WorldWideScience

Sample records for nelson river hvdc

  1. Nelson River and Hudson Bay

    Science.gov (United States)

    2002-01-01

    Rivers that empty into large bodies of water can have a significant impact on the thawing of nearshore winter ice. This true-color Moderate Resolution Imaging Spectroradiometer (MODIS) image from May 18, 2001, shows the Nelson River emptying spring runoff from the Manitoba province to the south into the southwestern corner of Canada's Hudson Bay. The warmer waters from more southern latitudes hasten melting of ice near the shore, though some still remained, perhaps because in shallow coastal waters, the ice could have been anchored to the bottom. High volumes of sediment in the runoff turned the inflow brown, and the rim of the retreating ice has taken on a dirty appearance even far to the east of the river's entrance into the Bay. The sediment would have further hastened the melting of the ice because its darker color would have absorbed more solar radiation than cleaner, whiter ice. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC

  2. A report on the fisheries resources of the lower Nelson River and the impacts of hydroelectric development, 1988 data

    International Nuclear Information System (INIS)

    Swanson, G.M.; Kansas, K.R.; Matkowski, S.M.

    1990-01-01

    Fisheries studies on the lower Nelson River (Manitoba) system have had the goals of gaining an understanding of the fisheries resources present, assessing current and potential impacts of hydroelectric developments, and investigating enhancement or mitigative options. In 1988, a resource inventory of McMillan and 12-Mile Creeks was conducted to increase understanding of brook trout stocks in the Limestone River system. Results indicate that both streams contain self-sustaining populations. Baseline data collection in the Conawapa Forebay of the Nelson River was initiated in 1988. Inventories of fish populations were conducted, focusing on lake sturgeon. Three long-term monitoring projects were continued in 1988, investigating the populations of spawning brook trout, larval brook trout, and anadromy in brook trout. Four major tributaries to the Nelson River were classified on the basis of physical and chemical characteristics in an attempt to understand brook trout distribution patterns. Ten sturgeon were captured in Angling Lake in 1988 and fitted with radio tags to assess the importance of the Angling Lake-Angling River system to Nelson River lake sturgeon. To investigate the feasibility of enhancing brook trout populations in the Nelson River system, baskets of eggs were planted in previously identified spawning areas in three creeks in 1988. The eggs developed and hatched only in CN Creek. The potential for rehabilitating the Kettle River brook trout population by transfer of fish from other rivers was also investigated in 1988. Radio-tagged fish remained in the Kettle River-Long Spruce system throughout the life of the tags and appear to have found suitable summer and winter habitat. 60 refs., 76 figs., 38 tabs

  3. Hydrology signal from GRACE gravity data in the Nelson River basin, Canada: a comparison of two approaches

    Science.gov (United States)

    Li, Tanghua; Wu, Patrick; Wang, Hansheng; Jia, Lulu; Steffen, Holger

    2018-03-01

    The Gravity Recovery and Climate Experiment (GRACE) satellite mission measures the combined gravity signal of several overlapping processes. A common approach to separate the hydrological signal in previous ice-covered regions is to apply numerical models to simulate the glacial isostatic adjustment (GIA) signals related to the vanished ice load and then remove them from the observed GRACE data. However, the results of this method are strongly affected by the uncertainties of the ice and viscosity models of GIA. To avoid this, Wang et al. (Nat Geosci 6(1):38-42, 2013. https://doi.org/10.1038/NGEO1652; Geodesy Geodyn 6(4):267-273, 2015) followed the theory of Wahr et al. (Geophys Res Lett 22(8):977-980, 1995) and isolated water storage changes from GRACE in North America and Scandinavia with the help of Global Positioning System (GPS) data. Lambert et al. (Postglacial rebound and total water storage variations in the Nelson River drainage basin: a gravity GPS Study, Geological Survey of Canada Open File, 7317, 2013a, Geophys Res Lett 40(23):6118-6122, https://doi.org/10.1002/2013GL057973, 2013b) did a similar study for the Nelson River basin in North America but applying GPS and absolute gravity measurements. However, the results of the two studies in the Nelson River basin differ largely, especially for the magnitude of the hydrology signal which differs about 35%. Through detailed comparison and analysis of the input data, data post-processing techniques, methods and results of these two works, we find that the different GRACE data post-processing techniques may lead to this difference. Also the GRACE input has a larger effect on the hydrology signal amplitude than the GPS input in the Nelson River basin due to the relatively small uplift signal in this region. Meanwhile, the influence of the value of α , which represents the ratio between GIA-induced uplift rate and GIA-induced gravity-rate-of-change (before the correction for surface uplift), is more obvious in

  4. Stability analysis of multi-infeed HVDC system applying VSC-HVDC

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2010-01-01

    This paper presents a general model of dual infeed HVDC system applying VSC-HVDC, which can be used as an element in large multi infeed HVDC system. The model may have different structure under different grid faults because of the action of breakers. Hence power flow of the system based on this m...

  5. 77 FR 42327 - Proposed Supplementary Rules for the Morley Nelson Snake River Birds of Prey National...

    Science.gov (United States)

    2012-07-18

    ... a BLM-approved metal fire ring. On BLM-administered public land within the Morley Nelson Snake River... located on improved campsites within BLM-approved metal fire rings on all lands administered by the BLM... fires outside of BLM-approved fire rings would help avert human-caused wildfire which would protect...

  6. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr

    2015-11-15

    Highlights: • The role of SFCL in types of HVDC system was evaluated. • A simulation model based on Korea Jeju–Haenam HVDC power system was designed in Matlab/Simulink. • Utilizing the designed both HVDC power system models, the efficiency of DC-SFCL was relatively low, compared to AC-SFCL. • It was deduced that the AC-SFCL was more effective in LCC-HVDC system than VSC-HVDC system. - Abstract: High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  7. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    International Nuclear Information System (INIS)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook

    2015-01-01

    Highlights: • The role of SFCL in types of HVDC system was evaluated. • A simulation model based on Korea Jeju–Haenam HVDC power system was designed in Matlab/Simulink. • Utilizing the designed both HVDC power system models, the efficiency of DC-SFCL was relatively low, compared to AC-SFCL. • It was deduced that the AC-SFCL was more effective in LCC-HVDC system than VSC-HVDC system. - Abstract: High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  8. Power control method on VSC-HVDC in a hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2012-01-01

    Multi-infeed HVDC (MIDC) system connected with VSC-HVDC links and LCC-HVDC links is a new structure in modern power systems, which can be called hybrid multi-infeed HVDC (HMIDC) system. The paper presents the voltage stability analysis of a HMIDC system modeled from a possible future Danish power...

  9. Passive AC network supplying the integration of CCC-HVDC and VSC-HVDC systems

    OpenAIRE

    BIDADFAR, Ali; ABEDI, Mehrdad; KARRARI, Mehdi

    2014-01-01

    The integration of a capacitor-commutated converter (CCC) high-voltage direct current (HVDC) (CCC-HVDC) and voltage source converter (VSC) HVDC (VSC-HVDC) is proposed in this paper to supply entirely passive AC networks. The key point of this integration is the flat characteristic of the DC voltage of the CCC-HVDC, which provides the condition for the VSC to connect to the CCC DC link via a current regulator. The advantages of the proposed combined infeeding system are the requirement o...

  10. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook

    2015-11-01

    High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  11. Report on the workshop examining the potential effects of hydroelectric development on Beluga of the Nelson River Estuary, Winnipeg, Manitoba, November 6 and 7, 1990

    International Nuclear Information System (INIS)

    Lawrence, M.J.; Paterson, M.; Baker, R.F.; Schmidt, R.

    1992-01-01

    A summary is presented of discussions and conclusions at a workshop held to examine the potential effects of hydroelectric development on beluga whales of the Nelson River estuary in Manitoba. Background information is provided on the estuary, beluga whales and their use of arctic and subarctic estuaries, and hydroelectric development on the Nelson River. Potential impacts of such development on the whales are reviewed in the categories of direct effects of changes in physical-chemical conditions (temperature and discharge), indirect effects of disturbances mediated through the food chain, and effects on socioeconomic conditions that may affect beluga whales. Since the biology of beluga whales and other phenomena of interest in this study are poorly known, recommendations are made for research and monitoring activities in the Nelson River estuary. In general, the workshop participants felt that changes in the estuary due to hydroelectric development would not be large enough to affect beluga whales strongly. 34 refs., 1 fig

  12. Short Circuit Ratio analysis of multi-infeed HVDC system with a VSC-HVDC link

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    As an important indicator of system stability, Short Circuit Ratio (SCR) is commonly used in power system analysis. For systems include HVDC link connection, the Effective SCR (ESCR) is mostly applied to indicate the strength of HVDC infeed bus. The contribution of VSC-HVDC link to multi......-infeed HVDC system stability has been analyzed a lot but the study on ESCR of this kind of system is still insufficient. This paper presents a calculation method for ESCR of the hybrid multi infeed HVDC system based on a simple two-infeed HVDC system model. The equivalent circuit of this system under short...... circuit situation is firstly obtained based on the model. Then its Thevenin equivalent circuit is derived and system ESCR can be calculated. At last, simulation study verified that the calculated ESCR value under different cases can indicate the change of system stability....

  13. HVDC keitiklių charakteristikų tyrimas

    OpenAIRE

    Miliauskas, Tadas

    2016-01-01

    Nowadays HVDC technology are rapidly evolving in the world. Number of HVDC interconnectios are constantly growing and a lot of asychonous systems are connected using the HVDC interconnections. There are two HVDC interconnections started working in Lithuania this year: NordBalt – Connection with Sweden and LitPol Link – connection with Poland. In this final project are widely considered LitPol Link system, investigating characteristics of this connection. Using modeling program ...

  14. Sedimentary Records of Hyperpycnal Flows and the Influence of River Damming on Sediment Dynamics of Estuaries: Examples from the Nelson, Churchill, Moisie and Sainte-Marguerite Rivers (Canada)

    Science.gov (United States)

    St-Onge, G.; Duboc, Q.; Boyer-Villemaire, U.; Lajeunesse, P.; Bernatchez, P.

    2015-12-01

    Sediment cores were sampled in the estuary of the Nelson and Churchill Rivers in western Hudson Bay, as well as in the estuary of the Moisie and Sainte-Marguerite Rivers in Gulf of St. Lawrence in order to evaluate the impact of hydroelectric dams on the sedimentary regime of these estuaries. The gravity cores at the mouth of the Nelson River recorded several cm-thick rapidly deposited layers with a reverse to normal grading sequence, indicating the occurrence of hyperpycnal flows generated by major floods during the last few centuries. These hyperpycnal flows were probably caused by ice-jam formation, which can increase both the flow and the sediment concentration following the breaching of such natural dams. Following the construction of hydroelectric dams since the 1960s, the regulation of river discharge prevented the formation of hyperpycnal flows, and hence the deposition of hyperpycnites in the upper part of the cores. In the core sampled in the estuary of the Churchill River, only one hyperpycnite was recorded. This lower frequency may be due to the enclosed estuary of the Churchill River, its weaker discharge and the more distal location of the coring site.In the Gulf of St. Lawrence, grain size measurements allowed the identification of a major flood around AD 1844±4 years in box cores from both the Sainte-Marguerite and Moisie Rivers, whereas a drastic decrease in variations in the median grain size occurred around AD ~1900 in the estuary of the Sainte-Marguerite River, highlighting the offshore impact of the SM1 dam construction in the early 1900s. Furthermore, sedimentological variations in the box cores from both estuaries have been investigated by wavelet analysis and the sharp disappearance of high frequencies around AD 1900 in the estuary of the dammed river (Sainte-Marguerite River), but not in the estuary of the natural river (Moisie River), also provides evidence of the influence of dams on the sedimentary regime of estuaries.

  15. Voltage sensitivity based reactive power control on VSC-HVDC in a wind farm connected hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2013-01-01

    With increasing application of both Line Commutated Converter based High Voltage Direct Current (LCC-HVDC) systems and Voltage Source Converter based HVDC (VSC-HVDC) links, a new type of system structure named Hybrid Multi-Infeed HVDC (HMIDC) system is formed in the modern power systems. This paper...... presents the operation and control method of the wind farm connected HMIDC system. The wind power fluctuation takes large influence to the system voltages. In order to reduce the voltage fluctuation of LCC-HVDC infeed bus caused by the wind power variation, a voltage sensitivity-based reactive power...

  16. 78 FR 56224 - Hydro Nelson, Ltd.; Hydro-WM, LLC; Notice of Transfer of Exemption

    Science.gov (United States)

    2013-09-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 3401-049] Hydro Nelson, Ltd.; Hydro-WM, LLC; Notice of Transfer of Exemption 1. By documentation filed July 8, 2013 and supplemented... Hydro-WM, LLC. The project is located on the Rockfish River in Nelson County, Virginia. The transfer of...

  17. Controller Architecture Design for MMC-HVDC

    Directory of Open Access Journals (Sweden)

    ZHANG, B.

    2014-05-01

    Full Text Available Compared with high voltage direct current (HVDC, the primary and secondary systems of modular multilevel converter based HVDC (MMC-HVDC are complicated. And the characteristics of the control system determine the properties of the MMC-HVDC system to a certain extent. This paper investigates the design of control architecture. First, the structure and parameters of the 21-level MMC-HVDC are designed. Second, the framework of the control system is studied in details and a complete control system is established. The communication mode and content are built between each layer, and the control system program is developed and debugged. Then The steady state test platform of the sub-module and the relevant control system are designed. Finally, the steady-state tests and the system test of the physical MMC-HVDC simulation system are conducted, which prove that the SMC can control the sub-module (SM efficiently, and the control system could realize efficient start and stop of the physical system. Meanwhile, the capacitor voltage balance between the sub-modules and the basic fault protection and control of the DC voltage and power are verified to be effective.

  18. HVDC transmission from nuclear power plant

    International Nuclear Information System (INIS)

    Yoshida, Yukio; Takenaka, Kiyoshi; Taniguchi, Haruto; Ueda, Kiyotaka

    1980-01-01

    HVDC transmission directly from a nuclear power plant is expected as one of the bulk power transmission systems from distant power generating area. Successively from the analysis of HVDC transmission from BWR-type nuclear power plant, this report discusses dynamic response characteristics of HVDC transmission (double poles, two circuits) from PWR type nuclear power plant due to dc-line faults (DC-1LG, 2LG) and ac-line faults (3LG) near inverter station. (author)

  19. Non-Pilot Protection of the HVDC Grid

    Science.gov (United States)

    Badrkhani Ajaei, Firouz

    This thesis develops a non-pilot protection system for the next generation power transmission system, the High-Voltage Direct Current (HVDC) grid. The HVDC grid protection system is required to be (i) adequately fast to prevent damages and/or converter blocking and (ii) reliable to minimize the impacts of faults. This study is mainly focused on the Modular Multilevel Converter (MMC) -based HVDC grid since the MMC is considered as the building block of the future HVDC systems. The studies reported in this thesis include (i) developing an enhanced equivalent model of the MMC to enable accurate representation of its DC-side fault response, (ii) developing a realistic HVDC-AC test system that includes a five-terminal MMC-based HVDC grid embedded in a large interconnected AC network, (iii) investigating the transient response of the developed test system to AC-side and DC-side disturbances in order to determine the HVDC grid protection requirements, (iv) investigating the fault surge propagation in the HVDC grid to determine the impacts of the DC-side fault location on the measured signals at each relay location, (v) designing a protection algorithm that detects and locates DC-side faults reliably and sufficiently fast to prevent relay malfunction and unnecessary blocking of the converters, and (vi) performing hardware-in-the-loop tests on the designed relay to verify its potential to be implemented in hardware. The results of the off-line time domain transients studies in the PSCAD software platform and the real-time hardware-in-the-loop tests using an enhanced version of the RTDS platform indicate that the developed HVDC grid relay meets all technical requirements including speed, dependability, security, selectivity, and robustness. Moreover, the developed protection algorithm does not impose considerable computational burden on the hardware.

  20. Separate Poles Mode for Large-Capacity HVDC System

    Science.gov (United States)

    Zhu, Lin; Gao, Qin

    2017-05-01

    This paper proposes a novel connection mode, separate poles mode (SPM), for large-capacity HVDC systems. The proposed mode focuses on the core issues of HVDC connection in interconnected power grids and principally aims at increasing effective electric distance between poles, which helps to mitigate the interaction problems between AC system and DC system. Receiving end of bipolar HVDC has been divided into different inverter stations under the mode, and thus significantly alleviates difficulties in power transmission and consumption of receiving-end AC grids. By investigating the changes of multi-feed short-circuit ratio (MISCR), finding that HVDC with SPM shows critical impacts upon itself and other HVDC systems with conventional connection mode, which demonstrates that SPM can make balance between MISCR increase and short-circuit current limit.

  1. HVDC grids for offshore and supergrid of the future

    CERN Document Server

    Gomis-Bellmunt, Oriol; Liang, Jun

    2016-01-01

    Presents the advantages, challenges, and technologies of High Voltage Direct Current (HVDC) Grids This book discusses HVDC grids based on multi-terminal voltage-source converters (VSC), which is suitable for the connection of offshore wind farms and a possible solution for a continent wide overlay grid. HVDC Grids: For Offshore and Supergrid of the Future begins by introducing and analyzing the motivations and energy policy drives for developing offshore grids and the European Supergrid. HVDC transmission technology and offshore equipment are described in the second part of the book. The third part of the book discusses how HVDC grids can be developed and integrated in the existing power system. The fourth part of the book focuses on HVDC grid integration, in studies, for different time domains of electric power systems. The book concludes by discussing developments of advanced control methods and control devices for enabling DC grids.

  2. Topologies of multiterminal HVDC-VSC transmission for large offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Gomis-Bellmunt, Oriol [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2. 08028 Barcelona (Spain); IREC Catalonia Institute for Energy Research, Barcelona (Spain); Liang, Jun; Ekanayake, Janaka; King, Rosemary; Jenkins, Nicholas [School of Engineering, Cardiff University, Queen' s Buildings, The Parade, Cardiff CF24 3AA, Wales (United Kingdom)

    2011-02-15

    Topologies of multiterminal HVDC-VSC transmission systems for large offshore wind farms are investigated. System requirements for multiterminal HVDC are described, particularly the maximum power loss allowed in the event of a fault. Alternative control schemes and HVDC circuit topologies are reviewed, including the need for HVDC circuit breakers. Various topologies are analyzed and compared according to a number of criteria: number and capacity of HVDC circuits, number of HVDC circuit breakers, maximum power loss, flexibility, redundancy, lines utilization, need for offshore switching platforms and fast communications. (author)

  3. Study on the characteristics of multi-infeed HVDC

    Science.gov (United States)

    Li, Ming; Song, Xinli; Liu, Wenzhuo; Xiang, Yinxing; Zhao, Shutao; Su, Zhida; Meng, Hang

    2017-09-01

    China has built more than ten HVDC transmission projects in recent years [1]. Now, east China has formed a multi-HVDC feed pattern grid. It is imminent to study the interaction of the multi-HVDC and the characteristics of it. In this paper, an electromechanical-electromagnetic hybrid model is built with electromechanical data of a certain power network. We use electromagnetic models to simulate the HVDC section and electromechanical models simulate the AC power network [2]. In order to study the characteristics of the grid, this paper adds some faults to the line and analysed the fault characteristics. At last give analysis of the fault characteristics.

  4. Modeling and simulation of large HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Jin, H.; Sood, V.K.

    1993-01-01

    This paper addresses the complexity and the amount of work in preparing simulation data and in implementing various converter control schemes and the excessive simulation time involved in modelling and simulation of large HVDC systems. The Power Electronic Circuit Analysis program (PECAN) is used to address these problems and a large HVDC system with two dc links is simulated using PECAN. A benchmark HVDC system is studied to compare the simulation results with those from other packages. The simulation time and results are provided in the paper.

  5. A Novel Topology of Hybrid HVDC Circuit Breaker for VSC-HVDC Application

    Directory of Open Access Journals (Sweden)

    Van-Vinh Nguyen

    2017-10-01

    Full Text Available The use of high voltage direct current (HVDC circuit breakers (CBs with the capabilities of bidirectional fault interruption, reclosing, and rebreaking can improve the reliable and safe operation of HVDC grids. Although several topologies of CBs have been proposed to perform these capabilities, the limitation of these topologies is either high on-state losses or long time interruption in the case bidirectional fault current interruption. Long time interruption results in the large magnitude of the fault current in the voltage source converter based HVDC (VSC-HVDC system due to the high rate of rise of fault current. This paper proposes a new topology of hybrid CB (HCB with lower conduction loss and lower interruption time to solve the problems. The proposed topology is based on the inverse current injection method, which uses the capacitor to enforce the fault current to zero. In the case of the bidirectional fault current interruption, the capacitor does not change its polarity after identifying the direction of fault current, which can reduce the interruption time accordingly. A switching control algorithm for the proposed topology is presented in detail. Different operation modes of proposed HCB, such as normal current mode, breaking fault current mode, discharging, and reversing capacitor voltage modes after clearing the fault, are considered in the proposed algorithm. The proposed topology with the switching control algorithm is tested in a simulation-based system. Different simulation scenarios such as temporary and permanent faults are carried out to verify the performance of the proposed topology. The simulation is performed in the Matlab/Simulink environment.

  6. Modeling and application of VSC-HVDC in the European transmission system

    International Nuclear Information System (INIS)

    L'Abatte, A.; Fulli, G.

    2010-01-01

    This paper investigated the potential technical, environmental, and economic impacts of voltage source converter (VSC) based high voltage direct current (HVDC) technologies on the European power system, with particular emphasis on enhancing the attainable transmission capacity in specific applications. To this end, an original steady-state model of the VSC-HVDC was presented and tested. A techno-economic analysis of the potential impact of VSC-HVDC on liberalized power systems in Europe was performed to determine the feasibility of such investment compared to building conventional high voltage alternating current (HVAC) transmission infrastructures. The land use and environmental impact of HVDC may be lower than HVAC technologies. VSC-HVDC offers several advantages over conventional HVDC, including flexibility and range of power control, compactness and modularity of converter stations, easier expandability for multi-terminal configurations, and greater environmental friendliness. The relative disadvantages of the VSC-HVDC include a greater expense and higher converter losses. When replacing existing HVAC lines, some targeted VSC-HVDC installations were shown to be technologically and economically feasible, particularly when installed on lines between regions with a high electricity price differential, although less profitable than building new HVAC lines. VSC-HVDC can be a more feasible option when socio-political and environmental restraints curtail the extension of the HVAC transmission system. 29 refs., 6 tabs., 4 figs.

  7. Coordinated frequency regulation by offshore wind farms and VSC-HVDC transmission

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2014-01-01

    converter-based HVDC (VSC-HVDC) transmission system to participate in power system frequency regulation. The strategy explores the frequency support capability of offshore wind farms and VSC-HVDC. By implementing the proposed coordinated control, the VSCHVDC link is able to provide quick virtual inertial...... are presented to demonstrate the frequency regulation capability of VSC-HVDC and validate the effectiveness of the proposed coordinated control strategy....

  8. Nelson syndrome: definition and management.

    Science.gov (United States)

    Barber, T M; Adams, E; Wass, J A H

    2014-01-01

    Nelson syndrome is an important complication of treatment with total bilateral adrenalectomy (TBA) for patients with refractory Cushing's disease. Although early cases of Nelson syndrome often presented with the clinical features of large sellar masses, the modern face of Nelson syndrome has changed primarily due to earlier detection (with highly resolved magnetic resonance imaging (MRI) and sensitive ACTH assays) and greater awareness of the condition, resulting in reduced morbidity and mortality. Although lack of administration of neoadjuvant pituitary radiotherapy post-TBA surgery may predict future development of Nelson syndrome, other predictive factors remain controversial. Therefore, Nelson syndrome should be screened for closely and long-term in all patients with a history of Cushing's disease and TBA. The diagnosis of Nelson syndrome remains controversial, and the pathogenesis of this condition is incompletely understood. Current hypotheses include the "released negative feedback" mechansism (residual pituitary corticotropinoma cells are "released" from the negative feedback effects of cortisol following TBA), and the "aggressive corticotropinoma" mechanism (Nelson syndrome is most likely to develop in those patients with refractory treatments - including TBA - for an underlying aggressive corticotropinoma). Effective management of Nelson syndrome with pituitary surgery and radiotherapy is often a challenge. Other therapies (such as Gamma Knife surgery and temozolomide) play an important role and merit further research into their efficacy and placement in the management pathway of Nelson syndrome. © 2014 Elsevier B.V. All rights reserved.

  9. Wind Farm Grid Integration Using VSC Based HVDC Transmission - An Overview

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2008-01-01

    The paper gives an overview of HVAC and HVDC connection of wind farm to the grid, with an emphasis on Voltage Source Converter (VSC)-based HVDC for large wind farms requiring long distance cable connection. Flexible control capabilities of a VSC-based HVDC system enables smooth integration of wind...... farm into the power grid network while meeting the Grid Code Requirements (GCR). Operation of a wind farm with VSC-based HVDC connection is described....

  10. HVDC power transmission technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, R.L.; Tatro, P.J.; Railing, B.D. [New England Power Service Co., Westborough, MA (United States); Johnson, B.K.; Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States); Fink, J.L.

    1997-04-01

    The purpose of this study was to develop an assessment of the national utility system`s needs for electric transmission during the period 1995-2020 that could be met by future reduced-cost HVDC systems. The assessment was to include an economic evaluation of HVDC as a means for meeting those needs as well as a comparison with competing technologies such as ac transmission with and without Flexible AC Transmission System (FACTS) controllers. The role of force commutated dc converters was to be assumed where appropriate. The assessment begins by identifying the general needs for transmission in the U.S. in the context of a future deregulated power industry. The possible roles for direct current transmission are then postulated in terms of representative scenarios. A few of the scenarios are illustrated with the help of actual U.S. system examples. non-traditional applications as well as traditional applications such as long lines and asynchronous interconnections are discussed. The classical ``break-even distance`` concept for comparing HVDC and ac lines is used to assess the selected scenarios. The impact of reduced-cost converters is reflected in terms of the break-even distance. This report presents a comprehensive review of the functional benefits of HVDC transmission and updated cost data for both ac and dc system components. It also provides some provocative thoughts on how direct current transmission might be applied to better utilize and expand our nation`s increasingly stressed transmission assets.

  11. A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques

    Science.gov (United States)

    Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.

    2017-05-01

    With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.

  12. HVDC transmission from isorated nuclear power plant

    International Nuclear Information System (INIS)

    Takenaka, Kiyoshi; Takasaki, Masahiro; Ichikawa, Tatemi; Hayashi, Toshiyuki

    1985-01-01

    HVDC transmission directly from nuclear power plant is considered as one of the patterns of long distance and large capacity transmission system. This reports considers two route HVDC transmission from PWR type nuclear power plant, and analyzes dynamic response characteristics due to bus fault, main protection failure and etc. using the AC-DC Power System Simulator. (author)

  13. Transient analysis of an HTS DC power cable with an HVDC system

    Science.gov (United States)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun; Yang, Byeongmo

    2013-11-01

    The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.

  14. HVDC System Characteristics and Simulation Models

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S.I.; Han, B.M.; Jang, G.S. [Electric Enginnering and Science Research Institute, Seoul (Korea)

    2001-07-01

    This report deals with the AC-DC power system simulation method by PSS/E and EUROSTAG for the development of a strategy for the reliable operation of the Cheju-Haenam interconnected system. The simulation using both programs is performed to analyze HVDC simulation models. In addition, the control characteristics of the Cheju-Haenam HVDC system as well as Cheju AC system characteristics are described in this work. (author). 104 figs., 8 tabs.

  15. Investigation of Hybrid Pseudo Bipolar HVDC Performances Supply Power to Passive AC Network

    Directory of Open Access Journals (Sweden)

    Kuan Li

    2014-07-01

    Full Text Available The traditional HVDC plays an important role in the development of power grid. But the traditional HVDC cannot supply power either to entirely passive AC network or to weak AC system. In fact, an entirely passive AC network can be effectively powered through VSC-HVDC. However, the cost of investment in VSC-HVDC is amazingly high due to the limitation of power electronics technology. Based on CSC and VSC, this paper proposes a method to build Hybrid HVDC, which makes the power supply to the passive AC network come true and, at the same time, lowers the investment cost. The effect of topology, steady mathematical model, startup characteristic, steady and transient characteristics in Hybrid HVDC system are systematically studied in this paper. The simulation result shows that Hybrid HVDC can supply power to the passive AC network with high stability. This study provides a theoretical basis for the further development of HVDC.

  16. Assessment on the influence of resistive superconducting fault current limiter in VSC-HVDC system

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Park, Byung-Bae; Lee, Bang-Wook

    2014-09-01

    Due to fewer risk of commutation failures, harmonic occurrences and reactive power consumptions, Voltage Source Converter (VSC) based HVDC system is known as the optimum solution of HVDC power system for the future power grid. However, the absence of suitable fault protection devices for HVDC system hinders the efficient VSC-HVDC power grid design. In order to enhance the reliability of the VSC-HVDC power grid against the fault current problems, the application of resistive Superconducting Fault Current Limiters (SFCLs) could be considered. Also, SFCLs could be applied to the VSC-HVDC system with integrated AC Power Systems in order to enhance the transient response and the robustness of the system. In this paper, in order to evaluate the role of SFCLs in VSC-HVDC systems and to determine the suitable position of SFCLs in VSC-HVDC power systems integrated with AC power System, a simulation model based on Korea Jeju-Haenam HVDC power system was designed in Matlab Simulink/SimPowerSystems. This designed model was composed of VSC-HVDC system connected with an AC microgrid. Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred. Consequently, it was found that the simulation model was effective to evaluate the positive effects of resistive SFCLs for the effective suppression of fault currents in VSC-HVDC systems as well as in integrated AC Systems. Finally, the optimum locations of SFCLs in VSC-HVDC transmission systems were suggested based on the simulation results.

  17. Transient Voltage Stability Analysis and Improvement of A Network with different HVDC Systems

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    This paper presents transient voltage stability analysis of an AC system with multi-infeed HVDC links including a traditional LCC HVDC link and a VSC HVDC link. It is found that the voltage supporting capability of the VSC-HVDC link is significantly influenced by the tie-line distance between the...

  18. Control of offshore wind farms with HVDC grid connection

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, Stefan; Weise, Bernd; Poeller, Markus [DIgSILENT GmbH, Gomaringen (Germany)

    2010-07-01

    This paper analyzes various aspects related to the operation of HVDC connected offshore wind farms. The main interest is on the behavior during on- and offshore faults. Different control strategies for VSC-HVDC and ''classical'' thyristor-based HVDC links are presented and analyzed via network simulations. Wind generators with fully-rated converters and wind generators with doubly-fed induction generators are considered as generator types. The feasibility, advantages and disadvantages of the various options are discussed in detail. (orig.)

  19. Definition and Classification of Terms for HVDC Networks

    DEFF Research Database (Denmark)

    Vrana, Til Kristian; Bell, Keith; Sørensen, Poul Ejnar

    2015-01-01

    A systematic terminology for the field of HVDC networks has been developed, closing the gap between the well-established terminologies from AC power systems and HVDC technology. The most relevant items, topologies and concepts have been given clear and unique defined names, and these have been cl...

  20. Economic Aspect of HVDC Transmission System for Indonesia Consideration in Nuclear Power Development

    International Nuclear Information System (INIS)

    Edwaren Liun

    2009-01-01

    As a country with hundreds million people, Indonesia needs to generate large scale power and distribute it to thorough country to improve gross domestic product of the population. In the power transmission domain, the High Voltage Direct Current (HVDC) transmission system should be considered for the next decades concerning any technical and economical problems with HVAC transmission. HVDC transmission system is the answer for the Indonesian condition. This system can connect the high energy potential regions to the high energy demand regions. HVDC is the most efficient to transport energy from one region to another one region. Dismantling and removing assets costs are included to the estimated for capital costs, while the environmental and property costs are the costs of securing designations and resource consents, and valuation and legal advice for the HVDC investment. Although converter terminals are expensive however, for long transmissions HVDC system can compensate the costs over breakeven distance through very efficient transmission system. Efficiency of HVDC is appearing from conductor wire, supporting tower, low energy loses and free space used by route of the transmission line. HVDC system is also free from some problem, concerning stability, inductive and capacitive load components, phase differences and frequency system. In the economic aspect the HVDC capital costs for the transmission options comprise estimates of the cost to design, purchase and construct new HVDC transmission components. While operating and maintenance costs of HVDC assets comprise the costs for replacement the old existing overhead transmission lines, underground and submarine cables, and HVDC converter station components. (author)

  1. Transient analysis of an HTS DC power cable with an HVDC system

    International Nuclear Information System (INIS)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun; Yang, Byeongmo

    2013-01-01

    Highlights: •A model of an HTS DC power cable was developed using real time digital simulator. •The simulations of the HTS DC power cable in connection with an HVDC system were performed. •The transient analysis results of the HTS DC power cable were presented. -- Abstract: The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system

  2. Transient analysis of an HTS DC power cable with an HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@cwnu.ac.kr [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Yang, Byeongmo [Korea Electric Power Research Institute, 105 Munji-Ro, Yuseong-Gu, Daejon 305-760 (Korea, Republic of)

    2013-11-15

    Highlights: •A model of an HTS DC power cable was developed using real time digital simulator. •The simulations of the HTS DC power cable in connection with an HVDC system were performed. •The transient analysis results of the HTS DC power cable were presented. -- Abstract: The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.

  3. Assessment on the influence of resistive superconducting fault current limiter in VSC-HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong-Geon; Khan, Umer Amir; Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Park, Byung-Bae; Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr

    2014-09-15

    Highlights: • The role of SFCLs in VSC-HVDC systems was evaluated. • Simulation model based on Korea Jeju-Haenam HVDC power system was designed. • An effect and the feasible locations of resistive SFCLs were evaluated. • DC line-to-line, DC line-to-ground and 3 phase AC faults were imposed and analyzed. - Abstract: Due to fewer risk of commutation failures, harmonic occurrences and reactive power consumptions, Voltage Source Converter (VSC) based HVDC system is known as the optimum solution of HVDC power system for the future power grid. However, the absence of suitable fault protection devices for HVDC system hinders the efficient VSC-HVDC power grid design. In order to enhance the reliability of the VSC-HVDC power grid against the fault current problems, the application of resistive Superconducting Fault Current Limiters (SFCLs) could be considered. Also, SFCLs could be applied to the VSC-HVDC system with integrated AC Power Systems in order to enhance the transient response and the robustness of the system. In this paper, in order to evaluate the role of SFCLs in VSC-HVDC systems and to determine the suitable position of SFCLs in VSC-HVDC power systems integrated with AC power System, a simulation model based on Korea Jeju-Haenam HVDC power system was designed in Matlab Simulink/SimPowerSystems. This designed model was composed of VSC-HVDC system connected with an AC microgrid. Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred. Consequently, it was found that the simulation model was effective to evaluate the positive effects of resistive SFCLs for the effective suppression of fault currents in VSC-HVDC systems as well as in integrated AC Systems. Finally, the optimum locations of SFCLs in VSC-HVDC transmission systems were suggested based on the simulation results.

  4. Assessment on the influence of resistive superconducting fault current limiter in VSC-HVDC system

    International Nuclear Information System (INIS)

    Lee, Jong-Geon; Khan, Umer Amir; Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Park, Byung-Bae; Lee, Bang-Wook

    2014-01-01

    Highlights: • The role of SFCLs in VSC-HVDC systems was evaluated. • Simulation model based on Korea Jeju-Haenam HVDC power system was designed. • An effect and the feasible locations of resistive SFCLs were evaluated. • DC line-to-line, DC line-to-ground and 3 phase AC faults were imposed and analyzed. - Abstract: Due to fewer risk of commutation failures, harmonic occurrences and reactive power consumptions, Voltage Source Converter (VSC) based HVDC system is known as the optimum solution of HVDC power system for the future power grid. However, the absence of suitable fault protection devices for HVDC system hinders the efficient VSC-HVDC power grid design. In order to enhance the reliability of the VSC-HVDC power grid against the fault current problems, the application of resistive Superconducting Fault Current Limiters (SFCLs) could be considered. Also, SFCLs could be applied to the VSC-HVDC system with integrated AC Power Systems in order to enhance the transient response and the robustness of the system. In this paper, in order to evaluate the role of SFCLs in VSC-HVDC systems and to determine the suitable position of SFCLs in VSC-HVDC power systems integrated with AC power System, a simulation model based on Korea Jeju-Haenam HVDC power system was designed in Matlab Simulink/SimPowerSystems. This designed model was composed of VSC-HVDC system connected with an AC microgrid. Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred. Consequently, it was found that the simulation model was effective to evaluate the positive effects of resistive SFCLs for the effective suppression of fault currents in VSC-HVDC systems as well as in integrated AC Systems. Finally, the optimum locations of SFCLs in VSC-HVDC transmission systems were suggested based on the simulation results

  5. Variation among sub-basins of the upper Nelson River in relationships between precipitation, runoff and the Pacific Decadal Oscillation

    International Nuclear Information System (INIS)

    McCullough, G.

    2008-01-01

    In this paper, I examine relationships between precipitation and river discharge in the Nelson River watershed and several global climate indices. Inter-decadal patterns in discharge and precipitation for several sub-basins closely tracked the Pacific Decadal Oscillation (PDO) through much of the 20th century. The PDO explained 53% of the variability in precipitation and 70% in discharge for the Red River (5-y averages) from 1915-1975. However, since 1975, both precipitation and discharge have increased relative to trend of the PDO. Winnipeg River discharge likewise increased relative to the PDO, but diverged earlier, beginning in 1965. The hydrograph of the Saskatchewan River followed the PDO only until mid-century, after which discharge declined relative to the PDO. The decline of discharge in the Saskatchewan River is not matched by consistent declines in precipitation, but may be partly due to consumptive use, mainly irrigation, and losses due to evaporation from large reservoirs created in the 1960s and 1970s. However, the increases in the Red and Winnipeg River are well-explained by increased spring and summer precipitation. For instance, precipitation was 20-30% higher in the decade 1996-2005 than in the previous decade. By examining historical data, we show the runoff coefficient to increase with increasing discharge, and that the proportional increase is greater in the Red than in the Winnipeg River basin. In the Red, the moderate difference in precipitation was amplified into a doubling of annual mean discharge. Comparing the same 2 periods, a smaller 10% increase in precipitation in the Winnipeg River basin explains a 27% increase in discharge. (author)

  6. Mixing and photoreactivity of dissolved organic matter in the Nelson/Hayes estuarine system (Hudson Bay, Canada)

    Science.gov (United States)

    Guéguen, C.; Mokhtar, M.; Perroud, A.; McCullough, G.; Papakyriakou, T.

    2016-09-01

    This work presents the results of a 4-year study (2009-2012) investigating the mixing and photoreactivity of dissolved organic matter (DOM) in the Nelson/Hayes estuary (Hudson Bay). Dissolved organic carbon (DOC), colored DOM, and humic-like DOM decreased with increasing salinity (r2 = 0.70-0.84). Removal of DOM was noticeable at low to mid salinity range, likely due to degradation and/or adsorption to particles. DOM photobleaching rates (i.e., decrease in DOM signal resulting from exposure to solar radiation) ranged from 0.005 to 0.030 h- 1, corresponding to half-lives of 4.9-9.9 days. Dissolved organic matter from the Nelson and Hayes Rivers was more photoreactive than from the estuary where the photodegradation of terrestrial DOM decreased with increasing salinity. Coincident with the loss of CDOM absorption was an increase in spectral slope S, suggesting a decrease in DOM molecular weight. Marked differences in photoreactivity of protein- and humic-like DOM were observed with highly humidified material being the most photosensitive. Information generated by our study will provide a valuable data set for better understanding the impacts of future hydroelectric development and climate change on DOM biogeochemical dynamics in the Nelson/Hayes estuary and coastal domain. This study will constitute a reference on terrestrial DOM fate prior to building additional generating capacity on the Nelson River.

  7. Control of transformerless MMC-HVDC during asymmetric grid faults

    DEFF Research Database (Denmark)

    Timofejevs, Artjoms; Gamboa, Daniel; Liserre, Marco

    2013-01-01

    Modular multilevel converter (MMC) is the latest converter topology suitable for the transformerless applications in HVDC transmission. HVDC systems are required to remain connected during grid faults, provide grid support and completely decouple the healthy side from the faulty one. The MMC...

  8. A Review of LCC-HVDC and VSC-HVDC Technologies and Applications

    Directory of Open Access Journals (Sweden)

    Oluwafemi Emmanuel Oni

    2016-09-01

    Full Text Available High Voltage Direct Current (HVDC systems has been an alternative method of transmitting electric power from one location to another with some inherent advantages over AC transmission systems. The efficiency and rated power carrying capacity of direct current transmission lines highly depends on the converter used in transforming the current from one form to another (AC to DC and vice versa. A well configured converter reduces harmonics, increases power transfer capabilities, and reliability in that it offers high tolerance to fault along the line. Different HVDC converter topologies have been proposed, built and utilised all over the world. The two dominant types are the line commutated converter LCC and the voltage source converter VSC. This review paper evaluates these two types of converters, their operational characteristics, power rating capability, control capability and losses. The balance of the paper addresses their applications, advantages, limitations and latest developments with these technologies.

  9. A Flexible Power Control Method of VSC-HVDC Link for the Enhancement of Effective Short-Circuit Ratio in a Hybrid Multi-Infeed HVDC System

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2013-01-01

    . To evaluate the contribution of the VSC-HVDC link on the voltage stability of HMIDC system, this paper proposes an effective short circuit ratio (ESCR) calculation method. Through the calculation, the voltage support capability of the VSC-HVDC link can be quantitatively represented by the ESCR. Furthermore......, based on the calculation results, a flexible power control strategy for the VSC-HVDC link is developed to provide maximum reactive power support under grid faults. The theoretical analysis of the HMIDC system is based on the Danish transmission grid, evaluated through PSCAD simulations under different...

  10. Stability Enhancement of Multi machine AC Systems by Synchronverter HVDC control

    Directory of Open Access Journals (Sweden)

    Raouia Aouini

    2016-06-01

    Full Text Available This paper investigates the impact of the Synchronverter based HVDC control on power system stability. The study considers multi machine power systems, with realistic parameters. A specific tuning method of the parameters of the regulators is used. The proposed control scheme is based on the sensitivity of the poles of the HVDC neighbor zone to the control parameters, and next, on their placement using residues. The transient stability of the HVDC neighbor zone is a priori taken into account at the design stage. The new tuning method is evaluated in comparison with the standard vector control via simulation tests. Extensive tests are performed using Matlab/Simulink implementation of the IEEE 9 bus/3 machines test system. The results prove the superiority of the proposed control to the classic vector control. The synchronverter control allows to improve not only the local performances of the HVDC link, but also the overall transient stability of the AC zone in which the HVDC is inserted. (where

  11. Comparison of alternative offshore wind farms and HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, M. [Technische Univ. Dresden (Germany); Lilje, P.; Poeller, M. [DIgSILENT GmbH, Gomaringen (Germany); Basteck, A. [Voith Turbo Wind GmbH und Co. KG, Crailsheim (Germany)

    2010-07-01

    This paper investigates the stability of offshore wind farms connected to the main power system via HVDC systems. Wind farms consisting of different ratios of directly connected synchronous machines and doubly-fed induction machines are considered. In addition, both conventional LCC- and VSC-type HVDC systems are considered. Furthermore, different control strategies are considered. Furthermore, different control strategies are considered for the VSC-based system, including constant frequency control and frequency regulation. The stability analysis is done by means of time-domain simulation. The maximum and minimum ratio of the two wind turbine technologies is found for each of the different HVDC systems. (orig.)

  12. Review of VSC HVDC Connection for Offshore Wind Power Integration

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei; Zhao, Haoran

    2016-01-01

    Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) connection has become a new trend for long distance offshore wind power transmission. It has been confirmed by a lot of research that the maximum distance of a High Voltage Alternative Current (HVAC) sub-marine cable transmission...... system is limited due to surplus charging current of the cables. The VSC HVDC transmission system has the ability to overcome the limitation and offers other advantages over the HVAC transmission system. This paper is to review the VSC HVDC transmission technology and its application for offshore wind...

  13. Optimization-based reactive power control in HVDC-connected wind power plants

    OpenAIRE

    Schönleber, Kevin; Collados Rodríguez, Carlos; Teixeira Pinto, Rodrigo; Ratés Palau, Sergi; Gomis Bellmunt, Oriol

    2017-01-01

    One application of high–voltage dc (HVdc) systems is the connection of remotely located offshore wind power plants (WPPs). In these systems, the offshore WPP grid and the synchronous main grid operate in decoupled mode, and the onshore HVdc converter fulfills the grid code requirements of the main grid. Thus, the offshore grid can be operated independently during normal conditions by the offshore HVdc converter and the connected wind turbines. In general, it is well known that optimized react...

  14. Modelling and Simulation of SVPWM Based Vector Controlled HVDC Light Systems

    Directory of Open Access Journals (Sweden)

    Ajay Kumar MOODADLA

    2012-11-01

    Full Text Available Recent upgrades in power electronics technology have lead to the improvements of insulated gate bipolar transistor (IGBT based Voltage source converter High voltage direct current (VSC HVDC transmission systems. These are also commercially known as HVDC Light systems, which are popular in renewable, micro grid, and electric power systems. Out of different pulse width modulation (PWM schemes, Space vector PWM (SVPWM control scheme finds growing importance in power system applications because of its better dc bus utilization. In this paper, modelling of the converter is described, and SVPWM scheme is utilized to control the HVDC Light system in order to achieve better DC bus utilization, harmonic reduction, and for reduced power fluctuations. The simulations are carried out in the MATLAB/SIMULINK environment and the results are provided for steady state and dynamic conditions. Finally, the performance of SVPWM based vector controlled HVDC Light transmission system is compared with sinusoidal pulse width modulation (SPWM based HVDC Light system in terms of output voltage and total harmonic distortion (THD.

  15. PowerFactory model for multi-terminal HVDC network with DC voltage droop control

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei

    Nowadays, most of the installed HVDC systems are based on line commutated converters (LCC), since this technology offers a series of advantages, mainly low costs and losses. However, voltage source converters (VSCs) have recently drawn more and more attention, due to their high controllability....... Moreover, recent developments have improved efficiency and power quality. For multi-terminal HVDC grids, the advantages of VSCs become so large, that VSC-HVDC systems are the only viable solution. Nevertheless, no VSC-based multi-terminal HVDC grids exist to date. This is the reason for which many research...

  16. HVDC transmission from nuclear power plant

    International Nuclear Information System (INIS)

    Yoshida, Yukio; Takenaka, Kiyoshi; Ichikawa, Takemi; Ueda, Kiyotaka; Machida, Takehiko

    1979-01-01

    The HVDC transmission directly from nuclear power plants is one of the patterns of long distance and large capacity HVDC transmission systems. In this report, the double pole, two-circuit HVDC transmission from a BWR nuclear power plant is considered, and the dynamic response characteristics due to the faults in dc line and ac line of inverter side are analyzed, to clarify the dynamic characteristics of the BWR nuclear power plant and dc system due to system faults and the effects of dc power control to prevent reactor scram. (1) In the instantaneous earthing fault of one dc line, the reactor is not scrammed by start-up within 0.8 sec. (2) When the earthing fault continues, power transmission drops to 75% by suspending the faulty pole, and the reactor is scrammed. (3) In the instantaneous ground fault of 2 dc lines, the reactor is not scrammed if the faulty dc lines are started up within 0.4 sec. (4) In the existing control of dc lines, the reactor is scrammed when the ac voltage at an ac-dc connection point largely drops due to ac failure. (J.P.N.)

  17. Nelson Syndrome: Update on Therapeutic Approaches.

    Science.gov (United States)

    Azad, Tej D; Veeravagu, Anand; Kumar, Sunny; Katznelson, Laurence

    2015-06-01

    To review the pathophysiology and therapeutic modalities availble for Nelson syndrome. We reviewed the current literature including managment for Nelson syndrome. For patients with NS, surgical intervention is often the first-line therapy. With refractory NS or tumors with extrasellar involvement, radiosurgery offers an important alternative or adjuvant option. Pharmacologic interventions have demonstrated limited usefulness, although recent evidence supports the feasibility of a novel somatostatin analog for patients with NS. Modern neuroimaging, improved surgical techniques, and the advent of stereotactic radiotherapy have transformed the management of NS. An up-to-date understanding of the pathophysiology underlying Nelson Syndrome and evidence-based management is imperative. Early detection may allow for more successful therapy in patients with Nelson Syndrome. Improved radiotherapeutic interventions and rapidly evolving pharmacologic therapies offer an opportunity to create targeted, multifocal treatment regiments for patients with Nelson Syndrome. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Control of a hybrid HVDC link to increase inter-regional power transfer

    DEFF Research Database (Denmark)

    Kotb, Omar; Ghandhari, Mehrdad; Eriksson, Robert

    2016-01-01

    This paper examines the application of a hybrid HVDC link in a two area power system with the purpose of increasing the inter-regional power transfer. A hybrid HVDC system combines both LCCs and VSCs, and hence it is capable of combining the benefits of both converter technologies, such as reduced...... cost and power losses due to the LCCs, and ability to connect to weak AC grids due to the VSCs. The mathematical model of the power system including the HVDC link is presented. The increase in inter-area power transfer is demonstrated and compared to the case when the hybrid HVDC link is not used....... Furthermore, the transient stability of the AC/DC power system was enhanced using auxiliary controllers for Power Oscillation Damping (POD). The results show the ability of the hybrid HVDC link to increase the unidirectional inter-area power transfer, while enhancing the transient stability of the power...

  19. Hybrid Models of Alternative Current Filter for Hvdc

    Directory of Open Access Journals (Sweden)

    Ufa Ruslan A.

    2017-01-01

    Full Text Available Based on a hybrid simulation concept of HVDC, the developed hybrid AC filter models, providing the sufficiently full and adequate modeling of all single continuous spectrum of quasi-steady-state and transient processes in the filter, are presented. The obtained results suggest that usage of the hybrid simulation approach is carried out a methodically accurate with guaranteed instrumental error solution of differential equation systems of mathematical models of HVDC.

  20. Modeling of Pressure Effects in HVDC Cables

    DEFF Research Database (Denmark)

    Szabo, Peter; Hassager, Ole; Strøbech, Esben

    1999-01-01

    A model is developed for the prediction of pressure effects in HVDC mass impregnatedcables as a result of temperature changes.To test the model assumptions, experiments were performed in cable like geometries.It is concluded that the model may predict the formation of gas cavities.......A model is developed for the prediction of pressure effects in HVDC mass impregnatedcables as a result of temperature changes.To test the model assumptions, experiments were performed in cable like geometries.It is concluded that the model may predict the formation of gas cavities....

  1. Study on emergency power control strategy for AC/DC hybrid power system containing VSC-HVDC

    Science.gov (United States)

    Liu, Lin; Hu, Zhenda; Ye, Rong; Lin, Zhangsui; Yang, Xiaodong; Yi, Yang

    2018-04-01

    This paper presents a comprehensive emergency power control strategy for AC/DC hybrid power systems containing VSC-HVDC. Firstly, the paper analyzes the power support of the VSC-HVDC to the AC lines using the Power Transferring Relativity Factor (PTRF). Then the power adjustment of the VSC-HVDC in several different circumstances are calculated. Finally, the online power control strategies of VSC-HVDC are designed, which could rapidly control the power of the VSC-HVDC, keeping the power flow of AC lines below the upper limit. Furthermore, the strategy is proven to be effective by the simulations with EMTDC/PSCAD.

  2. The Study on Hybrid Multi-Infeed HVDC System Connecting with Offshore Wind Farm

    DEFF Research Database (Denmark)

    Liu, Yan

    furnish the VSC-HVDC connected wind farm with a fast and reliable LVRT ability. The voltage fluctuation caused by the intermittent wind power is another important challenge to the system stability. As in the case of the LCC-HVDC links, their stable operations are highly dependent on the AC side voltage...... with the short electrical distance. And consequently, a so-called Multi-Infeed Direct Current (MIDC) transmission system is formed. On the other hand, as the fast growing of wind power in electrical grids, the Voltage Source Converter based HVDC (VSC-HVDC) links have becoming a favorable choice for connecting...

  3. Dynamic simulation of hvdc transmission systems on digital computers

    Energy Technology Data Exchange (ETDEWEB)

    Hingorani, N G; Hay, J L; Crosbie, R E

    1966-05-01

    A digital computer technique is based on the fact that the operation of an hvdc converter consists of similar consecutive processes, each process having features which are common to all processes. Each bridge converter of an hvdc system is represented by a central process, and repetitive use of the latter simulates continuous converter operation. This technique may be employed to obtain the waveforms of transient or steady state voltages and currents anywhere in the dc system. To illustrate the method, an hvdc link is considered; the link which connects two independent ac systems conprises two converters with their control systems, and a dc transmission line. As an example, the transient behavior of the system is examined following changes in the current settings of the control system.

  4. Product spaces and Nelson's inequality

    International Nuclear Information System (INIS)

    Faris, W.G.

    1976-01-01

    Certain inequalities for unbounded linear operators in L 2 extend to product spaces. This product space property is used to give a new proof that Gross's inequality for matrices implies Nelson's inequality for ordinary differential operators, and that this in turn implies Nelson's inequality for partial differential operators in infinitely many dimensions. A new proof of Gross's inequality is given. There is also a discussion of the physical meaning of Nelson's inequality in quantum field theory. The article may serve as an introduction for non-specialists to some of the recent mathematical work in this subject. (Auth.)

  5. An Initial Topology of Multi-terminal HVDC Transmission System in Europe

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    In this paper, technical challenges for realizing offshore multi-terminal HVDC (MTDC) transmission system in Europe is evaluated. An offshore MTDC topology is projected by interconnecting point-to-point HVDC links with the same voltage level and technology found in south-eastern part of North Sea....... Availability analysis is done to evaluate the feasibility of the proposed offshore MTDC topology. As compared to point-to-point (PtP) HVDC link, MTDC operation gives a more secure and reliable system. This paper shows that the proposed MTDC topology can operate 98.36% of the time....

  6. HVDC Ground Electrodes - a Source of Geophysical Data

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2015-12-01

    The HVDC electrode is a component of a High Voltage Direct Current energy transmission system, and is designed to inject into the ground continuous currents up to 3500 A. The typical HVDC ground electrode is a ring of vertical conductors, 1 km wide, buried a few tens of meters.The design of a HVDC electrode is based on extensive geological, geotechnical and geophysical surveys. Geophysical data are usually electrical (VES) and electromagnetic (TEM/MT) acquisitions, for the modeling of the shallow, near-surface and deep layers of the crust. This survey aims, first, the electrode site selection, and then, at the selected site, this data is combined into a single apparent resistivity curve, which is inverted, allowing for the determination of the layered geoelectric crust model. The injection of electrical continuous current in the electrode is then simulated, with the geoelectric crust model, for the determination of the soil surface potential profile (which is usually asymmetric for different directions, due to non-1D geoelectric models).For the commissioning of a HVDC electrode, field measurements are done, such as electrode grounding resistance, soil surface potentials and metal-to-soil potentials at specific structures (buried pipelines, for instance).The geophysical data acquired during the design phase is a set of data completely independent from the electrical data acquired during the electrode commissioning phase, and both are correlated by the geoelectric model. It happens, therefore, that the geoelectric model can be calibrated based on the electrical data, with the correction of static shifts and other adjustments.This paper suggests that the commissioning of HVDC systems should be associated to a research & development program, with a university or foundation. The idea is to enjoy the opportunity of a more complete field survey, with the acquisition of a wide set of data for a better geological characterization of the area where the electrode was built.

  7. 78 FR 75205 - Death of Nelson Mandela

    Science.gov (United States)

    2013-12-10

    ... of Nelson Mandela By the President of the United States of America Proclamation Today, the United... an inspiration for freedom, justice, and human dignity--Nelson Mandela is no longer with us, he belongs to the ages. Nelson Mandela achieved more than could be expected of any man. His own struggle...

  8. Fundamental study of bulk power HVDC transmission

    International Nuclear Information System (INIS)

    1981-01-01

    Study on the HVDC power transmission have been conducted since 1956. Shinshinano-Frequency Changer had been operated at first on 1977, as our home product, and Hokkaido-Honshu DC transmission also realized at 1979. Research and Development of the bulk power HVDC have been promoted by the UHV transmission special committee in our Institute from 1980. This paper is a comprehensive report published in the parts of operating control, insulation of DC line and countermeasure of fault current, and interferences in order to contribute for planning, design and operating of the UHV DC transmission in future. (author)

  9. A study of offshore wind HVDC system stability and control

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hanchao; Sun, Jian [Rensselaer Polytechnic Institute, Troy, NY (United States). Dept. of Electrical, Computer and Systems Engineering

    2011-07-01

    This work is concerned with the stability and control of ac power collection buses in offshore wind farms with high-voltage dc (HVDC) transmission connection to onshore power grid. The focus of the work is high-frequency interactions among the wind turbines, the ac collection bus and the filters, as well as the HVDC rectifier. Both voltage-source converter and line-commutated converter based HVDC systems are considered. To study high-frequency stability, particularly harmonic resonance in the ac bus, small-signal impedance models are developed for the wind inverters and the HVDC rectifier by using harmonic linearization techniques. An impedance-based stability criterion is applied to assess system stability in both positive- and negative-sequence domain. Small-signal stability conditions and requirements are developed from analytical impedance models. Detailed system-level simulation is used to validated the small-signal analysis. The goal of the study is to develop system design and control techniques that minimize the cost of the offshore infrastructure while guaranteeing system stability and power quality. (orig.)

  10. Generic Models of Wind Turbine Generators for Advanced Applications in a VSC-based Offshore HVDC Network

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Margaris, Ioannis; Hansen, Anca Daniela

    This paper focuses on generic Type 4 wind turbine generators models, their applicability in modern HVDC connections and their capability to provide advanced ancillary services therefrom. A point-to-point HVDC offshore connection is considered. Issues concerning coordinated HVDC and wind farm...... involving the HVDC converters- The performance against frequency disturbances of the two presented configurations is assessed and discussed by means of simulations....

  11. Optimisation of VSC-HVDC Transmission for Wind Power Plants

    DEFF Research Database (Denmark)

    Silva, Rodrigo Da

    Connection of Wind Power Plants (WPP), typically oshore, using VSCHVDC transmission is an emerging solution with many benefits compared to the traditional AC solution, especially concerning the impact on control architecture of the wind farms and the grid. The VSC-HVDC solution is likely to meet...... more stringent grid codes than a conventional AC transmission connection. The purpose of this project is to analyse how HVDC solution, considering the voltage-source converter based technology, for grid connection of large wind power plants can be designed and optimised. By optimisation, the project...... the robust control technique is applied is compared with the classical proportional-integral (PI) performance, by means of time domain simulation in a point-to-point HVDC connection. The three main parameters in the discussion are the wind power delivered from the offshore wind power plant, the variation...

  12. Negative sequence current control in wind power plants with VSC-HVDC connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Teodorescu, Remus; Rodriguez, Pedro

    2012-01-01

    Large offshore wind power plants may have multi-MW wind turbine generators (WTG) equipped with full-scale converters (FSC) and voltage source converter (VSC) based high voltaage direct-current (HVDC) transmission for grid connection. The power electronic converters in theWTG-FSC and the VSC......-HVDC allow fast current control in the offshore grid. This paper presents a method of controlling the negative sequence current injection into the offshore grid from the VSC-HVDC as well as WTG-FSCs. This would minimize the power oscillations and hence reduce the dc voltage overshoots in the VSC-HVDC system...... as well as in the WTG-FSCs; especially when the offshore grid is unbalanced due to asymmetric faults. The formulation for negative sequence current injection is mathematically derived and then implemented in electromagnetic transients (EMT) simulation model. The simulated results show that the negative...

  13. Control strategies for VSC-based HVDC transmission system

    DEFF Research Database (Denmark)

    Stan, Ana-Irina; Stroe, Daniel Ioan; Silva, Rodrigo Da

    2011-01-01

    Throughout this paper the modeling and control of the VSC-based HVDC systems are investigated and described. Two different control methods capable of controlling such systems are proposed. Both developed control strategies are implemented in the dq synchronous reference frame. In order to analyze...... the behavior of the developed VSC-based HVDC transmission system two study cases are carried out using MATLAB/Simulink. The results obtained from simulations show acceptable performances, of the proposed strategies, when changes in the reference parameters are considered. The active power flow between...

  14. Synthesis of a hybrid model of the VSC FACTS devices and HVDC technologies

    Science.gov (United States)

    Borovikov, Yu S.; Gusev, A. S.; Sulaymanov, A. O.; Ufa, R. A.

    2014-10-01

    The motivation of the presented research is based on the need for development of new methods and tools for adequate simulation of FACTS devices and HVDC systems as part of real electric power systems (EPS). The Research object: An alternative hybrid approach for synthesizing VSC-FACTS and -HVDC hybrid model is proposed. The results: the VSC- FACTS and -HVDC hybrid model is designed in accordance with the presented concepts of hybrid simulation. The developed model allows us to carry out adequate simulation in real time of all the processes in HVDC, FACTS devices and EPS as a whole without any decomposition and limitation on their duration, and also use the developed tool for effective solution of a design, operational and research tasks of EPS containing such devices.

  15. Synthesis of a hybrid model of the VSC FACTS devices and HVDC technologies

    International Nuclear Information System (INIS)

    Borovikov, Yu S; Gusev, A S; Sulaymanov, A O; Ufa, R A

    2014-01-01

    The motivation of the presented research is based on the need for development of new methods and tools for adequate simulation of FACTS devices and HVDC systems as part of real electric power systems (EPS). The Research object: An alternative hybrid approach for synthesizing VSC-FACTS and -HVDC hybrid model is proposed. The results: the VSC- FACTS and -HVDC hybrid model is designed in accordance with the presented concepts of hybrid simulation. The developed model allows us to carry out adequate simulation in real time of all the processes in HVDC, FACTS devices and EPS as a whole without any decomposition and limitation on their duration, and also use the developed tool for effective solution of a design, operational and research tasks of EPS containing such devices

  16. Contribution of VSC-HVDC to Frequency Regulation of Power Systems With Offshore Wind Generation

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2015-01-01

    to the onshore system grid through voltage-source converter-based–high voltage direct current (VSC-HVdc) transmission systems. Due to the decoupling of VSC-HVdc and signal transmission delay, offshore wind farms may not be able to respond to the onshore grid frequency excursion in time and, consequently......, the stability and security of the power system will be put at risk, especially for those with high wind penetration. This paper proposes a coordinated control scheme to allow VSC-HVdc link to contribute to the system frequency regulation by adjusting its dc-link voltage. By means of this approach, the dc...... capacitors of VSC-HVdc are controlled to absorb or release energy so as to provide frequency support. To further enhance the system frequency response, the frequency support from VSC-HVdc is also finely coordinated with that from offshore wind farm according to the latency of offshore wind farm responding...

  17. Modelisation et simulation d'une liaison HVDC de type VSC-MMC

    Science.gov (United States)

    Saad, Hani Aziz

    High-voltage direct current transmission systems (HVDC) are rapidly expanding in the world. Two main factors are responsible for this expansion. The first is related to the difficulty of building new overhead lines to ensure the development of high-voltage AC grids, which makes the usage of underground cables more common. However, the use of such cables is limited in length to a few tens of km because of the capacitive current generated by the cable itself. Beyond this length limit, the solution is usually to transmit in DC. The second factor is related to the development of offshore wind power plants that require connecting powers of several hundred of MW to the mainland grid by cables whose lengths can reach several hundreds of km and consequently require HVDC transmission system. Several HVDC projects are currently planned and developed by the French transmission system operator RTE. One of such projects is the INELFE interconnection project, with a capacity of 2,000 MW, between France and Spain. This thesis has been funded by RTE, in order to model and simulate in off-line and real time modes, modern HVDC interconnections. The delivered simulation means are used to examine targeted HVDC system performances and risks of abnormal interactions with surrounding power systems. The particularity of the INELFE HVDC system is the usage of a dedicated control system that will largely determine the dynamic behaviour of the system for both large disturbances (faults on the network) and small perturbations (power step changes). Various VSC topologies, including the conventional two-level, multi-level diode-clamped and floating capacitor multi-level converters, have been proposed and reported in the literature. However, due to the complexity of controls and practical limitations, the VSC-HVDC system installations have been limited to the two-level and three-level diode-clamped converters. Recently, the development of modular technology called MMC (Modular Multilevel

  18. Investigation of multimodule buck–boost inverter-based HVDC transmission system

    Directory of Open Access Journals (Sweden)

    Ahmed A. Elserougi

    2015-01-01

    Full Text Available In high voltage direct current (HVDC systems, the semiconductor devices have to be connected in series to obtain the required high-voltage ratings. This study proposes a new HVDC configuration, namely, multimodule buck–boost inverter for HVDC transmission applications which avoids series connection of large number of semiconductor switches. In addition, it provides a blocking capability against DC side faults. The proposed configuration consists of several simple buck–boost converters which are assembled together to meet the requirements of high-voltage high-power applications. This paper studies the dynamic performance of the proposed system under different operating conditions, and the results were satisfactory. The main advantages of the proposed configuration are: (i pure sinusoidal output which minimises/eliminates the requirements for supplementary AC filters and offers an inherent suppression to the common mode voltages, (ii very low dv/dt stresses and (iii complete blocking capability of AC side contributions during DC side faults. This study discusses the system architecture, passive components selections, voltage and current ratings of its semiconductor devices and the required controllers. A comparison between the proposed configuration and other existing HVDC technologies is also presented in this study.

  19. Coordinated Control Strategies of VSC-HVDC-Based Wind Power Systems for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Xinyin Zhang

    2015-07-01

    Full Text Available The Voltage Source Converter-HVDC (VSC-HVDC system applied to wind power generation can solve large scale wind farm grid-connection and long distance transmission problems. However, the low voltage ride through (LVRT of the VSC-HVDC connected wind farm is a key technology issue that must be solved, and it is currently lacking an economic and effective solution. In this paper, a LVRT coordinated control strategy is proposed for the VSC-HVDC-based wind power system. In this strategy, the operation and control of VSC-HVDC and wind farm during the grid fault period is improved. The VSC-HVDC system not only provides reactive power support to the grid, but also effectively maintains the power balance and DC voltage stability by reducing wind-farm power output, without increasing the equipment investment. Correspondingly, to eliminate the influence on permanent magnet synchronous generator (PMSG-based wind turbine (WT systems, a hierarchical control strategy is designed. The speed and validity of the proposed LVRT coordinated control strategy and hierarchical control strategy were verified by MATLAB/Simulink simulations.

  20. Coordinated system services from offshore wind power plants connected through HVDC networks

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Glasdam, Jakob; Hesselbæk, Bo

    2014-01-01

    This paper presents an overview of power system services in networks involving multiple onshore power systems, a voltage sourced converter (VSC) based high voltage direct current (HVDC) offshore network and an offshore wind power plant (OWPP). A comprehensive list of services regarding onshore...... as well as offshore network operation – both AC and DC – will be discussed from a state of the art perspective. Among them, the most interesting have been selected and will be treated in more detail and the main contribution of this paper will be to shed light on the most relevant aspects related...... to their implementation. For example, new findings on onshore AC voltage control are reported, that help the characterisation of potential AC voltage control that a VSC-HVDC station may offer to an onshore AC grid. The HVDC system behind the VSC-HVDC station may connect, through other converters, to another AC power...

  1. HVDC Ground Electrodes and Tectonic Setting

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2017-12-01

    Ground electrodes in HVDC transmission are huge grounding systems for the DC part of the converter substation, about 1 km wide, sized to inject in the ground DC currents up to 3.5 kA. This work presents an analysis of how the tectonic setting at converter substation location is determinant for the search of the best electrode location (Site Selection) and on its design and performance. It will briefly present the author experience on HVDC electrode design, summarized as follows: Itaipu - Foz do Iguaçu electrodes (transmitter side) located in the middle of Paraná Sedimentary Basin, and Ibiúna electrodes (receiving side) on the border of the basin, 6 km from the geological strike, where the crystalline basement outcrops in São Paulo state; Madeira River - North electrodes (transmitting side) located on the Northwest border of South Amazon Craton, where the crystalline basement is below a shallow sediments layer, and South electrodes (receiving side) located within Paraná Sedimentary Basin; Chile - electrodes located on the Andean forearc, where the Nazca Plate plunges under the South American Plate; Kenya - Ethiopia - electrodes located in the African Rift; Belo Monte - North electrodes (transmitter side) located within the Amazonian Sedimentary Basin, about 35 km of its South border, and South electrodes (receiving side) within Paraná Sedimentary Basin (bipole 1) and on crystalline metamorphic terrain "Brasília Belt" (bipole 2). This diversity of geological conditions results on ground electrodes of different topologies and dimensions, with quite different electrical and thermal performances. A brief study of the geology of the converter stations regions, the so-called Desktop Study, allows for the preview of several important parameters for the site selection and design of the electrodes, such as localization, type, size and estimate of the interference area, which are important predictors of the investment to be made and indications of the design to be

  2. Modeling of HVDC in Dynamic State Estimation Using Unscented Kalman Filter Method

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    HVDC transmission is an integral part of various power system networks. This article presents an Unscented Kalman Filter dynamic state estimator algorithm that considers the presence of HVDC links. The AC - DC power flow analysis, which is implemented as power flow solver for Dynamic State...

  3. The limits of HVDC transmission

    International Nuclear Information System (INIS)

    Pickard, William F.

    2013-01-01

    Renewable energy is abundant, but not necessarily near the urban centers where it will be used. Therefore, it must be transported; and this transport entails a systemic energy penalty. In this paper simple qualitative calculations are introduced to show (i) that high-voltage direct-current (HVDC) power lines for megameter and greater distances are unlikely to achieve power capacities much beyond 2 GW, although they can be paralleled; (ii) that most sources and sinks of electric power are rather less than 10,000 km apart; (iii) that such long lines can be constructed to have transmission losses -tilde 2%; and (iv) that lines of such low loss in fact meet minimal standards of intergenerational equity. - Highlights: • Renewable Energy is abundant, but not necessarily near population centers. • Its transportation requires energy and can be a major systemic inefficiency. • HVDC can be transmitted 10,000 km with 2% loss and near-optimal embodied energy. • Such transmission meets the requirements of intergenerational equity

  4. Voltage Stability Bifurcation Analysis for AC/DC Systems with VSC-HVDC

    Directory of Open Access Journals (Sweden)

    Yanfang Wei

    2013-01-01

    Full Text Available A voltage stability bifurcation analysis approach for modeling AC/DC systems with VSC-HVDC is presented. The steady power model and control modes of VSC-HVDC are briefly presented firstly. Based on the steady model of VSC-HVDC, a new improved sequential iterative power flow algorithm is proposed. Then, by use of continuation power flow algorithm with the new sequential method, the voltage stability bifurcation of the system is discussed. The trace of the P-V curves and the computation of the saddle node bifurcation point of the system can be obtained. At last, the modified IEEE test systems are adopted to illustrate the effectiveness of the proposed method.

  5. Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS

    International Nuclear Information System (INIS)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2012-01-01

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  6. Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of)

    2012-08-15

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  7. Nelson syndrome: historical perspectives and current concepts.

    Science.gov (United States)

    Hornyak, Mark; Weiss, Martin H; Nelson, Don H; Couldwell, William T

    2007-01-01

    The appearance of an adrenocorticotropic hormone (ACTH)-producing tumor after bilateral adrenalectomy for Cushing disease was first described by Nelson in 1958. The syndrome that now bears his name was characterized by hyperpigmentation, a sellar mass, and increased plasma ACTH levels. The treatment of Cushing disease has changed drastically since the 1950s, when the choice was adrenalectomy. Thus, the occurrence, diagnosis, and treatment of Nelson syndrome have changed as well. In the modern era of high-resolution neuroimaging, transsphenoidal microneurosurgery, and stereotactic radiosurgery, Nelson syndrome has become a rare entity. The authors describe the history of the diagnosis and treatment of Nelson syndrome. In light of the changes described, the authors believe this disease must be reevaluated in the contemporary era and a modern paradigm adopted.

  8. HVDC power transmission environmental issues review

    International Nuclear Information System (INIS)

    Bailey, W.H.; Weil, D.E.; Stewart, J.R.

    1997-04-01

    This report strives to define the various environmental effects associated with HVDC lines, discusses the current knowledge of their potential effects on biological and non-biological systems, and compares these effects associated with ac lines where appropriate

  9. HVDC power transmission environmental issues review

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, W.H.; Weil, D.E. [Bailey Research Associates, Inc., New York, NY (United States); Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States)

    1997-04-01

    This report strives to define the various environmental effects associated with HVDC lines, discusses the current knowledge of their potential effects on biological and non-biological systems, and compares these effects associated with ac lines where appropriate.

  10. Simulative Study into the Development of a Hybrid HVDC System Through a Comparative Research with HVAC: a Futuristic Approach

    Directory of Open Access Journals (Sweden)

    R. S. Narayan

    2017-06-01

    Full Text Available High Voltage Direct Current Transmission (HVDC is considered a better solution for bulk long distance transmissions. The increased use of HVDC is a result of its advantages over the HVAC systems and especially of its fault stability nature. A better solution is proposed by using a Voltage Source Controlled–HVDC as one of the infeed for the Multi-Infeed HVDC (MIDC or MI-HVDC systems. The main advantage with the VSC converter is its flexible power control which enhances the stability of the MIDC systems. In this paper, the behavior of an HVDC system is compared with that of an HVAC during faults. A Hybrid HVDC system that includes a LCC as a rectifier unit and a VSC converter as the inverter is being proposed. It is considered suitable for MIDC systems and particularly for supplying a weak AC system. The performance of the system during steady state and transient conditions for all the proposed topologies including HVDC, HVAC and Hybrid HVDC are studied in MATLAB/SIMULINK. All of the proposed control strategies are evaluated via a series of simulation case studies.

  11. Design, control and application of modular multilevel converters for HVDC transmission systems

    CERN Document Server

    Sharifabadi, Kamran; Nee, Hans-Peter; Norrga, Staffan; Teodorescu, Remus

    2016-01-01

    Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical and economic requirements and optimization options, fault management, dynamic and transient stability. Finally, the third chapter explores the applications of MMC in HVDC transmission and Multi Terminal configurations, including Supergrids.

  12. HVDC-System-Interaction Assessment through Line-Flow Change-Distribution Factor and Transient-Stability Analysis at Planning Stage

    Directory of Open Access Journals (Sweden)

    Sungchul Hwang

    2016-12-01

    Full Text Available Many of the recent projects for new transmission line have considered the high-voltage direct current (HVDC system, owing to the many advantages of the direct current (DC system. The most noteworthy advantage is that a cable can serve as a substitute for the overhead transmission line in residential areas; therefore, the HVDC system application is increasing, and as the number of DC systems in the power system increases, the interaction assessment regarding the HVDC system gains importance. An index named multi-infeed interaction factor (MIIF is commonly used to estimate the interaction between power converters; however, the HVDC system is composed of two converters and a transmission line. The MIIF represents the interaction between the rectifiers and inverters, but not for the whole system. In this work, a method to assess the interaction of the whole system was therefore studied. To decide on the location of the new HVDC transmission system at the planning stage, in consideration of the interaction of the existing DC system, the line flow change distribution factor, according to the HVDC-transmission capacity change, was examined. Also, a power system transient -stability analysis was performed with different HVDC system locations, depending on the distribution factor. The simulation results indicate that when the factor is higher, two HVDC systems have a stronger interaction and are less stable in the transient state.

  13. OPF-Based Optimal Location of Two Systems Two Terminal HVDC to Power System Optimal Operation

    Directory of Open Access Journals (Sweden)

    Mehdi Abolfazli

    2013-04-01

    Full Text Available In this paper a suitable mathematical model of the two terminal HVDC system is provided for optimal power flow (OPF and optimal location based on OPF such power injection model. The ability of voltage source converter (VSC-based HVDC to independently control active and reactive power is well represented by the model. The model is used to develop an OPF-based optimal location algorithm of two systems two terminal HVDC to minimize the total fuel cost and active power losses as objective function. The optimization framework is modeled as non-linear programming (NLP and solved by Matlab and GAMS softwares. The proposed algorithm is implemented on the IEEE 14- and 30-bus test systems. The simulation results show ability of two systems two terminal HVDC in improving the power system operation. Furthermore, two systems two terminal HVDC is compared by PST and OUPFC in the power system operation from economical and technical aspects.

  14. Analysis of control alternatives for offshore wind farms connected through a VSC-HVDC link

    Energy Technology Data Exchange (ETDEWEB)

    Belenguer, Enrique; Vidal, Ricardo; Beltran, Hector [Jaume I Univ., Castellon de la Plana (Spain). Dept. of Industrial Engineering Systems; Blasco-Gimenez, Ramon [Univ. Politecnica de Valencia (Spain). Dept. of Systems Engineering and Control

    2012-07-01

    The use of VSC-HVDC transmission systems for the connection of offshore wind power plants increases the control capabilities of the whole system with respect to the use of standard LCC-HVDC systems. In this paper two different control strategies for an offshore wind farm connected through a VSC-HVDC link have been developed and analyzed through PSCAD simulations. Both, steady state and transient behavior have been simulated in order to find the best control strategy for such a system. (orig.)

  15. A novel power control strategy of Modular Multi-level Converter in HVDC-AC hybrid transmission systems for passive networks

    DEFF Research Database (Denmark)

    Hu, Zhenda; Wu, Rui; Yang, Xiaodong

    2014-01-01

    With the development of High Voltage DC Transmission (HVDC) technology, there will be more and more HVDC-AC hybrid transmission system in the world. A basic challenge in HVDC-AC hybrid transmission systems is to optimize the power sharing between DC and AC lines, which become more severe when sup...... control strategy of Modular Multi-level Converter in VSC-HVDC, which can optimize converter output power according to passive network loading variation. Proposal method is studied with a case study of a VSC-HVDC AC hybrid project by PSCAD/EMTDC simulations....

  16. Site Selection for Hvdc Ground Electrodes

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2014-12-01

    High-Voltage Direct Current (HVDC) transmission systems are composed of a bipole transmission line with a converter substation at each end. Each substation may be equipped with a HVDC ground electrode, which is a wide area (up to 1 km Ø) and deep (from 3 to 100m) electrical grounding. When in normal operation, the ground electrode will dissipate in the soil the unbalance of the bipole (~1.5% of the rated current). When in monopolar operation with ground return, the HVDC electrode will inject in the soil the nominal pole continuous current, of about 2000 to 3000 Amperes, continuously for a period up to a few hours. HVDC ground electrodes site selection is a work based on extensive geophysical and geological surveys, in order to attend the desired design requirements established for the electrodes, considering both its operational conditions (maximum soil temperature, working life, local soil voltage gradients etc.) and the interference effects on the installations located up to 50 km away. This poster presents the geophysical investigations conducted primarily for the electrodes site selection, and subsequently for the development of the crust resistivity model, which will be used for the interference studies. A preliminary site selection is conducted, based on general geographical and geological criteria. Subsequently, the geology of each chosen area is surveyed in detail, by means of electromagnetic/electrical geophysical techniques, such as magnetotelluric (deep), TDEM (near-surface) and electroresistivity (shallow). Other complementary geologic and geotechnical surveys are conducted, such as wells drilling (for geotechnical characterization, measurement of the water table depth and water flow, and electromagnetic profiling), and soil and water sampling (for measurement of thermal parameters and evaluation of electrosmosis risk). The site evaluation is a dynamic process along the surveys, and some sites will be discarded. For the two or three final sites, the

  17. Stabilising system frequency using HVDC between the Continental European, Nordic, and Great Britain systems

    NARCIS (Netherlands)

    de Haan, J.E.S.; Escudero Concha, C.; Gibescu, M.; van Putten, J.; Doorman, G.L.; Kling, W.L.

    2016-01-01

    For future efficiency improvement of the frequency containment process (primary control) within European power systems, cooperation between (multiple) synchronous areas using their controllable HVDC interconnections is optioned. However, the differences in system size, HVDC interconnection capacity,

  18. Mitigation of commutation failures in LCC–HVDC systems based on superconducting fault current limiters

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr

    2016-11-15

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC–HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC–HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC–HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC–HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  19. Mitigation of commutation failures in LCC–HVDC systems based on superconducting fault current limiters

    International Nuclear Information System (INIS)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook

    2016-01-01

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC–HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC–HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC–HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC–HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  20. Mitigation of commutation failures in LCC-HVDC systems based on superconducting fault current limiters

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook

    2016-11-01

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC-HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC-HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC-HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC-HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  1. Impact of Offshore Wind Power Integrated by VSC-HVDC on Power Angle Stability of Power Systems

    Science.gov (United States)

    Lu, Haiyang; Tang, Xisheng

    2017-05-01

    Offshore wind farm connected to grid by VSC-HVDC loses frequency support for power system, so adding frequency control in wind farm and VSC-HVDC system is an effective measure, but it will change wind farm VSC-HVDC’s transient stability on power system. Through theoretical analysis, concluding the relationship between equivalent mechanical power and electromagnetic power of two-machine system with the active power of wind farm VSC-HVDC, then analyzing the impact of wind farm VSC-HVDC with or without frequency control and different frequency control parameters on angle stability of synchronous machine by EEAC. The validity of theoretical analysis has been demonstrated through simulation in PSCAD/EMTDC.

  2. HVDC Transmission an Outlook and Significance for Pakistani Power Sector

    Science.gov (United States)

    Ahmad, Muhammad; Wang, Zhixin; Wang, Jinjian; Baloach, Mazhar H.; Longxin, Bao; Hua, Qing

    2018-04-01

    Recently a paradigm shift in the power sector is observed, i.e., countries across the globe have deviated their attention to distributed generation rather than conventional centralized bulk generation. Owing to the above narrative, distributed energy resources e.g., wind and PV have gained the adequate attention of governments and researchers courtesy to their eco-friendly nature. On the contrary, the increased infiltration of distributed generation to the power system has introduced many technical and economical glitches such as long-distance transmission, transmission lines efficiency, control capability and cost etc. To mitigate these complications, the utility of high voltage direct current (HVDC) transmission has emerged as a possible solution. In this context, this paper includes a brief discussion on the fundamentals HVDC and its significance in Pakistani power sector. Furthermore, the potential of distributed energy resources for Pakistan is also the subject matter of this paper, so that significance of HVDC transmission can effectively be deliberated.

  3. Stability of DC Voltage Droop Controllers in VSC HVDC Systems

    DEFF Research Database (Denmark)

    Thams, Florian; Suul, Jon Are; D’Arco, Salvatore

    2015-01-01

    Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC-based conver......Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC...

  4. Government support for hvdc research

    Energy Technology Data Exchange (ETDEWEB)

    1968-07-12

    To help secure a place for Britain in hvdc export market beyond the next decade, the Ministry of Technology is sponsoring. Research into thyristor converters as a replacement for the mercury arc valves now used in terminal equipment. English Electric has secured from Mintech a risk sharing contract contributing nearly 250,000 pounds towards the cost of a development program.

  5. Nelson-Farrar cost indexes

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper discusses the Nelson-Farrar Cost Indexs. Topics covered include: economic analysis, petroleum refineries, petroleum industry, pumps, compressors, beat exchangers, cost estimation, productivity and wages

  6. Transporte de energía eléctrica en corriente contínua. Enlaces HVDC-VSC

    OpenAIRE

    Monterrubio Díez, Mario

    2013-01-01

    El proyecto fin de carrera se plantea como un estudio de la tecnología HVDC-VSC, por su carácter novedoso y reciente implantación en los sistemas de transporte de electricidad. Con este trabajo se pretende dar a conocer de modo general la tecnología HVDC y de manera particular la variante HVDC-VSC. Departamento de Ingeniería Eléctrica Ingeniero Técnico Industrial, Especialidad en Electricidad

  7. Reliability analysis of HVDC grid combined with power flow simulations

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yongtao; Langeland, Tore; Solvik, Johan [DNV AS, Hoevik (Norway); Stewart, Emma [DNV KEMA, Camino Ramon, CA (United States)

    2012-07-01

    Based on a DC grid power flow solver and the proposed GEIR, we carried out reliability analysis for a HVDC grid test system proposed by CIGRE working group B4-58, where the failure statistics are collected from literature survey. The proposed methodology is used to evaluate the impact of converter configuration on the overall reliability performance of the HVDC grid, where the symmetrical monopole configuration is compared with the bipole with metallic return wire configuration. The results quantify the improvement on reliability by using the later alternative. (orig.)

  8. Evaluation of HVDC interconnection models for considering its impact in real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Lund, P.

    2015-01-01

    An approach to evaluate the HVDC interconnectionsmodels to be used in real-time voltage stability assessment is proposed.The existing models for the HVDC interconnections, thatare based on voltage source converter, were studied selecting theones that are suitable for its application in Thevenin...... equivalent ´methods for voltage stability assessment. The proposed methodis to evaluate the validity of the models by using synthetizedPMU measurements from simulations and from PMUs connectedto the danish system. Wide-area measurements are used toestimate the HVDC model parameters which are needed...

  9. Voltage-current characteristics of multiterminal HVDC-VSC for offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Gomis-Bellmunt, Oriol [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2., 08028 Barcelona (Spain); IREC Catalonia Institute for Energy Research, Barcelona (Spain); Liang, Jun; Ekanayake, Janaka; Jenkins, Nicholas [School of Engineering, Cardiff University, Queen' s Buildings, The Parade, Cardiff CF24 3AA, Wales (United Kingdom)

    2011-02-15

    Voltage-current characteristics and equilibrium points for the DC voltages of multiterminal HVDC systems using voltage source converters are discussed. The wind farm rectifiers and grid connected inverters are analyzed through their operating modes, governing equations and graphical characteristics. Using the converter equations and the HVDC grid conductance matrix the equilibrium voltages and currents are found. Case studies are presented considering wind power generation, loss of a converter and voltage sags in the AC grid. (author)

  10. Feasibility analysis of a novel hybrid-type superconducting circuit breaker in multi-terminal HVDC networks

    Science.gov (United States)

    Khan, Umer Amir; Lee, Jong-Geon; Seo, In-Jin; Amir, Faisal; Lee, Bang-Wook

    2015-11-01

    Voltage source converter-based HVDC systems (VSC-HVDC) are a better alternative than conventional thyristor-based HVDC systems, especially for developing multi-terminal HVDC systems (MTDC). However, one of the key obstacles in developing MTDC is the absence of an adequate protection system that can quickly detect faults, locate the faulty line and trip the HVDC circuit breakers (DCCBs) to interrupt the DC fault current. In this paper, a novel hybrid-type superconducting circuit breaker (SDCCB) is proposed and feasibility analyses of its application in MTDC are presented. The SDCCB has a superconducting fault current limiter (SFCL) located in the main current path to limit fault currents until the final trip signal is received. After the trip signal the IGBT located in the main line commutates the current into a parallel line where DC current is forced to zero by the combination of IGBTs and surge arresters. Fault simulations for three-, four- and five-terminal MTDC were performed and SDCCB performance was evaluated in these MTDC. Passive current limitation by SFCL caused a significant reduction of fault current interruption stress in the SDCCB. It was observed that the DC current could change direction in MTDC after a fault and the SDCCB was modified to break the DC current in both the forward and reverse directions. The simulation results suggest that the proposed SDCCB could successfully suppress the DC fault current, cause a timely interruption, and isolate the faulty HVDC line in MTDC.

  11. Offshore Wind Farms and HVDC Grids Modeling as a Feedback Control System for Stability Analysis

    DEFF Research Database (Denmark)

    Bidadfar, Ali; Saborío-Romano, Oscar; Altin, Müfit

    The low impedance characteristics of DC transmission lines cause the voltage source converter (VSC) in HVDC networks to become electrically closer together and increase the risk of severe interactions between the converters. Such interactions, in turn, intensify the implementation of the grid...... control schemes and may lead the entire system to instability. Assessing the stability and adopting complex coordinated control schemes in an HVDC grid and wind farm turbines are challenging and require a precise model of the HVDC grid, wind farm, and the controllers. In this paper, a linear multivariable...... feedback control system (FCS) model is proposed to represent the dynamic characteristics of HVDC grids and their controllers. The FCS model can be used for different dynamic analyses in time and frequency domains. Moreover, using the FCS model the system stability is analyzed in both open- and closed...

  12. Coordinated Control Strategies for Offshore Wind Farm Integration via VSC-HVDC for System Frequency Support

    DEFF Research Database (Denmark)

    Li, Yujun; Xu, Zhao; Østergaard, Jacob

    2017-01-01

    Coordinated control strategies to provide system inertia support for main grid from offshore wind farm that is integrated through HVdc transmission is the subject matter of this paper. The strategy that seeks to provide inertia support to the main grid through simultaneous utilization of HVdc...... capacitors energy, and wind turbines (WTs) inertia without installing the remote communication of two HVdc terminals is introduced in details. Consequently, a novel strategy is proposed to improve system inertia through sequentially exerting dc capacitors energy and then WTs inertia via a cascading control...

  13. Determining optimal stations for HVDC terminals; Ermittlung vorteilhafter HGUe-Anschluss knoten

    Energy Technology Data Exchange (ETDEWEB)

    Linnemann, C.; Echternacht, D.; Breuer, C.; Heuberger, D.; Moser, A. [RWTH Aachen (Germany). Inst. fuer Elektrische Anlagen und Energiewirtschaft (IAEW)

    2012-07-01

    Due to a massiv increase in renewable generation capacity the need for grid reinforcements in the European transmission grid is rising significantly. The nuclear phase out in Germany enlarges this effect furthermore. The required transmission capacity can be provided using conventional AC equipment but also the usage of HVDC technology is currently discussed. This paper presents an approach for identifying suitable locations for HVDc terminals. Subsequently the approach is applied to a model of the German transmission network in the year 2022. (orig.)

  14. DC breakdown characteristics of silicone polymer composites for HVDC insulator applications

    Science.gov (United States)

    Han, Byung-Jo; Seo, In-Jin; Seong, Jae-Kyu; Hwang, Young-Ho; Yang, Hai-Won

    2015-11-01

    Critical components for HVDC transmission systems are polymer insulators, which have stricter requirements that are more difficult to achieve compared to those of HVAC insulators. In this study, we investigated the optimal design of HVDC polymer insulators by using a DC electric field analysis and experiments. The physical properties of the polymer specimens were analyzed to develop an optimal HVDC polymer material, and four polymer specimens were prepared for DC breakdown experiments. Single and reverse polarity breakdown tests were conducted to analyze the effect of temperature on the breakdown strength of the polymer. In addition, electric fields were analyzed via simulations, in which a small-scale polymer insulator model was applied to prevent dielectric breakdown due to electric field concentration, with four DC operating conditions taken into consideration. The experimental results show that the electrical breakdown strength and the electric field distribution exhibit significant differences in relation to different DC polarity transition procedures.

  15. Nelson`s syndrome associated with a somatic frame shift mutation in the glucocorticoid recepter gene

    Energy Technology Data Exchange (ETDEWEB)

    Karl, M.; Stratakis, C.A.; Chrousos, G.P.; Katz, D.A.; Ali, I.U.; Oldfield, E.H. [National Inst. of Neurological Disorders and Stroke, Bethesda, MD (United States)] [and others

    1996-01-01

    Nelson`s syndrome is the appearance and/or progression of ACTH-secreting pituitary macroadenomas in patients who had previously undergone bilateral adrenalectomy for Cushing`s disease. Extremely high plasma ACTH levels and aggressive neoplastic growth might be explained by the lack of appropriate glucocorticoid negative feedback due to defective glucocorticoid signal transduction. To study the glucocorticoid receptor (GR) gene in Nelson`s syndrome, DNA was extracted from pituitary adenomas and leukocytes of four patients with this condition and amplified by PCR for direct sequence analysis. In one of the tumors, a heterozygous mutation, consisting of an insertion of a thymine between complementary DNA nucleotides 1188 and 1189, was found in exon 2. This frame-shift mutation led to premature termination at amino acid residue 366 of the world-type coding sequence, excluding the expression of a functioning receptor protein from the defective allele. The mutation was not detected in the sequence of the GR gene in the patient`s leukocyte DNA, indicating a somatic origin. By lowering the receptor number in tumorous cells, this defect might have caused local resistance to negative glucocorticoid feedback similar to that caused by the presence of a null allele in a kindred with the generalized glucocorticoid resistance syndrome. P53 protein accumulation, previously reported in 60% of corticotropinomas, could not be detected in any of the four pituitary tumors examined by immunohistochemistry. We suggest that a somatic GR defect might have played a pathophysiological role in the tumorigenesis of the corticotropinoma bearing this mutation. 35 refs., 3 figs., 1 tab.

  16. Debating the Social Thinking of Carlos Nelson Coutinho

    Directory of Open Access Journals (Sweden)

    Bruno Bruziguessi

    2017-10-01

    Full Text Available BRAZ, Marcelo; RODRIGUES, Mavi (Org.. Cultura, democracia e socialismo: as idéias de Carlos Nelson Coutinho em debate. [Culture, democracy and socialism: The ideas of Carlos Nelson Coutinho in debate]. Rio de Janeiro: Mórula, 2016. 248 p.

  17. Total Magnetic Field Signatures over Submarine HVDC Power Cables

    Science.gov (United States)

    Johnson, R. M.; Tchernychev, M.; Johnston, J. M.; Tryggestad, J.

    2013-12-01

    Mikhail Tchernychev, Geometrics, Inc. Ross Johnson, Geometrics, Inc. Jeff Johnston, Geometrics, Inc. High Voltage Direct Current (HVDC) technology is widely used to transmit electrical power over considerable distances using submarine cables. The most commonly known examples are the HVDC cable between Italy and Greece (160 km), Victoria-Tasmania (300 km), New Jersey - Long Island (82 km) and the Transbay cable (Pittsburg, California - San-Francisco). These cables are inspected periodically and their location and burial depth verified. This inspection applies to live and idle cables; in particular a survey company could be required to locate pieces of a dead cable for subsequent removal from the sea floor. Most HVDC cables produce a constant magnetic field; therefore one of the possible survey tools would be Marine Total Field Magnetometer. We present mathematical expressions of the expected magnetic fields and compare them with fields observed during actual surveys. We also compare these anomalies fields with magnetic fields produced by other long objects, such as submarine pipelines The data processing techniques are discussed. There include the use of Analytic Signal and direct modeling of Total Magnetic Field. The Analytic Signal analysis can be adapted using ground truth where available, but the total field allows better discrimination of the cable parameters, in particular to distinguish between live and idle cable. Use of a Transverse Gradiometer (TVG) allows for easy discrimination between cable and pipe line objects. Considerable magnetic gradient is present in the case of a pipeline whereas there is less gradient for the DC power cable. Thus the TVG is used to validate assumptions made during the data interpretation process. Data obtained during the TVG surveys suggest that the magnetic field of a live HVDC cable is described by an expression for two infinite long wires carrying current in opposite directions.

  18. Advanced solutions in power systems HVDC, facts, and artificial intelligence

    CERN Document Server

    Liu, Chen-Ching; Edris, Abdel-Aty

    2016-01-01

    Provides insight on both classical means and new trends in the application of power electronic and artificial intelligence techniques in power system operation and control This book presents advanced solutions for power system controllability improvement, transmission capability enhancement and operation planning. The book is organized into three parts. The first part describes the CSC-HVDC and VSC-HVDC technologies, the second part presents the FACTS devices, and the third part refers to the artificial intelligence techniques. All technologies and tools approached in this book are essential for power system development to comply with the smart grid requirements.

  19. Power system analysis of Hanlim superconducting HVDC system using real time digital simulator

    International Nuclear Information System (INIS)

    Won, Y.J.; Kim, J.G.; Kim, A.R.; Kim, G.H.; Park, M.; Yu, I.K.; Sim, K.D.; Cho, J.; Lee, S.; Jeong, K.W.; Watanabe, K.

    2011-01-01

    KEPCO has planned to construct a test site for renewable energy in Jeju power system. One kilometer length of total 8 km was designed as superconducting DC cable. We have developed a simulation model of the 8 km HVDC system using real time digital simulator. The simulation result shows that the HVDC line was not affected by wind power variation. Jeju island is located approximately 100 km south from the mainland of Korea, and had a peak load of about 553 MW in 2008. The demand increases 7.2% a year over the last 5 years. Since the wind profiles of Jeju island are more favorable than mainland of Korea, many companies have shown interest in the wind power business at the Jeju island. Moreover KEPCO has a plan for renewable energy test too whose power will be delivered by HVDC system. One kilometer length of total 8 km was designed as superconducting DC cable. Rest 7 km will be the conventional overhead line. In this paper, the authors have developed a simulation model of the power network around 8 km HVDC system using real time digital simulator (RTDS).

  20. An Assessment of Converter Modelling Needs for Offshore Wind Power Plants Connected via VSC-HVDC Networks

    DEFF Research Database (Denmark)

    Glasdam, Jakob; Zeni, Lorenzo; Hjerrild, Jesper

    2013-01-01

    Modular multilevel cascaded converter (MMCC) based high voltage direct current (HVDC) transmission is technically superior to other technologies, especially in case of connection of offshore wind power plants (OWPPs). Modelling challenges are faced by OWPP developers, who are not acquainted...... with detailed information regarding the internal behaviour of such complex devices. This paper presents an investigation of the modelling requirements of the MMCC HVDC system, based on comparison between simulation results using a detailed HVDC representation in PSCAD/EMTDC and two less detailed models realised...

  1. DC power flow control for radial offshore multi-terminal HVDC transmission system by considering steady-state DC voltage operation range

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    This paper deals with a radial offshore multi-terminal HVDC (MTDC) transmission system which is formed by interconnection several existing offshore wind farm (OWF) HVDC links with a shore-to-shore (StS) HVDC link. A challenge arises when deciding the steady-state DC voltage operating level...

  2. Power for southern Italy: hvdc Sardinia to mainland 200 MW scheme now commissioned

    Energy Technology Data Exchange (ETDEWEB)

    1967-02-16

    Transmission of the maximum rated power of 200 MW over the hvdc system which now links Sardinia with the Italian Mainland marks the successful completion of a notable British Export contract by English Electric. The link was commissioned on February 1. The Sardinia scheme is the seventh hvdc scheme to be completed in the world and is the first to be engineered by submarine cable.

  3. Meet EPA's Dan Nelson

    Science.gov (United States)

    EPA’s Dan Nelson is the Director of the Human Research Protocol Office at the National Health and Environmental Effect Research Laboratory, Dan works to protect the rights and welfare of EPA’s research participants.

  4. Operational characteristics analysis of a 8 mH class HTS DC reactor for an LCC type HVDC system

    International Nuclear Information System (INIS)

    Kim, S. K.; Go, B. S.; Dinh, M. C.; Park, M.; Yu, I. K.; Kim, J. H.

    2015-01-01

    Many kinds of high temperature superconducting (HTS) devices are being developed due to its several advantages. In particular, the advantages of HTS devices are maximized under the DC condition. A line commutated converter (LCC) type high voltage direct current (HVDC) transmission system requires large capacity of DC reactors to protect the converters from faults. However, conventional DC reactor made of copper causes a lot of electrical losses. Thus, it is being attempted to apply the HTS DC reactor to an HVDC transmission system. The authors have developed a 8 mH class HTS DC reactor and a model-sized LCC type HVDC system. The HTS DC reactor was operated to analyze its operational characteristics in connection with the HVDC system. The voltage at both ends of the HTS DC reactor was measured to investigate the stability of the reactor. The voltages and currents at the AC and DC side of the system were measured to confirm the influence of the HTS DC reactor on the system. Two 5 mH copper DC reactors were connected to the HVDC system and investigated to compare the operational characteristics. In this paper, the operational characteristics of the HVDC system with the HTS DC reactor according to firing angle are described. The voltage and current characteristics of the system according to the types of DC reactors and harmonic characteristics are analyzed. Through the results, the applicability of an HTS DC reactor in an HVDC system is confirmed

  5. Operational characteristics analysis of a 8 mH class HTS DC reactor for an LCC type HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. K.; Go, B. S.; Dinh, M. C.; Park, M.; Yu, I. K. [Changwon National University, Changwon (Korea, Republic of); Kim, J. H. [Daejeon University, Daejeon (Korea, Republic of)

    2015-03-15

    Many kinds of high temperature superconducting (HTS) devices are being developed due to its several advantages. In particular, the advantages of HTS devices are maximized under the DC condition. A line commutated converter (LCC) type high voltage direct current (HVDC) transmission system requires large capacity of DC reactors to protect the converters from faults. However, conventional DC reactor made of copper causes a lot of electrical losses. Thus, it is being attempted to apply the HTS DC reactor to an HVDC transmission system. The authors have developed a 8 mH class HTS DC reactor and a model-sized LCC type HVDC system. The HTS DC reactor was operated to analyze its operational characteristics in connection with the HVDC system. The voltage at both ends of the HTS DC reactor was measured to investigate the stability of the reactor. The voltages and currents at the AC and DC side of the system were measured to confirm the influence of the HTS DC reactor on the system. Two 5 mH copper DC reactors were connected to the HVDC system and investigated to compare the operational characteristics. In this paper, the operational characteristics of the HVDC system with the HTS DC reactor according to firing angle are described. The voltage and current characteristics of the system according to the types of DC reactors and harmonic characteristics are analyzed. Through the results, the applicability of an HTS DC reactor in an HVDC system is confirmed.

  6. Feasibility analysis of a novel hybrid-type superconducting circuit breaker in multi-terminal HVDC networks

    International Nuclear Information System (INIS)

    Khan, Umer Amir; Lee, Jong-Geon; Seo, In-Jin; Amir, Faisal; Lee, Bang-Wook

    2015-01-01

    Highlights: • A novel hybrid-type superconducting circuit breaker (SDCCB) is proposed. • SDCCB has SFCL located in the main current path to limit the fault current until the final trip signal. • SFCL in SDCCB suppressed the fast rising DC fault current for a predefined time. • SFCL significantly reduced the DC current breaking stress on SDCCB components. • SDCCB isolated the HVDC faulty line in three, four, and five converter stations MTDC. - Abstract: Voltage source converter-based HVDC systems (VSC-HVDC) are a better alternative than conventional thyristor-based HVDC systems, especially for developing multi-terminal HVDC systems (MTDC). However, one of the key obstacles in developing MTDC is the absence of an adequate protection system that can quickly detect faults, locate the faulty line and trip the HVDC circuit breakers (DCCBs) to interrupt the DC fault current. In this paper, a novel hybrid-type superconducting circuit breaker (SDCCB) is proposed and feasibility analyses of its application in MTDC are presented. The SDCCB has a superconducting fault current limiter (SFCL) located in the main current path to limit fault currents until the final trip signal is received. After the trip signal the IGBT located in the main line commutates the current into a parallel line where DC current is forced to zero by the combination of IGBTs and surge arresters. Fault simulations for three-, four- and five-terminal MTDC were performed and SDCCB performance was evaluated in these MTDC. Passive current limitation by SFCL caused a significant reduction of fault current interruption stress in the SDCCB. It was observed that the DC current could change direction in MTDC after a fault and the SDCCB was modified to break the DC current in both the forward and reverse directions. The simulation results suggest that the proposed SDCCB could successfully suppress the DC fault current, cause a timely interruption, and isolate the faulty HVDC line in MTDC.

  7. Feasibility analysis of a novel hybrid-type superconducting circuit breaker in multi-terminal HVDC networks

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Umer Amir [Hanyang University, Sa-3dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of); National University of Sciences and Technology, PNEC Campus, Habib Rehmatullah Road, Karachi (Pakistan); Lee, Jong-Geon; Seo, In-Jin [Hanyang University, Sa-3dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of); Amir, Faisal [National University of Sciences and Technology, PNEC Campus, Habib Rehmatullah Road, Karachi (Pakistan); Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr [Hanyang University, Sa-3dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of)

    2015-11-15

    Highlights: • A novel hybrid-type superconducting circuit breaker (SDCCB) is proposed. • SDCCB has SFCL located in the main current path to limit the fault current until the final trip signal. • SFCL in SDCCB suppressed the fast rising DC fault current for a predefined time. • SFCL significantly reduced the DC current breaking stress on SDCCB components. • SDCCB isolated the HVDC faulty line in three, four, and five converter stations MTDC. - Abstract: Voltage source converter-based HVDC systems (VSC-HVDC) are a better alternative than conventional thyristor-based HVDC systems, especially for developing multi-terminal HVDC systems (MTDC). However, one of the key obstacles in developing MTDC is the absence of an adequate protection system that can quickly detect faults, locate the faulty line and trip the HVDC circuit breakers (DCCBs) to interrupt the DC fault current. In this paper, a novel hybrid-type superconducting circuit breaker (SDCCB) is proposed and feasibility analyses of its application in MTDC are presented. The SDCCB has a superconducting fault current limiter (SFCL) located in the main current path to limit fault currents until the final trip signal is received. After the trip signal the IGBT located in the main line commutates the current into a parallel line where DC current is forced to zero by the combination of IGBTs and surge arresters. Fault simulations for three-, four- and five-terminal MTDC were performed and SDCCB performance was evaluated in these MTDC. Passive current limitation by SFCL caused a significant reduction of fault current interruption stress in the SDCCB. It was observed that the DC current could change direction in MTDC after a fault and the SDCCB was modified to break the DC current in both the forward and reverse directions. The simulation results suggest that the proposed SDCCB could successfully suppress the DC fault current, cause a timely interruption, and isolate the faulty HVDC line in MTDC.

  8. Reprint of “Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS”

    International Nuclear Information System (INIS)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2013-01-01

    Highlights: ► A model-sized superconducting VSC-HVDC system was designed and fabricated. ► A real-time simulation using Real Time Digital Simulator has been performed. ► The AC loss characteristics of HTS DC power cable caused by harmonics were analyzed. ► The AC loss of the HTS DC power cable will be used as a parameter to design the cable cooling system. -- Abstract: The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail

  9. Reprint of “Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS”

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of)

    2013-01-15

    Highlights: ► A model-sized superconducting VSC-HVDC system was designed and fabricated. ► A real-time simulation using Real Time Digital Simulator has been performed. ► The AC loss characteristics of HTS DC power cable caused by harmonics were analyzed. ► The AC loss of the HTS DC power cable will be used as a parameter to design the cable cooling system. -- Abstract: The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  10. Steady-state operational range evolution from a two-terminal to a multiterminal HVDC transmission system

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    DC grids are anticipated to grow organically with one possible initial configuration being formed by interconnecting an additional HVDC converter into an existing shore-to-shore (StS) HVDC link. In order to ensure the performance of this MTDC system, the DC voltage at each converter terminal within...

  11. Power-Hardware-In-the-Loop (PHIL) Test of VSC-based HVDC connection for Offshore Wind Power Plants (WPPs)

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Cha, Seung-Tae; Wu, Qiuwei

    2011-01-01

    This paper presents a power-hardware-in-the-loop (PHIL) test for an offshore wind power plant (WPP) interconnected to the onshore grid by a VSC-based HVDC connection. The intention of the PHIL test is to verify the control coordination between the plant side converter of the HVDC connection...... the successful control coordination between the WPP and the plant side VSC converter of the HVDC connection of the WPP....

  12. Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Sharifabadi, Kamran; Harnefors, Lennart; Nee, Hans-Peter

    distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical......Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three...

  13. A new look at Bell's inequalities and Nelson's theorem

    International Nuclear Information System (INIS)

    Schulz, B.

    2009-01-01

    In 1985, Edward Nelson, who formulated the theory of stochastic mechanics, made an interesting remark about Bell's theorem. Nelson analysed the latter in the light of classical fields that behave randomly. He found that if a stochastic hidden variable theory fulfils certain conditions, the inequality of Bell can be violated. Moreover, Nelson was able to prove that this may happen without any instantaneous communication between the two spatially separated measurement stations. Since Nelson's article got almost overlooked by physicists, we try to review his comments on the theorem. We argue that a modification of stochastic mechanics published recently by Fritsche and Haugk can be extended to a theory which fulfils the requirements of Nelson's analysis. The article proceeds to derive the quantum mechanical formalism of spinning particles and the Pauli equation from this version of stochastic mechanics. Then, we investigate Bohm's version of the EPR experiment. Additionally, other setups, like entanglement swapping or time and position correlations, are shortly explained from the viewpoint of our local hidden-variable model. Finally, we mention that this theory could perhaps be relativistically extended and useful for the formulation of quantum mechanics in curved space-times. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  14. improvement of power system quality using vsc-based hvdc

    African Journals Online (AJOL)

    HOD

    Key words: HVDC, Voltage source converter (VSC), Current and Voltage Control Loop; FFT Analysis ... The main requirement in a power transmission system is .... drop over the reactor (. ) ..... Distribution Conference and Exhibition: Asia and.

  15. Development of a coordinated control system for BWR nuclear power plant and HVDC transmission system

    International Nuclear Information System (INIS)

    Ishikawa, M.; Hara, T.; Hirayama, K.; Sekiya, K.

    1986-01-01

    The combined use of dc and ac transmissions or so-called hybrid transmission was under study, employing both dc and ac systems to enable stable transmission of 10,000 MW of electric power generated by the BWR nuclear plant, scheduled to be built about 800 km away from the center of the load. It was thus necessary to develop a hybrid power transmission control system, the hybrid power transmission system consisting of a high voltage dc transmission system (HVDC) and an ultrahigh ac transmission system (UHVAC). It was also necessary to develop a control system for HVDC transmission which protects the BWR nuclear power plant from being influenced by any change in transmission mode that occurs as a result of faults on the UHVAC side when the entire power of the BWR plant is being sent by the HVDC transmission. This paper clarifies the requirements for the HVDC system control during hybrid transmission and also during dc transmission. The control method that satisfies these requirements was studied to develop a control algorithm

  16. Suggested Methods for Preventing Core Saturation Instability in HVDC Transmission Systems

    Energy Technology Data Exchange (ETDEWEB)

    Norheim, Ian

    2002-07-01

    In this thesis a study of the HVDC related phenomenon core saturation instability and methods to prevent this phenomenon is performed. It is reason to believe that this phenomenon caused disconnection of the Skagerrak HVDC link 10 August 1993. Internationally, core saturation instability has been reported at several HVDC schemes and thorough complex studies of the phenomenon has been performed. This thesis gives a detailed description of the phenomenon and suggest some interesting methods to prevent the development of it. Core saturation instability and its consequences can be described in a simplified way as follows: It is now assumed that a fundamental harmonic component is present in the DC side current. Due to the coupling between the AC side and the DC side of the HVDC converter, a subsequent second harmonic positive-sequence current and DC currents will be generated on the AC side. The DC currents will cause saturation in the converter transformers. This will cause the magnetizing current to also have a second harmonic positive-sequence component. If a high second harmonic impedance is seen from the commutation bus, a high positive-sequence second harmonic component will be present in the commutation voltages. This will result in a relatively high fundamental frequency component in the DC side voltage. If the fundamental frequency impedance at the DC side is relatively low the fundamental component in the DC side current may become larger than it originally was. In addition the HVDC control system may contribute to the fundamental frequency component in the DC side voltage, and in this way cause a system even more sensitive to core saturation instability. The large magnetizing currents that eventually will flow on the AC side cause large zero-sequence currents in the neutral conductors of the AC transmission lines connected to the HVDC link. This may result in disconnection of the lines. Alternatively, the harmonics in the large magnetizing currents may cause

  17. Fault Ride-Through Capability Enhancement of VSC HVDC connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Cha, Seung-Tae

    2015-01-01

    This paper presents a feed forward direct current (DC) voltage control based fault ride-through (FRT) scheme for voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs) in order to achieve active control of the WPP collector network AC voltage magnitude......, and to improve the FRT capability. During steady state operation, an open loop AC voltage control is implemented at the WPP side VSC of the HVDC system such that any possible control interactions between the WPP side VSC and the wind turbine VSC are minimized. Whereas during any grid faults, a dynamic AC voltage...... reference is applied based on both the DC voltage error and the AC active-current from the WPP collector system which ensures fast and robust FRT of the VSC HVDC connected offshore WPPs. Under unbalanced fault conditions in the host power system, the resulting oscillatory DC voltage is directly used...

  18. Cluster Control of Offshore Wind Power Plants Connected to a Common HVDC Station

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sakamuri, Jayachandra N.; Rapp, C. Andrea

    2016-01-01

    of offshore AC grid voltage control and onshore ancillary services provision, i.e. POD by the active power modulation of the cluster. The two cases are simulated using DIgSILENT PowerFactory, where the IEC 61400-27-1 wind turbine and WPP control models and a generic offshore layout with cluster of three WPPs......In this paper a coordinated control for cluster of offshore WPPs connected to the same HVDC connection is being implemented and analyzed. The study is targeting two cases as; coordination of reactive power flow between HVDC converter and the WPP cluster while providing offshore AC grid voltage...... control, and coordinated closed loop control between the HVDC and the WPPs while the cluster is providing Power Oscillation Damping ( POD) via active power modulation. It is shown that the coordinated cluster control helps to improve the steady-state and dynamic response of the offshore AC grid in case...

  19. A Droop Line Tracking Control for Multi-terminal VSC-HVDC Transmission System

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2018-01-01

    Generally, a voltage-sourced converter (VSC) within a multi-terminal HVDC (MTDC) system can be operated either in constant DC voltage, constant flow (AC active power or DC current) or DC voltage droop control. These control modes can be easily represented as the droop characteristic line with dif......Generally, a voltage-sourced converter (VSC) within a multi-terminal HVDC (MTDC) system can be operated either in constant DC voltage, constant flow (AC active power or DC current) or DC voltage droop control. These control modes can be easily represented as the droop characteristic line...

  20. improvement of power system quality using vsc-based hvdc

    African Journals Online (AJOL)

    HOD

    transmission is its ability to independently control the reactive and real power flow ... Key words: HVDC, Voltage source converter (VSC), Current and Voltage Control Loop; FFT Analysis ..... waveform and FFT wave spectrum, the DC side filters.

  1. MRI versus CT in the diagnosis of Nelson's syndrome

    International Nuclear Information System (INIS)

    Kasperlik-Zaluska, A.; Walecki, J.; Brzezinski, J.; Jeske, W.; Migdalska, B.; Bonicki, W.; Brzezinska, A.; Makowska, A.

    1997-01-01

    The purpose of the study was to evaluate the utility of MRI and CT in the diagnosis of Nelson's syndrome, i. e. pituitary tumours in patients bilaterally adrenalectomized for Cushing's disease. Thirteen patients, followed up for 5-29 years after adrenalectomy, were studied. In 6 of them CT and MRI revealed no changes in the pituitary gland. In the remaining 7 patients only three CT scans were suggestive of a pituitary adenoma. MRI studies with administration of gadodiamide confirmed the CT diagnosis of Nelson's tumour in 3 patients and disclosed microadenomas in a further 4 patients. Neurosurgical treatment in 4 patients confirmed the MRI findings. Additionally CT and MRI examinations were performed in 5 patients suspected of a recurrent Nelson's tumour 3-11 years after neurosurgery. MRI visualized recurrent adenomas in 3 patients that were not well seen by CT scans. In our experience MRI was more effective than CT in the diagnosis of Nelson's syndrome. (orig.). With 3 figs., 1 tab

  2. The need for a common standard for voltage levels of HVDC VSC technology

    International Nuclear Information System (INIS)

    Müller, H.K.; Torbaghan, S. Shariat; Gibescu, M.; Roggenkamp, M.M.; Meijden, M.A.M.M. van der

    2013-01-01

    The expansion of offshore wind energy as well as the increase in electricity trade between the North Sea countries leads to a growing need for additional transmission capacity. Due to the predominantly remote locations of offshore wind farms, the majority of future connections will be high-voltage direct current (HVDC) connections. In order to make the construction of offshore infrastructure more efficient, the North Sea states are currently discussing the development of a common offshore grid. Although this development still stands at the very beginning, we argue in this paper that some crucial elements should be standardized from the outset; the most important one being a common voltage level. Without such standardization, the development of a European offshore grid may be suboptimal, not cost-efficient and might even be prevented from coming into existence. We examine the technical and legal issues associated with introducing a common voltage level for the use of HVDC VSC technology, and discuss the optimal standard as well as the way in which this common standard can best be achieved. - Highlights: • We highlight the need for a common standard for HVDC VSC technology. • We outline that a standardized voltage level at ± 500 kV should be the initial focus. • We discuss the developments regarding standardization of HVDC VSC technology. • We conclude that current developments are not sufficient

  3. Present trends in HVDC converter station design

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, Lennart; Asplund, Gunnar; Bjorklund, Hans; Flisberg, Gunnar [ABB Power Systems AB, Ludvika (Sweden)

    1994-12-31

    HVDC converter station technology has developed rapidly to satisfy increasing requirements during past 10 - 15 years, but there has not been any dramatic changes since thyristor valves were introduced in the mid 70s. This paper describes some recent and expected future developments, that will substantiality change and simplify future converter stations. (author) 4 refs., 7 figs.

  4. Nelson-Farrar quarterly costimating

    International Nuclear Information System (INIS)

    Farrar, G.

    1993-01-01

    This paper reports that continuing a trend starting in 1983, the Nelson-Farrar refinery construction index rose slowly from 1211.6 in January 1990, to 1265.8 in December 1991. The labor component of the index rose at a more rapid rate than did the material component. The labor index rose from 1469.5 to 1558.1 over the 2-year period, while the material index rose only 2.3 points, from 824.9 to 827.2. The miscellaneous equipment index rose 52.1 points in the 2-year comparison. The category includes pumps and compressors, electrical equipment, heat exchangers, instruments, and engines. They are thus manufactured items, and their costs are a measure of manufacturing efficiency. The Nelson-Farrar refinery operations index dropped 5.4 points, from 395.1 to 389.7 in the 1990-1991 period. The process unit index also showed a decrease over this period, dropping from 469.3 to 405.2

  5. Discrete-Time Nonlinear Control of VSC-HVDC System

    Directory of Open Access Journals (Sweden)

    TianTian Qian

    2015-01-01

    Full Text Available Because VSC-HVDC is a kind of strong nonlinear, coupling, and multi-input multioutput (MIMO system, its control problem is always attracting much attention from scholars. And a lot of papers have done research on its control strategy in the continuous-time domain. But the control system is implemented through the computer discrete sampling in practical engineering. It is necessary to study the mathematical model and control algorithm in the discrete-time domain. The discrete mathematical model based on output feedback linearization and discrete sliding mode control algorithm is proposed in this paper. And to ensure the effectiveness of the control system in the quasi sliding mode state, the fast output sampling method is used in the output feedback. The results from simulation experiment in MATLAB/SIMULINK prove that the proposed discrete control algorithm can make the VSC-HVDC system have good static, dynamic, and robust characteristics in discrete-time domain.

  6. Integration of wind power in Germany's transmission grid by using HVDC links

    Energy Technology Data Exchange (ETDEWEB)

    Wasserrab, Andreas; Fleckenstein, Marco; Balzer, Gerd [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power and Energy

    2012-07-01

    This paper deals with the challenges for the integration of wind power in Germany's transmission grid. Several options for the expansion of transmission grids are discussed. The consideration focuses on HVDC technologies, which are used for further analyses. The basis of the analysis is the transmission grid of a German transmission system operator, which is implemented in a simulation tool. The model consists of the 110-kV-, 220-kV- and the 380-kV-system. In different scenarios the integration of wind power is analysed by applying HVDC links to connect the northern part of the grid with the load centres in the South. The results of load flow calculations are discussed focusing on transmission line loading and voltage stability. The paper concludes with future prospects of HVDC applications in Germany. (orig.)

  7. Application of VSC-HVDC with Shunt Connected SMES for Compensation of Power Fluctuation

    Science.gov (United States)

    Linn, Zarchi; Kakigano, Hiroaki; Miura, Yushi; Ise, Toshifumi

    This paper describes the application of VSC-HVDC (High Voltage DC Transmission using Voltage Source Converter) with shunt connected SMES (Superconducting Magnetic Energy Storage) for compensation of power fluctuation caused by fluctuating power source such as photovoltaics and wind turbines. The objectives of this proposed system is to smooth out fluctuating power in one terminal side of HVDC in order to avoid causing power system instability and frequency deviation by absorbing or providing power according to the system requirement while another terminal side power is fluctuated. The shunt connected SMES charges and discharges the energy to and from the dc side and it compensates required power of fluctuation to obtain constant power flow in one terminal side of VSC-HVDC system. This system configuration has ability for power system stabilization in the case of power fluctuation from natural energy source. PSCAD/EMTDC simulation is used to evaluate the performance of applied system configuration and control method.

  8. Modeling and power system stability of VSC-HVDC systems for grid-connection of large offshore windfarms

    Energy Technology Data Exchange (ETDEWEB)

    Xue Yijing [Vestas China, Beijing (China); Akhmatov, Vladislav [Technical Univ. of Denmark, Lyngby (Denmark). Centre for Electric Technology

    2009-07-01

    Utilization of Voltage Source Converter (VSC) - High Voltage Direct Current (HVDC) systems for grid-connection of large offshore windfarms becomes relevant as installed power capacities as well as distances to the connection points of on-land transmission systems increase. At the same time, the grid code requirements of the Transmission System Operators (TSO), including ancillary system services and Low-Voltage Fault-Ride-Through (LVFRT) capability of large offshore windfarms, become more demanding. This paper presents a general-level model of and a LVFRT solution for a VSC-HVDC system for grid-connection of large offshore windfarms. The VSC-HVDC model is implemented using a general approach of independent control of active and reactive power in normal operations. The on-land VSC inverter, i.e. a grid-side inverter, provides voltage support to the transmission system and comprises a LVFRT solution in short-circuit faults. The presented model, LVFRT solution and impact on the system stability are investigated as a case study of a 1,000 MW offshore windfarm grid-connected through a VSC-HVDC system. The investigation is carried out on a model of the west Danish, with some elements of the north German, 400 kV, 220 kV and 150 kV transmission systems stage 2005-2006 using the DIgSILENT PowerFactory simulation program. In the investigation, a thermal power plant just south to the Danish border has been substituted by this 1,000 MW offshore windfarm utilizing the VSC-HVDC system. The investigation has shown that the substitution of a thermal power plant by a VSC-HVDC connected offshore windfarm should not have any negative impact on the short-term stability of the west Danish transmission system. The investigation should be repeated applying updated system model stages and offshore wind power commissioning schedules in the North and Baltic Seas. (orig.)

  9. Challenges for the Nelson-Barr mechanism

    International Nuclear Information System (INIS)

    Dine, Michael; Draper, Patrick

    2015-01-01

    The axion and m u =0 solutions to the strong CP problem have been subject to the most careful scrutiny and critique. Basic theoretical issues include hierarchy and fine-tuning problems, quality and genericity of symmetries, and compatibility with solutions to the electroweak hierarchy problem. We study the similar set of challenges for solutions to strong CP based on spontaneous CP violation and the Nelson-Barr mechanism. Some of our observations have appeared in the literature previously, and others are new; our purpose is to collect and analyze the issues as a whole and provide an assessment of the most plausible settings for the Nelson-Barr solution.

  10. Modelling and Simulation of VSC-HVDC Connection for Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2010-01-01

    Several large offshore wind power plants (WPP) are planned in the seas around Europe. VSC-HVDC is a suitable means of integrating such large and distant offshore WPP which need long submarine cable transmission to the onshore grid. Recent trend is to use large wind turbine generators with full...... scale converters to achieve an optimal operation over a wide speed range. The offshore grid then becomes very much different from the conventional power system grid, in the sense that it is connected to power electronic converters only. A model of the wind power plant with VSC-HVDC connection...

  11. Redundancy Determination of HVDC MMC Modules

    Directory of Open Access Journals (Sweden)

    Chanki Kim

    2015-08-01

    Full Text Available An availability and a reliability prediction has been made for a high-voltage direct-current (HVDC module of VSC (Voltage Source Converter containing DC/DC converter, gate driver, capacitor and insulated gate bipolar transistors (IGBT. This prediction was made using published failure rates for the electronic equipment. The purpose of this prediction is to determinate the additional module redundancy of VSC and the used method is “binomial failure method”.

  12. A Combined Reliability Model of VSC-HVDC Connected Offshore Wind Farms Considering Wind Speed Correlation

    DEFF Research Database (Denmark)

    Guo, Yifei; Gao, Houlei; Wu, Qiuwei

    2017-01-01

    and WTGs outage. The wind speed correlation between different WFs is included in the two-dimensional multistate WF model by using an improved k-means clustering method. Then, the entire system with two WFs and a threeterminal VSC-HVDC system is modeled as a multi-state generation unit. The proposed model...... is applied to the Roy Billinton test system (RBTS) for adequacy studies. Both the probability and frequency indices are calculated. The effectiveness and accuracy of the combined model is validated by comparing results with the sequential Monte Carlo simulation (MCS) method. The effects of the outage of VSC-HVDC...... system and wind speed correlation on the system reliability were analyzed. Sensitivity analyses were conducted to investigate the impact of repair time of the offshore VSC-HVDC system on system reliability....

  13. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Kyu, E-mail: power@changwon.ac.kr [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Kim, Kwangmin; Park, Minwon [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Lee, Sangjin [Uiduk University, Gyeongju 780-713 (Korea, Republic of)

    2015-11-15

    Highlights: • A 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC transmission system. • The 400 mH class HTS DC reactor was connected to real power network via the HVDC system. • The DC current flowed in HTS DC reactor has several harmonic components and it was analyzed using FFT. - Abstract: High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  14. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    International Nuclear Information System (INIS)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-01-01

    Highlights: • A 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC transmission system. • The 400 mH class HTS DC reactor was connected to real power network via the HVDC system. • The DC current flowed in HTS DC reactor has several harmonic components and it was analyzed using FFT. - Abstract: High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  15. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    power transmission options with HVDC systems are under consideration. In this paper, a comparison between a conventional HVAC transmission system and a HVDC system equipped with modular voltage source converters is provided. The comparison is based on the total energy transmission capability...

  16. On the domain of the Nelson Hamiltonian

    Science.gov (United States)

    Griesemer, M.; Wünsch, A.

    2018-04-01

    The Nelson Hamiltonian is unitarily equivalent to a Hamiltonian defined through a closed, semibounded quadratic form, the unitary transformation being explicitly known and due to Gross. In this paper, we study the mapping properties of the Gross-transform in order to characterize the regularity properties of vectors in the form domain of the Nelson Hamiltonian. Since the operator domain is a subset of the form domain, our results apply to vectors in the domain of the Hamiltonian as well. This work is a continuation of our previous work on the Fröhlich Hamiltonian.

  17. Power Hardware In The Loop Validation of Fault Ride Through of VSC HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Cha, Seung-Tae

    2014-01-01

    This paper presents the power hardware in the loop (PHIL) validation of a feed forward DC voltage control scheme for the fault ride through (FTR) of voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs). In the proposed FRT scheme, the WPP collector...... network AC voltage is actively controlled by considering both the DC voltage error and the AC current from the WPP AC collector system which ensures fast and robust FRT of the VSC HVDC connected offshore WPPs. The PHIL tests were carried out in order to verify the efficacy of the proposed feed forward DC...... voltage control scheme for enhancing the FRT capability of the VSC HVDC connected WPPs. The PHIL test results have demonstrated the proper control coordination between the offshore WPP and the WPP side VSC and the efficient FRT of the VSC HVDC connected WPPs....

  18. Late Quaternary pollen records from the Lower Cobb Valley and adjacent areas, north-west Nelson, New Zealand

    International Nuclear Information System (INIS)

    Shulmeister, J.; McLea, W.L.; Singer, C.; McKay, R.M.; Hosie, C.

    2003-01-01

    Ten pollen records from the Cobb Valley and adjacent areas in North-West Nelson are described. Collectively they provide a vegetation record extending from the Last Glacial Maximum to the present day. During the Last Glacial Maximum the uplands of North-West Nelson were glaciated. By about 17,000 radiocarbon years BP ice had retreated some distance up the Cobb River Valley and a podocarp heath and tussockland vegetation covered non-glaciated areas. By 14,000 radiocarbon years BP, the valley floor and adjacent lower ridges were occupied by montane podocarp forest dominated by Phyllocladus and Halocarpus. Beech forest expanded into some sites as early as 13,000 yr BP but the modern beech cover was not established until the Holocene. Forest cover has fluctuated in response to disturbance over the Holocene, but the most significant recent change, which is related to clearing for pastoralism in the last two centuries, has had surprisingly little impact on the pollen records. (author). 40 refs., 11 figs., 1 tab

  19. Asymmetrical Fault Analysis at the Offshore Network of HVDC connected Wind Power Plants

    DEFF Research Database (Denmark)

    Goksu, Omer; Cutululis, Nicolaos Antonio; Sorensen, Poul

    2017-01-01

    Short-circuit faults for HVDC connected Wind Power Plants (WPPs) have been studied mostly for dc link and onshore ac grid faults, while the offshore ac faults, especially asymmetrical faults, have been mostly omitted in the literature. Requirements related to the offshore asymmetrical faults have...... been kept as future development at national levels in the recent ENTSO-E HVDC network code. In this paper offshore ac faults are studied using the classical power system fault analysis methods. It is shown that suppression of negative sequence current flow is not applicable and negative sequence...

  20. Power Flow Analysis of HVAC and HVDC Transmission Systems for Offshore WindParks

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Castro, Rui

    2009-01-01

    As the onshore wind resource is running shorter, wind power promoters are paying attention to the offshore resources. As in most cases there is no load offshore, wind power must be transmitted to the main land. To do so, two options are available: HVAC and HVDC transmission systems. In this paper...... that HVAC solution is limited by the distance to shore and by the wind transmitted power. HVDC options do not show these limitations, but are more expensive and more delicate to deal with, because there is a lack of operational experience, so far....

  1. Surface Layer Fluorination-Modulated Space Charge Behaviors in HVDC Cable Accessory

    Directory of Open Access Journals (Sweden)

    Jin Li

    2018-05-01

    Full Text Available Space charges tend to accumulate on the surface and at the interface of ethylene–propylene–diene terpolymer (EPDM, serving as high voltage direct current (HVDC cable accessory insulation, which likely induces electrical field distortion and dielectric breakdown. Direct fluorination is an effective method to modify the surface characteristics of the EPDM without altering the bulk properties too much. In this paper, the surface morphology, hydrophobic properties, relative permittivity, and DC conductivity of the EPDM before and after fluorination treatment were tested. Furthermore, the surface and interface charge behaviors in the HVDC cable accessory were investigated by the pulsed electroacoustic (PEA method, and explained from the point of view of trap distribution. The results show that fluorination helps the EPDM polymer obtain lower surface energy and relative permittivity, which is beneficial to the interface match in composite insulation systems. The lowest degree of space charge accumulation occurs in EPDM with 30 min of fluorination. After analyzing the results of the 3D potentials and the density of states (DOS behaviors in EPDM before and after fluorination, it can be found that fluorination treatment introduces shallower electron traps, and the special electrostatic potential after fluorination can significantly suppress the space charge accumulation at the interface in the HVDC cable accessory.

  2. Field tests of Sub-Synchronous Oscillation damping and frequency controllers of the Rihand-Delhi HVDC bipole

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Mata [ABB, New Delhi (India); Rao, L V; Chakravorty, S; Moni, R S; Dass, R [National Thermal Power Corporation Ltd., New Delhi (India); Mishra, R B; Tripathi, D B [Powergrid (India); Bjorklund, Hans; Duchen, Hugo; Westling, Soren [ABB Power Systems, Ludvika (Sweden)

    1994-12-31

    The Rihand-Delhi Hvdc transmission system comprises of two poles in bipolar mode, each of 750 MW nominal capacity. The length of the transmission line is 814 km and the main objective of the link is the transmission of bulk power from the Singrauli/Rihand thermal generating complex to the major load centers near the National Capital region. As in all major Hvdc schemes, the Rihand-Delhi Hvdc project has also been provided with a SSO damping controller which was extensively tested in the simulator prior to installation. This paper describes some of the important field tests conducted to ascertain actual performance and compares the same with corresponding simulator cases. Also covered is the performance of the frequency controller. (author) 3 refs., 9 figs.

  3. Marilyn Nelson: Poetic Justice

    Science.gov (United States)

    Pierpont, Katherine

    2006-01-01

    This article features some of the books written by Marilyn Nelson. Here, the author discusses how she has written a children's book of poetry about lynching, entitled "A Wreath for Emmitt Till." The author discusses how her books for children honor and memorialize history-changing African Americans. Among other things, the author discusses some of…

  4. New long-distance transmissions in Russia may use hvdc

    Energy Technology Data Exchange (ETDEWEB)

    1940-09-01

    Hvdc is considered for Kuibyshev-Moscow and other future Russian long-distance transmissions as a means to obtain higher transmission capacity and lower losses. A total saving of 46% is calculated as compared with ac transmission. An experimental transmission line will be built shortly.

  5. Optimal Power Transmission of Offshore Wind Power Using a VSC-HVdc Interconnection

    Directory of Open Access Journals (Sweden)

    Miguel E. Montilla-DJesus

    2017-07-01

    Full Text Available High-voltage dc transmission based on voltage-source converter (VSC-HVdc is quickly increasing its power rating, and it can be the most appropriate link for the connection of offshore wind farms (OWFs to the grid in many locations. This paper presents a steady-state operation model to calculate the optimal power transmission of an OWF connected to the grid through a VSC-HVdc link. The wind turbines are based on doubly fed induction generators (DFIGs, and a detailed model of the internal OWF grid is considered in the model. The objective of the optimization problem is to maximize the active power output of the OWF, i.e., the reduction of losses, by considering the optimal reactive power allocation while taking into account the restrictions imposed by the available wind power, the reactive power capability of the DFIG, the DC link model, and the operating conditions. Realistic simulations are performed to evaluate the proposed model and to execute optimal operation analyses. The results show the effectiveness of the proposed method and demonstrate the advantages of using the reactive control performed by DFIG to achieve the optimal operation of the VSC-HVdc.

  6. Review of the development of multi-terminal HVDC and DC power grid

    Science.gov (United States)

    Chen, Y. X.

    2017-11-01

    Traditional power equipment, power-grid structures, and operation technology are becoming increasingly powerless with the large-scale renewable energy access to the grid. Thus, we must adopt new technologies, new equipment, and new grid structure to satisfy future requirements in energy patterns. Accordingly, the multiterminal direct current (MTDC) transmission system is receiving increasing attention. This paper starts with a brief description of current developments in MTDC worldwide. The MTDC project, which has been placed into practical operation, is introduced by the Italian-Corsica-Sardinian three-terminal high-voltage DC (HVDC) project. We then describe the basic characteristics and regulations of multiterminal DC transmission. The current mainstream of several control methods are described. In the third chapter, the key to the development of MTDC system or hardware and software technology that restricts the development of multiterminal DC transmission is discussed. This chapter focuses on the comparison of double-ended HVDC and multiterminal HVDC in most aspects and subsequently elaborates the key and difficult point of MTDC development. Finally, this paper summarizes the prospect of a DC power grid. In a few decades, China can build a strong cross-strait AC-DC hybrid power grid.

  7. Cooperative control of VSC-HVDC connected offshore wind farm with Low-Voltage Ride-Through capability

    DEFF Research Database (Denmark)

    Liu, Yan; Wang, Xiongfei; Chen, Zhe

    2012-01-01

    The Low-Voltage Ride-Through (LVRT) has become an important grid requirement for offshore wind farms connecting with Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) links. In this paper, a cooperative control strategy with LVRT ability is proposed for a VSC-HVDC connected...... variable speed Squirrel-Cage Induction Generator (SCIG) wind farm. The approach employs a DC-link voltage versus offshore AC-bus frequency droop control on the offshore converter of VSC-HVDC link. Thus, the back-to-back converters of SCIG wind turbines can adjust the generated active power based on the AC......-bus frequency deviations, so that a fast power reduction on the wind farm side can be achieved. The EMTDC/PSCAD simulations are performed on a 300 MW offshore variable speed SCIG wind farm. Simulation results confirm the effectiveness of the proposed control method....

  8. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    Science.gov (United States)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-11-01

    High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  9. A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

    Directory of Open Access Journals (Sweden)

    Liu Longchen

    2016-01-01

    Full Text Available The converter valve is the core equipment in the HVDC power transmission system, a+-nd its performance has a direct effect on the reliability, stability and efficiency of the whole power system. As the basic unit of HVDC converter valve, the thyristor level needs to be test routinely in order to grasp the state of the converter valve equipment. Therefore, it is urgent to develop a novel synthetic test system for the thyristor level with thyristor control unit (TCU. However, currently there is no specific test scheme for the thyristor level of HVDC converter valve. In this paper, the synthetic test principle, content and methods for the thyristor level with TCU are presented based on the analysis of the thyristor reverse recovery characteristic and the IEC technology standard. And a transient high-voltage pulse is applied to the thyristor level during its reverse recovery period in order to test the characteristics of thyristor level. Then, the synthetic test system for the thyristor level is applied to the converter valve test of ±800 kV HVDC power transmission project, and the practical test result verifies the reasonability and validity of the proposed synthetic test system.

  10. An Examination of AC/HVDC Power Circuits for Interconnecting Bulk Wind Generation with the Electric Grid

    Directory of Open Access Journals (Sweden)

    Daniel Ludois

    2010-06-01

    Full Text Available The application of high voltage dc (HVDC transmission for integrating large scale and/or off-shore wind generation systems with the electric grid is attractive in comparison to extra high voltage (EHV ac transmission due to a variety of reasons. While the technology of classical current sourced converters (CSC using thyristors is well established for realization of large HVDC systems, the technology of voltage sourced converters (VSC is emerging to be an alternative approach, particularly suitable for multi-terminal interconnections. More recently, a more modular scheme that may be termed ‘bridge of bridge’ converters (BoBC has been introduced to realize HVDC systems. While all these three approaches are functionally capable of realizing HVDC systems, the converter power circuit design trade-offs between these alternatives are not readily apparent. This paper presents an examination of these topologies from the point of view of power semiconductor requirements, reactive component requirements, operating losses, fault tolerance, multi-terminal operation, modularity, complexity, etc. Detailed analytical models will be used along with a benchmark application to develop a comparative evaluation of the alternatives that maybe used by wind energy/bulk transmission developers for performing engineering trade-off studies.

  11. Offshore Wind Farms and HVDC Grids Modeling as a Feedback Control System for Stability Analysis

    OpenAIRE

    Bidadfar, Ali; Saborío-Romano, Oscar; Altin, Müfit; Göksu, Ömer; Cutululis, Nicolaos Antonio; Sørensen, Poul Ejnar

    2017-01-01

    The low impedance characteristics of DC transmission lines cause the voltage source converter (VSC) in HVDC networks to become electrically closer together and increase the risk of severe interactions between the converters. Such interactions, in turn, intensify the implementation of the grid control schemes and may lead the entire system to instability. Assessing the stability and adopting complex coordinated control schemes in an HVDC grid and wind farm turbines are challenging and require ...

  12. Performance Analysis of a Voltage Source Converter (VSC based HVDC Transmission System under Faulted Conditions

    Directory of Open Access Journals (Sweden)

    Amiri RABIE

    2009-12-01

    Full Text Available Voltage Source Converter (VSC based HVDC transmission technology hasbeen selected as the basis for several recent projects due to its controllability,compact modular design, ease of system interface, and low environmentalimpact. This paper investigates the dynamic performance of a 200MW,±100kV VSC-HVDC transmission system under some faulted conditionsusing MATLAB/Simulink. Simulation results confirm the satisfactoryperformance of the proposed system under active and reactive powervariations and fault conditions.

  13. Research on Robust Control Strategies for VSC-HVDC

    Science.gov (United States)

    Zhu, Kaicheng; Bao, Hai

    2018-01-01

    In the control system of VSC-HVDC, the phase locked loop provides phase signals to voltage vector control and trigger pulses to generate the required reference phase. The PLL is a typical second-order system. When the system is in unstable state, it will oscillate, make the trigger angle shift, produce harmonic, and make active power and reactive power coupled. Thus, considering the external disturbances introduced by the PLL in VSC-HVDC control system, the parameter perturbations of the controller and the model uncertainties, a H∞ robust controller of mixed sensitivity optimization problem is designed by using the Hinf function provided by the robust control toolbox. Then, compare it with the proportional integral controller through the MATLAB simulation experiment. By contrast, when the H∞ robust controller is added, active and reactive power of the converter station can track the change of reference values more accurately and quickly, and reduce overshoot. When the step change of active and reactive power occurs, mutual influence is reduced and better independent regulation is achieved.

  14. Davidson's generalization of the Fenyes-Nelson stochastic model of quantum mechanics

    International Nuclear Information System (INIS)

    Shucker, D.S.

    1980-01-01

    Davidson's generalization of the Fenyes-Nelson stochastic model of quantum mechanics is discussed. It is shown that this author's previous results concerning the Fenyes-Nelson process extend to the more general theory of Davidson. (orig.)

  15. Review of fault diagnosis and fault-tolerant control for modular multilevel converter of HVDC

    DEFF Research Database (Denmark)

    Liu, Hui; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    This review focuses on faults in Modular Multilevel Converter (MMC) for use in high voltage direct current (HVDC) systems by analyzing the vulnerable spots and failure mechanism from device to system and illustrating the control & protection methods under failure condition. At the beginning......, several typical topologies of MMC-HVDC systems are presented. Then fault types such as capacitor voltage unbalance, unbalance between upper and lower arm voltage are analyzed and the corresponding fault detection and diagnosis approaches are explained. In addition, more attention is dedicated to control...

  16. Disturbance Attenuation of DC Voltage Droop Control Structures in a Multi-Terminal HVDC Grid

    DEFF Research Database (Denmark)

    Thams, Florian; Chatzivasileiadis, Spyros; Prieto-Araujo, Eduardo

    2017-01-01

    DC voltage droop control is seen as the preferred control structure for primary voltage control of future multiterminal HVDC systems. Different droop control structures have been proposed in literature which can be classified in eight categories. This paper contributes to an analysis of the distu......DC voltage droop control is seen as the preferred control structure for primary voltage control of future multiterminal HVDC systems. Different droop control structures have been proposed in literature which can be classified in eight categories. This paper contributes to an analysis...

  17. HVDC Solution for Offshore Wind Park Comprising Turbines Equipped with Full-Range Converters

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    a voltage drop is created at the collection grid, the wind turbines go into fault-ride-through mode. The power output from each of the wind turbines is thus reduced to balance the system power. The detailed explanation of the strategy is presented in the paper. Matlab simulation model was prepared and some...... of a HVDC transmission system. The power system under study includes an offshore wind farm comprising turbines equipped with full range converters. The collection network is a local AC grid. Power transmission is done through HVDC system. The grid side VSC (voltage source converter) controls the DC voltage...

  18. Transients in VSC-HVDC connected offshore wind power plant

    DEFF Research Database (Denmark)

    El-Khatib, Walid Ziad; Schwartzberg, D.; Arana Aristi, I.

    2015-01-01

    The focus of this paper is transient phenomena in VSC-HVDC connected offshore wind power plants (WPPs). With the help of a case study modelled in PSCAD simulation software, energisation events are analysed in the time domain. A comparison with more well-known results obtained at energisation of AC...

  19. Frequency Regulation Strategies in Grid Integrated Offshore Wind Turbines via VSC-HVDC Technology: A Review

    Directory of Open Access Journals (Sweden)

    Jafar Jallad

    2017-08-01

    Full Text Available The inclusion of wind energy in a power system network is currently seeing a significant increase. However, this inclusion has resulted in degradation of the inertia response, which in turn seriously affects the stability of the power system’s frequency. This problem can be solved by using an active power reserve to stabilize the frequency within an allowable limit in the event of a sudden load increment or the loss of generators. Active power reserves can be utilized via three approaches: (1 de-loading method (pitching or over-speeding by a variable speed wind turbine (VSWT; (2 stored energy in the capacitors of voltage source converter-high voltage direct current (VSC-HVDC transmission; and (3 coordination of frequency regulation between the offshore wind farms and the VSC-HVDC transmission. This paper reviews the solutions that can be used to overcome problems related to the frequency stability of grid- integrated offshore wind turbines. It also details the permanent magnet synchronous generator (PMSG with full-scale back to back (B2B converters, its corresponding control strategies, and a typical VSC-HVDC system with an associated control system. The control methods, both on the levels of a wind turbine and the VSC-HVDC system that participate in a system’s primary frequency control and emulation inertia, are discussed.

  20. Steady-state and transient performance of HVDC link based 3-level ...

    African Journals Online (AJOL)

    Administrateur

    DC (HVDC) transmission systems based on three-level voltage source converters. The study involves ..... voltage drops due to the currents across the impedance .... IEEE/PES Transmission and Distribution Conference &. Exhibition: Asia and ...

  1. Research on the Inductance/Capacitance Switch Model for an LCC-HVDC Converter in an AC/DC Hybrid Grid

    Directory of Open Access Journals (Sweden)

    Yangyang He

    2018-03-01

    Full Text Available In order to improve the simulation speed of the AC/DC hybrid grid, the inductance/capacitance (L/C switch model for line-commutated converter of high-voltage direct current (LCC-HVDC is presented in this study. The time domain modeling method is used to analyze the circuit of L/C switch model for the six-pulse system in LCC-HVDC in a switching period. A parameter setting method of L/C switch model is proposed considering the transient response, the steady state performance, switching losses and simulation error of the switch. The inductance/capacitance (L/C switch model for LCC-HVDC has the advantage of keeping the admittance matrix unchanged regardless of the change of switching state, which improves the simulation efficiency. Finally, the validity of the parameter setting method is verified. Compared with the test results of PSCAD/EMTDC, the accuracy of the proposed LCC-HVDC simulation model is proved. The model is suitable for real-time or offline simulation of AC/DC hybrid grid.

  2. Enhanced Dynamic Voltage Stability Support by VSC-HVDC for Offshore Wind Applications using Trajectory Sensitivity Analysis

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe; Liu, Leo

    2013-01-01

    The integration of large-scale wind power plants changes the structure, configuration and operation of conventional power systems and brings challenges to the security and stability of power systems. Dynamic voltage stability of power systems with high wind penetration is one of the critical issues....... In this paper, VSC-HVDC transmission system is used to integrate a large-scale wind power plant into the onshore power grid. For different voltage support strategies of VSC-HVDC, a trajectory sensitivity analysisbased approach is proposed to find the minimum onshore VSC capacity with which the VSC-HVDC can...... provide enough support for the improvement of system voltage stability after a disturbance. Sensitivities of reactive power output of VSC to its capacity increase are calculated instead of the sensitivities of bus voltage magnitude towards the reactive power injection variation of VSC. Simulation results...

  3. Hybrid HVDC (H2VDC System Using Current and Voltage Source Converters

    Directory of Open Access Journals (Sweden)

    José Rafael Lebre

    2018-05-01

    Full Text Available This paper presents an analysis of a new high voltage DC (HVDC transmission system, which is based on current and voltage source converters (CSC and VSC in the same circuit. This proposed topology is composed of one CSC (rectifier and one or more VSCs (inverters connected through an overhead transmission line in a multiterminal configuration. The main purpose of this Hybrid HVDC (H2VDC, as it was designed, is putting together the best benefits of both types of converters in the same circuit: no commutation failure and system’s black start capability in the VSC side, high power converter capability and low cost at the rectifier side, etc. A monopole of the H2VDC system with one CSC and two VSCs—here, the VSC is the Modular Multilevel Converter (MMC considered with full-bridge submodules—in multiterminal configuration is studied. The study includes theoretical analyses, development of the CSC and VSCs control philosophies and simulations. The H2VDC system’s behavior is analyzed by computational simulations considering steady-state operation and short-circuit conditions at the AC and DC side. The obtained results and conclusions show a promising system for very high-power multiterminal HVDC transmission.

  4. Simulation of the large-scale offshore-wind farms including HVDC-grid connections using the simulation tool VIAvento

    Energy Technology Data Exchange (ETDEWEB)

    Bartelt, R.; Heising, C.; Ni, B. [Avasition GmbH, Dortmund (Germany); Zadeh, M. Koochack; Lebioda, T.J.; Jung, J. [TenneT Offshore GmbH, Bayreuth (Germany)

    2012-07-01

    Within the framework of a research project the stability of the offshore grid especially in terms of sub-harmonic stability for the likely future extension stage of the offshore grids i.e. having parallel connection of two or more HVDC links and for certain operating scenarios e.g. overload scenario will be investigated. For this purpose, a comprehensive scenario-based assessment in time domain is unavoidable. Within this paper, the simulation tool VIAvento is briefly presented which allows for these comprehensive time-domain simulations taking the special characteristics of power-electronic assets into account. The core maxims of VIAvento are presented. Afterwards, the capability of VIAvento is demonstrated with simulation results of two wind farms linked via a HVDC grid connection system (160 converters and two HVDC stations in modular multilevel converter topology). (orig.)

  5. Analyzing Oil Futures with a Dynamic Nelson-Siegel Model

    DEFF Research Database (Denmark)

    Hansen, Niels Strange; Lunde, Asger

    In this paper we are interested in the term structure of futures contracts on oil. The objective is to specify a relatively parsimonious model which explains data well and performs well in a real time out of sample forecasting. The dynamic Nelson-Siegel model is normally used to analyze and forec......In this paper we are interested in the term structure of futures contracts on oil. The objective is to specify a relatively parsimonious model which explains data well and performs well in a real time out of sample forecasting. The dynamic Nelson-Siegel model is normally used to analyze...... and forecast interest rates of different maturities. The structure of oil futures resembles the structure of interest rates and this motivates the use of this model for our purposes. The data set is vast and the dynamic Nelson-Siegel model allows for a significant dimension reduction by introducing three...

  6. Nodule management protocol of the NELSON randomised lung cancer screening trial

    NARCIS (Netherlands)

    Xu, Dong Ming; Gietema, Hester; de Koning, Harry; Vernhout, Rene; Nackaerts, Kristiaan; Prokop, Mathias; Weenink, Carla; Lammers, Jan-Willem; Groen, Harry; Oudkerk, Matthijs; van Klaveren, Rob

    In December 2003, the Dutch-Belgian NELSON trial, a Dutch acronym for "Nederlands-Leuvens Longkanker Screenings ONderzoek", has been launched. Primary objective of the NELSON trial is to investigate whether screening for lung cancer by 16-detector multi-slice CT with 16 mm x 0.75 mm collimation and

  7. Calculation of large ion densities under HVdc transmission lines by the finite difference method

    International Nuclear Information System (INIS)

    Suda, Tomotaka; Sunaga, Yoshitaka

    1995-01-01

    A calculation method for large ion densities (charged aerosols) under HVdc transmission lines was developed considering both the charging mechanism of aerosols by small ions and the drifting process by wind. Large ion densities calculated by this method agreed well with the ones measured under the Shiobara HVdc test line on the lateral profiles at ground level up to about 70m downwind from the line. Measured values decreased more quickly than calculated ones farther downwind from the line. Considering the effect of point discharge from ground cover (earth corona) improved the agreement in the farther downwind region

  8. Frequency Support from OWPPs connected to HVDC via Diode Rectifiers

    DEFF Research Database (Denmark)

    Saborío-Romano, Oscar; Bidadfar, Ali; Göksu, Ömer

    This paper presents a study assessing the actual capability of an offshore wind power plant (offshore WPP, OWPP) to provide frequency support (FS) to an onshore network, when connected through a high-voltage direct-current (HVDC) link having a diode rectifier (DR) offshore terminal and a voltage...

  9. Dynamic modelling of VSC-HVDC for connection of offshore wind farms

    DEFF Research Database (Denmark)

    Rios, Bardo; Garcia-Valle, Rodrigo

    2011-01-01

    A VSC-HVDC (Voltage Source Converter – High Voltage Direct Current) dynamic model with a set of control strategies is developed in DIgSILENT Power-Factory with the objective of analyzing the converter’s operating capability for grid support during grid faults. The investigation is carried out based...... on a 165 MW offshore wind farm with induction generators and a Low Voltage Ride-Through solution of the offshore wind turbines and Static Voltage Compensator units in the point of connection with a grid represented by a reduced four-generator power grid model. VSC-HVDC promises to be a reliable alternative...... solution for interconnection with off-shore wind farms as they become larger, with a higher installed power capacity, increased number of wind turbines, and geographically situated at larger distances from suitable connection points in the transmission grids....

  10. Power system integration of VSC-HVDC connected offshore wind power plants

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Kjær, Philip Carne

    This report presents an overview of challenges and solutions for the integration into the power system of offshore wind power plants (WPPs) connected to onshore grids through a voltage-source converter based high voltage direct current (VSC-HVDC) transmission system. Aspects that are touched upon...... of the network in the vicinity of the HVDC station and (iii) limiting characteristics of WPPs such as inherent control and communication delays, presence of mechanical resonances at the same frequency as POD and active power ramp-rate limitations. Clustering of wind power plants The proof of concept...... introduction to justify the study, describe the state-of-art and formulate the project’s objectives, the report is essentially divided into three parts, as follows. Control principles of offshore AC networks The control of offshore AC networks relies purely on power electronics, especially if Type 4 wind...

  11. Effects of HVDC on power systems small signal angle stability

    Energy Technology Data Exchange (ETDEWEB)

    Custodio, D.T.; Paccini, R.O.; Kopcak, I.; Costa, V.F. da [State University of Campinas (UNICAMP), SP (Brazil). School of Electrical and Computer Engineering. Power Systems Dept.], Emails: totti@dsee.fee.unicamp.br, rodrigo@dsee.fee.unicamp.br, kopcak@dsee.fee.unicamp.br, vivaldo@dsee.fee.unicamp.br

    2009-07-01

    In this paper, a didactic method for parameters tuning of the Power Oscillation Damper (POD) coupled to the HVDC constant current controller is proposed utilizing the MATLAB package with a control system toolbox. First, modal analysis is done from the system state matrix to determine the critical mode and oscillation natural frequency. Input and output linearized matrixes are built to single-input and single-output (SISO) control systems. The phase to be compensated between the active power flow in the parallel AC inter-tie and the current reference signal of the HVDC constant current controller is obtained from the Nyquist theorem. Following, the POD time constants are obtained. Finally, the static gain of the POD is tuned based on the root locus method of the classical control theory. Simulations results prove that the DC power modulation is efficient to damp the AC power oscillations. This method is straightforward because only involves matrix operation. (author)

  12. Overvoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery

    Directory of Open Access Journals (Sweden)

    Huiwen He

    2017-01-01

    Full Text Available The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is low. But if the cables were replaced by the overhead lines, although the construction cost of the project would be greatly reduced, the single-pole ground fault rate would be much higher. This paper analyzed the main overvoltage types in multiple-terminal MMC-HVDC network which transmit electric power by overhead lines. Based on ±500 kV multiple-terminal MMC-HVDC for wind power delivery project, the transient simulation model was built and the overvoltage types mentioned above were studied. The results showed that the most serious overvoltage was on the healthy adjacent line of the faulty line caused by the fault clearing of DC breaker. Then the insulation coordination for overhead lines was conducted according to the overvoltage level. The recommended clearance values were given.

  13. Measurement of surface charges on the dielectric film based on field mills under the HVDC corona wire

    Science.gov (United States)

    Donglai, WANG; Tiebing, LU; Yuan, WANG; Bo, CHEN; Xuebao, LI

    2018-05-01

    The ion flow field on the ground is one of the significant parameters used to evaluate the electromagnetic environment of high voltage direct current (HVDC) power lines. HVDC lines may cross the greenhouses due to the restricted transmission corridors. Under the condition of ion flow field, the dielectric films on the greenhouses will be charged, and the electric fields in the greenhouses may exceed the limit value. Field mills are widely used to measure the ground-level direct current electric fields under the HVDC power lines. In this paper, the charge inversion method is applied to calculate the surface charges on the dielectric film according to the measured ground-level electric fields. The advantages of hiding the field mill probes in the ground are studied. The charge inversion algorithm is optimized in order to decrease the impact of measurement errors. Based on the experimental results, the surface charge distribution on a piece of quadrate dielectric film under a HVDC corona wire is studied. The enhanced effect of dielectric film on ground-level electric field is obviously weakened with the increase of film height. Compared with the total electric field strengths, the normal components of film-free electric fields at the corresponding film-placed positions have a higher effect on surface charge accumulation.

  14. Premium Pricing In Health Insurance By Nelson- Aalen Estimator

    OpenAIRE

    Istikaanah, Najmah

    2011-01-01

    In this paper the using of Nelson Aalen estimators are presented to estimate transition probabilities of multistate model. Based on discrete time Markov, we will get transition matrices?é?á which the elements are transition probabilities from Nelson Aalen estimator. Because of the data that used in the construction of transition matrices are person?óÔé¼Ôäós health histories, then it can be seen as a morbidity value, which can be used to premium pricing.?é?á

  15. A New Coordinated Voltage Control Scheme for Offshore AC Grid of HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain

    2015-01-01

    This paper proposes a coordinated voltage control scheme (CVCS) which enhances the voltage ride through (VRT) capability of an offshore AC grid comprised of a cluster of offshore wind power plants (WPP) connected through AC cables to the offshore voltage source converter based high voltage DC (VSC......-HVDC) converter station. Due to limited short circuit power contribution from power electronic interfaced variable speed wind generators and with the onshore main grid decoupled by the HVDC link, the offshore AC grid becomes more vulnerable to dynamic voltage events. Therefore, a short circuit fault...... in the offshore AC Grid is likely to have significant implications on the voltage of the offshore AC grid, hence on the power flow to the onshore mainland grid. The proposed CVCS integrates individual local reactive power control of wind turbines and of the HVDC converter with the secondary voltage controller...

  16. Interactions Between Indirect DC-Voltage Estimation and Circulating Current Controllers of MMC-Based HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Wickramasinghe, Harith R.; Konstantinou, Georgios; Pou, Josep

    2018-01-01

    Estimation-based indirect dc-voltage control in MMCs interacts with circulating current control methods. This paper proposes an estimation-based indirect dc-voltage control method for MMC-HVDC systems and analyzes its performance compared to alternative estimations. The interactions between......-state and transient performance is demonstrated using a benchmark MMC-HVDC transmission system, implemented in a real-time digital simulator. The results verify the theoretical evaluations and illustrate the operation and performance of the proposed indirect dc-voltage control method....

  17. Advanced hybrid transient stability and EMT simulation for VSC-HVDC systems

    NARCIS (Netherlands)

    Van Der Meer, A.A.; Gibescu, M.; Van Der Meijden, M.A.M.M.; Kling, W.L.; Ferreira, J.A.

    2015-01-01

    This paper deals with advanced hybrid transient stability and electromagnetic-transient (EMT) simulation of combined ac/dc power systems containing large amounts of renewable energy sources interfaced through voltage-source converter-high-voltage direct current (VSC-HVDC). The concerning transient

  18. Computationally Efficient Transient Stability Modeling of multi-terminal VSC-HVDC

    DEFF Research Database (Denmark)

    van der Meer, Arjen A; Rueda-Torres, José; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper studies the inclusion of averaged VSC-based grid interfaces and HVDC networks into stability type simulations, and compares the accuracy and speed of three multi-terminal DC dynamic models: 1) a state-space based model, 2) a multi-rate improved model, and 3) a reduced-order model...

  19. Lifetime Estimation of MMC for Offshore Wind Power HVDC Application

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2014-01-01

    of these could lead to thermo-mechanical fatigues in the components and joints of the power modules and thereby causing reliability challenge. This study focuses on the lifetime evaluation of MMC based on power cycling and thermal cycling considering the mission profiles in the High Voltage Direct Current (HVDC...

  20. Lifetime Estimation of MMC for Offshore Wind Power HVDC Application

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Qin, Zian

    2016-01-01

    of these could lead to thermomechanical fatigues in the components and joints of the power modules and thereby causing reliability challenge. This study focuses on the lifetime evaluation of MMC based on power cycling and thermal cycling considering the mission profiles in the High Voltage Direct Current (HVDC...

  1. Asymptotic Completeness for a Renormalized Nonrelativistic Hamiltonian in Quantum Field Theory: The Nelson Model

    International Nuclear Information System (INIS)

    Ammari, Zied

    2000-01-01

    Scattering theory for the Nelson model is studied. We show Rosen estimates and we prove the existence of a ground state for the Nelson Hamiltonian. Also we prove that it has a locally finite pure point spectrum outside its thresholds. We study the asymptotic fields and the existence of the wave operators. Finally we show asymptotic completeness for the Nelson Hamiltonian

  2. Political apathy amongst students: A case study of Nelson Mandela Metropolitan University

    Directory of Open Access Journals (Sweden)

    Ntsikelelo B. Breakfast

    2017-09-01

    Full Text Available The primary motivation for this research, in which a qualitative method was employed, was to examine political apathy amongst students at Nelson Mandela Metropolitan University. The secondary motivation was to question whether youth political apathy threatens the consolidation of democracy. The researchers arranged four focus groups at Nelson Mandela Metropolitan University. A purposive sampling technique was utilised. All 50 participants in the study were Nelson Mandela Metropolitan University undergraduate and postgraduate black students, with ages ranging from 21 to 35 years. The researchers encouraged participants to have maximum participation in the focus group deliberations. The researchers also made use of elite interviews in the study. The findings of this study suggest that political apathy does exist amongst students at Nelson Mandela Metropolitan University. Most of the participants in the focus groups indicated that young people in post-apartheid South Africa have no interest in politics.

  3. DC Vs AC - War Of Currents For Future Power Systems A HVDC Technology Overview

    Directory of Open Access Journals (Sweden)

    Anil K. Rai

    2015-08-01

    Full Text Available DC vs AC discussion began in 1880s with development of first commercial power transmission in Wall Street New York. Later when AC technology came into notice by efforts of inventor and researcher Sir Nicola Tesla soon the advantages of AC transmission and AC devices overtook the DC technology. It was hoped that DC technology had lost battle of currents. Today with researches going on FACTS devices and bulk power transmission HVDC has again gained a reputation in power sector. Solution of this centuries old debate is to develop HVDC systems that assists HVAC systems for better performance stability and control

  4. DC Grid Control Concept for Expandable Multi-terminal HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2018-01-01

    In areas where there are already several HVDC links in operation or under construction, it is more likely that a DC grid emerges as a gradual process. Although the DC grid control concept has been widely discussed, the implementation in the expandable multi-terminal HVDC (MTDC) transmission systems...... still faces challenges. The existing converter control system needs to be adjusted when a point-to-point (PtP) link is operated into MTDC system, or when an additional converter is interconnected with an existing MTDC system, or even when a new DC grid control strategy is applied. In this paper, a new...... DC grid control concept is proposed that conserves and uses the existing converter control when an existing PtP link is extended into MTDC system or the existing MTDC system is expanded. An interface is proposed to decouple the DC grid secondary with converter control structures. By using...

  5. STS-26 MS Nelson on fixed based (FB) shuttle mission simulator (SMS) middeck

    Science.gov (United States)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) George D. Nelson trains on the middeck of the fixed based (FB) shuttle mission simulator (SMS). Nelson, wearing communications assembly headset, adjusts camera mounting bracket.

  6. Nelson's syndrome in pregnancy

    International Nuclear Information System (INIS)

    Surrey, E.S.; Chang, R.J.

    1985-01-01

    The therapeutic considerations in the management of Nelson's syndrome in a 29 year old primigravida are described. CT scans revealed a 2-cm solid pituitary lesion with suprasellar extension and chiasmatic encroachment. A transsphenoidal hypophysectomy was performed to remove a eosinophilic pituitary adenoma. The patient's symptoms improved following surgery. Fetal growth was followed by ultrasound and a female infant was delivered by cesarean section. Follow-up CT scan 2 weeks after delivery revealed no evidence of tumor recurrence

  7. A generic inertia emulation controller for multi-terminal VSC-HVDC systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Booth, Campbell

    2013-01-01

    A generic Inertia Emulation Controller (INEC) for Multi-Terminal Voltage-source-converter based HVDC (VSC-MTDC) is proposed in this paper. The proposed INEC can be incorporated in any grid-side-voltage-source-converter (GVSC) station, allowing the MTDC terminal to contribute an inertial response...

  8. DFIG-based offshore wind power plant connected to a single VSC-HVDC operated at variable frequency: Energy yield assessment

    International Nuclear Information System (INIS)

    De-Prada-Gil, Mikel; Díaz-González, Francisco; Gomis-Bellmunt, Oriol; Sumper, Andreas

    2015-01-01

    The existence of HVDC (High Voltage Direct Current) transmission systems for remote offshore wind power plants allows devising novel wind plant concepts, which do not need to be synchronized with the main AC grid. This paper proposes an OWPP (offshore wind power plant) design based on variable speed wind turbines driven by DFIGs (doubly fed induction generators) with reduced power electronic converters connected to a single VSC-HVDC converter which operates at variable frequency and voltage within the collection grid. It is aimed to evaluate the influence of the power converter size and wind speed variability within the WPP on energy yield efficiency, as well as to develop a coordinated control between the VSC-HVDC converter and the individual back-to-back reduced power converters of each DFIG-based wind turbine in order to provide control capability for the wind power plant at a reduced cost. To maximise wind power generation by the OWPP, an optimum electrical frequency search algorithm for the VSC-HVDC converter is proposed. Both central wind power plant control level and local wind turbine control level are presented and the performance of the system is validated by means of simulations using MATLAB/Simulink ® . - Highlights: • Influence of converter size and wind speed variability on energy capture efficiency. • Coordinated control between a VSC-HVDC and DFIG WTs with reduced power converters. • Static and dynamic analysis of the performance of the implemented control scheme. • Optimal variable frequency operation to maximize WPP generation at a reduced cost

  9. HVDC Connected Offshore Wind Power Plants: Review and Outlook of Current Research

    DEFF Research Database (Denmark)

    Glasdam, Jakob; Zeni, Lorenzo; Gryning, Mikkel

    2013-01-01

    This paper presents a state-of-the-art review on grid integration of large offshore wind power plants (OWPPs) using high voltage direct voltage (HVDC) for grid connection. The paper describes in detail selected challenges hereto and presents how DONG Energy Wind Power (DEWP) is addressing...... these challenges through three coordinated PhD projects in close collaboration with leading academia within the field. The overall goal of these projects is to acquire in-depth knowledge of relevant operating phenomena in the offshore OWPP grid, rich with power electronics devices (PEDs) such as the HVDC...... and the PED widely used in the wind turbine generators (WTGs). Challenges hereto include PED control system interaction (from a stability point of view), assessment of the quality of vendor supplied control systems and their robustness against e.g. short circuits and load rejection. Furthermore, the outcome...

  10. Study on VSC HVDC Modeling and Control Strategies for Wind Power Integration

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei

    Recently, more and more offshore wind farms have been integrated to the power systems. In the next years, these offshore power plants are going to be rated at higher capacities and located in larger distances from the coast. This results in greater interest in the transmission technologies, which....... Finally, more specific requirements are given for the grid connection of offshore wind farms through HVDC systems. These rules derived from the combination of grid codes for the integration of offshore wind farms and grid codes for the operation of HVDC transmission systems, connecting power plants...... are available for the grid connection of the offshore wind farms. In this report various transmission systems are presented. Precisely, the HVAC systems, which have dominated up until now in the power transfer sector, are briefly analysed, by providing their advantages, as well as the bottlenecks that occur...

  11. DC Fault Analysis and Clearance Solutions of MMC-HVDC Systems

    Directory of Open Access Journals (Sweden)

    Zheng Xu

    2018-04-01

    Full Text Available In this paper, the DC short-circuit fault and corresponding clearance solutions of modular multilevel converter-based high-voltage direct current (MMC-HVDC systems are analyzed in detail. Firstly, the analytical expressions of DC fault currents before and after blocking the MMC are derived based on the operation circuits. Before blocking the MMC, the sub-module (SM capacitor discharge current is the dominant component of the DC fault current. It will reach the blocking threshold value in several milliseconds. After blocking the MMC, the SM capacitor is no longer discharged. Therefore, the fault current from the AC system becomes the dominant component. Meanwhile, three DC fault clearance solutions and the corresponding characteristics are discussed in detail, including tripping AC circuit breaker, adopting the full-bridge MMC and employing the DC circuit breaker. A simulation model of the MMC-HVDC is realized in PSCAD/EMTDC and the results of the proposed analytical expressions are compared with those of the simulation. The results show that the analytical DC fault currents coincide well with the simulation results.

  12. Gamma knife radiosurgery for Cushing's disease and Nelson's syndrome.

    Science.gov (United States)

    Marek, Josef; Ježková, Jana; Hána, Václav; Kršek, Michal; Liščák, Roman; Vladyka, Vilibald; Pecen, Ladislav

    2015-06-01

    This paper presents our 18 years of experience in treating ACTH secreting adenomas (Cushing's disease and Nelson's syndrome) using the Leksell gamma knife (LGK) irradiation. Twenty-six patients with Cushing's disease were followed-up after LGK irradiation for 48-216 months (median 78 months). Seventeen patients had undergone previous surgery, in nine patients LGK irradiation was the primary therapy. Furthermore, 14 patients with Nelson's syndrome were followed-up for 30-204 months (median 144 months). LGK treatment resulted in hormonal normalization in 80.7 % of patients with Cushing's disease. Time to normalization was 6-54 months (median 30 months). The volume of the adenoma decreased in 92.3% (in 30.7% disappeared completely). There was no recurrence of the disease. In all 14 patients with Nelson's syndrome ACTH levels decreased (in two patients fully normalized) their ACTH levels. When checked up 5-10 years after irradiation regrowth of the adenoma was only detected in one patient (9.1%), in 27.3% adenoma volume remained unchanged, in 45.4% adenoma volume decreased and in 18.2% adenoma completely disappeared. Hypopituitarism did not develop in any patient where the critical dose to the pituitary and distal infundibulum was respected. LGK radiation represents an effective and well-tolerated option for the treatment of patients with Cushing's disease after unsuccessful surgery and may be valuable even as a primary treatment in patients who are not suitable for, or refuse, surgery. In the case of Nelson's syndrome it is possible to impede tumorous growth and control the size of the adenoma in almost all patients.

  13. Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line

    Science.gov (United States)

    Liu, Yingyi; Zhou, Lijuan; Liu, Yuanqing; Yuan, Haiwen; Ji, Liang

    2017-11-01

    Audible noise is closely related to corona current on a high voltage direct current (HVDC) transmission line. In this paper, we measured a large amount of audible noise and corona current waveforms simultaneously based on the largest outdoor HVDC corona cage all over the world. By analyzing the experimental data, the related statistical regularities between a corona current spectrum and an audible noise spectrum were obtained. Furthermore, the generation mechanism of audible noise was analyzed theoretically, and the related mathematical expression between the audible noise spectrum and the corona current spectrum, which is suitable for all of these measuring points in the space, has been established based on the electro-acoustic conversion theory. Finally, combined with the obtained mathematical relation, the internal reasons for these statistical regularities appearing in measured corona current and audible noise data were explained. The results of this paper not only present the statistical association regularities between the corona current spectrum and the audible noise spectrum on a HVDC transmission line, but also reveal the inherent reasons of these associated rules.

  14. Observations of emperor geese feeding at Nelson Lagoon, Alaska

    Science.gov (United States)

    Petersen, Margaret R.

    1983-01-01

    Estuaries along the north side of the Alaska Peninsula provide essential habitat for most of the American population of Emperor Goose (Chen canagica) during migration (Petersen and Gill 1982). Most of the population passes through Nelson Lagoon in spring and fall, with over 40,000 birds recorded there (Gill et al 1981). Little is known about the feeding activity of Emperor Geese while they are in estuaries, and the importance of estuaries as staging areas during spring and fall migration is poorly understood. Here I report observations on the feeding activity of emperor Geese at one estuary (Nelson Lagoon).

  15. Power system analysis of Hanlim superconducting HVDC system using real time digital simulator

    Science.gov (United States)

    Won, Y. J.; Kim, J. G.; Kim, A. R.; Kim, G. H.; Park, M.; Yu, I. K.; Sim, K. D.; Cho, J.; Lee, S.; Jeong, K. W.; Watanabe, K.

    2011-11-01

    Jeju island is located approximately 100 km south from the mainland of Korea, and had a peak load of about 553 MW in 2008. The demand increases 7.2% a year over the last 5 years. Since the wind profiles of Jeju island are more favorable than mainland of Korea, many companies have shown interest in the wind power business at the Jeju island. Moreover KEPCO has a plan for renewable energy test too whose power will be delivered by HVDC system. One kilometer length of total 8 km was designed as superconducting DC cable. Rest 7 km will be the conventional overhead line. In this paper, the authors have developed a simulation model of the power network around 8 km HVDC system using real time digital simulator (RTDS).

  16. Modeling and real time simulation of an HVDC inverter feeding a weak AC system based on commutation failure study.

    Science.gov (United States)

    Mankour, Mohamed; Khiat, Mounir; Ghomri, Leila; Chaker, Abdelkader; Bessalah, Mourad

    2018-06-01

    This paper presents modeling and study of 12-pulse HVDC (High Voltage Direct Current) based on real time simulation where the HVDC inverter is connected to a weak AC system. In goal to study the dynamic performance of the HVDC link, two serious kind of disturbance are applied at HVDC converters where the first one is the single phase to ground AC fault and the second one is the DC link to ground fault. The study is based on two different mode of analysis, which the first is to test the performance of the DC control and the second is focalized to study the effect of the protection function on the system behavior. This real time simulation considers the strength of the AC system to witch is connected and his relativity with the capacity of the DC link. The results obtained are validated by means of RT-lab platform using digital Real time simulator Hypersim (OP-5600), the results carried out show the effect of the DC control and the influence of the protection function to reduce the probability of commutation failures and also for helping inverter to take out from commutation failure even while the DC control fails to eliminate them. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Offshore VSC-HVDC Networks : Impact on Transient Stability of AC Transmission Systems

    NARCIS (Netherlands)

    van der Meer, A.A.

    2017-01-01

    The transition towards a sustainable society calls for the massive deployment of renewable energy sources such as large wind parks located far offshore. High-voltage direct current transmission based on voltage sourced converter technology (VSC-HVDC) offers a wide range of technological benefits

  18. Influence of current limitation on voltage stability with voltage sourced converter HVDC

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Jóhannsson, Hjörtur; Hansen, Anca Daniela

    2013-01-01

    A first study of voltage stability with relevant amount of Voltage Sourced Converter based High Voltage Direct Current (VSC-HVDC) transmission is presented, with particular focus on the converters’ behaviour when reaching their rated current. The detrimental effect of entering the current...

  19. Rats avoid exposure to HVdc electric fields: a dose response study.

    Science.gov (United States)

    Creim, J A; Lovely, R H; Weigel, R J; Forsythe, W C; Anderson, L E

    1993-01-01

    Rats, given the choice, avoid exposure to alternating current (ac) 60-Hz electric fields at intensities > or = 75 kV/m. This study investigated the generality of this behavior by studying the response of rats when exposed to high voltage direct current (HVdc) electric fields. Three hundred eighty male Long Evans rats were studied in 9 experiments with 40 rats per experiment and in one experiment with 20 rats to determine 1) if rats avoid exposure to HVdc electric fields of varying field strengths, and 2) if avoidance did occur, what role, if any, the concentration of air ions would have on the avoidance behavior. In all experiments a three-compartment glass shuttlebox was used; either the left or right compartment could be exposed to a combination of HVdc electric fields and air ions while the other compartment remained sham-exposed. The third, center compartment was a transition zone between exposure and sham-exposure. In each experiment, the rats were individually assessed in 1-h sessions where half of the rats (n = 20) had the choice to locomote between the two sides being exposed or sham-exposed, while the other half of the rats (n = 20) were sham-exposed regardless of their location, except in one experiment where there was no sham-exposed group. The exposure levels for the first six experiments were 80, 55, 42.5, 30, -36, and -55 kV/m, respectively. The air ion concentration was constant at 1.4 x 10(6) ions/cc for the four positive exposure levels and -1.4 x 10(6) ions/cc for the two negative exposure levels. Rats having a choice between exposure and non-exposure relative to always sham-exposed control animals significantly reduced the amount of time spent on the exposed side at 80 kV/m (P HVdc exposure level was held constant at either -55 kV/m (for three experiments) or -55 kV/m (for 1 experiment) while the air ion concentration was varied between experiments at 2.5 x 10(5) ions/cc, 1.0 x 10(4) for two of the experiments and was below the measurement limit

  20. Environmental isotopes in New Zealand hydrology ; 4. Oxygen isotope variations in subsurface waters of the Waimea Plains, Nelson

    International Nuclear Information System (INIS)

    Stewart, M.K.; Dicker, M.J.I.; Johnston, M.R.

    1981-01-01

    Oxygen isotope measurements of ground and surface waters of the Waimea Plains, Nelson, have been used to identify sources of water in aquifers beneath the plains. Major rivers flowing onto the plains are from higher-altitude catchments (maximum altitude 2000 m) and have delta O 18 approximately equal to -7.2%, whereas rainfall on the plains and adjacent low-altitude catchment streams have delta O 18 approximately equal to -6.2%. The delta O 18 measurements indicate that the 3 major aquifer units, the ''Lower Confined Aquifers'' and the ''Upper Confined Aquifers'' in the Hope Gravel (Late Pleistocene) and the ''Unconfined Aquifers'' in the Appleby Gravel (Holocene) are recharged from different sources. The ''Lower Confined Aquifers'' probably receive slow recharge in the south near Brightwater. The ''Upper Confined Aquifers'' are recharged, in the south, from the Wairoa River and locally in the north are connected with the unconfined aquifers. The ''Unconfined Aquifers'' are recharged from the Waimea River and, away from the river, from rainfall. Intermixing of water, via multiple screened wells, between the various aquifers is also indicated. (author). 5 refs., 5 figs., 1 tab

  1. An improved droop control method for multi-terminal VSC-HVDC converter stations

    DEFF Research Database (Denmark)

    Wang, Hao; Wang, Yue; Duan, Guozhao

    2017-01-01

    Multi-terminal high voltage direct current transmission based on voltage source converter (VSC-HVDC) grids can connect non-synchronous alternating current (AC) grids to a hybrid alternating current and direct current (AC/DC) power system, which is one of the key technologies in the construction...

  2. Linealización de sistemas VSC-HVDC para el diseño de un controlador PI vectorial

    Directory of Open Access Journals (Sweden)

    Nelson Díaz Aldana

    2014-01-01

    Full Text Available Los sistemas VSC-HVDC son muy utilizados para la transmisión de energía en redes de interconexión eléctrica. Uno de los principales problemas que poseen estos sistemas es la complejidad de su modelo matemático, lo que conlleva grandes dificultades para el diseño de controladores que permitan la regulación de parámetros como la tensión DC de transmisión, así como la potencia activa y reactiva del sistema VSC-HVDC. En este artículo se presenta la linealización de un sistema VSC-HVDC y el posterior diseño de un controlador lineal PI vectorial a partir del modelo linealizado. Adicionalmente, se proponen dos estrategias para la validación de este tipo de controladores, la primera consiste en un único controlador PI para regular los estados del sistema para cada VSC, la segunda consiste en el diseño de controladores PI vectoriales independientes para la regulación de cada estado del VSC.

  3. A novel modular multilevel converter modelling technique based on semi-analytical models for HVDC application

    Directory of Open Access Journals (Sweden)

    Ahmed Zama

    2016-12-01

    Full Text Available Thanks to scalability, performance and efficiency, the Modular Multilevel Converter (MMC, since its invention, becomes an attractive topology in industrial applications such as high voltage direct current (HVDC transmission system. However, modelling challenges related to the high number of switching elements in the MMC are highlighted when such systems are integrated into large simulated networks for stability or protection algorithms testing. In this work, a novel dynamic models for MMC is proposed. The proposed models are intended to simplify modeling challenges related to the high number of switching elements in the MMC. The models can be easily used to simulate the converter for stability analysis or protection algorithms for HVDC grids.

  4. Wide-Area Robust Decentralized Coordinated Control of HVDC Power System Based on Polytopic System Theory

    Directory of Open Access Journals (Sweden)

    Shiyun Xu

    2015-01-01

    Full Text Available The present study proposes a hierarchical wide-area decentralized coordinated control framework for HVDC power system that is robust to multiple operating conditions. The upper level wide-area coordinated controller is designed in the form of dynamic output feedback control that coordinates the lower level HVDC supplementary controller, PSS, and SVC. In order to enhance the robustness of the designed controller under various operating conditions, the polytopic model is introduced such that the closed-loop control system can be operated under strong damping mode in virtue of the stability criterion based on damping ratio. Simulation results demonstrate that the proposed controller design algorithm is capable of enhancing the system damping over four different conditions.

  5. Models and methods for assessing the value of HVDC and MVDC technologies in modern power grids

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Yuri V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elizondo, Marcelo A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); O' Brien, James G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Qiuhua [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kirkham, Harold [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Zhenyu [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chinthavali, Madhu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Suman, Debnath [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mohan, Nihal [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Hess, Warren [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Duebner, David [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Orser, David [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Brown, Hilary [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Osborn, Dale [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Feltes, James [Siemens, Knoxville, TN (United States); Kurthakoti Chandrashekhara, Divya [Siemens, Knoxville, TN (United States); Zhu, Wenchun [Siemens, Knoxville, TN (United States)

    2017-07-31

    This report reflects the results of U.S. Department of Energy’s (DOE) Grid Modernization project 0074 “Models and methods for assessing the value of HVDC [high-voltage direct current] and MTDC [multi-terminal direct current] technologies in modern power grids.” The work was done by the Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) in cooperation with Mid-Continent Independent System Operator (MISO) and Siemens. The main motivation of this study was to show the benefit of using direct current (DC) systems larger than those in existence today as they overlap with the alternating current (AC) systems. Proper use of their flexibility in terms of active/reactive power control and fast response can provide much-needed services to the grid at the same time as moving large blocks of energy to take advantage of cost diversity. Ultimately, the project’s success will enable decision-makers and investors to make well-informed decisions regarding this use of DC systems. This project showed the technical feasibility of HVDC macrogrid for frequency control and congestion relief in addition to bulk power transfers. Industry-established models for commonly used technologies were employed, along with high-fidelity models for recently developed HVDC converter technologies; like the modular multilevel converters (MMCs), a voltage source converters (VSC). Models for General Electric Positive Sequence Load Flow (GE PSLF) and Siemens Power System Simulator (PSS/E), widely used analysis programs, were for the first time adapted to include at the same time both Western Electricity Coordinating Council (WECC) and Eastern Interconnection (EI), the two largest North American interconnections. The high-fidelity models and their control were developed in detail for MMC system and extended to HVDC systems in point-to-point and in three-node multi-terminal configurations. Using a continental-level mixed AC-DC grid model, and using a HVDC macrogrid

  6. Small-Signal Dynamic Analysis of LCC-HVDC with STATCOM at the Inverter Busbar

    Science.gov (United States)

    Liu, Dong; Jiang, Wen; Guo, Chunyi; Rehman, Atiq Ur; Zhao, Chengyong

    2018-01-01

    This paper develops a linearized small-signal dynamic model of a Line-Commutated-Converter based HVDC (LCC-HVDC) system with STATCOM at the inverter busbar, and validates its accuracy by comparing time-domain responses from small-signal model and PSCAD-based simulation results. Considering the potential impact of Phase-Locked-Loop (PLL) parameters on the study system and the close connection of STATCOM and LCC inverter station at AC busbar, this paper investigates the impact of PLL gains and AC voltage control parameters of STATCOM on the system small-signal stability. The studies show that (i) the PLL gain has highly impact on the study system and smaller PLL gains are preferable; (ii) larger values of both the proportional gain and the integral gain of AC voltage controller of STATCOM could result in oscillation/instability of the system.

  7. Control System interaction in the VSC-HVDC Grid Connected Offshore Wind Power Plant

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm; Kocewiak, Łukasz Hubert; Hjerrild, Jesper

    2015-01-01

    the source of the instability has been identified and mitigation methods have been designed and implemented. This procedure is not straightforward and can have a long lead time. The harmonic instability can have severe economic consequences for the OWPP owner due to the large investment. Harmonic stability...... the procedure of the stability study and its application for the HVDC grid connected OWPPs. The purpose of this paper is to investigate the harmonic instability phenomena in HVDC grid connected OWPPs using both frequency and time domain simulations. A good correlation at lower frequencies between the two......Conventional offshore wind power plants (OWPPs) are due to the combination of the extensive sub-marine cabling and possible low available short-circuit power at the point of common connection (PCC) susceptible to the harmonic instability phenomena. The instability is caused by the resonances...

  8. Mercury in Nelson's Sparrow subspecies at breeding sites.

    Directory of Open Access Journals (Sweden)

    Virginia L Winder

    Full Text Available BACKGROUND: Mercury is a persistent, biomagnifying contaminant that can cause negative effects on ecosystems. Marshes are often areas of relatively high mercury methylation and bioaccumulation. Nelson's Sparrows (Ammodramus nelsoni use marsh habitats year-round and have been documented to exhibit tissue mercury concentrations that exceed negative effects thresholds. We sought to further characterize the potential risk of Nelson's Sparrows to mercury exposure by sampling individuals from sites within the range of each of its subspecies. METHODOLOGY/PRINCIPAL FINDINGS: From 2009 to 2011, we captured adult Nelson's Sparrows at sites within the breeding range of each subspecies (A. n. nelsoni: Grand Forks and Upham, North Dakota; A. n. alterus: Moosonee, Ontario; and A. n. subvirgatus: Grand Manan Island, New Brunswick and sampled breast feathers, the first primary feather (P1, and blood for total mercury analysis. Mean blood mercury in nelsoni individuals captured near Grand Forks ranged from 0.84 ± 0.37 to 1.65 ± 1.02 SD ppm among years, between 2.0 and 4.9 times as high as concentrations at the other sites (P<0.01. Breast feather mercury did not vary among sites within a given sampling year (site means ranged from 0.98 ± 0.69 to 2.71 ± 2.93 ppm. Mean P1 mercury in alterus (2.96 ± 1.84 ppm fw was significantly lower than in any other sampled population (5.25 ± 2.24-6.77 ± 3.51 ppm; P ≤ 0.03. CONCLUSIONS/SIGNIFICANCE: Our study further characterized mercury in Nelson's Sparrows near Grand Forks; we documented localized and potentially harmful mercury concentrations, indicating that this area may represent a biological mercury hotspot. This finding warrants further research to determine if wildlife populations of conservation or recreational interest in this area may be experiencing negative effects due to mercury exposure. We present preliminary conclusions about the risk of each sampled population to mercury exposure.

  9. Mercury in Nelson's Sparrow Subspecies at Breeding Sites

    Science.gov (United States)

    Winder, Virginia L.; Emslie, Steven D.

    2012-01-01

    Background Mercury is a persistent, biomagnifying contaminant that can cause negative effects on ecosystems. Marshes are often areas of relatively high mercury methylation and bioaccumulation. Nelson's Sparrows (Ammodramus nelsoni) use marsh habitats year-round and have been documented to exhibit tissue mercury concentrations that exceed negative effects thresholds. We sought to further characterize the potential risk of Nelson's Sparrows to mercury exposure by sampling individuals from sites within the range of each of its subspecies. Methodology/Principal Findings From 2009 to 2011, we captured adult Nelson's Sparrows at sites within the breeding range of each subspecies (A. n. nelsoni: Grand Forks and Upham, North Dakota; A. n. alterus: Moosonee, Ontario; and A. n. subvirgatus: Grand Manan Island, New Brunswick) and sampled breast feathers, the first primary feather (P1), and blood for total mercury analysis. Mean blood mercury in nelsoni individuals captured near Grand Forks ranged from 0.84±0.37 to 1.65±1.02 SD ppm among years, between 2.0 and 4.9 times as high as concentrations at the other sites (Pmercury did not vary among sites within a given sampling year (site means ranged from 0.98±0.69 to 2.71±2.93 ppm). Mean P1 mercury in alterus (2.96±1.84 ppm fw) was significantly lower than in any other sampled population (5.25±2.24–6.77±3.51 ppm; P≤0.03). Conclusions/Significance Our study further characterized mercury in Nelson's Sparrows near Grand Forks; we documented localized and potentially harmful mercury concentrations, indicating that this area may represent a biological mercury hotspot. This finding warrants further research to determine if wildlife populations of conservation or recreational interest in this area may be experiencing negative effects due to mercury exposure. We present preliminary conclusions about the risk of each sampled population to mercury exposure. PMID:22384194

  10. Tailored sPP/Silica Nanocomposite for Ecofriendly Insulation of Extruded HVDC Cable

    Directory of Open Access Journals (Sweden)

    Bin Dang

    2015-01-01

    Full Text Available Cross-linked polyethylene (XLPE is a thermosetting material that cannot be recycled at the end of its lifetime. This study investigated the potential of syndiotactic polypropylene (sPP/silica as an ecofriendly extruded insulation system for HVDC cables. We investigated the morphology, Fourier transform infrared, and thermal, thermomechanical, and electrical behaviors of sPP modified with 0.5–3% nanosilica. We found that the silica/sPP nanocomposite without cross-linking offered a suitable mechanical modulus at room temperature and sufficient intensity at high temperatures, and adding nanosilica modified by a silane coupling agent to the sPP resulted in significant DC resistivity and space charge improvement. The optimal nanosilica content in the sPP was determined by balancing the mechanical and thermomechanical characteristics and the DC resistivity. The sPP/silica nanocomposite reported here shows great potential as a candidate insulation material for future ecofriendly extruded HVDC cables.

  11. Grantee Spotlight: Bill Nelson, M.D., Ph.D.

    Science.gov (United States)

    Dr. William (Bill) Nelson is playing an integral role in advancing our understanding of cancer health disparities and helping to foster the interests of young students from underrepresented backgrounds in cancer/cancer health disparities research.

  12. The Detection of Subsynchronous Oscillation in HVDC Based on the Stochastic Subspace Identification Method

    Directory of Open Access Journals (Sweden)

    Chen Shi

    2014-01-01

    Full Text Available Subsynchronous oscillation (SSO usually caused by series compensation, power system stabilizer (PSS, high voltage direct current transmission (HVDC and other power electronic equipment, which will affect the safe operation of generator shafting even the system. It is very important to identify the modal parameters of SSO to take effective control strategies as well. Since the identification accuracy of traditional methods are not high enough, the stochastic subspace identification (SSI method is proposed to improve the identification accuracy of subsynchronous oscillation modal. The stochastic subspace identification method was compared with the other two methods on subsynchronous oscillation IEEE benchmark model and Xiang-Shang HVDC system model, the simulation results show that the stochastic subspace identification method has the advantages of high identification precision, high operation efficiency and strong ability of anti-noise.

  13. Connection of OWPPs to HVDC networks using VSCs and Diode Rectifiers: an Overview

    DEFF Research Database (Denmark)

    Saborío-Romano, Oscar; Bidadfar, Ali; Göksu, Ömer

    This paper provides an overview of two technologies for connecting offshore wind power plants (offshore WPPs, OWPPs) to high-voltage direct current (HVDC) networks: voltage source converters (VSCs) and diode rectifiers (DRs). Current grid code requirements for the connection of such power plants...

  14. HVDC transmission power conversion applications in power systems

    CERN Document Server

    Kim, Chan-Ki; Jang, Gil-Soo; Lim, Seong-Joo; Lee, Seok-Jin

    2009-01-01

    HVDC is a critical solution to several major problems encountered when trying to maintain systemic links and quality in large-scale renewable energy environments. HDVC can resolve a number of issues, including voltage stability of AC power networks, reducing fault current, and optimal management of electric power, ensuring the technology will play an increasingly important role in the electric power industry. To address the pressing need for an up-to-date and comprehensive treatment of the subject, Kim, Sood, Jang, Lim and Lee have collaborated to produce this key text and reference.  Combin

  15. Nelson Werneck Sodré e o "marxismo ocidental"

    Directory of Open Access Journals (Sweden)

    Wilson do Nascimento Barbosa

    1999-12-01

    Full Text Available This articles discusses Nelson Pereira dos Santos' movie Arid lifes, made after homonym Graciliano Ramos' book. Werneck Sodré's methological questions are evoked from book and movie subjects as rural poverty and dayly violence.

  16. Philosophical Remarks on Nelson Mandela's Education Legacy

    Science.gov (United States)

    Waghid, Yusef

    2014-01-01

    In this article, I reflect on Nelson Mandela's (Madiba, the clan name of Mandela) education legacy. I argue that Madiba's education legacy is constituted by three interrelated aspects: firstly, an education for non-violence guided by deliberation, compassion and reconciliation; secondly, education as responsibility towards the Other; and thirdly,…

  17. Variable Frequency Operations of an Offshore Wind Power Plant with HVDC-VSC: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, V.; Singh, M.; Muljadi, E.

    2011-12-01

    In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated. Based on DOE study, wind power generation may reach 330 GW by 2030 at the level of penetration of 20% of the total energy production. From this amount of wind power, 54 GW of wind power will be generated at offshore wind power plants. The deployment of offshore wind power plants requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cable, there is a need to use High-Voltage Direct Current (HVDC) transmission. Otherwise, if the power is transmitted via alternating current, the reactive power generated by the cable capacitance may cause an excessive over voltage in the middle of the transmission distance which requires unnecessary oversized cable voltage breakdown capability. The use of HVDC is usually required for transmission distance longer than 50 kilometers of submarine cables to be economical. The use of HVDC brings another advantage; it is capable of operating at variable frequency. The inland substation will be operated to 60 Hz synched with the grid, the offshore substation can be operated at variable frequency, thus allowing the wind power plant to be operated at constant Volt/Hz. In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated.

  18. Simplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation

    Directory of Open Access Journals (Sweden)

    Tongkun Lan

    2018-01-01

    Full Text Available AC (alternating current system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC simulations.

  19. Nelson Maculan Filho: cientista e educador

    Directory of Open Access Journals (Sweden)

    Ribeiro Celso Carneiro

    2003-01-01

    Full Text Available Este texto é um pequeno e merecido tributo ao Professor Nelson Maculan Filho por ocasião do seu 60masculine aniversário, em reconhecimento às suas grandes contribuições à Universidade brasileira. Como amigos, colaboradores e ex-alunos, ficamos sensibilizados e honrados com o convite feito pelo Professor Jayme Luiz Szwarcfiter para escrever este artigo. Carpe diem, querido amigo Maculan!

  20. Economic comparison of HVDC transmission and coal transport for Kalimantan - Sulawesi power system expansion

    International Nuclear Information System (INIS)

    Edwaren Liun

    2016-01-01

    Due to the load characteristics on many regions in Indonesia, the electrical system is often inefficient. In areas far from an interconnected network, for example isolated island, the choice of low cost fueled plants such as coal can not be applied, while the oil fueled has a very high generation cost and high burdened on subsidies. As a result, those area are still use oil fueled plant by limiting the generator flame time and consumers do not receive satisfactory service. This paper aims to analyze the extent to which the benefit of HVDC transmission system from Kalimantan to Sulawesi so that consumers could get better services and able to produce in order to improve their welfare. The method used in this analysis is a literature study and perform calculations based on existing formula. The result shows that in term of direct cost, HVDC system which covers transmission line, converter and loses cost, yield in a range of 0.46 - 0.60 USD¢/kWh for the capacity within 500 - 2000 Mwe. While coal transportation cost is in the range of 0.544 - 0.645 USD¢/kWh for long barge between 270 - 300 feet. Therefore, for the region of Indonesia which consist lots of islands and remote areas, power supply using HVDC transmission from area with more evolved electrical system could enable more economical, so that remote region also got excellent electrical services to improve the well-being and incomes of the population. (author)

  1. Nelson ja Rodney - inglaste erandlikud lahingulaevad / Sander Kingsepp

    Index Scriptorium Estoniae

    Kingsepp, Sander

    2006-01-01

    1922. aastal Washingtonis alla kirjutatud mereväerelvastuse lepe läks ajalukku äpardunud katsena võidurelvastamisele piir panna. Leppega ühinenud riigid hakkasid ilmutama veidra välimusega sõjalaevu, mille seas olid aukohal Briti alused "Nelson" ja "Rodney"

  2. The role of facts and HVDC in the future pan-European transmission system development

    NARCIS (Netherlands)

    L'Abbate, A.; Migliavacca, G.; Hager, U.; Rehtanz, C.; Ruberg, S.; Lopes Ferreira, H.M.; Fulli, G.; Purvins, A.

    2010-01-01

    The present paper focuses on FACTS (Flexible Alternating Current Transmission System) and HVDC (High Voltage Direct Current) transmission technologies. Particular attention is paid to different specific technical, economic and environmental features of these power electronics-based devices. Final

  3. Power-electronic asset characteristics for HVDC-connected offshore grids

    Energy Technology Data Exchange (ETDEWEB)

    Heising, C.; Meyer, D.; Bartelt, R. [Avasition GmbH, Dortmund (Germany); Koochack Zadeh, M.; Lebioda, T.J.; Jung, J. [TenneT Offshore GmbH, Bayreuth (Germany)

    2012-07-01

    Analysing offshore wind-farm applications as well as other converter-dominated grids, two key differences can be identified compared to conventional configurations: No relevant short-circuit power is available and no inertia is directly coupled to the AC grid. Within this paper, power-electronic asset characteristics for HVDC-connected offshore grids are presented which apply new principles allowing for better dynamic operation in the weak grids introduced. The capability is demonstrated using simulation results of an AC-multi-terminal system. (orig.)

  4. Nonlinear Control of Back-to-Back VSC-HVDC System via Command-Filter Backstepping

    Directory of Open Access Journals (Sweden)

    Jie Huang

    2017-01-01

    Full Text Available This paper proposed a command-filtered backstepping controller to improve the dynamic performance of back-to-back voltage-source-converter high voltage direct current (BTB VSC-HVDC. First, the principle and model of BTB VSC-HVDC in abc and d-q frame are described. Then, backstepping method is applied to design a controller to maintain the voltage balance and realize coordinated control of active and reactive power. Meanwhile, command filter is introduced to deal with the problem of input saturation and explosion of complexity in conventional backstepping, and a filter compensation signal is designed to diminish the adverse effects caused by the command filter. Next, the stability and convergence of the whole system are proved via the Lyapunov theorem of asymptotic stability. Finally, simulation results are given to demonstrate that proposed controller has a better dynamic performance and stronger robustness compared to the traditional PID algorithm, which also proves the effectiveness and possibility of the designed controller.

  5. Research on hybrid transmission mode for HVDC with optimal thermal power and renewable energy combination

    Science.gov (United States)

    Zhang, Jinfang; Yan, Xiaoqing; Wang, Hongfu

    2018-02-01

    With the rapid development of renewable energy in Northwest China, curtailment phenomena is becoming more and more serve owing to lack of adjustment ability and enough transmission capacity. Based on the existing HVDC projects, exploring the hybrid transmission mode associated with thermal power and renewable power will be necessary and important. This paper has proposed a method on optimal thermal power and renewable energy combination for HVDC lines, based on multi-scheme comparison. Having established the mathematic model for electric power balance in time series mode, ten different schemes have been picked for figuring out the suitable one by test simulation. By the proposed related discriminated principle, including generation device utilization hours, renewable energy electricity proportion and curtailment level, the recommendation scheme has been found. The result has also validated the efficiency of the method.

  6. HVDC: A key solution in future transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Heyman, Olof H.; Weimers, Lars; Bohl, Mie-Lotte

    2010-09-15

    With the transition of power grids, based on sustainable generation, HVDC is a key technology with new applications. This includes connection of remote wind parks and strengthening of existing AC grids. In addition, traditional applications, such as bulk hydropower transfer and interconnections between regions, play a major role in our transition to sustainable generation and the associated grids. The technology for regional grids with a limited number of nodes is already in place and commercial projects are commissioned. For extensive grids, development and verification are ongoing in parallel to industry standards being discussed in groups such as ENTSO-E and CIGRE.

  7. Dynamic Performance of an HVDC Link

    Directory of Open Access Journals (Sweden)

    S. A. ZIDI

    2005-09-01

    Full Text Available This paper presents the results of a simulation study on a 12 pulse HVDC (High Voltage Direct Current using a system in Matlab/Simulink. The object of the study is to investigate the steady state and dynamic performance of the system. First we examine response of current regulator after change in current reference in order to see the behavior of the controllers in controlling the desired current. Next, we present the digital simulation of a test system and show the response to a DC fault in the line and the AC fault at inverter side. The results are evaluated to enhance the recovery of the system from the disturbances for a full range of typical disturbances. The presented approach benefits from Simulink’s advantages in modeling and simulating dynamical systems.

  8. Score-Driven Nelson Siegel: Hedging Long-Term Liabilities

    NARCIS (Netherlands)

    R. Quaedvlieg (Rogier); P.C. Schotman (Peter)

    2016-01-01

    textabstractDue to its affine structure the Nelson-Siegel model for yield curves can be transformed to a factor model for excess bond returns. Hedging interest rate risk in this framework amounts to eliminating the factor exposure and minimizing the residual risk. Fitting the model directly on

  9. Second Order Cone Programming (SOCP) Relaxation Based Optimal Power Flow with Hybrid VSC-HVDC Transmission and Active Distribution Networks

    DEFF Research Database (Denmark)

    Ding, Tao; Li, Cheng; Yang, Yongheng

    2017-01-01

    The detailed topology of renewable resource bases may have the impact on the optimal power flow of the VSC-HVDC transmission network. To address this issue, this paper develops an optimal power flow with the hybrid VSC-HVDC transmission and active distribution networks to optimally schedule...... the generation output and voltage regulation of both networks, which leads to a non-convex programming model. Furthermore, the non-convex power flow equations are based on the Second Order Cone Programming (SOCP) relaxation approach. Thus, the proposed model can be relaxed to a SOCP that can be tractably solved...

  10. Power-hardware-in-the-loop test of VSC-HVDC connection for off-shore wind power plants

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Ranjan [Siemens Wind Power A/S, Brande (Denmark); Technical Univ. of Denmark (Denmark). Center for Electric Technology; Cha, Seung T.; Wu, Qiuwei; Rasmussen, Tonny W.; Oestergaard, Jacob [Technical Univ. of Denmark (Denmark). Center for Electric Technology; Jensen, Kim H. [Siemens Wind Power A/S, Brande (Denmark)

    2011-07-01

    This paper present a power-hardware-in-the-loop (PHIL) test of an off-shore wind power plant (WPP) interconnected to the on-shore grid via a VSC-HVDC connection. The intention of the PHIL test is to verify the hardware interaction and the control co-ordination between the plant side VSC of the HVDC system and the wind turbines within the WPP in order to ensure smooth operation of the WPP under both normal and fault operating condition. The PHIL test platform is comprised of a real time digital simulator (RTDS), a Spitzenberger Spies three phase 7,5 kW power amplifier, a purpose built VSC and a DC chopper. The WPP is simulated in the RTDS as a single full-scale wind turbine. The simulated WPP interacts with the WPP side VSC through the power amplifier. The interface between the RTDS and the power amplifier is done via an analogue GTAO I/O card of the RTDS and the input channel of the amplifier. The amplifier scales up the voltages at the point of connection of the WPP in the RTDS to the voltage level for the WPP side VSC. The WPP side VSC converter is equipped with a DC chopper. The test results show the successful control coordination between the WPP and the plant side VSC converter of the HVDC connection of the WPP. (orig.)

  11. Heat dissipation computations of a HVDC ground electrode using a supercomputer

    International Nuclear Information System (INIS)

    Greiss, H.; Mukhedkar, D.; Lagace, P.J.

    1990-01-01

    This paper reports on the temperature, of soil surrounding a High Voltage Direct Current (HVDC) toroidal ground electrode of practical dimensions, in both homogeneous and non-homogeneous soils that was computed at incremental points in time using finite difference methods on a supercomputer. Curves of the response were computed and plotted at several locations within the soil in the vicinity of the ground electrode for various values of the soil parameters

  12. Development and Testing of Physically-Based Methods for Filling Gaps in Remotely Sensed River Data

    Science.gov (United States)

    2011-09-30

    Filling Gaps in Remotely Sensed River Data Jonathan M. Nelson US Geological Survey National Research Program Geomorphology and Sediment Transport...the research work carried out under this grant are to develop and test two methods for filling in gaps in remotely sensed river data. The first...information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215

  13. ‘Magic Negro’, Saint or Comrade: Representations of Nelson Mandela in Film

    OpenAIRE

    Roger Bromley

    2014-01-01

    “In the late 1980s, Nelson Mandela stood alone against the apartheid state.” This comment taken from the DVD Box set cover of Nelson Mandela: From Freedom to History summarises the approach taken by many of the cinematic and televisual representations of Mandela. Linked with this is a statement by the CEO of Marriott which speaks of Mandela as “an individual who changed the arc of history through his or her singular contribution, not as a function of the era or the movement but because of wha...

  14. Development and Testing of Physically-Based Methods for Filling Gaps in Remotely Sensed River Data: Annual Report Year 2

    Science.gov (United States)

    2012-09-30

    near Deerlodge Park to support a USGS surface-water modeling study. Similar modeling projects on the San Joaquin and Sheboygan River were aided over...September 5-7, 2012, San Jose, Costa Rica, 8p. Nelson, J.M., McDonald, R.R., Kinzel, P.J., and Legleiter, C.J., 2011, Using computational models to...of the International Conference on Fluvial Hydraulics, September 5-7, 2012, San Jose, Costa Rica, 8p. *Nelson, J.M., McDonald, R.R., Kinzel, P.J

  15. Book Review: Nelson Mandela: A Jacana Pocket Biography ...

    African Journals Online (AJOL)

    Book Title: Nelson Mandela: A Jacana Pocket Biography. Author: Colin Bundy. Jacana: Auckland Park, 2015. 159 pp. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  16. Tailored sPP/Silica Nano composite for Eco friendly Insulation of Extruded HVDC Cable

    International Nuclear Information System (INIS)

    Dang, B.; He, J.; Hu, J.; Zhou, Y.

    2015-01-01

    Cross-linked polyethylene (XLPE) is a thermosetting material that cannot be recycled at the end of its lifetime. This study investigated the potential of syndiotactic polypropylene (sPP)/silica as an eco friendly extruded insulation system for HVDC cables. We investigated the morphology, Fourier transform infrared, and thermal, thermomechanical, and electrical behaviors of sPP modified with 0.5-3% nano silica. We found that the silica/sPP nano composite without cross-linking offered a suitable mechanical modulus at room temperature and sufficient intensity at high temperatures, and adding nano silica modified by a silane coupling agent to the sPP resulted in significant DC resistivity and space charge improvement. The optimal nano silica content in the sPP was determined by balancing the mechanical and thermomechanical characteristics and the DC resistivity. The sPP/silica nano composite reported here shows great potential as a candidate insulation material for future eco friendly extruded HVDC cables.

  17. 78 FR 66353 - EAM Nelson Holdings, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2013-11-05

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-2349-000] EAM Nelson Holdings, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket Section 204 Authorization This is a supplemental notice in the above-referenced proceeding, of EAM Nelson...

  18. Gamma Knife Radiosurgery for Cushing's Disease and Nelson's Syndrome

    Czech Academy of Sciences Publication Activity Database

    Marek, J.; Ježková, J.; Hána, V.; Kršek, M.; Liščák, R.; Vladyka, V.; Pecen, Ladislav

    2015-01-01

    Roč. 18, č. 3 (2015), s. 376-384 ISSN 1386-341X Institutional support: RVO:67985807 Keywords : Cushing's disease * Nelson's syndrome * Gamma knife surgery * Pituitary adenoma Subject RIV: FB - Endocrinology, Diabetology, Metabolism, Nutrition Impact factor: 3.407, year: 2015

  19. High-voltage direct current (HVDC) transmission - a key technology for our power supply

    International Nuclear Information System (INIS)

    Dorn, J.

    2016-01-01

    The phasing-out of nuclear power in some countries and the aspirations of reducing carbon dioxide emissions have far-reaching implications for electric power generation in Europe. In the future, renewable electricity generation will account for a considerable share of the energy mix, but this type of production is often far from the load centers. In Germany, for example, large quantities of wind energy are already generated in the north and in the North Sea, but large load centers are located several hundred kilometers south of there. This requires an expansion of the transmission network with innovative solutions. High-voltage direct-current (HVDC) transmission plays an important role, since it brings a number of advantages over conventional AC technology and makes certain requirements feasible, for example Cable transmission over longer distances. The lecture presents the advantages of HVDC, the semiconductors used as well as the basic functions and typical performance of the used converter topopologies. The plant configurations and main components are illustrated using current projects. (rössner) [de

  20. Design of protective inductors for HVDC transmission line within DC grid offshore wind farms

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    in the HVDC link between the offshore station and the onshore station. The transient characteristics of the transmission system are analyzed in detail. The criteria of selecting protective inductors are proposed to effectively limit the short-circuit current and avoid the damage to the converters. A dc grid...

  1. Modeling of HVDC System to Improve Estimation of Transient DC Current and Voltages for AC Line-to-Ground Fault—An Actual Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Dohoon Kwon

    2017-10-01

    Full Text Available A new modeling method for high voltage direct current (HVDC systems and associated controllers is presented for the power system simulator for engineering (PSS/E simulation environment. The aim is to improve the estimation of the transient DC voltage and current in the event of an AC line-to-ground fault. The proposed method consists primary of three interconnected modules for (a equation conversion; (b control-mode selection; and (c DC-line modeling. Simulation case studies were carried out using PSS/E and a power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC model of the Jeju– Haenam HVDC system in Korea. The simulation results are compared with actual operational data and the PSCAD/EMTDC simulation results for an HVDC system during single-phase and three-phase line-to-ground faults, respectively. These comparisons show that the proposed PSS/E modeling method results in the improved estimation of the dynamic variation in the DC voltage and current in the event of an AC network fault, with significant gains in computational efficiency, making it suitable for real-time analysis of HVDC systems.

  2. Nelson's syndrome in pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Surrey, E.S.; Chang, R.J.

    1985-10-01

    The therapeutic considerations in the management of Nelson's syndrome in a 29 year old primigravida are described. CT scans revealed a 2-cm solid pituitary lesion with suprasellar extension and chiasmatic encroachment. A transsphenoidal hypophysectomy was performed to remove a eosinophilic pituitary adenoma. The patient's symptoms improved following surgery. Fetal growth was followed by ultrasound and a female infant was delivered by cesarean section. Follow-up CT scan 2 weeks after delivery revealed no evidence of tumor recurrence.

  3. The search for a more human face for Nelson Mandela: An urgent task

    OpenAIRE

    Tinyiko Maluleke

    2015-01-01

    For many reasons, reflecting on the life of Nelson Mandela is a precarious exercise. If Mandela is a symbol of the resilience of the human spirit under trying conditions, he is also a symbol that is appropriated in various ways – helpful and unhelpful – by various people. This article explores some of the unhelpful ways in which the name and person of Nelson Mandela is invoked. In particular, the article looks at the hagiographical orientation of several reflections on Mandela, cautioning ...

  4. Multilevel Modular Converter for VSC-HVDC Transmission Applications: Control and Operational Aspects

    DEFF Research Database (Denmark)

    Gnanarathna, Udana N.; Gole, Aniruddha M.; Chaudhary, Sanjay Kumar

    2010-01-01

    Control methods for a new class of converter, the multilevel modular converter (MMC), recently introduced for HVDC transmission are discussed. The paper discusses converter-level controls including firing pulse generation and capacitor voltage balancing. It also covers higher level controls...... for incorporating the converter into a larger power network, with a weak ac receiving end. The performance behavior is studied using electromagnetic transients simulation....

  5. Convergence of Nelson diffusions

    International Nuclear Information System (INIS)

    Dell'Antonio, G.; Posilicano, A.

    1991-01-01

    Let ψ t , ψ t n , n≥1, be solutions of Schroedinger equations with potentials form-bounded by -1/2 Δ and initial data in H 1 (R d ). Let P, P n , n≥1, be the probability measures on the path space Ω=C(R + , R d ) given by the corresponding Nelson diffusions. We show that if {ψ t n } n≥1 converges to ψ t in H 2 (R d ), uniformly in t over compact intervals, then {P n } n≥1 converges to P in total variation. Moreover, if the potentials are in the Kato class K d , we show that the above result follows from H 1 -convergence of initial data, and K d -convergence of potentials. (orig.)

  6. PREDIKSI PUNCAK KEMATANGAN BUAH NAGA MELALUI PENGUKURAN GULA REDUKSI DENGAN METODE NELSON-SOMOGYI

    Directory of Open Access Journals (Sweden)

    Alimuddin -

    2016-01-01

    Full Text Available Prediction of dragon fruit maturation peak by measuring reductor sugar with nelson-somogyi method have been done. Prediction was done by using three modes which are experimental result, regression model and first derivation. Age of the fruit which used in this research were 1, 3, 5 and 7 weeks old. Based on the result of this research can be concluded that maturation peak of dragon fruit happens at between 5 until 6 weeks old. Keywords: Dragon Fruit, Reductor Sugar and Nelson-Somogyi Method.

  7. Corner Office Interview: SirsiDynix's Rautenstrauch and Nelson

    Science.gov (United States)

    Rapp, David; Fialkoff, Francine

    2010-01-01

    This article presents an interview with SirsiDynix CEO Gary M. Rautenstrauch and newly appointed VP of library relations Berit Nelson about some of the issues that have been roiling the ILS world and the company itself, among them the recent consolidation of SirsiDynix's offices, customer service, the state of library budgets, the rise of ebooks…

  8. Kunda "liumägi" / Ago Kastemäe, Huviklubi Nelson

    Index Scriptorium Estoniae

    Kastemäe, Ago

    2014-01-01

    Millistel tingimustel on võimalik Kunda jõel paiknevast hüdroelektrijaama tammist süsta või raftiga alla sõita. Huviklubi Nelson pakub koostöös Lontova Seikluspargiga Kunda jõel juhendajatega raftimatku

  9. Field distribution on an HVDC wall bushing during laboratory rain tests

    International Nuclear Information System (INIS)

    Lampe, W.; Wikstrom, D.; Jacobson, B.

    1991-01-01

    This paper reports that an efficient counter-measure to suppress flashovers across HVDC wall bushings is to make their surfaces hydrophobic. This laboratory investigation reports the measured electric field along such a bushing under different environmental conditions. A significantly reduced radial field strength has been found for the hydrophobic bushing. Moreover, the total field strength distribution becomes almost independent of the prevailing dry zone. The flashover voltage for bushings with a hydrophobic surface is therefore significantly increased

  10. Analyzing the term structure of interest rates using the dynamic Nelson-Siegel model with time-varying parameters

    NARCIS (Netherlands)

    Koopman, S.J.; Mallee, M.I.P.; van der Wel, M.

    2010-01-01

    In this article we introduce time-varying parameters in the dynamic Nelson-Siegel yield curve model for the simultaneous analysis and forecasting of interest rates of different maturities. The Nelson-Siegel model has been recently reformulated as a dynamic factor model with vector autoregressive

  11. Examination of fault ride-through methods for off-shore wind farms connected to the grid through VSC-based HVDC transmission

    Energy Technology Data Exchange (ETDEWEB)

    Karaagac, U.; Mahseredjian, J.; Saad, H. [Ecole Polytechnique de Montreal, QC (Canada); Jensen, S.; Cai, L. [REpower Systems AG, Hamburg (Germany)

    2012-07-01

    The fault ride-through (FRT) performance of offshore wind farms (OWFs) is a challenging task when the OWF is connected to the onshore ac grid through a voltage source converter (VSC) based HVDC transmission system. The injected power from the OWF cannot be reduced by the offshore VSC during onshore ac faults and this causes a fast increase in the dc network voltage. Without any special FRT method, the dc network voltage may increase up to intolerable levels and cause operation of dc overvoltage protection. This paper compares various FRT methods based on fast reduction of power generation in OWFs. In addition, this paper proposes an improved FRT method based on controlled voltage drop for output power reduction in OWFs. The proposed improvement reduces mechanical stress on the wind turbine (WT) drive train, and electrical stress on the insulated gate bipolar transistors (IGBTs) of the HVDC and doubly-fed induction generator (DFIG) converters. Practical onshore ac fault scenarios are simulated for an OWF composed of DFIG type WTs and connected to a practical ac grid through a point-to-point modular multilevel converter (MMC) based HVDC system. (orig.)

  12. Power-flow control and stability enhancement of four parallel-operated offshore wind farms using a line-commutated HVDC link

    DEFF Research Database (Denmark)

    Wang, Li; Wang, Kuo-Hua; Lee, Wei-Jen

    2010-01-01

    This paper presents an effective control scheme using a line-commutated high-voltage direct-current (HVDC) link with a designed rectifier current regulator (RCR) to simultaneously perform both power-fluctuation mitigation and damping improvement of four parallel-operated 80-MW offshore wind farms...... delivering generated power to a large utility grid. The proposed RCR of the HVDC link is designed by using modal control theory to contribute adequate damping to the studied four offshore wind farms under various wind speeds. A systematic analysis using a frequency-domain approach based on eigenvalue...... characteristics to the studied offshore wind farms under various wind speeds but also effectively mitigate power fluctuations of the offshore wind farms under wind-speed disturbance conditions....

  13. Fault ride-through and grid support of permanent magnet synchronous generator-based wind farms with HVAC and VSC-HVDC transmission systems

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2012-01-01

    This paper describes fault ride-through and grid support of offshore wind farms based on permanent magnet synchronous generator (PMSG) wind turbines connected to the onshore AC network through two alternative transmission systems: high voltage AC (HVAC) or high voltage DC (HVDC) based on voltage...... source converters (VSC). The proposed configurations of the PMSG-based offshore wind farm and VSC-based HVDC are given as well as their control strategies under both steady state and fault state. The PMSG-based offshore wind farm is integrated into a test power transmission system via either HVAC or VSC...

  14. High-performance HVDC transmission over long distances; Hochleistungsuebertragung ueber grosse Entfernungen mit hochgespanntem Gleichstrom

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U. [PreussenElektra AG, Hannover (Germany)

    1998-12-31

    High-voltage DC transmission is a world-wide established technology for low-cost transmission of large amounts of electricity over long distances. Thanks to HVDC transmission, large amounts of electricity can now for the first time also be transmitted over long distances via ocean cable, something that cannot be done with AC power cables. HVDC transmission is independent of grid frequencies and can link grids of different frequency and different quality of frequency. Interconnected grids coupled via DC circuits can exploit additional technical and economic advantages such as mutual supply of power reserves, balancing of peak load, and modulation of active and reactive power. (orig.) [Deutsch] Die Hochspannungs-Gleichstromuebertragung (HGUe) ist eine weltweit etablierte Technik zur kostenguenstigen Uebertragung grosser elektrischer Leistungen ueber grosse Entfernungen. Sie schafft erstmals die Moeglichkeit, auch mittels Seekabel grosse Leistungen ueber Entfernungen zu uebertragen, die mit der Drehstromtechnik nicht moeglich sind. HGUeist unabhaengig von den Netzfrequenzen und kann Netze unterschiedlicher Frequenz und Frequenzguete miteinander verbinden. Ueber Gleichstromkreise gekuppelte Verbundnetze koennen zusaetzliche technische und wirtschaftliche Vorteile wie gegenseitige Bereitstellung von Kraftwerksreserven, Spitzenlastausgleich sowie Wirk- und Blindleistungsmodulation nutzt. (orig.)

  15. Modelling and Simulation of VSC-HVDC Connection for Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2009-01-01

    This paper describes the modelling and simulation of offshore wind power plants (WPP) connected to the onshore power system grid by VSC based HVDC transmission. Offshore wind power plant is modelled with several wind turbine generators connected to two separate collector buses with their own plant...... wind turbines. Simulation of power ramping up and down as well as steady state operation has been demonstrated. As an additional case, the primary reserve control logic has been implemented and simulated in PSCAD model....

  16. Nelson Mandela and the Power of Ubuntu

    Directory of Open Access Journals (Sweden)

    Claire E. Oppenheim

    2012-04-01

    Full Text Available Nelson Mandela dedicated his life to fighting for the freedom of his South African kin of all colors against the institution of apartheid. He spent twenty-seven years fighting from within prison, only gaining his freedom when his fellow South Africans could claim it as well. This article demonstrates how his faith, his spiritual development and his noble purpose can be conceptualized through the lens of Ubuntu: the African ethic of community, unity, humanity and harmony.

  17. Rebuttal to Nelson et al. 'Response to Bodin and Grote regarding postdoctoral recruitment in clinical neuropsychology'.

    Science.gov (United States)

    Bodin, Doug; Grote, Christopher L

    2016-07-01

    Nelson et al. provided a response to our commentary on the postdoctoral match in clinical neuropsychology. In this brief rebuttal, we will focus on statements from Nelson et al. that we believe are factual inaccuracies or misunderstandings of some of the points we made in our commentary. In addition, we will comment briefly on the proposed guidelines offered in their response.

  18. accuracy of nelson and best guess formulae in estimation of weights

    African Journals Online (AJOL)

    treatment decisions including nutritional status assessment, drug ... weight estimations in infants and children aged 6-11 years. ... include: the Nelson formulae,7,8 Advanced Paediatric ... measured according to the Center for Disease Control.

  19. A Good Time: A Conversation with C. Michael Nelson

    Science.gov (United States)

    Zabel, Robert; Kaff, Marilyn; Teagarden, Jim

    2015-01-01

    C. Michael Nelson began his special education career as a teacher of adolescents with learning and behavior disorders. He has worked as a child psychologist and as a professor with the Department of Special Education and Rehabilitation Counseling at the University of Kentucky. He coordinated the graduate Personnel Preparation Program for Teachers…

  20. A Message from Nelson Mandela to the Youth of America.

    Science.gov (United States)

    Mandela, Nelson

    1995-01-01

    Presents a message to young people from Nelson Mandela, president of South Africa. Calls for a bridge between the youth of Africa and the United States. Asserts that racial divisions in the United States are major social issues that must be solved. (CFR)

  1. Romance and Freedom: Nelson and Winnie Mandela’s Politics of Gender in Three Post-Apartheid Novels

    Directory of Open Access Journals (Sweden)

    Lorenzo Mari

    2014-11-01

    Full Text Available This paper aims to retrace the influence of the politics of gender enacted by Nelson and Winnie Mandela on post-apartheid gender relationships, as represented in three novels: Phaswane Mpe’s Welcome to Our Hillbrow (2001, Njabulo Ndebele’s The Cry of Winnie Mandela (2003 and Lewis Nkosi’s Mandela’s Ego (2006. Recently, Nelson and Winnie Mandela’s marriage has been also described as the “unusual founding-family romance” (Munro 2014 of the post-apartheid nation. Their marriage lasted from 1958 to 1992, including, thus, the last decades of the anti-apartheid struggle, as well as the demise of the apartheid regime. Their separation, which was due in the first place to Nelson Mandela’s imprisonment and, later, to their divorce, eventually marked the disruption of this founding-family romance, making it “unusual”. As a consequence, the deconstructive take on Nelson Mandela’s fatherhood and masculinity and Winnie Mandela’s femininity and motherhood which is enacted in the three novels also allows to reassess the possibility of that “founding-family romance”, envisioning an alternative understanding of the origins of the post-apartheid South African nation.

  2. Limiting electric fields of HVDC overhead power lines.

    Science.gov (United States)

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  3. John Nelson Darby: His Contributions to Evangelical Christian Higher Education

    Science.gov (United States)

    Sutherland, Winston Terrance

    2010-01-01

    The study reported in this article focused on the contributions of John Nelson Derby to biblical hermeneutics and contemporary eschatological thought. Darby continues to exert a great influence on Christianity, particularly conservative evangelical Christianity. This research provides a discussion of Darby's contributions to contemporary…

  4. A Pilot Directional Protection for HVDC Transmission Line Based on Relative Entropy of Wavelet Energy

    Directory of Open Access Journals (Sweden)

    Sheng Lin

    2015-07-01

    Full Text Available On the basis of analyzing high-voltage direct current (HVDC transmission system and its fault superimposed circuit, the direction of the fault components of the voltage and the current measured at one end of transmission line is certified to be different for internal faults and external faults. As an estimate of the differences between two signals, relative entropy is an effective parameter for recognizing transient signals in HVDC transmission lines. In this paper, the relative entropy of wavelet energy is applied to distinguish internal fault from external fault. For internal faults, the directions of fault components of voltage and current are opposite at the two ends of the transmission line, indicating a huge difference of wavelet energy relative entropy; for external faults, the directions are identical, indicating a small difference. The simulation results based on PSCAD/EMTDC show that the proposed pilot protection system acts accurately for faults under different conditions, and its performance is not affected by fault type, fault location, fault resistance and noise.

  5. Geothermal electric power generation in Iceland for the proposed Iceland/United Kingdom HVDC power link

    International Nuclear Information System (INIS)

    Hammons, T.J.; Palmason, G.; Thorhallsson, S.

    1991-01-01

    The paper reviews geothermal electric power potential in Iceland which could economically be developed to supplement hydro power for the proposed HVDC Power Link to the United Kingdom, and power intensive industries in Iceland, which are envisaged for development at this time. Technically harnessable energy for electricity generation taking account of geothermal resources down to an assumed base depth, temperature distribution in the crust, probable geothermal recovery factor, and accessibility of the field, has been assessed. Nineteen known high-temperature fields and 9 probable fields have been identified. Technically harnessable geo-heat for various areas is indicated. Data on high temperature fields suitable for geothermal electric power generation, and on harnessable energy for electric power generation within volcanic zones, is stated, and overall assessments are made. The paper then reviews how the potential might be developed, discussing preference of possible sites, and cost of the developments at todays prices. Cost of geothermal electric power generation with comparative costs for hydro generation are given. Possible transmission system developments to feed the power to the proposed HVDC Link converter stations are also discussed

  6. Coordinated Voltage Control Scheme for VSC-HVDC Connected Wind Power Plants

    DEFF Research Database (Denmark)

    Guo, Yifei; Gao, Houlei; Wu, Qiuwei

    2017-01-01

    This paper proposes a coordinated voltage control scheme based on model predictive control (MPC) for voltage source converter‐based high voltage direct current (VSC‐HVDC) connected wind power plants (WPPs). In the proposed scheme, voltage regulation capabilities of VSC and WTGs are fully utilized...... and optimally coordinated. Two control modes, namely operation optimization mode and corrective mode, are designed to coordinate voltage control and economic operation of the system. In the first mode, the control objective includes the bus voltages, power losses and dynamic Var reserves of wind turbine...

  7. Capacitor voltage ripple reduction and arm energy balancing in MMC-HVDC

    DEFF Research Database (Denmark)

    Parikh, Harsh; Martin-Loeches, Ruben Sánches; Tsolaridis, Georgios

    2016-01-01

    Modular Multilevel Converters are emerging and widely used in HVDC applications. However, the submodule capacitors are still large and the energy balancing under unbalanced conditions is a challenge. In this paper, an analytical model focusing on the energy stored in the capacitors and voltage...... variations is utilized in order to achieve better performance. By injecting a second order harmonic component into the circulating current, the energy variation and consequently the capacitor voltage ripple is reduced allowing for a capacitor size reduction. At the same time, an arm energy balancing...

  8. The struggle for Sunday lunch: gastropolitics in the life of Nelson Mandela.

    Science.gov (United States)

    Trapido, Anna

    2011-01-01

    This paper explores the political, economic, and social life of Nelson Mandela through his food choices from 1918 to the present. A description of the minutiae of one particular 1950s Sunday lunch is used to examine the broader role of first colonial and later apartheid legislation in determining the dietary choices and options of South Africans past and present. How such policies shaped attitudes and access to Nelson Mandela’s ancestral Xhosa cuisine is assessed. The long-term cultural, economic, and political impact of a lack of access to core indigenous African ingredients is evaluated. Most of all this paper offers a snapshot portrayal of two families (one white, one black) trying to sustain a normal friendship within a grossly abnormal society.

  9. Setting up the Nelson Mandela centre of memory and commemoration

    African Journals Online (AJOL)

    This article aims to outline the process of the audits, highlight the issues involved in the development of the web archive, as well as provide details on the development of the database architecture. Keywords: centre of memory and commemoration, Constitution Hill Heritage Site, Nelson Mandela Foundation, South Africa

  10. A rare and cryptic endemic of the Central Rocky Mountains, U.S.A: The distribution of the Arapahoe snowfly, Arsapnia arapahoe (Nelson & Kondratieff, 1988) (Plecoptera: Capniidae)

    Science.gov (United States)

    Fairchild, Matthew P.; Belcher, Thomas P.; Zuellig, Robert E.; Vieira, Nicole K.M.; Kondratieff, Boris C.

    2017-01-01

    The Arapahoe snowfly, Arsapnia arapahoe (Nelson & Kondratieff, 1988) (Plecoptera: Capniidae) is a candidate species warranted for listing under the Endangered Species Act. Prior to this study, A. arapahoe was known from only two tributaries of the Cache la Poudre River in Larimer County, Colorado: Young Gulch and Elkhorn Creek. The objectives of this study were to determine the distribution of this endemic stonefly, and to identify sympatric species as possible surrogate indicators of its occurrence. Eighty-four streams were sampled within the expected geographical range and emergence time-period from 2013 to 2017. Adults of A. arapahoe were discovered in 19 first-, second-, and fourth-order streams beyond the original type localities tributary to the Cache la Poudre River. The new and recently recorded localities were discovered in the Big Thompson River, St. Vrain River, Boulder Creek, and Upper South Platte River Watersheds. Two species, A. decepta (Banks, 1897) and Capnia gracilaria Claassen, 1924, always co-occurred with A. arapahoe, suggesting this species pair may serve as a surrogate indicator of suitable stream habitat for A. arapahoe. Suggestions for future investigation into the distribution, life-history, and habitat of A. arapahoe are presented to aid the conservation of this rare and endemic Colorado stonefly.

  11. Assessment of environmental impact of HVDC power lines in terms of corona currents

    International Nuclear Information System (INIS)

    Tikhodeev, N.N.

    1997-01-01

    Corona loss measurements were made on a HVDC power transmission line to evaluate current density. Ion currents were obtained from unipolar and bipolar 400 to 1000 kV DC test lines. A numerical solution was proposed for assessing the maximum current density of unipolar corona currents near the lines. A larger ground clearance of line conductors was proposed as being the most effective way of lowering the current density. 11 refs., 2 tabs., 4 figs

  12. Remarks on an algebraic semantics for paraconsistent Nelson's logic

    Directory of Open Access Journals (Sweden)

    Manuela Busaniche

    2011-06-01

    Full Text Available In the paper Busaniche and Cignoli (2009 we presented a quasivariety of commutative residuated lattices, called NPc-lattices, that serves as an algebraic semantics for paraconsistent Nelson's logic. In the present paper we show that NPc-lattices form a subvariety of the variety of commutative residuated lattices, we study congruences of NPc-lattices and some subvarieties of NPc-lattices.

  13. John Nelson Darby: Scholarship that Influenced the Bible College Movement

    Science.gov (United States)

    Sutherland, Winston Terrance

    2010-01-01

    The study reported in this article focused on the scholastic life of John Nelson Darby and his contributions to the Bible college movement. Darby continues to exert a great influence on Christianity, particularly conservative evangelical Christianity. This research provides a discussion of the forces that conspired to shape the direction of…

  14. Special article: Horace Nelson MD, John Webster LDS--unrecognized Canadian anesthesia pioneers.

    Science.gov (United States)

    Craig, Douglas; Chartrand, Daniel

    2014-03-01

    The timing of the earliest reported ether anesthetics in early 1847, in regions to become Canada in July 1867, was examined using information from on-line and library-based sources. Previous authors had identified the first reported ether anesthetic given by a visiting American dentist in January 1847 in Saint John, New Brunswick. Nevertheless, they had reported three different anesthetics as the second occurrence - which would denote the first anesthetic given by a resident of Canada. We confirmed that there were no reports of ether anesthetics being given in Canada before that reported on January 18, 1847 in Saint John. The information available for our review indicates that the second ether anesthetic, and the first by a Canadian, was given in Montreal by a dentist, Dr. John Horatio Webster, on February 20, 1847. The surgical assistant for that operation, Dr. Horace Nelson, later reported on animal and human experiments with ether, which he had led in Montreal starting in January 1847. Earlier authors, who may not have had access to the information now available, came to incorrect conclusions about the first ether anesthetic reported to have been given by a Canadian. Current information indicates that John Webster gave the first reported anesthetic in Montreal on February 20, 1847 following experiments with ether led by Horace Nelson. Both Webster and Nelson deserve recognition as Canadian anesthesia pioneers.

  15. Preliminary report on the Nelson and Radovan copper prospects, Nizina district, Alaska

    Science.gov (United States)

    Sainsbury, C.J.

    1952-01-01

    Renewed copper exploration by Alaska Copper Mines, Incorporated, at the Nelson and Radovan prospects, Nizina district, Alaska, led the Geological Survey in 1951 to map in detail the Nelson fault block, and to re-examine the old workings. In addition, two new prospects were studied. The Nelson fault block is cut by many dominantly strike-slip faults of small displacement, and by bedding faults. Slickensided chalcocite shows post-mineral movement, and chalcocite veinlet in a filled solution cavity indicates that some of the chalcocite is secondary, perhaps very recent. Structural relations indicate two overthrust faults cut the block. The Radovan Greenstone prospect shows massive chalcocite, up to 3 feet wide, in a silicified, epidotized fault zone in the Nikolai greenstone. Ore indicated by surface exposures may amount to 450 tons of chalcocite. The Radovan Low-Contact prospect is on a continuation of the same fault approximately 3 miles southwest of the Greenstone prospect, and 150 feet above the contact of the Nikolai greenstone and the overlying Chitistone limestone. Limonite staining is widespread in bedding planes and small faults near the fault zone; mineralization in the fault zone consists of pyrite, chalcocite, bornite, malachite, realgar, orpiment and stibnite. The sulphides in the fault zone, plus the widespread silicification and epidotization indicate a strong zone of hydrothermal activity which merits extensive prospecting.

  16. Hard- and software of real time simulation tools of Electric Power System for adequate modeling power semiconductors in voltage source convertor based HVDC and FACTS

    Directory of Open Access Journals (Sweden)

    Ufa Ruslan A.

    2014-01-01

    Full Text Available The motivation of the presented research is based on the needs for development of new methods and tools for adequate simulation of Flexible Alternating Current Transmission System (FACTS devices and High Voltage Direct Current Transmission (HVDC system as part of real electric power systems (EPS. For that, a hybrid approach for advanced simulation of the FACTS and HVDC based on Voltage Source is proposed. The presented simulation results of the developed hybrid model of VSC confirm the achievement of the desired properties of the model and the effectiveness of the proposed solutions.

  17. Grid-connection of offshore wind farms using VSC-HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xiaofan; Dessaint, Louis A. [Ecole de Technologie Superieure, Montreal, QC (Canada). Dept. of Electrical Engineering; Gagnon, Richard [Hydro-Quebec Research Institute, Montreal, QC (Canada)

    2011-07-01

    In this paper, the structure of variable speed PMSG-based offshore wind farms connected to the grid through VSC-HVDC link is presented. And the system models are developed. Also, the corresponding control strategy for this system is proposed. The control objective of the generator side VSC is to achieve the optimal wind power by adjusting the speed of permanent magnet synchronous generator, while the grid side VSC is to maintain DC voltage constant. Furthermore, a case study of 100MW offshore wind farm consisting of 50 individual 2MW PSMG-based wind turbines is developed in MATLAB/SimPowerSystems. Simulation results show the proposed scheme works well. (orig.)

  18. The effect of FRT behavior of VSC-HVDC-connected offshore wind power plants on AC/DC system dynamics

    NARCIS (Netherlands)

    van der Meer, A.A.; Ndreko, M.; Gibescu, M.; van der Meijden, M.A.M.M.

    2016-01-01

    Future power systems will contain more converter-based generation, among which are the voltage-source converter-high-voltage direct-current (VSC-HVDC)-connected offshore wind power plants (WPP). Their interaction with the onshore system influences power system dynamics in the transient stability

  19. Advanced fault ride-through control of DFIG based wind turbines including grid connection via VSC-HVDC

    Energy Technology Data Exchange (ETDEWEB)

    Feltes, Christian

    2012-07-01

    With the growing renewable energy share in the power generation mix it becomes inevitable that also these new generation technologies participate on the provision of grid services to guarantee stable operation of the grid, especially when one considers the decreasing number of conventional power plants in operation as a result of the expansion of wind based generation plants. These so-called ancillary services include frequency / active power control, voltage / reactive power control and fault ride-through (FRT) with fast voltage control and are stipulated in modern grid codes. In the context of this thesis advanced control algorithms have been developed for wind turbines based on doubly-fed induction generator (DFIG) to allow safe FRT during symmetrical and unsymmetrical faults. This covers the control for conventional AC grid connection as well as for the connection through voltage source converter (VSC) based high voltage direct current transmission (HVDC). Currently, the DFIG is the most used generator technology in modem wind turbines, since it combines a relatively simple slip-ring induction machine with a frequency converter rated to only approx. 30% of the total power. This makes the DFIG a cost-effective concept, which offers a variable speed range and a high degree of flexibility in control. However, due to the direct coupling of the generator stator circuit to the grid, grid faults are a special challenge for the frequency converter, its protection circuits and control algorithms. As base for the detailed evaluation of the impact of grid faults to the DFIG, this thesis contains the analytical derivation of the DFIG short circuit currents under consideration of frequency converter control. The DFIG concept presented in this thesis makes use of a DC chopper in the frequency converter, which allows safe FRT with grid voltage support through both converter sides. The developed control contains a new algorithm for a clear separation and control of positive

  20. Application of Grey Wolf Optimizer Algorithm for Optimal Power Flow of Two-Terminal HVDC Transmission System

    Directory of Open Access Journals (Sweden)

    Heba Ahmed Hassan

    2017-01-01

    Full Text Available This paper applies a relatively new optimization method, the Grey Wolf Optimizer (GWO algorithm for Optimal Power Flow (OPF of two-terminal High Voltage Direct Current (HVDC electrical power system. The OPF problem of pure AC power systems considers the minimization of total costs under equality and inequality constraints. Hence, the OPF problem of integrated AC-DC power systems is extended to incorporate HVDC links, while taking into consideration the power transfer control characteristics using a GWO algorithm. This algorithm is inspired by the hunting behavior and social leadership of grey wolves in nature. The proposed algorithm is applied to two different case-studies: the modified 5-bus and WSCC 9-bus test systems. The validity of the proposed algorithm is demonstrated by comparing the obtained results with those reported in literature using other optimization techniques. Analysis of the obtained results show that the proposed GWO algorithm is able to achieve shorter CPU time, as well as minimized total cost when compared with already existing optimization techniques. This conclusion proves the efficiency of the GWO algorithm.

  1. A generalization of Fenyes-Nelson stochastic model of quantum mechanics

    International Nuclear Information System (INIS)

    Davidson, M.

    1979-01-01

    It is shown that the stochastic model of Fenyes and Nelson can be generalized in such a way that the diffusion constant of the Markov theory becomes a free parameter. This extra freedom allows one to identify quantum mechanics with a class of Markov processes with diffusion constants varying from 0 to infinity. (Auth.)

  2. Romance and Freedom: Nelson and Winnie Mandela’s Politics of Gender in Three Post-Apartheid Novels

    OpenAIRE

    Mari, Lorenzo

    2014-01-01

    This paper aims to retrace the influence of the politics of gender enacted by Nelson and Winnie Mandela on post-apartheid gender relationships, as represented in three novels: Phaswane Mpe’s Welcome to Our Hillbrow (2001), Njabulo Ndebele’s The Cry of Winnie Mandela (2003) and Lewis Nkosi’s Mandela’s Ego (2006). Recently, Nelson and Winnie Mandela’s marriage has been also described as the “unusual founding-family romance” (Munro 2014) of the post-apartheid nation. Their marriage lasted fr...

  3. Relative localization in wireless sensor networks for measurement of electric fields under HVDC transmission lines.

    Science.gov (United States)

    Cui, Yong; Wang, Qiusheng; Yuan, Haiwen; Song, Xiao; Hu, Xuemin; Zhao, Luxing

    2015-02-04

    In the wireless sensor networks (WSNs) for electric field measurement system under the High-Voltage Direct Current (HVDC) transmission lines, it is necessary to obtain the electric field distribution with multiple sensors. The location information of each sensor is essential to the correct analysis of measurement results. Compared with the existing approach which gathers the location information by manually labelling sensors during deployment, the automatic localization can reduce the workload and improve the measurement efficiency. A novel and practical range-free localization algorithm for the localization of one-dimensional linear topology wireless networks in the electric field measurement system is presented. The algorithm utilizes unknown nodes' neighbor lists based on the Received Signal Strength Indicator (RSSI) values to determine the relative locations of nodes. The algorithm is able to handle the exceptional situation of the output permutation which can effectively improve the accuracy of localization. The performance of this algorithm under real circumstances has been evaluated through several experiments with different numbers of nodes and different node deployments in the China State Grid HVDC test base. Results show that the proposed algorithm achieves an accuracy of over 96% under different conditions.

  4. Relative Localization in Wireless Sensor Networks for Measurement of Electric Fields under HVDC Transmission Lines

    Directory of Open Access Journals (Sweden)

    Yong Cui

    2015-02-01

    Full Text Available In the wireless sensor networks (WSNs for electric field measurement system under the High-Voltage Direct Current (HVDC transmission lines, it is necessary to obtain the electric field distribution with multiple sensors. The location information of each sensor is essential to the correct analysis of measurement results. Compared with the existing approach which gathers the location information by manually labelling sensors during deployment, the automatic localization can reduce the workload and improve the measurement efficiency. A novel and practical range-free localization algorithm for the localization of one-dimensional linear topology wireless networks in the electric field measurement system is presented. The algorithm utilizes unknown nodes’ neighbor lists based on the Received Signal Strength Indicator (RSSI values to determine the relative locations of nodes. The algorithm is able to handle the exceptional situation of the output permutation which can effectively improve the accuracy of localization. The performance of this algorithm under real circumstances has been evaluated through several experiments with different numbers of nodes and different node deployments in the China State Grid HVDC test base. Results show that the proposed algorithm achieves an accuracy of over 96% under different conditions.

  5. Active Power Control with Undead-Band Voltage & Frequency Droop for HVDC Converters in Large Meshed DC Grids

    DEFF Research Database (Denmark)

    Vrana, Til Kristian; Zeni, Lorenzo; Fosso, Olav Bjarte

    A new control method for large meshed HVDC grids has been developed, which helps to keep the active power balance at the AC and the DC side. The method definition is kept wide, leaving the possibility for control parameter optimisation. Other known control methods can be seen as specific examples...

  6. Improvement of Wind Energy Production through HVDC Systems

    Directory of Open Access Journals (Sweden)

    Morris Brenna

    2017-01-01

    Full Text Available Variable and non-programmable resources, such as solar and wind, have undergone a stunning growth in recent years and are likely to gain even more importance in the future. Their strong presence in the national electricity mix has created issues in many countries regarding the secure operation of the power system. In order to guarantee the stability of the system, several TSOs have resorted to wind energy curtailment, which represents a waste of clean energy and an economic loss. In order to analyze this issue, a model of the Italian power system was developed, a program able to simulate the electricity dispatching mechanism. The model was, then, used to evaluate possible solutions to reduce wind curtailment. In particular, a proposal for the construction of an HVDC line linking Southern and Northern Italy was studied.

  7. Lung cancer screening in the NELSON trial: balancing harms and benefits

    NARCIS (Netherlands)

    N. Horeweg (Nanda)

    2014-01-01

    markdownabstract__Abstract__ In this thesis, the harms and benefits of lung cancer screening using low-dose computed tomography were investigated. Data of the Dutch-Belgian NELSON trial were used to quantify its harms and benefits and develop strategies to improve the balance between them. If the

  8. 77 FR 1667 - Nelson S. Galgoul, Av. Edison Passess 909, Rio De Janeiro, R.J., Brazil 20531-070, Respondent...

    Science.gov (United States)

    2012-01-11

    ..., Rio De Janeiro, R.J., Brazil 20531-070, Respondent; Order Relating to Nelson S. Galgoul The Bureau of... entry of the Order, Nelson S. Galgoul, with a last known address of Av. Edison Passess 909, Rio De Janeiro, R.J., Brazil 20531-070, and when acting for or on his behalf, his representatives, assigns...

  9. Assessment of the Use of the Nelson Denny Reading Test.

    Science.gov (United States)

    Perkins, Dorothy

    1984-01-01

    The Nelson Denny Reading Test (NDRT) is probably the most widely used test of reading comprehension at the college level in the nation. However, reviews of the test, as well as recent reports of its failure to adequately measure gain or lack of gain of college students enrolled in reading improvement courses, do not support the popularity it has…

  10. Silenced but Not Silent: The Rhetorical Influence of Nelson Mandela.

    Science.gov (United States)

    Boyd, Susy

    In the epicenter of the political strife in South Africa is former African National Congress (ANC) leader Nelson Mandela. The ANC is considered to be the leading source of opposition to white rule in South Africa, and Mandela is one of the most revered and powerful figures to emerge from that organization. Incarcerated for over 25 years on charges…

  11. Hybrid simulation methods to perform grid integration studies for large scale offshore wind power connected through VSC-HVDC

    NARCIS (Netherlands)

    Meer, van der A.A.; Hendriks, R.L.; Gibescu, M.; Ferreira, J.A.; Kling, W.L.

    2011-01-01

    This paper deals with the inclusion of VSC-HVdc transmission schemes into stability-type simulations by hybrid methods. These methods allow selected parts of the network to be simulated in detail by including electro-magnetic behaviour of devices and network elements whereas the remainder of the

  12. Extension of Nelson's stochastic quantization to finite temperature using thermo field dynamics

    International Nuclear Information System (INIS)

    Kobayashi, K.; Yamanaka, Y.

    2011-01-01

    We present an extension of Nelson's stochastic quantum mechanics to finite temperature. Utilizing the formulation of Thermo Field Dynamics (TFD), we can show that Ito's stochastic equations for tilde and non-tilde particle positions reproduce the TFD-type Schroedinger equation which is equivalent to the Liouville-von Neumann equation. In our formalism, the drift terms in the Ito's stochastic equation have the temperature dependence and the thermal fluctuation is induced through the correlation of the non-tilde and tilde particles. We show that our formalism satisfies the position-momentum uncertainty relation at finite temperature. -- Highlights: → Utilizing TFD, we extend Nelson's stochastic method to finite temperature. → We introduce stochastic equations for tilde and non-tilde particles. → Our stochastic equations can reproduce the TFD-type Schroedinger equation. → Our formalism satisfies the uncertainly relation at finite temperature.

  13. Application of the Nelson model to four timelag fuel classes using Oklahoma field observations: Model evaluation and comparison with national Fire Danger Rating System algorithms

    Science.gov (United States)

    J. D. Carlson; Larry S. Bradshaw; Ralph M. Nelson; Randall R Bensch; Rafal Jabrzemski

    2007-01-01

    The application of a next-generation dead-fuel moisture model, the 'Nelson model', to four timelag fuel classes using an extensive 21-month dataset of dead-fuel moisture observations is described. Developed by Ralph Nelson in the 1990s, the Nelson model is a dead-fuel moisture model designed to take advantage of frequent automated weather observations....

  14. The search for a more human face for Nelson Mandela: An urgent task

    Directory of Open Access Journals (Sweden)

    Tinyiko Maluleke

    2015-08-01

    Full Text Available For many reasons, reflecting on the life of Nelson Mandela is a precarious exercise. If Mandela is a symbol of the resilience of the human spirit under trying conditions, he is also a symbol that is appropriated in various ways – helpful and unhelpful – by various people. This article explores some of the unhelpful ways in which the name and person of Nelson Mandela is invoked. In particular, the article looks at the hagiographical orientation of several reflections on Mandela, cautioning how some of these may have an effect less noble than originally intended. Accordingly, the article asks: How much can the symbol of Mandela bear? How much more can Mandela give? The logic and rationale of Mandela hagiography is explored. Following his death, there has been an explosion of interest in the life and symbol that is Nelson Mandela. Mandela literature, including multi-media, is on the rise. If the symbol of Mandela is in danger of being ‘cannibalised’, there is also a danger of relegating Mandela to an ahistorical mythical figure. The solution lies in at least two area, namely, the increment of alternative Mandela narratives and the introduction of more critical Mandela narratives. In this regard, Mandela’s own self-understanding as captured in his reflections about his life offer several clues which are explored in this article.

  15. First hvdc underwater transmission links mainland and Vancouver

    Energy Technology Data Exchange (ETDEWEB)

    1967-06-01

    Delicate and complex equipment for North America's first hvdc underwater transmission line is being installed. The power link will connect British Columbia Hydro and power authority's switchyards on the mainland near Ladner with the western terminus of the transmission scheme at Duncan on Vancouver Island, a distance of 42 miles. Nearly 19 miles of the transmission will be underwater, between Tsawwassen and Galiano Island, and between Parker and Saltspring Islands. The remaining distance will be spanned by a conventional aerial conductor. The submarine conductor cable will be approximately 3-1/2 inches in diameter and its copper core will be sheathed in lead and armored with a ring of steel wire. The cable, which is being manufactured in Calais, France, and coiled in a planned sequence aboard the cable laying vessel, Marcel Bayard, will be placed across the Gulf of Georgia in the spring of 1968.

  16. Cointegration analysis of the dynamic Nelson-Siegel model using the wild bootstrap

    NARCIS (Netherlands)

    Boswijk, H.P.

    2013-01-01

    The Dynamic Nelson-Siegel model describes the evolution over time of the term structure of interest rates in terms of three factors, characterising the level, slope and curvature of the yield curve. This article uses recently developed cointegration techniques for heteroskedastic time series to

  17. A method of Modelling and Simulating the Back-to-Back Modular Multilevel Converter HVDC Transmission System

    Science.gov (United States)

    Wang, Lei; Fan, Youping; Zhang, Dai; Ge, Mengxin; Zou, Xianbin; Li, Jingjiao

    2017-09-01

    This paper proposes a method to simulate a back-to-back modular multilevel converter (MMC) HVDC transmission system. In this paper we utilize an equivalent networks to simulate the dynamic power system. Moreover, to account for the performance of converter station, core components of model of the converter station gives a basic model of simulation. The proposed method is applied to an equivalent real power system.

  18. Rain and contamination tests on HVDC wall bushings with and without RTV coatings

    International Nuclear Information System (INIS)

    Schneider, H.M.; Hall, J.F.; Nellis, C.L.; Low, S.S.; Lorden, D.J.

    1991-01-01

    In this paper results of tests made to determine the ability of room temperature vulcanized (RTV) silicone rubber coatings to improve the performance of HVDC wall bushings are described. The behavior of uncoated full scale ± 500 kV wall bushings is first determined in wetting conditions consisting of nonuniform rain and fog with various amounts of pre-deposited surface contamination. Parameters affecting flashover performance, such as polarity, rain conductivity, and contamination severity are discussed. Results of nonuniform rain tests on an RTV coated wall bushing are reported

  19. Tunneling time distribution by means of Nelson's quantum mechanics and wave-particle duality

    International Nuclear Information System (INIS)

    Hara, Koh'ichiro; Ohba, Ichiro

    2003-01-01

    We calculate a tunneling time distribution by means of Nelson's quantum mechanics and investigate its statistical properties. The relationship between the average and deviation of tunneling time suggests the existence of 'wave-particle duality' in the tunneling phenomena

  20. ‘Magic Negro’, Saint or Comrade: Representations of Nelson Mandela in Film

    Directory of Open Access Journals (Sweden)

    Roger Bromley

    2014-11-01

    Full Text Available “In the late 1980s, Nelson Mandela stood alone against the apartheid state.” This comment taken from the DVD Box set cover of Nelson Mandela: From Freedom to History summarises the approach taken by many of the cinematic and televisual representations of Mandela. Linked with this is a statement by the CEO of Marriott which speaks of Mandela as “an individual who changed the arc of history through his or her singular contribution, not as a function of the era or the movement but because of what they did alone.” Together, these descriptions attempt to appropriate Mandela for a sanitised version of western individualism which sees him variously as a liberal icon, saintly hero, or the celebrity one-off “magic negro”, in Okwongo’s damning phrase taken from his magisterial valedictory piece “Mandela will never, ever be your minstrel” (Okwongo 2013. In the process, Mandela’s role in the anti-apartheid...

  1. Offshore grid transmission planning using approximated HVDC power flows

    Energy Technology Data Exchange (ETDEWEB)

    Torbaghan, Shahab Shariat; Rawn, Barry G.; Gibescu, Madeleine; Meijden, Mart van der [Delft Univ. of Technology (Netherlands). Dept. of Electrical Sustainable Energy

    2012-07-01

    In this paper we introduce an optimization framework which determines a socially optimum design of a HVDC offshore grid, under the assumption of a centralized network expansion planning scheme. This gives the optimum grid topology and interconnections capacity. In addition, the analytical solution to the optimization problem yields a market structure that expresses the relationship between the different regions' electricity prices and congestion charges associated with the interconnections. The optimization model sets the transmission capacities in a way that congestion shadow prices to be collected by the end of the economic lifetime of the project pay off the initial investment capital. We use this framework to study the impact of exercising different dispatching policies on the optimum design of the grid. The framework is applied to a multi-bus test system that functions under 8 different time periods. (orig.)

  2. Development of toroid-type HTS DC reactor series for HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kwangmin, E-mail: kwangmin81@gmail.com [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Lee, Sangjin [Uiduk University, Gyeongju 780-713 (Korea, Republic of); Oh, Yunsang [Vector Fields Korea Inc., Pohang 790-834 (Korea, Republic of); Park, Minwon; Yu, In-Keun [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of)

    2015-11-15

    Highlights: • The authors developed the 400 mH, 400 A class toroid-type HTS DC reactor system. • The target temperature, inductance and operating current are under 20 K at magnet, 400 mH and 400 A, respectively. All target performances of the HTS DC reactor were achieved. • The HTS DC reactor was conducted through the interconnection operation with a LCC type HVDC system. • Now, the authors are studying the 400 mH, 1500 A class toroid-type HTS DC reactor for the next phase HTS DC reactor. - Abstract: This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  3. Development of toroid-type HTS DC reactor series for HVDC system

    International Nuclear Information System (INIS)

    Kim, Kwangmin; Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho; Lee, Sangjin; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2015-01-01

    Highlights: • The authors developed the 400 mH, 400 A class toroid-type HTS DC reactor system. • The target temperature, inductance and operating current are under 20 K at magnet, 400 mH and 400 A, respectively. All target performances of the HTS DC reactor were achieved. • The HTS DC reactor was conducted through the interconnection operation with a LCC type HVDC system. • Now, the authors are studying the 400 mH, 1500 A class toroid-type HTS DC reactor for the next phase HTS DC reactor. - Abstract: This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  4. Relativism: Protagoras and Nelson Goodman

    Directory of Open Access Journals (Sweden)

    Esmaeil Saadati Khamseh

    2015-12-01

    Full Text Available Discussion of the many faces of relativism occupies a highly prominent place in the epistemological literature. Protagoras in ancient Greece and Nelson Goodman in the modern period are two most notable proponent of relativism. In the present article, I discuss and explain relativistic approaches of this two important relativist. I will first briefly define and review some faces of relativism. Then I will discuss and elaborate Protagorean or true-for-me relativism and Goodman’s radical relativism in turn. I will argue that there are crucial difficulties in Protagorean and radical relativism, and that these difficulties, as the realist philosophers insist, make these two faces of relativism be undefensible. No doubt, these two shapes of relativism have paved the way for anti-realism. In the end, it will appear that Goodman’s radical relativism and so the theory of worldmaking, like Protagorean relativism, suffers from a fatal flaw: the flaw of self-refuting.

  5. Fulfilment of Grid Code Obligations by Large Offshore Wind Farms Clusters Connected via HVDC Corridors

    OpenAIRE

    Attya, A.B.; Anaya-Lara, Olimpo; Ledesma, P.; Svendsen, Harald Georg

    2016-01-01

    - The foreseen high penetration levels of wind power will force the systems operators to apply restrictive constraints on wind power plants. The ability of offshore wind clusters, which are connected via HVDC, to fulfill the grid codes, especially those related to voltage stability is investigated. This came in the frame of a project to develop an integrated and practical tool to design offshore wind clusters (EERA-DTOC). The applied case studies examine the system stability during and aft...

  6. Cost estimation of HVDC transmission system of Bangka's NPP candidates

    Science.gov (United States)

    Liun, Edwaren; Suparman

    2014-09-01

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  7. Celebrating the Hero in All of Us: An Interview with Kadir Nelson

    Science.gov (United States)

    Sableski, Mary-Kate; Arnold, Jackie Marshall; Adomat, Donna Sayers

    2015-01-01

    Books provide an opportunity through which children can learn what it means to be in the world and to respond flexibly and creatively to a diverse range of situations. Author/illustrator Kadir Nelson creates books that provide these opportunities for readers of all ages. A dominant theme in current conversations surrounding children's literature…

  8. Investigating the impact of unanticipated market and construction delays on the development of a meshed HVDC grid using dynamic transmission planning

    NARCIS (Netherlands)

    Shariat Torbaghan, S.; Gibescu, M.; Rawn, B.G.; Müller, H.; Roggenkamp, M.; vd Meijden, M.A.M.M.

    2015-01-01

    This study presents a market-based dynamic transmission planning framework for the construction of a meshed offshore voltage source converter-high voltage direct current (VSC-HVDC) grid. Such a grid is foreseen for integrating offshore wind and electricity trade functions among the North Sea

  9. Characterization of mercury and its risk in Nelson's, Saltmarsh, and Seaside Sparrows.

    Directory of Open Access Journals (Sweden)

    Virginia L Winder

    Full Text Available BACKGROUND: Nelson's, Saltmarsh, and Seaside Sparrows (Ammodramus nelsoni, A. caudacutus, and A. maritimus, respectively depend on marsh and wetland habitats--ecosystems in which mercury (Hg bioavailability is notoriously high. The purpose of the present study was to address the potential impact of Hg on these species using first primary and breast feathers as non-destructive biomonitoring tools. METHODS AND PRINCIPAL FINDINGS: Feathers were sampled from wintering sparrows in North Carolina salt marshes (2006-2010. Feather Hg data were used in three risk analysis components (1 Threshold Component--examined feather Hg with regard to published negative effects thresholds; (2 Hg Dynamics Component--examined Hg in sparrows captured multiple times; and (3 Capture Frequency and Survival Component--tested for links between Hg and return frequency and survival. Threshold Component analyses indicated that Hg concentrations in 42-77% of sampled individuals (breast feather n = 879; first primary feather n = 663 were within the range associated with decreased reproduction in other avian species. Hg Dynamics Component analyses demonstrated that Hg increased between first and second captures for Nelson's (n = 9 and Seaside Sparrows (n = 23. Capture Frequency and Survival Component analyses detected a negative relationship between Hg and capture frequency in Nelson's Sparrows (n = 315. However, MARK models detected no effect of Hg on apparent survival in any species. CONCLUSION AND SIGNIFICANCE: This study indicates that current Hg exposure places a considerable proportion of each population at risk. In particular, 52% of all sampled Saltmarsh Sparrows exhibited first primary feather Hg concentrations exceeding those associated with a >60% reduction in reproductive success in other species. This study reports evidence for net annual bioaccumulation, indicating an increased risk in older individuals. These data can be used to inform future population

  10. Characterization of mercury and its risk in Nelson's, Saltmarsh, and Seaside Sparrows.

    Science.gov (United States)

    Winder, Virginia L

    2012-01-01

    Nelson's, Saltmarsh, and Seaside Sparrows (Ammodramus nelsoni, A. caudacutus, and A. maritimus, respectively) depend on marsh and wetland habitats--ecosystems in which mercury (Hg) bioavailability is notoriously high. The purpose of the present study was to address the potential impact of Hg on these species using first primary and breast feathers as non-destructive biomonitoring tools. Feathers were sampled from wintering sparrows in North Carolina salt marshes (2006-2010). Feather Hg data were used in three risk analysis components (1) Threshold Component--examined feather Hg with regard to published negative effects thresholds; (2) Hg Dynamics Component--examined Hg in sparrows captured multiple times; and (3) Capture Frequency and Survival Component--tested for links between Hg and return frequency and survival. Threshold Component analyses indicated that Hg concentrations in 42-77% of sampled individuals (breast feather n = 879; first primary feather n = 663) were within the range associated with decreased reproduction in other avian species. Hg Dynamics Component analyses demonstrated that Hg increased between first and second captures for Nelson's (n = 9) and Seaside Sparrows (n = 23). Capture Frequency and Survival Component analyses detected a negative relationship between Hg and capture frequency in Nelson's Sparrows (n = 315). However, MARK models detected no effect of Hg on apparent survival in any species. This study indicates that current Hg exposure places a considerable proportion of each population at risk. In particular, 52% of all sampled Saltmarsh Sparrows exhibited first primary feather Hg concentrations exceeding those associated with a >60% reduction in reproductive success in other species. This study reports evidence for net annual bioaccumulation, indicating an increased risk in older individuals. These data can be used to inform future population assessments and management for these species.

  11. The judgement of simultaneous commutation failure in HVDC about hierarchical connection to AC grid

    Science.gov (United States)

    Li, Ming; Song, Xinli; Huang, Daoshan; Liu, Wenzhuo; Zhao, Shutao; Ye, Xiaohui; Meng, Hang

    2017-09-01

    The hierarchical connection to AC grid at inverter sides in UHVDC has been take in several projects. This paper introduced the frame of the connection mode in hierarchical access system and compared it with the traditional one at the case of HVDC-Cigre. Then the criterion of commutation failure according to the same valves current was deduced. In order to verify the accuracy of the criterion, this paper used PSD-BPA (Bonneville Power Administration) to simulate the setting voltage drop in the East China power grid and certified the correctness of the formula.

  12. A comparison of the value of MRI and CT in patients with Nelson syndrome

    International Nuclear Information System (INIS)

    Kersjes, W.; Allmendinger, S.; Christ, F.; Stiebler, H.; Bockisch, A.; Klingmueller, D.

    1992-01-01

    The hypophyses of 13 patients with Nelson syndrome following bilateral adrenalectomy were examined by MRI and CT. Diffuse enlargement of the hypophysis was demonstrated in 8 patients by CT and in 9 by MRI. Compared with CT, MRI provides better demonstration of tumour development, such as abnormal convexity of the cranial margin of the hypophysis (MRI 4/13, CT 1/13), displacement of the infundibulum (MRI 4/13, CT 0/13) or optic chiasm (MRI 2/13, CT 0/13). MRI also provides diagnostically important differentiation between scar tissue and recurrence of tumour following hypophysectomy (MRI 1/3, CT 0/3) and more accurate demonstration of infiltration of the cavernous sinus (MRI 4/13, CT 2/13). CT is superior only in showing the floor of the sella. MRI is the method of choice for imaging in cases of Nelson syndrome. (orig.) [de

  13. The generalized Fenyes-Nelson model for free scalar field theory

    International Nuclear Information System (INIS)

    Davidson, M.

    1980-01-01

    The generalized Fenyes-Nelson model of quantum mechanics is applied to the free scalar field. The resulting Markov field is equivalent to the Euclidean Markov field with the times scaled by a common factor which depends on the diffusion parameter. This result is consistent with Guerra's earlier work on stochastic quantization of scalar fields. It suggests a deep connection between Euclidean field theory and the stochastic interpretation of quantum mechanics. The question of Lorentz covariance is also discussed. (orig.)

  14. Modelling of HVDC wall bushing flashover in nonuniform rain

    International Nuclear Information System (INIS)

    Rizk, F.A.M.; Kamel, S.I.

    1991-01-01

    This paper presents the first mathematical model to provide necessary and sufficient conditions for flashover of an HVDC wall bushing under nonuniform rain. The suggested mechanism is initiated by streamer bridging of the dry zone enhanced by nonuniform voltage distribution along the bushing and within the dry zone. Fast voltage collapse across the dry zone die to energy stored in the bushing stray capacitance to ground leads to impulsive stressing of the wet part of the bushing. The nonuniform distribution of the impulse stress and the process of streamer bridging, fast voltage collapse as well as subsequent recharging of the bushing capacitances can lead to continued discharge propagation and flashover of the complete bushing. The findings of the model have been satisfactorily compared with previous experiments and field observations and can, for the first time, account for the following aspects of the flashover mechanism: critical dry zone length, polarity effect, specific leakage path, wet layer conductance per unit leakage length as well as the DC system voltage

  15. Integral Plus Resonant Sliding Mode Direct Power Control for VSC-HVDC Systems under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Weipeng Yang

    2017-10-01

    Full Text Available An integral plus resonant sliding mode direct power control (IRSMC DPC strategy for voltage source converter high voltage direct current (VSC-HVDC systems under unbalanced grid voltage conditions is proposed in this paper. Through detailed instantaneous power flow analysis, a generalized power compensation method, by which the ratio between the amplitude of active and reactive power ripples can be controlled continuously, is obtained. This enables the system to provide flexible power control, so that the desired performance of the system on both the ac and dc sides can be attained under different operating conditions. When the grid voltage is unbalanced, one or both of the active and reactive power terms contain ripples, oscillating at twice the grid frequency, to obtain non-distorted ac current. A power controller consisting of the proportional, integral and resonant control laws is designed using the sliding mode control approach, to achieve accurate power control objective. Simulation studies on a two-terminal VSC-HVDC system using MATLAB/SIMULINK (R2013b, Mathworks, Natick, MA, USA are conducted to verify the effectiveness of the IRSMC DPC strategy. The results show that this strategy ensures satisfactory performance of the system over a wide range of operating conditions.

  16. A rotated Dynamic Nelson-Siegel model with macro-financial applications

    OpenAIRE

    Nyholm, Ken

    2015-01-01

    A factor rotation scheme is applied to the well-known Dynamic Nelson-Siegel model facilitating direct parametrization of the short rate process. The model-implied term structure of term premia is derived in closed-form, and macroeconomic variables are included in a Taylor-rule- type fashion. Four empirical experiments are performed on US data covering the period from 1990 to 2014. It is found that macroeconomic variables impact the evolution of the short rate until 2002, after which their eff...

  17. The pure phases, the irreducible quantum fields, and dynamical symmetry breaking in Symanzik--Nelson positive quantum field theories

    International Nuclear Information System (INIS)

    Frohlich, J.

    1976-01-01

    We prove that a Symanzik--Nelson positive quantum field theory, i.e., a quantum field theory derived from a Euclidean field theory, has a unique decomposition into pure phases which preserves Symanzik--Nelson positivity and Poincare covariance. We derive useful sufficient conditions for the breakdown of an internal symmetry of such a theory in its pure phases, for the self-adjointness and nontrivially (in the sense of Borchers classes) of its quantum fields, and the existence of time-ordered and retarded products. All these general results are then applied to the P (phi) 2 and the phi 3 4 quantum field models

  18. Cooperative control scheme for an HVDC system connected to an isolated BWR nuclear power plant

    International Nuclear Information System (INIS)

    Sakurai, T.; Goto, K.; Kawai, T.; Matori, I.; Nakao, T.; Watanabe, A.

    1983-01-01

    This paper describes a cooperative control system to achieve stable operation of an isolated BWR nuclear plant linked to an HVDC system. In the proposed control system, under normal conditions the power plant is controlled according to the generating power reference and the generator frequency deviation is adjusted by converter power control. Such frequency control is also effective in the case of AC-DC system faults. In addition to the frequency control, an overload control is provided with the HVDC system, where the DC transmission power in the sound poles is increased due to a fault detection signal from the faulty pole. Effects of the above mentioned control systems were studied using digital dynamic programs. The sets of simulation results confirmed that in the case of a DC single pole fault, the plant is able to continue operation without any use of the turbine speed control units even for a restarting failure in the faulty pole. In case of a DC two pole fault, the plant is able to continue operation, being assisted by turbine speed control units when restarting in the faulty poles succeeds. In case of an AC three-line to ground fault near the AC terminal of the converter at the sending or receiving end, the system is able to continue stable operation, being supplemented by the turbine control unit when the faulty section of the AC system is isolated by a main or back-up relaying system

  19. Social Justice and Human Rights in Education Policy Discourse: Assessing Nelson Mandela's Legacy

    Science.gov (United States)

    Gebremedhin, Abrehet; Joshi, Devin

    2016-01-01

    Twenty years after South Africa's democratisation, Nelson Mandela's passing has prompted scholars to examine his legacy in various domains. Here we take a look at his legacy in education discourse. Tracing Mandela's thoughts and pronouncements on education we find two major emphases: a view of education as a practical means to economic…

  20. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    Energy Technology Data Exchange (ETDEWEB)

    Liun, Edwaren, E-mail: edwaren@batan.go.id; Suparman, E-mail: edwaren@batan.go.id [Centre for Nuclear Energy Development, National Nuclear Energy Agency of Indonesia (Indonesia)

    2014-09-30

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  1. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    International Nuclear Information System (INIS)

    Liun, Edwaren; Suparman

    2014-01-01

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different

  2. Failure Analysis of Main Flame Deflector Nelson Studs

    Science.gov (United States)

    Long, Victoria

    2009-01-01

    NASA Structures engineers submitted two Nelson refractory studs from the main flame deflector at Launch Complex (LC) 39 A for analysis when they were observed to be missing a significant amount of material after launch. The damaged stud and an unused comparative stud were analyzed by macroscopic and microscopic examination along with metallographic evaluation of the microstructure. The stud lost material due to a combination of erosion and corrosion. Plain carbon steel readily forms an oxide layer in the coastal launch environment at Kennedy Space Center. The blast during a launch removes this brittle oxide layer, which then forms again post-launch, thereby further removing material. No indications of melting were observed.

  3. A hermeneutical reading of Penrose and Nelson and Winter-Tracing origins of a misunderstanding?

    Directory of Open Access Journals (Sweden)

    Dr. Oliver Krone

    2010-05-01

    Full Text Available This paper aims to understand based on a hermeutical reading of Penrose (1959 and Nelson and Winter (1982 what knowledge is and where it is stored in the respective authors. Furthermore, the author wants to learn whether the subsumtion of Knowledge Integration to Knowledge Management, as it can be often in the literature, has any foundation when coming from these authors. Reason for this overall analysis is the widely held view in the discipline of Knowledge Management that these authors are forefathers for it. Based on an interpretative, qualitative approach the author examines the way in which knowledge is held and created within organisations in the main work of this pair of author. The author comes to the conclusion that the discipline of Knowledge Management has seemingly overemphasised certain elements in the work of Penrose and Nelson and Winter, while neglecting the key aspect that for both author(s the act of Knowledge Integration is much rather described in these works.

  4. Relevance of HVDC for electrical power supply; Bedeutung der HGUein der Energieversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Gambach, Herbert; Dorn, Joerg [Siemens AG, Erlangen (Germany). Power Transmission Solutions

    2012-07-01

    The finite availability of fossil energy, the turning away of many countries from nuclear power generation and the need for a limitation of CO{sub 2} emissions influence the future generation and transmission of electrical power in a significant way. In the long term these requirements can be met only by renewable energy sources, for instance solar power and wind. Another aspect is that power generation facilities are in many cases far-off from the load centers. This enforces reliable transmission systems with low losses over long distances. The high voltage direct current (HVDC) transmission complies with these demands in a beneficial way. This paper gives a short overview of the state-of-the-art and describes current developments. (orig.)

  5. The Applicability of Traditional Protection Methods to Lines Emanating from VSC-HVDC Interconnectors and a Novel Protection Principle

    Directory of Open Access Journals (Sweden)

    Shimin Xue

    2016-05-01

    Full Text Available Voltage source converter (VSC-based high voltage direct current (VSC-HVDC interconnectors can realize accurate and fast control of power transmission among AC networks, and provide emergency power support for AC networks. VSC-HVDC interconnectors bring exclusive fault characteristics to AC networks, thus influencing the performance of traditional protections. Since fault characteristics are related to the control schemes of interconnectors, a fault ride-through (FRT strategy which is applicable to the interconnector operating characteristic of working in four quadrants and capable of eliminating negative-sequence currents under unbalanced fault conditions is proposed first. Then, the additional terms of measured impedances of distance relays caused by fault resistances are derived using a symmetrical component method. Theoretical analysis shows the output currents of interconnectors are controllable after faults, which may cause malfunctions in distance protections installed on lines emanating from interconnectors under the effect of fault resistances. Pilot protection is also inapplicable to lines emanating from interconnectors. Furthermore, a novel pilot protection principle based on the ratio between phase currents and the ratio between negative-sequence currents flowing through both sides is proposed for lines emanating from the interconnectors whose control scheme aims at eliminating negative-sequence currents. The validity of theoretical analysis and the protection principle is verified by PSCAD/EMTDC simulations.

  6. Study on electrochemical corrosion mechanism of steel foot of insulators for HVDC lines

    Science.gov (United States)

    Zheng, Weihua; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    The main content of this paper is the mechanism of electrochemical corrosion of insulator steel foot in HVDC transmission line, and summarizes five commonly used artificial electrochemical corrosion accelerated test methods in the world. Various methods are analyzed and compared, and the simulation test of electrochemical corrosion of insulator steel feet is carried out by water jet method. The experimental results show that the experimental environment simulated by water jet method is close to the real environment. And the three suspension modes of insulators in the actual operation, the most serious corrosion of the V type suspension hardware, followed by the tension string suspension, and the linear string corrosion rate is the slowest.

  7. Nelson Mandela's defence: A psychological capital documentary analysis

    Directory of Open Access Journals (Sweden)

    Rene van Wyk

    2014-11-01

    Full Text Available This qualitative documentary analysis examines Nelson Mandela�s defence statement at the Rivonia Trial, Pretoria Supreme Court, on 20 April 1964. The defence document is analysed through the psychological capital lens, depicting themes that support the constructs of hope, efficacy, resilience and optimism. Psychological capital characteristics played a major role in the initial non-violent policies of negotiation. The inevitable establishment of Umkhonto we Sizwe followed, as a result of the increased restrictions and unwillingness of government to negotiate and collaborate. Mandela showed a determined spirit to unite the country. The discussion gives insight into Mandela�s authentic psychological capital leadership under difficult political and personal circumstances. Some implications are indicated in adopting Mandela�s psychological characteristics for personal reform.

  8. Dynamic Reactive Power Control in Offshore HVDC Connected Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain

    2016-01-01

    This paper presents a coordinated reactive power control for a HVDC connected cluster of offshore wind power plants (WPPs). The reactive power reference for the WPP cluster is estimated by an optimization algorithm aiming at minimum active power losses in the offshore AC Grid. For each optimal......, such as wind turbine (WT) terminal, collector cable, and export cable, on the dynamic voltage profile of the offshore grid is investigated. Furthermore, the dynamic reactive power contribution from WTs from different WPPs of the cluster for such faults has also been studied....... reactive power set point, the OWPP cluster controller generates reactive power references for each WPP which further sends the AC voltage/ reactive power references to the associated WTs based on their available reactive power margin. The impact of faults at different locations in the offshore grid...

  9. Uniform product formulae with application to the Feynman-Nelson integral for open systems

    International Nuclear Information System (INIS)

    Exner, P.; Kolerov, G.I.

    1982-01-01

    The product formula for perturbations of propagators by Faris is generalized: we show that one can use arbitrary partitions of a given interval and perform the limit uniformly with respect to the partition norm. The results are applied to express solutions of the Schroedinger equation, in particular for some complex and time-dependent potentials, by means of Nelson-type path integrals. (orig.)

  10. Comparison of PI and PR current controllers applied on two-level VSC-HVDC transmission system

    DEFF Research Database (Denmark)

    Manoloiu, A.; Pereria, H.A.; Teodorescu, Remus

    2015-01-01

    This paper analyzes differences between αβ and dq reference frames regarding the control of two-level VSC-HVDC current loop and dc-link voltage outer loop. In the first part, voltage feedforward effect is considered with PI and PR controllers. In the second part, the feedforward effect is removed...... and the PR gains are tuned to keep the dynamic performance. Also, the power feedforward is removed and the outer loop PI controller is tuned in order to maintain the system dynamic performance. The paper is completed with simulation results, which highlight the advantages of using PR controller....

  11. PERBANDINGAN METODE SOMOGYI-NELSON DAN ANTHRONE-SULFAT PADA PENETAPAN KADAR GULA PEREDUKSI DALAM UMBI CILEMBU (Ipomea batatas L.

    Directory of Open Access Journals (Sweden)

    Hasanul Kiyan Al-kayyis

    2016-11-01

    Full Text Available Sweet potato cultivar Cilembu, kind of ‘rancing’ from Cilembu Village, Sumedang, West Java has really sweet taste due to the high content of reducing sugar. The amount of reducing sugar needs to be proven scientifically. The study aimed to compare Somogyi-Nelson method and Anthrone-Sulfate method in order to determine reducing sugar level in Cilembu sweet potato. Cilembu sweet potato must be stored in freezer at 15°C for 2 weeks before used as the sample. Analytical method validation was performed for the two methods. The determination results between two methods were compared. The amount of reduction sugar (glucose from Cilembu sweet potato determined by Somogyi-Nelson method was 3.42%, the value of %recovery was 99.8%, LOD = 0.00167 (mg/mL, LOQ = 0.00557 (mg/mL, and value of RSD was 3.7%. While the average amount of reduction sugar determined by Anthrone-Sulfate method was 14.9%, the value of %recovery was 74.7%, LOD = 0.0198 (mg/mL, LOQ = 0.066 (mg/mL, and value of RSD = 8.6%. The Somogyi-Nelson method was more recommended for the analysis of the reducing sugar in Cilembu sweet potato compared with Anthrone-Sulfate method.

  12. Horn river basin (shale gas): A primer of challenges and solutions to development

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, Colin; Williams-Kovacs, Jesse; Jackson, Rob

    2010-09-15

    Unconventional sources of fossil fuels The Horn River Basin, a massive unconventional shale gas resource, covers an area of approximately 3 million acres in North East British Columbia stretching from Fort Nelson to the Northwest Territories, will need to be significant part of the Canadian energy mix. Yet, this play is still in the early stages of development despite significant economic and supply potential. This paper will outline the many technical and economic challenges, as well as the possible solutions and strategies being employed to reduce risk and make the play a commercial success.

  13. Passageless Comprehension on the "Nelson-Denny Reading Test": Well above Chance for University Students

    Science.gov (United States)

    Coleman, Chris; Lindstrom, Jennifer; Nelson, Jason; Lindstrom, William; Gregg, K. Noel

    2010-01-01

    The comprehension section of the "Nelson-Denny Reading Test" (NDRT) is widely used to assess the reading comprehension skills of adolescents and adults in the United States. In this study, the authors explored the content validity of the NDRT Comprehension Test (Forms G and H) by asking university students (with and without at-risk…

  14. Nelson's stochastic quantization of free linearized gravitational field and its Markovian structure

    International Nuclear Information System (INIS)

    Lim, S.C.

    1983-05-01

    It is shown that by applying Nelson's stochastic quantization scheme to free linearized gravitational field tensor one can associate with the resulting stochastic system a stochastic tensor field which coincides with the ''space'' part of the Riemannian tensor in Euclidean space-time. However, such a stochastic field fails to satisfy the Markov property. Instead, it satisfies the reflection positivity. The Markovian structure of the stochastic fields associated with the electromagnetic field is also discussed. (author)

  15. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    Science.gov (United States)

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with

  16. Comments on the note by L.S. Nelson: ''unusually high (oxidizer/Pu) ratios in the macro-residues from plutonium droplet combustion''

    International Nuclear Information System (INIS)

    Allen, M.D.; Morgan, L.G.

    1982-01-01

    An alternative explanation for unusually high ratios of oxidizers/plutonium in the residues from plutonium droplet combustion is offered in response to a note by L.S. Nelson. Two additional experiments are suggested that would be helpful in clarifying the high oxidizer/Pu ratios. The first would be to measure the true surface area for a spherule after its explosion. The second is an experiment analogous to a gas analysis experiment. The conclusion is put forth that adsorbed gases are the most likely cause of the high O/M ratios described by Nelson

  17. Adaptation of the Nelson-Somogyi reducing-sugar assay to a microassay using microtiter plates.

    Science.gov (United States)

    Green, F; Clausen, C A; Highley, T L

    1989-11-01

    The Nelson-Somogyi assay for reducing sugars was adapted to microtiter plates. The primary advantages of this modified assay are (i) smaller sample and reagent volumes, (ii) elimination of boiling and filtration steps, (iii) automated measurement with a dual-wavelength scanning TLC densitometer, (iv) increased range and reproducibility, and (v) automated colorimetric readings by reflectance rather than absorbance.

  18. Control and Protection of Wind Power Plants with VSC-HVDC Connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay

    oscillations, and hence, lower dc voltage overshoots in the VSC-HVDC system. On the protection side, the coordination of over-current relays has been analysed in the new environment. A simple yet reliable scheme utilizing the well-known over-current relay characteristics has been presented for the detection...... grid frequency from the onshore grid frequency. Three different methods have been evaluated here for relaying the onshore grid frequency to the offshore grid, such that the wind power plant can participate in the grid frequency control. One of the schemes does not involve communication, while the other...... of faults and the determination of faulted feeder in the offshore grid. It is demonstrated that the communication capability of modern relays can help avoid the potential cases of over-reach. The test system is modelled for real time simulation in RSCAD/RTDS platform, such that the physical relays could...

  19. Charging large capacitor banks for fusion research using HVDC conversion equipment

    International Nuclear Information System (INIS)

    Brown, D.R.; Bird, W.L.; Huang, Y.C.; Tolk, K.

    1984-01-01

    Fundamental considerations in the choice of a continuous duty capacitor bank charging system using HVDC conversion equipment are presented. Large systems of the type used in fusion related research pose significant system related problems if they are to be supplied from a conventional power grid. Schemes for conditioning the required power in order to overcome such problems are presented and evaluated. A resonant charging system is examined in detail and shown to be superior in a number of ways to constant current charging. Results of digital computer simulation studies are used to demonstrate the feasibility of the system. It is shown that the resonant charging system reduces rectifier capacity, simplifies control and reduces reactive power fluctuations. Sequential bank charging and use of a motor-generator set are presented as techniques for compensation of real power fluctuations and a comparison on the basis of initial cost is presented

  20. Integration of a finite element generator model into a simulated HVDC connected system

    Energy Technology Data Exchange (ETDEWEB)

    Preston, T W; Sturgess, J P [GEC Alsthom Engineering Research Center, Stafford (United Kingdom)

    1994-12-31

    Within most system analysis programs generators and motors are represented by an equivalent circuit model either a 2-axis model for both stators and rotor or a three-phase model of the stator and a two-axis model of the rotor. This may be adequate under certain operating conditions such as steady-state or some symmetrical faults but for inverter-fed motors or generators feeding into a rectified load a more rigorous model of the machine is required. This paper describes the theory and development of such a model, its integration with the power electronics and application to 6-pulse and 12-pulse converters, the latter being appropriate in systems similar to HVDC unit connection. (author) 5 refs., 16 figs.

  1. Finite element modelling of ionized field quantities around a monopolar HVDC transmission line

    International Nuclear Information System (INIS)

    Jaiswal, Vinay; Thomas, M Joy

    2003-01-01

    In this paper, the Poisson's equation describing the ionized field around an HVDC line is solved using an improved finite element based technique. First order isoparametric quadrilateral elements, together with a modified updating criterion for the space charge distribution, are implemented in the iterative procedure. A novel technique is presented for mesh generation in the presence of space charges. Electric field lines and equipotential lines have been computed using the proposed technique. Total corona current at different applied voltages above corona onset voltage, electric field at the ground plane with and without the presence of space charges and current density at the ground plane have also been computed. The results are in agreement with the experimental values available in the published literature

  2. An adaptive neuro fuzzy inference system controlled space cector pulse width modulation based HVDC light transmission system under AC fault conditions

    Science.gov (United States)

    Ajay Kumar, M.; Srikanth, N. V.

    2014-03-01

    In HVDC Light transmission systems, converter control is one of the major fields of present day research works. In this paper, fuzzy logic controller is utilized for controlling both the converters of the space vector pulse width modulation (SVPWM) based HVDC Light transmission systems. Due to its complexity in the rule base formation, an intelligent controller known as adaptive neuro fuzzy inference system (ANFIS) controller is also introduced in this paper. The proposed ANFIS controller changes the PI gains automatically for different operating conditions. A hybrid learning method which combines and exploits the best features of both the back propagation algorithm and least square estimation method is used to train the 5-layer ANFIS controller. The performance of the proposed ANFIS controller is compared and validated with the fuzzy logic controller and also with the fixed gain conventional PI controller. The simulations are carried out in the MATLAB/SIMULINK environment. The results reveal that the proposed ANFIS controller is reducing power fluctuations at both the converters. It also improves the dynamic performance of the test power system effectively when tested for various ac fault conditions.

  3. Construção de curva de juros de debêntures no mercado brasileiro utilizando a parametrização de Nelson-Siegel Construcción de curva de tipo de interés de bonos en el mercado brasileño mediante la parametrización de Nelson-Siegel Constructing the yield curve for Brazilian debentures using Nelson-Siegel parameterization

    Directory of Open Access Journals (Sweden)

    Vinícius Gomes Araújo

    2013-03-01

    Full Text Available O objetivo nesse trabalho é a construção da Estrutura a Termo de Taxa de Juros (ETTJ das debêntures que se encontram disponíveis no mercado brasileiro, usando o modelo Nelson-Siegel (1987. As curvas de juros são divididas de acordo com o tipo de indexador e com a classificação de risco atribuída às debêntures. Por fim, foi possível mensurar o spread que existe entre o mercado de títulos privados (debêntures e os títulos públicos.El objetivo en este trabajo es determinar la estructura temporal de tipos de interés (ETTI de los bonos que se encuentran disponibles en el mercado brasileño, por medio del uso del modelo de Nelson-Siegel (1987. Las curvas de rendimientos fueron divididas de acuerdo con el tipo de índice y con la clasificación de riesgo atribuida a los bonos. Fue posible medir el spread entre el mercado de bonos corporativos (debentures y el mercado de los títulos del Estado.The aim of this work is to establish a term structure of interest rates for corporate bonds in the Brazilian market, using the Nelson-Siegel model (1987. The yield curves were divided by the type of index and the rating level. It was possible to measure the spread between the corporate bonds market and the government bonds market.

  4. DC Voltage Droop Control Structures and its Impact on the Interaction Modes in Interconnected AC-HVDC Systems

    DEFF Research Database (Denmark)

    Thams, Florian; Chatzivasileiadis, Spyros; Eriksson, Robert

    2017-01-01

    Different dc voltage droop control structures for future multi-terminal HVDC systems have been proposed in literature. This paper contributes to the evaluation of those structures by an analysis of their impact on the coupling of the interconnected subsystems. In particular, the modes...... of the systems are classified in different subsets according to the participation of the various subsystems. Those subsets are then evaluated qualitatively and quantitatively indicating which impact the choice of the droop control structure has on the degree of coupling between the connected ac and dc systems...

  5. A personal experience in the presence of a man who transformed a nation and changed the world: Nelson Mandela.

    Science.gov (United States)

    Brown, Geraldine

    2014-01-01

    At this time in history, I consider myself very privileged to have spent some three hours in the presence of President Nelson Mandela as a Howard University faculty member in the late 1990s. Then, President of Howard University, H. Patrick Swygert bestowed upon President Nelson Mandela, Esquire an Honorary Doctorate of Human Letters. I can only equate this experience to my four mile walk up the Bedaling Wall (Great Wall) in China (a magnificent ancient wonder of the world), and trying to relate this event to something only fortunate souls have had the chance to enjoy. I also treasure the once in a lifetime visit to the Republic of South Africa in 1998 when the Association of Black Nursing Faculty, Inc., Chi Eta Phi Nursing Sorority, Inc., and the Department of Nursing (University of Botswana) sponsored the trip as an attempt to establish partnerships, share common interests and discussion in how to meet health needs of emerging majority and disadvantaged populations in the world, including mainly, the continent of Africa, in the 21st century. This short memoir can only piggy-back the massive coverage in the media that began almost instantly as a long anticipated event (death of Nelson Mandela), but startled upon its occurrence.

  6. Representation theory of Lie-admissible enveloping algebras on operator algebras: an extension of a theorem by Nelson

    International Nuclear Information System (INIS)

    Ghikas, D.K.P.; Ktorides, C.N.; Papaloukas, L.

    1980-01-01

    This mathematical note is motivated by an assessment concerning our current understanding of the role of Lie-admissible symmetries in connection with quantum structures. We identify the problem of representations of the universal enveloping (lambda, μ)-mutation algebra of a given Lie algebra on a suitable algebra of operators, as constituting a fundamental first step for improving the situation. We acknowledge a number of difficulties which are peculiar to the adopted nonassociative product for the operator algebra. In view of these difficulties, we are presently content in establishing the generalization, to the Lie-admissible case, of a certain theorem by Nelson. This theorem has been very instrumental in Nelson's treatment concerning the Lie symmetry content of quantum structures. It is hoped that a similar situation will eventually prevail for the Lie-admissible case. We offer a number of relevant suggestions

  7. "Passageless" Administration of the Nelson-Denny Reading Comprehension Test: Associations with IQ and Reading Skills

    Science.gov (United States)

    Ready, Rebecca E.; Chaudhry, Maheen F.; Schatz, Kelly C.; Strazzullo, Sarah

    2013-01-01

    There are few tests that assess reading comprehension in adults, but these tests are needed for a comprehensive assessment of reading disorders (RD). "The Nelson-Denny Reading Test" (NDRT) has a long-passage reading comprehension component that can be used with adolescents and adults. A problem with the NDRT is that reading comprehension…

  8. Fault Ride Through Enhancement of VSC‐HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Jensen, Kim Høj

    2018-01-01

    the model of a VSC‐HVDC‐connected offshore wind power plant (WPP) with an external grid. It proposes a feedforward DC voltage control based FRT technique to control the AC voltage at the WPP collector network during grid‐side faults. Time‐domain simulations have been used to verify the efficacy......Voltage source converter‐high voltage direct current (VSC‐HVDC) connections have become a new trend for long‐distance offshore wind power transmission. In order to facilitate the derivation of the feedforward DC voltage control based fault ride through (FRT) technique, this chapter describes...... of the proposed feedforward DC voltage control based FRT technique for VSC‐HVDC‐connected WPPs. Time‐domain simulation results shows that the proposed FRT scheme can successfully enable VSC‐HVDC‐connected WPPs to ride through balanced and unbalanced faults in host power systems, as well as faults in the WPP...

  9. On the Reconciliation of the Extended Nelson-Siegel and the Extended Vasicek Models (with a View Towards Swap and Swaption Valuation)

    DEFF Research Database (Denmark)

    Jørgensen, Peter Løchte

    Extended Nelson-Siegel models are widely used by e.g. practitioners and central banks to estimate current term structures of riskless zero-coupon interest rates, whereas other models such as the extended Vasicek model (a.k.a. the Hull-White model) are popular for pricing interest rate derivatives....... This paper establishes theoretical consistency between these two types of models by showing how to specify the extended Vasicek model such that its implied initial term structure curve precisely matches a given extended Nelson-Siegel specification. That is, we show how to reconcile the two classes of models...

  10. Shaping Influences on the Leadership of Genghis Khan, George Washington, and Nelson Mandela: Applications for Educators

    Science.gov (United States)

    Bongila, Jean-Pierre

    2011-01-01

    Using a prosopographical methodology this study examines common leadership influences that might have existed among Genghis Khan, George Washington, and Nelson Mandela. Shoup (2005) suggests that the following seven influences have contributed to nurturing the leadership of 12 renowned individuals: involved parents, happy childhood, formal,…

  11. Modeling of Chromium (III) Removal from Heavy Metals Mixture Solutions in Continuous Flow Systems: A Comparative Study between BDST and Yoon -Nelson Models

    International Nuclear Information System (INIS)

    Ahmed, A.Z.

    2011-01-01

    The aim of this work is to study modeling of chromium (III) removal from aqueous solution using activated carbon as adsorbent. Studies have been conducted in a continuous fixed bed packed column under different operating conditions such as bed height, flow rate, fluid velocity and fixed adsorbent particle size. The Yoon Nelson model was applied to experimental data to predict the breakthrough curves by calculating the rate constant k and 50 % breakthrough time, θ. The Bed Depth Service Time (BDST) was applied to determine BDST constant K and the capacity of adsorbent, No. Results obtained from both models are compared with the experimental breakthrough curves and a satisfactory agreement was noticed. Therefore, the Yoon - Nelson and BDST models were found suitable for determining the parameters of the column design. The Y 000 - Nelson model was found more accurate in representing the system in comparison with the BDST model although it is less complicated than other models

  12. Grid Integration of Offshore Wind Farms via VSC-HVDC – Dynamic Stability Study

    DEFF Research Database (Denmark)

    Liu, Hongzhi

    farms could seriously impact the operation and stability of their interconnected power system. To assist in maintaining the power system stability when large disturbances occur in the grid, modern offshore wind farms consisting of variable-speed wind turbines are required to provide ancillary services...... such as voltage and frequency control. The greater distance to shore makes commonly used high voltage AC (HVAC) connection unsuitable economically and technically for large offshore wind farms. Alternatively, voltage source converter (VSC)-based high voltage DC (HVDC) transmission becomes more attractive...... and practical to integrate large-scale offshore wind farms into the onshore power grid, owing to its high capacity, advanced controllability and stabilization potential for AC networks etc. In this dissertation, some of the key technical issues with grid integration of large-scale offshore wind farms via VSC...

  13. Coherent Backscattering: Conceptions and Misconceptions (Reply to Comments by Bruce W. Hapke and Robert M. Nelson)

    Science.gov (United States)

    Tishkovets, Victor P.; Mishchenko, Michael

    2010-01-01

    Although the note by Hapke and Nelson has virtually no relevance to our original publication, it contains a number of statements that are misleading and/or wrong. We, therefore, use this opportunity to dispel several profound misconceptions that continue to hinder the progress in remote sensing of planetary surfaces.

  14. Radical Questioning on the Long Walk to Freedom: Nelson Mandela and the Practice of Critical Reflection

    Science.gov (United States)

    Brookfield, Stephen

    2008-01-01

    Nelson Mandela's autobiography "The Long Walk to Freedom" describes how an iconic political activist and freedom fighter reflected on, and sometimes modified, four core assumptions at the heart of his struggle to overturn the White supremacist, minority hegemony and create a free South Africa. Critical reflection's focus is on…

  15. Implementation of the production management of a HVDC overlaydistribution system in the load frequency control of a three-phase-current combined systems; Integration der Betriebsfuehrung eines HGUe-Overlay-Netzes in die Leistungs-Frequenz-Regelung eines Drehstrom-Verbundnetzes

    Energy Technology Data Exchange (ETDEWEB)

    Marten, Anne-Katrin

    2012-07-01

    To reduce emission of carbon dioxide the proportion of renewable energies is rapidly growing in German and European grids in general. Additionally, the bulk of them are generated in only a few spots in European transmission grid, whereas conventional power plants will shut down and the load center distribution will still be decentralized. This results in the need of a new and powerful transmission grid, which is able to transport bulk power over long distances. To overcome this challenge one of the discussed solutions for Europe is an Overlay Network based on HVDC technology connecting spots of bulk renewable energy plants and important load centers. Because of different performance compared to an ac grid, it is necessary for an HVDC Overlay Network to actively sustain system services such as power frequency control to ensure system stability and power quality as well as the ac grid does. A novel method for realizing participation of a HVDC Overlay Network in power frequency control is presented. It hasn't only an advantage for load frequency power flows, but also for contracted balancing power flows which are also feed via the dc grid pro rata. Numerical case studies are made to show some benefits of this method in case of various disturbances. It is shown that a HVDC Overlay Network with the developed operating control releases the ac grid by an adjustable amount of power flows and improves the power frequency control for example in terms of promptness and lower frequency deviations.

  16. Integration of the work management of a HVDC overlay grid into the line-frequency control of a three-phase current integrated nework; Integration der Betriebsfuehrung eines HGUe-Overlay-Netzes in die Leitungs-Frequenz-Regelung eines Drehstrom-Verbundnetzes

    Energy Technology Data Exchange (ETDEWEB)

    Marten, Anne-Katrin

    2012-07-01

    To reduce emission of carbon dioxide the proportion of renewable energies is rapidly growing in German and European grids in general. Additionally, the bulk of them are generated in only a few spots in European transmission grid, whereas conventional power plants will shut down and the load center distribution will still be decentralized. This results in the need of a new and powerful transmission grid, which is able to transport bulk power over long distances. To overcome this challenge one of the discussed solutions for Europe is an Overlay Network based on HVDC technology connecting spots of bulk renewable energy plants and important load centers. Because of different performance compared to an ac grid, it is necessary for an HVDC Overlay Network to actively sustain system services such as power frequency control to ensure system stability and power quality as well as the ac grid does. A novel method for realizing participation of a HVDC Overlay Network in power frequency control is presented. It hasn't only an advantage for load frequency power flows, but also for contracted balancing power flows which are also feed via the dc grid pro rata. Numerical case studies are made to show some benefits of this method in case of various disturbances. It is shown that a HVDC Overlay Network with the developed operating control releases the ac grid by an adjustable amount of power flows and improves the power frequency control for example in terms of promptness and lower frequency deviations.

  17. Nelson Rodrigues e o Rio de Janeiro: memórias de um passional

    Directory of Open Access Journals (Sweden)

    Ângela Maria Dias

    2005-06-01

    Full Text Available A crônica de Nelson Rodrigues, ao ser escrita do ponto de vista do homem comum - no diapasão do "pobre-diabo de um terno só" -, propicia a fundação de uma voz fronteiriça, entre o banal e o singular, e realiza a profissão de fé antiintelectualista e anti-retórica, característica da obra em suas diversas modalidades. A cidade do Rio de Janeiro, vitrine do Brasil durante as décadas de 1960 e 1970, constitui o protagonista do texto e opera a linguagem de modo a recriar seus espaços. O artista desdobra a sua imaginação totalizante em opostas e simétricas dimensões, a pornográfica e a mística, ou a do erotômano e a do "convertido". A dramatização pública do "reacionário" constitui, então, a resposta ritualística e sacrificial ao "revolucionário de esquerda" dos anos 1960, na prática renovada das formas totalizantes de pensamento.La crónica de Nelson Rodrigues, escrita del punto de vista del hombre común - en el disyuntiva del "pobre-hombre de traje único" - propicia la fundación de una voz fronteriza, entre lo banal y lo singular, y realiza la profesión de fé antiintelectualista y antirretórica, característica de la obra, en sus diversas modalidades. Rio de Janeiro, ciudad escaparate de Brasil durante las décadas de los 60 y 70, constituye el protagonista del texto y opera el lenguaje de modo a recriar sus espacios. El artista desdobla su imaginación totalizante en opuestas y simétricas dimensiones, la pornográfica y la mística, o la del erotómano y la del "convertido". La dramatización pública del "reacccionario" constituye, entonces, la respuesta del ritual y del sacrifício al "revolucionario de izquierda" de los años 60, en la práctica renovada de las formas totalizantes de pensamiento.Written from the point of view of the common man, Nelson Rodrigues' chronicle founds a bordering voice between the trivial and the singular and realizes an antiintellectualistic profession of faith. The city of Rio de

  18. Enhancing the reliability of AC transmission networks by using a long distance HVDC-link

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Marco; Balzer, Gerd; Wasserrab, Andreas; Neumann, Claus [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power and Energy

    2012-07-01

    The absorption of energy from offshore wind farms is a difficult task for Transmission system operators (TSO) in Germany, even if no offshore wind farm is connected directly. The role of the TSOs in the north it is to transport this energy to the south of Germany. The transmission capacities of overhead lines are limited. With the expected rapid expansion of wind farms, this is no longer enough. Thus, the transmission system must be enhanced. One possibility is the installation of an HVDC link from north to south between two main substations in the 380 kV network. Based on a realistic case study, the impact of such a link on the reliability of the entire extra high voltage network is shown. (orig.)

  19. Coordinated Voltage Control in Offshore HVDC Connected Cluster of Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Rather, Zakir Hussain; Rimez, Johan

    2016-01-01

    This paper presents a coordinated voltage control scheme (CVCS) for a cluster of offshore wind power plants (OWPPs) connected to a VSC HVDC system. The primary control point of the proposed voltage control scheme is the introduced Pilot bus, which is having the highest short circuit capacity...... in the offshore AC grid. The developed CVCS comprehends an optimization algorithm, aiming for minimum active power losses in the offshore grid, to generate voltage reference to the Pilot bus. During steady state operation, the Pilot bus voltage is controlled by dispatching reactive power references to each wind...... turbine (WT) in the WPP cluster based on their available reactive power margin and network sensitivity based participation factors, which are derived from the dV/dQ sensitivity of a WT bus w.r.t the Pilot bus. This method leads to minimization of the risk of undesired effects, particularly overvoltage...

  20. Protection of Multi-Terminal VSC-HVDC Grids Based on the Response of the First Carrier Frequency Harmonic Current

    DEFF Research Database (Denmark)

    Ashouri, Mani; Khazraj, Hesam; Silva, Filipe Miguel Faria da

    This paper investigates the response of first carrier frequency harmonic (FCFH) current for designing a protection algorithm for multi-terminal Voltage source converter-based HVDC (VSC-MTDC) transmission grids. This transient harmonic current has been used before, to discriminate external AC faults...... various kinds of faults with different locations and resistances. This paper will also consider half-bridge MMC instead of two-level VSCs to test the sensitivity of the FCFH based algorithm for lower harmonic values. A modified meshed version of CIGRE DC model has been used in PSCAD and the signal...

  1. A DIPLOMACIA DE PRESTÍGIO NA ÁFRICA DO SUL DE NELSON MANDELA (1994-1999

    Directory of Open Access Journals (Sweden)

    Pedro Vinícius Pereira Brites

    2017-09-01

    Full Text Available O presente estudo tem como objetivo analisar a política externa do governo Nelson Mandela na esteira de uma nova estrutura internacional pós-Guerra Fria, no período de 1994 a 1999, mapeando os atores envolvidos neste meio e os indicadores e variáveis que condicionavam a política externa do país.

  2. Nelson's syndrome: single centre experience using the linear accelerator (LINAC) for stereotactic radiosurgery and fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Wilson, Peter J; Williams, Janet R; Smee, Robert I

    2014-09-01

    Nelson's syndrome is a unique clinical phenomenon of growth of a pituitary adenoma following bilateral adrenalectomies for the control of Cushing's disease. Primary management is surgical, with limited effective medical therapies available. We report our own institution's series of this pathology managed with radiation: prior to 1990, 12 patients were managed with conventional radiotherapy, and between 1990 and 2007, five patients underwent stereotactic radiosurgery (SRS) and two patients fractionated stereotactic radiotherapy (FSRT), both using the linear accelerator (LINAC). Tumour control was equivocal, with two of the five SRS patients having a reduction in tumour volume, one patient remaining unchanged, and two patients having an increase in volume. In the FSRT group, one patient had a decrease in tumour volume whilst the other had an increase in volume. Treatment related morbidity was low. Nelson's syndrome is a challenging clinical scenario, with a highly variable response to radiation in our series. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Notes on the influence of Carlos Nelson Coutinho on Social Work in Brazil

    Directory of Open Access Journals (Sweden)

    Mabile Caetano Cazela

    2017-06-01

    Full Text Available The paper reports some results of a research study conducted for the master’s thesis in Social Work entitled Fundamental ethical principles of Social Work in Brazil: a study on the influence of Carlos Nelson Coutinho. It is based on bibliographic and field research, and it identifies and recognizes the influence of Coutinho on Social Work, as well as the intellectual contribution of Social Workers that are members of the Code of Ethics Revision Committee.

  4. YBCO single crystals I-V characteristics nonlinearity and Nelson-Kosterlitz jump

    International Nuclear Information System (INIS)

    Kuzmichev, N.D.; Vasyutin, M.A.; Golovashkin, A.I.

    2007-01-01

    Temperature dependences of I-V characteristics and voltage harmonics V n (T) (n = 2, 3, ...) have been investigated in magnetic fields up to 200 Oe for single crystals YBa 2 Cu 3 O 7-x . It was shown that V n (T) had asymmetric peak form with maximum at T* = 92.0 K. Amplitudes of V n (T) were decreased in magnetic fields. The results were explained on the base of the Berezinskii-Kosterlitz-Thouless (BKT) transition model. It was shown that T* coincided with the BKT transition temperature T BKT . The asymmetric peaks of V n (T) are a consequence of the Nelson-Kosterlitz jump

  5. An Annotated Bibliography of HVDC Transmission and FACTS Devices, 1996-1997.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne H.; Varma, Rajiv K.; Flanagan, John D. [eds.

    1998-06-01

    This edition of the Annotated Bibliography of HVDC Transmission and FACTS Devices continues work begun in 1962 by the late Erik Bromberg, Bonneville Power Administration Librarian. His original bibliography covered the period 1932--1962. Subsequent editions were compiled by Bromberg, Val S. Lava, and Wayne Litzenberger, all of Bonneville Power Administration. Beginning with the 1991--1993 edition, the scope of the bibliography was expanded to include flexible ac transmission (FACTS) devices. This 1996--1997 edition also contains information for 1998. Preparation of the present edition took place primarily in May-June of 1998. All pertinent references have been included that were available to the editors at the time of preparation. Papers for the 1998 IEEE Winter and Summer Power Meetings and 1998 T and D Conference have been included. This edition contains the organizational affiliation of the first-named author as an aid to accessing the reference. Unfortunately, space limitations prevented the inclusion of the affiliations of all authors. Some minor editorial changes have been made to abstracts to ensure consistency in style and syntax.

  6. Heat control in HVDC resistive divider by PID and NN controllers

    International Nuclear Information System (INIS)

    Yilmaz, S.; Dincer, H.; Eksin, I.; Kalenderli, O.

    2007-01-01

    In this study, a control system is presented that is devised to increase measurement precisions within a prototype high voltage DC resistive divider (HVDC-RD). Since one of the major sources of measurement errors in such devices is the self heating effect, a system controlling the temperature within the high voltage DC resistive divider is devised so that suitable and stable temperature conditions are maintained that, in return, will decrease the measurement errors. The resistive divider system is cooled by oil, and PID and neural network (NN) controllers try to keep the temperature within the prescribed limits. The system to be controlled exhibits a nonlinear character, and therefore, a control approach based on NN controllers is proposed. Thus, a system that can fulfill the various requirements dictated by the designer is constructed. The performance of the NN controller is compared with that of the PID controller developed for the same purpose, and the values of the performance indices indicate the superiority of the NN controller over that of the classical PID controller

  7. Barriers and solutions for AC low voltage fault ride-through on multi-terminal HVDC grids

    Energy Technology Data Exchange (ETDEWEB)

    Silva, B.; Moreira, C.L.; Leite, H.; Pecas Lopes, J.A. [Porto Univ. (Portugal). Dept. de Engenharia Electrotecnica e de Computadores (DEEC); Tecnologia e Ciencia, Porto (Portugal). Inst. de Engenharia de Sistemas e Computadores (INESCTEC)

    2012-07-01

    This work analyzes the multi-terminal DC grids dynamics under AC mainland grid fault events envisioning to assess the feasibility of fault ride-through provision. The major bottleneck related with the operation under AC fault consists on the DC side power imbalance that takes place due to the HVDC converter current limits and consequent incapability of delivering all the generated power to the grid. It was also verified that the power imbalance leads to a DC overvoltage occurrence. The mechanism of including chopper devices at the onshore converters DC terminals has been studied as a mean of power equilibrium promotion. Simulations comparing the both cases were performed and the comparison and the effectiveness of the adopted approach are also presented. (orig.)

  8. Cost and Benefit Analysis of VSC-HVDC Schemes for Offshore Wind Power Transmission

    Institute of Scientific and Technical Information of China (English)

    Sheng WANG; Chunmei FENG; An WEN; Jun LIANG

    2013-01-01

    Due to low load factors of wind power generation,it is possible to reduce transmission capacity to minimize the cost of transmission system construction.Two VSC-HVDC schemes for offshore wind farm,called the point to point (PTP) and DC mesh connections are compared in terms of the utilization of transmission system and its cost.A Weibull distribution is used for estimating offshore wind power generation,besides,the cross correlation between wind farms is considered.The wind energy curtailment is analyzed using the capacity output possibility table (COPT).The system power losses,costs of transmission investment and wind energy curtailment are also computed.A statistic model for the wind generation and transmission is built and simulated in MATLAB to validate the study.It is concluded that a DC mesh transmission can reduce the energy curtailment and power losses.Further benefit is achievable as the wind cross correlation between wind farms decreases.

  9. Large-scale wind energy application. Transporting wind energy over long distances using an HVDC transmission line, in combination with hydro energy or biomass energy

    International Nuclear Information System (INIS)

    Coelingh, J.P.; Van Wijk, A.J.M.; Betcke, J.W.H.; Geuzendam, C.; Gilijamse, W.; Westra, C.A.; Curvers, A.P.W.M.; Beurskens, H.J.M.

    1995-08-01

    The main objective of the study on the title subject is to assess the long-term prospects for large-scale application of wind energy, in combination with hydro energy in Norway and in combination with biomass energy in Scotland. These countries have high wind resource areas, however they are located far away from load centres. The development of new transmission technologies as High Voltage Direct Current (HVDC) transmission lines, in combination with highly suitable places for wind energy in Norway and Scotland, forms the driving force behind this study. The following two cases are being considered: (1) a large-scale wind farm (1,000 MW) in Norway from which electricity is transmitted to The Netherlands by using an HVDC transmission line, in combination with hydro energy. Hydro energy already makes a large contribution to the energy supply of Norway. Wind farms can contribute to the electricity production and save hydro energy generated electricity and make the export of electricity profitable; and (2) a large-scale wind farm (1,000 MW) in Scotland from which electricity is transmitted to The Netherlands by using an HVDC transmission line, in combination with biomass energy. Scotland has a large potential for biomass production such as energy crops and forestry. Poplars and willows cultivated on set-aside land can be gasified and fed into modern combined-cycle plants to generate electricity. In Scotland the usable potential of wind energy may be limited in the short and medium term by the capacity of the grid. New connections can overcome this constraint and allow wind energy to be treated as a European Union resource rather than as a national resource. Thus, the concept of this study is to look at the possibilities of making a 1,000 MW link from The Netherlands to Norway or to Scotland, in order to supply electricity at competitive costs generated with renewable energy sources. 16 figs., 24 tabs., 80 refs

  10. Impacts of large-scale offshore wind farm integration on power systems through VSC-HVDC

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2013-01-01

    The potential of offshore wind energy has been commonly recognized and explored globally. Many countries have implemented and planned offshore wind farms to meet their increasing electricity demands and public environmental appeals, especially in Europe. With relatively less space limitation......, an offshore wind farm could have a capacity rating to hundreds of MWs or even GWs that is large enough to compete with conventional power plants. Thus the impacts of a large offshore wind farm on power system operation and security should be thoroughly studied and understood. This paper investigates...... the impacts of integrating a large-scale offshore wind farm into the transmission system of a power grid through VSC-HVDC connection. The concerns are focused on steady-state voltage stability, dynamic voltage stability and transient angle stability. Simulation results based on an exemplary power system...

  11. Economics and a novel voltage conversion technique associated with exporting Wyoming's energy by HVDC transmission

    Science.gov (United States)

    Xu, Kaili

    Wyoming is by far the largest coal producing state in the US, but local utilization is extremely low. As much as 92% of Wyoming's coal is shipped to the other states and is mainly consumed by their electricity producers. Coal accounts for more than 50% of the US electricity generation and is one of the least expensive energy sources. Wyoming could utilize its coal better by exporting electricity instead of exporting the coal only in its raw form. Natural gas is another important energy resource in Wyoming but local utilization is even lower. As a result of the development in coalbed methane fields, natural gas production in Wyoming is almost in pace with its coal production. In addition to constructing more new pipelines, new transmission lines should be considered as an alternative way of exporting this energy. Because of their enormous electricity market sizes and high electricity prices, California, Texas and Illinois are chosen to be the target markets for Wyoming's electricity. The proposed transmission schemes use High Voltage DC (HVDC) lines, which are suitable for long distance and cross-system power transmission. Technical and economic feasibilities are studied in details. The Wyoming-California scheme has a better return of investment than both the Wyoming-Texas and the Wyoming-Illinois schemes. A major drawback of HVDC transmission is the high level of harmonics generated by the converters. Elaborate filtering is required at both the AC and the DC sides. A novel pulse-multiplication method is proposed in the thesis to reduce the harmonics from the converter source. By introducing an averaging inductor, the proposed method uses less thyristors to achieve the same high-pulse operation as the existing series scheme. The reduction of thyristors makes the switching circuit more reliable and easier to control and maintain. Harmonic analysis shows that the harmonic level can be reduced to about one third of the original system. The proposed method is also

  12. Caesarean section deliveries: Experiences of mothers of midwifery care at a public hospital in Nelson Mandela Bay

    Directory of Open Access Journals (Sweden)

    Thobeka P. Jikijela

    2018-01-01

    Conclusion: Experiences of mothers following a caesarean section delivery with midwifery services at a public hospital in Nelson Mandela Bay were explored and described as diverse. A need for adequate pain management as well as assistance and breastfeeding support to mothers following caesarean delivery was identified as crucial to promote a good mother-to-child relationship.

  13. Analysis of disabled HVDC transformer

    International Nuclear Information System (INIS)

    Hestad, Oeystein; Linhjell, Dag

    2006-02-01

    An examination of three windings from a disabled Hvdc transformer. The windings were dismantled at the company ABB Drammen. Test were taken and brought to Trondheim for further analysis. Of the three windings, two were strongly contaminated by copper sulphite while the last one recently had been replaced after a previous breakdown and only showed small signs of copper sulphite contamination. The following analyses have been conducted: visual observation of copper sulphite contamination on the conductors/paper, electron microscope analysis of the surface of selected bits of paper, measuring of the conducing ability by means of examining paper samples of varying degrees of contamination, and GC-AED and combustion analysis of the disabled transformer's oil and the oil from a 'healthy' transformer. The visual examination showed a strong contamination of the upper (hot) parts of the windings as well as two areas just below the middle of the windings. The contamination was especially strong under the buttons and between the conductors where the oil flow is reduced compared to the areas where the paper is in direct contact with free flow of oil. The degree of contamination on the paper proved to be directly correlated to the electric conducing ability through the paper and the amount of copper and sulphur measured in the electron microscope analysis. Copper sulphite grows through the paper, but the 'contamination' between the layers of paper is fastest through the gaps. When copper sulphite grows through the paper via the gaps, a current causes carbonisation of the paper in the area, and finally a short circuit between the windings. A comparison between the two oil samples that were analyzed by GC-AED and combustion analysis showed that the two oils probably were similar to begin with. The total amount of sulphur components in the oil from the disabled transformer has thus increased during the lifetime of the transformer. The new sulphur components have probably been

  14. 'Take the long way down': Integration of large-scale North Sea wind using HVDC transmission

    International Nuclear Information System (INIS)

    Weigt, Hannes; Jeske, Till; Leuthold, Florian; Hirschhausen, Christian von

    2010-01-01

    We analyze the impact of extensive wind development in Germany for the year 2015, focusing on grid extensions and price signals. We apply the electricity generation and network model ELMOD to compare zonal, nodal, and uniform pricing approaches. In addition to a reference case of network extensions recommended by the German Energy Agency (Dena), we develop a scenario to transmit wind energy to major load centers in Western and Southern Germany via high-voltage direct current (HVDC) connections. From an economic-engineering standpoint, our results indicate that these connections are the most economic way to manage the integration of large-scale offshore wind resources, and that nodal pricing is most likely to determine the locales for future investment to eliminate congestion. We conclude with a description of the model's potential limitations.

  15. Perceptions of patient-centred care at public hospitals in Nelson Mandela Bay

    Directory of Open Access Journals (Sweden)

    Sihaam Jardien-Baboo

    2016-10-01

    Full Text Available In South Africa, the quality of health care is directly related to the concept of patient-centred care and the enactment of the Batho Pele Principles and the Patients' Rights Charter. Reports in the media indicate that public hospitals in the Eastern Cape Province are on the brink of collapse, with many patients being treated in condemned hospitals which lacked piped water, electricity and essential medical equipment. Receiving quality care, and principally patient-centred care, in the face of such challenges is unlikely and consequently leads to the following question: “Are patients receiving patient-centred care in public hospitals?” A qualitative, explorative, descriptive and contextual study was conducted to explore and describe the perceptions of professional nurses regarding patient-centred care in public hospitals in Nelson Mandela Bay. Semi-structured interviews were conducted with a total of 40 purposively selected professional nurses working in public hospitals in Nelson Mandela Bay, Eastern Cape Province. Interviews were analysed according to the method described by Tesch in Creswell (2009:192. Professional nurses perceive patient-centred care as an awareness of the importance of the patient's culture, involving the patient's family, incorporating values of love and respect, optimal communication in all facets of patient care and accountability to the patient. Factors which enable patient-centred care were a positive work environment for staff, nursing manager's demonstrating exemplary professional leadership, continuous in service education for staff and collaborative teamwork within the interdisciplinary team. Barriers to patient-centred care were a lack of adequate resources, increased administrative work due to fear of litigation and unprofessional behaviour of nursing staff.

  16. Commentary: The Development of Hippocampal-Dependent Memory Functions: Theoretical Comments on Jabès and Nelson Review (2015)

    Science.gov (United States)

    Bachevalier, Jocelyne

    2015-01-01

    Studies investigating the development of memory processes and their neural substrates have flourished over the past two decades. The review by Jabès and Nelson (2015) adds an important piece to our understanding of the maturation of different elements and circuits within the hippocampal system and their association with the progressive development…

  17. The late Pleistocene glacial sequence in the middle Maruia valley, southeast Nelson, New Zealand

    International Nuclear Information System (INIS)

    Mabin, M.C.G.

    1983-01-01

    Glacial and fluvioglacial landforms and deposits preserved in the middle reaches of the Maruia valley, southeast Nelson, New Zealand, record the activity of the Maruia glacier during the late Pleistocene Otira Glaciation. Five advances are recognised, from oldest to youngest: Creighton 1, 2, 3, and the Reid Stream 1, 2 advances. There was an interstadial interval between the Creighton 3 and Reid Stream 1 advances. The Reid Stream 1 advance occurred shortly after 14 800 years B.P. (NZ536, old T/sub 0.5/). (auths)

  18. Development of toroid-type HTS DC reactor series for HVDC system

    Science.gov (United States)

    Kim, Kwangmin; Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho; Lee, Sangjin; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2015-11-01

    This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  19. A coordinated multivariable control system design for a HVDC linked remote ABWR nuclear power park

    International Nuclear Information System (INIS)

    Hara, T.; Kurita, A.; Younkins, T.D.; Sanchez-Gasca, J.J.; Chow, J.H.

    1987-01-01

    This paper presents a conceptual design of a coordinated output feedback multivariable control system for a remote nuclear generation park connected to a load area with an HVDC link. The control design presented in this paper is for both normal operation (e.g., load following and frequency regulation) and contingencies (e.g., loss of a dc bipole or loss of two nuclear reactors). The design is simple and compact: four control signals, five measurements, and the integrals of two measurements are used to meet all the objectives and constraints for normal operation and contingencies. The multivariable control coordinates the measurements and controls according to the time frame of response and the amount of interactions between variables. This paper describes the model of the system, the multivariable control design, and the nonlinear time domain simulation of the overall system performance

  20. Quantum cybernetics: a new perspective for Nelson's stochastic theory, nonlocality, and the Klein-Gordon equation

    Science.gov (United States)

    Grössing, Gerhard

    2002-04-01

    The Klein-Gordon equation is shown to be equivalent to coupled partial differential equations for a sub-quantum Brownian movement of a “particle”, which is both passively affected by, and actively affecting, a diffusion process of its generally nonlocal environment. This indicates circularly causal, or “cybernetic”, relationships between “particles” and their surroundings. Moreover, in the relativistic domain, the original stochastic theory of Nelson is shown to hold as a limiting case only, i.e., for a vanishing quantum potential.

  1. Megavoltage pituitary irradiation in the management of Cushing's disease and Nelson's syndrome: long-term follow-up

    International Nuclear Information System (INIS)

    Howlett, T.A.; Plowman, P.N.; Wass, J.A.H.; Rees, L.H.; Jones, A.E.; Besser, G.M.

    1989-01-01

    The authors report the long-term follow-up (up to 17.3 years) of the clinical and biochemical effects of megavoltage pituitary irradiation (radiotherapy;RT), administered as primary or secondary therapy, for pituitary Cushing's disease and Nelson's syndrome in 52 patients. Irradiation was administered, from a 4-15 MeV linear accelerator, via a three-field technique, to a total dose of 4500 cGy (rad) in 25 fractions over 35 days. (author)

  2. Approches pour la reduction de l'impact de defaut dans le transport d'energie du parc eolien offshore via VSC-HVDC =

    Science.gov (United States)

    Benadja, Mounir

    Dans ce travail est presente un systeme de generation d'energie d'un parc eolien offshore et un systeme de transport utilisant les stations VSC-HVDC connectees au reseau principal AC onshore. Trois configurations ont ete etudiees, modelisees et validees par simulation. Dans chacune des configurations, des contributions ameliorant les cotes techniques et economiques sont decrites ci-dessous : La premiere contribution concerne un nouvel algorithme MPPT (Maximum Power Point Tracking) utilise pour l'extraction de la puissance maximale disponible dans les eoliennes des parcs offshores. Cette technique d'extraction du MPPT ameliore le rendement energetique de la chaine de conversion des energies renouvelables notamment l'energie eolienne a petite et a grande echelles (parc eolien offshore) qui constitue un probleme pour les constructeurs qui se trouvent confrontes a developper des dispositifs MPPT simples, moins couteux, robustes, fiables et capable d'obtenir un rendement energetique maximal. La deuxieme contribution concerne la reduction de la taille, du cout et de l'impact des defauts electriques (AC et DC) dans le systeme construit pour transporter l'energie d'un parc eolien offshore (OWF) vers le reseau principal AC onshore via deux stations 3L-NPC VSCHVDC. La solution developpee utilise des observateurs non-lineaires bases sur le filtre de Kalman etendu (EKF). Ce filtre permet d'estimer la vitesse de rotation et la position du rotor de chacune des generatrices du parc eolien offshore et de la tension du bus DC de l'onduleur DC-AC offshore et des deux stations 3L-NPC-VSC-HVDC (offshore et onshore). De plus, ce developpement du filtre de Kalman etendu a permis de reduire l'impact des defauts AC et DC. Deux commandes ont ete utilisees, l'une (commande indirect dans le plan abc) avec EKF integre destinee pour controler le convertisseur DC-AC offshore et l'autre (commande d-q) avec EKF integre pour controler les convertisseurs des deux stations AC-DC et DC-AC tout en

  3. The divine clockwork: Bohr's correspondence principle and Nelson's stochastic mechanics for the atomic elliptic state

    International Nuclear Information System (INIS)

    Durran, Richard; Neate, Andrew; Truman, Aubrey

    2008-01-01

    We consider the Bohr correspondence limit of the Schroedinger wave function for an atomic elliptic state. We analyze this limit in the context of Nelson's stochastic mechanics, exposing an underlying deterministic dynamical system in which trajectories converge to Keplerian motion on an ellipse. This solves the long standing problem of obtaining Kepler's laws of planetary motion in a quantum mechanical setting. In this quantum mechanical setting, local mild instabilities occur in the Keplerian orbit for eccentricities greater than (1/√(2)) which do not occur classically

  4. Profound amplification of secretory-burst mass and anomalous regularity of ACTH secretory process in patients with Nelson's syndrome compared with Cushing's disease

    NARCIS (Netherlands)

    van Aken, Maarten O.; Pereira, Alberto M.; van den Berg, Gerrit; Romijn, Johannes A.; Veldhuis, Johannes D.; Roelfsema, Ferdinand

    2004-01-01

    As described originally, Nelson's syndrome is characterized by grossly elevated ACTH concentrations, a sellar mass and skin hyperpigmentation emerging in the course of Cushing's disease after bilateral adrenalectomy. No detailed studies have defined whether the mechanisms directing ACTH secretion

  5. Wide area stability analysis and control of interconnected power systems with HVDC and FACTS devices

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yong

    2012-11-01

    In order to damp low-frequency oscillations and improve the overall stability of large-scale interconnected power systems, this book investigates the wide-area stability analysis and control methods from different perspectives. The flexible and fast control capability of high-voltage (FACTS) is investigated in detail to implement a wide-area measurement based damping control. A sequential and global mixed optimization method is proposed to simultaneously optimize local and wide area damping controllers. A wide-area robust coordination method is presented to coordinate multiple wide-area damping controllers (WADC). A delay-dependent robust design method is also proposed to handle time-varying delays commonly existing in wide-area signal communication. A closed-loop hardware experiment is used to validate the damping performance. The research activities of this book include power system stability analysis and control, wide-area damping control as well as HVDC and FACTS technologies.

  6. Fathers of the Nation: Barack Obama Addresses Nelson Mandela

    Directory of Open Access Journals (Sweden)

    Elisa Bordin

    2014-11-01

    Full Text Available This essay analyzes Barack Obama’s Nelson Mandela Memorial speech together with other seminal texts of Obama’s political and personal creed, such as his book Dreams from My Father (1995 and his speech “A More Perfect Union” (2008. This reading becomes helpful to understand Mandela’s transnational power, which Obama uses to comment on the United States by comparing Madiba to other American “fathers of the nation.” Thus, he uproots Mandela’s from a specifically South African legacy, expands his figure, and addresses him as a transnational father of his own nation, whose power, influence, and example transcend South African borders. As a consequence of this enlargement and transnational validation of Mandela’s figure, the speech delivered at the Memorial becomes an occasion to tackle American past and future, while the memory of Madiba and his driving example in Obama’s life serve to reinforce previous positions conveyed in other discourses by the American President, such as the “A More Perfect Union” speech delivered in Philadelphia in 2008.

  7. Caesarean section deliveries: Experiences of mothers of midwifery care at a public hospital in Nelson Mandela Bay.

    Science.gov (United States)

    Jikijela, Thobeka P; James, Sindiwe; Sonti, Balandeli S I

    2018-01-30

    The rate of caesarean section deliveries has increased globally and mothers are faced with challenges of postoperative recovery and caring thereof. Midwives have a duty to assist these mothers to self-care. The objective was to explore and describe experiences of post-caesarean section delivered mothers of midwifery care at a public hospital in Nelson Mandela Bay. A qualitative, descriptive and explorative research design was used in the study. Data were collected from 11 purposively criterion-selected mothers who had a caesarean section delivery. One-on-one semi-structured interviews were conducted in the post-natal wards. Research ethics, namely autonomy, beneficence, justice and informed consent, were adopted in the study. All participants were informed of their right to withdraw from the study at any stage without penalties. Interviews were analysed using Tesch's method of data analysis. Three main themes were identified as experiences of: diverse pain, physical limitation and frustration and health care services as different. Experiences of mothers following a caesarean section delivery with midwifery services at a public hospital in Nelson Mandela Bay were explored and described as diverse. A need for adequate pain management as well as assistance and breastfeeding support to mothers following caesarean delivery was identified as crucial to promote a good mother-to-child relationship.

  8. Glacial Meltwater Contirbutions to the Bow River, Alberta, Canada

    Science.gov (United States)

    Bash, E. A.; Marshall, S. J.; White, E. C.

    2009-12-01

    Assessment of glacial melt is critical for water resource management in areas which rely on glacier-fed rivers for agricultural and municipal uses. Changes in precipitation patterns coupled with current glacial retreat are altering the glacial contribution to river flow in areas such as the Andes of South America and the high ranges of Asia, as well as the Rockies of Western Canada. Alberta’s Bow River has its headwaters in the eastern slopes of the Canadian Rockies and contributes to the Nelson drainage system feeding into Hudson Bay. The Bow River basin contains several population centers, including the City of Calgary, and is heavily taxed for agricultural use. The combined effects of rapid glacial retreat in the Canadian Rockies, higher drought frequency, and increased demand are likely to heighten water stress in Southern Alberta. However, there has been little focus to date on the extent and importance of glacial meltwater in the Bow River. The Bow River contains 74.5 km2 of glacier ice, which amounts to only 0.29% of the basin. While this number is not high compared to some glacierized areas, Hopkinson and Young (1998) report that in dry years, glacier melt can provide up to 50% of late summer flows at a station in the upper reaches of the river system. We extend this work with an assessment of monthly and annual glacial contributions to the Bow River farther downstream in Calgary. Our analysis is based on mass balance, meteorological, and hydrological data that has been collected at the Haig Glacier since 2001. This data is used in conjunction with glacier coverage and hypsometric data for the remainder of the basin to estimate seasonal snow and glacial meltwater contributions to the Bow River from the glacierized fraction of the catchment. The results of this study show the percentage of total flow attributed to glacial melt to be highly variable. Glacier runoff contributes up to an order of magnitude more water to the Bow River per unit area of

  9. Generalisability of the results of the Dutch-Belgian randomised controlled lung cancer CT screening trial (NELSON) : Does self-selection play a role?

    NARCIS (Netherlands)

    van der Aalst, C. M.; van Iersel, C. A.; van Klaveren, R. J.; Frenken, F. J. M.; Fracheboud, J.; Otto, S. J.; de Jong, P. A.; Oudkerk, M.; de Koning, H. J.

    The degree of self-selection in the Dutch-Belgian randomised controlled lung cancer screening trial (NELSON) was determined to assess the generalisability of the study results. 335,441 (mainly) men born in 1928-1953 received a questionnaire. Of the respondents (32%), eligible subjects were invited

  10. Does Deafness Spell Disaster? An Analysis of the Written English Levels of Deaf Children in the Nelson Mandela Metropole, South Africa

    Science.gov (United States)

    Weir, Carolyn; Aylif, Diana

    2014-01-01

    This article presents the findings of an empirical comparative study in the Nelson Mandela Metropole investigating the difference between the written English of deaf children and the written English of hearing children and makes recommendations on how to improve the writing of deaf children. The psycholinguistic approach was used for the…

  11. Crecimiento en clavel estándar cv. Nelson, en suelo y en sustratos Crescimento de cravo estandar cv. Nelson, em solo e em substratos Growth of standard carnation cv. Nelson, in soil and substrates

    Directory of Open Access Journals (Sweden)

    Adriana Del Pilar Baracaldo Argüello

    2010-01-01

    Full Text Available El cultivo de clavel en la sabana de Bogotá ha sido importante, ya que representa en la actualidad el segundo lugar de exportación en flores de corte. Recientemente, su producción en sistema de cultivo en sustrato ha aumentado debido fundamentalmente a limitantes de tipo sanitario, por lo cual es importante el estudio del crecimiento de las plantas establecidas en este sistema de cultivo. El objetivo de este estudio fue evaluar el crecimiento del clavel estándar cv. Nelson establecido en sustratos y en suelo, a segundo pico de cosecha, para lo cual, en el SENA - Centro Multisectorial de Mosquera, plantas de clavel se sometieron a los siguientes tratamientos: 100% de cascarilla de arroz quemada; 65% cascarilla de arroz quemada - 35% fibra de coco; 35% cascarilla de arroz quemada - 65% fibra de coco y suelo. En muestreos continuos se evaluaron las variables número de hojas, longitud del tallo, diámetro de tallo, número de nudos y diámetro y longitud del botón floral y se ajustaron curvas de crecimiento. Las plantas cultivadas en el tratamiento suelo presentaron mayor número de tallos. En este tratamiento los tallos florales también presentaron un mayor número de nudos y de hojas; sin embargo, fueron más cortos. Así mismo, presentaron menor diámetro de tallo y menor longitud y diámetro del botón floral; características determinantes de la calidad. Por tanto, la producción de tallos exportables de grado "select" fue significativamente inferior en el tratamiento suelo, en comparación con los demás tratamientos.O cultivo de cravo no planalto de Bogotá tem sido importante, visto que representa, na atualidade, o segundo lugar nas exportações colombianas de flores de corte. Recentemente, sua produção em sistemas de cultivo em substrato tem aumentado em consequência de fatores sanitários. O objetivo deste estudo foi avaliar o desenvolvimento do cravo tipo estandar cv. Nelson, estabelecido em substratos e em solo, na segunda

  12. Conservative diffusions: a constructive approach to Nelson's stochastic mechanics

    International Nuclear Information System (INIS)

    Carlen, E.A.

    1984-01-01

    In Nelson's stochastic mechanics, quantum phenomena are described in terms of diffusions instead of wave functions; this thesis is a study of that description. Concern here is with the possibility of describing, as opposed to explaining, quantum phenomena in terms of diffusions. In this direction, the following questions arise: ''Do the diffusion of stochastic mechanics - which are formally given by stochastic differential equations with extremely singular coefficients - really exist.'' Given that they exist, one can ask, ''Do these diffusions have physically reasonable paths to study the behavior of physical systems.'' These are the questions treated in this thesis. In Chapter 1, stochastic mechanics and diffusion theory are reviewed, using the Guerra-Morato variational principle to establish the connection with the Schroedinger equation. Chapter II settles the first of the questions raised above. Using PDE methods, the diffusions of stochastic mechanics are constructed. The result is sufficiently general to be of independent mathematical interest. In Chapter III, potential scattering in stochastic mechanics is treated and direct probabilistic methods of studying quantum scattering problems are discussed. The results provide a solid YES in answer to the second question raised above

  13. Increase in fault ride through capability of direct drive permanent magnet based wind farm using VSC-HVDC

    International Nuclear Information System (INIS)

    Maleki, Hesamaldin; Ramachandaramurthy, V K; Lak, Moein

    2013-01-01

    Burning of fossil fuels and green house gasses causes global warming. This has led to governments to explore the use of green energies instead of fossil fuels. The availability of wind has made wind technology a viable alternative for generating electrical power. Hence, many parts of the world, especially Europe are experiencing a growth in wind farms. However, by increasing the number of wind farms connected to the grid, power quality and voltage stability of grid becomes a matter of concern. In this paper, VSC-HVDC control strategy which enables the wind farm to ride-through faults and regulate voltage for fault types is proposed. The results show that the wind turbine output voltage fulfills the E.ON grid code requirements, when subjected to three phase to ground fault. Hence, continues operation of the wind farm is achieved.

  14. Increase in fault ride through capability of direct drive permanent magnet based wind farm using VSC-HVDC

    Science.gov (United States)

    Maleki, Hesamaldin; Ramachandaramurthy, V. K.; Lak, Moein

    2013-06-01

    Burning of fossil fuels and green house gasses causes global warming. This has led to governments to explore the use of green energies instead of fossil fuels. The availability of wind has made wind technology a viable alternative for generating electrical power. Hence, many parts of the world, especially Europe are experiencing a growth in wind farms. However, by increasing the number of wind farms connected to the grid, power quality and voltage stability of grid becomes a matter of concern. In this paper, VSC-HVDC control strategy which enables the wind farm to ride-through faults and regulate voltage for fault types is proposed. The results show that the wind turbine output voltage fulfills the E.ON grid code requirements, when subjected to three phase to ground fault. Hence, continues operation of the wind farm is achieved.

  15. Evaluation of Management of Water Releases for Painted Rocks Rexervoir, Bitterroot River, Montana, 1985 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Lere, Mark E. (Montana Department of Fish, Wildlife and Parks, Missoula, MT)

    1985-12-01

    The Bitterroot River, located in western Montana, is an important and heavily used resource, providing water for agriculture and a source for diversified forms of recreation. Water shortages in the river, however, have been a persistent problem for both irrigators and recreational users. Five major diversions and numerous smaller canals remove substantial quantities of water from the river during the irrigation season. Historically, the river has been severely dewatered between the towns of Hamilton and Stevensville as a result of these withdrawals. Demands for irrigation water from the Bitterroot River have often conflicted with the instream flow needs for trout. Withdrawals of water can decrease suitable depths, velocities, substrates and cover utilized by trout (Stalnaker and Arnette 1976, Wesche 1976). Losses in habitat associated with dewatering have been shown to diminish the carrying capacities for trout populations (Nelson 1980). Additionally, dewatering of the Bitterroot River has forced irrigators to dike or channelize the streambed to obtain needed flows. These alterations reduce aquatic habitat and degrade channel stability. Odell (personal communication) found a substantial reduction in the total biomass of aquatic insects within a section of the Bitterroot River that had been bulldozed for irrigation purposes. The Montana Department of Fish, Wildlife and Parks (MDFWP) has submitted a proposal to the Northwest Power Planning Council for the purchase of 10,000 acre-feet (AF) of stored water in Painted Rocks Reservoir to augment low summer flows in the Bitterroot River. This supplemental water potentially would enhance the fishery in the river and reduce degradation of the channel due to diversion activities. The present study was undertaken to: (1) develop an implementable water management plan for supplemental releases from Painted Rocks Reservoir which would provide optimum benefits to the river: (2) gather fisheries and habitat information to

  16. Fome, eugenia e constituição do campo da nutrição em Pernambuco: uma análise de Gilberto Freyre, Josué de Castro e Nelson Chaves Starvation, eugenics and the development of nutrition in Pernambuco according to Gilberto Freire's, Josué de Castro's and Nelson Chaves' analyses

    Directory of Open Access Journals (Sweden)

    Francisco de Assis Guedes de Vasconcelos

    2001-08-01

    Full Text Available O objetivo deste artigo é examinar a contribuição dos estudos de Gilberto Freyre, Josué de Castro e Nelson Chaves, produzidos nas décadas de 1930 e 1940, para o processo de constituição do campo da nutrição em Pernambuco. O estudo procura demonstrar que as temáticas fome e eugenia constituem as categorias centrais que expressam os pontos de tensão e de comunhão das abordagens desses autores pernambucanos, pelo estatuto científico nesse campo do conhecimento.The purpose of this article is to examine the contribution of the studies Gilberto Freyre, Josué de Castro and Nelson Chaves produced for the development of the Pernambuco nutrition field, from 1930 to 1940. The article attempts to demonstrate that both subjects - starvation and eugenics - are the central categories that express tension and communion in these three authors' approaches to this field of knowledge.

  17. Death of Nelson Mandela: CERN and its Staff Association in history

    CERN Multimedia

    Staff Association

    2013-01-01

    Shortly after the conviction of Nelson Mandela at the Rivonia trial in 1964, the Anti-Apartheid Movement of Geneva was created at a meeting at CERN. Arriving at CERN as Visiting Scientist in June 1966, I joined the Anti-Apartheid Movement immediately. We multiplied the initiatives at CERN and outside of CERN until the release of Mandela with citizens of Geneva, but also with "citizens of the world", who ignored the ban on political activity, particularly for international civil servants. The Anti-Apartheid Movement of Geneva soon became the Anti-Apartheid Movement of Switzerland. It was also the first Anti-Apartheid Movement outside of South Africa. CERN today is honoured to have brought it to the baptismal font thanks to the initiative of several colleagues, including Mike Pentz, president of the CERN staff Association for two years (1961  1963) and also a refugee from South Africa in Europe. Conclusion: well-targeted disobedience can advance humanity. Jean-Pierre Lagnaux, former vis...

  18. The Use of Titrimetric, Nelson Somogyi and Hplc Methods for the Analysis of Cashew Apple Juice Fermentation Broths

    OpenAIRE

    Kantasubrata, Julia; T. Karossi, A; S. Pramudi, A

    1993-01-01

    In cashew apple juice fermentation to produce wine and vinegar, analysis of organic acids and sugars in fermentation broths is very important, due to the fact that optimum conditions of fermentation could only be established from results obtained on monitoring the concentrations of those components during the fermentation process. Analysis of organic acids by tiirimetric method and analysis of sugars by Nelson-Somogyi method only give a total amount of acids and sugars. HPLC is one of the pro...

  19. Análise crítica da metáfora no discurso inaugural de Nelson Mandela

    OpenAIRE

    Candia, Guilene Detimermane de Souza

    2009-01-01

    Esta dissertação de mestrado refere-se à pesquisa, sob a perspectiva crítica e pragmática, das metáforas conceptuais e lingüísticas que tenham o sentido de portadora de ideologia e de estratégia de polidez num discurso político. Teve como base de estudo o Discurso Inaugural do líder sul-africano, Nelson Rolihlahla Mandela, proferido na ocasião de sua posse como presidente da África do Sul, em 10 de maio de 1994, na cidade de Johannesburgo, capital daquele país. O discurso fo...

  20. The economic impacts of a submarine HVDC interconnection between Norway and Great Britain

    International Nuclear Information System (INIS)

    Doorman, Gerard L.; Frøystad, Dag Martin

    2013-01-01

    In the present paper we analyze the profitability of different HVDC interconnection alternatives between Norway and Great Britain for present and future scenarios. The analysis is done from a merchant and a social welfare perspective. The analyses include interconnections between Norway and Scotland and Southern Great Britain, respectively, as well as an alternative link to a future offshore wind farm. From a social welfare perspective the northern interconnection alternative is profitable under all sets of assumptions. The southern alternative is profitable under present conditions, but less than the northern alternative. The alternative link to the offshore wind park is not profitable, but this result is highly dependent on market conditions. From a merchant perspective none of the alternatives is profitable, clearly illustrating that leaving investments to commercial parties does not realize all projects that increase social welfare. - Highlights: • Profitability of interconnection between Norway and GB is analyzed using simulation. • The Northern alternative increases social welfare under all assumptions. • None of the alternatives is profitable from a merchant perspective. • A link to a prospective wind farm 200 km from the GB coast is not profitable. • Social welfare increasing infrastructure may not be built on commercial conditions

  1. "A eloqüência farfalhante da tribuna do júri": o tribunal popular e a lei em Nelson Hungria "A eloqüência farfalhante da tribuna do júri": the people's court and the law in Nelson Hungria

    Directory of Open Access Journals (Sweden)

    Ricardo Sontag

    2009-01-01

    Full Text Available Este artigo pretende analisar a questão do júri no pensamento do penalista Nelson Hungria levando em consideração o contexto histórico das transformações sofridas pelas instituições penais durante o Estado Novo (particularmente as leis sobre o júri e os códigos penal e de processo penal de 1940 e 1941 respectivamente, até o post scriptum do percurso com as modificações trazidas pela Constituição de 1946 e pela lei 268 de 1947 e os seus escritos mais tardios. O aspecto chave a ser considerado nesse percurso é a (indistinção no uso por parte de Hungria dos argumentos do tecnicismo jurídico-penal em relação àqueles do positivismo criminológico dependendo do contexto histórico.This article aims to explore the issue of the jury in Nelson Hungria's thought considering the historical context of the transformations suffered by the criminal law institutions during the "Estado Novo" (particularly the laws on the jury and the criminal code - 1940 - and criminal procedure code - 1941 to the post scriptum of the process with the changes brought by the Constitution of 1946 and the law 268 of 1947 and his later writings. The key aspect to be considered in this process is the (indistinction used by Hungria of the arguments of the criminal-legal technicism in relation to those of criminological positivism depending on historical context.

  2. Insulation Coordination of Arcing Horns on HVDC Electrode Lines: Protection Performance Evaluation, Influence Factors and Improvement Method

    Directory of Open Access Journals (Sweden)

    Xiandong Li

    2018-02-01

    Full Text Available Arcing horns are widely used in high voltage overhead lines to protect insulator strings from being destroyed by the free burning arcs caused by lightening faults. In this paper, we focus on the insulation coordination of arcing horns on the electrode lines of a 5000 MW, ±800 kV high voltage direct current (HVDC system. The protection performance of arcing horns are determined by the characteristics of not only the external system but also the fault arc. Therefore, the behaviors and characteristics of long free burning arcs are investigated by the experiments at first. In order to evaluate the protection performance of arcing horns, the static stability criterion U-I characteristic method is introduced. The influence factors on the protection performance of arcing horns are analyzed theoretically. Finally, the improvement methods for the protection performance of arcing horns are proposed, and the diversified configuration strategy of arcing horns is recommended for cost saving.

  3. The Weathered Corrugations of His Face: A Performative Reflection on Nelson Mandela, Self, and the Call for Racial (UnBecoming

    Directory of Open Access Journals (Sweden)

    Paul Badenhorst

    2015-03-01

    Full Text Available On the occasion of the first anniversary of the death of Nelson Rolihlahla MANDELA, this self-exploratory narrative study utilizes a Butlerian performative theoretical framework to both uncover discursively regulated social practices as generative of raced identity ensconced in belonging, and the undoing of such identity through the redeployment of social practices predicated instead on a Weltanschauung of becoming. While the accountable subject of autoethnographic work is concomitantly problematized, fluid subjectivity is itself demonstrated as crucial to historical accountability. A resultant appeal for white South Africans to actively begin the work of defamiliarizing themselves with the sanitized dominant popular culture representation of the peace icon, this research ultimately calls for new existential reflection upon the face of Nelson MANDELA so as to begin uncovering its deeper historical significance, contemporary relevance, and the future ethical imperative it demands of those who come from a liminal position of, as J.M. COETZEE once wrote, "no longer European, not yet African" (1988, p.11. In short, it is argued that white South Africans need to move from a condition of belonging predicated on raced identity to one of transracial—and even interracial—African becoming. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs150223

  4. Nelson Mandela’s ‘Ordinary Love’ Addressed in Pop-rock Music: a Long Song of Freedom

    Directory of Open Access Journals (Sweden)

    Simona Martini

    2014-11-01

    Full Text Available This paper aims to highlight how inspirational the figure of Nelson Mandela has been for several musicians and songwriters. In particular, it focuses on songs written by Western musicians from the early Eighties until 2013 – all showing the extent to which the South African leader has epitomized the struggle for equality and freedom. This study points out how the success of a hit single in 1984 – British ska group The Special AKA’s “Free Nelson Mandela” – paved the way for a quick increase in the number of musicians who got involved in the anti-apartheid movement and contributed to make Western audiences know about Mandela and increasingly demand that apartheid be put to an end. This survey seeks to examine the main achievements in pop-rock songs that generated both from the growing awareness about the South African leader’s experience when he was imprisoned, and the legacy of his exemplum after he was set free. Among the songs cited: Simple Minds’ “Mandela Day”, the various artists’ tribute “46664” and the most recent Golden Globe-awarded “Ordinary Love” by U2, written for the soundtrack of the biopic The Long Walk to Freedom. To better understand how the figure of Mandela has been addressed in these works, the paper includes analyses of the most complex and significant lyrics among the songs discussed, thus also showing how the South African cultural background as it was received by the West could have informed the songwriting, and how the Western reception of such songs determined an increasing awareness about Mandela’s plight and the whole phenomenon of apartheid.

  5. The Anticancer Activity of Sea Buckthorn [Elaeagnus rhamnoides (L. A. Nelson

    Directory of Open Access Journals (Sweden)

    Beata Olas

    2018-03-01

    Full Text Available Various parts of sea buckthorn [Elaeagnus rhamnoides (L. A. Nelson], particularly the berries, known also as seaberries, or Siberian pineapples, are characterized by a unique composition of bioactive compounds: phenolic compounds, vitamins (especially vitamin C, unsaturated fatty acids, and phytosterols such as beta-sitosterol. These berries, together with the juices, jams, and oils made from them, have a range of beneficial antioxidant, anti-inflammatory, and anticancer effects. This short review discusses whether sea buckthorn may represent a “golden mean” for the treatment of cancers: It has anti-proliferation properties and can induce apoptosis and stimulate the immune system, and sea buckthorn oil counteracts many side effects of chemotherapy by restoring kidney and liver function, increasing appetite, and keeping patients in general good health. Although the anticancer activity of sea buckthorn has been confirmed by many in vitro and animal in vivo studies, the treatment and prophylactic doses for humans are unknown. Therefore, greater attention should be paid to the development of well-controlled and high-quality clinical experiments in this area.

  6. Incentives for HIV testing at the workplace in the automotive industry in the Nelson Mandela Bay Municipality: Ethical considerations

    Directory of Open Access Journals (Sweden)

    Martin Weihs

    2017-07-01

    Full Text Available Comprehensive HIV and AIDS workplace programmes made use of substantial lottery incentives in HIV counselling and testing drives to promote HIV testing at four companies in the automotive industry in the Nelson Mandela Bay Municipality. The main aim was to use lottery incentives to increase uptake for HIV testing. This would help to define company HIV prevalence and ensure timely support, care and treatment of employees. In total, 1 324 employees, making up about 90% of the total staff, were tested for HIV in the four companies during wellness testing days. In order to gain an understanding of employees’ experiences of the lotteries as part of the HIV counselling and testing drive, quantitative data were collected among a total of 414 employees, and 17 interviews were conducted in the four companies. In this article, we investigate the issue of whether the lotteries unduly influenced the employees’ participation in workplace HIV testing, and an approach to resolving an identified ethical dilemma is presented. The ethical question as to whether lottery incentives contribute to undue coercion was explored using both a utilitarian and a deontological approach. The analysis concluded that the use of lotteries to encourage HIV testing in the workplaces of the automotive industry in the Nelson Mandela Bay Municipality can be deemed morally acceptable.

  7. Incentives for HIV testing at the workplace in the automotive industry in the Nelson Mandela Bay Municipality: Ethical considerations

    Directory of Open Access Journals (Sweden)

    Martin Weihs

    2017-07-01

    Full Text Available Comprehensive HIV and AIDS workplace programmes made use of substantial lottery incentives in HIV counselling and testing drives to promote HIV testing at four companies in the automotive industry in the Nelson Mandela Bay Municipality. The main aim was to use lottery incentives to increase uptake for HIV testing. This would help to define company HIV prevalence and ensure timely support, care and treatment of employees. In total, 1 324 employees, making up about 90% of the total staff, were tested for HIV in the four companies during wellness testing days. In order to gain an understanding of employees’ experiences of the lotteries as part of the HIV counselling and testing drive, quantitative data were collected among a total of 414 employees, and 17 interviews were conducted in the four companies. In this article, we investigate the issue of whether the lotteries unduly influenced the employees’ participation in workplace HIV testing, and an approach to resolving an identified ethical dilemma is presented. The ethical question as to whether lottery incentives contribute to undue coercion was explored using both a utilitarian and a deontological approach. The analysis concluded that the use of lotteries to encourage HIV testing in the workplaces of the automotive industry in the Nelson Mandela Bay Municipality can be deemed morally acceptable.

  8. Coulomb Scattering in the Massless Nelson Model III: Ground State Wave Functions and Non-commutative Recurrence Relations

    Science.gov (United States)

    Dybalski, Wojciech; Pizzo, Alessandro

    2018-02-01

    Let $H_{P,\\sigma}$ be the single-electron fiber Hamiltonians of the massless Nelson model at total momentum $P$ and infrared cut-off $\\sigma>0$. We establish detailed regularity properties of the corresponding $n$-particle ground state wave functions $f^n_{P,\\sigma}$ as functions of $P$ and $\\sigma$. In particular, we show that \\[ |\\partial_{P^j}f^{n}_{P,\\sigma}(k_1,\\ldots, k_n)|, \\ \\ |\\partial_{P^j} \\partial_{P^{j'}} f^{n}_{P,\\sigma}(k_1,\\ldots, k_n)| \\leq \\frac{1}{\\sqrt{n!}} \\frac{(c\\lambda_0)^n}{\\sigma^{\\delta_{\\lambda_0}}} \\prod_{i=1}^n\\frac{ \\chi_{[\\sigma,\\kappa)}(k_i)}{|k_i|^{3/2}}, \\] where $c$ is a numerical constant, $\\lambda_0\\mapsto \\delta_{\\lambda_0}$ is a positive function of the maximal admissible coupling constant which satisfies $\\lim_{\\lambda_0\\to 0}\\delta_{\\lambda_0}=0$ and $\\chi_{[\\sigma,\\kappa)}$ is the (approximate) characteristic function of the energy region between the infrared cut-off $\\sigma$ and the ultraviolet cut-off $\\kappa$. While the analysis of the first derivative is relatively straightforward, the second derivative requires a new strategy. By solving a non-commutative recurrence relation we derive a novel formula for $f^n_{P,\\sigma}$ with improved infrared properties. In this representation $\\partial_{P^{j'}}\\partial_{P^{j}}f^n_{P,\\sigma}$ is amenable to sharp estimates obtained by iterative analytic perturbation theory in part II of this series of papers. The bounds stated above are instrumental for scattering theory of two electrons in the Nelson model, as explained in part I of this series.

  9. Evolution of the ICESIM model

    International Nuclear Information System (INIS)

    Carson, R.W.; Groeneveld, J.L.

    1997-01-01

    A computer model named ICESIM was developed by Acres International in 1973 to study river ice problems associated with the construction of the Limestone Hydroelectric Generating Station on the Nelson River. The program could numerically simulate the processes of river ice formation under steady state conditions of flow. The program has evolved over two decades and has been used as a design and analytical tool for several river ice problems. One of the shortcomings of the model was its inability to consider varying river flows during a simulation. The model has recently been restructured into a new version called ICEDYN which uses a hydrodynamic module to compute river hydraulics. The ICEDYN program uses the same approach as ICESIM, but river hydraulics, which are affected by changes in inflow, and the accumulation of ice, are computed through a hydrodynamic solution of the St. Venant Equations. The ICEDYN model requires an extensive data set to describe the particular river reach being simulated. It has been tested on the Nelson River in northern Manitoba to see whether the numerical methods in the model can successfully represent field conditions. Results were encouraging but additional refinement is still needed. 7 refs., 1 tab., 7 figs

  10. The proposed Nelson Mandela Children's Hospital, Johannesburg: providing the best care for children in the developing world.

    Science.gov (United States)

    Bolton, Keith

    2011-01-01

    Construction will soon commence on the Nelson Mandela Children's Hospital (NMCH) in Johannesburg, South Africa. The Hospital will have 250-300 beds and will provide tertiary and quaternary care to children in specific Centers of Excellence. Admission to this referral facility will be based entirely on medical needs. The disciplines that are catered for include Paediatric surgery, oncology, nephrology, cardiology, intensive care and imaging. The NMCH will be South Africa's first "Private Hospital - Not for Gain". Funding for capital expenditure is currently being raised by the Trust. Operational expenditure will come from the Department of Health, private insurers and neighbouring governments.

  11. Integration of power flow controlling devices and HVDC-systems into the optimal power flow; Integration von leistungsflusssteuernden Komponenten und HGUe-Systemen in die Leistungsflussoptimierung

    Energy Technology Data Exchange (ETDEWEB)

    Natemeyer, Hendrik; Scheufen, Martin; Roehder, Andreas; Schnettler, Armin [RWTH Aachen Univ. (Germany). Inst. fuer Hochspannungstechnik (IFHT)

    2012-07-01

    An integration of High Voltage Direct Current Transmission Systems (HVDC) or Flexible AC Transmission Systems (FACTS) into power systems enables the possibility to actively influence and control the corresponding power flows in the electrical network. The systemic benefits are a more efficient utilization of existing transmission capacities and improved controllability in fault situations. This paper introduces methods of a coordinative control of such devices and their representation in stationary power flow calculations including the control in (n-1)-cases. This might be a useful tool for the network operation, especially in face of more frequently occurring fast system changes. Examples of a corresponding implementation and application are provided. (orig.)

  12. The Honorable William Nelson, Senior Senator from Florida, Chairman, Senate Committee on Space, Aeronautics and Related Sciences visiting the AMS Hall of Prevessin with Prof. Samuel Ting from the MIT.

    CERN Multimedia

    Maximilien Brice

    2008-01-01

    The Honorable William Nelson, Senior Senator from Florida, Chairman, Senate Committee on Space, Aeronautics and Related Sciences visiting the AMS Hall of Prevessin with Prof. Samuel Ting from the MIT.

  13. Economic benefit evaluation for renewable energy transmitted by HVDC based on production simulation (PS) and analytic hierarchy process(AHP)

    Science.gov (United States)

    Zhang, Jinfang; Zheng, Kuan; Liu, Jun; Huang, Xinting

    2018-02-01

    In order to support North and West China’s RE (RE) development and enhance accommodation in reasonable high level, HVDC’s traditional operation curves need some change to follow the output characteristic of RE, which helps to shrink curtailment electricity and curtailment ratio of RE. In this paper, an economic benefit analysis method based on production simulation (PS) and Analytic hierarchy process (AHP) has been proposed. PS is the basic tool to analyze chosen power system operation situation, and AHP method could give a suitable comparison result among many candidate schemes. Based on four different transmission curve combinations, related economic benefit has been evaluated by PS and AHP. The results and related index have shown the efficiency of suggested method, and finally it has been validated that HVDC operation curve in following RE output mode could have benefit in decreasing RE curtailment level and improving economic operation.

  14. Development and Evaluation of cooperative control system for an HVDC transmission system connected with an isolated BWR power plant

    International Nuclear Information System (INIS)

    Horiuchi, Susumu; Hara, Tsukusi; Matori, Iwao; Hirayama, Kaiichirou.

    1987-01-01

    In the cooperative control system developed for an HVDC transmission system connected with an isolated BWR power plant, the equilibrium state between power plant output and DC transmission power is examined by way of the detection of the generator frequency. And, thereby start-up and shutdown of the DC system and controlling of the transmission power are made, so that the signal transmission with the power plant becomes unnecessary, enabling the easy cooperative operation. In order to investigate validity of this control system, various digital simulation and simulator test with the control system were carried out. In this way, behavior of the power plant and stability of the DC transmission system were evaluated in the connection to the DC system at power plant start-up, follow of the transmission power in change of the power plant output and in various system failures. (Mori, K.)

  15. Radiocarbon dates from the holocene levels at Nelson Bay Cave, and an interim report on their associations

    International Nuclear Information System (INIS)

    Inskeep, R.R.; Vogel, J.C.

    1985-01-01

    Various changes in the cultural material derived from the later Holocene levels of Nelson Bay Cave can be pinpointed in temporal context by means of a large series of radiocarbon dates, such as Carbon 13 and Carbon 14 covering the past 6 000 years. As excavations and analysis of the recovered materials proceeded, radiocarbon dates were sought in order to provide a chronological frame work for what are taken to be significant features in the history of the site, and these are discussed in the article. Several pottery and assumed sheep remains were recorded. Six human burials were also recovered and this helps with the characterization of Holocene burial practices

  16. Late Otiran sedimentation and glacial chronology in the Warwick valley, southeast Nelson

    International Nuclear Information System (INIS)

    Mabin, M.C.G.

    1983-01-01

    Approximately 14 m of sediment are exposed in a road cutting beneath a landslide deposit in the Warwick valley, southeast Nelson, New Zealand. Three radiocarbon dates and 5 pollen spectra were obtained from organic horizons in these sediments. The dates indicate that lacustrine sedimentation predominated from before 17 500 until 14 450 years ago. This was interrupted by a brief period of gravel aggradation between 17 500 and 16 650 years ago, which is attributed to a glacial advance. Vegetation at the site was consistently dominated by Cyperaceae, with some Gramineae, suggesting a bleak, treeless landscape. Correlation of this information with other radiocarbon dated sites indicates the need for some revision of the chronology of the late Otira Glaciation. A late phase of the Kumara 2 2 advance occurred between 17 000 and 16 000 years ago, and the Kumara 3 1 advance did not occur until after about 15 000 years ago. The end of the Otira Glaciation probably occurred between 13 000 and 12 500 years ago. (auth)

  17. Late Otiran sedimentation and glacial chronology in the Warwick valley, southeast Nelson

    Energy Technology Data Exchange (ETDEWEB)

    Mabin, M C.G. [Canterbury Univ., Christchurch (New Zealand). Dept. of Geology

    1983-01-01

    Approximately 14 m of sediment are exposed in a road cutting beneath a landslide deposit in the Warwick valley, southeast Nelson, New Zealand. Three radiocarbon dates and 5 pollen spectra were obtained from organic horizons in these sediments. The dates indicate that lacustrine sedimentation predominated from before 17,500 until 14,450 years ago. This was interrupted by a brief period of gravel aggradation between 17,500 and 16,650 years ago, which is attributed to a glacial advance. Vegetation at the site was consistently dominated by Cyperaceae, with some Gramineae, suggesting a bleak, treeless landscape. Correlation of this information with other radiocarbon dated sites indicates the need for some revision of the chronology of the late Otira Glaciation. A late phase of the Kumara 2/sub 2/ advance occurred between 17,000 and 16,000 years ago, and the Kumara 3/sub 1/ advance did not occur until after about 15,000 years ago. The end of the Otira Glaciation probably occurred between 13,000 and 12,500 years ago.

  18. Recent advances in numerical solution of ionized fields associated with unipolar HVDC transmission lines in the presence of wind

    International Nuclear Information System (INIS)

    Li, X.; Raghuveer, M.R.; Ciric, I.R.

    1997-01-01

    Three finite element numerical algorithms were developed for solving the ionized field of unipolar HVDC transmission lines in the presence of wind. The solution of the ionized field was derived by transforming the boundary value problem to an optimization problem. The Gaussian iterative method was used for all three algorithms. The main features of each algorithm were presented and compared. The advantage of the first algorithm is that there is no need to assume the space charge density to be uniform on the conductor surface and therefore it is flexible in dealing with a complicated geometry like that of a bundled conductor. The main features of the other two algorithms were their ability to perform better with increase in wind velocity. Algorithm No. 2 was better than algorithm No. 1 in terms of storage and computational time. Algorithm No. 3 also had the advantage of using a triangular fine volume method which allowed computations to proceed faster. 11 refs., 10 figs

  19. Control and operation of wind turbine converters during faults in an offshore wind power plant grid with VSC-HVDC connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Teodorescu, Remus; Rodriguez, Pedro

    2011-01-01

    Voltage source converter (VSC) based high voltage dc (HVDC) transmission is an attractive technique for large offshore wind power plants, especially when long cable transmission is required for connection to the onshore grid. New multi-MW wind turbines are likely to be equipped with full scale...... converters to meet the stringent grid code requirements. In such a scenario, the offshore grid is terminated to the power electronic converters on all the ends. This paper presents a control scheme for the synchronization and control of the grid side converters (GSC) of the wind turbine generators (WTG......). Current limit control enables the GSC to sustain the fault currents during short circuits in the offshore wind collector system grid. However, power transmission is affected, and the fault has to be isolated. It can be resynchronized after the fault has been cleared and the breaker reclosed. Healthy WTG...

  20. p-hacking by post hoc selection with multiple opportunities: Detectability by skewness test?: Comment on Simonsohn, Nelson, and Simmons (2014).

    Science.gov (United States)

    Ulrich, Rolf; Miller, Jeff

    2015-12-01

    Simonsohn, Nelson, and Simmons (2014) have suggested a novel test to detect p-hacking in research, that is, when researchers report excessive rates of "significant effects" that are truly false positives. Although this test is very useful for identifying true effects in some cases, it fails to identify false positives in several situations when researchers conduct multiple statistical tests (e.g., reporting the most significant result). In these cases, p-curves are right-skewed, thereby mimicking the existence of real effects even if no effect is actually present. (c) 2015 APA, all rights reserved).

  1. O MASOQUISMO MORAL NO “TEATRO DESAGRADÁVEL” DE NELSON RODRIGUES: APORTES PSICANALÍTICOS

    Directory of Open Access Journals (Sweden)

    Meury Gardênia Lima de Araújo

    2015-06-01

    Full Text Available Pretende-se desenvolver neste trabalho a psicanálise em extensão, com um delineamento investigativo sobre as obras teatrais míticas Anjo Negro e Dorotéia de Nelson Rodrigues, recorrendo-se ao que formula Freud sobre o conceito de masoquismo moral. Almeja-se, através de estudo bibliográfico, buscar e fazer interagir psicanálise e literatura, notando a coexistência na arte dos “mistérios” inconscientes do sujeito dividido, fictício em questão, “traduzidos” da vida real, primando pela criatividade e como ela expressa tão naturalmente o produto inconsciente. Expõe-se, por fim, as abordagens literárias pelo viés psicanalítico para apresentar suas contribuições ao legado freudiano, exibindo trechos das peças “Anjo Negro” e “Dorotéia” a fim de norteá-las estruturalmente. 

  2. True Grit: In Tracking down the Real Story of a Legendary Hero of the Old West, Vaunda Micheaux Nelson also Nabbed the Coretta Scott King Award

    Science.gov (United States)

    Fleishhacker, Joy

    2010-01-01

    When Vaunda Micheaux Nelson donned a black Stetson to become the biographer of Deputy U.S. Marshal Bass Reeves, she had no idea that her square-shooting book about an unsung African-American hero of the Old West would win over a posse of fans and earn her the prestigious 2010 Coretta Scott King (CSK) Author Award. "Bad News for Outlaws"…

  3. Custeio dos gastos no serviço público de saúde: estudo de caso no Hospital Nelson Salles

    OpenAIRE

    Warley Francisco de Araújo Pereira

    2014-01-01

    A dissertação tem como objetivo aplicar um método de custeio aos gastos atribuídos, pelo Hospital Nelson Salles, na execução do serviço público de saúde, em apoio ao Município Engenheiro Paulo de Frontin. Para a realização deste trabalho, o estudo utilizou-se da pesquisa bibliográfica para fundamentar e ilustrar o tema proposto, bem como, do método exploratório descritivo para reconhecer a situação da instituição e identificar uma metodologia de controle dos custos adequada à realidade da org...

  4. A poética da esperança: sentidos políticos nas memórias de Nelson Mandela

    OpenAIRE

    Silva, Cristiane Mare da

    2016-01-01

    O estudo que ora apresento desenvolveu-se no Programa de Pós-Graduação em História, da Pontifícia Universidade Católica de São Paulo e tem por objeto textos biográficos e autobiográficos do sul africano Nelson Mandela, que nos permitem apreender momentos e enunciados, orientadores da luta pela igualdade, do exercício da tolerância e a defesa dos direitos humanos, não apenas na África do Sul, mas por toda parte onde existam conflitos raciais e coloniais inerentes à enxpansão do Hemisfério Ocid...

  5. Plaadid / Valner Valme

    Index Scriptorium Estoniae

    Valme, Valner, 1970-

    2003-01-01

    Uutest plaatidest Smashing Pumpkins "Earphoria", "Jazzland Remixed 2", Ekrem & Gypsy Groovz "Rivers Of Happiness", Trio Tesis "Los Pasos Perdidos", Willie Nelson & Friends "Stars & Guitars", Victor Davies "Remixes", Velikije Luki "Tallinn põleb!", Mario Frangoulis "Sometimes I Dream"

  6. The Tibagi river and representations: a water controversy and development of Tibagi Project(1970 - 2000

    Directory of Open Access Journals (Sweden)

    Eliane Aparecida Biasetto

    2014-12-01

    Full Text Available The river Tibagi from the city of Londrina, in the years 1970 and 1980 was a subject of much discussion and controversy due to the project of raising its waters to supply the population of the cities of Londrina and region. In articles published in newspapers, especially in the Folha de Londrina, in the 1970s and 1980s, it was identified that, this time, the perception emerged that the river was polluted. Thus, our primary goal in the first part of this research is to investigate how it came to creating this image. Therefore, we used a collection of newspaper clippings about the controversy raised from the waters Tibagi and interviews with Nelson Amanthea civil engineer and agronomist Marcos Antonio Castanheira, both participated in discussions on the project. It was in this period that the ideas of ecology was entered and began to circulate in the city in the late 1970s. In this context, the emergence of the "age of ecology”, allegations and actions to combat pollution started to become more effective and broad, as well as, arose environmental associations, specialized government agencies and specific legislation. Thus, the objective of this research is also investigating the involvement of scientists and institutions in environmental issues through research of river Tibagi that became evident in the late 1980 and early next decade when the University State of Londrina initiated research in Tibagi river basin. Is emphasized the participation of members of the Department of Animal Biology and Plant - UEL, the company Klabin Pulp and Paper, Telêmaco Borba - PR and COPATI - Intermunicipal Consortium of Tibagi Basin, projects and actions in order to promote their recovery. A major action was investigated Project “Appearance of  Fauna and Flora River Tibagi” which became known as “Project Tibagi “. In this sense sought to investigate the origins of the project, the main participants involved, their development, search results, the

  7. Direct current power delivery system and method

    Science.gov (United States)

    Zhang, Di; Garces, Luis Jose; Dai, Jian; Lai, Rixin

    2016-09-06

    A power transmission system includes a first unit for carrying out the steps of receiving high voltage direct current (HVDC) power from an HVDC power line, generating an alternating current (AC) component indicative of a status of the first unit, and adding the AC component to the HVDC power line. Further, the power transmission system includes a second unit for carrying out the steps of generating a direct current (DC) voltage to transfer the HVDC power on the HVDC power line, wherein the HVDC power line is coupled between the first unit and the second unit, detecting a presence or an absence of the added AC component in the HVDC power line, and determining the status of the first unit based on the added AC component.

  8. 75 FR 10229 - Application for Presidential Permit; Champlain Hudson Power Express, Inc.

    Science.gov (United States)

    2010-03-05

    ... current (HVDC) electric transmission line that will originate at an HVDC converter station in Quebec... project (the ``Project'') would be a 2,000- megawatt (MW) HVDC Voltage Source Converter (VSC) controllable transmission system, comprising two 1,000-MW HVDC bipoles, each of which would include two submarine or...

  9. Investigation of space charge distribution of low-density polyethylene/GO-GNF (graphene oxide from graphite nanofiber) nanocomposite for HVDC application.

    Science.gov (United States)

    Kim, Yoon Jin; Ha, Son-Tung; Lee, Gun Joo; Nam, Jin Ho; Ryu, Ik Hyun; Nam, Su Hyun; Park, Cheol Min; In, Insik; Kim, Jiwan; Han, Chul Jong

    2013-05-01

    This paper reported a research on space charge distribution in low-density polyethylene (LDPE) nanocomposites with different types of graphene and graphene oxide (GO) at low filler content (0.05 wt%) under high DC electric field. Effect of addition of graphene oxide or graphene, its dispersion in LDPE polymer matrix on the ability to suppress space charge generation will be investigated and compared with MgO/LDPE nanocomposite at the same filler concentration. At an applied electric field of 80 kV/mm, a positive packet-like charge was observed in both neat LDPE, MgO/LDPE, and graphene/LDPE nanocomposites, whereas only little homogenous space charge was observed in GO/LDPE nanocomposites, especially with GO synthesized from graphite nano fiber (GNF) which is only -100 nm in diameter. Our research also suggests that dispersion of graphene oxide particles on the polymer matrix plays a significant role to the performance of nanocomposites on suppressing packet-like space charge. From these results, it is expected that nano-sized GO synthesized from GNF can be a promising filler material to LDPE composite for HVDC applications.

  10. Design and development of high voltage and high frequency center tapped transformer for HVDC test generator

    International Nuclear Information System (INIS)

    Thaker, Urmil; Saurabh Kumar; Amal, S.; Baruah, U.K.; Bhatt, Animesh

    2015-01-01

    A High Voltage center tapped transformer for high frequency application had been designed, fabricated, and tested. It was designed as a part of 200 kV HVDC Test Generator. The High Frequency operation of transformer increases power density. Therefore it is possible to reduce power supply volume. The step up ratio in High Voltage transformer is limited due to stray capacitance and leakage inductance. The limit was overcome by winding multi secondary outputs. Switching frequency of transformer was 15.8 kHz. Input and output voltages of transformer were 270V and 16.5kV-0V-16.5kV respectively. Power rating of transformer is 7kVA. High Voltage transformer with various winding and core arrangement was fabricated to check variation in electrical characteristics. The transformer used a ferrite core (E Type) and nylon insulated primary and secondary bobbins. Two set of E-E geometry cores had been stacked in order to achieve the estimated core volume. Compared with traditional high voltage transformer, this transformer had good thermal behavior, good line insulation properties and a high power density. In this poster, design procedures, development stages and test results of high voltage and high frequency transformer are presented. Results of various parameters such as transformer loss, temperature rise, insulation properties, impedance of primary and secondary winding, and voltage regulation are discussed. (author)

  11. The Honorable William Nelson, Senior Senator from Florida, Chairman, Senate Committee on Space, Aeronautics and Related Sciences signing the golden book. Greeting by Mr Robert Aymar, CERN Director General and Prof. Samuel Ting from the MIT.

    CERN Multimedia

    Maximilien Brice

    2008-01-01

    The Honorable William Nelson, Senior Senator from Florida, Chairman, Senate Committee on Space, Aeronautics and Related Sciences signing the golden book. Greeting by Mr Robert Aymar, CERN Director General and Prof. Samuel Ting from the MIT.

  12. Notes on dissimulation in the theatre of Nelson Rodrigues: the case of O beijo no asfalto

    Directory of Open Access Journals (Sweden)

    Adauto Locatelli Taufer

    2013-12-01

    Full Text Available The paradigms that determine what is true and false are the reason for to investigate aspects that represent the dissimulation in O beijo no asfalto, by Nelson Rodrigues. Starobinski’s investigations, for whom the society is built upon the solid bases of the conventions that determine how to be and how to act in the social complex mesh; Michel Foucault, for whom the limit between falsehood and truth is a dangerous zone, thanks to the multiple facets that cover the lie -, constitute on the theoretical presuppositions that form the base to the analysis inside. Assuming that the mask is a simulacrum, in fact, it acts as if it was a kind of entry and exit portal that we have in order to travel the maze of social relations. The main goal of this article is to point the different social masks used by “rodriguean” characters on the referred work.

  13. A natural ice boom

    Energy Technology Data Exchange (ETDEWEB)

    Hopper, H.R. [Manitoba Hydro, Winnipeg, MB (Canada)

    1998-10-01

    Planning for ice jams and ice movements are critical on the Nelson River in northern Manitoba in designing cofferdams. Experience on the St. Lawrence River demonstrated the possibility of exercising some control over ice action by judicious placement of log booms or ice control structures. The success of experiments with man-made controls led to field tests in which an ice sheet of sufficient magnitude and competence was introduced into the open water stream of the Nelson River. The ice sheet was subsequently jammed in a narrow channel, thereby creating a natural ice bridge or boom upstream of a proposed hydro development. Under favourable conditions, this boom would initiate the progression of the ice cover from its location upstream, cutting off the downstream reach from the ice producing potential of the upstream reach. Although ice would still be generated downstream, the length of the reach between the ice boom and the development site would be short enough that ice jamming at the development site would never occur. Although problems in blasting prevented the introduction of a competent ice sheet into the main stream of the river at the location chosen, sufficient confidence in the theory was gained to warrant further consideration. 4 refs., 1 tab., 10 figs.

  14. AC Transmission Emulation Control Strategies for the BTB VSC HVDC System in the Metropolitan Area of Seoul

    Directory of Open Access Journals (Sweden)

    Sungyoon Song

    2017-08-01

    Full Text Available In the Korean power system, growing power loads have recently created the problems of voltage instability and fault current in the Seoul Capital Area (SCA. Accordingly, the back-to-back (BTB voltage source converter (VSC high-voltage direct-current (HVDC system is emerging to resolve such problems with grid segmentation. However, non-convergence problems occur in this metropolitan area, due to the large change of power flow in some contingencies. Therefore, this paper proposes two kinds of AC transmission emulation control (ATEC strategies to improve the metropolitan transient stability, and to resolve the non-convergence problem. The proposed ATEC strategies are able to mitigate possible overloading of adjacent AC transmission, and maintain power balance between metropolitan regions. The first ATEC strategy uses a monitoring system that permits the reverse power flow of AC transmission, and thus effectively improves the grid stability based on the power transfer equation. The second ATEC strategy emulates AC transmission with DC link capacitors in a permissible DC-link voltage range according to angle difference, and securely improves the gird stability, without requiring grid operator schedule decisions. This paper compares two kinds of ATEC schemes: it demonstrates the first ATEC strategy with specific fault scenario with PSS/E (Power Transmission System Planning Software, and evaluates the second ATEC strategy with internal controller performance with PSCAD/EMTDC (Power System Electromagnetic Transients Simulation Software.

  15. Construção de curva de juros de debêntures no mercado brasileiro utilizando a parametrização de Nelson-Siegel

    Directory of Open Access Journals (Sweden)

    Vinícius Gomes Araújo

    2013-03-01

    Full Text Available O objetivo nesse trabalho é a construção da Estrutura a Termo de Taxa de Juros (ETTJ das debêntures que se encontram disponíveis no mercado brasileiro, usando o modelo Nelson-Siegel (1987. As curvas de juros são divididas de acordo com o tipo de indexador e com a classificação de risco atribuída às debêntures. Por fim, foi possível mensurar o spread que existe entre o mercado de títulos privados (debêntures e os títulos públicos.

  16. Impact of Cyber Attacks on High Voltage DC Transmission Damping Control

    Directory of Open Access Journals (Sweden)

    Rui Fan

    2018-04-01

    Full Text Available Hybrid AC/HVDC (AC-HVDC grids have evolved to become huge cyber-physical systems that are vulnerable to cyber attacks because of the wide attack surface and increasing dependence on intelligent electronic devices, computing resources and communication networks. This paper, for the first time, studies the impact of cyber attacks on HVDC transmission oscillation damping control.Three kinds of cyber attack models are considered: timing attack, replay attack and false data injection attack. Followed by a brief introduction of the HVDC model and conventional oscillation damping control method, the design of three attack models is described in the paper. These attacks are tested on a modified IEEE New England 39-Bus AC-HVDC system. Simulation results have shown that all three kinds of attacks are capable of driving the AC-HVDC system into large oscillations or even unstable conditions.

  17. Aplicación del modelo polinomial en la evaluación de la uniformidad de riego del aspersor autocompensado Nelson R10

    Directory of Open Access Journals (Sweden)

    Fanny del Rocío Rodríguez-Jarama

    2015-01-01

    Full Text Available Los métodos de evaluación de la uniformidad de riego estiman las condiciones hidráulicas de funcionamiento del sistema de riego y su influencia en la aplicación de láminas de agua, con base en las necesidades hídricas de un cultivo. El modelo de evaluación utilizado en la presente investigación fue el polinomial. El ensayo evaluó el funcionamiento del sistema de riego con 4 presiones de operación distintas, medidas a la salida de la válvula del módulo de riego, y por cada presión de operación se tomaron 16 datos de caudales, en 5 módulos de riego instalado con el aspersor autocompensado Nelson R10. Como resultado se obtuvo el coeficiente de uniformidad, el coeficiente de distribución, el área adecuadamente irrigada y el factor de adecuación del riego. Uno de los principales resultados fue la no existencia de diferencia significativa entre las presiones mientras esta se mantengan en el rango de autocompensación; por otro lado, en el coeficiente de distribución sí existen diferencias significativas entre los tratamientos, a pesar de que todos dan valores mayores al 90%, en contraste con los porcentajes del área relativa adecuadamente regada, que no superan el 50% en ninguno de los tratamientos. Con lo anterior se pudo validar y verificar que el aspersor Nelson R10 autocompensado, una vez instalado en campo, cumple con las características técnicas de operación expuestas en el catálogo del fabricante, sin embargo, sí se debe manejar y controlar la lámina de riego aplicada.

  18. 76 FR 79206 - Commercial Renewable Energy Transmission on the Outer Continental Shelf (OCS) Offshore Mid...

    Science.gov (United States)

    2011-12-21

    ...-circuit, high-voltage direct current (HVDC) transmission line that would collect power generated by wind...-voltage alternating current into HVDC using voltage sourced converters. Each offshore converter platform... transmission grid at up to seven locations where AWC terrestrial converter stations would convert the HVDC...

  19. Homosexual Identity in Alex Sanchez's 'Rainbow Trilogy'

    Directory of Open Access Journals (Sweden)

    Nanda Vidyastria

    2017-03-01

    Full Text Available This research aims at describing 1 stages of homosexual identity development in three main characters in the Rainbow Trilogy using Cass model, 2 factors influencing the development of homosexual identity using D Augellis theory, and 3 forms of victimization towards homosexuals experienced by the main characters using theories of D Augelli and Rivers. Queer studies was applied to describe and analyze the data in forms of words, phrases, sentences, statements, dialogues as well as monologues in the Rainbow Trilogy, recording thoughts and actions by the characters in accordance with the research focus. As a result, the research finds out that the three novels describe clearly all stages of Cass model of homosexual identity development in Jason and Kyle, including their identity confusions, comparisons, acceptances, tolerances, prides and syntheses. In Nelson, only one stage that can be identified as Nelson is described as one whose sexual identity has been formed. The research also reveals how factors of personal subjectivity and action, interactive intimacy and sociohistorical connection are connected to each others and also influencing the homosexual identity developments of the main characters. Besides, the research also shows that various kinds of victimization occur to Jason, Kyle and Nelson. Normative victimizations made to feel different are experienced by Nelson and Kyle. Family stressor and prejudices in connection to AIDS are experienced by the three characters. Victimization of direct attacks in forms of verbal and physical abuses are experienced by Kyle and Nelson. Lastly, the research finds out that Nelson is the only character experiencing sexual abuse. It occurs in form of undesired comments oriented to a sexual violence.

  20. O acervo de mosquitos (Diptera, Culicidae de Nelson L. Cerqueira na Coleção de Invertebrados do Instituto Nacional de Pesquisas da Amazônia, Manaus, Brasil The Nelson L. Cerqueira Mosquito Collection (Diptera, Culicidae in the Invertebrate Collection of the Instituto Nacional de Pesquisas da Amazônia, Manaus, Brazil

    Directory of Open Access Journals (Sweden)

    Rosa Sá Gomes Hutchings

    2005-03-01

    Full Text Available Registra-se a descoberta de espécimes de mosquitos que pertenciam a Nelson L. Cerqueira, e estão sendo depositados na coleção de Invertebrados do Instituto Nacional de Pesquisas da Amazônia. A coleção contém 2.046 espécimes adultos e 387 lâminas representando 261 espécies, 22 gêneros, incluindo 51 parátipos de 34 espécies. Mais de 90% dos espécimes foram coletados no Brasil dos quais metade são do Estado do Amazonas. As espécies representadas neste acervo são listadas indicando o número de espécimes para cada tipo de preparação e as localidades de coleta. O material tipo também é listado, incluindo os dados dos rótulos de identificação e de procedência, bem como outras informações pertinentes.The discovery of mosquito specimens that belonged to Nelson L. Cerqueira, which are being deposited in the Instituto Nacional de Pesquisas da Amazônia Invertebrate Collection, is reported. The collection contains 2,046 adult specimens and 387 slide preparations representing 261 species, 22 genera, including 51 paratypes of 34 species. More than 90% of the specimens were collected in Brazil of which half are from the State of Amazonas. A list of the species represented in this collection is provided indicating the number of specimens for each type of preparation and the collecting localities. The type specimens are also listed including their label data and other pertinent information.

  1. 75 FR 34720 - Notice of Intent To Prepare an Environmental Impact Statement and To Conduct Public Scoping...

    Science.gov (United States)

    2010-06-18

    ...-voltage direct current (HVDC) Voltage Source Converter (VSC) controllable transmission system from the... HVDC bipoles. A bipole consists of two connected submarine or underground cables, one of which is... project would originate at an HVDC converter station near Hydro-Qu[eacute]bec Trans[Eacute]nergie's 765...

  2. 77 FR 75623 - Notice of Intent To Prepare an Environmental Impact Statement for the Plains and Eastern Clean...

    Science.gov (United States)

    2012-12-21

    ... voltage direct current (HVDC) electric transmission system and associated facilities with the capacity to... project and supporting information. Clean Line's original proposal included two HVDC lines, each rated at..., Clean Line has modified its Section 1222 proposal to a single HVDC line with the capacity to deliver 3...

  3. 78 FR 50405 - Amended Application for Presidential Permit; Northern Pass Transmission LLC

    Science.gov (United States)

    2013-08-19

    ... Pass proposes to construct and operate a primarily overhead high-voltage direct current (HVDC) electric transmission line that would originate at an HVDC converter station to be constructed at the Des Cantons Substation in Qu[eacute]bec, Canada, then would be converted from HVDC to alternating current (AC) in...

  4. Senior Senator from Florida and Chairman, Senate Committee on Space, Aeronautics and Related Sciences W. Nelson, visiting the ATLAS cavern and LHC tunnel with ATLAS Collaboration Spokesperson P. Jenni and AMS Collaboration Spokesperson S.C.C.Ting, 16 March 2008.

    CERN Multimedia

    Maximilien Brice

    2008-01-01

    Senior Senator from Florida and Chairman, Senate Committee on Space, Aeronautics and Related Sciences W. Nelson, visiting the ATLAS cavern and LHC tunnel with ATLAS Collaboration Spokesperson P. Jenni and AMS Collaboration Spokesperson S.C.C.Ting, 16 March 2008.

  5. Tradição, tragicidade e crítica social em Dorotéia, a “farsa irresponsável” de Nelson Rodrigues

    Directory of Open Access Journals (Sweden)

    Sandra Amélia Luna Cirne de Azevêdo

    2014-07-01

    Full Text Available http://dx.doi.org/10.5007/2176-8552.2013n16p163 A verossimilhança sempre foi amplamente explorada pela imaginação artística. Poetas trágicos e cômicos tramaram situações as mais criativas, buscando mover o público ao riso ou às lágrimas. Tradicionalmente, entretanto, recaem limites sobre as representações dramáticas, a depender dos efeitos que os autores pretendem provocar. Assim, ainda que eventos impossíveis tenham participado da tragédia desde suas origens, e ainda que o humor tenha sido ocasionalmente acolhido nas tramas, o tratamento sério da ação sempre foi exigência da forma, de maneira a que o trágico não se fizesse cômico. Com o passar dos séculos, dramaturgos desafiariam as definições de tragédia e comédia, preparando as bases para o drama social. A dramatização de conflitos da vida burguesa rapidamente absorveria um amplo espectro de tons emocionais, abolindo convenções antigas em favor de um gênero que se quer lócus privilegiado de crítica social. O trágico poderia agora ser dramatizado sob perspectivas as mais diversas, inclusive farsescas. Este ensaio examina a tragicidade na peça Dorotéia, de Nelson Rodrigues, focalizando as relações da obra com a tradição e considerando, através do conceito de “dispositivo” formulado por Agamben, estratégias utilizadas pelo dramaturgo para produzir uma crítica sarcástica a valores e instituições sociais. Palavras-chave: Nelson Rodrigues; Dorotéia; Teoria do Drama; Tragédia Moderna; Teatro Brasileiro

  6. 77 FR 25472 - Amended Notice of Intent To Modify the Scope of the Environmental Impact Statement for the...

    Science.gov (United States)

    2012-04-30

    ... connect a 2,000-megawatt (MW) high-voltage direct current (HVDC) Voltage Source Converter (VSC... change in the project's design resulted in a proposed HVDC transmission line that would consist of a... alternative now consists of a single 1,000-MW HVDC bipole. The bipole is comprised of two connected submarine...

  7. Os cinco sentidos, tradução de Nelson Pimenta: reflexões sobre poesia surda no Youtube

    Directory of Open Access Journals (Sweden)

    Carla Cristina Gaia dos Santos

    2017-12-01

    Full Text Available As Comunidades Surdas encontram nas tecnologias comunicacionais atuais grandes aliados para divulgação e perpetuação de sua literatura, desconstruindo fronteiras geográficas e sociais que, muitas vezes, os isolavam uns dos outros. Se desde o advento da impressa a escrita tem assumido o papel central de transmissão e construção do conhecimento nas mais diversas áreas do saber, a época da comunicação virtual chega para nos lembrar de outras formas nem tão privilegiadas de significar e de comunicar. Através da internet os Surdos partilham suas histórias, poesias, piadas e muito mais. Baseando-nos em pesquisadores como Lévy (2015, Kress (2003 e Lemke (2010, o presente artigo objetiva refletir sobre a poesia Cinco Sentidos, tradução de Nelson Pimenta para a língua brasileira de sinais de Five Senses, do poeta briânico Paul Scott, disponível no ambiente virtual YouTube.

  8. The complete mitochondrial genome of the gall-forming fly, Fergusonina taylori Nelson and Yeates (Diptera: Fergusoninidae).

    Science.gov (United States)

    Nelson, Leigh A; Cameron, Stephen L; Yeates, David K

    2011-10-01

    The monogeneric family Fergusoninidae consists of gall-forming flies that, together with Fergusobia (Tylenchida: Neotylenchidae) nematodes, form the only known mutualistic association between insects and nematodes. In this study, the entire 16,000 bp mitochondrial genome of Fergusonina taylori Nelson and Yeates was sequenced. The circular genome contains one encoding region including 27 genes and one non-coding A+T-rich region. The arrangement of the protein-coding, ribosomal RNA (rRNA) and transfer RNA (tRNA) genes was the same as that found in the ancestral insect. Nucleotide composition is highly A+T biased. All of the protein initiation codons are ATN, except for nad1 which begins with TTT. All 22 tRNA anticodons of F. taylori match those observed in Drosophila yakuba, and all form the typical cloverleaf structure except for tRNA-Ser((AGN)) which lacks a dihydrouridine (DHU) arm. Secondary structural features of the rRNA genes of Fergusonina are similar to those proposed for other insects, with minor modifications. The mitochondrial genome of Fergusonina presented here may prove valuable for resolving the sister group to the Fergusoninidae, and expands the available mtDNA data sources for acalyptrates overall.

  9. Hybrid AC-High Voltage DC Grid Stability and Controls

    Science.gov (United States)

    Yu, Jicheng

    The growth of energy demands in recent years has been increasing faster than the expansion of transmission facility construction. This tendency cooperating with the continuous investing on the renewable energy resources drives the research, development, and construction of HVDC projects to create a more reliable, affordable, and environmentally friendly power grid. Constructing the hybrid AC-HVDC grid is a significant move in the development of the HVDC techniques; the form of dc system is evolving from the point-to-point stand-alone dc links to the embedded HVDC system and the multi-terminal HVDC (MTDC) system. The MTDC is a solution for the renewable energy interconnections, and the MTDC grids can improve the power system reliability, flexibility in economic dispatches, and converter/cable utilizing efficiencies. The dissertation reviews the HVDC technologies, discusses the stability issues regarding the ac and HVDC connections, proposes a novel power oscillation control strategy to improve system stability, and develops a nonlinear voltage droop control strategy for the MTDC grid. To verify the effectiveness the proposed power oscillation control strategy, a long distance paralleled AC-HVDC transmission test system is employed. Based on the PSCAD/EMTDC platform simulation results, the proposed power oscillation control strategy can improve the system dynamic performance and attenuate the power oscillations effectively. To validate the nonlinear voltage droop control strategy, three droop controls schemes are designed according to the proposed nonlinear voltage droop control design procedures. These control schemes are tested in a hybrid AC-MTDC system. The hybrid AC-MTDC system, which is first proposed in this dissertation, consists of two ac grids, two wind farms and a five-terminal HVDC grid connecting them. Simulation studies are performed in the PSCAD/EMTDC platform. According to the simulation results, all the three design schemes have their unique salient

  10. River water pollution condition in upper part of Brantas River and Bengawan Solo River

    Science.gov (United States)

    Roosmini, D.; Septiono, M. A.; Putri, N. E.; Shabrina, H. M.; Salami, I. R. S.; Ariesyady, H. D.

    2018-01-01

    Wastewater and solid waste from both domestic and industry have been known to give burden on river water quality. Most of river water quality problem in Indonesia has start in the upper part of river due to anthropogenic activities, due to inappropriate land use management including the poor wastewater infrastructure. Base on Upper Citarum River Water pollution problem, it is interesting to study the other main river in Java Island. Bengawan Solo River and Brantas River were chosen as the sample in this study. Parameters assessed in this study are as follows: TSS, TDS, pH, DO, and hexavalent chromium. The status of river water quality are assess using STORET method. Based on (five) parameters, STORET value showed that in Brantas River, Pagerluyung monitoring point had the worst quality relatively compared to other monitoring point in Brantas River with exceeding copper, lead and tin compared to the stream standard in East Java Provincial Regulation No. 2 in 2008. Brantas River was categorized as lightly polluted river based on monitoring period 2011-2015 in 5 monitoring points, namely Pendem, Sengguruh, Kademangan, Meritjan and Kertosono.

  11. Installation and operational effects of a HVDC submarine cable in a continental shelf setting: Bass Strait, Australia

    Directory of Open Access Journals (Sweden)

    John Sherwood

    2016-12-01

    Full Text Available Despite the many submarine telecommunications and power cables laid world-wide there are fewer than ten published studies of their environmental effects in the refereed literature. This paper describes an investigation into the effects of laying and operating the Basslink High Voltage Direct Current (HVDC cable and its associated metallic return cable across Bass Strait in South East Australia. Over more than 95% of its length the cable was directly laid into a wet jetted trench given the predominantly soft sediments encountered. Underwater remote video investigations found that within two years all visible evidence of the cable and trench was gone at over a third of the transects at six deep water sites (32–72m deep. At other deep water transects the residual trench trapped drift material providing habitat for the generally sparsely distributed benthic community. Diver surveys at both of the near shore sites (<15m deep on the northern side of the Strait also found the cable route was undetectable after a year. On the southern side, where the cable traversed hard basalt rock near shore, it was encased in a protective cast iron half shell. Ecological studies by divers over 3.5 years demonstrated the colonization of the hard shell by similar species occupying hard substrates elsewhere on the basalt reef. Magnetic field strengths associated with the operating cable were found to be within 0.8% of those predicted from theory with strength dropping rapidly with distance from the cable. Beyond 20m the field was indistinguishable from background.

  12. River-corridor habitat dynamics, Lower Missouri River

    Science.gov (United States)

    Jacobson, Robert B.

    2010-01-01

    Intensive management of the Missouri River for navigation, flood control, and power generation has resulted in substantial physical changes to the river corridor. Historically, the Missouri River was characterized by a shifting, multithread channel and abundant unvegetated sandbars. The shifting channel provided a wide variety of hydraulic environments and large areas of connected and unconnected off-channel water bodies.Beginning in the early 1800s and continuing to the present, the channel of the Lower Missouri River (downstream from Sioux City, Iowa) has been trained into a fast, deep, single-thread channel to stabilize banks and maintain commercial navigation. Wing dikes now concentrate the flow, and revetments and levees keep the channel in place and disconnect it from the flood plain. In addition, reservoir regulation of the Missouri River upstream of Yankton, South Dakota, has substantially changed the annual hydrograph, sediment loads, temperature regime, and nutrient budgets.While changes to the Missouri River have resulted in broad social and economic benefits, they have also been associated with loss of river-corridor habitats and diminished populations of native fish and wildlife species. Today, Missouri River stakeholders are seeking ways to restore some natural ecosystem benefits of the Lower Missouri River without compromising traditional economic uses of the river and flood plain.

  13. Power System Reliability Assessment by Analysing Voltage Dips on the Blue Horizon Bay 22KV Overhead Line in the Nelson Mandela Bay Municipality

    Science.gov (United States)

    Lamour, B. G.; Harris, R. T.; Roberts, A. G.

    2010-06-01

    Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.

  14. Gisela Cramer y Ursula Prutsch, editoras. ¡Américas unidas! Nelson A. Rockefeller’s Office of Inter-American Affairs (1940-46

    Directory of Open Access Journals (Sweden)

    David Andrew Corcoran

    2013-07-01

    Full Text Available Un tema muy poco conocido y con poca frecuencia estudiado es la constitución de la Oficina de Asuntos Interamericanos (OIAA, en inglés, que orquesto una reestructuración de las relaciones entre Estados Unidos y América Latina durante de la Segunda Guerra Mundial. Abandonando de esta manera los limites de la diplomacia tradicional (gobierno a gobierno, los programas OIAA pusieron al gobierno de EE.UU. y a sus ciudadanos por primera vez en contacto directo con sectores amplios del pueblo latinoamericano. Bajo la dirección del joven Nelson Rockefeller y con la clara intención de frenar la influencia del poder nazi y del eje en la región, la OIAA dio sustento a la política del buen vecino.

  15. InfiniBand-based real-time simulation of HVDC, STATCOM and SVC devices with commercial-off-the-shelf PCs and FPGAs

    Energy Technology Data Exchange (ETDEWEB)

    Dufour, C.; Abourida, S.; Belanger, J.; Lapointe, V. [OPAL-RT Technologies Inc., Montreal, PQ (Canada)

    2006-07-01

    Details of a real-time simulator for large power networks using commercial-off-the-shelf products and an RT-LAB platform were presented. The simulator was designed to realistically simulate bipolar high voltage DC (HVDC) networks transmission systems and to meet large grid simulation challenges. The system was also designed to cope with complex power grid design and validation tests as well as to interface with modern power electronic controllers and protection systems. The platform used Pentium, Xeon or Opteron based PCs and InfiniBand communication fabric for fast inter-PC communications. The real-time PC ran under well-known operating systems while the main control interface used Simulink software. Grid circuits were designed using an SPS interface using an ARTEMIS plug-in. Various model performances were reported. The results of several simulations suggested that InfiniBand communication was slower than shared-memory communication, while STATCOM timing was difficult to compare with the Opteron benchmarks. Results also suggested that XEON CPUs were slower than Opteron counterparts. Hardware-in-the-loop (HIL) testing was also performed with a prototype controller and with a real production controller. It was concluded that a communication time of 5 microseconds was obtained across the 2 PCs. The paper also discussed recent advances in HIL simulation and programming devices. 10 refs., 15 figs.

  16. Off-shore wind power plant modelling precision and efficiency in electromagnetic transient simulation programs

    Energy Technology Data Exchange (ETDEWEB)

    Karaagac, U.; Saad, H.; Mahseredjian, J. [Ecole Polytechnique de Montreal, Montreal, QC (Canada); Jensen, S.; Cai, L. [REpower Systems AG, Hamburg (Germany)

    2012-07-01

    The large number of switching elements in the modular multilevel converter (MMC) is a challenging problem for modeling the MMC-HVDC systems in electromagnetic transient type (EMT-type) programs. The modeling complexity increases even further when MMC-HVDC systems are used to integrate offshore wind farms (OWFs) with power electronics based wind energy converters, such as doubly-fed induction generators (DFIGs). This paper compares the computational performances of various combinations of MMC-HVDC and OWF models. Practical onshore ac fault scenarios are simulated for an OWF composed of DFIG type wind turbines and connected to a practical ac grid through a point-to-point MMC-HVDC system. (orig.)

  17. Peripartum hysterectomy: two years experience at Nelson Mandela Academic hospital, Mthatha, Eastern Cape South Africa.

    Science.gov (United States)

    Wandabwa, J N; Businge, C; Longo-Mbenza, B; Mdaka, M L; Kiondo, P

    2013-06-01

    Obstetric haemorrhage is the leading direct cause of maternal mortality in South Africa. To determine the incidence, indications, associations and maternal outcomes of emergency peripartum hysterectomies. A descriptive and retrospective analysis of patients who had peripartum hysterectomy between 1(st) February 2007 and 31(st) January 2009 in Nelson Mandela Academic Hospital at Mthatha city. The incidence of 0.95% of peripartum hysterectomies (n=63 or 9.5/1000 births) increased with the increasing maternal age from 0.121% at age of less than 20 years to 0.5% at age more or equal to 30 years. Similarly the incidence increased with parity from 0.332% for Primiparity to 0.468% at parity of four or more. The indications for the operation were uterine atony 19/63 (30.2%), secondary haemorrhage/puerperal sepsis 17/63 (27%) and ruptured uterus 16/63 (23.4%). The main intra operative complication was haemorrhage 13/63 (20.6%). Repeat laparotomy was done in 10/63 (15%) of patients due to haemorrhage. Admission to intensive care unit was 25/63 (39.7%). The case specific mortality rate was of 19 % (n=12). The main causes of death were hypovolaemic shock and septicemia. The incidence of peripartum hysterectomies was high and was associated with ruptured uterus and puerperal sepsis which are preventable.

  18. A cinema of presence and proximity: Gunvor Nelson's collage films and the aesthetics of the signaletic material before the electronic signal

    Directory of Open Access Journals (Sweden)

    John Sundholm

    2012-06-01

    Full Text Available This essay argues for the importance of an intersubjective and impure film theory in which the signal and the signaletic is considered as figures for approaching film. This in order to make the argument that the signaletic mode indeed enables a novel perspective on moving image history. The aesthetics of the signaletic has thus a history preceding that of electronic media, in particular when it comes to animation and experimental film. When constructing such an archaeology, however, dichotomies into sign and signal should be avoided; otherwise, the complexity of many of the films is reduced. In order to illuminate the latter point, four films by Gunvor Nelson is analyzed (both analog and digital, showing not only how both sign and signal interact but also how the aesthetics of the signal and the signaletic material is not dependant on the electronic as such.

  19. Hacer globalización desde Ecuador. El tercer espacio como utopía para el ecuatoriano en Timarán y Cuabú de Nelson Estupiñán Bass

    Directory of Open Access Journals (Sweden)

    Wilfried Mvondo

    2016-07-01

    Full Text Available Este ensayo estudia cómo Nelson Estupiñán Bass da cuenta de la dinámica de la creación del tercer espacio en Ecuador con relación a la utopía de progreso socioeconómico que esta arrastra. Contempla la articulación entre “tercer espacio” y “utopía”. Este trabajo, que se apoya en el enfoque sociocrítico, analiza el espacio en Timarán y Cuabú y las inscripciones ideológicas que en ello afloran. Culmina en los siguientes resultados: 1 el tercer espacio es un lugar de intereses y resistencia para el ecuatoriano;y 2 este espacio suscita cierta utopía de desarrollo en el ecuatoriano. This paper studies how Nelson Estupiñán Bass realizes the dynamics in the creation of the third space in Ecuador relative to the utopia of socio-economic progress dragged by the latter. The study focuses on the articulation of the “third space” and the “utopia”. As this work is based on the sociocritical approach, it analyses the space from Timarán y Cuabú and the ideologies that it outcrops. The study deals with the following findings: 1 the third space is a space of interests and resistance for the Ecuadorian and 2 that space create a utopia of development in the Ecuadorian.

  20. High voltage direct current transmission converters, systems and DC grids

    CERN Document Server

    Jovcic, Dragan

    2015-01-01

    This comprehensive reference guides the reader through all HVDC technologies, including LCC (Line Commutated Converter), 2-level VSC and VSC HVDC based on modular multilevel converters (MMC) for an in-depth understanding of converters, system level design, operating principles and modeling. Written in a tutorial style, the book also describes the key principles of design, control, protection and operation of DC transmission grids, which will be substantially different from the practice with AC transmission grids. The first dedicated reference to the latest HVDC technologies and DC grid developments; this is an essential resource for graduate students and researchers as well as engineers and professionals working on the design, modeling and operation of DC grids and HVDC.

  1. Provision of antiretroviral therapy for children in Nelson Mandela Bay: Health care professionals’ challenges

    Science.gov (United States)

    2018-01-01

    Background The human immunodeficiency virus and/or acquired immune deficiency syndrome (HIV/AIDS) pandemic continues to increase in prevalence worldwide, particularly in South Africa, and includes the often overlooked paediatric population. The provision of paediatric antiretroviral treatment (ART) is as essential for children as for adults, and has numerous obstacles, not least of which is lack of decentralisation of facilities to provide essential treatment. Optimising ART, care and support for HIV-positive children, and their caregivers, at public sector primary health care (PHC) clinics is crucial to improve morbidity and mortality rates in children. Aim To explore the experiences of health care professionals regarding the provision of ART for children at PHC clinics. Setting The study was conducted in six PHC clinics in Nelson Mandela Bay Health District, Eastern Cape, South Africa. Methodology The researchers used a qualitative, explorative, descriptive and contextual research design with in-depth interviews. We used non-probability purposive sampling. Data collected were thematically analysed using Creswell’s data analysis spiral. We used Lincoln and Guba’s model to ensure trustworthiness. Ethical standards were applied. Results Health care professionals experienced numerous challenges, such as lack of resources, need for training, mentoring and debriefing, all related to providing decentralised ART for HIV-positive children at the PHC level. Conclusion Capacitation of the health care system, integration of services, competent management and visionary leadership to invoke a collaborative interdisciplinary team approach is required to ensure that HIV is treated as a chronic disease at the PHC clinic level. PMID:29781680

  2. Provision of antiretroviral therapy for children in Nelson Mandela Bay: Health care professionals' challenges.

    Science.gov (United States)

    Williams, Margaret; Van Rooyen, Dalena R M; Ricks, Esmeralda J

    2018-03-12

     The human immunodeficiency virus and/or acquired immune deficiency syndrome (HIV/AIDS) pandemic continues to increase in prevalence worldwide, particularly in South Africa, and includes the often overlooked paediatric population. The provision of paediatric antiretroviral treatment (ART) is as essential for children as for adults, and has numerous obstacles, not least of which is lack of decentralisation of facilities to provide essential treatment. Optimising ART, care and support for HIV-positive children, and their caregivers, at public sector primary health care (PHC) clinics is crucial to improve morbidity and mortality rates in children.  To explore the experiences of health care professionals regarding the provision of ART for children at PHC clinics.  The study was conducted in six PHC clinics in Nelson Mandela Bay Health District, Eastern Cape, South Africa.  The researchers used a qualitative, explorative, descriptive and contextual research design with in-depth interviews. We used non-probability purposive sampling. Data collected were thematically analysed using Creswell's data analysis spiral. We used Lincoln and Guba's model to ensure trustworthiness. Ethical standards were applied.  Health care professionals experienced numerous challenges, such as lack of resources, need for training, mentoring and debriefing, all related to providing decentralised ART for HIV-positive children at the PHC level.  Capacitation of the health care system, integration of services, competent management and visionary leadership to invoke a collaborative interdisciplinary team approach is required to ensure that HIV is treated as a chronic disease at the PHC clinic level.

  3. A reassessment of North American river basin water balances in light of new estimates of mountain snow accumulation

    Science.gov (United States)

    Wrzesien, M.; Durand, M. T.; Pavelsky, T.

    2017-12-01

    The hydrologic cycle is a key component of many aspects of daily life, yet not all water cycle processes are fully understood. In particular, water storage in mountain snowpacks remains largely unknown. Previous work with a high resolution regional climate model suggests that global and continental models underestimate mountain snow accumulation, perhaps by as much as 50%. Therefore, we hypothesize that since snow water equivalent (one aspect of the water balance) is underestimated, accepted water balances for major river basins are likely wrong, particularly for mountainous river basins. Here we examine water balances for four major high latitude North American watersheds - the Columbia, Mackenzie, Nelson, and Yukon. The mountainous percentage of each basin ranges, which allows us to consider whether a bias in the water balance is affected by mountain area percentage within the watershed. For our water balance evaluation, we especially consider precipitation estimates from a variety of datasets, including models, such as WRF and MERRA, and observation-based, such as CRU and GPCP. We ask whether the precipitation datasets provide enough moisture for seasonal snow to accumulate within the basin and whether we see differences in the variability of annual and seasonal precipitation from each dataset. From our reassessment of high-latitude water balances, we aim to determine whether the current understanding is sufficient to describe all processes within the hydrologic cycle or whether datasets appear to be biased, particularly in high-elevation precipitation. Should currently-available datasets appear to be similarly biased in precipitation, as we have seen in mountain snow accumulation, we discuss the implications for the continental water budget.

  4. [Health assessment of river ecosystem in Haihe River Basin, China].

    Science.gov (United States)

    Hao, Li-Xia; Sun, Ran-Hao; Chen, Li-Ding

    2014-10-01

    With the development of economy, the health of river ecosystem is severely threatened because of the increasing effects of human activities on river ecosystem. In this paper, the authors assessed the river ecosystem health in aspects of chemical integrity and biological integrity, using the criterion in water quality, nutrient, and benthic macroinvertebrates of 73 samples in Haihe River Basin. The research showed that the health condition of river ecosystem in Haihe River Basin was bad overall since the health situation of 72. 6% of the samples was "extremely bad". At the same time, the health situation in Haihe River Basin exhibited obvious regional gathering effect. We also found that the river water quality was closely related to human activities, and the eutrophication trend of water body was evident in Haihe River Basin. The biodiversity of the benthic animal was low and lack of clean species in the basin. The indicators such as ammonia nitrogen, total nitrogen and total phosphorus were the key factors that affected the river ecosystem health in Haihe River Basin, so the government should start to curb the deterioration of river ecosystem health by controlling these nutrients indicators. For river ecosystem health assessment, the multi-factors comprehensive evaluation method was superior to single-factor method.

  5. River habitat assessment for ecological restoration of Wei River Basin, China.

    Science.gov (United States)

    Yang, Tao; Wang, Shuo; Li, Xiaoping; Wu, Ting; Li, Li; Chen, Jia

    2018-04-11

    As an important composition component of river ecosystems, river habitats must undergo quality assessment to potentially provide scientific basis for river ecological restoration. Substrate composition, habitat complexity, bank erosion degree, river meandering degree, human activity intensity, vegetation buffer width, water quality, and water condition were determined as indicators for river habitat assessment. The comprehensive habitat quality index (CHQI) was established for the Wei River Basin. In addition, the indicator values were determined on the basis of a field investigation at 12 national hydrological stations distributed across the Wei, Jing, and Beiluo Rivers. The analytic hierarchy process was used to determine the indicator weights and thus distinguish the relative importance of the assessment indicator system. Results indicated that the average CHQIs for the Wei, Jing, and Beiluo Rivers were 0.417, 0.508, and 0.304, respectively. The river habitat quality for the three rivers was well. As for the whole river basin, the river habitat quality for 25% of the cross section was very well, the other 25% was well, and the 50% remaining was in critical state. The river habitat quality of the Jing River was better than that of the Wei and Beiluo Rivers.

  6. Report of Freshwater Mollusks Workshop 19-20 May 1981.

    Science.gov (United States)

    1982-05-01

    RELOCATION OF LAMPSILIS HIGGINSI IN THE UPPER MISSISSIPPI RIVER ....... ....................... 104 David Nelson HIGGINS ’ EYE MUSSEL RECOVERY PLAN...0830 The Higgins ’ Eye Mussel Recovery Team - Dr. Edward Stern, University of Wisconsin Dealing with Endangered Mollusks at Corps of Engineers District...typically dark yellowish-brown to brown in color. Quadrula stapes appears to be most closely related to Q. intermedia which is endemic to the Tennessee

  7. A RETROSPECTIVE ANALYSIS OF ACUTE APPENDICITIS, RUPTURED APPENDICITIS AND THE LEVEL OF LEUKOCYTOSIS IN PAEDIATRIC SURGICAL PATIENTS OF NELSON MANDELA CENTRAL HOSPITAL.

    Science.gov (United States)

    Mtimba, L; Dhaffala, A; Molaoa, S Z

    2017-06-01

    Appendicectomy is the most commonly performed operation worldwide. The diagnosis is predominantly based on clinical findings. Some patients will clinically be unclear if ruptured or acute inflamed appendicitis; the level of white cell count has been used as the predictor for ruptured appendicitis. This was a retrospective chart review of paediatric surgical patients admitted at Nelson Mandela Central Hospital, Mthatha South Africa. A total of 214 patients with a diagnosis of acute appendicitis. Overall, the ruptured appendicitis was 62% and 38% were inflamed appendicitis. Nature of the acute appendicitis: White cell count, Inflamed, Ruptured, Total p-value 30 0 4 4. This study has demonstrated that in patients who are diagnosed with acute appendicitis clinically, the normal white cell count does not necessarily rule out ruptured acute appendicitis. But the risks of ruptured acute appendicitis increase with the increase level of white cell count.

  8. 76 FR 51887 - Safety Zone; Patuxent River, Patuxent River, MD

    Science.gov (United States)

    2011-08-19

    ...-AA00 Safety Zone; Patuxent River, Patuxent River, MD AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a temporary safety zone during the ``NAS Patuxent River... held over certain waters of the Patuxent River adjacent to Patuxent River, Maryland from September 1...

  9. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  10. 50 CFR 226.205 - Critical habitat for Snake River sockeye salmon, Snake River fall chinook salmon, and Snake River...

    Science.gov (United States)

    2010-10-01

    ... salmon, Snake River fall chinook salmon, and Snake River spring/summer chinook salmon. 226.205 Section... Snake River sockeye salmon, Snake River fall chinook salmon, and Snake River spring/summer chinook salmon. The following areas consisting of the water, waterway bottom, and adjacent riparian zone of...

  11. Numerical modelling of river processes: flow and river bed deformation

    NARCIS (Netherlands)

    Tassi, P.A.

    2007-01-01

    The morphology of alluvial river channels is a consequence of complex interaction among a number of constituent physical processes, such as flow, sediment transport and river bed deformation. This is, an alluvial river channel is formed from its own sediment. From time to time, alluvial river

  12. 33 CFR 117.734 - Navesink River (Swimming River).

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Navesink River (Swimming River). 117.734 Section 117.734 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... (Swimming River). The Oceanic Bridge, mile 4.5, shall open on signal; except that, from December 1 through...

  13. Operation of river systems. The Otra river

    International Nuclear Information System (INIS)

    Harby, A.; Vaskinn, K.A.; Wathne, M.; Heggenes, J.; Saltveit, S.J.

    1993-12-01

    The purpose of the project described in this report was to prepare an operative tool for making decisions about the operation of the power system on the river Otra (Norway) with regard to how this operation might affect the various users of the river system. Above all this affects fish, outdoor life and esthetic values. The connection between water quality and volume of discharge has been examined in a sub project. How suitable parts of the river are as habitats for trout has been simulated on a computer. From field investigation it is concluded that near the Steinfoss power station the physical conditions for trout depend on the operation of the river system. Outdoor life is not much affected downstream Vikeland. 11 refs., 22 figs., 2 tabs

  14. 33 CFR 165.150 - New Haven Harbor, Quinnipiac River, Mill River.

    Science.gov (United States)

    2010-07-01

    ... River, Mill River. 165.150 Section 165.150 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... New Haven Harbor, Quinnipiac River, Mill River. (a) The following is a regulated navigation area: The... 303°T to point D at the west bank of the mouth of the Mill River 41°18′05″ N, 72°54′23″ W thence south...

  15. Environmental impact management during construction of the limestone project

    International Nuclear Information System (INIS)

    Windsor, D.C.

    1988-01-01

    The Limestone Generating Station is being constructed on the Nelson River in Northern Manitoba, and will consist of a 10 unit powerhouse, 5 gate concrete spillway and earthfill dam spanning the 1.5 km width of the Nelson River. Environmental concerns associated with the project included insufficient pre- and post-construction monitoring documenting resources present or magnitude of impacts, impacts on brook trout and lake sturgeon resources, wildlife habitat loss due to construction activities, destruction or disturbance of historic or archaeological sites, degradation of nearby water courses and fish habitat by aggregate removal, in-migration of construction personnel, and various other socio-economic impacts. An overview is provided of monitoring activities and results in the above areas, which involved numerous consultants and government agencies. The project administration and workers did not find the environmental programs, including inspection and enforcement activities, to be onerous or an impediment to the project. On the contrary, the environmental requirements assisted in the general planning for certain activities, and in the general criteria for the conduct of the activities. The work permit process was particularly useful as it defined the requirements of both parties and provided the specific standards necessary determining the acceptability of the activities. 14 refs., 1 fig

  16. Many rivers to cross. Cross border co-operation in river management

    NARCIS (Netherlands)

    Verwijmeren, J.A.; Wiering, M.A.

    2007-01-01

    River basin management is a key concept in contemporary water policy. Since the management of rivers is best designed and implemented at the scale of the river basin, it seems obvious that we should not confine ourselves to administrative or geographical borders. In other words, river basin

  17. Dive Angle Sensitivity Analysis for Flight Test Safety and Efficiency

    Science.gov (United States)

    2010-03-01

    22]. Raymer points out that most flutter modes are driven by improper balancing of control surfaces, but these flutter modes can be excited...description1.html [cited 2 Feb. 2010] [10] Nelson, Robert C., Flight Stability and Automatic Control, 2nd ed., McGraw-Hill Higher Education, Boston...Patuxent River Naval Air Station MD, May 1992, Chap. 10 [15] Raymer , Daniel, P., Aircraft Design: A Conceptual Approach, 4th ed., AIAA Education

  18. Global Climate Model Simulated Hydrologic Droughts and Floods in the Nelson-Churchill Watershed

    Science.gov (United States)

    Vieira, M. J. F.; Stadnyk, T. A.; Koenig, K. A.

    2014-12-01

    There is uncertainty surrounding the duration, magnitude and frequency of historical hydroclimatic extremes such as hydrologic droughts and floods prior to the observed record. In regions where paleoclimatic studies are less reliable, Global Climate Models (GCMs) can provide useful information about past hydroclimatic conditions. This study evaluates the use of Coupled Model Intercomparison Project 5 (CMIP5) GCMs to enhance the understanding of historical droughts and floods across the Canadian Prairie region in the Nelson-Churchill Watershed (NCW). The NCW is approximately 1.4 million km2 in size and drains into Hudson Bay in Northern Manitoba, Canada. One hundred years of observed hydrologic records show extended dry and wet periods in this region; however paleoclimatic studies suggest that longer, more severe droughts have occurred in the past. In Manitoba, where hydropower is the primary source of electricity, droughts are of particular interest as they are important for future resource planning. Twenty-three GCMs with daily runoff are evaluated using 16 metrics for skill in reproducing historic annual runoff patterns. A common 56-year historic period of 1950-2005 is used for this evaluation to capture wet and dry periods. GCM runoff is then routed at a grid resolution of 0.25° using the WATFLOOD hydrological model storage-routing algorithm to develop streamflow scenarios. Reservoir operation is naturalized and a consistent temperature scenario is used to determine ice-on and ice-off conditions. These streamflow simulations are compared with the historic record to remove bias using quantile mapping of empirical distribution functions. GCM runoff data from pre-industrial and future projection experiments are also bias corrected to obtain extended streamflow simulations. GCM streamflow simulations of more than 650 years include a stationary (pre-industrial) period and future periods forced by radiative forcing scenarios. Quantile mapping adjusts for magnitude

  19. High-voltage direct-current circuit breakers

    International Nuclear Information System (INIS)

    Yoshioka, Y.; Hirasawa, K.

    1991-01-01

    This paper reports that in 1954 the first high-voltage direct-current (HVDC) transmission system was put into operation between Gotland and the mainland of Sweden. Its system voltage and capacity were 100 kV and 20 MW, respectively. Since then many HVDC transmission systems have been planned, constructed, or commissioned in more than 30 places worldwide, and their total capacity is close to 40 GW. Most systems commissioned to date are two-terminal schemes, and HVDC breakers are not yet used in the high-potential main circuit of those systems, because the system is expected to perform well using only converter/inverter control even at a fault stage of the transmission line. However, even in a two-terminal scheme there are not a few merits in using an HVDC breaker when the system has two parallel transmission lines, that is, when it is a double-circuit system

  20. [Nutrients Input Characteristics of the Yangtze River and Wangyu River During the "Water Transfers on Lake Taihu from the Yangtze River"].

    Science.gov (United States)

    Pan, Xiao-xue; Ma, Ying-qun; Qin, Yan-wen; Zou, Hua

    2015-08-01

    Overall 20 surface water samples were collected from the Yangtze River, the Wangyu River and the Gonghu Bay (Lake Taihu) to clarify the pollution characteristics of nitrogen and phosphorus during 2 sample stages of "Water Transfers on Lake Taihu from the Yangtze River" in August and December of 2013 respectively. The results showed that the mass concentrations of NO2- -N, NO3- -N, NH4+ -N and TN in the Gonghu Bay were lower than those of the Yangtze River and Wangyu River during the 2 water transfer processes. However, there was higher level of DON content in the Gonghu Bay than that of the Yangtze River and Wangyu River. The percentages of various N species showed that NO3- -N was the major N species in the Yangtze River and Wangyu River during the 2 water transfer processes. TP contents in samples collected from the Yangtze River displayed a constant trend compared with the Wangyu River. However, the percentages of various P species were different with each other during the 2 water transfer processes. Mass concentrations of DON and TP in surface water in August were higher than those in December and the contents of NO3- -N and TDP were lower in August than those in December. In general, NO3- -N and TPP were the main N and P species in Wangyu River from the Yangtze River. NO3- -N, PO4(3-) -P and TPP were the main N and P species in Gonghu Bay from Wangyu River during the 2 water transfer processes.