WorldWideScience

Sample records for needle handling practices

  1. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  2. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice

    NARCIS (Netherlands)

    Scholten, H.J.; Pourtaherian, A.; Mihajlovic, N.; Korsten, H.; Bouwman, R.A.

    2017-01-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging

  3. [Design and application of silver needle-knife].

    Science.gov (United States)

    Sun, Guodong; Shi, Bin; Zhang, Benwu; Xu, Haidong

    2015-04-01

    A silver needle-knife which has the dual function of silver needle and needle-knife is designed. The main components of this silver needle-knife are approximately 50% silver and approximately 50% nichrome. The silver needle-knife is composed of five parts, including needle-knife tail, spiral handle; steering handle, needle-knife body and needle-knife edge. It converges the advantages of needle-knife and silver needle, which can cut loose of diseased tissue and peel adhesion of lesions, but also be heated with moxa cone and thermal therapeutic instrument, and connect with electroacupuncture apparatus. It has the function of warming channel and removing coldness, dispelling wind and eliminating dampness, resolving spasm and relieving pain, dredging the channel and so on. Due to the spiral handle and the steering handle, the operation is easier, which reduces the blindness of cutting and increase the safety. It is mainly used for soft tissue injury, rheumatism and rheumatoid arthritis, as well as degenerative diseases of spine and joint, and it has obvious efficacy on some internal medical diseases.

  4. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  5. Practices of Handling

    DEFF Research Database (Denmark)

    Ræbild, Ulla

    to touch, pick up, carry, or feel with the hands. Figuratively it is to manage, deal with, direct, train, or control. Additionally, as a noun, a handle is something by which we grasp or open up something. Lastly, handle also has a Nordic root, here meaning to trade, bargain or deal. Together all four...... meanings seem to merge in the fashion design process, thus opening up for an embodied engagement with matter that entails direction giving, organizational management and negotiation. By seeing processes of handling as a key fashion methodological practice, it is possible to divert the discourse away from...... introduces four ways whereby fashion designers apply their own bodies as tools for design; a) re-activating past garment-design experiences, b) testing present garment-design experiences c) probing for new garment-design experiences and d) design of future garment experiences by body proxy. The paper...

  6. Analysis of the NovoTwist pen needle in comparison with conventional screw-thread needles.

    Science.gov (United States)

    Aye, Tandy

    2011-11-01

    Administration of insulin via a pen device may be advantageous over a vial and syringe system. Hofman and colleagues introduce a new insulin pen needle, the NovoTwist, to simplify injections to a small group of children and adolescents. Their overall preferences and evaluation of the handling of the needle are reported in the study. This new needle has the potential to ease administration of insulin via a pen device that may increase both the use of a pen device and adherence to insulin therapy. © 2011 Diabetes Technology Society.

  7. Experiences with a new breast localisation needle

    International Nuclear Information System (INIS)

    Hergan, K.; Amann, T.; Doringer, W.; Hollenstein, P.

    1990-01-01

    In view of the increasing number of biopsies of non-palpable lesions of the female breast we found an ideal localisation system in the Hawkins breast localisation needle. Localisation was successful without technical problems in 31 out of 34 patients. The special advantages of the needle are its stability in position and excellent manoeverability due to the construction of the needle. The very simple handling of the needle is an advantage not only for the radiologist but also for the surgeon. (orig.) [de

  8. Effective Teaching Practices in Handling Non Readers

    Directory of Open Access Journals (Sweden)

    Jacklyn S. Dacalos

    2016-08-01

    Full Text Available The study determined the effective teaching practices in handling nonreaders. This seeks to answer the following objectives: describe the adjustments, effective strategies, and scaffolds utilized by teachers in handling nonreaders; differentiate the teachers’ reading adjustments, strategies and scaffolds in teaching nonreaders; analyze the teaching reading efficiency of nonreaders using effective teaching reading strategies; and find significant correlation of nonreaders’ grades and reading teachers’ reading adjustments, strategies and scaffolds. This study utilized mixed methods of research. Case studies of five public schools teachers were selected as primary subjects, who were interviewed in handling nonreaders in the areas of adjustments, strategies, and reading scaffolds. Actual teaching observation was conducted according to the five subjects’ most convenient time. In ascertaining the nonreaders’ academic performance, the students’ grades in English subject was analyzed using T-Test within subject design. Handling nonreaders in order to read and understand better in the lesson is an arduous act, yet; once done with effectiveness and passion, it yielded a great amount of learning success. Effective teaching practices in handling nonreaders comprised the use of teachers’ adjustments, strategies, and scaffolds to establish reading mastery, exposing them to letter sounds, short stories, and the use of follow-up. WH questions enhanced their reading performance significantly. Variations of reading teachers’ nature as: an enabler, a facilitator, a humanist, a behaviorist, and an expert, as regards to their teaching practices, were proven significant to students’ reading effectiveness.

  9. Needle stick injury in a radiology department: a decade analysis

    International Nuclear Information System (INIS)

    Sayani, R.; Rajani, A.

    2012-01-01

    Objectives: To determine the frequency of needle stick injury in health care workers of radiology department. Study type, settings and duration: Cross sectional, observational study conducted at the Radiology department of Aga Khan University hospital from January 2000 to May 2010. Subject and Methods: All self-reported needle stick injuries data of Health care workers of radiology department was recorded. The personnel involved (Radiologist, resident, radiographer, nurses etc), area of working and the causes of injury were identified including the procedural or post procedural details. Patient's status of hepatitis or blood borne infection was also noted. Data was recorded and analyzed in Excel worksheet. Results: A total of 55 health workers reported needle stick injuries at all sections of radiology departments with maximum number needle stick injuries at general radiography, fluoroscopy and IVP section. Radiographers and radiology residents received the maximum number of injuries. Major cause of injury was cannulation however, many injuries occurred during disposing or handling of bin. In majority of cases the patients were not infected with any known blood borne infections. Conclusions: Doctors and nurses get needle-stick injuries while carrying out clinical procedures, while, ancillary staff get infected post procedure during disposal of garbage. Policy message: Good occupational health and safety practices must be promoted to all staff. Safer disposal of needles is an important area where practice and procedure needs to be carefully reviewed. It is necessary to undertake a risk assessment, to offer counseling and Post Exposure Prophylaxis and treatment where necessary. (author)

  10. Knowledge, attitude and practices about needle stick injuries in health care workers

    International Nuclear Information System (INIS)

    Waqar, S.H.; Siraj, M.U.; Razzaq, Z.; Malik, Z.I.; Zahid, M.A.

    2011-01-01

    Objectives: To assess knowledge, attitude and practices about needle stick Injuries in health care workers. Study type, settings and duration: Hospital based study carried out at Pakistan Institute of Medical Sciences, Islamabad, from August 2010 to November 2010. Subjects and Methods: A self administered 19 items questionnaire was prepared which contained information about needle stick injuries, its awareness, frequency of injury and the protocols that were followed after an injury had occurred. These questionnaires were given to 500 health care workers working in different wards and theaters of the hospital after obtaining their informed written consent. The health care workers included doctors, nurses and paramedical staff of Pakistan Institute of Medical Sciences, Islamabad. The data was entered and analyzed using SPSS version 15. Results: A total of 500 health care workers filled the questionnaire and returned it. Out of these 416(83.2%) reported ever experiencing needle stick injuries in their professional life. Health care workers working in Emergency department were most frequently affected (65%) followed by those working in different wards (27%) and operation theatre (8%). Most (93.6%) workers had knowledge about needle stick injuries and only 6.4% were not aware of it. Needle stick injury occurred from a brand new (unused) syringe in 51.2% cases, while in 32.8% cases, the needle caused an injury after it had been used for an injection. In 5% cases, injury occurred with blood stained needles. The commonest reasons for needle injury in stick injuries were heavy work load (36.8%) followed by hasty work (33.6%) and needle recapping (18.6%). About 66% health care workers were already vaccinated against hepatitis B. Only 13% workers followed universal guidelines of needle stick injuries and no case was reported to hospital authorities. Conclusions: Health care workers had inadequate knowledge about the risk associated with needle stick injuries and do not

  11. Needle stick injuries during fine needle aspiration procedure: Frequency, causes and knowledge, attitude and practices of cytopathologists

    Directory of Open Access Journals (Sweden)

    Neeta Kumar

    2011-01-01

    Full Text Available Background: There is no study available on the frequency, predisposing factors and outcome of needle stick injury (NSI in cytopathologists who perform fine needle aspiration (FNA. Aim: To know the frequency, circumstances and sequlae of NSI sustained by cytopathologists, assess their knowledge about risks of NSI and attitudes and practices towards use of standard precautions and post-injury wound care. Materials and Methods: Study design: cross sectional. Setting: Tertiary care teaching and non-teaching hospitals and private laboratories. Data collection method: Knowledge, attitude and practices survey using a questionnaire. Results: Majority (90.5% of the respondents have had NSI in their total career. In the previous year, more than half (71.4% had at least one NSI (mean 3.2. NSI was the most common in index finger of non-dominant hand (59.6% and occurred during step two of FNA procedure when the needle was being manipulated within the lump. The major predisposing factors were uncooperative patients (88.9%, small children (54%, deep masses (36.5%, hot humid climate (88.9%, heavy workload (76.2% and poor administrative arrangement (54%. The adherence to standard precautions was not optimal (74.6%. None of them reported NSI to the authorities, nor investigated source patient or themselves. 82.5% of the respondents were not aware of any formal exposure reporting system in their hospital. Conclusion: Cytopathologists frequently experience NSI while performing FNA. Frequency of injury is also related to patient characteristics and work site factors. Education and motivation for adhering to standard precautions and post-exposure prophylaxis are often lacking.

  12. Survey of tritiated oil sources and handling practices

    International Nuclear Information System (INIS)

    Miller, J.M.

    1994-08-01

    Tritium interactions with oil sources (primarily associated with pumps) in tritium-handling facilities can lead to the incorporation of tritium in the oil and the production of tritiated hydrocarbons. This results in a source of radiological hazard and the need for special handling considerations during maintenance, decontamination, decommissioning and waste packaging and storage. The results of a general survey of tritiated-oil sources and their associated characteristics, handling practices, analysis techniques and waste treatment/storage methods are summarized here. Information was obtained from various tritium-handling laboratories, fusion devices, and CANDU plants. 38 refs., 1 fig

  13. Apparel Manufacturing (Course Outline), Industrial Single Needle Machines and Machine Practice: 9377.02.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This course includes a study of the industrial single needle machine, its principal parts, general care, threading, and basic skills in machine practice. Instructional materials include films, illustration, information sheets, and other materials. (CK)

  14. Safer handling practice: influence of staff education on older people.

    Science.gov (United States)

    Wilson, Christine Brown

    The purpose of this small-scale survey was to explore the level of moving and handling training undertaken by nurses within private sector continuing care environments and the potential this training had to influence the care of older people. This study uses a definition of safer handling practice derived from existing literature to examine how nurses report the application of this training and whether they observe changes to the mobility of older people within their care. The limitations of this study indicate that generalizations must be made cautiously. However, this study tentatively suggests that potential exists to influence positively the use of safer handling practice as defined within this study. Recommendations for further study are made.

  15. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to pierce the skin in the practice of acupuncture. The device consists of a solid, stainless steel needle. The...

  16. Milk postharvest handling practices across the supply chain in Eastern Ethiopia

    Directory of Open Access Journals (Sweden)

    Tadele Amentie

    2016-06-01

    Full Text Available Objective: This study was conducted to assess hygienic cow milk handling practices of milk producers, traders (informal collectors, transporters and vendors and consumers across the milk supply chain in the Eastern Ethiopia. Materials and methods: A total of 160 milk producers in Babile district were selected using multistage stratified sampling technique. Moreover, a total of 54 milk collectors and transporters (5, 40, 9 from Jigjiga, Harar and Dire Dawa town, respectively, 152 vendors (40 from Bable, Harar and Dire Dawa town and 32 from Jigjiga town and 160 consumers (40 from each town were selected using snowball sampling technique. Data from the selected actors were collected using focus group discussion, questionnaire survey and observations. Results: The study revealed that the majority of milk handling operations in the study area is carried out by females. The majority of respondent milk producers (87.5-92.5%, collectors and transporters (88.9-100%, vendors (77.5-90.7% and some consumers (37.5-47.5% performing milk handling operations were illiterate. Most of the observed actors in the study area perform malpractices (such as failure to stop milk handling while showing disease symptoms, improper hand washing and handling of risk factors while working with milk. Majority of respondent milk producers (87.5-97.5%, all traders and some consumers (12.5-32.5% use plastic containers for milk handling. Milk handling equipments were commonly washed using warm water, detergent and sand; however, in most case they were not properly protected from risk factors after washing. Majority of respondent milk producers (55-65%, collectors and transporters (60-66.7%, and some vendors (0-50% and consumers (0-55% use water from non-tap sources for hygienic practices. Conclusion: In general; the findings indicated that milk handling practices performed across the supply chain in the study area were unhygienic and therefore suggested the need for improving

  17. Factors affecting vaccine handling and storage practices among ...

    African Journals Online (AJOL)

    Objective: Assessing the factors associated with vaccine handling and storage practices. Methods: This was a .... Others include insufficient/unavailable backup refrigerators (52%) .... Human Vaccines 2010; 6(3): 270-278. 5. Joao Carlos de ...

  18. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  19. Public health implications of post-harvest fish handling practices in ...

    African Journals Online (AJOL)

    A wide range of handling practices for harvested fish exists and they have economic as well as public health implications. This paper is a review of the existing problems in fish handling technologies at post-harvest in Nigeria. The public health aspects with the associated implications are highlighted. Status of policy on fish ...

  20. Trabeculectomy bleb needling and antimetabolite administration practices in the UK: a glaucoma specialist national survey.

    Science.gov (United States)

    Mercieca, Karl; Drury, Brett; Bhargava, Archana; Fenerty, Cecilia

    2017-12-06

    To evaluate, describe and quantify the diversity in postoperative antimetabolite administration and bleb needling practices among glaucoma specialists performing trabeculectomy surgery within the UK and Ireland. A cross-sectional online survey was distributed to all consultant glaucoma specialists who are on the United Kingdom and Eire Glaucoma Society (UKEGS) contact list. Participants were asked specific questions about their current practices for post-trabeculectomy antimetabolite administration followed by questions directly related to bleb needling procedures. 60 (83%) of UKEGS glaucoma subspecialty consultants completed the survey. 70% of respondents administered 5-fluorouracil (5-FU) in their clinic room while 30% used a separate treatment room. Doses of 5-FU varied considerably but 70% used 5 mg as standard. Techniques used to reduce corneal toxicity included precipitation with amethocaine (44%) or benoxinate (14%), saline wash (14%) and modified injection technique (8%). Topical antibiotics and/or betadine were used to prevent infection following 5-FU injection in just over 50%. Bleb needling was exclusively performed in operating theatre by 56% of respondents and solely at the slit lamp in the clinic room by 12%. A further 30% used a combination of both theatre and outpatient clinic rooms. Anti-metabolites used were 5-FU (72%) and mitomycin C (22%) with 12% using either of the two substances. There is a significantly wide variety of current practices for antimetabolite administration and bleb needling within the UK and Ireland. This may be influenced by a glaucoma surgeon's specific experience and audit results as well as particular clinical set-up, availability of antimetabolite and clinic room space. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Regulation and practice of workers' protection from chemical exposures during container handling

    DEFF Research Database (Denmark)

    Nørgaard Fløe Pedersen, Randi; Jepsen, Jørgen Riis; Ádám, Balázs

    2014-01-01

    instructions relate to container handling, the provided information is not sufficiently detailed to conduct safe practice in many aspects. In accordance with the scientific literature, the interviewees estimate that there is a high frequency (5 to 50%) of containers with hazardous chemical exposure......Background: Fumigation of freight containers to prevent spread of pests and off-gassing of freight are sources of volatile chemicals that may constitute significant health risks when released. The aim of the study was to investigate the regulation and practice of container handling in Denmark...... with focus on preventive measures to reduce risk of chemical exposure. Methods: A comprehensive systematic search of scientific literature, legislation and recommendations related to safe work with transport containers from international and Danish regulatory bodies was performed. The practice of handling...

  2. A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver.

    Science.gov (United States)

    Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay

    2018-01-01

    The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.

  3. Influence of Handling Practices on Material Recovery from Residential Solid Waste

    Directory of Open Access Journals (Sweden)

    Jairo F. Pereira

    2010-07-01

    Full Text Available Material recovery from municipal solid waste (MSW is becoming widely adopted in several developing countries. Residential solid waste is one of the most important components of MSW and the handling practices of the MSW by the generators have a major impact on the quality and quantity of the materials for recovery. This article analyzes the generation and composition of residential solid waste and the handling practices by users in three municipalities in Colombia that have a solid waste management plant (SWMP. The findings show that, although there are significant amounts of useful materials, their handling of the materials as “garbage”, the low recognition of recovery work, and the inadequate storage and source management practices, affect material recovery and the operation of SWMPs. These results may be taken as a reference for this type of municipality, because the solid waste management system and the type of operation of the SWMPs analyzed is similar to all of the SWMPs in the country as well as in other countries in the region.

  4. Sheep pre-slaughter handling practices and their effect on meat quality

    Directory of Open Access Journals (Sweden)

    Francisco Gerardo Ríos-Rincón

    2013-06-01

    Full Text Available Aspects related to ovine production systems in Mexico were revisited, as well as the relationship between the transport and the ante-mortem handling with ovine welfare and pre slaughter operations. Animals stress evaluation is fundamental importance for this process, where the observation of animal behavior is basic to determinate and understands the scope of this biological phenomenon. Finally, we make reference to two of the main meat quality attributes that can be affected as consequence of non-appropriated handling practice and operations that implies the un-knowledge of animal conduct. The conclusion is that the handling practices previous to slaughter of ovine specie had a considerable influence on carcass quality. In Mexico is important to focus the cattle research on the productive systems improvement in consideration to animal welfare in the different productive process steps.

  5. Ground beef handling and cooking practices in restaurants in eight States.

    Science.gov (United States)

    Bogard, April K; Fuller, Candace C; Radke, Vincent; Selman, Carol A; Smith, Kirk E

    2013-12-01

    Eating in table-service restaurants has been implicated as a risk factor for Escherichia coli O157:H7 infection. To explore this association and learn about the prevalence of risky ground beef preparation practices in restaurants, the Environmental Health Specialists Network (EHS-Net) assessed ground beef handling policies and practices in restaurants in California, Colorado, Connecticut, Georgia, Minnesota, New York, Oregon, and Tennessee. Eligible restaurants prepared and served hamburgers. EHS-Net specialists interviewed a restaurant employee with authority over the kitchen (defined as the manager) using a standard questionnaire about food safety policies, hamburger preparation policies, and use of irradiated ground beef. Interviews were followed by observations of ground beef preparation. Data from 385 restaurants were analyzed: 67% of the restaurants were independently owned and 33% were chain restaurants; 75% of the restaurants were sit down, 19% were quick service or fast food, and 6% were cafeteria or buffet restaurants. Eighty-one percent of restaurants reported determining doneness of hamburgers by one or more subjective measures, and 49% reported that they never measure the final cook temperatures of hamburgers. At least two risky ground beef handling practices were observed in 53% of restaurants. Only 1% of restaurants reported purchasing irradiated ground beef, and 29% were unfamiliar with irradiated ground beef. Differences in risky ground beef handling policies and practices were noted for type of restaurant ownership (independently owned versus chain) and type of food service style (sit down versus quick service or fast food). This study revealed the pervasiveness of risky ground beef handling policies and practices in restaurants and the need for educational campaigns targeting food workers and managers. These results highlight the importance of continued efforts to reduce the prevalence of E. coli O157:H7 in ground beef.

  6. Modern power station practice mechanical boilers, fuel-, and ash-handling plant

    CERN Document Server

    Sherry, A; Cruddace, AE

    2014-01-01

    Modern Power Station Practice, Second Edition, Volume 2: Mechanical (Boilers, Fuel-, and Ash-Handling Plant) focuses on the design, manufacture and operation of boiler units and fuel-and ash-handling plants.This book is organized into five main topics-furnace and combustion equipment, steam and water circuits, ancillary plant and fittings, dust extraction and draught plant, and fuel-and ash-handling plant.In these topics, this text specifically discusses the influence of nature of coal on choice of firing equipment; oil-burner arrangements, ignition and control; disposition of the heating surf

  7. Food Handling Practices and Food Safety Messaging Preferences of African American and Latino Consumers

    Directory of Open Access Journals (Sweden)

    Emily Patten

    2018-02-01

    Full Text Available Extensive research on consumer food handling has identified common practices that could negatively impact food safety. Limited research has considered if food handling practices differ among diverse groups or if unique approaches are needed to provide food safety education for different audiences. This study examined food handling practice differences between African-American and Latino consumers and differing responses to food safety messages. Four focus groups were conducted, two with African-American participants and two with Latino participants, with each focus group consisting of 10-15 participants. Focus group transcripts were reviewed, coded, and grouped into themes using an iterative process. The 50 participants self-identified as either African-American or Latino, had home meal preparation experience, and were 18 years or older. Each focus group was multigenerational and included males and females. Risky food handling practices reported by both groups included rinsing poultry before cooking and limited food thermometer use. African-American participants preferred informational food safety messages, whereas Latino participants were split in preferring informational, guilt-inducing, and fear-inducing messages.

  8. A novel fabrication method of silicon nano-needles using MEMS TMAH etching techniques

    International Nuclear Information System (INIS)

    Yan Sheping; Xu Yang; Yang Junyi; Wang Huiquan; Jin Zhonghe; Wang Yuelin

    2011-01-01

    Nano-needles play important roles in nanoscale operations. However, current nano-needle fabrication is usually expensive and controling the sizes and angles is complicated. We have developed a simple and low cost silicon nano-needle fabrication method using traditional microelectromechanical system (MEMS) tetramethyl ammonium hydroxide (TMAH) etching techniques. We take advantage of the fact that the decrease of the silicon etch rate in TMAH solutions exhibits an inverse fourth power dependence on the boron doping concentration in our nano-needle fabrication. Silicon nano-needles, with high aspect ratio and sharp angles θ as small as 2.9 deg., are obtained, which could be used for bio-sensors and nano-handling procedures, such as penetrating living cells. An analytic model is proposed to explain the etching evolution of the experimental results, which is used to predict the needle angle, length, and etching time. Based on our method, nano-needles with small acute angle θ can be obtained.

  9. Patients’ Knowledge of and Practices Relating to the Disposal of Used Insulin Needles

    Directory of Open Access Journals (Sweden)

    Kerri T. Musselman, PharmD

    2010-01-01

    Full Text Available Objective: To determine (1 how patients currently dispose of used insulin needles, (2 whether patients were educated about disposal of their used insulin needles, and (3 who educated patients about the disposal of their used insulin needles.Methods: A self-administered questionnaire was designed for this study. The survey assessed patient knowledge about disposal of used insulin needles and the patient-reported source and location of education about disposal techniques. The questionnaire was administered to a convenience sample of patients from four locations in Richmond, Virginia. Any patient who used insulin, was at least 18 years old, and was willing to complete the survey was eligible for inclusion.Results: Fifty responses were received with 40% indicating that education had been received on the disposal of used needles. From that 40%, nurses were identified as the source of education 60% of the time and pharmacists 25% of the time. Approximately 50% of the respondents reported disposing of used needles directly in the trash when at home. While away from home, 22% reported placing used needles in the trash, and 38% took them home for disposal.Conclusion: Patients are not consistently educated regarding the proper disposal of used needles. Health care practitioners should play a larger role in educating patients about the potential risks of inappropriate needle disposal and appropriate disposal methods. Future research is still needed to understand fully the magnitude of the problems associated with inappropriate needle disposal by patients.

  10. Knowledge and Food Handling Practices of Nurses in a Tertiary Health Care Hospital in Nigeria.

    Science.gov (United States)

    Oludare, Aluko Olufemi; Ogundipe, Abiodun; Odunjo, Abimbola; Komolafe, Janet; Olatunji, Ibukun

    2016-01-01

    Food safety in hospitals is important to protect patients whose immunity may be compromised by their illness. The safety of food served to patients is dependent on its handling acquisition of raw food items, to preparation, packaging, and distribution. The study described in this article assessed the knowledge and food handling practices of nurses in the food chain to patients in the hospital wards. The mean age of respondents was 33.7 ± 9.3 years and 180 (56.6%) had worked in the hospital for 1-5 years. While respondents had good knowledge scores overall, only 22 (6.5%) knew the correct temperature for maintaining hot, ready-to-eat food. Also, 332 (97.6%) respondents knew the importance of hand washing before handling food while 279 (84.1%) always wash hands before handling food. The study revealed a decline in performance over time, from knowledge and attitudes to practice in food handling. Therefore, regular training on safe food handling procedures should be mainstreamed into the training curriculum of staff nurses in health care institutions.

  11. Air-handling energy efficiency and design practices

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Lars J.

    1993-12-31

    With good design practices and life-cycle cost optimization, specific fan power for individual fans will be between 0.5 and 1kW/m{sup 3}/s. Data from nearly 1000 audited fans in Sweden show that the average measured SFPI weighted by drawn motor power is 1.5 kW/m{sup 3}/s and the situation appears to be similar in other countries. Contract forms used by Swedish builders, and consultants` design practices are analyzed here to search for an explanation to the low performance of installed systems. Identified as two major barriers to efficient system design are the lack of performance specifications when procuring systems and the incentive structure in the building sector. As a consequence, duct design methods, rules of thumb, and vendor recommendations are not leading to system optimization. The broad minima in life cycle costs over a range of air-handling unit sizes show that potential economic welfare losses from efficiency standards are likely to be smaller than the losses that result from today`s design practices. 73 refs, 4 figs, 3 tabs

  12. Air-handling energy efficiency and design practices

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Lars J

    1994-12-31

    With good design practices and life-cycle cost optimization, specific fan power for individual fans will be between 0.5 and 1kW/m{sup 3}/s. Data from nearly 1000 audited fans in Sweden show that the average measured SFPI weighted by drawn motor power is 1.5 kW/m{sup 3}/s and the situation appears to be similar in other countries. Contract forms used by Swedish builders, and consultants` design practices are analyzed here to search for an explanation to the low performance of installed systems. Identified as two major barriers to efficient system design are the lack of performance specifications when procuring systems and the incentive structure in the building sector. As a consequence, duct design methods, rules of thumb, and vendor recommendations are not leading to system optimization. The broad minima in life cycle costs over a range of air-handling unit sizes show that potential economic welfare losses from efficiency standards are likely to be smaller than the losses that result from today`s design practices. 73 refs, 4 figs, 3 tabs

  13. Handling radioactivity: a practical approach for scientists and engineers

    International Nuclear Information System (INIS)

    Stewart, D.C.

    1981-01-01

    The aim of this book is to present an overall view in a descriptive and essentially nonmathematical way of the practicalities of handling radioactivity. It is hoped that the material will be particularly helpful to those entering the nuclear field for the first time and to those working in related areas whose responsibilities require them to have a general knowledge of the subject of radioactivity handling and its vocabulary. The presentation is primarily for bench-scale operations. There is a considerable emphasis on facilities since these are fundamental to the safe handling of active materials. Facility design and detail is also unfortunately an area where the relevant information is largely scattered through literature sources that are not accessible to most readers. Some of the topics surveyed - such as dosimetry, shielding and nuclear criticality - are extremely complex and no pretense is made that the treatment here represents more than bare bone summaries of the fields. A considerable effort has been made to cite the key references in each area where more detailed information can be found. A few additional useful references not cited directly in the text appear in an abbreviated bibliography at the end of the book

  14. NPIP: A skew line needle configuration optimization system for HDR brachytherapy

    International Nuclear Information System (INIS)

    Siauw, Timmy; Cunha, Adam; Berenson, Dmitry; Atamtürk, Alper; Hsu, I-Chow; Goldberg, Ken; Pouliot, Jean

    2012-01-01

    Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, δ. The candidate needle set consisted of 5000 needles, and a range of δ values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of δ values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer

  15. Factors affecting food handling Practices among food handlers of Dangila town food and drink establishments, North West Ethiopia

    Science.gov (United States)

    2014-01-01

    Background Food borne diseases are major health problems in developed and developing countries including Ethiopia. The problem is more noticeable in developing countries due to prevailing poor food handling and sanitation practices, inadequate food safety laws, weak regulatory systems, lack of financial resources to invest on safer equipments, and lack of education for food handlers. Methods The objective of this study was to assess food handling practice and associated factors among food handlers working in food and drinking establishments of Dangila town, North West Ethiopia. Cross-sectional quantitative study design was conducted among 406 food handlers working in 105 food and drink establishments from July to August 2013 in Dangila town. Data were collected using face to face interview with pretested structured questionnaire and physical observation. Result The mean age of the respondents was 22.7 ± 4.2 years of which 62.8% of the food handlers were females. Two hundred thirteen (52.5%) of food handlers had good food handling practices. Marital status (AOR = 7.52, 95% CI, 1.45-38.97), monthly income (AOR = 0.395, 95% CI, 0.25-0.62), knowledge about food handling (AOR = 1.69, 95% CI, 1.05-2.73), existence of shower facility (AOR = 1.89, 95% CI, 1.12-3.21) and separate dressing room (AOR = 1.97, 95% CI, 1.11-3.49) were found to be significantly associated with good food handling Practices. Conclusion Above half of food handlers had good food handling practices. Marital status, monthly income, knowledge status, existence of shower facility, existence of separate dressing room and presence of insect and rodent were factors associated with food handling Practices. PMID:24908104

  16. Risk of needle stick injuries in health care workers: bad habits (recapping needles) last long.

    Science.gov (United States)

    Rogowska-Szadkowska, Dorota; Stanisławowicz, Małgorzata; Chlabicz, Sławomir

    2010-01-01

    In order to assess the nurses' knowledge concerning the risk of hepatitis B and C viruses or human immunodeficiency virus infection while performing their professional duties, an anonymous questionnaire developed by the authors was distributed in 2008. Surprisingly 64% respondents occasionally recapping needles after injections, although they know the procedures which are obligatory at the ward. The first step in preventing percutaneous injuries should focus on efforts to eliminate the practice of recapping needles, though education and convenient placement of puncture-resistant containers for the disposal of used sharps.

  17. Prevalence and correlates of needle-stick injuries among active duty police officers in Tijuana, Mexico.

    Science.gov (United States)

    Mittal, María Luisa; Beletsky, Leo; Patiño, Efraín; Abramovitz, Daniela; Rocha, Teresita; Arredondo, Jaime; Bañuelos, Arnulfo; Rangel, Gudelia; Strathdee, Steffanie A

    2016-01-01

    Police officers are at an elevated risk for needle-stick injuries (NSI), which pose a serious and costly occupational health risk for HIV and viral hepatitis. However, research on NSIs among police officers is limited, especially in low- and middle-income countries. Despite the legality of syringe possession in Mexico, half of people who inject drugs (PWID) in Tijuana report extrajudicial syringe-related arrests and confiscation by police, which has been associated with needle-sharing and HIV infection. We assessed the prevalence and correlates of NSIs among Tijuana police officers to inform efforts to improve occupational safety and simultaneously reduce HIV risks among police and PWID. Tijuana's Department of Municipal Public Safety (SSPM) is among Mexico's largest. Our binational, multi-sectoral team analyzed de-identified data from SSPM's 2014 anonymous self-administered occupational health survey. The prevalence of NSI and syringe disposal practices was determined. Logistic regression with robust variance estimation via generalized estimating equations identified factors associated with ever having an occupational NSI. Approximately one-quarter of the Tijuana police force was given the occupational health survey (N=503). Respondents were predominantly male (86.5%) and ≤35 years old (42.6%). Nearly one in six officers reported ever having a NSI while working at SSPM (15.3%), of whom 14.3% reported a NSI within the past year. Most participants reported encountering needles/syringes while on duty (n=473, 94%); factors independently associated with elevated odds of NSIs included frequently finding syringes that contain drugs (adjusted odds ratio (AOR): 2.98; 95% confidence interval (CI): 1.56-5.67) and breaking used needles (AOR: 2.25; 95% CI: 1.29-3.91), while protective factors included being willing to contact emergency services in case of NSIs (AOR: 0.39; 95% CI: 0.22-0.69), and wearing needle-stick resistant gloves (AOR: 0.43; 95% CI: 0.19-0.91). Tijuana

  18. Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

    Science.gov (United States)

    Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M

    2017-12-01

    The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.

  19. Practice pattern of transthoracic needle biopsy: 2016 survey in the members of Korean society of thoracic radiology

    International Nuclear Information System (INIS)

    Jo, Ye Seul; Han, Kyong Min; Park, Jai Soung; Kim, Tae Jung

    2017-01-01

    To assess the current practice patterns of radiologists who perform transthoracic needle biopsy (TNB). An email survey of 71 questions on TNB was sent to 240 members of the Korean Society of Thoracic Radiology. The answers to multiple-choice questions (n = 56) were analyzed. Of 60 respondents, 45% had 10 or more years of experience in chest radiology, and 70% had 5 or more years of experience in TNB. For the question on the most frequently used diagnostic method for lesions with high probability of being resectable-stage lung cancer, 70% of respondents answered that TNB is initially used, with or without bronchoscopy. In patients at high-risk of TNB-related complications, the proportion of the respondents who consistently declined TNB was only 5%. The number of rebiopsies was said to be increased; molecular analysis for an established target therapy (43.6%) and clinical trial of a new drug (28.2%) were the two most common reasons for it. The most popular needle type was the coaxial cutting needle (55%), and the popular guiding modality was conventional computed tomography (CT) (56.7%). In addition, 15% of respondents have encountered air embolism. Despite high variation in how TNB is being performed in Korea, some patterns were noted. It is common for patients with resectable-stage lung cancer to undergo TNB prior to surgery. Rebiopsy is now more common than before, with personalized medicine as the most important reason for it. The most popular type of needle is the coaxial system; the most popular modality for guidance is still CT

  20. Practice pattern of transthoracic needle biopsy: 2016 survey in the members of Korean society of thoracic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Ye Seul [Dept. of Radiology, Incheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Incheon (Korea, Republic of); Han, Kyong Min [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Park, Jai Soung [Dept. of Radiology, Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Kim, Tae Jung [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-11-15

    To assess the current practice patterns of radiologists who perform transthoracic needle biopsy (TNB). An email survey of 71 questions on TNB was sent to 240 members of the Korean Society of Thoracic Radiology. The answers to multiple-choice questions (n = 56) were analyzed. Of 60 respondents, 45% had 10 or more years of experience in chest radiology, and 70% had 5 or more years of experience in TNB. For the question on the most frequently used diagnostic method for lesions with high probability of being resectable-stage lung cancer, 70% of respondents answered that TNB is initially used, with or without bronchoscopy. In patients at high-risk of TNB-related complications, the proportion of the respondents who consistently declined TNB was only 5%. The number of rebiopsies was said to be increased; molecular analysis for an established target therapy (43.6%) and clinical trial of a new drug (28.2%) were the two most common reasons for it. The most popular needle type was the coaxial cutting needle (55%), and the popular guiding modality was conventional computed tomography (CT) (56.7%). In addition, 15% of respondents have encountered air embolism. Despite high variation in how TNB is being performed in Korea, some patterns were noted. It is common for patients with resectable-stage lung cancer to undergo TNB prior to surgery. Rebiopsy is now more common than before, with personalized medicine as the most important reason for it. The most popular type of needle is the coaxial system; the most popular modality for guidance is still CT.

  1. Needle Decompression in Appalachia Do Obese Patients Need Longer Needles?

    Directory of Open Access Journals (Sweden)

    Carter, Thomas Edward

    2013-11-01

    Full Text Available Introduction: Needle decompression of a tension pneumothorax can be a lifesaving procedure. It requires an adequate needle length to reach the chest wall to rapidly remove air. With adult obesity exceeding one third of the United States population in 2010, we sought to evaluate the proper catheter length that may result in a successful needle decompression procedure. Advance Trauma Life Support (ATLS currently recommends a 51 millimeter (mm needle, while the needles stocked in our emergency department are 46 mm. Given the obesity rates of our patient population, we hypothesize these needles would not have a tolerable success rate of 90%. Methods: We retrospectively reviewed 91 patient records that had computed tomography of the chest and measured the chest wall depth at the second intercostal space bilaterally. Results: We found that 46 mm needles would only be successful in 52.7% of our patient population, yet the ATLS recommended length of 51 mm has a success rate of 64.8%. Therefore, using a 64 mm needle would be successful in 79% percent of our patient population. Conclusion: Use of longer length needles for needle thoracostomy is essential given the extent of the nation’s adult obesity population. [West J Emerg Med. 2013;14(6:650-652.

  2. Reduced variability and execution time to reach a target with a needle GPS system: Comparison between physicians, residents and nurse anaesthetists.

    Science.gov (United States)

    Fevre, Marie-Cécile; Vincent, Caroline; Picard, Julien; Vighetti, Arnaud; Chapuis, Claire; Detavernier, Maxime; Allenet, Benoît; Payen, Jean-François; Bosson, Jean-Luc; Albaladejo, Pierre

    2018-02-01

    Ultrasound (US) guided needle positioning is safer than anatomical landmark techniques for central venous access. Hand-eye coordination and execution time depend on the professional's ability, previous training and personal skills. Needle guidance positioning systems (GPS) may theoretically reduce execution time and facilitate needle positioning in specific targets, thus improving patient comfort and safety. Three groups of healthcare professionals (41 anaesthesiologists and intensivists, 41 residents in anaesthesiology and intensive care, 39 nurse anaesthetists) were included and required to perform 3 tasks (positioning the tip of a needle in three different targets in a silicon phantom) by using successively a conventional US-guided needle positioning and a needle GPS. We measured execution times to perform the tasks, hand-eye coordination and the number of repositioning occurrences or errors in handling the needle or the probe. Without the GPS system, we observed a significant inter-individual difference for execution time (Pgaming were found to be independent factors associated with a shorter execution time. Use of GPS attenuated the inter-individual and group variability. We observed a reduced execution time and improved hand-eye coordination in all groups as compared to US without GPS. Neither US training, video gaming nor demographic personal or professional factors were found to be significantly associated with reduced execution time when GPS was used. US associated with GPS systems may improve safety and decrease execution time by reducing inter-individual variability between professionals for needle-handling procedures. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  3. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  4. [Professor Feng Run-Shen's essential experience in penetration needling method].

    Science.gov (United States)

    Feng, Mu-Lan

    2009-04-01

    Professor Feng Run-Shen is engaged in medicine for more than 60 years. He pays attention to medical ethics and has perfect medical skill. He energetically advocates combination of acupuncture with medication and stresses the concept of viewing the situation as a whole in selection of acupoints and treatment, particularly, clinical application of point properties. Clinically, he is accomplished in penetration needling, for which one needle acts on two or more points, enlarging the range of needling sensation, so it has very good therapeutic effects on many diseases. In the paper, the case samples about penetration needling in his clinical practice are summarized and introduced.

  5. Gender difference in safe and unsafe practice of pesticide handling in tobacco farmers of malaysia.

    Science.gov (United States)

    Bin Nordin, R; Araki, S; Sato, H; Yokoyama, K; Bin Wan Muda, W A; Win Kyi, D

    2001-01-01

    To identify gender difference in safe and unsafe practice of pesticide handling in tobacco farmers of Malaysia, we conducted a 20-item questionnaire interview on storage of pesticide (4 questions), mixing of pesticide (3 questions), use of personal protective equipment and clothing while spraying pesticide (7 questions), activities during and after spraying of pesticide (5 questions), and maintenance of pesticide sprayer (1 question) in 496 tobacco farmers (395 males and 101 females) in Bachok District, Kelantan, Malaysia. Duration of employment was significantly longer in females than those in males (pwork habit, (3) reading and following instructions on pesticide label, (4) security, storage and disposal of pesticide container, (5) safe work habit, (6) proper handling of pesticide and maintenance of pesticide sprayer, (7) use of personal protective clothing, and (8) safe handling of pesticide. Results of analysis of covariance for the eight factor scores of all male and female farmers, controlling for educational level and duration of employment, showed that: (1) factor scores for use of personal protective equipment (pwork habit (p0.05). We therefore conclude that: (1) for female tobacco farmers, choice of personal attire tend to result in lower scores on use of personal protective equipment and personal protective clothing while personal hygiene practices result in lower score on safe work habit; and, (2) for male tobacco farmers, the lower scores on reading and following instruction on pesticide label and mixing pesticide and maintenance of pesticide sprayer in good condition suggests that they were not primarily involved in these activities. It is postulated that these differences in safe and unsafe practices of pesticide handling across gender is related to the choice of personal attire, personal hygiene practices and division of labour within farming households which in turn is influenced by prevailing sociocultural norms in the community.

  6. Handling of bulk solids theory and practice

    CERN Document Server

    Shamlou, P A

    1990-01-01

    Handling of Bulk Solids provides a comprehensive discussion of the field of solids flow and handling in the process industries. Presentation of the subject follows classical lines of separate discussions for each topic, so each chapter is self-contained and can be read on its own. Topics discussed include bulk solids flow and handling properties; pressure profiles in bulk solids storage vessels; the design of storage silos for reliable discharge of bulk materials; gravity flow of particulate materials from storage vessels; pneumatic transportation of bulk solids; and the hazards of solid-mater

  7. Consumer Shell Egg Consumption and Handling Practices: Results from a National Survey.

    Science.gov (United States)

    Kosa, Katherine M; Cates, Sheryl C; Bradley, Samantha; Godwin, Sandria; Chambers, Delores

    2015-07-01

    Numerous cases and outbreaks of Salmonella infection are attributable to shell eggs each year in the United States. Safe handling and consumption of shell eggs at home can help reduce foodborne illness attributable to shell eggs. A nationally representative Web survey of 1,504 U.S. adult grocery shoppers was conducted to describe consumer handling practices and consumption of shell eggs at home. Based on self-reported survey data, most respondents purchase shell eggs from a grocery store (89.5%), and these eggs were kept refrigerated (not at room temperature; 98.5%). As recommended, most consumers stored shell eggs in the refrigerator (99%) for no more than 3 to 5 weeks (97.6%). After cracking eggs, 48.1% of respondents washed their hands with soap and water. More than half of respondents who fry and/or poach eggs cooked them so that the whites and/or the yolks were still soft or runny, a potentially unsafe practice. Among respondents who owned a food thermometer (62.0%), only 5.2% used it to check the doneness of baked egg dishes when they prepared such a dish. Consumers generally followed two of the four core "Safe Food Families" food safety messages ("separate" and "chill") when handling shell eggs at home. To prevent Salmonella infection associated with shell eggs, consumers should improve their practices related to the messages "clean" (i.e., wash hands after cracking eggs) and "cook" (i.e., cook until yolks and whites are firm and use a food thermometer to check doneness of baked egg dishes) when preparing shell eggs at home. These findings will be used to inform the development of science-based consumer education materials that can help reduce foodborne illness from Salmonella infection.

  8. Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?

    Science.gov (United States)

    Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M

    2009-01-01

    Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.

  9. Safe meat-handling knowledge, attitudes and practices of private and government meat processing plants' workers: implications for future policy.

    Science.gov (United States)

    Adesokan, H K; Raji, A O Q

    2014-03-01

    Food-borne disease outbreaks remain a major global health challenge and cross-contamination from raw meat due to poor handling is a major cause in developing countries. Adequate knowledge of meat handlers is important in limiting these outbreaks. This study evaluated and compared the safe meat-handling knowledge, attitudes and practices (KAP) of private (PMPP) and government meat processing plants' (GMPP) workers in south-western Nigeria. This cross sectional study comprised 190 meat handlers (PMPP = 55; GMPP = 135). Data concerning their safe meat-handling knowledge, attitudes and practices as well as their socio-demographic characteristics, such as age, gender and work experience were collected. A significant association was observed between the type of meat processing plants and their knowledge (p = 0.000), attitudes (p = 0.000) and practices (p = 0.000) of safe meat-handling. Meat handlers in the GMPP were respectively, about 17 times (OR = 0.060, 95% CI: 0.018-0.203), 57 times (OR = 0.019, 95% CI: 0.007-0.054) and 111 times (OR = 0.009, 95% CI: 0.001- 0.067) less likely to obtain good knowledge, attitude and practice level of safe meat-handling than those from PMPP. Further, KAP levels were significantly associated with age group, education and work experience (p < 0.05). Study findings suggest the need for future policy in food industry in developing countries to accommodate increased involvement of private sector for improved food safety and quality delivery. Public health education on safe food handling and hygiene should be on the front burner among food handlers in general.

  10. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  11. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  12. RFA-cut: Semi-automatic segmentation of radiofrequency ablation zones with and without needles via optimal s-t-cuts.

    Science.gov (United States)

    Egger, Jan; Busse, Harald; Brandmaier, Philipp; Seider, Daniel; Gawlitza, Matthias; Strocka, Steffen; Voglreiter, Philip; Dokter, Mark; Hofmann, Michael; Kainz, Bernhard; Chen, Xiaojun; Hann, Alexander; Boechat, Pedro; Yu, Wei; Freisleben, Bernd; Alhonnoro, Tuomas; Pollari, Mika; Moche, Michael; Schmalstieg, Dieter

    2015-01-01

    In this contribution, we present a semi-automatic segmentation algorithm for radiofrequency ablation (RFA) zones via optimal s-t-cuts. Our interactive graph-based approach builds upon a polyhedron to construct the graph and was specifically designed for computed tomography (CT) acquisitions from patients that had RFA treatments of Hepatocellular Carcinomas (HCC). For evaluation, we used twelve post-interventional CT datasets from the clinical routine and as evaluation metric we utilized the Dice Similarity Coefficient (DSC), which is commonly accepted for judging computer aided medical segmentation tasks. Compared with pure manual slice-by-slice expert segmentations from interventional radiologists, we were able to achieve a DSC of about eighty percent, which is sufficient for our clinical needs. Moreover, our approach was able to handle images containing (DSC=75.9%) and not containing (78.1%) the RFA needles still in place. Additionally, we found no statistically significant difference (p<;0.423) between the segmentation results of the subgroups for a Mann-Whitney test. Finally, to the best of our knowledge, this is the first time a segmentation approach for CT scans including the RFA needles is reported and we show why another state-of-the-art segmentation method fails for these cases. Intraoperative scans including an RFA probe are very critical in the clinical practice and need a very careful segmentation and inspection to avoid under-treatment, which may result in tumor recurrence (up to 40%). If the decision can be made during the intervention, an additional ablation can be performed without removing the entire needle. This decreases the patient stress and associated risks and costs of a separate intervention at a later date. Ultimately, the segmented ablation zone containing the RFA needle can be used for a precise ablation simulation as the real needle position is known.

  13. [Discussion on needling sensation, arrival of qi and needling response (Deqi)].

    Science.gov (United States)

    Zhang, Fang; Wang, Hong-Du

    2012-12-01

    The current appointed teaching material of Science of Acupuncture and Moxibustion holds that there is no difference among the needling sensation, arrival of qi and needling response. However, the author has a different understanding. Therefore, Neijing (Internal Classic), its annotation, exposition and understandings of ancient and modern famous experts are cited to analyze their meanings. And the result indicates that the needling sensation is subjective feelings and perceived responses of doctors and patients. Arrival of qi is the healing process of the organ through activating the anti-pathogenic qi to expel the pathogens. The needling response is the final aim of acupuncture therapy. Thus, the meaning of needling sensation, arrival of qi, and needling response are different. And an accurate understanding can better guide acupuncture treatment.

  14. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  15. A study of needle stick injuries among non-consultant hospital doctors in Ireland.

    LENUS (Irish Health Repository)

    O'Connor, M B

    2012-02-01

    INTRODUCTION: NCHDs are exposed to a great number of blood-borne infections. Needle stick injuries are possibly the main route of acquiring such infections from a non-consultant hospital doctors (NCHDs) perspective. This study examines NCHDs experiences surrounding needle stick injuries. METHODS: A cross-sectional self-administered anonymous questionnaire survey was conducted on 185 NCHDs working in a clinical setting among seven teaching hospitals in Ireland. Implied consent was obtained. The data was analysed using Excel spreadsheets. Ethical approval was received. RESULTS: A response rate of 85.4% (158\\/185) was achieved. Findings of the study are shown in the manuscript table. CONCLUSIONS: A needle stick injury (NI) history is greater among surgical NCHDs than medical NCHDs. The level of disposable glove usage is worryingly poor. Training in sharps handling and dealing with a NI needs to be addressed. HIV is the blood-borne infection most fear of being contracting as a consequence of a NI.

  16. Relations between Scots pine needle element concentrations and decreased needle longevity along pollution gradients

    International Nuclear Information System (INIS)

    Lamppu, Jukka; Huttunen, Satu

    2003-01-01

    Deceased needle longevity was related to increased heavy metal concentrations. - Scots pine (Pinus sylvestris L.) shoots were sampled along transects near one urban pollution source and two smelters. Needle Mg, P and K concentrations decreased from the second to the fourth age class linearly with needle survival along the urban pollution gradient. Still, over 80% of the average concentration of these nutrients remained in the fourth needle age class. Decreased needle longevity was closely related to the increased heavy metal concentrations near the smelters. Near the urban pollution source, it was related to the increased annual needle mass and the increased needle nutrient concentrations. Decreased Mn accumulation along with needle age was detected near all pollution sources. Leaching of Mn from needles and especially from soil as a cause of decreased needle concentrations is discussed

  17. Chemotherapy drug handling in first opinion small animal veterinary practices in the United Kingdom: results of a questionnaire survey.

    Science.gov (United States)

    Edery, E G

    2017-05-27

    To investigate how first opinion small animal veterinary surgeons in the UK handled chemotherapeutic agents, a questionnaire was distributed at the 2014 British Small Animal Veterinary Association congress and by internet. Chemotherapy was regularly offered by 70.4 per cent of the respondents. Gold standards defined according to available guidelines for safe handling of antineoplastic drugs were poorly followed by general practitioners with only 2 per cent of respondents complying with all of them. Dedicated facilities for preparation and administration of cytotoxic drugs were variably available among participants. The level of training of staff indirectly involved in handling chemotherapy was appropriate in less than 50 per cent of practices. No association was found between demographic characteristics of the sampled population and the decision to perform chemotherapy. The results of this study raise concerns about the safety of the veterinary staff in first opinion practices involved in handling chemotherapy. British Veterinary Association.

  18. Determination of metals in scots pine (Pinus Sylvestris) needles and soil samples

    International Nuclear Information System (INIS)

    Ludborzs, A.; Viksna, A.

    2000-01-01

    Current report is the finding to apply two modern and powerful methods of microanalysis - Total Reflection X-ray Fluorescence Spectrometry (TXRF) and Graphite Furnace Atomic Absorption Spectrometry - for the analysis of biological and geological materials. For some of the measurements Instrumental Neutron Activation Analysis (INAA) has been used as an arbitrary method. The goal of the research project is to find possible relationships between metals content in the Scots pine (Pinus sylvestris) needles and the soil samples, which have been taken under the trees. The objectives of the work are analysis of both needles and soils, pH measurements of the soil samples, and handling of a simplified metal speciation analysis in the soil samples. For statistical reliability of the project, seven pine trees from different locations in Latvia have been chosen as the analysis objects. Samples of 20 different age class needles have been collected from the trees and 21 soil sample has been sampled under the trees. K, Ca, Mn, Fe, Zn, Rb, Sr, Pb, and Cd content have been analysed in both samples of the needles and the soils. The obtained measurement data have been processed according to the aim of the project. Relevant questions about causal differences of metal concentrations in different age classes of needles, about subtle working principles of the plant's root system, about the role of some elements in the plant's living processes still remain unanswered. (author)

  19. Minor corral changes and adoption of good handling practices can improve the behavior and reduce cortisol release in Nellore cows.

    Science.gov (United States)

    Lima, Maria Lúcia Pereira; Negrão, João Alberto; de Paz, Claudia Cristina Paro; Grandin, Temple

    2018-03-01

    Inadequate corral facilities and improper handling are major causes of stress in beef cattle. The purpose of this study was to evaluate the effects of minor changes in the corral and adoption of good handling practices on the behavior, cortisol release, and time spent taking blood samples in Nellore cows. Minor corral changes included obstructing the cow's vision when the handler walked deep into the animal's flight zone and the elimination of bright objects, color contrasts, puddles, shadows, and darkness in the corral. Handling was improved by eliminating dogs, electric goads (prods), and yelling, as well as adopting a calm behavior. A total of 141 Nellore cows from two typical extensive livestock farms were studied. The cows were evaluated individually before and after the corral changes. Blood samples were collected in the restraint device for cortisol measurement. The minor corral changes and the adoption of good handling practices result in better results for all variables studied. The results showed differences in the interactions between treatment and ranch for chute score (P = 0.0091) and exit score (P good handling practices were effective in improving cow behavior in the chute and in reducing exit velocity, cortisol released, and the time spent taking blood samples.

  20. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    Science.gov (United States)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  1. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  2. Development of Safe Food Handling Guidelines for Korean Consumers.

    Science.gov (United States)

    Kang, Hee-Jin; Lee, Min-Woo; Hwang, In-Kyeong; Kim, Jeong-Weon

    2015-08-01

    The purpose of this study was to develop guidelines for Korean consumers with regard to safe food handling practices at home by identifying current food handling issues. Korean consumers' behaviors regarding their safe food handling were identified via survey questionnaires that included items on individual hygiene practices, prepreparation steps when cooking, the cooking process, and the storage of leftover foods. The subjects were 417 Korean parents with elementary school children living in Seoul and Gyeonggi Province in the central area of Korea. The survey results revealed gaps between the knowledge or practices of Korean consumers and scientific evidence pertaining to safe food handling practices. Based on these findings, a leaflet on safe food handling guidelines was developed in accordance with Korean food culture. These guidelines suggest personal hygiene practices as well as fundamental principles and procedures for safe food handling from the stage of food purchase to that of keeping leftover dishes. A pilot application study with 50 consumers revealed that the guidelines effectively improved Korean consumers' safe food handling practices, suggesting that they can serve as practical educational material suitable for Korean consumers.

  3. Microbiological Safety and Food Handling Practices of Seed Sprout Products in the Australian State of Victoria.

    Science.gov (United States)

    Symes, Sally; Goldsmith, Paul; Haines, Heather

    2015-07-01

    Seed sprouts have been implicated as vehicles for numerous foodborne outbreaks worldwide. Seed sprouts pose a unique food safety concern because of the ease of microbiological seed contamination, the inherent ability of the sprouting process to support microbial growth, and their consumption either raw or lightly cooked. To examine seed sprout safety in the Australian state of Victoria, a survey was conducted to detect specific microbes in seed sprout samples and to investigate food handling practices relating to seed sprouts. A total of 298 seed sprout samples were collected from across 33 local council areas. Escherichia coli was detected in 14.8%, Listeria spp. in 12.3%, and Listeria monocytogenes in 1.3% of samples analyzed. Salmonella spp. were not detected in any of the samples. A range of seed sprout handling practices were identified as potential food safety issues in some food businesses, including temperature control, washing practices, length of storage, and storage in proximity to unpackaged ready-to-eat potentially hazardous foods.

  4. Injecting drug use in prison: prevalence and implications for needle exchange policy.

    Science.gov (United States)

    Wright, Nat M J; Tompkins, Charlotte N E; Farragher, Tracey M

    2015-01-01

    The purpose of this paper is to explore prison drug injecting prevalence, identify any changes in injecting prevalence and practice during imprisonment and explore views on prison needle exchange. An empirical prospective cohort survey conducted between 2006 and 2008. The study involved a random sample of 267 remand and sentenced prisoners from a large male category B prison in England where no prison needle exchange operates. Questionnaires were administered with prisoners on reception and, where possible, at one, three and six months during their sentence. In total, 64 per cent were injecting until admission into prison. The majority intended to stop injecting in prison (93 per cent), almost a quarter due to the lack of needle exchange (23 per cent). Yet when hypothetically asked if they would continue injecting in prison if needle exchange was freely available, a third of participants (33 per cent) believed that they would. Injecting cessation happened on prison entry and appeared to be maintained during the sentence. Not providing sterile needles may increase risks associated with injecting for prisoners who continue to inject. However, providing such equipment may prolong injecting for other prisoners who currently cease injecting on account of needle exchange programmes (NEPs) not being provided in the UK prison setting. Practical implications - Not providing sterile needles may increase risks associated with injecting for prisoners who continue to inject. However, providing such equipment may prolong injecting for other prisoners who currently cease injecting on account of NEPs not being provided in the UK prison setting. This survey is the first to question specifically regarding the timing of injecting cessation amongst male prisoners and explore alongside intention to inject should needle exchange facilities be provided in prison.

  5. The role of informal dimensions of safety in high-volume organisational routines: an ethnographic study of test results handling in UK general practice.

    Science.gov (United States)

    Grant, Suzanne; Checkland, Katherine; Bowie, Paul; Guthrie, Bruce

    2017-04-27

    The handling of laboratory, imaging and other test results in UK general practice is a high-volume organisational routine that is both complex and high risk. Previous research in this area has focused on errors and harm, but a complementary approach is to better understand how safety is achieved in everyday practice. This paper ethnographically examines the role of informal dimensions of test results handling routines in the achievement of safety in UK general practice and how these findings can best be developed for wider application by policymakers and practitioners. Non-participant observation was conducted of high-volume organisational routines across eight UK general practices with diverse organisational characteristics. Sixty-two semi-structured interviews were also conducted with the key practice staff alongside the analysis of relevant documents. While formal results handling routines were described similarly across the eight study practices, the everyday structure of how the routine should be enacted in practice was informally understood. Results handling safety took a range of local forms depending on how different aspects of safety were prioritised, with practices varying in terms of how they balanced thoroughness (i.e. ensuring the high-quality management of results by the most appropriate clinician) and efficiency (i.e. timely management of results) depending on a range of factors (e.g. practice history, team composition). Each approach adopted created its own potential risks, with demands for thoroughness reducing productivity and demands for efficiency reducing handling quality. Irrespective of the practice-level approach adopted, staff also regularly varied what they did for individual patients depending on the specific context (e.g. type of result, patient circumstances). General practices variably prioritised a legitimate range of results handling safety processes and outcomes, each with differing strengths and trade-offs. Future safety

  6. Evaluation of the Implementation of Good Handling Practices in Food and Beverage Areas of Hotels.

    Science.gov (United States)

    Serafim, A L; Hecktheuer, L H R; Stangarlin-Fiori, L; Medeiros, L B; Martello, L; Machado, C E

    2015-11-01

    Because of the major international-level events that have recently been held in Brazil, concerns about the sensory and hygienic-sanitary conditions of food have increased. The objective of this study was to evaluate the implementation of good handling practices in food and beverage areas of hotels, with and without outsourced professional intervention. We evaluated 19 food and beverage areas in hotels in Porto Alegre, Rio do Sul, Brazil, using a checklist that was developed by a municipal surveillance team based on existing laws for good handling practices. The evaluation was done by a skilled professional in the food safety area on two occasions, at the beginning of the study (January to May 2013) and at the end (July to November 2014), and the establishments were classified as good, regular, or poor. After the baseline evaluation, an action plan listing the noncompliance found at each location was given to those responsible for the establishments, and a period of 1 year 6 months was stipulated for improvements to be made. In the repeat evaluation, those responsible for the establishments were asked whether they had hired an outsourced professional to assist them in the improvements. The hotels showed improvement during the repeat evaluation, but a significant increase in the percentage of overall adequacy was seen only in the food and beverages areas of the 12 hotels that used the intervention of an outsourced professional. The better percentage of adequacy in establishments with outsourced professional intervention underlines the importance of an external and impartial view of routine activities in the implementation of good handling practices.

  7. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site) on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Science.gov (United States)

    Loyeung, Bertrand Y. K.; Cobbin, Deirdre M.

    2013-01-01

    Introduction. In traditional Chinese acupuncture, needle sensation (deqi) is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP) on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP) maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site. PMID:24159337

  8. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Topal, U.; Berkman, Yahya M.

    2005-01-01

    Purpose: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. Materials and methods: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by χ 2 test. Results: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P 0.05). Conclusion: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax

  9. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  10. A novel needle-type sampling device for flexible ultrathin bronchoscopy

    International Nuclear Information System (INIS)

    Suda, Yuji; Hayashi, Katsutoshi; Shindoh, Yuriko; Iijima, Hideya; Tanaka, Akiko

    2008-01-01

    Diagnosis of suspected cancer in the periphery of the lung is difficult. A flexible ultrathin bronchoscope has been developed for the diagnosis of peripherally located pulmonary lesions that cannot be reached with the sampling devices for standard flexible bronchoscopes. The diagnostic yield with forceps and a brush for ultrathin bronchoscopes, however, is not adequate, especially when a lesion is not exposed to the bronchial lumen. We have thus developed a novel needle-type sampling device and tested its yield in transbronchial cytology. The device consists of an elongated dental H-file (0.4 mm in diameter and 110 cm in length), a housing sheath (1.0 mm in outer diameter), and a novel handle, which enables rapid out-and-in motion of the needle. Ten consecutive patients with a peripheral pulmonary lesion who had an indication for diagnostic procedure with a flexible ultrathin bronchoscope were enrolled. The optimal bronchial route to the lesion was analyzed with virtual bronchoscopy in a data set obtained with high-resolution computed tomography, and a novel bronchial route labeling system (prior-ridge-based relative orientation nomenclature) was employed to guide insertion of the bronchoscope. Sampling with the novel needle was performed prior to use of the forceps and brush under conventional fluoroscopy. In all the cases, sampling with the needle was successful and the amount of the specimen was sufficient for cytology. Our novel sampling system with flexible ultrathin bronchoscopes may contribute to accurate and minimally invasive diagnosis of peripheral pulmonary lesions. (author)

  11. The intravenous injection of illicit drugs and needle sharing: an historical perspective.

    Science.gov (United States)

    Zule, W A; Vogtsberger, K N; Desmond, D P

    1997-01-01

    This study reviewed the literature on the history of needle sharing and intravenous drug abuse. Reports suggest that needle sharing was practiced by drug abusers as early as 1902 in China and 1914 in the United States. Intravenous drug abuse was first mentioned in the literature in 1925. However other references suggest that some opioid users were injecting intravenously prior to 1920. Outbreaks of malaria in Egypt, the United States, and China between 1929 and 1937 were attributed to needle sharing and intravenous injection of opioids. These reports suggest that both needle sharing and intravenous drug use were common by 1937. Factors such as medical use of intravenous injections, enactment and zealous enforcement of antinarcotic laws, and interactions among drug users in institutional settings such as regional hospitals and prisons may have contributed to the spread of both needle sharing and the intravenous technique among drug abusers.

  12. A practical guide to handling laser diode beams

    CERN Document Server

    Sun, Haiyin

    2015-01-01

    This book offers the reader a practical guide to the control and characterization of laser diode beams.  Laser diodes are the most widely used lasers, accounting for 50% of the global laser market.  Correct handling of laser diode beams is the key to the successful use of laser diodes, and this requires an in-depth understanding of their unique properties. Following a short introduction to the working principles of laser diodes, the book describes the basics of laser diode beams and beam propagation, including Zemax modeling of a Gaussian beam propagating through a lens.  The core of the book is concerned with laser diode beam manipulations: collimating and focusing, circularization and astigmatism correction, coupling into a single mode optical fiber, diffractive optics and beam shaping, and manipulation of multi transverse mode beams.  The final chapter of the book covers beam characterization methods, describing the measurement of spatial and spectral properties, including wavelength and linewidth meas...

  13. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  14. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  16. A change management approach to improving safety and preventing needle stick injuries.

    Science.gov (United States)

    Aziz, Ann-Marie

    2017-09-01

    Key drivers for preventing healthcare-associated infection (HCAI) include evidence-based practices and procedures that prevent infection. Among the current guidance for preventing HCAIs is evidence and mandatory requirements for reducing needle stick injuries (NSIs). This article highlights how John Kotter's model for change could help healthcare workers plan for successful and sustained deployment of needle safety devices (NSDs) and ultimately reduce the risk of a NSI.

  17. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  18. Survey of postharvest handling, preservation and processing ...

    African Journals Online (AJOL)

    Survey of postharvest handling, preservation and processing practices along the camel milk chain in Isiolo district, Kenya. ... Despite the important contribution of camel milk to food security for pastoralists in Kenya, little is known about the postharvest handling, preservation and processing practices. In this study, existing ...

  19. Review: Lyn Richards (2005. Handling Qualitative Data: A Practical Guide

    Directory of Open Access Journals (Sweden)

    Robert L. Miller

    2006-03-01

    Full Text Available Handling Qualitative Data: A Practical Guide is an introductory textbook covering all stages of qualitative research from the initial conceptualisation of a project, through data collection and analysis, to writing up. The author, Lyn RICHARDS, is a well-known developer of two key qualitative software analysis packages, NUD*IST and NVivo. While RICHARDS clearly advocates the use of qualitative analysis software, the text is "generic" and could be used in tandem with any qualitative software package. The book concentrates on practical advice about the use of software to manage and analyse qualitative data, and provides insights in these areas. The consideration of issues around team-based qualitative research is another strong point. However, due in part to its short length, the overall coverage of topics tends to be superficial. In itself, the book does not provide sufficient detailed support for a student who would like to use it as her/his main source of guidance for carrying out a qualitative research project. URN: urn:nbn:de:0114-fqs0602244

  20. Uranium hexafluoride: A manual of good handling practices

    International Nuclear Information System (INIS)

    1991-10-01

    For many years, the US Department of Energy (DOE) and its predecessor agencies have shared with the nuclear industry their experience in the area of uranium hexafluoride (UF 6 ) shipping containers and handling procedures. The information contained in this manual updates information contained in earlier issues. It covers the essential aspects of UF 6 handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF 6 are also described and tabulated. The nuclear industry is responsible for furnishing its own shipping cylinders and suitable protective overpacks. A substantial effort has been made by the industry to standardize UF 6 cylinders, samples, and overpacks. The quality of feed materials is important to the safe and efficient operation of the enriching facilities, and the UF 6 product purity from the enriching facilities is equally important to the fuel fabricator, the utilities, the operators of research reactors, and other users. The requirements have been the impetus for an aggressive effort by DOE and its contractors to develop accurate techniques for sampling and for chemical and isotopic analysis. A quality control program is maintained within the DOE enriching facilities to ensure that the proper degree of accuracy and precision are obtained for all the required measurements. The procedures and systems described for safe handling of UF 6 presented in this document have been developed and evaluated in DOE facilities during more than 40 years of handling vast quantities of UF 6 . With proper consideration for its nuclear properties, UF 6 may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical

  1. Uranium hexafluoride: A manual of good handling practices. Revision 7

    International Nuclear Information System (INIS)

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF 6 ) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF 6 handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF 6 handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF 6 are also described. The procedures and systems described for safe handling of UF 6 presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF 6 . With proper consideration for its nuclear properties, UF 6 may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical

  2. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  3. Survey of domestic food handling practices in New Zealand.

    Science.gov (United States)

    Gilbert, S E; Whyte, R; Bayne, G; Paulin, S M; Lake, R J; van der Logt, P

    2007-07-15

    The purpose of this survey was to obtain information on the domestic meat and poultry handling practices of New Zealanders in order to support the development of quantitative risk models, as well as providing data to underpin food safety campaigns to consumers. A sample of 1000 New Zealand residents, over 18 years of age, were randomly selected from the electoral roll and asked to participate in a national postal food safety study during 2005. Three hundred and twenty six respondents completed and returned questionnaires containing usable answers, and most of these respondents 'always' prepared the main meal within the household. The majority of meat (84.6%) and poultry (62.9%) purchased by New Zealanders was fresh (rather than frozen), and most consumers (94.4%) claimed that the time taken from food selection to reaching their home was 1 h or less. The majority (approximately 64%) of fresh meat and poultry was frozen in the home and the most favoured method of thawing was at room temperature for up to 12 h. The most common time period for storing cooked or raw meat and poultry in domestic refrigerators was up to 2 days. Most survey respondents preferred their meat and poultry to be cooked either medium or well done. The most popular cooking method for chicken was roasting or baking, while most respondents preferred to pan-fry steak/beef cuts, minced beef or sausages/hamburgers. The potential for undercooking was greatest with pan-fried steak with 19.8% of respondents preferring to consume this meat raw or rare. In answer to questions relating to food handling hygiene practices, 52.2% of respondents selected a hand washing sequence that would help prevent cross contamination. However, it was estimated that 41% and 28% of respondents would use knives and kitchen surfaces respectively in a manner that could allow cross contamination. The data in this survey are self-reported and, particularly for the hygiene questions, respondents may report an answer that they

  4. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  5. Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America

    International Nuclear Information System (INIS)

    Shortt, Conor P.; Morrison, William B.; Deely, Diane M.; Gopez, Angela G.; Zoga, Adam C.; Roberts, Catherine C.

    2009-01-01

    The aim of this study was to evaluate the range of techniques used by radiologists performing shoulder, hip, and knee arthrography using fluoroscopic guidance. Questionnaires on shoulder, hip, and knee arthrography were distributed to radiologists at a national radiology meeting. We enquired regarding years of experience, preferred approaches, needle gauge, gadolinium dilution, and volume injected. For each approach, the radiologist was asked their starting and end needle position based on a numbered and lettered grid superimposed on a radiograph. Sixty-eight questionnaires were returned. Sixty-eight radiologists performed shoulder and hip arthrography, and 65 performed knee arthrograms. Mean experience was 13.5 and 12.8 years, respectively. For magnetic resonance arthrography, a gadolinium dilution of 1/200 was used by 69-71%. For shoulder arthrography, an anterior approach was preferred by 65/68 (96%). The most common site of needle end position, for anterior and posterior approaches, was immediately lateral to the humeral cortex. A 22-gauge needle was used by 46/66 (70%). Mean injected volume was 12.7 ml (5-30). For hip arthrography, an anterior approach was preferred by 51/68 (75%). The most common site of needle end position, for anterior and lateral approaches, was along the lateral femoral head/neck junction. A 22-gauge needle was used by 53/68 (78%). Mean injected volume was 11.5 ml (5-20). For knee arthrography, a lateral approach was preferred by 41/64 (64%). The most common site of needle end position, for lateral and medial approaches, was mid-patellofemoral joint level. A 22-gauge needle was used by 36/65 (56%). Mean injected volume was 28.2 ml (5-60). Arthrographic approaches for the shoulder, hip, and knee vary among radiologists over a wide range of experience levels. (orig.)

  6. Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America

    Energy Technology Data Exchange (ETDEWEB)

    Shortt, Conor P. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States); Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Morrison, William B.; Deely, Diane M.; Gopez, Angela G.; Zoga, Adam C. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States); Roberts, Catherine C. [Mayo Clinic College of Medicine, Department of Radiology, Phoenix, AZ (United States)

    2009-04-15

    The aim of this study was to evaluate the range of techniques used by radiologists performing shoulder, hip, and knee arthrography using fluoroscopic guidance. Questionnaires on shoulder, hip, and knee arthrography were distributed to radiologists at a national radiology meeting. We enquired regarding years of experience, preferred approaches, needle gauge, gadolinium dilution, and volume injected. For each approach, the radiologist was asked their starting and end needle position based on a numbered and lettered grid superimposed on a radiograph. Sixty-eight questionnaires were returned. Sixty-eight radiologists performed shoulder and hip arthrography, and 65 performed knee arthrograms. Mean experience was 13.5 and 12.8 years, respectively. For magnetic resonance arthrography, a gadolinium dilution of 1/200 was used by 69-71%. For shoulder arthrography, an anterior approach was preferred by 65/68 (96%). The most common site of needle end position, for anterior and posterior approaches, was immediately lateral to the humeral cortex. A 22-gauge needle was used by 46/66 (70%). Mean injected volume was 12.7 ml (5-30). For hip arthrography, an anterior approach was preferred by 51/68 (75%). The most common site of needle end position, for anterior and lateral approaches, was along the lateral femoral head/neck junction. A 22-gauge needle was used by 53/68 (78%). Mean injected volume was 11.5 ml (5-20). For knee arthrography, a lateral approach was preferred by 41/64 (64%). The most common site of needle end position, for lateral and medial approaches, was mid-patellofemoral joint level. A 22-gauge needle was used by 36/65 (56%). Mean injected volume was 28.2 ml (5-60). Arthrographic approaches for the shoulder, hip, and knee vary among radiologists over a wide range of experience levels. (orig.)

  7. [Deep needling and shallow needling at three acupoints around ear for subjective tinnitus: a randomized controlled trial].

    Science.gov (United States)

    Yin, Tao; Ni, Jinxia; Zhu, Wenzeng

    2015-10-01

    To compare the effective differences between deep needling and shallow needling at three acupoints around ear for subjective tinnitus. Fifty patients with subjective tinnitus were randomized divided into a deep needling group and a shallow needling group, 25 cases in each group. Twenty-two patients in the deep needling group and 20 patients in the shallow needling group were brought into statistic in the end. In the two groups, the three acupoints around ear and distal acupoints were both selected. The acupoints of the affected side such as Yifeng (TE 17), Tinghui (GB 2), Ermen (TE 21), Zhigou (TE 6), Zhongzhu (TE 3) and Hegu (LI 4) were adopted. Yifeng (TE 17), Tinghui (GB 2) and Ermen (TE 21) were acupunctured 30-38 mm in the deep needling group and 15-20 mm in the shallow needling group. The other acupoints were conventionally acupunctured in the two groups. The needles were retained for 30 min,once a day and five times a week for all patients. The treatment was continuously for 4 weeks in the two groups. Tinnitus handicap inventory (THI) scores, tinnitus grades and visual analogue scale (VAS) for tinnitus sound levels were observed before and after treatment, and the effects of the two groups were compared. The total effective rate in the deep needling group was 59.1% (13/22), and it was better than 20.0% (4/20) in the shallow needling group (P deep needling, group, the THI score, tinnitus grade and the VAS score were improved than those before treatment (all P shallow needling group, the three above indices before and after treatment were not different in statistical significance (all P > 0.05). After treatment, all the three indices in the deep needling group were superior to those in the shallow needling group (all P shallow needling at the three acupoints.

  8. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  9. Uranium hexafluoride: A manual of good handling practices. Revision 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF{sub 6}) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF{sub 6} handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF{sub 6} handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF{sub 6} are also described. The procedures and systems described for safe handling of UF{sub 6} presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF{sub 6}. With proper consideration for its nuclear properties, UF{sub 6} may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical.

  10. Nurses infection prevention practices in handling injections: A case ...

    African Journals Online (AJOL)

    The adherence to basic infection prevention procedures/aseptic techniques in handling of injections by health workers is still a concern. The adherence to aseptic techniques in handling injections is significantly associated with the nurses to patients ratios. Therefore, it is imperative to improve nurse to patient ratio in public ...

  11. Safe handling of tritium

    International Nuclear Information System (INIS)

    1991-01-01

    The main objective of this publication is to provide practical guidance and recommendations on operational radiation protection aspects related to the safe handling of tritium in laboratories, industrial-scale nuclear facilities such as heavy-water reactors, tritium removal plants and fission fuel reprocessing plants, and facilities for manufacturing commercial tritium-containing devices and radiochemicals. The requirements of nuclear fusion reactors are not addressed specifically, since there is as yet no tritium handling experience with them. However, much of the material covered is expected to be relevant to them as well. Annex III briefly addresses problems in the comparatively small-scale use of tritium at universities, medical research centres and similar establishments. However, the main subject of this publication is the handling of larger quantities of tritium. Operational aspects include designing for tritium safety, safe handling practice, the selection of tritium-compatible materials and equipment, exposure assessment, monitoring, contamination control and the design and use of personal protective equipment. This publication does not address the technologies involved in tritium control and cleanup of effluents, tritium removal, or immobilization and disposal of tritium wastes, nor does it address the environmental behaviour of tritium. Refs, figs and tabs

  12. Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

    Science.gov (United States)

    Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich

    2005-02-01

    Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

  13. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  14. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  15. Needle autopsy

    Directory of Open Access Journals (Sweden)

    Philip Davis Marsden

    1997-04-01

    Full Text Available Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsia limitadamente fechada, para esclarecimento da histologia do órgão. Dessa maneira, o clínico pode resolver enigmas de doenças fatais.

  16. Assessment of bone biopsy needles for sample size, specimen quality and ease of use

    International Nuclear Information System (INIS)

    Roberts, C.C.; Liu, P.T.; Morrison, W.B.; Leslie, K.O.; Carrino, J.A.; Lozevski, J.L.

    2005-01-01

    To assess whether there are significant differences in ease of use and quality of samples among several bone biopsy needles currently available. Eight commonly used, commercially available bone biopsy needles of different gauges were evaluated. Each needle was used to obtain five consecutive samples from a lamb lumbar pedicle. Subjective assessment of ease of needle use, ease of sample removal from the needle and sample quality, before and after fixation, was graded on a 5-point scale. The number of attempts necessary to reach a 1 cm depth was recorded. Each biopsy specimen was measured in the gross state and after fixation. The RADI Bonopty 15 g and Kendall Monoject J-type 11 g needles were rated the easiest to use, while the Parallax Core-Assure 11 g and the Bard Ostycut 16 g were rated the most difficult. Parallax Core-Assure and Kendall Monoject needles had the highest quality specimen in the gross state; Cook Elson/Ackerman 14 g and Bard Ostycut 16 g needles yielded the lowest. The MD Tech without Trap-Lok 11 g needle had the highest quality core after fixation, while the Bard Ostycut 16 g had the lowest. There was a significant difference in pre-fixation sample length between needles (P<0.0001), despite acquiring all cores to a standard 1 cm depth. Core length and width decrease in size by an average of 28% and 42% after fixation. Bone biopsy needles vary significantly in performance. Detailed knowledge of the strengths and weaknesses of different needles is important to make an appropriate selection for each individual's practice. (orig.)

  17. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  18. Remote handling of JET in-torus components. A practical experience

    International Nuclear Information System (INIS)

    Mills, S.; Brade, R.; Edwards, P.

    2000-01-01

    This paper summarises the experiences gained from the extensive handling of JET components inside the torus. The problems involved with handling components not designed to be remotely handled and the methods used to overcome them are described and discussed with specific examples from recent JET remote operations. The method employed for remotely producing structural TIG welds is explained. The problems of dextrous manipulation in an inverted attitude are discussed and the methods of amelioration are described

  19. Remote handling for an ISIS target change

    International Nuclear Information System (INIS)

    Broome, T.A.; Holding, M.

    1989-01-01

    During 1987 two ISIS targets were changed. This document describes the main features of the remote handling aspects of the work. All the work has to be carried out using remote handling techniques. The radiation level measured on the surface of the reflector when the second target had been removed was about 800 mGy/h demonstrating that hands on operations on any part of the target reflector moderator assembly is not practical. The target changes were the first large scale operations in the Target Station Remote Handling Cell and a great deal was learned about both equipment and working practices. Some general principles emerged which are applicable to other active handling tasks on facilities like ISIS and these are discussed below. 8 figs

  20. Correlates of lending needles/syringes among HIV-seropositive injection drug users.

    Science.gov (United States)

    Metsch, Lisa R; Pereyra, Margaret; Purcell, David W; Latkin, Carl A; Malow, Robert; Gómez, Cynthia A; Latka, Mary H

    2007-11-01

    Among HIV-positive injection drug users (IDUs), we examined the correlates of lending needles/syringes with HIV-negative and unknown status injection partners. HIV-positive IDUs (N=738) from 4 cities in the United States who reported injection drug use with other IDUs in the past 3 months participated in an audio computer-assisted self-administered interview. Eighteen percent of study participants self-reported having lent their needles to HIV-negative or unknown status injection partners. Multivariate analyses showed that 6 variables were significantly associated with this high-risk injecting practice. Older IDUs, high school graduates, and those reporting more supportive peer norms for safer drug use were less likely to lend needles/syringes. Admission to a hospital for drug treatment in the past 6 months, having injected with >1 person in the past 3 months, and having more psychiatric symptoms were all associated with more risk. These findings underscore the need for a continued prevention focus on HIV-positive IDUs that recognizes the combination of drug use, mental health factors, and social factors that might affect this high-risk injecting practice, which could be associated with HIV and hepatitis C transmission.

  1. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E. [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT (United Kingdom); Mari, Jean Martial [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom and GePaSud, University of French Polynesia, Faa’a 98702, French Polynesia (France); West, Simeon J. [Department of Anaesthesia, University College Hospital, Main Theatres, Maple Bridge Link Corridor, Podium 3, 235 Euston Road, London NW1 2BU (United Kingdom); Ginsberg, Yuval; David, Anna L. [Institute for Women’s Health, University College London, 86-96 Chenies Mews, London WC1E 6HX (United Kingdom); Ourselin, Sebastien [Center for Medical Imaging Computing, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2015-10-15

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction with the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With

  2. Development of a virtual reality haptic Veress needle insertion simulator for surgical skills training.

    Science.gov (United States)

    Okrainec, A; Farcas, M; Henao, O; Choy, I; Green, J; Fotoohi, M; Leslie, R; Wight, D; Karam, P; Gonzalez, N; Apkarian, J

    2009-01-01

    The Veress needle is the most commonly used technique for creating the pneumoperitoneum at the start of a laparoscopic surgical procedure. Inserting the Veress needle correctly is crucial since errors can cause significant harm to patients. Unfortunately, this technique can be difficult to teach since surgeons rely heavily on tactile feedback while advancing the needle through the various layers of the abdominal wall. This critical step in laparoscopy, therefore, can be challenging for novice trainees to learn without adequate opportunities to practice in a safe environment with no risk of injury to patients. To address this issue, we have successfully developed a prototype of a virtual reality haptic needle insertion simulator using the tactile feedback of 22 surgeons to set realistic haptic parameters. A survey of these surgeons concluded that our device appeared and felt realistic, and could potentially be a useful tool for teaching the proper technique of Veress needle insertion.

  3. Fabrication of tungsten wire needles

    International Nuclear Information System (INIS)

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading

  4. Effects of the European Community directive on lifting and handling practice.

    Science.gov (United States)

    Docker, S M

    1993-07-01

    The new legislation on lifting and handling requires the application of ergonomic principles to manual handling operations. A written assessment is required for all unavoidable manual handling operations which involve the risk of injury to employees. Employers are now expected to provide equipment to enable staff to avoid lifting heavy loads.

  5. Effect and safety of deep needling and shallow needling for functional constipation: a multicenter, randomized controlled trial.

    Science.gov (United States)

    Wu, Jiani; Liu, Baoyan; Li, Ning; Sun, Jianhua; Wang, Lingling; Wang, Liping; Cai, Yuying; Ye, Yongming; Liu, Jun; Wang, Yang; Liu, Zhishun

    2014-12-01

    Aupuncture is widely used for functional constipation. Effect of acupuncture might be related to the depth of needling; however, the evidence is limited. This trial aimed to evaluate the effect and safety of deep needling and shallow needling for functional constipation, and to assess if the deep needling and shallow needling are superior to lactulose. We conducted a prospective, superiority-design, 5-center, 3-arm randomized controlled trial. A total of 475 patients with functional constipation were randomized to the deep needling group (237), shallow needling group (119), and lactulose-controlled group (119) in a ratio of 2:1:1. Sessions lasted 30 minutes each time and took place 5 times a week for 4 weeks in 2 acupuncture groups. Participants in the lactulose group took lactulose orally for 16 continuous weeks. The primary outcome was the change from baseline of mean weekly spontaneous bowel movements (SBMs) during week 1 to 4 (changes from the baselines of the weekly SBMs at week 8 and week 16 in follow-up period were also assessed simultaneously). Secondary outcomes were the weekly SBMs of each assessing week, the mean score change from the baseline of constipation-related symptoms over week 1 to 4, and the time to the first SBM. Emergency drug usage and adverse effects were monitored throughout the study.SBMs and constipation-related symptoms were all improved in the 3 groups compared with baseline at each time frame (Pdeep needling group, 2 (1.75) in the shallow needling group, and 2 (2) in the lactulose group (P>0.05, both compared with the lactulose group). The changes of mean weekly SBMs at week 8 and week 16 in the follow-up period were 2 (2), 2 (2.5) in the deep needling group, 2 (3), 1.5 (2.5) in the shallow needling group, and 1 (2), 1 (2) in the lactulose group (Pdeep or shallow needling group. Deep and shallow needling at Tianshu (ST25) can improve intestinal function remarkably and safely. Therapeutic effects of deep and shallow needling are not

  6. [Stiletto needle and needle-knife for influence of gravity index in treating knee osteoarthritis].

    Science.gov (United States)

    Gu, Li-Jun; Zhang, Bin; Li, Wen-Hua; Tang, Yan; Dong, Fu-Hui

    2017-12-25

    To explore stiletto needle and needle-knife for influence of double sufficient weight in treating knee osteoarthritis patients. One hundred and thirteen early and medium term knee osteoarthritis patients were randomly divided into three groups, including stiletto needle group(38 cases), needle-knife group (38 cases) and voltaren group (37 cases). In stiletto needle group, there were 13 males and 25 females with an average of(55.87±7.72) years old, treated by stiletto needle once a week, and 2 weeks were a course; there were 11 males and 27 females in needle-knife group with an average of(57.11±7.07) years old, treated by acupotome once a week, and 2 weeks were a course; there were 12 males and 25 females in voltaren group with an average age of(57.62±8.08) years old, treated by votalin emulsion smearing 3 to 5 cm on painful area of knee joint, three times a day for 2 weeks; 36 patients in normal group, including 11 males and 25 females with a mean age of (55.28±7.55) years old, treated with nothing. Gravitational four lattice used to measure bipedal back and forth load before and after treatment in further observe weight-bearing situation among three groups, d value, which was the distance from center of gravity to original point, was measured as a obvervational index, JOA score was used to evaluate clinical effect. Five patients were fall out, including 2 patients in stiletto needle group, 2 patients in needle-knife group and 1 patient in voltaren group. Other 108 patients were followed-up from 28 to 35 d with an average of 30 d, and without untoward effect. There was significant difference in d value between treatment group and control group at 1 month after treatment( P 0.05), and d value was decreased before treatment than that of after treatment. There was no significant difference in JOA score among treatment group after treatment at 1 month( P 0.05) after treatment at 1 month. Stiletto needle, needle-knife and voltaren for the treatment of knee

  7. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  8. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  9. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  10. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-01-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  11. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-02-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  12. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  13. Comparison of specimen adequacy in fine needle aspiration cytology performed with different gauge needles in palpable external swellings

    International Nuclear Information System (INIS)

    Sarfraz, T.; Bashir, S.; Tariq, H.; Malik, T.M.

    2013-01-01

    Background: Fine Needle Aspiration Cytology (FNAC) of external swellings may yield different specimen adequacy depending on different gauge needles used for aspiration. Objective: To compare the specimen adequacy aspirated by various gauge (21 and 22) needles in external palpable swellings of lymph nodes, thyroid gland, salivary glands, breast and soft tissue. Study Design: Comparative cross sectional study. Duration: Six months (1st Jan 2012 to 30th June 2012). Setting: Histopathology/Cytology department Combined Military Hospital Peshawar (Pakistan). Methodology: This was a prospective study of 200 cases in which FNAC was performed with either 21 or 22 gauge needles (100 cases with 21 gauge and 100 with 22 gauge needles). Equal number of aspirations were done with 21 and 22 gauge needles from the swellings of thyroid gland, lymph nodes, salivary glands, breast and soft tissue. Results were analyzed for specimen adequacy by using SPSS 17. Results: A total number of 200 cases were recruited in this study, out of which 100 were aspirated with 21 gauge needles and 100 with 22 gauge needles. Specimen adequacy in swellings of thyroid, lymph nodes and salivary glands was better with 22 gauge amounting 90%, 80% and 80% respectively, as compared to yield with 21 gauge needles which was 85%, 70% and 60% respectively. On the other hand in swellings of breast and soft tissue, the specimen adequacy was better with 21 gauge needles giving 98% and 90 % adequate yield respectively as compared to 22 gauge needles which was 70% and 40 % respectively. Conclusion: Needles of smaller gauge (22 gauge) give a better yield in swellings of thyroid, lymph nodes and salivary gland while in swellings of breast and soft tissue sample adequacy is better with larger gauge needle (21 gauge). (author)

  14. Understanding the physiology of postharvest needle abscission in balsam fir

    Directory of Open Access Journals (Sweden)

    Mason Thane Macdonald

    2015-11-01

    Full Text Available Balsam fir (Abies balsamea trees are commonly used as a specialty horticultural species for Christmas trees and associated greenery in eastern Canada and United States. Postharvest needle abscission has always been a problem, but is becoming an even bigger challenge in recent years presumably due to increased autumn temperatures and earlier harvesting practices. An increased understanding of postharvest abscission physiology in balsam fir may benefit the Christmas tree industry while simultaneously advancing our knowledge in senescence and abscission of conifers in general. Our paper describes the dynamics of needle abscission in balsam fir while identifying key factors that modify abscission patterns. Concepts such as genotypic abscission resistance, nutrition, environmental factors, and postharvest changes in water conductance and hormone evolution are discussed as they relate to our understanding of the balsam fir abscission physiology. Our paper ultimately proposes a pathway for needle abscission via ethylene and also suggests other potential alternative pathways based on our current understanding.

  15. Varying influences of motivation factors on employees' likelihood to perform safe food handling practices because of demographic differences.

    Science.gov (United States)

    Ellis, Jason D; Arendt, Susan W; Strohbehn, Catherine H; Meyer, Janell; Paez, Paola

    2010-11-01

    Food safety training has been the primary avenue for ensuring food workers are performing proper food handling practices and thus, serving safe food. Yet, knowledge of safe food handling practices does not necessarily result in actual performance of these practices. This research identified participating food service employees' level of agreement with four factors of motivation (internal motivations, communication, reward-punishment, and resources) and determined if respondents with different demographic characteristics reported different motivating factors. Data were collected from 311 food service employees who did not have any supervisory responsibilities. Intrinsic motivation agreement scores were consistently the highest of all four motivational factors evaluated and did not differ across any of the demographic characteristics considered. In contrast, motivation agreement scores for communication, reward-punishment, and resources did differ based on respondents' gender, age, place of employment, job status, food service experience, completion of food handler course, or possession of a food safety certification. In general, respondents agreed that these motivation factors influenced their likelihood to perform various safe food handling procedures. This research begins to illustrate how employees' demographic characteristics influence their responses to various motivators, helping to clarify the complex situation of ensuring safe food in retail establishments. Future research into why employee willingness to perform varies more for extrinsic motivation than for intrinsic motivation could assist food service managers in structuring employee development programs and the work environment, in a manner that aids in improving external motivation (communication, reward-punishment, and resources) and capitalizing on internal motivation.

  16. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  17. Smart surgical needle actuated by shape memory alloys for percutaneous procedures

    Science.gov (United States)

    Konh, Bardia

    . Design parameters influencing the steerability include the needle's diameter, wire diameter, pre-strain, and its offset from the needle. A simplified model was developed to decrease the computation time in iterative analyses of the optimization algorithm. In the fourth part of this work a design of an active needling system was proposed where actuation forces of SMAs as well as shape memory polymers (SMPs) were incorporated. SMP elements provide two major additional advantages to the design: (i) recovery of the SMP's plastic deformation by heating the element above its glass transition temperature, and (ii) achieving a higher needle deflection by having a softer stage of SMP at higher temperatures with less amount of actuation force. Finally, in the fifth and last part of this study, an Arbitrary-Lagrangian-Eulerian formulation in LS-DYNA software was used to model the solid-fluid interactions between the needle and tissue. A 150mm long needle was considered to bend within the tissue due to the interacting forces on its asymmetric bevel tip. Some additional assumptions were made to maintain a reasonable computational time, with no need of parallel processing, while having practical accuracies. Three experimental tests of needle steering in a soft phantom were performed to validate the simulation. Results: The finite element model of the active needle was first validated experimentally with developed prototypes. Several design parameters affecting the needle's deflection such as the needle's Young's modulus, the SMA's pre-strain and its offset from the neutral axis of the cannula were studied using the FE model. Then by the integration of the SMA characteristics with the automated optimization schemes an improved design of the active needle was obtained. Real-time experiments with different prototypes showed that the quickest response and the maximum deflection were achieved by the needle with two sections of actuation compared to a single section of actuation. Also the

  18. Evaluation of hygiene practices and microbiological quality of cooked meat products during slicing and handling at retail.

    Science.gov (United States)

    Pérez-Rodríguez, F; Castro, R; Posada-Izquierdo, G D; Valero, A; Carrasco, E; García-Gimeno, R M; Zurera, G

    2010-10-01

    Cooked meat ready-to-eat products are recognized to be contaminated during slicing which, in the last years, has been associated with several outbreaks. This work aimed to find out possible relation between the hygiene practice taking place at retail point during slicing of cooked meat products in small and medium-sized establishments (SMEs) and large-sized establishments (LEs) and the microbiological quality of sliced cooked meat products. For that, a checklist was drawn up and filled in based on scoring handling practice during slicing in different establishments in Cordoba (Southern Spain). In addition, sliced cooked meats were analyzed for different microbiological indicators and investigated for the presence of Listeria spp. and Listeria monocytogenes. Results indicated that SMEs showed a more deficient handling practices compared to LEs. In spite of these differences, microbiological counts indicated similar microbiological quality in cooked meat samples for both types of establishments. On the other hand, Listeria monocytogenes and Listeria inocua were isolated from 7.35% (5/68) and 8.82% (6/68) of analyzed samples, respectively. Positive samples for Listeria spp. were found in establishments which showed acceptable hygiene levels, though contamination could be associated to the lack of exclusiveness of slicers at retail points. Moreover, Listeria spp presence could not be statistically linked to any microbiological parameters; however, it was observed that seasonality influenced significantly (Phygiene practices, focused specially on SMEs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  19. Qualification of A type package for transport and final disposal of radium-226 needles

    International Nuclear Information System (INIS)

    Rodrigues, D.L.; Vicente, R.

    1988-01-01

    One of the objectives of the Fuel Cycle Department is to develop packages for radioactive wastes, including discarded industrial and radiotherapy sources. This paper describes the work undertaken to qualify a package for transport and final disposal of radium needles, and gives a detailed description of the tests carried out to verify shielding integrity and contaiment system before and after free drop test according to IAEA recomendations for type A, non-especial form packages. Shielding integrity was verified by gamma field scanning over the package surface, using a Geiger-Muller detector and a 60 Co gamma source. Containment system was verified by pressurizing the specimen with helium and by searching for leaks a He-leak detector, with sensitivity of 3 x 10 -10 atm x cm 3 /s, air equivalent. The package is described in detail along with the apparatus for the safe handling and packing of the radium needles. (author) [pt

  20. [Needling technique of Professor Li Yan-Fang].

    Science.gov (United States)

    Li, Li-Jun

    2014-01-01

    Experiences of needling techniques of Professor LI Ya- fang is introduced in this article. Gentle and superficial insertion is adopted by Professor LI in clinic. Emphases are put on the qi regulation function, needling sensation to the affected region and insertion with both hands, especially the function of the left hand as pressing hand. The gentle and superficial insertion should be done as the follows: hold the needle with the right hand, press gently along the running course of meridians with the left hand to promote qi circulation, hard pressing should be applied at acupoints to disperse the local qi and blood, insert the needle gently and quickly into the subcutaneous region with the right hand, and stop the insertion when patient has the needling sensation. While the fast needling is characterized with shallow insertion and swift manipulation: the left hand of the manipulator should press first along the running course of the meridian, and fix the local skin, hold the needle with the right hand and insert the needle quickly into the acupoint. Withdrawal of the needle should be done immediately after the reinforcing and reducing manipulations. Professor LI is accomplished in qi regulation. It is held by him that regulating qi circulation is essence of acupuncture, letting the patient get the needling sensation is the most important task of needling. Lifting, thrusting and rotation manipulations should be applied to do reinforcing or reducing. The tissue around the tip of the needle should not be too contracted or too relaxed, and the resistance should not be too strong or too weak. The feeling of the insertion hand of the practitioner should not be too smooth or too hesitant. Needle should be inserted into the skin quickly at the moment of hard pressing by the left hand. And then, slow rotation and gentle lifting and thrusting can be applied to promote the needling sensation like electric current pass through and to reach the affected region along the

  1. Sample handling in surface sensitive chemical and biological sensing: a practical review of basic fluidics and analyte transport.

    Science.gov (United States)

    Orgovan, Norbert; Patko, Daniel; Hos, Csaba; Kurunczi, Sándor; Szabó, Bálint; Ramsden, Jeremy J; Horvath, Robert

    2014-09-01

    This paper gives an overview of the advantages and associated caveats of the most common sample handling methods in surface-sensitive chemical and biological sensing. We summarize the basic theoretical and practical considerations one faces when designing and assembling the fluidic part of the sensor devices. The influence of analyte size, the use of closed and flow-through cuvettes, the importance of flow rate, tubing length and diameter, bubble traps, pressure-driven pumping, cuvette dead volumes, and sample injection systems are all discussed. Typical application areas of particular arrangements are also highlighted, such as the monitoring of cellular adhesion, biomolecule adsorption-desorption and ligand-receptor affinity binding. Our work is a practical review in the sense that for every sample handling arrangement considered we present our own experimental data and critically review our experience with the given arrangement. In the experimental part we focus on sample handling in optical waveguide lightmode spectroscopy (OWLS) measurements, but the present study is equally applicable for other biosensing technologies in which an analyte in solution is captured at a surface and its presence is monitored. Explicit attention is given to features that are expected to play an increasingly decisive role in determining the reliability of (bio)chemical sensing measurements, such as analyte transport to the sensor surface; the distorting influence of dead volumes in the fluidic system; and the appropriate sample handling of cell suspensions (e.g. their quasi-simultaneous deposition). At the appropriate places, biological aspects closely related to fluidics (e.g. cellular mechanotransduction, competitive adsorption, blood flow in veins) are also discussed, particularly with regard to their models used in biosensing. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  3. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types.

    Directory of Open Access Journals (Sweden)

    Lyubomyr Lytvynchuk

    Full Text Available A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements.

  4. Physical Properties Of Acupuncture Needles: Do Disposable Acupuncture Needles Break With Normal Use

    Science.gov (United States)

    2016-06-01

    Orofacial Pain Graduate...JOURNAL PHYSICAL PROPERTIES OF ACUPUNCTURE NEEDLES: DO DISPOSABLE ACUPUNCTURE NEEDLES BREAK WITH NORMAL USE? James Kyle Vick DDS, Orofacial Pain ...MS CAPT, DC, USN Orofacial Pain Department Head Naval Postgraduate Dental School vi    TABLE OF CONTENTS GUIDELINE I. TITLE

  5. A survey on knowledge and self-reported formula handling practices of parents and child care workers in Palermo, Italy

    Directory of Open Access Journals (Sweden)

    Mammina Caterina

    2009-12-01

    Full Text Available Abstract Background Powdered infant formula (PIF is not a sterile product, but this information appears to be poorly diffused among child caregivers. Parents and child care workers may behave in an unsafe manner when handling PIF. Methods This study involved parents and child care workers in the 24 municipal child care centres of Palermo. Knowledge and self-reported practices about PIF handling were investigated by a structured questionnaire. A Likert scale was used to measure the strength of the respondent's feelings. Association of knowledge and self-reported practices with demographic variables was also evaluated. Results 42.4% of parents and 71.0% of child care workers filled in the questionnaire. Significant differences were found between parents and child care workers for age and education. 73.2% of parents and 84.4% of child care workers were confident in sterility of PIF. Generally, adherence to safe procedures when reconstituting and handling PIF was more frequently reported by child care workers who, according to the existing legislation, are regularly subjected to a periodic training on food safety principles and practices. Age and education significantly influenced the answers to the questionnaire of both parents and child care workers. Conclusion The results of the study reveal that parents and child care workers are generally unaware that powdered formulas may contain viable microorganisms. However, child care workers consistently chose safer options than parents when answering the questions about adherence to hygienic practices. At present it seems unfeasible to produce sterile PIF, but the risk of growth of hazardous organisms in formula at the time of administration should be minimized by promoting safer behaviours among caregivers to infants in both institutional settings and home.

  6. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  7. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  8. Education and training for advanced practice: Principles of course design and assessment applied to a 'stereotactic needle core biopsy of the breast' module

    International Nuclear Information System (INIS)

    Dixon, Anne-Marie

    2006-01-01

    In order to realise the promise of the NHS Plan, radiographers are extending their practice to encompass tasks previously undertaken by radiologists and advancing their practice by taking responsibility for clinical decision-making and autonomous membership of multidisciplinary healthcare teams. In partnership with clinical service providers Higher Education Institutes are devising programmes of study to support such professional development. This article reviews the design of a 20 credit post-graduate (M level) module in stereotactic needle core biopsy of the breast. Particular consideration is given to underpinning educational principles of course design and assessment and how these are applied in order that teaching, learning and assessment have academic rigour and clinical competence of successful students is assured

  9. Ergonomics: safe patient handling and mobility.

    Science.gov (United States)

    Hallmark, Beth; Mechan, Patricia; Shores, Lynne

    2015-03-01

    This article reviews and investigates the issues surrounding ergonomics, with a specific focus on safe patient handling and mobility. The health care worker of today faces many challenges, one of which is related to the safety of patients. Safe patient handling and mobility is on the forefront of the movement to improve patient safety. This article reviews the risks associated with patient handling and mobility, and informs the reader of current evidence-based practice relevant to this area of care. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Intra-operative navigation of a 3-dimensional needle localization system for precision of irreversible electroporation needles in locally advanced pancreatic cancer.

    Science.gov (United States)

    Bond, L; Schulz, B; VanMeter, T; Martin, R C G

    2017-02-01

    Irreversible electroporation (IRE) uses multiple needles and a series of electrical pulses to create pores in cell membranes and cause cell apoptosis. One of the demands of IRE is the precise needle spacing required. Two-dimensional intraoperative ultrasound (2-D iUS) is currently used to measure inter-needle distances but requires significant expertise. This study evaluates the potential of three-dimensional (3-D) image guidance for placing IRE needles and calculating needle spacing. A prospective clinical evaluation of a 3-D needle localization system (Explorer™) was evaluated in consecutive patients from April 2012 through June 2013 for unresectable pancreatic adenocarcinoma. 3-D reconstructions of patients' anatomy were generated from preoperative CT images, which were aligned to the intraoperative space. Thirty consecutive patients with locally advanced pancreatic cancer were treated with IRE. The needle localization system setup added an average of 6.5 min to each procedure. The 3-D needle localization system increased surgeon confidence and ultimately reduced needle placement time. IRE treatment efficacy is highly dependent on accurate needle spacing. The needle localization system evaluated in this study aims to mitigate these issues by providing the surgeon with additional visualization and data in 3-D. The Explorer™ system provides valuable guidance information and inter-needle distance calculations. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  11. Effect of Blinding With a New Pragmatic Placebo Needle

    Science.gov (United States)

    Liu, Baoyan; Xu, Huanfang; Ma, Rui; Mo, Qian; Yan, Shiyan; Liu, Zhishun

    2014-01-01

    Abstract Placebo control is a useful method for determining the efficacy of a therapy. In acupuncture researches, the preferred method for placebo control is acupuncture using a placebo needle that has a blunt tip and achieves no skin penetration. We performed a crossover study to validate the blinding effect of a new type of placebo needle. Sixty volunteers were randomized to receive acupuncture using 2 types of needles with different sequences: sequence AB, involving first the pragmatic placebo needle and then the real needle, and sequence BA, in a reverse order. Placebo acupuncture was performed by administering the placebo needle through an adhesive pad without skin penetration on the acupoints LI4, RN12, BL25, and BL36. Real acupuncture was performed by needling through the pad and penetrating the skin to 15 mm using a real needle on the same acupoints. The acupuncture was administered every other day with 3 sessions for 1 type of needle. The primary outcome was the perception of needle penetration. Besides degree of acupuncture pain, type, and degree of needle sensation, needle acceptability and factors influencing the subject blinding effect were assessed. Needle penetration was felt by 100%, 90% (54/60), 88.3% (53/60), and 95% (57/60) of volunteers receiving placebo acupuncture and 98.3% (59/60), 96.7% (58/60), 95% (57/60), and 95% (57/60) of volunteers receiving real acupuncture on LI4, RN12, BL25, and BL36, respectively. Differences of the volunteers’ perception of needle penetration between the placebo needle and real needle were not significant for the 4 acupoints (all P > 0.05). Volunteers experienced fewer distension sensations (P = 0.01), a lower degree of needle sensation (P = 0.007), and less pain (P = 0.006) during placebo acupuncture than during real acupuncture. The placebo needle was more easily accepted than the real needle (OR = 1.63, 95% CI, 1.01–2.64). The influences of age, sex, educational level, acupuncture

  12. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  13. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  14. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  15. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Camille Chesnel

    Full Text Available Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia.To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers.Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred.Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%: 4 (1% in tendons or muscles, 3 (0.7% in nerves and 1 (0.2% in a vessel.This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  16. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Science.gov (United States)

    Chesnel, Camille; Genêt, François; Almangour, Waleed; Denormandie, Philippe; Parratte, Bernard; Schnitzler, Alexis

    2015-01-01

    Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning) is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia. To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers. Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons) carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred. Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%): 4 (1%) in tendons or muscles, 3 (0.7%) in nerves and 1 (0.2%) in a vessel. This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  17. Numerical Modelling of Mutual Effect among Nearby Needles in a Multi-Needle Configuration of an Atmospheric Air Dielectric Barrier Discharge

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2012-05-01

    Full Text Available A numerical study has been conducted to understand the mutual effect among nearby needles in a multi-needle electrode dielectric barrier discharge. In the present paper, a fluid-hydrodynamic model is adopted. In this model, the mutual effect among nearby needles in a multi-needle configuration of an atmospheric air dielectric barrier discharge are investigated using a fluid-hydrodynamic model including the continuity equations for electrons and positive and negative ions coupled with Poisson’s equation. The electric fields at the streamer head of the middle needle (MN and the side needles (SNs in a three-needle model decreased under the influence of the mutual effects of nearby needles compared with that in the single-needle model. In addition, from the same comparison, the average propagation velocities of the streamers from MN and SNs, the electron average energy profile of MN and SNs (including those in the streamer channel, at the streamer head, and in the unbridged gap, and the electron densities at the streamer head of the MN and SNs also decreased. The results obtained in the current paper agreed well with the experimental and simulation results in the literature.

  18. 21 CFR 58.107 - Test and control article handling.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Test and control article handling. 58.107 Section... GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Test and Control Articles § 58.107 Test and control article handling. Procedures shall be established for a system for the handling of the test and...

  19. Getting to grips with remote handling and robotics

    Energy Technology Data Exchange (ETDEWEB)

    Mosey, D [Ontario Hydro, Toronto (Canada)

    1984-12-01

    A report on the Canadian Nuclear Society Conference on robotics and remote handling in the nuclear industry, September 1984. Remote handling in reactor operations, particularly in the Candu reactors is discussed, and the costs and benefits of use of remote handling equipment are considered. Steam generator inspection and repair is an area in which practical application of robotic technology has made a major advance.

  20. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  1. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  2. Safe injection practice among health care workers, Gharbiya, Egypt.

    Science.gov (United States)

    Ismail, Nanees A; Aboul Ftouh, Aisha M; El Shoubary, Waleed H

    2005-01-01

    A cross-sectional study was conducted in 25 health care facilities in Gharbiya governorate to assess safe injection practices among health care workers (HCWs). Two questionnaires, one to collect information about administrative issues related to safe injection and the other to collect data about giving injections, exposure to needle stick injuries, hepatitis B vaccination status and safe injection training. Practices of injections were observed using a standardized checklist. The study revealed that there was lack of both national and local infection control policies and lack of most of the supplies needed for safe injection practices. Many safe practices were infrequent as proper needle manipulation before disposal (41%), safe needle disposal (47.5%), reuse of used syringe & needle (13.2%) and safe syringe disposal (0%). Exposure to needle stick injuries were common among the interviewed HCWs (66.2%) and hand washing was the common post exposure prophylaxis measure (63.4%). Only 11.3% of HCWs had full course hepatitis B vaccination. Infection control -including safe injections- training programs should be afforded to all HCWs.

  3. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  4. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  5. Processing and Characterization of Needled Carbon Composites

    Science.gov (United States)

    2015-12-01

    needle is used to insert high strength yarns (i.e., threads) through the dry fabric or prepreg laminate , leaving a loose thread loop underneath [9-11...capability which uses commercially-available felting needles to insert z-fibers into composite laminates at different angles (±45/90°) relative to the... laminate plane. Previous work with needled glass/epoxy composites has shown a 270% improvement in Mode I interlaminar fracture toughness when needled

  6. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  7. Moving and handling education in the community: technological innovations to improve practice.

    Science.gov (United States)

    Wanless, Stephen; Page, Andrea

    2009-12-01

    Efforts to reduce injuries associated with patient handling are often based on tradition and personal experience rather than sound educational theory. The purpose of this article is to summarize current evidence for educational interventions designed to reduce primary care staff injuries: a significant problem for decades. Evidence suggests that the current 'classroom' teaching of moving and handling is ineffective. There is a growing body of evidence to support newer interventions that are effective or show promise in reducing musculoskeletal injuries in health professionals (Freitag et al, 2007). The authors discuss potential solutions through moving and handling-related motion capture simulation and the use of e-learning to promote an understanding of the principles associated with patient handling tasks.

  8. Needle thoracostomy in the treatment of a tension pneumothorax in trauma patients: what size needle?

    Science.gov (United States)

    Zengerink, Imme; Brink, Peter R; Laupland, Kevin B; Raber, Earl L; Zygun, Dave; Kortbeek, John B

    2008-01-01

    A tension pneumothorax requires immediate decompression using a needle thoracostomy. According to advanced trauma life support guidelines this procedure is performed in the second intercostal space (ICS) in the midclavicular line (MCL), using a 4.5-cm (2-inch) catheter (5-cm needle). Previous studies have shown a failure rate of up to 40% using this technique. Case reports have suggested that this high failure rate could be because of insufficient length of the needle. To analyze the average chest wall thickness (CWT) at the second ICS in the MCL in a trauma population and to evaluate the length of the needle used in needle thoracostomy for emergency decompression of tension pneumothoraces. Retrospective review of major trauma admissions (Injury Severity Score >12) at the Foothills Medical Centre in Calgary, Canada, who underwent a computed tomography chest scan admitted in the period from October 2001 until March 2004. Subgroup analysis on men and women, /=40 years of age was defined a priori. CWT was measured to the nearest 0.01 cm at the second ICS in the MCL. The mean CWT in the 604 male patients and 170 female patients studied averaged 3.50 cm at the left second ICS MCL and 3.51 cm on the right. The mean CWT was significantly higher for women than men (p 4.5 cm and 24.1% to 35.4% of the women studied. A catheter length of 4.5 cm may not penetrate the chest wall of a substantial amount (9.9%-35.4%) of the population, depending on age and gender. This study demonstrates the need for a variable needle length for relief of a tension pneumothorax in certain population groups to improve effectiveness of needle thoracostomy.

  9. Code of practice for the control and safe handling of radioactive sources used for therapeutic purposes (1988)

    International Nuclear Information System (INIS)

    1988-01-01

    This Code is intended as a guide to safe practices in the use of sealed and unsealed radioactive sources and in the management of patients being treated with them. It covers the procedures for the handling, preparation and use of radioactive sources, precautions to be taken for patients undergoing treatment, storage and transport of radioactive sources within a hospital or clinic, and routine testing of sealed sources [fr

  10. Religious Serpent Handling and Community Relations.

    Science.gov (United States)

    Williamson, W Paul; Hood, Ralph W

    2015-01-01

    Christian serpent handling sects of Appalachia comprise a community that has long been mischaracterized and marginalized by the larger communities surrounding them. To explore this dynamic, this article traces the emergence of serpent handling in Appalachia and the emergence of anti-serpent-handling state laws, which eventually failed to curb the practice, as local communities gave serpent handling groups support. We present two studies to consider for improving community relations with serpent handling sects. In study 1, we present data relating the incidence of reported serpent-bite deaths with the rise of anti-serpent-handling laws and their eventual abatement, based on increasing acceptance of serpent handlers by the larger community. Study 2 presents interview data on serpent bites and death that provide explanations for these events from the cultural and religious perspective. We conclude that first-hand knowledge about serpent handlers, and other marginalized groups, helps to lessen suspicion and allows them to be seen as not much different, which are tendencies that are important for promoting inter-community harmony.

  11. 21 CFR 868.5150 - Anesthesia conduction needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient to...

  12. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  13. [Professor WU Zhongchao's experience of penetration needling].

    Science.gov (United States)

    Zhang, Ning; Wang, Bing; Zhou, Yu

    2016-08-12

    Professor WU Zhongchao has unique application of penetration needling in clinical treatment. Professor WU applies penetration needling along meridians, and the methods of penetration needling include self-meridian penetration, exterior-interior meridian penetration, identical-name meridian penetration, different meridian penetration. The meridian differentiation is performed according to different TCM syndromes, locations and natures of diseases and acupoint nature, so as to make a comprehensive assessment. The qi movement during acupuncture is focused. In addition, attention is paid on anatomy and long-needle penetration; the sequence and direction of acupuncture is essential, and the reinforcing and reducing methods have great originality, presented with holding, waiting, pressing and vibrating. Based on classical acupoint, the acupoint of penetration needling is flexible, forming unique combination of acupoints.

  14. Effect of bidirectional rotation of an acupuncture needle at LI10 on acupuncture needle sensation and experimentally-induced contact heat pain in healthy human volunteers.

    Science.gov (United States)

    Benham, Alex; Johnson, Mark I

    2014-06-01

    There is insufficient evidence of a relationship between acupuncture needle sensations (de qi) and hypoalgesia. The aim of this study was to investigate the effects of bidirectional needle rotation at LI10 on acupuncture needle sensations and heat pain thresholds. Twenty-two healthy participants received one acupuncture needle at LI10 with bidirectional rotation of the needle in one experimental session and one acupuncture needle at LI10 with mock rotation in a separate session, in a randomised order. Measurements of heat pain thresholds were taken before needle insertion, during needle retention and 15 min after needle removal. At each measurement time point, participants rated needle sensations using the Massachusetts Acupuncture Sensation Scale (MASS) and a visual analogue scale (VAS) of overall intensity of needle sensation. Bidirectional needle rotation produced significantly higher scores for VAS, MASStotal, MASSpain and MASSsensation compared with mock rotation (all psensation and change in pain threshold after needling was only found when data from mock and rotation interventions were combined. Needle rotation increases the magnitude of hypoalgesia. There is tentative evidence that needle sensation may be associated with the amount of change in pain threshold. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  16. Observations of needle-tissue interactions

    NARCIS (Netherlands)

    Misra, Sarthak; Reed, Kyle B.; Ramesh, K.T.; Okamura, Allison M.

    2009-01-01

    Needles with asymmetric bevel tips naturally bend when they are inserted into soft tissue. In this study, we present an analytical model for the loads developed at the bevel tip during needle-tissue interaction. The model calculates the loads based on the geometry of the bevel edge and gel material

  17. Radio-frequency ablation in patients with malignant hepatic tumor and experimental model: comparison of expandable needle and water-cooled needle

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Yong Ju; Jeong, Yong Yeon; Kim, Jeong; Yim, Nam yeol; Kang, Heoung Keun [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of); Kim, Eun Ha; Yoon, Kwon Ha [School of Medicine, Wonkwang Univ., Iksan (Korea, Republic of); Ko, Seog Wan [School of Medicine, Chonbuk National Univ., Jeonju (Korea, Republic of)

    2004-12-01

    The purpose of this study was to compare the shape and volume of the radio-frequency induced lesions produced by two commercially available radio-frequency ablation (RFA) systems, the expandable and cooled-tip needles, in clinical patients and an experimental model. A twelve-array anchor expandable needle electrode and a single cooled-tip needle electrode were used to treat hepatic tumors with a single session in 23 patients (20 hepatocellular carcinomas and 3 hepatic metastases) and fourteen patients (10 hepatocellular carcinomas and 4 hepatic metastases), respectively. Twenty RFA induced lesions were created with each system in 10 explanted bovine livers. The shape of the RFA induced lesions were divided into oval lesions along or perpendicular to the axis of the electrode and spherical lesions, and we then calculated the volumes of the RFA induced lesions. Fourteen (61%) lesions of the 23 patients treated with the expandable system were oval perpendicular to the axis of the electrode and nine (39%) of the lesions were spherical. All the lesions (100%) of the 14 patients treated with the cooled-tip needle were ovaI along the axis of the electrode. In the ex vivo bovine livers, the shape of the all RFA induced lesions was oval perpendicular to the axis of the electrode for the expandable needle, and oval along the axis of the electrode for the cooled-tip needle. The mean diameter and volume of the RFA induced lesions in the patients were 3.35{+-}0.56 cm and 19.9{+-}6.53 cm{sup 3}, respectively, for the expandable needle and 3.58{+-}0.78 cm and 23.19{+-}5.27 cm{sup 3}, respectively, for the cooled-tip needle. In the ex vivo model, the mean diameter and volume of RFA induced lesions were 3.41{+-}0.59 cm and 26.59{+-}8.02 cm{sup 3}, respectively, for the expandable needle, and 4.04{+-}0.65 cm and 33.82{+-}6.16 cm{sup 3}, respectively, for the cooled-tip needle (p <0.05). These results indicate that the shape of RFA induced lesions with the expandable needle were oval

  18. Cooper-Harper Experience Report for Spacecraft Handling Qualities Applications

    Science.gov (United States)

    Bailey, Randall E.; Jackson, E. Bruce; Bilimoria, Karl D.; Mueller, Eric R.; Frost, Chad R.; Alderete, Thomas S.

    2009-01-01

    A synopsis of experience from the fixed-wing and rotary-wing aircraft communities in handling qualities development and the use of the Cooper-Harper pilot rating scale is presented as background for spacecraft handling qualities research, development, test, and evaluation (RDT&E). In addition, handling qualities experiences and lessons-learned from previous United States (US) spacecraft developments are reviewed. This report is intended to provide a central location for references, best practices, and lessons-learned to guide current and future spacecraft handling qualities RDT&E.

  19. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  20. [An Introduction to A Newly-developed "Acupuncture Needle Manipulation Training-evaluation System" Based on Optical Motion Capture Technique].

    Science.gov (United States)

    Zhang, Ao; Yan, Xing-Ke; Liu, An-Guo

    2016-12-25

    In the present paper, the authors introduce a newly-developed "Acupuncture Needle Manipulation Training-evaluation System" based on optical motion capture technique. It is composed of two parts, sensor and software, and overcomes some shortages of mechanical motion capture technique. This device is able to analyze the data of operations of the pressing-hand and needle-insertion hand during acupuncture performance and its software contains personal computer (PC) version, Android version, and Internetwork Operating System (IOS) Apple version. It is competent in recording and analyzing information of any ope-rator's needling manipulations, and is quite helpful for teachers in teaching, training and examining students in clinical practice.

  1. Attitudes of western Canadian cow-calf producers towards the Code of Practice for the Care and Handling of Beef Cattle.

    Science.gov (United States)

    Moggy, Melissa; Pajor, Edmond; Thurston, Wilfreda; Parker, Sarah; Greter, Angela; Schwartzkopf-Genswein, Karen; Campbell, John; Windeyer, M Claire

    2017-11-01

    This study describes western Canadian cow-calf producers' attitudes towards the Code of Practice for the Care and Handling of Beef Cattle (COPB). Most respondents had not read the COPB. Of those familiar with the COPB, most agreed with it, but it did not have a major influence on their decisions.

  2. Pine needle abortion biomarker detected in bovine fetal fluids

    Science.gov (United States)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  3. Sample handling of clinical specimens for ultratrace element analysis

    International Nuclear Information System (INIS)

    Cornelis, R.

    1987-01-01

    Some simple logistics to an improved sample handling of clinical specimens are presented. This comprises clean room conditions, clean laboratory ware, ultra-pure reagents and good analytical practice. Sample handling procedures for blood, urine, soft tissues and pharmaceuticals are briefly discussed. (author) 26 refs

  4. STUDY & ANALYSIS OF MICRO NEEDLE MATERIAL BY ANSYS

    OpenAIRE

    Santosh Kumar Singh*, Prabhat Sinha, N.N. Singh, Nagendra Kumar

    2017-01-01

    In this research the concept of design and analysis, silicon and stainless steel based on hollow micro-needles for transdermal drug delivery(TDD) have been evaluated by Using ANSYS & computational fluid dynamic (CFD), structural. Micro fluidic analysis has performed to ensure the micro-needles design suitability for Drug delivery. The effect of axial and transverse load on single and micro-needle array has investigated with the mechanical properties of micro-needle. The analysis predicte...

  5. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  6. A gravimetric simplified method for nucleated marrow cell counting using an injection needle.

    Science.gov (United States)

    Saitoh, Toshiki; Fang, Liu; Matsumoto, Kiyoshi

    2005-08-01

    A simplified gravimetric marrow cell counting method for rats is proposed for a regular screening method. After fresh bone marrow was aspirated by an injection needle, the marrow cells were suspended in carbonate buffered saline. The nucleated marrow cell count (NMC) was measured by an automated multi-blood cell analyzer. When this gravimetric method was applied to rats, the NMC of the left and right femurs had essentially identical values due to careful handling. The NMC at 4 to 10 weeks of age in male and female Crj:CD(SD)IGS rats was 2.72 to 1.96 and 2.75 to 1.98 (x10(6) counts/mg), respectively. More useful information for evaluation could be obtained by using this gravimetric method in addition to myelogram examination. However, some difficulties with this method include low NMC due to blood contamination and variation of NMC due to handling. Therefore, the utility of this gravimetric method for screening will be clarified by the accumulation of the data on myelotoxicity studies with this method.

  7. Consumer knowledge, storage, and handling practices regarding Listeria in frankfurters and deli meats: results of a Web-based survey.

    Science.gov (United States)

    Cates, Sheryl C; Morales, Roberta A; Karns, Shawn A; Jaykus, Lee-Ann; Kosa, Katherine M; Teneyck, Toby; Moore, Christina M; Cowen, Peter

    2006-07-01

    Proper storage and handling of refrigerated ready-to-eat foods can help reduce the risk of listeriosis. A national Web-based survey was conducted to measure consumer awareness and knowledge of Listeria and to estimate the prevalence of the U.S. Department of Agriculture-recommended consumer storage and handling practices for frankfurters and deli meats. The demographic characteristics of consumers who are unaware of Listeria and who do not follow the recommended storage guidelines were also assessed. In addition, predictive models were developed to determine which consumers engage in risky storage practices. Less than half of the consumers surveyed were aware of Listeria, and most of those aware were unable to identify associated food vehicles. Awareness was lower among adults 60 years of age and older, an at-risk population for listeriosis, and individuals with relatively less education and lower incomes. Most households safely stored and prepared frankfurters. Most households stored unopened packages of vacuum-packed deli meats in the refrigerator within the U.S. Department of Agriculture-recommended storage guidelines (deli meats and freshly sliced deli meats for longer than the recommended time (< or =5 days). Men, more-educated individuals, and individuals living in metropolitan areas were more likely to engage in risky storage practices. This study identified the need to develop targeted educational initiatives on listeriosis prevention.

  8. Human factors issues in fuel handling

    International Nuclear Information System (INIS)

    Beattie, J.D.; Iwasa-Madge, K.M.; Tucker, D.A.

    1994-01-01

    The staff of the Atomic Energy Control Board wish to further their understanding of human factors issues of potential concern associated with fuel handling in CANDU nuclear power stations. This study contributes to that objective by analysing the role of human performance in the overall fuel handling process at Ontario Hydro's Darlington Nuclear Generating Station, and reporting findings in several areas. A number of issues are identified in the areas of design, operating and maintenance practices, and the organizational and management environment

  9. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  10. Migration of innumerable chronically retained acupuncture needles

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2017-09-01

    Full Text Available We present a case of a 50-year-old female with a 2-day history of back and abdominal pain who was discovered to have innumerable chronically retained acupuncture needles, which had migrated throughout her abdomen and pelvis. Although many of these needles were in precarious positions, including the epidural space, renal parenchyma, small bowel, and vasculature, there was no evidence for acute injury. We also briefly discuss evidence for the magnetic resonance imaging compatibility of acupuncture needles. Although a rare complication, given the high frequency of acupuncture therapy in the United States, physicians must be aware of the potential for retained and migrated needles.

  11. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  12. Five-Year Impacts of Swiss Needle Cast on Douglas-fir in Interior Forests of Oregon, USA

    Directory of Open Access Journals (Sweden)

    FILIP, Gregory

    2007-01-01

    Full Text Available In 2001 and 2006, we examined 590 Douglas-firs in 59 stands age 10-23 years in the northern Cascade Mountain foothills in Oregon, USA. Mean 5-year-dbh growth was 6.1 cm and total-height growth was 3.6 m. Mean needle-retention index increased by 3.4 over 5 years, and mid-crown retention increased by 1.2 years. Mean percentages of stomata occluded by pseudothecia of Phaeocryptopus gaeumannii were 13.6% for 2000-(2-year-old needles and 1.7% for 2001-(1-year-old needles sampled in 2002, and 13.3% for 2004 (2-year-old needles sampled in 2006. Mean crown-length to sapwood-area ratio was 5.2 cm/cm2 in 2006. There were poor correlations (R2 <0.3 among all variables except for a moderate correlation between stand elevation and either 2000-stomata occluded (R2 = 0.43 or 2004-stomata occluded (R2 = 0.50, where there were fewer pseudothecia at the higher elevations. Either 5 years is not enough time to evaluate the affects of Swiss needle cast on Douglas-fir growth in the Oregon Cascades or there was no significant effect of Swiss needle cast during the latest outbreak on Douglas-fir growth. Based on our results and their interpretation, forest managers may need not alter their current practices in the northern Oregon Cascades, and managing a mix of Douglas-fir and western hemlock at lower elevations and noble fir at higher elevations will help offset any future stand-growth declines due to Swiss needle cast.

  13. Practices of Handling

    DEFF Research Database (Denmark)

    Ræbild, Ulla

    Abstract While few will dispute the idea that fashion designers relate to the notion of the body in their work practice, the actual embodied engagement of the designer, and the role that the personal bodies of the designers play in processes of fashion design, is an underexposed although nascent...... introduces four ways whereby fashion designers apply their own bodies as tools for design; a) re-activating past garment-design experiences, b) testing present garment-design experiences c) probing for new garment-design experiences and d) design of future garment experiences by body proxy. The paper...... is based on the Ph.D. thesis Addressing the Body – methodological practises in professional fashion design finalised October 2014 (Ræbild, in press)...

  14. Investigation of environmental pollution with pine needles by NAA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Yong; Yoon, Yoon Yeol; Yang, Myung Kwon; Shim, Sang Kwon; Seo, Bum Kyoung [Korea Inst. of Geosience and Mineral Resources, Environmental Geology Division, Daejeon (Korea); Chung, Yong Sam [Korea Atomic Energy Research Inst., HANARO Center, Daejeon (Japan)

    2002-04-01

    NAA was studied to precision analysis of metallic elements in pine needle. The pine needle was investigated whether it can be feasible or not as a bio-monitor. Only one year old needle was taken from three different regions of urban, suburban and rural area in four seasons. The needle sample was divided with two aliquots, and then one was cleaned and the other was not. Loss and contamination of analytes were cautiously minimized when the needle was sample and transferred from mountain to laboratory and prepared for NAA. Some elements such as As, Br, Ce, W, Zn have shown different characteristics with regions and seasons as well as surface cleaning. It is found that about twenty elements in pine needle could be simply analyzed by NAA and the pine needle could be suitable as a bio-monitor for the monitoring of environmental pollution in Korea. (author)

  15. Understanding the Physiology of Postharvest Needle Abscission in Balsam Fir

    OpenAIRE

    Lada, Rajasekaran R.; MacDonald, Mason T.

    2015-01-01

    Balsam fir (Abies balsamea) trees are commonly used as a specialty horticultural species for Christmas trees and associated greenery in eastern Canada and United States. Postharvest needle abscission has always been a problem, but is becoming an even bigger challenge in recent years presumably due to increased autumn temperatures and earlier harvesting practices. An increased understanding of postharvest abscission physiology in balsam fir may benefit the Christmas tree industry while simulta...

  16. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Belgian and Spanish consumption data and consumer handling practices for fresh fruits and vegetables useful for further microbiological and chemical exposure assessment.

    Science.gov (United States)

    Jacxsens, L; Ibañez, I Castro; Gómez-López, V M; Fernandes, J Araujo; Allende, A; Uyttendaele, M; Huybrechts, I

    2015-04-01

    A consumer survey was organized in Spain and Belgium to obtain consumption data and to gain insight into consumer handling practices for fresh vegetables consumed raw or minimally processed (i.e., heads of leafy greens, bell peppers, tomatoes, fresh herbs, and precut and packed leafy greens) and fruits to be consumed without peeling (i.e., apples, grapes, strawberries, raspberries, other berries, fresh juices, and precut mixed fruit). This information can be used for microbiological and/or chemical food safety research. After extensive cleanup of rough databases for missing and extreme values and age correction, information from 583 respondents from Spain and 1,605 respondents from Belgium (18 to 65 years of age) was retained. Daily intake (grams per day) was calculated taking into account frequency and seasonality of consumption, and distributions were obtained that can be used in quantitative risk assessment for chemical hazards with chronic effects on human health. Data also were recalculated to obtain discrete distributions of consumption per portion and the corresponding frequency of consumption, which can be used in acute microbiological risk assessment or outbreak investigations. The ranked median daily consumption of fruits and vegetables was similar in Spain and Belgium: apple > strawberry > grapes > strawberries and raspberries; and tomatoes > leafy greens > bell peppers > fresh herbs. However, vegetable consumption was higher (in terms of both portion and frequency of consumption) in Spain than in Belgium, whereas the opposite was found for fruit consumption. Regarding consumer handling practices related to storage time and method, Belgian consumers less frequently stored their fresh produce in a refrigerator and did so for shorter times compared with Spanish consumers. Washing practices for lettuce heads and packed leafy greens also were different. The survey revealed differences between these two countries in consumption and consumer handling practices

  18. Exploring needle anxiety among students attending a Nigerian ...

    African Journals Online (AJOL)

    Needle anxiety, a form of specific phobia refers to an intense fear of needles used for various medical procedures. It may result in the avoidance of such needle-involving procedures like intramuscular injections or vaccinations. About 4-8% of children and adolescents are said to generally suffer some form of anxiety.

  19. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  20. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  1. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  2. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  3. The number of injected same-day preschool vaccines relates to preadolescent needle fear and HPV uptake.

    Science.gov (United States)

    Baxter, Amy L; Cohen, Lindsey L; Burton, Mark; Mohammed, Anaam; Lawson, M Louise

    2017-07-24

    Fear of needles develops at approximately five years of age, and decreases compliance with healthcare. We sought to examine the relationship of preschool vaccine history, parent and preadolescent needle fear, and subsequent compliance with optional vaccines. As part of a private practice randomized controlled trial, parents and 10-12year olds rated needle anxiety on a 100mm visual analog scale. This follow-up cohort study compared their needle anxiety to previous vaccination records, including number of vaccinations between ages four and six years (total and same-day maximum), and subsequent initiation of the HPV vaccine through age 13. Of the 120 preadolescents enrolled between 4.28.09 and 1.19.2010, 117 received preschool vaccinations between ages four and six years. The likelihood of being in the upper quartile of fear (VAS≥83) five years later increased with each additional same-day injection (OR=3.108, p=0.0100 95%CI=1.311, 7.367), but was not related to total lifetime or total four-to-six year injections. Only 12.5% (15) of parents reported anxiety about their preadolescents' vaccines (VAS>50). Parent and child anxiety was weakly correlated (r=0.15). Eight children in the upper fear quartile began their HPV series (26.67%) compared to 14 in the lower quartile (48.28% VASfear needles five years later. Preadolescent needle fear was a stronger predictor than parent vaccine anxiety of subsequent HPV vaccine uptake. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. High-pressure needle interface for thermoplastic microfluidics.

    Science.gov (United States)

    Chen, C F; Liu, J; Hromada, L P; Tsao, C W; Chang, C C; DeVoe, D L

    2009-01-07

    A robust and low dead volume world-to-chip interface for thermoplastic microfluidics has been developed. The high pressure fluidic port employs a stainless steel needle inserted into a mating hole aligned to an embedded microchannel, with an interference fit used to increase pressure resistance. Alternately, a self-tapping threaded needle screwed into a mating hole is also demonstrated. In both cases, the flat bottom needle ports seat directly against the microchannel substrate, ensuring low interfacial dead volumes. Low dispersion is observed for dye bands passing the interfaces. The needle ports offer sufficient pull-out forces for applications such as liquid chromatography that require high internal fluid pressures, with the epoxy-free interfaces compatible with internal microchannel pressures above 40 MPa.

  5. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  6. Human factors issues in fuel handling

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, J D; Iwasa-Madge, K M; Tucker, D A [Humansystems Inc., Milton, ON (Canada)

    1994-12-31

    The staff of the Atomic Energy Control Board wish to further their understanding of human factors issues of potential concern associated with fuel handling in CANDU nuclear power stations. This study contributes to that objective by analysing the role of human performance in the overall fuel handling process at Ontario Hydro`s Darlington Nuclear Generating Station, and reporting findings in several areas. A number of issues are identified in the areas of design, operating and maintenance practices, and the organizational and management environment. 1 fig., 4 tabs., 19 refs.

  7. The Problem of Metal Needles in Acupuncture-fMRI Studies

    Directory of Open Access Journals (Sweden)

    Florian Beissner

    2011-01-01

    Full Text Available Acupuncture is a therapy based on sensory stimulation of the human body by means of metal needles. The exact underlying mechanisms of acupuncture have not been clarified so far. Functional magnetic resonance imaging (fMRI has become an important tool in acupuncture research. Standard acupuncture needles, which are made of ferromagnetic steel, however, are problematic in acupuncture-fMRI studies for several reasons, such as attraction by the scanner's magnetic field, significant image distortions and signal-dropouts, when positioned close to the head or even heating due to absorption of radio frequency (RF. The aim of this study was to compare two novel types of acupuncture needles with a standard needle for their effect on MRI image quality. The standard needle severely reduced image quality, when located inside the RF coil. The nonferromagnetic metal needle may pose a risk due to RF heating, while the plastic needle has a significantly larger diameter. In conclusion, our recommendations are: (1 standard needles should not be used in MRI; (2 Nonferromagnetic metal needles seem to be the best choice for acupoints outside of the transmitter coil; and (3 only plastic needles are suited for points inside the coil. Laser acupuncture may be a safe alternative, too.

  8. Cellular Manufacturing System with Dynamic Lot Size Material Handling

    Science.gov (United States)

    Khannan, M. S. A.; Maruf, A.; Wangsaputra, R.; Sutrisno, S.; Wibawa, T.

    2016-02-01

    Material Handling take as important role in Cellular Manufacturing System (CMS) design. In several study at CMS design material handling was assumed per pieces or with constant lot size. In real industrial practice, lot size may change during rolling period to cope with demand changes. This study develops CMS Model with Dynamic Lot Size Material Handling. Integer Linear Programming is used to solve the problem. Objective function of this model is minimizing total expected cost consisting machinery depreciation cost, operating costs, inter-cell material handling cost, intra-cell material handling cost, machine relocation costs, setup costs, and production planning cost. This model determines optimum cell formation and optimum lot size. Numerical examples are elaborated in the paper to ilustrate the characterictic of the model.

  9. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  10. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  11. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    Science.gov (United States)

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  12. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    Directory of Open Access Journals (Sweden)

    Jaung-Geng Lin

    2013-01-01

    Full Text Available Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED, The National Center for Complementary and Alternative Medicine (NCCAM, and China National Knowledge Infrastructure (CNKI databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority.

  13. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  14. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  15. Laser-Controlled Growth of Needle-Shaped Organic Nanoaggregates

    DEFF Research Database (Denmark)

    Balzer, Frank; Rubahn, Horst-Günter

    2002-01-01

    Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometer....... While the orientation of the individual molecules in the needles is defined by the direction of surface dipoles, the localization on the surface, the length distribution as well as mutual distances can be adjusted via size and position of the laser focus spot.......Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometers...

  16. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  17. Quantification of Tissue Trauma following Insulin Pen Needle Insertions in Skin

    DEFF Research Database (Denmark)

    Jensen, Casper Bo; Larsen, Rasmus; Vestergaard, Jacob Schack

    Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop a computa......Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop...... a computational method to quantify tissue trauma based on skin bleeding and immune response. Method: Two common sized pen needles of 28G (0.36mm) and 32G (0.23mm) were inserted into skin of sedated LYD pigs prior to termination. Four pigs were included and a total of 32 randomized needle insertions were conducted...... diameter. Conclusion: A computational and quantitative method has been developed to assess tissue trauma following insulin pen needle insertions. Application of the method is tested by conduction of a needle diameter study. The obtained quantitative measures of tissue trauma correlate positively to needle...

  18. An exploration of undergraduate nursing and physiotherapy students' views regarding education for patient handling.

    Science.gov (United States)

    Kneafsey, Rosie; Ramsay, Jill; Edwards, Helen; Callaghan, Helen

    2012-12-01

    To ascertain the views of undergraduate student nurses and physiotherapists regarding their education in patient handling. Musculo-skeletal injuries are an important cause of staff sickness absence and attrition from the nursing profession and are a recognised problem within the physiotherapy profession. Nurses and physiotherapists are at risk of musculo-skeletal injuries as a result of their role in assisting patients with movement. A questionnaire survey was undertaken of undergraduate nursing and physiotherapy students (n = 371) at one university. Most students agreed that university teaching about moving and handling prepared them for clinical practice (64%). Over a third reported that they had never undertaken a written moving and handling risk assessment in clinical practice (38%). Almost half of the sample (40%) admitted undertaking unsafe moving and handling activities. Half (50%) also stated that they would rather 'fit' into the team than challenge unsafe practice. Almost a third (29%) stated that they had begun to experience pain since becoming a student. There were significant differences between nursing and physiotherapy students. Physiotherapy students were more likely to report being supervised when moving and handling and reported being more assertive about adhering to safe practice. The well-being of both nursing and physiotherapy undergraduate students is threatened when students undertake work placements in clinical settings. University-based education in safe patient handling, though important, can be undermined by workplace settings where unsafe practices occur. Collaboration is needed between university educators, managers and practice-based mentors to support students to maintain safe approaches to moving and handling patients. A third of students reported developing pain since becoming a healthcare student. Students entering their professions already injured may leave the workforce owing to poor physical well-being. It is vital that the

  19. European Model Code of safe practice in the storage and handling of petroleum products. Part I. Operations

    Energy Technology Data Exchange (ETDEWEB)

    1973-01-01

    This safe practice code was prepared by a working group consisting of experts from 10 Western European countries. It consists of short guidelines and technical advice on general precautions, injuries and medical services, permits to work, fire prevention and fighting, jetties, pipework, storage tanks, static electricity, electrical equipment, road vehicles, tank cars, handling of bitumen products, liquefied petroleum gases, packed products and training of personnel. The code is supplemented by 10 appendices, including a suggested syllabus for a 2-day course on fire prevention and emergency action for managers of oil installations.

  20. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2014-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility. PMID:21335868

  1. Approaches to the design of clean air handling facilities for radiopharmaceuticals

    International Nuclear Information System (INIS)

    2000-01-01

    Manufacturing, handling and administering processes of radiopharmaceuticals have to meet the requirements of both the fields viz. ''radio'' activity and ''pharma'' activity. Both these fields often dictate conflicting requirements. A step by step analysis of these conflicts can lead to practices reasonably acceptable to both the fields. The design approaches include engineering concepts of radiation protection, concepts and practices for pharmaceuticals, biologically unsafe products/processes and manufacturing, handling and administering processes of radiopharmaceuticals

  2. Structure and photoluminescence properties of Ag-coated ZnO nano-needles

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiaozhu, E-mail: Lixiaozhu1019@21cn.com [Department of Physics, Shaoguan University, Shaoguan, Guangdong 512005 (China) and Department of Physics and Key Laboratory of Acoustic and Photonic Materials and Devices of Ministry of Education, Wuhan University, Wuhan, Hubei 430072 (China); Wang Yongqian [Engineering Research Center of Nano-Geomaterials of Ministry of Education (China University of Geosciences), Wuhan, Hubei 430074 (China)

    2011-05-12

    Highlights: > ZnO nano-needles were synthesized by thermal oxidation. > Their surfaces were coated with Ag by pulse electro-deposition technique. > The uncoated and coated ZnO nano-needles were characterized. > The results showed that the prepared ZnO nano-needles have been coated with Ag successfully. > The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the Ag-coated ZnO nano-needles can increase the absorption of UV light. - Abstract: A large number of zinc oxide (ZnO) nano-needles were synthesized by thermal oxidation of pure zinc. The surfaces of ZnO nano-needles were coated with a layer of Ag by pulse electro-deposition technique. The uncoated and coated ZnO nano-needles were characterized by using the X-ray diffraction and the scanning electron microscope (SEM). The results showed that the uncoated samples were close-packed hexagonal structure, which showed needle-like morphology. Their average diameter is about 40 nm, lengths up to 5 {mu}m. At the same time we observed that the prepared ZnO nano-needles have been coated with Ag successfully. The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the uncoated ZnO nano-needles have two fluorescence peaks at 388 nm and 470.8 nm, respectively, the relative intensity of 143.4 and 93.61; and the Ag-coated ZnO nano-needles showed a pair of strong peaks at 387.4 nm and 405.2 nm, the relative intensity of 1366 and 1305, respectively, indicating that the Ag-coated ZnO nano-needles can increase the absorption of UV light.

  3. Redefining NHS complaint handling--the real challenge.

    Science.gov (United States)

    Seelos, L; Adamson, C

    1994-01-01

    More and more organizations find that a constructive and open dialogue with their customers can be an effective strategy for building long-term customer relations. In this context, it has been recognized that effective complaint-contact handling can make a significant contribution to organizations' attempts to maximize customer satisfaction and loyalty. Within the NHS, an intellectual awareness exists that effective complaint/contact handling can contribute to making services more efficient and cost-effective by developing customer-oriented improvement initiatives. Recent efforts have focused on redefining NHS complaint-handling procedures to make them more user-friendly and effective for both NHS employees and customers. Discusses the challenges associated with opening up the NHS to customer feedback. Highlights potential weaknesses in the current approach and argues that the real challenge is for NHS managers to facilitate a culture change that moves the NHS away from a long-established defensive complaint handling practice.

  4. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  5. Possibilities of the chemical analysis of Scots pine (Pinus sylvestris) needles

    International Nuclear Information System (INIS)

    Viksna, A.

    1999-01-01

    Scots pine (Pinus sylvestris L.) is a good bio indicator. This species is widely distributed in Europe, including Latvia, is easily identified, and is used in bio indication studies. It is known that the concentrations of most elements in needles change with time. These changes are connected to the processes involved in the uptake, transportation, storage and retranslocation of the elements. Scots pine keeps their needles for several years (3 to 4 years) and are suitable for the study of time related processes. The chemical composition of pine needles is used for the study the deposition and impact of air pollutants. Coniferous needles are covered with epicuticular wax, which act as a trap for airborne deposits. A comparison of chemical composition of pine needles that were unwashed and washed with chloroform made it possible to distinguish which elements were on the needles and to evaluate the character of pollution. The most important stage of the analysis of pine needles is sampling. Nutrient concentrations in the needles of coniferous trees have been shown to vary with the needle age and tree age, the phase of the annual physiological cycle, availability of nutrients in the soil and needle position within the crown. It is very important to take representative sample for the analysis. In the current work the trace element concentrations of the single needle were analysed by electrothermal atomic absorption spectrometry (ETAAS) and total reflection X-ray spectrometry (TXRF). The results of analysis showed that concentration of some elements depends from the position of needle within branch for the same needle age class. The concentrations of trace elements in the single needles within main shoot were more or less constant compare with other order shoots at given needle age class. Some higher variations in the elemental concentrations between single needles were observed in the tip part of main shoot. The actual distribution of the elements within a needle has

  6. Robotic needle steering: design, modeling, planning, and image guidance

    NARCIS (Netherlands)

    Cowan, Noah J.; Goldberg, Ken; Chirikjian, Gregory S.; Fichtinger, Gabor; Alterovitz, Ron; Reed, Kyle B.; Kallem, Vinutha; Misra, Sarthak; Park, Wooram; Okamura, Allison M.; Rosen, Jacob; Hannaford, Blake; Satava, Richard M.

    2010-01-01

    This chapter describes how advances in needle design, modeling, planning, and image guidance make it possible to steer flexible needles from outside the body to reach specified anatomical targets not accessible using traditional needle insertion methods. Steering can be achieved using a variety of

  7. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  8. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  9. Consumer food handling in the home: a review of food safety studies.

    Science.gov (United States)

    Redmond, Elizabeth C; Griffith, Christopher J

    2003-01-01

    Epidemiological data from Europe, North America, Australia, and New Zealand indicate that a substantial proportion of foodborne disease is attributable to improper food preparation practices in consumers' homes. International concern about consumer food safety has prompted considerable research to evaluate domestic food-handling practices. The majority of consumer food safety studies in the last decade have been conducted in the United Kingdom and Northern Ireland (48%) and in the United States (42%). Surveys (questionnaires and interviews), the most frequent means of data collection, were used in 75% of the reviewed studies. Focus groups and observational studies have also been used. One consumer food safety study examined the relationship between pathogenic microbial contamination from raw chicken and observed food-handling behaviors, and the results of this study indicated extensive Campylobacter cross-contamination during food preparation sessions. Limited information about consumers' attitudes and intentions with regard to safe food-handling behaviors has been obtained, although a substantial amount of information about consumer knowledge and self-reported practices is available. Observation studies suggest that substantial numbers of consumers frequently implement unsafe food-handling practices. Knowledge, attitudes, intentions, and self-reported practices did not correspond to observed behaviors, suggesting that observational studies provide a more realistic indication of the food hygiene actions actually used in domestic food preparation. An improvement in consumer food-handling behavior is likely to reduce the risk and incidence of foodborne disease. The need for the development and implementation of food safety education strategies to improve specific food safety behaviors is reviewed in this paper.

  10. NUTRIENTS CONCENTRATION AND RETRANSLOCATION IN THE Pinus taeda L. NEEDLES

    Directory of Open Access Journals (Sweden)

    Márcio Viera

    2010-03-01

    Full Text Available Aiming at evaluating nutrients concentration and retranslocation in the Pinus taeda L. needles, this study was developed in two stands, in native grass area and in second rotation area, with same species and same age (7.5 years old in Cambará do Sul, RS. The needles were collected in plants in four orthogonal points (South, North, East and West, sampled new needles, mature needles and old needles. The material was dried in a stove, milled and chemically analyzed (macro and micronutrients. The concentrations of N, P, K, B, Cu and Zn had decreased, of Ca, Fe and Mn increased, and the Mg and S have remained constant with the age of the needles. The retranslocation rate (old-new needles was more than 50% for most nutrients, except for Mn and Fe, showed that cumulative effect and the Ca reference element.

  11. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  12. Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance

    Science.gov (United States)

    Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.

    2017-01-01

    Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026

  13. A navigation system for percutaneous needle interventions based on PET/CT images: design, workflow and error analysis of soft tissue and bone punctures.

    Science.gov (United States)

    Oliveira-Santos, Thiago; Klaeser, Bernd; Weitzel, Thilo; Krause, Thomas; Nolte, Lutz-Peter; Peterhans, Matthias; Weber, Stefan

    2011-01-01

    Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well

  14. Structure and photoluminescence properties of Ag-coated ZnO nano-needles

    International Nuclear Information System (INIS)

    Li Xiaozhu; Wang Yongqian

    2011-01-01

    Highlights: → ZnO nano-needles were synthesized by thermal oxidation. → Their surfaces were coated with Ag by pulse electro-deposition technique. → The uncoated and coated ZnO nano-needles were characterized. → The results showed that the prepared ZnO nano-needles have been coated with Ag successfully. → The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the Ag-coated ZnO nano-needles can increase the absorption of UV light. - Abstract: A large number of zinc oxide (ZnO) nano-needles were synthesized by thermal oxidation of pure zinc. The surfaces of ZnO nano-needles were coated with a layer of Ag by pulse electro-deposition technique. The uncoated and coated ZnO nano-needles were characterized by using the X-ray diffraction and the scanning electron microscope (SEM). The results showed that the uncoated samples were close-packed hexagonal structure, which showed needle-like morphology. Their average diameter is about 40 nm, lengths up to 5 μm. At the same time we observed that the prepared ZnO nano-needles have been coated with Ag successfully. The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the uncoated ZnO nano-needles have two fluorescence peaks at 388 nm and 470.8 nm, respectively, the relative intensity of 143.4 and 93.61; and the Ag-coated ZnO nano-needles showed a pair of strong peaks at 387.4 nm and 405.2 nm, the relative intensity of 1366 and 1305, respectively, indicating that the Ag-coated ZnO nano-needles can increase the absorption of UV light.

  15. Robust path planning for flexible needle insertion using Markov decision processes.

    Science.gov (United States)

    Tan, Xiaoyu; Yu, Pengqian; Lim, Kah-Bin; Chui, Chee-Kong

    2018-05-11

    Flexible needle has the potential to accurately navigate to a treatment region in the least invasive manner. We propose a new planning method using Markov decision processes (MDPs) for flexible needle navigation that can perform robust path planning and steering under the circumstance of complex tissue-needle interactions. This method enhances the robustness of flexible needle steering from three different perspectives. First, the method considers the problem caused by soft tissue deformation. The method then resolves the common needle penetration failure caused by patterns of targets, while the last solution addresses the uncertainty issues in flexible needle motion due to complex and unpredictable tissue-needle interaction. Computer simulation and phantom experimental results show that the proposed method can perform robust planning and generate a secure control policy for flexible needle steering. Compared with a traditional method using MDPs, the proposed method achieves higher accuracy and probability of success in avoiding obstacles under complicated and uncertain tissue-needle interactions. Future work will involve experiment with biological tissue in vivo. The proposed robust path planning method can securely steer flexible needle within soft phantom tissues and achieve high adaptability in computer simulation.

  16. A support system in virtual reality for effective hyperthermia treatments. Heating properties of needle applicator for brain tumors

    International Nuclear Information System (INIS)

    Shindo, Yasuhiro; Iseki, Yuya; Nakane, Kazuya; Mimoto, Naoki; Kubo, Mitsunori; Kato, Kazuo; Takahashi, Hideaki; Uzuka, Takeo; Fujii, Yukihiko

    2011-01-01

    This paper describes the effectiveness of the developed simulator system for performing an effective hyperthermia treatment with a needle applicator in virtual reality (VR). The human brain is protected by the skull, which makes it difficult to non-invasively heat deep brain tumors with electromagnetic energy. Generally, needle applicators were used in clinical practice to heat brain tumors. However, some problems exist. One is that this heating method has a small heating area around the needle. In order to expand the heating area of a needle applicator, we developed a new type of needle applicator made from a shape memory alloy (SMA). The thermal properties of the SMA were checked experimentally using the developed heating system. As a result, the proposed needle applicator made of SMA is useful to create a wider heating area inside a tumor. Another problem is that medical doctors find it difficult to put a needle applicator into a target point inside of tumors. Therefore, a support system for performing an effective hyperthermia treatment is required in the clinic. In this paper, first, we constructed an anatomical 3-D model from magnetic resonance imaging (MRI) and X-ray computed tomography (CT) images by using 3-D computer aided design (CAD) software. Second, we presented the finite element method (FEM) model which is divided into non-linear elements on 3-D computer graphics (CG). Finally, we calculated temperature distributions using the 3-D FEM model with blood perfusion during hyperthermia treatments. From these results, it was found that the proposed VR system is effective for performing hyperthermia treatments. (author)

  17. [Doctor HUANG Shi-ping's acupuncture with golden needles].

    Science.gov (United States)

    Chen, Teng-Fei; Ma, Zeng-Bin; Xin, Si-Yuan; Zhu, Jiang

    2013-08-01

    Taking Doctor HUANG Shi-ping as the representative, the school of Huang's golden needle is based on Chinese martial art. Golden needles are adopted as main tool. Attaching great importance on the combination of acupuncture and moxibustioin, it is also characterized with penetrating needling with long needles. Through the development of three generations, it once outshone other schools in the field of acupuncture, and became famous all over the world. It made great contribution to the development of the course of acupuncture. However, with the development of the history, the form of acupuncture education as well as apparatus were all undergone an unified reform. Therefore, Doctor HUANG Shi-ping's acupuncture school be lost gradually.

  18. Diagenesis of conifer needles in a coastal marine environment

    Science.gov (United States)

    Hedges, John I.; Weliky, K.

    1989-10-01

    Physically intact fir, hemlock and cedar needles were isolated from different horizons of a sediment core from a coastal marine bay (Dabob Bay, Washington State, U.S.A.) and from nearby trees and forest litter. Green fir, hemlock and cedar needles were all characterized by glucose-rich aldose mixtures (~30% of tissue carbon), the production of vanillyl and cinnamyl CuO-derived phenols (~8% of tissue carbon) and the presence of both pinitol and myo-inositol (1-2% of tissue carbon). Needles from forest litter were enriched in lignin phenols and non-glucose aldoses and depleted in glucose and cyclitols. The sediment core contained an average of 10 mg/1 of physically intact fir, hemlock and cedar needles, which occurred in similar relative abundances and accounted for less than 1% of the total nonwoody gymnosperm tissue. Compared to the green and litter counterparts, all sedimentary needles were greatly depleted in cyclitols, glucose and p-coumaric acid and enriched in vanillyl phenol precursors. The degree of elevation of vanillyl phenol yield from the degraded needles was used to estimate minimal carbon losses from the samples, which ranged from near 40% for needle litter to almost 70% for the deepest (~100 years old) sedimentary fir/hemlock samples. Although downcore increases in carbon loss and refractory organic components indicated in situ diagenesis, the bulk of overall degradation occurred either on land or during the first 10-20 years after deposition. Atomic C/N ratios of degraded needles were lower than for green counterparts, but nitrogen was lost overall. These relative changes indicate the following stability series: vanillyl phenols > N > ferulic acid, p-hydroxy phenols, most aldoses and bulk tissue > glucose and p-coumaric acid > cyclitols (near 100% loss). Vanillic acid to vanillin ratios, (Ad/Al)v, of the green fir and hemlock needles were unusually high (0.36-0.38) and decreased downcore. Diagenesis also decreased the cinnamyl/vanillyl phenol ratio

  19. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  20. Rooting of needle fascicles from western white pine seedlings

    Science.gov (United States)

    Ramond J. Hoff; Geral I. McDonald

    1968-01-01

    In one test, 45 out of 318 (14 percent) needle fascicles from 2-year-old seedlings of Pinus monticola Dougl. were rooted. Eight of the needle fascicles produced shoot growth. In another test, 392 out of 742 (53 percent) needle fascicles were rooted, but none of these produced shoot growth.

  1. Harvesting and handling agricultural residues for energy

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, B.M.; Summer, H.R.

    1986-05-01

    Significant progress in understanding the needs for design of agricultural residue collection and handling systems has been made but additional research is required. Recommendations are made for research to (a) integrate residue collection and handling systems into general agricultural practices through the development of multi-use equipment and total harvest systems; (b) improve methods for routine evaluation of agricultural residue resources, possibly through remote sensing and image processing; (c) analyze biomass properties to obtain detailed data relevant to engineering design and analysis; (d) evaluate long-term environmental, social, and agronomic impacts of residue collection; (e) develop improved equipment with higher capacities to reduce residue collection and handling costs, with emphasis on optimal design of complete systems including collection, transportation, processing, storage, and utilization; and (f) produce standard forms of biomass fuels or products to enhance material handling and expand biomass markets through improved reliability and automatic control of biomass conversion and other utilization systems. 118 references.

  2. Needle Decompression of Tension Pneumothorax with Colorimetric Capnography.

    Science.gov (United States)

    Naik, Nimesh D; Hernandez, Matthew C; Anderson, Jeff R; Ross, Erika K; Zielinski, Martin D; Aho, Johnathon M

    2017-11-01

    The success of needle decompression for tension pneumothorax is variable, and there are no objective measures assessing effective decompression. Colorimetric capnography, which detects carbon dioxide present within the pleural space, may serve as a simple test to assess effective needle decompression. Three swine underwent traumatically induced tension pneumothorax (standard of care, n = 15; standard of care with needle capnography, n = 15). Needle thoracostomy was performed with an 8-cm angiocatheter. Similarly, decompression was performed with the addition of colorimetric capnography. Subjective operator assessment of decompression was recorded and compared with true decompression, using thoracoscopic visualization for both techniques. Areas under receiver operating curves were calculated and pairwise comparison was performed to assess statistical significance (P pneumothorax, that is, the absence of any pathologic/space-occupying lesion, in 100% of cases (10 of 10 attempts). Standard of care needle decompression was detected by operators in 9 of 15 attempts (60%) and was detected in 3 of 10 attempts when tension pneumothorax was not present (30%). True decompression, under direct visualization with thoracoscopy, occurred 15 of 15 times (100%) with capnography, and 12 of 15 times (80%) without capnography. Areas under receiver operating curves were 0.65 for standard of care and 1.0 for needle capnography (P = .002). Needle decompression with colorimetric capnography provides a rapid, effective, and highly accurate method for eliminating operator bias for tension pneumothorax decompression. This may be useful for the treatment of this life-threatening condition. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  3. Improving safety-related knowledge, attitude and practices of nurses handling cytotoxic anticancer drug: pharmacists' experience in a general hospital, Malaysia.

    Science.gov (United States)

    Keat, Chan Huan; Sooaid, Nor Suhada; Yun, Cheng Yi; Sriraman, Malathi

    2013-01-01

    An increasing trend of cytotoxic drug use, mainly in cancer treatment, has increased the occupational exposure among the nurses. This study aimed to assess the change of nurses' safety-related knowledge as well as attitude levels and subsequently to assess the change of cytotoxic drug handling practices in wards after a series of pharmacist-based interventions. This prospective interventional study with a before and after design requested a single group of 96 nurses in 15 wards actively providing chemotherapy to answer a self-administered questionnaire. A performance checklist was then used to determine the compliance of all these wards with the recommended safety measures. The first and second assessments took 2 months respectively with a 9-month intervention period. Pharmacist-based interventions included a series of technical, educational and administrative support measures consisting of the initiation of closed-system cytotoxic drug reconstitution (CDR) services, courses, training workshops and guideline updates. The mean age of nurses was 32.2∓6.19 years. Most of them were female (93.8%) and married (72.9%). The mean knowledge score of nurses was significantly increased from 45.5∓10.52 to 73.4∓8.88 out of 100 (p<0.001) at the end of the second assessment. Overall, the mean practice score among the wards was improved from 7.6∓5.51 to 15.3∓2.55 out of 20 (p<0.001). The pharmacist-based interventions improved the knowledge, attitude and safe practices of nurses in cytotoxic drug handling. Further assessment may help to confirm the sustainability of the improved practices.

  4. The longitudinal distribution of elements in developing and aging scots pine needles

    International Nuclear Information System (INIS)

    Viksna, A.; Helmisaari, H.S.; Standzenieks, P.; Lindgren, E.S.

    2001-01-01

    Needle or leaf nutrient concentrations are commonly used for analysing tree nutritional status for e.g. estimating possible nutrient deficiencies or unbalances. The practise used e.g. in northern Europe is to sample needles during the dormant period from either the current or in some cases several needle age classes from a fixed position of a number of trees in a stand. The sampled needles are then dried and ground for nutrient analysis. The sampling aims to minimise the spatial and temporal variation in needle nutrient concentrations for estimating the availability of nutrients in soil through needle analysis. It is well known that the concentrations of different nutrients vary in needles with the phase of the annual physiological cycle (Fife and Nambiar 1982, 1984), needle age (Florence and Chuoung 1974, Madgwick et al. 1983) and sampling position (Helmisaari 1992). The samples analysed are usually bulk samples of a large number of needles, and the results are mean concentrations representing an age class in a stand. There is little information on how different needles vary in nutrient concentrations, and even less on how nutrient concentrations vary within individual needles. The import and export of elements to and from needles varies according to the developmental phase of needles, and is likely to affect the element concentrations in different parts of the needles. Accordingly, the elemental concentrations measured in different parts of the needles may give an insight into the transport pattern of an element and its potential mobility. Up to now, very few studies report needle element concentrations in different parts of the needles, e.g. tip, base and middle (Giertych et al. 1997), or in different parts of the leaf phloem (Eschrich et al. 1988). The aim of this study was to determine the distribution of different elements along the length of single Scots pine needles of different age and during different stages of needle physiological cycle. The scanning

  5. Sugar export limits size of conifer needles

    DEFF Research Database (Denmark)

    Rademaker, Hanna; Zwieniecki, Maciej A.; Bohr, Tomas

    2017-01-01

    Plant leaf size varies by more than three orders of magnitude, from a few millimeters to over one meter. Conifer leaves, however, are relatively short and the majority of needles are no longer than 6 cm. The reason for the strong confinement of the trait-space is unknown. We show that sugars...... does not contribute to sugar flow. Remarkably, we find that the size of the active part does not scale with needle length. We predict a single maximum needle size of 5 cm, in accord with data from 519 conifer species. This could help rationalize the recent observation that conifers have significantly...

  6. How to handle topography in practical geoid determination: three examples

    DEFF Research Database (Denmark)

    Omang, O.C.D.; Forsberg, René

    2000-01-01

    Three different methods of handling topography in geoid determination were investigated. The first two methods employ the residual terrain model (RTM) remove-restore technique, yielding the quasi-geoid, whereas the third method uses the classical Helmert condensation method, yielding the geoid. All...

  7. CUDA accelerated simulation of needle insertions in deformable tissue

    International Nuclear Information System (INIS)

    Patriciu, Alexandru

    2012-01-01

    This paper presents a stiff needle-deformable tissue interaction model. The model uses a mesh-less discretization of continuum; avoiding thus the expensive remeshing required by the finite element models. The proposed model can accommodate both linear and nonlinear material characteristics. The needle-deformable tissue interaction is modeled through fundamental boundaries. The forces applied by the needle on the tissue are divided in tangent forces and constraint forces. The constraint forces are adaptively computed such that the material is properly constrained by the needle. The implementation is accelerated using NVidia CUDA. We present detailed analysis of the execution timing in both serial and parallel case. The proposed needle insertion model was integrated in a custom software that loads DICOM images, generate the deformable model, and can simulate different insertion strategies.

  8. Precision grid and hand motion for accurate needle insertion in brachytherapy

    International Nuclear Information System (INIS)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J.

    2011-01-01

    Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2 3 factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

  9. Inserting needles into the body: a meta-analysis of brain activity associated with acupuncture needle stimulation.

    Science.gov (United States)

    Chae, Younbyoung; Chang, Dong-Seon; Lee, Soon-Ho; Jung, Won-Mo; Lee, In-Seon; Jackson, Stephen; Kong, Jian; Lee, Hyangsook; Park, Hi-Joon; Lee, Hyejung; Wallraven, Christian

    2013-03-01

    Acupuncture is a therapeutic treatment that is defined as the insertion of needles into the body at specific points (ie, acupoints). Advances in functional neuroimaging have made it possible to study brain responses to acupuncture; however, previous studies have mainly concentrated on acupoint specificity. We wanted to focus on the functional brain responses that occur because of needle insertion into the body. An activation likelihood estimation meta-analysis was carried out to investigate common characteristics of brain responses to acupuncture needle stimulation compared to tactile stimulation. A total of 28 functional magnetic resonance imaging studies, which consisted of 51 acupuncture and 10 tactile stimulation experiments, were selected for the meta-analysis. Following acupuncture needle stimulation, activation in the sensorimotor cortical network, including the insula, thalamus, anterior cingulate cortex, and primary and secondary somatosensory cortices, and deactivation in the limbic-paralimbic neocortical network, including the medial prefrontal cortex, caudate, amygdala, posterior cingulate cortex, and parahippocampus, were detected and assessed. Following control tactile stimulation, weaker patterns of brain responses were detected in areas similar to those stated above. The activation and deactivation patterns following acupuncture stimulation suggest that the hemodynamic responses in the brain simultaneously reflect the sensory, cognitive, and affective dimensions of pain. This article facilitates a better understanding of acupuncture needle stimulation and its effects on specific activity changes in different brain regions as well as its relationship to the multiple dimensions of pain. Future studies can build on this meta-analysis and will help to elucidate the clinically relevant therapeutic effects of acupuncture. Copyright © 2013 American Pain Society. All rights reserved.

  10. Peribulbar block in equine isolated heads. Development of a single needle technique and tomographic evaluation

    Directory of Open Access Journals (Sweden)

    vanessa rabbogliatti

    2017-05-01

    Full Text Available Peribulbar block (PPB has been used in humans as a safer alternative to retrobulbar block (RBB. PBB, depends on the diffusion of anaesthetic solution into the muscle across the connective tissue and it is performed introducing the needle within the extraconal space. The advantages are fewer complications and palpebral akinesia. In Veterinary Medicine few studies describe this technique in dogs (Ahn J 2013 and cats (Shilo-Benjamini et al. 2013. Based on literature the aim of the study is to determinate, in equine specimens, feasibility of inferior PBB with single needle injection, by using contrast medium (CM, and to evaluate thought Computed Tomography (CT the distribution around the optic nerve (degrees. PBB was performed in 6 orbits. The mixture injected consisted of 20 ml of physiological solution and iodinated CM at 25%. Each periorbital area underwent three CT scans. A basal acquisition to assess the needle position before the injection, a second and third scan were performed immediately after injection, and after application of pressure on the periorbital surface area to promote CM diffusion. The needle position was measured from the tip to the optic nerve with a mean distance of 2,27 mm ± 0,28. The mean volume distribution before pressure application was 23,56 cm3 ± 2,58 and after pressure application was 27,56 cm3 ± 4,8.  The CM distribution, was defined (Nouvellon et al. 2010 “successful” in 4 orbits (>270° and “inadequate” in 2 orbits (<180°. The present study demonstrates feasibility of inferior PBB by single injection in horses for its simple and practical execution. Inferior PPB is a potential alternative to systemic administration of neuromuscular blocking agents for ophthalmic surgery. However, this approach needs to be evaluate in clinical trials to assess its feasibility and effectiveness in clinical practice for standing procedures.

  11. Regulatory inspection practices for industrial safety (electrical, mechanical, material handling and conventional aspects)

    International Nuclear Information System (INIS)

    Agarwal, K.

    2017-01-01

    Regulatory Inspection (RI) of BARC facilities and projects are carried out under the guidance of BARC Safety Council (BSC) Secretariat. Basically facilities and projects have been divided into two board categories viz. radiological facilities and non-radiological facilities. The Rls of radiological facilities should be carried out under OPSRC and of non-radiological facilities under CFSRC. Periodicity of inspection shall be at least once in a year. The RI of projects is carried out under concerned DSRC. RI practices with industrial safety which includes electrical, mechanical, material handling and conventional aspect for these facilities starts with check lists. The inspection areas are prepared in the form of checklists which includes availability of approved documents, compliance status of previous RIT and various safety committee's recommendations, radiological status of facilities, prompt reporting of safety related unusual occurrences, major incident, site visit for verification of actual status of system/plant. The practices for inspection in the area of electrical safety shall include checking of maintenance procedure for all critical class IV system equipment's such as HT panel, LT panel, transformer and motors. Load testing of Class III system such as D.G. set etc. shall be carried out as technical specification surveillance schedule. Status of aviation lights, number of qualified staff, availability of qualified staff etc. shall be form of inspection

  12. Sharing of Needles and Syringes among Men Who Inject Drugs: HIV Risk in Northwest Bangladesh.

    Directory of Open Access Journals (Sweden)

    M Kamal Pasa

    Full Text Available Injection drug use is prevalent in northwestern Bangladesh. We sought to explore the context of needle/syringe sharing among persons who inject drugs (PWID, examining risk exposures to blood-borne infections like the human immunodeficiency virus (HIV and hepatitis in a region where these dual epidemics are likely to expand.We used a qualitative research approach to learn about injection practices, conducting 60 in-depth interviews among PWID. We then conducted 12 focus group discussions (FGDs that generated a checklist of salient issues, and followed up with personal observations of typical days at the drug-use venues. Content and interpretative frameworks were used to analyze qualitative information and socio-demographic information, using SPSS software.We found that needle/syringe-sharing behaviours were integrated into the overall social and cultural lives of drug users. Sharing behaviours were an central component of PWID social organization. Sharing was perceived as an inherent element within reciprocal relationships, and sharing was tied to beliefs about drug effects, economic adversity, and harassment due to their drug user status. Carrying used needles/syringes to drug-use venues was deemed essential since user-unfriendly needle-syringe distribution schedules of harm reduction programmes made it difficult to access clean needles/syringes in off-hours. PWID had low self-esteem. Unequal power relationships were reported between the field workers of harm reduction programmes and PWID. Field workers expressed anti-PWID bias and judgmental attitudes, and also had had misconceptions about HIV and hepatitis transmission. PWID were especially disturbed that no assistance was forthcoming from risk reduction programme staff when drug users manifested withdrawal symptoms.Interventions must take social context into account when scaling up programmes in diverse settings. The social organization of PWID include values that foster needle

  13. Does the effect of acupuncture depend on needling sensation and manipulation?

    Science.gov (United States)

    Choi, Yu-Jin; Lee, Jae-Eun; Moon, Won-Kyung; Cho, Seung-Hun

    2013-06-01

    Acupuncture sensation and manipulation have been considered to be an important component of acupuncture in traditional Asian medicine. However, there has been limited research as to whether acupuncture sensation is associated with therapeutic benefit. This study investigated the relationship between acupuncture sensation and analgesic effect according to acupuncture manipulation. Fifty-three healthy volunteers received three different forms of acupuncture in a single-blinded crossover design: superficial needling (0.3 cm), deep needling (2 cm) and needling with bi-directional rotation. The effects of acupuncture were evaluated by using the pressure pain threshold. Acupuncture sensation measurement was done in two ways. Both total acupuncture sensation and increase of the pressure pain threshold were maximum in needling with rotation, followed by deep needling and superficial needling. Repeated-measure analysis of variance (ANOVA) analysis was carried out to assess whether there was a significant difference; both showed significant difference (p = 0.000, 0.003). A paired sample t-test was carried out, which revealed that needling with rotation showed significant difference from both superficial needling and deep needling. Further, the correlation between the total acupuncture sensation and changes in pressure pain threshold were calculated using Pearson correlation; there was a significant correlation (p = 0.002, p = 0.013). Acupuncture sensation and pressure pain threshold increase according to the depth and rotation of acupuncture. Especially, both display significant increase with needle rotation. Further, there is a significant correlation between acupuncture needling sensation and increase in pressure pain threshold. It seems that needle rotation and acupuncture sensation play an important role in verifying the effect of acupuncture. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  15. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  16. Evaluation of heat transfer in acupuncture needles: convection and conduction approaches.

    Science.gov (United States)

    Tzou, Chieh-Han John; Yang, Tzyy-Yih; Chung, Ya-Chien

    2015-04-01

    Originating in ancient China, acupuncture using needles has been developed for thousands of years and has received attention for its reported medical remedies, such as pain relief and chronic disease treatment. Heat transfer through the needles, which might have effects on the biomechanism of acupuncture, providing a stimulus and regulating homeostasis, has never been studied. This article analyzes the significance of heat transfer through needles via convection and conduction, approached by means of computational analysis. The needle is a cylindrical body, and an axis symmetrical steady-state heat-transfer model that viscosity and static pressure was not applied. This article evaluates heat transfer via acupuncture needles by using five metal materials: silver, copper, brass, iron, and stainless steel. A silver needle of the type extensively applied in acupuncture can dissipate more than seven times as much heat as a stainless steel needle of the same type. Heat transfer through such a needle is significant, compared to natural body-energy consumption over a range of ambient temperatures. The mechanism by which heat flows in or out of the body through the needles may be crucial in the remedial efficacy of acupuncture. Copyright © 2015. Published by Elsevier B.V.

  17. Return Rates for Needle Exchange Programs: A Common Criticism Answered

    Directory of Open Access Journals (Sweden)

    Ksobiech Kate

    2004-04-01

    Full Text Available Abstract This study searched the available needle exchange program (NEP literature for return rate data. A total of 26 articles were found. The overall worldwide return rate was 90%, although this ranged from a low of 15% to a high of 112%. U.S. NEP return rates were gathered from only eight studies, indicating a clear need for more data, although U.S. return rates were comparable to those from NEPs outside of the U.S. One underlying assumption made by opponents of NEPs is that IDUs will not return needles to the distribution site, thereby potentially increasing the risk of health problems to the surrounding community from exposure to contaminated needles. This study's results suggest that NEPs are relatively successful in taking in used needles, although it is generally unclear where the needles were originally acquired, and if IDUs return their own needles, or are returning needles for a social network. Ways for AIDS Service Organizations to capitalize on these brief encounters with IDUs, as well as public policy implications of the findings, are discussed.

  18. In vivo Monitoring of Serotonin by Nanomaterial Functionalized Acupuncture Needle

    Science.gov (United States)

    Li, Yu-Tao; Tang, Li-Na; Ning, Yong; Shu, Qing; Liang, Feng-Xia; Wang, Hua; Zhang, Guo-Jun

    2016-06-01

    Acupuncture treatment is amazing but controversial. Up to now, the mechanism of treating diseases by acupuncture and moxibustion is still unclear, especially the occurrence of the molecular events in local acupoints. Herein, we report an extremely stable microsensor by modifying carbon nanotube (CNT) to the tip surface of acupuncture needle and applying this CNT-modified acupuncture needle for real time monitoring of serotonin (5-HT) in vivo. To stabilize CNT modification on the needle tip surface, poly(3,4-ethylenedioxythiophene)(PEDOT) was employed as glue water to stick CNT on the needle. The detection limit of the CNT-modified needle was found to be approximately 50 nM and 78 nM in the PBS and the cell medium, respectively. In addition, the needle showed good selectivity to some inflammatory mediators and some electroactive molecules. For the first time, the CNT-modified needle could be directly probed into rat body for real time monitoring of 5-HT in vivo, showing a great potential for better understanding the mechanism of acupuncture treatment.

  19. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  20. Radiological safety aspects of handling plutonium

    International Nuclear Information System (INIS)

    Sundararajan, A.R.

    2016-01-01

    Department of Atomic Energy in its scheme of harnessing the nuclear energy for electrical power generation and strategic applications has given a huge role to utilization of plutonium. In the power production programme, fast reactors with plutonium as fuel are expected to play a major role. This would require establishing fuel reprocessing plants to handle both thermal and fast reactor fuels. So in the nuclear fuel cycle facilities variety of chemical, metallurgical, mechanical operations have to be carried out involving significant inventories of "2"3"9 Pu and associated radionuclides. Plutonium is the most radiotoxic radionuclide and therefore any facility handling it has to be designed and operated with utmost care. Two problems of major concern in the protection of persons working in plutonium handling facilities are the internal exposure to the operating personnel from uptake of plutonium and transplutonic nuclides as they are highly radiotoxic and the radiation exposure of hands and eye lens during fuel fabrication operations especially while handling recycled high burn up plutonium. In view of the fact that annual limit for intake is very small for "2"3"9Pu and its radiation emission characteristics are such that it is a huge challenge for the health physicists to detect Pu in air and in workers. This paper discusses the principles and practices followed in providing radiological surveillance to workers in plutonium handling areas. The challenges in protecting the workers from receiving exposures to hands and eye lens in handling high burn up plutonium are also discussed. The sites having Pu fuel cycle facilities should have trained medical staff to handle cases involving excessive intake of plutonium. (author)

  1. An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy

    International Nuclear Information System (INIS)

    Hong, J; Dohi, T; Hashizume, M; Konishi, K; Hata, N

    2004-01-01

    A real-time ultrasound-guided needle-insertion medical robot for percutaneous cholecystostomy has been developed. Image-guided interventions have become widely accepted because they are consistent with minimal invasiveness. However, organ or abnormality displacement due to involuntary patient motion may undesirably affect the intervention. The proposed instrument uses intraoperative images and modifies the needle path in real time by using a novel ultrasonic image segmentation technique. In phantom and volunteer experiments, the needle path updating time was 130 and 301 ms per cycle, respectively. In animal experiments, the needle could be placed accurately in the target

  2. Spruce needles used as radioecological biotracers

    International Nuclear Information System (INIS)

    Seidel, C.; Gruber, V.; Baumgartner, A.

    2009-01-01

    In a two years project spruce needle samples of the Austrian Bioindicator Grid were analysed by gamma-ray spectrometry to investigate the spatial and temporal distribution of radionuclides in spruce needles of the last 25 years with the main focus on the radioactive contamination before and after the Chernobyl fallout 1986. More than 600 spruce needle samples at selected locations of the Bioindicator Grid were analysed for different natural and anthropogenic radionuclides: 137 Cs, 40 K, 210 Pb, 226 Ra, 228 Ra, 238 U. Additionally, soil samples were taken at selected sites to study the soil-to-plant transfer. This radioecological evaluation is an important part of an existing environmental surveillance programme in Upper Austria in order to gain basic information on the impact of environmental changes on the radioecological behaviour of spruce trees. (orig.)

  3. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  4. Endoscopic ultrasound-guided fine-needle tissue acquisition - A review and update of literature

    Directory of Open Access Journals (Sweden)

    Benjamin Tharian

    2015-01-01

    Full Text Available Ever since the first endoscopic ultrasound-guided fine needle aspiration (FNA was done in 1992, the procedure has evolved to become an indispensable tool for tissue acquisition in patients with gastrointestinal tumors and periluminal lesions. With the growing evidence of neoadjuvant therapy and research into intratumoral therapy, the need to obtain tissue diagnosis for tumors is quite apparent. This review provides an overall perspective to the endosonographer on various issues that are a key for best practices in FNA, in addition to being an update for practicing experienced endosonographers.

  5. Laboratory biosafety for handling emerging viruses

    Directory of Open Access Journals (Sweden)

    I. Made Artika

    2017-05-01

    Full Text Available Emerging viruses are viruses whose occurrence has risen within the past twenty years, or whose presence is likely to increase in the near future. Diseases caused by emerging viruses are a major threat to global public health. In spite of greater awareness of safety and containment procedures, the handling of pathogenic viruses remains a likely source of infection, and mortality, among laboratory workers. There is a steady increase in both the number of laboratories and scientist handling emerging viruses for diagnostics and research. The potential for harm associated to work with these infectious agents can be minimized through the application of sound biosafety concepts and practices. The main factors to the prevention of laboratory-acquired infection are well-trained personnel who are knowledgable and biohazard aware, who are perceptive of the various ways of transmission, and who are professional in safe laboratory practice management. In addition, we should emphasize that appropriate facilities, practices and procedures are to be used by the laboratory workers for the handling of emerging viruses in a safe and secure manner. This review is aimed at providing researchers and laboratory personnel with basic biosafety principles to protect themselves from exposure to emerging viruses while working in the laboratory. This paper focuses on what emerging viruses are, why emerging viruses can cause laboratory-acquired infection, how to assess the risk of working with emerging viruses, and how laboratory-acquired infection can be prevented. Control measures used in the laboratory designed as such that they protect workers from emerging viruses and safeguard the public through the safe disposal of infectious wastes are also addressed.

  6. A high intensity beam handling system at the KEK-PS new experimental hall

    International Nuclear Information System (INIS)

    Tanaka, K.H.; Minakawa, M.; Yamanoi, Y.

    1991-01-01

    We would like to summarize newly developed technology for handling high-intensity beams. This was practically employed in the beam-handling system of primary protons at the KEK-PS new experimental hall. (author)

  7. [King Injo's disease and burnt needle therapy].

    Science.gov (United States)

    Kim, In-Sook

    2004-12-01

    This paper investigates an interrelationship between burnt needle therapy and King Injo's disease. From 1633 (Year 11 in King Injo's reign) to May 5, 1649 (Year 27 in King Injo's reign), right before his death, King Injo was treated with burnt needles by Yi Hyeongik, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have?Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon ear, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease. The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong derived from her mother, Queen Mother Inmok. Moral justification for King Injo's coup was Gwanghaegun or Prince Gwanghae's immoral conduct toward Queen Mothe Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant rebellions and treasons threatened King Injo. The king suspected that Queen Mother

  8. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  9. Tribological Characteristics of Flat Surfaces of Parts made of Baked ПА-ЖГр2 Material after Needle Milling

    Directory of Open Access Journals (Sweden)

    E. E. Feldshtejn

    2005-01-01

    Full Text Available The paper considers regularities of machined surface formation and its wear resistance in the process of needle milling of baked ПА-ЖГр2 material. Roughness of the machined surface is reduced as feed and tightness are increased. The surface being machined does not practically have pores and traces of single needle trajectories and rolls of deformed metal along their lateral sides are observed. Instant and average friction coefficients for various machining conditions differ approximately by 10 %, difference in relative solid surface wear is greater by 3 and more fold in accordance with machining conditions. The minimal intensity of surface wear process after needle milling is observed while machining it with minimal milling speed and feed and maximal tightness.

  10. [Research progress of needles with knife-edge for carotid cardiac syndrome].

    Science.gov (United States)

    Tan, Lingqiong; Zhao, Yanling

    2015-04-01

    According to topographic anatomy, pathogenesis and by retrieving, summarizing and analyzing literature regarding needle-knife and needles with knife-edge for carotid cardiac syndrome, it is found out that clinical misdiagnosis rate of carotid cardiac syndrome is considerably high. Needle-knife and needles with knife-edge could significantly improve the clinical symptoms of carotid cardiac syndrome, showing characteristic and advantage in treatment, but it is deficient in technique standard and efficacy criteria that should be united and authoritative. Researches regarding pathogenesis of carotid cardiac syndrome are not systematic. Clinical observation regarding long-term efficacy and relapse of needle-knife and needles with knife-edge treatment is rare. It is believed that the awareness on carotid cardiac syndrome should be increased to reduce misdiagnosis; scientific and standardized technique standard and efficacy criteria should be established; systematic and comprehensive researches regarding mechanism of needle-knife and needles with knife-edge for carotid cardiac syndrome should be launched; besides, clinical discussion regarding its long-term efficacy should start to provide a better clinical guideline.

  11. Generic Planning and Control of Automated Material Handling Systems: Practical Requirements Versus Existing Theroy.

    NARCIS (Netherlands)

    Haneyah, S.W.A.; Zijm, Willem H.M.; Schutten, Johannes M.J.; Schuur, Peter

    2011-01-01

    This paper discusses the problem of generic planning and control of Automated Material Handling Systems (AMHSs). The paper illustrates the relevance of this research direction, and then addresses three different market sectors where AMHSs are used. These market sectors are: baggage handling,

  12. Generic planning and control of automated material handling systems : practical requirements versus existing theory

    NARCIS (Netherlands)

    Haneyah, S.W.A.; Schutten, Johannes M.J.; Schuur, Peter; Zijm, Willem H.M.

    2013-01-01

    This paper discusses the problem to design a generic planning and control architecture for utomated material handling systems (AMHSs). We illustrate the relevance of this research direction, and then address three different market sectors where AMHSs are used, i.e., baggage handling, distribution,

  13. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  14. Exploring Reflective Means to Handle Plagiarism

    Science.gov (United States)

    Dalal, Nikunj

    2016-01-01

    Plagiarism has become widespread in the university teaching environment. This article presents practical wisdom from several years of experience handling plagiarism in two Information Systems (IS) courses with the exploratory use of reflective means such as dialogues and essays. There has been very little work on the use of reflective approaches…

  15. The Treatment of Verrucae Pedis Using Falknor’s Needling Method: A Review of 46 Cases

    Directory of Open Access Journals (Sweden)

    Belinda Longhurst

    2013-04-01

    Full Text Available Human Papilloma Virus (HPV related verrucae pedis persist, seemingly evading host immune surveillance, yet sometimes disappear with inflammation. The absence, or reduction, of a cellular immune response may explain why verrucae treatments are not uniformly successful and treatment can be difficult even in immune-competent individuals. Little investigation has been undertaken into the potential benefit and efficacy of needling verrucae, a treatment modality causing HPV infected keratinocyte destruction in addition to inducing an assumed enhanced immune response. A review of clinical practice is presented, reporting the treatment method and results of data collected from a retrospective review of 45 patients. Thirty-one (69% cases demonstrated complete resolution of verrucae following needling treatment. Three patients demonstrated reduction in size and pain whilst 11 showed no improvement. No adverse events were noted. Needling may have a place in the management of verrucae pedis in an adult population but a large scale study utilising objective measures and a control intervention would provide more detailed efficacy data along with a greater understanding of the effects of this treatment on long term immunity.

  16. Handling reality: three paths to understanding the knowledge society

    Directory of Open Access Journals (Sweden)

    Daniel Muriel

    2009-11-01

    Full Text Available The "knowledge society" hypothesis is a useful heuristic for understanding contemporary society after the crisis of modernity that arose in the second half of the 20th century.  I shall examine the ways in which reality can be handled (reality handlings, that is, all those material-semiotic practices  through which we try to influence the world that surrounds us. I shall focus especially on the epistemological problems of current scientific and political practices.  I conclude with three specific, but not mutually exclusive avenues that might (or might not help us fully articulate the idea of the "knowledge society": the modern-sociological, the actantial-articulative, and the genealogical.  

  17. [Special penetration needling for refractory peripheral facial paralysis].

    Science.gov (United States)

    Cao, Rongjuan; Qiu, Xiaohu; Xie, Xiaokun

    2018-03-12

    To observe the clinical effect difference between special penetration needling and conventional penetration needling for the refractory peripheral facial paralysis. A total of 97 patients with intractable facial paralysis were randomized into an observation group (49 cases and 2 dropping) and a control group (48 cases and 4 dropping). In the observation group, special penetration needling at an angle about 45° between the penetration needle and paralysis muscle bundle was used, Yangbai (GB 14) through Touwei (ST 8), Yangbai (GB 14) through Shangxing (GV 23), Sizhukong (TE 23) through Yuyao (EX-HN 4), Qianzhen (Extra) through Yingxiang (LI 20), mutual penetration between Yingxiang (LI 20) and Jiache (ST 6). Conventional penetration needling was applied in the control group, Yangbai (GB 14) through Yuyao (EX-HN 4), Cuanzhu (BL 2) through Yuyao (EX-HN 4), mutual penetration between Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) through Dicang (ST 4), Sibai (ST 2) through Yingxiang (LI 20). Three groups of electroacupuncture (discontinuous wave, 1 Hz) with tolerance were connected respectively in the two groups, Yangbai (GB 14) and Sizhukong (TE 23), Yangbai (GB 14) and Qianzheng (Extra), Yingxiang (LI 20) and Jiache (ST 6) in the observation group, Yangbai (GB 14) and Cuanzhu (BL 2), Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) and Sibai (ST 2) in the control group. TDP was applied in the two groups at the affected Yifeng (TE 17), Jiache (ST 6) and Qianzheng (Extra), which were around the ear. Perpendicular insertion was used at Yifeng (TE 17) at the affected side and Hegu (LI 4) at the healthy side and bilateral Zusanli (ST 36). The needles were retained for 30 min. The treatment was given for 3 courses, once a day and 10 days as a course, 5 days at the interval. House-Brackmann (H-B) facial nerve grading score was recorded before and after treatment. The clinical effects were compared. The H-B scores after treatment in the two groups were higher than

  18. Drug-related deaths and the sales of needles through pharmacies.

    Science.gov (United States)

    Davidson, Peter J; Martinez, Alexis; Lutnick, Alexandra; Kral, Alex H; Bluthenthal, Ricky N

    2015-02-01

    Providing needles to people who inject drugs is a well-proven public health response to the transmission of HIV and other blood borne viruses. Despite over a quarter of a century of research, new concerns about potential unintended negative consequences of needle distribution continue to emerge. Specifically, a claim was recently made that the introduction of pharmacy sales of needles was followed by an increase in overdoses in pharmacy parking lots. If true, this would have serious implications for the design of needle access programs, particularly those involving pharmacy sales of needles. We examine spatial relationships between drug-related deaths and pharmacies in Los Angeles County (population 9.8 million) before and after the 2007 enactment of a California law allowing pharmacy sales of needles without a prescription. Seven thousand and forty-nine drugs related deaths occurred in Los Angeles county from 2000 to 2009 inclusive. Four thousand two hundred and seventy-five of these deaths could be geocoded, and were found to be clustered at the census tract level. We used three methods to examine spatial relationships between overdose death locations and pharmacy locations for two years on either side of the enactment of the pharmacy sales law, and found no statistically significant changes. Among the 711 geocodable deaths occurring in the two years following the change in law, no death was found to occur within 50m of a pharmacy which sold needles. These results are consistent with prior studies which suggest pharmacy sales of needles improve access to needles without causing increased harms to the surrounding community. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. 78 FR 34589 - Descriptive Designation for Needle- or Blade-Tenderized (Mechanically Tenderized) Beef Products

    Science.gov (United States)

    2013-06-10

    ... that 15% of consumers changed their behavior based on reading safe handling instruction labels...-1325.) \\19\\ Bruhn (1997) shows that 17% of consumers changed their behavior based on reading safe... practices. Safe Handling Labels and Consumer Behavior in the Southern U.S. \\21\\ Cates, Sheryl C., Cignetti...

  20. Root canal debris removal using different irrigating needles: An SEM study

    Directory of Open Access Journals (Sweden)

    Sheetal Ghivari

    2011-01-01

    Full Text Available Aim: This study was carried out to compare the efficacy of three irrigating needle designs in removal of debris from different parts of the root canal. Materials and Methods: Thirty human maxillary canines were prepared using HERO Shaper rotary system and irrigated with 1 ml of 5.25% sodium hypochlorite (NaOCl after each instrument change. Three 25-gauge irrigation needle designs - brush-covered Navi Tip FX (Group I, side-vented needle RC Twents (Group II and single-beveled (Group III irrigating needles - were tested for their efficiency in debris removal in three different parts of the root canal (n=10 canals per group. Following instrumentation, the roots were vertically sectioned and divided into coronal, middle and apical thirds for observation under scanning electron microscope (×200 magnification. Debris on the canal wall was evaluated by using a four-scale scoring system described by Paque and his co-workers. Results: The canals irrigated with brush-covered needle Navi Tip FX (Group I showed lower average debris score, indicating greater removal of debris in coronal third as compared to middle and apical thirds, whereas the canals irrigated with side-vented needle (Group II and single-beveled needle (Group III exhibited lower average score in the middle third than coronal and apical thirds. All the three needle designs exhibited higher debris score in apical third of the root canal. Tukey multiple comparisons test was applied at a significance level of P>0.05. A statistically significant difference (P<0.05 was observed in the debris removal in the coronal and middle thirds of root canals irrigated with brush-covered Navi Tip FX (Group I and side-vented (Group II needles, respectively, when compared with other needle design groups. Conclusion: Within the limitations of this study, it can be concluded that all the needle designs tested were effective in certain regions of the root canal with apical third uncleaned. Side-vented needle by

  1. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel (Dept. of Radiology, Medical Faculty, Univ. Duesseldorf, Duesseldorf (Germany)), email: Patric.Kroepil@med.uni-duesseldorf.de

    2011-10-15

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 +- 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 +- 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 +- 33 vs. n = 126 +- 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  2. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    International Nuclear Information System (INIS)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel

    2011-01-01

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 ± 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 ± 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 ± 33 vs. n = 126 ± 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  3. Ergonomics of disposable handles for minimally invasive surgery.

    Science.gov (United States)

    Büchel, D; Mårvik, R; Hallabrin, B; Matern, U

    2010-05-01

    The ergonomic deficiencies of currently available minimally invasive surgery (MIS) instrument handles have been addressed in many studies. In this study, a new ergonomic pistol handle concept, realized as a prototype, and two disposable ring handles were investigated according to ergonomic properties set by new European standards. In this study, 25 volunteers performed four practical tasks to evaluate the ergonomics of the handles used in standard operating procedures (e.g., measuring a suture and cutting to length, precise maneuvering and targeting, and dissection of a gallbladder). Moreover, 20 participants underwent electromyography (EMG) tests to measure the muscle strain they experienced while carrying out the basic functions (grasp, rotate, and maneuver) in the x, y, and z axes. The data measured included the number of errors, the time required for task completion, perception of pressure areas, and EMG data. The values for usability in the test were effectiveness, efficiency, and user satisfaction. Surveys relating to the subjective rating were completed after each task for each of the three handles tested. Each handle except the new prototype caused pressure areas and pain. Extreme differences in muscle strain could not be observed for any of the three handles. Experienced surgeons worked more quickly with the prototype when measuring and cutting a suture (approximately 20%) and during precise maneuvering and targeting (approximately 20%). On the other hand, they completed the dissection task faster with the handle manufactured by Ethicon. Fewer errors were made with the prototype in dissection of the gallbladder. In contrast to the handles available on the market, the prototype was always rated as positive by the volunteers in the subjective surveys. None of the handles could fulfil all of the requirements with top scores. Each handle had its advantages and disadvantages. In contrast to the ring handles, the volunteers could fulfil most of the tasks more

  4. A climate response function explaining most of the variation in the forest floor needle mass and the needle decomposition in pine forests across Europe

    DEFF Research Database (Denmark)

    Kurz-Besson, C.; Coûteaux, M.M.; Berg, Bjørn

    2006-01-01

    The forest floor needle mass and the decomposition rates of pine needle litter in a European climate transect were studied in order to estimate the impact of climate change on forest soil carbon sequestration. Eight pine forests preserved from fire were selected along a climatic latitudinal...... gradient from 40° to 60° N, from Spain and Portugal to Sweden. The forest floor (Oi and Oe layers) was sorted into five categories of increasing decomposition level according to morphological criteria. The needle mass loss in each category was determined using a linear mass density method. The needle...... and a recalcitrant one. NF was correlated with actual evapotranspiration (AET) whereas the decomposition parameters (decomposition rate of the decomposable fraction, first year mass loss, forest floor needle mass, age of the most-decomposed category) were related to a combined response function to climate (CRF...

  5. Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants

    Energy Technology Data Exchange (ETDEWEB)

    Manohar S. Sohal; J. Stephen Herring

    2008-07-01

    Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable

  6. [Meta-analysis of needle-knife treatment on cervical spondylosis].

    Science.gov (United States)

    Kan, Li-Li; Wang, Hai-Dong; Liu, An-Guo

    2013-11-01

    To assess the efficacy of cervical spondylosis by needle-knife treatment according to the correlated literature of RCT,to compare advantages of needle-knife treatment. Randomized Controlled Trials about needle-knife treatment of cervical spondylosis were indexed from Chinese HowNet (CNKI) and Wanfang (WF) from 2000 to 2012, then were analyzed the efficacy by Review Manager 5.1 software. A total of 13 RCT literatures and 1 419 patients were included. The methods of included studies were poor in quality evaluation because of large sample and multi-center RCT studies was lacked, randomization method was not accurate enough, diagnostic criteria and efficacy evaluation were various, only four studies described long-term efficacy, most of the literature didn't describe the adverse event and fall off,all studies did not use the blind method. The Meta analysis outcome showed overall efficiency of needle-knife therapy was better than acupuncture and traction. Needle-knife therapy compared with Acupuncture, the total RR = 0.19, 95% confidence interval was (0.15, 0.24), P knife therapy is higher;compared with traction therapy, although,needle-knife therapy has a high overall effectiveness, but because of the loss of total sample size, the outcome RCT researches to confirm.

  7. Dry needling in lateral epicondylitis: a prospective controlled study.

    Science.gov (United States)

    Uygur, Esat; Aktaş, Birol; Özkut, Afşar; Erinç, Samet; Yilmazoglu, Emime Gül

    2017-11-01

    Lateral epicondylitis (LE), a common disease, especially in middle age, causes decreased productivity and economic losses. The first-line treatment for LE is conservative and consists of topical and oral anti-inflammatory drugs, ice application, and brace use. If the first-line treatment fails, second-line treatment modalities, which are generally invasive, are offered. Second-line therapeutic regimens include saline, corticosteroid, or platelet-rich plasma injections. Dry needling is relatively new. We hypothesized that dry needling would be at least as effective as first-line treatment for LE. We compared the outcomes of first-line treatment and dry needling. The study allocated 110 patients into groups using online randomization software. After completing the Patient-rated Tennis Elbow Evaluation (PRTEE), patients in group I received dry needling, whereas those in group II received first-line treatment, consisting of ibuprofen 100 mg twice a day and a proximal forearm brace. The patients were evaluated after three weeks and six months. The study ultimately analyzed 92 patients. Although both treatment methods were effective at three weeks, dry needling was significantly more effective than the first-line treatment at six months. Because of the low complication rate, dry needling is a safe method, and it might be an effective treatment option for LE.

  8. King Injo's Disease and Burnt Needle Therapy

    Directory of Open Access Journals (Sweden)

    KIM In-Sook

    2004-12-01

    Full Text Available This paper investigates an interrelationship between burnt needle therapy(번침 and King Injo'sdisease. From 1633 (Year 11 in King Injo's reign to May 5, 1649 (Year 27 King in Injo's reign, right before his death, King Injo(인조 was treated with burnt needles by Yi Hyeongik(이형익, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have? Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon era, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease.  The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong(정명공주 derived from her mother, Queen Mother Inmok(인목대비. Moral justification for King Injo's coup was Gwanghaegun(광해군 or Prince Gwanghae's immoral conduct toward Queen Mother Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant

  9. Are needle-free injections a useful alternative for growth hormone therapy in children? Safety and pharmacokinetics of growth hormone delivered by a new needle-free injection device compared to a fine gauge needle.

    NARCIS (Netherlands)

    Dorr, H.G.; Zabransky, S.; Keller, E.; Otten, B.J.; Partsch, C.J.; Nyman, L.; Gillespie, B.K.; Lester, N.R.; Wilson, A.M.; Hyren, C.; Kuijck, M.A. van; Schuld, P.; Schoenfeld, S.L.

    2003-01-01

    The clinical safety, use and pharmacokinetics of a new needle-free device for delivery of growth hormone (GH) were compared with those of conventional needle injection devices. In an open-label, randomized, 4-period crossover study, 18 healthy adults received single subcutaneous injections of

  10. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  11. Thyroid Fine-Needle Aspiration Cytology Practice in Korea

    Directory of Open Access Journals (Sweden)

    Yoon Jin Cha

    2017-11-01

    Full Text Available We reviewed the current status of thyroid fine-needle aspiration cytology (FNAC in Korea. Thyroid aspiration biopsy was first introduced in Korea in 1977. Currently, radiologists aspirate the thyroid nodule under the guidance of ultrasonography, and cytologic interpretation is only legally approved when a cytopathologist makes the diagnosis. In 2008, eight thyroid-related societies came together to form the Korean Thyroid Association. The Korean Society for Cytopathology and the endocrine pathology study group of the Korean Society for Pathologists have been updating the cytologic diagnostic guidelines. The Bethesda System for Reporting Thyroid Cytopathology was first introduced in 2009, and has been used by up to 94% of institutions by 2016. The average diagnosis rates are as follows for each category: I (12.4%, II (57.9%, III (10.4%, IV (2.9%, V (3.7%, and VI (12.7%. The malignancy rates in surgical cases are as follows for each category: I (28.7%, II (27.8%, III (50.6%, IV (52.3%, V (90.7%, and VI (100.0%. Liquid-based cytology has been used since 2010, and it was utilized by 68% of institutions in 2016. The categorization of thyroid lesions into “atypia of undetermined significance” or “follicular lesion of undetermined significance” is necessary to draw consensus in our society. Immunocytochemistry for galectin-3 and BRAF is used. Additionally, a molecular test for BRAF in thyroid FNACs is actively used. Core biopsies were performed in only 44% of institutions. Even the institutions that perform core biopsies only perform them for less than 3% of all FNACs. However, only 5% of institutions performed core biopsies up to three times more than FNAC.

  12. Fine-needle versus core-needle biopsy – which one to choose in preoperative assessment of focal lesions in the breasts? Literature review

    Directory of Open Access Journals (Sweden)

    Ewa Łukasiewicz

    2017-12-01

    Full Text Available Aim: The aim of the study was to review two techniques that can be used to verify focal lesions in the breasts: fine-needle aspiration biopsy and core-needle biopsy. Material and methods: Fifty-five articles (original papers and reviews, half of them published within the past 5 years, were included in the analysis. The authors also took their own experience into account. Results: Pre-operative assessment of focal lesions in the breasts is crucial in the planning of further therapeutic management. The role of fine-needle aspiration biopsy has been reduced lately due to its low sensitivity and specificity as well as a high rate of non-diagnostic, suspicious and false negative results. This method does not enable one to differentiate between in situ and invasive disease. Currently, fine-needle biopsy is recommended for cystic lesions, suspected of being recurrences in the chest wall, and lymph node metastases. Core-needle biopsy is the basic diagnostic method of breast lesions. According to the recommendations of the Polish Ultrasound Society and American College of Radiology, BIRADS 4 and 5 lesions should be evaluated histopathologically. Core-needle biopsy makes it possible to establish a final diagnosis more frequently than fine-needle biopsy, both in the case of benign and malignant lesions. It delivers more information about the nature of a tumor (mutation of HER-2, estrogen and progesterone receptors and Ki-67 index. Its limitations include: underestimation of invasion and failure to recognize the components of ductal carcinoma in situ in papillary and atypical lesions. Single fine-needle aspiration biopsy is inexpensive, but when considering the cost of further diagnosis due to non-diagnostic, suspicious and atypical results, this method generates high additional costs. Conclusions: Microscopic verification of focal breast lesions is crucial for further therapeutic decisions. It has been proven that histopathological verification is more

  13. Modified microdissection electrocautery needle

    OpenAIRE

    Singh, Virendra; Kumar, Pramod

    2014-01-01

    Electrocautery is routinely used in surgical procedures. The commercially available microdissection electrocautery needles are costly. To overcome this disadvantage, we have modified monopolar electrocautery tip to function as well as commercially available systems.

  14. Measurement of tritium in tissue free water of pine needles

    International Nuclear Information System (INIS)

    Zheng Xiaomin; Wu Zongmei

    1993-01-01

    Tissue Free Water (TFW) of pine needles is separated out through azeotropic distillation of pine needles and toluene. Recovery ratio of TFW is 90%. Tritium activity in the needles is 1.8 Bq/L(H 2 O), which is of the same level with tritiated water vapour (HTO) in atmosphere during the corresponding period

  15. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  16. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    International Nuclear Information System (INIS)

    Thompson, S.A.; Fung, A.Y.C.; Zaider, M.

    2002-01-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  17. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, S.A. [Department of Medical Physics, North Shore-Long Island Jewish Health System, Manhassett, NY (United States); Fung, A.Y.C.; Zaider, M. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2002-08-21

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  18. Combating wear in bulk solids handling plants

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    A total of five papers presented at a seminar on problems of wear caused by abrasive effects of materials in bulk handling. Topics of papers cover the designer viewpoint, practical experience from the steel, coal, cement and quarry industries to create an awareness of possible solutions.

  19. Reproductive handle of the herd of cattle of double purpose

    International Nuclear Information System (INIS)

    Castro Hernandez, A.

    1988-01-01

    The influence of the environmental factors is analyzed, in the reproductive efficiency of herd cattle of double purpose. The reproductive behavior begins with the gestation of the heifers. Under the conditions of the Colombian tropic these they reach the weight required for the reproduction to an age but late that in the temperate areas. Once the first childbirth, the cow takes place it enters in exhaustion that makes that this animal is the but difficult to reproduce after the childbirth, that which demands special cares of handling and feeding. The interval among the childbirth to evaluate the reproductive efficiency. Environmental factors that influence significantly. The use of the practice simple of handling, health, selection and feeding produces significant increments in the fertility of the herd of cattle of double purpose. One practices of effective handling in the improvement of the reproductive behavior of the cows of double purpose it is the restricted nursing

  20. The Hydrodynamics of Needle-Free Intradermal Jet Injection

    Science.gov (United States)

    Simmons, Jonathan; Marston, Jeremy; Fisher, Paul; Broderick, Kate

    2017-11-01

    Needle-free methods of drug delivery circumvent the drawbacks associated with the use of hypodermic needles such as needle-stick injuries, needle-phobia, cross contamination and disposal. Furthermore, pioneering DNA-based vaccines that aim to treat cancer and fight infectious diseases, such as HIV, Ebola and Zika, require precise deposition into the skin to target the immune response producing cells found only in the epidermis and dermis. Intradermal (ID) delivery can be achieved using a needle and the Mantoux technique but this requires a highly skilled technician and so extensive use of DNA vaccines calls for an alternative method of delivery. One option is jet injection which has been employed in mass vaccination programs for intramuscular or subcutaneous delivery and is used by some diabetic patients to inject insulin. In this talk I will present results from our ongoing ex-vivo experimental study into ID jet injection. Ultra-high-speed imaging is used to visualize the process of the jet exiting the nozzle and striking excised skin. A skin bleb grows as liquid is deposited within the skin. I will discuss how the control parameters, such as the rheological profile of the liquid and the stand-off distance, influence the volume of liquid successfully delivered intradermally.

  1. Handling a challenging context: experiences of facilitating evidence-based elderly care.

    Science.gov (United States)

    Nygårdh, Annette; Ahlström, Gerd; Wann-Hansson, Christine

    2016-03-01

    To explore improvement facilitators' experiences of handling their commission to implement evidence-based practice in elderly care for frail older persons. Improvement facilitators were put in place across Sweden in a time-limited project by the government, with one part of the project being to evaluate the model before establishing this facilitation of evidence-based practice in elderly care. Two focus groups were interviewed twice. Each group comprised three respondents. The interviews were analysed using qualitative content analysis. A main theme, 'Moving forward by adjusting to the circumstances', described how the improvement facilitators handle their commitment. Five subthemes emerged: identifying barriers, keeping focus, maintaining motivation, building bridges and finding balance. The improvement facilitators' commitment is ambiguous because of unclear leadership of, and responsibility for the national investment. They have to handle leaders' different approaches and justify the need for evidence-based practice. The improvement facilitators did not reflect on the impact of programme adaptations on evidence-based practice. The findings emphasise the need for collaboration between the improvement facilitator and the nurse manager. To fully implement evidence-based practice, negotiations with current practitioners for adaptation to local conditions are necessary. Furthermore, the value of improving organisational performance needs to be rigorously communicated throughout the organisation. © 2015 The Authors. Journal of Nursing Management Published by John Wiley & Sons Ltd.

  2. Single-incision laparoscopic cholecystectomy with needle graspers.

    Science.gov (United States)

    Sumiyoshi, Kinjiro; Sato, Norihiro; Akagawa, Shin; Hirano, Tatsuya; Koikawa, Kazuhiro; Horioka, Kohei; Ozono, Keigo; Fujiwara, Kenji; Tanaka, Masao; Sada, Masayuki

    2012-01-01

    Single-incision laparoscopic cholecystectomy (SILC) is a promising alternative to standard multi-incision laparoscopic cholecystectomy (LC). However, generalization of SILC is still hampered by technical difficulties mainly associated with the lack of trocars used for retraction of the gallbladder. We therefore developed a modified method of SILC with the use of needle graspers (SILC-N) for optimal retraction and exposure. In addition to two trocars inserted through a single transumbilical incision, two needle ports were placed on the right subcostal and lateral abdominal wall, through which needle graspers were used for retraction of the gallbladder. Since December, 2009, 12 patients with symptomatic cholelithiasis were treated by SILC-N. SILC-N was successfully performed in all but one patient requiring a conversion to the 4-port LC with a mean operative time of 71.5 (48-107) minutes. None of the patients experienced intraoperative or postoperative complications. The transumbilical incision and pinholes for needle graspers were almost invisible on discharge. Our preliminary results suggest that SILC-N is a simple, safe and feasible technique of cholecystectomy offering similar postoperative recovery and better cosmetic outcome as compared to conventional LC.

  3. Needle-shaped and platelet growth of borax crystals

    International Nuclear Information System (INIS)

    Takoo, R.K.; Patel, B.R.; Joshi, M.S.

    1983-01-01

    Needle-shaped and platelet growth of borax crystals from solutions is reported. Results of microtopographical studies on both the varieties are discussed. It is suggested that a slow rate of evaporation favours needle growth and a faster rate is conducive to the growth of platelets. (author)

  4. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  5. Thermal formation of mesoporous single-crystal Co3O4 nano-needles and their lithium storage properties

    KAUST Repository

    Lou, Xiong Wen; Deng, Da; Lee, Jim Yang; Archer, Lynden A.

    2008-01-01

    In this work, we report the simple solid-state formation of mesoporous Co3O4 nano-needles with a 3D single-crystalline framework. The synthesis is based on controlled thermal oxidative decomposition and re-crystallization of precursor β-Co(OH)2 nano-needles. Importantly, after thermal treatment, the needle-like morphology can be completely preserved, despite the fact that there is a large volume contraction accompanying the process: β-Co(OH)2 → Co3O 4. Because of the intrinsic crystal contraction, a highly mesoporous structure with high specific surface area has been simultaneously created. The textual properties can be easily tailored by varying the annealing temperature between 200-400 °C. Interestingly, thermal re-crystallization at higher temperatures leads to the formation of a perfect 3D single-crystalline framework. Thus derived mesoporous Co3O4 nano-needles serve as a good model system for the study of lithium storage properties. The optimized sample manifests very low initial irreversible loss (21%), ultrahigh capacity, and excellent cycling performance. For example, a reversible capacity of 1079 mA h g-1 can be maintained after 50 cycles. The superior electrochemical performance and ease of synthesis may suggest their practical use in lithium-ion batteries. © The Royal Society of Chemistry 2008.

  6. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  7. Determination of rare earth elements in the biological reference materials Pine Needles and Spruce Needles by neutron activation analysis

    International Nuclear Information System (INIS)

    Machado, C.N.; Maria, S.P.; Saiki, M.; Figueiredo, A.M.G.

    1998-01-01

    Instrumental neutron activation analysis was applied to determine La, Ce, Nd, Sm, Eu, Tb, Yb, Lu and Sc in two biological reference materials: NIST 1575 Pine Needles and BCR-CRM 101 Spruce Needles. The purpose was to contribute to the reference data for these two reference materials. The results were obtained with a good precision (relative standard deviations less than 15%). For the Pine Needles reference material there are already some proposed values and our results showed, in general, a good agreement with the data published. The contribution of uranium fission products to La, Ce, Nd and Sm was evaluated and considered in the determination of these elements. Interferences in the determination of rare earth elements in biological materials are also discussed. (author)

  8. Novel design of honeybee-inspired needles for percutaneous procedure.

    Science.gov (United States)

    Sahlabadi, Mohammad; Hutapea, Parsaoran

    2018-04-18

    The focus of this paper is to present new designs of innovative bioinspired needles to be used during percutaneous procedures. Insect stingers have been known to easily penetrate soft tissues. Bioinspired needles mimicking the barbs in a honeybee stinger were developed for a smaller insertion force, which can provide a less invasive procedure. Decreasing the insertion force will decrease the tissue deformation, which is essential for more accurate targeting. In this study, some design parameters, in particular, barb shape and geometry (i.e. front angle, back angle, and height) were defined, and their effects on the insertion force were investigated. Three-dimensional printing technology was used to manufacture bioinspired needles. A specially-designed insertion test setup using tissue mimicking polyvinyl chloride (PVC) gels was developed to measure the insertion and extraction forces. The barb design parameters were then experimentally modified through detailed experimental procedures to further reduce the insertion force. Different scales of the barbed needles were designed and used to explore the size-scale effect on the insertion force. To further investigate the efficacy of the proposed needle design in real surgeries, preliminary ex vivo insertion tests into bovine liver tissue were performed. Our results show that the insertion force of the needles in different scales decreased by 21-35% in PVC gel insertion tests, and by 46% in bovine liver tissue insertion tests.

  9. Handling of Solid Residues

    International Nuclear Information System (INIS)

    Medina Bermudez, Clara Ines

    1999-01-01

    The topic of solid residues is specifically of great interest and concern for the authorities, institutions and community that identify in them a true threat against the human health and the atmosphere in the related with the aesthetic deterioration of the urban centers and of the natural landscape; in the proliferation of vectorial transmitters of illnesses and the effect on the biodiversity. Inside the wide spectrum of topics that they keep relationship with the environmental protection, the inadequate handling of solid residues and residues dangerous squatter an important line in the definition of political and practical environmentally sustainable. The industrial development and the population's growth have originated a continuous increase in the production of solid residues; of equal it forms, their composition day after day is more heterogeneous. The base for the good handling includes the appropriate intervention of the different stages of an integral administration of residues, which include the separation in the source, the gathering, the handling, the use, treatment, final disposition and the institutional organization of the administration. The topic of the dangerous residues generates more expectation. These residues understand from those of pathogen type that are generated in the establishments of health that of hospital attention, until those of combustible, inflammable type, explosive, radio-active, volatile, corrosive, reagent or toxic, associated to numerous industrial processes, common in our countries in development

  10. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  11. Fine needle diagnosis in lumbar osteomyelitis

    International Nuclear Information System (INIS)

    Joshi, K.B.; Brinker, R.A.

    1983-01-01

    Lumbar vertebral body and disk infection, presenting as low back pain, is a relatively uncommon disease but is seen more often in drug addicts. Radiographs show typical changes of infection of the lumbar vertebrae and adjacent disc. Under local anesthesia a fine needle is placed, saline injected, and aspirated. The entire needle-syringe unit is submitted to the bacteriology department. Pseudomonas infection is usually found. This method of diagnosis is simple, cost effective, well accepted by the patients, and can be done on outpatients. (orig.)

  12. Kalman filter-based EM-optical sensor fusion for needle deflection estimation.

    Science.gov (United States)

    Jiang, Baichuan; Gao, Wenpeng; Kacher, Daniel; Nevo, Erez; Fetics, Barry; Lee, Thomas C; Jayender, Jagadeesan

    2018-04-01

    In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.

  13. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  14. Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy

    International Nuclear Information System (INIS)

    Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    An algorithm was developed in order to segment and track brachytherapy needles inserted along oblique trajectories. Three-dimensional (3D) transrectal ultrasound (TRUS) images of the rigid rod simulating the needle inserted into the tissue-mimicking agar and chicken breast phantoms were obtained to test the accuracy of the algorithm under ideal conditions. Because the robot possesses high positioning and angulation accuracies, we used the robot as a ''gold standard,'' and compared the results of algorithm segmentation to the values measured by the robot. Our testing results showed that the accuracy of the needle segmentation algorithm depends on the needle insertion distance into the 3D TRUS image and the angulations with respect to the TRUS transducer, e.g., at a 10 deg. insertion anglulation in agar phantoms, the error of the algorithm in determining the needle tip position was less than 1 mm when the insertion distance was greater than 15 mm. Near real-time needle tracking was achieved by scanning a small volume containing the needle. Our tests also showed that, the segmentation time was less than 60 ms, and the scanning time was less than 1.2 s, when the insertion distance into the 3D TRUS image was less than 55 mm. In our needle tracking tests in chicken breast phantoms, the errors in determining the needle orientation were less than 2 deg. in robot yaw and 0.7 deg. in robot pitch orientations, for up to 20 deg. needle insertion angles with the TRUS transducer in the horizontal plane when the needle insertion distance was greater than 15 mm

  15. Transcription through the eye of a needle: daily and annual cyclic gene expression variation in Douglas-fir needles

    OpenAIRE

    Cronn, Richard; Dolan, Peter C.; Jogdeo, Sanjuro; Wegrzyn, Jill L.; Neale, David B.; St. Clair, J. Bradley; Denver, Dee R.

    2017-01-01

    Background Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal cycles and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii) n...

  16. Fuel handling machine and auxiliary systems for a fuel handling cell

    International Nuclear Information System (INIS)

    Suikki, M.

    2013-10-01

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  17. Fuel handling machine and auxiliary systems for a fuel handling cell

    Energy Technology Data Exchange (ETDEWEB)

    Suikki, M. [Optimik Oy, Turku (Finland)

    2013-10-15

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  18. Effect of needle puncture and electro-acupuncture on mucociliary clearance in anesthetized quails

    Directory of Open Access Journals (Sweden)

    Wang Tianshan

    2006-02-01

    Full Text Available Abstract Background Acupuncture therapy for obstructive respiratory diseases has been effectively used in clinical practice and the acupuncture points or acupoints of Zhongfu and Tiantu are commonly-used acupoints to treat patients with the diseases. Since the impaired mucociliary clearance is among the most important features of airway inflammation in most obstructive respiratory diseases, the effect of needle puncture and electro-acupuncture at the specific acupoints on tracheal mucociliary clearance was investigated in anesthetized quails. Methods Mucociliary transport velocity on tracheal mucosa was measured through observing the optimal pathway, and fucose and protein contents in tracheal lavages were determined with biochemical methods. In the therapeutic group, needle puncture or electro-acupuncture stimulation to the acupoints was applied without or with constant current output in 2 mA and at frequency of 100 Hz for 60 minutes. In the sham group, electro-acupuncture stimulation to Liangmen was applied. Results Our present experiments demonstrated that the electro-acupuncture stimulation to Zhongfu and Tiantu significantly increased tracheal mucociliary transport velocity and decreased the content of protein in the tracheal lavage, compared with the control group. Moreover, either needle puncture or electro-acupuncture stimulation to Zhongfu and Tiantu significantly reverted the human neutrophil elastase-induced decrease in tracheal mucociliary transport velocity and human neutrophil elastase -induced increase in the contents of fucose and protein in the tracheal lavage, compared with the control group. Conclusion These results suggest that either needle puncture or electro-acupuncture stimulation to the effective acupoints significantly improves both airway mucociliary clearance and the airway surface liquid and that the improvements maybe ascribed to both the special function of the points and the substantial stimulation of electricity.

  19. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  1. Improved radionuclide bone imaging agent injection needle withdrawal method can improve image quality

    International Nuclear Information System (INIS)

    Qin Yongmei; Wang Laihao; Zhao Lihua; Guo Xiaogang; Kong Qingfeng

    2009-01-01

    Objective: To investigate the improvement of radionuclide bone imaging agent injection needle withdrawal method on whole body bone scan image quality. Methods: Elbow vein injection syringe needle directly into the bone imaging agent in the routine group of 117 cases, with a cotton swab needle injection method for the rapid pull out the needle puncture point pressing, pressing moment. Improvement of 117 cases of needle injection method to put two needles into the skin swabs and blood vessels, pull out the needle while pressing two or more entry point 5min. After 2 hours underwent whole body bone SPECT imaging plane. Results: The conventional group at the injection site imaging agents uptake rate was 16.24%, improved group was 2.56%. Conclusion: The modified bone imaging agent injection needle withdrawal method, injection-site imaging agent uptake were significantly decreased whole body bone imaging can improve image quality. (authors)

  2. Needle-free influenza vaccination

    NARCIS (Netherlands)

    Amorij, Jean-Pierre; Hinrichs, Wouter L.J.; Frijlink, Henderik W.; Wilschut, Jan C.; Huckriede, Anke

    2010-01-01

    Vaccination is the cornerstone of influenza control in epidemic and pandemic situations. Influenza vaccines are typically given by intramuscular injection. However, needle-free vaccinations could offer several distinct advantages over intramuscular injections: they are pain-free, easier to

  3. Tumour seeding following percutaneous needle biopsy: The real story

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, E.G. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Baxter, G., E-mail: grant.baxter@ggc.scot.nhs.uk [Department of Radiology, Western Infirmary, Glasgow (United Kingdom)

    2011-11-15

    The demand for percutaneous needle biopsy is greater than ever before and with the majority of procedures requiring imaging guidance, radiologists have an increasingly important role in the diagnostic work-up of patients with suspected malignancy. All invasive procedures incur potential risks; therefore, clinicians should be aware of the most frequently encountered complications and have a realistic idea of their likelihood. Tumour seeding, whereby malignant cells are deposited along the tract of a biopsy needle, can have disastrous consequences particularly in patients who are organ transplant candidates or in those who would otherwise expect good long-term survival. Fortunately, tumour seeding is a rare occurrence, yet the issue invariably receives a high profile and is often regarded as a major contraindication to certain biopsy procedures. Although its existence is in no doubt, realistic insight into its likelihood across the spectrum of biopsy procedures and multiple anatomical sites is required to permit accurate patient counselling and risk stratification. This review provides a comprehensive overview of tumour seeding and examines the likelihood of this much feared complication across the range of commonly performed diagnostic biopsy procedures. Conclusions have been derived from an extensive analysis of the published literature, and a number of key recommendations should assist practitioners in their everyday practice.

  4. Different ways to handle topography in practical geoid determination

    DEFF Research Database (Denmark)

    Dahl, O.C.; Forsberg, René

    1999-01-01

    In this paper two different methods of how to handle topography in geoid determination is investigated. First method employs the Residual Terrain Model (RTM) remove-restore technique and yields the quasigeoid, whereas the second method is the classical Helmert condensation method, yielding...... the topography was represented by either a detailed (100 m) or a coarse (1000 m) digital terrain model. The inclusion of bathymetry in the terrain model was also investigated. Even if two different methods were used, they produced almost identical results at the 5 cm level in the mountains, but small systematic...

  5. Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

    Energy Technology Data Exchange (ETDEWEB)

    Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego; Angelino, Valeria; Priola, Adriano M. [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Novello, Silvia [University of Torino, Department of Oncology, San Luigi Gonzaga Hospital (Italy); Barba, Matteo [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Gatti, Gaia; Righi, Luisella [University of Torino, Department of Pathology, San Luigi Gonzaga Hospital (Italy)

    2017-06-15

    PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

  6. A variable stiffness mechanism for steerable percutaneous instruments: integration in a needle.

    Science.gov (United States)

    De Falco, Iris; Culmone, Costanza; Menciassi, Arianna; Dankelman, Jenny; van den Dobbelsteen, John J

    2018-06-04

    Needles are advanced tools commonly used in minimally invasive medical procedures. The accurate manoeuvrability of flexible needles through soft tissues is strongly determined by variations in tissue stiffness, which affects the needle-tissue interaction and thus causes needle deflection. This work presents a variable stiffness mechanism for percutaneous needles capable of compensating for variations in tissue stiffness and undesirable trajectory changes. It is composed of compliant segments and rigid plates alternately connected in series and longitudinally crossed by four cables. The tensioning of the cables allows the omnidirectional steering of the tip and the stiffness tuning of the needle. The mechanism was tested separately under different working conditions, demonstrating a capability to exert up to 3.6 N. Afterwards, the mechanism was integrated into a needle, and the overall device was tested in gelatine phantoms simulating the stiffness of biological tissues. The needle demonstrated the capability to vary deflection (from 11.6 to 4.4 mm) and adapt to the inhomogeneity of the phantoms (from 21 to 80 kPa) depending on the activation of the variable stiffness mechanism. Graphical abstract ᅟ.

  7. A study on applying Ra needle interstitial brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yoshida, Shunichi; Komiya, Yoshiaki; Uchida, Ikuhiro; Tashiro, Kazuyoshi

    1999-01-01

    To investigate applicability of Ra needle interstitial brachytherapy, 93 cases of oral squamous carcinoma were examined. The patients underwent Ra needle interstitial brachytherapy as thorough therapy in our hospital. The criteria of applying Ra needle interstitial brachytherapy was diameter of within 5 cm and depth within 2 cm of tumor size. Ra needle interstitial brachytherapy was applied to 82 cases of tongue, 10 cases of oral floor and one case of lower lip carcinomas. The local control rate was 92.5%, and secondary neck metastasis was 32.3% in all cases applied Ra needle interstitial brachytherapy. The results were not bad compared with surgical treatment. However, the 5-year cumulative survival rate was 64.9%, which was not good enough at the result to obtain a good local control rate and secondary neck metastasis rate. The result was relative to low treatment result of local recurrence cases with Ra needle interstitial brachytherapy. To improve the result, it is important to distinguish local recurrence from radioinduced ulcer, and to start early secondary treatment. The cases in which cervical lymph node metastasis was found as the first examination underwent neck dessection after Ra needle interstitial brachytherapy. The 5-year cumulative survival rate was 83.3% in N1 cases and 40.6% in N2 cases, and the result of N2 cases was poorer than N1 cases with a significant difference. The results indicate that a needle having a diameter of within 5 cm, depth of within 2 cm and less than N1 can be applied during Ra needle interstitial brachytherapy for complete cure of cancer. (author)

  8. SU-D-213AB-06: Surface Texture and Insertion Speed Effect on Needle Friction.

    Science.gov (United States)

    Abdullah, A; Golecki, C; Barnett, A; Moore, J

    2012-06-01

    High frictional forces between the needle surface and tissue cause tissue deflection which hinders accurate needle placement for procedures such as brachytherapy and needle biopsy. Accurate needle placement isimportant to maximize procedure efficacy. This work investigates how needle surface roughness and insertion speed affect the frictional forcebetween a needle and tissue. A friction experiment was conducted to measure the force of friction between bovine liver and three 11 gauge needles having Ra surface roughness of 3.43, 1.33, and 0.2 μm. Each of the three needles were mounted on a linear slide and were advanced and retracted through bovine liver at speeds of 50, 100, 150, and 200 mm/s for a total of 12 trials. In each trial the needle was advanced and retracted in 10 cycles producing a steady state insertion force and a steady state retraction force for each cycle. A force sensor connecting the needle to the linear slide recorded the resistance force of the needle sliding through the liver. The liver was mounted in a box with a pneumatic cylinder which compressed the liver sample by 11.65 kPa. The roughest needle (Ra = 3.43 μm) on average produced 68, 73, 74, and 73% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200mm/s, respectively. The second roughest needle (Ra = 1.33 μm) on average produced 25, 45, 60 and 64% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200 mm/s, respectively. Rougher needle surface texture and higher insertion speed reduced frictional forces between the tissue and the needle. Future studies will examine how frictional forces can be modeled and predicted given surface texture and insertion speed. © 2012 American Association of Physicists in Medicine.

  9. Students as effective harm reductionists and needle exchange organizers.

    Science.gov (United States)

    Barbour, Kyle; McQuade, Miriam; Brown, Brandon

    2017-03-17

    Needle exchange programs are safe, highly effective programs for promoting health among people who inject drugs. However, they remain poorly funded, and often illegal, in many places worldwide due to fear and stigma surrounding drug use. Continued advocacy, education, and implementation of new needle exchanges are thus essential to improve public health and reduce structural inequality. We argue that students, and especially professional and graduate students, have the potential to play an important role in advancing harm reduction. Students benefit from the respect given to the professions they are training to enter, which gives them leverage to navigate the political hurdles often faced by needle exchange organizers, especially in areas that presently lack services. In addition, due to their relative simplicity, needle exchanges do not require much of the licensing, clinical knowledge, and infrastructure associated with more traditional student programs, such as student-run free medical clinics. Students are capable of learning harm reduction cultural approaches and techniques if they remain humble, open-minded, and seek the help of the harm reduction community. Consequently, students can generate tremendous benefits to their community without performing beyond their appropriate clinical limitations. Students benefit from organizing needle exchanges by gaining applied experience in advocacy, organization-building, and political finesse. Working in a needle exchange significantly helps erode stigma against multiple marginalized populations. Students in health-related professions additionally learn clinically-relevant knowledge that is often lacking from their formal training, such as an understanding of structural violence and inequality, root causes of substance use, client-centered approaches to health services, and interacting with clients as peers, rather than through the standard hierarchical medical interaction. We therefore encourage students to learn about

  10. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.

    Science.gov (United States)

    Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John

    2018-01-01

    In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.

  11. Detection of Membrane Puncture with Haptic Feedback using a Tip-Force Sensing Needle.

    Science.gov (United States)

    Elayaperumal, Santhi; Bae, Jung Hwa; Daniel, Bruce L; Cutkosky, Mark R

    2014-09-01

    This paper presents calibration and user test results of a 3-D tip-force sensing needle with haptic feedback. The needle is a modified MRI-compatible biopsy needle with embedded fiber Bragg grating (FBG) sensors for strain detection. After calibration, the needle is interrogated at 2 kHz, and dynamic forces are displayed remotely with a voice coil actuator. The needle is tested in a single-axis master/slave system, with the voice coil haptic display at the master, and the needle at the slave end. Tissue phantoms with embedded membranes were used to determine the ability of the tip-force sensors to provide real-time haptic feedback as compared to external sensors at the needle base during needle insertion via the master/slave system. Subjects were able to determine the position of the embedded membranes with significantly better accuracy using FBG tip feedback than with base feedback using a commercial force/torque sensor (p = 0.045) or with no added haptic feedback (p = 0.0024).

  12. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  13. In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun; Clark, Douglas; Sherman, Jason; Fuller, Dave; Messing, Edward; Rubens, Deborah; Strang, John; Brasacchio, Ralph; Liao, Lydia; Ng, W.-S.; Yu Yan

    2006-01-01

    In this paper, we present needle insertion forces and motion trajectories measured during actual brachytherapy needle insertion while implanting radioactive seeds in the prostate glands of 20 different patients. The needle motion was captured using ultrasound images and a 6 degree-of-freedom electromagnetic-based position sensor. Needle velocity was computed from the position information and the corresponding time stamps. From in vivo data we found the maximum needle insertion forces to be about 15.6 and 8.9 N for 17 gauge (1.47 mm) and 18 gauge (1.27 mm) needles, respectively. Part of this difference in insertion forces is due to the needle size difference (17G and 18G) and the other part is due to the difference in tissue properties that are specific to the individual patient. Some transverse forces were observed, which are attributed to several factors such as tissue heterogeneity, organ movement, human factors in surgery, and the interaction between the template and the needle. However, theses insertion forces are significantly responsible for needle deviation from the desired trajectory and target movement. Therefore, a proper selection of needle and modulated velocity (translational and rotational) may reduce the tissue deformation and target movement by reducing insertion forces and thereby improve the seed delivery accuracy. The knowledge gleaned from this study promises to be useful for not only designing mechanical/robotic systems but also developing a predictive deformation model of the prostate and real-time adaptive controlling of the needle

  14. [Treatment of Persistent Somatoform Pain Disorder by Floating Needle Therapy and Duloxetine].

    Science.gov (United States)

    Ren, Wan-wen; Zhou, Zhi-ying; Xu, Mi-mi; Long, Sen; Tang, Guang-zheng; Mao, Hong-jing; Chen, Shu-lin

    2016-02-01

    To evaluate clinical effect and safety of floating needle therapy and duloxetine in treating patients with persistent somatoform pain disorder (PSPD). Totally 108 PSPD patients were randomly assigned to the floating needle treatment group, the duloxetine treatment group, and the placebo treatment group, 36 in each group. Patients in the floating needle treatment group received floating needle therapy and placebo. Those in the duloxetine treatment group received duloxetine and simulated floating needle therapy. Those in the placebo treatment group received the placebo and simulated floating needle therapy. All treatment lasted for six weeks. Efficacy and adverse reactions were evaluated using Simple McGill pain scale (SF-MPQ) and Treatment Emergent Symptom Scale (TESS) before treatment and immediately after treatment, as well as at the end of 1st, 2nd, 4th, and 6th week of treatment, respectively. Hamilton Depression Scale (HAMD, 17 items), Hamilton Anxiety Scale (HAMA) were assessed before treatment and at the end of 1st, 2nd, 4th, and 6th week of treatment, respectively. Patients in the floating needle treatment group and the duloxetine treatment group with the total reducing score rate of SF-MPQ in Pain Rating index (PRI) ≥ 50% after 6 weeks' treatment were involved in the follow-up study. (1) Compared with the same group before treatment, SF-MPQ score, HAMD score and HAMA total scores all decreased in all the three groups at the end of 1st, 2nd, 4th, and 6th week of treatment (P floating needle treatment group (P floating needle treatment group significantly decreased after 1, 2, 4, and 6 weeks of treatment (P floating needle treatment group, 17 (50.0%) in the duloxetine treatment group, and 7 (21.2%) in the placebo treatment group. Compared with the placebo treatment group, the incidence of adverse reaction increased in the duloxetine treatment group (χ² = 6.04, P floating needle treatment group (χ² = 14.9, P floating needle treatment group and 17

  15. NEEDLE KNIFE SPHINCTEROTOMY - THE CHRIS HANI BARAGWANATH ACADEMIC HOSPITAL EXPERIENCE.

    Science.gov (United States)

    Thomson, J T; Smith, M D; Omoshoro-Jones, J A O; Devar, J D; Khan, Z K; Jugmohan, B J

    2017-06-01

    Deep biliary cannulation is essential in performing a therapeutic ERCP. Cannulation can be enhanced through the utilization of a pre-cut by means of a needle knife sphincterotomy. Retrospective analysis of the Chris Hani Baragwanath Academic Hospital's ERCP database was performed. All ERCPs performed with the aid of a needle knife were identified and analysed for successful and unsuccessful deep biliary cannulation. 2830 ERCPs were performed during the study period. 369 (13%) required needle knife sphincterotomies and successful deep biliary cannulation was achieved in 229 (62%) of these patients. Repeat ERCPs were performed on 125 (34%) patients. 61 (49%) of the repeat ERCPs were performed because of previously failed cannulation. 34 (56%) of these repeat ERCPs resulted in successful deep biliary cannulation at re-attempt. 99% of successful cannulations at repeat ERCP had had a needle knife sphincterotomy at the first ERCP. Needle knife sphincterotomy improves deep biliary cannulation at initial ERCP and subsequent ERCPs with low incidences of complications.

  16. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  17. Transcription Through The Eye Of A Needle: Daily And Annual Cycles Of Gene Expression Variation In Douglas-Fir Needles

    OpenAIRE

    Dolan, Peter; Cronn, Richard; Denver, Dee; Clair, J.; Neale, David; Wegrzyn, Jill; Jogdeo, Sanjuro

    2017-01-01

    Background: Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal rhythms and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii)...

  18. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho

    2017-01-30

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  19. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho; Perez, Jose E.; Ivanov, Yurii; Bertoncini, Andrea; Liberale, Carlo; Kosel, Jü rgen

    2017-01-01

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  20. [Practical advices in choosing local anesthesia tools in dentistry. Management of carpule's quality in local anesthesia in dentistry].

    Science.gov (United States)

    Kuzin, A V

    2014-01-01

    The equipment for local anesthesia is described in this article. Practical recommendations for the selection of the injection needle length, size, bevel type is given. Using dental needle for local anesthesia should be guided by the "one injection - one needle" rule, as a needle tends to deform by even the slightest contact with jawbone. Some of the shortcomings of carpule quality may be detected before use: signs of cup corrosion, the presence of sediment, air bubbles, rubber plunger disposition. In the case of such defects being identified all the package should not be used. The use of such carpule in clinical practice is unsafe.

  1. [Closed needle-biopsy in the diagnosis of neoplasms].

    Science.gov (United States)

    Sforza, M; Perelli Ercolini, M; Beani, G

    1979-04-01

    The AA. demonstrate with this communication the validity of the needle biopsie for the diagnosis of neoplasms. They had used it for the breast, thyroid, flg and some other superficial tumefactions. In the mass-screening for the feminine neoplasms the clinical examination and the needle biopsy are very good method for a careful diagnosis.

  2. Options for reducing HIV transmission related to the dead space in needles and syringes.

    Science.gov (United States)

    Zule, William A; Pande, Poonam G; Otiashvili, David; Bobashev, Georgiy V; Friedman, Samuel R; Gyarmathy, V Anna; Des Jarlais, Don C

    2018-01-15

    When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would remain in different combinations following injection and rinsing. Syringe barrel capacities ranged from 0.5 to 20 mL. Needles ranged in length from 8 to 38 mm. The average dead space was 3 μL in low dead space syringes with permanently attached needles, 13 μL in high dead space syringes with low dead space needles, 45 μL in low dead space syringes with high dead space needles, and 99 μL in high dead space syringes with high dead space needles. Among low dead space designs, calculated volumes of blood and HIV viral burden were lowest for low dead space syringes with permanently attached needles and highest for low dead space syringes with high dead space needles. The dead space in different low dead space needle and syringe combinations varied substantially. To reduce HIV transmission related to syringe sharing, needle and syringe programs need to combine this knowledge with the needs of their clients.

  3. Decontamination manual of RI handling laboratory

    International Nuclear Information System (INIS)

    Wadachi, Yoshiki

    2004-01-01

    Based on experiences in Japan Atomic Energy Research Institute (JAERI), the essential and practical knowledge of radioactive contamination and its decontamination, and the method and procedure of floor decontamination are described for researcher and managing person in charge of handling radioisotopes (RI) in RI handling laboratories. Essential knowledge concerns the uniqueness of solid surface contamination derived from RI half lives and quantities, surface contamination density limit, and mode/mechanism of contamination. The principle of decontamination is a single conduct with recognition of chemical form of the RI under use. As the practical knowledge, there are physical and chemical methods of solid surface decontamination. The latter involves use of inorganic acids, chelaters and surfactants. Removal and replacement of contaminated solid like floor material are often effective. Distribution mapping of surface contamination can be done by measuring the radioactivity in possibly contaminated areas, and is useful for planning of effective decontamination. Floor surface decontamination is for the partial and spread areas of the floor. It is essential to conduct the decontamination with reagent from the highly to less contaminated areas. Skin decontamination with either neutral detergent or titanium oxide is also described. (N.I.)

  4. NOTE: Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Science.gov (United States)

    Thompson, S. A.; Fung, A. Y. C.; Zaider, M.

    2002-08-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results.

  5. Ultrasonography-Guided Fine Needle Aspiration Cytology of Cervical Lymphadenopathy: Comparative Study of the Cytological Adequacy Using of 21- and 23- Gauge Needles

    International Nuclear Information System (INIS)

    Beak, Jin Wook; KIm, Dong Wook; Kim, Bo Mi

    2011-01-01

    To assess the difference in the cytological adequacy of ultrasonography (US)-guided fine needle aspiration cytology (US-FNAC) for cervical lymphadenopathy using 21 and 23 gauge needles. US-FNACs were separately performed on two cervical lymph nodes and in each patient using 21 gauge (group A) and 23 gauge (group B) needles, respectively. We used 4 grade classifications for the cytological analysis of each slide and compared the cytological adequacy of US-FNAC for cervical lymphadenopathy in the two groups. We performed US-FNACs on 58 cervical lymph nodes from 29 patients, with a cytological adequacy of 69.0%. The number of adequate cytological results was 19 (65.5%) in group A and 21 (72.4%) in group B, and the diagnostic adequacy did not differ significantly between the two groups (Mann-Whitney test, p = 0.574). There was no statistically significant difference in the cytological adequacy of US-FNAC for cervical lymphadenopathy according using of 21 and 23 gauge needles.

  6. Tritium handling experience at Atomic Energy of Canada Limited

    Energy Technology Data Exchange (ETDEWEB)

    Suppiah, S.; McCrimmon, K.; Lalonde, S.; Ryland, D.; Boniface, H.; Muirhead, C.; Castillo, I. [Atomic Energy of Canad Limited - AECL, Chalk River Laboratories, Chalk River, ON (Canada)

    2015-03-15

    Canada has been a leader in tritium handling technologies as a result of the successful CANDU reactor technology used for power production. Over the last 50 to 60 years, capabilities have been established in tritium handling and tritium management in CANDU stations, tritium removal processes for heavy and light water, tritium measurement and monitoring, and understanding the effects of tritium on the environment. This paper outlines details of tritium-related work currently being carried out at Atomic Energy of Canada Limited (AECL). It concerns the CECE (Combined Electrolysis and Catalytic Exchange) process for detritiation, tritium-compatible electrolysers, tritium permeation studies, and tritium powered batteries. It is worth noting that AECL offers a Tritium Safe-Handling Course to national and international participants, the course is a mixture of classroom sessions and hands-on practical exercises. The expertise and facilities available at AECL is ready to address technological needs of nuclear fusion and next-generation nuclear fission reactors related to tritium handling and related issues.

  7. Efficacy of Tuohy Needle in Oocytes Collection from Excised Mare Ovaries

    Directory of Open Access Journals (Sweden)

    F. Cremonesi

    2010-01-01

    Full Text Available Two methods have been described to recover oocytes from equine follicles in excised ovaries: aspiration and scraping. Aim of this work was to develop an effective method for collecting equine oocytes using Tuohy needle and comparing this technique to aspiration and scraping, with or without tunica albuginea removal. This hollow hypodermic needle, usually employed for inserting epidural catheters, is designed with a slightly curved tip, shaped similar to a small curette. In unpeeled ovaries, the recovery rates of Tuohy needle group was higher (<.05 than in the 16 g needle aspiration and in the scraped ovaries (57% versus 36% and 47% while the rate of cumulus-intact oocytes was higher than aspiration (46.9% versus 39.36% but lower than scraping (46.97% (<.001. In unpeeled ovaries there was significant difference in maturation rate of oocytes recovered by Tuohy needle in respect to peeled ovaries (58.54% versus 50.17%, resp.. Combination of aspiration and scraping by Tuohy needle allows a faster and reliable collection of oocytes suitable for horse IVM.

  8. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    Science.gov (United States)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  9. Knowledge and practices about hospital waste disposal and universal safety precautions in class IV employee.

    Science.gov (United States)

    Megha, Khobragade; Daksha, Pandit

    2013-01-01

    Norms and guidelines are formed for safe disposal of hospital waste but question is whether these guidelines are being followed and if so, to what extent. Hence, this study was conducted with objective to study the knowledge and practices about hospital waste disposal and universal safety precautions in class IV employee and to study its relationship with education, occupation and training. A cross-sectional study was carried out in a teaching hospital in Mumbai using semi-structured questionnaire in which Class IV employee were included. Questionnaire was filled by face to face interview. Data were analyzed using SPSS. 48.7% Class IV employee were not trained. More than 40% were following correct practices about disinfection of infectious waste. None of the respondents were using protective footwear while handling hospital waste. Only 25.5% were vaccinated for hepatitis B. 16% had done HIV testing due to contact with blood, body fluid, needle stick injury. Knowledge and practices about hospital waste disposal and universal precaution were statistically significant in trained respondents. Training of employees should be given top priority; those already in service should be given on the job training at the earliest.

  10. Confinement facilities for handling plutonium

    International Nuclear Information System (INIS)

    Maraman, W.J.; McNeese, W.D.; Stafford, R.G.

    1975-01-01

    Plutonium handling on a multigram scale began in 1944. Early criteria, equipment, and techniques for confining contamination have been superseded by more stringent criteria and vastly improved equipment and techniques for in-process contamination control, effluent air cleaning and treatment of liquid wastes. This paper describes the evolution of equipment and practices to minimize exposure of workers and escape of contamination into work areas and into the environment. Early and current contamination controls are compared. (author)

  11. [Therapeutic effect observation of chronic knee joint pain assisted with the central-square needling technique of the thumb-tack needles].

    Science.gov (United States)

    Yang, Yang; Qi, Si; Liu, Mengyue; Zhao, Yu; Li, Ning

    2017-10-12

    To compare the differences in the clinical therapeutic effects on chronic knee joint pain between the combination of the central-square needling technique of thumb-tack needles with the routine therapy of acupuncture, moxibustion and tuina and the routine therapy of acupuncture, moxibustion and tuina . One hundred and twenty patients of chronic knee joint pain were randomized into an observation group and a control group, 60 cases in each one. In the control group, the routine therapy of acupuncture, moxibustion and tuina was adopted. In the observation group, at the end of treatment with the routine therapy of acupuncture, moxibustion and tuina , the subcutaneous embedding therapy was followed with four thumb-tack needles at the sites 1 to 1.5 cm above, below and bilateral to the main point ( ashi point) separately, and the needles were retained for 24 h to 48 h. The treatment was given once every two days, three times a week, totally 6 times in two weeks; and the follow-up visit was done for 3 months in patients of the two groups. The visual analogue scale (VAS) score before and after each treatment, Lequesne index score before treatment and at the end of follow-up and the case numbers of proactive use of painkillers or receiving acupuncture treatment in the follow-up stage were compared and observed in the patients of the two groups. The VAS score was reduced gradually after treatment in the patients of the two groups. The differences were significant statistically after the second treatment as compared with those before the treatment in the two groups (all P 0.05). In the follow-up stage, there were 0 case in the observation group and 9 cases in the control group in terms of proactive use of painkillers ( P 0.05). The acupuncture scheme in assistance with the central-square needling technique of thumb-tack needles obviously relieves chronic knee joint pain, much better sustains the analgesic effects of acupuncture and improves patient compliance.

  12. Medication-handling challenges among visually impaired population

    Directory of Open Access Journals (Sweden)

    Ling Zhi-Han

    2017-01-01

    Full Text Available Objective: Visually impaired individuals are particularly at higher risk for experiencing a medication error. The aim of this study is to identify the problems encountered by the visually impaired population when handling their medication. Methods: A cross-sectional survey was conducted using an interviewer-guided questionnaire with 100 visually impaired individuals. The questionnaire comprised a series of questions in medication management. Results: All of the respondents perceived that self-administration of medication was a challenging task. A total of 89% of respondents were unable to read the prescription labels, 75% of respondents did not know the expiry date of their own medication, and 58% of respondents did not know the name of the medication. With regard to storage of medication, 72% of respondents did not practice appropriate methods to store their medication, and 80% of respondents kept the unused medication. All of the respondents disposed leftover medication through household rubbish. A total of 64% of respondents never practice medication review. Most (96% of them did not tell health-care providers when they faced difficulties in handling their medication. Conclusion: Most of the visually impaired individuals did not receive appropriate assistance regarding medicine use and having low awareness in medication management. This can lead to increased risk of medication errors or mismanagement among visually impaired population. Hence, effective strategies, especially in pharmaceutical care services, should be structured to assist this special population in medication handling.

  13. Textiles: Some technocal information and data IV: sewability, sewing needles, threads and seams.

    CSIR Research Space (South Africa)

    Hunter, L

    1979-09-01

    Full Text Available half in about four c~ro"dd5 - - - - . . - - . Reducing the needle \\docity during its contact with the fabric can reduce needle temocratures bv about 50°C although other workers found the differences ;o be only 5 to IPC14. ~adiation plays a minor..., may have led to the confusion concerning the relative merits of different needle point30. Needle point shape does not appear to significantly affect maximum penetration force or energy~ expended while bulged-eye needles reduce heat build...

  14. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  15. [Sleep disorder of schizophrenia treated with shallow needling: a randomized controlled trial].

    Science.gov (United States)

    Huang, Yanxi; Zheng, Ying

    2015-09-01

    To compare the clinical effective differences between shallow needling and medication for the sleep disorder of schizophrenia. Ninety-six patients with the sleep disorder of schizophrenia were randomly divided into a shallow needling group and a medication group, 48 cases in each one (one case dropping in the shallow needling group and two cases dropping in the medication group). The same dose paliperidone tablets were adopted in the two groups. In the shallow needling group, the main acupoints were Baihui (GV 20), Shangenxue (Extra) and Ezhongxian (MS 1), and the acupoints based on syndrome differentiation were selected. The shallow needling manipulation was used once a day, 5 times a week. In the medication group, 3 mg eszopiclone tablets were prescribed orally before sleep once every night. The patients were treated for 6 weeks in the two groups. Sleep condition was evaluated by Pittsburgh sleep quality index (PSQI) before and after treatment, and the clinical efficacy and the adverse reaction were assessed by positive and negative symptoms scale (PANSS) and treatment emergent symptom scale (TESS) before and after 2-week, 4-week and 6-week treatment. The clinical effects between the two groups were compared. After treatment in the two groups, both the total scores and the each factor score of the PSQI and the PANSS were apparently decreased (Pshallow needling group was reduced more obviously than that of the medication group (Pshallow needling group (Pshallow needling group was better than that in the medication group after treatment (Pshallow needling group after treatment (P0. 05). At the end of the 6th week, the curative and effective rate was 63. 9% (30/47) and the total effective rate was 95. 8% (45/47) in the shallow needling group;the curative and effective rate was 58. 7% (27/46) and the total effective rate was 91. 3% (42/46) in the medication group. The difference of the effect was not statistically significant between the two groups (P>0. 05). The

  16. A comparison of epicuticular wax of Pinus sylvestris needles from three sites in Ireland

    International Nuclear Information System (INIS)

    Donnelly, A.; Dowding, P.

    1994-01-01

    Three forest stands of Pinus sylvestris were chosen for comparison in Ireland. Needles from three year classes were collected. Cuticular transpiration curves showed that the rate of water loss from 1-year-old needles was faster than either 2-year-old or current-year needles at all sites. The amount of epicuticular wax extracted was similar to that reported in the literature. Needle wettability increased with needle age. Amorphous wax coverage was estimated using scanning electron microscopy (SEM) and was found to increase with needle age. Algal cells were noted on needles of all ages at one site and appeared to affect transpiration and microroughness. The presence of fungal hyphae was also noted. (orig.)

  17. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  18. Achievement of needle-like focus by engineering radial-variant vector fields.

    Science.gov (United States)

    Gu, Bing; Wu, Jia-Lu; Pan, Yang; Cui, Yiping

    2013-12-16

    We present and demonstrate a novel method for engineering the radial-variant polarization on the incident field to achieve a needle of transversally polarized field without any pupil filters. We generate a new kind of localized linearly-polarized vector fields with distributions of states of polarization (SoPs) describing by the radius to the power p and explore its tight focusing, nonparaxial focusing, and paraxial focusing properties. By tuning the power p, we obtain the needle-like focal field with hybrid SoPs and give the formula for describing the length of the needle. Experimentally, we systematically investigate both the intensity distributions and the polarization evolution of the optical needle by paraxial focusing the generated vector field. Such an optical needle, which enhances the light-matter interaction, has intriguing applications in optical microma-chining and nonlinear optics.

  19. Evaluating the advances and use of hypodermic needles in dentistry.

    Science.gov (United States)

    Boynes, Sean G

    2014-10-01

    Different injection techniques and patient management methodologies have been proposed to decrease the fear patients may have concerning dental needles. Dental providers should have an understanding of the technological advances, changes in techniques, and patient perceptions associated with the hypodermic needle. This article provides an overview of the pain perception process associated with dental injections. It reviews the two main sensory nerve fibers associated with injection pain and discusses needle properties as well as complications and adverse occurrences.

  20. 9 CFR 381.125 - Special handling label requirements.

    Science.gov (United States)

    2010-01-01

    ... AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY.... The safe handling information shall be set off by a border and shall be one color type printed on a single color contrasting background whenever practical. (2) (i) The labels of the poultry products...

  1. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  2. Teleoperation of steerable flexible needles by combining kinesthetic and vibratory feedback.

    Science.gov (United States)

    Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico

    2014-01-01

    Needle insertion in soft-tissue is a minimally invasive surgical procedure that demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and responsibility, autonomous robotic control is often not desirable. Therefore, it is necessary to focus also on techniques enabling clinicians to directly control the motion of the surgical tools. In this work, we address that challenge and present a novel teleoperated robotic system able to steer flexible needles. The proposed system tracks the position of the needle using an ultrasound imaging system and computes needle's ideal position and orientation to reach a given target. The master haptic interface then provides the clinician with mixed kinesthetic-vibratory navigation cues to guide the needle toward the computed ideal position and orientation. Twenty participants carried out an experiment of teleoperated needle insertion into a soft-tissue phantom, considering four different experimental conditions. Participants were provided with either mixed kinesthetic-vibratory feedback or mixed kinesthetic-visual feedback. Moreover, we considered two different ways of computing ideal position and orientation of the needle: with or without set-points. Vibratory feedback was found more effective than visual feedback in conveying navigation cues, with a mean targeting error of 0.72 mm when using set-points, and of 1.10 mm without set-points.

  3. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  4. Study on design and cutting parameters of rotating needles for core biopsy.

    Science.gov (United States)

    Giovannini, Marco; Ren, Huaqing; Cao, Jian; Ehmann, Kornel

    2018-06-15

    Core needle biopsies are widely adopted medical procedures that consist in the removal of biological tissue to better identify a lesion or an abnormality observed through a physical exam or a radiology scan. These procedures can provide significantly more information than most medical tests and they are usually performed on bone lesions, breast masses, lymph nodes and the prostate. The quality of the samples mainly depends on the forces exerted by the needle during the cutting process. The reduction of these forces is critical to extract high-quality tissue samples. The most critical factors that affect the cutting forces are the geometry of the needle tip and its motion while it is penetrating the tissue. However, optimal needle tip configurations and cutting parameters are not well established for rotating insertions. In this paper, the geometry and cutting forces of hollow needles are investigated. The fundamental goal of this study is to provide a series of guidelines for clinicians and surgeons to properly select the optimal tip geometries and speeds. Analytical models related to the cutting angles of several needle tip designs are presented and compared. Several needle tip geometries were manufactured from a 14-gauge cannula, commonly adopted during breast biopsies. The needles were then tested at different speeds and on different phantom tissues. According to these experimental measurements recommendations were formulated for rotating needle insertions. The findings of this study can be applied and extended to several biopsy procedures in which a cannula is used to extract tissue samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Reliability of pressure waveform analysis to determine correct epidural needle placement in labouring women.

    Science.gov (United States)

    Al-Aamri, I; Derzi, S H; Moore, A; Elgueta, M F; Moustafa, M; Schricker, T; Tran, D Q

    2017-07-01

    Pressure waveform analysis provides a reliable confirmatory adjunct to the loss-of-resistance technique to identify the epidural space during thoracic epidural anaesthesia, but its role remains controversial in lumbar epidural analgesia during labour. We performed an observational study in 100 labouring women of the sensitivity and specificity of waveform analysis to determine the correct location of the epidural needle. After obtaining loss-of-resistance, the anaesthetist injected 5 ml saline through the epidural needle (accounting for the volume already used in the loss-of-resistance). Sterile extension tubing, connected to a pressure transducer, was attached to the needle. An investigator determined the presence or absence of a pulsatile waveform, synchronised with the heart rate, on a monitor screen that was not in the view of the anaesthetist or the parturient. A bolus of 4 ml lidocaine 2% with adrenaline 5 μg.ml -1 was administered, and the epidural block was assessed after 15 min. Three women displayed no sensory block at 15 min. The results showed: epidural block present, epidural waveform present 93; epidural block absent, epidural waveform absent 2; epidural block present, epidural waveform absent 4; epidural block absent, epidural waveform present 1. Compared with the use of a local anaesthetic bolus to ascertain the epidural space, the sensitivity, specificity, positive and negative predictive values of waveform analysis were 95.9%, 66.7%, 98.9% and 33.3%, respectively. Epidural waveform analysis provides a simple adjunct to loss-of-resistance for confirming needle placement during performance of obstetric epidurals, however, further studies are required before its routine implementation in clinical practice. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  6. Spinal anaesthesia in young patients: evaluation of needle gauge ...

    African Journals Online (AJOL)

    Background:The well-known complication of spinal anaesthesia, postdural puncture headache (PDPH), is especially troublesome in young patients. The needle gauge and configuration of needle tip appear to be the important factors in reducing the incidence of PDPH; however it may increase the incidence of technical ...

  7. Needle-Stick Injury among Health Care Workers in Hemodialysis Units in Nigeria: A Multi-Center Study

    Directory of Open Access Journals (Sweden)

    CO Amira

    2014-01-01

    Full Text Available Background: Needle-stick and sharps injuries carry the risk of infection and are occupational hazards for all health care professionals involved in clinical care. Objective: To determine the frequency and factors contributing to needle-stick injury (NSI among health care workers of dialysis units in Lagos, Nigeria. Methods: Data were obtained by anonymous, self-reporting questionnaire from staff of 4 hemodialysis units between October and December 2011. Information on demographics, job category and duration, details of NSI in the past, kind of activity and procedure under which the NSI occurred, if injury was reported, vaccination status of staff, and post-exposure treatment received were obtained. Results: The study population included 38 (37.3% doctors, 42 nurses (41.2%, 14 (13.7% dialysis technicians and 8 (7.8% ancillary staff. There were 39 (38.2% males. The mean±SD age of the study population was 34.4±8.3 years. 25 (24.5% staff had suffered NSI in the last 12 months and 41 (40.2% in their entire working career. The most common activity leading to NSI was recapping of needles (45%, improper disposal of needles (30%, and venous cannulation and setting of drips (27.5%. NSI was significantly (p=0.016 higher among those with work experience between 6 and 10 years than others. Hollow bore needles were responsible for 82.9% of the NSIs. Only 15 (37% respondents reported their NSI to their unit head or designated officer in order to get medical advice. Conclusion: In Lagos, Nigeria, NSI is common among hemodialysis staff and is under-reported. Many NSIs can be prevented by adhering to the practice of universal precautions as well as education of staff on such precautionary methods.

  8. Lumbar punction: comparison between an atraumatic and a traumatic punction needle

    Directory of Open Access Journals (Sweden)

    Tina Bregant

    2017-03-01

    Full Text Available Background: Lumbar puncture is a standardized, routine diagnostic procedure in the diagnosis of neurological diseases. Post-duarl puncture headache (PDPH is a common complication which occurs in 10 to 30 % of patients. Although the incidence of PDPH is much lower with the use of small, non-cutting needles, neurologists in Slovenia routinely use the classical traumatic spinal needles.Methods: In the article we provide an overview of a research concerned with the use of traumatic and atraumatic needles in the procedure with the emphasis on complications of the lumbar puncture. We present American and European recommendations for lumbar puncture procedure.Conclusions: International recommendations for neurologists advise the use of atraumatic spinal needles for lumbar puncture. We recommend to Slovenian neurologists to start using the atraumatic needles for elective lumbar punctures and hence provide neurological patients with better quality and cheaper long-term care.

  9. Prevalence of Needle Stick Injuries among Healthcare Workers in ...

    African Journals Online (AJOL)

    Background: Needle stick injuries represent one of the most important occupational hazards to which health workers are exposed. These injuries result from accidental piercing of the skin and or mucous membranes by sharp objects. Needle stick injuries carry the risk of exposure to blood-borne pathogens, especially ...

  10. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  11. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Directory of Open Access Journals (Sweden)

    Shaoli Liu

    Full Text Available The "robotic-assisted liver tumor coagulation therapy" (RALTCT system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1 multiple needles are needed to destroy the entire tumor, (2 the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3 the placement of multiple needles should avoid interference with each other, (4 an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5 the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW, which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor

  12. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Science.gov (United States)

    Liu, Shaoli; Xia, Zeyang; Liu, Jianhua; Xu, Jing; Ren, He; Lu, Tong; Yang, Xiangdong

    2016-01-01

    The "robotic-assisted liver tumor coagulation therapy" (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy

  13. Needle Biopsy of the Lung

    Science.gov (United States)

    ... clip. The needle is hollow so it can capture the tissue specimen. There are several types of ... breath, difficulty in catching your breath, rapid pulse (heart rate), sharp chest or shoulder pain with breathing, ...

  14. Controlling fugitive dust emissions in material handling operations

    Energy Technology Data Exchange (ETDEWEB)

    Tooker, G E

    1992-05-01

    The primary mechanism of fugitive dust generation in bulk material handling transfer operations is by dispersion of dust in turbulent air induced to flow with falling or projected material streams. This paper returns to basic theories of particle dynamics and fluid mechanics to quantify the dust generating mechanism by rational analysis. Calculations involving fluid mechanisms are made easier by the availability of the personal computer and the many math manipulating programs. Rational analysis is much more cost effective when estimating collection air volumes to control fugitive emissions; especially in enclosed material handling transfers transporting large volumes of dusty material. Example calculations, using a typical enclosed conveyor-to-conveyor transfer operation are presented to illustrate and highlight the key parameters that determine the magnitude of induced air flow that must be controlled. The methods presented in this paper for estimating collection air volumes apply only enclosed material handling transfers, exhausted to a dust collector. Since some assistance to the control of dust emissions must be given by the material handling transfer chute design, a discussion of good transfer chute design practice is presented. 4 refs., 2 figs., 2 tabs.

  15. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@umcutrecht.nl; Maenhout, Metha; Lagendijk, Jan J. W.; Vulpen, Marco van; Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands and IMB, UMR 5251 CNRS/University of Bordeaux, Talence 33400 (France); Hautvast, Gilion; Binnekamp, Dirk [Philips Group Innovation Biomedical Systems, Eindhoven 5656 AE (Netherlands)

    2016-10-15

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position

  16. Safe injection practice among health-care workers in Gharbiya Governorate, Egypt.

    Science.gov (United States)

    Ismail, N A; Aboul Ftouh, A M; El-Shoubary, W H; Mahaba, H

    2007-01-01

    We assessed safe injection practices among 1100 health-care workers in 25 health-care facilities in Gharbiya Governorate. Questionnaires were used to collect information and 278 injections were observed using a standardized checklist. There was a lack of infection control policies in all the facilities and a lack of many supplies needed for safe injection. Proper needle manipulation before disposal was observed in only 41% of injections, safe needle disposal in 47.5% and safe syringe disposal in 0%. Reuse of used syringes and needles was reported by 13.2% of the health-care workers and 66.2% had experienced a needle-stick injury. Only 11.3% had received a full course of hepatitis B vaccination.

  17. Accumulation of Cs 137 by needles of pinus silvestris in various types of forest

    International Nuclear Information System (INIS)

    Golushko, R.M.

    2002-01-01

    It is researched accumulation of Cs 137 by needles of pine trees during growing old. It is shown, that needles of the one year old have more high radioactivity than needles of the two or three years old. Needles of pine trees accumulated more Cs 137 on good wet soils

  18. Fertilization Changes Chemical Defense in Needles of Mature Norway Spruce (Picea abies

    Directory of Open Access Journals (Sweden)

    Line Nybakken

    2018-06-01

    Full Text Available Nitrogen availability limits growth in most boreal forests. However, parts of the boreal zone receive significant levels of nitrogen deposition. At the same time, forests are fertilized to increase volume growth and carbon sequestration. No matter the source, increasing nitrogen in the boreal forest ecosystem will influence the resource situation for its primary producers, the plants, with possible implications for their defensive chemistry. In general, fertilization reduces phenolic compound concentrations in trees, but existing evidence mainly comes from studies on young plants. Given the role of the phenolic compounds in protection against herbivores and other forest pests, it is important to know if phenolics are reduced with fertilization also in mature trees. The evergreen Norway spruce is long-lived, and it is reasonable that defensive strategies could change from the juvenile to the reproductive and mature phases. In addition, as the needles are kept for several years, defense could also change with needle age. We sampled current and previous year needles from an N fertilization experiment in a Norway spruce forest landscape in south-central Norway to which N had been added annually for 13 years. We analyzed total nitrogen (N and carbon (C, as well as low-molecular phenolics and condensed tannins. Needles from fertilized trees had higher N than those from controls plots, and fertilization decreased concentrations of many flavonoids, as well as condensed tannins in current year needles. In previous year needles, some stilbenes and condensed tannins were higher in fertilized trees. In control trees, the total phenolic concentration was almost five times as high in previous year needles compared with those from the current year, and there were great compositional differences. Previous year needles contained highest concentrations of acetophenone and stilbenes, while in the current year needles the flavonoids, and especially coumaroyl

  19. The experimental assessment of dynamic tire handling performance

    NARCIS (Netherlands)

    Pauwelussen, J.P.

    1999-01-01

    Testing of steady state tire handling performance is nowadays common practice with slip angle sweeps and breaking being simulated in the laboratory with drum or flat belt, or on the road with a test trailer. In recent years, more emphasis is put on dynamic tire models, motivated by ride comfort

  20. Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hongming Song

    2015-01-01

    Full Text Available Background. Fine needle aspiration cytology (FNAC and fine needle nonaspiration cytology (FNNAC are useful cost-effective techniques for preoperatively assessing thyroid lesions. Both techniques have advantages and disadvantages, and there is controversy over which method is superior. This meta-analysis was performed to evaluate the differences between FNAC and FNNAC for diagnosis of thyroid nodules. Methods. Primary publications were independently collected by two reviewers from PubMed, Web of Science, Google Scholar, EBSCO, OALib, and the Cochrane Library databases. The following search terms were used: fine needle, aspiration, capillary, nonaspiration, sampling without aspiration, thyroid, and cytology. The last search was performed on February 1, 2015. Results. Sixteen studies comprising 1,842 patients and 2,221 samples were included in this study. No statistically significant difference was observed between FNAC and FNNAC groups with respect to diagnostically inadequate smears, diagnostically superior smears, diagnostic performance (accuracy, sensitivity, specificity, negative predictive value, and positive predictive value, area under the summary receiver operating characteristic curve, average score of each parameter (background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture, and total score of five parameters. Conclusion. FNAC and FNNAC are equally useful in assessing thyroid nodules.

  1. Fabrication and optical characterization of cadmium sulfide needles using nuclear track membrane

    International Nuclear Information System (INIS)

    Peng, L.Q.; Wang, S.C.; Ju, X.; Xiao, H.; Chen, H.; He, Y.J.

    1999-01-01

    Cadmium sulfide needles with a diameter of 0.2 μm have been fabricated in nuclear track polyethylene-terephthalate (PET) membrane by electrochemically depositing from organic solvent dimethylsulfoxide (DMSO) containing CdCl 2 and elemental sulfur at the temperature 110 deg. C. The characterization of the sample of CdS needles was studied by scanning electron microscope, X-ray diffraction, absorption and photoluminescence spectra. The optical experiments show that in the sample of CdS needles there is an absorption peak that could be assigned to the interface states of the CdS needles

  2. Fabrication and optical characterization of cadmium sulfide needles using nuclear track membrane

    Energy Technology Data Exchange (ETDEWEB)

    Peng, L.Q.; Wang, S.C.; Ju, X.; Xiao, H.; Chen, H.; He, Y.J

    1999-06-01

    Cadmium sulfide needles with a diameter of 0.2 {mu}m have been fabricated in nuclear track polyethylene-terephthalate (PET) membrane by electrochemically depositing from organic solvent dimethylsulfoxide (DMSO) containing CdCl{sub 2} and elemental sulfur at the temperature 110 deg. C. The characterization of the sample of CdS needles was studied by scanning electron microscope, X-ray diffraction, absorption and photoluminescence spectra. The optical experiments show that in the sample of CdS needles there is an absorption peak that could be assigned to the interface states of the CdS needles.

  3. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  4. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  5. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    Science.gov (United States)

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  6. Enhanced Visualization of Fine Needles Under Sonographic Guidance Using a MEMS Actuator

    Directory of Open Access Journals (Sweden)

    Zhiyuan Shen

    2015-01-01

    Full Text Available Localization of a needle tip is important for biopsy examinations in clinics. However, the needle tip is sometimes difficult to discern under the guidance of sonography due to its poor visibility. A mini actuator that radiates a low-intensity ultrasound wave was manufactured using micro-electro-mechanical system (MEMS technology. Interference between the radiated and diagnostic ultrasound pulses was observed as bright lines in the B-mode ultrasound image, from which the mini actuator could be recognized with ease. Because the distance between the mini actuator and the needle tip is fixed, the needle tip can be determined despite its inconsistent appearance in the sonography. Both gel phantom and ex vivo tissue evaluation showed that the needle tip can be determined reliably utilizing the acoustic interference pattern.

  7. Effect of ponderosa pine needle litter on grass seedling survival.

    Science.gov (United States)

    Burt R. McConnell; Justin G. Smith

    1971-01-01

    Hard fescue survival rates were followed for 6 years on four different pine needle treatment plots. Needle litter had a significant effect on initial survival of fescue seedlings, but subsequent losses undoubtedly resulted from the interaction of many factors.

  8. [Emergence of novel psychoactive substances among clients of a needle exchange program in Budapest, Hungary].

    Science.gov (United States)

    Rácz, József; Csák, Róbert

    2014-08-31

    In this paper the authors summarize experience of a drug service provider with the injecting use of novel psychoactive substances. Among clients of the needle exchange programme of Blue Point Drug Counselling and Outpatient Centre, the authors observed the spread of the novel substances since 2009. The extensive spread of the novel substances caused substantial change in injecting use patterns, thus in the usage of the needle exchange programme. The novel psychoactive substances appeared consecutively, so that this setting gave a unique opportunity to observe and track the emergence of these substances. The authors summarize the characteristics which are important for medical practice (risks, frequent use, severe psychopathological conditions) as well as special risks associated with these substances (substances with unknown composition and effect). They highlight the importance and role of the early warning system, monitoring the online sources of information and testing of samples containing novel psychoactive substances.

  9. Driven Around the Bend: Novel Use of a Curved Steerable Needle

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Darra T., E-mail: darra.murphy@vch.ca; Korzan, Jeffrey R.; Ouellette, Hugue A.; Liu, David M. [Vancouver General Hospital, Department of Radiology (Canada); Clarkson, Paul W. [Vancouver General Hospital, Department of Orthopedic Surgery (Canada); Munk, Peter L. [Vancouver General Hospital, Department of Radiology (Canada)

    2013-04-15

    This technical note describes the novel use of a curved, steerable needle to access symptomatic osseous lesions in the pelvis and sacrum for palliative percutaneous treatment that would otherwise be difficult to treat using conventional straight needles. Seven patients with lytic bone lesions were treated. One patient had multiple myeloma; the remaining had metastatic disease: breast carcinoma (n = 2), colorectal carcinoma (n = 1), renal cell carcinoma (n = 1), squamous cell carcinoma (n = 1), and leiomyosarcoma (n = 1). Five of the seven patients had lesions in the posterior acetabulum, and the two other patients had lesions in the sacrum. Four of the seven patients received radiofrequency ablation followed by cementoplasty; three patients received cementation alone. We used a novel needle designed for vertebroplasty, which has an articulating tip allowing it to be guided into lytic bone lesions located in difficult-to-access regions of the pelvis and sacrum. All patients were successfully treated with cementoplasty either with or without thermal ablation. No serious adverse events were reported. The needle was difficult to withdraw in two patients. Steerable curved needles can be successfully used to treat lytic osseous metastases with cementoplasty when lesions are located in sites that may be difficult to reach using conventional straight needles.

  10. Darning Needle Impacted in the Male Urethra | Singla | African ...

    African Journals Online (AJOL)

    Foreign bodies of varied nature have been introduced into the urethra to achieve sexual stimulation. We report the case of a long (9.5 cm) darning needle impacted in the urethra of a male patient following urethral masturbation. After a failed trial at endoscopic extraction the needle had to be removed via open surgery.

  11. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  12. Handling of multiassembly sealed baskets between reactor storage and a remote handling facility

    International Nuclear Information System (INIS)

    Massey, J.V.; Kessler, J.H.; McSherry, A.J.

    1989-06-01

    The storage of multiple fuel assemblies in sealed (welded) dry storage baskets is gaining increasing use to augment at-reactor fuel storage capacity. Since this increasing use will place a significant number of such baskets on reactor sites, some initial downstream planning for their future handling scenarios for retrieving multi-assembly sealed baskets (MSBs) from onsite storage and transferring and shipping the fuel (and/or the baskets) to a federally operated remote handling facility (RHF). Numerous options or at-reactor and away-from-reactor handling were investigated. Materials handling flowsheets were developed along with conceptual designs for the equipment and tools required to handle and open the MSBs. The handling options were evaluated and compared to a reference case, fuel handling sequence (i.e., fuel assemblies are taken from the fuel pool, shipped to a receiving and handling facility and placed into interim storage). The main parameters analyzed are throughout, radiation dose burden and cost. In addition to evaluating the handling of MSBs, this work also evaluated handling consolidated fuel canisters (CFCs). In summary, the handling of MSBs and CFCs in the store, ship and bury fuel cycle was found to be feasible and, under some conditions, to offer significant benefits in terms of throughput, cost and safety. 14 refs., 20 figs., 24 tabs

  13. Needle displacement during HDR brachytherapy in the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Damore, Steven J.; Syed, A.M. Nisar; Puthawala, Ajmel A.; Sharma, Anil

    2000-01-01

    Purpose: We used clinical patient data to examine implant displacement between high dose rate (HDR) brachytherapy fractions for prostate cancer to determine its impact on treatment delivery. Materials and Methods: We analyzed the verification films taken prior to each fraction for 96 consecutive patients treated with HDR brachytherapy boosts as part of their radiation therapy for definitive treatment of organ-confined prostate cancer at our institution. Patients were treated with 18-24 Gy in 4 fractions of HDR delivered in 40 hours followed by 36-39.6 Gy external beam radiation to the prostate. We determined the mean and maximum displacement distances of marker seeds placed in the prostate and of the implanted needles between HDR fractions. Results: Mean and maximum displacement distances between fractions were documented up to 7.6 mm and 28.5 mm, respectively, for the implant needles and 3.6 mm and 11.4 mm, respectively, for the gold marker seeds. All displacement of implant needles occurred in the caudal direction. At least 1 cm caudal displacement of needles occurred prior to 15.5% all fractions. Manual adjustment of needles was required prior to 15% of fractions, and adjustment of the CLP only was required in 24%. Most of the displacement for both the marker seeds and needles occurred between the first and second fractions. Conclusions: There is significant caudal displacement of interstitial implant needles between HDR fractions in our prostate cancer patients. Obtaining verification films and making adjustments in the treatment volume prior to each fraction is necessary to avoid significant inaccuracies in treatment delivery

  14. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  15. Photosynthesis in Norway spruce seedlings infected by the needle rust Chrysomyxa rhododendri.

    Science.gov (United States)

    Bauer, Helmut; Plattner, Karin; Volgger, Waltraud

    2000-02-01

    Chrysomyxa rhododendri (DC.) De Bary is a needle rust with a host shift between Rhododendron sp. and Norway spruce (Picea abies (L.) Karst.), penetrating only the new developing flushes of the conifer. Because little is known about its effects on trees, we investigated several parameters related to photosynthesis in artificially infected 3-year-old Norway spruce seedlings. The potential efficiency of photosystem II (PSII; derived from chlorophyll fluorescence measurements) was reduced in infected current-year needles as soon as disease symptoms were visible, about three weeks after inoculation. Two weeks later, photosynthetic O(2) evolution (P(max)) of infected needles was less than 20% of control needles, whereas respiratory O(2) uptake (R(D)) was about three times higher than that of control needles. Nonstructural carbohydrate concentrations were about 60% of control values in all parts of the shoots of infected trees. Photosynthetic inhibition was associated with marked decreases in chlorophyll concentration and chlorophyll a/b ratio but only a small reduction in carotenoid concentration. In infected trees, P(max) of noninfected 1-year-old and 2-year-old needles was 50 and 80% higher than in the corresponding age class of needles of control trees. Estimation of potential daily net dry mass production, based on P(max), R(D), specific leaf area, carbon content and needle biomass, indicated that seedlings infected once were able to produce 60%, and those infected twice only 25%, of the dry mass of controls. We conclude that afforestation and regeneration of Norway spruce is seriously impaired in regions where seedlings are frequently attacked by Chrysomyxa.

  16. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1

  17. Nuclear fuel handling apparatus

    International Nuclear Information System (INIS)

    Andrea, C.; Dupen, C.F.G.; Noyes, R.C.

    1977-01-01

    A fuel handling machine for a liquid metal cooled nuclear reactor in which a retractable handling tube and gripper are lowered into the reactor to withdraw a spent fuel assembly into the handling tube. The handling tube containing the fuel assembly immersed in liquid sodium is then withdrawn completely from the reactor into the outer barrel of the handling machine. The machine is then used to transport the spent fuel assembly directly to a remotely located decay tank. The fuel handling machine includes a decay heat removal system which continuously removes heat from the interior of the handling tube and which is capable of operating at its full cooling capacity at all times. The handling tube is supported in the machine from an articulated joint which enables it to readily align itself with the correct position in the core. An emergency sodium supply is carried directly by the machine to provide make up in the event of a loss of sodium from the handling tube during transport to the decay tank. 5 claims, 32 drawing figures

  18. Tattoo machines, needles and utilities.

    Science.gov (United States)

    Rosenkilde, Frank

    2015-01-01

    Starting out as a professional tattooist back in 1977 in Copenhagen, Denmark, Frank Rosenkilde has personally experienced the remarkable development of tattoo machines, needles and utilities: all the way from home-made equipment to industrial products of substantially improved quality. Machines can be constructed like the traditional dual-coil and single-coil machines or can be e-coil, rotary and hybrid machines, with the more convenient and precise rotary machines being the recent trend. This development has resulted in disposable needles and utilities. Newer machines are more easily kept clean and protected with foil to prevent crosscontaminations and infections. The machines and the tattooists' knowledge and awareness about prevention of infection have developed hand-in-hand. For decades, Frank Rosenkilde has been collecting tattoo machines. Part of his collection is presented here, supplemented by his personal notes. © 2015 S. Karger AG, Basel.

  19. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  20. Procedure of safe handling with cytostatic drugs

    Directory of Open Access Journals (Sweden)

    Kodžo Dragan

    2003-01-01

    Full Text Available Working group for safe handling with cytostatic drugs has been formed by the Ministry of Health, and it consists of professionals from IORS, Federal Bureau of Weights and Measures, Industrial Medicine, Institute of Hematology, Military Medical Academy, and Crown Agents. The aim of this working group is to prepare procedures for safe handling with cytostatic drugs, as well as program for educational seminar for nurses, medical technicians, and pharmaceutical technicians. The procedures will serve as a guide of good practice of oncology health care, and will refer to all actions that health care professionals carry out from the moment of drugs arrival to the pharmacy to the moment of their application. In the first segment of this procedure, general rules are given for working with cytotoxic agents, control for risky exposures, safe system of work, control of working environment, monitoring of the employees' health condition adequate protection in the working environment, protective equipment of the employees (gloves, mask, cap, eyeglasses, shoe covers, coats and chambers for vertical laminary air stream. Storing of cytostatics, procedure in case of accident, and waste handling and removal are also described in this segment. Fifty-three standard operational procedures are described in detail in the second segment. Training scheme for preparation of chemotherapy is given in the third segment - education related to various fields and practical part, which would be carried out through workshops, and at the end of the course participants would pass a test and obtain certificate. After the procedures for safe handling with cytostatics are legally regulated employer will have to provide minimum of protective equipment, special rooms for the drugs dissolving, chambers with laminar airflow, 6 hours working time, rotation of the staff working with drugs dissolving in intervals of every five years, higher efficiency, better health control. In conclusion

  1. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  2. Anomalous needle numbers on dwarf shoots of Pinus mugo and P. uncinata (Pinaceae

    Directory of Open Access Journals (Sweden)

    Krystyna Boratyńska

    2011-01-01

    Full Text Available The frequency of occurrence of abnormal, three- (or more needle dwarf shoots of most southern and central European two-needle pine (Pinus species were studied. No specimens with more than two-needle dwarf shoots were found in a population of P. nigra Arnold subsp. salzmannii (Dunal Franco from the Iberian Peninsula and in two populations of P. uliginosa Neumann from the Sudeten Mountains in Central Europe. Single specimens were found within one population of P. pinaster Aiton from the Iberian Peninsula and among six populations of P. sylvestris L. from the Iberian Peninsula and Central Europe. Abnormal dwarf shoots mostly with three, but also four, five or six needles were found among 24 of 25 surveyed populations of P. mugo Turra and P. uncinata Ramond. The average frequency of specimens with at least one three-needle dwarf shoot was 24% for P. mugo and 20% for P. uncinata. The frequencies of occurrence varied significantly among studied populations and were highest in samples collected from the upper elevational range limits of the species in the mountains and near the northern limits of their ranges. The frequency of abnormal dwarf shoots in the same populations was significantly high in 2-3 consecutive years. Needles from three-needle dwarf shoots were not significantly shorter than those of two-needle shoots.

  3. Aerosols on the surface of needles in the vicinity of Winterthur

    International Nuclear Information System (INIS)

    Wyttenbach, A.; Tobler, L.; Bajo, S.

    1991-01-01

    The composition and the mass of aerosols residing on the surface of one-year-old needles of Norway spruce are described. The composition of aerosols on spruce needles is compared with that of aerosols collected by air filters and the composition of the local soil. A comparison of the years 1982 and 1985 shows virtually identical conditions. Finally, possible connections between aerosol mass and inherent needle content are discussed. (author) 5 figs., 2 tabs., 13 refs

  4. How to Handle Difficult Parents: Proven Solutions for Teachers. Second Edition

    Science.gov (United States)

    Tingley, Suzanne Capek

    2012-01-01

    "How to Handle Difficult Parents" is a funny, but practical, guide to working effectively with parents and avoiding unnecessary conflict. Whether you're a teacher (regular or special education) or a coach, this book will give you practical suggestions regarding what to say and how to say it to parents who question your lesson plans, challenge your…

  5. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  6. CT-guided core biopsy of malignant lung lesions: how many needle passes are needed?

    International Nuclear Information System (INIS)

    Lim, Chaehun; Han, Dae Hee; Lee, Kyo Young; Kim, Young Kyoon; Ko, Jeong Min

    2013-01-01

    The study aims to determine the number of needle pass in the CT-guided core needle biopsy (CNB) in making a diagnosis of pulmonary malignancy. A total of 434 CNB records were retrospectively reviewed. The specimen obtained from each needle pass was put in a formalin container and then labelled for separate histopathological reporting. The patients were divided into five groups according to the total number of needle passes (n=1, n=2, n=3, n=4 and n≥5). In each of the groups 2–4, it was analysed how many needle passes are required before a plateau in diagnostic yield is achieved. CNB produced 283 true-positive and 23 false-negative diagnosis of malignancy. Cumulative sensitivity significantly (P<0.05) increased between the first and second as well as the second and the third (if done) needle passes, but not between the third and fourth ones. Three coaxial needle passes might be optimal in the diagnosis of lung malignancy.

  7. Synthesis and Characterization of Pine Needles Reinforced RF Matrix Based Biocomposites

    Directory of Open Access Journals (Sweden)

    A. S. Singha

    2008-01-01

    Full Text Available Synthesis and characterization of pine needles reinforced thermosetting resin (Resorcinol-Formaldehyde which is most suitable as composite matrix has been reported. The polycondensation reaction between resorcinol and formaldehyde (RF in different molar ratios has been applied to the synthesis of RF polymer matrix. A thermosetting resin based composite, containing approximately 10, 20, 30 and 40% of natural fiber by weight, has been obtained by adding pine needles to the Resorcinol-Formaldehyde (RF resin. The mechanical properties of randomly oriented intimately mixed particle reinforced (Pine needles composites were determined. Effect of fiber loading in terms of weight % on mechanical properties such as tensile, compressive, and flexural and wear properties have also been evaluated. The reinforcing of the resin with Pine needles was accomplished in particle size of 200 micron by employing optimized resin. Present work reveals that mechanical properties of the RF resin increases to extensive extent when reinforced with Pine needles. Thermal (TGA/DTA and morphological studies (SEM of the resin, fiber and polymer composites thus synthesized have also been carried out.

  8. [Acupuncture therapy for regaining consciousness in terms of acupoint location, needle insertion and needle manipulation].

    Science.gov (United States)

    Meng, Xianggang; Gu, Wenlong; Ma, Fen; Du, Yuzheng; Zhao, Qi

    2015-03-01

    Acupuncture therapy for regaining consciousness activates soreness, numbness, distention, heaviness, radiating and moving, electric shock and ant climbing sensations at the specific acupoints in the stroke patients. Radiating and moving sensations are the summary of needling sensations such as soreness, numbness and twitching presenting during lifting and thrusting manipulation. These sensations are the essential factors of the therapeutic effect of regaining consciousness. Radiating sensation refers to the conduction along meridians and radiation of soreness and numbness. Moving sensation refers to the local muscular twitching at acupoints and the involuntary movement of limbs, joints and the distal. Acupuncture at the specific acupoints achieves radiating and moving sensations for promoting the circulation in meridians, regulating qi and mind and balancing yin and yang in stroke patients. This therapy was introduced in the paper in view of acupoint location, needle insertion and manipulation.

  9. Health Education in Practice: Employee Conflict Resolution Knowledge and Conflict Handling Strategies

    Science.gov (United States)

    Hackett, Alexis; Renschler, Lauren; Kramer, Alaina

    2014-01-01

    The purpose of this project was to determine if a brief workplace conflict resolution workshop improved employee conflict resolution knowledge and to examine which conflict handling strategies (Yielding, Compromising, Forcing, Problem-Solving, Avoiding) were most used by employees when dealing with workplace conflict. A pre-test/post-test control…

  10. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety.

    Science.gov (United States)

    Fujii, Chieko

    2013-01-01

    Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures. Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined. Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed. This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.

  11. Jaques-Louis Reverdin (1842-1929): the surgeon and the needle.

    Science.gov (United States)

    Fariña-Pérez, Luis A

    2010-05-01

    With the development and rise of abdominal laparoscopic techniques, the old Reverdin needle has had a revival, because it proved to be useful for the endoscopic closure of laparoscopic access ports, in order to lower the incidence of incisional hernias. Several new modifications of the Reverdin needle, with different names, are in the market now. This new use of an old instrument, prompted a review of the life and work of Jaques-Louis Reverdin, the Swiss surgeon trained in Paris and founder of the modern Swiss surgery. Biographical and bibliographical review of Jaques-MLouis Reverdin and his contributions to surgery Jaques-Louis Reverdin (1842-1929), born in Geneva, completed his medical studies in Paris, where he practised in several well-known hospitals such as La Pitié (with Goselin), Saint Louis (with Guérin), Lariboisiére, and Necker (with Guyon). In 1869 he published and presented in several meetings, a pioneering experience of successful free skin graft procedure, that is still performed in some cases and constitutes the first organ transplantation. In 1870 he presented his doctoral thesis "Etude sur l'uréthrotomie interne" with the expeience of his master Guyon (63 operations), gaining the Civiale prize and the bronze medal of the Paris Faculty of Medicine. He returned back to Geneva in 1872 to begin a long surgical practice and Faculty teaching, and he made seminal contributions to the knowledge of thyroid diseases, in particular on the clinical presentation of function deficiency following exeresis of the thyroid gland ( postoperative myxoedema). His contributions paralleled that made by Theodor Kocher in Bern, the surgeon that received in solitary the Nobel prize for these studies in 1909. With Jean6hyphen;Louis Prevost and Constant Picot, they founded the "Revue medicale de la Suisse romande", the most important Swiss medical journal of the 20th century. He is remembered in the field of Urology for a special needle designed to pass through a suture

  12. Facile fabrication of super-hydrophobic nano-needle arrays via breath figures method.

    Science.gov (United States)

    Kim, Jiseok; Lew, Brian; Kim, Woo Soo

    2011-12-06

    Super-hydrophobic surfaces which have been fabricated by various methods such as photolithography, chemical treatment, self-assembly, and imprinting have gained enormous attention in recent years. Especially 2D arrays of nano-needles have been shown to have super-hydrophobicity due to their sharp surface roughness. These arrays can be easily generated by removing the top portion of the honeycomb films prepared by the breath figures method. The hydrophilic block of an amphiphilic polymer helps in the fabrication of the nano-needle arrays through the production of well-ordered honeycomb films and good adhesion of the film to a substrate. Anisotropic patterns with water wettability difference can be useful for patterning cells and other materials using their selective growth on the hydrophilic part of the pattern. However, there has not been a simple way to generate patterns with highly different wettability. Mechanical stamping of the nano-needle array with a polyurethane stamp might be the simplest way to fabricate patterns with wettability difference. In this study, super-hydrophobic nano-needle arrays were simply fabricated by removing the top portion of the honeycomb films. The maximum water contact angle obtained with the nano-needle array was 150°. By controlling the pore size and the density of the honeycomb films, the height, width, and density of nano-needle arrays were determined. Anisotropic patterns with different wettability were fabricated by simply pressing the nano-needle array at ambient temperature with polyurethane stamps which were flexible but tough. Mechanical stamping of nano-needle arrays with micron patterns produced hierarchical super-hydrophobic structures.PACS: 05.70.Np, 68.55.am, 68.55.jm.

  13. Transcription through the eye of a needle: daily and annual cyclic gene expression variation in Douglas-fir needles.

    Science.gov (United States)

    Cronn, Richard; Dolan, Peter C; Jogdeo, Sanjuro; Wegrzyn, Jill L; Neale, David B; St Clair, J Bradley; Denver, Dee R

    2017-07-24

    Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal cycles and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii) needles at diurnal and circannual scales. Using mRNA sequencing, we sampled 6.1 × 10 9 reads from 19 trees and constructed a de novo pan-transcriptome reference that includes 173,882 tree-derived transcripts. Using this reference, we mapped RNA-Seq reads from 179 samples that capture daily and annual variation. We identified 12,042 diurnally-cyclic transcripts, 9299 of which showed homology to annotated genes from other plant genomes, including angiosperm core clock genes. Annual analysis revealed 21,225 circannual transcripts, 17,335 of which showed homology to annotated genes from other plant genomes. The timing of maximum gene expression is associated with light intensity at diurnal scales and photoperiod at annual scales, with approximately half of transcripts reaching maximum expression +/- 2 h from sunrise and sunset, and +/- 20 days from winter and summer solstices. Comparisons with published studies from other conifers shows congruent behavior in clock genes with Japanese cedar (Cryptomeria), and a significant preservation of gene expression patterns for 2278 putative orthologs from Douglas-fir during the summer growing season, and 760 putative orthologs from spruce (Picea) during the transition from fall to winter. Our study highlight the extensive diurnal and circannual transcriptome variability demonstrated in conifer needles. At these temporal scales, 29% of expressed transcripts show a significant diurnal cycle, and 58.7% show a significant circannual cycle. Remarkably

  14. Arthropods and passerine birds in coniferous forest. The impact of acidification and needle-loss

    Energy Technology Data Exchange (ETDEWEB)

    Gunnarsson, B. [Goeteborg Univ., Dept. of Zoology, Sect. of Animal Ecology, Goeteborg (Sweden)

    1995-12-31

    The micro-habitat structure on coniferous trees changes as a result of needle-loss. This structural change in the vegetation may affect arthropods living in spruce Picea abies by indirect mechanisms, e.g. altered relations between prey and predators. The impact of acidification and needle-loss on some tree-living arthropods and passerine birds is reviewed. New information about the taxonomic composition of spiders in relation to needle density in a field experiments is reported. The main combined findings from the review and field experiments are: 1) Acid precipitation may be toxic because of high H{sup +} concentrations. However, simulated acid rain (pH 4.0) did not reduce the growth rate of a spruce-living spider. There is a present no evidence of toxic effect on arthropods at this level of pH. 2) Experiments in the field and laboratory and data from natural populations suggested that spruce-living arthropods are affected by the needle density of branches. These data showed a positive correlation between needle density and spider abundance. However, a large-scale field experiment could not confirm this relationship. 3) The interaction between bird predation and needle density was examined in a large-scale field experiment. There were strong negative effects of bird predation on arthropod abundance. Moreover, the taxonomic composition among spiders changed as a result of bird predation: raptorial spiders increased their relative abundance whereas sheetweb spiders decreased their relative abundance when bird predation was excluded. There were also some cases of bird predation/needle density interactions. In the absence of bird predation, the needle density affected the spider size distribution: large spiders were more common on needle-sparse branches than on needle-dens ones. The species composition was affected by similar interactions, e.g. bird predation effects on crab spiders (Thomisidae) were found on needle-sparse branches only. (Abstract Truncated)

  15. Practical guidelines for ultrasound-guided core needle biopsy of soft-tissue lesions: Transformation from beginner to specialist

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Yoon; Chung, Hye Won; Oh, Tack Sun; Lee, Jong Seok [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasound-guided core needle biopsy (US-CNB) is an important step in the diagnosis of musculoskeletal soft-tissue lesions. To maximize efficacy and minimize the complications of US-CNB, it is critical to collaborate with a multidisciplinary team and to understand the particular considerations of US-CNB for these lesions. The purpose of this article is to provide a systematic review and step-by-step tips for using US-CNB to diagnose musculoskeletal soft-tissue lesions.

  16. Influence of needle position on lumbar segmental nerve root block selectivity.

    Science.gov (United States)

    Wolff, André P; Groen, Gerbrand J; Wilder-Smith, Oliver H

    2006-01-01

    In patients with chronic low back pain radiating to the leg, segmental nerve root blocks (SNRBs) are performed to predict surgical outcome and identify the putative symptomatic spinal nerve. Epidural spread may lead to false interpretation, affecting clinical decision making. Systematic fluoroscopic analysis of epidural local anesthetic spread and its relationship to needle tip location has not been published to date. Study aims include assessment of epidural local anesthetic spread and its relationship to needle position during fluoroscopy-assisted blocks. Patients scheduled for L4, L5, and S1 blocks were included in this prospective observational study. Under fluoroscopy and electrostimulation, they received 0.5 mL of a mixture containing lidocaine 5 mg and iohexol 75 mg. X-rays with needle tip and contrast were scored for no epidural spread (grade 0), local spread epidurally (grade 1), or to adjacent nerve roots (grade 2). Sixty-five patients were analyzed for epidural spread, 62 for needle position. Grade 1 epidural spread occurred in 47% of L4 and 28% of L5 blocks and grade 2 spread in 3 blocks (5%; L5 n = 1, S1 n = 2). For lumbar blocks, the needle was most frequently found in the lateral upper half of the intervertebral foramen. Epidural spread occurred more frequently with medial needle positions (P = .06). The findings suggest (P = .06) that the risk of grade 1 and 2 lumbar epidural spread, which results in decreased SNRB selectivity, is greater with medial needle positions in the intervertebral foramen. The variability in anatomic position of the dorsal root ganglion necessitates electrostimulation to guide SNRB in addition to fluoroscopy.

  17. Study on Ballistic Absorbing Energy Character of High Performance Polyethylene Needle Felt

    Science.gov (United States)

    Kailiang, Zhu; Jianqiao, Fu

    2017-11-01

    The ballistic performance of polyethylene needle felt is tested and the failure morphology after test is also observed. The results showed that when the non-dimensionally non-stressed fibers in polyethylene needles are subjected to high-speed projectile, secondary movement such as stretching and twisting occurs first. This secondary movement is very full, it is the main way of ballistic absorbing energy of the polyethylene needle felt which can avoid the polyethylene fiber short-term rapid heating-up and destroyed. Analysis results show that under normal temperature and humidity conditions, the V50 of 6-layer forded polyethylene needle felt sample is 250m/s. At (450 ± 50) m/s speed range of the target missile, the mean value of the penetrative specific energy absorption for 3-layer forded polyethylene needle felt anti-1.1g simulated projectiles (tapered column) reaches 24.1J·m2/kg.

  18. A basic study on the development of deodorants using pine needle oil

    Energy Technology Data Exchange (ETDEWEB)

    Doh, K.S.; Lee, H.J. [Department of Chemical Engineering, Soongsil University, Seoul (Korea, Republic of); Kim, D.K. [Chemical Technology Division, Korea Research Institute of Chemical Technology, Taejon (Korea, Republic of)

    1997-11-01

    The basic study on the development of deodorant made from pine needle oil was performed. The pine needle oil(PNO) was analysed using GC, GC/MS and FT-1R analyzer for analysis of chemical concentration, chemical components and structure. The analysis results obtained from GC and GC/MS analyzer were composed to main components of {alpha},{beta}-Pinene(C{sub 10}H{sub 16}), 3-Carene (C{sub 10}H{sub 16}), {Upsilon}-terpinene(C{sub 10}H{sub 16}) and terpinolene(C{sub 10}H{sub 16}), etc. Also, the concentration of heavy metals analysed from AAS analyzer. The COD and BOD concentration of landfill leachate with pine needle oil were surveyed. As a results, the pine needle oil extracted from pine needles can be used to remove bad smells of wastes as a deodorant. (author). 13 refs., 3 figs., 3 tabs.

  19. Handling final storage of unreprocessed spent nuclear fuel

    International Nuclear Information System (INIS)

    1978-01-01

    The present second report from KBS describes how the safe final storage of spent unreprocessed nuclear fuel can be implemented. According to the Swedish Stipulation Law, the owner must specify in which form the waste is to be stored, how final storage is to be effected, how the waste is to be transported and all other aspects of fuel handling and storage which must be taken into consideration in judging whether the proposed final storage method can be considered to be absolutely safe and feasible. Thus, the description must go beyond general plans and sketches. The description is therefore relatively detailed, even concerning those parts which are less essential for evaluating the safety of the waste storage method. For those parts of the handling chain which are the same for both alternatives of the Stipulation Law, the reader is referred in some cases to the first report. Both of the alternatives of the Stipulation Law may be used in the future. Handling equipment and facilities for the two storage methods are so designed that a combination in the desired proportions is practically feasible. In this first part of the report are presented: premises and data, a description of the various steps of the handling procedure, a summary of dispersal processes and a safety analysis. (author)

  20. Comments on the variability of inherent bioelement contents of spruce needles

    International Nuclear Information System (INIS)

    Wyttenbach, A.; Tobler, L.; Bajo, S.

    1991-01-01

    Inherent needle contents are the relevant concentrations within the needle, excluding surface contaminations by aerosols. The error arising from the analysis of unwashed needles is quantified. For many elements it is the source of a large apparent variability. Spatial variability is discussed under the aspects of variability among trees within a plot and of variability among different plots. Both terms have implications as to the number of trees that should be sampled for the characterization of a plot. Variability with time is investigated by following the needle concentrations from an age of 1 to 23 months. The results give indications on favourable sampling dates and on the physiology of the different elements. All investigations refer to 20 elements, which have been determined by neutron activation analysis. (author) 6 figs., 5 tabs., 16 refs

  1. Enteral Feeding Set Handling Techniques.

    Science.gov (United States)

    Lyman, Beth; Williams, Maria; Sollazzo, Janet; Hayden, Ashley; Hensley, Pam; Dai, Hongying; Roberts, Cristine

    2017-04-01

    Enteral nutrition therapy is common practice in pediatric clinical settings. Often patients will receive a pump-assisted bolus feeding over 30 minutes several times per day using the same enteral feeding set (EFS). This study aims to determine the safest and most efficacious way to handle the EFS between feedings. Three EFS handling techniques were compared through simulation for bacterial growth, nursing time, and supply costs: (1) rinsing the EFS with sterile water after each feeding, (2) refrigerating the EFS between feedings, and (3) using a ready-to-hang (RTH) product maintained at room temperature. Cultures were obtained at baseline, hour 12, and hour 21 of the 24-hour cycle. A time-in-motion analysis was conducted and reported in average number of seconds to complete each procedure. Supply costs were inventoried for 1 month comparing the actual usage to our estimated usage. Of 1080 cultures obtained, the overall bacterial growth rate was 8.7%. The rinse and refrigeration techniques displayed similar bacterial growth (11.4% vs 10.3%, P = .63). The RTH technique displayed the least bacterial growth of any method (4.4%, P = .002). The time analysis in minutes showed the rinse method was the most time-consuming (44.8 ± 2.7) vs refrigeration (35.8 ± 2.6) and RTH (31.08 ± 0.6) ( P refrigerating the EFS between uses is the next most efficacious method for handling the EFS between bolus feeds.

  2. Disinfection of Dental Impressions Prior to Handling at Muhimbili ...

    African Journals Online (AJOL)

    All four dental technicians who handled the received impressions were interviewed. Questions asked were on practice and attitudes and responses were on different point scales. Results are based on information gathered from the dental technicians. Results: Of the 1,453 impressions received none were reported to have ...

  3. Needles and Other Sharps (Safe Disposal Outside of Health Care Settings)

    Science.gov (United States)

    ... disorders, and psoriasis. Examples of sharps include: Needles – hollow needles used to inject drugs (medication) under the ... and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1-888- ...

  4. Clinical observation of needle revision and 5-fluorouracil subconjunctive injection for the dysfunctional filtering blebs

    Directory of Open Access Journals (Sweden)

    Yan-Hua Gao

    2016-07-01

    Full Text Available AIM:To investigate the efficacy and safety of needle revision with 5-fluorouracil(5-FUon the dysfunctional filtering blebs after trabeculectomy and to assess the factors that may impact the success. METHODS:Eighty-three eyes in 76 patients underwent the needle revision and 5-FU subconjunctive injection for the dysfunctional blebs after trabeculectomy and were followed up for 12mo. The intraocular pressure(IOP, the number of drugs, corneal endothclium, bleb morphology and complications were observed and recorded. RESULTS:IOP decreased significantly from 35.3±5.8mmHg(1kPa=7.5mmHgof pre-needling to 17.0±4.3mmHg of post-needling(PPCI: 10.3-11.6. Statistically, there were no significant difference on needling effect with reference to the types of glaucoma, the use of mitomycin C(MMCduring the previous filtration surgery, the ages of patients, the intervals of needling operation from previous trabeculectomy, while there were significant difference on needling effect with reference to bleb appearance before needling, and the mean number of needling in patients that had surgery within 3mo were less than those who had surgery for more than 3mo. CONCLUSION: The needle revision combined with 5-FU is a safe, effective and simple method. Dysfunctional blebs should be treated early after trabeculectomy.

  5. Pelton turbine Needle erosion prediction based on 3D three- phase flow simulation

    International Nuclear Information System (INIS)

    Chongji, Z; Yexiang, X; Wei, Z; Yangyang, Y; Lei, C; Zhengwei, W

    2014-01-01

    Pelton turbine, which applied to the high water head and small flow rate, is widely used in the mountainous area. During the operation period the sediment contained in the water does not only induce the abrasion of the buckets, but also leads to the erosion at the nozzle which may damage the needle structure. The nozzle and needle structure are mainly used to form high quality cylindrical jet and increase the efficiency of energy exchange in the runner to the most. Thus the needle erosion will lead to the deformation of jet, and then may cause the efficiency loss and cavitation. The favourable prediction of abrasion characteristic of needle can effectively guide the optimization design and maintenance of needle structure. This paper simulated the unsteady three-dimensional multi-phase flow in the nozzle and injected jet flow. As the jet containing water and sediment is injected into the free atmosphere air with high velocity, the VOF model was adopted to predict the water and air flow. The sediment is simplified into round solid particle and the discrete particle model (DPM) was employed to predict the needle abrasion characteristic. The sand particle tracks were analyzed to interpret the mechanism of sand erosion on the needle surface. And the numerical result of needle abrasion was obtained and compared with the abrasion field observation. The similarity of abrasion pattern between the numerical results and field observation illustrated the validity of the 3D multi-phase flow simulation method

  6. Pelton turbine Needle erosion prediction based on 3D three- phase flow simulation

    Science.gov (United States)

    Chongji, Z.; Yexiang, X.; Wei, Z.; Yangyang, Y.; Lei, C.; Zhengwei, W.

    2014-03-01

    Pelton turbine, which applied to the high water head and small flow rate, is widely used in the mountainous area. During the operation period the sediment contained in the water does not only induce the abrasion of the buckets, but also leads to the erosion at the nozzle which may damage the needle structure. The nozzle and needle structure are mainly used to form high quality cylindrical jet and increase the efficiency of energy exchange in the runner to the most. Thus the needle erosion will lead to the deformation of jet, and then may cause the efficiency loss and cavitation. The favourable prediction of abrasion characteristic of needle can effectively guide the optimization design and maintenance of needle structure. This paper simulated the unsteady three-dimensional multi-phase flow in the nozzle and injected jet flow. As the jet containing water and sediment is injected into the free atmosphere air with high velocity, the VOF model was adopted to predict the water and air flow. The sediment is simplified into round solid particle and the discrete particle model (DPM) was employed to predict the needle abrasion characteristic. The sand particle tracks were analyzed to interpret the mechanism of sand erosion on the needle surface. And the numerical result of needle abrasion was obtained and compared with the abrasion field observation. The similarity of abrasion pattern between the numerical results and field observation illustrated the validity of the 3D multi-phase flow simulation method.

  7. Recommendations for Collection and Handling of Specimens From Group Breast Cancer Clinical Trials

    Science.gov (United States)

    Leyland-Jones, Brian R.; Ambrosone, Christine B.; Bartlett, John; Ellis, Matthew J.C.; Enos, Rebecca A.; Raji, Adekunle; Pins, Michael R.; Zujewski, Jo Anne; Hewitt, Stephen M.; Forbes, John F.; Abramovitz, Mark; Braga, Sofia; Cardoso, Fatima; Harbeck, Nadia; Denkert, Carsten; Jewell, Scott D.

    2008-01-01

    Recommendations for specimen collection and handling have been developed for adoption across breast cancer clinical trials conducted by the Breast International Group (BIG)-sponsored Groups and the National Cancer Institute (NCI)-sponsored North American Cooperative Groups. These recommendations are meant to promote identifiable standards for specimen collection and handling within and across breast cancer trials, such that the variability in collection/handling practices that currently exists is minimized and specimen condition and quality are enhanced, thereby maximizing results from specimen-based diagnostic testing and research. Three working groups were formed from the Cooperative Group Banking Committee, BIG groups, and North American breast cancer cooperative groups to identify standards for collection and handling of (1) formalin-fixed, paraffin-embedded (FFPE) tissue; (2) blood and its components; and (3) fresh/frozen tissue from breast cancer trials. The working groups collected standard operating procedures from multiple group specimen banks, administered a survey on banking practices to those banks, and engaged in a series of discussions from 2005 to 2007. Their contributions were synthesized into this document, which focuses primarily on collection and handling of specimens to the point of shipment to the central bank, although also offers some guidance to central banks. Major recommendations include submission of an FFPE block, whole blood, and serial serum or plasma from breast cancer clinical trials, and use of one fixative and buffer type (10% neutral phosphate-buffered formalin, pH 7) for FFPE tissue across trials. Recommendations for proper handling and shipping were developed for blood, serum, plasma, FFPE, and fresh/frozen tissue. PMID:18955459

  8. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  9. A data-driven soft sensor for needle deflection in heterogeneous tissue using just-in-time modelling.

    Science.gov (United States)

    Rossa, Carlos; Lehmann, Thomas; Sloboda, Ronald; Usmani, Nawaid; Tavakoli, Mahdi

    2017-08-01

    Global modelling has traditionally been the approach taken to estimate needle deflection in soft tissue. In this paper, we propose a new method based on local data-driven modelling of needle deflection. External measurement of needle-tissue interactions is collected from several insertions in ex vivo tissue to form a cloud of data. Inputs to the system are the needle insertion depth, axial rotations, and the forces and torques measured at the needle base by a force sensor. When a new insertion is performed, the just-in-time learning method estimates the model outputs given the current inputs to the needle-tissue system and the historical database. The query is compared to every observation in the database and is given weights according to some similarity criteria. Only a subset of historical data that is most relevant to the query is selected and a local linear model is fit to the selected points to estimate the query output. The model outputs the 3D deflection of the needle tip and the needle insertion force. The proposed approach is validated in ex vivo multilayered biological tissue in different needle insertion scenarios. Experimental results in five different case studies indicate an accuracy in predicting needle deflection of 0.81 and 1.24 mm in the horizontal and vertical lanes, respectively, and an accuracy of 0.5 N in predicting the needle insertion force over 216 needle insertions.

  10. Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers.

    Science.gov (United States)

    Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György

    2009-08-01

    Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers

  11. Endoscopic treatment for pancreatic diseases: Needle-knife-guided cannulation via the minor papilla.

    Science.gov (United States)

    Wang, Wei; Gong, Biao; Jiang, Wei-Song; Liu, Lei; Bielike, Kouken; Xv, Bin; Wu, Yun-Lin

    2015-05-21

    To determine the efficacy and safety of meticulous cannulation by needle-knife. Three needle-knife procedures were used to facilitate cannulation in cases when standard cannulation techniques failed. A total of 104 cannulations via the minor papilla attempted in 74 patients at our center between January 2008 and June 2014 were retrospectively reviewed. Standard methods were successful in 79 cannulations. Of the 25 cannulations that could not be performed by standard methods, 19 were performed by needle-knife, while 17 (89.5%) were successful. Needle-knife use improved the success rate of cannulation [76.0%, 79/104 vs 92.3%, (79 + 17)/104; P = 0.001]. When the 6 cases not appropriate for needle-knife cannulation were excluded, the success rate was improved further (80.6%, 79/98 vs 98.0%, 96/98; P = 0.000). There were no significant differences in the rates of post-endoscopic retrograde cholangiopancreatography adverse events between the group using standard methods alone and the group using needle-knife after failure of standard methods (4.7% vs 10.5%, P = 0.301). The needle-knife procedure may be an alternative method for improving the success rate of cannulation via the minor papilla, particularly when standard cannulation has failed.

  12. Anatomical practices of preserving, handling and management of ...

    African Journals Online (AJOL)

    Deaths resulting from disasters as well as some unwholesome practices are major factors that affect the quality of practices. Yet, the management of human remains requires utmost attention for the purpose of health, ethics and environment. Outbreaks of diseases and the spread of such, for instance, the case of Ebola virus, ...

  13. Dry needling and exercise for chronic whiplash - a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Souvlis Tina

    2009-12-01

    Full Text Available Abstract Background Chronic whiplash is a common and costly problem. Sensory hypersensitivity is a feature of chronic whiplash that is associated with poor responsiveness to physical treatments such as exercise. Modalities such as dry-needling have shown some capacity to modulate sensory hypersensitivity, suggesting that when combined with advice and exercise, such an approach may be more effective in the management of chronic whiplash. The primary aim of this project is to investigate the effectiveness of dry-needling, advice and exercise for chronic whiplash. Method/Design A double-blind randomised controlled trial will be conducted. 120 participants with chronic whiplash, grade II will be randomised to receive either 1 dry-needling, advice and exercise or 2 sham dry-needling, advice and exercise. All participants will receive an educational booklet on whiplash. Participants who are randomised to Group 1 will receive 6 treatments of combined dry-needling and exercise delivered in the first 3 weeks of the 6 week program, and 4 treatments of exercise only in the last 3 weeks of the program. Participants randomised to Group 2 will receive an identical protocol, except that a sham dry-needling technique will be used instead of dry-needling. The primary outcome measures are the Neck Disability Index (NDI and participants' perceived recovery. Outcomes will be measured at 6, 12, 24 and 52 weeks after randomization by an assessor who is blind to the group allocation of the participants. In parallel, an economic analysis will be conducted. Discussion This trial will utilise high quality trial methodologies in accordance with CONSORT guidelines. The successful completion of this trial will provide evidence of the effectiveness and cost-effectiveness of a combined treatment approach for the management of chronic whiplash. Trial registration ACTRN12609000470291

  14. MAINTENANCE PLANNING OF THE SEWING NEEDLES OF SIMPLE SEWING MACHINES

    Directory of Open Access Journals (Sweden)

    ŞUTEU Marius Darius

    2017-05-01

    Full Text Available The effectiveness of simple sewing machines can be increased through the planning of predictive maintenance activities. The monitoring of the technical condition of the sewing needles of simple sewing machines was based on the measurement of their noise level. For this purpose a Center 322 sonometer was used, while the data obtained during the monitoring process was analyzed through the E322 software. The working speed of the simple sewing machine that was used for obtaining the experimental results varied from 200 stitches/minute to 4000 stitches/minute. The noise levels of a new needle at the working speed of 200 stitches/minute and 4000 stitches/minute were measured. The noise levels for a fault needle at the same working speed of 200 stitches/minute, respectively 4000 stitches/minute were also measured. Using Fuzzy Logic Toolbox ™ module of Matlab®, a decision-making system for determining when replacement of the sewing needles of simple sewing machines should be performed was developed. A case study illustrates the employment of the decision-making system based on fuzzy logic for a simple sewing machine. By replacing the sewing needles of simple sewing machines at the time specified through the decision-making system based on fuzzy logic, the occurrence of the failure can be prevented and the quality of textile products can be improved.

  15. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation.

    Science.gov (United States)

    Limmer, Alexandra M; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  16. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    Directory of Open Access Journals (Sweden)

    Alexandra M. Limmer

    2017-01-01

    Full Text Available Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient’s caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  17. Clinical application of percutaneous needling lung abscess drairnage under CT guidance

    International Nuclear Information System (INIS)

    Hu Xiaokun; Wang Mingyou; Li Chenjun; Lv Dongfang; Li Xiaodong; Yu Zhaocun

    2004-01-01

    Objective: To discuss the clinical application of drainage for lung abscess by needle puncture under CT guidance. Methods: 18 cases of lung abscess were drainaged by needle puncture under CT guidance, including direct aspiration by puncture needle 1-3 times (n=8) and retaining drainage tube continuously (n=10). Results: 17 cases with this procedure were succeeded possessing success rate of 94.7%(17/18). The patients were followed up for 11-35 days with symptom relieving better obviously and the focus shrinkage or disappeared (n=16), the curative rate reached 88.9%(16/18). The main complication was pneumothorax with capacities of 30%(n=1). Conclusions: The curative course of lung abscess can be shortened greatly by percutaneous needling drainage under CT guidance with mild trauma. The procedure is simple with high successful rate and less complication. (authors)

  18. Dynamics of Pinus sylvestris L. needles activity in Predbaikal’ye forests

    Directory of Open Access Journals (Sweden)

    I.M. Romanova

    2013-11-01

    Full Text Available The study was aimed to analyse changes in peroxidase activity of common pine needles throughout the year. The needles of the 1-st, 2-nd and 3-d years were collected. Total activity of guaiacol-dependent peroxidase was determined. Minimum peroxidase activity is observed in January and February. In March intense overall activation of peroxidase is observed in the needles of all ages, which might be related to spring enhancement of physiological processes and activation of metabolism. Autumn period is characterized by more or less high activities of guaiacol peroxidase from September till November, which is related to its participation in stress-adaptation to low temperatures in winter. Peroxidase activity changes depending on the season of the year. Needles of different age are characterized by their own peroxidase activity level in various time periods.

  19. A novel technique of rotator cuff repair using spinal needle and suture loop

    Directory of Open Access Journals (Sweden)

    Muzaffar Nasir

    2010-11-01

    Full Text Available Abstract Background We present a simple technique of arthroscopic rotator cuff repair using a spinal needle and suture loop. Methods With the arthroscope laterally, a spinal needle looped with PDS is inserted percutaneously into the shoulder posteriorly and penetrated through the healthy posterior cuff tear margin. Anteriorly, another spinal needle loaded with PDS is inserted percutaneously to engage the healthy tissue at the anterior tear margin. The suture in the anterior needle is then delivered into the suture loop of the posterior needle using a suture retriever. The posterior needle and loop are then pulled out carrying the anterior suture with it. The two limbs of this suture are then retrieved through a cannula for knotting. The same procedure is then repeated for additional suturing. Suture anchors placed over the greater tuberosity are used to complete the repair. Conclusion This is an easy method of rotator cuff repair using simple instruments and lesser time, hence can be employed at centers with less equipment and at reduced cost to the patient.

  20. Self-reported injection practices among people who use drugs in French prisons: Public health implications (ANRS-Coquelicot survey 2011-2013).

    Science.gov (United States)

    Michel, Laurent; Trouiller, Philippe; Chollet, Aude; Molinier, Marie; Duchesne, Lucie; Jauffret-Roustide, Marie

    2018-04-01

    The aims of this study were to describe the prevalences of injection practices and needle/syringe sharing in people who use drugs in French prisons, and to investigate associated factors. Using the ANRS-Coquelicot survey (2011-2013), a random sample of 1718 people who used drugs in free society was included. Information regarding a history of incarceration, drug-injection practices inside prison and needle/syringe sharing was collected during interviews. In our sample, 65.5% reported a history of injection and 57.4% had been incarcerated at least once. Among those who reported both of these conditions, 14% reported injection practices inside prison, 40.5% of whom had shared needles/syringes. In the multivariable model, the following variables were associated with injection practices inside prison: being a Russian-speaking detainee, having spent more time in prison, and having started to inject before 1996 and especially before 1987. Being Russian speaking was also associated with needle/syringe sharing in prison. The prevalences of injection practices and needle/syringe sharing in prisons are alarmingly high. Effective interventions to prevent the transmission of infectious diseases among people who use drugs in the prison setting are essential. The implementation of international recommendations on the principle of equivalence between prisons and the community is still very limited in most countries, and should be complemented with tailored interventions for the most vulnerable prison populations, especially Russian-speaking detainees. © 2017 Australasian Professional Society on Alcohol and other Drugs.

  1. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes.

    Science.gov (United States)

    Præstmark, Kezia A; Jensen, Morten L; Madsen, Nils B; Kildegaard, Jonas; Stallknecht, Bente M

    2016-01-01

    Pen needles used for subcutaneous injections have gradually become shorter, thinner and more thin walled, and thereby less robust to patient reuse. Thus, different needle sizes, alternative tip designs and needles resembling reuse were tested to explore how needle design influences ease of insertion, pain and skin trauma. 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m 2 were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. Needle diameter was positively related to PF and SBP (ptrend relation. Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome was dependent of SBP increase. The shape and design of a needle and the needle tip affect ease of insertion, pain and skin trauma. Relations are seen across different data acquisition methods and across species, enabling needle performance testing outside of clinical trials. NCT02531776; results.

  2. Target motion predictions for pre-operative planning during needle-based interventions

    NARCIS (Netherlands)

    op den Buijs, J.; Abayazid, Momen; de Korte, Chris L.; Misra, Sarthak

    During biopsies, breast tissue is subjected to displacement upon needle indentation, puncture, and penetration. Thus, accurate needle placement requires pre-operative predictions of the target motions. In this paper, we used ultrasound elastography measurements to non-invasively predict elastic

  3. The common structural architecture of Shigella flexneri and Salmonella typhimurium type three secretion needles.

    Directory of Open Access Journals (Sweden)

    Jean-Philippe Demers

    2013-03-01

    Full Text Available The Type Three Secretion System (T3SS, or injectisome, is a macromolecular infection machinery present in many pathogenic Gram-negative bacteria. It consists of a basal body, anchored in both bacterial membranes, and a hollow needle through which effector proteins are delivered into the target host cell. Two different architectures of the T3SS needle have been previously proposed. First, an atomic model of the Salmonella typhimurium needle was generated from solid-state NMR data. The needle subunit protein, PrgI, comprises a rigid-extended N-terminal segment and a helix-loop-helix motif with the N-terminus located on the outside face of the needle. Second, a model of the Shigella flexneri needle was generated from a high-resolution 7.7-Å cryo-electron microscopy density map. The subunit protein, MxiH, contains an N-terminal α-helix, a loop, another α-helix, a 14-residue-long β-hairpin (Q51-Q64 and a C-terminal α-helix, with the N-terminus facing inward to the lumen of the needle. In the current study, we carried out solid-state NMR measurements of wild-type Shigella flexneri needles polymerized in vitro and identified the following secondary structure elements for MxiH: a rigid-extended N-terminal segment (S2-T11, an α-helix (L12-A38, a loop (E39-P44 and a C-terminal α-helix (Q45-R83. Using immunogold labeling in vitro and in vivo on functional needles, we located the N-terminus of MxiH subunits on the exterior of the assembly, consistent with evolutionary sequence conservation patterns and mutagenesis data. We generated a homology model of Shigella flexneri needles compatible with both experimental data: the MxiH solid-state NMR chemical shifts and the state-of-the-art cryoEM density map. These results corroborate the solid-state NMR structure previously solved for Salmonella typhimurium PrgI needles and establish that Shigella flexneri and Salmonella typhimurium subunit proteins adopt a conserved structure and orientation in their

  4. Handling of UF6 in U.S. gaseous diffusion plants

    International Nuclear Information System (INIS)

    Legeay, A.J.

    1978-01-01

    A comprehensive systems analysis of UF 6 handling has been made in the three U.S. gaseous diffusion plants and has resulted in a significant impact on the equipment design and the operating procedures of these facilities. The equipment, facilities, and industrial practices in UF 6 handling operations as they existed in the early 1970's are reviewed with particular emphasis placed on the changes which have been implemented. The changes were applied to the systems and operating methods which evolved from the design, startup, and operation of the Oak Ridge Gaseous Diffusion Plant in 1945

  5. Better fuel handling system performance through improved elastomers and seals

    Energy Technology Data Exchange (ETDEWEB)

    Wensel, R G; Metcalfe, R [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1997-12-31

    In the area of elastomers, tests have identified specific compounds that perform well in each class of CANDU service. They offer gains in service life, sometimes by factors of ten or more. Moreover, the aging characteristics of these specific compounds are being thoroughly investigated, whereas many elastomers used previously were either non-specific or their aging was unknown. In this paper the benefits of elastomer upgrading, as well as the deficiencies of current station elastomer practices, are discussed in the context of fuel handling equipment. Guidelines for procurement, storage, handling and condition monitoring of elastomer seals are outlined. (author). 3 figs.

  6. Better fuel handling system performance through improved elastomers and seals

    International Nuclear Information System (INIS)

    Wensel, R.G.; Metcalfe, R.

    1996-01-01

    In the area of elastomers, tests have identified specific compounds that perform well in each class of CANDU service. They offer gains in service life, sometimes by factors of ten or more. Moreover, the aging characteristics of these specific compounds are being thoroughly investigated, whereas many elastomers used previously were either non-specific or their aging was unknown. In this paper the benefits of elastomer upgrading, as well as the deficiencies of current station elastomer practices, are discussed in the context of fuel handling equipment. Guidelines for procurement, storage, handling and condition monitoring of elastomer seals are outlined. (author). 3 figs

  7. WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

    International Nuclear Information System (INIS)

    Gorman, A; Seabrook, G; Brakken, A; Dubois, M; Marn, C; Wilson, C; Jacobson, D; Liu, Y

    2015-01-01

    Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles

  8. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    Science.gov (United States)

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  9. Use of a Puncture Needle for Recanalization of an Occluded Right Subclavian Vein

    International Nuclear Information System (INIS)

    Gupta, Himanshu; Murphy, Timothy P.; Soares, Gregory M.

    1998-01-01

    We report a patient in whom we used a puncture needle to initiate percutaneous recanalization of a chronic occlusion of the junction between the right subclavian vein and the right brachiocephalic vein. Under fluoroscopic guidance, an 18-gauge needle was used to puncture the right subclavian vein. When contrast material injected through the needle confirmed intravascular location, the needle was advanced until it deflected and perforated an occlusion balloon target positioned within the right brachiocephalic vein. This technique may be useful in patients with central venous occlusions that are refractory to traversal using traditional catheter and guidewire techniques

  10. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety

    Directory of Open Access Journals (Sweden)

    Fujii C

    2013-07-01

    Full Text Available Chieko FujiiFaculty of Nursing and Medical Care, Keio University, Kanagawa, JapanBackground: Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures.Methods: Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined.Results: Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed.Conclusion: This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.Keywords: blood collection, nerve damage, motion analysis, patient safety, puncture angle, clinical education

  11. Detection of needle to nerve contact based on electric bioimpedance and machine learning methods.

    Science.gov (United States)

    Kalvoy, Havard; Tronstad, Christian; Ullensvang, Kyrre; Steinfeldt, Thorsten; Sauter, Axel R

    2017-07-01

    In an ongoing project for electrical impedance-based needle guidance we have previously showed in an animal model that intraneural needle positions can be detected with bioimpedance measurement. To enhance the power of this method we in this study have investigated whether an early detection of the needle only touching the nerve also is feasible. Measurement of complex impedance during needle to nerve contact was compared with needle positions in surrounding tissues in a volunteer study on 32 subjects. Classification analysis using Support-Vector Machines demonstrated that discrimination is possible, but that the sensitivity and specificity for the nerve touch algorithm not is at the same level of performance as for intra-neuralintraneural detection.

  12. 7 CFR 205.201 - Organic production and handling system plan.

    Science.gov (United States)

    2010-01-01

    ... MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED... or handling operation, except as exempt or excluded under § 205.101, intending to sell, label, or... implemented to comply with the requirements established in § 205.103; (5) A description of the management...

  13. Effect of dietary mugwort ( Artemisia vulgaris L.) and pine needle ...

    African Journals Online (AJOL)

    The effects of dietary mugwort and pine needle powder supplementation on growth performance, serum cholesterol, and meat quality of broilers were evaluated in a 35 days feed trial. 200 one day old broilers were randomly allocated to five dietary treatments (0, 1 and 2% mugwort or 1 and 2% pine needle powder) with ...

  14. Carbon fibre and nitinol needles for MRI-guided interventions: First in vitro and in vivo application

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Christoph, E-mail: Christoph.thomas@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Wojtczyk, Hanne [Section of Experimental Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Rempp, Hansjoerg; Clasen, Stephan; Horger, Marius [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Lassberg, Christoph von [Department of Sports Medicine, University of Tuebingen, Silcherstrasse 5, 72076 Tuebingen (Germany); Fritz, Jan [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 600 North Wolfe Street, Baltimore, MD 21287 (United States); Claussen, Claus D. [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Pereira, Philippe L. [Department of Radiology, Minimally Invasive Therapies and Nuclearmedicine, SLK-Kliniken Heilbronn GmbH, Am Gesundbrunnen 20-26, 74078 Heilbronn (Germany)

    2011-09-15

    Objective: To assess the artefact properties of a MR-compatible carbon fibre needle with a nitinol mandrin in vitro and to report first clinical experiences. Materials and methods: In vitro, the carbon fibre/nitinol needle was imaged at different angles against the main magnetic field (1.5 T open bore magnet). A gradient echo MR fluoroscopy sequence (GRE: TR 9.3 ms, TE 3.12 ms, bandwidth 200 Hz/pixel, flip-angle 12{sup o}) and a fast turbo spin echo sequence (FSE: TR 412 ms, TE 9.7 ms, bandwidth 200 Hz/pixel, flip-angle 150{sup o}) were used. Artefact width, needle intensity contrast and needle tip location errors were assessed. In vivo, lumbar periradicular corticosteroid injections and one sclerotherapy were performed with carbon fibre needles (10 procedures) and with titanium alloy needles (2 procedures). The artefact sizes and contrasts were measured. Results: In vitro, artefact diameters of the carbon fibre needle ranged from 3.3 to 4.6 mm, contrasts from 0.11 to 0.52, with larger artefact contrasts and widths with the GRE sequence. Needle tip location errors of -2.1 to -2.8 mm were observed. Decreasing angles to the main field lead to smaller artefacts. In vivo, the carbon fibre/nitinol needle produced smaller artefacts (mean width FSE/GRE: 2.8 mm/4.6 mm) with lower contrast (0.30-0.42) than the titanium alloy needle (mean width FSE/GRE: 4.1 mm/7.5 mm, contrast 0.60-0.73). Conclusions: The carbon fibre/nitinol needle is useful for performing MR-guided interventions at 1.5 T, producing more subtle artefacts than a titanium alloy needle, but with an incomplete depiction and thus inaccurate localization of the needle tip.

  15. Flexible Electrostatic Technologies for Capture and Handling, Phase 1

    Science.gov (United States)

    Bryan, Thomas

    2015-01-01

    Fundamental to many of NASA's in-space transportation missions is the capture and handling of various objects and vehicles in various orbits for servicing, debris disposal, sample retrieval, and assembly without the benefit of sufficient grapple fixtures and docking ports. To perform similar material handling tasks on Earth, pincher grippers, suction grippers, or magnetic chucks are used, but are unable to reliably grip aluminum and composite spacecraft, insulation, radiators, solar arrays, or extra-terrestrial objects in the vacuum of outer space without dedicated handles in the right places. The electronic Flexible Electrostatic Technologies for space Capture and Handling (FETCH) will enable reliable and compliant gripping (soft dock) of practically any object in various orbits or surfaces without dedicated mechanical features, very low impact capture, and built-in proximity sensing without any conventional actuators. Originally developed to handle semiconductor and glass wafers during vacuum chamber processing without contamination, the normal rigid wafer handling chucks are replaced with thin metal foil segments laminated in flexible insulation driven by commercial off-the-shelf solid state, high-voltage power supplies. Preliminary testing in NASA Marshall Space Flight Center's (MSFC's) Flat Floor Robotics Lab demonstrated compliant alignment and gripping with a full-sized, 150-lb microsat mockup and translation before a clean release with a flip of a switch. The flexible electrostatic gripper pads can be adapted to various space applications with different sizes, shapes, and foil electrode layouts even with openings through the gripper pads for addition of guidance sensors or injection of permanent adhesives. With gripping forces estimated between 0.5 and 2.5 lb/in2 or 70-300 lb/ft2 of surface contact, the FETCH can turn on and off rapidly and repeatedly to enable sample handling, soft docking, in-space assembly, precision relocation, and surface translation

  16. SIMULATION OF DRIVER’S LOCOMOTIVE-HANDLING ACTIVITY USING THE THEORY OF FUZZY GRAPHS

    Directory of Open Access Journals (Sweden)

    T. V. Butko

    2015-03-01

    Full Text Available Purpose. The efficiency and safety of locomotive control improving is important and relevant scientific and practical problem. Every driver during the trains-handling bases on his experience and knowledge, that is why the compilation and detection the most efficient ways to control the locomotive-handling is one of the stages of measures development to reduce transportation costs. The purpose of this paper is a formalization process description of locomotive-handling and quality parameters determination of this process. Methodology. In order to achieve this goal the theory of fuzzy probabilistic graphs was used. Vertices of the graph correspond to the events start and end operations at train-handling. The graph arcs describe operations on train-handling. Graph consists of thirteen peaks corresponding to the main control actions of the engine-driver. The weighting factors of transitions between vertices are assigned by fuzzy numbers. Their values were obtained by expert estimates. Fuzzy probabilities and transition time are presented as numbers with trapezoidal membership function. Findings. Using successive merging of parallel arcs, loops and vertices elimination, the equivalent fuzzy graph of train-handling and the corresponding L-matrix were obtained. Equivalent graph takes into account separately activity of the driver during normal operation and during emergency situations. Originality. The theoretical foundations of describing process formalization in driver’s locomotive-handling activity were developed using the fuzzy probabilistic graph. The parameters characterizing the decision-making process of engineer were obtained. Practical value. With the resulting model it is possible to estimate the available reserves for the quality improvement of locomotive-handling. Reduction in the time for decision-making will lead to the approximation the current mode of control to the rational one and decrease costs of hauling operations. And reduction

  17. Force-Sensor-Based Estimation of Needle Tip Deflection in Brachytherapy

    Directory of Open Access Journals (Sweden)

    Thomas Lehmann

    2013-01-01

    in real time during needle insertion is the main contribution of this paper. The proposed approach solely relies on the measured forces and torques without a need for any other invasive/noninvasive sensing devices. A few mechanical models have been introduced previously regarding the way the forces are composed along the needle during insertion; we will compare our model to those approaches in terms of accuracy. In order to conduct experiments to verify the deflection model, a custom-built, 2-DOF robotic system for needle insertion is developed and discussed. This system is a prototype of an intelligent, hand-held surgical assistant tool that incorporates the virtual sensor proposed in this paper.

  18. A plasma needle generates nitric oxide

    International Nuclear Information System (INIS)

    Stoffels, E; Gonzalvo, Y Aranda; Whitmore, T D; Seymour, D L; Rees, J A

    2006-01-01

    Generation of nitric oxide (NO) by a plasma needle is studied by means of mass spectrometry. The plasma needle is an atmospheric glow generated by a radio-frequency excitation in a mixture of helium and air. This source is used for the treatment of living tissues, and nitric oxide may be one of the most important active agents in plasma therapy. Efficient NO generation is of particular importance in the treatment of cardiovascular diseases. Mass spectrometric measurements have been performed under various plasma conditions; gas composition in the plasma and conversion of feed gases (nitrogen and oxygen) into other species has been studied. Up to 30% of the N 2 and O 2 input is consumed in the discharge, and NO has been identified as the main conversion product

  19. Real-time image-based B-mode ultrasound image simulation of needles using tensor-product interpolation.

    Science.gov (United States)

    Zhu, Mengchen; Salcudean, Septimiu E

    2011-07-01

    In this paper, we propose an interpolation-based method for simulating rigid needles in B-mode ultrasound images in real time. We parameterize the needle B-mode image as a function of needle position and orientation. We collect needle images under various spatial configurations in a water-tank using a needle guidance robot. Then we use multidimensional tensor-product interpolation to simulate images of needles with arbitrary poses and positions using collected images. After further processing, the interpolated needle and seed images are superimposed on top of phantom or tissue image backgrounds. The similarity between the simulated and the real images is measured using a correlation metric. A comparison is also performed with in vivo images obtained during prostate brachytherapy. Our results, carried out for both the convex (transverse plane) and linear (sagittal/para-sagittal plane) arrays of a trans-rectal transducer indicate that our interpolation method produces good results while requiring modest computing resources. The needle simulation method we present can be extended to the simulation of ultrasound images of other wire-like objects. In particular, we have shown that the proposed approach can be used to simulate brachytherapy seeds.

  20. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  1. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  2. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    Directory of Open Access Journals (Sweden)

    Carla Treloar

    Full Text Available A formal Needle and Syringe Program (NSP is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV risk and risk mitigation opportunities for inmates.The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons.A needle/syringe was nominated as being typically priced in the 'inside' prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment "quiet", stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison.The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices.

  3. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    Science.gov (United States)

    Treloar, Carla; McCredie, Luke; Lloyd, Andrew R

    2016-01-01

    A formal Needle and Syringe Program (NSP) is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV) risk and risk mitigation opportunities for inmates. The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons. A needle/syringe was nominated as being typically priced in the 'inside' prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison) and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment) "quiet", stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison. The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices.

  4. [Effects of warm needling moxibustion on knee cartilage and morphology in rats with knee osteoarthritis].

    Science.gov (United States)

    Zhang, Yongliang; Mi, Yiqun; Gang, Jiahong; Wang, Huamin

    2016-02-01

    To observe the effects of warm needling moxibustion on body mass, knee cartilage andmorphology in rats with knee osteoarthritis (KOA). Forty SD rats were randomly divided into a normalgroup, a model group, a medication group and a warm needling group, 10 rats in each one. Except the normalgroup, the rats in the remaining three groups were injected with papain to establish the model of KOA. After themodeling, rats in the model group did not receive any treatment; rats in the warm needling group were treated withwarm needling moxibustion at bilateral "Xiqian"; rats in the medication group were treated with intragastric administration of meloxicam; rats in the normal group were treated with 0. 9% NaCl solution (identical dose as medication group) and immobilized as the warm needling group. The treatment was given once a day for consecutive20 days. The body mass, scale of knee cartilage and morphological changes were observed in each group after'treatment. The increasing of body mass in the medication group and warm needling group was faster than!that in the model group, but slower than that in the normal group (all Pwarm needling group was not statistically significant (P>0. 05). The scale of knee cartilage in thewarm needling group and medication group was significantly lower than that in the model group (both Pwarm needling group was lower than that in the medication group (Pwarm needlinggroup were superior to those in the medication group. The warm needling moxibustion could effectively reduce the knee pain, improve the recovery of knee cartilage, which is a safe and effective treatment.

  5. Molecular model of a type III secretion system needle: Implications for host-cell sensing.

    Science.gov (United States)

    Deane, Janet E; Roversi, Pietro; Cordes, Frank S; Johnson, Steven; Kenjale, Roma; Daniell, Sarah; Booy, Frank; Picking, William D; Picking, Wendy L; Blocker, Ariel J; Lea, Susan M

    2006-08-15

    Type III secretion systems are essential virulence determinants for many Gram-negative bacterial pathogens. The type III secretion system consists of cytoplasmic, transmembrane, and extracellular domains. The extracellular domain is a hollow needle protruding above the bacterial surface and is held within a basal body that traverses both bacterial membranes. Effector proteins are translocated, via this external needle, directly into host cells, where they subvert normal cell functions to aid infection. Physical contact with host cells initiates secretion and leads to formation of a pore, thought to be contiguous with the needle channel, in the host-cell membrane. Here, we report the crystal structure of the Shigella flexneri needle subunit MxiH and a complete model for the needle assembly built into our three-dimensional EM reconstruction. The model, combined with mutagenesis data, reveals that signaling of host-cell contact is relayed through the needle via intersubunit contacts and suggests a mode of binding for a tip complex.

  6. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  7. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    Science.gov (United States)

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416

  8. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  9. Image Analytical Approach for Needle-Shaped Crystal Counting and Length Estimation

    DEFF Research Database (Denmark)

    Wu, Jian X.; Kucheryavskiy, Sergey V.; Jensen, Linda G.

    2015-01-01

    Estimation of nucleation and crystal growth rates from microscopic information is of critical importance. This can be an especially challenging task if needle growth of crystals is observed. To address this challenge, an image analytical method for counting of needle-shaped crystals and estimating...

  10. Pinus nigra and Pinus pinaster needles as passive samplers of polycyclic aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Piccardo, Maria Teresa; Pala, Mauro; Bonaccurso, Bruna; Stella, Anna; Redaelli, Anna; Paola, Gaudenzio; Valerio, Federico

    2005-01-01

    Nine polycyclic aromatic hydrocarbons (PAHs) were analysed in pine needles of different ages (from 6 to 30 months) collected from two species, Pinus nigra and Pinus pinaster, in seven sites located along a transect from a suburban to a rural area of Genoa (Italy). In all sites and for both species, concentrations of more volatile PAHs (phenanthrene, anthracene, fluoranthene, pyrene) were higher than those for other less volatile PAHs, which are preferentially sorbed to airborne particulates (benzo[a]anthracene, chrysene, benzofluoranthenes, benzo[a]pyrene). Concentrations of total PAHs found in P. nigra in the rural sites were, on the average, 2.3 times higher than those in P. pinaster growing nearby. In both pine species, concentrations of volatile PAHs increased according to needle age. Annual trends of other PAHs were more variable, with a general decrease in older needles. P. pinaster needles are shown to be more reliable passive samplers, since they are more resistant to plant diseases, and considerable variation in PAH concentration was observed in P. nigra needles with moulds and fungi. - The suitability of the pine needles as passive air samplers for persistent trace organics is demonstrated

  11. Pinus nigra and Pinus pinaster needles as passive samplers of polycyclic aromatic hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Piccardo, Maria Teresa [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy)]. E-mail: chimamb@istge.it; Pala, Mauro [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Bonaccurso, Bruna [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Stella, Anna [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Redaelli, Anna [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Paola, Gaudenzio [Botany Department, Genoa University, C.so Dogali 1 canc., 16136 Genova (Italy); Valerio, Federico [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy)

    2005-01-01

    Nine polycyclic aromatic hydrocarbons (PAHs) were analysed in pine needles of different ages (from 6 to 30 months) collected from two species, Pinus nigra and Pinus pinaster, in seven sites located along a transect from a suburban to a rural area of Genoa (Italy). In all sites and for both species, concentrations of more volatile PAHs (phenanthrene, anthracene, fluoranthene, pyrene) were higher than those for other less volatile PAHs, which are preferentially sorbed to airborne particulates (benzo[a]anthracene, chrysene, benzofluoranthenes, benzo[a]pyrene). Concentrations of total PAHs found in P. nigra in the rural sites were, on the average, 2.3 times higher than those in P. pinaster growing nearby. In both pine species, concentrations of volatile PAHs increased according to needle age. Annual trends of other PAHs were more variable, with a general decrease in older needles. P. pinaster needles are shown to be more reliable passive samplers, since they are more resistant to plant diseases, and considerable variation in PAH concentration was observed in P. nigra needles with moulds and fungi. - The suitability of the pine needles as passive air samplers for persistent trace organics is demonstrated.

  12. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    Science.gov (United States)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  13. Characterization of ultrasound elevation beamwidth artifacts for prostate brachytherapy needle insertion

    International Nuclear Information System (INIS)

    Peikari, Mohammad; Chen, Thomas Kuriran; Lasso, Anras; Heffter, Tamas; Fichtinger, Gabor; Burdette, Everette C.

    2012-01-01

    Purpose: Ultrasound elevation beamwidth leads to image artifacts and uncertainties in localizing objects (such as a surgical needle) in ultrasound images. The authors examined the clinical significance of errors caused by elevation beamwidth artifacts and imaging parameters in needle insertion procedures. Methods: Beveled prostate brachytherapy needles were inserted through all holes of a grid template under real-time transrectal ultrasound (TRUS) guidance. The needle tip position as indicated by the TRUS image was compared to their observed physical location. A new device was developed to measure the ultrasound elevation beamwidth. Results: Imaging parameters of the TRUS scanner have direct impact on the localization error ranging from 0.5 up to 4 mm. The smallest localization error was observed laterally close to the center of the grid template and axially within the beam's focal zone. Largest localization error occurs laterally around both sides of the grid template and axially within the beam's far field. The authors also found that the localization errors vary with both lateral and elevation offsets. Conclusions: The authors found properly adjusting the TRUS imaging settings to lower the ultrasound gain and power effectively minimized the appearance of elevation beamwidth artifacts and in turn reduced the localization errors of the needle tip.

  14. Recommendations for cask features for robotic handling from the Advanced Handling Technology Project

    International Nuclear Information System (INIS)

    Drotning, W.

    1991-02-01

    This report describes the current status and recent progress in the Advanced Handling Technology Project (AHTP) initiated to explore the use of advanced robotic systems and handling technologies to perform automated cask handling operations at radioactive waste handling facilities, and to provide guidance to cask designers on the impact of robotic handling on cask design. Current AHTP tasks have developed system mock-ups to investigate robotic manipulation of impact limiters and cask tiedowns. In addition, cask uprighting and transport, using computer control of a bridge crane and robot, were performed to demonstrate the high speed cask transport operation possible under computer control. All of the current AHTP tasks involving manipulation of impact limiters and tiedowns require robotic operations using a torque wrench. To perform these operations, a pneumatic torque wrench and control system were integrated into the tool suite and control architecture of the gantry robot. The use of captured fasteners is briefly discussed as an area where alternative cask design preferences have resulted from the influence of guidance for robotic handling vs traditional operations experience. Specific robotic handling experiences with these system mock-ups highlight a number of continually recurring design principles: (1) robotic handling feasibility is improved by mechanical designs which emphasize operation with limited dexterity in constrained workspaces; (2) clearances, tolerances, and chamfers must allow for operations under actual conditions with consideration for misalignment and imprecise fixturing; (3) successful robotic handling is enhanced by including design detail in representations for model-based control; (4) robotic handling and overall quality assurance are improved by designs which eliminate the use of loose, disassembled parts. 8 refs., 15 figs

  15. Irritant contact dermatitis caused by needle-like calcium oxalate crystals, raphides, in Agave tequilana among workers in tequila distilleries and agave plantations.

    Science.gov (United States)

    Salinas, M L; Ogura, T; Soffchi, L

    2001-02-01

    It was found that needle-like calcium oxalate crystals, raphides, are found abundantly in all tissues of Agave tequilana plants; thus, 1 droplet (0.03 ml) of juice pressed from leaves contains 100-150 crystals, 30-500 microm in length, sharpened at both ends. In tequila distilleries, 5/6 of the workers who handle the agave stems have experienced the characteristic irritation. In contrast, only 1/3 of workers in agave plantations who harvest agave plants, complain of the irritation. It is confirmed that all the irritation suffered in both distilleries and plantations takes place at bodily locations where the plants come into contact with the worker's skin in the course of their work.

  16. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  17. Toward improving fine needle aspiration cytology by applying Raman microspectroscopy

    Science.gov (United States)

    Becker-Putsche, Melanie; Bocklitz, Thomas; Clement, Joachim; Rösch, Petra; Popp, Jürgen

    2013-04-01

    Medical diagnosis of biopsies performed by fine needle aspiration has to be very reliable. Therefore, pathologists/cytologists need additional biochemical information on single cancer cells for an accurate diagnosis. Accordingly, we applied three different classification models for discriminating various features of six breast cancer cell lines by analyzing Raman microspectroscopic data. The statistical evaluations are implemented by linear discriminant analysis (LDA) and support vector machines (SVM). For the first model, a total of 61,580 Raman spectra from 110 single cells are discriminated at the cell-line level with an accuracy of 99.52% using an SVM. The LDA classification based on Raman data achieved an accuracy of 94.04% by discriminating cell lines by their origin (solid tumor versus pleural effusion). In the third model, Raman cell spectra are classified by their cancer subtypes. LDA results show an accuracy of 97.45% and specificities of 97.78%, 99.11%, and 98.97% for the subtypes basal-like, HER2+/ER-, and luminal, respectively. These subtypes are confirmed by gene expression patterns, which are important prognostic features in diagnosis. This work shows the applicability of Raman spectroscopy and statistical data handling in analyzing cancer-relevant biochemical information for advanced medical diagnosis on the single-cell level.

  18. Impact of local anaesthetics and needle calibres used for painless PRP injections on platelet functionality.

    Science.gov (United States)

    Bausset, Olivier; Magalon, Jeremy; Giraudo, Laurent; Louis, Marie-Laure; Serratrice, Nicolas; Frere, Corrine; Magalon, Guy; Dignat-George, Françoise; Sabatier, Florence

    2014-01-01

    The platelet-rich plasma (PRP) is an autologous biotherapy commonly used for its healing properties. Once activated, platelets released a real "cocktail" of growth factor and cytokines implied in numerous regenerative processes. However the impact of medical practices associated to PRP therapeutic use on platelets functionality remains poorly known. we evaluated the in vitro effects of two commonly used local anesthetics (Xylocaine(*) and Naropin(*)) on PRP functionality. We also investigated the quantity and quality of PRP that passed through the smallest gauge needle commercialized. PRP from 9 healthy volunteers were prepared using our previously described home made purification protocol. Platelet aggregation capacity was evaluated by aggregometry assays and the growth factor release was determined by ELISA after platelet activation. We also evaluated the platelet activation status, reactivity and stability of platelets by flow cytometry using the P-selectin expression marker. the association of local anaesthetics with PRP injections resulted in a significant decrease of platelets functionality, assessed by their capacity of aggregating. Local anaesthetics did not interfere with the growth factor release. The different needle sizes and calibres tested for PRP injections did not influence the platelet functionality. the use of local anaesthetics to prevent pain during PRP injections could compromise the therapeutic potential of PRP. These results suggest using carefully local anaesthetics or limiting their use as often is possible. To minimize injection pain, we recommend using 30 G needles. These data will lead to clinical recommendations for painless and controlled PRP injections.

  19. Serum Chrome levels sampled with steel needle vs. plastic IV cannula

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Overgaard, Søren

    2010-01-01

    . This study aimed to test that theory. Method: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. Results: We found statistically significant chromium contamination from the steel needle with mean differences......  Modern Metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby causing bias...... between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline significant...

  20. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery

    Science.gov (United States)

    Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.

    2017-03-01

    Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.

  1. Improvements to the Processing and Characterization of Needled Composite Laminates

    Science.gov (United States)

    2014-01-01

    the automated processing equipment are shown and discussed. The modifications allow better spatial control at the penetration sites and the ability... automated processing equipment are shown and discussed. The modifications allow better spatial control at the penetration sites and the ability to...semi- automated processing equipment, commercial off-the-shelf (COTS) needles and COTS aramid mat designed for other applications. Needled material

  2. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  3. Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images

    Science.gov (United States)

    Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600

  4. Chondromalacia patellae treated by warming needle and rehabilitation training.

    Science.gov (United States)

    Qiu, Ling; Zhang, Min; Zhang, Ji; Gao, Le-Nv; Chen, Da-wei; Liu, Jun; She, Jia-yi; Wang, Ling; Yu, Jin-yan; Huang, Le-ping; Bai, Yang

    2009-06-01

    To observe the effect of warming needle combined with rehabilitation training on chondromalacia patellae in a randomized controlled trial. The 92 cases were randomly divided into a treatment group treated by warming needle plus rehabilitation training (47 cases) and a control group treated by medication plus rehabilitation training (45 cases), and the therapeutic effect was compared after 20 sessions. The pain was relieved more obviously in the treatment group than in the control group (P chondromalacia patellae.

  5. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  6. Presenting hydrothorax predicts failure of needle aspiration in primary spontaneous pneumothorax.

    Science.gov (United States)

    Wu, Kwok Kei; Lui, Chun Tat; Ho, Chik Leung; Tsui, Kwok Leung; Fung, Hin Tat

    2016-06-01

    The objective was to evaluate if existence of hydrothorax in initial chest radiograph predicts treatment outcome in patients with primary spontaneous pneumothorax who received needle thoracostomy. This is a retrospective cohort study carried out from January 2011 to August 2014 in 1 public hospital in Hong Kong. All consecutive adult patients aged 18years or above who attended the emergency department with the diagnosis of primary spontaneous pneumothorax with needle aspiration performed as primary treatment were included. Age, smoking status, size of pneumothorax, previous history of pneumothorax, aspirated gas volume and presence of hydropneumothorax in initial radiograph were included in the analysis. The outcome was success or failure of the needle aspiration. Logistic regression was used to identify the predicting factors of failure of needle aspiration. There were a total of 127 patients included. Seventy-three patients (57.5%) were successfully treated with no recurrence upon discharge. Among 54 failure cases, 13 patients (10.2%) failed immediately after procedure as evident by chest radiograph and required second treatment. Forty-one patients (32.3%) failed upon subsequent chest radiographs. Multivariate logistic regression showed factors independently associated with the failure of needle aspiration, which included hydropneumothorax in the initial radiograph (odds ratio [OR]=4.47 [1.56i12.83], P=.005), previous history of pneumothorax (OR=3.92 [1.57-9.79], P=.003), and large size of pneumothorax defined as apex-to-cupola distance ≥5cm (OR=2.75 [1.21-6.26], P=.016). Hydropneumothorax, previous history of pneumothorax, and large size were independent predictors of failure of needle aspiration in treatment of primary spontaneous pneumothorax. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Barriers and Facilitators to Safe Food Handling among Consumers: A Systematic Review and Thematic Synthesis of Qualitative Research Studies.

    Directory of Open Access Journals (Sweden)

    Ian Young

    Full Text Available Foodborne illness has a substantial health and economic burden on society, and most cases are believed to be due to unsafe food handling practices at home. Several qualitative research studies have been conducted to investigate consumers' perspectives, opinions, and experiences with safe food handling at home, and these studies provide insights into the underlying barriers and facilitators affecting their safe food handling behaviours. We conducted a systematic review of previously published qualitative studies in this area to synthesize the main across-study themes and to develop recommendations for future consumer interventions and research. The review was conducted using the following steps: comprehensive search strategy; relevance screening of abstracts; relevance confirmation of articles; study quality assessment; thematic synthesis of the results; and quality-of-evidence assessment. A total of 39 relevant articles reporting on 37 unique qualitative studies were identified. Twenty-one barriers and 10 facilitators to safe food handling were identified, grouped across six descriptive themes: confidence and perceived risk; knowledge-behaviour gap; habits and heuristics; practical and lifestyle constraints; food preferences; and societal and social influences. Our overall confidence that each barrier and facilitator represents the phenomenon of interest was rated as high (n = 11, moderate (11, and low (9. Overarching analytical themes included: 1 safe food handling behaviours occur as part of a complex interaction of everyday consumer practices and habituation; 2 most consumers are not concerned about food safety and are generally not motivated to change their behaviours based on new knowledge about food safety risks; and 3 consumers are amenable to changing their safe food handling habits through relevant social pressures. Key implications and recommendations for research, policy and practice are discussed.

  8. Barriers and Facilitators to Safe Food Handling among Consumers: A Systematic Review and Thematic Synthesis of Qualitative Research Studies

    Science.gov (United States)

    Young, Ian; Waddell, Lisa

    2016-01-01

    Foodborne illness has a substantial health and economic burden on society, and most cases are believed to be due to unsafe food handling practices at home. Several qualitative research studies have been conducted to investigate consumers’ perspectives, opinions, and experiences with safe food handling at home, and these studies provide insights into the underlying barriers and facilitators affecting their safe food handling behaviours. We conducted a systematic review of previously published qualitative studies in this area to synthesize the main across-study themes and to develop recommendations for future consumer interventions and research. The review was conducted using the following steps: comprehensive search strategy; relevance screening of abstracts; relevance confirmation of articles; study quality assessment; thematic synthesis of the results; and quality-of-evidence assessment. A total of 39 relevant articles reporting on 37 unique qualitative studies were identified. Twenty-one barriers and 10 facilitators to safe food handling were identified, grouped across six descriptive themes: confidence and perceived risk; knowledge-behaviour gap; habits and heuristics; practical and lifestyle constraints; food preferences; and societal and social influences. Our overall confidence that each barrier and facilitator represents the phenomenon of interest was rated as high (n = 11), moderate (11), and low (9). Overarching analytical themes included: 1) safe food handling behaviours occur as part of a complex interaction of everyday consumer practices and habituation; 2) most consumers are not concerned about food safety and are generally not motivated to change their behaviours based on new knowledge about food safety risks; and 3) consumers are amenable to changing their safe food handling habits through relevant social pressures. Key implications and recommendations for research, policy and practice are discussed. PMID:27907161

  9. Multi hollow needle to plate plasmachemical reactor for pollutant decomposition

    International Nuclear Information System (INIS)

    Pekarek, S.; Kriha, V.; Viden, I.; Pospisil, M.

    2001-01-01

    Modification of the classical multipin to plate plasmachemical reactor for pollutant decomposition is proposed in this paper. In this modified reactor a mixture of air and pollutant flows through the needles, contrary to the classical reactor where a mixture of air and pollutant flows around the pins or through the channel plus through the hollow needles. We give the results of comparison of toluene decomposition efficiency for (a) a reactor with the main stream of a mixture through the channel around the needles and a small flow rate through the needles and (b) a modified reactor. It was found that for similar flow rates and similar energy deposition, the decomposition efficiency of toluene was increased more than six times in the modified reactor. This new modified reactor was also experimentally tested for the decomposition of volatile hydrocarbons from gasoline distillation range. An average efficiency of VOC decomposition of about 25% was reached. However, significant differences in the decomposition of various hydrocarbon types were observed. The best results were obtained for the decomposition of olefins (reaching 90%) and methyl-tert-butyl ether (about 50%). Moreover, the number of carbon atoms in the molecule affects the quality of VOC decomposition. (author)

  10. Performance of combined clinical mammography and needle biopsy: a nationwide study from Denmark

    DEFF Research Database (Denmark)

    Jensen, Allan; Rank, Fritz; Dyreborg, Uffe

    2006-01-01

    Clinical mammography and needle biopsy are key tools for non-operative assessment of breast lesions. We evaluated the performance of all combined tests undertaken in Denmark in 2000. Clinical mammography and needle biopsy data were collected and linked to final cancer outcome, to determine sensit...... with a suspicious or malignant result indicated a high risk of cancer, and excisional diagnostic biopsy therefore still has an important role to play.......Clinical mammography and needle biopsy are key tools for non-operative assessment of breast lesions. We evaluated the performance of all combined tests undertaken in Denmark in 2000. Clinical mammography and needle biopsy data were collected and linked to final cancer outcome, to determine...

  11. How to handle station black outs

    Energy Technology Data Exchange (ETDEWEB)

    Reisch, Frigyes [Swedish Nuclear Power Inspectorate, S-10252 Stockholm (Sweden)

    1986-02-15

    Station black out is defined as the loss of ail high voltage alternating current at a nuclear power site. An international study was made to survey the practices in the different countries. The best way to handle station black out is to avoid it therefore briefly the normal off site and emergency on site power supplies are discussed. The ways in use to enhance nuclear power plants using Boiling Water Reactors or Pressurized Water Reactors to cope with a station black out are discussed in some detail. (author)

  12. How to handle station black outs

    International Nuclear Information System (INIS)

    Reisch, Frigyes

    1986-01-01

    Station black out is defined as the loss of ail high voltage alternating current at a nuclear power site. An international study was made to survey the practices in the different countries. The best way to handle station black out is to avoid it therefore briefly the normal off site and emergency on site power supplies are discussed. The ways in use to enhance nuclear power plants using Boiling Water Reactors or Pressurized Water Reactors to cope with a station black out are discussed in some detail. (author)

  13. Mechanics of anesthetic needle penetration into human sciatic nerve.

    Science.gov (United States)

    Pichamuthu, Joseph E; Maiti, Spandan; Gan, Maria G; Verdecchia, Nicole M; Orebaugh, Steven L; Vorp, David A

    2018-06-06

    Nerve blocks are frequently performed by anesthesiologists to control pain. For sciatic nerve blocks, the optimal placement of the needle tip between its paraneural sheath and epineurial covering is challenging, even under ultrasound guidance, and frequently results in nerve puncture. We performed needle penetration tests on cadaveric isolated paraneural sheath (IPS), isolated nerve (IN), and the nerve with overlying paraneural sheath (NPS), and quantified puncture force requirement and fracture toughness of these specimens to assess their role in determining the clinical risk of nerve puncture. We found that puncture force (123 ± 17 mN) and fracture toughness (45.48 ± 9.72 J m -2 ) of IPS was significantly lower than those for NPS (1440 ± 161 mN and 1317.46 ± 212.45 Jm -2 , respectively), suggesting that it is not possible to push the tip of the block needle through the paraneural sheath only, without pushing it into the nerve directly, when the sheath is lying directly over the nerve. Results of this study provide a physical basis for tangential placement of the needle as the ideal situation for local anesthetic deposition, as it allows for the penetration of the sheath along the edge of the nerve without entering the epineurium. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Laparoscopic removal of a needle from the pancreas

    Directory of Open Access Journals (Sweden)

    Amit Jain

    2013-01-01

    Full Text Available Foreign bodies inside the pancreas are rare and usually occur after the ingestion of sharp objects like fish bone, sewing needle and toothpick. Most of the ingested foreign bodies pass spontaneously through the anus without being noticed but about 1% of them can perforate through the wall of stomach or duodenum to reach solid organs like pancreas or liver. Once inside the pancreas they can produce complications like abscess, pseudoaneurysm or pancreatits. Foreign bodies of pancreas should be removed by endoscopic or surgical methods. We hereby report our experience of successful removal one a sewing needle from pancreas.

  15. Hematoma formation during breast core needle biopsy in women taking antithrombotic therapy.

    Science.gov (United States)

    Chetlen, Alison L; Kasales, Claudia; Mack, Julie; Schetter, Susann; Zhu, Junjia

    2013-07-01

    The purpose of this study was to compare hematoma formation after breast core needle biopsy performed on patients undergoing and those not undergoing concurrent antithrombotic therapy. A prospective assessment of core needle biopsies (stereotactic, ultrasound guided, or MRI guided) performed on patients enrolled between September 2011 and July 2012 formed the basis of this study. Postprocedure mediolateral and craniocaudal mammograms were evaluated for the presence and size of hematomas. Patients were clinically evaluated for complications 24-48 hours after the procedure through telephone call or face-to-face consultation. Needle size, type of biopsy, and presence of hematoma and documented complications were correlated with use of antithrombotic agents (including aspirin, warfarin, clopidogrel, and daily nonsteroidal antiinflammatory medications). No clinically significant hematomas or bleeding complications were found. Eighty-nine of 617 (14.4%) non-clinically significant hematomas were detected on postprocedure mammograms. The probability of development of a non-clinically significant hematoma was 21.6% for patients taking antithrombotics and 13.0% for those not taking antithrombotics. Concurrent antithrombotic therapy and larger needle gauge were significant factors contributing to the probability of hematoma formation. The volume of the hematoma was not related to needle gauge or presence of antithrombotic therapy. No clinically significant hematomas were found. Because there are potential life-threatening risks to stopping antithrombotic therapy before breast biopsy, withholding antithrombotic therapy for core needle breast biopsy is not recommended because the incidence of non-clinically significant hematoma is low.

  16. Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking.

    Science.gov (United States)

    Kim, Jun Sik; Park, Young Ji; Lee, Yoon Jung; Kim, Nam Gyun; Lee, Kyung Suk

    2016-12-01

    Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.

  17. Systematic review of long-term Xingnao Kaiqiao needling effcacy in ischemic stroke treatment

    Directory of Open Access Journals (Sweden)

    Zhi-xin Yang

    2015-01-01

    CONCLUSION: The Xingnao Kaiqiao needling method has a better effect than control treatment in reducing disability rate. The long-term effect of Xingnao Kaiqiao needling against ischemic stroke is better than that of control treatment. However, the limitations of this study limit the strength of the conclusions. Randomized controlled trials with a strict, reasonable design, and multi-center, large-scale samples and follow-up are necessary to draw conclusions about Xingnao Kaiqiao needling.

  18. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  19. Effect of body condition on consumption of pine needles (Pinus ponderosa) by beef cows.

    Science.gov (United States)

    Pfister, J A; Panter, K E; Gardner, D R; Cook, D; Welch, K D

    2008-12-01

    We determined whether cows in low (LBC) or high body condition (HBC) would consume different amounts of green pine needles (Pinus ponderosa). Cows (mature; open Hereford and Hereford x Angus) were fed a maintenance basal diet (alfalfa pellets) for Exp. 1 and 2; during Exp. 3 and 4, cows were fed high-protein and high-energy diets, respectively. Experiment 5 was a grazing study on rangeland during winter in South Dakota; diets were determined by using bite counts. Mean BCS (1 = emaciated, 9 = obese) was 7.5 for HBC cows and <4.0 for LBC cows during the experiments. During Exp. 1, LBC cows consumed more (P = 0.001) pine needles than did HBC cows (5.5 +/- 0.25 vs. 1.0 +/- 0.14 g/kg of BW daily, respectively). During Exp. 2, there was a day x treatment interaction (P = 0.001) as LBC cows consumed variable, but greater, amounts of pine needles than did HBC cows (3.7 +/- 0.19 vs. 1.3 +/- 0.12 g/kg of BW daily, respectively). When fed a high-protein/low-energy diet, LBC cows ate more (P = 0.04) pine needles than did HBC cows. When fed a low-protein/high-energy diet, there was a day x treatment interaction (P = 0.001) because LBC cows consumed more pine needles than did HBC cows for the first 3 d of the study, and then consumption by LBC animals decreased during the last 4 d. These experiments suggest that the protein:energy ratio may be an important factor in the ability of cows to tolerate terpenes, and that cows were not able to sustain an increased quantity of needle consumption on a low-protein diet. During the 25-d grazing study, there was a day x treatment interaction (P = 0.001) as LBC animals selected more pine needles (up to 25% of daily bites) on some days compared with HBC cows. Weather influenced pine needle consumption because pine needle bites by LBC cows were related (r(2) = 0.60; P = 0.001) to days of greater snow depth and lower minimum daily temperatures. Both LBC and HBC cows increased selection of pine needles from trees during cold, snowy weather, but

  20. Changes in the rumen bacterial microbiome of cattle exposed to ponderosa pine needles.

    Science.gov (United States)

    Welch, K D; Stonecipher, C A; Gardner, D R; Cook, D; Pfister, J A

    2017-05-01

    Consumption of ponderosa pine needles, as well as needles and bark from a number of other trees, can cause abortions in cattle. The abortifacient compounds in these trees are labdane resin acids, including isocupressic acid and agathic acid. Previous research has demonstrated that cattle conditioned to pine needles metabolize the labdane resin acids more quickly than naïve cattle. The results from that study indicated that changes had occurred in the rumen of conditioned cattle. Therefore, in this study, the changes that occurred in the rumen bacterial microflora of cattle during exposure to ponderosa pine needles were evaluated. Cattle were dosed with ground pine needles twice daily for 7 d. Rumen samples were collected on d 0, 3, 7, and 14 (7 d after treatment stopped) and ruminal bacterial microbiome analyses were performed. There were 372 different genera of bacteria identified in the rumen samples. Principal coordinate analysis indicated that there was a significant difference in the rumen bacterial composition between the time points. There were 18 genera that increased in abundance from d 0 to d 7. Twenty three genera decreased in abundance from d 0 to d 7. The results from this study demonstrated that exposure of cattle to pine needles caused a clear shift in the rumen microbiome composition. In general, this shift lasted less than 1 wk post exposure, which indicates that any prophylactic treatment to manipulate the ruminal metabolism of the abortifacient compounds in pine needles would need to be continuously administered to maintain the necessary microbial composition in the rumen.

  1. A major trade-off between structural and photosynthetic investments operative across plant and needle ages in three Mediterranean pines.

    Science.gov (United States)

    Kuusk, Vivian; Niinemets, Ülo; Valladares, Fernando

    2018-04-01

    Pine (Pinus) species exhibit extensive variation in needle shape and size between juvenile (primary) and adult (secondary) needles (heteroblasty), but few studies have quantified the changes in needle morphological, anatomical and chemical traits upon juvenile-to-adult transition. Mediterranean pines keep juvenile needles longer than most other pines, implying that juvenile needles play a particularly significant role in seedling and sapling establishment in this environment. We studied needle anatomical, morphological and chemical characteristics in juvenile and different-aged adult needles in Mediterranean pines Pinus halepensis Mill., Pinus pinea L. and Pinus nigra J. F. Arnold subsp. salzmannii (Dunal) Franco hypothesizing that needle anatomical modifications upon juvenile-to-adult transition lead to a trade-off between investments in support and photosynthetic tissues, and that analogous changes occur with needle aging albeit to a lower degree. Compared with adult needles, juvenile needles of all species were narrower with 1.6- to 2.4-fold lower leaf dry mass per unit area, and had ~1.4-fold thinner cell walls, but needle nitrogen content per dry mass was similar among plant ages. Juvenile needles also had ~1.5-fold greater mesophyll volume fraction, ~3-fold greater chloroplast volume fraction and ~1.7-fold greater chloroplast exposed to mesophyll exposed surface area ratio, suggesting overall greater photosynthetic activity. Changes in needle traits were similar in aging adult needles, but the magnitude was generally less than the changes upon juvenile to adult transition. In adult needles, the fraction in support tissues scaled positively with known ranking of species tolerance of drought (P. halepensis > P. pinea > P. nigra). Across all species, and needle and plant ages, a negative correlation between volume fractions of mesophyll and structural tissues was observed, manifesting a trade-off between biomass investments in different needle functions. These

  2. The FMEA Analysis for Fuel Handling System at Cernavoda Unit 2

    International Nuclear Information System (INIS)

    Park, Jin Hee; Kim, Tae Woon; Rhee, Bo Wook; Yoon, Chul; Kim, Hyeong Tae; Cho, In Gil; Kim, Seong Ho

    2006-01-01

    A Nuclear Safety Evaluation was performed by an independent assessor at the request of the regulatory authority CNCAN (Comisia Nationala pentru Controlul Activitatilor Nucleare. National Committee for Nuclear Activities Control in Romania) to provide an independent overview of all the nuclear safety aspects of Cernavoda Unit 2 under construction and an expert opinion whether the completed Cernavoda Unit-2 Nuclear Power Plant would satisfy current Western European nuclear safety objectives and practices. A report was produced (Cernavoda 2 Nuclear Safety Expert Project, 'Task 10 . Safety Evaluation Report', A.F.Parsons, NNC Limited, December 2001) and contains recommendations either mandatory or advisory. The FMEA study, one of the mandatory recommendations, is performing now for fuel handling system and radioactive waste handling system for Cernavoda unit 2 in Romania sponsored by KHNP. In this paper, only the FMEA study for fuel handling system is presented

  3. [Exploration of acupoint combination and needling techniques in the reinforcing and reducing manipulation at different acupoints].

    Science.gov (United States)

    Dai, Qing; Sheng, Xiesun; Chen, Feng

    2017-04-12

    The reinforcing and reducing manipulation at different acupoints is a kind of acupuncture manipulations and has satisfactory clinical therapeutic effects, combined with a proper needling techniques. The reinforcing needling method is used in the upper and the reducing one in the lower, the distal acupoints are combined with the nearby acupoints. The local acupoints or adjcant acupoints of the affected area are regarded as the nearby acupoints, e.g. the acupoints in the upper. The distant acupoints and the acupoints on the hand and foot are named as distal acupoints, e.g. the acupoint in the lower. In the reinforcing manipulation, the needle is inserted shallowly along the running direction of meridian. In the reducing manipulation, the needle is inserted deeply and against the running direction of meridian. The yin - yang couple needling technique is used with the combination of the front- mu and back- shu points. In the first option, the reinforcing and reducing needling method with rotating technique is predominated at the front- mu points, while that with lifting and thrusting technique is at the back- shu points. In the second option, when needling the back- shu points, the needling sensation is transmitted along the transverse segment and far to the chest and abdomen. These two kinds of integration of acupoint combination and needling techniques display a certain clinical significance in improving the therapeutic effects of acupuncture.

  4. Open magnetic resonance imaging using titanium-zirconium needles: improved accuracy for interstitial brachytherapy implants?

    International Nuclear Information System (INIS)

    Popowski, Youri; Hiltbrand, Emile; Joliat, Dominique; Rouzaud, Michel

    2000-01-01

    Purpose: To evaluate the benefit of using an open magnetic resonance (MR) machine and new MR-compatible needles to improve the accuracy of brachytherapy implants in pelvic tumors. Methods and Materials: The open MR machine, foreseen for interventional procedures, allows direct visualization of the pelvic structures that are to be implanted. For that purpose, we have developed MR- and CT-compatible titanium-zirconium (Ti-Zr) brachytherapy needles that allow implantations to be carried out under the magnetic field. In order to test the technical feasibility of this new approach, stainless steel (SS) and Ti-Zr needles were first compared in a tissue-equivalent phantom. In a second step, two patients implanted with Ti-Zr needles in the brachytherapy operating room were scanned in the open MR machine. In a third phase, four patients were implanted directly under open MR control. Results: The artifacts induced by both materials were significantly different, strongly favoring the Ti-Zr needles. The implantation in both first patients confirmed the excellent quality of the pictures obtained with the needles in vivo and showed suboptimal implant geometry in both patients. In the next 4 patients, the tumor could be punctured with excellent accuracy, and the adjacent structures could be easily avoided. Conclusion: We conclude that open MR using MR-compatible needles is a very promising tool in brachytherapy, especially for pelvic tumors

  5. Health physics considerations in UF{sub 6} handling

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.C. [Norway Assoicates, Inc., Oak Ridge, TN (United States)

    1991-12-31

    Uranium is a radioactive substance that emits alpha particles and very small amounts of gamma radiation. Its daughter products emit beta and gamma radiation. In uranium handling operations these are the radiations one must consider. This presentation will review the characteristics of the radiations, the isotopes from which they originate, the growth and decay of the uranium daughter products, and some specific health physics practices dictated by these factors.

  6. Fine-needle trucut biopsy versus fine-needle aspiration cytology with ultrasound guidance in the abdomen

    International Nuclear Information System (INIS)

    O'Connell, A.M.; Keeling, F.; Given, M.; Logan, M.; Lee, M.J.

    2008-01-01

    Historically, fine-needle aspiration cytology (FNAC) has varying sensitivity, specificity and accuracy in the diagnosis of abdominal lesions with a high insufficient sampling rate. We compared 20-G fine-needle trucut biopsy (FNTB) with FNAC results in the biopsy of solid abdominal tumours. A retrospective review of 171 (128x 20-G FNTB and 43x FNAC) ultrasound-guided biopsies of abdominal tumours on 157 patients (male : female 85:72, mean age 61.25 years) were carried out. One hundred and seventy-one biopsies were carried out: liver 109, pancreas 19, lumph node 10, omentum 5, right iliac fossa mass 6, adrenal 6 and others 16. An average of 2.06 and 1.97 passes (range 1-4) were carried out per FNTB and FNAC, respectively. A definitive diagnosis was made in 122/128 biopsies (95.3%) and 32/43 biopsies (74.4%) for FNTB and FNAC, respectively. Diagnoses consisted of metastatic liver disease (74/171), pancreatic adenocarcinoma (10/171), lymphoma (8/171) and others (33/171) and benign (29/171). No significant complications occurred in either group. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87, 100, 100, 50, 84.4 and 93.1, 100, 100, 60, 71.4 for FNTB and FNAC, respectively. A greater and more consistent positive diagnosis rate is yielded by 20-G FNTB (95.3%) that FNAC (74.4%). The diagnostic accuracy of FNTB is 84.4% cmopared with 69.8% for FNAC. A greater insufficient sampling rate occurs with FNAC (25.6%) than with FNTB (4.7%). For abdominal biopsy, 20-G FNTB needles have a much higher yield than FNAC with no increase in complications. FNTB is the preferred choice, particularly where cytological assistance at the time of biopsy is unavailable.

  7. Development of first full scope commercial CANDU-6 fuel handling simulator

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, W., E-mail: BCrawford@atlanticnuclear.ca [Atlantic Nuclear Services Inc., Fredericton, NB (Canada); McInerney, J. M., E-mail: JMcInerney@nbpower.com [Point Lepreau Generating Station, Maces Bay, NB (Canada); Moran, E.S.; Nice, J. W.; Sinclair, D.M.; Somerville, S.; Usalp, E.C.; Usalp, M., E-mail: EMoran@atlanticnuclear.ca, E-mail: JNice@atlanticnuclear.ca, E-mail: DSinclair@atlanticnuclear.ca, E-mail: SSomerville@atlanticnuclear.ca, E-mail: ECUsalp@atlanticnuclear.ca, E-mail: MUsalp@atlanticnuclear.ca [Atlantic Nuclear Services Inc., Fredericton, NB (Canada)

    2015-07-01

    Unique to CANDU reactors is continuous on-power refueling. In the CANDU-6 design, the fuel bundles are contained within 380 pressure tubes. Fuelling machines, one on either side of the reactor face move on a bridge and carriage system to the appointed channel and fuel under computer control. The fuelling machine is an immensely complicated mechanical device. None of the original Canadian full scope simulators incorporated the interaction of the fuel handling system. Traditionally, the final stages of Fuel Handling Operator qualification utilizes on the job training in a production environment carried out in the station main control room. For the purpose of supporting continual improvement in fuel handling training at the Third Qinshan Nuclear Plant Company (TQNPC), Atlantic Nuclear Services in a joint project with New Brunswick Power, developed the first commercial full scope CANDU-6 Fuel Handling simulator, integrated into the existing TQNPC Full Scope Simulator framework. The TQNPC Fuel Handling simulator is capable of supporting all normal on-power and off-power refuelling procedures as well as other abnormal operating conditions, which will allow training to be conducted, based on the plant specific operating procedures. This paper will discuss its development, the importance of this tool and its advantages over past training practices. (author)

  8. Development of first full scope commercial CANDU-6 fuel handling simulator

    International Nuclear Information System (INIS)

    Crawford, W.; McInerney, J. M.; Moran, E.S.; Nice, J. W.; Sinclair, D.M.; Somerville, S.; Usalp, E.C.; Usalp, M.

    2015-01-01

    Unique to CANDU reactors is continuous on-power refueling. In the CANDU-6 design, the fuel bundles are contained within 380 pressure tubes. Fuelling machines, one on either side of the reactor face move on a bridge and carriage system to the appointed channel and fuel under computer control. The fuelling machine is an immensely complicated mechanical device. None of the original Canadian full scope simulators incorporated the interaction of the fuel handling system. Traditionally, the final stages of Fuel Handling Operator qualification utilizes on the job training in a production environment carried out in the station main control room. For the purpose of supporting continual improvement in fuel handling training at the Third Qinshan Nuclear Plant Company (TQNPC), Atlantic Nuclear Services in a joint project with New Brunswick Power, developed the first commercial full scope CANDU-6 Fuel Handling simulator, integrated into the existing TQNPC Full Scope Simulator framework. The TQNPC Fuel Handling simulator is capable of supporting all normal on-power and off-power refuelling procedures as well as other abnormal operating conditions, which will allow training to be conducted, based on the plant specific operating procedures. This paper will discuss its development, the importance of this tool and its advantages over past training practices. (author)

  9. Analysis of Handling Processes of Record Versions in NoSQL Databases

    Directory of Open Access Journals (Sweden)

    Yu. A. Grigorev

    2015-01-01

    its right bound of the confidence interval on the average deliberation time have a pronounced maximum. In the same variant an average handling time of record versions practically does not depend on the average deliberation time, but the right bound of the confidence interval of this time has a pronounced minimum.

  10. A spatial analysis of the physical and social environmental correlates of discarded needles.

    Science.gov (United States)

    de Montigny, Luc; Moudon, Anne Vernez; Leigh, Barbara C; Kim, Sun-Young

    2011-05-01

    The role that the urban environment plays in influencing drug users' injection and needle disposal decisions is poorly understood. We identified potential attractors and deterrents of needle discarding, and then used a geographic information system (GIS) to quantify these factors for a neighborhood in Montréal, Canada. In multivariate logistic regression, discarded needles were found to have more associations with physical factors than with social factors. Visual exposure and proximity to a single-room occupancy hotel, a pay phone, an adult service or a pawnshop were important physical environmental predictors. These findings are discussed in relation to developing public health and urban design-based harm reduction approaches to needle discarding in public space. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  12. Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil.

    Science.gov (United States)

    Pinto, Raquel Oliveira Medrado; Correia, Eliznara Fernades; Pereira, Keyla Carvalho; Costa Sobrinho, Paulo de Souza; da Silva, Daniele Ferreira

    2015-06-01

    Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets.

  13. [Administration of vaccine against myxomatosis using live MXT by means of external ear puncture with a special needle].

    Science.gov (United States)

    Cupera, Z; Krupka, V; Jiran, E

    1982-01-01

    A new application method was developed and tested for the immunoprophylaxis of rabbits against myxomatosis using a live MXT vaccine. This new application method--injection of the ear with a special double needle--is very simple and easy. Its use enables a five-fold increase in vaccination doses as compared with subcutaneous application while the amount of vaccine remains the same. In laboratory this method with the MXT vaccine secured a 98.2% protection of the vaccinated animals. One vaccination dose contains 18.1 to 37.2 PD50. Eleven months from a single vaccination by injecting the ear, 83% of the rabbits still remained protected against experimental infection. With the use of the new application method of injecting the ear with the special double needle, the live MXT vaccine against myxomatosis in rabbits represents an effective, easily practicable and economically advantageous direction in the immunoprophylaxis of rabbits against myxomatosis.

  14. [Percutaneous needle aponeurotomy for Dupuytren's disease].

    Science.gov (United States)

    Spies, C K; Müller, L P; Skouras, E; Bassemir, D; Hahn, P; Unglaub, F

    2016-02-01

    Percutaneous transverse aponeurotomy of the cord by using a hypodermic needle as a scalpel blade in order to improve function of the hand. Symptomatic flexion contracture with positive table top test caused by a single, palpable cord within the palm (primarily Tubiana stages I and II). Multiple, infiltrating or broad-based cords within the palm; irritated skin conditions; exclusive digital cord localization; recurrence after aponeurectomy; previous surgical intervention at the site of interest, digital nerve lesions; lack of patient compliance. Pinpoint surface anesthesia is obtained by injecting each portal area subdermally with 0.1 ml of local anesthetic. These applications start from distally to proximally within the palm while the most distal injection site is located proximal to the distal palm crease. Then the needle tip is introduced perpendicular to the cord. Sawing movements through the cord are performed transversely. While passively extending the contracted finger, the cord is held under tension which guarantees safe cutting. Patients are encouraged to report immediate pain sensation or numbness in order to prevent injuries to neurovascular structures and active finger flexion excludes tendon lesions during the procedure. Introducing the needle tip may be performed at several sites along the cord, if necessary, from distal to proximal at least 5 mm apart with prior pinpoint surface anesthesia. Finally, cautious passive stretching may be done after each release. Bandaging allowing immediate motion; application of a hand-based extension splint-glove during the night for 3-6 months. Recurrence rate was 53% in 15 retrospectively examined patients after a mean interval of 40 months postoperatively.

  15. Diagnostic utility of alpha-methylacyl CoA racemase (P504S) on prostate needle biopsy.

    Science.gov (United States)

    Jiang, Zhong; Woda, Bruce A

    2004-11-01

    Alpha-methylacyl CoA racemase (AMACR), also known as P504S, was identified by the analysis of cDNA library subtraction in conjunction with high throughput microarray screening from prostate tissue and has been proven to be one of the very few biomarkers that can distinguish cancer from benign cells with high sensitivity and specificity for prostate carcinoma. It is a successful example of the translation of molecular findings into clinical practice. This review focuses on the study of AMACR (P504S) expression in small focal prostate cancer and atypical small acinar proliferation (ASAP) on needle biopsies and emphasizes the utility of AMACR (P504S) in routine surgical pathology practice. We also discuss the potential pitfalls and caveats in the interpretation of immunostaining results.

  16. Cannula Versus Sharp Needle for Placement of Soft Tissue Fillers: An Observational Cadaver Study.

    Science.gov (United States)

    van Loghem, Jani A J; Humzah, Dalvi; Kerscher, Martina

    2017-12-13

    Soft-tissue fillers have become important products for facial rejuvenation. Deep fat compartments and facial bones lose volume during the natural aging process. For the most natural-looking results, deep volumetric injections at strategic sites are therefore preferred. Supraperiosteal placement is performed with a sharp needle or a non-traumatic cannula. The primary objective was to determine whether there is a difference in precision between supraperiosteal placement with a sharp needle compared with a non-traumatic cannula in cadaver specimens. A secondary objective was to analyze the safety profiles of both injection techniques. Cadaver heads were injected with dye material and soft-tissue fillers at multiple aesthetic facial sites on the supraperiosteum and subsequently dissected for observation of dye and filler placement. The non-traumatic cannula technique resulted in product being confined to the deep anatomic layers. In contrast, with the sharp needle technique, material was placed in multiple anatomic layers, from the periosteum to more superficial skin layers. For both techniques results were consistent for all facial sites. Although direct extrapolation from cadavers to the in vivo situation cannot be made, cannulae showed more precision in placement of product. With the sharp needle, the material was injected on the periosteum, and then migrated in a retrograde direction along the trajectory of the needle path, ending up in multiple anatomic layers. The sharp needle technique also showed a higher complication risk with intra-arterial injection occurring, even though the needle tip was positioned on the periosteum and the product was injected with the needle in constant contact with the periosteum. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  17. Development of a tapping device: a new needle insertion method for prostate brachytherapy

    International Nuclear Information System (INIS)

    Lagerburg, V; Moerland, M A; Konings, M K; Vosse, R E van de; Lagendijk, J J W; Battermann, J J

    2006-01-01

    The purpose of this study is to develop and test a tapping device for needle insertion for prostate brachytherapy. This device will tap the needle into the prostate with a certain, well-defined, amount of momentum, instead of the currently used method of pushing the needle. Because of the high needle insertion velocity, we expect prostate motion and deformation to be less compared to current methods. We measured the momentum that is applied when manually tapping the needle into the prostate and found a mean momentum of 0.50 ± 0.07 N s. The tapping device is pneumatically driven and we found that the delivered momentum increased linearly with the applied air pressure. The efficacy of the tapping device was tested on a piece of beef, placed on a freely moving and rotating platform. A significant correlation was found between the applied pressure and the rotation and displacement of the beef. Displacements and rotations were minimal for the highest pressure (4 bar) and amounted to only 2 mm and 6 deg., respectively. Higher air pressures will further reduce displacements and rotations

  18. Bleb needling outcomes for failed trabeculectomy blebs in Asian eyes: a 2-year follow up.

    Science.gov (United States)

    Tsai, Andrew S H; Boey, Pui Yi; Htoon, Hla M; Wong, Tina T

    2015-01-01

    To describe the outcomes of bleb needling in primary glaucoma in an Asian tertiary eye centre over a 2y period. To compare the success rates between primary angle-closure glaucoma (PACG) and primary open angle glaucoma (POAG). Lastly, to identify factors associated with success of bleb needling. This was a retrospective review of 227 patients who underwent bleb needling between June 2009 and June 2011 in Singapore National Eye Centre. The 5-fluorouracil (5-FU) augmented bleb needling was performed either at the slit lamp or in the operating theatre. Repeat bleb needlings were performed as necessary. Complete success was defined as maintenance of intraocular pressure (IOP) ≥6 mm Hg and ≤21 mm Hg, in the absence of further surgery or use of antiglaucoma medication. Qualified success met the above criteria with or without use of antiglaucoma medications. One hundred and seventy-five eyes completed the two-year follow up. Sixty-nine percent of participants had POAG and 31% had PACG. The mean interval between filtering surgery and bleb needling was 299.9±616.4d for POAG and 167.1±272.2d for PACG. Mean needling attempts were 1.9±1.4 and 2±1.6 for POAG and PACG respectively. In general, there was a statistically significant reduction of IOP ranging from 21.9% to 26.8% from month 1 through to month 24. The complete success rates at month 6 were 70.0% for POAG and 65.7% for PACG. At month 12, this decreased to 62.2% for POAG and PACG and at month 24, 57.9% for POAG and 63.0% for PACG respectively. The qualified success rates at month 6 for POAG and PACG were 23.8% and 29.9% respectively, 32.2% and 29.2% at month 12, and 34.7% and 29.6% at month 24. The success rates between POAG and PACG were not significantly different (P>0.05 for complete and qualified success at months 6, 12 and 24). An increased number of needlings and higher pre-needling IOP were associated with failure. The 5-FU augmented bleb needling within one year of trabeculectomy in Asian eyes can

  19. Bleb needling outcomes for failed trabeculectomy blebs in Asian eyes:a 2-year follow up

    Directory of Open Access Journals (Sweden)

    Andrew S. H. Tsai

    2015-08-01

    Full Text Available AIM:To describe the outcomes of bleb needling in primary glaucoma in an Asian tertiary eye centre over a 2y period. To compare the success rates between primary angle-closure glaucoma (PACG and primary open angle glaucoma (POAG. Lastly, to identify factors associated with success of bleb needling.METHODS:This was a retrospective review of 227 patients who underwent bleb needling between June 2009 and June 2011 in Singapore National Eye Centre. The 5-fluorouracil (5-FU augmented bleb needling was performed either at the slit lamp or in the operating theatre. Repeat bleb needlings were performed as necessary. Complete success was defined as maintenance of intraocular pressure (IOP ≥6 mm Hg and ≤21 mm Hg, in the absence of further surgery or use of antiglaucoma medication. Qualified success met the above criteria with or without use of antiglaucoma medications.RESULTS:One hundred and seventy-five eyes completed the two-year follow up. Sixty-nine percent of participants had POAG and 31% had PACG. The mean interval between filtering surgery and bleb needling was 299.9±616.4d for POAG and 167.1±272.2d for PACG. Mean needling attempts were 1.9±1.4 and 2±1.6 for POAG and PACG respectively. In general, there was a statistically significant reduction of IOP ranging from 21.9% to 26.8% from month 1 through to month 24. The complete success rates at month 6 were 70.0% for POAG and 65.7% for PACG. At month 12, this decreased to 62.2% for POAG and PACG and at month 24, 57.9% for POAG and 63.0% for PACG respectively. The qualified success rates at month 6 for POAG and PACG were 23.8% and 29.9% respectively, 32.2% and 29.2% at month 12, and 34.7% and 29.6% at month 24. The success rates between POAG and PACG were not significantly different (P>0.05 for complete and qualified success at months 6, 12 and 24. An increased number of needlings and higher pre-needling IOP were associated with failure.CONCLUSION:The5-FU augmented bleb needling within one year

  20. [Treatment of trigger finger with located needle knife].

    Science.gov (United States)

    Zhang, Qi-Feng; Yang, Jiang; Xi, Sheng-Hua

    2016-07-25

    To investigate the clinical effects of located needle knife in the treatment of trigger finger. The clinical data of 133 patients(145 fingers) with trigger finger underwent treatment with located needle knife from September 2010 to March 2014 were retrospectively analyzed. There were 37 males(40 fingers) and 96 females (105 fingers), aged from 18 to 71 years old with a mean of 51.8 years. Course of disease was from 1 to 19 months with an average of 8.2 months. Affected fingers included 82 thumbs, 12 index fingers, 11 middle fingers, 36 ring fingers, and 4 little fingers. According to the standard of Quinnell grade, 42 fingers were grade III, 92 fingers were grade IV, and 11 fingers were grade V. Firstly the double pipe gab was put into the distal edge of hypertrophic tendon sheath, then small knife needle was used to release the sheath proximally along the tendon line direction. The informations of wound healing and nerve injury, postoperative finger function, finger pain at 6 months were observed. The operation time was from 8 to 25 min with an average of 9.8 min. All the patients were followed up from 6 to 26 months with an average of 12.5 months. No complications such as the wound inflammation and seepage, vascular or nerve injuries were found. According to the standard of Quinnell grade, 123 fingers got excellent results, 15 good, 7 poor. It's a good choice to treat trigger finger with located needle knife in advantage of minimal invasion, simple safe operation, and it should be promoted in clinic.