  1. Spread of fluid: Role of tip configurations in needles

    DEFF Research Database (Denmark)

    Gomes, Silvana; Drakidis, Alexandros Dimitrios; Silva, Patricia

    2017-01-01

    data were obtained after injecting 0.3 mL of fluid into a foamed polymer model with a velocity of 2 mm/s. The spread area and the depth were determined for 3 different types of hypodermic needles: Single channel needles with bevel tip and blunt tip and a needle with conical tip and 3 internal channels......During the injection of a fluid in a tissue model, the fluid might be affected by the needle tip configuration and the number of channels. Thus, the objective of the present work is to observe the influence of different needle tips and number of channels on the spread of a fluid. Fluid distribution...

  2. [Improvement of sonographic visualization of cannula needle tips by alignment of the needle lumen : In vitro investigation of established needle tip forms].

    Science.gov (United States)

    Schwemmer, U; Geppert, T; Steinfeldt, T; Wunder, C

    2015-10-13

    In the context of ultrasound-guided peripheral nerve blocks (regional anesthesia), clear visualization of the needle tip and the target structure are mandatory for the performance of a safe puncture and injection. The purpose of this in vitro study was to analyze the visualization of different forms of needle tips and calibers of cannulas in a phantom simulating human tissue, with the help of a standardized image analysis system. Different depths and angles of the puncture needle in relation to the ultrasound probe were tested. Cannula needles established for use in regional anesthesia with different surfaces, diameters and needle tip form in 23 different combinations were analyzed. A gelatine-based phantom was used to simulate human tissue. The standardized visualization of the needle tip with the ultrasound probe was performed in plane at different angles (30°, 45° and 60°), depths of penetration (1 cm, 2 cm and 3 cm) and two different alignments of the cannula needle lumen to the ultrasound probe (0° and 180°). The screenshots of the ultrasound pictures were analyzed by quantifying the pixel brightness around the needle tip (region of interest) with a standardized software (score 0-255). In this study 1104 ultrasound images of cannula needles were analyzed. Diminished scores (reduced pixel brightness) of the needle tips were documented with increasing distance from the ultrasound probe. Comparison of punctures at angles of 30° and 45° showed no differences in needle tip visibility (same scores) but punctures at an angle of 60° were poorly visualized compared with 30° and 45° (mean scores 87.90 ± 11.60 vs. 78.40 ± 12.07, p cannula lumen towards the ultrasound probe (0°) was significantly more easily visualized when compared with the reverse alignment of 180° (mean scores 86.90 ± 12.74 vs. 84.80 ± 11.66, p = 0.003, respectively). No differences in visibility were detected between the different cannula needle diameters

  3. TIPS Placement in Swine, Guided by Electromagnetic Real-Time Needle Tip Localization Displayed on Previously Acquired 3-D CT

    International Nuclear Information System (INIS)

    Solomon, Stephen B.; Magee, Carolyn; Acker, David E.; Venbrux, Anthony C.

    1999-01-01

    Purpose: To determine the feasibility of guiding a transjugular intrahepatic portosystemic shunt (TIPS) procedure with an electromagnetic real-time needle tip position sensor coupled to previously acquired 3-dimensional (3-D) computed tomography (CT) images. Methods: An electromagnetic position sensor was placed at the tip of a Colapinto needle. The real-time position and orientation of the needle tip was then displayed on previously acquired 3-D CT images which were registered with the five swine. Portal vein puncture was then attempted in all animals. Results: The computer calculated accuracy of the position sensor was on average 3 mm. Four of five portal vein punctures were successful. In the successes, only one or two attempts were necessary and success was achieved in minutes. Conclusion: A real-time position sensor attached to the tip of a Colapinto needle and coupled to previously acquired 3-D CT images may potentially aid in entering the portal vein during the TIPS procedure

  4. Characterizing tissue stiffness at the tip of a rigid needle using an opto-mechanical force sensor (Conference Presentation)

    Science.gov (United States)

    Beekmans, Steven V.; Iannuzzi, Davide; van den Dobbelsteen, John J.

    2016-03-01

    Each year, in the Netherlands alone, more than 50.000 percutaneous procedures are performed for treatment or for removal of tissue from possibly diseased organs, of which 30% return non-diagnostic due to erroneous needle targeting, often as a result of non-homogeneity of the penetrated tissue. In this study, we aim to facilitate needle targeting by assessing the tissue in front of the needle based on its mechanical properties. A probe that can identify tissues via real-time measurements of their mechanical properties is placed at the tip of the needle. The probe, actuated by a remote system at the distal part of the needle, employs the bending of a micro-machined cantilever fabricated on top of an optical fiber. The displacement of the cantilever, imposed by pressing a micro-bead (r = 75 µm) glued at the tip of the cantilever against the tissue, is interrogated by Fabry-Pérot interferometry and converted to force acted on the tissue in real-time. The force transducer is able to perform in harsh environments due to its monolithic design and all-optical working principle. Using our setup, load-indentation curves were obtained during needle insertion in several gelatin-based specimens. We demonstrate the ability of our device to detect and quantify layers of varying stiffness and to successfully locate tissue boundaries in animal tissue embedded in gelatin. Furthermore, a diagnostic measurement can be made by quantifying intra-organ tissue stiffness at the needle target location.

  5. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types.

    Directory of Open Access Journals (Sweden)

    Lyubomyr Lytvynchuk

    Full Text Available A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements.

  6. Needle Tip Visibility in 3D Ultrasound Images

    NARCIS (Netherlands)

    M. Arif (Muhammad); A. Moelker (Adriaan); T.W. van Walsum (Theo)

    2017-01-01

    textabstractAim: Needle visibility is crucial for effective and safe ultrasound-guided interventional procedures. Several studies have investigated needle visibility in 2D ultrasound imaging, but less information is available for 3D ultrasound imaging, a modality that has great potential for image

  7. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety.

    Science.gov (United States)

    Fujii, Chieko

    2013-01-01

    Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures. Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined. Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed. This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.

  8. Totally implantable port management: impact of positive pressure during needle withdrawal on catheter tip occlusion (an experimental study).

    Science.gov (United States)

    Lapalu, Jordane; Losser, Marie-Reine; Albert, Odile; Levert, Albert; Villiers, Stéphane; Faure, Pierre; Douard, Marie-Cécile

    2010-01-01

    Totally implanted ports (TIP) have become a standard part of patient care, providing long-term central venous access for treatment administration and other procedures. Despite overall the safety and effectiveness of TIP, complications still occur. Negative pressure created during needle withdrawal induces blood reflux and subsequent catheter occlusion. Application of positive pressure during needle withdrawal is thought to largely prevent such reflux, but supporting data are limited. To quantify the role of positive pressure, using a test model designed to simulate physiological conditions. Reflux associated with needle withdrawal with and without applied positive pressure was tested using various TIP models from different manufacturers mounted on a specially designed test bench. In addition to the presence or absence of positive pressure during needle withdrawal, study variables comprised of needle type (safety and standard), needle gauge and port septum diameter. Application of positive pressure during needle withdrawal reduced the incidence of reflux during needle withdrawal by nearly 80% (22% vs. 99%, ppressure. In the absence of positive pressure, mean reflux increased with septum diameter and needle gauge to a statistically significant extent. None of these variables significantly affected reflux in the context of needle withdrawal under positive pressure. The results of this study support the use of positive pressure during needle withdrawal to prevent blood reflux potentially leading to catheter tip occlusion.

  9. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety

    Directory of Open Access Journals (Sweden)

    Fujii C

    2013-07-01

    Full Text Available Chieko FujiiFaculty of Nursing and Medical Care, Keio University, Kanagawa, JapanBackground: Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures.Methods: Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined.Results: Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed.Conclusion: This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.Keywords: blood collection, nerve damage, motion analysis, patient safety, puncture angle, clinical education

  10. [Acupuncture therapy for regaining consciousness in terms of acupoint location, needle insertion and needle manipulation].

    Science.gov (United States)

    Meng, Xianggang; Gu, Wenlong; Ma, Fen; Du, Yuzheng; Zhao, Qi

    2015-03-01

    Acupuncture therapy for regaining consciousness activates soreness, numbness, distention, heaviness, radiating and moving, electric shock and ant climbing sensations at the specific acupoints in the stroke patients. Radiating and moving sensations are the summary of needling sensations such as soreness, numbness and twitching presenting during lifting and thrusting manipulation. These sensations are the essential factors of the therapeutic effect of regaining consciousness. Radiating sensation refers to the conduction along meridians and radiation of soreness and numbness. Moving sensation refers to the local muscular twitching at acupoints and the involuntary movement of limbs, joints and the distal. Acupuncture at the specific acupoints achieves radiating and moving sensations for promoting the circulation in meridians, regulating qi and mind and balancing yin and yang in stroke patients. This therapy was introduced in the paper in view of acupoint location, needle insertion and manipulation.

  11. Precision of Needle Tip Localization Using a Receiver in the Needle

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav Ivanov; Jensen, Jørgen Arendt

    2008-01-01

    ) scanning. The position of the tip is found via triangulation which involves solving a system of linear equations. The robustness to noise is ensured through averaging a number of estimates. The sensor is a ring of piezo-electric film making it possible to receive waves from any direction. The results were...... obtained using simulations in Field II. The center frequency is 7 MHz. The transducer array is mechanically focused in elevation plane at 25 mm while the height of the elements is 4.5 mm. The transducer pitch is 202 microns. The sensor is a ring with height of 1 mm and 2 mm diameter. Positions were varied...

  12. Needle gauge and tip designs for preventing post-dural puncture headache (PDPH).

    Science.gov (United States)

    Arevalo-Rodriguez, Ingrid; Muñoz, Luis; Godoy-Casasbuenas, Natalia; Ciapponi, Agustín; Arevalo, Jimmy J; Boogaard, Sabine; Roqué I Figuls, Marta

    2017-04-07

    Post-dural puncture headache (PDPH) is one of the most common complications of diagnostic and therapeutic lumbar punctures. PDPH is defined as any headache occurring after a lumbar puncture that worsens within 15 minutes of sitting or standing and is relieved within 15 minutes of the patient lying down. Researchers have suggested many types of interventions to help prevent PDPH. It has been suggested that aspects such as needle tip and gauge can be modified to decrease the incidence of PDPH. To assess the effects of needle tip design (traumatic versus atraumatic) and diameter (gauge) on the prevention of PDPH in participants who have undergone dural puncture for diagnostic or therapeutic causes. We searched CENTRAL, MEDLINE, Embase, CINAHL and LILACS, as well as trial registries via the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) search portal in September 2016. We adopted the MEDLINE strategy for searching the other databases. The search terms we used were a combination of thesaurus-based and free-text terms for both interventions (lumbar puncture in neurological, anaesthesia or myelography settings) and headache. We included randomized controlled trials (RCTs) conducted in any clinical/research setting where dural puncture had been used in participants of all ages and both genders, which compared different tip designs or diameters for prevention of PDPH DATA COLLECTION AND ANALYSIS: We used the standard methodological procedures expected by Cochrane. We included 70 studies in the review; 66 studies with 17,067 participants were included in the quantitative analysis. An additional 18 studies are awaiting classification and 12 are ongoing. Fifteen of the 18 studies awaiting classification mainly correspond to congress summaries published before 2010, in which the available information does not allow the complete evaluation of all their risks of bias and characteristics. Our main outcome was prevention of PDPH, but we also

  13. Human-robot collaborated path planning for bevel-tip needle steering in simulated human environment.

    Science.gov (United States)

    Jing Xiong; Zeyang Xia; Yangzhou Gan

    2016-08-01

    Clinical Application of linear percutaneous needle insertion is restricted due to issues such as limited path and deflection. Thus steering of flexible needle is critical demanded in the clinic. Previous studies tended to use autonomous methods to conduct path planning for needle steering. However, these methods had very limited adaptabilities, and they also decreased the human operator's domination of the operation, as clinically required. In this case, teleoperation has been an option, while in complicated environments sole teleoperation is not sufficient for a human operator to generate multi-curved insertion path. Therefore, in this paper, we propose a semiautonomous human-robot collaborated path planning method for teleoperated bevel-tip needle steering. The key module of this method is a human-robot collaboration mechanism which consists of the operator input, environment constraints, and path constraints. The proposed method were tested semi-physically in a simulated human environment and the results validated that the proposed method were able to efficiently assist the operator to generate multi-curved paths under human operator's domination.

  14. Single amino acid substitutions on the needle tip protein IpaD increased Shigella virulence.

    Science.gov (United States)

    Meghraoui, Alaeddine; Schiavolin, Lionel; Allaoui, Abdelmounaaïm

    2014-07-01

    Infection of colonic epithelial cells by Shigella is associated with the type III secretion system, which serves as a molecular syringe to inject effectors into host cells. This system includes an extracellular needle used as a conduit for secreted proteins. Two of these proteins, IpaB and IpaD, dock at the needle tip to control secretion and are also involved in the insertion of a translocation pore into host cell membrane allowing effector delivery. To better understand the function of IpaD, we substituted thirteen residues conserved among homologous proteins in other bacterial species. Generated variants were tested for their ability to surface expose IpaB and IpaD, to control secretion, to insert the translocation pore, and to invade host cells. In addition to a first group of seven ipaD variants that behaved similarly to the wild-type strain, we identified a second group with mutations V314D and I319D that deregulated secretion of all effectors, but remained fully invasive. Moreover, we identified a third group with mutations Y153A, T161D, Q165L and Y276A, that exhibited increased levels of translocators secretion, pore formation, and cell entry. Altogether, our results offer a better understanding of the role of IpaD in the control of Shigella virulence. Copyright © 2014 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  15. Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

    Energy Technology Data Exchange (ETDEWEB)

    Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego; Angelino, Valeria; Priola, Adriano M. [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Novello, Silvia [University of Torino, Department of Oncology, San Luigi Gonzaga Hospital (Italy); Barba, Matteo [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Gatti, Gaia; Righi, Luisella [University of Torino, Department of Pathology, San Luigi Gonzaga Hospital (Italy)

    2017-06-15

    PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

  16. Short beveled sharp cutting needle is superior to facet tip needle for ultrasound-guided rectus sheath block in children with umbilical hernia: a case series.

    Science.gov (United States)

    Alsaeed, A; Thallaj, A; Alzahrani, T; Khalil, N; Aljazaeri, A

    2014-10-01

    The most common peripheral nerve blocks used in umbilical hernia repair are rectus sheath block and regional block (caudal block). Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this study is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery, and to evaluate the easiness of soft tissue puncture and ultrasonic appearance of two different needle types. Twenty two (22) pediatric patients (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz linear probe. An ultrasound-guided rectus sheath block in the lateral edge of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). A 22 gauge short beveled sharp cutting needle 1.1 x 30 mm needle A (BD Insyte--W, Vialon material. Spain) was used in one side, and a Stimuplex A insulated Needle 22G 50mm (needle B) was used on the other side. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia were evaluated. Ultrasonograghic visualization of the posterior sheath was possible in all patients. Needle A scored 72.7% of excellent needle tip and shaft view (16 out of 22) compared to 63.63% for needle B (14 out of 22). None of the needles scored poor view. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one child who postoperatively requested morphine 0.1 mg/kg intravenously in recovery room. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia in the lateral edge of the rectus muscle. Use of the sharp short beveled needle of 22 gauge intravenous (IV) cannula stylet provides easy, less traumatic skin and rectus muscle

  17. [Evaluation of tip location reliability of intraprocedural ECG vs. chest Xrays in PICC placement].

    Science.gov (United States)

    Elli, Stefano; Cannizzo, Luigi; Marini, Alessia; Porcarelli, Silvia; Azzarone, Filippo; Fumagalli, Roberto; Foti, Giuseppe; Lucchini, Alberto

    2016-01-01

    . Evaluation of tip location reliability of intraprocedural ECG vs. chest Xrays in PICC placement. Among the methods to assess the correct positioning of the tip of central venous catheters, the ECG method is safe and reliable. To compare the reliability of tip location by intraprocedural ECG and post-procedural radiological examination as implemented in routine care in a tertiary hospital PICC Team. 119 PICCs positioned by the Monza hospital PICC Team were examined positioned by either ECG technique or post procedural x-rays technique. The tip location was assessed in retrospect, through occasional chest ray reports. We assessed the reliability of the ECG and X rays techniques. In the ECG group (75 catheters), 71 (95.7%) were correctly located vs 33/44 (75%) in the x-rays group. Tip location by ECG technique implemented by the PICC team is feasible and safe. The cost/benefit ratio suggests its adoption as main tip location technique.

  18. Flexible needle steering for percutaneous therapies.

    Science.gov (United States)

    Glozman, Daniel; Shoham, Moshe

    2006-07-01

    A robotic system is presented for flexible needle steering and control in soft tissue. Flexible needle insertion into a deformable tissue is modeled as a linear beam supported by virtual springs, where the stiffness coefficients of the springs can vary along the needle. Using this simplified model, the forward and inverse kinematics of the needle are solved analytically, thus enabling both path planning and path correction in real time. Given target and obstacle locations, the computer calculates the needle tip trajectory that will avoid the obstacle and hit the target. Using the inverse kinematics algorithm, the corresponding needle base maneuver needed to follow this trajectory is calculated. It is demonstrated that the needle tip path is not unique and can be optimized to minimize lateral pressure of the needle body on the tissue. Needle steering, i.e., the needle base movements that steer the needle tip, is not intuitive. Therefore, the needle insertion procedure is best performed by a robot. The model was verified experimentally on muscle and liver tissues by robotically assisted insertion of a flexible spinal needle. During insertion, the position and shape of the needle were recorded by X-ray. This study demonstrates the ability to curve a flexible needle by its base motion in order to achieve a planned tip trajectory.

  19. Multi-functional characteristics of the Pseudomonas aeruginosa type III needle-tip protein, PcrV; comparison to orthologs in other gram negative bacteria

    Directory of Open Access Journals (Sweden)

    Hiromi eSato

    2011-07-01

    Full Text Available Pseudomonas aeruginosa possesses a type III secretion system (T3SS to intoxicate host cells and evade innate immunity. This virulence-related machinery consists of a molecular syringe and needle assembled on the bacterial surface, which allows delivery of T3 effector proteins into infected cells. To accomplish a one-step effector translocation, a tip protein is required at the top end of the T3 needle structure. Strains lacking expression of the functional tip protein fail to intoxicate host cells.P. aeruginosa encodes a T3S that is highly homologous to the proteins encoded by Yersinia species. The needle tip proteins of Yersinia, LcrV, and P. aeruginosa, PcrV, share 37% identity and 65% similarity. Other known tip proteins are AcrV (Aeromonas, IpaD (Shigella, SipD (Salmonella, BipD (Burkholderia, EspA (EPEC, EHEC, Bsp22 (Bordetella, with additional proteins identified from various Gram negative species, such as Vibrio and Bordetella. The tip proteins can serve as a protective antigen or may be critical for sensing host cells and evading innate immune responses. Recognition of the host microenvironment transcriptionally activates synthesis of T3SS components. The machinery appears to be mechanically controlled by the assemblage of specific junctions within the apparatus. These junctions include the tip and base of the T3 apparatus, the needle proteins and components within the bacterial cytoplasm. The tip proteins likely have chaperone functions for translocon proteins, allowing the proper assembly of translocation channels in the host membrane and completing vectorial delivery of effector proteins into the host cytoplasm. Multifunctional features of the needle-tip proteins appear to be intricately controlled. In this review, we highlight the functional aspects and complex controls of T3 needle-tip proteins with particular emphasis on PcrV and LcrV.

  20. Influence of arm movement on central tip location of peripherally inserted central catheters (PICCs)

    International Nuclear Information System (INIS)

    Connolly, Bairbre; Amaral, Joao; Walsh, Sharon; Temple, Michael; Chait, Peter; Stephens, Derek

    2006-01-01

    PICCs are increasingly employed in children. Some of their risks relate to the location of the central tip. Despite care when placing lines, they sometimes move. To evaluate the influence of arm movement on the central tip location of PICCs placed in children. The central tip location of PICCs was studied in 85 children, with the arm placed in six positions. The variables of side, vein, site and arm position were examined to measure the direction and range of tip movement. The side, site or vein used did not influence the range of movement of the central tip. Change in position of the arm had a significant influence on the central tip location, moving it an average of 2.2 rib spaces, a maximum of 3.5 ribs. Elbow bending and adduction of the arm caused the central tip to move deeper into the chest, compared to when the arm was straight and abducted 90 . Arm position is the significant variable influencing PICC movement. Side, site and vein do not influence the range of movement significantly. Most PICCs descend deeper into the chest with arm adduction and elbow bending. (orig.)

  1. Influence of arm movement on central tip location of peripherally inserted central catheters (PICCs)

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, Bairbre; Amaral, Joao; Walsh, Sharon; Temple, Michael; Chait, Peter [University of Toronto, Image Guided Therapy, Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON (Canada); Stephens, Derek [University of Toronto, Population Health Sciences, The Hospital for Sick Children, Toronto, Ontario (Canada)

    2006-08-15

    PICCs are increasingly employed in children. Some of their risks relate to the location of the central tip. Despite care when placing lines, they sometimes move. To evaluate the influence of arm movement on the central tip location of PICCs placed in children. The central tip location of PICCs was studied in 85 children, with the arm placed in six positions. The variables of side, vein, site and arm position were examined to measure the direction and range of tip movement. The side, site or vein used did not influence the range of movement of the central tip. Change in position of the arm had a significant influence on the central tip location, moving it an average of 2.2 rib spaces, a maximum of 3.5 ribs. Elbow bending and adduction of the arm caused the central tip to move deeper into the chest, compared to when the arm was straight and abducted 90 . Arm position is the significant variable influencing PICC movement. Side, site and vein do not influence the range of movement significantly. Most PICCs descend deeper into the chest with arm adduction and elbow bending. (orig.)

  2. Novel pulsatile cerebrospinal fluid model to assess pressure manometry and fluid sampling through spinal needles of different gauge: support for the use of a 22 G spinal needle with a tapered 27 G pencil-point tip.

    Science.gov (United States)

    Ginosar, Y; Smith, Y; Ben-Hur, T; Lovett, J M; Clements, T; Ginosar, Y D; Davidson, E M

    2012-02-01

    Parallel-walled spinal needles ≤ 22 G are routinely used for lumbar puncture, despite a reported ≥ 32% incidence of post-dural puncture headache. A tapered spinal needle (22 G shaft, 27 G tip) is in use in our institution. We hypothesized that despite the smaller dural puncture hole, this needle has similar cerebrospinal fluid (CSF) pressure equilibration times and CSF sampling times to a standard 22 G needle and assessed a range of spinal needles using an experimental pulsatile CSF reservoir. The pulsatile CSF reservoir had an oscillating pressure varying between 25 and 15 cm H(2)O at a cycle frequency of 80 s(-1). We tested seven parallel-walled spinal needles (18-27 G) and the tapered 22/27 G needle. CSF pressure was measured every 2 s by manometry. The time to collect 1 ml CSF samples was measured. Saline 0.9% and mannitol 20% were tested separately. One-way ANOVA with Bonferroni post-hoc test was used to compare 22G, 27G and 22/27G needles. The mean [standard deviation (sd)] CSF pressure equilibration time (saline) was 40.7 (6.4), 108.7 (6.1), and 51.3 (4.6) s for the 22, 27, and 22/27 G needles (P< 0.0001 for comparisons between 27 G and other needles). The mean (sd) CSF sampling time (saline) was 40.3 (3.1), 225.3 (10.0), and 63.0 (5.2) s for the 22, 27, and 22/27 G needles (P< 0.0001 for comparisons between 27 G and other needles, and P= 0.019 between 22 and 22/27 G needles). Saline was different from mannitol for both measurements and all needles (P< 0.0001). A 22/27 G tapered spinal needle has similar flow properties to the 22 G needle, despite a 27 G tip.

  3. Force-Sensor-Based Estimation of Needle Tip Deflection in Brachytherapy

    Directory of Open Access Journals (Sweden)

    Thomas Lehmann

    2013-01-01

    in real time during needle insertion is the main contribution of this paper. The proposed approach solely relies on the measured forces and torques without a need for any other invasive/noninvasive sensing devices. A few mechanical models have been introduced previously regarding the way the forces are composed along the needle during insertion; we will compare our model to those approaches in terms of accuracy. In order to conduct experiments to verify the deflection model, a custom-built, 2-DOF robotic system for needle insertion is developed and discussed. This system is a prototype of an intelligent, hand-held surgical assistant tool that incorporates the virtual sensor proposed in this paper.

  4. Apical pressure and extent of irrigant flow beyond the needle tip during positive-pressure irrigation in an in vitro root canal model.

    Science.gov (United States)

    Park, Ellen; Shen, Ya; Khakpour, Mehrzad; Haapasalo, Markus

    2013-04-01

    This study aimed to measure the pressure generated during positive-pressure irrigation at the periapex of an in vitro tooth model using a novel method of measurement, investigating the effect of flow rate and needle design. Apical pressure was correlated with the extent of dye clearance from the end of a needle tip in a plastic root canal model with similar dimensions. The mesiobuccal canal of a mandibular molar was instrumented to #35/06 and placed into a chamber coupled to a pressure transducer. Irrigation was performed using a digital peristaltic pump using flow rates from 1-15 mL/min with irrigation needles of different sizes and designs. A plastic root canal model instrumented to the same size filled with dye was used to measure the extent of dye clearance beyond the needle tip using the same irrigation conditions. Positive-pressure irrigation revealed a flow rate-dependent increase in apical pressure (P irrigation flow rates was several times higher than at low flow rates. Needle designs with safety features yielded statistically significant lower apical pressures than needles without safety features (P model at flow rates higher than 4 mL/min. If apical clearance of dye beyond the needle tip is a measure of irrigation effectiveness, then maximum effectiveness with safe apical pressures can be gained at specific flow rates using specific needle tip designs. The use of an irrigation flow rate of 4 mL/min was able to achieve maximum effectiveness in this study. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Needle Tip Position and Bevel Direction Have No Effect in the Fluoroscopic Epidural Spreading Pattern in Caudal Epidural Injections: A Randomized Trial

    Directory of Open Access Journals (Sweden)

    Won Kyoung Kwon

    2016-01-01

    Full Text Available Background. Caudal epidural steroid injections (CESIs are an effective treatment for pain. If the injection spreads in a specific pattern depending on the needle position or bevel direction, it would be possible to inject the agent into a specific and desired area. Objectives. We conducted a prospective randomized trial to determine if the needle position and bevel direction have any effect on the epidural spreading pattern in CESI. Methods. Demographic data of the patient were collected. During CESI, the needle position (middle or lateral and direction (ventral or dorsal were randomly allocated. Following fluoroscope-guided injection of 4 mL contrast media and 10 mL of injectates, the epidural spreading patterns (ventral or dorsal, bilateral or lateral were imaged. Results. In the 210 CESIs performed, the needle tip position and bevel direction did not influence the epidural spreading patterns at L4-5 and L5-S1 disc levels. A history of Lumbar spine surgery was associated with a significantly limited spread to each disc level. A midline needle tip position was more effective than the lateral position in spreading to the distant disc levels. Conclusions. Neither the needle tip position nor the bevel direction affected the epidural drug spreading pattern during CESI.

  6. Shigella IpaD has a dual role: signal transduction from the type III secretion system needle tip and intracellular secretion regulation.

    Science.gov (United States)

    Roehrich, A Dorothea; Guillossou, Enora; Blocker, Ariel J; Martinez-Argudo, Isabel

    2013-02-01

    Type III secretion systems (T3SSs) are protein injection devices essential for the interaction of many Gram-negative bacteria with eukaryotic cells. While Shigella assembles its T3SS when the environmental conditions are appropriate for invasion, secretion is only activated after physical contact with a host cell. First, the translocators are secreted to form a pore in the host cell membrane, followed by effectors which manipulate the host cell. Secretion activation is tightly controlled by conserved T3SS components: the needle tip proteins IpaD and IpaB, the needle itself and the intracellular gatekeeper protein MxiC. To further characterize the role of IpaD during activation, we combined random mutagenesis with a genetic screen to identify ipaD mutant strains unable to respond to host cell contact. Class II mutants have an overall defect in secretion induction. They map to IpaD's C-terminal helix and likely affect activation signal generation or transmission. The Class I mutant secretes translocators prematurely and is specifically defective in IpaD secretion upon activation. A phenotypically equivalent mutant was found in mxiC. We show that IpaD and MxiC act in the same intracellular pathway. In summary, we demonstrate that IpaD has a dual role and acts at two distinct locations during secretion activation. © 2013 Blackwell Publishing Ltd.

  7. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  8. Förster Resonance Energy Transfer (FRET as a Tool for Dissecting the Molecular Mechanisms for Maturation of the Shigella Type III Secretion Needle Tip Complex

    Directory of Open Access Journals (Sweden)

    William D. Picking

    2012-11-01

    Full Text Available Förster resonance energy transfer (FRET provides a powerful tool for monitoring intermolecular interactions and a sensitive technique for studying Å-level protein conformational changes. One system that has particularly benefited from the sensitivity and diversity of FRET measurements is the maturation of the Shigella type III secretion apparatus (T3SA needle tip complex. The Shigella T3SA delivers effector proteins into intestinal cells to promote bacterial invasion and spread. The T3SA is comprised of a basal body that spans the bacterial envelope and a needle with an exposed tip complex that matures in response to environmental stimuli. FRET measurements demonstrated bile salt binding by the nascent needle tip protein IpaD and also mapped resulting structural changes which led to the recruitment of the translocator IpaB. At the needle tip IpaB acts as a sensor for host cell contact but prior to secretion, it is stored as a heterodimeric complex with the chaperone IpgC. FRET analyses showed that chaperone binding to IpaB’s N-terminal domain causes a conformational change in the latter. These FRET analyses, with other biophysical methods, have been central to understanding T3SA maturation and will be highlighted, focusing on the details of the FRET measurements and the relevance to this particular system.

  9. Comparing the outcomes of incisions made by colorado microdissection needle, electrosurgery tip, and surgical blade during periodontal surgery: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Rampalli Viswa Chandra

    2016-01-01

    Full Text Available Context: Electrosurgery offers many unique advantages such as hemostasis and precise tissue cutting; however, there are a number of disadvantages including thermal injury and delayed wound healing. Aims: The aim of the present study was to compare the outcomes of incisions made by Colorado® microdissection needle, electrosurgery tip, and surgical blade during periodontal surgery. Settings and Design: Twenty-two individuals participated in this study. Three quadrants in each individual were randomly assigned into each of the following experimental groups: Colorado® microdissection needle (CMD, electrosurgery tip (EC and surgical blade (BP, in which, incisions were given with Colorado® microdissection needle, straight electrocautery tip, and a scalpel blade, respectively. Materials and Methods: Blood loss (BL was measured immediately after surgery, and changes in interdental papilla dimensions were recorded at baseline, 7, 30, 120, and 180 days after surgery. Measures of periodontal disease were recorded at baseline, 120, and 180 days after surgery. Postoperative pain and wound healing were recorded at 1, 7, and 15 days after surgery. Results: The use of CMD for periodontal surgery showed better results over EC in all parameters. CMD resulted in lesser bleeding and less postoperative pain and attained similar results to that of BP in clinical parameters of periodontal disease. Conclusions: Colorado® microdissection needle may be a better choice for incisions as it seems to show less tissue damage than cautery and offers tissue healing comparable to scalpel blade.

  10. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  11. Mechanics-Based Model for Predicting In-Plane Needle Deflection with Multiple Bends

    NARCIS (Netherlands)

    Roesthuis, Roy; Abayazid, Momen; Misra, Sarthak

    2012-01-01

    Bevel-tipped flexible needles naturally bend when inserted into soft tissue. Steering such needles along curved paths allows one to avoid anatomical obstacles and reach locations inside the human body which are unreachable with rigid needles. In this study, a mechanics-based model is presented which

  12. The use of a Colapinto TIPS Needle under cone-beam computed tomography guidance for true lumen re-entry in subintimal recanalization of chronic iliac artery occlusion.

    Science.gov (United States)

    Liang, Huei-Lung; Li, Ming-Feng; Chiang, Chia-Ling; Chen, Matt Chiung-Yu; Wu, Chieh-Jen; Pan, Huay-Ben

    2017-06-01

    To report the technique and clinical outcome of subintimal re-entry in chronic iliac artery occlusion by using a Colapinto transjugular intrahepatic portosystemic shunt (TIPS) needle under rotational angiography (cone-beam computed tomography; CT) imaging guidance. Patients with chronic iliac artery occlusion with earlier failed attempts at conventional percutaneous recanalization during the past 5 years were enrolled in our study. In these patients, an ipsilateral femoral access route was routinely utilized in a retrograde fashion. A Colapinto TIPS Needle was used to aid the true lumen re-entry after failed conventional intraluminal or subintimal guidewire and catheter-based techniques. The puncture was directed under rotational angiography cone-beam CT guidance to re-enter the abdominal aorta. Bare metallic stents 8-10 mm in diameter were deployed in the common iliac artery, and followed by balloon dilation. Ten patients (9 male; median age, 75 years) were included in our investigation. The average occlusion length was 10.2 cm (range, 4-15 cm). According to the Trans-Atlantic Inter-Society Consensus (TASC) II classification, there were five patients each with Class B and D lesions. Successful re-entry was achieved in all patients without procedure-related complications. The ankle-brachial index (ABI) values increased from 0.38-0.79 to 0.75-1.28 after the procedure. Imaging follow-up (> 6 months) was available in six patients with patency of all stented iliac artery. Thereafter, no complaints of recurrent clinical symptoms occurred during the follow-up period. The use of Colapinto TIPS needle, especially under cone-beam CT image guidance, appears to be safe and effective to re-enter the true lumen in a subintimal angioplasty for a difficult chronic total iliac occlusion. Copyright © 2017. Published by Elsevier Taiwan LLC.

  13. Semi-Automated Needle Steering in Biological Tissue Using an Ultrasound-Based Deflection Predictor.

    Science.gov (United States)

    Khadem, Mohsen; Rossa, Carlos; Usmani, Nawaid; Sloboda, Ron S; Tavakoli, Mahdi

    2017-04-01

    The performance of needle-based interventions depends on the accuracy of needle tip positioning. Here, a novel needle steering strategy is proposed that enhances accuracy of needle steering. In our approach the surgeon is in charge of needle insertion to ensure the safety of operation, while the needle tip bevel location is robotically controlled to minimize the targeting error. The system has two main components: (1) a real-time predictor for estimating future needle deflection as it is steered inside soft tissue, and (2) an online motion planner that calculates control decisions and steers the needle toward the target by iterative optimization of the needle deflection predictions. The predictor uses the ultrasound-based curvature information to estimate the needle deflection. Given the specification of anatomical obstacles and a target from preoperative images, the motion planner uses the deflection predictions to estimate control actions, i.e., the depth(s) at which the needle should be rotated to reach the target. Ex-vivo needle insertions are performed with and without obstacle to validate our approach. The results demonstrate the needle steering strategy guides the needle to the targets with a maximum error of 1.22 mm.

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the portal system using a TIPS needle (a special long needle extending from the neck into the ... Encephalopathy can be treated with certain medications, a special diet or, by revising the stent, but sometimes ...

  15. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  16. Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle.

    Science.gov (United States)

    Elayaperumal, Santhi; Plata, Juan Camilo; Holbrook, Andrew B; Park, Yong-Lae; Pauly, Kim Butts; Daniel, Bruce L; Cutkosky, Mark R

    2014-11-01

    This study demonstrates real-time scan plane control dependent on three-dimensional needle bending, as measured from magnetic resonance imaging (MRI)-compatible optical strain sensors. A biopsy needle with embedded fiber Bragg grating (FBG) sensors to measure surface strains is used to estimate its full 3-D shape and control the imaging plane of an MR scanner in real-time, based on the needle's estimated profile. The needle and scanner coordinate frames are registered to each other via miniature radio-frequency (RF) tracking coils, and the scan planes autonomously track the needle as it is deflected, keeping its tip in view. A 3-D needle annotation is superimposed over MR-images presented in a 3-D environment with the scanner's frame of reference. Scan planes calculated based on the FBG sensors successfully follow the tip of the needle. Experiments using the FBG sensors and RF coils to track the needle shape and location in real-time had an average root mean square error of 4.2 mm when comparing the estimated shape to the needle profile as seen in high resolution MR images. This positional variance is less than the image artifact caused by the needle in high resolution SPGR (spoiled gradient recalled) images. Optical fiber strain sensors can estimate a needle's profile in real-time and be used for MRI scan plane control to potentially enable faster and more accurate physician response.

  17. ECG or X-ray as the 'gold standard' for establishing PICC-tip location?

    Science.gov (United States)

    Oliver, Gemma; Jones, Matt

    2014-10-22

    Recently there has been an increase in evidence that the tip position of a peripherally inserted central catheter (PICC) needs to be accurately placed in the lower third of the superior vena cava at the junction with the right atrium in order to minimise potential complications ( Royal College of Nursing, 2010 ; Infusion Nurses Society, 2011 ). The current 'gold standard' practice of performing a chest X-ray post-insertion of PICC can be fraught with complications with regard to accurately placing the PICC in this position. The purpose of this evaluation is to discuss how using an electrocardiogram-guided PICC placement system may be a preferable method with which to accurately measure the exact position of the PICC within the venous system.

  18. Study on the Effect of the Impact Location and the Type of Hammer Tip on the Frequency Response Function (FRF) in Experimental Modal Analysis of Rectangular Plates

    Science.gov (United States)

    Mali, K. D.; Singru, P. M.

    2018-03-01

    In this work effect of the impact location and the type of hammer tip on the frequency response function (FRF) is studied. Experimental modal analysis of rectangular plates is carried out for this purpose by using impact hammer, accelerometer and fast Fourier transform (FFT) analyzer. It is observed that the impulse hammer hit location has, no effect on the eigenfrequency, yet a difference in amplitude of the eigenfrequencies is obtained. The effect of the hammer tip on the pulse and the force spectrum is studied for three types of tips metal, plastic and rubber. A solid rectangular plate was excited by using these tips one by one in three different tests. It is observed that for present experimental set up plastic tip excites the useful frequency range.

  19. High Opening Injection Pressure Is Associated With Needle-Nerve and Needle-Fascia Contact During Femoral Nerve Block.

    Science.gov (United States)

    Gadsden, Jeff; Latmore, Malikah; Levine, D Matt; Robinson, Allegra

    2016-01-01

    High opening injection pressures (OIPs) have been shown to predict sustained needle tip contact with the roots of the brachial plexus. Such roots have a uniquely high ratio of fascicular versus connective tissue. It is unknown if this relationship is preserved during multifascicular nerve blockade. We hypothesized that OIP can predict needle-nerve contact during femoral nerve block, as well as detect needle contact with the fascia iliaca. Twenty adults scheduled for femoral block were recruited. Using ultrasound, a 22-gauge needle was sequentially placed in 4 locations: indenting the fascia iliaca, advanced through the fascia iliaca while lateral to the nerve, slightly indenting the femoral nerve, and withdrawn from the nerve 1 mm. At each location, the OIP required to initiate an injection of 1 mL D5W (5% dextrose in water) at 10 mL/min was recorded. Blinded investigators performed evaluations and aborted injections when an OIP of 15 psi was reached. Opening injection pressure was 15 psi or greater for 90% and 100% of cases when the needle indented the femoral nerve and fascia iliaca, respectively. Opening injection pressure was less than 15 psi for all 20 patients when the needle was withdrawn 1 mm from the nerve as well as at the subfascial position (McNemar χ2 P fascia iliaca (100%). Needle tip positions not indenting these structures were associated with OIP of less than 15 psi (100%).

  20. A Bayesian Approach to Locating the Red Giant Branch Tip Magnitude. I.

    Science.gov (United States)

    Conn, A. R.; Lewis, G. F.; Ibata, R. A.; Parker, Q. A.; Zucker, D. B.; McConnachie, A. W.; Martin, N. F.; Irwin, M. J.; Tanvir, N.; Fardal, M. A.; Ferguson, A. M. N.

    2011-10-01

    We present a new approach for identifying the tip of the red giant branch (TRGB) which, as we show, works robustly even on sparsely populated targets. Moreover, the approach is highly adaptable to the available data for the stellar population under study, with prior information readily incorporable into the algorithm. The uncertainty in the derived distances is also made tangible and easily calculable from posterior probability distributions. We provide an outline of the development of the algorithm and present the results of tests designed to characterize its capabilities and limitations. We then apply the new algorithm to three M31 satellites: Andromeda I, Andromeda II, and the fainter Andromeda XXIII, using data from the Pan-Andromeda Archaeological Survey (PAndAS), and derive their distances as 731(+ 5) + 18 (- 4) - 17 kpc, 634(+ 2) + 15 (- 2) - 14 kpc, and 733(+ 13) + 23 (- 11) - 22 kpc, respectively, where the errors appearing in parentheses are the components intrinsic to the method, while the larger values give the errors after accounting for additional sources of error. These results agree well with the best distance determinations in the literature and provide the smallest uncertainties to date. This paper is an introduction to the workings and capabilities of our new approach in its basic form, while a follow-up paper shall make full use of the method's ability to incorporate priors and use the resulting algorithm to systematically obtain distances to all of M31's satellites identifiable in the PAndAS survey area.

  1. A BAYESIAN APPROACH TO LOCATING THE RED GIANT BRANCH TIP MAGNITUDE. I

    International Nuclear Information System (INIS)

    Conn, A. R.; Parker, Q. A.; Zucker, D. B.; Lewis, G. F.; Ibata, R. A.; McConnachie, A. W.; Martin, N. F.; Irwin, M. J.; Tanvir, N.; Fardal, M. A.; Ferguson, A. M. N.

    2011-01-01

    We present a new approach for identifying the tip of the red giant branch (TRGB) which, as we show, works robustly even on sparsely populated targets. Moreover, the approach is highly adaptable to the available data for the stellar population under study, with prior information readily incorporable into the algorithm. The uncertainty in the derived distances is also made tangible and easily calculable from posterior probability distributions. We provide an outline of the development of the algorithm and present the results of tests designed to characterize its capabilities and limitations. We then apply the new algorithm to three M31 satellites: Andromeda I, Andromeda II, and the fainter Andromeda XXIII, using data from the Pan-Andromeda Archaeological Survey (PAndAS), and derive their distances as 731 (+5)+18 (-4)-17 kpc, 634 (+2)+15 (-2)-14 kpc, and 733 (+13)+23 (-11)-22 kpc, respectively, where the errors appearing in parentheses are the components intrinsic to the method, while the larger values give the errors after accounting for additional sources of error. These results agree well with the best distance determinations in the literature and provide the smallest uncertainties to date. This paper is an introduction to the workings and capabilities of our new approach in its basic form, while a follow-up paper shall make full use of the method's ability to incorporate priors and use the resulting algorithm to systematically obtain distances to all of M31's satellites identifiable in the PAndAS survey area.

  2. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E. [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT (United Kingdom); Mari, Jean Martial [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom and GePaSud, University of French Polynesia, Faa’a 98702, French Polynesia (France); West, Simeon J. [Department of Anaesthesia, University College Hospital, Main Theatres, Maple Bridge Link Corridor, Podium 3, 235 Euston Road, London NW1 2BU (United Kingdom); Ginsberg, Yuval; David, Anna L. [Institute for Women’s Health, University College London, 86-96 Chenies Mews, London WC1E 6HX (United Kingdom); Ourselin, Sebastien [Center for Medical Imaging Computing, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2015-10-15

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction with the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With

  3. Carbon fibre and nitinol needles for MRI-guided interventions: First in vitro and in vivo application

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Christoph, E-mail: Christoph.thomas@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Wojtczyk, Hanne [Section of Experimental Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Rempp, Hansjoerg; Clasen, Stephan; Horger, Marius [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Lassberg, Christoph von [Department of Sports Medicine, University of Tuebingen, Silcherstrasse 5, 72076 Tuebingen (Germany); Fritz, Jan [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 600 North Wolfe Street, Baltimore, MD 21287 (United States); Claussen, Claus D. [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Pereira, Philippe L. [Department of Radiology, Minimally Invasive Therapies and Nuclearmedicine, SLK-Kliniken Heilbronn GmbH, Am Gesundbrunnen 20-26, 74078 Heilbronn (Germany)

    2011-09-15

    Objective: To assess the artefact properties of a MR-compatible carbon fibre needle with a nitinol mandrin in vitro and to report first clinical experiences. Materials and methods: In vitro, the carbon fibre/nitinol needle was imaged at different angles against the main magnetic field (1.5 T open bore magnet). A gradient echo MR fluoroscopy sequence (GRE: TR 9.3 ms, TE 3.12 ms, bandwidth 200 Hz/pixel, flip-angle 12{sup o}) and a fast turbo spin echo sequence (FSE: TR 412 ms, TE 9.7 ms, bandwidth 200 Hz/pixel, flip-angle 150{sup o}) were used. Artefact width, needle intensity contrast and needle tip location errors were assessed. In vivo, lumbar periradicular corticosteroid injections and one sclerotherapy were performed with carbon fibre needles (10 procedures) and with titanium alloy needles (2 procedures). The artefact sizes and contrasts were measured. Results: In vitro, artefact diameters of the carbon fibre needle ranged from 3.3 to 4.6 mm, contrasts from 0.11 to 0.52, with larger artefact contrasts and widths with the GRE sequence. Needle tip location errors of -2.1 to -2.8 mm were observed. Decreasing angles to the main field lead to smaller artefacts. In vivo, the carbon fibre/nitinol needle produced smaller artefacts (mean width FSE/GRE: 2.8 mm/4.6 mm) with lower contrast (0.30-0.42) than the titanium alloy needle (mean width FSE/GRE: 4.1 mm/7.5 mm, contrast 0.60-0.73). Conclusions: The carbon fibre/nitinol needle is useful for performing MR-guided interventions at 1.5 T, producing more subtle artefacts than a titanium alloy needle, but with an incomplete depiction and thus inaccurate localization of the needle tip.

  4. Use of real-time ultrasound for locating tip position in neonates undergoing peripherally inserted central catheter insertion: A pilot study

    Science.gov (United States)

    Telang, Nagsen; Sharma, Deepak; Pratap, Oleti Tejo; Kandraju, Hemasree; Murki, Srinivas

    2017-01-01

    Background & objectives: Securing long-term venous access is an essential part of sick newborn care. The malposition of central line tip leads to several complications. There is a need for an easily available bedside investigating tool to diagnose these malpositions. This study was done to compare the effectiveness of real-time ultrasound (RTUS) with X-ray in identifying the peripherally inserted central catheter (PICC) line tip. Methods: This pilot observational study was conducted in a level III Neonatal Intensive Care Unit of a tertiary care hospital in India, from June 2012 to June 2013. A total of 33 PICC lines in 31 infants were included in the study. After insertion of PICC line, X-ray and RTUS were done to locate the tip of the PICC line. Results: In this study, PICC line tip could be identified by bedside RTUS in 94 per cent of line insertions. Standard X-ray identified the tip in all cases. RTUS has been shown to have good diagnostic utility in comparison with X-ray with sensitivity and specificity being 96.55 and 100 per cent, respectively. In our study, majority of malpositions were identified and manipulated by RTUS, thus second X-rays were avoided. Interpretation & conclusions: The result of this pilot study shows that RTUS may be a reliable and safe bedside tool for determining the tip of PICC lines. However, studies with large sample size need to be done to confirm these findings. PMID:28749401

  5. Sugar export limits size of conifer needles

    DEFF Research Database (Denmark)

    Rademaker, Hanna; Zwieniecki, Maciej A.; Bohr, Tomas

    2017-01-01

    produced near the tip of long needles cannot be exported efficiently, because the pressure required to drive vascular flow would exceed the greatest available pressure (the osmotic pressure). This basic constraint leads to the formation of an inactive region of stagnant fluid near the needle tip, which...

  6. The effect of needle gauge, needle type, and needle orientation on the volume of a drop.

    Science.gov (United States)

    Tripp, Geneva K; Good, Kathryn L; Motta, Monica J; Kass, Philip H; Murphy, Christopher J

    2016-01-01

    The purpose of this study was to determine impact of needle gauge, type, and orientation on average volume of drop dispensed. Five needle gauges (22G, 23G, 25G, 27G, and 30G) were examined. For each gauge, volume of drop delivered was determined for standard sharp beveled tip, blunt tip, and after breaking off of the sharp needle from the hub. Vertical and horizontal orientation of the needle was tested for effect on drop volume for 22-G and 30-G sharp beveled needles. Mean drop volume was affected by needle gauge, needle orientation, and whether the needle had been broken off from its hub. Mean drop volume scaled directly with needle diameter with drop volumes of 25.0 μL (±20.2) and 83.9 μL (±16.5) being found for 30-gauge and 22-gauge needles, respectively. Intermediate gauges (27, 25, 23G) yielded intermediate drop volumes. Blunt needles tended to produce larger drop volumes compared to sharp beveled needles, but these differences did not reach statistical significance. Breaking off of the needle from the hub produced substantially larger drop volumes with little difference being found between needle gauges. Average volumes of 1 drop from a 22-G vertical, 22-G horizontal, 30-G vertical, and 30-G horizontal sharp beveled needle were 20.2, 9.1, 10.1, and 3.3 μL, respectively. These findings have relevance for controlled delivery of topical ophthalmic medications to patients. © 2015 American College of Veterinary Ophthalmologists.

  7. Robotically steering flexible needles

    NARCIS (Netherlands)

    Abayazid, Momen

    2015-01-01

    Needle insertion into soft tissue is one of the common minimally invasive surgical procedures. Many diagnostic and therapeutic clinical procedures require insertion of a needle to a specific location in soft-tissue, including biopsy or radioactive seed implantation for cancer treatment

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... deeply you are sedated. When the needle is advanced through the liver and the pathway is expanded ... are the limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening ...

  9. Towards quantitative off-axis electron holographic mapping of the electric field around the tip of a sharp biased metallic needle

    DEFF Research Database (Denmark)

    Beleggia, Marco; Kasama, Takeshi; Larson, D. J.

    2014-01-01

    We apply off-axis electron holography and Lorentz microscopy in the transmission electron microscope to map the electric field generated by a sharp biased metallic tip. A combination of experimental data and modelling provides quantitative information about the potential and the field around the ...

  10. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  11. Fundamental Study of a Single Point Lean Direct Injector. Part I: Effect of Air Swirler Angle and Injector Tip Location on Spray Characteristics

    Science.gov (United States)

    Tedder, Sarah A.; Hicks, Yolanda R.; Tacina, Kathleen M.; Anderson, Robert C.

    2015-01-01

    Lean direct injection (LDI) is a combustion concept to reduce oxides of nitrogen (NOx) for next generation aircraft gas turbine engines. These newer engines have cycles that increase fuel efficiency through increased operating pressures, which increase combustor inlet temperatures. NOx formation rates increase with higher temperatures; the LDI strategy avoids high temperature by staying fuel lean and away from stoichiometric burning. Thus, LDI relies on rapid and uniform fuel/air mixing. To understand this mixing process, a series of fundamental experiments are underway in the Combustion and Dynamics Facility at NASA Glenn Research Center. This first set of experiments examines cold flow (non-combusting) mixing using air and water. Using laser diagnostics, the effects of air swirler angle and injector tip location on the spray distribution, recirculation zone, and droplet size distribution are examined. Of the three swirler angles examined, 60 degrees is determined to have the most even spray distribution. The injector tip location primarily shifts the flow without changing the structure, unless the flow includes a recirculation zone. When a recirculation zone is present, minimum axial velocity decreases as the injector tip moves downstream towards the venturi exit; also the droplets become more uniform in size and angular distribution.

  12. Remote Electromagnetic Vibration of Steerable Needles for Imaging in Power Doppler Ultrasound

    Science.gov (United States)

    Cabreros, Sarah S.; Jimenez, Nina M.; Greer, Joseph D.; Adebar, Troy K.; Okamura, Allison M.

    2015-01-01

    Robotic needle steering systems for minimally invasive medical procedures require complementary medical imaging systems to track the needles in real time. Ultrasound is a promising imaging modality because it offers relatively low-cost, real-time imaging of the needle. Previous methods applied vibration to the base of the needle using a voice coil actuator, in order to make the needle visible in power Doppler ultrasound. We propose a new method for needle tip vibration, using electromagnetic actuation of small permanent magnets placed inside the needle to improve needle tip visibility in power Doppler imaging. Robotic needle insertion experiments using artificial tissue and ex vivo porcine liver showed that the electromagnetic tip vibration method can generate a stronger Doppler response compared to the previous base vibration method, resulting in better imaging at greater needle depth in tissue. It also eliminates previous issues with vibration damping along the shaft of the needle. PMID:26413379

  13. [Percutaneous needle aponeurotomy for Dupuytren's disease].

    Science.gov (United States)

    Spies, C K; Müller, L P; Skouras, E; Bassemir, D; Hahn, P; Unglaub, F

    2016-02-01

    Percutaneous transverse aponeurotomy of the cord by using a hypodermic needle as a scalpel blade in order to improve function of the hand. Symptomatic flexion contracture with positive table top test caused by a single, palpable cord within the palm (primarily Tubiana stages I and II). Multiple, infiltrating or broad-based cords within the palm; irritated skin conditions; exclusive digital cord localization; recurrence after aponeurectomy; previous surgical intervention at the site of interest, digital nerve lesions; lack of patient compliance. Pinpoint surface anesthesia is obtained by injecting each portal area subdermally with 0.1 ml of local anesthetic. These applications start from distally to proximally within the palm while the most distal injection site is located proximal to the distal palm crease. Then the needle tip is introduced perpendicular to the cord. Sawing movements through the cord are performed transversely. While passively extending the contracted finger, the cord is held under tension which guarantees safe cutting. Patients are encouraged to report immediate pain sensation or numbness in order to prevent injuries to neurovascular structures and active finger flexion excludes tendon lesions during the procedure. Introducing the needle tip may be performed at several sites along the cord, if necessary, from distal to proximal at least 5 mm apart with prior pinpoint surface anesthesia. Finally, cautious passive stretching may be done after each release. Bandaging allowing immediate motion; application of a hand-based extension splint-glove during the night for 3-6 months. Recurrence rate was 53% in 15 retrospectively examined patients after a mean interval of 40 months postoperatively.

  14. Remembering tips

    Science.gov (United States)

    Memory aids; Alzheimer disease - remembering tips; Early memory loss - remembering tips; Dementia - remembering tips ... active: Read a lot if you have trouble remembering words. Keep a dictionary close by. Take part ...

  15. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  16. Driven Around the Bend: Novel Use of a Curved Steerable Needle

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Darra T., E-mail: darra.murphy@vch.ca; Korzan, Jeffrey R.; Ouellette, Hugue A.; Liu, David M. [Vancouver General Hospital, Department of Radiology (Canada); Clarkson, Paul W. [Vancouver General Hospital, Department of Orthopedic Surgery (Canada); Munk, Peter L. [Vancouver General Hospital, Department of Radiology (Canada)

    2013-04-15

    This technical note describes the novel use of a curved, steerable needle to access symptomatic osseous lesions in the pelvis and sacrum for palliative percutaneous treatment that would otherwise be difficult to treat using conventional straight needles. Seven patients with lytic bone lesions were treated. One patient had multiple myeloma; the remaining had metastatic disease: breast carcinoma (n = 2), colorectal carcinoma (n = 1), renal cell carcinoma (n = 1), squamous cell carcinoma (n = 1), and leiomyosarcoma (n = 1). Five of the seven patients had lesions in the posterior acetabulum, and the two other patients had lesions in the sacrum. Four of the seven patients received radiofrequency ablation followed by cementoplasty; three patients received cementation alone. We used a novel needle designed for vertebroplasty, which has an articulating tip allowing it to be guided into lytic bone lesions located in difficult-to-access regions of the pelvis and sacrum. All patients were successfully treated with cementoplasty either with or without thermal ablation. No serious adverse events were reported. The needle was difficult to withdraw in two patients. Steerable curved needles can be successfully used to treat lytic osseous metastases with cementoplasty when lesions are located in sites that may be difficult to reach using conventional straight needles.

  17. Design of an actively controlled steerable needle with tendon actuation and FBG-based shape sensing.

    Science.gov (United States)

    van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J

    2015-06-01

    This work presents a new steerable needle to facilitate active steering toward predefined target locations. It focuses on mechanical aspects and design choices in relation to the observed response in a tissue phantom. Tip steering with two rotational degrees of freedom was achieved by a tendon actuated ball joint mechanism. During insertion, the flexible cannula bends as a result of asymmetric tip-tissue interaction forces. The stylet was equipped with fiber Bragg gratings to measure the needle shape and tip position during use. A PI-controller was implemented to facilitate steering to predefined targets. During the validation study, nine targets were defined at a depth of 100 mm below the gelatin surface. One was located below the insertion point, the others at a radial offset of 30 mm in each of the eight principle steering directions. Per location, six repetitions were performed. The targeting accuracy was 6.2 ± 1.4 mm (mean ± std). The steering precision was 2.6 ± 1.1 mm. The ability to steer with this new needle steering approach is presented and the mechanical characteristics are discussed for this representative subset of steering directions. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Tips for TIPS

    NARCIS (Netherlands)

    Cuijpers, C.F.

    2015-01-01

    The transjugular intrahepatic portosystemic shunt (TIPS) procedure is one of the most technically challenging procedures in interventional radiology. During the procedure, interventional radiologists (IRs) insert very thin and long instruments through a little incision in the patient’s neck. They

  19. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  20. Smart surgical needle actuated by shape memory alloys for percutaneous procedures

    Science.gov (United States)

    Konh, Bardia

    feasibility of providing actuation forces using both SMAs and SMPs for the surgical needle was demonstrated in this study. The needle insertion simulation was validated while observing less than 10% deviation between the estimated amount of needle deflection by the simulation and by the experiments. Using this model the effect of needle diameter and its bevel tip angle on the final shape of the needle was investigated. Conclusion: The numerical and experimental studies of this work showed that a highly maneuverable active needle can be made using the actuation of multiple SMA wires in series. To maneuver around the anatomical obstacles of the human body and reach the target location, thin sharp needles are recommended as they would create a smaller radius of curvature. The insertion model presented in this work is intended to be used as a base structure for path planning and training purposes for future studies. (Abstract shortened by UMI.).

  1. Percutaneous radiofrequency treatment of osteoid osteoma using cool-tip electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain)]. E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain); Ortiz, Eduardo [Departamento de Cirugia ortopedica, Fundacion Hospital Alcorcon, Madrid (Spain)

    2005-12-15

    Objectives: To report our experience with percutaneous cool-tip radiofrequency ablation of osteoid osteomas and to evaluate clinical outcome. Methods and material: Forty-one patients with clinically and radiologically suspected osteoid osteoma were seen over a 48-month period (27 males and 14 females with a mean age of 18.7 years; range 5-43 years). Thirty-eight patients were treated by computed tomography (CT)-guided percutaneous radiofrequency ablation. The procedure was performed under regional or general anaesthesia. After location of the nidus, a 14G-bone biopsy needle is introduced into the nidus. Sampling is performed with a 17G-bone biopsy needle using a coaxial technique. The radiofrequency needle with a 10 mm active tip (cool-tip) is inserted through the biopsy needle and is connected to the radiofrequency generator for 6-8 min. Results: Primary success was obtained in 37 patients (97%) with a 100% secondary success rate. All patients are currently pain-free. No major complications occurred. Patients could resume unrestricted normal activity within 24 h. Conclusions: Percutaneous radiofrequency ablation of osteoid osteomas is an efficient and safe method that can be considered the procedure of choice for most cases.

  2. Tipping Point

    Medline Plus

    Full Text Available ... death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ... tv tip-overs. The force of a large television falling from tipping furniture can be staggering. A ...

  3. Use of real-time ultrasound for locating tip position in neonates undergoing peripherally inserted central catheter insertion: A pilot study

    Directory of Open Access Journals (Sweden)

    Nagsen Telang

    2017-01-01

    Interpretation & conclusions: The result of this pilot study shows that RTUS may be a reliable and safe bedside tool for determining the tip of PICC lines. However, studies with large sample size need to be done to confirm these findings.

  4. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  5. Accuracy of biopsy needle navigation using the Medarpa system - computed tomography reality superimposed on the site of intervention

    International Nuclear Information System (INIS)

    Khan, M. Fawad; Maataoui, Adel; Gurung, Jessen; Schiemann, Mirko; Vogl, Thomas J.; Dogan, Selami; Ackermann, Hanns; Wesarg, Stefan; Sakas, Georgios

    2005-01-01

    The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54-9.51 mm) and 7.05±1.33 mm for group B (range 4.10-9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique. (orig.)

  6. Ultrasonic Needles for Bone Biopsy.

    Science.gov (United States)

    Mathieson, Andrew; Wallace, Robert; Cleary, Rebecca; Li Li; Simpson, Hamish; Lucas, Margaret

    2017-02-01

    Bone biopsy is an invasive clinical procedure, where a bone sample is recovered for analysis during the diagnosis of a medical condition. When the architecture of the bone tissue is required to be preserved, a core-needle biopsy is taken. Although this procedure is performed while the patient is under local anaesthesia, the patient can still experience significant discomfort. Additionally, large haematoma can be induced in the soft tissue surrounding the biopsy site due to the large axial and rotational forces, which are applied through the needle to penetrate bone. It is well documented that power ultrasonic surgical devices offer the advantages of low cutting force, high accuracy, and preservation of soft tissues. This paper reports a study of the design, analysis, and test of two novel power ultrasonic needles for bone biopsy that operate using different configurations to penetrate bone. The first utilizes micrometric vibrations generated at the distil tip of a full-wavelength resonant ultrasonic device, while the second utilizes an ultrasonic-sonic approach, where vibrational energy generated by a resonant ultrasonic horn is transferred to a needle via the chaotic motion of a free-mass. It is shown that the dynamic behavior of the devices identified through experimental techniques closely match the behavior calculated through numerical and finite-element analysis methods, demonstrating that they are effective design tools for these devices. Both devices were able to recover trabecular bone from the metaphysis of an ovine femur, and the biopsy samples were found to be comparable to a sample extracted using a conventional biopsy needle. Furthermore, the resonant needle device was also able to extract a cortical bone sample from the central diaphysis, which is the strongest part of the bone, and the biopsy was found to be superior to the sample recovered by a conventional bone biopsy needle.

  7. Spinal anaesthesia in young patients: evaluation of needle gauge ...

    African Journals Online (AJOL)

    Background:The well-known complication of spinal anaesthesia, postdural puncture headache (PDPH), is especially troublesome in young patients. The needle gauge and configuration of needle tip appear to be the important factors in reducing the incidence of PDPH; however it may increase the incidence of technical ...

  8. Needle autopsy

    OpenAIRE

    Philip Davis Marsden

    1997-01-01

    Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsi...

  9. The location of uranium in source rocks and sites of secondary deposition at the Needle's Eye natural analogue site, Dumfries and Galloway

    International Nuclear Information System (INIS)

    Basham, I.R.; Hyslop, E.K.; Milodowski, A.E.; Pearce, J.M.

    1991-01-01

    The British Geological Survey has been conducting a coordinated research programme at the natural analogue site of Needle's Eye at Southwick on the Solway coast in south-west Scotland. This study of a naturally radioactive geochemical system has been carried out with the aim of improving our confidence in using predictive models of radionuclide migration in the geosphere. This report describes results of integrated mineralogical techniques which have been applied to the study of both the source-term and sites of secondary accumulation of uranium. Pitchblende in a polymetallic-carbonate breccia vein exposed in ancient sea-cliffs is the main source of labile uranium although other uranium-bearing minerals present in the granodiorite and hornfelsed siltstone host-rocks present probable ancillary leachable sites. In keeping with the complex chemistry of the primary sulphide-rich mineralization, a large variety of secondary U minerals has been recorded among which arsenates and hydrous silicates appear to predominate. Uranium transported in groundwaters draining the cliffs has accumulated in organic-rich estuarine/intertidal mudflat sediments of Quaternary age. Charged particle track registration techniques have demonstrated convincingly the effectiveness of humified organic matter in retarding uranium transport and, coupled with scanning electron microscopy, have indicated the important role of living plants and bacteria in uranium uptake and concentration. Computer codes used: CHEMVAL; CHEMTARD 5 figs.; 64 plates; 37 refs

  10. The location of uranium in source rocks and sites of secondary deposition at the Needle's Eye natural analogue site, Dumfries and Galloway

    International Nuclear Information System (INIS)

    Basham, I.R.; Hyslop, E.K.; Milodowski, A.E.; Pearce, J.M.

    1989-08-01

    The British Geological Survey has been conducting a co-ordinated research programme at the natural analogue site of Needle's Eye at Southwick on the Solway coast in SW Scotland. This study of a naturally radioactive geochemical system has been carried out with the aim of improving our confidence in using predictive models of radionuclide migration in the geosphere. This report describes results of integrated mineralogical techniques which have been applied to the study of both the 'source-term' and sites of secondary accumulation of uranium. Pitchblende in a polymetallic-carbonate breccia vein exposed in ancient sea-cliffs is the main source of labile uranium although other uranium-bearing minerals present in the granodiorite and hornfelsed siltstone host-rocks present probable ancillary leachable sites. In keeping with the complex chemistry of the primary sulphide-rich mineralization, a large variety of secondary U minerals has been recorded among which arsenates and hydrous silicates appear to predominate. Uranium transported in groundwaters draining the cliffs has accumulated in organic-rich estuarine/intertidal mudflat sediments of Quaternary age. Charged particle track registration techniques have demonstrated convincingly the effectiveness of humidified organic matter in retarding uranium transport and, coupled with scanning electron microscopy, have indicated an important role of living plants and bacteria in uranium uptake and concentration. (author)

  11. Initial experience using a radiofrequency powered transseptal needle.

    Science.gov (United States)

    Smelley, Matthew P; Shah, Dipak P; Weisberg, Ian; Kim, Susan S; Lin, Albert C; Beshai, John F; Burke, Martin C; Knight, Bradley P

    2010-04-01

    The purpose of this study was to determine the safety and efficacy of using a novel radiofrequency (RF) powered transseptal needle to perform transseptal puncture (TSP). TSP was performed in 35 consecutive patients undergoing left-sided catheter ablation (mean age = 51 years; male = 71%) using a RF powered transseptal needle (NRG, Adult Large and Standard Curve C1, 71 cm, Baylis Medical Company, Inc.). Prior TSP had been performed in 34% of patients. The transseptal apparatus was positioned with the tip of the dilator engaged in the fossa ovalis. RF energy was delivered to the tip of the transseptal needle using a proprietary RF generator at 10 W for 2 seconds as gentle pressure was applied to the needle. In 5 of the 41 TSPs, the needle crossed into the left atrium before RF energy was delivered. In 35 of the remaining 36 punctures, the needle was successfully advanced into the left atrium after application of RF current. In 1 patient, the TSP with the powered needle was unsuccessful but was accomplished using a standard needle. The only complication was a transient right atrial thrombus, which occurred in 2 patients. A radiofrequency powered transseptal needle can be used to perform TSP safely and successfully without the need for significant mechanical force, even in patients who have undergone TSP previously. Additional studies are needed to determine whether a powered transseptal needle should be used routinely.

  12. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  13. CPAP Tips

    Medline Plus

    Full Text Available ... a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from the U.S. Food ... 395,755 views 9:28 3 Tips for Sleeping With a CPAP - Duration: 2:02. WebMD 66, ...

  14. Needle autopsy

    Directory of Open Access Journals (Sweden)

    Philip Davis Marsden

    1997-04-01

    Full Text Available Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsia limitadamente fechada, para esclarecimento da histologia do órgão. Dessa maneira, o clínico pode resolver enigmas de doenças fatais.

  15. Effect of Blinding With a New Pragmatic Placebo Needle

    Science.gov (United States)

    Liu, Baoyan; Xu, Huanfang; Ma, Rui; Mo, Qian; Yan, Shiyan; Liu, Zhishun

    2014-01-01

    Abstract Placebo control is a useful method for determining the efficacy of a therapy. In acupuncture researches, the preferred method for placebo control is acupuncture using a placebo needle that has a blunt tip and achieves no skin penetration. We performed a crossover study to validate the blinding effect of a new type of placebo needle. Sixty volunteers were randomized to receive acupuncture using 2 types of needles with different sequences: sequence AB, involving first the pragmatic placebo needle and then the real needle, and sequence BA, in a reverse order. Placebo acupuncture was performed by administering the placebo needle through an adhesive pad without skin penetration on the acupoints LI4, RN12, BL25, and BL36. Real acupuncture was performed by needling through the pad and penetrating the skin to 15 mm using a real needle on the same acupoints. The acupuncture was administered every other day with 3 sessions for 1 type of needle. The primary outcome was the perception of needle penetration. Besides degree of acupuncture pain, type, and degree of needle sensation, needle acceptability and factors influencing the subject blinding effect were assessed. Needle penetration was felt by 100%, 90% (54/60), 88.3% (53/60), and 95% (57/60) of volunteers receiving placebo acupuncture and 98.3% (59/60), 96.7% (58/60), 95% (57/60), and 95% (57/60) of volunteers receiving real acupuncture on LI4, RN12, BL25, and BL36, respectively. Differences of the volunteers’ perception of needle penetration between the placebo needle and real needle were not significant for the 4 acupoints (all P > 0.05). Volunteers experienced fewer distension sensations (P = 0.01), a lower degree of needle sensation (P = 0.007), and less pain (P = 0.006) during placebo acupuncture than during real acupuncture. The placebo needle was more easily accepted than the real needle (OR = 1.63, 95% CI, 1.01–2.64). The influences of age, sex, educational level, acupuncture

  16. Inverse Kinematics of Concentric Tube Steerable Needles.

    Science.gov (United States)

    Sears, Patrick; Dupont, Pierre E

    2007-01-01

    Prior papers have introduced steerable needles composed of precurved concentric tubes. The curvature and extent of these needles can be controlled by the relative rotation and translation of the individual tubes. Under certain assumptions on the geometry and design of these needles, the forward kinematics problem can be solved in closed form by means of algebraic equations. The inverse kinematics problem, however, is not as straightforward owing to the nonlinear map between relative tube displacements and needle tip configuration as well as to the multiplicity of solutions as the number of tubes increases. This paper presents a general approach to solving the inverse kinematics problem using a pseudoinverse solution together with gradients of nullspace potential functions to enforce geometric and mechanical constraints.

  17. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  18. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  19. CPAP Tips

    Medline Plus

    Full Text Available ... make your opinion count. Sign in Loading... Loading... Transcript The interactive transcript could not be loaded. Loading... ... Dan Uses CPAP - Duration: 4:17. Harvard Medical School 7,950 views 4:17 Tips for building ...

  20. CPAP Tips

    Science.gov (United States)

    ... make your opinion count. Sign in Loading... Loading... Transcript The interactive transcript could not be loaded. Loading... ... Dan Uses CPAP - Duration: 4:17. Harvard Medical School 7,950 views 4:17 Tips for building ...

  1. Tipping Point

    Medline Plus

    Full Text Available ... fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash format. Almost ... accidents involving young children and furniture, appliance and tv tip-overs. The force of a large television ...

  2. Tipping Point

    Medline Plus

    Full Text Available ... impact can kill a child or cause severe injuries. About 16,000 (mostly young children) were treated in emergency rooms for tip-over related injuries in 2006, that’s about four times more injuries ...

  3. Tipping Point

    Medline Plus

    Full Text Available ... appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch ... reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The force of ...

  4. Tipping Point

    Medline Plus

    Full Text Available ... third story of a building. That kind of impact can kill a child or cause severe injuries. ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit ...

  5. A study of porcine liver motion during respiration for improving targeting in image-guided needle placements.

    Science.gov (United States)

    Srimathveeravalli, G; Leger, J; Ezell, P; Maybody, M; Gutta, N; Solomon, S B

    2013-01-01

    Liver motion due to respiration restricts targeting and needle placement accuracy during image-guided interventional procedures. Breath holds, imaging techniques, and navigation systems are used to improve targeting accuracy. Data of in-vivo liver behavior under respiration can enhance these approaches. An experimental study was performed using the swine model to capture the dynamics of liver motion during respiration using needles tipped with electromagnetic sensors. The swine liver was segmented into four lobes (right lateral, right medial, left medial and left lateral), and two sensor-tipped needles were placed in each location to acquire representative displacement data. Maximum displacement was found to occur in the left medial and left lateral lobes, in the anterior-posterior direction. Significant lobe-dependent variation in motion behavior was recorded, but a variation within a lobe was minimal and independent of needle approach. Magnitude of displacement in all lobes was found to be monotonically correlated to breathing volume. Displacement of liver was found to be out of phase with breathing by approximately 2 Hz. The positioning of the animal was also found to influence direction and magnitude of liver displacement in different lobes. We have presented previously unavailable data and insight into the role of easily controllable parameters such as breathing volume, patient positioning, and lobe-specific heterogeneity in the displacement of liver due to respiration.

  6. Geographical and climatic limits of needle types of one- and two-needled pinyon pines.

    Science.gov (United States)

    Cole, Kenneth L; Fisher, Jessica; Arundel, Samantha T; Cannella, John; Swift, Sandra

    2008-02-01

    AIM: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. LOCATION: Western North America. METHODS: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. RESULTS: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  7. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  9. Effect of vibration frequency on biopsy needle insertion force.

    Science.gov (United States)

    Tan, Lei; Qin, Xuemei; Zhang, Qinhe; Zhang, Hongcai; Dong, Hongjian; Guo, Tuodang; Liu, Guowei

    2017-05-01

    Needle insertion is critical in many clinical medicine procedures, such as biopsy, brachytherapy, and injection therapy. A platform with two degrees of freedom was set up to study the effect of vibration frequency on needle insertion force. The gel phantom deformation at the needle cutting edge and the Voigt model are utilized to develop a dynamic model to explain the relationship between the insertion force and needle-tip velocity. The accuracy of this model was verified by performing needle insertions into phantom gel. The effect of vibration on insertion force can be explained as the vibration increasing the needle-tip velocity and subsequently increasing the insertion force. In a series of needle insertion experiments with different vibration frequencies, the peak forces were selected for comparison to explore the effect of vibration frequency on needle insertion force. The experimental results indicate that the insertion force at 500Hz increases up to 17.9% compared with the force at 50Hz. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Tipping Point

    Medline Plus

    Full Text Available ... 24 hours a day. For young children whose home is a playground, it’s the best way to prevent a tip-over tragedy. Share Post Facebook Twitter ... Security, and Legal Notice | Accessibility Policy | Open Government @ CPSC | ...

  11. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ... Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign ...

  12. Kalman filter-based EM-optical sensor fusion for needle deflection estimation.

    Science.gov (United States)

    Jiang, Baichuan; Gao, Wenpeng; Kacher, Daniel; Nevo, Erez; Fetics, Barry; Lee, Thomas C; Jayender, Jagadeesan

    2018-04-01

    In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.

  13. Location, Location, Location!

    Science.gov (United States)

    Ramsdell, Kristin

    2004-01-01

    Of prime importance in real estate, location is also a key element in the appeal of romances. Popular geographic settings and historical periods sell, unpopular ones do not--not always with a logical explanation, as the author discovered when she conducted a survey on this topic last year. (Why, for example, are the French Revolution and the…

  14. Location, location, location

    NARCIS (Netherlands)

    Anderson, S.P.; Goeree, J.K.; Ramer, R.

    1997-01-01

    We analyze the canonical location-then-price duopoly game with general log- concave consumer densities. A unique pure-strategy equilibrium to the two-stage game exists if the density is not "too asymmetric" and not "too concave." These criteria are satisfied by many commonly used densities.

  15. Tip enhancement

    CERN Document Server

    Kawata, Satoshi

    2007-01-01

    This book discusses the recent advances in the area of near-field Raman scattering, mainly focusing on tip-enhanced and surface-enhanced Raman scattering. Some of the key features covered here are the optical structuring and manipulations, single molecule sensitivity, analysis of single-walled carbon nanotubes, and analytic applications in chemistry, biology and material sciences. This book also discusses the plasmonic materials for better enhancement, and optical antennas. Further, near-field microscopy based on second harmonic generation is also discussed. Chapters have been written by some of the leading scientists in this field, who present some of their recent work in this field.·Near-field Raman scattering·Tip-enhanced Raman spectroscopy·Surface-enhanced Raman spectroscopy·Nano-photonics·Nanoanalysis of Physical, chemical and biological materials beyond the diffraction limits·Single molecule detection

  16. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  17. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  18. Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures

    International Nuclear Information System (INIS)

    Haseler, Luke J.; Sibbitt, Randy R.; Sibbitt, Wilmer L.; Michael, Adrian A.; Gasparovic, Charles M.; Bankhurst, Arthur D.

    2011-01-01

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm 2 ), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of −517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (−435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.

  19. Temno biopsy needle

    International Nuclear Information System (INIS)

    Quinn, S.F.; Demlow, T.; Dunkley, B.

    1991-01-01

    This paper reports on the Temno needle which is spring-activated biopsy needle that is being marketed to radiologists as a needle that can obtain histologic cores. One hundred fifteen biopsy procedures were performed; biopsy sites included liver; retroperitoneum; lung, mediastinum, and pleura; musculoskeletal structures; thyroid; abdominal and pelvic masses; and pancreas. The needle sizes included 21-gauge, 18-gauge, 16-gauge, and 14-gauge needles. The biopsy procedures were diagnostic in 87.8D% of cases, and the average biopsy specimen measured 1.0-40.0 mm. The biopsy diagnoses included both malignant and benign processes. The Temno needle has a lightweight, nonattenuating handle that makes it especially useful for CT-guided procedures

  20. [Intrapulmonary Sewing Needle].

    Science.gov (United States)

    Hisama, Naoya; Tsunemitsu, Nobumasa; Yasumasu, Tetsuo; Yamasaki, Takashi; Uchida, Takahisa

    2016-06-01

    Intrapulmonary aberrant needles are rarely encountered in clinical practice. A 82-year-old woman, though she was asymptomatic, was referred to our department due to an abnormal shadow on a chest X-ray. Chest X-ray and chest computed tomography showed a foreign body suspected to be a sewing needle in the left upper lobe. The needle was successfully removed by video-assisted thoracoscopic surgery.

  1. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  2. Turbine blade squealer tip rail with fence members

    Science.gov (United States)

    Little, David A

    2012-11-20

    A turbine blade includes an airfoil, a blade tip section, a squealer tip rail, and a plurality of chordally spaced fence members. The blade tip section includes a blade tip floor located at an end of the airfoil distal from the root. The blade tip floor includes a pressure side and a suction side joined together at chordally spaced apart leading and trailing edges of the airfoil. The squealer tip rail extends radially outwardly from the blade tip floor adjacent to the suction side and extends from a first location adjacent to the airfoil trailing edge to a second location adjacent to the airfoil leading edge. The fence members are located between the airfoil leading and trailing edges and extend radially outwardly from the blade tip floor and axially from the squealer tip rail toward the pressure side.

  3. Intracranial sewing needles in an adult patient.

    Science.gov (United States)

    Kazanci, Atilla; Ozdemir, Halil Ibrahim; Kazanci, Burak; Kazanci, Dilek Ozturk; Er, Uygur

    2012-01-01

    A 37-year-old patient is reported with intracranial sewing needles, which were located in the right frontal lobe. Both clinical and radiological findings suggested that these needles must have been introduced in infancy before the closure of anterior fontanelle during an unsuccessful homicide. Usually intracranial foreign objects are placed due to penetrating trauma or surgical procedures. Child abuse has been known for centuries. Many types of physical traumas have been reported, especially in Western countries. In Iran, insertion of sewing needles into the brain aiming to kill the infant have been seen in a lot of cases. This situation takes part in a lot of Persian stories. We reported a 37-year-old man who had 2 intracranial sewing needles with unknown etiology.

  4. Prom Health and Safety Tips

    Science.gov (United States)

    ... Autumn Tips Camping Tips Family Reunions Gardening Tips Halloween Tips Healthy Halloween Prom Tips Spring Break Valentine Tips Winter Holiday ... Breast Cancer Assess Your Relationships Be Safe on Halloween Be Smoke-Free Check Alarm Batteries Know Your ...

  5. Pulsed photoelectric field emission from needle cathodes

    CERN Document Server

    Hernandez-Garcia, C

    2002-01-01

    Experiments have been carried out to measure the current emitted by tungsten needles with 1-mu m tip radius operated up to 50 kV. This corresponds to electric fields in the order of 10 sup 9 to 10 sup 1 sup 0 V/m. The needles were illuminated with 10-ns laser pulses at 532, 355 and 266 nm. The laser intensity was varied from 10 sup 1 sup 0 to 10 sup 1 sup 2 W/m sup 2 , limited by damage to the needle tip. The observed quantum efficiency depends on the wavelength and the electric field, approaching unity at the highest electric fields when illuminated at 266 nm. Peak currents up to 100 mA were observed in nanosecond pulses, corresponding to an estimated brightness of 10 sup 1 sup 6 A/m sup 2 sr. Since the current is controlled by the laser intensity, with only a weak voltage dependence, these cathodes can be used for infrared and ultraviolet tabletop free-electron lasers and other applications that demand short electron-beam pulses with high brightness.

  6. A portable integrated system to control an active needle

    Science.gov (United States)

    Konh, Bardia; Motalleb, Mahdi; Ashrafiuon, Hashem

    2017-04-01

    The primary objective of this work is to introduce an integrated portable system to operate a flexible active surgical needle with actuation capabilities. The smart needle uses the robust actuation capabilities of the shape memory alloy wires to drastically improve the accuracy of in medical procedures such as brachytherapy. This, however, requires an integrated system aimed to control the insertion of the needle via a linear motor and its deflection by the SMA wire in real-time. The integrated system includes a flexible needle prototype, a Raspberry Pi computer, a linear stage motor, an SMA wire actuator, a power supply, electromagnetic tracking system, and various communication supplies. The linear stage motor guides the needle into tissue. The power supply provides appropriate current to the SMA actuator. The tracking system measures tip movement for feedback, The Raspberry Pi is the central tool that receives the tip movement feedback and controls the linear stage motor and the SMA actuator via the power supply. The implemented algorithms required for communication and feedback control are also described. This paper demonstrates that the portable integrated system may be a viable solution for more effective procedures requiring surgical needles.

  7. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1

  8. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  9. CPAP Tips

    Medline Plus

    Full Text Available ... in to report inappropriate content. Sign in Transcript Statistics Add translations 203,819 views Like this video? ... Language: English Location: United States Restricted Mode: Off History Help Loading... Loading... Loading... About Press Copyright Creators ...

  10. CPAP Tips

    Medline Plus

    Full Text Available ... to make your opinion count. Sign in Don't like this video? Sign in to make your ... Language: English Location: United States Restricted Mode: Off History Help Loading... Loading... Loading... About Press Copyright Creators ...

  11. CPAP Tips

    Medline Plus

    Full Text Available ... in to report inappropriate content. Sign in Transcript Statistics Add translations 205,368 views Like this video? ... Language: English Location: United States Restricted Mode: Off History Help Loading... Loading... Loading... About Press Copyright Creators ...

  12. Tips for Daily Living

    Science.gov (United States)

    ... Tips and Gadgets for Daily Activities Dressing Tips Shopping Tips Modifying the Bathroom Driving After Stroke Medication ... and resources. Find a group in your area . Online Support If there is not a support group ...

  13. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  14. Video endoscopy: removal of retained sewing needles from the duodenum.

    Science.gov (United States)

    Gajbhiye, Ashok S; Gajbhiye, Raj N; Tirupude, Bhupesh H; Bajaj, Prasang P; Gupta, Tarush H

    2013-06-01

    We report an interesting case of a 21-year-old unmarried girl who swallowed six sewing needles. Her complaints were pain in the epigastrium, associated with nausea and vomiting. On examination, there was mild tenderness in the epigastrium. X-ray of the abdomen and endoscopy confirmed the presence of six needles in the duodenum, with tips lodged in the duodenal wall. Psychiatric opinion was sought which was normal. Under video endoscope (Pentax 2.8, EG 27708) guidance with Captura biopsy forceps without spikes (Cook DBF-2.4-160-S), six sewing needles were removed successfully from the duodenum through the endoscope channel without any complications. However, a video endoscopic removal of the retained six needles from duodenum is probably being reported for the first time.

  15. Selection of case studies describing PICC tip malposition.

    Science.gov (United States)

    Jackson, Andrew; Buttle, Andrew

    2016-07-28

    This article presents a number of case studies, spanning a 12-month period, associated with peripherally inserted central catheter (PICC) tip location. The aim is to generate debate around the journey PICC tips may take; it is not the purpose of this article to debate technological solutions to the issue of PICC tip location. The discussion of each case illustrates a wide range of potential aberrant PICC tip locations and offers an insight into how the abberant tip location was resolved in each case.

  16. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes.

    Science.gov (United States)

    Præstmark, Kezia A; Jensen, Morten L; Madsen, Nils B; Kildegaard, Jonas; Stallknecht, Bente M

    2016-01-01

    Pen needles used for subcutaneous injections have gradually become shorter, thinner and more thin walled, and thereby less robust to patient reuse. Thus, different needle sizes, alternative tip designs and needles resembling reuse were tested to explore how needle design influences ease of insertion, pain and skin trauma. 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m 2 were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. Needle diameter was positively related to PF and SBP (ptrend relation. Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome was dependent of SBP increase. The shape and design of a needle and the needle tip affect ease of insertion, pain and skin trauma. Relations are seen across different data acquisition methods and across species, enabling needle performance testing outside of clinical trials. NCT02531776; results.

  17. CPAP Tips

    Medline Plus

    Full Text Available ... Why it's Bad. How to Fix Mouth Leaking. Anatomy of the Mouth Leak. - Duration: 9:40. TheLankyLefty27 ... Language: English Location: United States Restricted Mode: Off History Help Loading... Loading... Loading... About Press Copyright Creators ...

  18. Experiments with needle bearings

    Science.gov (United States)

    Ferretti, Pericle

    1933-01-01

    Experiments and results are presented in testing needle bearings, especially in comparison with roller bearings. Reduction in coefficient of friction is discussed as well as experimental methods and recording devices.

  19. Full tip imaging in atom probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Du, Sichao [School of Physics, The University of Sydney, NSW 2006 (Australia); Burgess, Timothy [Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 0200 (Australia); Tjing Loi, Shyeh [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); Gault, Baptiste [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006 (Australia); Department of Materials Science and Engineering, McMaster University, 1280 Main St W, Hamilton, ON, Canada L8S 4L8 (Canada); Gao, Qiang [Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 0200 (Australia); Bao, Peite; Li, Li [School of Physics, The University of Sydney, NSW 2006 (Australia); Cui, Xiangyuan; Kong Yeoh, Wai [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); Hoe Tan, Hark; Jagadish, Chennupati [Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 0200 (Australia); Ringer, Simon P. [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006 (Australia); Zheng, Rongkun, E-mail: rongkun.zheng@sydney.edu.au [School of Physics, The University of Sydney, NSW 2006 (Australia)

    2013-01-15

    Atom probe tomography (APT) is capable of simultaneously revealing the chemical identities and three dimensional positions of individual atoms within a needle-shaped specimen, but suffers from a limited field-of-view (FOV), i.e., only the core of the specimen is effectively detected. Therefore, the capacity to analyze the full tip is crucial and much desired in cases that the shell of the specimen is also the region of interest. In this paper, we demonstrate that, in the analysis of III-V nanowires epitaxially grown from a substrate, the presence of the flat substrate positioned only micrometers away from the analyzed tip apex alters the field distribution and ion trajectories, which provides extra image compression that allows for the analysis of the entire specimen. An array of experimental results, including field desorption maps, elemental distributions, and crystallographic features clearly demonstrate the fact that the whole tip has been imaged, which is confirmed by electrostatic simulations. -- Highlights: Black-Right-Pointing-Pointer The full tip has been imaged by atom probe tomography. Black-Right-Pointing-Pointer The conductive substrate close to specimen tip introduces extra image compression. Black-Right-Pointing-Pointer The apex of the tip is far from a hemispherical shape. Black-Right-Pointing-Pointer This work demonstrates a way to increase the FOV of APT.

  20. Systemic air embolism during percutaneous core needle biopsy of the lung: frequency and risk factors

    Directory of Open Access Journals (Sweden)

    Freund Martin C

    2012-02-01

    Full Text Available Abstract Background Detection of risk factors for an air embolism in the left atrium, left ventricle, or systemic circulation (systemic air embolism, SAE during a percutaneous core needle biopsy (PCNB of the thorax. Methods In a retrospective observational study, all PCNBs of the thorax in 610 patients between 2007 and 2009 were analyzed. The SmartStep™ technique (General Electric was used for the biopsy, with which the examiner can prepare a batch of three 1.25-mm or 2.5-mm collimated slices within a second using a foot switch in the CT room to check the needle position. The image data thus generated and the control CT scans that followed were examined retrospectively for the presence of intravascular air. Intravascular air was defined as two or more adjacent voxels with absorption values of Results The radiological incidence of an SAE during a PCNB was 3.8% (23/610 patients, whereas the clinically apparent incidence was 0.49%. Two patients developed clinical symptoms consisting of transient hemiplegia or transient amaurosis; one died due to a fatal SAE of the coronary arteries. The mortality was thus 0.16%. The depth of the needle in the lesion (Wald: 6.859, endotracheal anesthesia (Wald: 5.721, location of the lesion above the level of the left atrium (Wald: 5.159, and prone position of the patients (Wald: 4.317 were independent risk factors for the incidence of an SAE (p Conclusion If possible, the PCNB should be performed under local anesthesia. We recommend avoiding endotracheal anesthesia and prone position. Whenever possible, patients should be positioned on the back in such a way that the tumor is lower than the left atrium. The tip of the needle should be within the tumor during the biopsy procedure.

  1. Genetics studies involving Swiss needle cast.

    Science.gov (United States)

    R. Johnson; F. Temel; K. Jayawickrama

    2002-01-01

    Three studies were analyzed this year that examined genetic aspects of Swiss needle cast (SNC) tolerance . Families sampled across the Siuslaw National forest showed differences in foliage health traits, but very little of the variation could be explained by environmental or climatic conditions at the parent tree location. Five test sites of the Nehalem series of...

  2. Terpenoid resin distribution in conifer needles with implications for red tree vole, Arborimus longicaudus, foraging

    Science.gov (United States)

    Rick G. Kelsey; Eric D. Forsman; James K. Swingle

    2009-01-01

    Tree voles are dietary specialists, feeding almost exclusively on conifer needles and bark. They reduce their exposure to conifer chemical defenses by physically removing resin ducts from many needles before ingesting the remaining tissue. The portion of needle removed differs among tree species, depending on the location of the resin ducts. To evaluate the amount of...

  3. CT-guided needle puncture for diagnosis and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Takashi; Kaji, Tatsumi; Ashida, Hiroshi; Nakajima, Yasuo; Nosaka, Shunsuke; Kuroki, Kazunori; Kurihara, Yasuyuki; Hara, Akihiko; Ishikawa, Tohru

    1987-12-01

    CT-guided needle puncture was performed in 16 aspiration biopsies, 12 nerve neurolysis, 6 percutaneous treatment such as abscess drainage. CT-guidance was better than fluoroscopic or sonographic control, in dealing with small, deeply-located lesions where precise location of needle is inevitable. We used the slotted 20 gauge thin-walled needle for biopsy, 21 or 22-gauge chiba-needle for other purposes. Over-all accuracy was 93.3 % in aspiration biopsies and technical successful rate in nerve neurolysis was 100 %. Only one pneumothorax was noted as a complication. CT-guided needle puncture was safe and exact, especially when fluoroscopic or sonographic guidance was not possible.

  4. Tips to overcome technical challenges in EUS-guided tissue acquisition

    DEFF Research Database (Denmark)

    Vilmann, Peter; Seicean, Andrada; Săftoiu, Adrian

    2014-01-01

    . The endosonographic technique can be improved when several tips and tricks useful to overcome challenges of FNA are known. Technical challenges of FNA are related to the characteristics of the lesion and its surroundings, sonographic imaging, and limitations related to the needle. Several tips and tricks necessary...

  5. Hot tips on hot tips: technical problems with percutaneous insertion of a microwave antenna through rigid tissue

    International Nuclear Information System (INIS)

    Danaher, Luke A.; Steinke, Karin

    2013-01-01

    We report an instance of microwave antenna breakage upon insertion through rigid costal cartilage and tip dislodgement during withdrawal of the antenna. Furthermore, we highlight antenna incompatibility with certain coaxial needles. Given the complexity and fragility of microwave antennas, it is not recommended to insert them through rigid tissue such as cartilage or calcified pleural plaques.

  6. Molecular model of a type III secretion system needle: Implications for host-cell sensing.

    Science.gov (United States)

    Deane, Janet E; Roversi, Pietro; Cordes, Frank S; Johnson, Steven; Kenjale, Roma; Daniell, Sarah; Booy, Frank; Picking, William D; Picking, Wendy L; Blocker, Ariel J; Lea, Susan M

    2006-08-15

    Type III secretion systems are essential virulence determinants for many Gram-negative bacterial pathogens. The type III secretion system consists of cytoplasmic, transmembrane, and extracellular domains. The extracellular domain is a hollow needle protruding above the bacterial surface and is held within a basal body that traverses both bacterial membranes. Effector proteins are translocated, via this external needle, directly into host cells, where they subvert normal cell functions to aid infection. Physical contact with host cells initiates secretion and leads to formation of a pore, thought to be contiguous with the needle channel, in the host-cell membrane. Here, we report the crystal structure of the Shigella flexneri needle subunit MxiH and a complete model for the needle assembly built into our three-dimensional EM reconstruction. The model, combined with mutagenesis data, reveals that signaling of host-cell contact is relayed through the needle via intersubunit contacts and suggests a mode of binding for a tip complex.

  7. Fluoroscopically guided transforaminal epidural dry needling for lumbar spinal stenosis using a specially designed needle

    Directory of Open Access Journals (Sweden)

    Ahn Kang

    2010-08-01

    Full Text Available Abstract Background This report describes the methodological approach and clinical application of a minimally invasive intervention to treat lumbar spinal stenosis (LSS. Methods Thirty-four patients with LSS underwent fluoroscopically guided transforaminal epidural dry needling using a specially designed flexed Round Needle. The needle was inserted 8-12 cm lateral to the midline at the level of the stenosis and advanced to a position between the anterior side of the facet joint and pedicle up to the outer-third of the pedicle. The needle was advanced medially and backed laterally within a few millimetres along the canal side of the inferior articular process between the facet joint and pedicle. The procedure was completed when a marked reduction in resistance was felt at the tip of the needle. The procedure was performed bilaterally at the level of the stenosis. Results The average follow-up period was 12.9 ± 1.1 months. The visual analogue scale (VAS pain score was reduced from 7.3 ± 2.0 to 4.6 ± 2.5 points, the Oswestry Disability Index (ODI score decreased from 41.4 ± 17.2 to 25.5 ± 12.6% and the average self-rated improvement was 52.6 ± 33.1%. The VAS scores indicated that 14 (41.2% patients reported a "good" to "excellent" treatment response, while 11 (32.4% had a "good" to "excellent" treatment response on the ODI and 22 (64.7% had a "good" to "excellent" treatment response on the self-rated improvement scale. Conclusions These results suggest that fluoroscopically guided transforaminal epidural dry needling is effective for managing LSS.

  8. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery

    Science.gov (United States)

    Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.

    2017-03-01

    Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.

  10. A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver.

    Science.gov (United States)

    Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay

    2018-01-01

    The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.

  11. Trigger Point Dry Needling.

    Science.gov (United States)

    2017-03-01

    Increasingly, physical therapists in the United States and throughout the world are using dry needling to treat musculoskeletal pain, even though this treatment has been a controversial addition to practice. To better generalize to physical therapy practice the findings about dry needling thus far, the authors of a study published in the March 2017 issue of JOSPT identified the need for a systematic review examining the effectiveness of dry needling performed by physical therapists on people with musculoskeletal pain. Their review offers a meta-analysis of data from several included studies and assesses the evidence for risks of bias. J Orthop Sports Phys Ther 2017;47(3):150. doi:10.2519/jospt.2017.0502.

  12. [Bone biopsy needles: mechanical properties, needle design and specimen quality].

    Science.gov (United States)

    Keulers, A; Cunha-Cruz, V C; Bruners, P; Penzkofer, T; Braunschweig, T; Schmitz-Rode, T; Mahnken, A

    2011-03-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Healthy Vision Tips

    Science.gov (United States)

    ... for Kids >> Healthy Vision Tips Listen All About Vision About the Eye Ask a Scientist Video Series ... Links to More Information Optical Illusions Printables Healthy Vision Tips Healthy vision starts with you! Use these ...

  14. Sci—Fri PM: Topics — 08: The Role and Benefits of Electromagnetic Needle-Tracking Technologies in Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Beaulieu, L.; Racine, E.; Boutaleb, S.; Filion, O. [Département de Radio-Oncologie et Centre de Recherche du CHU de Québec, CHU de Québec, Québec (Québec), and Département de Physique, de Génie Physique et d' Optique et Centre de recherche en sur le Cancer, Université Laval, Québec (Québec) (Canada); Poulin, E.; Hautvast, G. [Biomedical Systems, Philips Group Innovation, High Tech Campus 34 (HTC 34), Eindhoven (Netherlands); Binnekamp, D. [Integrated Clinical Solutions and Marketing, Philips Healthcare, Veenpluis 4-6, Best (Netherlands)

    2014-08-15

    In modern brachytherapy, application of large doses of ionizing radiation in a limited number of fractions is frequent. Furthermore, as with any surgical procedures, brachytherapy is subject to learning curve effects. In this context, there could be advantages of integrating real-time tracking of needles/catheters to existing protocols given the recent prominent advances in tracking technologies. In this work, we review the use of an electromagnetic tracking system (EMTS) based on the second generation Aurora® Planar Field Generator (Northern Digital Inc) and custom design needles (Philips Healthcare) for brachytherapy applications. The position and orientation information is obtained from 5 degrees of freedom sensors. Basic system performance characterization is performed in well-controlled conditions to establish accuracy and reproducibility as well as potential interference from standard brachytherapy equipment. The results show that sensor locations can be tracked to within 0.04mm (la) when located within 26cm of the generator. Orientation accuracy of the needle remained within ±1° in the same region, but rose quickly at larger distances. The errors on position and orientation strongly dependent the sensor position in the characterization volume (500×500×500mm{sup 3}). The presence of an ultrasound probe was shown to have negligible effects on tracking accuracy. The use of EMTS for automatic catheter/applicator reconstruction was also explored. Reconstruction time was less than 10 sec/channel and tips identification was within 0.69±0.29mm of the reference values. Finally, we demonstrate that hollow needle designs with special EM adaptation also allow for real-time seed drop position estimation. In phantom experiments showed that drop positions were on average within 1.6±0.9mm of the reference position measured from μCT. Altogether, EMTS offer promising benefits in a wide range of brachytherapy applications.

  15. Digestive Health Tips

    Science.gov (United States)

    ... Home / Digestive Health Topic / Digestive Health Tips Digestive Health Tips Basics 10 Tips on Belching, Bloating, and Flatulence Belching is caused by swallowed air from: Eating or drinking too fast Poorly fitting dentures; not chewing food completely Carbonated beverages Chewing gum or sucking on ...

  16. Mosquito inspired medical needles

    DEFF Research Database (Denmark)

    Lenau, Torben Anker; Hesselberg, Thomas; Drakidis, Alexandros Dimitrios

    2017-01-01

    The stinging proboscis in mosquitos have diameters of only 40-100 μm which is much less than the thinnest medical needles and the mechanics of these natural stinging mechanisms have therefore attracted attention amongst developers of injection devises. The mosquito use a range of different...

  17. Tip studies using CFD and comparison with tip loss models

    DEFF Research Database (Denmark)

    Hansen, Martin Otto Laver; Johansen, J.

    2004-01-01

    The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD......The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD...

  18. Predicting casualties implied by TIPs

    Science.gov (United States)

    Trendafiloski, G.; Wyss, M.; Wyss, B. M.

    2009-12-01

    When an earthquake is predicted, forecast, or expected with a higher than normal probability, losses are implied. We estimated the casualties (fatalities plus injured) that should be expected if earthquakes in TIPs (locations of Temporarily Increased Probability of earthquakes) defined by Kossobokov et al. (2009) should occur. We classified the predictions of losses into the categories red (more than 400 fatalities or more than 1,000 injured), yellow (between 100 and 400 fatalities), green (fewer than 100 fatalities), and gray (undetermined). TIPs in Central Chile, the Philippines, Papua, and Taiwan are in the red class, TIPs in Southern Sumatra, Nicaragua, Vanatu, and Honshu in the yellow class, and TIPs in Tonga, Loyalty Islands, Vanatu, S. Sandwich Islands, Banda Sea, and the Kuriles, are classified as green. TIPs where the losses depend moderately on the assumed point of major energy release were classified as yellow; TIPs such as in the Talaud Islands and in Tonga, where the losses depend very strongly on the location of the epicenter, were classified as gray. The accuracy of loss estimates after earthquakes with known hypocenter and magnitude are affected by uncertainties in transmission and soil properties, the composition of the building stock, the population present, and the method by which the numbers of casualties are calculated. In the case of TIPs, uncertainties in magnitude and location are added, thus we calculate losses for a range of these two parameters. Therefore, our calculations can only be considered order of magnitude estimates. Nevertheless, our predictions can come to within a factor of two of the observed numbers, as in the case of the M7.6 earthquake of October 2005 in Pakistan that resulted in 85,000 fatalities (Wyss, 2005). In subduction zones, the geometrical relationship between the earthquake source capable of a great earthquake and the population is clear because there is only one major fault plane available, thus the epicentral

  19. A data-driven soft sensor for needle deflection in heterogeneous tissue using just-in-time modelling.

    Science.gov (United States)

    Rossa, Carlos; Lehmann, Thomas; Sloboda, Ronald; Usmani, Nawaid; Tavakoli, Mahdi

    2017-08-01

    Global modelling has traditionally been the approach taken to estimate needle deflection in soft tissue. In this paper, we propose a new method based on local data-driven modelling of needle deflection. External measurement of needle-tissue interactions is collected from several insertions in ex vivo tissue to form a cloud of data. Inputs to the system are the needle insertion depth, axial rotations, and the forces and torques measured at the needle base by a force sensor. When a new insertion is performed, the just-in-time learning method estimates the model outputs given the current inputs to the needle-tissue system and the historical database. The query is compared to every observation in the database and is given weights according to some similarity criteria. Only a subset of historical data that is most relevant to the query is selected and a local linear model is fit to the selected points to estimate the query output. The model outputs the 3D deflection of the needle tip and the needle insertion force. The proposed approach is validated in ex vivo multilayered biological tissue in different needle insertion scenarios. Experimental results in five different case studies indicate an accuracy in predicting needle deflection of 0.81 and 1.24 mm in the horizontal and vertical lanes, respectively, and an accuracy of 0.5 N in predicting the needle insertion force over 216 needle insertions.

  20. The TIPS Liquidity Premium

    DEFF Research Database (Denmark)

    Andreasen, Martin Møller; Christensen, Jens H.E.; Simon Riddell, Simon

    We introduce an arbitrage-free term structure model of nominal and real yields that accounts for liquidity risk in Treasury inflation-protected securities (TIPS). The novel feature of our model is to identify liquidity risk from individual TIPS prices by accounting for the tendency that TIPS, like...... most fixed-income securities, go into buy-and-hold investors' portfolios as time passes. We find a sizable and countercyclical TIPS liquidity premium, which greatly helps our model in matching TIPS prices. Accounting for liquidity risk also improves the model's ability to forecast inflation and match...

  1. Infraorbital Foramen and Pterygopalatine Fossa Location in Dry Skulls: Anatomical Guidelines for Local Anesthesia

    Directory of Open Access Journals (Sweden)

    Omar Masabni

    2017-01-01

    Full Text Available Purpose. The aim of the study was to locate the infraorbital foramen (IOF in relation to the infraorbital margin (IOM for proper injections of local anesthetics in skull specimens. Another aim was to determine the depth of needle penetration into pterygopalatine fossa through the greater palatine canal (GPC. Materials and Methods. 102 skull halves were used to measure the distances between (1 IOF and IOM and (2 IOF and alveolar ridge of maxilla at second premolar. Needles were inserted and bent at a 45° angle, passing through the GPC at the level of hard palate. The depth of the tip of needle emerging out of GPC into pterygopalatine fossa was measured. Results. The mean distance between IOF and IOM was 6.46±1.57 mm on the right side and 6.74±1.72 mm on the left. The mean distance between IOF and alveolar bone process of the maxilla at second premolar was 29.07±3.58 mm on the right side and 29.39±3.78 mm on the left. The mean depth of penetration of the needle into the pterygopalatine fossa was similar on both sides. Conclusions. Proper identification of IOF and pterygopalatine fossa is of great significance during local anesthesia injections, due to their close proximity to vital anatomic structures.

  2. Arctic climate tipping points.

    Science.gov (United States)

    Lenton, Timothy M

    2012-02-01

    There is widespread concern that anthropogenic global warming will trigger Arctic climate tipping points. The Arctic has a long history of natural, abrupt climate changes, which together with current observations and model projections, can help us to identify which parts of the Arctic climate system might pass future tipping points. Here the climate tipping points are defined, noting that not all of them involve bifurcations leading to irreversible change. Past abrupt climate changes in the Arctic are briefly reviewed. Then, the current behaviour of a range of Arctic systems is summarised. Looking ahead, a range of potential tipping phenomena are described. This leads to a revised and expanded list of potential Arctic climate tipping elements, whose likelihood is assessed, in terms of how much warming will be required to tip them. Finally, the available responses are considered, especially the prospects for avoiding Arctic climate tipping points.

  3. Toward Transoral Peripheral Lung Access: Combining Continuum Robots and Steerable Needles.

    Science.gov (United States)

    Swaney, Philip J; Mahoney, Arthur W; Hartley, Bryan I; Remirez, Andria A; Lamers, Erik; Feins, Richard H; Alterovitz, Ron; Webster, Robert J

    2017-03-01

    Lung cancer is the most deadly form of cancer in part because of the challenges associated with accessing nodules for diagnosis and therapy. Transoral access is preferred to percutaneous access since it has a lower risk of lung collapse, yet many sites are currently unreachable transorally due to limitations with current bronchoscopic instruments. Toward this end, we present a new robotic system for image-guided trans-bronchoscopic lung access. The system uses a bronchoscope to navigate in the airway and bronchial tubes to a site near the desired target, a concentric tube robot to move through the bronchial wall and aim at the target, and a bevel-tip steerable needle with magnetic tracking to maneuver through lung tissue to the target under closed-loop control. In this work, we illustrate the workflow of our system and show accurate targeting in phantom experiments. Ex vivo porcine lung experiments show that our steerable needle can be tuned to achieve appreciable curvature in lung tissue. Lastly, we present targeting results with our system using two scenarios based on patient cases. In these experiments, phantoms were created from patient-specific computed tomography information and our system was used to target the locations of suspicious nodules, illustrating the ability of our system to reach sites that are traditionally inaccessible transorally.

  4. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    Science.gov (United States)

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  5. Numerical investigation of the formation of Trichel pulses in a needle-plane geometry

    International Nuclear Information System (INIS)

    Dordizadeh, Peyman; Adamiak, Kazimierz; Peter Castle, G S

    2015-01-01

    This paper presents a numerical investigation of the formation of the Trichel pulses in negative dc corona discharge for a needle-plane configuration in atmospheric air. A 2D axisymmetric model of the problem considering three charged species and consisting of a hyperboloid needle with a tip radius of 35 μm and needle-plane spacing of 6 mm over the voltage range of  −3.5 kV to  −12 kV has been studied. A commercial finite element package COMSOL was used for simultaneously solving three convection-diffusion equations along with Poisson’s equation. In order to obtain a better understanding of the processes which lead to the pulse formation, a close look is taken at one of the pulses. The distributions of the major charged species and the timeline of peak-values of charged species densities and electric field are presented. Through tracing the evolution of the locations of the peak densities of the charged species some new insights have been provided. The configuration of the model was chosen so that the simulation results could be compared with the experimental data published by Lama and Gallo. The numerical results were in acceptable agreement with the experimental values. Some explanations are given for the discrepancies between experimental and simulation results. It is also shown, that as the frequency of the pulses increases with voltage, the transition from Trichel pulse discharge to glow discharge initiates and full glow discharge is reached at  −12 kV. (paper)

  6. Structure of Phage P22 Cell Envelope-Penetrating Needle

    Energy Technology Data Exchange (ETDEWEB)

    Olia, A.S.; Casjens, S.; Cingolani, G.

    2009-06-02

    Bacteriophage P22 infects Salmonella enterica by injecting its genetic material through the cell envelope. During infection, a specialized tail needle, gp26, is injected into the host, likely piercing a hole in the host cell envelope. The 2.1-{angstrom} crystal structure of gp26 reveals a 240-{angstrom} elongated protein fiber formed by two trimeric coiled-coil domains interrupted by a triple {beta}-helix. The N terminus of gp26 plugs the portal protein channel, retaining the genetic material inside the virion. The C-terminal tip of the fiber exposes {beta}-hairpins with hydrophobic tips similar to those seen in class II fusion peptides. The {alpha}-helical core connecting these two functionally polarized tips presents four trimerization octads with consensus sequence IXXLXXXV. The slender conformation of the gp26 fiber minimizes the surface exposed to solvent, which is consistent with the idea that gp26 traverses the cell envelope lipid bilayers.

  7. The Shigella T3SS needle transmits a signal for MxiC release, which controls secretion of effectors.

    Science.gov (United States)

    Martinez-Argudo, Isabel; Blocker, Ariel J

    2010-12-01

    Type III secretion systems (T3SSs) are key determinants of virulence in many Gram-negative bacteria, including animal and plant pathogens. They inject 'effector' proteins through a 'needle' protruding from the bacterial surface directly into eukaryotic cells after assembly of a 'translocator' pore in the host plasma membrane. Secretion is a tightly regulated process, which is blocked until physical contact with a host cell takes place. Host cell sensing occurs through a distal needle 'tip complex' and translocators are secreted before effectors. MxiC, a Shigella T3SS substrate, prevents premature effector secretion. Here, we examine how the different parts of T3SSs work together to allow orderly secretion. We show that T3SS assembly and needle tip composition are not altered in an mxiC mutant. We find that MxiC not only represses effector secretion but that it is also required for translocator release. We provide genetic evidence that MxiC acts downstream of the tip complex and then the needle during secretion activation. Finally, we show that the needle controls MxiC release. Therefore, for the first time, our data allow us to propose a model of secretion activation that goes from the tip complex to cytoplasmic MxiC via the needle. © 2010 Blackwell Publishing Ltd.

  8. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  9. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  10. Tips in Reading Instruction.

    Science.gov (United States)

    Ediger, Marlow

    Some tips can assist teachers in guiding each pupil to achieve more optimally, with respect to the ability to read well and reading comprehension. Among these 10 specific tips are: (1) teach individualized phonics in context; (2) assist the student to read in proper thought units by covering up words in sentences for clarification; (3) assist…

  11. ADHD: Tips to Try

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español ADHD: Tips to Try KidsHealth / For Teens / ADHD: Tips to Try Print en español TDAH: Consejos que puedes probar ADHD , short for attention deficit hyperactivity disorder , is a ...

  12. Total Telephone Tips.

    Science.gov (United States)

    Corder, Lloyd E.; And Others

    This manual of telephone behavior tips for business and sales professionals offers ways to handle the disgruntled caller and makes suggestions on topics relevant to the telephone. The manual is divided into the following sections and subsections: (1) Common Courtesy (staff tips, answering the telephone, screening calls, transferring calls, taking…

  13. Needling the early universe

    International Nuclear Information System (INIS)

    Hawkins, I.; Wright, E.L.

    1988-01-01

    The possibility that the whole microwave background can be produced by a bright population of pregalactic stars at a redshift of a few hundred is explored. The radiation is thermalized by a combination of amorphous silicate, amorphous carbon, graphite, and needle-shaped conducting grains which give rise to the opacity needed at wavelengths greater than 3 cm. The occurrence of distortion in a primordial microwave background spectrum due to its interaction with Population III stars and dust is investigated. The possibility of producing deviations small enough to be consistent with the best available observations, but still detectable by COBE, is considered. 65 references

  14. Enhanced visual acuity with echogenic needles in ultrasound-guided axillary brachial plexus block: a randomized, comparative, observer-blinded study.

    Science.gov (United States)

    Abbal, B; Choquet, O; Gourari, A; Bouic, N; Massone, A; Biboulet, P; Bringuier, S; Capdevila, X

    2015-04-01

    We prospectively evaluated the effect of insertion angle on the visibility of echogenic and nonechogenic needles in phantoms and in axillary nerve blocks in patients. Conventional and echogenic needles were studied in phantoms at insertion angles of 0-30°, 30-45°, and ≥ 45°. Operators rated comfort and image quality during the procedure and experts blinded to the needle groups randomly analyzed videos for tip and shaft visibility, surrounding tissue visibility, sharpness of the needle surface, and percentage of time with the needle completely visible. Patients scheduled for axillary nerve block were prospectively enrolled in the clinical study. Needle insertion angles were 0-30° for the median nerve approach, 30-45° for the radial nerve, and ≥ 45° for the musculocutaneous nerve. The same needle parameters were analyzed during the procedure and on videos. Physician comfort and image quality were significantly better for echogenic needles for phantoms and patients at 30-45° and ≥ 45° insertion angles. Needle tip and shaft visibility at 30-45° and ≥ 45° insertion angles in phantoms and for the musculocutaneous nerve in patients were significantly improved, as well as the percentage with complete needle visualization during the procedure. Tissue visibility and needle sharpness were significantly superior for conventional needles. There were no differences concerning block parameters and adverse events. Needles with enhanced echogenicity improved physician comfort, image quality, needle visibility, and visualization time of the needle during ultrasound-guided procedures in phantoms and axillary nerve blocks using insertion angles of 30-45° and ≥ 45°.

  15. Root canal debris removal using different irrigating needles: An SEM study

    Directory of Open Access Journals (Sweden)

    Sheetal Ghivari

    2011-01-01

    Full Text Available Aim: This study was carried out to compare the efficacy of three irrigating needle designs in removal of debris from different parts of the root canal. Materials and Methods: Thirty human maxillary canines were prepared using HERO Shaper rotary system and irrigated with 1 ml of 5.25% sodium hypochlorite (NaOCl after each instrument change. Three 25-gauge irrigation needle designs - brush-covered Navi Tip FX (Group I, side-vented needle RC Twents (Group II and single-beveled (Group III irrigating needles - were tested for their efficiency in debris removal in three different parts of the root canal (n=10 canals per group. Following instrumentation, the roots were vertically sectioned and divided into coronal, middle and apical thirds for observation under scanning electron microscope (×200 magnification. Debris on the canal wall was evaluated by using a four-scale scoring system described by Paque and his co-workers. Results: The canals irrigated with brush-covered needle Navi Tip FX (Group I showed lower average debris score, indicating greater removal of debris in coronal third as compared to middle and apical thirds, whereas the canals irrigated with side-vented needle (Group II and single-beveled needle (Group III exhibited lower average score in the middle third than coronal and apical thirds. All the three needle designs exhibited higher debris score in apical third of the root canal. Tukey multiple comparisons test was applied at a significance level of P>0.05. A statistically significant difference (P<0.05 was observed in the debris removal in the coronal and middle thirds of root canals irrigated with brush-covered Navi Tip FX (Group I and side-vented (Group II needles, respectively, when compared with other needle design groups. Conclusion: Within the limitations of this study, it can be concluded that all the needle designs tested were effective in certain regions of the root canal with apical third uncleaned. Side-vented needle by

  16. Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces

    NARCIS (Netherlands)

    Abayazid, Momen; Moreira, Pedro; Shahriari, Navid; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    In this paper, we present a system capable of automatically steering a bevel-tipped flexible needle under ultrasound guidance toward a physical target while avoiding a physical obstacle embedded in gelatin phantoms and biological tissue with curved surfaces. An ultrasound pre-operative scan is

  17. Patients’ Knowledge of and Practices Relating to the Disposal of Used Insulin Needles

    Directory of Open Access Journals (Sweden)

    Kerri T. Musselman, PharmD

    2010-01-01

    Full Text Available Objective: To determine (1 how patients currently dispose of used insulin needles, (2 whether patients were educated about disposal of their used insulin needles, and (3 who educated patients about the disposal of their used insulin needles.Methods: A self-administered questionnaire was designed for this study. The survey assessed patient knowledge about disposal of used insulin needles and the patient-reported source and location of education about disposal techniques. The questionnaire was administered to a convenience sample of patients from four locations in Richmond, Virginia. Any patient who used insulin, was at least 18 years old, and was willing to complete the survey was eligible for inclusion.Results: Fifty responses were received with 40% indicating that education had been received on the disposal of used needles. From that 40%, nurses were identified as the source of education 60% of the time and pharmacists 25% of the time. Approximately 50% of the respondents reported disposing of used needles directly in the trash when at home. While away from home, 22% reported placing used needles in the trash, and 38% took them home for disposal.Conclusion: Patients are not consistently educated regarding the proper disposal of used needles. Health care practitioners should play a larger role in educating patients about the potential risks of inappropriate needle disposal and appropriate disposal methods. Future research is still needed to understand fully the magnitude of the problems associated with inappropriate needle disposal by patients.

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver). Portal hypertension can also occur in children, although children are much less likely to require a TIPS. ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... vs. risks? What are the limitations of TIPS? What is a Transjugular Intrahepatic Portosystemic Shunt (TIPS)? A ... likely to require a TIPS. top of page What are some common uses of the procedure? A ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... TIPS is a minimally invasive procedure that typically has a shorter recovery time than surgery. Your TIPS ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... needle (a special long needle extending from the neck into the liver). A stent is then placed ... the procedure include: fever muscle stiffness in the neck bruising on the neck at the point of ...

  2. First Aid Tips

    Science.gov (United States)

    ... Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI for Kids » First Aid Tips Listen All About Vision About the Eye ...

  3. Tips for Daily Life

    Science.gov (United States)

    ... chapter Join our online community Tips for Daily Life Coping skills will help you handle day-to- ... challenges, maximize your independence and live a meaningful life with your diagnosis. Accepting changes Creating a coping ...

  4. Toilet training tips

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000944.htm Toilet training tips To use the sharing features on ... and 'pee'. Teaching Your Child to Use the Toilet Once your child is comfortable sitting on the ...

  5. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  6. The Problem of Metal Needles in Acupuncture-fMRI Studies

    Directory of Open Access Journals (Sweden)

    Florian Beissner

    2011-01-01

    Full Text Available Acupuncture is a therapy based on sensory stimulation of the human body by means of metal needles. The exact underlying mechanisms of acupuncture have not been clarified so far. Functional magnetic resonance imaging (fMRI has become an important tool in acupuncture research. Standard acupuncture needles, which are made of ferromagnetic steel, however, are problematic in acupuncture-fMRI studies for several reasons, such as attraction by the scanner's magnetic field, significant image distortions and signal-dropouts, when positioned close to the head or even heating due to absorption of radio frequency (RF. The aim of this study was to compare two novel types of acupuncture needles with a standard needle for their effect on MRI image quality. The standard needle severely reduced image quality, when located inside the RF coil. The nonferromagnetic metal needle may pose a risk due to RF heating, while the plastic needle has a significantly larger diameter. In conclusion, our recommendations are: (1 standard needles should not be used in MRI; (2 Nonferromagnetic metal needles seem to be the best choice for acupoints outside of the transmitter coil; and (3 only plastic needles are suited for points inside the coil. Laser acupuncture may be a safe alternative, too.

  7. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to pierce the skin in the practice of acupuncture. The device consists of a solid, stainless steel needle. The...

  8. Missing needle during episiotomy repair

    Directory of Open Access Journals (Sweden)

    Joydeb Roychowdhury

    2008-01-01

    Full Text Available Breakage and missing of the episiotomy needle is not uncommon occurrence at the hands of the junior doctors. Retrieving it from deeper tissue planes following its migration can be a challenging task.

  9. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  10. Homogeneity of δ15N in needles of Masson pine (Pinus massoniana L.) was altered by air pollution

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Li Jiong; Sun Fangfang; Hou Enqing; Zhou Guoyi; Zhang Deqiang; Huang Longbin

    2010-01-01

    The present study investigated the changes of δ 15 N values in the tip, middle and base section (divided by the proportion to needle length) of current- and previous-year needles of Masson pine (Pinus massoniana L.) from two declining forest stands suffering from air pollution, in comparison with one healthy stand. At the healthy stand, δ 15 N in the three sections of both current- and previous-year needles were found evenly distributed, while at the polluted stands, δ 15 N values in the needles were revealed significantly different from the tip to the base sections. The results implied that the distribution of δ 15 N among different parts or sections in foliages was not always homogeneous and could be affected by air pollution. We suggested that the difference of δ 15 N values among pine needle sections should be reconsidered and should not be primarily ignored when the needle δ 15 N values were used to assess plant responses to air pollution. - Values of δ 15 N in needles of Masson pine (Pinus massoniana L.) were uneven and affected by air pollution.

  11. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  12. SU-E-T-507: Interfractional Variation of Fiducial Marker Position During HDR Brachytherapy with Cervical Interstitial Needle Template

    Energy Technology Data Exchange (ETDEWEB)

    Shen, S; Kim, R; Benhabib, S; Araujo, J; Burnett, L; Duan, J; Popple, R; Wu, X; Cardan, R; Brezovich, I [UniversityAlabama Birmingham, Birmingham, AL (United Kingdom)

    2014-06-01

    Purpose: HDR brachytherapy using interstitial needle template for cervical cancer is commonly delivered in 4-5 fractions. Routine verification of needle positions before each fraction is often based on radiographic imaging of implanted fiducial markers. The current study evaluated interfractional displacement of implanted fiducial markers using CT images. Methods: 9 sequential patients with cervical interstitial needle implants were evaluated. The superior and inferior borders of the target volumes were defined by fiducial markers in planning CT. The implant position was verified with kV orthogonal images before each fraction. A second CT was acquired prior 3rd fraction (one or 2 days post planning CT). Distances from inferior and superior fiducial markers to pubic symphysis plane (perpendicular to vaginal obtulator)were measured. Distance from needle tip of a reference needle (next to the inferior marker) to the pubic symphysis plane was also determined. The difference in fiducial marker distance or needle tip distance between planning CT and CT prior 3rd fraction were measured to assess markers migration and needle displacement. Results: The mean inferior marker displacement was 4.5 mm and ranged 0.9 to 11.3 mm. The mean superior marker displacement was 2.7 mm and ranged 0 to 10.4 mm. There was a good association between inferior and superior marker displacement (r=0.95). Mean averaged inferior and superior marker displacement was 3.3 mm and ranged from 0.1 to 10.9 mm, with a standard deviation of 3.2 mm. The mean needle displacement was 5.6 mm and ranged 0.2 to 15.6 mm. Needle displacements were reduced (p<0.05) after adjusting according to needle-to-fiducials distance. Conclusion: There were small fiducial marker displacements between HDR fractions. Our study suggests a target margin of 9.7 mm to cover interfractional marker displacements (in 95% cases) for pretreatment verification based on radiographic imaging.

  13. Atom sharp needles, the missing link in microneedle drug delivery

    NARCIS (Netherlands)

    Wissink, J.; Berenschot, Johan W.; Tas, Niels Roelof

    2008-01-01

    The skin barrier function is a major challenge for delivery of drugs via the skin. Located in the outermost layer of the skin, the stratum corneum (SC) consists of dead cells embedded in lipid regions, only 10-20 microm thick, tough but flexible and elastic. Hyperdermic needles penetrate the skin

  14. Sewing needle foreign body ingestion in dogs and cats: 65 cases (2000-2012).

    Science.gov (United States)

    Pratt, Chap L; Reineke, Erica L; Drobatz, Kenneth J

    2014-08-01

    To characterize clinical signs, diagnostic test results, foreign body location, treatment, and outcome for dogs and cats with sewing needle foreign bodies. Retrospective case series. 65 dogs and cats with sewing needle foreign bodies. Medical records of 27 dogs and 38 cats examined because of sewing needle foreign bodies from January 2000 to February 2012 were reviewed for signalment, medical history, physical examination findings, diagnostic test results, interval from witnessed exposure and radiographic imaging to definitive treatment, definitive treatment, sewing needle location, complications, and outcome. 7 (10.8%) animals had sewing needles in extragastrointestinal locations that were not causing clinical signs. The remaining 58 (89.2%) animals had known sewing needle exposure or acute clinical signs associated with ingestion. The esophageal and gastric regions were the most common location for a sewing needle (10/21 [47.6%] dogs; 19/37 [51.4%] cats), followed by the oropharynx (7/21 [33.3%] dogs; 11/37 [29.7%] cats) and small and large intestines (4/21 [19.0%] dogs; 7/37 [18.9%] cats). Gastrointestinal perforation was detected in 10 of 58 (17.2%) animals (5/21 [23.8%] dogs; 5/37 [13.5%] cats). Sewing needles in the esophagus and stomach were successfully removed endoscopically in 8 of 9 dogs and 18 of 19 cats. Survival rate was 98.1% (51/52) for animals receiving definitive treatment. Endoscopic removal of ingested sewing needles was highly successful and should be recommended to prevent gastrointestinal tract perforation and associated morbidity. Prognosis for dogs and cats receiving definitive treatment for sewing needle foreign body ingestion was excellent.

  15. Presentation of a needle for direct or percutaneous myocardium stem cells injection

    Directory of Open Access Journals (Sweden)

    Nathan Valle Soubihe Junior

    2013-09-01

    Full Text Available The instrument has a locking mechanism and is composed of an external needle with blunt tip, with multiple 0.5 mm diameter holes. Internally it is fitted with a mandrill needle, which can be mobilized inside occluding or releasing the lateral holes. The procedure for producing micro lesions is done by exchanging the blunt mandrill for a brush-mandrill, provided with micro bristles that are structurally designed to fill the holes with small exteriorization of bristles. As an option to brush mandrill there is a second self-expandable feather shaped mandrill.

  16. Tips from the Classroom.

    Science.gov (United States)

    Wilhelm, Kim Hughes; Leverett, Thomas; Barrett, Rob J.; Chur-Hansen, Anna; Dantas-Whitney, Maria; Zapata, Gabriela; Garcia, Juan Felix

    1998-01-01

    Five articles present tips for rallying English-as-a-Second-Language students to the enterprise of creating context, tools, and language itself. The articles focus on using original dramas created by students, teaching nonnative English-speaking medical students to comprehend their patients' colloquial language, conducting research with native…

  17. Air Travel Health Tips

    Science.gov (United States)

    ... Conditions Prevention and Wellness Staying Healthy Healthy Living Travel Occupational Health First Aid and Injury Prevention Crisis ... MoreDepression in Children and TeensRead MoreBMI Calculator International Travel: Tips for Staying HealthyTexting and DrivingTravel Needs for ...

  18. 10 Data Visualization Tips

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    communicated through the use of design choices. (as indicated in tip 8). 8. Use colour, size, and position to help the reader see what is important. Colour adds emphasis, highlights particular data points, and draws connections between graphs. The hue, value, and intensity of the colour are significant and may have cultural ...

  19. Sports Dehydration Safety Tips

    Science.gov (United States)

    Sports Dehydration Safety Tips Everything you need to know to keep your kids safe from dehydration when playing sports. To keep kids in top ... to stay hydrated by drinking plenty of fluids. Dehydration occurs when a body loses more water than ...

  20. Spruce needles used as radioecological biotracers; Fichtennadeln als radiooekologische Bioindikatoren

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, C.; Gruber, V.; Baumgartner, A. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; Idinger, J. [Technische Univ. Wien (Austria). Atominst.; Fuerst, A. [BFW - Bundesforschungs- und Ausbildungszentrum fuer Wald, Naturgefahren und Landschaft, Wien (Austria). Inst. fuer Waldschutz, Pflanzenanalyse; Maringer, F.J. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; BEV - Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    2009-07-01

    In a two years project spruce needle samples of the Austrian Bioindicator Grid were analysed by gamma-ray spectrometry to investigate the spatial and temporal distribution of radionuclides in spruce needles of the last 25 years with the main focus on the radioactive contamination before and after the Chernobyl fallout 1986. More than 600 spruce needle samples at selected locations of the Bioindicator Grid were analysed for different natural and anthropogenic radionuclides: {sup 137}Cs, {sup 40}K, {sup 210}Pb, {sup 226}Ra, {sup 228}Ra, {sup 238}U. Additionally, soil samples were taken at selected sites to study the soil-to-plant transfer. This radioecological evaluation is an important part of an existing environmental surveillance programme in Upper Austria in order to gain basic information on the impact of environmental changes on the radioecological behaviour of spruce trees. (orig.)

  1. Performance Accuracy of Hand-on-needle versus Hand-onsyringe Technique for Ultrasound-guided Regional Anesthesia Simulation for Emergency Medicine Residents

    Directory of Open Access Journals (Sweden)

    Brian Johnson

    2014-09-01

    Full Text Available Introduction: Ultrasound-guided nerve blocks (UGNB are increasingly used in emergency care. The hand-on-syringe (HS needle technique is ideally suited to the emergency department setting because it allows a single operator to perform the block without assistance. The HS technique is assumed to provide less exact needle control than the alternative two-operator hand-on-needle (HN technique; however this assumption has never been directly tested. The primary objective of this study was to compare accuracy of needle targeting under ultrasound guidance by emergency medicine (EM residents using HN and HS techniques on a standardized gelatinous simulation model. Methods: This prospective, randomized study evaluated task performance. We compared needle targeting accuracy using the HN and HS techniques. Each participant performed a set of structured needling maneuvers (both simple and difficult on a standardized partial-task simulator. We evaluated time to task completion, needle visualization during advancement, and accuracy of needle tip at targeting. Resident technique preference was assessed using a post-task survey. Results: We evaluated 60 tasks performed by 10 EM residents. There was no significant difference in time to complete the simple model (HN vs. HS, 18 seconds vs. 18 seconds, p=0.93, time to complete the difficult model (HN vs. HS, 56 seconds vs. 50 seconds, p=0.63, needle visualization, or needle tip targeting accuracy. Most residents (60% preferred the HS technique. Conclusion: For EM residents learning UGNBs, the HN technique was not associated with superior needle control. Our results suggest that the single-operator HS technique provides equivalent needle control when compared to the two-operator HN technique. [West J Emerg Med. 2014;15(6:641–646

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS. top of page What are some common uses of the procedure? A TIPS is used to ... the scanner by a cord. Some exams may use different transducers (with different capabilities) during a single ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... or bypass, without the risks that accompany open surgery. TIPS is a minimally invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of an effect ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... then placed in this tunnel to keep the pathway open. Patients who typically need a TIPS have ... and stomach. A TIPS procedure involves creating a pathway through the liver that connects the portal vein ( ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and/or hydrothorax (in the chest). Budd-Chiari syndrome , a blockage in one or more veins that ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in ... TIPS reroutes blood flow in the liver and reduces abnormally high blood pressure in the veins of ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... What are the limitations of TIPS? What is a Transjugular Intrahepatic Portosystemic Shunt (TIPS)? A transjugular intrahepatic ... taking our brief survey: Survey Do you have a personal story about radiology? Share your patient story ...

  8. Guide for the realization of core needle biopsy through stereotaxy in the diagnosis of suspicious breast lesions of malignity

    International Nuclear Information System (INIS)

    Jimenez Zuniga, Jorge Luis

    2012-01-01

    Guides have been made for the realization of breast biopsies through stereotaxy in the management of breast lesions. The type of injuries that have been detected in mammography services, most have corresponded to nonpalpable lesions, that should be clarified through the take samples for an histological study with the purpose of categorize them. A bibliographic review was realized of the findings most frequent in the breast pathology. Also, before a nonpalpable breast lesion that requires a diagnosis biopsy, should be assessed the method of suitable guide for to access the same. The interventionist procedures of the breast have been developed in last years and have been guided by stereotaxy, in order to preoperative localization of these lesions or for obtaining valid cytologic-histologic material to reach a diagnosis, as it has often been difficult to differentiate, just for the image, between benign and malignant lesions. Thus, has emerged the necessity to guide the needle tip objectifying the lesion through mammography. A localization system based on triangulation is applied. The location of the lesion is calculated in the three axes of space (X, Y and Z) with a minimum error. The stereotactic devices have created to guide needles to injuries from a unique projection. This has allowed that breast and lesion are subject on a site while have taken samples several times. The complete mammography study that include the projections craniocaudal (CC) and mediolateral oblique (MLO) are analyzed to find out exactly on which quadrant has found the injury. Sometimes, the injury only has observed in a unique projection which is used for locating. The two main devices that have been used to perform stereotactic biopsy are automatic gun of biopsy and vacuum-assisted directional biopsy. Automatic gun of biopsy has used a long needle tru-cut type, with calibers between 18 and 14, although it is preferred 14-gauge needles. Multiple samples obtained from this needle have

  9. Transbronchial needle aspiration "by the books"

    Directory of Open Access Journals (Sweden)

    Kupeli Elif

    2011-01-01

    Full Text Available Background : Training for advanced bronchoscopic procedures is acquired during the interventional pulmonology (IP Fellowship. Unfortunately a number of such programs are small, limiting dissemination of formal training. Objective : We studied success of conventional transbronchial needle aspiration (C-TBNA in the hands of physicians without formal IP training. Methods : A technique of C-TBNA was learned solely from the literature, videos and practicing on inanimate models at "Hands-On" courses. Conventional TBNA with 21 and/or 19 gauge Smooth Shot Needles (Olympus® , Japan was performed on consecutive patients with undiagnosed mediastinal lymphadenopathy. Results : Thirty-four patients (male 23, mean age 54.9 ± 11.8 years underwent C-TBNA. Twenty-two patients had nodes larger than 20 mms. Suspected diagnoses were malignancy in 20 and nonmalignant conditions in 14. Final diagnoses were malignancy 17, sarcoidosis 4, reactive lymph nodes 12, and tuberculosis 1. Final diagnosis was established by C-TBNA in 14 (11 malignancy, 3 sarcoidosis; yield 41.1%, mediastinoscopy in 14, transthoracic needle aspiration in 3, peripheral lymph node biopsies in 2 and by endobronchial biopsy in 1. Nodal size had an impact on outcome (P = 0.000 while location did not (P = 0.33. C-TBNA was positive in 11/20 when malignancy was suspected (yield 55%, while 3/14 when benign diagnosis was suspected (yield 21.4% (P = 0.05. Sensitivity, specificity, PPV, NPV, and diagnostic accuracy were 66.6%, 100%, 100%, 65%, and 79.4%, respectively. There were no complications or scope damage. Conclusion : Conventional-TBNA can be learned by the books and by practicing on inanimate models without formal training and results similar to those published in the literature could be achieved.

  10. Efficacy of Tuohy Needle in Oocytes Collection from Excised Mare Ovaries

    Directory of Open Access Journals (Sweden)

    F. Cremonesi

    2010-01-01

    Full Text Available Two methods have been described to recover oocytes from equine follicles in excised ovaries: aspiration and scraping. Aim of this work was to develop an effective method for collecting equine oocytes using Tuohy needle and comparing this technique to aspiration and scraping, with or without tunica albuginea removal. This hollow hypodermic needle, usually employed for inserting epidural catheters, is designed with a slightly curved tip, shaped similar to a small curette. In unpeeled ovaries, the recovery rates of Tuohy needle group was higher (<.05 than in the 16 g needle aspiration and in the scraped ovaries (57% versus 36% and 47% while the rate of cumulus-intact oocytes was higher than aspiration (46.9% versus 39.36% but lower than scraping (46.97% (<.001. In unpeeled ovaries there was significant difference in maturation rate of oocytes recovered by Tuohy needle in respect to peeled ovaries (58.54% versus 50.17%, resp.. Combination of aspiration and scraping by Tuohy needle allows a faster and reliable collection of oocytes suitable for horse IVM.

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... liver disease are at greater risk for worsening liver failure after TIPS. If your liver failure is severe, a TIPS may not be the best use and a different procedure may be needed to control your symptoms. ... ordinarily filtered out by the liver. The TIPS may cause too much of these ...

  12. A microfluidic needle for sampling and delivery of chemical signals by segmented flows

    Science.gov (United States)

    Feng, Shilun; Liu, Guozhen; Jiang, Lianmei; Zhu, Yonggang; Goldys, Ewa M.; Inglis, David W.

    2017-10-01

    We have developed a microfluidic needle-like device that can extract and deliver nanoliter samples. The device consists of a T-junction to form segmented flows, parallel channels to and from the needle tip, and seven hydrophilic capillaries at the tip that form a phase-extraction region. The main microchannel is hydrophobic and carries segmented flows of water-in-oil. The hydrophilic capillaries transport the aqueous phase with a nearly zero pressure gradient but require a pressure gradient of 19 kPa for mineral oil to invade and flow through. Using this device, we demonstrate the delivery of nanoliter droplets and demonstrate sampling through the formation of droplets at the tip of our device. During sampling, we recorded the fluorescence intensities of the droplets formed at the tip while varying the concentration of dye outside the tip. We measured a chemical signal response time of approximately 3 s. The linear relationship between the recorded fluorescence intensity of samples and the external dye concentration (10-40 μg/ml) indicates that this device is capable of performing quantitative, real-time measurements of rapidly varying chemical signals.

  13. Comparision of Fine Needle Aspiration Cytology and Fine Needle ...

    African Journals Online (AJOL)

    Background: Open biopsy of the breast used to be the main traditional method of diagnosis of breast lumps. Fine Needle Aspiration Cytology (FNAC) was later introduced which depends on suction and thus yields hemorrhagic material for cytological study.This study was undertaken to find out if there is a difference in ...

  14. Tip-modified Propellers

    DEFF Research Database (Denmark)

    Andersen, Poul

    1999-01-01

    The paper deals with tip-modified propellers and the methods which, over a period of two decades, have been applied to develop such propellers. The development is driven by the urge to increase the efficiency of propellers and can be seen as analogous to fitting end plates and winglets to aircraft...... propeller, have efficiency increases of a reasonable magnitude in both open-water and behind-ship conditions....

  15. Histological observation for needle-tissue interactions.

    Science.gov (United States)

    Nakagawa, Yoshiyuki; Koseki, Yoshihiko

    2013-01-01

    We histologically investigated tissue fractures and deformations caused by ex vivo needle insertions. The tissue was formalin-fixed while the needle remained in the tissue. Following removal of the needle, the tissue was microtomed, stained, and observed microscopically. This method enabled observations of cellular and tissular conditions where deformations caused by needle insertions were approximately preserved. For this study, our novel method presents preliminary findings related with tissue fractures and the orientation of needle blade relative to muscle fibers. When the needle blade was perpendicular to the muscle fiber, transfiber fractures and relatively large longitudinal deformations occurred. When the needle blade was parallel to the muscle fiber, interfiber fractures and relatively small longitudinal deformations occurred. This made a significant difference in the resistance force of the needle insertions.

  16. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various ...

  17. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  18. Development of a Silicon Microneedle with Three-Dimensional Sharp Tip by Electrochemical Etching

    Science.gov (United States)

    Izumi, Hayato; Okamoto, Tokusuke; Suzuki, Masato; Aoyagi, Seiji

    Aiming at the use in low-invasive medical treatments, this paper reports a fabrication technique of silicon microneedle of conical sharp point. The electrochemical etching technique is employed for sharpening the tip of a pillar, which is diced from a silicon wafer. A finely smooth tip surface is obtained due to electrochemical etching reactions, and is effective for easy insertion. The fabrication method is based on inexpensive wet etching, which does not require expensive fabrication facilities such as deep reactive ion etching (DRIE). A sharp needle was successfully fabricated, the tip angle of which was considerably small and was distributed within the range from 15 to 30 deg. An experiment of inserting the fabricated needle into an artificial skin of silicone rubber was carried out. As the results, the resistance force during insertion was much reduced compared to those of two-dimensional sharp needles. Imitating mosquito's motion, the effectiveness of applying vibration to the fabricated needle during insertion was also confirmed. After biocompatible Parylene coating, puncturing a human skin was demonstrated assuming a lancet usage for the diabetics, in which the bleeding was surely observed.

  19. Case of an intrahepatic sewing needle and review of the literature.

    Science.gov (United States)

    Bostancı, Özgür; İdiz, Ufuk Oğuz; Battal, Muharrem; Kaya, Cemal; Mihmanlı, Mehmet

    2017-01-01

    An intrahepatic foreign body (FB) is rarely observed. In most cases, object passes from the gastrointestinal tract to the liver via migration. Uncomplicated intrahepatic FB can be followed without surgical intervention; however, complicated intrahepatic FB requires laparoscopy or laparotomy. Presently described is laparoscopic operation on 22-year-old female patient who had incidental sewing needle in the right liver lobe. As there were initially no complications, follow-up monitoring was recommended. However, the patient subsequently complained of stomach pain and developed fever. Laparoscopic exploration located sewing needle in the right liver lobe lateral to the gall bladder with end of needle protruding from the liver. Needle was removed with laparoscopic grasper. Review of the literature regarding 23 other intrahepatic sewing needle cases is also presented.

  20. Dry needling — peripheral and central considerations

    OpenAIRE

    Dommerholt, Jan

    2011-01-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects...

  1. KINEMATICS FRICTION PAIR FOR EXAMPLE NEEDLE BEARINGS

    OpenAIRE

    Jerzy NACHIMOWICZ; Robert KORBUT

    2014-01-01

    The present study concerns certain phenomena that take place in the needle roller bearing. The friction that generates the anti-torque of a friction pair is the major factor that influences the needle bearing’s wear. In the needle bearing there occur two predominant types of friction: the rolling friction and the sliding friction, and both are subject to examination. The study presents recordings and analysis of the movements of all needle bearing’s rolling elements. The examination was carri...

  2. Autosizing Control Panel for Needle Bearing

    OpenAIRE

    Prof.A.R.Wadhekar,; Ms Jyoti R. Rajput

    2016-01-01

    A needle roller bearing is a bearing which uses small cylindrical rollers. Bearings are used to reduce friction of any rotating surface. Needle bearings have a large surface in contact with the bearing outer surfaces as compared to ball bearings. There is less added clearance(Diameter of the shaft and the diameter of the bearing are different) so they are much compact. The structure consists of a needle cage which contains the needle rollersthemselves and an outer race (The housin...

  3. Sewing needles in the brain: infanticide attempts or accidental insertion?

    Science.gov (United States)

    Sturiale, Carmelo Lucio; Massimi, Luca; Mangiola, Annunziato; Pompucci, Angelo; Roselli, Romeo; Anile, Carmelo

    2010-10-01

    Placing of sewing needles in the brain through the anterior fontanelle was first described in Germany in 1914. Forty cases have been reported in the scientific literature; most of them were identified in Turkey and Iran, with only a few cases in the Far East, North and Eastern Europe, and the United States. The only case observed in Italy was recorded in 1987. In nonmedical literature, this practice was frequently described in Persian novels, and it has been thought that this ritual could have been diffused with the Persian Empire domination over the centuries. We report on a new Italian case of an 82-year-old woman admitted for progressive right hemiparesis and gait disturbance. Brain computed tomography scan showed a left frontoparietal chronic subdural haematoma and, surprisingly, three 4-cm-long sewing needles inserted through the region of the anterior fontanelle. The patient and her friends and family did not remember any event justifying their presence. Subdural collection was evacuated by craniotomic approach, and the sewing needles were left in place and followed up. The rare cases of intracranial needling reported in the literature may represent only the tip of the iceberg. The phenomenon is usually reported as an incidental finding in asymptomatic adults, whereas many babies could not have been diagnosed because they died. The therapy remains controversial, although many authors suggest only follow-up for asymptomatic patients. In this article, all the pertinent literature is reviewed and the most important clinical aspects are discussed, along with a historical assessment of the problem.

  4. Evidence and expert opinions: Dry needling versus acupuncture (II) : The American Alliance for Professional Acupuncture Safety (AAPAS) White Paper 2016.

    Science.gov (United States)

    Fan, Arthur Yin; Xu, Jun; Li, Yong-Ming

    2017-02-01

    In the United States and other Western countries, dry needling has been a topic in academic and legal fields. This White Paper is to provide the authoritative information of dry needling versus acupuncture to academic scholars, healthcare professionals, administrators, policymakers, and the general public by providing the authoritative evidence and expertise regarding critical issues of dry needling and reaching a consensus. We conclude that Dr. Travell, Dr. Gunn, Dr. Baldry and others who have promoted dry needling by simply rebranding (1) acupuncture as dry needling and (2) acupuncture points as trigger points (dry needling points). Dry needling simply using English biomedical terms (especially using "fascia" hypothesis) in replace of their equivalent Chinese medical terms. Dry needling is an over-simplified version of acupuncture derived from traditional Chinese acupuncture except for emphasis on biomedical language when treating neuromuscularskeletal pain (dry needling promoters redefined it as "myofascial pain"). Trigger points belong to the category of Ashi acupuncture points in traditional Chinese acupuncture, and they are not a new discovery. By applying acupuncture points, dry needling is actually trigger point acupuncture, an invasive therapy (a surgical procedure) instead of manual therapy. Dr. Travell admitted to the general public that dry needling is acupuncture, and acupuncture professionals practice dry needling as acupuncture therapy and there are several criteria in acupuncture profession to locate trigger points as acupuncture points. Among acupuncture schools, dry needling practitioners emphasize acupuncture's local responses while other acupuncturists pay attention to the responses of both local, distal, and whole body responses. For patients' safety, dry needling practitioners should meet standards required for licensed acupuncturists and physicians.

  5. Rhizosphaera Needle Disease of Fir

    Science.gov (United States)

    Mike Albers; Jana Albers; Jane Cummings-Carlson; Linda Haugen; Nancy Wenner

    1996-01-01

    Rhizosphaera pini is a common plant pathogen in the Lake States, Northeastern States and Canada. A closely related pathogen, Rhizosphaera kalkhoffii, causes a common needle blight on spruce and other conifers. R. pini is often considered to be a weak pathogen, occurring on stressed foliage or foliage killed by other causes. However, it has been observed causing...

  6. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  7. Preliminary Design and Evaluation of a B-Scan OCT-Guided Needle

    Directory of Open Access Journals (Sweden)

    Karen M. Joos

    2014-09-01

    Full Text Available Real-time intraoperative B-scan optical coherence tomography (OCT visualization of intraocular tissues is a desired ophthalmic feature during retinal procedures. A novel intraocular 25-gauge B-mode forward-imaging OCT probe was combined with a 36-gauge needle into a prototype instrument. Imaging of the needle tip itself and the effects of saline injection into a gelatin phantom were performed. A combined B-scan forward-imaging OCT-needle prototype was capable of real-time-imaging of saline injection into a gelatin phantom. Additional future miniaturization may permit this instrument to be an adjunctive real-time imaging and procedure tool for vitreoretinal surgery.

  8. Transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma located in the subphrenic region of liver

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    2000-01-01

    The purpose of this study is to evaluate the feasibility of transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma (HCC, 15 lesions) located in the subphrenic region and untreatable by ultrasonography-guided PEIT. The HCC was localized on Lipiodol CT image with a graduated grid system. We advanced a PEIT needle in a stepwise fashion, perpendicularly to the major axis of body through the lung with intermittent localization scans to position the tip of the needle in the lesion. Ethanol was injected with monitoring scans obtained after incremental volumes of injection, until perfusion was judged to be complete. A total of 20 CT-PEIT sessions were performed. The average number of needles passed from skin to liver in each CT-PEIT session was 2.7, the average volume of ethanol injected was 11.7 ml, and the average time required was 53.6 minutes. Complete perfusion of the lesion by ethanol was achieved in all lesions with only a single or double CT-PEIT procedure without severe complications. Local recurrence was detected in 3 to 15 followed up lesions for 14 months on average. In conclusion, transpulmonary CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC located in the subphrenic region. (author)

  9. Endophyte communities vary in the needles of Norway spruce clones.

    Science.gov (United States)

    Rajala, Tiina; Velmala, Sannakajsa M; Tuomivirta, Tero; Haapanen, Matti; Müller, Michael; Pennanen, Taina

    2013-03-01

    Endophytic fungi show no symptoms of their presence but can influence the performance and vitality of host trees. The potential use of endophytes to indicate vitality has been previously realized, but a standard protocol has yet to be developed due to an incomplete understanding of the factors that regulate endophyte communities. Using a culture-free molecular approach, we examined the extent to which host genotype influences the abundance, species richness, and community composition of endophytic fungi in Norway spruce needles. Briefly, total DNA was extracted from the surface-sterilized needles of 30 clones grown in a nursery field and the copy number of the fungal internal transcribed spacer (ITS) region of ribosomal DNA was estimated by quantitative PCR. Fungal species richness and community composition were determined by denaturing gradient gel electrophoresis and DNA sequencing. We found that community structure and ITS copy number varied among spruce clones, whereas species richness did not. Host traits interacting with endophyte communities included needle surface area and the location of cuttings in the experimental area. Although Lophodermium piceae is considered the dominant needle endophyte of Norway spruce, we detected this species in only 33% of samples. The most frequently observed fungus (66%) was the potentially pathogenic Phoma herbarum. Interestingly, ITS copy number of endophytic fungi correlated negatively with the richness of ectomycorrhizal fungi and thus potential interactions between fungal communities and their influence on the host tree are discussed. Our results suggest that in addition to environmental factors, endophyte communities of spruce needles are determined by host tree identity and needle surface area. Copyright © 2013 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  10. Dry needling: a literature review with implications for clinical practice guidelines.

    Science.gov (United States)

    Dunning, James; Butts, Raymond; Mourad, Firas; Young, Ian; Flannagan, Sean; Perreault, Thomas

    2014-08-01

    Wet needling uses hollow-bore needles to deliver corticosteroids, anesthetics, sclerosants, botulinum toxins, or other agents. In contrast, dry needling requires the insertion of thin monofilament needles, as used in the practice of acupuncture, without the use of injectate into muscles, ligaments, tendons, subcutaneous fascia, and scar tissue. Dry needles may also be inserted in the vicinity of peripheral nerves and/or neurovascular bundles in order to manage a variety of neuromusculoskeletal pain syndromes. Nevertheless, some position statements by several US State Boards of Physical Therapy have narrowly defined dry needling as an 'intramuscular' procedure involving the isolated treatment of 'myofascial trigger points' (MTrPs). To operationalize an appropriate definition for dry needling based on the existing literature and to further investigate the optimal frequency, duration, and intensity of dry needling for both spinal and extremity neuromusculoskeletal conditions. According to recent findings in the literature, the needle tip touches, taps, or pricks tiny nerve endings or neural tissue (i.e. 'sensitive loci' or 'nociceptors') when it is inserted into a MTrP. To date, there is a paucity of high-quality evidence to underpin the use of direct dry needling into MTrPs for the purpose of short and long-term pain and disability reduction in patients with musculoskeletal pain syndromes. Furthermore, there is a lack of robust evidence validating the clinical diagnostic criteria for trigger point identification or diagnosis. High-quality studies have also demonstrated that manual examination for the identification and localization of a trigger point is neither valid nor reliable between-examiners. Several studies have demonstrated immediate or short-term improvements in pain and/or disability by targeting trigger points (TrPs) using in-and-out techniques such as 'pistoning' or 'sparrow pecking'; however, to date, no high-quality, long-term trials supporting in

  11. The 3DBiopsy Prostate Biopsy System: Preclinical Investigation of a Needle, Actuator, and Specimen Collection Device Allowing Sampling of Individualized Prostate Lengths Between 20 and 60 mm.

    Science.gov (United States)

    Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David

    2017-09-01

    To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Tipping point leadership.

    Science.gov (United States)

    Kim, W Chan; Mauborgne, Renée

    2003-04-01

    When William Bratton was appointed police commissioner of New York City in 1994, turf wars over jurisdiction and funding were rife and crime was out of control. Yet in less than two years, and without an increase in his budget, Bratton turned New York into the safest large city in the nation. And the NYPD was only the latest of five law-enforcement agencies Bratton had turned around. In each case, he succeeded in record time despite limited resources, a demotivated staff, opposition from powerful vested interests, and an organization wedded to the status quo. Bratton's turnarounds demonstrate what the authors call tipping point leadership. The theory of tipping points hinges on the insight that in any organization, fundamental changes can occur quickly when the beliefs and energies of a critical mass of people create an epidemic movement toward an idea. Bratton begins by overcoming the cognitive hurdles that block organizations from recognizing the need for change. He does this by putting managers face-to-face with operational problems. Next, he manages around limitations on funds, staff, or equipment by concentrating resources on the areas that are most in need of change and that have the biggest payoffs. He meanwhile solves the motivation problem by singling out key influencers--people with disproportionate power due to their connections or persuasive abilities. Finally, he closes off resistance from powerful opponents. Not every CEO has the personality to be a Bill Bratton, but his successes are due to much more than his personality. He relies on a remarkably consistent method that any manager looking to turn around an organization can use to overcome the forces of inertia and reach the tipping point.

  13. Suture techniques in nasal tip sculpture: current concepts.

    Science.gov (United States)

    Lo, S; Rowe-Jones, J

    2007-08-01

    The three-dimensional anatomy and conspicuous location of the nasal tip makes it one of the most challenging sites of facial plastic surgery. This article reviews literature on nasal tip sculpture using suture techniques, as well as the authors' own experience. A search was conducted using Pubmed, the Google internet search engine and the authors' files, using the keywords 'nasal tip', 'suture', 'rhinoplasty' and 'septorhinoplasty'. Common nasal tip suture techniques and suture algorithms are presented, along with a summary of the indications and side effects of each technique. Predictable long-term results are more likely to occur with minimal local tissue excision. Suture techniques remodel the shape of the nasal tip by altering the configuration of, and the relationship between, the tip cartilages and their supporting structures; they also preserve nasal tip anatomy and limit resection. Intra-operatively, the effects are immediately visible, and can be adjusted or reversed. Tip sutures should therefore be considered instead of tissue excision whenever possible.

  14. Blunt needle revision with viscoelastic materials via the anterior chamber for early failed filtering blebs after trabeculectomy

    Directory of Open Access Journals (Sweden)

    Yamagami H

    2012-06-01

    Full Text Available Nozomi Kinoshita, Ayumi Ota, Fumihiko Toyoda, Hiroko Yamagami, Akihiro KakehashiDepartment of Ophthalmology, Saitama Medical Center, Jichi Medical University, Saitama, JapanPurpose: To report a new technique of blunt needle revision with viscoelastic materials via the anterior chamber for the treatment of early failed filtering blebs and elevated intraocular pressure after trabeculectomy, in which digital ocular massage and laser suture lysis have been ineffective.Methods: A 27-gauge blunt needle attached to a syringe containing viscoelastic material was inserted into the anterior chamber from the inferior paracentesis. The needle tip was inserted into the subscleral flap space from the filtering fistula at the anterior chamber side, and the scleral flap was lifted bluntly. The needle tip was then inserted into the subconjunctival space where the viscoelastic agent was injected and the adhesion between the sclera and conjunctiva was separated bluntly. Blunt needle revision via the anterior chamber was performed 14 times in six eyes of six patients at Saitama Medical Center, Jichi Medical University from January 2007 to May 2009. All procedures were performed within 1 month after trabeculectomy.Results: The intraocular pressure remained 21 mmHg or lower for more than 6 months in three of six eyes. Slight bleeding from the iris occurred in one of the 14 procedures, and hypotony (intraocular pressure below 5 mmHg occurred in one of the 14 procedures. No serious complications developed.Conclusion: Blunt needle revision via the anterior chamber for early failed filtering blebs is a new, simple, and safe procedure.Keywords: glaucoma, trabeculectomy, filtering bleb, needle revision, blunt needle

  15. Microfabricated microneedle with porous tip for drug delivery

    Science.gov (United States)

    Ji, Jing; Tay, Francis E. H.; Miao, Jianmin; Iliescu, Ciprian

    2006-05-01

    This paper presents a novel approach to fabrication of a silicon microneedle array with porous tips. Dry etching technology with SF6/O2 gas by STS's inductively coupled plasma (ICP) etch tool was used to achieve the pyramidal needle structure. A thin silicon nitride layer was deposited after a thick photoresist layer was coated and reflowed at 120 °C. The silicon nitride layer and residual photoresist on the tips of the pyramidal structures were removed using reactive ion etching (RIE). Electrochemical etching in MeCN/HF was carried out to generate porous silicon on the tips of the microneedles. The fabricated microneedle array has potential applications in drug delivery, since the porous tips can be loaded with a high molecular weight drug. Analytic solutions to the critical loadings of the fabricated microneedle structure are also presented. The variations of the square cross-section were expressed as a function of the axial coordinate to analyze the bending normal stress and critical buckling loading. This analytic method can also be used for other microneedle structures with different cross-sections.

  16. Three-dimensional analysis of internal flow characteristics in the injection nozzle tip of direct-injection diesel engines; Sanjigen suchi kaiseki ni yoru DI diesel kikan no nenryo funsha nozzle nai ryudo tokusei no kaimei

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H.; Matsui, Y.; Kimura, S. [Nissan Motor Co. Ltd. Tokyo (Japan)

    1997-10-01

    To reduce the exhaust emissions and fuel consumption of direct-injection diesel engines, it is essential to optimize the fuel injection equipment closely related to combustion and emission characteristics. In this study, three-dimensional computation has been applied to investigate the effects of the injection nozzle specifications (e.g., sac volume, round shape at the inlet of the nozzle hole) and needle tip deviation on internal flow characteristics. The computational results revealed that the effects of the nozzle specifications and needle tip deviation with a smaller needle lift on internal flow characteristics and a general approach to optimize the injection nozzle specifications were obtained. 3 refs., 10 figs., 1 tab.

  17. Interesting case of a sewing needle inside the heart: report of a case.

    Science.gov (United States)

    Irdem, Ahmet; Baspinar, Osman; Gokaslan, Gokhan

    2015-04-01

    Despite being rarely seen, penetrating cardiac injuries are clinically significant, as they are highly lethal. We herein present the case of a 3-year-old male who unintentionally injured himself by pricking his own chest with a sewing needle and introducing it through the left-lower margin of his sternum into his right ventricle. The needle was located anterior-posteriorly over the right ventricle. An anterior thoracotomy was performed, and the needle was safely removed. No hemorrhage or arrhythmia was seen, so the operation was ended. An early diagnosis and intervention proved to be life-saving for this penetrating cardiac injury.

  18. AERODYNAMICS OF WING TIP SAILS

    Directory of Open Access Journals (Sweden)

    MUSHTAK AL-ATABI

    2006-06-01

    Full Text Available Observers have always been fascinated by soaring birds. An interesting feature of these birds is the existence of few feathers extending from the tip of the wing. In this paper, small lifting surfaces were fitted to the tip of a NACA0012 wing in a fashion similar to that of wing tip feathers. Experimental measurements of induced drag, longitudinal static stability and trailing vortex structure were obtained.The tests showed that adding wing tip surfaces (sails decreased the induced drag factor and increased the longitudinal static stability. Results identified two discrete appositely rotated tip vortices and showed the ability of wing tip surfaces to break them down and to diffuse them.

  19. Phenolic compounds distribution along the lenght of Scots pine needles in a polluted and control environment and its connection with necroses formation

    Directory of Open Access Journals (Sweden)

    Marian J. Giertych

    2014-01-01

    Full Text Available Phenolic compounds distribution was studied along the length of Scots pine needles from trees in a polluted and a control site. There is no significant difference in the content of total phenols between the studied sites. There are significant differences in distribution of phenolics along the length of needles. The highest content is in the tip part of the needle and the lowest at the base. This kind of distribution suggests a role of these compounds in the processes of necroses formation. The content of phenolic compounds is positively correlated with the toxic elements - fluorine and aluminium and negatively with the macroelements - phosphorus, potassium and magnesium.

  20. Dry needling: a literature review with implications for clinical practice guidelines1

    Science.gov (United States)

    Dunning, James; Butts, Raymond; Mourad, Firas; Young, Ian; Flannagan, Sean; Perreault, Thomas

    2014-01-01

    Background: Wet needling uses hollow-bore needles to deliver corticosteroids, anesthetics, sclerosants, botulinum toxins, or other agents. In contrast, dry needling requires the insertion of thin monofilament needles, as used in the practice of acupuncture, without the use of injectate into muscles, ligaments, tendons, subcutaneous fascia, and scar tissue. Dry needles may also be inserted in the vicinity of peripheral nerves and/or neurovascular bundles in order to manage a variety of neuromusculoskeletal pain syndromes. Nevertheless, some position statements by several US State Boards of Physical Therapy have narrowly defined dry needling as an ‘intramuscular’ procedure involving the isolated treatment of ‘myofascial trigger points’ (MTrPs). Objectives: To operationalize an appropriate definition for dry needling based on the existing literature and to further investigate the optimal frequency, duration, and intensity of dry needling for both spinal and extremity neuromusculoskeletal conditions. Major findings: According to recent findings in the literature, the needle tip touches, taps, or pricks tiny nerve endings or neural tissue (i.e. ‘sensitive loci’ or ‘nociceptors’) when it is inserted into a MTrP. To date, there is a paucity of high-quality evidence to underpin the use of direct dry needling into MTrPs for the purpose of short and long-term pain and disability reduction in patients with musculoskeletal pain syndromes. Furthermore, there is a lack of robust evidence validating the clinical diagnostic criteria for trigger point identification or diagnosis. High-quality studies have also demonstrated that manual examination for the identification and localization of a trigger point is neither valid nor reliable between-examiners. Conclusions: Several studies have demonstrated immediate or short-term improvements in pain and/or disability by targeting trigger points (TrPs) using in-and-out techniques such as ‘pistoning’ or

  1. Tattoo machines, needles and utilities.

    Science.gov (United States)

    Rosenkilde, Frank

    2015-01-01

    Starting out as a professional tattooist back in 1977 in Copenhagen, Denmark, Frank Rosenkilde has personally experienced the remarkable development of tattoo machines, needles and utilities: all the way from home-made equipment to industrial products of substantially improved quality. Machines can be constructed like the traditional dual-coil and single-coil machines or can be e-coil, rotary and hybrid machines, with the more convenient and precise rotary machines being the recent trend. This development has resulted in disposable needles and utilities. Newer machines are more easily kept clean and protected with foil to prevent crosscontaminations and infections. The machines and the tattooists' knowledge and awareness about prevention of infection have developed hand-in-hand. For decades, Frank Rosenkilde has been collecting tattoo machines. Part of his collection is presented here, supplemented by his personal notes. © 2015 S. Karger AG, Basel.

  2. Emerging Needle Blight Diseases in Atlantic Pinus Ecosystems of Spain

    Directory of Open Access Journals (Sweden)

    Esther Ortíz de Urbina

    2016-12-01

    Full Text Available Red band needle blight caused by Dothistroma septosporum and D. pini, and brown spot needle blight caused by Lecanosticta acicola provoke severe and premature defoliation in Pinus, and subsequent reduction of photosynthetic surfaces, vitality, and growth in young and adult trees. The recurrent damage results in branch and tree death. Until recently, pine needle blight diseases have had only minor impacts on native and exotic forest trees in the North of Spain, but in the past five years, these pathogen species have spread widely and caused severe defoliation and mortality in exotic and native plantations of Pinus in locations where they were not detected before. In an attempt to understand the main causes of this outbreak and to define the effectiveness of owners’ management strategies, four research actions were implemented: a survey of the management activities implemented by the owners to reduce disease impact, the evaluation of specific symptoms and damage associated with infection, and the identification of the causative pathogenic species and their reproductive capacity. Morphological characteristics of the fungus and molecular identification were consistent with those of Lecanosticta acicola and Dothistroma spp., D. septosporum, D. Pini, and both mating types were present for the three identified pathogens. The local silvicultural management performed, mainly pruning and thinning, was not resulting in the expected improvement. The results of this study can be applied to establish guidelines for monitoring and controlling the spread of needle blight pathogens.

  3. 29 gauge needles improve patient satisfaction over 27 gauge needles for daily glatiramer acetate injections

    Directory of Open Access Journals (Sweden)

    Stephen Glenski

    2009-12-01

    Full Text Available Stephen Glenski, Jill ConnerMedical Affairs – Teva Neuroscience, Kansas City, MO, USAAbstract: Using three surveys, a comparative assessment of needle performance and patient preference for 27-gauge (G and 29G needles for glatiramer acetate administration for multiple sclerosis therapy was performed. Eligible patients participated in a specialty pharmacy program and administered glatiramer acetate for ≥1 month. In Survey 1 on the 27G needle, 545 (82.70% patients reported no needle problems, 106 (16.09% cited one type (dull, bent, or broken, five (0.76% cited two types, and three (0.46% cited all three types. In Survey 2 on the 29G needle, 553 (98.05% indicated no problems, two (0.35% cited dull needles, and nine (1.60% cited bent needles. On the 29G needles versus 27G needles pain comparison, 219 (38.83% reported the 29G needle was a little better, and 155 (27.48% reported it was a lot better than the 27G. For injection-site experiences, 515 patients (91.31% reported no, very slight, or mild reactions with the 29G needle. In Survey 3, over 76% of patients preferred the 29G to the 27G needle and significantly fewer patients reported one or more problems with the 29G needle compared to patients reporting problems with the 27G needle (P < 0.00001. In conclusion, significantly fewer patients reported problems after 30 days of use of the 29G than the 27G needle. Fewer injectionsite experiences occurred with the 29G needle and the 29G needle was preferred overall.Keywords: 29 gauge needle, subcutaneous injection, glatiramer acetate

  4. Hydraulic design of pine needles: one-dimensional optimization for single-vein leaves.

    Science.gov (United States)

    Zwieniecki, Maciej A; Stone, Howard A; Leigh, Andrea; Boyce, C Kevin; Holbrook, N Michele

    2006-05-01

    Single-vein leaves have the simplest hydraulic design possible, yet even this linear water delivery system can be modulated to improve physiological performance. We determined the optimal distribution of transport capacity that minimizes pressure drop per given investment in xylem permeability along the needle for a given length without a change in total water delivery, or maximizes needle length for a given pressure difference between petiole and needle tip. This theory was tested by comparative analysis of the hydraulic design of three pine species that differ in the length of their needles [Pinus palustris (Engl.) Miller, approximately 50 cm; Pinus ponderosa Lawson & Lawson, approximately 20 cm and Pinus rigida Miller, approximately 5 cm]. In all three species, the distribution of hydraulic permeability was similar to that predicted by the optimum solution. The needles of P. palustris showed an almost perfect match between predicted and actual hydraulic optimum solution, providing evidence that vein design is a significant factor in the hydraulic design of pine leaves.

  5. Comparison between marked versus unmarked introducer needle in real-time ultrasound-guided central vein cannulation: A prospective randomized study

    Directory of Open Access Journals (Sweden)

    Tanmoy Ghatak

    2016-01-01

    Full Text Available Introduction: Introducer needle tip is not clearly visible during the real-time ultrasound (US-guided central vein cannulation (CVC. Blind tip leads to mechanical complications. This study was designed to evaluate whether real-time US-guided CVC with a marked introducer needle is superior to the existing unmarked needle. Methodology: Sixty-two critically ill patients aged 18–60 years of either sex were included in the study. The patients were randomized into two groups based on whether a marked or unmarked introducer needle was used. Both groups underwent real-time US-guided CVC by a single experienced operator. Aseptically, introducer needle was indented with markings spaced 0.5 cm (single marking and every 1 cm (double marking. This needle was used in the marked group. Approximate depths (centimeter of the anterior and posterior wall of the internal jugular vein, anterior wall of the internal carotid artery, and lung pleura were appreciated from the midpoint of the probe in short-axis view at the level of the cricoid cartilage. Access time (seconds was recorded using a stopwatch. A number of attempts and complications such as arterial puncture, hematoma, and pneumothorax of either procedure were compared. Results: Both marked needle and unmarked needle groups were comparable with regard to age, gender, severity scores, platelet counts, prothrombin time, and distance from the midpoint of the probe to the vein, artery, and pleura and skin-to-guide wire insertion access time. However, an average number of attempts (P = 0.03 and complications such as hematoma were significantly lower (P = 0.02 with the marked introducer needle group. Pneumothorax was not reported in any of the groups.Conclusion: Our study supports the idea that marked introducer needle can further reduce the iatrogenic complications of US-guided CVC.

  6. The effect of injectate conductivity on the electric field with the nerve stimulator needle: a computer simulation.

    Science.gov (United States)

    Ercole, Ari

    2008-10-01

    Electrical neural stimulation is commonly used to localize neural structures and place local anesthetic for regional anesthesia. The sharp tip of the stimulating needle gives rise to an electric field which is highly localized. The electrostatic effect of the injected solution on the field distribution and strength has not previously been modeled. The three-dimensional electric field around a 0.7 mm diameter, un-insulated, hollow needle with a 30 degrees bevel was calculated in silico using a hybrid finite difference/impedance network method to solve the Laplace equation. The surrounding tissue was assumed to be electrically uniform. A sphere of injectate centered on the bevel was modeled as a region of conductivity differing from that of the bulk tissue. The electric field strength was highly concentrated at the needle tip and decayed rapidly with distance r approximately as 1/r1.7. It was demonstrated that the electric field in the immediate vicinity of the needle tip was greatly reduced in the presence of solutions with conductivity greater than that of the surrounding tissue. A 1.5 mm radius region of conducting solution (equivalent to saline or local anesthetics) reduced the field by 31%. The same volume of a relatively insulating injectate, such as dextrose solution, led to a field enhancement of approximately 15%. The electric field magnitude in the vicinity of the needle tip decayed more slowly with distance than predicted by Coulomb's law. This was independent of the presence of injectate. The near instantaneous abolition of muscle twitch with injection of small volumes of local anesthetic is consistent with an electrostatic effect, rather than a pharmacological or mechanical one. The change in field strength depended upon the volume of the injectate and its conductivity relative to that of the surrounding tissue. In this simulation, even tiny volumes of injectate lead to significant changes in field and therefore threshold current, which may have clinical

  7. Procedure-related complications of transjugular intrahepatic portosystemic shunt (TIPS) and its clinical significance

    International Nuclear Information System (INIS)

    Oh, Hyun Han; Byun, Kyung Hwan; Kim, Tae Gwon; Kang, Duk Sik; Kim, Yong Joo

    1995-01-01

    The purpose who to evaluate the procedure-related complications of the TIPS and its clinical significance. The materials consisted of 52 patients who had 57 TIPS procedures for the management of variceal bleeding due to portal hypertension. To detect the occurrence of complications during transhepatic needle puncture (from hepatic vein to the portal vein), contrast material was injected with the with drawl of the puncture needle. Procedure-related complications occurred in 28 patients (54%) among 52 patients. The complications were biliary tree puncture (15 cases), transperitoneal puncture (14 cases), stent malposition (3 cases), stent migration (1 case), hepatic arteries puncture (1 case), splenic vein perforation (1 case), and paroxysmal ventricular tachycardia (1 case). Three patients had acute stent thrombosis with rebleeding immediately after the procedure. The procedure was repeated in two patients. One patient was expired due to rebleeding. The procedure related complications were clinically insignificant in most instances, except when stent thrombosis or proxysmal ventricular tachycardia was developed

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... liver disease are at greater risk for worsening liver failure after TIPS. If your liver failure is severe, a TIPS may not be the ... children are more likely to be performed before liver transplant in those with ascites or variceal ... 08, 2017 Send us your feedback Did you find the ...

  9. Dry needling — peripheral and central considerations

    Science.gov (United States)

    Dommerholt, Jan

    2011-01-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects of central sensitization, it reduces local and referred pain, improves range of motion and muscle activation pattern, and alters the chemical environment of trigger points. Trigger point dry needling should be based on a thorough understanding of the scientific background of trigger points, the differences and similarities between active and latent trigger points, motor adaptation, and central sensitize application. Several outcome studies are included, as well as comments on dry needling and acupuncture. PMID:23115475

  10. Dry needling - peripheral and central considerations.

    Science.gov (United States)

    Dommerholt, Jan

    2011-11-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects of central sensitization, it reduces local and referred pain, improves range of motion and muscle activation pattern, and alters the chemical environment of trigger points. Trigger point dry needling should be based on a thorough understanding of the scientific background of trigger points, the differences and similarities between active and latent trigger points, motor adaptation, and central sensitize application. Several outcome studies are included, as well as comments on dry needling and acupuncture.

  11. Lamellar keratoplasty using position-guided surgical needle and M-mode optical coherence tomography

    Science.gov (United States)

    Shin, Sungwon; Bae, Jung Kweon; Ahn, Yujin; Kim, Hyeongeun; Choi, Geonho; Yoo, Young-Sik; Joo, Choun-Ki; Moon, Sucbei; Jung, Woonggyu

    2017-12-01

    Deep anterior lamellar keratoplasty (DALK) is an emerging surgical technique for the restoration of corneal clarity and vision acuity. The big-bubble technique in DALK surgery is the most essential procedure that includes the air injection through a thin syringe needle to separate the dysfunctional region of the cornea. Even though DALK is a well-known transplant method, it is still challenged to manipulate the needle inside the cornea under the surgical microscope, which varies its surgical yield. Here, we introduce the DALK protocol based on the position-guided needle and M-mode optical coherence tomography (OCT). Depth-resolved 26-gage needle was specially designed, fabricated by the stepwise transitional core fiber, and integrated with the swept source OCT system. Since our device is feasible to provide both the position information inside the cornea as well as air injection, it enables the accurate management of bubble formation during DALK. Our results show that real-time feedback of needle end position was intuitionally visualized and fast enough to adjust the location of the needle. Through our research, we realized that position-guided needle combined with M-mode OCT is a very efficient and promising surgical tool, which also to enhance the accuracy and stability of DALK.

  12. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  13. Processing and Characterization of Needled Carbon Composites

    Science.gov (United States)

    2015-12-01

    are found in the literature of needled/felted carbon-carbon (C/C) composites for high temperature applications such as ablative aerospace heat shields...carbon fibers themselves. Reductions in tensile strength of up to 25% for stitched carbon/ epoxy composites have been reported, as have drops in elastic...laminate plane. Previous work with needled glass/ epoxy composites has shown a 270% improvement in Mode I interlaminar fracture toughness when needled

  14. Preparation and examination of monolithic in-needle extraction (MINE) device for the direct analysis of liquid samples

    Energy Technology Data Exchange (ETDEWEB)

    Pietrzyńska, Monika, E-mail: monikapietrzynska@gmail.com; Voelkel, Adam; Bielicka-Daszkiewicz, Katarzyna

    2013-05-07

    Graphical abstract: -- Highlights: •MINE device for isolation of analytes from water samples. •Nine polymer poly(styrene-divinylbenzene) monoliths prepared in stainless steel needles. •High efficiency of in-needle extraction systems based on monolithic materials. •New possibilities in sample preparation area. -- Abstract: Combination of extraction and chromatographic techniques opens NEW possibilities in sample preparation area. Macroporous poly(styrene-divinylbenzene) (PS-DVB) monoliths were prepared by in situ polymerization in stainless steel needles. The surface of stainless steel needle was modified earlier by the silane coupling agent. Monolithic materials located inside needles were used as the in-needle extraction device. Scanning electron microscope (SEM) images were obtained for nine monoliths. Spectra of prepared materials were also performed with the use of two techniques: Attenuated Total Reflectance (ATR) and Fourier Transform Infrared Spectroscopy (FTIR). The new monolithic in-needle extraction (MINE) devices were used in the preparation of a series of test water samples for chromatographic analysis. The extraction of phenolic compounds from water samples was carried out by pumping liquid samples through the MINE device. Obtained results indicate a high efficiency of in-needle extraction systems based on monolithic materials. Breakthrough volume and the sorption efficiency of prepared monolithic in-needle extraction devices were determined experimentally. The achieved recovery was close to 90%, and determined LOQ values varied between 0.4 and 6 μg.

  15. Preparation and examination of monolithic in-needle extraction (MINE) device for the direct analysis of liquid samples

    International Nuclear Information System (INIS)

    Pietrzyńska, Monika; Voelkel, Adam; Bielicka-Daszkiewicz, Katarzyna

    2013-01-01

    Graphical abstract: -- Highlights: •MINE device for isolation of analytes from water samples. •Nine polymer poly(styrene-divinylbenzene) monoliths prepared in stainless steel needles. •High efficiency of in-needle extraction systems based on monolithic materials. •New possibilities in sample preparation area. -- Abstract: Combination of extraction and chromatographic techniques opens NEW possibilities in sample preparation area. Macroporous poly(styrene-divinylbenzene) (PS-DVB) monoliths were prepared by in situ polymerization in stainless steel needles. The surface of stainless steel needle was modified earlier by the silane coupling agent. Monolithic materials located inside needles were used as the in-needle extraction device. Scanning electron microscope (SEM) images were obtained for nine monoliths. Spectra of prepared materials were also performed with the use of two techniques: Attenuated Total Reflectance (ATR) and Fourier Transform Infrared Spectroscopy (FTIR). The new monolithic in-needle extraction (MINE) devices were used in the preparation of a series of test water samples for chromatographic analysis. The extraction of phenolic compounds from water samples was carried out by pumping liquid samples through the MINE device. Obtained results indicate a high efficiency of in-needle extraction systems based on monolithic materials. Breakthrough volume and the sorption efficiency of prepared monolithic in-needle extraction devices were determined experimentally. The achieved recovery was close to 90%, and determined LOQ values varied between 0.4 and 6 μg

  16. Migration of innumerable chronically retained acupuncture needles

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2017-09-01

    Full Text Available We present a case of a 50-year-old female with a 2-day history of back and abdominal pain who was discovered to have innumerable chronically retained acupuncture needles, which had migrated throughout her abdomen and pelvis. Although many of these needles were in precarious positions, including the epidural space, renal parenchyma, small bowel, and vasculature, there was no evidence for acute injury. We also briefly discuss evidence for the magnetic resonance imaging compatibility of acupuncture needles. Although a rare complication, given the high frequency of acupuncture therapy in the United States, physicians must be aware of the potential for retained and migrated needles.

  17. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  18. Experiences with a new breast localisation needle

    International Nuclear Information System (INIS)

    Hergan, K.; Amann, T.; Doringer, W.; Hollenstein, P.

    1990-01-01

    In view of the increasing number of biopsies of non-palpable lesions of the female breast we found an ideal localisation system in the Hawkins breast localisation needle. Localisation was successful without technical problems in 31 out of 34 patients. The special advantages of the needle are its stability in position and excellent manoeverability due to the construction of the needle. The very simple handling of the needle is an advantage not only for the radiologist but also for the surgeon. (orig.) [de

  19. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  20. The common structural architecture of Shigella flexneri and Salmonella typhimurium type three secretion needles.

    Directory of Open Access Journals (Sweden)

    Jean-Philippe Demers

    2013-03-01

    Full Text Available The Type Three Secretion System (T3SS, or injectisome, is a macromolecular infection machinery present in many pathogenic Gram-negative bacteria. It consists of a basal body, anchored in both bacterial membranes, and a hollow needle through which effector proteins are delivered into the target host cell. Two different architectures of the T3SS needle have been previously proposed. First, an atomic model of the Salmonella typhimurium needle was generated from solid-state NMR data. The needle subunit protein, PrgI, comprises a rigid-extended N-terminal segment and a helix-loop-helix motif with the N-terminus located on the outside face of the needle. Second, a model of the Shigella flexneri needle was generated from a high-resolution 7.7-Å cryo-electron microscopy density map. The subunit protein, MxiH, contains an N-terminal α-helix, a loop, another α-helix, a 14-residue-long β-hairpin (Q51-Q64 and a C-terminal α-helix, with the N-terminus facing inward to the lumen of the needle. In the current study, we carried out solid-state NMR measurements of wild-type Shigella flexneri needles polymerized in vitro and identified the following secondary structure elements for MxiH: a rigid-extended N-terminal segment (S2-T11, an α-helix (L12-A38, a loop (E39-P44 and a C-terminal α-helix (Q45-R83. Using immunogold labeling in vitro and in vivo on functional needles, we located the N-terminus of MxiH subunits on the exterior of the assembly, consistent with evolutionary sequence conservation patterns and mutagenesis data. We generated a homology model of Shigella flexneri needles compatible with both experimental data: the MxiH solid-state NMR chemical shifts and the state-of-the-art cryoEM density map. These results corroborate the solid-state NMR structure previously solved for Salmonella typhimurium PrgI needles and establish that Shigella flexneri and Salmonella typhimurium subunit proteins adopt a conserved structure and orientation in their

  1. How needless are Buffon's needles?

    International Nuclear Information System (INIS)

    Babović, Miloš; Babović, Vukota

    2013-01-01

    The study of statistical physics requires introductory preparation regarding probability theory. Understanding its fundamental concepts (randomness, distributions, fluctuations), and some experience in application of the basic concepts of statistics can be obtained in several ways. We found that the basic training in probability and statistics needed for physics and engineering study can be achieved by focusing on Buffon's needle problem. We believe this approach could help university specialists make study more efficient when probability and statistics play an important role. Buffon's experiment, with its convincing simplicity and flexibility, as well as its attractiveness, is in our opinion a useful tool in physics education at university level. (paper)

  2. Treatment of temporomandibular myofascial pain with deep dry needling

    Science.gov (United States)

    Gonzalez-Perez, Luis M.; Granados-Nuñez, Mercedes; Urresti-Lopez, Francisco J.

    2012-01-01

    Objectives: The present study was designed to evaluate the usefulness of deep dry needling in the treatment of temporomandibular myofascial pain. Study Design: We selected 36 patients with myofascial pain located in the external pterygoid muscle (30 women/6 men, mean age=27 years with SD±6,5). We studied differences in pain with a visual analog scale and range of mandibular movements before and after intervention. Results: We found a statistically significant relationship (p<0,01) between therapeutic intervention and the improvement of pain and jaw movements, which continued up to 6 months after treatment. Pain reduction was greater the higher was the intensity of pain at baseline. Conclusions: Although further studies are needed, our findings suggest that deep dry needling in the trigger point in the external pterygoid muscle can be effective in the management of patients with myofascial pain located in that muscle. Key words:Temporomandibular joint, myofascial pain, external pterygoid muscle, trigger point, deep dry needling. PMID:22549679

  3. Tipping the scales.

    Science.gov (United States)

    1998-12-01

    In the US, the October 1998 murder of a physician who performed abortions was an outward manifestation of the insidious battle against legal abortion being waged by radical Christian social conservatives seeking to transform the US democracy into a theocracy. This movement has been documented in a publication entitled, "Tipping the Scales: The Christian Right's Legal Crusade Against Choice" produced as a result of a 4-year investigation conducted by The Center for Reproductive Law and Policy. This publication describes how these fundamentalists have used sophisticated legal, lobbying, and communication strategies to further their goals of challenging the separation of church and state, opposing family planning and sexuality education that is not based solely on abstinence, promoting school prayer, and restricting homosexual rights. The movement has resulted in the introduction of more than 300 anti-abortion bills in states, 50 of which have passed in 23 states. Most Christian fundamentalist groups provide free legal representation to abortion clinic terrorists, and some groups solicit women to bring specious malpractice claims against providers. Sophisticated legal tactics are used by these groups to remove the taint of extremism and mask the danger posed to US constitutional principles being posed by "a well-financed and zealous brand of radical lawyers and their supporters."

  4. Evaluation of 8.0-cm needle at the fourth anterior axillary line for needle chest decompression of tension pneumothorax.

    Science.gov (United States)

    Chang, Samuel J; Ross, Samuel Wade; Kiefer, David J; Anderson, William E; Rogers, Amelia T; Sing, Ronald F; Callaway, David W

    2014-04-01

    Five-centimeter needles at the second intercostal space midclavicular line (2MCL) have high failure rates for decompression of tension pneumothorax. This study evaluates 8-cm needles directed at the fourth intercostal space anterior axillary line (4AAL). Retrospective radiographic analysis of 100 consecutive trauma patients 18 years or older from January to September 2011. Measurements of chest wall thickness (CWT) and depth to vital structure (DVS) were obtained at 2MCL and 4AAL. 4AAL measurements were taken based on two angles: closest vital structure and perpendicular to the chest wall. Primary outcome measures were radiographic decompression (RD) (defined as CWT RNI) (DVS > 80 mm) of 8-cm needles at 4AAL. Secondary outcome measures are effect of angle of entry on RNI at 4AAL, RD and RNI of 8-cm needles at 2MCL, and comparison of 5-cm needles with 8-cm needles at both locations. Eighty-four percent of the patients were male, with mean Injury Severity Score (ISS) of 17.7 (range, 1.0-66.0) and body mass index of 26.8 (16.5-48.4). Mean CWT at 4AAL ranged from 37.6 mm to 39.9 mm, significantly thinner than mean CWT at 2MCL (43.3-46.7 mm). Eight-centimeter needle RD was more than 96% at both 4AAL and 2MCL. Five-centimeter RD ranged from 66% to 81% at all sites. Mean DVS at 4AAL ranged from 91.8 mm to 128.0 mm. RNI at all sites was more than 91% except at left 4AAL, when taken to the closest vital structure (mean DVS, 91.8 mm), with 68% RNI. Perpendicular entry increased DVS to 109.4 mm and subsequent RNI to 91%. Five-centimeter RNI at all sites was more than 99%. CWT at 4AAL is significantly thinner than 2MCL. Based on radiographic measurements, 8-cm catheters have a higher chance of pleural decompression when compared with 5-cm catheters. Steeper angle of entry at 4AAL improves 8-cm noninjury rates to more than 91%. Therapeutic/care management study, level IV.

  5. Torsional Phacoemulsification and Tip Selection

    Directory of Open Access Journals (Sweden)

    Fırat Helvacıoğlu

    2014-10-01

    Full Text Available One of the recent advances in cataract surgery is torsional phacoemulsification. It was developed to increase the efficacy of ultrasonic emulsification. In torsional phacoemulsification, the torsional movement of the tip is translated to side-to-side cutting action with the aid of bent phaco tips. Lens material is cut in both directions, rather than only during a forward stroke. The efficiency of this technique is further enhanced by an improvement in followability provided by the inherent non-repulsive nature of the side-to-side motion. Tip selection is very important for the efficiency of torsional phacoemulsification. Theoretically, there are 2 ways to enhance the cutting efficiency of the tip. First is the stroke length; the 22-degree bent 30-degree Kelman mini-flared tip cuts longer than the 12-degree bent 30-degree mini-flared Kelman tip. Second is the angulation or bevel; the higher the degree (45 degrees, the better cutting efficiency. Retrospective analyses of the previously published clinical studies clearly demonstrated that the efficacy of the torsional phacoemulsification has positive correlation with both the aperture angles and neck angles of the tips. (Turk J Ophthalmol 2014; 44: 392-5

  6. Diagnosis of mediastinal neoplasms using mediastinoscopy and CT-guided needle biopsy supported by gene analysis

    International Nuclear Information System (INIS)

    Chiba, Wataru; Sawai, Satoru; Ishida, Hisao; Hanawa, Takeshi; Matsubara, Yoshito; Ikeda, Sadao; Kinoshita, Moritoshi; Ikei, Nobuhiro.

    1993-01-01

    Of 140 cases of mediastinal neoplasms in our hospital, histological diagnosis was confirmed in 129 cases. We examined the methods of preoperative biopsy with those 129 cases. Biopsy had been performed in 25 cases. Mediastinoscopy was performed in seven cases, needle biopsy in eight cases, lymph node biopsy in eight cases, esophageal biopsy using a gastrofiberscope in one case, transbronchial biopsy using a bronchoscope in one case. The true positive rates of those methods were 100% for both mediastinoscopy and lymph node biopsy, and 75% for needle biopsy. Preoperative misdiagnosis occurred in two cases of needle biopsy. The postoperative histological diagnosis was malignant lymphoma in both cases. We performed gene analysis of the immunoglobulin heavy chain gene, light chain κ and λ genes, and the T-cell receptor β gene by use of biopsied specimens, and we found rearrangement bands of these genes in the cases of malignant lymphoma. Therefore, we summarize that gene analysis is a reliable method if malignant lymphoma is suspected. If a needle biopsy is performed under CT guidance, the needle is sure to puncture the tumor. We concluded, therefore, that if a tumor is located in the anterior mediastinum, CT-guided needle biopsy should be performed first of all. Mediastinoscopy is a useful method if the tumor is located in the mid-mediastinum. (author)

  7. Uranium solubility and solubility controls in selected Needle's Eye groundwaters

    International Nuclear Information System (INIS)

    Falck, W.E.; Hooker, P.J.

    1992-01-01

    The British Geological Survey (BGS) has been co-ordinating a research programme centred on the Needle's Eye natural analogue site in Dumfries and Galloway District, southwest Scotland. This study of a natural radioactive geochemical system has been carried out with the aim of improving confidence in using geochemical and predictive models of radionuclide (uranium) migration in the geosphere. The Needle's Eye site is located on the Solway Coat within the Southwick Coast Reserve of the Scottish Wildlife Trust who gave permission to sample for soils, sediments and waters for analysis. This report is one of a series and covers the period from June 1989 to June 1990. It presents the results of applying the PHREEQE code to the hydrochemistry of the site using the CHEMVAL thermodynamic database. (author)

  8. Investigation of UWB Wind Turbine Blade Deflection Sensing with a Tip Antenna inside a Blade

    DEFF Research Database (Denmark)

    Zhang, Shuai; Jensen, Tobias Lindstrøm; Franek, Ondrej

    2016-01-01

    An UWB blade deflection sensing system with a tip antenna inside a blade is investigated in this paper. The lower UWB band of 3.1-5.3 GHz is utilized. This system composes of two UWB radio links between one antenna inside the blade tip and two antennas outside the blade root. Blade deflections...... are tracked via two radio links using delay-based distance estimation and triangulation. In order to build reliable radio links, time-domain pulse field distributions are simulated to optimize the in-blade tip antenna polarization and the locations of the two root antennas around the root surface. Full......-blade time-domain measurements are proposed to verify the simulations and realize the blade deflection sensing with an in-blade tip antenna. With the optimized in-blade tip antenna polarization and two root antenna locations, an accuracy of 2 cm is achieved for the tip-root antenna distance estimation...

  9. Combined frequency modulated atomic force microscopy and scanning tunneling microscopy detection for multi-tip scanning probe microscopy applications

    International Nuclear Information System (INIS)

    Morawski, Ireneusz; Spiegelberg, Richard; Korte, Stefan; Voigtländer, Bert

    2015-01-01

    A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. The high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations

  10. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  11. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Directory of Open Access Journals (Sweden)

    Bertrand Y. K. Loyeung

    2013-01-01

    Full Text Available Introduction. In traditional Chinese acupuncture, needle sensation (deqi is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site.

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Transjugular Intrahepatic Portosystemic Shunt (TIPS) Transjugular ... in the portal vein system. This pressure buildup can cause blood to flow backward from the liver ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... physician will numb an area just above your right collarbone with a local anesthetic . A very small ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in the chest or abdomen. This condition is most commonly seen in adults, often as a result ... minimally invasive procedures such as a TIPS are most often performed by a specially trained interventional radiologist ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and lengthy procedures requiring extended fluoroscopy use) death (rare) top of page What are the limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening liver failure ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... less likely to require a TIPS. top of page What are some common uses of the procedure? A ... gown to wear during the procedure. top of page What does the equipment look like? In this procedure, ...

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the hepatic vein in the liver. A small metal device called a stent is placed to keep ... open by the placement of a small, tubular metal device commonly called a stent . During a TIPS ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... of bleeding that can occur can sometimes be life threatening and those patients are monitored in intensive ... invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients ... site. Using ultrasound, the doctor will identify your internal jugular vein , which is situated above your collarbone, ...

  1. Choking and Strangulation Prevention Tips

    Science.gov (United States)

    ... Safety Sponsors Recalls Media Center Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Search Menu Why It Matters ... Safety Sponsors Recalls Media Center Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Sign up for quick tips ...

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... hepatic vein to identify the portal venous system. Access is then gained from the hepatic vein into ... TIPS procedure to make sure that it remains open and functions properly. top of page Who interprets ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ... American College of Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients with cirrhosis. Tell your ... the liver into the veins of the spleen, stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in an hour or two but may take up to several hours depending on the complexity of ... normal activities in seven to 10 days. Follow-up ultrasounds will be performed frequently after the TIPS ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... portal vein to the hepatic vein in the liver. A small metal device called a stent is ... bowel back to the heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... of an effect than open surgical bypass on future liver transplantation surgery because the abdomen has not ... TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... blood draining from the bowel back to the heart while avoiding the liver. TIPS may successfully reduce ... blood away from the liver back to the heart). A stent is then placed in this tunnel ...

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. You ... with ascites or variceal bleeding resistant to traditional medical treatments. The greatest difference in performing TIPS in ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose ...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  12. Search Tips: MedlinePlus

    Science.gov (United States)

    ... of this page: https://medlineplus.gov/searchtips.html Search Tips To use the sharing features on this page, please enable JavaScript. How do I search MedlinePlus? The search box appears at the top ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... to the heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and ... conditions, allergies and medications you’re taking. You may be advised to stop taking aspirin, nonsteroidal anti- ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... risks. Other possible complications of the procedure include: fever muscle stiffness in the neck bruising on the ... filtered out by the liver. The TIPS may cause too much of these substances to bypass the ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients with ... stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding and the accumulation of fluid in the chest ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... system. This pressure buildup can cause blood to flow backward from the liver into the veins of ... does the procedure work? A TIPS reroutes blood flow in the liver and reduces abnormally high blood ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... liver back to the heart. top of page How should I prepare? You should report to your ... heart beat and blood pressure. top of page How does the procedure work? A TIPS reroutes blood ...

  18. Computerized automatic tip scanning operation

    International Nuclear Information System (INIS)

    Nishikawa, K.; Fukushima, T.; Nakai, H.; Yanagisawa, A.

    1984-01-01

    In BWR nuclear power stations the Traversing Incore Probe (TIP) system is one of the most important components in reactor monitoring and control. In previous TIP systems, however, operators have suffered from the complexity of operation and long operation time required. The system presented in this paper realizes the automatic operation of the TIP system by monitoring and driving it with a process computer. This system significantly reduces the burden on customer operators and improves plant efficiency by simplifying the operating procedure, augmenting the accuracy of the measured data, and shortening operating time. The process computer is one of the PODIA (Plant Operation by Displayed Information Automation) systems. This computer transfers control signals to the TIP control panel, which in turn drives equipment by microprocessor control. The process computer contains such components as the CRT/KB unit, the printer plotter, the hard copier, and the message typers required for efficient man-machine communications. Its operation and interface properties are described

  19. Tips to Prevent Tick Bites

    Science.gov (United States)

    Using the right insect repellent and other preventive actions can discourage ticks, mosquitoes, and other biting insects from landing on you. Tips include avoiding tick habitats and minimizing exposed skin.

  20. Tips to Prevent Mosquito Bites

    Science.gov (United States)

    Using the right insect repellent and other preventive actions can discourage mosquitoes from landing on you. Tips include removing mosquito habitats such as standing water, minimizing exposed skin, and staying indoors while mosquitoes are most active.

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Patients who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal ... leading to cirrhosis (scarring of the liver). Portal hypertension can also occur in children, although children are ...

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A TIPS is used to treat the ... during the procedure. top of page What does the equipment look like? In this procedure, x-ray ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... is completed. top of page What are the benefits vs. risks? Benefits A TIPS is designed to produce the same ... urgent intervention heart arrhythmias or congestive heart failure radiation injury to the skin is a rare complication ( ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... local anesthetic medications, general anesthesia or to contrast materials containing iodine (sometimes referred to as "dye" or " ... the placement of the TIPS stent, a contrast material will be injected in the hepatic vein to ...

  6. KINEMATICS FRICTION PAIR FOR EXAMPLE NEEDLE BEARINGS

    Directory of Open Access Journals (Sweden)

    Jerzy NACHIMOWICZ

    2014-06-01

    Full Text Available The present study concerns certain phenomena that take place in the needle roller bearing. The friction that generates the anti-torque of a friction pair is the major factor that influences the needle bearing’s wear. In the needle bearing there occur two predominant types of friction: the rolling friction and the sliding friction, and both are subject to examination. The study presents recordings and analysis of the movements of all needle bearing’s rolling elements. The examination was carried out on a special examination stand that precisely emulates the real conditions of the needle bearing’s work. Carefully prepared examination methods enable recording and analyzing frictions in the bearing, estimating a sphere within which the load is shifted, and calculating the coefficient of friction.

  7. Tip model of cold fission

    International Nuclear Information System (INIS)

    Goennenwein, F.; Boersig, B.

    1991-01-01

    Cold fission is defined to be the limiting case of nuclear fission where virtually all of the available energy is converted into the total kinetic energy of the fragments. The fragments have, therefore, to be born in or at least close to their respective ground states. Starting from the viewpoint that cold fission corresponds to most compact scission configurations, energy constraints have been exploited to calculate minimum tip distances between the two nascent fragments in binary fission. Crucial input parameters to this tip model of cold fission are the ground-state deformations of fragment nuclei. It is shown that the minimum tip distances being compatible with energy conservation vary strongly with both the mass and charge fragmentation of the fission prone nucleus. The tip distances refer to nuclei with equivalent sharp surfaces. In keeping with the size of the surface width of leptodermous nuclei, only configurations where the tip distances are smaller than a few fm may be considered as valid scission configurations. From a comparison with experimental data on cold fission this critical tip distance appears to be 3.0 fm for the model parameters chosen. Whenever the model calculation yields tip distances being smaller than the critical value, a necessary condition for attaining cold fission is considered to be fulfilled. It is shown that this criterion allows to understand in fair agreement with experiment which mass fragmentations are susceptible to lead to cold fission and which fragment-charge divisions are the most favored in each isobaric mass chain. Being based merely on energy arguments, the model cannot aim at predicting fragment yields in cold fission. However, the tip model proposed appears well suited to delineate the phase space where cold fission phenomena may come into sight. (orig.)

  8. Modeling, simulation, and optimal initiation planning for needle insertion into the liver.

    Science.gov (United States)

    Sharifi Sedeh, R; Ahmadian, M T; Janabi-Sharifi, F

    2010-04-01

    Needle insertion simulation and planning systems (SPSs) will play an important role in diminishing inappropriate insertions into soft tissues and resultant complications. Difficulties in SPS development are due in large part to the computational requirements of the extensive calculations in finite element (FE) models of tissue. For clinical feasibility, the computational speed of SPSs must be improved. At the same time, a realistic model of tissue properties that reflects large and velocity-dependent deformations must be employed. The purpose of this study is to address the aforementioned difficulties by presenting a cost-effective SPS platform for needle insertions into the liver. The study was constrained to planar (2D) cases, but can be extended to 3D insertions. To accommodate large and velocity-dependent deformations, a hyperviscoelastic model was devised to produce an FE model of liver tissue. Material constants were identified by a genetic algorithm applied to the experimental results of unconfined compressions of bovine liver. The approach for SPS involves B-spline interpolations of sample data generated from the FE model of liver. Two interpolation-based models are introduced to approximate puncture times and to approximate the coordinates of FE model nodes interacting with the needle tip as a function of the needle initiation pose; the latter was also a function of postpuncture time. A real-time simulation framework is provided, and its computational benefit is highlighted by comparing its performance with the FE method. A planning algorithm for optimal needle initiation was designed, and its effectiveness was evaluated by analyzing its accuracy in reaching a random set of targets at different resolutions of sampled data using the FE model. The proposed simulation framework can easily surpass haptic rates (>500 Hz), even with a high pose resolution level ( approximately 30). The computational time required to update the coordinates of the node at the

  9. Efficient Transdermal Delivery of Alendronate, a Nitrogen-Containing Bisphosphonate, Using Tip-Loaded Self-Dissolving Microneedle Arrays for the Treatment of Osteoporosis.

    Science.gov (United States)

    Katsumi, Hidemasa; Tanaka, Yutaro; Hitomi, Kaori; Liu, Shu; Quan, Ying-Shu; Kamiyama, Fumio; Sakane, Toshiyasu; Yamamoto, Akira

    2017-08-17

    To improve the transdermal bioavailability and safety of alendronate (ALN), a nitrogen-containing bisphosphonate, we developed self-dissolving microneedle arrays (MNs), in which ALN is loaded only at the tip portion of micron-scale needles by a dip-coating method (ALN(TIP)-MN). We observed micron-scale pores in rat skin just after application of ALN(TIP)-MN, indicating that transdermal pathways for ALN were created by MN. ALN was rapidly released from the tip of MNs as observed in an in vitro release study. The tip portions of MNs completely dissolved in the rat skin within 5 min after application in vivo. After application of ALN(TIP)-MN in mice, the plasma concentration of ALN rapidly increased, and the bioavailability of ALN was approximately 96%. In addition, the decrease in growth plate was effectively suppressed by this efficient delivery of ALN in a rat model of osteoporosis. Furthermore, no skin irritation was observed after application of ALN(TIP)-MN and subcutaneous injection of ALN, while mild skin irritation was induced by whole-ALN-loaded MN (ALN-MN)-in which ALN is contained in the whole of the micron-scale needles fabricated from hyaluronic acid-and intradermal injection of ALN. These findings indicate that ALN(TIP)-MN is a promising transdermal formulation for the treatment of osteoporosis without skin irritation.

  10. Ball tip method for thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis

    International Nuclear Information System (INIS)

    Watanabe, Kota; Matsumoto, Morio; Iizuka, Shingo

    2008-01-01

    The purpose of this study was to evaluate the efficacy of ball tip method for thoracic pedicle screw placements in idiopathic scoliosis patients. 24 patients with adolescent idiopathic scoliosis were included in this study. Conventional method was performed in 12 patients. Ball tip method was performed in 12 patients. Accuracy of the pedicle screw placement was evaluated based on the postoperative CT. In the ball tip method, a probe which was consisted of ball tip with flexible shaft was used. After removing of cortical bone at a starting point, the probe was inserted manually or sometimes with gently tapping by hammer. During the maneuver, the probe will gradually progress into cancellous bone in the pedicle, without perforating cortical bone in the pedicle. Following expansion of the hole by a rigid gear shift probe, screw was placed in the pedicle. 65.1% of screws were located within pedicle in the conventional group and 86.5% in the ball tip group. 5.3% of screws were located out of pedicle within 2 mm in the conventional group and 8.2% in the ball tip group. 15.8% of screws were located out of pedicle beyond 2 mm and 1.8% in the ball tip group. The ball tip method enhanced the accuracy of thoracic pedicle screw placements in adolescent idiopathic scoliosis patients. The ball tip method may be effective for accurate pedicle screw placement in patients with adolescent idiopathic scoliosis. (author)

  11. Noncontact Viscoelastic Imaging of Living Cells Using a Long-Needle Atomic Force Microscope with Dual-Frequency Modulation

    Science.gov (United States)

    Guan, Dongshi; Charlaix, Elisabeth; Qi, Robert Z.; Tong, Penger

    2017-10-01

    Imaging of surface topography and elasticity of living cells can provide insight into the roles played by the cells' volumetric and mechanical properties and their response to external forces in regulating the essential cellular events and functions. Here, we report a unique technique of noncontact viscoelastic imaging of live cells using atomic force microscopy (AFM) with a long-needle glass probe. Because only the probe tip is placed in a liquid medium near the cell surface, the AFM cantilever in air functions well under dual-frequency modulation, retaining its high-quality resonant modes. The probe tip interacts with the cell surface through a minute hydrodynamic flow in the nanometer-thin gap region between them without physical contact. Quantitative measurements of the cell height, volume, and Young's modulus are conducted simultaneously. The experiment demonstrates that the long-needle AFM has a wide range of applications in the study of cell mechanics.

  12. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions gauges (P > .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Effects of Different Rotary Files Combined with Different Irrigation Needles on Apically Extruded Debris.

    Science.gov (United States)

    Uzunoglu, Emel; Turker, Sevinc Aktemur; Görduysus, Melahat

    2015-01-01

    The aim of this study was to compare the apically extruded debris associated with ProTaper Next and OneShape Apical files using two different irrigation needles, open-ended and closed-ended (Max-I-Probe). Forty-eight mandibular premolars were assigned to four groups (n=12) as follows: Group PTN-SN: Root canal was prepared with ProTaper Next (PTN) and irrigated with open-ended standard needle; Group PTN-MP: Root canal was prepared with PTN and irrigated with Max-I-Probe; Group OSA-SN: Root canal was prepared with OneShape Apical (OSA) and irrigated with open-ended needle; Group OSA-MP: Root canal was prepared with OSA and irrigated with Max-I-Probe. Debris extruded during instrumentation was collected into pre-weighed Eppendorf tubes. After storage in an incubator at 70 °C for 5 days, the Eppendorf tubes were weighed to obtain the final weight with extruded debris. The difference between pre-and post-debris weights was calculated and statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests (pextruded debris (p>0.05). OneShape Apical and ProTaper Next resulted in extrusion of debris beyond the apical foramen, regardless of needle tip.

  14. Preparation of Graphene-Modified Acupuncture Needle and Its Application in Detecting Neurotransmitters

    Science.gov (United States)

    Tang, Lina; Du, Danxin; Yang, Fan; Liang, Zhong; Ning, Yong; Wang, Hua; Zhang, Guo-Jun

    2015-06-01

    We report a unique nanosensing platform by combining modern nanotechnology with traditional acupuncture needle to prepare graphene-modified acupuncture needle (G-AN), and using it for sensitive detection of neurotransmitters via electrochemistry. An electrochemical deposition method was employed to deposit Au nanoparticles (AuNPs) on the tip surface of the traditional acupuncture needle, while the other part of the needle was coated with insulation paste. Subsequently, the G-AN was obtained by cyclic voltammetry reduction of a graphene oxide solution on the surface of the AuNPs. To investigate the sensing property of the G-AN, pH dependence was measured by recording the open circuit potential in the various pH buffer solutions ranging from 2.0 to 10.0. What’s more, the G-AN was further used for detection of dopamine (DA) with a limit of detection of 0.24 μM. This novel G-AN exhibited a good sensitivity and selectivity, and could realize direct detection of DA in human serum.

  15. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  16. Location, location, location: Extracting location value from house prices

    OpenAIRE

    Kolbe, Jens; Schulz, Rainer; Wersing, Martin; Werwatz, Axel

    2013-01-01

    The price for a single-family house depends both on the characteristics of the building and on its location. We propose a novel semiparametric method to extract location values from house prices. After splitting house prices into building and land components, location values are estimated with adaptive weight smoothing. The adaptive estimator requires neither strong smoothness assumptions nor local symmetry. We apply the method to house transactions from Berlin, Germany. The estimated surface...

  17. The Biological Safety of Stainless Steel Needles Used in Warm-Needling

    Directory of Open Access Journals (Sweden)

    Sabina Lim

    2010-01-01

    Full Text Available Warm-needling (also called thermo-acupuncture is a combination of acupuncture and moxibustion. Due to the intense heat involved, there have been concerns over the biological safety of the acuneedles used in the treatment. This paper reports two phases of a safety test. For a preliminary test, we compared the temperature change patterns of stainless steel (SS304 needles and traditional gold alloy needles, which have been increasingly replaced by the former. To verify the effects of the presence of coating materials, the main test involved three different kinds of SS304: silicone-coated, salicylic acid-coated and non-coated needles. Each group of needles was tested for pH level, heavy metals and UV absorbance spectrum along with biological tests on the cytotoxicity and hemolysis of the needle. All the tests on the extractants from the needles were negative. In the biological tests, each test result showed a significant difference from the positive control samples, while no significant difference was observed compared with the negative control samples. In the hemolysis tests, all samples satisfied the Korean Government Standards. All the results suggest that SS304 needles are biologically safe to be used in warm-needling, though they can be improved to perform as well as the gold alloy needles in terms of temperature fluctuations.

  18. New radiofrequency device to reduce bleeding after core needle biopsy: Experimental study in a porcine liver model

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Hyeok; Rhim, Hyun Chul; Lee, Min Woo; Song, Kyoung Doo; Kang, Tae Wook; Kim, Young Sun; Lim, Hyo Keun [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-01-15

    To evaluate the in vivo efficiency of the biopsy tract radiofrequency ablation for hemostasis after core biopsy of the liver in a porcine liver model, including situations with bleeding tendency and a larger (16-gauge) core needle. A preliminary study was performed using one pig to determine optimal ablation parameters. For the main experiment, four pigs were assigned to different groups according to heparinization use and biopsy needle caliber. In each pig, 14 control (without tract ablation) and 14 experimental (tract ablation) ultrasound-guided core biopsies were performed using either an 18- or 16-gauge needle. Post-biopsy bleeding amounts were measured by soaking up the blood for five minutes. The results were compared using the Mann-Whitney U test. The optimal parameters for biopsy tract ablation were determined as a 2-cm active tip electrode set at 40-watt with a tip temperature of 70–80℃. The bleeding amounts in all experimental groups were smaller than those in the controls; however they were significant in the non-heparinized pig biopsied with an 18-gauge needle and in two heparinized pigs (p < 0.001). In the heparinized pigs, the mean blood loss in the experimental group was 3.5% and 13.5% of the controls biopsied with an 18- and 16-gauge needle, respectively. Radiofrequency ablation of hepatic core biopsy tract ablation may reduce post-biopsy bleeding even under bleeding tendency and using a larger core needle, according to the result from in vivo porcine model experiments.

  19. Complications of transradial coronary angiography: a comparative study between using trocar needle and using bare needle

    International Nuclear Information System (INIS)

    Huang Chunyan; Wang Zhongjie; Chen Liyuan

    2010-01-01

    Objective: To analyze the advantages and disadvantages of trocar needle puncturing and bare needle puncturing in performing transradial coronary angiography through comparing the surgical successful rate and the occurrence of complications between two techniques. Methods: A total of 450 patients, who were scheduled to receive transradial coronary angiography, were enrolled in this study. The patients were randomly and equally divided into trocar needle group (n=225) and bare needle group (n=225). Transradial coronary angiography was performed in all patients, the technical success and the puncture-related complications were observed. The differences between two groups were compared and the results were statistically analyzed. Results: The successful rate of placing sheath pipe in trocar needle group and bare needle group was 98.22% (221/225) and 90.22% (203/225) respectively, the difference between two groups was statistically significant (P < 0.01). The mean time spent in puncturing in trocar needle group and bare needle group was (3.98 ± 0.54) min. and (6.13 ± 0.61) min. respectively (P < 0.01). In bare needle group the complications included radial artery spasm (4.89%, n=11), subcutaneous ecchymosis (6.67%, n=15) and local hematoma (3.56%, n=8), while in trocar group the complications included radial artery spasm (1.33%, n=3), subcutaneous ecchymosis (2.67%, n=6) and local hematoma (0.44%, n=1). Conclusion: In performing percutaneous coronary arteriography via radial arterial access the use of trocar needle is superior to the use of bare needle. Using trocar needle can reduce the operative time,increase the technical successful rate and lower the occurrence of complications. Therefore, using trocar needle to perform puncturing should be the technique of first choice. (authors)

  20. Experimental Study of the Effects of Blade Treatments on the Tip Vortex Characteristics.

    Science.gov (United States)

    Klimchenko, Vera

    2015-11-01

    The current study investigates the effects of blade tip treatments on the characteristics of a wind turbine blade tip vortex. Three blade tip shapes including a blunt edge, leading edge comb, and a winglet were designed and tested in a low speed wind tunnel. The rotor with a blunt edge was considered to be a baseline case corresponding to an untreated blade tip. The leading-edge comb rotor was designed with leading edge tubercles extending from the tip of the blade inward, 6 percent of rotor diameter. The winglet located at the tip of the winglet rotor had a cant angle of 45 degrees. The wind turbine operated at a tip speed ratio of 5 and a tip Reynolds number of 14,000. The tip treatments were intended to weaken the tip vortices by encouraging dissipation (leading edge comb) or promoting the formation of weaker vortices (winglet). Time-resolved and phase-averaged PIV was used to measure the velocity field behind the rotor. The time-averaged velocity field was subtracted from the phase-averaged velocity field to isolate the time-varying components of the flow. The vorticity of the phase-averaged time-varying field was calculated, and the tip vortices were identified using a vortex identification method. Vortex characteristics such as core radius and vortex strength were calculated and compared for the three rotors. The analysis of the vorticity showed that the winglet rotor had weaker tip vortices with a larger core radius, while the serrated tip rotor had strong tip vortices with the same core radius as the baseline case.

  1. Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking.

    Science.gov (United States)

    Kim, Jun Sik; Park, Young Ji; Lee, Yoon Jung; Kim, Nam Gyun; Lee, Kyung Suk

    2016-12-01

    Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.

  2. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  3. [Comparison of analgesic effects between subcutaneous penetration needling and straight needling of otopoints in the treatment of scapulohumeral periarthritis].

    Science.gov (United States)

    Jia, Chun-Sheng; Li, Xiao-Feng; Ma, Xiao-Shun; Shi, Jing; Liu, Er-Jun

    2008-10-01

    To confirm the better analgesic effect of subcutaneous penetration needling of otopoints for treatment of scapulohumeral periarthritis (SHPA) patients. Sixty-six SHPA patients were randomized into penetration-needling group (n = 33) and straight needling group (n = 33) by using pairing principle according to the sex and state of disease. Penetration needling was adopted for patients of penetration-needling group, while straight needling was used for those of straight needling group. Simplified McGill Scale was used to evaluate the patients' pain reactions. The pain integral scores were analyzed by using sequential test and pairing t test. Sequential test showed that the analgesic effect of penetration needling was significantly superior to that of straight needling 30 min after the treatment (P straight needling (P straight needling in the treatment of scapulohumeral periarthritis.

  4. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Science.gov (United States)

    Chesnel, Camille; Genêt, François; Almangour, Waleed; Denormandie, Philippe; Parratte, Bernard; Schnitzler, Alexis

    2015-01-01

    Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning) is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia. To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers. Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons) carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred. Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%): 4 (1%) in tendons or muscles, 3 (0.7%) in nerves and 1 (0.2%) in a vessel. This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  5. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  6. [Design thinking and clinical basic operation rules of the needling instrument for Shu-needle therapy].

    Science.gov (United States)

    Bao, Shou-qian

    2009-03-01

    Shu-needle therapy is a transcutaneous, close and micro-traumatic treatment technique founded on the basis of the theoretical system and the treatment thought of TCM acupuncture eye surgery. This therapy uses the needling instrument for Shu-needle therapy of original creation to relieve pressure, relieve tension, relieve spasm, relieve rigid, etc. for chronic pain, and achieves unique clinical therapeutic effects, and it originally creates the diagnostic and therapeutic system of special acupoint selection for human chronic pain and difficult diseases of the vegetable nerves and important treatment rules, in combination with modern medicine. Shu-needle therapy mixes TCM surgery with the cream of other special acupuncture therapies, and it is a new development and supplement of special needling therapies such as small needle knife, etc. and traditional acupuncture treatment.

  7. Metastatic Chordoma: A Diagnostic Challenge on Fine Needle Aspiration

    Directory of Open Access Journals (Sweden)

    Ghassan Tranesh

    2016-01-01

    Full Text Available Chordomas are primary low grade malignant tumors of bone that usually arise within both ends of axial skeleton. The Notochord is a midline, ectoderm-derived structure that defines the phylum of chordates. Chordomas may pose difficult diagnostic challenges when encountered in secondary locations, such as lungs or other parenchymatous organs. We report the cytologic findings of a metastatic chordoma sampled through CT-scan guided fine needle aspiration (FNA of lower lobe lung nodule in a 54-year-old man diagnosed with recurrent chordoma involving the lumber spine and paraspinal region.

  8. SU-F-P-59: Detection of Missing Surgical Needles with Intraoperative Mobile X-Ray

    Energy Technology Data Exchange (ETDEWEB)

    Chen, L [William Beaumont Hospital, Troy, Troy, MI (United States); Berger, B

    2016-06-15

    Purpose: To determine the minimal detectable size of a surgical needle using intraoperative mobile x-ray imaging. Also, varying techniques such as low kVp and high tube current were tested to investigate whether this improved the detection of the various needle sizes. Methods: Seven surgical needle sizes, 6.5, 8, 11, 13, 16, 17 and 19 mm, were positioned on three regions (thoracic, abdominal and pelvic) of an adult size anthropomorphic RANDO phantom. The phantom represents an average size adult. The phantom, in front of detector, was imaged with 44” x-ray tube to detector distance. For the thoracic region, each needle size was imaged 4 times using the following technique (81 kVp at 32 mAs and 200 mAs; then 100 kVp at 32 mAs and 200 mAs. This was repeated for the abdominal and pelvic regions of the phantom. The images were reviewed by a board certified diagnostic radiologist. Results: The surgical needles sized 13 mm and above were visible at all three body regions using all four kVp and mAs combinations. For surgical needle sizes 8 and 11 mm, the visibility of needle was ambiguous in thoracic region and barely visible abdominal and pelvic regions. Surgical needles, with size smaller than 8 mm, could not be visualized on x-ray with unassisted eyesight. The detectability of the smaller sized needles was not improved with increasing mAs or decreasing kVp. Conclusion: Surgical needle sizes less that 13 mm were not visualized with intraoperative mobile x-ray imaging using various mAs and kVp combinations. Intraoperative mobile x-ray is not recommended to locate surgical needle sizes less than 13 mm for the following reasons: (1) it prevents unnecessary radiation exposure to patient, (2) it avoids the delay time with wound closure and completion of the operative procedure, and (3) it saves radiologist reading time.

  9. Nanobits: customizable scanning probe tips

    DEFF Research Database (Denmark)

    Kumar, Rajendra; Shaik, Hassan Uddin; Sardan Sukas, Özlem

    2009-01-01

    We present here a proof-of-principle study of scanning probe tips defined by planar nanolithography and integrated with AFM probes using nanomanipulation. The so-called 'nanobits' are 2-4 mu m long and 120-150 nm thin flakes of Si3N4 or SiO2, fabricated by electron beam lithography and standard...... or dislocation of the tips of the nanobit after several scans. This approach allows an unprecedented freedom in adapting the shape and size of scanning probe tips to the surface topology or to the specific application....... silicon processing. Using a microgripper they were detached from an array and fixed to a standard pyramidal AFM probe or alternatively inserted into a tipless cantilever equipped with a narrow slit. The nanobit-enhanced probes were used for imaging of deep trenches, without visible deformation, wear...

  10. Analytic theory for the selection of 2-D needle crystal at arbitrary Peclet number

    Science.gov (United States)

    Tanveer, Saleh

    1989-01-01

    An accurate analytic theory is presented for the velocity selection of a two-dimensional needle crystal for arbitrary Peclet number for small values of the surface tension parameter. The velocity selection is caused by the effect of transcendentally small terms which are determined by analytic continuation to the complex plane and analysis of nonlinear equations. The work supports the general conclusion of previous small Peclet number analytical results of other investigators, though there are some discrepancies in details. It also addresses questions raised on the validity of selection theory owing to assumptions made on shape corrections at large distances from the tip.

  11. Analytic theory for the selection of a two-dimensional needle crystal at arbitrary Peclet number

    Science.gov (United States)

    Tanveer, S.

    1989-01-01

    An accurate analytic theory is presented for the velocity selection of a two-dimensional needle crystal for arbitrary Peclet number for small values of the surface tension parameter. The velocity selection is caused by the effect of transcendentally small terms which are determined by analytic continuation to the complex plane and analysis of nonlinear equations. The work supports the general conclusion of previous small Peclet number analytical results of other investigators, though there are some discrepancies in details. It also addresses questions raised on the validity of selection theory owing to assumptions made on shape corrections at large distances from the tip.

  12. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  13. Pine needle abortion biomarker detected in bovine fetal fluids

    Science.gov (United States)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  14. Multimode fibre: Light-sheet microscopy at the tip of a needle.

    Science.gov (United States)

    Plöschner, Martin; Kollárová, Věra; Dostál, Zbyněk; Nylk, Jonathan; Barton-Owen, Thomas; Ferrier, David E K; Chmelík, Radim; Dholakia, Kishan; Čižmár, Tomáš

    2015-12-14

    Light-sheet fluorescence microscopy has emerged as a powerful platform for 3-D volumetric imaging in the life sciences. Here, we introduce an important step towards its use deep inside biological tissue. Our new technique, based on digital holography, enables delivery of the light-sheet through a multimode optical fibre--an optical element with extremely small footprint, yet permitting complex control of light transport processes within. We show that this approach supports some of the most advanced methods in light-sheet microscopy: by taking advantage of the cylindrical symmetry of the fibre, we facilitate the wavefront engineering methods for generation of both Bessel and structured Bessel beam plane illumination. Finally, we assess the quality of imaging on a sample of fluorescent beads fixed in agarose gel and we conclude with a proof-of-principle imaging of a biological sample, namely the regenerating operculum prongs of Spirobranchus lamarcki.

  15. ZBrush Professional Tips and Techniques

    CERN Document Server

    Gaboury, Paul

    2012-01-01

    Learn to work effectively and creatively with all versions of ZBrush! ZBrush is used by top artists in Hollywood to model and sculpt characters in such films as Avatar, Iron Man, and Pirates of the Caribbean. In addition, this amazing technology is also used in jewelry design, forensic science, aerospace, video games, toy creation, and the medical field. Written by Pixologic's in-house ZBrush expert Paul Gaboury, this full-color, beautifully illustrated guide provides you with the ultimate tips and tricks to maximize your use of all versions of ZBrush. Reveals numerous little-known tips and tr

  16. Office 2010 Visual Quick Tips

    CERN Document Server

    Gunter, Sherry Kinkoph

    2010-01-01

    Get more done in Office 2010 in less time with these Quick Tips!. Whether you're new to Microsoft Office or updating from older versions, this is the perfect resource to get you quickly up to speed on Office 2010. Every application is covered, including Word, Excel, PowerPoint, Outlook, and Publisher. Full-color screenshots and numbered steps clearly explain dozens of features and functions-while quick shortcuts, tips, and tricks help you save time and boost productivity. You'll also find great new ways to access and use some Office apps right from the Web.: Walks you through dozens of new fea

  17. Library Locations

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Carnegie Library of Pittsburgh locations including address, coordinates, phone number, square footage, and standard operating hours. The map below does not display...

  18. 23 CFR 450.324 - Development and content of the transportation improvement program (TIP).

    Science.gov (United States)

    2010-04-01

    ... Programming § 450.324 Development and content of the transportation improvement program (TIP). (a) The MPO, in...) Emergency relief projects (except those involving substantial functional, locational, or capacity changes...

  19. Relationship between the light environment and carbohydrates in needles of Scots pine (Pinus sylvestris) on a dune

    International Nuclear Information System (INIS)

    Klõšeiko, J.

    2003-01-01

    The fraction of photosynthetically active radiation transmitted through the canopy (FPAR) on a forested dune was measured at different locations with a ceptometer, and the correlations of carbohydrates in Scots pine needles with FPAR were studied. The hypothesis was that the sucrose content is relatively stable in different light environments and the main effect of the location on the dune is expressed on the glucose content in needles assuming that glucose regulates the balance between the light environment and nutritional conditions influencing the carbohydrate production and demand processes in trees. The contents of the investigated carbohydrates did not correlate with the FPAR, which was significantly elevated at the higher locations on the dune (500 per cent on top) relative to the locations on the foot. The concentrations of hexoses varied substantially between the individual branches or trees from the same plots and between plots, while sucrose levels on single plots were relatively constant. Analysis of variance indicated the effect of the location on the concentrations of sucrose and excess bound fructose, and on the total content of carbohydrates in current-year needles in which the investigated parameters were positively correlated with the respective parameters in one-year-old needles. The results indicate that the content of carbohydrates does not directly depend on the light environment on the dune, though the large variance in the content of hexoses possibly requires increasing the number of samples on each plot to reveal the differences in needles between the locations on the dune

  20. Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Eichler, Katrin; Siebenhandl, Petra; Gruber-Rouh, Tatjana; Vogl, Thomas Josef; Zangos, Stephan [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Czerny, Christoph [Goethe University Hospital, Department of Trauma Surgery, Frankfurt (Germany)

    2013-01-15

    To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software. A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluoroscopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed. All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min). When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories. (orig.)

  1. Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

    International Nuclear Information System (INIS)

    Schulz, Boris; Eichler, Katrin; Siebenhandl, Petra; Gruber-Rouh, Tatjana; Vogl, Thomas Josef; Zangos, Stephan; Czerny, Christoph

    2013-01-01

    To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software. A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluoroscopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed. All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min). When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories. (orig.)

  2. Solitonlike attractor for blood vessel tip density in angiogenesis

    Science.gov (United States)

    Bonilla, L. L.; Carretero, M.; Terragni, F.

    2016-12-01

    Recently, numerical simulations of a stochastic model have shown that the density of vessel tips in tumor-induced angiogenesis adopts a solitonlike profile [Sci. Rep. 6, 31296 (2016), 10.1038/srep31296]. In this work, we derive and solve the equations for the soliton collective coordinates that indicate how the soliton adapts its shape and velocity to varying chemotaxis and diffusion. The vessel tip density can be reconstructed from the soliton formulas. While the stochastic model exhibits large fluctuations, we show that the location of the maximum vessel tip density for different replicas follows closely the soliton peak position calculated either by ensemble averages or by solving an alternative deterministic description of the density. The simple soliton collective coordinate equations may also be used to ascertain the response of the vessel network to changes in the parameters and thus to control it.

  3. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  4. Needle Biopsy of the Lung

    Science.gov (United States)

    ... out of this tunnel. Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite ... consists of a radiographic table, one or two x-ray tubes and a television-like monitor that is located ...

  5. The tip of the iceberg

    DEFF Research Database (Denmark)

    Bjørst, Lill Rastad

    2010-01-01

      Abstract: The tip of the iceberg: Ice as a nonhuman actor of the climate change debate   The global climate change debate has the Arctic as a core region of concern and ice has become a central aspect of discourses. This article discusses ice representations from six different contexts linked...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ... of Use | Links | Site Map Copyright © 2018 ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver and reduces abnormally high blood pressure in the veins of the stomach, esophagus, bowel and liver, reducing the risk of bleeding from enlarged veins across the esophagus ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... failure is severe, a TIPS may not be the best use and a different procedure may be needed to control your symptoms. They are also at risk for encephalopathy , which is an alteration of normal brain function that can lead to confusion. This is ...

  9. Food Allergy: Tips to Remember

    Science.gov (United States)

    ... or get better on their own. Outgrowing Food Allergies Most children outgrow their allergies to cow’s milk, egg, soy ... can help you learn when you or your child’s food allergies are resolving with time. Healthy Tips • Always ask ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening liver failure ...

  11. Assigning Effective Homework. Classroom Tips

    Science.gov (United States)

    American Federation of Teachers (NJ), 2010

    2010-01-01

    Each new school year brings high hopes, great expectations and challenges for both new and seasoned educators. The American Federation of Teachers (AFT) has developed a series called "Classroom Tips" to help educators start the year right and anticipate the year ahead. Over the past 40 years, most research studies on homework have found that…

  12. Raman Spectroscopy Differentiates Each Tissue From the Skin to the Spinal Cord: A Novel Method for Epidural Needle Placement?

    Science.gov (United States)

    Anderson, T. Anthony; Kang, Jeon Woong; Gubin, Tatyana; Dasari, Ramachandra R.; So, Peter T. C.

    2016-01-01

    BACKGROUND Neuraxial anesthesia and epidural steroid injection techniques require precise anatomical targeting to ensure successful and safe analgesia. Previous studies suggest that only some of the tissues encountered during these procedures can be identified by spectroscopic methods, and no previous study has investigated the use of Raman, diffuse reflectance, and fluorescence spectroscopies. The authors hypothesized that real-time needle-tip spectroscopy may aid epidural needle placement and tested the ability of spectroscopy to distinguish each of the tissues in the path of neuraxial needles. METHODS For comparison of detection methods, the spectra of individual, dissected ex vivo paravertebral and neuraxial porcine tissues were collected using Raman spectroscopy (RS), diffuse reflectance spectroscopy (DRS), and fluorescence spectroscopy (FS). Real-time spectral guidance was tested using a 2 mm inner diameter fiber optic probe-in-needle device. Raman spectra were collected during the needle’s passage through intact paravertebral and neuraxial porcine tissue and analyzed afterward. The RS tissue signatures were verified as mapping to individual tissue layers using histochemical staining and widefield microscopy. RESULTS Raman spectroscopy revealed a unique spectrum for all ex vivo paravertebral and neuraxial tissue layers; DRS and FS spectra were not distinct for all tissues. Moreover, when accounting for the expected order of tissues, real-time Raman spectra recorded during needle insertion also permitted identification of each paravertebral and neuraxial porcine tissue. CONCLUSIONS This study demonstrates Raman spectroscopy can distinguish the tissues encountered during epidural needle insertion. This technology may prove useful during needle placement by providing evidence of its anatomical localization. PMID:27466032

  13. Aperiodicity Correction for Rotor Tip Vortex Measurements

    Science.gov (United States)

    Ramasamy, Manikandan; Paetzel, Ryan; Bhagwat, Mahendra J.

    2011-01-01

    The initial roll-up of a tip vortex trailing from a model-scale, hovering rotor was measured using particle image velocimetry. The unique feature of the measurements was that a microscope was attached to the camera to allow much higher spatial resolution than hitherto possible. This also posed some unique challenges. In particular, the existing methodologies to correct for aperiodicity in the tip vortex locations could not be easily extended to the present measurements. The difficulty stemmed from the inability to accurately determine the vortex center, which is a prerequisite for the correction procedure. A new method is proposed for determining the vortex center, as well as the vortex core properties, using a least-squares fit approach. This approach has the obvious advantage that the properties are derived from not just a few points near the vortex core, but from a much larger area of flow measurements. Results clearly demonstrate the advantage in the form of reduced variation in the estimated core properties, and also the self-consistent results obtained using three different aperiodicity correction methods.

  14. Structural properties 3,16-bis triisopropylsilylethynyl (pentacene) (TIPS-pentacene) thin films onto organic dielectric layer using slide coating method

    International Nuclear Information System (INIS)

    Rusnan, Fara Naila; Mohamad, Khairul Anuar; Seria, Dzul Fahmi Mohd Husin; Saad, Ismail; Ghosh, Bablu K.; Alias, Afishah

    2015-01-01

    3,16-bis triisopropylsilylethynyl (Pentacene) (TIPS-Pentacene) compactable interface property is important in order to have a good arrangement of molecular structure. Comparison for TIPS-Pentacene deposited between two different surface layers conducted. 0.1wt% TIPS-Pentacene diluted in chloroform were deposited onto poly(methylmeaclyrate) (PMMA) layered transparent substrates using slide coating method. X-ray diffraction (XRD) used to determine crystallinity of thin films. Series of (00l) diffraction peaks obtained with sharp first peaks (001) for TIPS-Pentacene deposited onto PMMA layer at 5.35° and separation of 16.3 Å. Morphology and surface roughness were carried out using scanning electron microscope (SEM) and surface profilemeter LS500, respectively.TIPS-Pentacene deposited onto PMMA layer formed needled-like-shape grains with 10.26 nm surface roughness. These properties were related as thin film formed and its surface roughness plays important role towards good mobility devices

  15. Structural properties 3,16-bis triisopropylsilylethynyl (pentacene) (TIPS-pentacene) thin films onto organic dielectric layer using slide coating method

    Energy Technology Data Exchange (ETDEWEB)

    Rusnan, Fara Naila; Mohamad, Khairul Anuar; Seria, Dzul Fahmi Mohd Husin; Saad, Ismail; Ghosh, Bablu K.; Alias, Afishah [Nano Engineering & Materials (NEMs) Research Group, Faculty of Engineering Universiti Malaysia Sabah, Kota Kinabalu 88400 Sabah (Malaysia)

    2015-08-28

    3,16-bis triisopropylsilylethynyl (Pentacene) (TIPS-Pentacene) compactable interface property is important in order to have a good arrangement of molecular structure. Comparison for TIPS-Pentacene deposited between two different surface layers conducted. 0.1wt% TIPS-Pentacene diluted in chloroform were deposited onto poly(methylmeaclyrate) (PMMA) layered transparent substrates using slide coating method. X-ray diffraction (XRD) used to determine crystallinity of thin films. Series of (00l) diffraction peaks obtained with sharp first peaks (001) for TIPS-Pentacene deposited onto PMMA layer at 5.35° and separation of 16.3 Å. Morphology and surface roughness were carried out using scanning electron microscope (SEM) and surface profilemeter LS500, respectively.TIPS-Pentacene deposited onto PMMA layer formed needled-like-shape grains with 10.26 nm surface roughness. These properties were related as thin film formed and its surface roughness plays important role towards good mobility devices.

  16. Gene Locater

    DEFF Research Database (Denmark)

    Anwar, Muhammad Zohaib; Sehar, Anoosha; Rehman, Inayat-Ur

    2012-01-01

    software's for calculating recombination frequency is mostly limited to the range and flexibility of this type of analysis. GENE LOCATER is a fully customizable program for calculating recombination frequency, written in JAVA. Through an easy-to-use interface, GENE LOCATOR allows users a high degree...... of flexibility in calculating genetic linkage and displaying linkage group. Among other features, this software enables user to identify linkage groups with output visualized graphically. The program calculates interference and coefficient of coincidence with elevated accuracy in sample datasets. AVAILABILITY......: The database is available for free at http://www.moperandib.com....

  17. Mini-flared Kelman tip, reverse tip, and sidewinder tip with torsional phaco: a prospective randomized comparative study

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2015-02-01

    Full Text Available Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA, endothelial cell counts (ECC, and preoperative and 1-day postoperative central corneal thickness (CCT. Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE, and balanced salt solution volume (BSS. Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02 than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009. There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05. Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip.

  18. Parenting Tips: How to Improve Toddler Behavior

    Science.gov (United States)

    ... issues. To encourage listening and cooperation, follow these parenting tips. By Mayo Clinic Staff Life can be ... and a degree of routine. Consider these practical parenting tips. Make sure your displays of affection for ...

  19. Tips for Good Oral Health during Pregnancy

    Science.gov (United States)

    Tips for Good Oral Health During Pregnancy B elow are tips for taking care of your oral health while you are pregnant. Getting oral health care, practicing good oral hygiene, eating healthy foods, ...

  20. School Avoidance: Tips for Concerned Parents

    Science.gov (United States)

    ... Email Print Share School Avoidance: Tips for Concerned Parents Page Content ​School avoidance – sometimes called school refusal ... school bully) Actual physical harm Tips for Concerned Parents: As a first step, the management of school ...

  1. [Study on the angle and depth of needle insertion at Huantiao (GB 30) by three-dimensional reconstruction].

    Science.gov (United States)

    Liu, Yan-Xiang; Yan, Zhen-Guo; Guo, Yi; Zhuang, Tian-Ge; Shao, Shui-Jin; Jiang, Jun

    2012-10-01

    To observe the anatomic structure of Huantiao (GB 30) visually, to imitate the inserting process of the needle to explore the safty of needle insertion and improve the therapeutic effect of acupuncture in clinic. Combined with anatomic structure of acupoint, muscles and other tissues related with Huantiao (GB 30) were interactively segmented in VOXEL-MAN with the computer graphics technology. Nerves and blood vessels were reconstructed by establishing mathematic model, and the needle-inserting animation of Huantiso (GB 30) was obtained by running script file. The three-dimensional (3-D) visualization of Huantiao (GB 30) on needle-inserting animation was accomplished, the spatial location and expression of Huantiao (GB 30) in the digitized virtual human body were observed, the virtual inserting process was imitated realistically, and the 3-D animation of needle insertion at Huantiao (GB 30) was created. Building mathematic model is favorable for expressing the anatomic structure of Huantiao (GB 30) in 3-D space, imitating the process of needle insertion realistically and observing the spatial structure of the point and the around tissues, which can provide a solid foundation for the safety of needle insertion of acupoints and improve therapeutic effect of acupuncture in clinic.

  2. Characterization of Fungal Pathogens Associated with White Pine Needle Damage (WPND in Northeastern North America

    Directory of Open Access Journals (Sweden)

    Kirk Broders

    2015-11-01

    Full Text Available Eastern white pine is a crucial ecological and economic component of forests in the northern USA and eastern Canada, and is now facing an emerging problem in white pine needle damage (WPND. It is still unclear whether WPND results from one, or the combination of several fungal pathogens. Therefore, the first objective of this study was to characterize the fungi associated with WPND in the northeastern United States and document the damage being done to mature eastern white pine as a result of repeated defoliation. To date, 22 species of fungi, either cultured from diseased pine needles or formed fruiting bodies on pine needles were identified based on morphology and sequence data. Lecanosticta acicola and a putative new species of Septorioides were the species most frequently recovered from diseased needles, in addition to needle cast fungi Lophophacidium dooksii and Bifusella linearis, two obligate fungal pathogens that were frequently observed on pine needles in the northeast, but have not been known to cause excessive defoliation of eastern white pine. A second objective was to monitor yearly the health of 63 pairs of healthy and unhealthy trees in eight affected locations throughout New England. Since 2012, affected trees are increasingly and repeatedly chlorotic and defoliated every year. Trees that were initially healthy are now exhibiting symptoms. While L. acicola appears to be the primary pathogen causing WPND, several other common needle pathogens are being more frequently observed and the role of climate change may be important in the disease ecology of WPND. These defoliation events, while once a sporadic occurrence, have now become more frequent as observed in continued crown deterioration of eastern white pine in long-term monitoring plots followed during the course of this three-year study.

  3. Utilization of No-Kor needles for slit-micrografting.

    Science.gov (United States)

    Brandy, D A; Meshkin, M

    1994-05-01

    This article introduces the No-Kor vented needle as an excellent tool for micrograft recipient site development. To show that No-Kor vented needles are better than conventional hypodermic needles (with and without dilators) and Bard Parker blades for micrograft recipient site development. Comparisons with hypodermic needles (with and without dilators) and Bard Parker blade incisions are made. When compared with hypodermic needles (with and without dilators, the No-Kor needles show less scarring, allow easier placement, take less surgical time, and are less expensive. When compared with Bard Parker blade incisions, the No-Kor needles demonstrate less scarring, more precision, and less expense. The No-Kor vented needle is an excellent tool for the development of micrograft recipient sites. It demonstrates advantages over both hypodermic needles and Bard Parker blades.

  4. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  5. The cellularity yield of three different 22-gauge endoscopic ultrasound fine needle aspiration needles.

    Science.gov (United States)

    Othman, Mohamed O; Abdelfatah, Mohamed M; Padilla, Osvaldo; Hussinat, Maha; Elhanafi, Sherif; Eloliby, Mohamed; Torabi, Alireza; Hakim, Nawar; Boman, Darius A

    2017-05-01

    Endoscopic ultrasound (EUS) fine needle aspiration (FNA) is an integral part in the diagnosis of pancreatic, intestinal and extra-intestinal masses or lesions. There is no clear data on the superiority of the core biopsy needle over standard 22-gauge needles. The aim of this study is to prospectively compare the cellularity yield of three commonly used 22-gauge FNA needles available in the US market. This is a prospective, randomized study comparing the cellularity yield of three commercially available EUS needles (two standard FNA needles and core biopsy needle). Two blinded pathologists evaluated the cytology specimens based on an already agreed upon cytology score. We included adult patients (18-80 years old) who presented to our endoscopy unit for FNA of pancreatic or extrapancreatic masses. 109 patients (57 F, 52 M) were recruited to the study, 88 lesions were pancreatic lesions. 39 patients were recruited in the EZ Shot 2™ group, 36 in the Procore ® group and 34 in the Expect™ group. The average cellularity score and the mean number of passes (SD) were not different between the three needles; P = 0.91 and P = 0.16, respectively. There was no difference between the three needles in obtaining an onsite diagnosis (P = 0.627) and no difference in reported adverse events between the three groups. The cellularity yields, the mean number of passes and reported adverse events were similar in the three compared 22-gauge needles. Diagn. Cytopathol. 2017;45:426-432. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. Probing Access Resistance of Solid-state Nanopores with a Scanning Probe Microscope Tip.

    Science.gov (United States)

    Hyun, Changbae; Rollings, Ryan; Li, Jiali

    2012-02-06

    An apparatus that integrates solid-state nanopore ionic current measurement with a Scanning Probe Microscope has been developed. When a micrometer-scale scanning probe tip is near a voltage biased nanometer-scale pore (10-100 nm), the tip partially blocks the flow of ions to the pore and increases the pore access resistance. The apparatus records the current blockage caused by the probe tip and the location of the tip simultaneously. By measuring the current blockage map near a nanopore as a function of the tip position in 3D space in salt solution, we estimate the relative pore resistance increase due to the tip, ΔR/R(0), as a function of the tip location, nanopore geometry, and salt concentration. The amplitude of ΔR/R(0) also depends on the ratio of the pore length to its radius as Ohm's law predicts. When the tip is very close to the pore surface, ~10 nm, our experiments show that ΔR/R(0) depends on salt concentration as predicted by the Poisson and Nernst-Planck equations. Furthermore, our measurements show that ΔR/R(0) goes to zero when the tip is about five times the pore diameter away from the center of the pore entrance. The results in this work not only demonstrate a way to probe the access resistance of nanopores experimentally, they also provide a way to locate the nanopore in salt solution, and open the door to future nanopore experiments for detecting single biomolecules attached to a probe tip.

  7. Probing access resistance of solid-state nanopores with a scanning-probe microscope tip.

    Science.gov (United States)

    Hyun, Changbae; Rollings, Ryan; Li, Jiali

    2012-02-06

    An apparatus that integrates solid-state nanopore ionic current measurement with a scanning-probe microscope is developed. When a micrometer-scale scanning-probe tip is near a voltage-biased nanometer-scale pore (10–100 nm), the tip partially blocks the flow of ions to the pore and increases the pore access resistance. The apparatus records the current blockage caused by the probe tip and the location of the tip simultaneously. By measuring the current blockage map near a nanopore as a function of the tip position in 3D space in salt solution, the relative pore resistance increases due to the tip and ΔR/R0 is estimated as a function of the tip location, nanopore geometry, and salt concentration. The amplitude of ΔR/R0 also depends on the ratio of the pore length to its radius as Ohm's law predicts. When the tip is very close to the pore surface, ≈10 nm, experiments show that ΔR/R0 depends on salt concentration as predicted by the Poisson and Nernst–Planck equations. Furthermore, the measurements show that ΔR/R0 goes to zero when the tip is about five times the pore diameter away from the center of the pore entrance. The results in this work not only demonstrate a way to probe the access resistance of nanopores experimentally; they also provide a way to locate the nanopore in salt solution, and open the door to future nanopore experiments for detecting single biomolecules attached to a probe tip. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Injector tip for an internal combustion engine

    Science.gov (United States)

    Shyu, Tsu Pin; Ye, Wen

    2003-05-20

    This invention relates to a the tip structure of a fuel injector as used in a internal combustion engine. Internal combustion engines using Homogeneous Charge Compression Ignition (HCCI) technology require a tip structure that directs fuel spray in a downward direction. This requirement necessitates a tip design that is capable of withstanding mechanical stresses associated with the design.

  9. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  10. Unconsciously penetrated foreign body (sewing needle injury

    Directory of Open Access Journals (Sweden)

    Musa Zorlu

    2015-12-01

    Full Text Available The injuries of foreign body in work accidents are often seen in adults. It could be diagnosed in different parts of the body. In this study, a twenty year old woman who had a pain in the left axillary region of the body, a constraint on joint movement coordination center and high fever is not aware of the needle in her body was examined. There was a sewing needle penetrates to pectoralis major muscle at the left axillary region of the body seen in her anterior posterior chest x ray. It was removed under general anesthesia using fluoroscopy. Patients could have different clinical complaints due to the mobile sewing needle in different parts of the body. The questioning of her profession history and physical examination would help for diagnosis of the complaints in the evaluation of patients. [J Contemp Med 2015; 5(4.000: 265-268

  11. NMR identification of the binding surfaces involved in the Salmonella and Shigella Type III secretion tip-translocon protein-protein interactions.

    Science.gov (United States)

    McShan, Andrew C; Kaur, Kawaljit; Chatterjee, Srirupa; Knight, Kevin M; De Guzman, Roberto N

    2016-08-01

    The type III secretion system (T3SS) is essential for the pathogenesis of many bacteria including Salmonella and Shigella, which together are responsible for millions of deaths worldwide each year. The structural component of the T3SS consists of the needle apparatus, which is assembled in part by the protein-protein interaction between the tip and the translocon. The atomic detail of the interaction between the tip and the translocon proteins is currently unknown. Here, we used NMR methods to identify that the N-terminal domain of the Salmonella SipB translocon protein interacts with the SipD tip protein at a surface at the distal region of the tip formed by the mixed α/β domain and a portion of its coiled-coil domain. Likewise, the Shigella IpaB translocon protein and the IpaD tip protein interact with each other using similar surfaces identified for the Salmonella homologs. Furthermore, removal of the extreme N-terminal residues of the translocon protein, previously thought to be important for the interaction, had little change on the binding surface. Finally, mutations at the binding surface of SipD reduced invasion of Salmonella into human intestinal epithelial cells. Together, these results reveal the binding surfaces involved in the tip-translocon protein-protein interaction and advance our understanding of the assembly of the T3SS needle apparatus. Proteins 2016; 84:1097-1107. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Dry needling versus acupuncture: the ongoing debate.

    Science.gov (United States)

    Zhou, Kehua; Ma, Yan; Brogan, Michael S

    2015-12-01

    Although Western medical acupuncture (WMA) is commonly practised in the UK, a particular approach called dry needling (DN) is becoming increasingly popular in other countries. The legitimacy of the use of DN by conventional non-physician healthcare professionals is questioned by acupuncturists. This article describes the ongoing debate over the practice of DN between physical therapists and acupuncturists, with a particular emphasis on the USA. DN and acupuncture share many similarities but may differ in certain aspects. Currently, little information is available from the literature regarding the relationship between the two needling techniques. Through reviewing their origins, theory, and practice, we found that DN and acupuncture overlap in terms of needling technique with solid filiform needles as well as some fundamental theories. Both WMA and DN are based on modern biomedical understandings of the human body, although DN arguably represents only one subcategory of WMA. The increasing volume of research into needling therapy explains its growing popularity in the musculoskeletal field including sports medicine. To resolve the debate over DN practice, we call for the establishment of a regulatory body to accredit DN courses and a formal, comprehensive educational component and training for healthcare professionals who are not physicians or acupuncturists. Because of the close relationship between DN and acupuncture, collaboration rather than dispute between acupuncturists and other healthcare professionals should be encouraged with respect to education, research, and practice for the benefit of patients with musculoskeletal conditions who require needling therapy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. The use of electrical stimulation to guide epidural and intrathecal needle advancement at the L5 -L6 intervertebral space in dogs.

    Science.gov (United States)

    Otero, Pablo E; Verdier, Natali; Ceballos, Martin R; Tarragona, Lisa; Flores, Myriam; Portela, Diego A

    2014-09-01

    To determine the minimal electrical threshold (MET) necessary to elicit appropriate muscle contraction when the tip of an insulated needle is positioned epidurally or intrathecally at the L5-6 intervertebral space (phase-I) and to determine whether the application of a fixed electrical current during its advancement could indicate needle entry into the intrathecal space (phase-II) in dogs. Prospective, blinded study. Thirteen (phase-I) and seventeen (phase-II) dogs, scheduled for a surgical procedure where L5-6 intrathecal administration was indicated. Under general anesthesia, an insulated needle was first inserted into the L5-6 epidural space and secondly into the intrathecal space and the MET necessary to obtain a muscular contraction of the pelvic limb or tail at each site was determined (phase-I). Under similar conditions, in dogs of phase-II an insulated needle was inserted through the L5-6 intervertebral space guided by the use of a fixed electrical current (0.8 mA) until muscular contraction of the pelvic limb or tail was obtained. Intrathecal needle placement was confirmed by either free flow of cerebrospinal fluid (CSF) or myelography. The current required to elicit a motor response was significantly lower (p dogs. This study demonstrates the feasibility of using an electrical stimulation test to confirm intrathecal needle position in dogs. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  14. Comparison of design features and mechanical properties of commercially available Veress needles.

    Science.gov (United States)

    Schramel, Johannes P; Kindslehner, Angelika; Bockstahler, Barbara A; Dupré, Gilles P

    2017-10-01

    To compare design features and mechanical properties of 13 commercially available Veress needles (VN). In vitro biomechanical study. Veress needles from 9 manufacturers (6 reusable, 6 disposable, and 1 with a reusable stylet combined with a disposable cannula) were included in the study. Veress needles are designed with a spring-loaded stylet to protect the tip of the cannula following insertion into the abdomen. Stylet forces were measured with a scale in a test jig by moving the stylet in 0.5 mm steps into the hollow cannula. Forces and spring rates were derived from force-displacement plots. Mass, mechanical dimensions, and the bevel angle and geometry were assessed. Differences between VN models were analyzed with a univariate analysis of variance. Results are reported as mean ± SD or median (range). Physical and mechanical parameters differed between models. The exposed stylet length was 3.5 mm (2-7). Three bevel geometries (bias, lancet type, and back-cut) with angles between 20° and 40° were identified. Reusable VN weigh more (24.9 ± 2.2 g) than disposable designs (6.0 ± 2.3 g). The mean values for the spring rate and the residual stylet force were 0.23 ± 0.08 Nmm -1 and 0.94 ± 0.28 N, respectively. The mean force required to move the stylet to the cannula tip was 1.81 ± 0.29 N and 2.77 ± 0.54 N to move to the proximal end of the bevel. Commercially available VN use diverse bevel geometries and have different mechanical characteristics. Studies investigating laparoscopic entry complications should explicitly report the type of VN model used. © 2017 The American College of Veterinary Surgeons.

  15. The role of MR angiography before transjugular placement of a portosystemic stent shunt (TIPS)

    International Nuclear Information System (INIS)

    Mueller, M.F.; Siewert, B.; Kim, D.; Edelman, R.R.; Stokes, K.R.; Finn, J.P.

    1994-01-01

    The authors employed magnetic resonance angiography (MRA) to guide catheter placement for transjugular intrahepatic portosystemic stent shunt (TIPS) procedures in 14 of 24 patients, and compared the results to the 10 patients who did not have prior panning based on MRA. Two-dimensional time-of-flight venography was performed during breath holding, and projection venograms were formatted in sagittal, coronal and axial planes. MRA defined venous anatomy sufficiently well to shorten the procedure and helped to minimize invasiveness. With MRA guidance, intrahepatic needle punctures were significantly fewer (without MRA guidance: mean 12.1; with MRA guidance: mean 3.5, p [de

  16. Penetrating cardiac injury following sewing needle ingestion.

    Science.gov (United States)

    Sobnach, Sanju; Castillo, Franco; Blanco Vinent, René; Kahn, Delawir; Bhyat, Ahmed

    2011-07-01

    Penetrating cardiac injuries are common in South Africa. Reports describing traumatic lesions to the heart caused by caudo-cranial migration of ingested foreign bodies are however extremely rare. Delayed presentation and intervention are associated with poor outcome in these patients; cardiac tamponade remains the most serious complication. We present the case of a 19 year-old man who sustained a left ventricular injury after intentionally swallowing eight sewing needles. The impacted needle was removed through a median sternotomy and the patient recovered uneventfully. Copyright © 2011 Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Published by Elsevier B.V. All rights reserved.

  17. [King Injo's disease and burnt needle therapy].

    Science.gov (United States)

    Kim, In-Sook

    2004-12-01

    This paper investigates an interrelationship between burnt needle therapy and King Injo's disease. From 1633 (Year 11 in King Injo's reign) to May 5, 1649 (Year 27 in King Injo's reign), right before his death, King Injo was treated with burnt needles by Yi Hyeongik, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have?Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon ear, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease. The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong derived from her mother, Queen Mother Inmok. Moral justification for King Injo's coup was Gwanghaegun or Prince Gwanghae's immoral conduct toward Queen Mothe Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant rebellions and treasons threatened King Injo. The king suspected that Queen Mother

  18. King Injo's Disease and Burnt Needle Therapy

    Directory of Open Access Journals (Sweden)

    KIM In-Sook

    2004-12-01

    Full Text Available This paper investigates an interrelationship between burnt needle therapy(번침 and King Injo'sdisease. From 1633 (Year 11 in King Injo's reign to May 5, 1649 (Year 27 King in Injo's reign, right before his death, King Injo(인조 was treated with burnt needles by Yi Hyeongik(이형익, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have? Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon era, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease.  The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong(정명공주 derived from her mother, Queen Mother Inmok(인목대비. Moral justification for King Injo's coup was Gwanghaegun(광해군 or Prince Gwanghae's immoral conduct toward Queen Mother Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant

  19. Etiological studies on needle fungi associated with semimature-tissue needle blight of eastern white pine

    Energy Technology Data Exchange (ETDEWEB)

    Linzon, S.N.

    1968-01-01

    The results of etiological studies on semimature-tissue needle blight (SNB) of eastern white pine (Pinus strobus L.) deny any role to needle fungi as the primary cause. No mycelium was found in newly blighted semimature tissue by either cultural or histological methods. Mycelia of several saprophytic fungi were isolated from the blighted portions of current year needles about 2 weeks after the onset of SNB, and fruit-bodies of different organisms were found to occur both in the interior and on the exterior of blighted needles about 4 weeks after the first occurrence of disease symptoms. The morphological development of apothecia of C. acuum was studied. Hysterothecia of Lophodermium spp. (L. pinastri (Schrad. ex Fr.) Chev. and L. nitens Darker) occurred ubiquitously on fallen white pine needles. Aerial spore trapping showed that ascospores of C. acuum were abundant, those of Lophodermium spp. were prevalent, and those of H. desmazierii were practically non-existent in the area investigated. There was little coincidence between the occurrence of SNB outbreaks and peak populations of air-borne ascospores of these fungi. Ascospore suspensions and needles bearing fructifications of C. acuum and Lophodermium spp. were used to inoculate the newly developing needles of SNB-susceptible and non-susceptible field trees and potted seedlings, but the typical symptoms of SNB did not develop as a result of these inoculations. Two fungicides, captan and Bordeaux mixture, were applied to SNB-susceptible and non-susceptible field trees throughout the growing season, but neither fungicide prevented the symptoms of SNB from appearing on the new needles of susceptible trees at the same time as they appeared on untreated susceptible trees in the area. The fungicidal sprays, however, did prevent saprophyttic fungi from invading blighted portions of the needles. It is concluded from this investigation that SNB is not a disease of fungal origin. 19 references, 17 figures, 3 tables.

  20. Percutaneous Radiofrequency Ablation of Osteoid Osteomas with Use of Real-Time Needle Guidance for Accurate Needle Placement: A Pilot Study

    International Nuclear Information System (INIS)

    Busser, Wendy M. H.; Hoogeveen, Yvonne L.; Veth, Rene P. H.; Schreuder, H. W. Bart; Balguid, Angelique; Renema, W. KlaasJan; SchultzeKool, Leo J.

    2011-01-01

    Purpose: To evaluate the accuracy and technical success of positioning a radiofrequency ablation (RFA) electrode in osteoid osteomas by use of a new real-time needle guidance technology combining cone-beam computed tomography (CT) and fluoroscopy. Materials and Methods: Percutaneous RFA of osteoid osteomas was performed in five patients (median age 18 years), under general anesthesia, with the use of cone-beam CT and fluoroscopic guidance for electrode positioning. The outcome parameters were technical success, meaning correct needle placement in the nidus; accuracy defined as the deviation (in mm) from the center of the nidus; and clinical outcome at follow-up. Results: In all five cases, positioning was possible within 3 mm of the determined target location (median nidus size 6.8 mm; range 5–10.2 mm). All procedures were technically successful. All patients were free of pain at clinical follow-up. No complications were observed. Conclusion: Real-time fluoroscopy needle guidance based on cone-beam CT is a useful tool to accurately position radiofrequency needles for minimally invasive treatment of osteoid osteomas.

  1. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Camille Chesnel

    Full Text Available Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia.To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers.Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred.Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%: 4 (1% in tendons or muscles, 3 (0.7% in nerves and 1 (0.2% in a vessel.This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  2. Sediment transport via needle ice: a new method for diffusive transport on laboratory-scale hillslopes

    Science.gov (United States)

    Sweeney, K. E.; Roering, J. J.; Rempel, A. W.

    2012-12-01

    Convex hilltops formed by diffusive sediment transport are a fundamental feature of soil-mantled landscapes worldwide. Additionally, the competition and interaction between hillslopes and valleys control basic topographic metrics, such as relief, drainage density, and breaks in slope-area scaling. Despite recent progress in erosive landscape experiments, no published work has explored the competition of hillslope diffusion and channel advection experimentally. Here, we present preliminary findings on the plausibility of needle ice driven frost creep as a mechanism for laboratory hillslope transport of wet sediment. In nature, needle ice is a diurnal form of ice segregation, whereby liquid water held in sediment pore space is driven upward toward a near-surface freezing front by a temperature-controlled liquid pressure gradient. As needles grow perpendicular to the surface, sediment is incorporated in the growing needle ice by temperature perturbations and associated downward shifts in the freezing front. Sediment then moves downslope due to melting or sublimation of the ice needles. We constructed a slope of saturated sediment in a freezer to constrain the temperature, grain size, and soil moisture limits on laboratory needle ice growth and sediment transport. Surficial sediment transport is measured during experimentation by tracking the movement of colored grains. Additionally, at the end of each run we measure depth-dependent sediment transport by taking slices of the experimental slope and observing the displacement of buried columns of colored grains. In agreement with past work, we find that with temperatures just below freezing, soil moisture above 35%, and silt-sized sediment, the moisture migration induced by freezing releases enough latent heat to maintain the location of the freezing front and encourage needle ice growth. Our experiments demonstrate that the amount of sediment incorporated during needle growth, i.e., the transport efficiency, can be

  3. Effect of ponderosa pine needle litter on grass seedling survival.

    Science.gov (United States)

    Burt R. McConnell; Justin G. Smith

    1971-01-01

    Hard fescue survival rates were followed for 6 years on four different pine needle treatment plots. Needle litter had a significant effect on initial survival of fescue seedlings, but subsequent losses undoubtedly resulted from the interaction of many factors.

  4. Morphology of jack pine and tamarack needles in dense stands.

    Science.gov (United States)

    Terry F. Strong; J. Zavitkovski

    1978-01-01

    Effects of position in the crown on needle morphology and surface area were studied. Needle length, surface area, and dry weight increased and specific needs area decreased from the lower to the upper third of the crown.

  5. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  6. SELF-REPORTED EXPERIENCES AND PERCEPTIONS RELATED TO NEEDLE STICK INJURIES IN A TERTIARY CARE HOSPITAL IN COASTAL ANDHRA PRADESH

    Directory of Open Access Journals (Sweden)

    Sai Shankar

    2016-03-01

    Full Text Available INTRODUCTION Needle Stick Injury, a preventable problem, is a serious concern for all health care providers and workers and poses a significant risk of occupational transmission of blood borne pathogens such as HIV, HBV, HCV and some others. Relevant literature is scanty from India and none could be located from coastal Andhra Pradesh. The present study aims at determining the occurrence of Needle Stick Injuries in various categories of health workers in a tertiary care teaching hospital in coastal Andhra Pradesh, factors associated with these Needle Stick Injuries, circumstances under which they occur and the responses of the health care workers following the injury. The study also aims at assessing the awareness levels of the health care workers regarding diseases transmitted through Needle Stick Injuries. MATERIALS AND METHODS After getting the permission from the authorities of KIMS&RF and clearance from IEC of KIMS&RF, an institution based crosssectional study on health care providers involved in diagnosis and treatment of patients and the cleaning staff using predesigned and pretested questionnaire was done after seeking their consent. The data collected included basic demographics of the study subjects, professional status and work experience, history of Needle Stick Injury during the last three years while on their job and the relevant details, perceptions regarding Needle Stick Injuries, knowledge on diseases associated with it and information regarding training on Universal Work Precautions. The data was entered in Microsoft Excel worksheet and analysed statistically using Epi Info version 6 software. RESULTS Of the 353 study subjects (97 males and 256 females who answered the questionnaire, 53% reported to have experienced Needle Stick Injuries and 94% of study subjects believed it to be an important problem. About 43 % met with Needle Stick Injury more than once in the last 3 years. Only 30% reported about the injury and 31% did

  7. [Thinking and status of research on acupoint temperature sensor needle].

    Science.gov (United States)

    Xu, Gang; Yang, Hua-yuan; Liu, Tang-yi; Gao, Ming; Hu, Yin-e

    2010-09-01

    ABSTRACT Based on acupoint temperature sensor needle related literatures, the development and the applications of temperature sensor needle and the measuring instrument which is used for measuring the temperature of acupoints are introduced in the present paper. This paper summarizes the basic structure and measuring principle of temperature sensor needle; it also summarizes the hardware and measuring procedures of the measuring instrument. According to the characteristics of the temperature sensor needle, this paper states its broad applications and development trend.

  8. STUDY & ANALYSIS OF MICRO NEEDLE MATERIAL BY ANSYS

    OpenAIRE

    Santosh Kumar Singh*, Prabhat Sinha, N.N. Singh, Nagendra Kumar

    2017-01-01

    In this research the concept of design and analysis, silicon and stainless steel based on hollow micro-needles for transdermal drug delivery(TDD) have been evaluated by Using ANSYS & computational fluid dynamic (CFD), structural. Micro fluidic analysis has performed to ensure the micro-needles design suitability for Drug delivery. The effect of axial and transverse load on single and micro-needle array has investigated with the mechanical properties of micro-needle. The analysis predicte...

  9. Abscisic acid in needles of Pinus cembra in relation to ozone exposure.

    Science.gov (United States)

    Bianco; Dalstein

    1999-10-01

    Ozone pollution was analyzed in arolla pine (Pinus cembra L.) forests growing over two mountain ranges located in southern France by using specific ozone-sensitive tobacco plants as bio-indicators and a physico-chemical analyzer. Concentrations of abscisic acid (ABA) were determined in needles of healthy and declining trees in a massif with a declining forest and in a massif with a healthier forest. In addition, ABA was quantified in needles of trees exposed to either charcoal-filtered air or unfiltered air supplemented with ozone in open-top chambers located at the Col du Donon. The concentration of ABA in needles of injured trees increased when the trees were exposed to ozone either under field conditions or in open-top chambers; however, the difference in ABA concentration between control and ozone-exposed needles was less in the open-top chambers, where ozone was the sole variable, than in the field. The results are discussed in the context of the effects of ozone on plant water relations and hormone-mediated cell defense.

  10. Peribulbar block in equine isolated heads. Development of a single needle technique and tomographic evaluation

    Directory of Open Access Journals (Sweden)

    vanessa rabbogliatti

    2017-05-01

    Full Text Available Peribulbar block (PPB has been used in humans as a safer alternative to retrobulbar block (RBB. PBB, depends on the diffusion of anaesthetic solution into the muscle across the connective tissue and it is performed introducing the needle within the extraconal space. The advantages are fewer complications and palpebral akinesia. In Veterinary Medicine few studies describe this technique in dogs (Ahn J 2013 and cats (Shilo-Benjamini et al. 2013. Based on literature the aim of the study is to determinate, in equine specimens, feasibility of inferior PBB with single needle injection, by using contrast medium (CM, and to evaluate thought Computed Tomography (CT the distribution around the optic nerve (degrees. PBB was performed in 6 orbits. The mixture injected consisted of 20 ml of physiological solution and iodinated CM at 25%. Each periorbital area underwent three CT scans. A basal acquisition to assess the needle position before the injection, a second and third scan were performed immediately after injection, and after application of pressure on the periorbital surface area to promote CM diffusion. The needle position was measured from the tip to the optic nerve with a mean distance of 2,27 mm ± 0,28. The mean volume distribution before pressure application was 23,56 cm3 ± 2,58 and after pressure application was 27,56 cm3 ± 4,8.  The CM distribution, was defined (Nouvellon et al. 2010 “successful” in 4 orbits (>270° and “inadequate” in 2 orbits (<180°. The present study demonstrates feasibility of inferior PBB by single injection in horses for its simple and practical execution. Inferior PPB is a potential alternative to systemic administration of neuromuscular blocking agents for ophthalmic surgery. However, this approach needs to be evaluate in clinical trials to assess its feasibility and effectiveness in clinical practice for standing procedures.

  11. Atypical chest pain: Needles in a haystack

    African Journals Online (AJOL)

    be needles of the type used for sewing. An electrocardiogram showed a minor interference pattern but no ischaemic changes, and the results of blood tests were all within normal limits. An echocardiogram confirmed the presence of foreign bodies in the myocardium (Fig. 2). There was no evidence of valvular defects.

  12. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho

    2017-01-30

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  13. Acylated flavonol glycosides from Larix needles

    NARCIS (Netherlands)

    Niemann, Gerard J.

    2006-01-01

    Kaempferol-3-p-coumarylglucoside (KCG) was isolated from ether fractions of acetone-extracted freeze-dried needles of all larch species investigated. In each case, KCG was found as one of the main flavonoids, whereas often a variety of closely related, acylated flavonoids was present in either

  14. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Background: The increasing prevalence of extrapulmonary manifestation of tuberculosis with the HIV scourge is a cause for concern. Objective: To determine the role of fine needle aspiration cytology (FNAC) in the diagnosis of extrapulmonary tuberculosis. Patients and Methods: This is a consecutive 9-year analysis of ...

  15. The Single Needle Lockstitch Machine. Module 1.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on parts of the machine, one in a series on the single needle lockstitch sewing machine for student self-study, contains eight sections. Each section contains the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  16. Relationship between needle phobia and dental anxiety

    NARCIS (Netherlands)

    Majstorovic, M.; Veerkamp, J.S.J.

    2004-01-01

    Purpose: This cross-sectional study aimed to explain the nature of needle phobia and its relationship in dental phobic children with evidence on age-related differences. Methods: The study used 2,865 patients (52% boys, 48% girls), 4 to 11 years old (mean=7.18 years). The patient sample included

  17. Evaluation of Aircraft Wing-Tip Vortex Using PIV

    Science.gov (United States)

    Alsayed, Omer A.; Asrar, Waqar; Omar, Ashraf A.

    2010-06-01

    The formation and development of a wing-tip vortex in a near and extended near filed were studied experimentally. Particle image velocimetry was used in a wind tunnel to measure the tip vortex velocity field and hence investigate the flow structure in a wake of aircraft half-wing model. The purpose of this investigation is to evaluate the main features of the lift generated vortices in order to find ways to alleviate hazardous wake vortex encounters for follower airplanes during start and approach such that the increase in airport capacity can be achieved. First the wake structure at successive downstream planes crosswise to the axis of the wake vortices was investigated by measuring parameters such as core radius, maximum tangential velocities, vorticities and circulation distributions. The effect of different angles of attack setting on vortex parameters was examined at one downstream location. In very early stages the vortex sheet evolution makes the tip vortex to move inward and to the suction side of the wing. While the core radius and circulation distributions hardly vary with the downstream distance, noticeable differences for the same vortex parameters at different angles of attack settings were observed. The center of the wing tip vortices scatter in a circle of radius nearly equal to 1% of the mean wing chord and wandering amplitudes shows no direct dependence on the vortex strength but linearly increase with the downstream distance.

  18. Turbine Blade Tip-Gap Flow Physics and Control

    Science.gov (United States)

    Douville, Travis

    2005-11-01

    A linear cascade that is designed to simulate the flow around blades in the low-pressure turbine stage of turbo-jet engines is used to study the physics of the tip-gap flow and vortex. The cascade consists of three Pratt & Whitney ``PakB'' blades. The experiment investigated gap sizes of 0.5 to 5.0 percent of the blade axial chord, and Reynolds numbers from 100K to 500K that correspond to tip relative Mach numbers of 0.04 to 0.21. Static pressure ports at mid and tip spanwise locations recorded blade pressure distributions. Static end wall taps recorded pressures in the gap region. A five-hole Pitot probe that was traversed in the blade wakes was used to determine total pressure loss coefficients and local velocity vectors. Baseline measurements were analyzed across the range of Reynolds numbers and gap sizes to categorize their effects. These were then compared to flow changes produced by a passive flow control device placed at the end of a blade to locally reduce the gap height. Its effect on the tip-gap flow is presented.

  19. Role of ultrasound for central catheter tip localization in neonates: a review of the current evidence.

    Science.gov (United States)

    Sharma, Deepak; Farahbakhsh, Nazanin; Tabatabaii, Seyyed Ahmad

    2018-02-15

    Central catheters are known as "life lines" in intensive care units and are used frequently in neonatal intensive care unit (NICU) for multiple indications. The central catheters used in NICU includes umbilical venous catheter (UVC), umbilical arterial catheter (UAC) and peripherally inserted central catheter (PICC) lines. The tip of these central lines needs to be in a correct position as malpositioned central line tips lead to many neonatal complications. Radiograph either abdomen or chest is the most widely used modality for locating the tip of the central catheter. There are many disadvantages of radiographic confirmation of tip position and recently ultrasound (USG)/echocardiography has been used for localization of catheter tip. USG provides real-time assessment of the tip position with other added advantages like no radiation exposure, need for minimal training for performing USG, minimal handling of the neonate, identification of migration of central lines and making repositioning of central lines under USG guidance. The present evidence supports the use of USG/Echo for localization of central catheter tip and USG has shown to have good sensitivity, specificity, positive predictive value and negative predictive value when compared with a radiograph. In this review, we discuss about the role of USG/Echo in the identification of tip of central catheters in neonatal care.

  20. Intracranially Retained Sewing Needle in a Child: Does the Rust on the Needle Have any Implication?

    Science.gov (United States)

    Balak, Naci; Güçlü, Güçlühan; Karaca, Ismail; Aksoy, Sema

    2008-04-01

    A penetrating injury with a sewing needle is a rare phenomenon. The pathophysiological mechanism of late epilepsy after penetrating injuries is not clear. A 10-year-old female child had a seizure. An X-ray study of the skull and the cranial computed tomography scans showed a foreign object retained in the skull cavity. She was intact on neurological examination. Electroencephalogram (EEG) showed that there was bioelectrical disorganization in both hemispheres, being more prominent on the left side. A right posterior frontal median craniotomy was performed in order not to retract the left hemisphere within the interhemispheric fissure and the sewing needle was removed successfully. The sewing needle was rusted. The reason for the patient's seizure, 10 years after the injury, may be the corrosion of the sewing needle and rust formation in this case.

  1. 21 CFR 868.5150 - Anesthesia conduction needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient to...

  2. 21 CFR 884.6100 - Assisted reproduction needles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in in...

  3. Exploring needle anxiety among students attending a Nigerian ...

    African Journals Online (AJOL)

    Needle anxiety, a form of specific phobia refers to an intense fear of needles used for various medical procedures. It may result in the avoidance of such needle-involving procedures like intramuscular injections or vaccinations. About 4-8% of children and adolescents are said to generally suffer some form of anxiety.

  4. Diversity and identification of fungi associated with needles of Pinus ...

    African Journals Online (AJOL)

    Diversity and identification of fungi associated with needles of Pinus radiata in Tasmania. ... Previous studies of P. radiata have been based on fungal isolation and not direct PCR detection from needles. This research was a component ... Keywords: endophyte, environmental PCR, fungal isolation, MOTU, needle fungi, OTU ...

  5. Hollow needle used to cut metal honeycomb structures

    Science.gov (United States)

    Gregg, E. A.

    1966-01-01

    Hollow needle tool cuts metal honeycomb structures without damaging adjacent material. The hollow needle combines an electrostatic discharge and a stream of oxygen at a common point to effect rapid, accurate metal cutting. The tool design can be varied to use the hollow needle principle for cutting a variety of shapes.

  6. Percutaneous core needle biopsies: The yield in spinal tuberculosis ...

    African Journals Online (AJOL)

    Background. Current recommendations for spinal tuberculosis (TB) not requiring open surgery include core needle biopsy to confirm TB and determine drug sensitivity. International figures show the positive culture yield from core needle biopsies is 50 - 83%. Objectives. To (i) assess the yield of percutaneous needle ...

  7. Windows 8 visual quick tips

    CERN Document Server

    McFedries, Paul

    2012-01-01

    Easy-in, easy-out format covers all the bells and whistles of Windows 8 If you want to learn how to work smarter and faster in Microsoft's Windows 8 operating system, this easy-to-use, compact guide delivers the goods. Designed for visual learners, it features short explanations and full-color screen shots on almost every page, and it's packed with timesaving tips and helpful productivity tricks. From enhancing performance and managing digital content to setting up security and much more, this handy guide will help you get more out of Windows 8. Uses full-color screen shots and short, step-by-

  8. Twitter Tips, Tricks, and Tweets

    CERN Document Server

    McFedries, Paul

    2010-01-01

    Maximize your fun and boost your productivity with this updated, full-color guide to tantalizing Twitter tips!. The popularity of Twitter continues to soar, and is fast becoming the most popular social networking site online. Whether you're looking to learn how to set up an account for the first time or are on the prowl for some cool third-party Twitter apps, this full-color guide will boost your entire Twitter experience. Allowing you to communicate with fellow Twitters within a 140-character limit, this fun and fascinating social networking tool is easier than maintaining a blog and quicker

  9. Reduced variability and execution time to reach a target with a needle GPS system: Comparison between physicians, residents and nurse anaesthetists.

    Science.gov (United States)

    Fevre, Marie-Cécile; Vincent, Caroline; Picard, Julien; Vighetti, Arnaud; Chapuis, Claire; Detavernier, Maxime; Allenet, Benoît; Payen, Jean-François; Bosson, Jean-Luc; Albaladejo, Pierre

    2018-02-01

    Ultrasound (US) guided needle positioning is safer than anatomical landmark techniques for central venous access. Hand-eye coordination and execution time depend on the professional's ability, previous training and personal skills. Needle guidance positioning systems (GPS) may theoretically reduce execution time and facilitate needle positioning in specific targets, thus improving patient comfort and safety. Three groups of healthcare professionals (41 anaesthesiologists and intensivists, 41 residents in anaesthesiology and intensive care, 39 nurse anaesthetists) were included and required to perform 3 tasks (positioning the tip of a needle in three different targets in a silicon phantom) by using successively a conventional US-guided needle positioning and a needle GPS. We measured execution times to perform the tasks, hand-eye coordination and the number of repositioning occurrences or errors in handling the needle or the probe. Without the GPS system, we observed a significant inter-individual difference for execution time (PGPS attenuated the inter-individual and group variability. We observed a reduced execution time and improved hand-eye coordination in all groups as compared to US without GPS. Neither US training, video gaming nor demographic personal or professional factors were found to be significantly associated with reduced execution time when GPS was used. US associated with GPS systems may improve safety and decrease execution time by reducing inter-individual variability between professionals for needle-handling procedures. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  10. Physical Properties Of Acupuncture Needles: Do Disposable Acupuncture Needles Break With Normal Use

    Science.gov (United States)

    2016-06-01

    Lamb shank, which has complexity of tendon, fascia, and bone , was used to mimic human tissue. The needles (n=10) were stressed in the tissue substitute...Synthetic tissues have been used in other studies11 but are too simplistic and do not mimic human tissue since they do not have muscle, fascia or bone ...They also deposit a sticky , oily residue on the acupuncture needles that is difficult to remove before viewing under a microscope11. Due to lack

  11. Rebleeding rates following TIPS for variceal hemorrhage in the Viatorr era: TIPS alone versus TIPS with variceal embolization.

    Science.gov (United States)

    Gaba, Ron C; Bui, James T; Cotler, Scott J; Kallwitz, Eric R; Mengin, Olga T; Martinez, Brandon K; Berkes, Jaime L; Carrillo, Tami C; Knuttinen, M Grace; Owens, Charles A

    2010-08-06

    To compare rebleeding rates following treatment of variceal hemorrhage with TIPS alone versus TIPS with variceal embolization in the covered stent-graft era. In this retrospective study, 52 patients (M:F 29:23, median age 52 years) with hepatic cirrhosis and variceal hemorrhage underwent TIPS insertion between 2003 and 2008. Median Child-Pugh and MELD scores were 8.5 and 13.5. Generally, 10-mm diameter TIPS were created using covered stent-grafts (Viatorr; W.L. Gore and Associates, Flagstaff, AZ). A total of 37 patients underwent TIPS alone, while 15 patients underwent TIPS with variceal embolization. The rates of rebleeding and survival were compared. All TIPS were technically successful. Median portosystemic pressure gradient reductions were 13 versus 11 mmHg in the embolization and non-embolization groups. There were no statistically significant differences in Child-Pugh and MELD score, or portosystemic pressure gradients between each group. A trend toward increased rebleeding was present in the non-embolization group, where 8/37 (21.6%) patients rebled while 1/15 (6.7%) patients in the TIPS with embolization group rebled (P = 0.159) during median follow-up periods of 199 and 252 days (P = 0.374). Rebleeding approached statistical significance among patients with acute hemorrhage, where 8/32 (25%) versus 0/14 (0%) rebled in the non-embolization and embolization groups (P = 0.055). A trend toward increased bleeding-related mortality was seen in the non-embolization group (P = 0.120). TIPS alone showed a high incidence of rebleeding in this series, whereas TIPS with variceal embolization resulted in reduced recurrent hemorrhage. The efficacy of embolization during TIPS performed for variceal hemorrhage versus TIPS alone should be further compared with larger prospective randomized trials.

  12. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  13. Simulation of CNT-AFM tip based on finite element analysis for targeted probe of the biological cell

    Energy Technology Data Exchange (ETDEWEB)

    Yousefi, Amin Termeh, E-mail: at.tyousefi@gmail.com; Miyake, Mikio, E-mail: miyakejaist@gmail.com; Ikeda, Shoichiro, E-mail: sho16.ikeda@gmail.com [ChECA IKohza, Dept. Environmental & Green Technology (EGT), Malaysia, Japan International Institute of Technology (MJIIT), University Technology Malaysia - UTM, Kualalumpur (Malaysia); Mahmood, Mohamad Rusop, E-mail: nano@uitm.gmail.com [NANO-SciTech Centre, Institute of Science, Universiti Teknologi MARA (UiTM), Shah Alam, Selangor (Malaysia)

    2016-07-06

    Carbon nanotubes (CNTs) are potentially ideal tips for atomic force microscopy (AFM) due to the robust mechanical properties, nano scale diameter and also their ability to be functionalized by chemical and biological components at the tip ends. This contribution develops the idea of using CNTs as an AFM tip in computational analysis of the biological cell’s. Finite element analysis employed for each section and displacement of the nodes located in the contact area was monitored by using an output database (ODB). This reliable integration of CNT-AFM tip process provides a new class of high performance nanoprobes for single biological cell analysis.

  14. Influence of hypodermic needle dimensions on subcutaneous injection delivery - a pig study of injection deposition evaluated by CT scanning, histology, and backflow

    DEFF Research Database (Denmark)

    Ann Praestmark Juul, Kezia; Bengtsson, Henrik; Eyving, Bente

    2012-01-01

    BACKGROUND: Thinner and shorter needles for subcutaneous administration are continuously developed. Previous studies have shown that a thinner needle causes fewer occurrences of painful needle insertions and that a shorter needle decreases the occurrence of painful intramuscular injections. However......, little is known about local drug delivery in relation to needle length and thickness. This study aimed to compare deposition depth and backflow from three hypodermic needles of 3 mm 34G (0.19 mm), 5 mm 32G (0.23 mm), and 8 mm 30G (0.30 mm) in length and thickness. METHODS: Ex vivo experiments were...... depth, the bulk of the injection was in the subcutaneous tissue and did not propagate from subcutis into dermis. With the 8 mm 30G needle all injections apart from one intramuscular injection were located in the subcutaneous layer. The volume depositions peaked in 4-5 mm depth for the 3 mm 34G needle...

  15. Use of optimized ultrasound axis along with marked introducer needle to prevent mechanical complications of internal jugular vein catheterization

    Directory of Open Access Journals (Sweden)

    Tanmoy Ghatak

    2013-01-01

    Full Text Available Internal jugular vein (IJV catheterization is a routine technique in the intensive care unit. Ultrasound (US guided central venous catheter (CVC insertion is now the recommended standard. However, mechanical complications still occur due to non-visualization of the introducer needle tip during US guidance. This may result in arterial or posterior venous wall puncture or pneumothorax. We describe a new technique of (IJV catheterization using US, initially the depth of the IJV from the skin is measured in short-axis and then using real time US long-axis view guidance a marked introducer needle is advanced towards the IJV to the defined depth measured earlier in the short axis and the IJV is identified, assessed and cannulated for the CVC insertion. Our technique is simple and may reduce mechanical complications of US guided CVC insertion.

  16. Measuring Fan-Blade-Tip Displacements

    Science.gov (United States)

    Berry, Robert F., Jr.

    1988-01-01

    Magnets and Hall-effect transducers used to monitor tip-to-shroud clearances. Mounting permanent magnet in end of fan blade and monitoring tip-to-shroud distance by use of output of Hall-effect transducers affixed to surface of shroud. Transducers provide real-time information. By placing magnets in each fan-blade tip, complete set monitored sequentially as each blade rotates past sensor. Application in many rotating machines, providing surrounding materials nonmagnetic and temperatures not severe.

  17. Dual mode fuel injector with one piece needle valve member

    Science.gov (United States)

    Lawrence, Keith E.; Hinrichsen, Michael H.; Buckman, Colby

    2005-01-18

    A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively by inner and outer needle value members. The homogenous charged nozzle outlet set is defined by an outer needle value member that is moveably positioned in an injector body, which defines the conventional nozzle outlet set. The inner needle valve member is positioned in the outer needle valve member. The outer needle valve member is a piece component that includes at least one external guide surface, an external value surface and an internal valve seat.

  18. NUTRIENTS CONCENTRATION AND RETRANSLOCATION IN THE Pinus taeda L. NEEDLES

    Directory of Open Access Journals (Sweden)

    Márcio Viera

    2010-03-01

    Full Text Available Aiming at evaluating nutrients concentration and retranslocation in the Pinus taeda L. needles, this study was developed in two stands, in native grass area and in second rotation area, with same species and same age (7.5 years old in Cambará do Sul, RS. The needles were collected in plants in four orthogonal points (South, North, East and West, sampled new needles, mature needles and old needles. The material was dried in a stove, milled and chemically analyzed (macro and micronutrients. The concentrations of N, P, K, B, Cu and Zn had decreased, of Ca, Fe and Mn increased, and the Mg and S have remained constant with the age of the needles. The retranslocation rate (old-new needles was more than 50% for most nutrients, except for Mn and Fe, showed that cumulative effect and the Ca reference element.

  19. Needle phobia: etiology, adverse consequences, and patient management.

    Science.gov (United States)

    Sokolowski, Chester J; Giovannitti, Joseph A; Boynes, Sean G

    2010-10-01

    Needle phobia has profound health, dental, societal, and legal implications, and severe psychological, social, and physiologic consequences. There is genetic evidence for the physiologic response to needle puncture, and a significant familial psychological component, showing evidence of inheritance. Needle phobia is also a learned behavior. The dental practitioner must recognize patients with needle phobia before the administration of local anesthetics to identify patients who are potentially reactive and to prevent untoward sequelae. Needle phobia is highly associated with avoidance behavior, and the dentist must exhibit compassion and respect. To avoid bradycardia, hypotension, unconsciousness, convulsions, and possibly asystole, oral premedication with benzodiazepines or other antianxiety agents must be considered for patients who are needle phobic. Management of needle phobiaeinduced syncope includes perioperative monitoring, oxygen administration, positioning, atropine, and vasopressors. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Needle position analysis in cases of paralysis from transforaminal epidurals: consider alternative approaches to traditional technique.

    Science.gov (United States)

    Atluri, Sairam; Glaser, Scott E; Shah, Rinoo V; Sudarshan, Gururau

    2013-01-01

    Transforaminal technique for epidural steroid injections, unlike other approaches, is uniquely associated with permanent, bilateral, lower extremity paralysis. To review the literature and analyze the reported cases of paralysis from lumbar transforaminal epidural steroid injections to possibly establish a cause and to prevent this complication. Eighteen cases of paralysis from transforaminal epidural injection have been reported. We could analyze the position of the needle within the neural foramen based on the available images and/or description among 10 of these 18 cases. Five cases were performed with computed tomography guidance and 12 cases were performed with fluoroscopic guidance [unknown in one case]. Additionally, other variables associated with the procedure, including the technique, were also examined. Analysis of the needle position in the neural foramen in cases of paralysis from transforaminal epidural steroid injections. This analysis is based on images and/or description provided in published reports. Paralysis in these cases seems to be associated with a well performed traditional safe triangle approach with good epidural contrast spreads. Analyzed data shows that 77.7% of the time, the needle was in the superior part of the foramen. In 71.4% of the cases, the needle was in the anterior part of the foramen. This coincides with the location of the radicular artery in the foramen. In 22.2%, the needle was in the midzone (neither in the superior nor inferior zone). No level was spared as this event occurred at every foramen from T12 to S1. Ten of these events happened during a left-sided procedure and 8 during a right-sided procedure. No relation to this complication was noted when other variables like type and size of the needles, side of the injection, local anesthetic, contrast, or volume of injectate were taken into consideration. Only 18 cases of paralysis from transforaminal epidurals have been reported. Out of these, only 10 cases included

  1. Thermomechanical characterization of one-way shape memory Nitinol as an actuator for active surgical needle

    Science.gov (United States)

    Honarvar, Mohammad

    Needle-based intervention insertion is one of the common surgical techniques used in many diagnostic and therapeutic percutaneous procedures. The success of such procedures highly depends on the accuracy of needle placement at target locations. An active needle has the potential to enhance the accuracy of needle placement as well as to improve clinical outcome. Bending forces provided by the attached actuators can assist the maneuverability in order to reach the targets following a desired trajectory. There are three major research parts in the development of active needle project in the Composites Laboratory of Temple University. They are thermomechanical characterization of shape memory alloy (SMA) or Nitinol as an actuator for smart needle, mechanical modeling and design of smart needles, and study of tissue needle interaction. The characterization of SMA is the focus of this dissertation. Unique thermomechanical properties of Nitinol known as shape memory effect and superelasticity make it applicable for different fields such as biomedical, structural and aerospace engineering. These unique behaviors are due to the comparatively large amount of recoverable strain which is being produced in a martensitic phase transformation. However, under certain ranges of stresses and temperatures, Nitinol wires exhibit unrecovered strain (also known as residual strain); which limits their applicability. Therefore, for applications that rely on the strain response in repetitive loading and unloading cycles, it is important to understand the generation of the unrecovered strain in the Nitinol wires. In this study, the unrecovered strain of Nitinol wires with various diameters was investigated, using two experimental approaches: constant stress and uniaxial tensile tests. Moreover, a critical range of stress was found beyond which the unrecovered strain was negligible at temperatures of 70 to 80°C depending on the wire diameter. Wire diameters varied from 0.10 to 0.29 mm were

  2. C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Leschka, Simon C.; Shikh, Samer El; Wossmann, Christine; Schumacher, Martin; Taschner, Christian A. [University Hospital Freiburg, Department of Neuroradiology, Neurocentre, Freiburg (Germany); Babic, Drazenko [Philips Medical Systems, Best (Netherlands)

    2012-03-15

    The aim of this study is to report our early clinical experience using C-arm cone beam computed tomography with fluoroscopic overlay for image guidance during percutaneous needle procedures of the spine and pelvis. Twelve consecutive patients (four female and eight male patients; mean age, 64 years; range, 47-74 years; SD {+-} 7.6 years) who underwent percutaneous biopsy of the spine and pelvis for suspected metastasis (n = 12), spondylodiscitis (n=6), abscess (n=5) or bone tumour (n = 1) were prospectively included between March 2009 and November 2010. The procedures were performed on the Allura Xper FD20/20 (Philips, Best, the Netherlands) using cone beam computed tomography (XperCT) with the C-arm combined with fluoroscopic overlay for needle guidance. Based on an initial XperCT, entry and target points were defined using dedicated guidance software (XperGuide). The needle path was visualised in various reconstructed planes and could be adjusted when considered necessary. For percutaneous interventions, the entry view (overlay of entry and target point in the bull's eye fashion), the progression view (perpendicular to the entry view) as well as two additional views could automatically be piloted to with the C-arm system. Needle navigation was supported by a biopsy guidance device (Seestar, Radi, Uppsala, Sweden). Correct needle positioning was confirmed with a second XperCT acquisition. Technical success was defined as any target point reached via the planned needle trajectory with a distance of final needle tip within 5 mm of the planned target point in any direction. In all 12 patients, target areas could be defined based on XperCT data. In 11 of 12 (92%) cases, the target point was successfully reached on the planned trajectory with a mean error of 2.8 mm (range, 0.5-9.4 mm; SD, 2.4 mm). No peri- or post-interventional complications occurred. XperCT-guided interventions with the XperGuide system seem a safe and reliable tool for percutaneous needle

  3. Usefulness of CT-guided trans-bronchial needle aspiration biopsy for mediastinal lymph nodes

    International Nuclear Information System (INIS)

    Cui Bing; Rong Fu

    2001-01-01

    Objective: To determine the nature of enlarged mediastinal lymph nodes, the study of CT-guided trans-bronchial needle aspiration biopsy (CT-TBNA) was conducted. Methods: According to classification and locating standard of mediastinal lymph nodes, CT-TBNA was performed in 158 mediastinal lymph nodes of 73 patients, including 54 primary lung cancer with enlarged mediastinal lymph nodes, 5 malignant lymphoma, 3 mediastinal abscess and 11 mediastinal inflammatory adenopathy. Results: CT confirmed that the needles were inside all 158 lymph nodes. Adequate aspirates for histologic and/or cytologic diagnosis were obtained in 136 of 158(86%) lymph node biopsies. No serious complications occurred. Conclusion: Locating standard of CT-guided TBNA was reliable. Puncture was safe and cost-effective. CT-TBNA was important for ascertaining the nature of mediastinal adenopathy and staging of neoplasms

  4. Practical guidelines for ultrasound-guided core needle biopsy of soft-tissue lesions: Transformation from beginner to specialist

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Yoon; Chung, Hye Won; Oh, Tack Sun; Lee, Jong Seok [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasound-guided core needle biopsy (US-CNB) is an important step in the diagnosis of musculoskeletal soft-tissue lesions. To maximize efficacy and minimize the complications of US-CNB, it is critical to collaborate with a multidisciplinary team and to understand the particular considerations of US-CNB for these lesions. The purpose of this article is to provide a systematic review and step-by-step tips for using US-CNB to diagnose musculoskeletal soft-tissue lesions.

  5. The tip of the iceberg

    DEFF Research Database (Denmark)

    Bjørst, Lill Rastad

    2010-01-01

      Abstract: The tip of the iceberg: Ice as a nonhuman actor of the climate change debate   The global climate change debate has the Arctic as a core region of concern and ice has become a central aspect of discourses. This article discusses ice representations from six different contexts linked...... to the 2009 United Nations Climate Change Conference (COP15) in Copenhagen. The author argues that even though the discussions often seem to be centred on ice alone, the latter gets inscribed in narratives and metaphors which have wider implications for how the Arctic and its Indigenous peoples...... are represented. Ice becomes a nonhuman actor, framing the discussions, acting in specific ways, and linking hybrid networks. Indeed it is used in diverse platforms by scientists, politicians, governments, NGOs, as well as Inuit hunters and fishermen...

  6. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  7. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    DEFF Research Database (Denmark)

    Shin, K. W.; Andersen, Poul

    2015-01-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached...

  8. A plasma needle generates nitric oxide

    International Nuclear Information System (INIS)

    Stoffels, E; Gonzalvo, Y Aranda; Whitmore, T D; Seymour, D L; Rees, J A

    2006-01-01

    Generation of nitric oxide (NO) by a plasma needle is studied by means of mass spectrometry. The plasma needle is an atmospheric glow generated by a radio-frequency excitation in a mixture of helium and air. This source is used for the treatment of living tissues, and nitric oxide may be one of the most important active agents in plasma therapy. Efficient NO generation is of particular importance in the treatment of cardiovascular diseases. Mass spectrometric measurements have been performed under various plasma conditions; gas composition in the plasma and conversion of feed gases (nitrogen and oxygen) into other species has been studied. Up to 30% of the N 2 and O 2 input is consumed in the discharge, and NO has been identified as the main conversion product

  9. A simultaneous comparison of acupuncture needle and insulated needle sphenoidal electrodes for detection of anterior temporal spikes.

    Science.gov (United States)

    Chu, N S

    1992-01-01

    Uninsulated acupuncture needles have been used as sphenoidal electrodes, but the issue of insulation has not been adequately addressed. In this report, acupuncture needles and insulated needle sphenoidal electrodes were simultaneously used to compare the rate of spike detection, spike amplitude and distribution of maximal spikes from eight spike foci in seven patients with temporal lobe epilepsy. When compared to the insulated needle electrode, the acupuncture needle electrode was equally effective in spike detection, but spike amplitudes tended to be smaller and maximal spikes were less frequently encountered. Thus, insulation has an influence on the spikes recorded by the acupuncture needle sphenoidal electrode. However, the overall effect appears to be not sufficiently different from the insulated needle electrode for the purpose of detecting anterior temporal spikes in outpatient EEG recordings for the diagnosis of temporal lobe epilepsy.

  10. Chemical immobilization of free-ranging fallow deer (Dama dama): effect of needle length on induction time.

    Science.gov (United States)

    Bergvall, Ulrika A; Kjellander, Petter; Ahlqvist, Per; Johansson, Örjan; Sköld, Kent; Arnemo, Jon M

    2015-04-01

    We evaluated impact of the needle length, sex, and body condition on chemical immobilization induction time in 50 (29 males and 21 females) free-ranging fallow deer (Dama dama) in Sweden, 2006-11. Induction time is probably the single most important factor when immobilizing free-ranging wildlife with the use of a remote drug-delivery system. Induction times should be short to minimize stress and risk of injury, and to ensure that immobilized animals can be found and clinically monitored as soon as possible. We measured the distance between the darting location and where we recovered the immobilized animal and also the time occurring between the two events. We used two types of needles: 2.0 × 30- or 2.0 × 40-mm barbed needles with side ports. The most important result is that a 10-mm-longer dart needle can reduce the retrieval time substantially (>20 min) until an animal is under monitoring. On average after the darting, the retrieval time decreased from 51 to 29 min and the distance decreased from 519 m from the darting location to 294 m. We suggest that a needle length of 40 mm is preferable for immobilization of wild fallow deer, especially for animals in over-average-to-fat body condition.

  11. A retractable barb needle for drug darts

    Directory of Open Access Journals (Sweden)

    G.L. van Rooyen

    1973-07-01

    Full Text Available The mechanism and action of a new retractable barbneedle for drug darts are described. This dart needle is particularly successful in obviating unnecessary flight reactions andtrauma in darted animals, and facilitates the complete injection of the drug dose before the barb is retracted and the dart is dislogded from the animal. The whole process is completed within a few seconds and the expended dart can usually be retrieved in the immediate vicinity where the animal was darted.

  12. Biomechanical simulation of needle insertion into cornea based on distortion energy failure criterion.

    Science.gov (United States)

    Su, Peng; Yang, Yang; Zhang, Leiyu; Huang, Long

    2016-01-01

    This paper is mainly about biomechanical behavior of needle insertion into cornea, and proposes a failure criterion to simulate the insertion process which has attracted considerable attention due to its importance for the minimally invasive treatment. In the process of needle insertion into cornea, tiny and complex insertion force is generated due to contact between needle and soft tissue. Based on the distortion energy theory, there is proposed a failure criterion of corneal material that can solve contact problem between rigid body and biological tissue in insertion simulation, where Cauchy stress of corneal material is the key to numerical calculation. A finite element model of in vivo cornea is built, and the cornea constrained by sclera is simplified to two layers containing epithelium and stroma. Considering the hyper-viscoelastic property of corneal material, insertion simulation is carried out. By insertion experiment, the insertion force increases with insertion depth accompanying obvious fluctuations. Different insertion forces are generated at different speeds. The punctured locations are obvious in the force-displacement curves. The results of insertion simulation are generally consistent with experimental data. Maps of von Mises stress reflect the tissue injury of the cornea during insertion process, and punctured status corresponds to the point in the curves. The ability of this study to reproduce the behavior of needle insertion into cornea opens a promising perspective for the control of robotic surgery operation as well as the real-time simulation of corneal suture surgery.

  13. Transthoracic fine needle aspiration biopsy of subcarinal lesion: oblique approach using biplane fluoroscopic guidance

    International Nuclear Information System (INIS)

    Kim, Sung Tae; Jeon, Seok Chol; Choi, Yo Won; Seo, Heung Suk; Hahm, Chang Kok

    1995-01-01

    To evaluate effectiveness of oblique approach under biplane fluoroscopic guidance in transthoracic fine needle aspiration biopsy. Fourteen consecutive patients underwent transthoracic fine needle aspiration biopsy for subcarinal lesions. Subcarina was the only accessible biopsy site in 13 patients. Subcarinal biopsy was performed to determine the presence of metastasis in an enlarged subcarinal lymph node in the remaining one patient. Before biopsy, we evaluated the size and location of the lesion on preliminary plain chest X-ray film and CT scan. Under dual projection fluoroscopic guidance, biopsy was performed through right posterior intercostal space with the patient prone by using oblique approach. On 15 degree LAO projection the needle was directed to the area anterior to the spine and advanced to the line extending through the posterior wall of the main bronchus. Cytologic diagnosis was made in 12 out of 14 patients(accuracy 85.7%). The final diagnosis consisted of 5 squamous cell carcinoma, 5 small cell carcinoma, 1 adenocarcinoma and 1 adenosquamous carcinoma. Pneumothorax developed in 2 patients(14%) and was managed by chest tube drainage. Mild hemoptysis was observed in 2. Transthoracic fine needle aspiration biopsy using oblique approach under biplane fluoroscopic guidance is a relatively safe and sensitive method for the histologic diagnosis of subcarinal lesion

  14. A novel needle-type sampling device for flexible ultrathin bronchoscopy.

    Science.gov (United States)

    Suda, Yuji; Tanaka, Akiko; Hayashi, Katsutoshi; Shindoh, Yuriko; Iijima, Hideya

    2008-09-01

    Diagnosis of suspected cancer in the periphery of the lung is difficult. A flexible ultrathin bronchoscope has been developed for the diagnosis of peripherally located pulmonary lesions that cannot be reached with the sampling devices for standard flexible bronchoscopes. The diagnostic yield with forceps and a brush for ultrathin bronchoscopes, however, is not adequate, especially when a lesion is not exposed to the bronchial lumen. We have thus developed a novel needle-type sampling device and tested its yield in transbronchial cytology. The device consists of an elongated dental H-file (0.4 mm in diameter and 110 cm in length), a housing sheath (1.0 mm in outer diameter), and a novel handle, which enables rapid out-and-in motion of the needle. Ten consecutive patients with a peripheral pulmonary lesion who had an indication for diagnostic procedure with a flexible ultrathin bronchoscope were enrolled. The optimal bronchial route to the lesion was analyzed with virtual bronchoscopy in a data set obtained with high-resolution computed tomography, and a novel bronchial route labeling system (prior-ridge-based relative orientation nomenclature) was employed to guide insertion of the bronchoscope. Sampling with the novel needle was performed prior to use of the forceps and brush under conventional fluoroscopy. In all the cases, sampling with the needle was successful and the amount of the specimen was sufficient for cytology. Our novel sampling system with flexible ultrathin bronchoscopes may contribute to accurate and minimally invasive diagnosis of peripheral pulmonary lesions.

  15. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  16. Liver abscess due to sewing needle perforation.

    Science.gov (United States)

    Jutte, Ewoud; Cense, Huib

    2010-08-03

    A 45-year-old female was admitted to the hospital with a 1-week history of right upper abdominal pain and nausea. Ultrasonography showed a thickened duodenum with infiltration. Subsequent gastroscopy did not reveal any abnormalities. CT scan showed a foreign body perforation at the duodenum and a liver abscess (Fig. 1A,B). A diagnostic laparoscopy was performed. During the operation, the abscess was drained (Fig. 2A,B) and a sewing needle was removed (Fig. 3A,B). The patient claimed to have no recollection of swallowing the needle and made a quick recovery. Although rare, gastrointestinal perforations due to ingested foreign bodies most frequently occur at ileocecal, rectosigmoid, and duodenal regions[1]. Sewing needle perforations into the liver have been reported in children, adults, and psychiatric cases. Symptoms can vary from mild gastric pain to signs of peritonitis[2]. "Wait and see" is recommended for asymptomatic patients with no complications. Symptomatic patients (e.g., liver abscess) need surgical intervention[1,2,3].

  17. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  18. Twelve Tips for Effective Electronic Presentation.

    Science.gov (United States)

    Crosby, Joy

    1994-01-01

    Offers 12 tips for effective electronic presentation. This article is intended for readers who may be considering using electronic presentation for the first time. Offers reasons for its popularity and occasions when it may be used. The tips offer assistance in the design and presentation of electronic material. (LZ)

  19. Economics of tipping the climate dominoes

    Science.gov (United States)

    Lemoine, Derek; Traeger, Christian P.

    2016-05-01

    Greenhouse gas emissions can trigger irreversible regime shifts in the climate system, known as tipping points. Multiple tipping points affect each other’s probability of occurrence, potentially causing a `domino effect’. We analyse climate policy in the presence of a potential domino effect. We incorporate three different tipping points occurring at unknown thresholds into an integrated climate-economy model. The optimal emission policy considers all possible thresholds and the resulting interactions between tipping points, economic activity, and policy responses into the indefinite future. We quantify the cost of delaying optimal emission controls in the presence of uncertain tipping points and also the benefit of detecting when individual tipping points have been triggered. We show that the presence of these tipping points nearly doubles today’s optimal carbon tax and reduces peak warming along the optimal path by approximately 1 °C. The presence of these tipping points increases the cost of delaying optimal policy until mid-century by nearly 150%.

  20. Operating needle exchange programmes in the hills of Thailand.

    Science.gov (United States)

    Gray, J

    1995-01-01

    Injecting drug use is increasingly markedly amongst the ethnically distinct Hilltribe peoples of northern Thailand in the notorious 'Golden Triangle'. This paper reports on the establishing of needle exchanges in three remote Hilltribe villages, examining the success and the failure. Up to 60% of adult males and a smaller percentage of adult females in these villages are habitual users of opium and/or heroin. Overcoming initial concern that needle distribution would encourage increased use, the villagers themselves have assumed responsibility for much of the needle exchange operation. Prior to the introduction of the needle exchanges all the injecting drug users were sharing needles. This behaviour changed significantly with the introduction of the exchanges. Reluctance on the part of locally-based government officials to participate fully in the programme created difficulties in maintaining needle supplies which saw some resumption in needle sharing. HIV seroprevalence rates amongst the tested injecting drug users remained fairly stable at 33% in February 1993 and 32% in February 1994. The conclusion can be drawn that needle exchange programmes are operable in the Hilltribe context and that they are the best means of limiting HIV/AIDS transmission amongst injecting drug users and the wider community. The success of needle exchange programmes, however, is dependent upon co-operation from various government agencies and non-government agencies, in addition to the local communities. To this end mechanisms ensuring co-operation, training, monitoring and evaluation need to be developed alongside the introduction of needle exchanges.

  1. Tendon needling for treatment of tendinopathy: A systematic review.

    Science.gov (United States)

    Krey, David; Borchers, James; McCamey, Kendra

    2015-02-01

    To summarize the best available evidence to determine if tendon needling is an effective treatment for tendinopathy. Data source. Medline and Cochrane Databases through November 2013. Utilizing the search terms tendinopathy, needle, needling, tenotomy, dry needling, needling tendon, needle fenestration, and tendon fenestration, 17 articles were identified through our systematic literature search. Of these, 4 studies met the inclusion criteria. Four independent reviewers reviewed the articles. The study results and generated conclusions were agreed upon. The studies that were included in this review suggest that tendon needling improves patient reported outcomes in patients with tendinopathy. In 2 studies evaluating tendon needling in lateral epicondylosis, one showed an improvement in a subjective visual analogue scale score of 34% (significant change > 25%) from baseline at 6 months. The other showed an improvement of 56.1% in a visual analogue scale score from baseline. In 1 study evaluating tendon needling in addition to eccentric therapy for Achilles tendinosis, the subjective Victorian Institute of Sport Assessment-Achilles (VISA-A) score improved by 19.9 (significant change > 10) (95% CI, 13.6-26.2) from baseline. In 1 study evaluating tendon needling in rotator cuff tendinosis, the subjective shoulder pain and disability index showed statistical significant improvement from baseline at 6 months (P tendinopathy. There is a trend that shows that the addition of autologous blood products may further improve theses outcomes.

  2. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  3. Nanobits - exchangable and customisable scanning probe tips

    DEFF Research Database (Denmark)

    Yildiz, Izzet

    Invention of atomic force microscopy (AFM) pioneered a novel aspect for the surface metrology concept. A range of scanning probe methods have been developed over the years based on different sorts of tip-surface interaction: electrical, optical, thermal, force. Reproducible and fast fabrication...... miniaturisation requires the scanning probes to adapt into finer geometries to provide higher lateral resolution. To meet these needs critical dimension AFM (CD-AFM) and deep trench AFM (DT-AFM) were invented, which use different types of AFM tips: high-aspect-ratio tips for DT-AFM and CD tips for CD...... replacement could greatly increase the efficiency and adaptability of a CD system. In this PhD study, NanoBits – nano-sized customisable and exchangeable scanning probe tips – were developed to meet the demands of current AFM applications. Two different methods were followed for the fabrication of Nano...

  4. Chemical composition of needles and cambial activity of stems of Scots pine trees affected by air pollutants in Polish forests

    Science.gov (United States)

    Wojciech Dmuchowski; Ewa U. Kurczynska; Wieslaw Wloch

    1998-01-01

    The impact of environmental pollution is defined for the chemical composition of Scots pine (Pinus sylvestris L.) needles and cambial activity in the tree stems in Polish forests. The research investigated 20-year-old trees growing in two areas in significantly different levels of pollution. The highly polluted area was located near the Warsaw...

  5. Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer

    Science.gov (United States)

    Chen, Ruimin; Tsui, Po-Hsiang; Zhou, Qifa; Humayun, Mark S; Shung, K Kirk

    2010-01-01

    A cataract is a clouding of the lens in the eye that affects vision. Phacoemulsification is the mostly common surgical method for treating cataracts, and determining that the optimal phacoemulsification energy is dependent on measuring the hardness of the lens. This study explored the use of an ultrasound needle transducer for invasive measurements of ultrasound attenuation coefficient to evaluate the hardness of the cataract lens. A 47 MHz high-frequency needle transducer with a diameter of 0.9 mm was fabricated by a polarized PMN-33%PT single crystal in the present study. The attenuation coefficients at different stages of an artificial porcine cataract lens were measured using the spectral shift approach. The hardness of the cataract lens was also evaluated by mechanical measurement of its elastic properties. The results demonstrated that the ultrasonic attenuation coefficient was increased from 0.048 ± 0.02 to 0.520 ± 0.06 dB mm−1 MHz−1 corresponding to an increase in Young’s modulus from 6 ± 0.4 to 96 ± 6.2 kPa as the cataract further developed. In order to evaluate the feasibility of combining needle transducer and phacoemulsification probe for real-time measurement during cataract surgery, the needle transducer was mounted on the phacoemulsification probe for a vibration test. The results indicated that there was no apparent damage to the tip of the needle transducer and the pulse–echo test showed that a good performance in sensitivity was maintained after the vibration test. PMID:19759408

  6. SU-F-J-10: Sliding Mode Control of a SMA Actuated Active Flexible Needle for Medical Procedures

    International Nuclear Information System (INIS)

    Podder, T

    2016-01-01

    Purpose: In medical interventional procedures such as brachytherapy, ablative therapies and biopsy precise steering and accurate placement of needles are very important for anatomical obstacle avoidance and accurate targeting. This study presents the efficacy of a sliding mode controller for Shape Memory Alloy (SMA) actuated flexible needle for medical procedures. Methods: Second order system dynamics of the SMA actuated active flexible needle was used for deriving the sliding mode control equations. Both proportional-integral-derivative (PID) and adaptive PID sliding mode control (APIDSMC) algorithms were developed and implemented. The flexible needle was attached at the end of a 6 DOF robotic system. Through LabView programming environment, the control commands were generated using the PID and APIDSMC algorithms. Experiments with artificial tissue mimicking phantom were performed to evaluate the performance of the controller. The actual needle tip position was obtained using an electromagnetic (EM) tracking sensor (Aurora, NDI, waterloo, Canada) at a sampling period of 1ms. During experiment, external disturbances were created applying force and thermal shock to investigate the robustness of the controllers. Results: The root mean square error (RMSE) values for APIDSMC and PID controllers were 0.75 mm and 0.92 mm, respectively, for sinusoidal reference input. In the presence of external disturbances, the APIDSMC controller showed much smoother and less overshooting response compared to that of the PID controller. Conclusion: Performance of the APIDSMC was superior to the PID controller. The APIDSMC was proved to be more effective controller in compensating the SMA uncertainties and external disturbances with clinically acceptable thresholds.

  7. Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer

    International Nuclear Information System (INIS)

    Huang, C.-C.; Chen Ruimin; Zhou Qifa; Shung, K Kirk; Tsui, P.-H.; Humayun, Mark S

    2009-01-01

    A cataract is a clouding of the lens in the eye that affects vision. Phacoemulsification is the mostly common surgical method for treating cataracts, and determining that the optimal phacoemulsification energy is dependent on measuring the hardness of the lens. This study explored the use of an ultrasound needle transducer for invasive measurements of ultrasound attenuation coefficient to evaluate the hardness of the cataract lens. A 47 MHz high-frequency needle transducer with a diameter of 0.9 mm was fabricated by a polarized PMN-33%PT single crystal in the present study. The attenuation coefficients at different stages of an artificial porcine cataract lens were measured using the spectral shift approach. The hardness of the cataract lens was also evaluated by mechanical measurement of its elastic properties. The results demonstrated that the ultrasonic attenuation coefficient was increased from 0.048 ± 0.02 to 0.520 ± 0.06 dB mm -1 MHz -1 corresponding to an increase in Young's modulus from 6 ± 0.4 to 96 ± 6.2 kPa as the cataract further developed. In order to evaluate the feasibility of combining needle transducer and phacoemulsification probe for real-time measurement during cataract surgery, the needle transducer was mounted on the phacoemulsification probe for a vibration test. The results indicated that there was no apparent damage to the tip of the needle transducer and the pulse-echo test showed that a good performance in sensitivity was maintained after the vibration test.

  8. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  9. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  10. The tipping point: A mathematical model for the profit-driven abandonment of restaurant tipping

    Science.gov (United States)

    Clifton, Sara M.; Herbers, Eileen; Chen, Jack; Abrams, Daniel M.

    2018-02-01

    The custom of voluntarily tipping for services rendered has gone in and out of fashion in America since its introduction in the 19th century. Restaurant owners that ban tipping in their establishments often claim that social justice drives their decisions, but we show that rational profit-maximization may also justify the decisions. Here, we propose a conceptual model of restaurant competition for staff and customers, and we show that there exists a critical conventional tip rate at which restaurant owners should eliminate tipping to maximize profits. Because the conventional tip rate has been increasing steadily for the last several decades, our model suggests that restaurant owners may abandon tipping en masse when that critical tip rate is reached.

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... one or two x-ray tubes and a television-like monitor that is located in the examining ... display screen that looks like a computer or television monitor. The image is created based on the ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... monitor that is located in the examining room. Fluoroscopy, which converts x-rays into video images, is ... the liver). A stent is then placed under fluoroscopy extending from the portal vein into the hepatic ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ... not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic ...

  14. A Rotor Tip Vortex Tracing Algorithm for Image Post-Processing

    Science.gov (United States)

    Overmeyer, Austin D.

    2015-01-01

    A neurite tracing algorithm, originally developed for medical image processing, was used to trace the location of the rotor tip vortex in density gradient flow visualization images. The tracing algorithm was applied to several representative test images to form case studies. The accuracy of the tracing algorithm was compared to two current methods including a manual point and click method and a cross-correlation template method. It is shown that the neurite tracing algorithm can reduce the post-processing time to trace the vortex by a factor of 10 to 15 without compromising the accuracy of the tip vortex location compared to other methods presented in literature.

  15. The effect of substrate on electric field enhancement of Tip-enhanced Raman spectroscopy (TERS)

    Science.gov (United States)

    Bahreini, Maryam

    2018-01-01

    The characterization of materials down to a few-molecule level is a key challenge in nanotechnology. Raman spectroscopy is a powerful method that provides chemical information via nondestructive vibrational fingerprinting. Unfortunately, this method suffers from signal weakness which prevents the study of small quantities. Tip-enhanced Raman spectroscopy (TERS) which combines the chemical sensitivity of Raman spectroscopy (RS) with high spatial resolution of scanning probe microscopy (SPM), provides chemical images of surfaces at the nanometer scale. In this method, irradiation of an SPM tip by a focused laser beam results in enhancement of local electric field via two reasons of localized surface plasmon resonance and lightning rod effect. This enhancement leads to the enhancement in Raman intensity from the sample surface in the vicinity of tip. In all TERS measurements, samples should be located on a substrate. In this paper, the dependence of the electric field enhancement to the substrate has been investigated. In simulations, three-dimensional finite-difference time-domain (3D-FDTD) method is used for numerical solution of Maxwell's equations. Our results show that the electric field enhancement is weak for the tip alone case. Introducing a substrate provides further electric field enhancement via near field electromagnetic dipole-dipole coupling between the tip and substrate. Since the side-illumination geometry is used for laser irradiation, the vertical component of the incident field plays a dominant role in the electric field enhancement. Therefore, the coupling effect between the tip and the substrate is the key contribution to the enhancement. For the case of silicon tip and the gold substrate, the electric field enhancement is improved considerably. There is an optimal tip size for TERS because of the competing effects of the radiation damping and the surface scattering of the tip. The results show the substrate as an effective tool for the

  16. Application of fluorescence analysis for evaluation of heat stability of Scotch pine needles after ground fires

    Directory of Open Access Journals (Sweden)

    I. V. Kosov

    2017-10-01

    Full Text Available This paper discusses the possibility of using fluorescent methods to assess the thermal effects on Scots pine needles’ assimilation apparatus. Two types of experimental studies were carried out. The assessment of the primary heat resistance of the needles from the forest stand previously unaffected by fire lies at the heart of the first one. To assess the effect of temperature stress on the pine needles’ photosynthetic apparatus functioning, the experiments on modeling a convective flow, simulating the ground fire effect were carried out. The second year needles from the 1st class trees of the green moss-and-motley group of forest types located in the forest-steppe zone of Southern Siberia were studied. According to Fv / Fm fast fluorescence parameter (the maximum photochemical quantum yield of photosystem II, it was demonstrated that after the heat stress, the assimilation apparatus of pine needles can be restored at different rates. This rate depends on the duration and intensity of heating. The second experiment was based upon the task of determining the ability to restore the assimilation apparatus of pine needles after the repeated influence of sub-lethal temperatures on plants in the recovery period after a ground fire of the previous year. Based on the analysis of the parameters of fast and delayed fluorescence, it was possible to detect differences in thermal resistance and the rates of pine needles’ photosynthetic activity reestablishment, which indicates modification of physiological processes in plants under the influence of the thermal stress factor, forming a positive acclimation effect. Thus, fluorescent methods can be used to diagnose the thermal resistance of needles. In particular, the indicator of delayed fluorescence as a criterion for assessing the resistance of the assimilation apparatus in response to the repeated action of stress factors during the recovery from fire. Fv / Fm ratio can be used to assess the response

  17. Direction of the J-Tip of the Guidewire to Decrease the Malposition Rate of an Internal Jugular Vein Catheter

    Directory of Open Access Journals (Sweden)

    Byeong jun Ahn

    2015-11-01

    Full Text Available Background We hypothesized that the direction of the J-tip of the guidewire during insertion into the internal jugular vein (IJV might determine its ultimate location. Methods In this study, 300 patients between the ages of 18 and 99 years who required central venous catheterization via IJV in the emergency department enrolled for randomization. IVJ catheterization was successful in 285 of 300 patients. An independent operator randomly prefixed the direction of the J-tip of the guidewire to one of three directions. Based on the direction of the J-tip, patients were allocated into three groups: the J-tip medial-directed group (Group A, the lateral-directed group (Group B, or the downward-directed group (Group C. Postoperative chest radiography was performed on all patients in order to visualize the location of the catheter tip. A catheter is considered malpositioned if it is not located in the superior vena cava or right atrium. Results Of the total malpositioned catheter tips (8 of 285; 2.8%, the majority (5 of 8; 62.5% entered the contralateral subclavian vein, 2 (25.0% were complicated by looping, and 1 (12.5% entered the ipsilateral subclavian vein. According to the direction of the J-tip of the guidewire, the incidence of malpositioning of the catheter tip was 4 of 92 in Group A (4.3%, 4 of 96 in Group B (4.2%, and there were no malpositions in Group C. There were no significant differences among the three groups (p = 0.114. Conclusions The direction of the J-tip of the guidewire had no statistically significant effect on incidence of malpositioned tips.

  18. Evaluating the advances and use of hypodermic needles in dentistry.

    Science.gov (United States)

    Boynes, Sean G

    2014-10-01

    Different injection techniques and patient management methodologies have been proposed to decrease the fear patients may have concerning dental needles. Dental providers should have an understanding of the technological advances, changes in techniques, and patient perceptions associated with the hypodermic needle. This article provides an overview of the pain perception process associated with dental injections. It reviews the two main sensory nerve fibers associated with injection pain and discusses needle properties as well as complications and adverse occurrences.

  19. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  20. Active Piezoelectric Structures for Tip Clearance Management Assessed

    Science.gov (United States)

    1995-01-01

    Managing blade tip clearance in turbomachinery stages is critical to developing advanced subsonic propulsion systems. Active casing structures with embedded piezoelectric actuators appear to be a promising solution. They can control static and dynamic tip clearance, compensate for uneven deflections, and accomplish electromechanical coupling at the material level. In addition, they have a compact design. To assess the feasibility of this concept and assist the development of these novel structures, the NASA Lewis Research Center developed in-house computational capabilities for composite structures with piezoelectric actuators and sensors, and subsequently used them to simulate candidate active casing structures. The simulations indicated the potential of active casings to modify the blade tip clearance enough to improve stage efficiency. They also provided valuable design information, such as preliminary actuator configurations (number and location) and the corresponding voltage patterns required to compensate for uneven casing deformations. An active ovalization of a casing with four discrete piezoceramic actuators attached on the outer surface is shown. The center figure shows the predicted radial displacements along the hoop direction that are induced when electrostatic voltage is applied at the piezoceramic actuators. This work, which has demonstrated the capabilities of in-house computational models to analyze and design active casing structures, is expected to contribute toward the development of advanced subsonic engines.

  1. Experimental model of intervertebral disc degeneration by needle puncture in Wistar rats

    Energy Technology Data Exchange (ETDEWEB)

    Issy, A.C.; Castania, V.; Castania, M. [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Salmon, C.E.G. [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Nogueira-Barbosa, M.H. [Divisão de Radiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Bel, E. Del [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Defino, H.L.A. [Departamento de Biomecânica, Medicina e Reabilitação do Sistema Locomotor, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-03-15

    Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration.

  2. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  3. Crack Tip Mechanics in Distortion Gradient Plasticity

    DEFF Research Database (Denmark)

    Fuentes-Alonso, Sandra; Martínez Pañeda, Emilio

    2017-01-01

    The important role of geometrically necessary dislocations in structural integrity assessment has encouraged an extensive use of strain gradient plasticity theories to characterize the behavior at the small scales involved in crack tip deformation. However, despite the popularity of Distortion...... Gradient Plasticity (DGP), the influence on crack tip mechanics of DGP's distinguishing features that entail superior modelling capabilities has not been investigated yet. In this work crack tip fields are thoroughly examined by implementing the higher order theory of DGP in an implicit finite element...

  4. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    Science.gov (United States)

    Shin, K. W.; Andersen, P.

    2015-12-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached eddy simulations (DES) are made for cavitating flows on three tip- modified propellers, of which one is a reference propeller having an experimental result from a cavitation tunnel test with a hull model, and the other two are modified from the reference propeller by altering the blade tip loading. DES results have been validated against the experiment in terms of sheet and cloud cavitation. In DES, non-uniform hull wake is modelled by using the inlet flow and momentum sources instead of including a hull model. A 4-bladed Kappel propeller with a smooth tip bending towards the suction side is used as the reference propeller. For the reference propeller, sheet cavitation extends over a whole chord length in the hull wake peak. As the blade gets out of the wake peak, the rear part of sheet cavity is detached in a form of cloud cavitation. For the reference propeller, the tip pitch reduction from the maximum is about 35%. When decreasing the tip pitch reduction to 10%, tip vortex cavitation is formed and cloud cavitation is significantly weakened. When increasing the tip pitch reduction to 60%, sheet cavitation slightly moves to inner radii and cloud cavitation grows larger.

  5. Rapid analysis of raw solution samples by C18 pipette-tip electrospray ionization mass spectrometry.

    Science.gov (United States)

    Wang, Haixing; So, Pui-Kin; Ng, Tsz-Tsun; Yao, Zhong-Ping

    2014-09-24

    A C18 pipette-tip electrospray ionization mass spectrometry technique was developed for rapid analysis of raw solution samples. In this technique, a C18 pipette tip was employed for rapid purification and enrichment of analytes in raw sample solutions. The adsorbed analytes were eluted by solvents supplied by a syringe and a syringe pump, and a high voltage was applied onto the syringe needle to induce electrospray ionization at the pipette tip end for mass spectrometric analysis. This technique is simple, easy to assemble, enables generation of stable and reproducible signals, and can be conveniently used for qualitative and quantitative analysis of raw solution samples. Analysis by the technique only involved simple sample preparation procedures followed by direct mass spectrometric detection, all of which could be completed within minutes, while the analytical performances of the technique, including the limit of detection, limit of quantitation, liner range, accuracy and precision, were comparable to those by conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Foreign Body in the Liver: Sewing Needle

    Directory of Open Access Journals (Sweden)

    Yeliz Akturk

    2013-10-01

    Full Text Available Foreign body ingestion is a frequent clinical problem. Many foreign bodies go through the alimentary system without causing any damage. Incisory and penetrative foreign bodies may migrate and stay in the neighboring organs after perforation. Nevertheless this is an unusual case. The foreign bodies may be found outside of the gastrointestinal system and computed tomography is helpfull for localization and to identify their relationship between surrounding tissues. Here we report of a case in which a swallowed needle perforates duodenum and penetrates the liver.

  7. [Levels and distribution of PCBs and organochlorine pesticides in the air, pine needles, and human milk].

    Science.gov (United States)

    Kozul, Darija; Romanić, Snjezana Herceg

    2010-09-01

    This review presents the findings on the distribution and levels of 20 congeners of polychlorinated biphenyls (PCBs) and 7 organochlorine pesticides (OCPs) all over the world, based on measurements in samples of air, human milk and pine needles. The Institute for Medical Research and Occupational Health has been conducting research in all three matrices for many years, and this review summarises its results too. Significant decrease in concentrations of organochlorine compounds has been seen after the legal ban of their use, but that decresing trend has been slowed down and they are still found in all samples. In general, higher PCB levels are found in samples from urban locations, pesticides levels are higher in samples from locations where has been their probable usage in agriculture, while HCB levels are usually indicator of industrial activity.γ-HCH has been found in the highest concentration in air and pine needles samples, while in humans DDE and β-HCH are the most abundant compounds. Indicator PCB congeners are also differently present in environment and humans: in air and pine needles lower-chlorinated, more volatile PCB congeners have higher concentrations while in humans that goes for more persistent higher-chlorinated PCB congeners. Among toxic ortho-substituted PCB congeners in human and environmental samples the most abundant is PCB-118 while three non-ortho substituted congeners (PCB-77, PCB-126 and PCB-169) that are the most toxic ones are rarely detected. From organochlorine pesticides, DDD is found in lowest concentrations in all samples.

  8. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    Science.gov (United States)

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion

  9. Smooth School Transitions: Tips for Military Families

    Science.gov (United States)

    ... Life Listen Text Size Email Print Share Smooth School Transitions: Tips for Military Families Page Content Article ... Internet is a great resource for this. District & School Web sites Parents and children can visit the ...

  10. Helping Your Child: Tips for Parents

    Science.gov (United States)

    ... inactive computer and video games, or listening to music on hand-held devices while sitting down. Tips ... habits or weight. Remember, you play the biggest role in your children's lives. You can help your ...

  11. Tips for Teens with Diabetes: About Diabetes

    Science.gov (United States)

    National Diabetes Education Program (NDEP), 2010

    2010-01-01

    Diabetes is a serious disease. It means that one's blood glucose, also called blood sugar, is too high. Having too much glucose in a person's blood is not healthy. This paper offers tips for managing diabetes.

  12. Winter Safety Tips for Older Adults

    Science.gov (United States)

    Winter Safety Tips for Older Adults Expert Information from Healthcare Professionals Who Specialize in the Care of ... thick clothing. Think about getting your thermals! –Essential winter wears: hats, gloves or preferably mittens, winter coat, ...

  13. Essential Outdoor Sun Safety Tips for Winter

    Science.gov (United States)

    ... Vitamin D Essential Outdoor Sun Safety Tips for Winter Winter sports enthusiasts are at increased risk for overexposure ... associated with sun exposure. "It's easy to associate winter with frostbite and windburn, but most people are ...

  14. Can't sleep? Try these tips

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000853.htm Can't sleep? Try these tips To use the sharing features ... time. But if it happens often, lack of sleep can affect your health and make it hard ...

  15. Sleep Tips: 7 Steps to Better Sleep

    Science.gov (United States)

    ... turn every night. Consider simple tips for better sleep, from setting a sleep schedule to including physical activity in your daily ... factors that can interfere with a good night's sleep — from work stress and family responsibilities to unexpected ...

  16. Impetigo: Tips for Treatment and Prevention

    Science.gov (United States)

    ... DO Videos Contact Close ‹ Back to Healthy Living Impetigo: Tips for Treatment and Prevention The symptoms of ... to other parts of their bodies. Causes of Impetigo Impetigo usually affects preschool and school-aged children, ...

  17. Next Stop Adulthood: Tips for Parents

    Science.gov (United States)

    ... Email Print Share Next Stop Adulthood: Tips For Parents Page Content Article Body Becoming a young adult is exciting, difficult, and scary for both parents and teens. It is a time of increasing ...

  18. 6 Tips: IBS and Complementary Health Practices

    Science.gov (United States)

    ... health practice for IBS, here are 6 tips: Hypnotherapy (hypnosis). This practice involves the power of suggestion by ... IBS. According to reviews of the scientific literature, hypnotherapy may be a helpful treatment for managing IBS ...

  19. Tips to Manage Anxiety and Stress

    Science.gov (United States)

    ... 2018 Conference Snapshot Tips to Manage Anxiety and Stress When you're feeling anxious or stressed, the ... Subscribe to ADAA Triumph: Free Monthly E-News Stress Relief Kits Feeling stressed? Get an ADAA stress ...

  20. Tipping points in Anthropocene fluvial dynamics

    Science.gov (United States)

    Notebaert, Bastiaan; Broothaerts, Nils; Verstraeten, Gert; Berger, Jean-François; Houbrechts, Geoffrey

    2016-04-01

    Many rivers have undergone dramatic changes over the last millennia due to anthropogenic on- and offsite impacts. These changes have important implications for the geomorphic and hydrological functioning of the river. In this study we compare the influence of large-scaled off-site anthropogenic impact on three European river systems. We do this using traditional geomorphological methods, combined with palynological and archaeological data; for each catchment a Holocene sediment budget was constructed. The Dijle catchment is located in the central Belgian loess belt, and has undergone intense agriculture for at least the last 2000 year. Pre-Anthropocene floodplain are big marshes lacking a well-established river channel. Anthropogenic deforestation in the headwaters resulted in a sediment pulse from the Bronze Age on. In the main floodplain sediments gradually covered the peat layer, starting near a newly formed river channel and expanding over time towards the floodplain edges. In contrast, this transition is abrupt in the smaller tributary floodplains. Comparison with palynological data shows that this abrupt transition occurs when human impact reaches a certain threshold. The Valdaine region is located in the French Pre-Alps. Floodplain deposition increased over time since the Neolithic time period due to human induced and fire related soil erosion. This general aggradation trend is however interrupted by three major river incision phases which are caused by human land abandonment and dry periods. A second major change in floodplain geomorphology occurs during the High Roman Period and the last 800 year: the fine-grained meandering river changes to a gravel loaded braided river. During this period the upstream mountain reaches became a major sediment source due to deforestation, possibly combined with climate change. During the last century reforestation and land abandonment has led to a new incision phases, and floodplain are now a major source of gravel while

  1. Tip velocity tracking control for elastic manipulators

    Science.gov (United States)

    Sever, Manfred Dieter Martin

    A unique approach to tip velocity control of an elastic robotic manipulator is presented. This method has potential application in teleoperation control and in applications where the trajectory is generated in real-time. Control is effected by reducing the tip velocity tracking error between the desired tip velocity and the measured tip velocity. Thus, in teleoperation, the concept of dead reckoning is used, so that while the manipulator's desired tip velocity is specified, the goal is for the tip to follow a path, leading toward a desired terminal position. This is done by concentrating the controller's effort on the manipulator tip while allowing the manipulator's links to deform., The controller utilizes a gain scheduling scheme to arrive at an appropriate feedback law. The control algorithm is implemented using a parallel-processing scheme on a multiprocessor system which consists of INMOS TransputersRTM . Experimental results are obtained using Radius, the Space Robotics Laboratory Facility at the University of Toronto Institute for Aerospace Studies. Radius was designed to serve specifically as a test-bed for the development and evaluation of control methods for elastic manipulators. For the present work Radius is configured as a two-link manipulator with both links structurally flexible. One of the trajectories used for the simulations and experiment is a square, which is quite difficult for an elastic manipulator to execute. This box trajectory is more demanding than trajectories typically executed by Canadarm and so link elasticity becomes an important consideration. The effect of elasticity is demonstrated using an independent joint PD controller. In simulation, excellent tip velocity tracking was achieved using the proposed controller. In the experiment, reasonable accuracy in following the desired tip path was attained, however, disturbances, mainly a result of unmodeled joint dynamics, caused degraded performance. The controller may be improved by

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... consists of a radiographic table, one or two x-ray tubes and a television-like monitor that is located ... guide a catheter, a long, thin, hollow plastic tube into the vessel. Using real time x-ray guidance, your doctor will then guide the catheter ...

  3. Relationship between buckling of acupuncture needles and the handle type.

    Science.gov (United States)

    Zhang, Claire Shuiqing; Pannirselvan, Muthu; Xue, Charlie Changli; Xie, Yi Min

    2014-10-01

    Most popular single-use acupuncture needles consist of a stainless steel shaft with a handle made of copper coil or plastic stick. To determine the strengths and weaknesses of these two handle types for needle buckling. The buckling load for acupuncture needles with these two different handle types was determined using a digital scale, and the stiffness of stainless steel wires used in different types of acupuncture needles was measured using a Dynamic Mechanical Analysis machine. This study showed that an acupuncture needle with a copper coil handle was far more susceptible to buckling than a needle with a plastic stick handle. The average buckling force of acupuncture needles with plastic stick handles was 46.7% higher than that with copper coil handles for needles of 0.25 mm×30 mm, and 30.8% higher for needles of 0.25 mm×60 mm. Replacing a copper coil handle with a plastic stick handle could save about 100 tonnes of copper wires and 20 million metres of medical grade stainless steel wire a year worldwide. The results from this study suggest that the common practice of using coiled copper for handles on acupuncture needles should be re-evaluated. Replacing a copper coil handle with a plastic stick handle would significantly reduce needle buckling and improve patient comfort and safety. This would also reduce the consumption of copper and medical grade stainless steel wire considerably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Confirming PICC tip position during insertion with real-time information.

    Science.gov (United States)

    Barton, Andrew

    2016-01-27

    Peripherally inserted central catheters (PICCs) play a fundamental role in patient care in a variety of clinical and healthcare settings. Tip location is important for both safety and efficacy. New technologies may offer the possibility of safer, more efficient and more effective insertion. A prospective evaluation was carried out of a system providing real-time information on the tip's location, direction, and depth during insertion in a total of 488 patients at a single centre (65 patients in the initial study, plus follow-on case series reports in 423 patients). No tip malpositions were reported and, as a result, the institution has been able to waive the requirement for confirmatory chest X-ray after PICC insertion, thus minimising the delay before the PICC can be used and increasing staff and patient confidence in the procedure.

  5. Artifact-reduced imaging of biopsy needles with 2D multispectral imaging.

    Science.gov (United States)

    Weber, Hans; Hargreaves, Brian A; Daniel, Bruce L

    2017-12-29

    Magnetic resonance (MR) guidance for biopsy procedures requires high intrinsic soft-tissue contrast. However, artifacts induced by the metallic needle can reduce its localization and require low-susceptibility needle materials with poorer cutting performance. In a proof of concept, we demonstrate the feasibility of 2D multispectral imaging (2DMSI) for both needle tracking and for needle artifact reduction for more precise needle localization and to enable the usage of needle materials with higher susceptibility. We applied 2DMSI for imaging of MR-compatible biopsy needles, conventional stainless-steel needles, and mixed-material needles and compared it to conventional techniques. In addition, we exploited intrinsic off-resonance information for passive needle tracking. 2DMSI achieved a stronger reduction of the needle artifact compared to conventional techniques. For the mixed-material needles, the artifact was reduced to a level below that for MR-compatible needles with conventional imaging. The passive tracking also improved the ability to pinpoint the needle. 2DMSI is promising for both needle tracking and artifact-reduced imaging of biopsy needles for a more precise needle localization. 2DMSI may be particularly promising for needles inducing large distortions or for targeting of small lesions. In addition, it may enable the use of needle materials with higher susceptibility and potentially better sampling performance. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Effect of needle brand, needle bevel grind, and silicone lubrication on contamination of joints with tissue and hair debris after arthrocentesis.

    Science.gov (United States)

    Waxman, Sarah J; Adams, Stephen B; Moore, George E

    2015-04-01

    To assess contamination of joints with tissue and hair debris after arthrocentesis. Experimental. Fetlock joint tissues (n = 6 horses). Soft tissue flaps including joint capsule were dissected from the dorsal aspect of fetlock joints of 6 anesthetized horses leaving an intact proximal base ("live" model) or with complete excision and immediate mounting to a wooden frame ("fresh" model). Needles were inserted through joint tissues and saline solution was flushed through them into tissue culture plate wells, and then examined for tissue and hair debris. Nine needle types were assessed; variables included needle brand, needle bevel grind, needle size, and silicone lubrication. No significant difference was detected between "live" and "fresh" models for hair or tissue contamination. Compared to 20 g hypodermic needles, 19 g lubricated and 19 g non-lubricated needles had a significantly greater odds ratio (OR) for hair contamination. Nineteen-gauge non-lubricated needles had a significantly greater OR for hair contamination than 19 g lubricated needles. No significant differences in ORs were identified between type of needle bevel grind, brands of disposable hypodermic needles, or brands of spinal needles for hair or tissue contamination. Nineteen-gauge needles significantly increase the risk of joint contamination with hair compared to 20 g needles; non-lubricated 19 g needles have the greatest risk. All other needle types tested in this study have similar risks for tissue and hair contamination after arthrocentesis. © Copyright 2014 by The American College of Veterinary Surgeons.

  7. Tipping the balance: robustness of tip cell selection, migration and fusion in angiogenesis.

    Directory of Open Access Journals (Sweden)

    Katie Bentley

    2009-10-01

    Full Text Available Vascular abnormalities contribute to many diseases such as cancer and diabetic retinopathy. In angiogenesis new blood vessels, headed by a migrating tip cell, sprout from pre-existing vessels in response to signals, e.g., vascular endothelial growth factor (VEGF. Tip cells meet and fuse (anastomosis to form blood-flow supporting loops. Tip cell selection is achieved by Dll4-Notch mediated lateral inhibition resulting, under normal conditions, in an interleaved arrangement of tip and non-migrating stalk cells. Previously, we showed that the increased VEGF levels found in many diseases can cause the delayed negative feedback of lateral inhibition to produce abnormal oscillations of tip/stalk cell fates. Here we describe the development and implementation of a novel physics-based hierarchical agent model, tightly coupled to in vivo data, to explore the system dynamics as perpetual lateral inhibition combines with tip cell migration and fusion. We explore the tipping point between normal and abnormal sprouting as VEGF increases. A novel filopodia-adhesion driven migration mechanism is presented and validated against in vivo data. Due to the unique feature of ongoing lateral inhibition, 'stabilised' tip/stalk cell patterns show sensitivity to the formation of new cell-cell junctions during fusion: we predict cell fates can reverse. The fusing tip cells become inhibited and neighbouring stalk cells flip fate, recursively providing new tip cells. Junction size emerges as a key factor in establishing a stable tip/stalk pattern. Cell-cell junctions elongate as tip cells migrate, which is shown to provide positive feedback to lateral inhibition, causing it to be more susceptible to pathological oscillations. Importantly, down-regulation of the migratory pathway alone is shown to be sufficient to rescue the sprouting system from oscillation and restore stability. Thus we suggest the use of migration inhibitors as therapeutic agents for vascular

  8. Preschool Needle Pain Responding: Establishing 'Normal'.

    Science.gov (United States)

    Waxman, Jordana A; DiLorenzo, Miranda G; Pillai Riddell, Rebecca R; Flora, David B; Greenberg, Saul; Garfield, Hartley

    2017-06-01

    The current study sets forth to provide descriptive data for preschool vaccination pain responding as well as examine longitudinal relationships over early childhood. Growth mixture modeling was first used to describe stable subgroups of preschoolers on the basis of their pain response patterns over 2-minutes post-needle. Secondly, a parallel-process growth curve model was used to assess the stability of acute pain responding from 12 months of age to preschool age. Specifically, we examined whether preschool pain-related distress or regulation could be predicted from 12-month acute pain responding. Preschool participants were part of a Canadian longitudinal cohort (The Opportunities to Understand Childhood Hurt [OUCH] cohort; N = 302). Growth mixture modeling analyses discerned 3 distinct groups of preschoolers, with an important minority not regulating to low-no pain by 2 minutes post-needle. There were no significant associations between 12-month and preschool pain responding. These results highlight the steep trajectory of development between these different stages of early childhood and the variability of pain responding at the preschool vaccination. This study provides descriptive data for preschool vaccination pain responding as well as examines longitudinal relationships over early childhood. Demonstrating significantly different pain patterns from infancy, 25% of preschoolers are displaying suboptimal regulation trajectories. This considerable minority poses a significant concern because of the established trajectory of phobia onset in middle childhood. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.

  9. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  10. A tip-attached tuning fork sensor for the control of DNA translocation through a nanopore.

    Science.gov (United States)

    Hyun, Changbae; Kaur, Harpreet; Huang, Tao; Li, Jiali

    2017-02-01

    In this work, we demonstrate that a tuning fork can be used as a force detecting sensor for manipulating DNA molecules and for controlling the DNA translocation rate through a nanopore. One prong of a tuning fork is glued with a probe tip which DNA molecules can be attached to. To control the motion and position of the tip, the tuning fork is fixed to a nanopositioning system which has sub-nanometer position control. A fluidic chamber is designed to fulfill many requirements for the experiment: for the access of a DNA-attached tip approaching to a nanopore, for housing a nanopore chip, and for measuring ionic current through a solid-state nanopore with a pair of electrodes. The location of a nanopore is first observed by transmission electron microscopy, and then is determined inside the liquid chambers with an optical microscope combined with local scanning the probe tip on the nanopore surface. When a DNA-immobilized tip approaches a membrane surface near a nanopore, free ends of the immobilized DNA strings can be pulled and trapped into the pore by an applied voltage across the nanopore chip, resulting in an ionic current reduction through the nanopore. The trapped DNA molecules can be lifted up from the nanopore at a user controlled speed. This integrated apparatus allows manipulation of biomolecules (DNA, RNA, and proteins) attached to a probe tip with sub-nanometer precision, and simultaneously allows measurement of the biomolecules by a nanopore device.

  11. Estimation of plasma ion saturation current and reduced tip arcing using Langmuir probe harmonics.

    Science.gov (United States)

    Boedo, J A; Rudakov, D L

    2017-03-01

    We present a method to calculate the ion saturation current, I sat , for Langmuir probes at high frequency (>100 kHz) using the harmonics technique and we compare that to a direct measurement of I sat . It is noted that the I sat estimation can be made directly by the ratio of harmonic amplitudes, without explicitly calculating T e . We also demonstrate that since the probe tips using the harmonic method are oscillating near the floating potential, drawing little power, this method reduces tip heating and arcing and allows plasma density measurements at a plasma power flux that would cause continuously biased tips to arc. A multi-probe array is used, with two spatially separated tips employing the harmonics technique and measuring the amplitude of at least two harmonics per tip. A third tip, located between the other two, measures the ion saturation current directly. We compare the measured and calculated ion saturation currents for a variety of plasma conditions and demonstrate the validity of the technique and its use in reducing arcs.

  12. Does Combined Use of the J-tip® and Buzzy® Device Decrease the Pain of Venipuncture in a Pediatric Population?

    Science.gov (United States)

    Kearl, Y Liza; Yanger, Sheryl; Montero, Sandra; Morelos-Howard, Elizabeth; Claudius, Ilene

    2015-01-01

    Both the J-tip® (a needle-free device for subcutaneous delivery of lidocaine) and the Buzzy® (a cooled, vibrating device to employ gate control to minimize procedural pain) have shown some efficacy in diminishing the pain of venipuncture. To develop an optimal protocol for pre-venipuncture/IV start pain management by investigating the impact of adding the use of Buzzy® prior to the use of the J-tip®. Pediatric emergency department patients aged 1 month to 21 years were prospectively enrolled in Phase 1 (J-tip® only) then Phase 2 (Buzzy®+J-tip®) for analgesia prior to venipuncture or IV start. Age-appropriate pain scale scores were collected for the subsequent procedure, as well the administration of lidocaine via J-tip®. With the combined intervention (phase 2), 14.2% of patients had a pain scale score >3 with venipuncture and 16.1% had a pain scale score >3 with application of the J-tip® itself. With no intervention for pain relief, 71% of patients experienced a pain scale score >3 for venipuncture. With the J-tip® alone (phase 1), 21% had a pain scale score >3 with venipuncture and 22.3% had a pain scale score >3 with application of the J-tip® itself. Patients receiving either intervention reported lower scores on pain scales during venipuncture or IV start than the no analgesia group. The combined intervention did not yield a significant decrease in scores on pain scale scores over the J-tip® alone. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Local variations in microfungal populations on Pinus sylvestris needles.

    Science.gov (United States)

    Gourbière, François; Debouzie, Domitien

    2003-10-01

    We studied the fungal colonization of Pinus sylvestris needles in two neighbouring sites, comparing stands of isolated and grouped trees. We observed large variations among the proportions of needles bearing fruit bodies of Cyclaneusma minus, Lophodermium pinastri, Verticicladium trifidum and black lines characteristic of L. pinastri colonization. Variations between sites and within trees were greater than that between stands or between trees. The frequency of L. pinastri colonization was negatively correlated with C. minus fruit body frequency, while the frequency of V. trifidum conidiophores was positively correlated with L. pinastri colonization frequency without fruiting, and negatively correlated with C. minus apothecia frequency. Although L. pinastri black lines and C. minus apothecia were nearly randomly associated on individual needles in each sample, the two fungi occupied different segments when they occupied the same needle. These patterns at needle and sample scales do not explain the negative correlation between the frequencies of these two species observed at larger scales. In each sample, frequency of V. trifidum conidiophores was highest on needles colonized by L. pinastri without fruiting. On individual needles, V. trifidum conidiophores developed on segments colonized by L. pinastri without fruiting, but not on segments bearing fruit bodies of L. pinastri or C. minus. These patterns at needle and sample scales were consistent with the correlations between frequencies observed at larger scales. These results were compared to variations observed with stand age and climate in others studies. The observed variations might result from both microclimate variations and fungal interactions.

  14. Effect of dietary mugwort ( Artemisia vulgaris L.) and pine needle ...

    African Journals Online (AJOL)

    The effects of dietary mugwort and pine needle powder supplementation on growth performance, serum cholesterol, and meat quality of broilers were evaluated in a 35 days feed trial. 200 one day old broilers were randomly allocated to five dietary treatments (0, 1 and 2% mugwort or 1 and 2% pine needle powder) with ...

  15. Needle-shaped and platelet growth of borax crystals

    International Nuclear Information System (INIS)

    Takoo, R.K.; Patel, B.R.; Joshi, M.S.

    1983-01-01

    Needle-shaped and platelet growth of borax crystals from solutions is reported. Results of microtopographical studies on both the varieties are discussed. It is suggested that a slow rate of evaporation favours needle growth and a faster rate is conducive to the growth of platelets. (author)

  16. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  17. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  18. Prevalence of needle-stick injuries, blood and body fluids ...

    African Journals Online (AJOL)

    Background: Health care workers are frequently exposed to needle-stick injuries, blood and body fluids in the performance of their duties. Aims and objectives: This study sought to determine the prevalence and pattern of occupational exposure to needle-stick injuries, blood and body fluid contamination among clinical and ...

  19. Prevalence of Needle Stick Injuries among Healthcare Workers in ...

    African Journals Online (AJOL)

    Background: Needle stick injuries represent one of the most important occupational hazards to which health workers are exposed. These injuries result from accidental piercing of the skin and or mucous membranes by sharp objects. Needle stick injuries carry the risk of exposure to blood-borne pathogens, especially ...

  20. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  1. PVA matches human liver in needle-tissue interaction

    NARCIS (Netherlands)

    de Jong, T.L.; Pluymen, L.H.; van Gerwen, D.J.; Kleinrensink, GJ; Dankelman, J.; van den Dobbelsteen, J.J.

    2017-01-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were

  2. ORIGINAL ARTICLES Door-to-needle time for administration of ...

    African Journals Online (AJOL)

    infarction (STEMI) were identified; 161 patients were eligible for the study. The median door-to-needle time achieved was 54 minutes (range 13 - 553 mins). A door-to-needle time of 30 minutes or less was achieved in 33 (20.5%) patients; 51.3% of the patients arrived by ambulance; 34% of patients had a pre-hospital 12- ...

  3. Darning Needle Impacted in the Male Urethra | Singla | African ...

    African Journals Online (AJOL)

    Foreign bodies of varied nature have been introduced into the urethra to achieve sexual stimulation. We report the case of a long (9.5 cm) darning needle impacted in the urethra of a male patient following urethral masturbation. After a failed trial at endoscopic extraction the needle had to be removed via open surgery.

  4. Importance of Fine Needle Aspiration in Evaluation of Single ...

    African Journals Online (AJOL)

    Background: Improvements in the sensitivity and specificity of biochemical thyroid tests, as well as the development of fine needle aspiration biopsy (FNA) and improved cytological techniques, have dramatically impacted clinical strategies for detecting and treating thyroid disorders. Fine needle aspiration is a safe and ...

  5. Characteristics of premixed flames stabilized in an axisymmetric curved-wall jet burner with tip modification

    KAUST Repository

    Kim, Daejoong

    2009-11-10

    The stabilization characteristics of premixed flames in an axisymmetric curved-wall jet burner have been experimentally investigated. This burner utilized the Coanda effect on top of a burner tip. The initially spherical burner tip was modified to a flat tip and a concave tip in order to improve flame stabilization by providing enough space for flow recirculation above the burner tip region. The flow characteristics have been visualized using a schlieren technique. Small-scale turbulence structure has been observed mainly in the interaction jet region (located downstream of the recirculation region) for large jet velocity (Reynolds number >11,500). An appreciable amount of air entrainment was exhibited from the half-angle of the jet spread, approximately 20. The averaged planar laser-induced fluorescence images of the flames for this large velocity demonstrated that the strong signal of OH radicals, representing reaction zones, existed in the recirculation zone, while it was weak in the interaction jet region due to intermittency and local extinction by the generation of small scale turbulence. The OH radical signals strengthened again in the merged jet region (downstream of the interaction jet region). In extreme cases of Reynolds number over 19,000, a unique flame exhibiting OH radicals only in the recirculation zone was observed for the concave tip. The flame stabilization has been mapped by varying jet velocity and equivalence ratio, and the result showed that the stabilization characteristics were improved appreciably from the initial spherical tip design, especially for rich mixtures. The flow fields measured by a laser Doppler velocimetry confirmed the existence of recirculation zone and the expansion of the recirculation zones for the modified tips. The temperature profile measured by a coherent anti-Stokes Raman spectroscopy exhibited an intermittent nature, especially near the recirculation zone.

  6. A training system for ultrasound-guided needle insertion procedures.

    Science.gov (United States)

    Zhu, Yanong; Magee, Derek; Ratnalingam, Rish; Kessel, David

    2007-01-01

    Needle placement into a patient body under guidance of ultrasound is a frequently performed procedure in clinical practice. Safe and successful performance of such procedure requires a high level of spatial reasoning and hand-eye co-ordination skills, which must be developed through intensive practice. In this paper we present a training system designed to improve the skills of interventional radiology trainees in ultrasound-guided needle placement procedures. Key issues involved in the system include surface and volumetric registration, solid texture modelling, spatial calibration, and real-time synthesis and rendering of ultrasound images. Moreover, soft tissue deformation caused by the needle movement and needle cutting is realised using a mass-spring-model approach. These have led to a realistic ultrasound simulation system, which has been shown to be a useful tool for the training of needle insertion procedures. Preliminary results of a construct evaluation study indicate the effectiveness and usefulness of the developed training system.

  7. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  8. Quick Tips for Buying Medicines Over the Internet: A Consumer Safety Guide

    Science.gov (United States)

    ... Internet Quick Tips for Buying Medicines Over the Internet Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Make sure the site requires a prescription and has a pharmacist available for questions. Buy only from licensed pharmacies located in the United ...

  9. Pericardial cyst with atypical location: densimetric evaluation of mediastinal masses by computerized tomography

    International Nuclear Information System (INIS)

    Franquet, T.; Jiminez, F.J.; Eguizabal, C.; Bescos, J.M.

    1991-01-01

    We present a case of pericardial cyst with atypical location. CT has been very usefull for densitometric evaluation of mediastinal masses. Using a combination of cross-section diagnostic methods and fine-needle aspiration (FNA), we can carry out accurate diagnoses of cystic lesions located in uncommom sites. (Author)

  10. The N-terminus of IpaB provides a potential anchor to the Shigella type III secretion system tip complex protein IpaD

    Science.gov (United States)

    Dickenson, Nicholas E.; Arizmendi, Olivia; Patil, Mrinalini K.; Toth, Ronald T.; Middaugh, C. Russell; Picking, William D.; Picking, Wendy L.

    2014-01-01

    The type III secretion system (T3SS) is an essential virulence factor for Shigella flexneri, providing a conduit through which host-altering effectors are injected directly into a host cell to promote uptake. The type III secretion apparatus (T3SA) is comprised of a basal body, external needle, and regulatory tip complex. The nascent needle is a polymer of MxiH capped by a pentamer of invasion plasmid antigen D (IpaD). Exposure to bile salts (e.g. deoxycholate) causes a conformational change in IpaD and promotes recruitment of IpaB to the needle tip. It has been proposed that IpaB senses contact with host cell membranes, recruiting IpaC and inducing full secretion of T3SS effectors. While the steps of T3SA maturation and their external triggers have been identified, details of specific protein interactions and mechanisms have remained difficult to study due to the hydrophobic nature of the IpaB and IpaC translocator proteins. Here we explored the ability for a series of soluble N-terminal IpaB peptides to interact with IpaD. We found that DOC is required for the interaction and that a region of IpaB between residues 11–27 is required for maximum binding, which was confirmed in vivo. Furthermore, intramolecular FRET measurements indicated that movement of the IpaD distal domain away from the protein core accompanied the binding of IpaB11-226. Together these new findings provide important new insight into the interactions and potential mechanisms that define the maturation of the Shigella T3SA needle tip complex and provide a foundation for further studies probing T3SS activation. PMID:24236510

  11. N-terminus of IpaB provides a potential anchor to the Shigella type III secretion system tip complex protein IpaD.

    Science.gov (United States)

    Dickenson, Nicholas E; Arizmendi, Olivia; Patil, Mrinalini K; Toth, Ronald T; Middaugh, C Russell; Picking, William D; Picking, Wendy L

    2013-12-10

    The type III secretion system (T3SS) is an essential virulence factor for Shigella flexneri , providing a conduit through which host-altering effectors are injected directly into a host cell to promote uptake. The type III secretion apparatus (T3SA) is composed of a basal body, external needle, and regulatory tip complex. The nascent needle is a polymer of MxiH capped by a pentamer of invasion plasmid antigen D (IpaD). Exposure to bile salts (e.g., deoxycholate) causes a conformational change in IpaD and promotes recruitment of IpaB to the needle tip. It has been proposed that IpaB senses contact with host cell membranes, recruiting IpaC and inducing full secretion of T3SS effectors. Although the steps of T3SA maturation and their external triggers have been identified, details of specific protein interactions and mechanisms have remained difficult to study because of the hydrophobic nature of the IpaB and IpaC translocator proteins. Here, we explored the ability for a series of soluble N-terminal IpaB peptides to interact with IpaD. We found that DOC is required for the interaction and that a region of IpaB between residues 11-27 is required for maximum binding, which was confirmed in vivo. Furthermore, intramolecular FRET measurements indicated that movement of the IpaD distal domain away from the protein core accompanied the binding of IpaB11-226. Together, these new findings provide important new insight into the interactions and potential mechanisms that define the maturation of the Shigella T3SA needle tip complex and provide a foundation for further studies probing T3SS activation.

  12. Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis.

    Science.gov (United States)

    Facciorusso, Antonio; Stasi, Elisa; Di Maso, Marianna; Serviddio, Gaetano; Ali Hussein, Mohammed Salah; Muscatiello, Nicola

    2017-10-01

    Robust data in favour of a clear superiority of 22 versus 25 Gauge needles for endoscopic ultrasound-guided fine needle aspiration are still lacking. We aimed to compare the diagnostic sensitivity, specificity and safety of these two needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions. A computerized bibliographic search was restricted to randomized controlled trials only. Pooled effects were calculated using a random-effects model and expressed in terms of risk ratio and 95% confidence interval. We analysed seven trials with 689 patients and 732 lesions (295 sampled with 22 Gauge needle, 309 with 25 Gauge needle, and 128 with both needles). A non-significant superiority of 25 Gauge in terms of pooled sensitivity (risk ratio: 0.93, 0.91-0.95 versus 0.89, 0.85-0.94 of 22 Gauge needle; p  = 0.13) and no difference in terms of specificity (1.00, 0.98-1.00 in both groups; p  = 0.85) were observed. Sample adequacy was similar between the two devices (risk ratio: 1.03, 0.99-1.06; p  = 0.15). Very few adverse events were observed and did not impact on patient outcomes. Our meta-analysis reveals non-superiority of 25 Gauge over 22 Gauge; hence no definitive recommendations over the use of one particular device can be made.

  13. Single-Camera Closed-Form Real-Time Needle Tracking for Ultrasound-Guided Needle Insertion.

    Science.gov (United States)

    Najafi, Mohammad; Abolmaesumi, Purang; Rohling, Robert

    2015-10-01

    Many common needle intervention procedures are performed with ultrasound guidance because it is a flexible, cost-effective and widely available intra-operative imaging modality. In a needle insertion procedure with ultrasound guidance, real-time calculation and visualization of the needle trajectory can help to guide the choice of puncture site and needle angle to reach the target depicted in the ultrasound image. We found that it is feasible to calculate the needle trajectory with a single camera mounted directly on the ultrasound transducer by using the needle markings. Higher accuracy is achieved compared with other similar transducer-mounted needle trackers. We used an inexpensive, real-time and easy-to-use tracking method based on an automatic feature extraction algorithm and a closed-form method for pose estimation of the needle. The overall accuracy was 0.94 ± 0.46 mm. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Calibration of magnetic force microscopy tips by using nanoscale current-carrying parallel wires

    International Nuclear Information System (INIS)

    Kebe, Th.; Carl, A.

    2004-01-01

    Experimental results on the characterization of commercially available magnetic force microscopy (MFM) thin film tips as a function of an external magnetic field are presented. Magnetic stray fields with a definitive z-component (perpendicular to the substrate) and a magnetic field strength of up to H z =±45 Oe are produced with current carrying parallel nanowires with a thickness of t=60 nm, which are fabricated by electron-beam lithography. The magnetic fields are generated by electrical dc-currents of up to ±6 mA which are directed antiparallel through the nanowires. The geometry and the dimensions of the nanowires are systematically varied by choosing different wire widths w as well as separations b between the parallel wires for two different sets of samples. On the one hand, the wire width w is varied within 380 nm< w<2460 nm while the separation b≅450 nm between the wires is kept constant. On the other hand the separation b between the parallel wires is varied within 120 nm< b<5100 nm, while the wire width w=960 nm is kept constant. For all the geometrical configurations of parallel wires the resulting magnetic contrast is imaged by MFM at various tip lift-heights. By treating the MFM tip as a point probe, the analysis of the image contrast as a function of both the magnetic field strength and the tip lift height allows one to quantitatively determine the effective magnetic dipole and monopole moments of the tip as well as their imaginary locations within the real physical tip. Our systematic study quantitatively relates the above point-probe parameters to (i) the dimensions of the parallel wires and (ii) to the characteristic decay length of the z-component of the magnetic field of parallel wires. From this the effective tip-volume of the real thin film tip is determined which is relevant in MFM-imaging. Our results confirm the reliability of earlier tip calibration schemes for which nanofabricated current carrying rings were used instead of parallel

  15. Pressure Transducer Locations

    Data.gov (United States)

    National Aeronautics and Space Administration — Files are located here, defining the locations of the pressure transducers on the HIRENASD model. These locations also correspond to the locations that analysts...

  16. 78 FR 13402 - Proposed Collection; Comment Request for Tip Reporting Alternative Tip Agreement Used in the...

    Science.gov (United States)

    2013-02-27

    ... Used in the Cosmetology and Barber Industry AGENCY: Internal Revenue Service (IRS), Treasury. ACTION..., the IRS is soliciting comments concerning tip reporting alternative commitment used in the cosmetology...: Tip Reporting Alternative Commitment Agreement used in the Cosmetology and Barber Industry. OMB Number...

  17. 75 FR 11226 - Proposed Collection; Comment Request for Tip Reporting Alternative Tip Agreement Used in the...

    Science.gov (United States)

    2010-03-10

    ... Used in the Cosmetology and Barber Industry AGENCY: Internal Revenue Service (IRS), Treasury. ACTION..., the IRS is soliciting comments concerning Tip Reporting Alternative Commitment used in the Cosmetology...: Tip Reporting Alternative Commitment Agreement used in the Cosmetology and Barber Industry. OMB Number...

  18. Hip Pain: Dry Needling Versus Cortisone Injections.

    Science.gov (United States)

    2017-04-01

    Greater trochanteric pain syndrome (GTPS) is chronic, intermittent pain and tenderness on the outside of the hip. The medical community once thought that a swollen hip bursa was the source of such pain, which led to the use of corticosteroid injections to the bursa to help decrease swelling and pain. However, researchers now believe that injuries to the muscles and tendons around the hip are the actual cause of this pain, and that inflammation is often not involved. A study published in the April 2017 issue of JOSPT explores dry needling as an alternative to cortisone injections to reduce pain and improve function in patients with GTPS. J Orthop Sports Phys Ther 2017;47(4):240. doi:10.2519/jospt.2017.0504.

  19. Role of needle surface waxes in dynamic exchange of mono- and sesquiterpenes

    Directory of Open Access Journals (Sweden)

    J. Joensuu

    2016-06-01

    Full Text Available Biogenic volatile organic compounds (BVOCs produced by plants have a major role in atmospheric chemistry. The different physicochemical properties of BVOCs affect their transport within and out of the plant as well as their reactions along the way. Some of these compounds may accumulate in or on the waxy surface layer of conifer needles and participate in chemical reactions on or near the foliage surface. The aim of this work was to determine whether terpenes, a key category of BVOCs produced by trees, can be found on the epicuticles of Scots pine (Pinus sylvestris L. and, if so, how they compare with the terpenes found in shoot emissions of the same tree. We measured shoot-level emissions of pine seedlings at a remote outdoor location in central Finland and subsequently analysed the needle surface waxes for the same compounds. Both emissions and wax extracts were clearly dominated by monoterpenes, but the proportion of sesquiterpenes was higher in the wax extracts. There were also differences in the terpene spectra of the emissions and the wax extracts. The results, therefore, support the existence of BVOC associated to the epicuticular waxes. We briefly discuss the different pathways for terpenes to reach the needle surfaces and the implications for air chemistry.

  20. Combined 30-degree bevel up and down technique against 0-degree phaco tip for phacoemulsification surgery of hard cataracts

    Directory of Open Access Journals (Sweden)

    Joshi RS

    2017-06-01

    -degree tip can yield effective hard nucleus phacoemulsification, no statistically significant difference was found in EPT, CDE and NET between the two groups. Keywords: phacoemulsification, bevel up and bevel down phaco needle, effective phaco time, cumulative dissipated energy