As a result, protonated molecules of CWAs were successfully observed as the characteristic ion peaks at m/z 204, 181, 163, and 268, respectively. In air plasma, the limits of detection were estimated to be 22, 20, 4.8, and 1.0 pmol, respectively, which were lower than those obtained with helium plasma. To achieve quantitative analysis, calibration curves were made by using CWA stimulant dipinacolyl methylphosphonate as an internal standard; straight correlation lines (R(2) = 0.9998) of the peak intensity ratios (target per internal standard) were obtained. Remarkably, GA and GF gave protonated dimer ions, and the ratios of the protonated dimer ions to the protonated

  9. Miconazole enhances nerve regeneration and functional recovery after sciatic nerve crush injury.

    Science.gov (United States)

    Lin, Tao; Qiu, Shuai; Yan, Liwei; Zhu, Shuang; Zheng, Canbin; Zhu, Qingtang; Liu, Xiaolin

    2018-05-01

    Improving axonal outgrowth and remyelination is crucial for peripheral nerve regeneration. Miconazole appears to enhance remyelination in the central nervous system. In this study we assess the effect of miconazole on axonal regeneration using a sciatic nerve crush injury model in rats. Fifty Sprague-Dawley rats were divided into control and miconazole groups. Nerve regeneration and myelination were determined using histological and electrophysiological assessment. Evaluation of sensory and motor recovery was performed using the pinprick assay and sciatic functional index. The Cell Counting Kit-8 assay and Western blotting were used to assess the proliferation and neurotrophic expression of RSC 96 Schwann cells. Miconazole promoted axonal regrowth, increased myelinated nerve fibers, improved sensory recovery and walking behavior, enhanced stimulated amplitude and nerve conduction velocity, and elevated proliferation and neurotrophic expression of RSC 96 Schwann cells. Miconazole was beneficial for nerve regeneration and functional recovery after peripheral nerve injury. Muscle Nerve 57: 821-828, 2018. © 2017 Wiley Periodicals, Inc.

  10. Delayed peripheral nerve repair: methods, including surgical ′cross-bridging′ to promote nerve regeneration

    Directory of Open Access Journals (Sweden)

    Tessa Gordon

    2015-01-01

    Full Text Available Despite the capacity of Schwann cells to support peripheral nerve regeneration, functional recovery after nerve injuries is frequently poor, especially for proximal injuries that require regenerating axons to grow over long distances to reinnervate distal targets. Nerve transfers, where small fascicles from an adjacent intact nerve are coapted to the nerve stump of a nearby denervated muscle, allow for functional return but at the expense of reduced numbers of innervating nerves. A 1-hour period of 20 Hz electrical nerve stimulation via electrodes proximal to an injury site accelerates axon outgrowth to hasten target reinnervation in rats and humans, even after delayed surgery. A novel strategy of enticing donor axons from an otherwise intact nerve to grow through small nerve grafts (cross-bridges into a denervated nerve stump, promotes improved axon regeneration after delayed nerve repair. The efficacy of this technique has been demonstrated in a rat model and is now in clinical use in patients undergoing cross-face nerve grafting for facial paralysis. In conclusion, brief electrical stimulation, combined with the surgical technique of promoting the regeneration of some donor axons to ′protect′ chronically denervated Schwann cells, improves nerve regeneration and, in turn, functional outcomes in the management of peripheral nerve injuries.

  11. Neuroprotective Drug for Nerve Trauma Revealed Using Artificial Intelligence

    OpenAIRE

    Romeo-Guitart, David; Forés, Joaquim; Herrando-Grabulosa, Mireia; Valls, Raquel; Leiva-Rodríguez, Tatiana; Galea, Elena; González-Pérez, Francisco; Navarro, Xavier; Petegnief, Valerie; Bosch, Assumpció; Coma, Mireia; Mas, José Manuel; Casas, Caty

    2018-01-01

    Here we used a systems biology approach and artificial intelligence to identify a neuroprotective agent for the treatment of peripheral nerve root avulsion. Based on accumulated knowledge of the neurodegenerative and neuroprotective processes that occur in motoneurons after root avulsion, we built up protein networks and converted them into mathematical models. Unbiased proteomic data from our preclinical models were used for machine learning algorithms and for restrictions to be imposed on m...

  12. On the effect of N-GaN/P-GaN/N-GaN/P-GaN/N-GaN built-in junctions in the n-GaN layer for InGaN/GaN light-emitting diodes.

    Science.gov (United States)

    Kyaw, Zabu; Zhang, Zi-Hui; Liu, Wei; Tan, Swee Tiam; Ju, Zhen Gang; Zhang, Xue Liang; Ji, Yun; Hasanov, Namig; Zhu, Binbin; Lu, Shunpeng; Zhang, Yiping; Sun, Xiao Wei; Demir, Hilmi Volkan

    2014-01-13

    N-GaN/P-GaN/N-GaN/P-GaN/N-GaN (NPNPN-GaN) junctions embedded between the n-GaN region and multiple quantum wells (MQWs) are systematically studied both experimentally and theoretically to increase the performance of InGaN/GaN light emitting diodes (LEDs) in this work. In the proposed architecture, each thin P-GaN layer sandwiched in the NPNPN-GaN structure is completely depleted due to the built-in electric field in the NPNPN-GaN junctions, and the ionized acceptors in these P-GaN layers serve as the energy barriers for electrons from the n-GaN region, resulting in a reduced electron over flow and enhanced the current spreading horizontally in the n- GaN region. These lead to increased optical output power and external quantum efficiency (EQE) from the proposed device.

  13. Optic Nerve Disorders

    Science.gov (United States)

    The optic nerve is a bundle of more than 1 million nerve fibers that carry visual messages. You have one connecting ... retina) to your brain. Damage to an optic nerve can cause vision loss. The type of vision ...

  14. Progress of nerve bridges in the treatment of peripheral nerve disruptions

    OpenAIRE

    Ao,Qiang

    2016-01-01

    Qiang Ao Department of Tissue Engineering, School of Fundamental Science, China Medical University, Shenyang, Liaoning, Peoples’ Republic of China Abstract: Clinical repair of a nerve defect is one of the most challenging surgical problems. Autologous nerve grafting remains the gold standard treatment in addressing peripheral nerve injuries that cannot be bridged by direct epineural suturing. However, the autologous nerve graft is not readily available, and the process of harvesting...

  15. Optic Nerve Pit

    Science.gov (United States)

    ... Conditions Frequently Asked Questions Español Condiciones Chinese Conditions Optic Nerve Pit What is optic nerve pit? An optic nerve pit is a ... may be seen in both eyes. How is optic pit diagnosed? If the pit is not affecting ...

  16. The vestibulocochlear nerve (VIII).

    Science.gov (United States)

    Benoudiba, F; Toulgoat, F; Sarrazin, J-L

    2013-10-01

    The vestibulocochlear nerve (8th cranial nerve) is a sensory nerve. It is made up of two nerves, the cochlear, which transmits sound and the vestibular which controls balance. It is an intracranial nerve which runs from the sensory receptors in the internal ear to the brain stem nuclei and finally to the auditory areas: the post-central gyrus and superior temporal auditory cortex. The most common lesions responsible for damage to VIII are vestibular Schwannomas. This report reviews the anatomy and various investigations of the nerve. Copyright © 2013. Published by Elsevier Masson SAS.

  17. Functional nerve recovery after bridging a 15 mm gap in rat sciatic nerve with a biodegradable nerve guide

    NARCIS (Netherlands)

    Meek, MF; Klok, F; Robinson, PH; Nicolai, JPA; Gramsbergen, A; van der Werf, J.F.A.

    2003-01-01

    Recovery of nerve function was evaluated after bridging a 15 mm sciatic nerve gap in 51 rats with a biodegradable poly(DL-lactide-epsilon-caprolactone) nerve guide. Recovery of function was investigated by analysing the footprints, by analysing video recordings of gait, by electrically eliciting the

  18. The Use of Degradable Nerve Conduits for Human Nerve Repair: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    M. F. Meek

    2005-01-01

    Full Text Available The management of peripheral nerve injury continues to be a major clinical challenge. The most widely used technique for bridging defects in peripheral nerves is the use of autologous nerve grafts. This technique, however, has some disadvantages. Many alternative experimental techniques have thus been developed, such as degradable nerve conduits. Degradable nerve guides have been extensively studied in animal experimental studies. However, the repair of human nerves by degradable nerve conduits has been limited to only a few clinical studies. In this paper, an overview of the available international published literature on degradable nerve conduits for bridging human peripheral nerve defects is presented for literature available until 2004. Also, the philosophy on the use of nerve guides and nerve grafts is given.

  19. 67Ga imaging in Hodgkin's disease

    International Nuclear Information System (INIS)

    Huys, J.; Schelstraete, K.; Simons, M.

    1982-01-01

    In order to answer the question if 67 Ga imaging has a practical utility for the management of the patient with Hodgkin's disease, 108 scans performed on 60 patients were reviewed. When used during the initial staging of the disease or during restaging because of recurrences, 67 Ga imaging-at least in our experience-gave many false negative results in the cervical, axillary and inguinal areas, whereas the majority of true positive scans was found at the mediastinal level (including the lower mediastinum), and also in the lung parenchyma and the upper epigastric regions. Because of its lack of sensitivity, 67 Ga imaging cannot replace other staging procedures, but nevertheless is a valuable adjunctive test, as it can identify tumor localization that may have remained undetected by other methods. Fifty-four scans were performed to monitor treatment with radiation therapy or chemotherapeutic agents. Disappearance or decreases of 67 Ga uptake after treatment usually corresponded to a disappearance or regression of the tumor as ascertained by other methods. When the treatment was shown to be ineffective, 67 Ga uptake persisted or even became more prominent. When during follow-up, a new concentration of 67 Ga appeared at the original location or elsewhere, a relapse was extremely likely. However, one must be aware of false positive images. In our material, no correlation was found between the intensity of the 67 Ga uptake and the histological subtypes of Hodgkin's disease. Neither did we observe any relation to the blood sedimentation rate or serum iron levels

  20. [Glaucoma and optic nerve drusen: Limitations of optic nerve head OCT].

    Science.gov (United States)

    Poli, M; Colange, J; Goutagny, B; Sellem, E

    2017-09-01

    Optic nerve head drusen are congenital calcium deposits located in the prelaminar section of the optic nerve head. Their association with visual field defects has been classically described, but the diagnosis of glaucoma is not easy in these cases of altered optic nerve head anatomy. We describe the case of a 67-year-old man with optic nerve head drusen complicated by glaucoma, which was confirmed by visual field and OCT examination of the peripapillary retinal nerve fiber layer (RNFL), but the measurement of the minimum distance between the Bruch membrane opening and the internal limiting membrane (minimum rim width, BMO-MRW) by OCT was normal. OCT of the BMO-MRW is a new diagnostic tool for glaucoma. Superficial optic nerve head drusen, which are found between the internal limiting membrane and the Bruch's membrane opening, overestimate the value of this parameter. BMO-MRW measurement is not adapted to cases of optic nerve head drusen and can cause false-negative results for this parameter, and the diagnosis of glaucoma in this case should be based on other parameters such as the presence of a fascicular defect in the retinal nerve fibers, RNFL or macular ganglion cell complex thinning, as well as visual field data. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. A comprehensive evaluation of novel oximes in creation of butyrylcholinesterase-based nerve agent bioscavengers

    Energy Technology Data Exchange (ETDEWEB)

    Katalinić, Maja; Maček Hrvat, Nikolina [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia); Baumann, Krešimir; Morasi Piperčić, Sara; Makarić, Sandro; Tomić, Srđanka; Jović, Ozren; Hrenar, Tomica [Department of Chemistry, Faculty of Science, University of Zagreb, HR-10001 Zagreb (Croatia); Miličević, Ante [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia); Jelić, Dubravko [Fidelta Ltd., HR-10001 Zagreb (Croatia); Žunec, Suzana [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia); Primožič, Ines, E-mail: ines.primozic@chem.pmf.hr [Department of Chemistry, Faculty of Science, University of Zagreb, HR-10001 Zagreb (Croatia); Kovarik, Zrinka, E-mail: zkovarik@imi.hr [Institute for Medical Research and Occupational Health, POB 291, HR-10001 Zagreb (Croatia)

    2016-11-01

    A well-considered treatment of acute nerve agents poisoning involves the exogenous administration of butyrylcholinesterase (BChE, EC 3.1.1.8) as a stoichiometric bioscavenger efficient in preventing cholinergic crises caused by acetylcholinesterase (AChE, EC 3.1.1.7) inhibition. An additional improvement in medical countermeasures would be to use oximes that could reactivate BChE as well to upgrade bioscavenging from stoichiometric to oxime-assisted catalytic. Therefore, in this paper we investigated the potency of 39 imidazolium and benzimidazolium oximes (36 compounds synthesized for the first time) to be considered as the reactivators specifically designed for reactivation of phosphylated human BChE. Their efficiency in the reactivation of paraoxon-, VX-, and tabun-inhibited human BChE, as well as human AChE was tested and compared with the efficiencies of HI-6 and obidoxime, used in medical practice today. A comprehensive analysis was performed for the most promising oximes defining kinetic parameters of reactivation as well as interactions with uninhibited BChE. Furthermore, experimental data were compared with computational studies (docking, QSAR analysis) as a starting point in future oxime structure refinement. Considering the strict criteria set for in vivo applications, we determined the cytotoxicity of lead oximes on two cell lines. Among the tested oxime library, one imidazolium compound was selected for preliminary in vivo antidotal study in mice. The obtained protection in VX poisoning outlines its potential in development oxime-assisted OP-bioscavenging with BChE. - Highlights: • 36 new imidazolium and benzimidazolium oximes were designed and synthesized. • In vitro reactivation kinetics of phosphylated butyrylcholinesterase was studded. • The modes of actions were elucidated by QSAR and docking simulations. • Protection in VX poisoning was 6.3 × LD{sub 50} in in vivo antidotal study in mice. • Imidazolium oxime-assisted catalysis is

  2. A comprehensive evaluation of novel oximes in creation of butyrylcholinesterase-based nerve agent bioscavengers

    International Nuclear Information System (INIS)

    Katalinić, Maja; Maček Hrvat, Nikolina; Baumann, Krešimir; Morasi Piperčić, Sara; Makarić, Sandro; Tomić, Srđanka; Jović, Ozren; Hrenar, Tomica; Miličević, Ante; Jelić, Dubravko; Žunec, Suzana; Primožič, Ines; Kovarik, Zrinka

    2016-01-01

    A well-considered treatment of acute nerve agents poisoning involves the exogenous administration of butyrylcholinesterase (BChE, EC 3.1.1.8) as a stoichiometric bioscavenger efficient in preventing cholinergic crises caused by acetylcholinesterase (AChE, EC 3.1.1.7) inhibition. An additional improvement in medical countermeasures would be to use oximes that could reactivate BChE as well to upgrade bioscavenging from stoichiometric to oxime-assisted catalytic. Therefore, in this paper we investigated the potency of 39 imidazolium and benzimidazolium oximes (36 compounds synthesized for the first time) to be considered as the reactivators specifically designed for reactivation of phosphylated human BChE. Their efficiency in the reactivation of paraoxon-, VX-, and tabun-inhibited human BChE, as well as human AChE was tested and compared with the efficiencies of HI-6 and obidoxime, used in medical practice today. A comprehensive analysis was performed for the most promising oximes defining kinetic parameters of reactivation as well as interactions with uninhibited BChE. Furthermore, experimental data were compared with computational studies (docking, QSAR analysis) as a starting point in future oxime structure refinement. Considering the strict criteria set for in vivo applications, we determined the cytotoxicity of lead oximes on two cell lines. Among the tested oxime library, one imidazolium compound was selected for preliminary in vivo antidotal study in mice. The obtained protection in VX poisoning outlines its potential in development oxime-assisted OP-bioscavenging with BChE. - Highlights: • 36 new imidazolium and benzimidazolium oximes were designed and synthesized. • In vitro reactivation kinetics of phosphylated butyrylcholinesterase was studded. • The modes of actions were elucidated by QSAR and docking simulations. • Protection in VX poisoning was 6.3 × LD 50 in in vivo antidotal study in mice. • Imidazolium oxime-assisted catalysis is feasible

  3. Radioimmunodetection of tumor with Ga-67 labeled antibodies

    International Nuclear Information System (INIS)

    Furukawa, Takako; Endo, Keigo; Ohmomo, Yoshiro

    1986-01-01

    Antibodies against tumor associated antigen; anti-AFP polyclonal antibody, anti-thyroglobulin monoclonal antibody and anti-hCG monoclonal antibody, were labeled with Ga-67, using deferoxamine (DF) as a bifunctional chelating agent. The immunoreactivity and in vivo stability of the Ga-67 labeled antibodies were examined. The effect of DF conjugation to antibodies on the antigen-binding activity was evaluated by RIA and Scatchard analysis or tanned sheep red blood cell hemagglutination technique. When DF was conjugated to antibody at the molar ratio of 1 : 1, the antibody activity of the DF-conjugated antibodies was fully retained. Whereas, in heavily conjugated antibodies, the maximum antigen binding capacity was reduced. Biodistribution study in normal mice demonstrated the high in vivo stability of Ga-67 labeled antibodies. The labeling of DF-antibody conjugated with Ga-67 was performed easily and quickly, with a high labeling efficiency, requiring no further purification. Thus, this labeling method, providing in vivo stability of Ga-67 labeled antibody and full retention of immunoreactivity, would be useful for the radioimmunodetection of various cancers. (author)

  4. Transient facial nerve palsy after occipital nerve block: a case report.

    Science.gov (United States)

    Strauss, Lauren; Loder, Elizabeth; Rizzoli, Paul

    2014-01-01

    Occipital nerve blocks are commonly performed to treat a variety of headache syndromes and are generally believed to be safe and well tolerated. We report the case of an otherwise healthy 24-year-old woman with left side-locked occipital, parietal, and temporal pain who was diagnosed with probable occipital neuralgia. She developed complete left facial nerve palsy within minutes of blockade of the left greater and lesser occipital nerves with a solution of bupivicaine and triamcinolone. Magnetic resonance imaging of the brain with gadolinium contrast showed no abnormalities, and symptoms had completely resolved 4-5 hours later. Unintended spread of the anesthetic solution along tissue planes seems the most likely explanation for this adverse event. An aberrant course of the facial nerve or connections between the facial and occipital nerves also might have played a role, along with the patient's prone position and the use of a relatively large injection volume of a potent anesthetic. Clinicians should be aware that temporary facial nerve palsy is a possible complication of occipital nerve block. © 2014 American Headache Society.

  5. May the Inferior Petrosal Sinus Recanalization During Endovascular Treatment for Carotid-Cavernous Fistulas Increase the Risk of Sixth Nerve Palsy?

    Science.gov (United States)

    Robert, Thomas; Valsecchi, Daniele; Sylvestre, Philippe; Blanc, Raphaël; Ciccio, Gabriele; Smajda, Stanislas; Redjem, Hocine; Piotin, Michel

    2018-05-03

    Sixth nerve palsy is a common complication of endovascular treatment for carotid-cavernous fistulas (CCF). Two hypotheses are evoked: the spontaneous venous congestion into the cavernous sinus and the direct compression of the nerve by the embolic agent into the cavernous sinus. Nevertheless, the evidence is still uncertain. Knowing the vicinity of the sixth nerve with the inferior petrosal sinus (IPS) in the Dorello canal, we hypothesized that the recanalization of the IPS increased the risk of nerve damage. We analyzed a prospective database of patients treated for CCFs from March 2009 to April 2016. We excluded patients who did not need treatment, cases of high-flow CCF, and patients lost to follow-up, obtaining a homogeneous population of 82 patients with indirect CCFs. This population was divided in 2 groups: patients without new-onset/worsening of sixth nerve palsy and patients with this postprocedural complication. Our main endpoints were the potential differences between patients with or without recanalization of IPS and between those who underwent or not an embolization with Onyx-18. We did not find any statistically meaningful difference between the 2 groups concerning the necessity of IPS recanalization (P > 0.999, odds ratio 0.97, 95% confidence interval 0.32-2.96) or with the use of Onyx-18 as an embolic agent (P = 0.56; odds ratio 1.41, 95% confidence interval 0.41-2.45). The recanalization of a thrombosed IPS does not increase the risk of procedural sixth nerve damage. The initial injury seems to relate with development/worsening of a sixth nerve palsy. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. 142 Key words: Brachialis, radial nerve, musculocutaneous nerve.

    African Journals Online (AJOL)

    AWORI KIRSTEEN

    The innervation of brachialis muscle by the musculocutaneous nerve has been described as either type I or type II and the main trunk to this muscle is rarely absent. The contribution .... brachialis muscle by fiber analysis of supply nerves].

  7. Mitochondrial complex II, a novel target for anti-cancer agents

    Czech Academy of Sciences Publication Activity Database

    Klučková, Katarína; Bezawork-Geleta, A.; Rohlena, Jakub; Dong, L.; Neužil, Jiří

    2013-01-01

    Roč. 1827, č. 5 (2013), s. 552-564 ISSN 0005-2728 R&D Projects: GA ČR(CZ) GAP301/10/1937; GA ČR GAP301/12/1851 Institutional research plan: CEZ:AV0Z50520701 Keywords : Mitochondrion * Complex II * Anti-cancer agent Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.829, year: 2013

  8. Facial reanimation by muscle-nerve neurotization after facial nerve sacrifice. Case report.

    Science.gov (United States)

    Taupin, A; Labbé, D; Babin, E; Fromager, G

    2016-12-01

    Recovering a certain degree of mimicry after sacrifice of the facial nerve is a clinically recognized finding. The authors report a case of hemifacial reanimation suggesting a phenomenon of neurotization from muscle-to-nerve. A woman benefited from a parotidectomy with sacrifice of the left facial nerve indicated for recurrent tumor in the gland. The distal branches of the facial nerve, isolated at the time of resection, were buried in the masseter muscle underneath. The patient recovered a voluntary hémifacial motricity. The electromyographic analysis of the motor activity of the zygomaticus major before and after block of the masseter nerve showed a dependence between mimic muscles and the masseter muscle. Several hypotheses have been advanced to explain the spontaneous reanimation of facial paralysis. The clinical case makes it possible to argue in favor of muscle-to-nerve neurotization from masseter muscle to distal branches of the facial nerve. It illustrates the quality of motricity that can be obtained thanks to this procedure. The authors describe a simple implantation technique of distal branches of the facial nerve in the masseter muscle during a radical parotidectomy with facial nerve sacrifice and recovery of resting tone but also a quality voluntary mimicry. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. Preparation and biological studies of 68Ga-DOTA-alendronate

    Directory of Open Access Journals (Sweden)

    Ashraf Fakhari

    2016-07-01

    Full Text Available Objective(s: In line with previous research on the development of conjugated bisphosphonate ligands as new bone-avid agents, in this study, DOTA conjugated alendronate (DOTA-ALN was synthesized and evaluated after labeling with gallium-68 (68Ga.Methods: DOTA-ALN was synthesized and characterized, followed by 68Ga-DOTA-ALN preparation, using DOTA-ALN and 68GaCl3 (pH: 4-5 at 92-95°C for 10 min. Stability tests, hydroxyapatite assay, partition coefficient calculation,biodistribution studies, and imaging were performed on the developed agent in normal rats.Results: The complex was prepared with high radiochemical purity (>99% as depicted by radio thin-layer chromatography; specific activity: 310-320GBq/mmol after solid phase purification and was stabilized for up to 90 min with a logP value of -2.91. Maximum ligand binding (65% was observed in the presence of 50 mg of hydroxyapatite; a major portion of the activity was excreted through the kidneys. With the exception of excretory organs, gastrointestinal tract organs, including the liver, intestine, and colon, showed significant uptake; however, the bone uptake was low (

  10. The longitudinal epineural incision and complete nerve transection method for modeling sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Xing-long Cheng

    2015-01-01

    Full Text Available Injury severity, operative technique and nerve regeneration are important factors to consider when constructing a model of peripheral nerve injury. Here, we present a novel peripheral nerve injury model and compare it with the complete sciatic nerve transection method. In the experimental group, under a microscope, a 3-mm longitudinal incision was made in the epineurium of the sciatic nerve to reveal the nerve fibers, which were then transected. The small, longitudinal incision in the epineurium was then sutured closed, requiring no stump anastomosis. In the control group, the sciatic nerve was completely transected, and the epineurium was repaired by anastomosis. At 2 and 4 weeks after surgery, Wallerian degeneration was observed in both groups. In the experimental group, at 8 and 12 weeks after surgery, distinct medullary nerve fibers and axons were observed in the injured sciatic nerve. Regular, dense myelin sheaths were visible, as well as some scarring. By 12 weeks, the myelin sheaths were normal and intact, and a tight lamellar structure was observed. Functionally, limb movement and nerve conduction recovered in the injured region between 4 and 12 weeks. The present results demonstrate that longitudinal epineural incision with nerve transection can stably replicate a model of Sunderland grade IV peripheral nerve injury. Compared with the complete sciatic nerve transection model, our method reduced the difficulties of micromanipulation and surgery time, and resulted in good stump restoration, nerve regeneration, and functional recovery.

  11. An anatomical study of porcine peripheral nerve and its potential use in nerve tissue engineering

    Science.gov (United States)

    Zilic, Leyla; Garner, Philippa E; Yu, Tong; Roman, Sabiniano; Haycock, John W; Wilshaw, Stacy-Paul

    2015-01-01

    Current nerve tissue engineering applications are adopting xenogeneic nerve tissue as potential nerve grafts to help aid nerve regeneration. However, there is little literature that describes the exact location, anatomy and physiology of these nerves to highlight their potential as a donor graft. The aim of this study was to identify and characterise the structural and extracellular matrix (ECM) components of porcine peripheral nerves in the hind leg. Methods included the dissection of porcine nerves, localisation, characterisation and quantification of the ECM components and identification of nerve cells. Results showed a noticeable variance between porcine and rat nerve (a commonly studied species) in terms of fascicle number. The study also revealed that when porcine peripheral nerves branch, a decrease in fascicle number and size was evident. Porcine ECM and nerve fascicles were found to be predominately comprised of collagen together with glycosaminoglycans, laminin and fibronectin. Immunolabelling for nerve growth factor receptor p75 also revealed the localisation of Schwann cells around and inside the fascicles. In conclusion, it is shown that porcine peripheral nerves possess a microstructure similar to that found in rat, and is not dissimilar to human. This finding could extend to the suggestion that due to the similarities in anatomy to human nerve, porcine nerves may have utility as a nerve graft providing guidance and support to regenerating axons. PMID:26200940

  12. Microvascular Cranial Nerve Palsy

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Microvascular Cranial Nerve Palsy Sections What Is Microvascular Cranial Nerve Palsy? ... Microvascular Cranial Nerve Palsy Treatment What Is Microvascular Cranial Nerve Palsy? Leer en Español: ¿Qué es una parálisis ...

  13. Engineering a multimodal nerve conduit for repair of injured peripheral nerve

    Science.gov (United States)

    Quigley, A. F.; Bulluss, K. J.; Kyratzis, I. L. B.; Gilmore, K.; Mysore, T.; Schirmer, K. S. U.; Kennedy, E. L.; O'Shea, M.; Truong, Y. B.; Edwards, S. L.; Peeters, G.; Herwig, P.; Razal, J. M.; Campbell, T. E.; Lowes, K. N.; Higgins, M. J.; Moulton, S. E.; Murphy, M. A.; Cook, M. J.; Clark, G. M.; Wallace, G. G.; Kapsa, R. M. I.

    2013-02-01

    Injury to nerve tissue in the peripheral nervous system (PNS) results in long-term impairment of limb function, dysaesthesia and pain, often with associated psychological effects. Whilst minor injuries can be left to regenerate without intervention and short gaps up to 2 cm can be sutured, larger or more severe injuries commonly require autogenous nerve grafts harvested from elsewhere in the body (usually sensory nerves). Functional recovery is often suboptimal and associated with loss of sensation from the tissue innervated by the harvested nerve. The challenges that persist with nerve repair have resulted in development of nerve guides or conduits from non-neural biological tissues and various polymers to improve the prognosis for the repair of damaged nerves in the PNS. This study describes the design and fabrication of a multimodal controlled pore size nerve regeneration conduit using polylactic acid (PLA) and (PLA):poly(lactic-co-glycolic) acid (PLGA) fibers within a neurotrophin-enriched alginate hydrogel. The nerve repair conduit design consists of two types of PLGA fibers selected specifically for promotion of axonal outgrowth and Schwann cell growth (75:25 for axons; 85:15 for Schwann cells). These aligned fibers are contained within the lumen of a knitted PLA sheath coated with electrospun PLA nanofibers to control pore size. The PLGA guidance fibers within the nerve repair conduit lumen are supported within an alginate hydrogel impregnated with neurotrophic factors (NT-3 or BDNF with LIF, SMDF and MGF-1) to provide neuroprotection, stimulation of axonal growth and Schwann cell migration. The conduit was used to promote repair of transected sciatic nerve in rats over a period of 4 weeks. Over this period, it was observed that over-grooming and self-mutilation (autotomy) of the limb implanted with the conduit was significantly reduced in rats implanted with the full-configuration conduit compared to rats implanted with conduits containing only an alginate

  14. Thoracoscopic patch insulation to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy.

    Science.gov (United States)

    Mediratta, Neeraj; Barker, Diane; McKevith, James; Davies, Peter; Belchambers, Sandra; Rao, Archana

    2012-07-01

    Cardiac resynchronization therapy is an established therapy for heart failure, improving quality of life and prognosis. Despite advances in technique, available leads and delivery systems, trans-venous left ventricular (LV) lead positioning remains dependent on the patient's underlying venous anatomy. The left phrenic nerve courses over the surface of the pericardium laterally and may be stimulated by the LV pacing lead, causing uncomfortable diaphragmatic twitch. This paper describes a video-assisted thoracoscopic (VATS) procedure to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy. Most current ways of avoiding phrenic stimulation involve either electronic reprogramming to distance the phrenic nerve from the stimulation circuit or repositioning the lead. We describe a case where the phrenic nerve was surgically insulated from the stimulating current by insinuating a patch of bovine pericardium between the epicardium and native pericardium of the heart thus completely resolving previously intolerable and incessant diaphragmatic twitch. The procedure was performed under general anaesthesia with single-lung ventilation and minimal use of neuromuscular blocking agents. Surgical patch insulation of the phrenic nerve was performed using minimally invasive VATS surgery, as a short-stay procedure, with no complications. No diaphragmatic twitch occurred post-surgery and the patient continued to gain symptomatic benefit from cardiac synchronization therapy (New York Heart Association Class III to II), enabling return to work. In cases where the trans-venous position of a LV lead is limited by troublesome phrenic nerve stimulation, thoracoscopic surgical patch insulation of the phrenic nerve could be considered to allow beneficial cardiac resynchronization therapy.

  15. Facial nerve conduction after sclerotherapy in children with facial lymphatic malformations: report of two cases.

    Science.gov (United States)

    Lin, Pei-Jung; Guo, Yuh-Cherng; Lin, Jan-You; Chang, Yu-Tang

    2007-04-01

    Surgical excision is thought to be the standard treatment of choice for lymphatic malformations. However, when the lesions are limited to the face only, surgical scar and facial nerve injury may impair cosmetics and facial expression. Sclerotherapy, an injection of a sclerosing agent directly through the skin into a lesion, is an alternative method. By evaluating facial nerve conduction, we observed the long-term effect of facial lymphatic malformations after intralesional injection of OK-432 and correlated the findings with anatomic outcomes. One 12-year-old boy with a lesion over the right-side preauricular area adjacent to the main trunk of facial nerve and the other 5-year-old boy with a lesion in the left-sided cheek involving the buccinator muscle were enrolled. The follow-up data of more than one year, including clinical appearance, computed tomography (CT) scan and facial nerve evaluation were collected. The facial nerve conduction study was normal in both cases. Blink reflex in both children revealed normal results as well. Complete resolution was noted on outward appearance and CT scan. The neurophysiologic data were compatible with good anatomic and functional outcomes. Our report suggests that the inflammatory reaction of OK-432 did not interfere with adjacent facial nerve conduction.

  16. Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.

    Science.gov (United States)

    Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin

    2018-07-01

    Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.

  17. Enhanced peripheral nerve regeneration through asymmetrically porous nerve guide conduit with nerve growth factor gradient.

    Science.gov (United States)

    Oh, Se Heang; Kang, Jun Goo; Kim, Tae Ho; Namgung, Uk; Song, Kyu Sang; Jeon, Byeong Hwa; Lee, Jin Ho

    2018-01-01

    In this study, we fabricated a nerve guide conduit (NGC) with nerve growth factor (NGF) gradient along the longitudinal direction by rolling a porous polycaprolactone membrane with NGF concentration gradient. The NGF immobilized on the membrane was continuously released for up to 35 days, and the released amount of the NGF from the membrane gradually increased from the proximal to distal NGF ends, which may allow a neurotrophic factor gradient in the tubular NGC for a sufficient period. From the in vitro cell culture experiment, it was observed that the PC12 cells sense the NGF concentration gradient on the membrane for the cell proliferation and differentiation. From the in vivo animal experiment using a long gap (20 mm) sciatic nerve defect model of rats, the NGC with NGF concentration gradient allowed more rapid nerve regeneration through the NGC than the NGC itself and NGC immobilized with uniformly distributed NGF. The NGC with NGF concentration gradient seems to be a promising strategy for the peripheral nerve regeneration. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 52-64, 2018. © 2017 Wiley Periodicals, Inc.

  18. Primary nerve-sheath tumours of the trigeminal nerve: clinical and MRI findings

    International Nuclear Information System (INIS)

    Majoie, C.B.L.M.; Hulsmans, F.J.H.; Sie, L.H.; Castelijns, J.A.; Valk, J.; Walter, A.; Albrecht, K.W.

    1999-01-01

    We reviewed the clinical and MRI findings in primary nerve-sheath tumours of the trigeminal nerve. We retrospectively reviewed the medical records, imaging and histological specimens of 10 patients with 11 primary tumours of the trigeminal nerve. We assessed whether tumour site, size, morphology or signal characteristics were related to symptoms and signs or histological findings. Histological proof was available for 8 of 11 tumours: six schwannomas and two plexiform neurofibromas. The other three tumours were thought to be schwannomas, because they were present in patients with neurofibromatosis type 2 and followed the course of the trigeminal nerve. Uncommon MRI appearances were observed in three schwannomas and included a large intratumoral haemorrhage, a mainly low-signal appearance on T2-weighted images and a rim-enhancing, multicystic appearance. Only four of nine schwannomas caused trigeminal nerve symptoms, including two with large cystic components, one haemorrhagic and one solid tumor. Of the five schwannomas which did not cause any trigeminal nerve symptoms, two were large. Only one of the plexiform neurofibromas caused trigeminal nerve symptoms. Additional neurological symptoms and signs, not related to the trigeminal nerve, could be attributed to the location of the tumour in three patients. (orig.)

  19. Treatment of peroneal nerve injuries with simultaneous tendon transfer and nerve exploration.

    Science.gov (United States)

    Ho, Bryant; Khan, Zubair; Switaj, Paul J; Ochenjele, George; Fuchs, Daniel; Dahl, William; Cederna, Paul; Kung, Theodore A; Kadakia, Anish R

    2014-08-06

    Common peroneal nerve palsy leading to foot drop is difficult to manage and has historically been treated with extended bracing with expectant waiting for return of nerve function. Peroneal nerve exploration has traditionally been avoided except in cases of known traumatic or iatrogenic injury, with tendon transfers being performed in a delayed fashion after exhausting conservative treatment. We present a new strategy for management of foot drop with nerve exploration and concomitant tendon transfer. We retrospectively reviewed a series of 12 patients with peroneal nerve palsies that were treated with tendon transfer from 2005 to 2011. Of these patients, seven were treated with simultaneous peroneal nerve exploration and repair at the time of tendon transfer. Patients with both nerve repair and tendon transfer had superior functional results with active dorsiflexion in all patients, compared to dorsiflexion in 40% of patients treated with tendon transfers alone. Additionally, 57% of patients treated with nerve repair and tendon transfer were able to achieve enough function to return to running, compared to 20% in patients with tendon transfer alone. No patient had full return of native motor function resulting in excessive dorsiflexion strength. The results of our limited case series for this rare condition indicate that simultaneous nerve repair and tendon transfer showed no detrimental results and may provide improved function over tendon transfer alone.

  20. A STUDY OF TUMOURS OF THE CRANIAL NERVE AND PARASPINAL NERVE

    Directory of Open Access Journals (Sweden)

    Sudesh Shetty

    2016-03-01

    Full Text Available INTRODUCTION One of the frequent sites of tumour formation is the cranial nerves and paraspinal nerves. The cranial nerves perform a plethora of functions and so the signs and symptoms caused may be different. They are mainly classified into four different types. The aim of the study is: 1. To study the tumours arising from the cranial nerves in an epidemiological point of view. 2. To study the tumours histopathologically. 3. To classify the tumours according to WHO classification. Thirty-eight brain tumor cases were studied in the Department of Medicine, A. J. Shetty Institute of Medical Sciences, Mangalore. Cranial nerve tumours accounts for 4(10% among the intracranial tumours. Schwannomas makes up 3(7.39% among the Intracranial tumours. and constituted 3(75% among cranial nerve tumours. All the 3 schwannomas were located in CP angle. The geographic distribution of cases was found to be 28 cases from Mangalore and 10 cases from Kerala.

  1. Electrophysiology of Cranial Nerve Testing: Cranial Nerves IX and X.

    Science.gov (United States)

    Martinez, Alberto R M; Martins, Melina P; Moreira, Ana Lucila; Martins, Carlos R; Kimaid, Paulo A T; França, Marcondes C

    2018-01-01

    The cranial nerves IX and X emerge from medulla oblongata and have motor, sensory, and parasympathetic functions. Some of these are amenable to neurophysiological assessment. It is often hard to separate the individual contribution of each nerve; in fact, some of the techniques are indeed a composite functional measure of both nerves. The main methods are the evaluation of the swallowing function (combined IX and X), laryngeal electromyogram (predominant motor vagal function), and heart rate variability (predominant parasympathetic vagal function). This review describes, therefore, the techniques that best evaluate the major symptoms presented in IX and X cranial nerve disturbance: dysphagia, dysphonia, and autonomic parasympathetic dysfunction.

  2. Phrenic nerve transfer to the musculocutaneous nerve for the repair of brachial plexus injury: electrophysiological characteristics

    Directory of Open Access Journals (Sweden)

    Ying Liu

    2015-01-01

    Full Text Available Phrenic nerve transfer is a major dynamic treatment used to repair brachial plexus root avulsion. We analyzed 72 relevant articles on phrenic nerve transfer to repair injured brachial plexus that were indexed by Science Citation Index. The keywords searched were brachial plexus injury, phrenic nerve, repair, surgery, protection, nerve transfer, and nerve graft. In addition, we performed neurophysiological analysis of the preoperative condition and prognosis of 10 patients undergoing ipsilateral phrenic nerve transfer to the musculocutaneous nerve in our hospital from 2008 to 201 3 and observed the electromyograms of the biceps brachii and motor conduction function of the musculocutaneous nerve. Clinically, approximately 28% of patients had brachial plexus injury combined with phrenic nerve injury, and injured phrenic nerve cannot be used as a nerve graft. After phrenic nerve transfer to the musculocutaneous nerve, the regenerated potentials first appeared at 3 months. Recovery of motor unit action potential occurred 6 months later and became more apparent at 12 months. The percent of patients recovering ′excellent′ and ′good′ muscle strength in the biceps brachii was 80% after 18 months. At 12 months after surgery, motor nerve conduction potential appeared in the musculocutaneous nerve in seven cases. These data suggest that preoperative evaluation of phrenic nerve function may help identify the most appropriate nerve graft in patients with an injured brachial plexus. The functional recovery of a transplanted nerve can be dynamically observed after the surgery.

  3. Phrenic nerve transfer to the musculocutaneous nerve for the repair of brachial plexus injury: electrophysiological characteristics.

    Science.gov (United States)

    Liu, Ying; Xu, Xun-Cheng; Zou, Yi; Li, Su-Rong; Zhang, Bin; Wang, Yue

    2015-02-01

    Phrenic nerve transfer is a major dynamic treatment used to repair brachial plexus root avulsion. We analyzed 72 relevant articles on phrenic nerve transfer to repair injured brachial plexus that were indexed by Science Citation Index. The keywords searched were brachial plexus injury, phrenic nerve, repair, surgery, protection, nerve transfer, and nerve graft. In addition, we performed neurophysiological analysis of the preoperative condition and prognosis of 10 patients undergoing ipsilateral phrenic nerve transfer to the musculocutaneous nerve in our hospital from 2008 to 201 3 and observed the electromyograms of the biceps brachii and motor conduction function of the musculocutaneous nerve. Clinically, approximately 28% of patients had brachial plexus injury combined with phrenic nerve injury, and injured phrenic nerve cannot be used as a nerve graft. After phrenic nerve transfer to the musculocutaneous nerve, the regenerated potentials first appeared at 3 months. Recovery of motor unit action potential occurred 6 months later and became more apparent at 12 months. The percent of patients recovering 'excellent' and 'good' muscle strength in the biceps brachii was 80% after 18 months. At 12 months after surgery, motor nerve conduction potential appeared in the musculocutaneous nerve in seven cases. These data suggest that preoperative evaluation of phrenic nerve function may help identify the most appropriate nerve graft in patients with an injured brachial plexus. The functional recovery of a transplanted nerve can be dynamically observed after the surgery.

  4. Structured Lyapunov functions for synchronization of identical affine-in-control agents-Unified approach

    Czech Academy of Sciences Publication Activity Database

    Hengster-Movric, K.; Šebek, M.; Čelikovský, Sergej

    2016-01-01

    Roč. 353, č. 14 (2016), s. 3457-3486 ISSN 0016-0032 R&D Projects: GA ČR GA13-20433S Grant - others:GA ČR(CZ) GJ16-25493Y Institutional support: RVO:67985556 Keywords : Multi-agent nonlinear systems * structured Lyapunov functions Subject RIV: BC - Control Systems Theory Impact factor: 3.139, year: 2016 http://library.utia.cas.cz/separaty/2016/TR/celikovsky-0462691.pdf

  5. Caffeine-hydrazones as anticancer agents with pronounced selectivity toward T-lymphoblastic leukaemia cells

    Czech Academy of Sciences Publication Activity Database

    Kaplánek, R.; Jakubek, M.; Rak, J.; Kejik, Z.; Havlík, M.; Dolenský, B.; Frydrych, I.; Hajduch, M.; Kolář, M.; Bogdanová, K.; Králová, Jarmila; Dzubak, P.; Král, V.

    2015-01-01

    Roč. 60, Jun (2015), s. 19-29 ISSN 0045-2068 Grant - others:GA MŠk(CZ) EE2.3.30.0060; GA MŠk CZ.1.07/2.3.00/30.0041; GA MŠk(CZ) LO1304 Program:EE; LD Institutional support: RVO:68378050 Keywords : Anticancer agents * Cancer treatment * Caffeine -hydrazones * Leukaemia * Selectivity Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.252, year: 2015

  6. Ga-66 labeled somatostatin analogue DOTA-DPhe1-Tyr3-octreotide as a potential agent for positron emission tomography imaging and receptor mediated internal radiotherapy of somatostatin receptor positive tumors

    International Nuclear Information System (INIS)

    Ugur, Oemer; Kothari, Paresh J.; Finn, Ronald D.; Zanzonico, Pat; Ruan, Shutian; Guenther, Ilonka; Maecke, Helmut R.; Larson, Steven M.

    2002-01-01

    Radionuclide labeled somatostatin analogues selectively target somatostatin receptor (SSTR)-expressing tumors as a basis for diagnosis and treatment of these tumors. Recently, a DOTA-functionalized somatostatin analogue, DOTATOC (DOTA-DPhe 1 -Tyr 3 -octreotide) has been developed. This compound has been shown to be superior to the other somatostatin analogues as indicated by its uniquely high tumor-to-non-target tissue ratio. DOTATOC can be labeled with a variety of radiometals including gallium radioisotopes. Gallium-66 is a positron emitting radionuclide (T 1/2 =9.5 hr; β + =56%), that can be produced in carrier free form by a low-beam energy cyclotron. In this study we investigated SSTR targeting characteristics of 66 Ga-DOTATOC in AR42J rat pancreas tumor implanted nude mice as a potential agent for diagnosis and receptor-mediated internal radiotherapy of SSTR-expressing tumors. We compared our results with 67 Ga- and 68 Ga- labeled DOTATOC. The radiolabeling procedure gave labeling yield ranged from 85-95% and radiochemical and chemical purity was >95%. In-vitro competitive binding curves and in-vivo competitive displacement studies with an excess of unlabeled peptide indicates that there is specific binding of the radioligand to SSTR. Animal biodistribution data and serial microPET TM images demonstrated rapid tumor uptake and rapid clearance from the blood and all tissues except kidney. Maximum % ID/g values for tumor were 10.0±0.7, 13.2±2.1 and 9.8±1.5 for 66 Ga-, 67 Ga-, and 68 Ga-DOTATOC, respectively. Calculated tumor, kidney and bone marrow doses for 66 Ga-DOTATOC based on biodistribution data were 178, 109 and 1.2 cGy/MBq, respectively. We conclude that 66 Ga labeled DOTATOC can be used for PET diagnosis and quantitative imaging-based dosimetry of SSTR positive tumors. 66 Ga-DOTATOC may also be used in higher doses for ablation of these tumors. However, kidney is the critical organ for toxicity (tumor/kidney ratio 1.64), and high kidney uptake must

  7. An update-tissue engineered nerve grafts for the repair of peripheral nerve injuries.

    Science.gov (United States)

    Patel, Nitesh P; Lyon, Kristopher A; Huang, Jason H

    2018-05-01

    Peripheral nerve injuries (PNI) are caused by a range of etiologies and result in a broad spectrum of disability. While nerve autografts are the current gold standard for the reconstruction of extensive nerve damage, the limited supply of autologous nerve and complications associated with harvesting nerve from a second surgical site has driven groups from multiple disciplines, including biomedical engineering, neurosurgery, plastic surgery, and orthopedic surgery, to develop a suitable or superior alternative to autografting. Over the last couple of decades, various types of scaffolds, such as acellular nerve grafts (ANGs), nerve guidance conduits, and non-nervous tissues, have been filled with Schwann cells, stem cells, and/or neurotrophic factors to develop tissue engineered nerve grafts (TENGs). Although these have shown promising effects on peripheral nerve regeneration in experimental models, the autograft has remained the gold standard for large nerve gaps. This review provides a discussion of recent advances in the development of TENGs and their efficacy in experimental models. Specifically, TENGs have been enhanced via incorporation of genetically engineered cells, methods to improve stem cell survival and differentiation, optimized delivery of neurotrophic factors via drug delivery systems (DDS), co-administration of platelet-rich plasma (PRP), and pretreatment with chondroitinase ABC (Ch-ABC). Other notable advancements include conduits that have been bioengineered to mimic native nerve structure via cell-derived extracellular matrix (ECM) deposition, and the development of transplantable living nervous tissue constructs from rat and human dorsal root ganglia (DRG) neurons. Grafts composed of non-nervous tissues, such as vein, artery, and muscle, will be briefly discussed.

  8. Silk fibroin enhances peripheral nerve regeneration by improving vascularization within nerve conduits.

    Science.gov (United States)

    Wang, Chunyang; Jia, Yachao; Yang, Weichao; Zhang, Cheng; Zhang, Kuihua; Chai, Yimin

    2018-07-01

    Silk fibroin (SF)-based nerve conduits have been widely used to bridge peripheral nerve defects. Our previous study showed that nerve regeneration in a SF-blended poly (l-lactide-co-ɛ-caprolactone) [P(LLA-CL)] nerve conduit is better than that in a P(LLA-CL) conduit. However, the involved mechanisms remain unclarified. Because angiogenesis within a nerve conduit plays an important role in nerve regeneration, vascularization of SF/P(LLA-CL) and P(LLA-CL) conduits was compared both in vitro and in vivo. In the present study, we observed that SF/P(LLA-CL) nanofibers significantly promoted fibroblast proliferation, and vascular endothelial growth factor secreted by fibroblasts seeded in SF/P(LLA-CL) nanofibers was more than seven-fold higher than that in P(LLA-CL) nanofibers. Conditioned medium of fibroblasts in the SF/P(LLA-CL) group stimulated more human umbilical vein endothelial cells (HUVEC) to form capillary-like networks and promoted faster HUVEC migration. The two kinds of nerve conduits were used to bridge 10-mm-length nerve defects in rats. At 3 weeks of reparation, the blood vessel area in the SF/P(LLA-CL) group was significantly larger than that in the P(LLA-CL) group. More regenerated axons and Schwann cells were also observed in the SF/P(LLA-CL) group, which was consistent with the results of blood vessels. Collectively, our data revealed that the SF/P(LLA-CL) nerve conduit enhances peripheral nerve regeneration by improving angiogenesis within the conduit. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2070-2077, 2018. © 2018 Wiley Periodicals, Inc.

  9. Pre-differentiation of mesenchymal stromal cells in combination with a microstructured nerve guide supports peripheral nerve regeneration in the rat sciatic nerve model.

    Science.gov (United States)

    Boecker, Arne Hendrik; van Neerven, Sabien Geraldine Antonia; Scheffel, Juliane; Tank, Julian; Altinova, Haktan; Seidensticker, Katrin; Deumens, Ronald; Tolba, Rene; Weis, Joachim; Brook, Gary Anthony; Pallua, Norbert; Bozkurt, Ahmet

    2016-02-01

    Many bioartificial nerve guides have been investigated pre-clinically for their nerve regeneration-supporting function, often in comparison to autologous nerve transplantation, which is still regarded as the current clinical gold standard. Enrichment of these scaffolds with cells intended to support axonal regeneration has been explored as a strategy to boost axonal regeneration across these nerve guides Ansselin et al. (1998). In the present study, 20 mm rat sciatic nerve defects were implanted with a cell-seeded microstructured collagen nerve guide (Perimaix) or an autologous nerve graft. Under the influence of seeded, pre-differentiated mesenchymal stromal cells, axons regenerated well into the Perimaix nerve guide. Myelination-related parameters, like myelin sheath thickness, benefitted from an additional seeding with pre-differentiated mesenchymal stromal cells. Furthermore, both the number of retrogradely labelled sensory neurons and the axon density within the implant were elevated in the cell-seeded scaffold group with pre-differentiated mesenchymal stromal cells. However, a pre-differentiation had no influence on functional recovery. An additional cell seeding of the Perimaix nerve guide with mesenchymal stromal cells led to an extent of functional recovery, independent of the differentiation status, similar to autologous nerve transplantation. These findings encourage further investigations on pre-differentiated mesenchymal stromal cells as a cellular support for peripheral nerve regeneration. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  10. Should we routinely expose recurrent laryngeal nerve(s) during thyroid surgery

    International Nuclear Information System (INIS)

    Ahmed, M.; Aurangzeb, A.; Rashid, A.Z.; Qureshi, M.A.; Iqbal, N.; Boota, M.; Ashfaq, M.

    2013-01-01

    Objective: To compare the frequency of recurrent laryngeal nerve(s) (RLNs) palsy after various thyroid procedures with and without identification of recurrent laryngeal nerve during the operation. Study Design: Randomized controlled trial. Place and Duration of Study: Department of Surgery, Military Hospital, Rawalpindi, from August 2008 to April 2010. Methodology: Patients undergoing indirect laryngoscopy with normal vocal cords and those with carcinoma and re-do surgery having normal vocal cord were included in the study. Patients with hoarseness of voice, abnormal vocal cord movements and with solitary nodule in the isthmus were excluded. These patients were randomly divided into 2 groups of 50 each using random number tables. RLN was identified by exposing the inferior thyroid artery and traced along its entire course in group-A. Whereas, in group-B, nerves were not identified during the operations. Immediate postoperative direct laryngoscopy was performed by a surgeon with the help of an anaesthesiologist for the assessment of vocal cords. Patients with persistent hoarseness of voice were followed-up with indirect laryngoscopy at 3 and 6 months. Results: Temporary unilateral recurrent laryngeal nerve palsies occurred in 2 (4%) patients in group-A where the voice and cord movements returned to normal in 6 months. In group-B, it occurred in 8 (16%) patients, 2 bilateral (4%) injuries requiring tracheostomy and 6 unilateral injuries (12%). Among the 2 bilateral recurrent laryngeal nerve injuries, the tracheostomy was removed in one case after 6 months with persistent hoarseness of voice but no respiratory difficulty during routine activities. Tracheostomy was permanent in the other case. Among the 6 cases of unilateral nerve injuries, the voice improved considerably in 4 cases within 6 months but in 2 cases hoarseness persisted even after 6 months. Frequency of recurrent laryngeal nerve palsies was significantly lower in group-A as compared to group-B (p = 0

  11. Local anesthetic-induced myotoxicity as a cause of severe trismus after inferior alveolar nerve block.

    Science.gov (United States)

    Smolka, Wenko; Knoesel, Thomas; Mueller-Lisse, Ullrich

    2018-01-01

    A case of a 60-year-old man with severe trismus after inferior alveolar nerve block is presented. MRI scans as well as histologic examination revealed muscle fibrosis and degeneration of the medial part of the left temporal muscle due to myotoxicity of a local anesthetic agent.

  12. Intraoperative cranial nerve monitoring.

    Science.gov (United States)

    Harper, C Michel

    2004-03-01

    The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.

  13. Short-term observations of the regenerative potential of injured proximal sensory nerves crossed with distal motor nerves

    Directory of Open Access Journals (Sweden)

    Xiu-xiu Zhang

    2017-01-01

    Full Text Available Motor nerves and sensory nerves conduct signals in different directions and function in different ways. In the surgical treatment of peripheral nerve injuries, the best prognosis is obtained by keeping the motor and sensory nerves separated and repairing the nerves using the suture method. However, the clinical consequences of connections between sensory and motor nerves currently remain unknown. In this study, we analyzed the anatomical structure of the rat femoral nerve, and observed the motor and sensory branches of the femoral nerve in the quadriceps femoris. After ligation of the nerves, the proximal end of the sensory nerve was connected with the distal end of the motor nerve, followed by observation of the changes in the newly-formed regenerated nerve fibers. Acetylcholinesterase staining was used to distinguish between the myelinated and unmyelinated motor and sensory nerves. Denervated muscle and newly formed nerves were compared in terms of morphology, electrophysiology and histochemistry. At 8 weeks after connection, no motor nerve fibers were observed on either side of the nerve conduit and the number of nerve fibers increased at the proximal end. The proportion of newly-formed motor and sensory fibers was different on both sides of the conduit. The area occupied by autonomic nerves in the proximal regenerative nerve was limited, but no distinct myelin sheath was visible in the distal nerve. These results confirm that sensory and motor nerves cannot be effectively connected. Moreover, the change of target organ at the distal end affects the type of nerves at the proximal end.

  14. Adult Stem Cell Based Enhancement of Nerve Conduit for Peripheral Nerve Repair

    Science.gov (United States)

    2016-10-01

    accompanied by injuries to peripheral nerves; if not repaired, the trauma can lead to significant dysfunction and disability . While nerves have the ability to...recovery, minimized disability , and increased quality of life for our wounded warriors. 2. KEYWORDS: Stem Cell, Nerve Conduit, Peripheral Nerve...would be a paradigm shift away from ordering X-rays at 10-12 weeks and only ordering a CT scan. It has the potential to change the standard of care

  15. Microsurgical reconstruction of large nerve defects using autologous nerve grafts.

    Science.gov (United States)

    Daoutis, N K; Gerostathopoulos, N E; Efstathopoulos, D G; Misitizis, D P; Bouchlis, G N; Anagnostou, S K

    1994-01-01

    Between 1986 and 1993, 643 patients with peripheral nerve trauma were treated in our clinic. Primary neurorraphy was performed in 431 of these patients and nerve grafting in 212 patients. We present the functional results after nerve grafting in 93 patients with large nerve defects who were followed for more than 2 years. Evaluation of function was based on the Medical Research Council (MRC) classification for motor and sensory recovery. Factors affecting functional outcome, such as age of the patient, denervation time, length of the defect, and level of the injury were noted. Good results according to the MRC classification were obtained in the majority of cases, although function remained less than that of the uninjured side.

  16. Clusters of magnetic nanoparticles as contrast agents for MRI: effect of aggregation on transverse relaxivity

    Czech Academy of Sciences Publication Activity Database

    Dědourková, T.; Kaman, Ondřej; Veverka, Pavel; Koktan, Jakub; Veverka, Miroslav; Kuličková, Jarmila; Jirák, Zdeněk; Herynek, V.

    2015-01-01

    Roč. 51, č. 11 (2015), s. 5300804 ISSN 0018-9464 R&D Projects: GA ČR GA15-10088S; GA MPO FR-TI3/521 Institutional support: RVO:68378271 Keywords : contrast agents * magnetic resonance imaging * magnetic nanoparticles * manganites * transverse relaxivity Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.277, year: 2015

  17. Gradual nerve elongation affects nerve cell bodies and neuro-muscular junctions.

    Science.gov (United States)

    Kazuo Ikeda, K I; Masaki Matsuda, M M; Daisuke Yamauchi, D Y; Katsuro Tomita, K T; Shigenori Tanaka, S T

    2005-07-01

    The purpose of this study is to clarify the reactions of the neuro-muscular junction and nerve cell body to gradual nerve elongation. The sciatic nerves of Japanese white rabbits were lengthened by 30 mm in increments of 0.8 mm/day, 2.0 mm/day and 4.0 mm/day. A scanning electron microscopic examination showed no degenerative change at the neuro-muscular junction, even eight weeks after elongation in the 4-mm group. Hence, neuro-muscular junction is not critical for predicting damage from gradual nerve elongation. There were no axon reaction cells in the 0.8-mm group, a small amount in the 2-mm group, and a large amount in the 4-mm group. The rate of growth associated protein-43 positive nerve cells was significant in the 4-mm group. Hence, the safe speed for nerve cells appeared to be 0.8-mm/day, critical speed to be 2.0-mm/day, and dangerous speed to be 4.0-mm/day in this elongation model.

  18. Comparison of percutaneous electrical nerve stimulation and ultrasound imaging for nerve localization

    NARCIS (Netherlands)

    Wegener, J. T.; Boender, Z. J.; Preckel, B.; Hollmann, M. W.; Stevens, M. F.

    2011-01-01

    Background. Percutaneous nerve stimulation (PNS) is a non-invasive technique to localize superficial nerves before performing peripheral nerve blocks, but its precision has never been evaluated by high-resolution ultrasound. This study compared stimulating points at the skin with the position of

  19. From energy-rich phosphate compounds to warfare agents: A review on the chemistry of organic phosphate compounds

    Directory of Open Access Journals (Sweden)

    Luciano Albino Giusti

    2008-12-01

    Full Text Available The chemistry of the phosphorus-oxygen bond is widely used in biological systems in many processes, such as energy transduction and the storage, transmission and expression of genetic information, which are essential to living beings in relation to a wide variety of functions. Compounds containing this bond have been designed for many purposes, ranging from agricultural defense systems, in order to increase food production, to nerve agents, for complaining use in warfare. In this review, features related to the chemistry of organic phosphate compounds are discussed, with particular emphasis on the role of phosphate compounds in biochemical events and in nerve agents. To this aim, the energy-rich phosphate compounds are focused, particularly the mode of their use as energy currency in cells. Historical and recent studies carried out by research groups have tried to elucidate the mechanism of action of enzymes responsible for energy transduction through the use of biochemical studies, enzyme models, and artificial enzymes. Finally, recent studies on the detoxification of nerve agents based on phosphorous esters are presented, and on the utilization of chromogenic and fluorogenic chemosensors for the detection of these phosphate species.

  20. Imaging the trigeminal nerve

    International Nuclear Information System (INIS)

    Borges, Alexandra; Casselman, Jan

    2010-01-01

    Of all cranial nerves, the trigeminal nerve is the largest and the most widely distributed in the supra-hyoid neck. It provides sensory input from the face and motor innervation to the muscles of mastication. In order to adequately image the full course of the trigeminal nerve and its main branches a detailed knowledge of neuroanatomy and imaging technique is required. Although the main trunk of the trigeminal nerve is consistently seen on conventional brain studies, high-resolution tailored imaging is mandatory to depict smaller nerve branches and subtle pathologic processes. Increasing developments in imaging technique made possible isotropic sub-milimetric images and curved reconstructions of cranial nerves and their branches and led to an increasing recognition of symptomatic trigeminal neuropathies. Whereas MRI has a higher diagnostic yield in patients with trigeminal neuropathy, CT is still required to demonstrate the bony anatomy of the skull base and is the modality of choice in the context of traumatic injury to the nerve. Imaging of the trigeminal nerve is particularly cumbersome as its long course from the brainstem nuclei to the peripheral branches and its rich anastomotic network impede, in most cases, a topographic approach. Therefore, except in cases of classic trigeminal neuralgia, in which imaging studies can be tailored to the root entry zone, the full course of the trigeminal nerve has to be imaged. This article provides an update in the most recent advances on MR imaging technique and a segmental imaging approach to the most common pathologic processes affecting the trigeminal nerve.

  1. Imaging the trigeminal nerve

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandra [Radiology Department, Instituto Portugues de Oncologia Francisco Gentil, Centro de Lisboa, Rua Prof. Lima Basto, 1093, Lisboa (Portugal)], E-mail: borgalexandra@gmail.com; Casselman, Jan [Department of Radiology, A. Z. St Jan Brugge and A. Z. St Augustinus Antwerpen Hospitals (Belgium)

    2010-05-15

    Of all cranial nerves, the trigeminal nerve is the largest and the most widely distributed in the supra-hyoid neck. It provides sensory input from the face and motor innervation to the muscles of mastication. In order to adequately image the full course of the trigeminal nerve and its main branches a detailed knowledge of neuroanatomy and imaging technique is required. Although the main trunk of the trigeminal nerve is consistently seen on conventional brain studies, high-resolution tailored imaging is mandatory to depict smaller nerve branches and subtle pathologic processes. Increasing developments in imaging technique made possible isotropic sub-milimetric images and curved reconstructions of cranial nerves and their branches and led to an increasing recognition of symptomatic trigeminal neuropathies. Whereas MRI has a higher diagnostic yield in patients with trigeminal neuropathy, CT is still required to demonstrate the bony anatomy of the skull base and is the modality of choice in the context of traumatic injury to the nerve. Imaging of the trigeminal nerve is particularly cumbersome as its long course from the brainstem nuclei to the peripheral branches and its rich anastomotic network impede, in most cases, a topographic approach. Therefore, except in cases of classic trigeminal neuralgia, in which imaging studies can be tailored to the root entry zone, the full course of the trigeminal nerve has to be imaged. This article provides an update in the most recent advances on MR imaging technique and a segmental imaging approach to the most common pathologic processes affecting the trigeminal nerve.

  2. Technological advancements for the detection of and protection against biological and chemical warfare agents.

    Science.gov (United States)

    Eubanks, Lisa M; Dickerson, Tobin J; Janda, Kim D

    2007-03-01

    There is a growing need for technological advancements to combat agents of chemical and biological warfare, particularly in the context of the deliberate use of a chemical and/or biological warfare agent by a terrorist organization. In this tutorial review, we describe methods that have been developed both for the specific detection of biological and chemical warfare agents in a field setting, as well as potential therapeutic approaches for treating exposure to these toxic species. In particular, nerve agents are described as a typical chemical warfare agent, and the two potent biothreat agents, anthrax and botulinum neurotoxin, are used as illustrative examples of potent weapons for which countermeasures are urgently needed.

  3. Electrospinning of poly(glycerol sebacate)-based nanofibers for nerve tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jue [College of Textiles, Donghua University, Shanghai 201620 (China); Kai, Dan, E-mail: kaid@imre.a-star.edu.sg [Institute of Materials Research and Engineering (IMRE), A*STAR, 2 Fusionopolis Way, Innovis, #08-03, 138634 (Singapore); Ye, Hongye [Institute of Materials Research and Engineering (IMRE), A*STAR, 2 Fusionopolis Way, Innovis, #08-03, 138634 (Singapore); Tian, Lingling [Centre for Nanofibers and Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 2 Engineering Drive 3 (Singapore); Ding, Xin, E-mail: xding@dhu.edu.cn [College of Textiles, Donghua University, Shanghai 201620 (China); Ramakrishna, Seeram [Centre for Nanofibers and Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 2 Engineering Drive 3 (Singapore); Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou 510632 (China); Loh, Xian Jun, E-mail: lohxj@imre.a-star.edu.sg [Institute of Materials Research and Engineering (IMRE), A*STAR, 2 Fusionopolis Way, Innovis, #08-03, 138634 (Singapore); Department of Materials Science and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576 (Singapore); Singapore Eye Research Institute, 11 Third Hospital Avenue, Singapore 168751 (Singapore)

    2017-01-01

    Nerve tissue engineering (TE) requires biomimetic scaffolds providing essential chemical and topographical cues for nerve regeneration. Poly(glycerol sebacate) (PGS) is a biodegradable and elastic polymer that has gained great interest as a TE scaffolding biomaterial. However, uncured PGS is difficult to be electrospun into nanofibers. PGS would, therefore, require the addition of electrospinning agents. In this study, we modified PGS by using atom transfer radical polymerization (ATRP) to synthesize PGS-based copolymers with methyl methacrylate (MMA). The synthesized PGS-PMMA copolymer showed a molecular weight of 82 kDa and a glass transition temperature of 115 °C. More importantly, the PGS-PMMA could be easily electrospun into nanofiber with a fiber diameter of 167 ± 33 nm. Blending gelatin into PGS-PMMA nanofibers was found to increase its hydrophilicity and biocompatibility. Rat PC12 cells were seeded onto the PGS-PMMA/gelatin nanofibers to investigate their potential for nerve regeneration. It was found that gelatin-containing PGS-based nanofibers promoted cell proliferation. The elongated cell morphology observed on such nanofibers indicated that the scaffolds could induce the neurite outgrowth of the nerve stem cells. Overall, our study suggested that the synthesis of PGS-based copolymers might be a promising approach to enhance their processability, and therefore advancing bioscaffold engineering for various TE applications. - Highlights: • PGS-PMMA copolymers were synthesized by ATRP. • PGS-PMMA nanofibers were fabricated by electrospinning. • PGS-PMMA/gelatin nanofibers promoted cell proliferation and guided stem cell differentiation into nerve cells.

  4. Coevolution of Artificial Agents Using Evolutionary Computation in Bargaining Game

    Directory of Open Access Journals (Sweden)

    Sangwook Lee

    2015-01-01

    Full Text Available Analysis of bargaining game using evolutionary computation is essential issue in the field of game theory. This paper investigates the interaction and coevolutionary process among heterogeneous artificial agents using evolutionary computation (EC in the bargaining game. In particular, the game performance with regard to payoff through the interaction and coevolution of agents is studied. We present three kinds of EC based agents (EC-agent participating in the bargaining game: genetic algorithm (GA, particle swarm optimization (PSO, and differential evolution (DE. The agents’ performance with regard to changing condition is compared. From the simulation results it is found that the PSO-agent is superior to the other agents.

  5. Comparison of trap characteristics between AlGaN/GaN and AlGaN/InGaN/GaN heterostructure by frequency dependent conductance measurement

    International Nuclear Information System (INIS)

    Chakraborty, Apurba; Biswas, Dhrubes

    2015-01-01

    Frequency dependent conductance measurement is carried out to observe the trapping effect in AlGaN/InGaN/GaN double heterostructure and compared that with conventional AlGaN/GaN single heterostructure. It is found that the AlGaN/InGaN/GaN diode structure does not show any trapping effect, whereas single heterostructure AlGaN/GaN diode suffers from two kinds of trap energy states in near depletion to higher negative voltage bias region. This conductance behaviour of AlGaN/InGaN/GaN heterostructure is owing to more Fermi energy level shift from trap energy states at AlGaN/InGaN junction compare to single AlGaN/GaN heterostructure and eliminates the trapping effects. Analysis yielded interface trap energy state in AlGaN/GaN is to be with time constant of (33.8–76.5) μs and trap density of (2.38–0.656) × 10 12  eV −1  cm −2 in −3.2 to −4.8 V bias region, whereas for AlGaN/InGaN/GaN structure no interface energy states are found and the extracted surface trap energy concentrations and time constants are (5.87–4.39) ×10 10  eV −1  cm −2 and (17.8–11.3) μs, respectively, in bias range of −0.8–0.0 V

  6. Transient femoral nerve palsy following ilioinguinal nerve block for ...

    African Journals Online (AJOL)

    Nigerian Journal of Surgery ... Background: Elective inguinal hernia repair in young fit patients is preferably done under ilioinguinal nerve block anesthesia in the ambulatory setting to improve ... Conclusion: TFNP is a rare complication of ilioinguinal nerve block which delays patient discharge postambulatory hernioplasty.

  7. Ulnar nerve damage (image)

    Science.gov (United States)

    The ulnar nerve originates from the brachial plexus and travels down arm. The nerve is commonly injured at the elbow because of elbow fracture or dislocation. The ulnar nerve is near the surface of the body where ...

  8. Chondromyxoid fibroma of the mastoid facial nerve canal mimicking a facial nerve schwannoma.

    Science.gov (United States)

    Thompson, Andrew L; Bharatha, Aditya; Aviv, Richard I; Nedzelski, Julian; Chen, Joseph; Bilbao, Juan M; Wong, John; Saad, Reda; Symons, Sean P

    2009-07-01

    Chondromyxoid fibroma of the skull base is a rare entity. Involvement of the temporal bone is particularly rare. We present an unusual case of progressive facial nerve paralysis with imaging and clinical findings most suggestive of a facial nerve schwannoma. The lesion was tubular in appearance, expanded the mastoid facial nerve canal, protruded out of the stylomastoid foramen, and enhanced homogeneously. The only unusual imaging feature was minor calcification within the tumor. Surgery revealed an irregular, cystic lesion. Pathology diagnosed a chondromyxoid fibroma involving the mastoid portion of the facial nerve canal, destroying the facial nerve.

  9. Femoral nerve damage (image)

    Science.gov (United States)

    The femoral nerve is located in the leg and supplies the muscles that assist help straighten the leg. It supplies sensation ... leg. One risk of damage to the femoral nerve is pelvic fracture. Symptoms of femoral nerve damage ...

  10. End-to-side nerve suture – a technique to repair peripheral nerve ...

    African Journals Online (AJOL)

    Lateral sprouting from an intact nerve into an attached nerve does occur, and functional recovery (sensory and motor) has been demonstrated. We have demonstrated conclusively that ETSNS in the human is a viable option in treating peripheral nerve injuries, including injuries to the brachial plexus. Among the many ...

  11. Military chemical warfare agent human subjects testing: part 2--long-term health effects among participants of U.S. military chemical warfare agent testing.

    Science.gov (United States)

    Brown, Mark

    2009-10-01

    Military chemical warfare agent testing from World War I to 1975 produced thousands of veterans with concerns about how their participation affected their health. A companion article describes the history of these experiments, and how the lack of clinical data hampers evaluation of long-term health consequences. Conversely, much information is available about specific agents tested and their long-term health effects in other populations, which may be invaluable for helping clinicians respond effectively to the health care and other needs of affected veterans. The following review describes tested agents and their known long-term health consequences. Although hundreds of chemicals were tested, they fall into only about a half-dozen pharmaceutical classes, including common pharmaceuticals; anticholinesterase agents including military nerve agents and pesticides; anticholinergic glycolic acid esters such as atropine; acetylcholine reactivators such as 2-PAM; psychoactive compounds including cannabinoids, phencyclidine, and LSD; and irritants including tear gas and riot control agents.

  12. Tumors of the optic nerve

    DEFF Research Database (Denmark)

    Lindegaard, Jens; Heegaard, Steffen

    2009-01-01

    A variety of lesions may involve the optic nerve. Mainly, these lesions are inflammatory or vascular lesions that rarely necessitate surgery but may induce significant visual morbidity. Orbital tumors may induce proptosis, visual loss, relative afferent pupillary defect, disc edema and optic...... atrophy, but less than one-tenth of these tumors are confined to the optic nerve or its sheaths. No signs or symptoms are pathognomonic for tumors of the optic nerve. The tumors of the optic nerve may originate from the optic nerve itself (primary tumors) as a proliferation of cells normally present...... in the nerve (e.g., astrocytes and meningothelial cells). The optic nerve may also be invaded from tumors originating elsewhere (secondary tumors), invading the nerve from adjacent structures (e.g., choroidal melanoma and retinoblastoma) or from distant sites (e.g., lymphocytic infiltration and distant...

  13. Simultaneous central retinal artery occlusion and optic nerve vasculitis in Crohn disease

    Directory of Open Access Journals (Sweden)

    Razek Georges Coussa

    2017-04-01

    Conclusions and importance: To our knowledge, this is the first case of unilateral CRAO and bilateral optic nerve occlusive vasculitis in Crohn disease, which should be considered as an etiology of retinal vascular occlusive disorders especially in young patients. It is important for ophthalmologists to be aware of the ophthalmic risks associated with Crohn disease as aggressive treatment with systemic steroids and immunosuppressive agents is often needed.

  14. Synthesis of a Fluorescently Labeled 68Ga-DOTA-TOC Analog for Somatostatin Receptor Targeting.

    Science.gov (United States)

    Ghosh, Sukhen C; Hernandez Vargas, Servando; Rodriguez, Melissa; Kossatz, Susanne; Voss, Julie; Carmon, Kendra S; Reiner, Thomas; Schonbrunn, Agnes; Azhdarinia, Ali

    2017-07-13

    Fluorescently labeled imaging agents can identify surgical margins in real-time to help achieve complete resections and minimize the likelihood of local recurrence. However, photon attenuation limits fluorescence-based imaging to superficial lesions or lesions that are a few millimeters beneath the tissue surface. Contrast agents that are dual-labeled with a radionuclide and fluorescent dye can overcome this limitation and combine quantitative, whole-body nuclear imaging with intraoperative fluorescence imaging. Using a multimodality chelation (MMC) scaffold, IRDye 800CW was conjugated to the clinically used somatostatin analog, 68 Ga-DOTA-TOC, to produce the dual-labeled analog, 68 Ga-MMC(IRDye 800CW)-TOC, with high yield and specific activity. In vitro pharmacological assays demonstrated retention of receptor-targeting properties for the dual-labeled compound with robust internalization that was somatostatin receptor (SSTR) 2-mediated. Biodistribution studies in mice identified the kidneys as the primary excretion route for 68 Ga-MMC(IRDye 800CW)-TOC, along with clearance via the reticuloendothelial system. Higher uptake was observed in most tissues compared to 68 Ga-DOTA-TOC but decreased as a function of time. The combination of excellent specificity for SSTR2-expressing cells and suitable biodistribution indicate potential application of 68 Ga-MMC(IRDye 800CW)-TOC for intraoperative detection of SSTR2-expressing tumors.

  15. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb.

    Science.gov (United States)

    Kowalska, Berta; Sudoł-Szopińska, Iwona

    2012-06-01

    The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".

  16. Bilateral elevation of interleukin-6 protein and mRNA in both lumbar and cervical dorsal root ganglia following unilateral chronic compression injury of the sciatic nerve

    Czech Academy of Sciences Publication Activity Database

    Dubový, P.; Brázda, Václav; Klusáková, I.; Hradilová-Svíženská, I.

    2013-01-01

    Roč. 10, č. 55 (2013) E-ISSN 1742-2094 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0068 Institutional support: RVO:68081707 Keywords : Unilateral nerve injury * Contralateral reaction * Remote ganglia Subject RIV: BO - Biophysics Impact factor: 4.902, year: 2013

  17. Electrophysiological Assessment of a Peptide Amphiphile Nanofiber Nerve Graft for Facial Nerve Repair.

    Science.gov (United States)

    Greene, Jacqueline J; McClendon, Mark T; Stephanopoulos, Nicholas; Álvarez, Zaida; Stupp, Samuel I; Richter, Claus-Peter

    2018-04-27

    Facial nerve injury can cause severe long-term physical and psychological morbidity. There are limited repair options for an acutely transected facial nerve not amenable to primary neurorrhaphy. We hypothesize that a peptide amphiphile nanofiber neurograft may provide the nanostructure necessary to guide organized neural regeneration. Five experimental groups were compared, animals with 1) an intact nerve, 2) following resection of a nerve segment, and following resection and immediate repair with either a 3) autograft (using the resected nerve segment), 4) neurograft, or 5) empty conduit. The buccal branch of the rat facial nerve was directly stimulated with charge balanced biphasic electrical current pulses at different current amplitudes while nerve compound action potentials (nCAPs) and electromygraphic (EMG) responses were recorded. After 8 weeks, the proximal buccal branch was surgically re-exposed and electrically evoked nCAPs were recorded for groups 1-5. As expected, the intact nerves required significantly lower current amplitudes to evoke an nCAP than those repaired with the neurograft and autograft nerves. For other electrophysiologic parameters such as latency and maximum nCAP, there was no significant difference between the intact, autograft and neurograft groups. The resected group had variable responses to electrical stimulation, and the empty tube group was electrically silent. Immunohistochemical analysis and TEM confirmed myelinated neural regeneration. This study demonstrates that the neuroregenerative capability of peptide amphiphile nanofiber neurografts is similar to the current clinical gold standard method of repair and holds potential as an off-the-shelf solution for facial reanimation and potentially peripheral nerve repair. This article is protected by copyright. All rights reserved.

  18. The success rate of bupivacaine and lidocaine as anesthetic agents in inferior alveolar nerve block in teeth with irreversible pulpitis without spontaneous pain.

    Science.gov (United States)

    Parirokh, Masoud; Yosefi, Mohammad Hosein; Nakhaee, Nouzar; Abbott, Paul V; Manochehrifar, Hamed

    2015-05-01

    Achieving adequate anesthesia with inferior alveolar nerve blocks (IANB) is of great importance during dental procedures. The aim of the present study was to assess the success rate of two anesthetic agents (bupivacaine and lidocaine) for IANB when treating teeth with irreversible pulpitis. Sixty volunteer male and female patients who required root canal treatment of a mandibular molar due to caries participated in the present study. The inclusion criteria included prolonged pain to thermal stimulus but no spontaneous pain. The patients were randomly allocated to receive either 2% lidocaine with 1:80,000 epinephrine or 0.5% bupivacaine with 1:200,000 epinephrine as an IANB injection. The sensitivity of the teeth to a cold test as well as the amount of pain during access cavity preparation and root canal instrumentation were recorded. Results were statistically analyzed with the Chi-Square and Fischer's exact tests. At the final step, fifty-nine patients were included in the study. The success rate for bupivacaine and lidocaine groups were 20.0% and 24.1%, respectively. There was no significant difference between the two groups at any stage of the treatment procedure. There was no difference in success rates of anesthesia when bupivacaine and lidocaine were used for IANB injections to treat mandibular molar teeth with irreversible pulpitis. Neither agent was able to completely anesthetize the teeth effectively. Therefore, practitioners should be prepared to administer supplemental anesthesia to overcome pain during root canal treatment.

  19. Efficacy of ketamine hydrochloride administered as a basilar sesamoid nerve block in alleviating foot pain in horses caused by natural disease.

    Science.gov (United States)

    Schumacher, J; DeGraves, F; Cesar, F; Duran, S

    2014-09-01

    A local anaesthetic agent capable of temporarily resolving lameness after being administered perineurally would be helpful because rapid return of lameness would allow for other analgesic techniques to be performed within a short period of time. To determine if a 3% solution of ketamine hydrochloride (HCl), administered around the palmar nerves at the level of the base of the proximal sesamoid bones, can improve naturally occurring lameness that can be improved or abolished with a basilar sesamoid nerve block performed using lidocaine HCl and to compare the change in gait produced using lidocaine to the change in gait produced using ketamine by using objective lameness assessment. Experimental trial using research horses with naturally occurring lameness. Seven horses, chronically lame on a thoracic limb, were chosen for the study. A wireless, inertial, sensor-based, motion analysis system was used to evaluate lameness before and after administration of 2% lidocaine and later, before and after administration of 3% ketamine over the palmar digital nerves at the base of the proximal sesamoid bones (a basilar sesamoid nerve block) at 5 min intervals for 30 min. Lameness scores obtained before and after administration of lidocaine and ketamine HCl were compared using repeated measures analysis. Gait significantly improved after basilar sesamoid nerve blocks using 2% lidocaine, but gait did not significantly improve after performing the same nerve block using 3% ketamine HCl. Ketamine (3%) administered perineurally for regional anaesthesia of the digit does not desensitise the digit to the same extent as does lidocaine and thus 3% ketamine appears to have no value as a local anaesthetic agent for diagnostic regional anaesthesia. © 2013 EVJ Ltd.

  20. Nerve growth factor receptor immunostaining suggests an extrinsic origin for hypertrophic nerves in Hirschsprung's disease.

    OpenAIRE

    Kobayashi, H; O'Briain, D S; Puri, P

    1994-01-01

    The expression of nerve growth factor receptor in colon from 20 patients with Hirshsprung's disease and 10 controls was studied immunohistochemically. The myenteric and submucous plexuses in the ganglionic bowel and hypertrophic nerve trunks in the aganglionic bowel displayed strong expression of nerve growth factor receptor. The most important finding was the identical localisation of nerve growth factor receptor immunoreactivity on the perineurium of both hypertrophic nerve trunks in Hirshs...

  1. Experimental study of vascularized nerve graft: evaluation of nerve regeneration using choline acetyltransferase activity.

    Science.gov (United States)

    Iwai, M; Tamai, S; Yajima, H; Kawanishi, K

    2001-01-01

    A comparative study of nerve regeneration was performed on vascularized nerve graft (VNG) and free nerve graft (FNG) in Fischer strain rats. A segment of the sciatic nerve with vascular pedicle of the femoral artery and vein was harvested from syngeneic donor rat for the VNG group and the sciatic nerve in the same length without vascular pedicle was harvested for the FNG group. They were transplanted to a nerve defect in the sciatic nerve of syngeneic recipient rats. At 2, 4, 6, 8, 12, 16, and 24 weeks after operation, the sciatic nerves were biopsied and processed for evaluation of choline acetyltransferase (CAT) activity, histological studies, and measurement of wet weight of the muscle innervated by the sciatic nerve. Electrophysiological evaluation of the grafted nerve was also performed before sacrifice. The average CAT activity in the distal to the distal suture site was 383 cpm in VNG and 361 cpm in FNG at 2 weeks; 6,189 cpm in VNG and 2,264 cpm in FNG at 4 weeks; and 11,299 cpm in VNG and 9,424 cpm in FNG at 6 weeks postoperatively. The value of the VNG group was statistically higher than that of the FNG group at 4 weeks postoperatively. Electrophysiological and histological findings also suggested that nerve regeneration in the VNG group was superior to that in the FNG group during the same period. However, there was no significant difference between the two groups after 6 weeks postoperatively in any of the evaluations. The CAT measurement was useful in the experiments, because it was highly sensitive and reproducible. Copyright 2001 Wiley-Liss, Inc.

  2. Characterization of chemical agent transport in paints.

    Science.gov (United States)

    Willis, Matthew P; Gordon, Wesley; Lalain, Teri; Mantooth, Brent

    2013-09-15

    A combination of vacuum-based vapor emission measurements with a mass transport model was employed to determine the interaction of chemical warfare agents with various materials, including transport parameters of agents in paints. Accurate determination of mass transport parameters enables the simulation of the chemical agent distribution in a material for decontaminant performance modeling. The evaluation was performed with the chemical warfare agents bis(2-chloroethyl) sulfide (distilled mustard, known as the chemical warfare blister agent HD) and O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (VX), an organophosphate nerve agent, deposited on to two different types of polyurethane paint coatings. The results demonstrated alignment between the experimentally measured vapor emission flux and the predicted vapor flux. Mass transport modeling demonstrated rapid transport of VX into the coatings; VX penetrated through the aliphatic polyurethane-based coating (100 μm) within approximately 107 min. By comparison, while HD was more soluble in the coatings, the penetration depth in the coatings was approximately 2× lower than VX. Applications of mass transport parameters include the ability to predict agent uptake, and subsequent long-term vapor emission or contact transfer where the agent could present exposure risks. Additionally, these parameters and model enable the ability to perform decontamination modeling to predict how decontaminants remove agent from these materials. Published by Elsevier B.V.

  3. Effect of platelet rich plasma and fibrin sealant on facial nerve regeneration in a rat model.

    Science.gov (United States)

    Farrag, Tarik Y; Lehar, Mohamed; Verhaegen, Pauline; Carson, Kathryn A; Byrne, Patrick J

    2007-01-01

    agents (PPP). FS showed no benefit over conventional suturing in facial nerve regeneration. Our study provides the potential of a new clinical application for PRP in peripheral nerve regeneration.

  4. Recurrent unilateral facial nerve palsy in a child with dehiscent facial nerve canal

    Directory of Open Access Journals (Sweden)

    Christopher Liu

    2016-12-01

    Full Text Available Objective: The dehiscent facial nerve canal has been well documented in histopathological studies of temporal bones as well as in clinical setting. We describe clinical and radiologic features of a child with recurrent facial nerve palsy and dehiscent facial nerve canal. Methods: Retrospective chart review. Results: A 5-year-old male was referred to the otolaryngology clinic for evaluation of recurrent acute otitis media and hearing loss. He also developed recurrent left peripheral FN palsy associated with episodes of bilateral acute otitis media. High resolution computed tomography of the temporal bones revealed incomplete bony coverage of the tympanic segment of the left facial nerve. Conclusions: Recurrent peripheral FN palsy may occur in children with recurrent acute otitis media in the presence of a dehiscent facial nerve canal. Facial nerve canal dehiscence should be considered in the differential diagnosis of children with recurrent peripheral FN palsy.

  5. Reconstruction of the abdominal vagus nerve using sural nerve grafts in canine models.

    Science.gov (United States)

    Liu, Jingbo; Wang, Jun; Luo, Fen; Wang, Zhiming; Wang, Yin

    2013-01-01

    Recently, vagus nerve preservation or reconstruction of vagus has received increasing attention. The present study aimed to investigate the feasibility of reconstructing the severed vagal trunk using an autologous sural nerve graft. Ten adult Beagle dogs were randomly assigned to two groups of five, the nerve grafting group (TG) and the vagal resection group (VG). The gastric secretion and emptying functions in both groups were assessed using Hollander insulin and acetaminophen tests before surgery and three months after surgery. All dogs underwent laparotomy under general anesthesia. In TG group, latency and conduction velocity of the action potential in a vagal trunk were measured, and then nerves of 4 cm long were cut from the abdominal anterior and posterior vagal trunks. Two segments of autologous sural nerve were collected for performing end-to-end anastomoses with the cut ends of vagal trunk (8-0 nylon suture, 3 sutures for each anastomosis). Dogs in VG group only underwent partial resections of the anterior and posterior vagal trunks. Laparotomy was performed in dogs of TG group, and latency and conduction velocity of the action potential in their vagal trunks were measured. The grafted nerve segment was removed, and stained with anti-neurofilament protein and toluidine blue. Latency of the action potential in the vagal trunk was longer after surgery than before surgery in TG group, while the conduction velocity was lower after surgery. The gastric secretion and emptying functions were weaker after surgery in dogs of both groups, but in TG group they were significantly better than in VG group. Anti-neurofilament protein staining and toluidine blue staining showed there were nerve fibers crossing the anastomosis of the vagus and sural nerves in dogs of TG group. Reconstruction of the vagus nerve using the sural nerve is technically feasible.

  6. Reconstruction of the abdominal vagus nerve using sural nerve grafts in canine models.

    Directory of Open Access Journals (Sweden)

    Jingbo Liu

    Full Text Available BACKGROUND: Recently, vagus nerve preservation or reconstruction of vagus has received increasing attention. The present study aimed to investigate the feasibility of reconstructing the severed vagal trunk using an autologous sural nerve graft. METHODS: Ten adult Beagle dogs were randomly assigned to two groups of five, the nerve grafting group (TG and the vagal resection group (VG. The gastric secretion and emptying functions in both groups were assessed using Hollander insulin and acetaminophen tests before surgery and three months after surgery. All dogs underwent laparotomy under general anesthesia. In TG group, latency and conduction velocity of the action potential in a vagal trunk were measured, and then nerves of 4 cm long were cut from the abdominal anterior and posterior vagal trunks. Two segments of autologous sural nerve were collected for performing end-to-end anastomoses with the cut ends of vagal trunk (8-0 nylon suture, 3 sutures for each anastomosis. Dogs in VG group only underwent partial resections of the anterior and posterior vagal trunks. Laparotomy was performed in dogs of TG group, and latency and conduction velocity of the action potential in their vagal trunks were measured. The grafted nerve segment was removed, and stained with anti-neurofilament protein and toluidine blue. RESULTS: Latency of the action potential in the vagal trunk was longer after surgery than before surgery in TG group, while the conduction velocity was lower after surgery. The gastric secretion and emptying functions were weaker after surgery in dogs of both groups, but in TG group they were significantly better than in VG group. Anti-neurofilament protein staining and toluidine blue staining showed there were nerve fibers crossing the anastomosis of the vagus and sural nerves in dogs of TG group. CONCLUSION: Reconstruction of the vagus nerve using the sural nerve is technically feasible.

  7. Electrophysiology of Extraocular Cranial Nerves: Oculomotor, Trochlear, and Abducens Nerve.

    Science.gov (United States)

    Hariharan, Praveen; Balzer, Jeffery R; Anetakis, Katherine; Crammond, Donald J; Thirumala, Parthasarathy D

    2018-01-01

    The utility of extraocular cranial nerve electrophysiologic recordings lies primarily in the operating room during skull base surgeries. Surgical manipulation during skull base surgeries poses a risk of injury to multiple cranial nerves, including those innervating extraocular muscles. Because tumors distort normal anatomic relationships, it becomes particularly challenging to identify cranial nerve structures. Studies have reported the benefits of using intraoperative spontaneous electromyographic recordings and compound muscle action potentials evoked by electrical stimulation in preventing postoperative neurologic deficits. Apart from surgical applications, electromyography of extraocular muscles has also been used to guide botulinum toxin injections in patients with strabismus and as an adjuvant diagnostic test in myasthenia gravis. In this article, we briefly review the rationale, current available techniques to monitor extraocular cranial nerves, technical difficulties, clinical and surgical applications, as well as future directions for research.

  8. Conjoined lumbosacral nerve roots

    International Nuclear Information System (INIS)

    Kyoshima, Kazumitsu; Nishiura, Iwao; Koyama, Tsunemaro

    1986-01-01

    Several kinds of the lumbosacral nerve root anomalies have already been recognized, and the conjoined nerve roots is the most common among them. It does not make symptoms by itself, but if there is a causation of neural entrapment, for example, disc herniation, lateral recessus stenosis, spondylolisthesis, etc., so called ''biradicular syndrome'' should occur. Anomalies of the lumbosacral nerve roots, if not properly recognized, may lead to injury of these nerves during operation of the lumbar spine. Recently, the chance of finding these anomalous roots has been increased more and more with the use of metrizamide myelography and metrizamide CT, because of the improvement of the opacification of nerve roots. We describe the findings of the anomalous roots as revealed by these two methods. They demonstrate two nerve roots running parallel and the asymmetrical wide root sleeve. Under such circumstances, it is important to distinguish the anomalous roots from the normal ventral and dorsal roots. (author)

  9. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    Science.gov (United States)

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  10. Formation of GaAs/AlGaAs and InGaAs/GaAs nanorings by droplet molecular-beam epitaxy

    International Nuclear Information System (INIS)

    Gong, Z.; Niu, Z.C.; Huang, S.S.; Fang, Z.D.; Sun, B.Q.; Xia, J.B.

    2005-01-01

    GaAs/AlGaAs lattice-matched nanorings are formed on GaAs (100) substrates by droplet epitaxy. The crucial step in the formation of nanorings is annealing Ga droplets under As flux for proper time. The observed morphologic evolution of Ga droplets during annealing does not support the hypothesis that As atoms preferentially react with Ga around the periphery of the droplets, but somehow relates to a dewetting process similar to that of unstable films. Photoluminescene (PL) test results confirm the quantum-confinement effect of these GaAs nanorings. Using similar methods, we have fabricated InGaAs/GaAs lattice-mismatched rings

  11. Secondary digital nerve repair in the foot with resorbable p(DLLA-epsilon-CL) nerve conduits

    NARCIS (Netherlands)

    Meek, MF; Nicolai, JPA; Robinson, PH

    Nerve guides are increasingly being used in peripheral nerve repair. In the last decade, Much preclinical research has been undertaken into a resorbable nerve guide composed of p(DLLA-epsilon-CL). This report describes the results of secondary digital nerve reconstruction in the foot in a patient

  12. Nerve conduction velocity

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003927.htm Nerve conduction velocity To use the sharing features on this page, please enable JavaScript. Nerve conduction velocity (NCV) is a test to see ...

  13. Spatially resolved In and As distributions in InGaAs/GaP and InGaAs/GaAs quantum dot systems

    International Nuclear Information System (INIS)

    Shen, J; Cha, J J; Song, Y; Lee, M L

    2014-01-01

    InGaAs quantum dots (QDs) on GaP are promising for monolithic integration of optoelectronics with Si technology. To understand and improve the optical properties of InGaAs/GaP QD systems, detailed measurements of the QD atomic structure as well as the spatial distributions of each element at high resolution are crucial. This is because the QD band structure, band alignment, and optical properties are determined by the atomic structure and elemental composition. Here, we directly measure the inhomogeneous distributions of In and As in InGaAs QDs grown on GaAs and GaP substrates at the nanoscale using energy dispersive x-ray spectral mapping in a scanning transmission electron microscope. We find that the In distribution is broader on GaP than on GaAs, and as a result, the QDs appear to be In-poor using a GaP matrix. Our findings challenge some of the assumptions made for the concentrations and distributions of In within InGaAs/GaAs or InGaAs/GaP QD systems and provide detailed structural and elemental information to modify the current band structure understanding. In particular, the findings of In deficiency and inhomogeneous distribution in InGaAs/GaP QD systems help to explain photoluminescence spectral differences between InGaAs/GaAs and InGaAs/GaP QD systems. (paper)

  14. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection.

    Science.gov (United States)

    Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi

    2008-01-01

    Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  15. [Does intraoperative nerve monitoring reduce the rate of recurrent nerve palsies during thyroid surgery?].

    Science.gov (United States)

    Timmermann, W; Dralle, H; Hamelmann, W; Thomusch, O; Sekulla, C; Meyer, Th; Timm, S; Thiede, A

    2002-05-01

    Two different aspects of the influence of neuromonitoring on the possible reduction of post-operative recurrent laryngeal nerve palsies require critical examination: the nerve identification and the monitoring of it's functions. Due to the additional information from the EMG signals, neuromonitoring is the best method for identifying the nerves as compared to visual identification alone. There are still no randomized studies available that compare the visual and electrophysiological recurrent laryngeal nerve detection in thyroid operations with respect to the postoperative nerve palsies. Nevertheless, comparisons with historical collectives show that a constant low nerve-palsy-rate was achieved with electrophysiological detection in comparison to visual detection. The rate of nerve identification is normally very high and amounts to 99 % in our own patients. The data obtained during the "Quality assurance of benign and malignant Goiter" study show that in hemithyreoidectomy and subtotal resection, lower nerve-palsy-rates are achieved with neuromonitoring as compared to solely visual detection. Following subtotal resection, this discrepancy becomes even statistically significant. While monitoring the nerve functions with the presently used neuromonitoring technique, it is possible to observe the EMG-signal remaining constant or decreasing in volume. Assuming that a constant neuromonitoring signal represents a normal vocal cord, our evaluation shows that there is a small percentage of false negative and positive results. Looking at the permanent recurrent nerve palsy rates, this method has a specificity of 98 %, a sensitivity of 100 %, a positive prognostic value of 10 %, and a negative prognostic value of 100 %. Although an altered neuromonitoring signal can be taken as a clear indication of eventual nerve damage, an absolutely reliable statement about the postoperative vocal cord function is presently not possible with intraoperative neuromonitoring.

  16. Fabrication of nerve guidance conduit with luminal filler as scaffold for peripheral nerve repair

    International Nuclear Information System (INIS)

    Aranilla, Charito T.; Wach, Rodoslaw; Ulanski, Piotr

    2015-01-01

    Peripheral nerve injury is a serious health concern for society, affecting trauma patients, many of whom acquire life-long disability. The gold standard of treatment for peripheral nerve injury is the use of nerve grafts, wherein nerve autograft or allograft is used to bridge the gap in the damaged nerve. Nerve guidance conduits (NGCs) are an attractive alternative to nerve autografts for aiding in the regeneration of peripheral nerve tissue. NGCs are small cylinders or tubes composed of either natural or synthetic biomaterials that are used to axon regeneration. The ends of the damaged nerve are inserted into either end of the cylinder and the NGC acts both as a connecting bridge for the severed nerve ends as well as a protective shelter for the regenerating nerve. This study aims at fabricating nerve guidance conduits with luminal structure based on synthetic biodegradable and biocompatible polymers such as poly (trimethylene carbonate ) (PTMC), poly (lactic acid) (PLA) and poly (caprolactone) (PCL). Initial base materials for fabrication were PLA acid tubes compared to PCL tubes when prepared by spray and dip-coating methods. The morphology of the tubes where examined by SEM and results showed better porosity of PLA acid tubes compared to PCL tubes when prepared by spraying technique. Poly(lactic acid) was then blended with poly(trimethylene carbonate) at a ratio of 1:4 (5% total polymer content) for further fabrication. Electron beam radiation (25 and 50 kGy) was employed for sterilization and the changes in properties induced by irradiation in comprising polymers were evaluated. The wettability, mechanical thermal properties were not significantly changed by irradiation.In a separate experiment, synthesis of carboxymethyl chitosan hydrogel crosslinked by electron beam radiation was studied to create a luminal filler for PTMC-PLA tubes. Based on proper viscosity of solution before crosslinking, sufficient gel fraction and swelling, 10% w/v concentration of

  17. Laser-based instrumentation for the detection of chemical agents

    International Nuclear Information System (INIS)

    Hartford, A. Jr.; Sander, R.K.; Quigley, G.P.; Radziemski, L.J.; Cremers, D.A.

    1982-01-01

    Several laser-based techniques are being evaluated for the remote, point, and surface detection of chemical agents. Among the methods under investigation are optoacoustic spectroscopy, laser-induced breakdown spectroscopy (LIBS), and synchronous detection of laser-induced fluorescence (SDLIF). Optoacoustic detection has already been shown to be capable of extremely sensitive point detection. Its application to remote sensing of chemical agents is currently being evaluated. Atomic emission from the region of a laser-generated plasma has been used to identify the characteristic elements contained in nerve (P and F) and blister (S and Cl) agents. Employing this LIBS approach, detection of chemical agent simulants dispersed in air and adsorbed on a variety of surfaces has been achieved. Synchronous detection of laser-induced fluorescence provides an attractive alternative to conventional LIF, in that an artificial narrowing of the fluorescence emission is obtained. The application of this technique to chemical agent simulants has been successfully demonstrated. 19 figures

  18. NERVE REGENERATION THROUGH A 2-PLY BIODEGRADABLE NERVE GUIDE IN THE RAT AND THE INFLUENCE OF ACTH4-9 NERVE GROWTH-FACTOR

    NARCIS (Netherlands)

    ROBINSON, PH; VANDERLEI, B; HOPPEN, HJ; LEENSLAG, JW; PENNINGS, AJ; NIEUWENHUIS, P

    1991-01-01

    Biodegradable polyurethane-based (PU) nerve guides, instilled with or without ACTH4-9 analog (a melanocortin) were used for bridging an 8 mm gap in the rat sciatic nerve and were evaluated for function and histological appearance after 16 weeks of implantation. Autologous nerve grafts functioned as

  19. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”.

  20. In vivo evaluation of a radiogallium-labeled bifunctional radiopharmaceutical, Ga-DOTA-MN2, for hypoxic tumor imaging.

    Science.gov (United States)

    Sano, Kohei; Okada, Mayumi; Hisada, Hayato; Shimokawa, Kenta; Saji, Hideo; Maeda, Minoru; Mukai, Takahiro

    2013-01-01

    On the basis of the findings obtained by X-ray crystallography of Ga-DOTA chelates and the drug design concept of bifunctional radiopharmaceuticals, we previously designed and synthesized a radiogallium-labeled DOTA chelate containing two metronidazole moieties, (67)Ga-DOTA-MN2, for hypoxic tumor imaging. As expected, (67)Ga-DOTA-MN2 exhibited high in vivo stability, although two carboxyl groups in the DOTA skeleton were conjugated with metronidazole moieties. In this study, we evaluated (67/68)Ga-DOTA-MN2 as a nuclear imaging agent for hypoxic tumors. (67)Ga-labeling of DOTA-MN2 with (67)GaCl(3) was achieved with high radiochemical yield (>85%) by 1-min of microwave irradiation (50 W). The pharmacokinetics of (67)Ga-DOTA-MN2 were examined in FM3A tumor-bearing mice, and compared with those of (67)Ga-DOTA-MN1 containing one metronidazole unit and (67)Ga-DOTA. Upon administration, (67)Ga-DOTA-MN2 exhibited higher accumulation in the implanted tumors than (67)Ga-DOTA. Tumor-to-blood ratios of (67)Ga-DOTA-MN2 were about two-fold higher than those of (67)Ga-DOTA-MN1. Autoradiographic analysis showed the heterogeneous localization of (67)Ga-DOTA-MN2 in the tumors, which corresponds to hypoxic regions suggested by well-established hypoxia marker drug, pimonidazole. Furthermore, in positron emission tomography (PET) study, the tumors of mice administered (68)Ga-labeled DOTA-MN2 were clearly imaged by small-animal PET at 1 h after administration. This study demonstrates the potential usefulness of (67/68)Ga-DOTA-MN2 as a nuclear imaging agent for hypoxic tumors and suggests that two functional moieties, such as metronidazole, can be conjugated to radiogallium-DOTA chelate without reducing the complex stability. The present findings provide useful information about the chemical design of radiogallium-labeled radiopharmaceuticals for PET and single photon emission computed tomography (SPECT) studies.

  1. Neuromuscular ultrasound of cranial nerves.

    Science.gov (United States)

    Tawfik, Eman A; Walker, Francis O; Cartwright, Michael S

    2015-04-01

    Ultrasound of cranial nerves is a novel subdomain of neuromuscular ultrasound (NMUS) which may provide additional value in the assessment of cranial nerves in different neuromuscular disorders. Whilst NMUS of peripheral nerves has been studied, NMUS of cranial nerves is considered in its initial stage of research, thus, there is a need to summarize the research results achieved to date. Detailed scanning protocols, which assist in mastery of the techniques, are briefly mentioned in the few reference textbooks available in the field. This review article focuses on ultrasound scanning techniques of the 4 accessible cranial nerves: optic, facial, vagus and spinal accessory nerves. The relevant literatures and potential future applications are discussed.

  2. Musculocutaneous nerve substituting for the distal part of radial nerve: A case report and its embryological basis

    Directory of Open Access Journals (Sweden)

    A S Yogesh

    2011-01-01

    Full Text Available In the present case, we have reported a unilateral variation of the radial and musculocutaneous nerves on the left side in a 64-year-old male cadaver. The radial nerve supplied all the heads of the triceps brachii muscle and gave cutaneous branches such as lower lateral cutaneous nerve of the arm and posterior cutaneous nerve of forearm. The radial nerve ended without continuing further. The musculocutaneous nerve supplied the brachioradialis, extensor carpi radialis longus and extensor carpi radialis brevis muscles. The musculocutaneous nerve divided terminally into two branches, superficial and deep. The deep branch of musculocutaneous nerve corresponded to usual deep branch of the radial nerve while the superficial branch of musculocutaneous nerve corresponded to usual superficial branch of the radial nerve. The dissection was continued to expose the entire brachial plexus from its origin and it was found to be normal. The structures on the right upper limb were found to be normal. Surgeons should keep such variations in mind while performing the surgeries of the upper limb.

  3. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  4. Diagnostic value of the near-nerve needle sensory nerve conduction in sensory inflammatory demyelinating polyneuropathy.

    Science.gov (United States)

    Odabasi, Zeki; Oh, Shin J

    2018-03-01

    In this study we report the diagnostic value of the near-nerve needle sensory nerve conduction study (NNN-SNCS) in sensory inflammatory demyelinating polyneuropathy (IDP) in which the routine nerve conduction study was normal or non-diagnostic. The NNN-SNCS was performed to identify demyelination in the plantar nerves in 14 patients and in the median or ulnar nerve in 2 patients with sensory IDP. In 16 patients with sensory IDP, routine NCSs were either normal or non-diagnostic for demyelination. Demyelination was identified by NNN-SNCS by dispersion and/or slow nerve conduction velocity (NCV) below the demyelination marker. Immunotherapy was initiated in 11 patients, 10 of whom improved or remained stable. NNN-SNCS played an essential role in identifying demyelinaton in 16 patients with sensory IDP, leading to proper treatment. Muscle Nerve 57: 414-418, 2018. © 2017 Wiley Periodicals, Inc.

  5. Interfascicular suture with nerve autografts for median, ulnar and radial nerve lesions.

    Science.gov (United States)

    Pluchino, F; Luccarelli, G

    1981-05-01

    Interfascicular nerve suture with autografts is the operation of choice for repairing peripheral nerve injuries because it ensures more precise alignment of the fasciculi and so better chances of reinnervation of the sectioned nerve. The procedure as described by Millesi et al has been used at the Istituto Neurologico di Milano in 30 patients with traumatic lesions of the median, ulnar and radial nerves. All have been followed up for 2 to 7 years since operation. The results obtained are compared with those of other series obtained with interfascicular suture and with epineural suture. Microsurgery is essential. The best time to operate is discussed.

  6. Comparison of Binding Affinities of Water-Soluble Calixarenes with the Organophosphorus Nerve Agent Soman (GD and Commonly-Used Nerve Agent Simulants

    Directory of Open Access Journals (Sweden)

    Jayne A. Ede

    2018-01-01

    Full Text Available The formation of inclusion complexes of the water-soluble p-sulfonatocalix[n]arenes, where n = 4 or 6, with the Chemical Warfare Agent (CWA GD, or Soman, and commonly used dialkyl methylphosphonate simulants has been studied by experimental solution NMR methods and by Molecular Mechanics (MMFF and semi-empirical (PM6 calculations. Complex formation in non-buffered and buffered solutions is driven by the hydrophobic effect, and complex stoichiometry determined as 1:1 for all host:guest pairs. Low affinity complexes (Kassoc < 100 M−1 are observed for all guests, attributed to poor host–guest complementarity and the role of buffer cation species accounts for the low affinity of the complexes. Comparison of CWA and simulant behavior adds to understanding of CWA–simulant correlations and the challenges of simulant selection.

  7. Chemoattractive capacity of different lengths of nerve fragments bridging regeneration chambers for the repair of sciatic nerve defects

    Institute of Scientific and Technical Information of China (English)

    Jiren Zhang; Yubo Wang; Jincheng Zhang

    2012-01-01

    A preliminary study by our research group showed that 6-mm-long regeneration chamber bridging is equivalent to autologous nerve transplantation for the repair of 12-mm nerve defects.In this study,we compared the efficacy of different lengths (6,8,10 mm) of nerve fragments bridging 6-mm regeneration chambers for the repair of 12-mm-long nerve defects.At 16 weeks after the regeneration chamber was implanted,the number,diameter and myelin sheath thickness of the regenerated nerve fibers,as well as the conduction velocity of the sciatic nerve and gastrocnemius muscle wet weight ratio,were similar to that observed with autologous nerve transplantation.Our results demonstrate that 6-,8-and 10-mm-long nerve fragments bridging 6-mm regeneration chambers effectively repair 12-mm-long nerve defects.Because the chemoattractive capacity is not affected by the length of the nerve fragment,we suggest adopting 6-mm-long nerve fragments for the repair of peripheral nerve defects.

  8. Preparation and Biological Study of (68)Ga-DOTA-alendronate.

    Science.gov (United States)

    Fakhari, Ashraf; Jalilian, Amir R; Johari-Daha, Fariba; Shafiee-Ardestani, Mehdi; Khalaj, Ali

    2016-01-01

    In line with previous research on the development of conjugated bisphosphonate ligands as new bone-avid agents, in this study, DOTA-conjugated alendronate (DOTA-ALN) was synthesized and evaluated after labeling with gallium-68 ((68)Ga). DOTA-ALN was synthesized and characterized, followed by (68)Ga-DOTA-ALN preparation, using DOTA-ALN and (68)GaCl3 (pH: 4-5) at 92-95° C for 10 min. Stability tests, hydroxyapatite assay, partition coefficient calculation, biodistribution studies, and imaging were performed on the developed agent in normal rats. The complex was prepared with high radiochemical purity (>99% as depicted by radio thin-layer chromatography; specific activity: 310-320 GBq/mmol) after solid phase purification and was stabilized for up to 90 min with a log P value of -2.91. Maximum ligand binding (65%) was observed in the presence of 50 mg of hydroxyapatite; a major portion of the activity was excreted through the kidneys. With the exception of excretory organs, gastrointestinal tract organs, including the liver, intestine, and colon, showed significant uptake; however, the bone uptake was low (<1%) at 30 min after the injection. The data were also confirmed by sequential imaging at 30-90 min following the intravenous injection. The high solubility and anionic properties of the complex led to major renal excretion and low hydroxyapatite uptake; therefore, the complex failed to demonstrate bone imaging behaviors.

  9. Effect of Surface Pore Structure of Nerve Guide Conduit on Peripheral Nerve Regeneration

    Science.gov (United States)

    Oh, Se Heang; Kim, Jin Rae; Kwon, Gu Birm; Namgung, Uk; Song, Kyu Sang

    2013-01-01

    Polycaprolactone (PCL)/Pluronic F127 nerve guide conduits (NGCs) with different surface pore structures (nano-porous inner surface vs. micro-porous inner surface) but similar physical and chemical properties were fabricated by rolling the opposite side of asymmetrically porous PCL/F127 membranes. The effect of the pore structure on peripheral nerve regeneration through the NGCs was investigated using a sciatic nerve defect model of rats. The nerve fibers and tissues were shown to have regenerated along the longitudinal direction through the NGC with a nano-porous inner surface (Nanopore NGC), while they grew toward the porous wall of the NGC with a micro-porous inner surface (Micropore NGC) and, thus, their growth was restricted when compared with the Nanopore NGC, as investigated by immunohistochemical evaluations (by fluorescence microscopy with anti-neurofilament staining and Hoechst staining for growth pattern of nerve fibers), histological evaluations (by light microscopy with Meyer's modified trichrome staining and Toluidine blue staining and transmission electron microscopy for the regeneration of axon and myelin sheath), and FluoroGold retrograde tracing (for reconnection between proximal and distal stumps). The effect of nerve growth factor (NGF) immobilized on the pore surfaces of the NGCs on nerve regeneration was not so significant when compared with NGCs not containing immobilized NGF. The NGC system with different surface pore structures but the same chemical/physical properties seems to be a good tool that is used for elucidating the surface pore effect of NGCs on nerve regeneration. PMID:22871377

  10. Anatomy of pudendal nerve at urogenital diaphragm--new critical site for nerve entrapment.

    Science.gov (United States)

    Hruby, Stephan; Ebmer, Johannes; Dellon, A Lee; Aszmann, Oskar C

    2005-11-01

    To investigate the relations of the pudendal nerve in this complex anatomic region and determine possible entrapment sites that are accessible for surgical decompression. Entrapment neuropathies of the pudendal nerve are an uncommon and, therefore, often overlooked or misdiagnosed clinical entity. The detailed relations of this nerve as it exits the pelvis through the urogenital diaphragm and enters the mobile part of the penis have not yet been studied. Detailed anatomic dissections were performed in 10 formalin preserved hemipelves under 3.5x loupe magnification. The pudendal nerve was dissected from the entrance into the Alcock canal to the dorsum of the penis. The branching pattern of the nerve and its topographic relationship were recorded and photographs taken. The anatomic dissections revealed that the pudendal nerve passes through a tight osteofibrotic canal just distal to the urogenital diaphragm at the entrance to the base of the penis. This canal is, in part, formed by the inferior ramus of the pubic bone, the suspensory ligament of the penis, and the ischiocavernous body. In two specimens, a fusiform pseudoneuromatous thickening was found. The pudendal nerve is susceptible to compression at the passage from the Alcock canal to the dorsum of the penis. Individuals exposed to repetitive mechanical irritation in this region are especially endangered. Diabetic patients with peripheral neuropathy can have additional compression neuropathy with decreased penile sensibility and will benefit from decompression of the pudendal nerve.

  11. Adult Stem Cell-Based Enhancement of Nerve Conduit for Peripheral Nerve Repair

    Science.gov (United States)

    2017-10-01

    acceptable donor nerves are often not available for this purpose, particularly in patients suffering multiple extremity injuries or faced with traumatic...amputations. Alternatives include the use of a blood vessel graft or a synthetic nerve guide, although these devices are only effective over distances less...of combat-related orthopaedic trauma. Given the severity of the orthopaedic injuries sustained during battlefield trauma, an acceptable donor nerve is

  12. Degenerative Nerve Diseases

    Science.gov (United States)

    Degenerative nerve diseases affect many of your body's activities, such as balance, movement, talking, breathing, and heart function. Many ... viruses. Sometimes the cause is not known. Degenerative nerve diseases include Alzheimer's disease Amyotrophic lateral sclerosis Friedreich's ...

  13. Dynamical agents' strategies and the fractal market hypothesis

    Czech Academy of Sciences Publication Activity Database

    Vácha, Lukáš; Vošvrda, Miloslav

    2005-01-01

    Roč. 14, č. 2 (2005), s. 172-179 ISSN 1210-0455 Grant - others:GA UK(CZ) 454/2004/A EK/FSV Institutional research plan: CEZ:AV0Z10750506 Keywords : efficient market hypothesis * fractal market hypothesis * agent's investment horizons Subject RIV: AH - Economics

  14. Delayed repair of the peripheral nerve: a novel model in the rat sciatic nerve.

    Science.gov (United States)

    Wu, Peng; Spinner, Robert J; Gu, Yudong; Yaszemski, Michael J; Windebank, Anthony J; Wang, Huan

    2013-03-30

    Peripheral nerve reconstruction is seldom done in the acute phase of nerve injury due to concomitant injuries and the uncertainty of the extent of nerve damage. A proper model that mimics true clinical scenarios is critical but lacking. The aim of this study is to develop a standardized, delayed sciatic nerve repair model in rats and validate the feasibility of direct secondary neurrorraphy after various delay intervals. Immediately or 1, 4, 6, 8 and 12 weeks after sciatic nerve transection, nerve repair was carried out. A successful tension-free direct neurorraphy (TFDN) was defined when the gap was shorter than 4.0 mm and the stumps could be reapproximated with 10-0 stitches without detachment. Compound muscle action potential (CMAP) was recorded postoperatively. Gaps between the two nerve stumps ranged from 0 to 9 mm, the average being 1.36, 2.85, 3.43, 3.83 and 6.4 mm in rats with 1, 4, 6, 8 and 12 week delay, respectively. The rate of successful TFDN was 78% overall. CMAP values of 1 and 4 week delay groups were not different from the immediate repair group, whereas CMAP amplitudes of 6, 8 and 12 week delay groups were significantly lower. A novel, standardized delayed nerve repair model is established. For this model to be sensitive, the interval between nerve injury and secondary repair should be at least over 4 weeks. Thereafter the longer the delay, the more challenging the model is for nerve regeneration. The choice of delay intervals can be tailored to meet specific requirements in future studies. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Pathology of the vestibulocochlear nerve

    Energy Technology Data Exchange (ETDEWEB)

    De Foer, Bert [Department of Radiology, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium)], E-mail: bert.defoer@GZA.be; Kenis, Christoph [Department of Radiology, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium)], E-mail: christophkenis@hotmail.com; Van Melkebeke, Deborah [Department of Neurology, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium)], E-mail: Deborah.vanmelkebeke@Ugent.be; Vercruysse, Jean-Philippe [University Department of ENT, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium)], E-mail: jphver@yahoo.com; Somers, Thomas [University Department of ENT, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium)], E-mail: Thomas.somers@GZA.be; Pouillon, Marc [Department of Radiology, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium)], E-mail: marc.pouillon@GZA.be; Offeciers, Erwin [University Department of ENT, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium)], E-mail: Erwin.offeciers@GZA.be; Casselman, Jan W. [Department of Radiology, AZ Sint-Jan AV Hospital, Ruddershove 10, Bruges (Belgium); Consultant Radiologist, Sint-Augustinus Hospital, Oosterveldlaan 24, 2610 Wilrijk (Belgium); Academic Consultent, University of Ghent (Belgium)], E-mail: jan.casselman@azbrugge.be

    2010-05-15

    There is a large scala of pathology affecting the vestibulocochlear nerve. Magnetic resonance imaging is the method of choice for the investigation of pathology of the vestibulocochlear nerve. Congenital pathology mainly consists of agenesis or hypoplasia of the vestibulocochlear nerve. Tumoral pathology affecting the vestibulocochlear nerve is most frequently located in the internal auditory canal or cerebellopontine angle. Schwannoma of the vestibulocochlear nerve is the most frequently found tumoral lesion followed by meningeoma, arachnoid cyst and epidermoid cyst. The most frequently encountered pathologies as well as some more rare entities are discussed in this chapter.

  16. Pathology of the vestibulocochlear nerve

    International Nuclear Information System (INIS)

    De Foer, Bert; Kenis, Christoph; Van Melkebeke, Deborah; Vercruysse, Jean-Philippe; Somers, Thomas; Pouillon, Marc; Offeciers, Erwin; Casselman, Jan W.

    2010-01-01

    There is a large scala of pathology affecting the vestibulocochlear nerve. Magnetic resonance imaging is the method of choice for the investigation of pathology of the vestibulocochlear nerve. Congenital pathology mainly consists of agenesis or hypoplasia of the vestibulocochlear nerve. Tumoral pathology affecting the vestibulocochlear nerve is most frequently located in the internal auditory canal or cerebellopontine angle. Schwannoma of the vestibulocochlear nerve is the most frequently found tumoral lesion followed by meningeoma, arachnoid cyst and epidermoid cyst. The most frequently encountered pathologies as well as some more rare entities are discussed in this chapter.

  17. Neural-differentiated mesenchymal stem cells incorporated into muscle stuffed vein scaffold forms a stable living nerve conduit.

    Science.gov (United States)

    Hassan, Nur Hidayah; Sulong, Ahmad Fadzli; Ng, Min-Hwei; Htwe, Ohnmar; Idrus, Ruszymah B H; Roohi, Sharifah; Naicker, Amaramalar S; Abdullah, Shalimar

    2012-10-01

    Autologous nerve grafts to bridge nerve gaps have donor site morbidity and possible neuroma formation resulting in development of various methods of bridging nerve gaps without using autologous nerve grafts. We have fabricated an acellular muscle stuffed vein seeded with differentiated mesenchymal stem cells (MSCs) as a substitute for nerve autografts. Human vein and muscle were both decellularized by liquid nitrogen immersion with subsequent hydrolysis in hydrochloric acid. Human MSCs were subjected to a series of treatments with a reducing agent, retinoic acid, and a combination of trophic factors. The differentiated MSCs were seeded on the surface of acellular muscle tissue and then stuffed into the vein. Our study showed that 35-75% of the cells expressed neural markers such as S100b, glial fibrillary acidic protein (GFAP), p75 NGF receptor, and Nestin after differentiation. Histological and ultra structural analyses of muscle stuffed veins showed attachment of cells onto the surface of the acellular muscle and penetration of the cells into the hydrolyzed fraction of muscle fibers. We implanted these muscle stuffed veins into athymic mice and at 8 weeks post-implantation, the acellular muscle tissue had fully degraded and replaced with new matrix produced by the seeded cells. The vein was still intact and no inflammatory reactions were observed proving the biocompatibility and biodegradability of the conduit. In conclusion, we have successfully formed a stable living nerve conduit which may serve as a substitute for autologous nerves. Copyright © 2012 Orthopaedic Research Society.

  18. Polarization-engineered GaN/InGaN/GaN tunnel diodes

    International Nuclear Information System (INIS)

    Krishnamoorthy, Sriram; Nath, Digbijoy N.; Akyol, Fatih; Park, Pil Sung; Esposto, Michele; Rajan, Siddharth

    2010-01-01

    We report on the design and demonstration of polarization-engineered GaN/InGaN/GaN tunnel junction diodes with high current density and low tunneling turn-on voltage. Wentzel-Kramers-Brillouin calculations were used to model and design tunnel junctions with narrow band gap InGaN-based barrier layers. N-polar p-GaN/In 0.33 Ga 0.67 N/n-GaN heterostructure tunnel diodes were grown using molecular beam epitaxy. Efficient interband tunneling was achieved close to zero bias with a high current density of 118 A/cm 2 at a reverse bias of 1 V, reaching a maximum current density up to 9.2 kA/cm 2 . These results represent the highest current density reported in III-nitride tunnel junctions and demonstrate the potential of III-nitride tunnel devices for a broad range of optoelectronic and electronic applications.

  19. Radiation-induced cranial nerve palsy

    International Nuclear Information System (INIS)

    Berger, P.S.; Bataini, J.P.

    1977-01-01

    Twenty-five patients with 35 cranial nerve palsies were seen at the Fondation Curie during follow-up after radical radiotherapy for head and neck tumors. The twelfth nerve was involved in 19 cases, the tenth in nine, and the eleventh in five; the fifth and second nerves were involved once each and in the same patient. The twelfth nerve was involved alone in 16 patients and the tenth nerve alone in three, with multiple nerves involved in the remaining six patients. The palsy was noted from 12 to 145 months after diagnosis of the tumor. The latency period could be correlated with dose so that the least square fit equation representing NSD vs delay is NSD = 2598--Delay (in months) x 4.6, with a correlation coefficient of -0.58. The distinction between tumor recurrence and radiation-induced nerve palsy is critical. It can often be inferred from the latency period but must be confirmed by observation over a period of time

  20. Mass Spectrometry to Identify New Biomarkers of Nerve Agent Exposure

    Science.gov (United States)

    2010-04-01

    preparations. Improving thermal stability by mutagene- sis or by selecting enzyme candidates in an extremophile biotope, e.g. thermophilic bacteria [36...target for oganophosphorus agent (OP) binding to enzymes is the active site serine in the consensus sequence GlyXSerXGly of acetylcholinesterase. By...human plasma. Task 6. Use a second method, for example enzyme activity assays or immunoprecipitation, to confirm the identity of soman-labeled proteins

  1. Automated synthesis, characterization and biological evaluation of [{sup 68}Ga]Ga-AMBA, and the synthesis and characterization of {sup nat}Ga-AMBA and [{sup 67}Ga]Ga-AMBA

    Energy Technology Data Exchange (ETDEWEB)

    Cagnolini, Aldo; Chen Jianqing; Ramos, Kimberly; Marie Skedzielewski, Tina; Lantry, Laura E.; Nunn, Adrian D.; Swenson, Rolf E. [Ernst Felder Laboratories, Bracco Research USA Inc., 305 College Road East, Princeton, NJ 08540 (United States); Linder, Karen E., E-mail: karen.e.linder@gmail.co [Ernst Felder Laboratories, Bracco Research USA Inc., 305 College Road East, Princeton, NJ 08540 (United States)

    2010-12-15

    Ga-AMBA (Ga-DO3A-CH{sub 2}CO-G-[4-aminobenzoyl]-QWAVGHLM-NH{sub 2}) is a bombesin-like agonist with high affinity for gastrin releasing peptide receptors (GRP-R). Syntheses for {sup nat}Ga-AMBA, [{sup 67}Ga]Ga-AMBA and [{sup 68}Ga]Ga-AMBA were developed. The preparation of HPLC-purified and Sep-Pak purified [{sup 68}Ga]Ga-AMBA were fully automated, using the built-in radiodetector of the Tracerlab FX F-N synthesizer to monitor fractionated {sup 68}Ge/{sup 68}Ga generator elution and purification. The total synthesis time, including the fractional elution of the generator, was 20 min for Sep-Pak purified material and 40 min for HPLC-purified [{sup 68}Ga]Ga-AMBA. Both [{sup 67}Ga]Ga-AMBA and [{sup 177}Lu]Lu-AMBA showed comparable high affinity for GRP-R in the human prostate cancer cell line PC-3 in vitro (k{sub D}=0.46{+-}0.07; 0.44{+-}0.08 nM), high internalization (78; 77%) and low efflux from cells at 2 h (2.4{+-}0.7; 2.9{+-}1.8%). Biodistribution results in PC-3 tumor-bearing male nude mice showed comparable uptake for [{sup 177}Lu]Lu-, [{sup 111}In]In-, [{sup 67}Ga]Ga- and [{sup 68}Ga]Ga-AMBA.

  2. Strain Balanced AlGaN/GaN/AlGaN nanomembrane HEMTs.

    Science.gov (United States)

    Chang, Tzu-Hsuan; Xiong, Kanglin; Park, Sung Hyun; Yuan, Ge; Ma, Zhenqiang; Han, Jung

    2017-07-25

    Single crystal semiconductor nanomembranes (NM) are important in various applications such as heterogeneous integration and flexible devices. This paper reports the fabrication of AlGaN/GaN NMs and NM high electron mobility transistors (HEMT). Electrochemical etching is used to slice off single-crystalline AlGaN/GaN layers while preserving their microstructural quality. A double heterostructure design with a symmetric strain profile is employed to ensure minimal residual strain in freestanding NMs after release. The mobility of the two-dimensional electron gas (2DEG), formed by the AlGaN/GaN heterostructure, is noticeably superior to previously reported values of many other NMs. AlGaN/GaN nanomembrane HEMTs are fabricated on SiO 2 and flexible polymeric substrates. Excellent electrical characteristics, including a high ON/OFF ratio and transconductance, suggest that III-Nitrides nanomembranes are capable of supporting high performance applications.

  3. Early detection of interstitial pneumonia by 67Ga-citrate scintigraphy

    International Nuclear Information System (INIS)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada

    1985-01-01

    In this paper we report our recent experience indicating usefulness of 67 Ga-citrate scintigraphy in 4 cases with inflammatory pulmonary diseases. These cases showed abnormal pulmonary 67 Ga uptake with normal chest radiographs. The first case with malignant lymphoma and the second one with lung cancer suffered from pulmonary infection following secondary immuno-insufficiency due to radiotherapy and chemotherapy. Pneumocystis carinii was suspected as causative agent in the first case, and gram negative bacilli in the second case. The third case with lung cancer developed radiation pneumonia after radiotherapy. The fourth case with acute bronchitis developed drug induced interstitial pneumonia presumably due to minocycline administration. It is concluded that 67 Ga-citrate scintigraphy is more sensitive for early detection of interstitial pneumonia than routine chest radiography. (author)

  4. Matching of motor-sensory modality in the rodent femoral nerve model shows no enhanced effect on peripheral nerve regeneration

    Science.gov (United States)

    Kawamura, David H.; Johnson, Philip J.; Moore, Amy M.; Magill, Christina K.; Hunter, Daniel A.; Ray, Wilson Z.; Tung, Thomas HH.; Mackinnon, Susan E.

    2010-01-01

    The treatment of peripheral nerve injuries with nerve gaps largely consists of autologous nerve grafting utilizing sensory nerve donors. Underlying this clinical practice is the assumption that sensory autografts provide a suitable substrate for motoneuron regeneration, thereby facilitating motor endplate reinnervation and functional recovery. This study examined the role of nerve graft modality on axonal regeneration, comparing motor nerve regeneration through motor, sensory, and mixed nerve isografts in the Lewis rat. A total of 100 rats underwent grafting of the motor or sensory branch of the femoral nerve with histomorphometric analysis performed after 5, 6, or 7 weeks. Analysis demonstrated similar nerve regeneration in motor, sensory, and mixed nerve grafts at all three time points. These data indicate that matching of motor-sensory modality in the rat femoral nerve does not confer improved axonal regeneration through nerve isografts. PMID:20122927

  5. Nerve stimulator-guided sciatic-femoral nerve block in raptors undergoing surgical treatment of pododermatitis.

    Science.gov (United States)

    d'Ovidio, Dario; Noviello, Emilio; Adami, Chiara

    2015-07-01

    To describe the nerve stimulator-guided sciatic-femoral nerve block in raptors undergoing surgical treatment of pododermatitis. Prospective clinical trial. Five captive raptors (Falco peregrinus) aged 6.7 ± 1.3 years. Anaesthesia was induced and maintained with isoflurane in oxygen. The sciatic-femoral nerve block was performed with 2% lidocaine (0.05 mL kg(-1) per nerve) as the sole intra-operative analgesic treatment. Intraoperative physiological variables were recorded every 10 minutes from endotracheal intubation until the end of anaesthesia. Assessment of intraoperative nociception was based on changes in physiological variables above baseline values, while evaluation of postoperative pain relied on species-specific behavioural indicators. The sciatic-femoral nerve block was feasible in raptors and the motor responses following electrical stimulation of both nerves were consistent with those reported in mammalian species. During surgery no rescue analgesia was required. The anaesthesia plane was stable and cardiorespiratory variables did not increase significantly in response to surgical stimulation. Iatrogenic complications, namely nerve damage and local anaesthetic toxicity, did not occur. Recovery was smooth and uneventful. The duration (mean ± SD) of the analgesic effect provided by the nerve block was 130 ± 20 minutes. The sciatic-femoral nerve block as described in dogs and rabbits can be performed in raptors as well. Further clinical trials with a control groups are required to better investigate the analgesic efficacy and the safety of this technique in raptors. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  6. The success rate of bupivacaine and lidocaine as anesthetic agents in inferior alveolar nerve block in teeth with irreversible pulpitis without spontaneous pain

    Directory of Open Access Journals (Sweden)

    Masoud Parirokh

    2015-05-01

    Full Text Available Objectives Achieving adequate anesthesia with inferior alveolar nerve blocks (IANB is of great importance during dental procedures. The aim of the present study was to assess the success rate of two anesthetic agents (bupivacaine and lidocaine for IANB when treating teeth with irreversible pulpitis. Materials and Methods Sixty volunteer male and female patients who required root canal treatment of a mandibular molar due to caries participated in the present study. The inclusion criteria included prolonged pain to thermal stimulus but no spontaneous pain. The patients were randomly allocated to receive either 2% lidocaine with 1:80,000 epinephrine or 0.5% bupivacaine with 1:200,000 epinephrine as an IANB injection. The sensitivity of the teeth to a cold test as well as the amount of pain during access cavity preparation and root canal instrumentation were recorded. Results were statistically analyzed with the Chi-Square and Fischer's exact tests. Results At the final step, fifty-nine patients were included in the study. The success rate for bupivacaine and lidocaine groups were 20.0% and 24.1%, respectively. There was no significant difference between the two groups at any stage of the treatment procedure. Conclusions There was no difference in success rates of anesthesia when bupivacaine and lidocaine were used for IANB injections to treat mandibular molar teeth with irreversible pulpitis. Neither agent was able to completely anesthetize the teeth effectively. Therefore, practitioners should be prepared to administer supplemental anesthesia to overcome pain during root canal treatment.

  7. The success rate of bupivacaine and lidocaine as anesthetic agents in inferior alveolar nerve block in teeth with irreversible pulpitis without spontaneous pain

    Science.gov (United States)

    Yosefi, Mohammad Hosein; Nakhaee, Nouzar

    2015-01-01

    Objectives Achieving adequate anesthesia with inferior alveolar nerve blocks (IANB) is of great importance during dental procedures. The aim of the present study was to assess the success rate of two anesthetic agents (bupivacaine and lidocaine) for IANB when treating teeth with irreversible pulpitis. Materials and Methods Sixty volunteer male and female patients who required root canal treatment of a mandibular molar due to caries participated in the present study. The inclusion criteria included prolonged pain to thermal stimulus but no spontaneous pain. The patients were randomly allocated to receive either 2% lidocaine with 1:80,000 epinephrine or 0.5% bupivacaine with 1:200,000 epinephrine as an IANB injection. The sensitivity of the teeth to a cold test as well as the amount of pain during access cavity preparation and root canal instrumentation were recorded. Results were statistically analyzed with the Chi-Square and Fischer's exact tests. Results At the final step, fifty-nine patients were included in the study. The success rate for bupivacaine and lidocaine groups were 20.0% and 24.1%, respectively. There was no significant difference between the two groups at any stage of the treatment procedure. Conclusions There was no difference in success rates of anesthesia when bupivacaine and lidocaine were used for IANB injections to treat mandibular molar teeth with irreversible pulpitis. Neither agent was able to completely anesthetize the teeth effectively. Therefore, practitioners should be prepared to administer supplemental anesthesia to overcome pain during root canal treatment. PMID:25984478

  8. Evaluation of phrenic nerve and diaphragm function with peripheral nerve stimulation and M-mode ultrasonography in potential pediatric phrenic nerve or diaphragm pacing candidates.

    Science.gov (United States)

    Skalsky, Andrew J; Lesser, Daniel J; McDonald, Craig M

    2015-02-01

    Assessing phrenic nerve function in the setting of diaphragmatic paralysis in diaphragm pacing candidates can be challenging. Traditional imaging modalities and electrodiagnostic evaluations are technically difficult. Either modality alone is not a direct measure of the function of the phrenic nerve and diaphragm unit. In this article, the authors present their method for evaluating phrenic nerve function and the resulting diaphragm function. Stimulating the phrenic nerve with transcutaneous stimulation and directly observing the resulting movement of the hemidiaphragm with M-mode ultrasonography provides quantitative data for predicting the success of advancing technologies such as phrenic nerve pacing and diaphragm pacing. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Performance Analysis of GaN Capping Layer Thickness on GaN/AlGaN/GaN High Electron Mobility Transistors.

    Science.gov (United States)

    Sharma, N; Periasamy, C; Chaturvedi, N

    2018-07-01

    In this paper, we present an investigation of the impact of GaN capping layer and AlGaN layer thickness on the two-dimensional (2D)-electron mobility and the carrier concentration which was formed close to the AlGaN/GaN buffer layer for Al0.25Ga0.75N/GaN and GaN/Al0.25Ga0.75N/GaN heterostructures deposited on sapphire substrates. The results of our analysis clearly indicate that expanding the GaN capping layer thickness from 1 nm to 100 nm prompts an increment in the electron concentration at hetero interface. As consequence of which drain current was additionally increments with GaN cap layer thicknesses, and eventually saturates at approximately 1.85 A/mm for capping layer thickness greater than 40 nm. Interestingly, for the same structure, the 2D-electron mobility, decrease monotonically with GaN capping layer thickness, and saturate at approximately 830 cm2/Vs for capping layer thickness greater than 50 nm. A device with a GaN cap layer didn't exhibit gate leakage current. Furthermore, it was observed that the carrier concentration was first decrease 1.03 × 1019/cm3 to 6.65 × 1018/cm3 with AlGaN Layer thickness from 5 to 10 nm and after that it increases with the AlGaN layer thickness from 10 to 30 nm. The same trend was followed for electric field distributions. Electron mobility decreases monotonically with AlGaN layer thickness. Highest electron mobility 1354 cm2/Vs were recorded for the AlGaN layer thickness of 5 nm. Results obtained are in good agreement with published experimental data.

  10. Atomic-scale structure of irradiated GaN compared to amorphised GaP and GaAs

    International Nuclear Information System (INIS)

    Ridgway, M.C.; Everett, S.E.; Glover, C.J.; Kluth, S.M.; Kluth, P.; Johannessen, B.; Hussain, Z.S.; Llewellyn, D.J.; Foran, G.J.; Azevedo, G. de M.

    2006-01-01

    We have compared the atomic-scale structure of ion irradiated GaN to that of amorphised GaP and GaAs. While continuous and homogenous amorphised layers were easily achieved in GaP and GaAs, ion irradiation of GaN yielded both structural and chemical inhomogeneities. Transmission electron microscopy revealed GaN crystallites and N 2 bubbles were interspersed within an amorphous GaN matrix. The crystallite orientation was random relative to the unirradiated epitaxial structure, suggesting their formation was irradiation-induced, while the crystallite fraction was approximately constant for all ion fluences beyond the amorphisation threshold, consistent with a balance between amorphisation and recrystallisation processes. Extended X-ray absorption fine structure measurements at the Ga K-edge showed short-range order was retained in the amorphous phase for all three binary compounds. For ion irradiated GaN, the stoichiometric imbalance due to N 2 bubble formation was not accommodated by Ga-Ga bonding in the amorphous phase or precipitation of metallic Ga but instead by a greater reduction in Ga coordination number

  11. Trends in the design of nerve guidance channels in peripheral nerve tissue engineering.

    Science.gov (United States)

    Chiono, Valeria; Tonda-Turo, Chiara

    2015-08-01

    The current trend of peripheral nerve tissue engineering is the design of advanced nerve guidance channels (NGCs) acting as physical guidance for regeneration of nerves across lesions. NGCs should present multifunctional properties aiming to direct the sprouting of axons from the proximal nerve end, to concentrate growth factors secreted by the injured nerve ends, and to reduce the ingrowth of scar tissue into the injury site. A critical aspect in the design of NGCs is conferring them the ability to provide topographic, chemotactic and haptotactic cues that lead to functional nerve regeneration thus increasing the axon growth rate and avoiding or minimizing end-organ (e.g. muscle) atrophy. The present work reviews the recent state of the art in NGCs engineering and defines the external guide and internal fillers structural and compositional requirements that should be satisfied to improve nerve regeneration, especially in the case of large gaps (>2 cm). Techniques for NGCs fabrication were described highlighting the innovative approaches direct to enhance the regeneration of axon stumps compared to current clinical treatments. Furthermore, the possibility to apply stem cells as internal cues to the NGCs was discussed focusing on scaffold properties necessary to ensure cell survival. Finally, the optimized features for NGCs design were summarized showing as multifunctional cues are needed to produce NGCs having improved results in clinics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Facilitation of facial nerve regeneration using chitosan-β-glycerophosphate-nerve growth factor hydrogel.

    Science.gov (United States)

    Chao, Xiuhua; Xu, Lei; Li, Jianfeng; Han, Yuechen; Li, Xiaofei; Mao, YanYan; Shang, Haiqiong; Fan, Zhaomin; Wang, Haibo

    2016-06-01

    Conclusion C/GP hydrogel was demonstrated to be an ideal drug delivery vehicle and scaffold in the vein conduit. Combined use autologous vein and NGF continuously delivered by C/GP-NGF hydrogel can improve the recovery of facial nerve defects. Objective This study investigated the effects of chitosan-β-glycerophosphate-nerve growth factor (C/GP-NGF) hydrogel combined with autologous vein conduit on the recovery of damaged facial nerve in a rat model. Methods A 5 mm gap in the buccal branch of a rat facial nerve was reconstructed with an autologous vein. Next, C/GP-NGF hydrogel was injected into the vein conduit. In negative control groups, NGF solution or phosphate-buffered saline (PBS) was injected into the vein conduits, respectively. Autologous implantation was used as a positive control group. Vibrissae movement, electrophysiological assessment, and morphological analysis of regenerated nerves were performed to assess nerve regeneration. Results NGF continuously released from C/GP-NGF hydrogel in vitro. The recovery rate of vibrissae movement and the compound muscle action potentials of regenerated facial nerve in the C/GP-NGF group were similar to those in the Auto group, and significantly better than those in the NGF group. Furthermore, larger regenerated axons and thicker myelin sheaths were obtained in the C/GP-NGF group than those in the NGF group.

  13. Effect of hip and knee position on nerve conduction in the common fibular nerve.

    Science.gov (United States)

    Broadhurst, Peter Kaas; Robinson, Lawrence R

    2017-09-01

    The aim of this study was to measure the influence that hip and knee position have on routine fibular motor nerve conduction studies. Healthy subjects under age 40 were recruited (n = 24) to have fibular nerve conduction studies completed in various positions, using hip extension-knee extension as a control. A mean increase in conduction velocity of 2.5 m/s across the knee (P = 0.020) was seen during hip flexion compared with hip extension. A mean decrease in velocity of 1.6 m/s through the leg segment (P = 0.016) was seen during knee flexion compared with knee extension. This study shows that the optimal position of the leg during fibular nerve studies is with the hip in flexion and knee in extension, to more accurately reflect nerve length for velocity calculations. This may have implications for other peripheral nerves with respect to proximal joint position affecting calculated velocity. Muscle Nerve 56: 519-521, 2017. © 2017 Wiley Periodicals, Inc.

  14. [The VR, the Russian version of the nerve agent VX].

    Science.gov (United States)

    Cuquel, A-C; Dorandeu, F; Ceppa, F; Renard, C; Burnat, P

    2015-05-01

    A product of the arms race during the Cold War, the Russian VX, or VR, is an organophosphorus compound that is a structural isomer of the western VX compound (or A4), with which it shares a very high toxicity. It is much less studied and known than VX because the knowledge of its existence is relatively recent. A very low volatility and high resistance in the environment make it a persistent agent. Poisoning occurs mainly following penetration through skin and mucosa but vapour inhalation is a credible risk in some circumstances. The clinical presentation may be differed by several hours and despite the absence of signs and symptoms, the casualty should not be considered as contamination or intoxication-free. This agent has a long residence time in blood, a characteristics that clearly differentiates it from other compounds such as sarin. The protocols for antidote administration may thus have to be changed accordingly. The fact that VR poisoned individuals will less respond to the current oxime therapy used in France, the 2-PAM and that VR represents a higher threat than VX, being probably possessed by some proliferating states, justify the interest for this toxic product. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  15. Microsurgical anatomy of the abducens nerve.

    Science.gov (United States)

    Joo, Wonil; Yoshioka, Fumitaka; Funaki, Takeshi; Rhoton, Albert L

    2012-11-01

    The aim of this study is to demonstrate and review the detailed microsurgical anatomy of the abducens nerve and surrounding structures along its entire course and to provide its topographic measurements. Ten cadaveric heads were examined using ×3 to ×40 magnification after the arteries and veins were injected with colored silicone. Both sides of each cadaveric head were dissected using different skull base approaches to demonstrate the entire course of the abducens nerve from the pontomedullary sulcus to the lateral rectus muscle. The anatomy of the petroclival area and the cavernous sinus through which the abducens nerve passes are complex due to the high density of critically important neural and vascular structures. The abducens nerve has angulations and fixation points along its course that put the nerve at risk in many clinical situations. From a surgical viewpoint, the petrous tubercle of the petrous apex is an intraoperative landmark to avoid damage to the abducens nerve. The abducens nerve is quite different from the other nerves. No other cranial nerve has a long intradural path with angulations and fixations such as the abducens nerve in petroclival venous confluence. A precise knowledge of the relationship between the abducens nerve and surrounding structures has allowed neurosurgeon to approach the clivus, petroclival area, cavernous sinus, and superior orbital fissure without surgical complications. Copyright © 2012 Wiley Periodicals, Inc.

  16. Biocompatibility of Different Nerve Tubes

    Science.gov (United States)

    Stang, Felix; Keilhoff, Gerburg; Fansa, Hisham

    2009-01-01

    Bridging nerve gaps with suitable grafts is a major clinical problem. The autologous nerve graft is considered to be the gold standard, providing the best functional results; however, donor site morbidity is still a major disadvantage. Various attempts have been made to overcome the problems of autologous nerve grafts with artificial nerve tubes, which are “ready-to-use” in almost every situation. A wide range of materials have been used in animal models but only few have been applied to date clinically, where biocompatibility is an inevitable prerequisite. This review gives an idea about artificial nerve tubes with special focus on their biocompatibility in animals and humans.

  17. Axillary nerve dysfunction

    Science.gov (United States)

    ... changes in sensation or movement No history of injury to the area No signs of nerve damage These medicines reduce swelling and pressure on the nerve. They may be injected directly into the area or taken by mouth. Other medicines include: Over-the-counter pain ...

  18. Peripheral nerve hyperexcitability with preterminal nerve and neuromuscular junction remodeling is a hallmark of Schwartz-Jampel syndrome.

    Science.gov (United States)

    Bauché, Stéphanie; Boerio, Delphine; Davoine, Claire-Sophie; Bernard, Véronique; Stum, Morgane; Bureau, Cécile; Fardeau, Michel; Romero, Norma Beatriz; Fontaine, Bertrand; Koenig, Jeanine; Hantaï, Daniel; Gueguen, Antoine; Fournier, Emmanuel; Eymard, Bruno; Nicole, Sophie

    2013-12-01

    Schwartz-Jampel syndrome (SJS) is a recessive disorder with muscle hyperactivity that results from hypomorphic mutations in the perlecan gene, a basement membrane proteoglycan. Analyses done on a mouse model have suggested that SJS is a congenital form of distal peripheral nerve hyperexcitability resulting from synaptic acetylcholinesterase deficiency, nerve terminal instability with preterminal amyelination, and subtle peripheral nerve changes. We investigated one adult patient with SJS to study this statement in humans. Perlecan deficiency due to hypomorphic mutations was observed in the patient biological samples. Electroneuromyography showed normal nerve conduction, neuromuscular transmission, and compound nerve action potentials while multiple measures of peripheral nerve excitability along the nerve trunk did not detect changes. Needle electromyography detected complex repetitive discharges without any evidence for neuromuscular transmission failure. The study of muscle biopsies containing neuromuscular junctions showed well-formed post-synaptic element, synaptic acetylcholinesterase deficiency, denervation of synaptic gutters with reinnervation by terminal sprouting, and long nonmyelinated preterminal nerve segments. These data support the notion of peripheral nerve hyperexcitability in SJS, which would originate distally from synergistic actions of peripheral nerve and neuromuscular junction changes as a result of perlecan deficiency. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Nerve stepping stone has minimal impact in aiding regeneration across long acellular nerve allografts.

    Science.gov (United States)

    Yan, Ying; Hunter, Daniel A; Schellhardt, Lauren; Ee, Xueping; Snyder-Warwick, Alison K; Moore, Amy M; Mackinnon, Susan E; Wood, Matthew D

    2018-02-01

    Acellular nerve allografts (ANAs) yield less consistent favorable outcomes compared with autografts for long gap reconstructions. We evaluated whether a hybrid ANA can improve 6-cm gap reconstruction. Rat sciatic nerve was transected and repaired with either 6-cm hybrid or control ANAs. Hybrid ANAs were generated using a 1-cm cellular isograft between 2.5-cm ANAs, whereas control ANAs had no isograft. Outcomes were assessed by graft gene and marker expression (n = 4; at 4 weeks) and motor recovery and nerve histology (n = 10; at 20 weeks). Hybrid ANAs modified graft gene and marker expression and promoted modest axon regeneration across the 6-cm defect compared with control ANA (P nerve gaps with autografts. Muscle Nerve 57: 260-267, 2018. © 2017 Wiley Periodicals, Inc.

  20. Treatment of soft-tissue loss with nerve defect in the finger using the boomerang nerve flap.

    Science.gov (United States)

    Chen, Chao; Tang, Peifu; Zhang, Xu

    2013-01-01

    This study reports simultaneous repair of soft-tissue loss and proper digital nerve defect in the finger using a boomerang nerve flap including nerve graft from the dorsal branch of the proper digital nerve. From July of 2007 to May of 2010, the flap was used in 17 fingers in 17 patients. The injured fingers included five index, seven long, and five ring fingers. The mean soft-tissue loss was 2.5 × 1.9 cm. The mean flap size was 2.8 × 2.1 cm. Proper digital nerve defects were reconstructed using nerve graft harvested from the dorsal branch of the adjacent finger's proper digital nerve. The average nerve graft length was 2.5 cm. The comparison group included 32 patients treated using a cross-finger flap and a secondary free nerve graft. In the study group, 15 flaps survived completely. Partial necrosis at the distal edge of the flap occurred in two cases. At a mean follow-up of 22 months, the average static two-point discrimination and Semmes-Weinstein monofilament test results on the pulp of the reconstructed finger were 7.5 mm and 3.86, respectively. In the comparison group, the results were 9.3 mm and 3.91, respectively. The study group presented better discriminatory sensation on the pulp and milder pain and cold intolerance in the reconstructed finger. The boomerang nerve flap is useful and reliable for reconstructing complicated finger damage involving soft-tissue loss and nerve defect, especially in difficult anatomical regions. Therapeutic, II.

  1. Neuroprotective effect of lurasidone via antagonist activities on histamine in a rat model of cranial nerve involvement.

    Science.gov (United States)

    He, Baoming; Yu, Liang; Li, Suping; Xu, Fei; Yang, Lili; Ma, Shuai; Guo, Yi

    2018-04-01

    Cranial nerve involvement frequently involves neuron damage and often leads to psychiatric disorder caused by multiple inducements. Lurasidone is a novel antipsychotic agent approved for the treatment of cranial nerve involvement and a number of mental health conditions in several countries. In the present study, the neuroprotective effect of lurasidone by antagonist activities on histamine was investigated in a rat model of cranial nerve involvement. The antagonist activities of lurasidone on serotonin 5‑HT7, serotonin 5‑HT2A, serotonin 5‑HT1A and serotonin 5‑HT6 were analyzed, and the preclinical therapeutic effects of lurasidone were examined in a rat model of cranial nerve involvement. The safety, maximum tolerated dose (MTD) and preliminary antitumor activity of lurasidone were also assessed in the cranial nerve involvement model. The therapeutic dose of lurasidone was 0.32 mg once daily, administered continuously in 14‑day cycles. The results of the present study found that the preclinical prescriptions induced positive behavioral responses following treatment with lurasidone. The MTD was identified as a once daily administration of 0.32 mg lurasidone. Long‑term treatment with lurasidone for cranial nerve involvement was shown to improve the therapeutic effects and reduce anxiety in the experimental rats. In addition, treatment with lurasidone did not affect body weight. The expression of the language competence protein, Forkhead‑BOX P2, was increased, and the levels of neuroprotective SxIP motif and microtubule end‑binding protein were increased in the hippocampal cells of rats with cranial nerve involvement treated with lurasidone. Lurasidone therapy reinforced memory capability and decreased anxiety. Taken together, lurasidone treatment appeared to protect against language disturbances associated with negative and cognitive impairment in the rat model of cranial nerve involvement, providing a basis for its use in the clinical treatment of

  2. Future Perspectives in the Management of Nerve Injuries.

    Science.gov (United States)

    Mackinnon, Susan E

    2018-04-01

     The author presents a solicited "white paper" outlining her perspective on the role of nerve transfers in the management of nerve injuries.  PubMed/MEDLINE and EMBASE databases were evaluated to compare nerve graft and nerve transfer. An evaluation of the scientific literature by review of index articles was also performed to compare the number of overall clinical publications of nerve repair, nerve graft, and nerve transfer. Finally, a survey regarding the prevalence of nerve transfer surgery was administrated to the World Society of Reconstructive Microsurgery (WSRM) results.  Both nerve graft and transfer can generate functional results and the relative success of graft versus transfer depended on the function to be restored and the specific transfers used. Beginning in the early 1990s, there has been a rapid increase from baseline of nerve transfer publications such that clinical nerve transfer publication now exceeds those of nerve repair or nerve graft. Sixty-two responses were received from WSRM membership. These surgeons reported their frequency of "usually or always using nerve transfers for repairing brachial plexus injuries as 68%, radial nerves as 27%, median as 25%, and ulnar as 33%. They reported using nerve transfers" sometimes for brachial plexus 18%, radial nerve 30%, median nerve 34%, ulnar nerve 35%.  Taken together this evidence suggests that nerve transfers do offer an alternative technique along with tendon transfers, nerve repair, and nerve grafts. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Treating exposure to chemical warfare agents: implications for health care providers and community emergency planning.

    Science.gov (United States)

    Munro, N B; Watson, A P; Ambrose, K R; Griffin, G D

    1990-01-01

    Current treatment protocols for exposure to nerve and vesicant agents found in the U.S. stockpile of unitary chemical weapons are summarized, and the toxicities of available antidotes are evaluated. The status of the most promising of the new nerve agent antidotes is reviewed. In the U.S. atropine and pralidoxime compose the only approved antidote regimen for organophosphate nerve agent poisoning. Diazepam may also be used if necessary to control convulsions. To avoid death, administration must occur within minutes of substantial exposure together with immediate decontamination. Continuous observation and repeated administration of antidotes are necessary as symptoms warrant. Available antidotes do not necessarily prevent respiratory failure or incapacitation. The toxicity of the antidotes themselves and the individualized nature of medical care preclude recommending that autoinjectors be distributed to the general public. In addition, precautionary administration of protective drugs to the general population would not be feasible or desirable. No antidote exists for poisoning by the vesicant sulfur mustard (H, HD, HT); effective intervention can only be accomplished by rapid decontamination followed by palliative treatment of symptoms. British anti-Lewisite (BAL) (2,3-dimercapto-1-propanolol) is the antidote of choice for treatment of exposure to Lewisite, another potent vesicant. Experimental water-soluble BAL analogues have been developed that are less toxic than BAL. Treatment protocols for each antidote are summarized in tabular form for use by health care providers. PMID:2088748

  4. Radiolabeled enzyme inhibitors and binding agents targeting PSMA: Effective theranostic tools for imaging and therapy of prostate cancer

    International Nuclear Information System (INIS)

    Pillai, Maroor Raghavan Ambikalmajan; Nanabala, Raviteja; Joy, Ajith; Sasikumar, Arun; Knapp, Furn F.

    2016-01-01

    Because of the broad incidence, morbidity and mortality associated with prostate-derived cancer, the development of more effective new technologies continues to be an important goal for the accurate detection and treatment of localized prostate cancer, lymphatic involvement and metastases. Prostate-specific membrane antigen (PSMA; Glycoprotein II) is expressed in high levels on prostate-derived cells and is an important target for visualization and treatment of prostate cancer. Radiolabeled peptide targeting technologies have rapidly evolved over the last decade and have focused on the successful development of radiolabeled small molecules that act as inhibitors to the binding of the N-acetyl-L-aspartyl-L-glutamate (NAAG) substrate to the PSMA molecule. A number of radiolabeled PSMA inhibitors have been described in the literature and labeled with SPECT, PET and therapeutic radionuclides. Clinical studies with these agents have demonstrated the improved potential of PSMA-targeted PET imaging agents to detect metastatic prostate cancer in comparison with conventional imaging technologies. Although many of these agents have been evaluated in humans, by far the most extensive clinical literature has described use of the 68 Ga and 177 Lu agents. This review describes the design and development of these agents, with a focus on the broad clinical introduction of PSMA targeting motifs labeled with 68 Ga for PET-CT imaging and 177 Lu for therapy. In particular, because of availability from the long-lived 68 Ge (T 1/2 = 270 days)/ 68 Ga (T 1/2 = 68 min) generator system and increasing availability of PET-CT, the 68 Ga-labeled PSMA targeted agent is receiving widespread interest and is one of the fastest growing radiopharmaceuticals for PET-CT imaging.

  5. Normal and sonographic anatomy of selected peripheral nerves. Part II: Peripheral nerves of the upper limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is frequently used for imaging peripheral nerves. It serves to supplement the physical examination, electromyography, and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive, well-tolerated by patients, and relatively inexpensive. Part I of this article series described in detail the characteristic USG picture of peripheral nerves and the proper examination technique, following the example of the median nerve. This nerve is among the most often examined peripheral nerves of the upper limb. This part presents describes the normal anatomy and ultrasound picture of the remaining large nerve branches in the upper extremity and neck – the spinal accessory nerve, the brachial plexus, the suprascapular, axillary, musculocutaneous, radial and ulnar nerves. Their normal anatomy and ultrasonographic appearance have been described, including the division into individual branches. For each of them, specific reference points have been presented, to facilitate the location of the set trunk and its further monitoring. Sites for the application of the ultrasonographic probe at each reference point have been indicated. In the case of the ulnar nerve, the dynamic component of the examination was emphasized. The text is illustrated with images of probe positioning, diagrams of the normal course of the nerves as well as a series of ultrasonographic pictures of normal nerves of the upper limb. This article aims to serve as a guide in the ultrasound examination of the peripheral nerves of the upper extremity. It should be remembered that a thorough knowledge of the area’s topographic anatomy is required for this type of examination.

  6. Influência da irradiação do laser na regeneração nervosa em diferentes locais de tratamento Influence of laser radiation in nerve regeneration in different treatment sites

    Directory of Open Access Journals (Sweden)

    Fausto Fernandes de Almeida Sousa

    2009-01-01

    Full Text Available OBJETIVO: Verificar a influência do laser de baixa intensidade de AsGaAl na lesão por esmagamento do nervo peroneiro de ratos através da avaliação funcional da marcha nos diferentes locais de irradiação. MÉTODOS: Foram utilizados 53 ratos, divididos em seis grupos: normal, lesado não tratado, lesado e tratado placebo, lesado e tratado na medula, lesado e tratado no nervo, lesado e tratado em ambos (nervo e medula. O esmagamento do nervo peroneiro foi realizado por meio de uma pinça e subsequente tratado com laser por 28 dias consecutivos. Na avaliação funcional foram analisadas as impressões das pegadas, registradas pela câmera de vídeo em uma passarela de acrílico, no pré-operatório e aos 14º, 21º e 28º dias de pós-operatório, e avaliadas na fórmula PFI por meio do software. RESULTADOS: Na avaliação funcional da marcha foram encontradas diferenças significantes somente no 14º dia de pós-operatório. CONCLUSÃO: A irradiação do laser AsGaAl de baixa intensidade foi capaz de acelerar e potencializar o processo de regeneração nervosa periférica de ratos no 14º dia de pós-operatório, de acordo com a avaliação funcional da marcha, tanto para o grupo tratado na medula quanto para o grupo tratado no nervo.OBJECTIVE: This study seeks to determine, through functional gait assessment in different irradiation sites, the influence of a low-intensity GaAsAl laser beam on an injury caused by crushing the peroneal nerve in rats. METHODS: 53 rats were used, which were divided into six groups: normal, injured and untreated, injured and treated using placebo, injured and treated in the bone marrow, injured and treated in the nerve, and injured and treated in both (nerve and bone marrow. The peroneal nerve was crushed using a pair of tweezers, and subsequently treated with laser for 28 consecutive days. The functional gait evaluation analyzed the footprints, which were recorded with a video camera on an acrylic bridge in the

  7. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Natural history of sensory nerve recovery after cutaneous nerve injury following foot and ankle surgery

    Directory of Open Access Journals (Sweden)

    Lu Bai

    2015-01-01

    Full Text Available Cutaneous nerve injury is the most common complication following foot and ankle surgery. However, clinical studies including long-term follow-up data after cutaneous nerve injury of the foot and ankle are lacking. In the current retrospective study, we analyzed the clinical data of 279 patients who underwent foot and ankle surgery. Subjects who suffered from apparent paresthesia in the cutaneous sensory nerve area after surgery were included in the study. Patients received oral vitamin B 12 and methylcobalamin. We examined final follow-up data of 17 patients, including seven with sural nerve injury, five with superficial peroneal nerve injury, and five with plantar medial cutaneous nerve injury. We assessed nerve sensory function using the Medical Research Council Scale. Follow-up immediately, at 6 weeks, 3, 6 and 9 months, and 1 year after surgery demonstrated that sensory function was gradually restored in most patients within 6 months. However, recovery was slow at 9 months. There was no significant difference in sensory function between 9 months and 1 year after surgery. Painful neuromas occurred in four patients at 9 months to 1 year. The results demonstrated that the recovery of sensory function in patients with various cutaneous nerve injuries after foot and ankle surgery required at least 6 months

  9. Peripheral nerve involvement in Bell's palsy

    Directory of Open Access Journals (Sweden)

    J. A. Bueri

    1984-12-01

    Full Text Available A group of patients with Bell's palsy were studied in order to disclose the presence of subclinical peripheral nerve involvement. 20 patients, 8 male and 12 female, with recent Bell's palsy as their unique disease were examined, in all cases other causes of polyneuropathy were ruled out. Patients were investigated with CSF examination, facial nerve latencies in the affected and in the sound sides, and maximal motor nerve conduction velocities, as well as motor terminal latencies from the right median and peroneal nerves. CSF laboratory examination was normal in all cases. Facial nerve latencies were abnormal in all patients in the affected side, and they differed significantly from those of control group in the clinically sound side. Half of the patients showed abnormal values in the maximal motor nerve conduction velocities and motor terminal latencies of the right median and peroneal nerves. These results agree with previous reports which have pointed out that other cranial nerves may be affected in Bell's palsy. However, we have found a higher frequency of peripheral nerve involvement in this entity. These findings, support the hypothesis that in some patients Bell's palsy is the component of a more widespread disease, affecting other cranial and peripheral nerves.

  10. MRI of enlarged dorsal ganglia, lumbar nerve roots, and cranial nerves in polyradiculoneuropathies

    International Nuclear Information System (INIS)

    Castillo, M.; Mukherji, S.K.

    1996-01-01

    This paper describes the MRI findings in four patients with a clinical diagnosis of hypertrophic polyradiculoneuropathies. In two examination of the lumbar spine showed enlarged nerve roots and dorsal ganglia, and similar findings were present in the cervical spine in a third. The cisternal portions of the cranial nerves were enlarged in another patient. MRI allows identification of enlarged nerves in hypertrophic polyradiculopathies. (orig.)

  11. Tibial nerve (image)

    Science.gov (United States)

    ... nerve is commonly injured by fractures or other injury to the back of the knee or the lower leg. It may be affected by systemic diseases such as diabetes mellitus. The nerve can also be damaged by pressure from a tumor, abscess, or bleeding into the ...

  12. [Effects of nootropic agents on visual functions and lacrimal antioxidative activity in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Davydova, N G; Kuznetsova, T P; Borisova, S A; Abdulkadyrova, M Zh

    2006-01-01

    The paper presents the results of an investigation of the effect of the nootropic agents pantogam and nooclerine on visual functions in patients with primary open-angle glaucoma. These agents have been found to have a beneficial effect on the functional activity of the retina and optic nerve, light sensitivity, hemo- and hydrodynamics of the eye.

  13. Imaging the ocular motor nerves.

    NARCIS (Netherlands)

    Ferreira, T.; Verbist, B.M.; Buchem, M. van; Osch, T. van; Webb, A.

    2010-01-01

    The ocular motor nerves (OMNs) comprise the oculomotor, trochlear and the abducens nerves. According to their course, they are divided into four or five anatomic segments: intra-axial, cisternal, cavernous and intra-orbital and, for the abducens nerve, an additional interdural segment. Magnetic

  14. Ga-66 labeled somatostatin analogue DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide as a potential agent for positron emission tomography imaging and receptor mediated internal radiotherapy of somatostatin receptor positive tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ugur, Oemer E-mail: ougur@hacettepe.edu.tr; Kothari, Paresh J.; Finn, Ronald D.; Zanzonico, Pat; Ruan, Shutian; Guenther, Ilonka; Maecke, Helmut R.; Larson, Steven M

    2002-02-01

    Radionuclide labeled somatostatin analogues selectively target somatostatin receptor (SSTR)-expressing tumors as a basis for diagnosis and treatment of these tumors. Recently, a DOTA-functionalized somatostatin analogue, DOTATOC (DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide) has been developed. This compound has been shown to be superior to the other somatostatin analogues as indicated by its uniquely high tumor-to-non-target tissue ratio. DOTATOC can be labeled with a variety of radiometals including gallium radioisotopes. Gallium-66 is a positron emitting radionuclide (T{sub 1/2} =9.5 hr; {beta}{sup +}=56%), that can be produced in carrier free form by a low-beam energy cyclotron. In this study we investigated SSTR targeting characteristics of {sup 66}Ga-DOTATOC in AR42J rat pancreas tumor implanted nude mice as a potential agent for diagnosis and receptor-mediated internal radiotherapy of SSTR-expressing tumors. We compared our results with {sup 67}Ga- and {sup 68}Ga- labeled DOTATOC. The radiolabeling procedure gave labeling yield ranged from 85-95% and radiochemical and chemical purity was >95%. In-vitro competitive binding curves and in-vivo competitive displacement studies with an excess of unlabeled peptide indicates that there is specific binding of the radioligand to SSTR. Animal biodistribution data and serial microPET{sup TM} images demonstrated rapid tumor uptake and rapid clearance from the blood and all tissues except kidney. Maximum % ID/g values for tumor were 10.0{+-}0.7, 13.2{+-}2.1 and 9.8{+-}1.5 for {sup 66}Ga-, {sup 67}Ga-, and {sup 68}Ga-DOTATOC, respectively. Calculated tumor, kidney and bone marrow doses for {sup 66}Ga-DOTATOC based on biodistribution data were 178, 109 and 1.2 cGy/MBq, respectively. We conclude that {sup 66}Ga labeled DOTATOC can be used for PET diagnosis and quantitative imaging-based dosimetry of SSTR positive tumors. {sup 66}Ga-DOTATOC may also be used in higher doses for ablation of these tumors. However, kidney is the

  15. Role of Demyelination Efficiency within Acellular Nerve Scaffolds during Nerve Regeneration across Peripheral Defects

    Directory of Open Access Journals (Sweden)

    Meiqin Cai

    2017-01-01

    Full Text Available Hudson’s optimized chemical processing method is the most commonly used chemical method to prepare acellular nerve scaffolds for the reconstruction of large peripheral nerve defects. However, residual myelin attached to the basal laminar tube has been observed in acellular nerve scaffolds prepared using Hudson’s method. Here, we describe a novel method of producing acellular nerve scaffolds that eliminates residual myelin more effectively than Hudson’s method through the use of various detergent combinations of sulfobetaine-10, sulfobetaine-16, Triton X-200, sodium deoxycholate, and peracetic acid. In addition, the efficacy of this new scaffold in repairing a 1.5 cm defect in the sciatic nerve of rats was examined. The modified method produced a higher degree of demyelination than Hudson’s method, resulting in a minor host immune response in vivo and providing an improved environment for nerve regeneration and, consequently, better functional recovery. A morphological study showed that the number of regenerated axons in the modified group and Hudson group did not differ. However, the autograft and modified groups were more similar in myelin sheath regeneration than the autograft and Hudson groups. These results suggest that the modified method for producing a demyelinated acellular scaffold may aid functional recovery in general after nerve defects.

  16. Spectroscopic ellipsometry analysis of InGaN/GaN and AlGaN/GaN heterostructures using a parametric dielectric function model

    International Nuclear Information System (INIS)

    Wagner, J.; Ramakrishnan, A.; Obloh, H.; Kunzer, M.; Koehler, K.; Johs, B.

    2000-01-01

    Spectroscopic ellipsometry (SE) has been used for the characterization of AlGaN/GaN and InGaN/GaN heterostructures. The resulting pseudodielectric function spectra were analyzed using a multilayer approach, describing the dielectric functions of the individual layers by a parametric oscillator model. From this analysis, the dielectric function spectra of GaN, Al x Ga 1-x N (x le 0.16), and In 0.13 Ga 0.87 N were deduced. Further, the dependence of the Al x Ga 1-x N band gap energy on the Al mole fraction was derived and compared with photoluminescence data recorded on the same material. The SE band gap data are compatible with a bowing parameter close to 1 eV for the composition dependence of the Al x Ga 1-x N gap energy. Finally, the parametric dielectric functions have been used to model the pseudodielectric function spectrum of a complete GaN/AlGaN/InGaN LED structure

  17. Multiscale modeling of nerve agent hydrolysis mechanisms: a tale of two Nobel Prizes

    Science.gov (United States)

    Field, Martin J.; Wymore, Troy W.

    2014-10-01

    The 2013 Nobel Prize in Chemistry was awarded for the development of multiscale models for complex chemical systems, whereas the 2013 Peace Prize was given to the Organisation for the Prohibition of Chemical Weapons for their efforts to eliminate chemical warfare agents. This review relates the two by introducing the field of multiscale modeling and highlighting its application to the study of the biological mechanisms by which selected chemical weapon agents exert their effects at an atomic level.

  18. InGaP/InGaAsN/GaAs NpN double-heterojunction bipolar transistor

    International Nuclear Information System (INIS)

    Chang, P. C.; Baca, A. G.; Li, N. Y.; Xie, X. M.; Hou, H. Q.; Armour, E.

    2000-01-01

    We have demonstrated a functional NpN double-heterojunction bipolar transistor (DHBT) using InGaAsN for the base layer. The InGaP/In 0.03 Ga 0.97 As 0.99 N 0.01 /GaAs DHBT has a low V ON of 0.81 V, which is 0.13 V lower than in a InGaP/GaAs heterojunction bipolar transistor (HBT). The lower turn-on voltage is attributed to the smaller band gap (1.20 eV) of metalorganic chemical vapor deposition-grown In 0.03 Ga 0.97 As 0.99 N 0.01 base layer. GaAs is used for the collector; thus the breakdown voltage (BV CEO ) is 10 V, consistent with the BV CEO of InGaP/GaAs HBTs of comparable collector thickness and doping level. To alleviate the current blocking phenomenon caused by the larger conduction band discontinuity between InGaAsN and GaAs, a graded InGaAs layer with δ doping is inserted at the base-collector junction. The improved device has a peak current gain of seven with ideal current-voltage characteristics. (c) 2000 American Institute of Physics

  19. Prospect Theory in the Heterogeneous Agent Model

    Czech Academy of Sciences Publication Activity Database

    Polach, J.; Kukačka, Jiří

    (2018) ISSN 1860-711X R&D Projects: GA ČR(CZ) GBP402/12/G097 Institutional support: RVO:67985556 Keywords : Heterogeneous Agent Model * Prospect Theory * Behavioral finance * Stylized facts Subject RIV: AH - Economic s OBOR OECD: Finance Impact factor: 0.931, year: 2016 http://library.utia.cas.cz/separaty/2018/E/kukacka-0488438.pdf

  20. Distribution of heparin-/sup 67/Ga in tumor-bearing rats

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, T; Ando, A; Sanada, S [Kanazawa Univ. (Japan). School of Paramedicine; Ando, I; Hisada, K

    1976-06-01

    Heparin is a kind of acidic mucopolysaccharide. The distribution of heparin-/sup 67/Ga complex in tumor-bearing rats was investigated by administering it to rats into which Yoshida sarcoma had been transplanted subcutaneously. These rats were sacrificed at 10 minutes, 30 minutes, 1 hour and 3 hours after injection. Radioactivity of the tumor, blood, muscle, liver, kidney, spleen and urine were measured with a well-type scintillation counter. Retention values in these organs and excretion rates in the urine were calculated. Excretion rates (%/dose) of heparin-/sup 67/Ga in 10 min., 30 min., 1 hour, and 3 hours were 38.2%, 67.5%, 79.5% and 78.0%, respectively. From these facts, it was thought that heparin-/sup 67/Ga complex was not suitable for tumor scanning, but that this compound might be a suitable agent for the renal function test.

  1. Combined KHFAC + DC nerve block without onset or reduced nerve conductivity after block

    Science.gov (United States)

    Franke, Manfred; Vrabec, Tina; Wainright, Jesse; Bhadra, Niloy; Bhadra, Narendra; Kilgore, Kevin

    2014-10-01

    Objective. Kilohertz frequency alternating current (KHFAC) waveforms have been shown to provide peripheral nerve conductivity block in many acute and chronic animal models. KHFAC nerve block could be used to address multiple disorders caused by neural over-activity, including blocking pain and spasticity. However, one drawback of KHFAC block is a transient activation of nerve fibers during the initiation of the nerve block, called the onset response. The objective of this study is to evaluate the feasibility of using charge balanced direct current (CBDC) waveforms to temporarily block motor nerve conductivity distally to the KHFAC electrodes to mitigate the block onset-response. Approach. A total of eight animals were used in this study. A set of four animals were used to assess feasibility and reproducibility of a combined KHFAC + CBDC block. A following randomized study, conducted on a second set of four animals, compared the onset response resulting from KHFAC alone and combined KHFAC + CBDC waveforms. To quantify the onset, peak forces and the force-time integral were measured during KHFAC block initiation. Nerve conductivity was monitored throughout the study by comparing muscle twitch forces evoked by supra-maximal stimulation proximal and distal to the block electrodes. Each animal of the randomized study received at least 300 s (range: 318-1563 s) of cumulative dc to investigate the impact of combined KHFAC + CBDC on nerve viability. Main results. The peak onset force was reduced significantly from 20.73 N (range: 18.6-26.5 N) with KHFAC alone to 0.45 N (range: 0.2-0.7 N) with the combined CBDC and KHFAC block waveform (p conductivity was observed after application of the combined KHFAC + CBDC block relative to KHFAC waveforms. Significance. The distal application of CBDC can significantly reduce or even completely prevent the KHFAC onset response without a change in nerve conductivity.

  2. Genetic modification of human sural nerve segments by a lentiviral vector encoding nerve growth factor

    NARCIS (Netherlands)

    Tannemaat, Martijn R; Boer, Gerard J; Verhaagen, J.; Malessy, Martijn J A

    2007-01-01

    OBJECTIVE: Autologous nerve grafts are used to treat severe peripheral nerve injury, but recovery of nerve function after grafting is rarely complete. Exogenous application of neurotrophic factors may enhance regeneration, but thus far the application of neurotrophic factors has been hampered by

  3. Comparing the Efficacy of Triple Nerve Transfers with Nerve Graft Reconstruction in Upper Trunk Obstetric Brachial Plexus Injury.

    Science.gov (United States)

    O'Grady, Kathleen M; Power, Hollie A; Olson, Jaret L; Morhart, Michael J; Harrop, A Robertson; Watt, M Joe; Chan, K Ming

    2017-10-01

    Upper trunk obstetric brachial plexus injury can cause profound shoulder and elbow dysfunction. Although neuroma excision with interpositional sural nerve grafting is the current gold standard, distal nerve transfers have a number of potential advantages. The goal of this study was to compare the clinical outcomes and health care costs between nerve grafting and distal nerve transfers in children with upper trunk obstetric brachial plexus injury. In this prospective cohort study, children who underwent triple nerve transfers were followed with the Active Movement Scale for 2 years. Their outcomes were compared to those of children who underwent nerve graft reconstruction. To assess health care use, a cost analysis was also performed. Twelve patients who underwent nerve grafting were compared to 14 patients who underwent triple nerve transfers. Both groups had similar baseline characteristics and showed improved shoulder and elbow function following surgery. However, the nerve transfer group displayed significantly greater improvement in shoulder external rotation and forearm supination 2 years after surgery (p The operative time and length of hospital stay were significantly lower (p the overall cost was approximately 50 percent less in the nerve transfer group. Triple nerve transfer for upper trunk obstetric brachial plexus injury is a feasible option, with better functional shoulder external rotation and forearm supination, faster recovery, and lower cost compared with traditional nerve graft reconstruction. Therapeutic, II.

  4. Foodborne illness among school children in Ga east, Accra | Malm ...

    African Journals Online (AJOL)

    Background: A food borne illness was reported in Ga- East district of Greater Accra Region among school children in May, 2007 after eating food provided at school. The objective of the investigation was to determine the source, mode of contamination and the causative agent. Methods: A case-control study was conducted, ...

  5. Effect of GaN buffer polarization on electron distribution of AlGaN/GaN heterostructure

    International Nuclear Information System (INIS)

    He, Xiaoguang; Zhao, Degang; Liu, Wei; Yang, Jing; Li, Xiaojing; Li, Xiang

    2016-01-01

    The formation of 2DEG in AlGaN/GaN heterostructure is discussed in detail. A misunderstanding about the 2DEG sheet density expression is clarified. It is predicted by theoretical analysis and validated by self-consistent Schrodinger–Poisson numerical simulation that under the force of GaN polarization, large amounts of electrons will accumulate at the GaN/substrate interface in AlGaN/GaN/substrate HEMT structure. - Highlights: • The formation of 2DEG in AlGaN/GaN heterostructure is discussed in detail. • Self-consistent Schrodinger–Poisson numerical simulation is used to modulate the AlGaN/GaN/substrate structure. • It is predicted by that large amounts of electrons will accumulate at the GaN/substrate interface.

  6. Effect of GaN buffer polarization on electron distribution of AlGaN/GaN heterostructure

    Energy Technology Data Exchange (ETDEWEB)

    He, Xiaoguang; Zhao, Degang, E-mail: dgzhao@red.semi.ac.cn; Liu, Wei; Yang, Jing; Li, Xiaojing; Li, Xiang

    2016-06-15

    The formation of 2DEG in AlGaN/GaN heterostructure is discussed in detail. A misunderstanding about the 2DEG sheet density expression is clarified. It is predicted by theoretical analysis and validated by self-consistent Schrodinger–Poisson numerical simulation that under the force of GaN polarization, large amounts of electrons will accumulate at the GaN/substrate interface in AlGaN/GaN/substrate HEMT structure. - Highlights: • The formation of 2DEG in AlGaN/GaN heterostructure is discussed in detail. • Self-consistent Schrodinger–Poisson numerical simulation is used to modulate the AlGaN/GaN/substrate structure. • It is predicted by that large amounts of electrons will accumulate at the GaN/substrate interface.

  7. Anatomy of the trigeminal nerve

    NARCIS (Netherlands)

    van Eijden, T.M.G.J.; Langenbach, G.E.J.; Baart, J.A.; Brand, H.S.

    2017-01-01

    The trigeminal nerve is the fifth cranial nerve (n. V), which plays an important role in the innervation of the head and neck area, together with other cranial and spinal nerves. Knowledge of the nerve’s anatomy is very important for the correct application of local anaesthetics.

  8. Sciatic nerve regeneration in rats by a promising electrospun collagen/poly(ε-caprolactone nerve conduit with tailored degradation rate

    Directory of Open Access Journals (Sweden)

    Jiang Xinquan

    2011-07-01

    Full Text Available Abstract Background To cope with the limitations faced by autograft acquisitions particularly for multiple nerve injuries, artificial nerve conduit has been introduced by researchers as a substitute for autologous nerve graft for the easy specification and availability for mass production. In order to best mimic the structures and components of autologous nerve, great efforts have been made to improve the designation of nerve conduits either from materials or fabrication techniques. Electrospinning is an easy and versatile technique that has recently been used to fabricate fibrous tissue-engineered scaffolds which have great similarity to the extracellular matrix on fiber structure. Results In this study we fabricated a collagen/poly(ε-caprolactone (collagen/PCL fibrous scaffold by electrospinning and explored its application as nerve guide substrate or conduit in vitro and in vivo. Material characterizations showed this electrospun composite material which was made of submicron fibers possessed good hydrophilicity and flexibility. In vitro study indicated electrospun collagen/PCL fibrous meshes promoted Schwann cell adhesion, elongation and proliferation. In vivo test showed electrospun collagen/PCL porous nerve conduits successfully supported nerve regeneration through an 8 mm sciatic nerve gap in adult rats, achieving similar electrophysiological and muscle reinnervation results as autografts. Although regenerated nerve fibers were still in a pre-mature stage 4 months postoperatively, the implanted collagen/PCL nerve conduits facilitated more axons regenerating through the conduit lumen and gradually degraded which well matched the nerve regeneration rate. Conclusions All the results demonstrated this collagen/PCL nerve conduit with tailored degradation rate fabricated by electrospinning could be an efficient alternative to autograft for peripheral nerve regeneration research. Due to its advantage of high surface area for cell attachment, it

  9. Gasserian Ganglion and Retrobulbar Nerve Block in the Treatment of Ophthalmic Postherpetic Neuralgia: A Case Report.

    Science.gov (United States)

    Huang, Jie; Ni, Zhongge; Finch, Philip

    2017-09-01

    Varicella zoster virus reactivation can cause permanent histological changes in the central and peripheral nervous system. Neural inflammatory changes or damage to the dorsal root ganglia sensory nerve fibers during reactivation can lead to postherpetic neuralgia (PHN). For PHN of the first division of the fifth cranial nerve (ophthalmic division of the trigeminal ganglion), there is evidence of inflammatory change in the ganglion and adjacent ocular neural structures. First division trigeminal nerve PHN can prove to be difficult and sometimes even impossible to manage despite the use of a wide range of conservative measures, including anticonvulsant and antidepressant medication. Steroids have been shown to play an important role by suppressing neural inflammatory processes. We therefore chose the trigeminal ganglion as an interventional target for an 88-year-old woman with severe ophthalmic division PHN after she failed to respond to conservative treatment. Under fluoroscopic guidance, a trigeminal ganglion nerve block was performed with lidocaine combined with dexamethasone. A retrobulbar block with lidocaine and triamcinolone settled residual oculodynia. At 1-year follow-up, the patient remained pain free and did not require analgesic medication. To our knowledge, this is the first reported case of ophthalmic division PHN successfully treated with a combination of trigeminal ganglion and retrobulbar nerve block using a local anesthetic agent and steroid for central and peripheral neural inflammatory processes. © 2016 World Institute of Pain.

  10. Inferior alveolar nerve block: Alternative technique.

    Science.gov (United States)

    Thangavelu, K; Kannan, R; Kumar, N Senthil

    2012-01-01

    Inferior alveolar nerve block (IANB) is a technique of dental anesthesia, used to produce anesthesia of the mandibular teeth, gingivae of the mandible and lower lip. The conventional IANB is the most commonly used the nerve block technique for achieving local anesthesia for mandibular surgical procedures. In certain cases, however, this nerve block fails, even when performed by the most experienced clinician. Therefore, it would be advantageous to find an alternative simple technique. The objective of this study is to find an alternative inferior alveolar nerve block that has a higher success rate than other routine techniques. To this purpose, a simple painless inferior alveolar nerve block was designed to anesthetize the inferior alveolar nerve. This study was conducted in Oral surgery department of Vinayaka Mission's dental college Salem from May 2009 to May 2011. Five hundred patients between the age of 20 years and 65 years who required extraction of teeth in mandible were included in the study. Out of 500 patients 270 were males and 230 were females. The effectiveness of the IANB was evaluated by using a sharp dental explorer in the regions innervated by the inferior alveolar, lingual, and buccal nerves after 3, 5, and 7 min, respectively. This study concludes that inferior alveolar nerve block is an appropriate alternative nerve block to anesthetize inferior alveolar nerve due to its several advantages.

  11. Functional Outcomes of Multiple Sural Nerve Grafts for Facial Nerve Defects after Tumor-Ablative Surgery

    Directory of Open Access Journals (Sweden)

    Myung Chul Lee

    2015-07-01

    Full Text Available BackgroundFunctional restoration of the facial expression is necessary after facial nerve resection to treat head and neck tumors. This study was conducted to evaluate the functional outcomes of patients who underwent facial nerve cable grafting immediately after tumor resection.MethodsPatients who underwent cable grafting from April 2007 to August 2011 were reviewed, in which a harvested branch of the sural nerve was grafted onto each facial nerve division. Twelve patients underwent facial nerve cable grafting after radical parotidectomy, total parotidectomy, or schwannoma resection, and the functional facial expression of each patient was evaluated using the Facial Nerve Grading Scale 2.0. The results were analyzed according to patient age, follow-up duration, and the use of postoperative radiation therapy.ResultsAmong the 12 patients who were evaluated, the mean follow-up duration was 21.8 months, the mean age at the time of surgery was 42.8 years, and the mean facial expression score was 14.6 points, indicating moderate dysfunction. Facial expression scores were not influenced by age at the time of surgery, follow-up duration, or the use of postoperative radiation therapy.ConclusionsThe results of this study indicate that facial nerve cable grafting using the sural nerve can restore facial expression. Although patients were provided with appropriate treatment, the survival rate for salivary gland cancer was poor. We conclude that immediate facial nerve reconstruction is a worthwhile procedure that improves quality of life by allowing the recovery of facial expression, even in patients who are older or may require radiation therapy.

  12. Muscle potentials evoked by magnetic stimulation of the sciatic nerve in unilateral sciatic nerve dysfunction

    NARCIS (Netherlands)

    Van Soens, I.; Struys, M. M. R. F.; Van Ham, L. M. L.

    Magnetic stimulation of the sciatic nerve and subsequent recording of the muscle-evoked potential (MEP) was performed in eight dogs and three cats with unilateral sciatic nerve dysfunction. Localisation of the lesion in the sciatic nerve was based on the history, clinical neurological examination

  13. A biosynthetic nerve guide conduit based on silk/SWNT/fibronectin nanocomposite for peripheral nerve regeneration.

    Directory of Open Access Journals (Sweden)

    Fatemeh Mottaghitalab

    Full Text Available As a contribution to the functionality of nerve guide conduits (NGCs in nerve tissue engineering, here we report a conduit processing technique through introduction and evaluation of topographical, physical and chemical cues. Porous structure of NGCs based on freeze-dried silk/single walled carbon nanotubes (SF/SWNTs has shown a uniform chemical and physical structure with suitable electrical conductivity. Moreover, fibronectin (FN containing nanofibers within the structure of SF/SWNT conduits produced through electrospinning process have shown aligned fashion with appropriate porosity and diameter. Moreover, fibronectin remained its bioactivity and influenced the adhesion and growth of U373 cell lines. The conduits were then implanted to 10 mm left sciatic nerve defects in rats. The histological assessment has shown that nerve regeneration has taken places in proximal region of implanted nerve after 5 weeks following surgery. Furthermore, nerve conduction velocities (NCV and more myelinated axons were observed in SF/SWNT and SF/SWNT/FN groups after 5 weeks post implantation, indicating a functional recovery for the injured nerves. With immunohistochemistry, the higher S-100 expression of Schwann cells in SF/SWNT/FN conduits in comparison to other groups was confirmed. In conclusion, an oriented conduit of biocompatible SF/SWNT/FN has been fabricated with acceptable structure that is particularly applicable in nerve grafts.

  14. Neuroprotective effects of ultrasound-guided nerve growth factor injections after sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Hong-fei Li

    2015-01-01

    Full Text Available Nerve growth factor (NGF plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effective mode of administration. High-frequency ultrasound (HFU is increasingly used in the clinic for high-resolution visualization of tissues, and has been proposed as a method for identifying and evaluating peripheral nerve damage after injury. In addition, HFU is widely used for guiding needle placement when administering drugs to a specific site. We hypothesized that HFU guiding would optimize the neuroprotective effects of NGF on sciatic nerve injury in the rabbit. We performed behavioral, ultrasound, electrophysiological, histological, and immunohistochemical evaluation of HFU-guided NGF injections administered immediately after injury, or 14 days later, and compared this mode of administration with intramuscular NGF injections. Across all assessments, HFU-guided NGF injections gave consistently better outcomes than intramuscular NGF injections administered immediately or 14 days after injury, with immediate treatment also yielding better structural and functional results than when the treatment was delayed by 14 days. Our findings indicate that NGF should be administered as early as possible after peripheral nerve injury, and highlight the striking neuroprotective effects of HFU-guided NGF injections on peripheral nerve injury compared with intramuscular administration.

  15. Optic nerve invasion of uveal melanoma

    DEFF Research Database (Denmark)

    Lindegaard, Jens; Isager, Peter; Prause, Jan Ulrik

    2007-01-01

    in Denmark between 1942 and 2001 were reviewed (n=157). Histopathological characteristics and depth of optic nerve invasion were recorded. The material was compared with a control material from the same period consisting of 85 cases randomly drawn from all choroidal/ciliary body melanomas without optic nerve...... juxtapapillary tumors invading the optic nerve because of simple proximity to the nerve. A neurotropic subtype invades the optic nerve and retina in a diffuse fashion unrelated to tumor size or location. Udgivelsesdato: 2007-Jan...

  16. Neurotization of the phrenic nerve with accessory nerve for high cervical spinal cord injury with respiratory distress: an anatomic study.

    Science.gov (United States)

    Wang, Ce; Zhang, Ying; Nicholas, Tsai; Wu, Guoxin; Shi, Sheng; Bo, Yin; Wang, Xinwei; Zhou, Xuhui; Yuan, Wen

    2014-01-01

    High cervical spinal cord injury is associated with high morbidity and mortality. Traditional treatments carry various complications such as infection, pacemaker failure and undesirable movement. Thus, a secure surgical strategy with fewer complications analogous to physiological ventilation is still required. We hope to offer one potential method to decrease the complications and improve survival qualities of patients from the aspect of anatomy. The purpose of the study is to provide anatomic details on the accessory nerve and phrenic nerve for neurotization in patients with high spinal cord injuries. 38 cadavers (76 accessory and 76 phrenic nerves) were dissected in the study. The width, length and thickness of each accessory nerve and phrenic nerve above clavicle were measured. The distances from several landmarks on accessory nerve to the origin and the end of the phrenic nerve above clavicle were measured too. Then, the number of motor nerve fibers on different sections of the nerves was calculated using the technique of immunohistochemistry. The accessory nerves distal to its sternocleidomastoid muscular branches were 1.52 ± 0.32 mm ~1.54 ± 0.29 mm in width, 0.52 ± 0.18 mm ~ 0.56 ± 0.20mm in thickness and 9.52 ± 0.98 cm in length. And the phrenic nerves above clavicle were 1.44 ± 0.23 mm ~ 1.45 ± 0.24 mm in width, 0.47 ± 0.15 mm ~ 0.56 ± 0.25 mm in thickness and 6.48 ± 0.78 cm in length. The distance between the starting point of accessory nerve and phrenic nerve were 3.24 ± 1.17 cm, and the distance between the starting point of accessory nerve and the end of the phrenic nerve above clavicle were 8.72 ± 0.84 cm. The numbers of motor nerve fibers in accessory nerve were 1,038 ± 320~1,102 ± 216, before giving out the sternocleidomastoid muscular branches. The number of motor nerve fibers in the phrenic nerve was 911 ± 321~1,338 ± 467. The accessory nerve and the phrenic were similar in width, thickness and the number of motor nerve fibers. And

  17. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  18. Arthroscopic medial meniscus trimming or repair under nerve blocks: Which nerves should be blocked?

    Science.gov (United States)

    Taha, AM; Abd-Elmaksoud, AM

    2016-01-01

    Background: This study aimed to determine the role of the sciatic and obturator nerve blocks (in addition to femoral block) in providing painless arthroscopic medial meniscus trimming/repair. Materials and Methods: One hundred and twenty patients with medial meniscus tear, who had been scheduled to knee arthroscopy, were planned to be included in this controlled prospective double-blind study. The patients were randomly allocated into three equal groups; FSO, FS, and FO. The femoral, sciatic, and obturator nerves were blocked in FSO groups. The femoral and sciatic nerves were blocked in FS group, while the femoral and obturator nerves were blocked in FO group. Intraoperative pain and its causative surgical maneuver were recorded. Results: All the patients (n = 7, 100%) in FO group had intraoperative pain. The research was terminated in this group but completed in FS and FSO groups (40 patients each). During valgus positioning of the knee for surgical management of the medial meniscus tear, the patients in FS group experienced pain more frequently than those in FSO group (P = 0.005). Conclusion: Adding a sciatic nerve block to the femoral nerve block is important for painless knee arthroscopy. Further adding of an obturator nerve block may be needed when a valgus knee position is required to manage the medial meniscus tear. PMID:27375382

  19. Magnetic resonance imaging of optic nerve

    International Nuclear Information System (INIS)

    Gala, Foram

    2015-01-01

    Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI), plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies

  20. Cranial nerve involvement in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Oezyar, E.; Atahan, I.L.; Akyol, F.H.; Guerkaynak, M.; Zorlu, A.F.

    1994-01-01

    Between 1975 and 1989, 23 nasopharyngeal carcinoma patients presenting with cranial nerve involvement (CNI) of one or more nerves at the time of diagnosis were treated and followed-up in our department. All patients were irradiated with curative intent, and total doses of 50 to 70 Gy (median 65 Gy) were delivered to the nasopharynx. Cranial nerves VI, III, V, IV, IX, and XII were the most commonly involved nerves. The total response rate of cranial nerves was 74% in a median follow-up time of 2 years, with the highest rate observed in the third and sixth cranial nerves. All complete responses except two were observed in the first month after radiotherapy. (author)

  1. Growth of InGaN multiple quantum wells and GaN eplilayer on GaN substrate

    International Nuclear Information System (INIS)

    Lee, Sung-Nam; Paek, H.S.; Son, J.K.; Sakong, T.; Yoon, E.; Nam, O.H.; Park, Y.

    2006-01-01

    We investigated that the surface morphology of GaN epilayers was significantly affected by the surface tilt orientation of GaN substrate. Surface morphologies of GaN epilayers on GaN substrates show three types: mirror, wavy, and hillock. These surface morphologies are dependent on the surface orientation of GaN substrates. It is found that the hillock morphology of GaN epilayer was formed on the GaN substrate with surface tilt orientation less than 0.1 o . As the surface tilt angle increased to 0.35 o , the surface morphology varied from hillock to wavy morphology. Above a surface tilt angle of 0.4 o , surface morphology changed to the mirror-like type morphology. Additionally, these three types of GaN surface morphology also affected the optical quality of GaN epilayers as well as InGaN multiple quantum wells on GaN substrates by non-uniform In incorporation on the different surface morphologies of GaN epilayers

  2. Determination of HEPES in 68Ga-labeled peptide solutions

    International Nuclear Information System (INIS)

    Revital Sasson; Dan Vaknin; Avihai Bross; Efraim Lavie

    2010-01-01

    A practical and reliable HPLC method was used for the determination of 2-[4-N-(2-hydroxyethyl)-1-piperazinyl]-N'-ethanesulfonic acid (HEPES) content in the 68 Ga-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-Nal3-octreotide (DOTANOC). Linearity of this method was observed in a concentration range of 0.01-10 mg mL -1 and the quantitative limit (signal to noise = 11) was determined as 10 μg mL -1 . The HEPES concentration in the final products of 68 Ga-DOTANOC was typically lower than the detection limit. Pure water and HEPES buffer as reaction medium were investigated using various activities of gallium-68. It was demonstrated that the presence of HEPES buffer consistently furnished very high radiochemical purity of 68 Ga-DOTANOC, which remained stable for several hours post-labeling. Evidence is provided that in addition to its role as a buffer, HEPES also functions as a radioprotectant agent. (author)

  3. Neuroprotective Drug for Nerve Trauma Revealed Using Artificial Intelligence.

    Science.gov (United States)

    Romeo-Guitart, David; Forés, Joaquim; Herrando-Grabulosa, Mireia; Valls, Raquel; Leiva-Rodríguez, Tatiana; Galea, Elena; González-Pérez, Francisco; Navarro, Xavier; Petegnief, Valerie; Bosch, Assumpció; Coma, Mireia; Mas, José Manuel; Casas, Caty

    2018-01-30

    Here we used a systems biology approach and artificial intelligence to identify a neuroprotective agent for the treatment of peripheral nerve root avulsion. Based on accumulated knowledge of the neurodegenerative and neuroprotective processes that occur in motoneurons after root avulsion, we built up protein networks and converted them into mathematical models. Unbiased proteomic data from our preclinical models were used for machine learning algorithms and for restrictions to be imposed on mathematical solutions. Solutions allowed us to identify combinations of repurposed drugs as potential neuroprotective agents and we validated them in our preclinical models. The best one, NeuroHeal, neuroprotected motoneurons, exerted anti-inflammatory properties and promoted functional locomotor recovery. NeuroHeal endorsed the activation of Sirtuin 1, which was essential for its neuroprotective effect. These results support the value of network-centric approaches for drug discovery and demonstrate the efficacy of NeuroHeal as adjuvant treatment with surgical repair for nervous system trauma.

  4. AlGaAs/InGaAs/AlGaAs double pulse doped pseudomorphic high electron mobility transistor structures on InGaAs substrates

    Science.gov (United States)

    Hoke, W. E.; Lyman, P. S.; Mosca, J. J.; McTaggart, R. A.; Lemonias, P. J.; Beaudoin, R. M.; Torabi, A.; Bonner, W. A.; Lent, B.; Chou, L.-J.; Hsieh, K. C.

    1997-10-01

    Double pulse doped AlGaAs/InGaAs/AlGaAs pseudomorphic high electron mobility transistor (PHEMT) structures have been grown on InxGa1-xAs (x=0.025-0.07) substrates using molecular beam epitaxy. A strain compensated, AlGaInAs/GaAs superlattice was used for improved resistivity and breakdown. Excellent electrical and optical properties were obtained for 110-Å-thick InGaAs channel layers with indium concentrations up to 31%. A room temperature mobility of 6860 cm2/V s with 77 K sheet density of 4.0×1012cm-2 was achieved. The InGaAs channel photoluminescence intensity was equivalent to an analogous structure on a GaAs substrate. To reduce strain PHEMT structures with a composite InGaP/AlGaAs Schottky layer were also grown. The structures also exhibited excellent electrical and optical properties. Transmission electron micrographs showed planar channel interfaces for highly strained In0.30Ga0.70As channel layers.

  5. Ion mobility spectrometric analysis of vaporous chemical warfare agents by the instrument with corona discharge ionization ammonia dopant ambient temperature operation.

    Science.gov (United States)

    Satoh, Takafumi; Kishi, Shintaro; Nagashima, Hisayuki; Tachikawa, Masumi; Kanamori-Kataoka, Mieko; Nakagawa, Takao; Kitagawa, Nobuyoshi; Tokita, Kenichi; Yamamoto, Soichiro; Seto, Yasuo

    2015-03-20

    The ion mobility behavior of nineteen chemical warfare agents (7 nerve gases, 5 blister agents, 2 lachrymators, 2 blood agents, 3 choking agents) and related compounds including simulants (8 agents) and organic solvents (39) was comparably investigated by the ion mobility spectrometry instrument utilizing weak electric field linear drift tube with corona discharge ionization, ammonia doping, purified inner air drift flow circulation operated at ambient temperature and pressure. Three alkyl methylphosphonofluoridates, tabun, and four organophosphorus simulants gave the intense characteristic positive monomer-derived ion peaks and small dimer-derived ion peaks, and the later ion peaks were increased with the vapor concentrations. VX, RVX and tabun gave both characteristic positive monomer-derived ions and degradation product ions. Nitrogen mustards gave the intense characteristic positive ion peaks, and in addition distinctive negative ion peak appeared from HN3. Mustard gas, lewisite 1, o-chlorobenzylidenemalononitrile and 2-mercaptoethanol gave the characteristic negative ion peaks. Methylphosphonyl difluoride, 2-chloroacetophenone and 1,4-thioxane gave the characteristic ion peaks both in the positive and negative ion mode. 2-Chloroethylethylsulfide and allylisothiocyanate gave weak ion peaks. The marker ion peaks derived from two blood agents and three choking agents were very close to the reactant ion peak in negative ion mode and the respective reduced ion mobility was fluctuated. The reduced ion mobility of the CWA monomer-derived peaks were positively correlated with molecular masses among structurally similar agents such as G-type nerve gases and organophosphorus simulants; V-type nerve gases and nitrogen mustards. The slope values of the calibration plots of the peak heights of the characteristic marker ions versus the vapor concentrations are related to the detection sensitivity, and within chemical warfare agents examined the slope values for sarin, soman

  6. Two new Np--Ga phases: α-NpGa2 and metastable m-NpGa2

    International Nuclear Information System (INIS)

    Giessen, B.C.; Elliott, R.O.

    1976-01-01

    Following an earlier study of metastable Np-rich Np--Ga alloys, rapidly quenched Np--Ga alloys with 63 to 80 at. pct. Ga were prepared and studied. Two new NpGa 2 phases, both with an AlB 2 type structure, were found: α-NpGa 2 , with a = 4.246A, c = 4.060A, c/a = 0.956, and m-NpGa 2 , with a = 4.412A, c = 3.642A, c/a = 0.825. While m-NpGa 2 was observed only in very fast quenched (splat cooled) samples and appears to be metastable, α-NpGa 2 is probably an equilibrium phase. In a splat cooled alloy with 75 at. pct. Ga, another, unidentified, metastable phase was observed. Crystal chemical discussions of atomic volumes, interatomic distances and axial ratios are given; the volume difference between the two forms of NpGa 2 is correlated with a valence change of Np

  7. Tractography of lumbar nerve roots: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Balbi, Vincent; Budzik, Jean-Francois; Thuc, Vianney le; Cotten, Anne [Hopital Roger Salengro, Service de Radiologie et d' Imagerie musculo-squelettique, Lille Cedex (France); Duhamel, Alain [Universite de Lille 2, UDSL, Lille (France); Bera-Louville, Anne [Service de Rhumatologie, Hopital Roger Salengro, Lille (France)

    2011-06-15

    The aims of this preliminary study were to demonstrate the feasibility of in vivo diffusion tensor imaging (DTI) and fibre tracking (FT) of the lumbar nerve roots, and to assess potential differences in the DTI parameters of the lumbar nerves between healthy volunteers and patients suffering from disc herniation. Nineteen patients with unilateral sciatica related to posterolateral or foraminal disc herniation and 19 healthy volunteers were enrolled in this study. DTI with tractography of the L5 or S1 nerves was performed. Mean fractional anisotropy (FA) and mean diffusivity (MD) values were calculated from tractography images. FA and MD values could be obtained from DTI-FT images in all controls and patients. The mean FA value of the compressed lumbar nerve roots was significantly lower than the FA of the contralateral nerve roots (p=0.0001) and of the nerve roots of volunteers (p=0.0001). MD was significantly higher in compressed nerve roots than in the contralateral nerve root (p=0.0002) and in the nerve roots of volunteers (p=0.04). DTI with tractography of the lumbar nerves is possible. Significant changes in diffusion parameters were found in the compressed lumbar nerves. (orig.)

  8. Tractography of lumbar nerve roots: initial results

    International Nuclear Information System (INIS)

    Balbi, Vincent; Budzik, Jean-Francois; Thuc, Vianney le; Cotten, Anne; Duhamel, Alain; Bera-Louville, Anne

    2011-01-01

    The aims of this preliminary study were to demonstrate the feasibility of in vivo diffusion tensor imaging (DTI) and fibre tracking (FT) of the lumbar nerve roots, and to assess potential differences in the DTI parameters of the lumbar nerves between healthy volunteers and patients suffering from disc herniation. Nineteen patients with unilateral sciatica related to posterolateral or foraminal disc herniation and 19 healthy volunteers were enrolled in this study. DTI with tractography of the L5 or S1 nerves was performed. Mean fractional anisotropy (FA) and mean diffusivity (MD) values were calculated from tractography images. FA and MD values could be obtained from DTI-FT images in all controls and patients. The mean FA value of the compressed lumbar nerve roots was significantly lower than the FA of the contralateral nerve roots (p=0.0001) and of the nerve roots of volunteers (p=0.0001). MD was significantly higher in compressed nerve roots than in the contralateral nerve root (p=0.0002) and in the nerve roots of volunteers (p=0.04). DTI with tractography of the lumbar nerves is possible. Significant changes in diffusion parameters were found in the compressed lumbar nerves. (orig.)

  9. A microneedle biosensor for minimally-invasive transdermal detection of nerve agents.

    Science.gov (United States)

    Mishra, Rupesh K; Vinu Mohan, A M; Soto, Fernando; Chrostowski, Robert; Wang, Joseph

    2017-03-13

    A microneedle electrochemical biosensor for the minimally invasive detection of organophosphate (OP) chemical agents is described. The new sensor relies on the coupling of the effective biocatalytic action of organophosphorus hydrolase (OPH) with a hollow-microneedle modified carbon-paste array electrode transducer, and involves rapid square-wave voltammetric (SWV) measurements of the p-nitrophenol product of the OPH enzymatic reaction in the presence of the OP substrate. The scanning-potential SWV transduction mode offers an additional dimension of selectivity compared to common fixed-potential OPH-amperometric biosensors. The microneedle device offers a highly linear response for methyl paraoxon (MPOx) over the range of 20-180 μM, high selectivity in the presence of excess co-existing ascorbic acid and uric acid and a high stability sensor upon exposure to the interstitial fluid (ISF). The OPH microneedle sensor was successfully tested ex vivo using mice skin samples exposed to MPOx, demonstrating its promise for minimally-invasive monitoring of OP agents and pesticides and as a wearable sensor for detecting toxic compounds, in general.

  10. [Imaging anatomy of cranial nerves].

    Science.gov (United States)

    Hermier, M; Leal, P R L; Salaris, S F; Froment, J-C; Sindou, M

    2009-04-01

    Knowledge of the anatomy of the cranial nerves is mandatory for optimal radiological exploration and interpretation of the images in normal and pathological conditions. CT is the method of choice for the study of the skull base and its foramina. MRI explores the cranial nerves and their vascular relationships precisely. Because of their small size, it is essential to obtain images with high spatial resolution. The MRI sequences optimize contrast between nerves and surrounding structures (cerebrospinal fluid, fat, bone structures and vessels). This chapter discusses the radiological anatomy of the cranial nerves.

  11. Factors that influence peripheral nerve regeneration

    DEFF Research Database (Denmark)

    Krarup, Christian; Archibald, Simon J; Madison, Roger D

    2002-01-01

    median nerve lesions (n = 46) in nonhuman primates over 3 to 4 years, a time span comparable with such lesions in humans. Nerve gap distances of 5, 20, or 50mm were repaired with nerve grafts or collagen-based nerve guide tubes, and three electrophysiological outcome measures were followed: (1) compound...... muscle action potentials in the abductor pollicis brevis muscle, (2) the number and size of motor units in reinnervated muscle, and (3) compound sensory action potentials from digital nerve. A statistical model was used to assess the influence of three variables (repair type, nerve gap distance, and time...... to earliest muscle reinnervation) on the final recovery of the outcome measures. Nerve gap distance and the repair type, individually and concertedly, strongly influenced the time to earliest muscle reinnervation, and only time to reinnervation was significant when all three variables were included as outcome...

  12. Suprascapular nerve entrapment in newsreel cameramen.

    Science.gov (United States)

    Karataş, Gülçin Kaymak; Göğüş, Feride

    2003-03-01

    To determine presence of suprascapular nerve entrapment in a group of newsreel cameramen. Thirty-six men working as newsreel cameramen participated in the study. In addition to musculoskeletal and neurologic examinations, bilateral suprascapular nerve conduction studies and needle electromyography were performed. A group of 19 healthy, male volunteers were included in the study as normal controls for suprascapular nerve conduction studies. In newsreel cameramen, mean suprascapular nerve latency was 3.20 +/- 0.56 msec and 2.84 +/- 0.36 msec for right and left shoulders, respectively (P = 0.001). The mean latency difference between right and left suprascapular nerves was -0.05 +/- 0.19 msec in the control group and 0.36 +/- 0.58 msec in the cameramen group (P mobile camera on the shoulder might cause suprascapular nerve entrapment in newsreel cameramen. This could be considered an occupational disorder of the suprascapular nerve, like meat-packer's neuropathy.

  13. Biodegradable p(DLLA-epsilon-CL) nerve guides versus autologous nerve grafts : Electromyographic and video analysis

    NARCIS (Netherlands)

    Meek, MF; Nicolai, JPA; Gramsbergen, A; van der Werf, J.F.A.

    The aim of this study was to evaluate the functional effects of bridging a gap in the sciatic nerve of the rat with either a biodegradable copolymer of (DL)-lactide and epsilon -caprolactone [p(DLLA-epsilon -CL)] nerve guide or an autologous nerve graft. Electromyograms (EMGs) of the gastrocnemius

  14. Transient delayed facial nerve palsy after inferior alveolar nerve block anesthesia.

    Science.gov (United States)

    Tzermpos, Fotios H; Cocos, Alina; Kleftogiannis, Matthaios; Zarakas, Marissa; Iatrou, Ioannis

    2012-01-01

    Facial nerve palsy, as a complication of an inferior alveolar nerve block anesthesia, is a rarely reported incident. Based on the time elapsed, from the moment of the injection to the onset of the symptoms, the paralysis could be either immediate or delayed. The purpose of this article is to report a case of delayed facial palsy as a result of inferior alveolar nerve block, which occurred 24 hours after the anesthetic administration and subsided in about 8 weeks. The pathogenesis, treatment, and results of an 8-week follow-up for a 20-year-old patient referred to a private maxillofacial clinic are presented and discussed. The patient's previous medical history was unremarkable. On clinical examination the patient exhibited generalized weakness of the left side of her face with a flat and expressionless appearance, and she was unable to close her left eye. One day before the onset of the symptoms, the patient had visited her dentist for a routine restorative procedure on the lower left first molar and an inferior alveolar block anesthesia was administered. The patient's medical history, clinical appearance, and complete examinations led to the diagnosis of delayed facial nerve palsy. Although neurologic occurrences are rare, dentists should keep in mind that certain dental procedures, such as inferior alveolar block anesthesia, could initiate facial nerve palsy. Attention should be paid during the administration of the anesthetic solution.

  15. Trigeminal neuralgia and facial nerve paralysis

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandra [IPOFG, Department of Radiology, Lisbon (Portugal)

    2005-03-01

    The trigeminal nerve is the largest of the cranial nerves. It provides sensory input from the face and motor innervation to the muscles of mastication. The facial nerve is the cranial nerve with the longest extracranial course, and its main functions include motor innervation to the muscles of facial expression, sensory control of lacrimation and salivation, control of the stapedial reflex and to carry taste sensation from the anterior two-thirds of the tongue. In order to be able adequately to image and follow the course of these cranial nerves and their main branches, a detailed knowledge of neuroanatomy is required. As we are dealing with very small anatomic structures, high resolution dedicated imaging studies are required to pick up normal and pathologic nerves. Whereas CT is best suited to demonstrate bony neurovascular foramina and canals, MRI is preferred to directly visualize the nerve. It is also the single technique able to detect pathologic processes afflicting the nerve without causing considerable expansion such as is usually the case in certain inflammatory/infectious conditions, perineural spread of malignancies and in very small intrinsic tumours. Because a long course from the brainstem nuclei to the peripheral branches is seen, it is useful to subdivide the nerve in several segments and then tailor the imaging modality and the imaging study to that specific segment. This is particularly true in cases where topographic diagnosis can be used to locate a lesion in the course of these nerves. (orig.)

  16. Axillary nerve injury associated with sports.

    Science.gov (United States)

    Lee, Sangkook; Saetia, Kriangsak; Saha, Suparna; Kline, David G; Kim, Daniel H

    2011-11-01

    The aim of this retrospective study was to present and investigate axillary nerve injuries associated with sports. This study retrospectively reviewed 26 axillary nerve injuries associated with sports between the years 1985 and 2010. Preoperative status of the axillary nerve was evaluated by using the Louisiana State University Health Science Center (LSUHSC) grading system published by the senior authors. Intraoperative nerve action potential recordings were performed to check nerve conduction and assess the possibility of resection. Neurolysis, suture, and nerve grafts were used for the surgical repair of the injured nerves. In 9 patients with partial loss of function and 3 with complete loss, neurolysis based on nerve action potential recordings was the primary treatment. Two patients with complete loss of function were treated with resection and suturing and 12 with resection and nerve grafting. The minimum follow-up period was 16 months (mean 20 months). The injuries were associated with the following sports: skiing (12 cases), football (5), rugby (2), baseball (2), ice hockey (2), soccer (1), weightlifting (1), and wrestling (1). Functional recovery was excellent. Neurolysis was performed in 9 cases, resulting in an average functional recovery of LSUHSC Grade 4.2. Recovery with graft repairs averaged LSUHSC Grade 3 or better in 11 of 12 cases Surgical repair can restore useful deltoid function in patients with sports-associated axillary nerve injuries, even in cases of severe stretch-contusion injury.

  17. Trigeminal neuralgia and facial nerve paralysis

    International Nuclear Information System (INIS)

    Borges, Alexandra

    2005-01-01

    The trigeminal nerve is the largest of the cranial nerves. It provides sensory input from the face and motor innervation to the muscles of mastication. The facial nerve is the cranial nerve with the longest extracranial course, and its main functions include motor innervation to the muscles of facial expression, sensory control of lacrimation and salivation, control of the stapedial reflex and to carry taste sensation from the anterior two-thirds of the tongue. In order to be able adequately to image and follow the course of these cranial nerves and their main branches, a detailed knowledge of neuroanatomy is required. As we are dealing with very small anatomic structures, high resolution dedicated imaging studies are required to pick up normal and pathologic nerves. Whereas CT is best suited to demonstrate bony neurovascular foramina and canals, MRI is preferred to directly visualize the nerve. It is also the single technique able to detect pathologic processes afflicting the nerve without causing considerable expansion such as is usually the case in certain inflammatory/infectious conditions, perineural spread of malignancies and in very small intrinsic tumours. Because a long course from the brainstem nuclei to the peripheral branches is seen, it is useful to subdivide the nerve in several segments and then tailor the imaging modality and the imaging study to that specific segment. This is particularly true in cases where topographic diagnosis can be used to locate a lesion in the course of these nerves. (orig.)

  18. Recovery of the sub-basal nerve plexus and superficial nerve terminals after corneal epithelial injury in mice.

    Science.gov (United States)

    Downie, Laura E; Naranjo Golborne, Cecilia; Chen, Merry; Ho, Ngoc; Hoac, Cam; Liyanapathirana, Dasun; Luo, Carol; Wu, Ruo Bing; Chinnery, Holly R

    2018-06-01

    Our aim was to compare regeneration of the sub-basal nerve plexus (SBNP) and superficial nerve terminals (SNT) following corneal epithelial injury. We also sought to compare agreement when quantifying nerve parameters using different image analysis techniques. Anesthetized, female C57BL/6 mice received central 1-mm corneal epithelial abrasions. Four-weeks post-injury, eyes were enucleated and processed for PGP9.5 to visualize the corneal nerves using wholemount immunofluorescence staining and confocal microscopy. The percentage area of the SBNP and SNT were quantified using: ImageJ automated thresholds, ImageJ manual thresholds and manual tracings in NeuronJ. Nerve sum length was quantified using NeuronJ and Imaris. Agreement between methods was considered with Bland-Altman analyses. Four-weeks post-injury, the sum length of nerve fibers in the SBNP, but not the SNT, was reduced compared with naïve eyes. In the periphery, but not central cornea, of both naïve and injured eyes, nerve fiber lengths in the SBNP and SNT were strongly correlated. For quantifying SBNP nerve axon area, all image analysis methods were highly correlated. In the SNT, there was poor correlation between manual methods and auto-thresholding, with a trend towards underestimating nerve fiber area using auto-thresholding when higher proportions of nerve fibers were present. In conclusion, four weeks after superficial corneal injury, there is differential recovery of epithelial nerve axons; SBNP sum length is reduced, however the sum length of SNTs is similar to naïve eyes. Care should be taken when selecting image analysis methods to compare nerve parameters in different depths of the corneal epithelium due to differences in background autofluorescence. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. The morphological substrate for Renal Denervation: Nerve distribution patterns and parasympathetic nerves. A post-mortem histological study.

    Science.gov (United States)

    van Amsterdam, Wouter A C; Blankestijn, Peter J; Goldschmeding, Roel; Bleys, Ronald L A W

    2016-03-01

    Renal Denervation as a possible treatment for hypertension has been studied extensively, but knowledge on the distribution of nerves surrounding the renal artery is still incomplete. While sympathetic and sensory nerves have been demonstrated, there is no mention of the presence of parasympathetic nerve fibers. To provide a description of the distribution patterns of the renal nerves in man, and, in addition, provide a detailed representation of the relative contribution of the sympathetic, parasympathetic and afferent divisions of the autonomic nervous system. Renal arteries of human cadavers were each divided into four longitudinal segments and immunohistochemically stained with specific markers for afferent, parasympathetic and sympathetic nerves. Nerve fibers were semi-automatically quantified by computerized image analysis, and expressed as cross-sectional area relative to the distance to the lumen. A total of 3372 nerve segments were identified in 8 arteries of 7 cadavers. Sympathetic, parasympathetic and afferent nerves contributed for 73.5% (95% CI: 65.4-81.5%), 17.9% (10.7-25.1%) and 8.7% (5.0-12.3%) of the total cross-sectional nerve area, respectively. Nerves are closer to the lumen in more distal segments and larger bundles that presumably innervate the kidney lie at 1-3.5mm distance from the lumen. The tissue-penetration depth of the ablation required to destroy 50% of the nerve fibers is 2.37 mm in the proximal segment and 1.78 mm in the most distal segments. Sympathetic, parasympathetic and afferent nerves exist in the vicinity of the renal artery. The results warrant further investigation of the role of the parasympathetic nervous system on renal physiology, and may contribute to refinement of the procedure by focusing the ablation on the most distal segment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  20. Antisites and anisotropic diffusion in GaAs and GaSb

    KAUST Repository

    Tahini, H. A.; Bracht, H.; Chroneos, Alexander; Grimes, R. W.; Murphy, S. T.; Schwingenschlö gl, Udo

    2013-01-01

    The significant diffusion of Ga under Ga-rich conditions in GaAs and GaSb is counter intuitive as the concentration of Ga vacancies should be depressed although Ga vacancies are necessary to interpret the experimental evidence for Ga transport

  1. Evaluation of glycated albumin (GA) and GA/HbA1c ratio for diagnosis of diabetes and glycemic control: A comprehensive review.

    Science.gov (United States)

    Yazdanpanah, Sara; Rabiee, Mohammad; Tahriri, Mohammadreza; Abdolrahim, Mojgan; Rajab, Asadollah; Jazayeri, Hossein E; Tayebi, Lobat

    2017-06-01

    Diabetes Mellitus (DM) is a group of metabolic diseases characterized by chronic high blood glucose concentrations (hyperglycemia). When it is left untreated or improperly managed, it can lead to acute complications including diabetic ketoacidosis and non-ketotic hyperosmolar coma. In addition, possible long-term complications include impotence, nerve damage, stroke, chronic kidney failure, cardiovascular disease, foot ulcers, and retinopathy. Historically, universal methods to measure glycemic control for the diagnosis of diabetes included fasting plasma glucose level (FPG), 2-h plasma glucose (2HP), and random plasma glucose. However, these measurements did not provide information about glycemic control over a long period of time. To address this problem, there has been a switch in the past decade to diagnosing diabetes and its severity through measurement of blood glycated proteins such as Hemoglobin A1c (HbA1c) and glycated albumin (GA). Diagnosis and evaluation of diabetes using glycated proteins has many advantages including high accuracy of glycemic control over a period of time. Currently, common laboratory methods used to measure glycated proteins are high-performance liquid chromatography (HPLC), immunoassay, and electrophoresis. HbA1c is one of the most important diagnostic factors for diabetes. However, some reports indicate that HbA1c is not a suitable marker to determine glycemic control in all diabetic patients. GA, which is not influenced by changes in the lifespan of erythrocytes, is thought to be a good alternative indicator of glycemic control in diabetic patients. Here, we review the literature that has investigated the suitability of HbA1c, GA and GA:HbA1c as indicators of long-term glycemic control and demonstrate the importance of selecting the appropriate glycated protein based on the patient's health status in order to provide useful and modern point-of-care monitoring and treatment.

  2. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection

    Directory of Open Access Journals (Sweden)

    Sara Pourshahidi

    2008-04-01

    Full Text Available

    Background and aims. Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections.

    Materials and methods. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test.

    Results. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127 and between right and left injection sites (P = 0.778.

    Conclusion. According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  3. Immediate Nerve Transfer for Treatment of Peroneal Nerve Palsy Secondary to an Intraneural Ganglion: Case Report and Review.

    Science.gov (United States)

    Ratanshi, Imran; Clark, Tod A; Giuffre, Jennifer L

    2018-05-01

    Intraneural ganglion cysts, which occur within the common peroneal nerve, are a rare cause of foot drop. The current standard of treatment for intraneural ganglion cysts involving the common peroneal nerve involves (1) cyst decompression and (2) ligation of the articular nerve branch to prevent recurrence. Nerve transfers are a time-dependent strategy for recovering ankle dorsiflexion in cases of high peroneal nerve palsy; however, this modality has not been performed for intraneural ganglion cysts involving the common peroneal nerve. We present a case of common peroneal nerve palsy secondary to an intraneural ganglion cyst occurring in a 74-year-old female. The patient presented with a 5-month history of pain in the right common peroneal nerve distribution and foot drop. The patient underwent simultaneous cyst decompression, articular nerve branch ligation, and nerve transfer of the motor branch to flexor hallucis longus to a motor branch of anterior tibialis muscle. At final follow-up, the patient demonstrated complete (M4+) return of ankle dorsiflexion, no pain, no evidence of recurrence and was able to bear weight without the need for orthotic support. Given the minimal donor site morbidity and recovery of ankle dorsiflexion, this report underscores the importance of considering early nerve transfers in cases of high peroneal neuropathy due to an intraneural ganglion cyst.

  4. Peripheral nerve conduits: technology update

    Science.gov (United States)

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  5. Distal median nerve dysfunction

    Science.gov (United States)

    ... later on. Inflammation of the tendons ( tendonitis ) or joints ( arthritis ) can also put pressure on the nerve. ... how fast electrical signals move through a nerve Neuromuscular ultrasound to view problems with the muscles and ...

  6. Effects of graded mechanical compression of rabbit sciatic nerve on nerve blood flow and electrophysiological properties.

    Science.gov (United States)

    Yayama, Takafumi; Kobayashi, Shigeru; Nakanishi, Yoshitaka; Uchida, Kenzo; Kokubo, Yasuo; Miyazaki, Tsuyoshi; Takeno, Kenichi; Awara, Kosuke; Mwaka, Erisa S; Iwamoto, Yukihide; Baba, Hisatoshi

    2010-04-01

    Entrapment neuropathy is a frequent clinical problem that can be caused by, among other factors, mechanical compression; however, exactly how a compressive force affects the peripheral nerves remains poorly understood. In this study, using a rabbit model of sciatic nerve injury (n=12), we evaluated the time-course of changes in intraneural blood flow, compound nerve action potentials, and functioning of the blood-nerve barrier during graded mechanical compression. Nerve injury was applied using a compressor equipped with a custom-made pressure transducer. Cessation of intraneural blood flow was noted at a mean compressive force of 0.457+/-0.022 N (+/-SEM), and the compound action potential became zero at 0.486+/-0.031 N. Marked extravasation of Evans blue albumin was noted after 20 min of intraneural ischemia. The functional changes induced by compression are likely due to intraneural edema, which could subsequently result in impairment of nerve function. These changes may be critical factors in the development of symptoms associated with nerve compression. (c) 2009 Elsevier Ltd. All rights reserved.

  7. Photoluminescence characterization of GaAs/GaAs0.64P0.19Sb0.17/GaAs heterostructure

    International Nuclear Information System (INIS)

    Chen, J.Y.; Chen, B.H.; Huang, Y.S.; Chin, Y.C.; Tsai, H.S.; Lin, H.H.; Tiong, K.K.

    2013-01-01

    Interfacial characteristics of GaAs/GaAs 0.64 P 0.19 Sb 0.17 GaAs heterostructures and emission properties of a quaternary GaAs 0.64 P 0.19 Sb 0.17 layer were studied by excitation-power- and temperature-dependent photoluminescence (PL) measurements. The GaAs-to-GaAsPSb upper interface related emission feature and signals from GaAsPSb and GaAs were observed and characterized. The upper interface related emission peak was attributed to the radiative recombination of spatially separated electron–hole pairs and suggesting the type-II alignment at the GaAs/GaAsPSb interface. The localized excitonic emission feature of GaAsPSb revealed a blueshift due to the saturation effect of localized states and showed a fast thermal-quench with the increase of temperature. The temperature variation of the band edge emission signal of GaAsPSb was found to follow that of GaAs closely. -- Highlights: ► PL characterization of GaAs/GaAsPSb/GaAs heterostructure. ► Type-II alignment at the GaAs/GaAsPSb interface. ► Near-band-edge emission lines of GaAsPSb

  8. GaN-based ultraviolet light-emitting diodes with AlN/GaN/InGaN multiple quantum wells.

    Science.gov (United States)

    Chang, Hung-Ming; Lai, Wei-Chih; Chen, Wei-Shou; Chang, Shoou-Jinn

    2015-04-06

    We demonstrate indium gallium nitride/gallium nitride/aluminum nitride (AlN/GaN/InGaN) multi-quantum-well (MQW) ultraviolet (UV) light-emitting diodes (LEDs) to improve light output power. Similar to conventional UV LEDs with AlGaN/InGaN MQWs, UV LEDs with AlN/GaN/InGaN MQWs have forward voltages (V(f)'s) ranging from 3.21 V to 3.29 V at 350 mA. Each emission peak wavelength of AlN/GaN/InGaN MQW UV LEDs presents 350 mA output power greater than that of the corresponding emission peak wavelength of AlGaN/InGaN MQW UV LEDs. The light output power at 350mA of AlN/GaN/InGaN MQWs UV LEDs with 375 nm emission wavelength can reach around 26.7% light output power enhancement in magnitude compared to the AlGaN/InGaN MQWs UV LEDs with same emission wavelength. But 350mA light output power of AlN/GaN/InGaN MQWs UV LEDs with emission wavelength of 395nm could only have light output power enhancement of 2.43% in magnitude compared with the same emission wavelength AlGaN/InGaN MQWs UV LEDs. Moreover, AlN/GaN/InGaN MQWs present better InGaN thickness uniformity, well/barrier interface quality and less large size pits than AlGaN/InGaN MQWs, causing AlN/GaN/InGaN MQW UV LEDs to have less reverse leakage currents at -20 V. Furthermore, AlN/GaN/InGaN MQW UV LEDs have the 2-kV human body mode (HBM) electrostatic discharge (ESD) pass yield of 85%, which is 15% more than the 2-kV HBM ESD pass yield of AlGaN/InGaN MQW UV LEDs of 70%.

  9. Thoracoscopic phrenic nerve patch insulation to avoid phrenic nerve stimulation with cardiac resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Masatsugu Nozoe, MD, PhD

    2014-04-01

    Full Text Available A 76-year-old female was implanted with a cardiac resynchronization therapy (CRT device, with the left ventricular lead implanted through a transvenous approach. One day after implantation, diaphragmatic stimulation was observed when the patient was in the seated position, which could not be resolved by device reprogramming. We performed thoracoscopic phrenic nerve insulation using a Gore-Tex patch. The left phrenic nerve was carefully detached from the pericardial adipose tissue, and a Gore-Tex patch was inserted between the phrenic nerve and pericardium using a thoracoscopic technique. This approach represents a potential option for the management of uncontrollable phrenic nerve stimulation during CRT.

  10. Facial Nerve Paralysis due to a Pleomorphic Adenoma with the Imaging Characteristics of a Facial Nerve Schwannoma.

    Science.gov (United States)

    Nader, Marc-Elie; Bell, Diana; Sturgis, Erich M; Ginsberg, Lawrence E; Gidley, Paul W

    2014-08-01

    Background Facial nerve paralysis in a patient with a salivary gland mass usually denotes malignancy. However, facial paralysis can also be caused by benign salivary gland tumors. Methods We present a case of facial nerve paralysis due to a benign salivary gland tumor that had the imaging characteristics of an intraparotid facial nerve schwannoma. Results The patient presented to our clinic 4 years after the onset of facial nerve paralysis initially diagnosed as Bell palsy. Computed tomography demonstrated filling and erosion of the stylomastoid foramen with a mass on the facial nerve. Postoperative histopathology showed the presence of a pleomorphic adenoma. Facial paralysis was thought to be caused by extrinsic nerve compression. Conclusions This case illustrates the difficulty of accurate preoperative diagnosis of a parotid gland mass and reinforces the concept that facial nerve paralysis in the context of salivary gland tumors may not always indicate malignancy.

  11. Shot noise reduction in the AlGaAs/GaAs- and InGaP/GaAs-based HBTs

    Science.gov (United States)

    Sakalas, Paulius; Schroeter, Michael; Zampardi, Peter; Zirath, Herbert

    2003-05-01

    Noise parameters of AlGaAs/GaAs and InGaP/GaAs HBTs were measured in microwave frequency range and modeled using the small-signal equivalent circuit approach. Correlated current noise sources in the base and collector currents with thermal noise in the circuit resistive elements were accounted for by the model and yielded good agreement with the measured data. This enabled an extraction of the different noise source contributions to minimum noise figure (NFmin) in AlGaAs/GaAs and InGaP/GaAs HBTs. Decomposition of the (NFmin) in to the different contributors showed that the main noise sources in investigated HBTs are correlated base and collector current shot noise. The observed minimum of NFmin versus frequency at lower collector current is explained by the reduction of the emitter/base junction shot noise component due to the spike in the emitter/base junction and associated accumulation of the quasi-thermalized electrons forming a space charge, which screens the electron transfer through the barrier. The bias (VCE) increase creates an efficient electric field in collector/base junction, capable of 'washing out' the accumulated charge. Such shot noise reduction in HBTs could be exploited in the LNA for the RF application.

  12. Collision tumor of the facial nerve: a synchronous seventh nerve schwannoma and neurofibroma.

    Science.gov (United States)

    Gross, Brian C; Carlson, Matthew L; Driscoll, Colin L; Moore, Eric J

    2012-10-01

    To report a novel case of a collision tumor involving an intraparotid neurofibroma and a mastoid segment facial nerve schwannoma. Clinical capsule report. Tertiary academic referral center. A 29-year-old woman with a 2-year history of an asymptomatic enlarging left infraauricular mass and normal FN function presented to a tertiary care referral center. Computed tomography and magnetic resonance imaging demonstrated a cystic lesion in the deep portion of the parotid gland extending into the stylomastoid foramen. The patient underwent superficial parotidectomy, and a cystic parotid mass was found to be intrinsic to the intraparotid facial nerve. A portion of the mass was biopsied, and intraoperative frozen section pathology was consistent with a neurofibroma. A mastoidectomy with FN decompression was then performed until a normal-appearing segment was identified just proximal to the second genu. After biopsy, proximal facial nerve stimulation failed to elicit evoked motor potentials, and en bloc resection was performed. Final pathology demonstrated a schwannoma involving the mastoid segment and a neurofibroma involving the proximal intraparotid facial nerve. We report the first case of a facial nerve collision tumor involving an intraparotid neurofibroma and a mastoid segment facial nerve schwannoma. Benign FN sheath tumors of the parotid gland are rare but should be considered in the differential diagnosis of a parotid mass.

  13. Reconstruction of facial nerve injuries in children.

    Science.gov (United States)

    Fattah, Adel; Borschel, Gregory H; Zuker, Ron M

    2011-05-01

    Facial nerve trauma is uncommon in children, and many spontaneously recover some function; nonetheless, loss of facial nerve activity leads to functional impairment of ocular and oral sphincters and nasal orifice. In many cases, the impediment posed by facial asymmetry and reduced mimetic function more significantly affects the child's psychosocial interactions. As such, reconstruction of the facial nerve affords great benefits in quality of life. The therapeutic strategy is dependent on numerous factors, including the cause of facial nerve injury, the deficit, the prognosis for recovery, and the time elapsed since the injury. The options for treatment include a diverse range of surgical techniques including static lifts and slings, nerve repairs, nerve grafts and nerve transfers, regional, and microvascular free muscle transfer. We review our strategies for addressing facial nerve injuries in children.

  14. A prospective clinical evaluation of biodegradable neurolac nerve guides for sensory nerve repair in the hand

    NARCIS (Netherlands)

    Bertleff, MJOE; Meek, MF; Nicolai, JPA

    Purpose: Our purpose was to study the recovery of sensory nerve function, after treatment of traumatic peripheral nerve lesions with a biodegradable poly(DL-lactide-ε-caprolactone) Neurolac nerve guide (Polyganics B.V., Groningen, the Netherlands) versus the current standard reconstruction

  15. The Cranial Nerve Skywalk: A 3D Tutorial of Cranial Nerves in a Virtual Platform

    Science.gov (United States)

    Richardson-Hatcher, April; Hazzard, Matthew; Ramirez-Yanez, German

    2014-01-01

    Visualization of the complex courses of the cranial nerves by students in the health-related professions is challenging through either diagrams in books or plastic models in the gross laboratory. Furthermore, dissection of the cranial nerves in the gross laboratory is an extremely meticulous task. Teaching and learning the cranial nerve pathways…

  16. The enlargement of geniculate fossa of facial nerve canal: a new CT finding of facial nerve canal fracture

    International Nuclear Information System (INIS)

    Gong Ruozhen; Li Yuhua; Gong Wuxian; Wu Lebin

    2006-01-01

    Objective: To discuss the value of enlargement of geniculate fossa of facial nerve canal in the diagnosis of facial nerve canal fracture. Methods: Thirty patients with facial nerve canal fracture underwent axial and coronal CT scan. The correlation between the fracture and the enlargement of geniculate fossa of facial nerve canal was analyzed. The ability of showing the fracture and enlargement of geniculate fossa of facial nerve canal in axial and coronal imaging were compared. Results: Fracture of geniculate fossa of facial nerve canal was found in the operation in 30 patients, while the fracture was detected in CT in 18 patients. Enlargement of geniculate ganglion of facial nerve was detected in 30 patients in the operation, while the enlargement of fossa was found in CT in 28 cases. Enlargement and fracture of geniculate fossa of facial nerve canal were both detected in CT images in 18 patients. Only the enlargement of geniculate fossa of facial nerve canal was shown in 12 patients in CT. Conclusion: Enlargement of geniculate fossa of facial nerve canal was a useful finding in the diagnosis of fracture of geniculate fossa in patients with facial paralysis, even no fracture line was shown on CT images. (authors)

  17. Side Effects: Nerve Problems (Peripheral Neuropathy)

    Science.gov (United States)

    Nerve problems, such as peripheral neuropathy, can be caused by cancer treatment. Learn about signs and symptoms of nerve changes. Find out how to prevent or manage nerve problems during cancer treatment.

  18. Hydrogel derived from porcine decellularized nerve tissue as a promising biomaterial for repairing peripheral nerve defects.

    Science.gov (United States)

    Lin, Tao; Liu, Sheng; Chen, Shihao; Qiu, Shuai; Rao, Zilong; Liu, Jianghui; Zhu, Shuang; Yan, Liwei; Mao, Haiquan; Zhu, Qingtang; Quan, Daping; Liu, Xiaolin

    2018-06-01

    Decellularized matrix hydrogels derived from tissues or organs have been used for tissue repair due to their biocompatibility, tunability, and tissue-specific extracellular matrix (ECM) components. However, the preparation of decellularized peripheral nerve matrix hydrogels and their use to repair nerve defects have not been reported. Here, we developed a hydrogel from porcine decellularized nerve matrix (pDNM-G), which was confirmed to have minimal DNA content and retain collagen and glycosaminoglycans content, thereby allowing gelatinization. The pDNM-G exhibited a nanofibrous structure similar to that of natural ECM, and a ∼280-Pa storage modulus at 10 mg/mL similar to that of native neural tissues. Western blot and liquid chromatography tandem mass spectrometry analysis revealed that the pDNM-G consisted mostly of ECM proteins and contained primary ECM-related proteins, including fibronectin and collagen I and IV). In vitro experiments showed that pDNM-G supported Schwann cell proliferation and preserved cell morphology. Additionally, in a 15-mm rat sciatic nerve defect model, pDNM-G was combined with electrospun poly(lactic-acid)-co-poly(trimethylene-carbonate)conduits to bridge the defect, which did not elicit an adverse immune response and promoted the activation of M2 macrophages associated with a constructive remodeling response. Morphological analyses and electrophysiological and functional examinations revealed that the regenerative outcomes achieved by pDNM-G were superior to those by empty conduits and closed to those using rat decellularized nerve matrix allograft scaffolds. These findings indicated that pDNM-G, with its preserved ECM composition and nanofibrous structure, represents a promising biomaterial for peripheral nerve regeneration. Decellularized nerve allografts have been widely used to treat peripheral nerve injury. However, given their limited availability and lack of bioactive factors, efforts have been made to improve the efficacy

  19. Human vagus nerve branching in the cervical region.

    Directory of Open Access Journals (Sweden)

    Niels Hammer

    Full Text Available Vagus nerve stimulation is increasingly applied to treat epilepsy, psychiatric conditions and potentially chronic heart failure. After implanting vagus nerve electrodes to the cervical vagus nerve, side effects such as voice alterations and dyspnea or missing therapeutic effects are observed at different frequencies. Cervical vagus nerve branching might partly be responsible for these effects. However, vagus nerve branching has not yet been described in the context of vagus nerve stimulation.Branching of the cervical vagus nerve was investigated macroscopically in 35 body donors (66 cervical sides in the carotid sheath. After X-ray imaging for determining the vertebral levels of cervical vagus nerve branching, samples were removed to confirm histologically the nerve and to calculate cervical vagus nerve diameters and cross-sections.Cervical vagus nerve branching was observed in 29% of all cases (26% unilaterally, 3% bilaterally and proven histologically in all cases. Right-sided branching (22% was more common than left-sided branching (12% and occurred on the level of the fourth and fifth vertebra on the left and on the level of the second to fifth vertebra on the right side. Vagus nerves without branching were significantly larger than vagus nerves with branches, concerning their diameters (4.79 mm vs. 3.78 mm and cross-sections (7.24 mm2 vs. 5.28 mm2.Cervical vagus nerve branching is considerably more frequent than described previously. The side-dependent differences of vagus nerve branching may be linked to the asymmetric effects of the vagus nerve. Cervical vagus nerve branching should be taken into account when identifying main trunk of the vagus nerve for implanting electrodes to minimize potential side effects or lacking therapeutic benefits of vagus nerve stimulation.

  20. Nerve growth factor loaded heparin/chitosan scaffolds for accelerating peripheral nerve regeneration.

    Science.gov (United States)

    Li, Guicai; Xiao, Qinzhi; Zhang, Luzhong; Zhao, Yahong; Yang, Yumin

    2017-09-01

    Artificial chitosan scaffolds have been widely investigated for peripheral nerve regeneration. However, the effect was not as good as that of autologous grafts and therefore could not meet the clinical requirement. In the present study, the nerve growth factor (NGF) loaded heparin/chitosan scaffolds were fabricated via electrostatic interaction for further improving nerve regeneration. The physicochemical properties including morphology, wettability and composition were measured. The heparin immobilization, NGF loading and release were quantitatively and qualitatively characterized, respectively. The effect of NGF loaded heparin/chitosan scaffolds on nerve regeneration was evaluated by Schwann cells culture for different periods. The results showed that the heparin immobilization and NGF loading did not cause the change of bulk properties of chitosan scaffolds except for morphology and wettability. The pre-immobilization of heparin in chitosan scaffolds could enhance the stability of subsequently loaded NGF. The NGF loaded heparin/chitosan scaffolds could obviously improve the attachment and proliferation of Schwann cells in vitro. More importantly, the NGF loaded heparin/chitosan scaffolds could effectively promote the morphology development of Schwann cells. The study may provide a useful experimental basis to design and develop artificial implants for peripheral nerve regeneration and other tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. General anesthesia plus ilioinguinal nerve block versus spinal anesthesia for ambulatory inguinal herniorrhapy

    Directory of Open Access Journals (Sweden)

    Lucía Vizcaíno-Martínez

    2014-01-01

    Full Text Available Objective: The aim was to evaluate general anesthesia (GA plus ilioinguinal nerve block (IIB versus spinal anesthesia (SA in patients scheduled for ambulatory inguinal hernia repair regarding pain management, anesthesia recovery and reducing potential complications. Materials and Methods: A double-blind, prospective, randomized, controlled study in patients American Society of Anesthesiologists I-III randomized into two groups: GA plus IIB group, induction of anesthesia with propofol, maintenance with sevoflurane, airway management with laryngeal mask allowing spontaneous ventilation and ultrasound-guided IIB; SA group, patients who underwent spinal block with 2% mepivacaine. The study variables were pain intensity, assessed by visual analog scale, analgesic requirements until hospital discharge, time to ambulation and discharge, postoperative complications-related to both techniques and satisfaction experienced. Results: Thirty-two patients were enrolled; 16 patients in each group. The differences regarding pain were statistically significant at 2 h of admission (P < 0.001 and at discharge (P < 0.001 in favor of the GA plus ilioinguinal block group. In addition in this group, analgesic requirements were lower than SA group (P < 0.001, with times of ambulation and discharge significantly shorter. The SA group had a higher tendency to develop complications and less satisfaction. Conclusion: General anesthesia plus IIB is better than SA regarding postoperative analgesia, time to mobilization and discharge, side-effect profile and satisfaction experienced by the patients.

  2. High breakdown voltage in AlGaN/GaN HEMTs using AlGaN/GaN/AlGaN quantum-well electron-blocking layers.

    Science.gov (United States)

    Lee, Ya-Ju; Yao, Yung-Chi; Huang, Chun-Ying; Lin, Tai-Yuan; Cheng, Li-Lien; Liu, Ching-Yun; Wang, Mei-Tan; Hwang, Jung-Min

    2014-01-01

    In this paper, we numerically study an enhancement of breakdown voltage in AlGaN/GaN high-electron-mobility transistors (HEMTs) by using the AlGaN/GaN/AlGaN quantum-well (QW) electron-blocking layer (EBL) structure. This concept is based on the superior confinement of two-dimensional electron gases (2-DEGs) provided by the QW EBL, resulting in a significant improvement of breakdown voltage and a remarkable suppression of spilling electrons. The electron mobility of 2-DEG is hence enhanced as well. The dependence of thickness and composition of QW EBL on the device breakdown is also evaluated and discussed.

  3. [Morphologic changes during neuroplastic nerve restoration].

    Science.gov (United States)

    Bakalski, E P; Rozhkov, E N

    1976-06-01

    The dynamics of ultrastructural changes in plastic recovery of the function of the additional nerve by the anterior branch of the second cervical nerve was studied. The nerve cells at the level of the donor-nerve were found to be highly reactive and plastic. It was established that in the process of heterogenic regeneration of the nerve the most substantial changes in neuronal structures were observed during the first two months. The cysterns of the endoplasmic network remained dilated for a long time after platic operation with might be related with the increased protein metabolism in the neuron.

  4. Degeneration and regeneration of motor and sensory nerves: a stereological study of crush lesions in rat facial and mental nerves

    DEFF Research Database (Denmark)

    Barghash, Ziad; Larsen, Jytte Overgaard; Al-Bishri, Awad

    2013-01-01

    The aim of this study was to evaluate the degeneration and regeneration of a sensory nerve and a motor nerve at the histological level after a crush injury. Twenty-five female Wistar rats had their mental nerve and the buccal branch of their facial nerve compressed unilaterally against a glass rod...... for 30 s. Specimens of the compressed nerves and the corresponding control nerves were dissected at 3, 7, and 19 days after surgery. Nerve cross-sections were stained with osmium tetroxide and toluidine blue and analysed using two-dimensional stereology. We found differences between the two nerves both...... in the normal anatomy and in the regenerative pattern. The mental nerve had a larger cross-sectional area including all tissue components. The mental nerve had a larger volume fraction of myelinated axons and a correspondingly smaller volume fraction of endoneurium. No differences were observed...

  5. The Impact of the Tobin Tax in a Heterogeneous Agent Model of the Foreign Exchange Market

    Czech Academy of Sciences Publication Activity Database

    Staněk, F.; Kukačka, Jiří

    2018-01-01

    Roč. 51, č. 4 (2018), s. 865-892 ISSN 0927-7099 R&D Projects: GA ČR(CZ) GBP402/12/G097 Grant - others:GA UK(CZ) 588912; GA MŠk(CZ) SVV260233 Institutional support: RVO:67985556 Keywords : Tobin tax * Foreign exchange market * Agent-based modeling * Walrasian auctioneer Subject RIV: AH - Economic s OBOR OECD: Applied Economic s, Econometrics Impact factor: 1.053, year: 2016 http://library.utia.cas.cz/separaty/2017/E/kukacka-0472380.pdf

  6. Single vial kit formulation for preparation of {sup 68}Ga-AMBA: a PET imaging agent for prostate cancers

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Usha; Mukherjee, Archana; Gamre, Naresh; Dash, Ashutosh [Isotope Applications and Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai (India); Sarma, Haladhar Dev [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-05-01

    This work was aimed at the kit formulation of a bombesin analog, AMBA, for potential use in imaging of prostate cancers after {sup 68}Ga labeling. Towards this aim, a kit was formulated in acetate buffer under aseptic conditions for labeling with {sup 68}Ga eluted from the nanoceria-PAN based {sup 68}Ge/{sup 68}Ga BARC generator. All the reaction parameters for optimum radiolabeling were standardized and the radiometal complexes were characterized by chromatography techniques. The kit formulations gave >95% radiolabeling yields consistently when tested up to two months. Pharmacokinetics of the radiolabeled peptide was studied in Swiss mice, which showed fast clearance of activity via renal route. (author)

  7. Self-consistent simulation of carrier confinement characteristics in (AlyGa1−yN/AlN)SLs/GaN/(InxGa1−xN/GaN)MQW/GaN heterostructures

    International Nuclear Information System (INIS)

    Ding Jieqin; Wang Xiaoliang; Xiao Hongling; Wang Cuimei; Yin Haibo; Chen Hong; Feng Chun; Jiang Lijuan

    2012-01-01

    Highlights: ► We present calculations of carrier confinement characteristics. ► An optimization of In x Ga 1−x N/GaN multiquantum-well (MQW) was made. ► 2DEG sheet carrier density in designed heterostructure is greatly increased. ► Interface roughness and alloy disorder scattering reduced. ► Carrier mobility will be improved in designed heterostructure. - Abstract: We present calculations of carrier confinement characteristics in (Al y Ga 1−y N/AlN)SLs/GaN/(In x Ga 1−x N/GaN)MQW/GaN heterojunction structure in the presence of spontaneous and piezoelectrically induced polarization effects. The calculations were made using a self-consistent solution of the Schrödinger, Poisson, potential and charge balance equations. An optimization of In x Ga 1−x N/GaN multiquantum-well (MQW) was made firstly including thickness of GaN channel, InGaN, and indium composition of In x Ga 1−x N in order to increase carrier density and mobility, and the influence of pairs of AlGaN/AlN superlattices (SLs) and InGaN/GaN MQWs on structure was discussed. Theoretical calculations clearly indicate that the two-dimensional electron gas (2DEG) sheet carrier density in designed heterostructure is greatly increased due to the enhancing of carrier confinement compared to those in conventional AlGaN/GaN one at the similar Al composition. Furthermore, the calculated carrier distribution shows that carrier mobility will be improved by reducing interface roughness and alloy disorder scattering in designed heterostructure.

  8. AlGaN/GaN double-channel HEMT

    International Nuclear Information System (INIS)

    Quan Si; Hao Yue; Ma Xiaohua; Zheng Pengtian; Xie Yuanbin

    2010-01-01

    The fabrication of AlGaN/GaN double-channel high electron mobility transistors on sapphire substrates is reported. Two carrier channels are formed in an AlGaN/GaN/AlGaN/GaN multilayer structure. The DC performance of the resulting double-channel HEMT shows a wider high transconductance region compared with single-channel HEMT. Simulations provide an explanation for the influence of the double-channel on the high transconductance region. The buffer trap is suggested to be related to the wide region of high transconductance. The RF characteristics are also studied. (semiconductor devices)

  9. [Isolated traumatic injuries of the axillary nerve. Radial nerve transfer in four cases and literatura review].

    Science.gov (United States)

    Domínguez-Páez, Miguel; Socolovsky, Mariano; Di Masi, Gilda; Arráez-Sánchez, Miguel Ángel

    2012-11-01

    To analyze the results of an initial series of four cases of traumatic injuries of the axillary nerve, treated by a nerve transfer from the triceps long branch of the radial nerve. An extensive analysis of the literature has also been made. Four patients aged between 21 and 42 years old presenting an isolated traumatic palsy of the axillary nerve were operated between January 2007 and June 2010. All cases were treated by nerve transfer six to eight months after the trauma. The results of these cases are analyzed, the same as the axillary nerve injuries series presented in the literature from 1982. One year after the surgery, all patients improved their abduction a mean of 70° (range 30 to 120°), showing a M4 in the British Medical Council Scale. No patient complained of triceps weakness after the procedure. These results are similar to those published employing primary grafting for the axillary nerve. Isolated injuries of the axillary nerve should be treated with surgery when spontaneous recovery is not verified 6 months after the trauma. Primary repair with grafts is the most popular surgical technique, with a rate of success of approximately 90%. The preliminary results of a nerve transfer employing the long triceps branch are similar, and a definite comparison of both techniques with a bigger number of cases should be done in the future. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  10. Radial nerve dysfunction (image)

    Science.gov (United States)

    The radial nerve travels down the arm and supplies movement to the triceps muscle at the back of the upper arm. ... the wrist and hand. The usual causes of nerve dysfunction are direct trauma, prolonged pressure on the ...

  11. Antisites and anisotropic diffusion in GaAs and GaSb

    KAUST Repository

    Tahini, H. A.

    2013-10-02

    The significant diffusion of Ga under Ga-rich conditions in GaAs and GaSb is counter intuitive as the concentration of Ga vacancies should be depressed although Ga vacancies are necessary to interpret the experimental evidence for Ga transport. To reconcile the existence of Ga vacancies under Ga-rich conditions, transformation reactions have been proposed. Here, density functional theory is employed to calculate the formation energies of vacancies on both sublattices and the migration energy barriers to overcome the formation of the vacancy-antisite defect. Transformation reactions enhance the vacancy concentration in both materials and migration energy barriers indicate that Ga vacancies will dominate.

  12. Changes in the blood-nerve barrier after sciatic nerve cold injury: indications supporting early treatment

    Directory of Open Access Journals (Sweden)

    Hao Li

    2015-01-01

    Full Text Available Severe edema in the endoneurium can occur after non-freezing cold injury to the peripheral nerve, which suggests damage to the blood-nerve barrier. To determine the effects of cold injury on the blood-nerve barrier, the sciatic nerve on one side of Wistar rats was treated with low temperatures (3-5°C for 2 hours. The contralateral sciatic nerve was used as a control. We assessed changes in the nerves using Evans blue as a fluid tracer and morphological methods. Excess fluid was found in the endoneurium 1 day after cold injury, though the tight junctions between cells remained closed. From 3 to 5 days after the cold injury, the fluid was still present, but the tight junctions were open. Less tracer leakage was found from 3 to 5 days after the cold injury compared with 1 day after injury. The cold injury resulted in a breakdown of the blood-nerve barrier function, which caused endoneurial edema. However, during the early period, the breakdown of the blood-nerve barrier did not include the opening of tight junctions, but was due to other factors. Excessive fluid volume produced a large increase in the endoneurial fluid pressure, prevented liquid penetration into the endoneurium from the microvasculature. These results suggest that drug treatment to patients with cold injuries should be administered during the early period after injury because it may be more difficult for the drug to reach the injury site through the microcirculation after the tissue fluid pressure becomes elevated.

  13. Comparison of Nerve Excitability Testing, Nerve Conduction Velocity, and Behavioral Observations for Acrylamide Induced Peripheral Neuropathy

    Science.gov (United States)

    Nerve excitability (NE) testing is a sensitive method to test for peripheral neurotoxicity in humans,and may be more sensitive than compound nerve action potential (CNAP) or nerve conduction velocity (NCV).We used acrylamide to compare the NE and CNAP/NCV methods. Behavioral test...

  14. Treatment with acetyl-L-carnitine exerts a neuroprotective effect in the sciatic nerve following loose ligation: a functional and microanatomical study

    Directory of Open Access Journals (Sweden)

    Daniele Tomassoni

    2018-01-01

    Full Text Available Peripheral neuropathies are chronic painful syndromes characterized by allodynia, hyperalgesia and altered nerve functionality. Nerve tissue degeneration represents the microanatomical correlate of peripheral neuropathies. Aimed to improve the therapeutic possibilities, this study investigated the hypersensitivity and the neuromorphological alterations related to the loose ligation of the sciatic nerve in rats. Effects elicited by treatment with acetyl-L-carnitine (ALCAR in comparison to gabapentin were assessed. Axonal injury, reduction of myelin deposition and accumulation of inflammatory cells were detected in damaged nerve. A decrease of phosphorylated 200-kDa neurofilament (NFP immunoreactivity and a redistribution in small clusters of myelin basic like-protein (MBP were observed in ipsilateral nerves. Treatment with ALCAR (100 mg/kg intraperitoneally - i.p. and gabapentin (70 mg/kg i.p. administered bis in die for 14 days induced a significant pain relieving effect. ALCAR, but not gabapentin, significantly countered neuromorphological changes and increased axonal NFP immunoreactivity. These findings indicate that both ALCAR and gabapentin significantly decreased the hypersensitivity related to neuropathic lesions. The observation of the positive ALCAR effect on axonal and myelin sheath alterations in damaged nerve supports its use as neurorestorative agent against neuropathies through mechanism(s consistent to those focused in this study.

  15. AlGaN nanocolumns and AlGaN/GaN/AlGaN nanostructures grown by molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Ristic, J.; Sanchez-Garcia, M.A.; Ulloa, J.M.; Calleja, E. [Departamento de Ingenieria Electronica, ETSI Telecomunicacion, Universidad Politecnica de Madrid, Ciudad Universitaria, 28040 Madrid (Spain); Sanchez-Paramo, J.; Calleja, J.M. [Departamento de Fisica de Materiales, Universidad Autonoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Jahn, U.; Trampert, A.; Ploog, K.H. [Paul-Drude-Institut fuer Festkoerperelektronik, Hausvogteiplatz 5-7, 10117 Berlin (Germany)

    2002-12-01

    This work reports on the characterization of hexagonal, single crystal AlGaN nanocolumns with diameters in the range of 30 to 100 nm grown by molecular beam epitaxy on Si(111) substrates. The change of the flux ratio between the Al and the total III-element controls the alloy composition. The Al composition trend versus the Al flux is consistent both with the E{sub 2} phonon energy values measured by inelastic light scattering and the luminescence emission peaks position. High quality low dimensional AlGaN/GaN/AlGaN heterostructures with five GaN quantum discs, 2 and 4 nm thick, embedded into the AlGaN columns, were designed in order to study the quantum confinement effects. (Abstract Copyright [2002], Wiley Periodicals, Inc.)

  16. 3D printing strategies for peripheral nerve regeneration.

    Science.gov (United States)

    Petcu, Eugen B; Midha, Rajiv; McColl, Erin; Popa-Wagner, Aurel; Chirila, Traian V; Dalton, Paul D

    2018-03-23

    After many decades of biomaterials research for peripheral nerve regeneration, a clinical product (the nerve guide), is emerging as a proven alternative for relatively short injury gaps. This review identifies aspects where 3D printing can assist in improving long-distance nerve guide regeneration strategies. These include (1) 3D printing of the customizable nerve guides, (2) fabrication of scaffolds that fill nerve guides, (3) 3D bioprinting of cells within a matrix/bioink into the nerve guide lumen and the (4) establishment of growth factor gradients along the length a nerve guide. The improving resolution of 3D printing technologies will be an important factor for peripheral nerve regeneration, as fascicular-like guiding structures provide one path to improved nerve guidance. The capability of 3D printing to manufacture complex structures from patient data based on existing medical imaging technologies is an exciting aspect that could eventually be applied to treating peripheral nerve injury. Ultimately, the goal of 3D printing in peripheral nerve regeneration is the automated fabrication, potentially customized for the patient, of structures within the nerve guide that significantly outperform the nerve autograft over large gap injuries.

  17. IDENTIFICATION OF DEGRADATION PRODUCTS OF SOME CHEMICAL WARFARE AGENTS BY CAPILLARY ELECTROPHORESIS IONSPRAY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    KOSTIAINEN, R; BRUINS, AP; HAKKINEN, VMA

    1993-01-01

    Capillary zone electrophoresis-ionspray mass spectrometry (CZE-IS-MS) in the negative-ion mode was applied in the identification of five organophosphonic acids, which are the primary hydrolysis products of nerve agents. The spectra exhibit a very abundant (M - H)- ion with minimal fragmentation.

  18. Evaluation of functional nerve recovery after reconstruction with a new biodegradable poly (DL-lactide-epsilon-caprolactone) nerve guide

    NARCIS (Netherlands)

    Meek, MF; denDunnen, WFA; Robinson, PH; Pennings, AJ; Schakenraad, JM

    The aim of this study was to evaluate functional nerve recovery following reconstruction of a 1 cm gap in the sciatic nerve of a rat, using a new biodegradable p (DLLA-epsilon-CL) nerve guide. To evaluate both motor and sensory nerve recovery, walking track analysis and electrostimulation tests were

  19. Effect of Organic Co-blowing Agents on the Morphology of CO2 Blown Microcellular Polystyrene Foams.

    Czech Academy of Sciences Publication Activity Database

    Nistor, A.; Topiař, Martin; Sovová, Helena; Kosek, J.

    2017-01-01

    Roč. 130, DEC 2017 (2017), s. 30-39 ISSN 0896-8446 R&D Projects: GA ČR(CZ) GA14-18938S Institutional support: RVO:67985858 Keywords : polystyrene * closed-cell microcellular foam * co-blowing agent Subject RIV: CI - Industrial Chemistry, Chemical Engineering OBOR OECD: Chemical process engineering Impact factor: 2.991, year: 2016

  20. Degeneration and regeneration of motor and sensory nerves: a stereological study of crush lesions in rat facial and mental nerves.

    Science.gov (United States)

    Barghash, Z; Larsen, J O; Al-Bishri, A; Kahnberg, K-E

    2013-12-01

    The aim of this study was to evaluate the degeneration and regeneration of a sensory nerve and a motor nerve at the histological level after a crush injury. Twenty-five female Wistar rats had their mental nerve and the buccal branch of their facial nerve compressed unilaterally against a glass rod for 30s. Specimens of the compressed nerves and the corresponding control nerves were dissected at 3, 7, and 19 days after surgery. Nerve cross-sections were stained with osmium tetroxide and toluidine blue and analysed using two-dimensional stereology. We found differences between the two nerves both in the normal anatomy and in the regenerative pattern. The mental nerve had a larger cross-sectional area including all tissue components. The mental nerve had a larger volume fraction of myelinated axons and a correspondingly smaller volume fraction of endoneurium. No differences were observed in the degenerative pattern; however, at day 19 the buccal branch had regenerated to the normal number of axons, whereas the mental nerve had only regained 50% of the normal number of axons. We conclude that the regenerative process is faster and/or more complete in the facial nerve (motor function) than it is in the mental nerve (somatosensory function). Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Outcome of different facial nerve reconstruction techniques

    OpenAIRE

    Mohamed, Aboshanif; Omi, Eigo; Honda, Kohei; Suzuki, Shinsuke; Ishikawa, Kazuo

    2016-01-01

    Abstract Introduction: There is no technique of facial nerve reconstruction that guarantees facial function recovery up to grade III. Objective: To evaluate the efficacy and safety of different facial nerve reconstruction techniques. Methods: Facial nerve reconstruction was performed in 22 patients (facial nerve interpositional graft in 11 patients and hypoglossal-facial nerve transfer in another 11 patients). All patients had facial function House-Brackmann (HB) grade VI, either caused by...

  2. Unilateral traumatic oculomotor nerve paralysis

    International Nuclear Information System (INIS)

    Asari, Syoji; Satoh, Toru; Yamamoto, Yuji

    1982-01-01

    The present authors report a case of unilateral traumatic oculomotor nerve paralysis which shows interesting CT findings which suggest its mechanism. A 60-year-old woman was admitted to our hospital with a cerebral concussion soon after a traffic accident. A CT scan was performed soon after admission. A high-density spot was noted at the medial aspect of the left cerebral peduncle, where the oculomotor nerve emerged from the midbrain, and an irregular, slender, high-density area was delineated in the right dorsolateral surface of the midbrain. Although the right hemiparesis had already improved by the next morning, the function of the left oculomotor nerve has been completely disturbed for the three months since the injury. In our case, it is speculated that an avulsion of the left oculomotor nerve rootlet occurred at the time of impact as the mechanism of the oculomotor nerve paralysis. A CT taken soon after the head injury showed a high-density spot; this was considered to be a hemorrhage occurring because of the avulsion of the nerve rootlet at the medial surface of the cerebral peduncle. (J.P.N.)

  3. Comparison of four different nerve conduction techniques of the superficial fibular sensory nerve.

    Science.gov (United States)

    Saffarian, Mathew R; Condie, Nathan C; Austin, Erica A; Mccausland, Katie E; Andary, Michael T; Sylvain, James R; Mull, Iian R; Zemper, Eric D; Jannausch, Mary L

    2017-09-01

    There are many different nerve conduction study (NCS) techniques to study the superficial fibular sensory nerve (SFSN). We present reference distal latency values and comparative data regarding 4 different NCS for the SFSN. Four different NCS techniques, Spartan technique, Izzo techniques (medial and intermediate dorsal cutaneous branches), and Daube technique, were performed on (114) healthy volunteers. A total of 108 subjects with 164 legs were included. The mean latency of the Spartan technique was longest (3.9 ± 0.3 ms) while the Daube technique was the shortest (3.6 ± 0.7 ms). The mean amplitude of the Daube technique displayed the highest (15.2 ± 8.2 μV) with the Spartan technique having the lowest (8.7 ± 4.2 μV). Among the absent sensory nerve action potentials (SNAPs), the Spartan technique was absent only twice (1.2%) and the Izzo Medial technique was absent more than the other techniques (2.9%). All 4 techniques were reliable methods for obtaining the superficial fibular nerve SNAP, present in 95% of individuals. Muscle Nerve 56: 458-462, 2017. © 2017 Wiley Periodicals, Inc.

  4. AlGaN/GaN HEMT structures on ammono bulk GaN substrate

    International Nuclear Information System (INIS)

    Kruszewski, P; Prystawko, P; Krysko, M; Smalc-Koziorowska, J; Leszczynski, M; Kasalynas, I; Nowakowska-Siwinska, A; Plesiewicz, J; Dwilinski, R; Zajac, M; Kucharski, R

    2014-01-01

    The work shows a successful fabrication of AlGaN/GaN high electron mobility transistor (HEMT) structures on the bulk GaN substrate grown by ammonothermal method providing an ultralow dislocation density of 10 4  cm −2  and wafers of size up to 2 inches in diameter. The AlGaN layers grown by metalorganic chemical vapor phase epitaxy method demonstrate atomically smooth surface, flat interfaces with reproduced low dislocation density as in the substrate. The test electronic devices—Schottky diodes and transistors—were designed without surface passivation and were successfully fabricated using mask-less laser-based photolithography procedures. The Schottky barrier devices demonstrate exceptionally low reverse currents smaller by a few orders of magnitude in comparison to the Schottky diodes made of AlGaN/GaN HEMT on sapphire substrate. (paper)

  5. Lentiviral-mediated transfer of CDNF promotes nerve regeneration and functional recovery after sciatic nerve injury in adult rats

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Lei; Liu, Yi; Zhao, Hua; Zhang, Wen; Guo, Ying-Jun; Nie, Lin, E-mail: chengleiyx@126.com

    2013-10-18

    Highlights: •CDNF was successfully transfected by a lentiviral vector into the distal sciatic nerve. •CDNF improved S-100, NF200 expression and nerve regeneration after sciatic injury. •CDNF improved the remyelination and thickness of the regenerated sciatic nerve. •CDNF improved gastrocnemius muscle weight and sciatic functional recovery. -- Abstract: Peripheral nerve injury is often followed by incomplete and unsatisfactory functional recovery and may be associated with sensory and motor impairment of the affected limb. Therefore, a novel method is needed to improve the speed of recovery and the final functional outcome after peripheral nerve injuries. This report investigates the effect of lentiviral-mediated transfer of conserved dopamine neurotrophic factor (CDNF) on regeneration of the rat peripheral nerve in a transection model in vivo. We observed notable overexpression of CDNF protein in the distal sciatic nerve after recombinant CDNF lentiviral vector application. We evaluated sciatic nerve regeneration after surgery using light and electron microscopy and the functional recovery using the sciatic functional index and target muscle weight. HE staining revealed better ordered structured in the CDNF-treated group at 8 weeks post-surgery. Quantitative analysis of immunohistochemistry of NF200 and S-100 in the CDNF group revealed significant improvement of axonal and Schwann cell regeneration compared with the control groups at 4 weeks and 8 weeks after injury. The thickness of the myelination around the axons in the CDNF group was significantly higher than in the control groups at 8 weeks post-surgery. The CDNF group displayed higher muscle weights and significantly increased sciatic nerve index values. Our findings suggest that CDNF gene therapy could provide durable and stable CDNF protein concentration and has the potential to enhance peripheral nerve regeneration, morphological and functional recovery following nerve injury, which suggests a

  6. Lentiviral-mediated transfer of CDNF promotes nerve regeneration and functional recovery after sciatic nerve injury in adult rats

    International Nuclear Information System (INIS)

    Cheng, Lei; Liu, Yi; Zhao, Hua; Zhang, Wen; Guo, Ying-Jun; Nie, Lin

    2013-01-01

    Highlights: •CDNF was successfully transfected by a lentiviral vector into the distal sciatic nerve. •CDNF improved S-100, NF200 expression and nerve regeneration after sciatic injury. •CDNF improved the remyelination and thickness of the regenerated sciatic nerve. •CDNF improved gastrocnemius muscle weight and sciatic functional recovery. -- Abstract: Peripheral nerve injury is often followed by incomplete and unsatisfactory functional recovery and may be associated with sensory and motor impairment of the affected limb. Therefore, a novel method is needed to improve the speed of recovery and the final functional outcome after peripheral nerve injuries. This report investigates the effect of lentiviral-mediated transfer of conserved dopamine neurotrophic factor (CDNF) on regeneration of the rat peripheral nerve in a transection model in vivo. We observed notable overexpression of CDNF protein in the distal sciatic nerve after recombinant CDNF lentiviral vector application. We evaluated sciatic nerve regeneration after surgery using light and electron microscopy and the functional recovery using the sciatic functional index and target muscle weight. HE staining revealed better ordered structured in the CDNF-treated group at 8 weeks post-surgery. Quantitative analysis of immunohistochemistry of NF200 and S-100 in the CDNF group revealed significant improvement of axonal and Schwann cell regeneration compared with the control groups at 4 weeks and 8 weeks after injury. The thickness of the myelination around the axons in the CDNF group was significantly higher than in the control groups at 8 weeks post-surgery. The CDNF group displayed higher muscle weights and significantly increased sciatic nerve index values. Our findings suggest that CDNF gene therapy could provide durable and stable CDNF protein concentration and has the potential to enhance peripheral nerve regeneration, morphological and functional recovery following nerve injury, which suggests a

  7. Behavioural breaks in the heterogeneous agent model: The impact of herding, overconfidence, and market sentiment

    Czech Academy of Sciences Publication Activity Database

    Kukačka, Jiří; Baruník, Jozef

    2013-01-01

    Roč. 392, č. 23 (2013), s. 5920-5938 ISSN 0378-4371 R&D Projects: GA ČR GA402/09/0965 Institutional support: RVO:67985556 Keywords : Heterogeneous agent model * Behavioural finance * Herding * Overconfidence * Market sentiment * Stock market crash Subject RIV: AH - Economics Impact factor: 1.722, year: 2013 http://library.utia.cas.cz/separaty/2013/E/barunik-0395344.pdf

  8. Stochastic nanopore sensors for the detection of terrorist agents: Current status and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Liu Aihua; Zhao Qitao [Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX 76019-0065 (United States); Guan Xiyun, E-mail: xguan@uta.edu [Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX 76019-0065 (United States)

    2010-08-24

    Nanopore stochastic sensor works by monitoring the ionic current modulations induced by the passage of analytes of interest through a single pore, which can be obtained from a biological ion channel by self-assembly or artificially fabricated in a solid-state membrane. In this minireview, we overview the use of biological nanopores and artificial nanopores for the detection of terrorist agents including explosives, organophosphorus nerve agents, nitrogen mustards, organoarsenic compounds, toxins, and viruses. We also discuss the current challenge in the development of deployable nanopore sensors for real-world applications.

  9. High-intensity facial nerve lesions on T2-weighted images in chronic persistent facial nerve palsy

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Dept. of Radiology, Tottori Univ. (Japan); Ishii, K. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Okitsu, T. [Dept. of Otolaryngology, Sendai City Hospital (Japan); Ogawa, T. [Dept. of Radiology, Tottori Univ. (Japan); Okudera, T. [Dept. of Radiology, Research Inst. of Brain and Blood Vessels-Akita, Akita (Japan)

    2001-05-01

    Our aim was to estimate the value of MRI in detecting irreversibly paralysed facial nerves. We examined 95 consecutive patients with a facial nerve palsy (14 with a persistent palsy, and 81 with good recovery), using a 1.0 T unit, with T2-weighted and contrast-enhanced T1-weighted images. The geniculate ganglion and tympanic segment had gave high signal on T2-weighted images in the chronic stage of persistent palsy, but not in acute palsy. The enhancement pattern of the facial nerve in the chronic persistent facial nerve palsy is similar to that in the acute palsy with good recovery. These findings suggest that T2-weighted MRI can be used to show severely damaged facial nerves. (orig.)

  10. Identification of chemical warfare agents from vapor samples using a field-portable capillary gas chromatography/membrane-interfaced electron ionization quadrupole mass spectrometry instrument with Tri-Bed concentrator.

    Science.gov (United States)

    Nagashima, Hisayuki; Kondo, Tomohide; Nagoya, Tomoki; Ikeda, Toru; Kurimata, Naoko; Unoke, Shohei; Seto, Yasuo

    2015-08-07

    A field-portable gas chromatograph-mass spectrometer (Hapsite ER system) was evaluated for the detection of chemical warfare agents (CWAs) in the vapor phase. The system consisted of Tri-Bed concentrator gas sampler (trapping time: 3s(-1)min), a nonpolar low thermal-mass capillary gas chromatography column capable of raising temperatures up to 200°C, a hydrophobic membrane-interfaced electron ionization quadrupole mass spectrometer evacuated by a non-evaporative getter pump for data acquisition, and a personal computer for data analysis. Sample vapors containing as little as 22μg sarin (GB), 100μg soman (GD), 210μg tabun (GA), 55μg cyclohexylsarin (GF), 4.8μg sulfur mustard, 390μg nitrogen mustard 1, 140μg of nitrogen mustard 2, 130μg nitrogen mustard 3, 120μg of 2-chloroacetophenone and 990μg of chloropicrin per cubic meter could be confirmed after Tri-Bed micro-concentration (for 1min) and automated AMDIS search within 12min. Using manual deconvolution by background subtraction of neighboring regions on the extracted ion chromatograms, the above-mentioned CWAs could be confirmed at lower concentration levels. The memory effects were also examined and we found that blister agents showed significantly more carry-over than nerve agents. Gasoline vapor was found to interfere with the detection of GB and GD, raising the concentration limits for confirmation in the presence of gasoline by both AMDIS search and manual deconvolution; however, GA and GF were not subject to interference by gasoline. Lewisite 1, and o-chlorobenzylidene malononitrile could also be confirmed by gas chromatography, but it was hard to quantify them. Vapors of phosgene, chlorine, and cyanogen chloride could be confirmed by direct mass spectrometric detection at concentration levels higher than 2, 140, and 10mg/m(3) respectively, by bypassing the micro-concentration trap and gas chromatographic separation. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Nerve autografts and tissue-engineered materials for the repair of peripheral nerve injuries: a 5-year bibliometric analysis

    Directory of Open Access Journals (Sweden)

    Yuan Gao

    2015-01-01

    Full Text Available With advances in biomedical methods, tissue-engineered materials have developed rapidly as an alternative to nerve autografts for the repair of peripheral nerve injuries. However, the materials selected for use in the repair of peripheral nerve injuries, in particular multiple injuries and large-gap defects, must be chosen carefully. Various methods and materials for protecting the healthy tissue and repairing peripheral nerve injuries have been described, and each method or material has advantages and disadvantages. Recently, a large amount of research has been focused on tissue-engineered materials for the repair of peripheral nerve injuries. Using the keywords "pe-ripheral nerve injury", "autotransplant", "nerve graft", and "biomaterial", we retrieved publications using tissue-engineered materials for the repair of peripheral nerve injuries appearing in the Web of Science from 2010 to 2014. The country with the most total publications was the USA. The institutions that were the most productive in this field include Hannover Medical School (Germany, Washington University (USA, and Nantong University (China. The total number of publications using tissue-engineered materials for the repair of peripheral nerve injuries grad-ually increased over time, as did the number of Chinese publications, suggesting that China has made many scientific contributions to this field of research.

  12. Modeling and optimization of a double-well double-barrier GaN/AlGaN/GaN/AlGaN resonant tunneling diode

    Science.gov (United States)

    Liu, Yang; Gao, Bo; Gong, Min; Shi, Ruiying

    2017-06-01

    The influence of a GaN layer as a sub-quantum well for an AlGaN/GaN/AlGaN double barrier resonant tunneling diode (RTD) on device performance has been investigated by means of numerical simulation. The introduction of the GaN layer as the sub-quantum well turns the dominant transport mechanism of RTD from the 3D-2D model to the 2D-2D model and increases the energy difference between tunneling energy levels. It can also lower the effective height of the emitter barrier. Consequently, the peak current and peak-to-valley current difference of RTD have been increased. The optimal GaN sub-quantum well parameters are found through analyzing the electrical performance, energy band, and transmission coefficient of RTD with different widths and depths of the GaN sub-quantum well. The most pronounced electrical parameters, a peak current density of 5800 KA/cm2, a peak-to-valley current difference of 1.466 A, and a peak-to-valley current ratio of 6.35, could be achieved by designing RTD with the active region structure of GaN/Al0.2Ga0.8 N/GaN/Al0.2Ga0.8 N (3 nm/1.5 nm/1.5 nm/1.5 nm).

  13. Optogenetic probing of nerve and muscle function after facial nerve lesion in the mouse whisker system

    Science.gov (United States)

    Bandi, Akhil; Vajtay, Thomas J.; Upadhyay, Aman; Yiantsos, S. Olga; Lee, Christian R.; Margolis, David J.

    2018-02-01

    Optogenetic modulation of neural circuits has opened new avenues into neuroscience research, allowing the control of cellular activity of genetically specified cell types. Optogenetics is still underdeveloped in the peripheral nervous system, yet there are many applications related to sensorimotor function, pain and nerve injury that would be of great benefit. We recently established a method for non-invasive, transdermal optogenetic stimulation of the facial muscles that control whisker movements in mice (Park et al., 2016, eLife, e14140)1. Here we present results comparing the effects of optogenetic stimulation of whisker movements in mice that express channelrhodopsin-2 (ChR2) selectively in either the facial motor nerve (ChAT-ChR2 mice) or muscle (Emx1-ChR2 or ACTA1-ChR2 mice). We tracked changes in nerve and muscle function before and up to 14 days after nerve transection. Optogenetic 460 nm transdermal stimulation of the distal cut nerve showed that nerve degeneration progresses rapidly over 24 hours. In contrast, the whisker movements evoked by optogenetic muscle stimulation were up-regulated after denervation, including increased maximum protraction amplitude, increased sensitivity to low-intensity stimuli, and more sustained muscle contractions (reduced adaptation). Our results indicate that peripheral optogenetic stimulation is a promising technique for probing the timecourse of functional changes of both nerve and muscle, and holds potential for restoring movement after paralysis induced by nerve damage or motoneuron degeneration.

  14. Classification of neuromuscular blocking agents in a new neuromuscular preparation of the chick in vitro

    NARCIS (Netherlands)

    Riezen, H. van

    1968-01-01

    A neuromuscular preparation of the chick is described: 1. 1. The sciatic nerve-tibilis anterior muscle preparation of the 2–10 days old chick fulfils all criteria of an assay preparation and differentiates between curare-like and decamethonium-like agents. 2. 2. The preparation responds to

  15. Cranial nerve palsies

    International Nuclear Information System (INIS)

    Ruggieri, P.; Adelizzi, J.; Modic, M.T.; Ross, J.S.; Tkach, J.; Masaryk, T.J.

    1990-01-01

    This paper evaluates the utility of multiplanar reconstructions (MPRs) of three-dimensional (3D) MR angiography data sets in the examination of patients with cranial nerve palsies. The authors hypothesis was that 3D data could be reformatted to highlight the intricate spatial relationships of vessels to adjacent neural tissues by taking advantage of the high vessel-parenchyma contrast in high-resolution 3D time-of-flight sequences. Twenty patients with cranial nerve palsies and 10 asymptomatic patients were examined with coronal T1-weighted and axial T2-weighted imaging plus a gadolinium-enhanced 3D MRA sequence (40/7/15 degrees, axial 60-mm volume, 0.9-mm isotropic resolution). Cranial nerves II-VIII were subsequently evaluated on axial and reformatted coronal and/or sagittal images

  16. Use of Processed Nerve Allografts to Repair Nerve Injuries Greater Than 25 mm in the Hand.

    Science.gov (United States)

    Rinker, Brian; Zoldos, Jozef; Weber, Renata V; Ko, Jason; Thayer, Wesley; Greenberg, Jeffrey; Leversedge, Fraser J; Safa, Bauback; Buncke, Gregory

    2017-06-01

    Processed nerve allografts (PNAs) have been demonstrated to have improved clinical results compared with hollow conduits for reconstruction of digital nerve gaps less than 25 mm; however, the use of PNAs for longer gaps warrants further clinical investigation. Long nerve gaps have been traditionally hard to study because of low incidence. The advent of the RANGER registry, a large, institutional review board-approved, active database for PNA (Avance Nerve Graft; AxoGen, Inc, Alachua, FL) has allowed evaluation of lower incidence subsets. The RANGER database was queried for digital nerve repairs of 25 mm or greater. Demographics, injury, treatment, and functional outcomes were recorded on standardized forms. Patients younger than 18 and those lacking quantitative follow-up data were excluded. Recovery was graded according to the Medical Research Council Classification for sensory function, with meaningful recovery defined as S3 or greater level. Fifty digital nerve injuries in 28 subjects were included. There were 22 male and 6 female subjects, and the mean age was 45. Three patients gave a previous history of diabetes, and there were 6 active smokers. The most commonly reported mechanisms of injury were saw injuries (n = 13), crushing injuries (n = 9), resection of neuroma (n = 9), amputation/avulsions (n = 8), sharp lacerations (n = 7), and blast/gunshots (n = 4). The average gap length was 35 ± 8 mm (range, 25-50 mm). Recovery to the S3 or greater level was reported in 86% of repairs. Static 2-point discrimination (s2PD) and Semmes-Weinstein monofilament (SWF) were the most common completed assessments. Mean s2PD in 24 repairs reporting 2PD data was 9 ± 4 mm. For the 38 repairs with SWF data, protective sensation was reported in 33 repairs, deep pressure in 2, and no recovery in 3. These data compared favorably with historical data for nerve autograft repairs, with reported levels of meaningful recovery of 60% to 88%. There were no reported adverse effects

  17. Electrodeless wet etching of n-GaN assisted with ultraviolet light

    International Nuclear Information System (INIS)

    Skriniarova, J.; Novotny, I.

    2012-01-01

    In this paper we studied photo-assisted electrodeless etching (ELPEC) of n-GaN in a K_2S_2O_8/KOH solution irradiated continuously with UV light. We investigated the impact of mask material on n-GaN patterning. As mask material thin layers of Ti, Pt and Au were used. The ratio of mask covered surface area to uncovered one was 7:1, 1:2 and 1:5. The K_2S_2O_8 oxidizing agent concentration was kept in the range from 0.006 to 0.1 M, the KOH electrolyte concentration was kept in the range from 0.004 to 0.04 M. (authors)

  18. Bipolar characteristics of AlGaN/AlN/GaN/AlGaN double heterojunction structure with AlGaN as buffer layer

    International Nuclear Information System (INIS)

    Peng, Enchao; Wang, Xiaoliang; Xiao, Hongling; Wang, Cuimei; Yin, Haibo; Chen, Hong; Feng, Chun; Jiang, Lijuan; Hou, Xun; Wang, Zhanguo

    2013-01-01

    Highlights: •2DEG and 2DHG coexist in the AlGaN/AlN/GaN/AlGaN DH-structure. •The sheet densities of 2DEG and 2DHG vary with buffer Al content and GaN thickness. •The conditions for the disappearance of 2DHG are discussed. •Increasing buffer Al content provides better electron confinement. •Dislocation scattering is reduced in the DH-structure. -- Abstract: This is a theoretical study of AlGaN/AlN/GaN/AlGaN double heterojunction (DH) structure with AlGaN as buffer layer. Our calculation shows that as the buffer Al content increases, though two-dimensional electron gas (2DEG) sheet density decreases, the channel back-barrier caused by polarization-induced electric field in GaN provides better electron confinement. And under certain conditions the DH-structure shows bipolar characteristics, with an additional two-dimensional hole gas (2DHG) formed at GaN/AlGaN interface. The influence of the buffer Al content and GaN channel thickness on the 2DEG and 2DHG sheet densities are investigated, and the conditions for the disappearance of 2DHG are discussed. Also, the mobility inhibited by dislocation scattering is enhanced in DH-structure due to the enhancement of screening effect of the 2DEG

  19. Electron microscopic study of the myelinated nerve fibres and the perineurial cell basement membrane in the diabetic human peripheral nerves

    International Nuclear Information System (INIS)

    ElBarrany, Wagih G.; Hamdy, Raid M.; AlHayani, Abdulmonem A.; Jalalah, Sawsan M.

    2009-01-01

    To study the quantitative and ultrastructural changes in myelinated nerve fibers and the basement membranes of the perineurial cells in diabetic nerves. The study was performed at the Department of Anatomy, Faculty of Medicine, King Abdul-Aziz University, Jeddah, Saudi Arabia from 2003 to 2005. Human sural nerves were obtained from 15 lower limbs and 5 diabetic nerve biopsies. The total mean and density of myelinated nerve fibers per fascicle were calculated, with density of microtubules and mitochondria in the axoplasm. The number of the perineurial cell basement membrane layers was counted, and thickness of the basement membrane was measured. Among the 15 diabetic and 5 normal human sural nerves, the average diameters, number and surface area of myelinated nerve fibers and axonal microtubules density were found to be less in diabetic nerves. Mitochondrial density was higher in diabetic axons. Thickness of the perineurial cell basement membrane had a greater mean, but the number of perineurial cell layers was less than that of the diabetic group. The inner cellular layer of the perineurium of the diabetic nerves contained large vacuoles containing electron-dense degenerated myelin. A few specimens showed degenerated myelinated nerve fibers, while others showed recovering ones. Retracted axoplasms were encountered with albumin extravasation. Diabetes caused an increase in perineurial permeability. The diabetic sural nerve showed marked decrease in the myelinated nerve fibres, increase degenerated mitochondria, and decreased microtubules. (author)

  20. Labeling of antibodies with a 67Ga-phenolic aminocarboxylic acid chelate. Pt. 1

    International Nuclear Information System (INIS)

    Schuhmacher, J.; Matys, R.; Hauser, H.; Maier-Borst, W.; Matzku, S.

    1986-01-01

    As a chelating agent for labeling antibodies (Abs) with metallic radionuclides, a propionic acid substituted ethylenediamine N, N'-di-[(o-hydroxyphenyl) acetic acid] (P-EDDHA), which tighly complexes 67 Ga, was synthetized. The 67 Ga-P-EDDHA chelate was coupled in aqueous solution to IgG at a molar ratio of 1:1 via carbodiimide. The average coupling yield was 15%. A specific activity of 4 mCi/mg IgG could be obtained with commercially supplied 67 Ga. In vitro stability was evaluated in human serum at 37 0 C and showed a half-life of about 120 h for the release of 67 Ga from the labeled Ab during the initial phase of incubation. This in vitro halflife is similar to that measured for 111 In-DTPA labeled Abs. Because of the high stability of the 67 Ga-P-EDDHA chelate, the in vivo formation of radioactive lebeled transferrin by transchelation, as described for 111 In-DTPA labeled Abs, should, however, be reduced by this labeling technique. (orig.)

  1. Neurophysiological approach to disorders of peripheral nerve

    DEFF Research Database (Denmark)

    Crone, Clarissa; Krarup, Christian

    2013-01-01

    Disorders of the peripheral nerve system (PNS) are heterogeneous and may involve motor fibers, sensory fibers, small myelinated and unmyelinated fibers and autonomic nerve fibers, with variable anatomical distribution (single nerves, several different nerves, symmetrical affection of all nerves......, plexus, or root lesions). Furthermore pathological processes may result in either demyelination, axonal degeneration or both. In order to reach an exact diagnosis of any neuropathy electrophysiological studies are crucial to obtain information about these variables. Conventional electrophysiological...

  2. Effect of diabetic retinopathy and panretinal photocoagulation on retinal nerve fiber layer and optic nerve appearance.

    Science.gov (United States)

    Lim, Michele C; Tanimoto, Suzana A; Furlani, Bruno A; Lum, Brent; Pinto, Luciano M; Eliason, David; Prata, Tiago S; Brandt, James D; Morse, Lawrence S; Park, Susanna S; Melo, Luiz A S

    2009-07-01

    To determine if panretinal photocoagulation (PRP) alters retinal nerve fiber layer (RNFL) thickness and optic nerve appearance. Patients with diabetes who did and did not undergo PRP and nondiabetic control subjects were enrolled in a prospective study. Participants underwent optical coherence tomography of the peripapillary retina and optic nerve. Stereoscopic optic nerve photographs were graded in a masked fashion. Ninety-four eyes of 48 healthy individuals, 89 eyes of 55 diabetic patients who did not undergo PRP, and 37 eyes of 24 subjects with diabetes who underwent PRP were included in this study. Eyes that had been treated with PRP had thinner peripapillary RNFL compared with the other groups; this was statistically significantly different in the inferior (P = .004) and nasal (P = .003) regions. Optic nerve cupping did not increase with severity of disease classification, but the proportion of optic nerves graded as suspicious for glaucoma or as having nonglaucomatous optic neuropathy did (P = .008). These grading categories were associated with thinner RNFL measurements. Diabetic eyes that have been treated with PRP have thinner RNFL than nondiabetic eyes. Optic nerves in eyes treated with PRP are more likely to be graded as abnormal, but their appearance is not necessarily glaucomatous and may be related to thinning of the RNFL.

  3. Clinical aspects of percutaneous poisoning by the chemical warfare agent VX: effects of application site and decontamination.

    Science.gov (United States)

    Hamilton, Murray G; Hill, Ira; Conley, John; Sawyer, Thomas W; Caneva, Duane C; Lundy, Paul M

    2004-11-01

    O-ethyl S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) is an extremely toxic organophosphate nerve agent that has been weaponized and stockpiled in a number of different countries, and it has been used in recent terrorist events. It differs from other well-known organophosphate nerve agents in that its primary use is as a contact poison rather than as an inhalation hazard. For this reason, we examined the effects of application site and skin decontamination on VX toxicity in anesthetized domestic swine after topical application. VX applied to the surface of the ear rapidly resulted in signs of toxicity consistent with the development of cholinergic crisis, including apnea and death. VX on the epigastrium resulted in a marked delayed development of toxic signs, reduced toxicity, and reduction in the rate of cholinesterase depression compared with animals exposed on the ear. Skin decontamination (15 minutes post-VX on the ear) arrested the development of clinical signs and prevented further cholinesterase inhibition and death. These results confirm earlier work that demonstrates the importance of exposure site on the resultant toxicity of this agent and they also show that decontamination postexposure has the potential to be an integral and extremely important component of medical countermeasures against this agent.

  4. Effect of bupivacaine and adjuvant drugs for regional anesthesia on nerve tissue oximetry and nerve blood flow

    Directory of Open Access Journals (Sweden)

    Wiesmann T

    2018-01-01

    Full Text Available Thomas Wiesmann,1 Stefan Müller,1,2 Hans-Helge Müller,3 Hinnerk Wulf,1 Thorsten Steinfeldt1,4 1Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, University Hospital Marburg, Philipps University, Marburg, 2Department of Anesthesiology and Intensive Care Medicine, University Hospital Giessen, Justus-Liebig-University, Giessen, 3Institute of Medical Biometry and Epidemiology, Philipps University, Marburg, 4Department of Anesthesiology and Intensive Care Medicine, Diakoniekrankenhaus Schwäbisch Hall, Schwäbisch Hall, Germany Background: Nerve blood flow has a critical role in acute and chronic pathologies in peripheral nerves. Influences of local anesthetics and adjuvants on tissue perfusion and oxygenation are deemed as relevant factors for nerve damage after peripheral regional anesthesia. The link between low tissue perfusion due to local anesthetics and resulting tissue oxygenation is unclear.Methods: Combined tissue spectrophotometry and laser-Doppler flowmetry were used to assess nerve blood flow in 40 surgically exposed median nerves in pigs, as well as nerve tissue oximetry for 60 min. After baseline measurements, test solutions saline (S, bupivacaine (Bupi, bupivacaine with epinephrine (BupiEpi, and bupivacaine with clonidine (BupiCloni were applied topically.Results: Bupivacaine resulted in significant decrease in nerve blood flow, as well as tissue oximetry values, compared with saline control. Addition of epinephrine resulted in a rapid, but nonsignificant, reduction of nerve blood flow and extensive lowering of tissue oximetry levels. The use of clonidine resulted in a reduction of nerve blood flow, comparable to bupivacaine alone (relative blood flow at T60 min compared with baseline, S: 0.86 (0.67–1.18, median (25th–75th percentile; Bupi: 0.33 (0.25–0.60; BupiCloni: 0.43 (0.38–0.63; and BupiEpi: 0.41(0.30–0.54. The use of adjuvants did not result in any relevant impairment of tissue oximetry

  5. Magnetic resonance imaging of blood brain/nerve barrier dysfunction and leukocyte infiltration: closely related or discordant?

    Directory of Open Access Journals (Sweden)

    Gesa eWeise

    2012-12-01

    Full Text Available Unlike other organs the nervous system is secluded from the rest of the organism by the blood brain (BBB or blood nerve barrier (BNB preventing passive influx of fluids from the circulation. Similarly, leukocyte entry to the nervous system is tightly controlled. Breakdown of these barriers and cellular inflammation are hallmarks of inflammatory as well as ischemic neurological diseases and thus represent potential therapeutic targets. The spatiotemporal relationship between BBB/BNB disruption and leukocyte infiltration has been a matter of debate. We here review contrast-enhanced magnetic resonance imaging (MRI as a non-invasive tool to depict barrier dysfunction and its relation to macrophage infiltration in the central and peripheral nervous system under pathological conditions. Novel experimental contrast agents like Gadofluorine M (Gf allow more sensitive assessment of BBB dysfunction than conventional Gadolinium (Gd-DTPA-enhanced MRI. In addition, Gf facilitates visualization of functional and transient alterations of the BBB remote from lesions. Cellular contrast agents such as superparamagnetic iron oxide particles (SPIO and perfluorocarbons (PFC enable assessment of leukocyte (mainly macrophage infiltration by MR technology. Combined use of these MR contrast agents disclosed that leukocytes can enter the nervous system independent from a disturbance of the BBB, and vice versa, a dysfunctional BBB/BNB by itself is not sufficient to attract inflammatory cells from the circulation. We will illustrate these basic imaging findings in animal models of multiple sclerosis (MS, cerebral ischemia and traumatic nerve injury and review corresponding findings in patients.

  6. Ephaptic coupling of myelinated nerve fibers

    DEFF Research Database (Denmark)

    Binczak, S.; Eilbeck, J. C.; Scott, Alwyn C.

    2001-01-01

    Numerical predictions of a simple myelinated nerve fiber model are compared with theoretical results in the continuum and discrete limits, clarifying the nature of the conduction process on an isolated nerve axon. Since myelinated nerve fibers are often arranged in bundles, this model is used...

  7. ECV profiling of GaAs and GaN HEMT heterostructures

    Science.gov (United States)

    Yakovlev, G.; Zubkov, V.

    2018-03-01

    AlGaAs/InGaAs/GaAs and AlGaN/GaN HEMT heterostructures were investigated by means of electrochemical capacitance-voltage technique. A set of test structures were fabricated using various doping techniques: standard doping, δ-doping GaAs pHEMT and nondoping GaN HEMT. The concentration profiles of free charge carriers across the samples were experimentally obtained. The QW filling was analyzed and compared for different mechanisms of emitter doping and 2DEG origins.

  8. Topical administration of adrenergic receptor pharmaceutics and nerve growth factor

    Directory of Open Access Journals (Sweden)

    Jena J Steinle

    2010-06-01

    Full Text Available Jena J SteinleDepartments of Ophthalmology and Anatomy and Neurobiology, Hamilton Eye Institute, University of Tennessee Health Science Center, Memphis, TN 38163, USAAbstract: Topical application of nerve growth factor (NGF and adrenergic receptor pharmaceutics are currently in use for corneal ulcers and glaucoma. A recent interest in the neuroprotective abilities of NGF has led to a renewed interest in NGF as a therapeutic for retinal and choroidal diseases. NGF can promote cell proliferation through actions of the TrkA receptor or promote apoptosis through receptor p75NTR. This understanding has led to novel interest in the role of NGF for diseases of the posterior eye. The role of β-adrenergic receptor agonists and antagonists for treatments of glaucoma, diabetic retinopathy, and their potential mechanisms of action, are still under investigation. This review discusses the current knowledge and applications of topical NGF and adrenergic receptor drugs for ocular disease.Keywords: NGF, β-adrenergic receptor agents, α-adrenergic receptor agents, retina, cornea, glaucoma

  9. Comparison of electrical characteristic between AlN/GaN and AlGaN/GaN heterostructure Schottky diodes

    International Nuclear Information System (INIS)

    Lü Yuan-Jie; Feng Zhi-Hong; Gu Guo-Dong; Dun Shao-Bo; Yin Jia-Yun; Han Ting-Ting; Cai Shu-Jun; Lin Zhao-Jun

    2014-01-01

    Ni/Au Schottky contacts on AlN/GaN and AlGaN/GaN heterostructures are fabricated. Based on the measured current—voltage and capacitance—voltage curves, the electrical characteristics of AlN/GaN Schottky diode, such as Schottky barrier height, turn-on voltage, reverse breakdown voltage, ideal factor, and the current-transport mechanism, are analyzed and then compared with those of an AlGaN/GaN diode by self-consistently solving Schrödinger's and Poisson's equations. It is found that the dislocation-governed tunneling is dominant for both AlN/GaN and AlGaN/GaN Schottky diodes. However, more dislocation defects and a thinner barrier layer for AlN/GaN heterostructure results in a larger tunneling probability, and causes a larger leakage current and lower reverse breakdown voltage, even though the Schottky barrier height of AlN/GaN Schottky diode is calculated to be higher that of an AlGaN/GaN diode. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  10. Imaging of the facial nerve

    Energy Technology Data Exchange (ETDEWEB)

    Veillon, F. [Service de Radiologie I, Hopital de Hautepierre, 67098 Strasbourg Cedex (France)], E-mail: Francis.Veillon@chru-strasbourg.fr; Ramos-Taboada, L.; Abu-Eid, M. [Service de Radiologie I, Hopital de Hautepierre, 67098 Strasbourg Cedex (France); Charpiot, A. [Service d' ORL, Hopital de Hautepierre, 67098 Strasbourg Cedex (France); Riehm, S. [Service de Radiologie I, Hopital de Hautepierre, 67098 Strasbourg Cedex (France)

    2010-05-15

    The facial nerve is responsible for the motor innervation of the face. It has a visceral motor function (lacrimal, submandibular, sublingual glands and secretion of the nose); it conveys a great part of the taste fibers, participates to the general sensory of the auricle (skin of the concha) and the wall of the external auditory meatus. The facial mimic, production of tears, nasal flow and salivation all depend on the facial nerve. In order to image the facial nerve it is mandatory to be knowledgeable about its normal anatomy including the course of its efferent and afferent fibers and about relevant technical considerations regarding CT and MR to be able to achieve high-resolution images of the nerve.

  11. Surgical management of third nerve palsy

    Directory of Open Access Journals (Sweden)

    Anupam Singh

    2016-01-01

    Full Text Available Third nerve paralysis has been known to be associated with a wide spectrum of presentation and other associated factors such as the presence of ptosis, pupillary involvement, amblyopia, aberrant regeneration, poor bell′s phenomenon, superior oblique (SO overaction, and lateral rectus (LR contracture. Correction of strabismus due to third nerve palsy can be complex as four out of the six extraocular muscles are involved and therefore should be approached differently. Third nerve palsy can be congenital or acquired. The common causes of isolated third nerve palsy in children are congenital (43%, trauma (20%, inflammation (13%, aneurysm (7%, and ophthalmoplegic migraine. Whereas, in adult population, common etiologies are vasculopathic disorders (diabetes mellitus, hypertension, aneurysm, and trauma. Treatment can be both nonsurgical and surgical. As nonsurgical modalities are not of much help, surgery remains the main-stay of treatment. Surgical strategies are different for complete and partial third nerve palsy. Surgery for complete third nerve palsy may involve supra-maximal recession - resection of the recti. This may be combined with SO transposition and augmented by surgery on the other eye. For partial third nerve, palsy surgery is determined according to nature and extent of involvement of extraocular muscles.

  12. Surgical management of third nerve palsy

    Science.gov (United States)

    Singh, Anupam; Bahuguna, Chirag; Nagpal, Ritu; Kumar, Barun

    2016-01-01

    Third nerve paralysis has been known to be associated with a wide spectrum of presentation and other associated factors such as the presence of ptosis, pupillary involvement, amblyopia, aberrant regeneration, poor bell's phenomenon, superior oblique (SO) overaction, and lateral rectus (LR) contracture. Correction of strabismus due to third nerve palsy can be complex as four out of the six extraocular muscles are involved and therefore should be approached differently. Third nerve palsy can be congenital or acquired. The common causes of isolated third nerve palsy in children are congenital (43%), trauma (20%), inflammation (13%), aneurysm (7%), and ophthalmoplegic migraine. Whereas, in adult population, common etiologies are vasculopathic disorders (diabetes mellitus, hypertension), aneurysm, and trauma. Treatment can be both nonsurgical and surgical. As nonsurgical modalities are not of much help, surgery remains the main-stay of treatment. Surgical strategies are different for complete and partial third nerve palsy. Surgery for complete third nerve palsy may involve supra-maximal recession - resection of the recti. This may be combined with SO transposition and augmented by surgery on the other eye. For partial third nerve, palsy surgery is determined according to nature and extent of involvement of extraocular muscles. PMID:27433033

  13. Influence of AlGaN/GaN superlattice inserted structure on the performance of InGaN/GaN multiple quantum well light emitting diodes

    International Nuclear Information System (INIS)

    Wang, C.-L.; Tsai, M.-C.; Gong, J.-R.; Liao, W.-T.; Lin, P.-Y.; Yen, K.-Y.; Chang, C.-C.; Lin, H.-Y.; Hwang, S.-K.

    2007-01-01

    Investigations were conducted to explore the effect of Al 0.3 Ga 0.7 N/GaN short-period superlattice (SPSL)-inserted structures in the GaN under layer on the performance of In 0.2 Ga 0.8 N/GaN multiple quantum well (MQW) light emitting diodes (LEDs). The Al 0.3 Ga 0.7 N/GaN SPSL-inserted LEDs were found to exhibit improved materials and device characteristics including decrements in ideality factor and reverse leakage current. The results of etch pit counts reveal that SPSL-induced threading dislocation density reduction in the SPSL-inserted In 0.2 Ga 0.8 N/GaN MQW LED structures enables the improved LED performance

  14. Facial Nerve Paralysis due to a Pleomorphic Adenoma with the Imaging Characteristics of a Facial Nerve Schwannoma

    OpenAIRE

    Nader, Marc-Elie; Bell, Diana; Sturgis, Erich M.; Ginsberg, Lawrence E.; Gidley, Paul W.

    2014-01-01

    Background Facial nerve paralysis in a patient with a salivary gland mass usually denotes malignancy. However, facial paralysis can also be caused by benign salivary gland tumors. Methods We present a case of facial nerve paralysis due to a benign salivary gland tumor that had the imaging characteristics of an intraparotid facial nerve schwannoma. Results The patient presented to our clinic 4 years after the onset of facial nerve paralysis initially diagnosed as Bell palsy. Computed tomograph...

  15. Growth of GaN layers using Ga2O vapor obtained from Ga and H2O vapor

    International Nuclear Information System (INIS)

    Sumi, Tomoaki; Taniyama, Yuuki; Takatsu, Hiroaki; Juta, Masami; Kitamoto, Akira; Imade, Mamoru; Yoshimura, Masashi; Mori, Yusuke; Isemura, Masashi

    2015-01-01

    In this study, we performed growth of GaN layers using Ga 2 O vapor synthesized from Ga and H 2 O vapor. In this process, we employed H 2 O vapor instead of HCl gas in hydride vapor phase epitaxy (HVPE) to synthesize Ga source gas. In the synthesis reaction of Ga 2 O, a Ga 2 O 3 whisker formed and covered Ga, which impeded the synthesis reaction of Ga 2 O. The formation of the Ga 2 O 3 whisker was suppressed in H 2 ambient at high temperatures. Then, we adopted this process to supply a group III precursor and obtained an epitaxial layer. X-ray diffraction (XRD) measurement revealed that the epitaxial layer was single-crystalline GaN. Growth rate increased linearly with Ga 2 O partial pressure and reached 104 µm/h. (author)

  16. Calcium regulation in frog peripheral nerve by the blood-nerve barrier

    International Nuclear Information System (INIS)

    Wadhwani, K.C.

    1986-01-01

    The objectives of this research were: (a) to investigate the characteristics of calcium transport across the perineurium and the endoneurial capillaries, and (b) to gain a better understanding of the extent of calcium homeostasis in the endoneurial space. To study the nature of calcium transport across the perineurium, the flux of radiotracer 45 Ca was measured through the perineurial cylinder, isolated from the frog sciatic nerve, and through the perineurium into the nerve in situ. To study the nature of calcium transport across the endoneurial capillaries, the permeability-surface area product (PA) of 45 Ca was determined as a function of the calcium concentration in the blood. To study calcium homeostasis, the calcium content of the frog sciatic nerve was determined as a function of chronic changes in plasma [Ca

  17. Intraoperative cochlear nerve mapping with the mobile cochlear nerve compound action potential tracer in vestibular schwannoma surgery.

    Science.gov (United States)

    Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi

    2018-05-18

    OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.

  18. Regeneration of Optic Nerve

    Directory of Open Access Journals (Sweden)

    Kwok-Fai So

    2011-05-01

    Full Text Available The optic nerve is part of the central nervous system (CNS and has a structure similar to other CNS tracts. The axons that form the optic nerve originate in the ganglion cell layer of the retina and extend through the optic tract. As a tissue, the optic nerve has the same organization as the white matter of the brain in regard to its glia. There are three types of glial cells: Oligodendrocytes, astrocytes, and microglia. Little structural and functional regeneration of the CNS takes place spontaneously following injury in adult mammals. In contrast, the ability of the mammalian peripheral nervous system (PNS to regenerate axons after injury is well documented. A number of factors are involved in the lack of CNS regeneration, including: (i the response of neuronal cell bodies against the damage; (ii myelin-mediated inhibition by oligodendrocytes; (iii glial scarring, by astrocytes; (iv macrophage infiltration; and (v insufficient trophic factor support. The fundamental difference in the regenerative capacity between CNS and PNS neuronal cell bodies has been the subject of intensive research. In the CNS the target normally conveys a retrograde trophic signal to the cell body. CNS neurons die because of trophic deprivation. Damage to the optic nerve disconnects the neuronal cell body from its target-derived trophic peptides, leading to the death of retinal ganglion cells. Furthermore, the axontomized neurons become less responsive to the peptide trophic signals they do receive. On the other hand, adult PNS neurons are intrinsically responsive to neurotrophic factors and do not lose trophic responsiveness after axotomy. In this talk different strategies to promote optic-nerve regeneration in adult mammals are reviewed. Much work is still needed to resolve many issues. This is a very important area of neuroregeneration and neuroprotection, as currently there is no cure after traumatic optic nerve injury or retinal disease such as glaucoma, which

  19. The effects of irreversible electroporation (IRE on nerves.

    Directory of Open Access Journals (Sweden)

    Wei Li

    Full Text Available BACKGROUND: If a critical nerve is circumferentially involved with tumor, radical surgery intended to cure the cancer must sacrifice the nerve. Loss of critical nerves may lead to serious consequences. In spite of the impressive technical advancements in nerve reconstruction, complete recovery and normalization of nerve function is difficult to achieve. Though irreversible electroporation (IRE might be a promising choice to treat tumors near or involved critical nerve, the pathophysiology of the nerve after IRE treatment has not be clearly defined. METHODS: We applied IRE directly to a rat sciatic nerve to study the long term effects of IRE on the nerve. A sequence of 10 square pulses of 3800 V/cm, each 100 µs long was applied directly to rat sciatic nerves. In each animal of group I (IRE the procedure was applied to produce a treated length of about 10 mm. In each animal of group II (Control the electrodes were only applied directly on the sciatic nerve for the same time. Electrophysiological, histological, and functional studies were performed on immediately after and 3 days, 1 week, 3, 5, 7 and 10 weeks following surgery. FINDINGS: Electrophysiological, histological, and functional results show the nerve treated with IRE can attain full recovery after 7 weeks. CONCLUSION: This finding is indicative of the preservation of nerve involving malignant tumors with respect to the application of IRE pulses to ablate tumors completely. In summary, IRE may be a promising treatment tool for any tumor involving nerves.

  20. Photoluminescence study of the nitrogen content effect on GaAs/GaAs1-xNx/GaAs/AlGaAs: (Si) quantum well

    International Nuclear Information System (INIS)

    Hamdouni, A.; Bousbih, F.; Ben bouzid, S.; Aloulou, S.; Harmand, J.C.; Chtourou, R.

    2008-01-01

    We study the effect of nitrogen content in modulation-doped GaAs/GaAs 1-x N x /GaAs/GaAlAs:(Si) quantum well using low-temperature photoluminescence spectroscopy. The samples were grown on GaAs (001) substrates by molecular-beam epitaxy with different nitrogen compositions. The variation of the nitrogen composition from 0.04% to 0.32% associated to the bi-dimensional electron gas gives a new interaction mode between the nitrogen localized states and the GaAs 1-x N x /GaAs energies levels. The red-shift observed in photoluminescence spectra as function of nitrogen content has been interpreted in the frame of the band anticrossing model